QRG 23 CF Card To Upload FW Apps To 1200
QRG 23 CF Card To Upload FW Apps To 1200
QRG 23 CF Card To Upload FW Apps To 1200
To successfully load the new firmware then follow the instructions below. Be sure to
read them carefully and do exactly as described below in the given order.
Page 1 of 3
Quick Reference Guide # 23 Global Survey Limited
e. To check the firmware has correctly loaded, access the STATUS System
Information screen, Firmware page view. (Press USER and then F3
(STAT) and then choose 3 System Information).
4. Load the RX1200 controller firmware (this step is only necessary for
RX1210 and RX1220 instruments and is NOT necessary for the RX1250
Controller)
a. Upload System Files and then choose 3 Instrument Firmware. The
TOOLS Upload System Firmware screen is now visible. Ensure that the file
name RX1200.FW is visible in the Firmware prompt. If the file name is not
visible then check you have correctly copied the firmware file to the System
directory of the CF card.
b. Press F1 (CONT) to continue - a message will appear to ensure that you have
fully loaded batteries. Press F6 (YES) to begin the loading of the new
firmware to the instrument.
c. The loading process will take a few minutes. Once complete, a message will
appear to say that the instrument must be turned off. Turn off the instrument
and turn it back on the RX controller is now using the new firmware.
d. To check the firmware has correctly loaded, access the RX1200 About
screen. (Hold down the USER key for 2 seconds and then press F5
(ABOUT). To return to the main menu, press F4 (OK) and then ESC until
you see the main menu.
e. Note, if loading the new RX1200 firmware to the controller from a TPS
instrument, then before the RX1200 controller firmware can be loaded, it is
necessary to ensure that the RCS mode is activated on the TPS instrument.
f. Press shift and then the USER button to access the QUICK SET screen, here,
the RCS mode can easily be activated if necessary.
Page 2 of 3
Quick Reference Guide # 23 Global Survey Limited
d. A program file name should be visible in the Program prompt. If a file name
is not visible then check you have correctly copied the loadable application
files to the System directory of the CF card.
e. Press F1 (CONT) to load the application program. The loading process will
take a few seconds. Once complete, a message will appear asking if it is
wished to load another application.
f. Repeat steps 2 to 4 until all new applications have been loaded.
g. To check the applications have been correctly loaded, access the STATUS
System Information screen, Application page view. (Press USER and then
F3 (STAT) and then choose 3 System Information).
Page 3 of 3