PART 5 Bid Forms

SCHEDULE 7 Technical Data


SPECIFICATION E-302 Generator Transformer

Specification E-320 : Generator Transformers

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah
PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer

BIDDERS DATA SHEET : CONSORTIUM PP-WRATSILA FINLAND OY-


PT. WARTSILA INDONESIA

NAME OF BIDDER
Schedule 7.2 OPERATION AND CONSTRUCTION DATA Insert all data in tbese columns
The Bidder shall submit the following : *)
TRANSFORMER NAME :
1. Manufacturer...................................................................: B&D Transformer

2. Class and type of core.....................................................: Class A

3. Phase...............................................................................: 3

High Voltage Low Voltage


Winding Winding
4. Nominal system voltage (lini-to-line).....................(kV): 150 11

5. Transformer connections..........................(wye or delta): Wye Delta

6. Winding voltage : 150 11


a. Rated winding voltage.........................................(kV):
7. Transformer rating at full load (ONAF) as applicable at 65C
rise..................................................................(MVA): 60 60
8. Tap changer taps to be changed when transformer is on
load.....................................................................................:
a. Above rated voltage at full MVA capacity (Number of taps
and percent voltage each tap).................................: 8 x 1,25 % N/A
b. Below rated voltage at full MVA capacity (Number of taps
and percent vols each tap)......................................: 8 x 1,25 % N/A
c. Location of taps on winding.......................................: HV N/A

9. System highest voltage...........................................(kV): 170 12

10. Line basic lighting impulse insulation level (BI)


..............................................................................(kV): 750 75

11. Neutral highest voltage.........................................(kV): 17.5 N/A


12. Neutral basic impulse insulation level (BIL).......(kV): 95 N/A

BIDDERS DATA SHEET : CONSORTIUM PP-WRATSILA FINLAND OY-


Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)
Kalimantan Tengah
PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer
PT. WARTSILA INDONESIA

NAME OF BIDDER
Schedule 7.2 OPERATION AND CONSTRUCTION Insert all data in tbese columns
DATA
13. Applied potential test..................................(kV): 38 28


14. Induced potential test :
a. Line-to-neutral........................................(kV): 325 (Line to Gnd) N/A
b. Line-to-line.............................................(kV): 270 22

15. Lightning Impulse Test :


a. Full wave................................................(kV): 750 75
b. Chopped wave :
b.1 Crest.................................................(kV): 825 105
2-6 2-6

b.2 Minimum time to flash-over............(s):


16. Switching Impulse Test :
N/A N/A
N/A N/A

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah

PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer
a. Crest Voltage.........................................(kV):

b. Wave form....................................(s xs):


17. Load losses :
a. No load losses.......................................(kW): 40 40
b. Full lad losses.......................................(kW): 190 190

18. Bushing :
a. Insulation class......................................(kV): 170 36
b. Rated continuous current........................(A): 1200 3150
c. Basic impulse insulation level (BIL)....(kV): 750 170
d. Maximum design voltage to ground.....(kV): 98 36
e. Minimum creepage..............................(mm): 5270 920
f. Withstand test :
f.1 Dry (1 Minute)................................(kV): 355 70
f.2 Wet (10 Seconds)............................(kV): TBA TBA
g. Wet switching surge value...............(kV): 600 136

19. Neutral bushing :


a. Insulation class.....................................(kV): 52 N/A
b. Rated coninuous current........................(A): 1000 N/A
c. Basic impulse insulation level (BIL)......... : 250 N/A
d. Maximum design voltage to ground....(kV): 30 N/A
e. Minimum creepage.............................(mm): 1080 N/A

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah
PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer

BIDDERS DATA SHEET : CONSORTIUM PP-WRATSILA FINLAND OY-


PT. WARTSILA INDONESIA

NAME OF BIDDER
Schedule 7.2 OPERATION AND CONSTRUCTION Insert all data in tbese columns
DATA
f. Withstand test :
f.1 Dry (1 minute).....................................(kV): 95 N/A
f.2 Wet (10 seconds).................................(kV): TBA N/A

20. Air core reactance based on full load ONAF rating at TBA
65C at rated voltage tap as viewed from the high voltage
terrminals..............................(H):

21. Air core reactance based on full load ONAF rating at TBA
65C at rated voltage tap as viewed from the high voltage
terrminals..............................(H):

22. Approximate resistance at 75C (Per phase on rated TBA


voltage connection)..............................(Ohm):

23. Short circuit capability :


a. AC symmetrical rms short circuit current TBA
.........................................(Times normal)+
b. Peak asymmetrical rms short circuit current TBA
.........................................(Times normal)+

Note : + The normal alue of current is the rms value of


winding current when the winding is carrying rated
ONAF at rated voltage

TBA

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah
PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer
24. Total there-phase capacitance, low-voltage to
ground ...........................................................(s):
25. Transformer cooling equipent :
a. Number of radiators or heat exchangers..........: TBA
b. Capacity reduction with one (1) coller out of TBA
Service.......................................................(%):

26. Transformer Oil Preservation System


a. Name of oil....................................................: Nynas Nitro Lybra
b. Type of oil preservation equipment................: TBA
c. Oil drain valve :
c.1 Size...................................................(mm): TBA
d. Size of oil sampling valve......................(mm): TBA
e. Size of gas sampling vave......................(mm): TBA
f. Fault pressure device :
f.1 Manufacture..............................................: Messko/Equivalent
f.2 Type..........................................................: TBA

H.V L.V NEUTRAL


27. Bushing current transformers WTI WTI
a. Ratio.............................................................: 300 - 2 3200 -2 TBA
b. Accuracy class..............................................: 1 1 TBA

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah
PART 5 Bid Forms
SCHEDULE 7 Technical Data
SPECIFICATION E-302 Generator Transformer

28. Lightning arresters (If specified)


a. Voltage rating........................................(kV): TBA
b. Cantilever strenght at top of arresters without TBA
Damage..................................................(N):

Sch.7-E 302-1 Bangkanai GTPP/GEPP (Peaker) Stage 2 (140 MW)


Kalimantan Tengah