DM Plant
DM Plant
Important
Technical Specification
Important
1) Quality of treated water depends on Raw Water quality.
2) Raw water should be clean, cold, colorless and free from organic matters and oil.
3) The treated water is not Pyrogen free but it confirms to IS 1069/64.
4) Capacity per Regeneration depends on ionic load present in raw water.
Advantages
¾ Easy to install and operate with low cost maintenance.
¾ High capacity bead type Cation and Anion Resins are used which is remarkably stable
and has a long life
¾ Consistent treated water quality with lower cost of regenerates.
¾ Longer operating cycles.
¾ SARJAN Standard Deminerlisers are based on ion Exchange process up flow type
manually operated, ready to install, in order to get highest efficiency. Our
Deminerlisers are designed on new proven technical counter current regeneration
system. This means that water flow through the unit is counter current to the
regeneration chemical solution.
¾ SARJAN Deminerlisers are useful for Pharmaceuticals, Chemical, Electroplating,
Induction furnace and Industries which needed law TDS water for their requirement.
Technical Specification
Model DM-1000 DM-2000 DM-3000 DM-5000
Flow Rate Lts/Hr. Max 1000 2000 3000 5000
Min 100 200 300 500
Quantity of Resins in Lts. Cation 50 100 140 240
Anion 60 110 160 260
Working Pressure Kg./Cm2 Max 3.5 3.5 3.5 3.5
Min 1.5 1.5 1.5 1.5
Chemical Required/Regeneration HCL (30%
Commercial)
Lts 15 30 42 72
NaOH (98%)
Commercial
kgs 4.2 7.7 11.2 18.2
Quality of treated water Electrical
conductivity
micromoh/cm 10 10 10 10
Total Dissolved
solids in PPM 5 5 5 5
pH 7.5-8.5 7.5-8.5 7.5-8.5 7.5-8.5
Output/Regeneration in Lts.
(Based on Ionic Load of 200 PPM) 4800 8800 12800 21000