Applicator Sizing - Flow
Applicator Sizing - Flow
Project : Nivel
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:
TAG : ---
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Oil, Crude 48 API
State Liquid
Character Suspension Atmospheric Pressure 14.696 psi_a
Abrasivity Not abrasive Standard ASME (ANSI)
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian
Operating Conditions
minimum nominal maximum
Requested Flow 1 5 10 ton_short/d
Pressure 20 psi_g
Temperature 40 C
Density 48.039 lb/ft3
Viscosity 2.13377 cSt
Pressure (min/max) 20 20 psi_g
Temp. (min/max) 40 40 C
Vapor Pressure 0.9733 0.9733 0.9733 psi_a
Sound velocity 6 122 6 122 6 122 ft/s
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Nivel
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:
TAG : ---
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 1 5 10 ton_short/d
Velocity 0.001 0.003 0.006 ft/s
Pressure loss 0 0 0 psi
Measured error Volume*** n.a. n.a. n.a. %
Reynolds No. 136
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Warnings
1. This Flowmeter with the selected process connection is not available in the requested Category of PED. Please select an other process connection.
Messages
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Nivel
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:
TAG : ---
Timestamp: --- Review number: ---
Sales order number:
Fluid description
Solid content 5%
Medium character Suspension
Abrasivity Not abrasive
Conductivity Not conductive
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian
Calculated results
Density nom. 48.039 lb/ft3 Pressure nom. 20 psi_g
Viscosity nom. 2.13377 cSt Temperature nom. 40 C
Sound velocity nom. 6 122 ft/s
Vapor pressure nom. 0.9733 psi_a
Thermal expansion coeff. Beta P 0.001
Viscosity coefficient AL -6.637
Viscosity coefficient BL 2 233.724
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).