EXHIBIT A

SCOPE OF SERVICES

FOR

FINANCIAL PROJECT ID(S). 999999-1-52-01

DISTRICT [Enter District]

[Enter County Name] COUNTY


1 PURPOSE_________________________________________________________________4

2 PROJECT DESCRIPTION____________________________________________________6

3 PROJECT COMMON AND PROJECT GENERAL TASKS_________________________22

4 ROADWAY ANALYSIS_____________________________________________________31

5 ROADWAY PLANS________________________________________________________36

6a DRAINAGE ANALYSIS____________________________________________________38

6b DRAINAGE PLANS________________________________________________________41

7 UTILITIES_______________________________________________________________42

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES_______________46

9 STRUCTURES - SUMMARY AND MISCELLANEOUS TASKS AND DRAWINGS____52

10 STRUCTURES - BRIDGE DEVELOPMENT REPORT____________________________53

11 STRUCTURES - TEMPORARY BRIDGE______________________________________55

12 STRUCTURES - SHORT SPAN CONCRETE BRIDGE____________________________56

13 STRUCTURES - MEDIUM SPAN CONCRETE BRIDGE__________________________58

14 STRUCTURES - STRUCTURAL STEEL BRIDGE_______________________________61

15 STRUCTURES - SEGMENTAL CONCRETE BRIDGE____________________________64

16 STRUCTURES - MOVABLE SPAN___________________________________________68

17 STRUCTURES - RETAINING WALLS_________________________________________73

18 STRUCTURES - MISCELLANEOUS__________________________________________75

19 SIGNING AND PAVEMENT MARKING ANALYSIS_____________________________77

20 SIGNING AND PAVEMENT MARKING PLANS________________________________79

21 SIGNALIZATION ANALYSIS________________________________________________80

22 SIGNALIZATION PLANS___________________________________________________82

23 LIGHTING ANALYSIS_____________________________________________________84

24 LIGHTING PLANS_________________________________________________________87

A-2
25 LANDSCAPE ARCHITECTURE ANALYSIS___________________________________88

26 LANDSCAPE ARCHITECTURE PLANS_______________________________________90

27 SURVEY_________________________________________________________________91

28 PHOTOGRAMMETRY_____________________________________________________96

29 MAPPING________________________________________________________________99

30 TERRESTRIAL MOBILE LiDAR____________________________________________102

31 ARCHITECTURE DEVELOPMENT_________________________________________105

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE_____122

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS______________________127

34 INTELLIGENT TRANSPORTATION SYSTEMS PLANS_________________________136

35 GEOTECHNICAL________________________________________________________141

36 3D MODELING__________________________________________________________151

37 PROJECT REQUIREMENTS________________________________________________153

38 INVOICING LIMITS______________________________________________________155

A-3
SCOPE OF SERVICES FOR CONSULTING ENGINEERING SERVICES

HIGHWAY AND BRIDGE/STRUCTURAL DESIGN

This Exhibit forms an integral part of the agreement between the State of Florida Department of
Transportation (hereinafter referred to as the DEPARTMENT or FDOT) and
___________________________ (hereinafter referred to as the CONSULTANT) relative to the
transportation facility described as follows:

Financial Project ID: 000000 0 32 00

Federal Aid Project No.: 000000X [If applicable or N/A]

County Section No.: 00000

Description: SR 000 /US- / I- from __________(ft/mi) [N, S, E, W of] __________


(MP XX.XXX to [N, S, E, W of] __________(MP XX.XXX), __________ County

Bridge No(s).: 000000

Rail Road Crossing No: [List Crossings or N/A (See PPM 6.2.3)]

1 PURPOSE

The purpose of this Exhibit is to describe the scope of work and the responsibilities of the
CONSULTANT and the DEPARTMENT in connection with the design and preparation of a
complete set of construction contract documents and incidental engineering services, as
necessary, for improvements to the transportation facility described herein.

Major work mix includes: [Insert project specific work types]


Major work groups include: [Insert project specific major work group(s)]
Minor work groups include: [Insert project specific minor work group(s)]

Known alternative construction contracting methods include: [Insert alternative


contracting methods or N/A]

The general objective is for the CONSULTANT to prepare a set of contract documents
including plans, specifications, supporting engineering analysis, calculations and other
technical documents in accordance with FDOT policy, procedures and requirements. These
Contract documents will be used by the contractor to build the project and test the project
components. These Contract documents will be used by the DEPARTMENT or its
Construction Engineering Inspection (CEI) representatives for inspection and final
acceptance of the project. The CONSULTANT shall follow a systems engineering process to
ensure that all required project components are included in the development of the Contract
documents and the project can be built as designed and to specifications.

The Scope of Services establishes which items of work in the Plans Preparation Manual and

1 PURPOSE
A-4
STAGE I FPID(S): 999999-1-52-01
[DATE]

other pertinent manuals are specifically prescribed to accomplish the work included in this
contract, and also indicate which items of work will be the responsibility of the
CONSULTANT and/or the DEPARTMENT.

The CONSULTANT shall be aware that as a project is developed, certain modifications


and/or improvements to the original concepts may be required. The CONSULTANT shall
incorporate these refinements into the design and consider such refinements to be an
anticipated and integral part of the work. This shall not be a basis for any supplemental fee
request(s).

The CONSULTANT shall demonstrate good project management practices while working
on this project. These include communication with the DEPARTMENT and others as
necessary, management of time and resources, and documentation. The CONSULTANT
shall set up and maintain throughout the design of the project a contract file in accordance
with DEPARTMENT procedures. CONSULTANTs are expected to know the laws and rules
governing their professions and are expected to provide services in accordance with current
regulations, codes and ordinances and recognized standards applicable to such professional
services. The Consultant shall provide qualified technical and professional personnel to
perform to Department standards and procedures, the duties and responsibilities assigned
under the terms of this agreement. The Consultant shall minimize to the maximum extent
possible the Departments need to apply its own resources to assignments authorized by the
Department.

The DEPARTMENT will provide contract administration, management services, and


technical reviews of all work associated with the development and preparation of contract
documents, including Construction documents. The Departments technical reviews are for
high-level conformance and are not meant to be comprehensive reviews. The
CONSULTANT shall be fully responsible for all work performed and work products
developed under this Scope of Services. The DEPARTMENT may provide job-specific
information and/or functions as outlined in this contract, if favorable.

1 PURPOSE
A-5
STAGE I FPID(S): 999999-1-52-01
[DATE]

2 PROJECT DESCRIPTION

The CONSULTANT shall investigate the status of the project and become familiar with
concepts and commitments (typical sections, alignments, etc.) developed from prior studies
and/or activities. If a Preliminary Engineering Report is available from a prior or current
Project Development and Environmental (PD&E) study, the CONSULTANT shall use the
approved concepts as a basis for the design unless otherwise directed by the
DEPARTMENT.

[Add detailed project description here]

2.1 Project General and Roadway (Activities 3, 4, and 5)

Public Involvement: [Describe CAP level, number of public meetings or N/A].

Other Agency Presentations/Meetings: [List agencies and number of meetings or N/A]

Joint Project Agreements: [List number expected or N/A].

Specification Package Preparation: [List any significant effort or N/A].

Value Engineering: [Describe level of effort or N/A].

Risk Assessment Workshop: [Describe Level of effort required to support Risk


Assessment Workshop and associated meetings, number of follow up meetings
expected or N/A]

Plan Type: [Describe type of roadway plans, i.e., plan/profile, plan only, letter plans
or as directed].

Typical Section: [List number and description of typical sections, i.e., mainline:
four-lane divided urban curb and gutter, 4-foot bike lanes, 5-foot sidewalk, 3-foot
utility strip both directions; four-lane divided rural with paved shoulders, no
sidewalks each direction].

Pavement Design: [List number expected or N/A].

Pavement Type Selection Report(s): [Describe level of effort required submitted


with phase reviews or N/A]

Cross Slope: [Identify deficiencies or N/A]

Access Management Classification: [Classification number]

Transit Route Features: [Describe transit features or N/A]

Major Intersections/Interchanges: [List all intersections/interchanges that will require


additional plan sheets or N/A].

2 PROJECT DESCRIPTION
A-6
STAGE I FPID(S): 999999-1-52-01
[DATE]

Roadway Alternative Analysis: [Describe or N/A]

Level of TCP Plans: [Provide level or N/A].

Temporary Lighting: [Provide limits or N/A].

Temporary Signals: [Provide a list of locations].

Temporary Drainage: [Provide description or N/A].

Design Variations/Exceptions: [List anticipated variations/exceptions or N/A].

Back of Sidewalk Profiles: [List number of back of sidewalk profiles or as directed by


the DEPARTMENT].

Selective Clearing and Grubbing: [List number of acres of Selective Clearing and
Grubbing and/or Plant Preservation Area].

2.2 Drainage (Activities 6a and 6b)

System Type: [Describe expected systems, i.e., open, closed, ditches, ponds,
exfiltration, floodplain involvement, etc.]

[List number of stormwater management facility sites to be studied per basin].

[List number of cross drains].

2.3 Utilities Coordination (Activity 7)

The CONSULTANT is responsible to certify that all necessary arrangements for utility work
on this project have been made and will not conflict with the physical construction
schedule. The CONSULTANT should coordinate with DEPARTMENT personnel to
coordinate transmittals to Utility Companies and meet production schedules.

The CONSULTANT shall ensure FDOT standards, policies, procedures, practices, and
design criteria are followed concerning utility coordination.

The CONSULTANT may employ more than one individual or utility engineering consultant
to provide utility coordination and engineering design expertise. The CONSULTANT shall
identify a dedicated person responsible for managing all utility coordination activities. This
person shall be contractually referred to as the Utility Coordination Manager and shall be
identified in the CONSULTANT proposal. The Utility Coordination Manager shall be
required to satisfactorily demonstrate to the FDOT District Utilities Administrator that they
have the following knowledge, skills, and expertise:

A minimum of 4 years of experience performing utility coordination in accordance with


FDOT, Federal Highway Administration (FHWA), and American Association of State
Highway and Transportation Officials (AASHTO) standards, policies, and procedures.

A thorough knowledge of the FDOT plans production process and District utility
coordination process.

2 PROJECT DESCRIPTION
A-7
STAGE I FPID(S): 999999-1-52-01
[DATE]

A thorough knowledge of FDOT agreements, standards, policies, and procedures.

The Utility Coordination Manager shall be responsible for managing all utility coordination,
including the following:

Assuring that Utility Coordination and accommodation is in accordance to the FDOT,


FHWA, and AASHTO standards, policies, procedures, and design criteria.

Assisting the engineer of record in identifying all existing utilities and coordinating any new
installations. Assisting the Engineer of Record with resolving utility conflicts.

Scheduling and performing utility coordination meetings, keeping and distribution of


minutes/action items of all utility meetings, and ensuring expedient follow-up on all
unresolved issues.

Distributing all plans, conflict matrixes and changes to affected utility owners and making
sure this information is properly coordinated and documented.

Identifying and coordinating the completion of any FDOT or utility owner agreement that is
required for reimbursement, or accommodation of the utility facilities associated with the
project.

Review and certify to the District Utilities Administrator that all Utility Work Schedules are
correct and in accordance with the Departments standards, policies, and procedures.

Prepare, review and process all utility related reimbursable paperwork inclusive of
betterment and salvage determination.

The CONSULTANTs utility coordination work shall be performed and directed by the
Utility Coordination Manager that was identified and approved by FDOTs Project Manager.
Any proposed change of the approved Utility Coordination Manager shall be subject to
review and approval by FDOTs Project Manager prior to any change being made in this
contract.

[List utilities anticipated on the project].

2.4 Environmental Permits, Compliances, and Clearances (Activity 8)

[List expected permits, i.e., USCG, COE, WMD, etc].

The DEPARTMENT will provide compensatory wetland mitigation in accordance with


Section 373.4137, Florida Statutes.

2 PROJECT DESCRIPTION
A-8
STAGE I FPID(S): 999999-1-52-01
[DATE]

2.5 Structures (Activities 9 18)

Bridge(s): [List bridge number(s) (for each bridge describe the typical section,
location, length, and other pertinent information to define the scope of the
proposed bridge work) or N/A].

Type of Bridge Structure Work:

BDR
Temporary Bridge
Short Span Concrete
Medium Span Concrete
Structural Steel
Segmental Concrete
Movable Span

Retaining Walls: [List lengths and types of temporary and/or permanent retaining
walls. Temporary _____ LF, Permanent: _____ LF or N/A].

Noise Barrier Walls: [List lengths and types of temporary and/or permanent noise
barrier walls. Temporary ______ LF, Permanent: __________ LF or N/A]

Miscellaneous: [List miscellaneous structure services (i.e., box culvert extensions,


overhead sign structures, foundations, mast arms, high mast lighting, noise
barrier walls, special drainage structures, etc.) or N/A]

2.6 Signing and Pavement Markings (Activities 19 & 20)

[List number and location of sign structures (i.e., cantilevers, overhead, etc.) or
N/A]

2.7 Signalization (Activities 21 & 22)

Intersections: [List all existing and proposed signalized intersections and


requirements, (i.e., loop replacement, mast arms, etc.) or N/A].

Traffic Data Collection: [List all locations that will require data collection. Describe
data to be collected at each location or N/A].

Traffic Studies: [List all studies required and locations or N/A].

Count Stations: [List number of count stations or N/A].

Traffic Monitoring Sites: [List number of Traffic Monitoring Sites on or within one-
half mile of project or N/A].

2.8 Lighting (Activities 23 & 24)

[Provide limits and proposed type of lighting. Describe lighting reports required or

2 PROJECT DESCRIPTION
A-9
STAGE I FPID(S): 999999-1-52-01
[DATE]

N/A].

2.9 Landscape Architecture (Activities 25 & 26)

Include coordination with existing and/or proposed underground utilities including but not
limited to FDOT lighting, drainage and ITS. Landscape coordination with ITS shall include
both underground conflicts and above-ground impacts to existing and/or proposed ITS
coverage. The CONSULTANT shall closely coordinate with the Departments ITS units to
ensure that all conflicts are identified, addressed and mitigated in the Contract Documents.

Planting Plans: [List project length and location (name of street and limits, median,
roadside), landscape intensity (rural, suburban, urban) and landscape type
(buffer, xeric, gateway, native, restoration, mitigation, tree relocation, streetscape,
etc.) or N/A].

Irrigation Plans: [List applicable local codes and ordinance, system type (spray,
subsurface, low volume, etc.), water source (potable, re-use water, well, metering,
backflow type), power source (electrical, solar, battery), control options (local,
satellite, manual, etc.) and provide for sleeve location coordination or N/A].

Hardscape Plans: [Indicate if plans include the following: street furniture (litter
receptacles, benches, bus shelters, bollards, tree grates and guards, etc.), specialty
lighting (street poles and fixtures, landscape lighting, bridge lighting, etc.),
specialty paving (concrete, brick or asphalt pavers, stamped, colored concrete or
asphalt, etc.), sidewalks, plazas, steps, fountains, walls, pedestrian bridges and any
non-regulatory signs or project graphics or N/A].

Outdoor Advertising: [Indicate if view zones of legally permitted outdoor advertising


signs are within the project limits. List the number of sign structures, the number
of sign faces (single, double, triple faced), and the number of sign permittees that
must be contacted for coordination with the landscape architect or N/A].

2.10 Survey (Activity 27)

Design Survey: [Provide limits and description or N/A].

Subsurface Utility Exploration: [Provide locations and description or N/A].

Right of Way Survey: [Provide limits and description or N/A].

Vegetation Survey: [Provide limits and description or N/A].

2.11 Photogrammetry (Activity 28)

[Provide limits and describe type or N/A].

2.12 Mapping (Activity 29)

Control Survey Map: [Provide limits or N/A].

2 PROJECT DESCRIPTION
A-10
STAGE I FPID(S): 999999-1-52-01
[DATE]

Right of Way Map: [Provide limits or N/A].

Legal Descriptions: [Provide number or N/A]

Maintenance Map: [Provide limits or N/A].

Miscellaneous Items: [List items or N/A].

2.13 Terrestrial Mobile LiDAR (Activity 30)

[Provide limits and describe type or N/A].

2.14 Architecture (Activity 31)

[Provide description of work and add project-specific scope language or N/A].

LEED (Leadership in Energy and Environmental Design)

The intent of the LEED Green Building Rating System is the promotion of the design,
construction and maintenance of buildings that are durable, healthy, affordable, and
environmentally sound. This is achieved through an approach that looks not only at the
building but also includes the surrounding area. Among the elements LEED includes are
access to public transportation, energy usage, daylighting and views, indoor air quality,
transportation, water usage, stormwater runoff, recycling, and renewable resources.

Prerequisites and credits are the two types of tasks required by LEED to rate a buildings
environmental impact. Prerequisites are mandatory and must be achieved for a building to
meet any certification level; however no points are earned for their completion. Points are
earned for each credit that is achieved with points varying from credit to credit. Not all
credits will be achievable due to external conditions while other credits will be too involved
or costly to pursue. This is where the design team and the FDOT must determine what
credits are to be pursued and the level of certification to strive to meet.

The State has set Certified as the minimum target level of certification for buildings,
though several Department projects have strived for a LEED Green Building Rating of
Silver.

Hours include the efforts to design and receive certification for buildings. These hours
include all disciplines involved in the effort.

2.15 Noise Barriers (Activity 32)

[Provide description of work and add project-specific scope language or N/A]

2.16 Intelligent Transportation Systems (Activities 33 & 34)

[Provide description of ITS elements and work expected within project limits
including all supporting infrastructure and equipment, short narrative for
purpose, ITS hardware descriptions, communications design, need for test and
acceptance procedures on the local subsystem, and system levels. Provide an
overview of existing and proposed ITS devices, proposed ITS communications to

2 PROJECT DESCRIPTION
A-11
STAGE I FPID(S): 999999-1-52-01
[DATE]

the transportation management center (TMC), power requirements, operational


requirements, and maintenance requirements. The description must include
reference to the Regional ITS Architecture and Rule 940 requirements if federal
funds are included or N/A.]

The Federal Highway Administration issued Rule 940 entitled Intelligent Transportation
Systems (ITS) Architecture and Standards to ensure new projects conform to the National
ITS Architecture and standards as well as with a regional ITS architecture developed to
reflect the local needs, issues, problems, and objectives for implementation.

For all projects with ITS activities, the CONSULTANT shall follow the Rule 940
requirements and use a Systems Engineering approach for determining the requirements for
the project. The CONSULTANT shall develop all necessary documents to support the Rule
940 requirements like Concept of Operations (ConOPS), Systems Engineering Management
Plan (SEMP), Requirements Traceability Verification Matrix (RTVM) and others as deemed
necessary by the Department.

[Describe the hardware configuration analysis and design including system


architecture, interfaces, communications, equipment, devices and computers.]

[If relevant, mention any prior reports done such as concept reports, etc.]

The ITS shall operate from the [NAME] TMC located at [LOCATION] using the
SunGuide (SunGuide) Software, or if SunGuide is not in use at [NAME] TMC, using the
appropriate [NAME SOFTWARE PACKAGE].

Interchanges: [List all existing and proposed interchanges and ITS field device
requirements for tie-in to arterials or N/A].

Traffic Data Collection: [List all locations that will require data collection. Describe
data to be collected at each location.]

Geographical Information System (GIS) Requirements: CONSULTANT shall include in the


design the GIS data collection requirements and deliverables for integration with SunGuide
software and other Department GIS based asset management applications like ITS FM
software.

All design efforts shall be based on deploying open architecture subsystems, while
remaining fully compatible with previous designs (as applicable) and the FDOT ITS
Specifications. All ITS field devices and support systems shall be designed and located
outside of the clear zone, or behind protective barrier, within the right of way. This includes
cabinets, poles, and support hardware. Utility conflicts shall be identified and resolved
during the design phase. The location of design elements will be coordinated with the
District Landscape Architect to optimize landscape opportunities. The design shall minimize
theft and vandalism. The CONSULTANT shall include in the design vandal resistant
mechanisms to minimize theft. The CONSULTANT shall provide additional redundant
power and communications systems to minimize system downtime due to vandalism.

The CONSULTANT shall design the project subsystems such that they will be monitored
and controlled from the FDOTs TMC facilities located at [LOCATION(S)]. The
CONSULTANT shall ensure that all ITS field devices and ancillary components comply
with the FDOTs Approved Product List (APL) and are supported within the SunGuide
2 PROJECT DESCRIPTION
A-12
STAGE I FPID(S): 999999-1-52-01
[DATE]

software or other specified software, unless otherwise approved by the DEPARTMENT.

The CONSULTANT shall include in the design any required upgrade to the TMC central
hardware, equipment racks, and equipment wiring, as directed by the FDOT project
manager, to make the subsystems fully operations from the TMC facilities.

For projects with existing ITS, the CONSULTANT shall include in the design any required
upgrade to existing ITS equipment to meet the latest FDOT standards, NEC requirements or
as directed by the FDOT project manager and to make the subsystems fully operations from
the TMC facilities.

ITS coordination with Landscape Architecture shall include both underground conflicts and
above-ground impacts to existing and/or proposed Landscaping. The CONSULTANT shall
closely coordinate with the Landscape Architect to ensure that all conflicts are identified,
addressed and mitigated in the Contract Documents.

2.17 Geotechnical (Activity 35)

[Define geotechnical responsibilities; i.e., DEPARTMENT or CONSULTANT or


N/A].

[List types of borings and unique lab tests, i.e., roadway, structures, ponds,
lighting, etc.]

2.18 3D Modeling (Activity 36)

[Describe level of effort or N/A].

2.19 Project Schedule

Within ten (10) days after the Notice-To-Proceed, and prior to the CONSULTANT beginning
work, the CONSULTANT shall provide a detailed project activity/event schedule for
DEPARTMENT and CONSULTANT scheduled activities required to meet the current
DEPARTMENT Production Date. The schedule shall be based upon the [FILL IN
DISTRICT SCHEDULE INFORMATION]. The current production date is [Month
00, 20XX]. The schedule shall be accompanied by an anticipated payout and fiscal progress
curve. For the purpose of scheduling, the CONSULTANT shall allow for a [fill in blank]
week review time for each phase submittal and any other submittals as appropriate.

The schedule shall indicate all required submittals.

All fees and price proposals are to be based on the negotiated schedule of [XX] months for
final construction contract documents. However, the contract deadline is [XX] months from
the Notice to Proceed.

Periodically, throughout the life of the contract, the project schedule and payout and fiscal
progress curves shall be reviewed and, with the approval of the DEPARTMENT, adjusted as
necessary to incorporate changes in the Scope of Services and progress to date.

The approved schedule and schedule status report, along with progress and payout curves,
shall be submitted with the monthly progress report.

2 PROJECT DESCRIPTION
A-13
STAGE I FPID(S): 999999-1-52-01
[DATE]

The schedule shall be submitted in an FDOT system-compatible format.

2.20 Submittals

The CONSULTANT shall furnish construction contract documents as required by the


DEPARTMENT to adequately control, coordinate, and approve the work concepts. The
CONSULTANT shall distribute submittals as directed by the DEPARTMENT. The
DEPARTMENT will determine the specific number of copies required prior to each
submittal.

2.21 Provisions for Work

All work shall be prepared with English units in accordance with the latest editions of
standards and requirements utilized by the DEPARTMENT which include, but are not
limited to, publications such as:

General
o Title 29, Part 1910, Standard 1910.1001, Code of Federal Regulations (29
C.F.R. 1910.1001) Asbestos Standard for Industry, U.S. Occupational
Safety and Health Administration (OSHA)
o 29 C.F.R. 1926.1101 Asbestos Standard for Construction, OSHA
o 40 C.F.R. 61, Subpart M - National Emission Standard for Hazardous Air
Pollutants (NESHAP), Environmental Protection Agency (EPA)
o 40 C.F.R. 763, Subpart E Asbestos-Containing Materials in Schools, EPA
o 40 C.F.R. 763, Subpart G Asbestos Worker Protection, EPA
o Americans with Disabilities Act (ADA) Standards for Accessible Design
o AASHTO A Policy on Design Standards Interstate System
o AASHTO Roadside Design Guide
o AASHTO Roadway Lighting Design Guide
o AASHTO A Policy for Geometric Design of Highways and Streets
o AASHTO Highway Safety Manual
o Rule Chapter 5J-17, Florida Administrative Code (F.A.C.), Standards of
Practice for Professional Surveyors and Mappers
o Chapter 469, Florida Statutes (F.S.) Asbestos Abatement
o Rule Chapter 62-257, F.A.C., Asbestos Program
o Rule Chapter 62-302, F.A.C., Surface Water Quality Standards
o Code of Federal Regulations (C.F.R.)
o Florida Administrative Codes (F.A.C.)
o Chapters 20, 120, 215, 455, Florida Statutes (F.S.) Florida Department of
Business & Professional Regulations Rules
o Florida Department of Environmental Protection Rules
o FDOT Basis of Estimates Manual
o FDOT Computer Aided Design and Drafting (CADD) Manual
o FDOT Design Standards
o FDOT Flexible Pavement Design Manual
o FDOT - Florida Roundabout Guide

2 PROJECT DESCRIPTION
A-14
STAGE I FPID(S): 999999-1-52-01
[DATE]

o FDOT Handbook for Preparation of Specifications Package


o FDOT Instructions for Design Standards
o FDOT Instructions for Structures Related Design Standards
o FDOT Manual of Uniform Minimum Standards for Design, Construction and
Maintenance for Streets and Highways (Florida Greenbook)
o FDOT Materials Manual
o FDOT Pavement Type Selection Manual
o FDOT Plans Preparation Manual
o FDOT Procedures and Policies
o FDOT Project Development and Environmental Manual
o FDOT Project Traffic Forecasting Handbook
o FDOT Public Involvement Handbook
o FDOT Rigid Pavement Design Manual
o FDOT Standard Specifications for Road and Bridge Construction
o FDOT Utility Accommodation Manual
o Federal Highway Administration (FHWA) - Manual on Uniform Traffic
Control Devices (MUTCD)
o FHWA National Cooperative Highway Research Program (NCHRP) Report
672, Roundabouts: An Informational Guide
o FHWA Roadway Construction Noise Model (RCNM) and Guideline
Handbook
o Florida Fish and Wildlife Conservation Commission - Standard Manatee
Construction Conditions 2005
o Florida Statutes (F.S.)
o Floridas Level of Service Standards and Guidelines Manual for Planning
o Model Guide Specifications Asbestos Abatement and Management in
Buildings, National Institute for Building Sciences (NIBS)
o Quality Assurance Guidelines
o Safety Standards
o Any special instructions from the DEPARTMENT
Roadway
o FDOT Florida Intersection Design Guide
o FDOT - Project Traffic Forecasting Handbook
o FDOT - Quality/Level of Service Handbook
o Floridas Level of Service Standards and Highway Capacity Analysis for the
SHS
o Transportation Research Board (TRB) - Highway Capacity Manual
Permits
o Chapter 373, F.S. Water Resources
o US Fish and Wildlife Service Endangered Species Programs
o Florida Fish and Wildlife Conservation Commission Protected Wildlife
Permits

2 PROJECT DESCRIPTION
A-15
STAGE I FPID(S): 999999-1-52-01
[DATE]

o Bridge Permit Application Guide, COMDTPUB P16591.3C


o Building Permit
Drainage
o FDOT Bridge Hydraulics Handbook
o FDOT Culvert Handbook
o FDOT Drainage Manual
o FDOT Erosion and Sediment Control Manual
o FDOT Exfiltration Handbook
o FDOT Hydrology Handbook
o FDOT Open Channel Handbook
o FDOT Optional Pipe Materials Handbook
o FDOT Storm Drain Handbook
o FDOT Stormwater Management Facility Handbook
o FDOT Temporary Drainage Handbook
o FDOT Drainage Connection Permit Handbook
o FDOT Bridge Scour Manual
Survey and Mapping
o All applicable Florida Statutes and Administrative Codes
o Applicable Rules, Guidelines Codes and authorities of other Municipal,
County, State and Federal Agencies.
o FDOT Aerial Surveying Standards for Transportation Projects Topic 550-020-
002
o FDOT Right of Way Mapping Handbook
o FDOT Surveying Procedure Topic 550-030-101
o Florida Department of Transportation Right of Way Procedures Manual
o Florida Department of Transportation Surveying Handbook
o Right of Way Mapping Procedure 550-030-015
Traffic Engineering and Operations and ITS
o AASHTO - An Information Guide for Highway Lighting
o AASHTO - Guide for Development of Bicycle Facilities
o FHWA Standard Highway Signs Manual
o FDOT Manual on Uniform Traffic Studies (MUTS)
o FDOT Median Handbook
o FDOT Traffic Engineering Manual
o National Electric Safety Code
o National Electrical Code
Floridas Turnpike Enterprise
o Floridas Turnpike Plans Preparation and Practices Handbook (TPPPH)
o Floridas Turnpike Lane Closure Policy
o Floridas Turnpike Drainage Manual Supplement

2 PROJECT DESCRIPTION
A-16
STAGE I FPID(S): 999999-1-52-01
[DATE]

o Rigid Pavement Design Guide for Toll Locations with Electronic Toll
Collection
o Flexible Pavement Design Guide for Toll Locations with Electronic Toll
Collection
o Floridas Turnpike General Tolling Requirements (GTR)
o Additional Floridas Turnpike Enterprise standards, guides, and policies for
design and construction can be found on the FTE Design Website:
http://design.floridasturnpike.com
Traffic Monitoring
o American Institute of Steel Construction (AISC) Manual of Steel
Construction, referred to as AISC Specifications
o American National Standards Institute (ANSI) RP-8-00 Recommended
Practice for Roadway Lighting
o AASHTO AWS D1.1/ANSI Structural Welding Code Steel
o AASHTO D1.5/AWS D1.5 Bridge Welding Code
o FHWA Traffic Detector Handbook
o FDOT General Interest Roadway Data Procedure
o FHWA Traffic Monitoring Guide
o FDOTs Traffic/Polling Equipment Procedures
Structures
o AASHTO Load and Resistance Factor Design (LRFD) Bridge Design
Specifications and Interims
o AASHTO LRFD Movable Highway Bridge Design Specifications and
Interims
o AASHTO Standard Specifications for Structural Supports for Highway Signs,
Luminaires and Traffic Signals, and Interims.
o AASHTO/-AWS-D1. 5M/D1.5: An American National Standard Bridge
Welding Code
o AASHTO Guide Specifications for Structural Design of Sound Barriers
o AASHTO Manual for Condition Evaluation and Load and Resistance Factor
Rating (LRFR) of Highway Bridges
o FDOT Bridge Load Rating Manual
o FDOT Structures Manual
o FDOT Structures Design Bulletins (available on FDOT Structures web site
only)
o
Geotechnical
o FHWA Checklist and Guidelines for Review of Geotechnical Reports and
Preliminary Specifications
o Manual of Florida Sampling and Testing Methods
o Soils and Foundation Handbook
Landscape Architecture
2 PROJECT DESCRIPTION
A-17
STAGE I FPID(S): 999999-1-52-01
[DATE]

o Florida Department of Agriculture and Consumer Services Grades and


Standards for Nursery Plants
Architectural
o Building Codes
o Florida Building Code:
Building
Fuel Gas
Mechanical
Plumbing
Existing Building
o Florida Accessibility Code for Building Construction
o Rule Chapter 60D, F.A.C., Division of Building Construction
o Chapter 553, F.S. Building Construction Standards
o ANSI A117.1 2003 Accessible and Usable Building and Facilities
o Titles II and III, Americans With Disabilities Act (ADA), Public Law 101-
336; and the ADA Accessibility Guidelines (ADAAG)
Architectural Fire Codes and Rules
o National Fire Protection Association (NFPA) - Life Safety Code
o NFPA 70 - National Electrical Code
o NFPA 101 - Life Safety Code
o NFPA 10 - Standard for Portable Fire Extinguishers
o NFPA 11 - Standard for Low-Expansion Foam Systems
o NFPA 11A - Standard for High- and Medium-Expansion Foam Systems
o NFPA 12 - Standard for Carbon Dioxide Extinguishing Systems
o NFPA 13 - Installation of Sprinkler Systems
o NFPA 30 - Flammable and Combustible Liquids Code
o NFPA 54 - National Gas Fuel Code
o NFPA 58 - LP-Gas Code
o Florida Fire Prevention Code as adopted by the State Fire Marshal
Consult with the Florida State Fire Marshals office for other frequently
used codes.
Architectural Extinguishing Systems
o NFPA 10 - Fire Extinguishers
o NFPA 13 - Sprinkler
o NFPA 14 - Standpipe and Hose System
o NFPA 17 - Dry Chemical
o NFPA 20 - Centrifugal Fire Pump
o NFPA 24 - Private Fire Service Mains
o NFPA 200 - Standard on Clean Agent Fire Extinguishing Systems
Architectural Detection and Fire Alarm Systems

2 PROJECT DESCRIPTION
A-18
STAGE I FPID(S): 999999-1-52-01
[DATE]

o NFPA 70 - Electrical Code


o NFPA 72 - Standard for the Installation, Maintenance and Use of Local
Protective Signaling Systems
o NFPA 72E - Automatic Fire Detectors
o NFPA 72G - Installation, Maintenance, and Use of Notification Appliances
o NFPA 72H -Testing Procedures for Remote Station and Proprietary Systems
o NFPA 74 - Household Fire Warning Equipment
o NFPA 75 - Protection of Electronic Computer Equipment
Architectural Mechanical Systems
o NFPA 90A - Air Conditioning and Ventilating Systems
o NFPA 92A - Smoke Control Systems
o NFPA 96 - Removal of Smoke and Grease-Laden Vapors from Commercial
Cooking Equipment
o NFPA 204M - Smoke and Heating Venting
Architectural Miscellaneous Systems
o NFPA 45 - Laboratories Using Chemicals
o NFPA 80 - Fire Doors and Windows
o NFPA 88A - Parking Structures
o NFPA 105- Smoke and Draft-control Door Assemblies
o NFPA 110 - Emergency and Standby Power Systems
o NFPA 220 - Types of Building Construction
o NFPA 241 - Safeguard Construction, Alteration, and Operations
o Rule Chapter 69A-47, F.A.C., Uniform Fire Safety For Elevators
o Rule Chapter 69A-51, F.A.C., Boiler Safety
Architectural Energy Conservation
o Rule Chapter 60D-4, F.A.C., Rules For Construction and Leasing of State
Buildings To Insure Energy Conservation
o Section 255.255, F.S., Life-Cycle Costs
Architectural Elevators
o Rule Chapter 61C-5, F.A.C., Florida Elevator Safety Code
o ASME A-17.1, Safety Code for Elevators and Escalators
o Architectural Floodplain Management Criteria
o Section 255.25, F.S., Approval Required Prior to Construction or Lease of
Buildings
o Rules of the Federal Emergency Management Agency (FEMA)
Architectural Other
o Rule Chapter 64E-6, F.A.C., Standards for On Site Sewage Disposal Systems
(Septic Tanks)
o Rule Chapter 62-600, F.A.C., Domestic Wastewater Facilities
o Rule Chapter 62-761, F.A.C., Underground Storage Tank Systems

2 PROJECT DESCRIPTION
A-19
STAGE I FPID(S): 999999-1-52-01
[DATE]

o American Concrete Institute


o American Institute of Architects - Architects Handbook of Professional
Practice
o American Society for Testing and Materials - ASTM Standards
o Brick Institute of America
o DMS - Standards for Design of State Facilities
o Florida Concrete Products Association
o FDOT ADA/Accessibility Procedure
o FDOT Building Code Compliance Procedure
o FDOT Design Build Procurement and Administration
o LEED (Leadership in Energy and Environmental Design) Green Building
Rating System
o National Concrete Masonry Association
o National Electrical Code
o Portland Cement Association - Concrete Masonry Handbook
o United State Green Building Council (USGBC)
2.22 Services to be Performed by the DEPARTMENT When appropriate and /or
available, the DEPARTMENT will provide project data including:
Numbers for field books.
Preliminary Horizontal Network Control.
Access for the CONSULTANT to utilize the DEPARTMENTs Information
Technology Resources.
All Department agreements with Utility Agency Owner (UAO).
All certifications necessary for project letting.
Building Construction Permit Coordination (Turnpike)
All information that may come to the DEPARTMENT pertaining to future
improvements.
All future information that may come to the DEPARTMENT during the term of
the CONSULTANTs Agreement, which in the opinion of the DEPARTMENT
is necessary for the prosecution of the work.
Available traffic and planning data.
All approved utility relocations.
Project utility certification to the DEPARTMENTs Central Office.
Any necessary title searches.
Engineering standards review services.
All available information in the possession of the DEPARTMENT pertaining to
utility companies whose facilities may be affected by the proposed construction.
All future information that may come to the DEPARTMENT pertaining to
subdivision plans so that the CONSULTANT may take advantage of additional
areas that can be utilized as part of the existing right of way.
Systems traffic for Projected Design Year, with K, D, and T factors.
Previously constructed Highway Beautification or Landscape Construction
Plans
Landscape Opportunity Plan(s)
Existing right of way maps.
2 PROJECT DESCRIPTION
A-20
STAGE I FPID(S): 999999-1-52-01
[DATE]

Existing cross slope data for all RRR projects.


Existing pavement evaluation report for all RRR projects.
PD&E Documents
Design Reports
Letters of authorization designating the CONSULTANT as an agent of the
DEPARTMENT in accordance with F.S. 337.274.
Phase reviews of plans and engineering documents.
Regarding Environmental Permitting Services:
o Approved Permit Document when available.
o Approval of all contacts with environmental agencies.
o General philosophies and guidelines of the DEPARTMENT to be used in the
fulfillment of this contract. Objectives, constraints, budgetary limitations,
and time constraints will be completely defined by the Project Manager.
o Appropriate signatures on application forms.

2 PROJECT DESCRIPTION
A-21
STAGE I FPID(S): 999999-1-52-01
[DATE]

3 PROJECT COMMON AND PROJECT GENERAL TASKS

Project Common Tasks

Project Common Tasks, as listed below, are work efforts that are applicable to many project
activities, 4 (Roadway Analysis) through 35 (Geotechnical). These tasks are to be included
in the project scope in each applicable activity when the described work is to be performed
by the CONSULTANT.

Cost Estimates: The CONSULTANT shall be responsible for producing a construction cost
estimate and reviewing and updating the cost estimate when scope changes occur and/or at
milestones of the project. Prior to 60% plans and completion of quantities, the
DEPARTMENTs Long Range Estimate (L.R.E.) system will be used to produce a
conceptual estimate, according to District policy. Once the quantities have been developed
(beginning at 60% plans and no later than 90% plans) the CONSULTANT shall be
responsible for inputting the pay items and quantities into AASHTOWare Project
Preconstruction through the use of the DEPARTMENTs Designer Interface for generating
the summary of quantities and the FDOTs in-house estimates. A Summary of Pay Items
sheet shall be prepared with all required Phase II, III, and IV Plans submittals.

Technical Special Provisions: The CONSULTANT shall provide Technical Special


Provisions for all items of work not covered by the Standard Specifications for Road and
Bridge Construction and the workbook of implemented modifications.

A Technical Special Provision shall not modify the first nine sections of the Standard
Specifications and implemented modifications in any way. All modifications to other
sections must be justified to the appropriate District Specifications Office to be included in
the project's specifications package.

The Technical Special Provisions shall provide a description of work, materials, equipment
and specific requirements, method of measurement and basis of payment. Proposed
Technical Special Provisions will be submitted to the District Specifications Office for initial
review at the time of the Phase III plans review submission to the DEPARTMENTs Project
Manager. This timing will allow for adequate processing time prior to final submittal. The
Technical Special Provisions will be reviewed for suitability in accordance with the
Handbook for Preparation of Specification Packages. The District Specifications Office will
forward the Technical Special Provisions to the District Legal Office for their review and
comment. All comments will be returned to the CONSULTANT for correction and
resolution. Final Technical Special Provisions shall be digitally signed and sealed in
accordance with applicable Florida Statutes.

The CONSULTANT shall contact the appropriate District Specifications Office for details of
the current format to be used before starting preparations of Technical Special Provisions.

Field Reviews: The CONSULTANT shall make as many trips to the project site as required

3 PROJECT COMMON AND PROJECT GENERAL TASKS


A-22
STAGE I FPID(S): 999999-1-52-01
[DATE]

to obtain necessary data for all elements of the project.

Technical Meetings: The CONSULTANT shall attend all technical meetings necessary to
execute the Scope of Services of this contract. This includes meetings with DEPARTMENT
and/or Agency staff, between disciplines and subconsultants, such as access management
meetings, pavement design meetings, local governments, railroads, airports, progress review
meetings (phase review), and miscellaneous meetings. The CONSULTANT shall prepare,
and submit to the DEPARTMENTs Project Manager for review, the meeting minutes for all
meetings attended by them. The meeting minutes are due within five (5) working days of
attending the meeting.

Quality Assurance/Quality Control: It is the intention of the DEPARTMENT that design


CONSULTANTS, including their subconsultant(s), are held responsible for their work,
including plans review. The purpose of CONSULTANT plan reviews is to ensure that
CONSULTANT plans follow the plan preparation procedures outlined in the Plans
Preparation Manual, that state and federal design criteria are followed with the
DEPARTMENT concept, and that the CONSULTANT submittals are complete. All
subconsultant document submittals shall be submitted by the subconsultant directly to the
CONSULTANT for their independent Quality Assurance/Quality Control review and
subsequent submittal to the DEPARTMENT.

It is the CONSULTANT'S responsibility to independently and continually QC their plans


and other deliverables. The CONSULTANT should regularly communicate with the
DEPARTMENT's Design Project Manager to discuss and resolve issues or solicit opinions
from those within designated areas of expertise.

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of all surveys, designs, drawings, specifications and other services furnished by
the CONSULTANT and their subconsultant(s) under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all maps, design drawings, specifications,
and other documentation prepared as a part of the contract. The CONSULTANT shall
describe how the checking and review processes are to be documented to verify that the
required procedures were followed. The Quality Control Plan shall be one specifically
designed for this project. The CONSULTANT shall submit a Quality Control Plan for
approval within twenty (20) business days of the written Notice to Proceed and it shall be
signed by the CONSULTANTs Project Manager and the CONSULTANT QC Manager. The
Quality Control Plan shall include the names of the CONSULTANTs staff that will perform
the quality control reviews. The Quality Control reviewer shall be a Florida Licensed
Professional Engineer fully prequalified under F.A.C. 14-75 in the work type being
reviewed. A marked up set of prints from a Quality Control Review indicating the reviewers
for each component (structures, roadway, drainage, signals, geotechnical, signing and
marking, lighting, landscape, surveys, etc.) and a written resolution of comments on a point-
by-point basis will be required, if requested by the DEPARTMENT, with each phase
submittal. The responsible Professional Engineer, Landscape Architect, or Professional
Surveyor & Mapper that performed the Quality Control review will sign a statement
3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-23
STAGE I FPID(S): 999999-1-52-01
[DATE]

certifying that the review was conducted and found to meet required specifications.

The CONSULTANT shall, without additional compensation, correct all errors or


deficiencies in the designs, maps, drawings, specifications and/or other products and
services.

Independent Peer Review: When directed by the DEPARTMENT, a subconsultant may


perform Independent Peer Reviews.

Independent Peer Review and a Constructability/Bidability Review for design Phase Plans
document submittals are required on this project. These separate reviews shall be completed
by someone who has not worked on the plan component that is being reviewed. These could
include, but are not limited to a separate office under the Primes umbrella, a subconsultant
that is qualified in the work group being reviewed, or a CEI. It does not include persons who
have knowledge of the day to day design efforts. The Constructability/Bidability Review
shall be performed by a person with experience working on Department construction
projects (CEI, Contractor, etc.).

The Independent Peer Review for design Phase Plans submittals shall ensure the plans meet
the PPM, Design Standards and CADD Manual. The Constructability/Bidability Review
shall ensure the project can be constructed and paid for as designed.
Constructability/Bidability Reviews should be conducted prior to the Phase III and Phase IV
submittals, using the Phase Review Checklist (Guidance Document 1-1-A) from the
Construction Project Administration Manual (CPAM) as a minimum guideline. The
CONSULTANT shall submit this checklist, as well as the marked-up set of plans during
this review, and review comments and comment responses from any previous
Constructability/Bidability reviews. These items will be reviewed by District Design and
District Construction.

Supervision: The CONSULTANT shall supervise all technical design activities.

Coordination: The CONSULTANT shall coordinate with all disciplines of the project to
produce a final set of construction documents.

Project General Tasks

Project General Tasks, described in Sections 3.1 through 3.7 below, represent work efforts
that are applicable to the project as a whole and not to any one or more specific project
activity. The work described in these tasks shall be performed by the CONSULTANT when
included in the project scope.

3.1 Public Involvement

Public involvement includes communicating to all interested persons, groups, and


government organizations information regarding the development of the project. The
CONSULTANT shall provide to the DEPARTMENT drafts of all Public Involvement
documents (i.e., newsletters, property owner letters, advertisements, etc.) associated with the
following tasks for review and approval at least [number (XX)] business days prior to

3 PROJECT COMMON AND PROJECT GENERAL TASKS


A-24
STAGE I FPID(S): 999999-1-52-01
[DATE]

printing and / or distribution.

3.1.1 Community Awareness Plan

Prepare a Community Awareness Plan (CAP) for review and approval by the
DEPARTMENT within 30 calendar days after receiving Notice to Proceed. The objective of
the plan is to notify local governments, affected property owners, tenants, and the public of
the DEPARTMENTS proposed construction and the anticipated impact of that construction.
The CAP shall address timeframes for each review and shall include tentative dates for each
public involvement requirement for the project. The CAP will also document all public
involvement activities conducted throughout the projects duration. In addition to the
benefits of advance notification, the process should allow the DEPARTMENT to resolve
controversial issues during the design phase. This item shall be reviewed and updated
periodically as directed by the DEPARTMENT throughout the life of the project.

3.1.2 Notifications

In addition to public involvement data collection, the CONSULTANT shall assist the
DEPARTMENT or prepare notifications, flyers, and/or letters to elected officials and other
public officials, private property owners, and tenants at intervals during plans production as
identified by the DEPARTMENT. All letters and notices shall be reviewed by the
[DEPARTMENT/CONSULTANT] to ensure that they are addressed to the correct and
current public officials.

3.1.3 Preparing Mailing Lists

At the beginning of the project, The CONSULTANT shall identify all impacted property
owners and tenants (within a minimum of 300 feet of the project corridor) The
CONSULTANT shall prepare a mailing list of all such entities and shall update the mailing
list as needed during the life of the project.

3.1.4 Median Modification Letters

The CONSULTANT shall prepare a median modification letter to be sent to property owners
along the corridor. In addition, the CONSULTANT shall prepare a sketch of each proposed
median modification for inclusion in the letter. The letters will be sent on DEPARTMENT
letterhead by the [DEPARTMENT/CONSULTANT] .

3.1.5 Driveway Modification Letters

The CONSULTANT shall prepare a driveway modification letter to be sent to property


owners along the corridor. In addition, the CONSULTANT shall prepare a sketch of each
proposed driveway modification for inclusion in the letter. The letters will be sent on
DEPARTMENT letterhead.

3.1.6 Newsletters

The CONSULTANT shall prepare newsletters for distribution to elected officials, public
officials, property owners along the corridor and other interested parties. The letters will be
sent by the CONSULTANT.

3.1.7 Renderings and Fly-Throughs


3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-25
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall prepare renderings and fly-throughs for use in public meetings.

3.1.8 PowerPoint Presentations

The CONSULTANT shall prepare PowerPoint presentations for use in public meetings.

3.1.9 Public Meeting Preparations

The CONSULTANT shall prepare the necessary materials for use in public meetings.

The CONSULTANT will investigate potential meeting sites to advise the DEPARTMENT
on their suitability. The [DEPARTMENT/CONSULTANT] will pay all costs for meeting
site rents and insurance. No DEPARTMENT meetings will be held on public school system
properties.

3.1.10 Public Meeting Attendance and Follow-up

The CONSULTANT shall attend public meeting(s), assist with meeting setup and take
down. The CONSULTANT shall also prepare a summary of the public meeting that
includes all copies of all materials shown or provided at the public meeting. The summary
shall also include a listing of all written comments made during or after the meeting and
responses to those written comments.

The CONSULTANT will attend the meetings with an appropriate number of personnel to
assist the DEPARTMENT'S Project Manager.

It is estimated for this project there will be [XXX] Public meetings during the design.

3.1.11 Other Agency Meetings

In addition to scheduled public meetings the CONSULTANT may be required to participate


in meetings with local governing authorities and/or Metropolitan Planning Organization
(MPO). The CONSULTANTs participation may include, but not be limited to, presentations
during the meeting, note taking, and summarizing the meeting in a memo to the file. It is
estimated for this project there will be [XXX] meetings with local governing authorities
and/or MPOs during the design.

3.1.12 Web Site

The CONSULTANT shall create and/or maintain a web site for the project.

3.2 Joint Project Agreements

When the Joint Project Agreement (JPA) deliverable is not prepared by the CONSULTANT,
services may include all coordination, meetings, etc., required to ensure compatibility,
include JPA documents in the contract plans package and include the JPA documents in the
digital delivery package.

3.3 Specifications Package Preparation

The CONSULTANT shall prepare and provide a specifications package in accordance with
the DEPARTMENTS Handbook for the Preparation of Specification Packages and
3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-26
STAGE I FPID(S): 999999-1-52-01
[DATE]

associated training. The CONSULTANT shall provide the DEPARTMENT names of at least
two team members who have successfully completed the Specifications Package Preparation
Training and will be responsible for preparing the Specifications Package for the project.
The Specifications Package shall be prepared using the DEPARTMENT's Specs on the Web
application. The CONSULTANT shall be able to document that the procedure defined in the
Handbook for the Preparation of Specifications Packages is followed, which includes the
quality assurance/quality control procedures. The specifications package shall address all
items and areas of work and include any Mandatory Specifications, Modified Special
Provisions, and Technical Special Provisions.

The specifications package must be submitted for review to the District Specifications
Office at least 30 days prior to the contract package to Tallahassee or District due date, or
sooner if required by the District Specifications Office. This submittal does not require
signing and sealing and shall be coordinated through the Districts Project Manager. The
CONSULTANT shall coordinate with the DEPARTMENT on the submittal requirements,
but at a minimum shall consist of (1) the complete specifications package, (2) a copy of the
marked-up workbook used to prepare the package, and (3) a copy of the final project plans.

Final submittal of the specifications package must occur at least 10 working days prior to the
contract package to Tallahassee due date. This submittal shall be digitally signed, dated, and
sealed in accordance with applicable Florida Statutes.

3.4 Contract Maintenance and Electronic Document Management System (EDMS)

Contract maintenance includes project management effort for complete setup and
maintenance of files, electronic folders and documents, developing technical monthly
progress reports and schedule updates.

3.5 Value Engineering (Multi-Discipline Team) Review

The design for this project will be subjected to a Value Engineering (VE) review or N/A.
The VE review will be conducted by a multi-disciplined independent team of
DEPARTMENT and CONSULTANT personnel for the purpose of the improving the value
of the project.

The CONSULTANT shall develop the design and contract documents using sound value
engineering practices to the fullest extent possible, in order to support appropriate design
decisions in producing the contract plans for the most efficient and economical design.

Value Engineering is an event-related activity and should occur at a time when it will
provide the greatest opportunity for value improvement, as determined by the Department
Project Manager and Value Engineering Coordinator. This opportune time during the design
phase of a project will generally fall between completion of Phase I design plans and
completion of Phase II design plans, but may occur at any time during the development of a
project.

Activities required by the CONSULTANT in support of the VE team are:

Providing Materials and Information: The CONSULTANT shall allow ample time for the
appropriate knowledgeable members of their staff to present current design documentation
and data to the VE team, as deemed necessary for an effective project review.
3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-27
STAGE I FPID(S): 999999-1-52-01
[DATE]

The Consultant Project Manager and other key members of the design team shall meet with
the VE team to explain the development of design features and how and why they were
selected. The information will be provided in the form of a personal verbal presentation and
the submittal of a package containing current plans and other documentation. This
presentation will take place at the location of the VE study and may be followed up with
additional meetings, written communications and phone enquiries.

Information and data that should be available to the VE Team include, but is not limited to
the following:

One copy of all environmental documents


One copy of the Preliminary Engineering Report
Three copies of all plan drawings
Drainage alternatives information
One copy of Bridge Development Reports
One copy of Pavement Type Selection Report
One copy of Pavement Design Package
One copy of other miscellaneous reports
Project Cost Estimate

The Project Cost Estimate shall include a tabulation of estimated construction costs for the
proposed design. This list shall, at a minimum, contain a breakdown of costs for each major
element of the design.

The CONSULTANT shall provide, in the form of a matrix, all criteria and weighted impacts
used in arriving at decisions for the selection of specific design features. These criteria must
include Safety, Operation, Maintenance and Public Acceptance.

All reports provided by the CONSULTANT will be returned after the VE review has been
completed. However copies of plans and drawings may be kept by the VE team.

3.6 Prime Consultant Project Manager Meetings

Includes only the Prime Consultant Project Manager's time for travel and attendance at
Activity Technical Meetings and other meetings listed in the meeting summary for Task 3.6
on tab 3 Project General Task of the staff hour forms. Staff hours for other personnel
attending Activity Technical Meetings are included in the meeting task for that specific
Activity.

3.7 Plans Update

The effort needed for Plans Update services will vary from project to project, depending
on size and complexity of the project, as well as the duration of time spent "on the shelf".

Specific services will be negotiated as necessary as a contract amendment.

3.8 Post Design Services

Post Design Services may include, but not limited to, meetings, construction assistance,
plans revisions, shop drawing review, survey services, as-built drawings, and load ratings.
3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-28
STAGE I FPID(S): 999999-1-52-01
[DATE]

Specific services will be negotiated at a later date as necessary as a contract amendment.

Post Design Services are not intended for instances of CONSULTANT errors and/or
omissions.

3.9 Digital Delivery

The CONSULTANT shall deliver final contract plans and documents in digital format. The
final contract plans and documents shall be digitally signed and sealed files delivered to the
DEPARTMENT on acceptable electronic media, as determined by the DEPARTMENT.

3.10 Risk Assessment Workshop

This project will be subject to Risk Assessment (RA) and Management for the purpose of
the identifying, quantifying and managing the potential cost and schedule risks of the
project. The RA for this project will be managed by the Department Project Manager and
supported by a multi-disciplined team (RA Team) of DEPARTMENT and CONSULTANT
personnel and subject-matter experts (SMEs). The Department Project Manager will be the
lead for the RA Team.

There will be a Risk Assessment (RA) Workshop and workshop related meetings during the
design. The Workshop will generally occur before completion of Phase I design plans, but
may occur at any time during the development of a project as determined by the Department
Project Manager. The Department Project Manager will develop a Risk Register following
the Workshop, and utilize the Risk Register throughout the life of the project to mitigate and
manage the risks.

The CONSULTANT (and key subconsultant(s) if applicable), and other key members of the
design team will attend and participate in the Risk Assessment Workshop for this project.
This will involve a Risk Preparatory Session (half-day to 1 day plus information
assessment), a Risk Assessment Workshop (1 to 3 days), and Risk Follow-Up Meeting (half-
day to 1 day).

The CONSULTANT and other key members of the design team will attend and participate in
associated follow-up RA meetings (approximately one meeting every three to six months as
deemed necessary) with the Department Project Manager (and RA team if applicable) to
discuss the risks, mitigation strategies and any updates to the Risk Register. This includes
written communications and phone inquiries. The CONSULTANT will coordinate with
subconsultants who need to attend the Workshop and associated meetings.

CONSULTANT shall provide the RA Team meeting materials that are deemed necessary by
the Department Project Manager to conduct the Workshop and associated meetings. The
meeting materials include the following:

One copy of all environmental documents


One copy of the Preliminary Engineering Report
One copy of all plan drawings (three copies if a workshop is applicable)
Drainage alternatives information
One copy of Bridge Development Reports
One copy of Pavement Type Selection Report
One copy of Pavement Design Package
One copy of other miscellaneous reports
3 PROJECT COMMON AND PROJECT GENERAL TASKS
A-29
STAGE I FPID(S): 999999-1-52-01
[DATE]

Project Schedule
Project Cost Estimate

Project Cost Estimate shall include a tabulation of estimated construction costs for the
proposed design, and a breakdown of costs for each major element of the design, such as
Right of Way, Design, CEI, Utilities, JPA/LAP funds, etc.

The CONSULTANT shall allow ample time for the appropriate knowledgeable members of
their staff to prepare and provide current design documentation and data. All reports
provided by the CONSULTANT will be returned after the RA Workshop has been
completed; however copies of plans and drawings may be kept by the RA team. The
CONSULTANT will be responsible for providing follow-up actions as necessary.

3.11 Railroad, Transit and/or Airport Coordination

[Provide project-specific information or N/A]

3.12 Landscape and Existing Vegetation Coordination

Coordinate to ensure preservation and protection of existing vegetation. Relocation of


existing vegetation may be necessary in some cases. Space for proposed landscape should be
preserved and conflicts with drainage, utilities, ITS, and signage should be minimized.
Coordination with the District Landscape Architect may be necessary as defined in 4.12.
Additionally, coordination with the Florida Scenic Highways program should be included to
ensure any requirements of the FSH program are met.

3.13 Other Project General Tasks

[Describe other project general tasks or N/A]

3 PROJECT COMMON AND PROJECT GENERAL TASKS


A-30
STAGE I FPID(S): 999999-1-52-01
[DATE]

4 ROADWAY ANALYSIS

The CONSULTANT shall analyze and document Roadway Tasks in accordance with all
applicable manuals, guidelines, standards, handbooks, procedures, and current design
memorandums.

4.1 Typical Section Package

The CONSULTANT shall provide an approved Typical Section Package prior to the first
plans submittal.

4.2 Pavement Type Selection Report

Pavement Type Selection Reports are required for every project one mile or greater in length
where work includes a modification to the base materials. The Pavement Type Selection
decision will again be reviewed by FDOT Design at the time the pavement is designed to
warrant reconsideration. A letter to the Project Design File documenting the pavement type
decision is required, even if no report is performed.

4.3 Pavement Design Package

The CONSULTANT shall provide an approved Pavement Design Package prior to the Phase
II plans submittal date.

4.4 Cross-Slope Correction

The CONSULTANT shall coordinate with the DEPARTMENT to obtain existing cross slope
data, determine roadway limits where cross slope is potentially out of tolerance and
determine a resolution [or N/A].

4.5 Horizontal/Vertical Master Design Files

The CONSULTANT shall design the geometrics using the design standards that are most
appropriate with proper consideration given to the design traffic volumes, design speed,
capacity and levels of service, functional classification, adjacent land use, design
consistency and driver expectancy, aesthetics, existing vegetation to be preserved, pedestrian
and bicycle concerns, ADA requirements, Safe Mobility For Life Program, access
management, PD&E documents and scope of work. The CONSULTANT shall also develop
utility conflict information to be provided to project Utility Coordinator in the format
requested by the DEPARTMENT, and shall review Utility Work Schedules.

Note: When the project includes a 3D Model deliverable, also include Activity 36
3D Modeling.

4.6 Access Management

The CONSULTANT shall incorporate access management standards for each project in
coordination with DEPARTMENT staff. The CONSULTANT shall review adopted access
management standards and the existing access conditions (interchange spacing, signalized

4 ROADWAY ANALYSIS
A-31
STAGE I FPID(S): 999999-1-52-01
[DATE]

intersection spacing, median opening spacing, and connection spacing). Median openings
that will be closed, relocated, or substantially altered shall be shown on plan sheets and
submitted with supporting documentation for review with the first plans submittal.

The DEPARTMENT shall provide access management classification information and


information derived from PD&E studies and public hearings to be used by the
CONSULTANT.

4.7 Roundabout Evaluation

The CONSULTANT shall analyze and document Roundabout Evaluation Tasks in


accordance with all applicable manuals, guidelines, standards, handbooks, procedures, and
current design memorandums.

The CONSULTANT shall perform a Roundabout Screening for assessment of potential site
impacts such as utility adjustments or relocations, right-of-way takes, environmental
mitigation, and access management.

The CONSULTANT shall perform a Roundabout b/c Evaluation comparing a roundabout


with a traditional intersection (stop controlled or signal controlled). The b/c analysis
considers safety benefits associated with reduced crashes, delay, life cycle costs including
right-of-way, utilities, construction, operation, and maintenance.

The CONSULTANT shall perform a Geometric and Operation Analysis to establish the
roundabout alignment, geometry and lane requirements. Roundabout geometric and
operational analysis must be documented in a preliminary report including data collection,
conceptual layout, crash analysis, traffic counts, traffic forecast, and future design and
opening year analysis.

The CONSULTANT shall perform all efforts required for traffic data collection and required
design elements for all the above steps accordingly, including crash reports, 24 hour machine
counts, peak hour turning movement counts, existing geometrics, pedestrian and bicycle
volumes, posted speed limits, delay counts, design vehicle, access management, transit
operations and physical and right of way limitations.

4.8 Roundabout Final Design Analysis

The CONSULTANT shall finalize the design of the roundabout in accordance with all
applicable manuals, guidelines, standards, handbooks, procedures, and current design
memorandums.

The CONSULTANT shall perform a final roundabout operational analysis that recommends
a functional geometric layout that is cost effective, safe and meets the needs of the
community. A final roundabout design will be recommended for implementation, and all
geometric and operational analysis will be documented in a final roundabout report.

4.9 Cross Section Design Files

The CONSULTANT shall establish and develop cross section design files in accordance
with the DEPARTMENTs CADD manual.

Note: If the Cross Sections are prepared using a 3D model, use Task 36.5 instead of

4 ROADWAY ANALYSIS
A-32
STAGE I FPID(S): 999999-1-52-01
[DATE]

Task 4.9 for the Cross Section Design Files.

4.10 Traffic Control Analysis

The CONSULTANT shall design a safe and effective Traffic Control Plan to move vehicular
and pedestrian traffic during all phases of construction. The design shall include construction
phasing of roadways ingress and egress to existing property owners and businesses, routing,
signing and pavement markings, and detour quantity tabulations, roadway pavement,
drainage structures, ditches, front slopes, back slopes, drop offs within clear zone, and traffic
monitoring sites. Special consideration shall be given to the construction of the drainage
system when developing the construction phases. Positive drainage must be maintained at all
times. The design shall include construction phasing of roadways to accommodate the
construction or relocation of utilities when the contract includes Joint Project Agreements
(JPAs).

The CONSULTANT shall investigate the need for temporary traffic signals, temporary
lighting, alternate detour roads, and the use of materials such as sheet piling in the analysis.
The Traffic Control Plan shall be prepared by a certified designer who has completed
training as required by the DEPARTMENT. Before proceeding with the Traffic Control Plan,
the CONSULTANT shall meet with the appropriate DEPARTMENT personnel. The purpose
of this meeting is to provide information to the CONSULTANT that will better coordinate
the Preliminary and Final Traffic Control Plan efforts.

The CONSULTANT shall consider the local impact of any lane closures or alternate routes.
When the need to close a road is identified during this analysis, the CONSULTANT shall
notify the DEPARTMENT's Project Manager as soon as possible. Proposed road closings
must be reviewed and approved by the DEPARTMENT. Diligence shall be used to
minimize negative impacts by appropriate specifications, recommendations or plans
development. Local impacts to consider will be local events, holidays, peak seasons, detour
route deterioration and other eventualities. CONSULTANT shall be responsible to obtain
local authorities permission for use of detour routes not on state highways.

4.11 Master TCP Design Files

The CONSULTANT shall develop master Traffic Control Plan (TCP) files (for Level II and
Level III only) showing each phase of the Traffic Control Plan.

4.12 Selective Clearing and Grubbing

a. Selective Clearing and Grubbing of Existing Vegetation Field Assessment

The CONSULTANT shall review information from the DEPARTMENT and conduct a
project field assessments(s) of existing vegetation. At least one field assessment visit is to
be attended by the District Landscape Architect.
The Result of the Field Assessments(s) will determine the course of action for Selective
Clearing and Grubbing and the extent of the Vegetation Survey under Task 2.10.

b. Selective Clearing and Grubbing Site Inventory Analysis of Existing


Vegetation and Cross-Discipline Coordination (OPTIONAL SERVICES)

4 ROADWAY ANALYSIS
A-33
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall coordinate with utility companies, drainage engineers, and traffic
engineers to ensure that preservation of existing vegetation is coordinated between all
disciplines. Coordinate with the District Landscape Architect.

Based on the field assessment, the CONSULTANT may be required do a site inventory
analysis of existing vegetation, opportunities for preservation and protection of existing
vegetation, relocation options, and selective removal of nuisance and/or non-nuisance
vegetation. Coordinate with surveyor to have trees tagged and surveyed, as necessary.

c. Selective Clearing and Grubbing- Existing Vegetation Maintenance Report

The CONSULTANT shall include in the plans instructions for the care and maintenance of
the tree preservation areas, and selective clearing and grubbing areas throughout the
construction period. The CONSULTANT will coordinate with the District Landscape
Architect to ensure that the intent of the tree preservation areas is in alignment with future
highway landscape plans. It is understood the contractor will be responsible for coordination
with an arborist for the care of vegetation during construction and during root and branch
pruning, however, the CONSULTANT should be knowledgeable in arboricultural practices
to the extent that they are able to deliver detailed and informed Selective Clearing and
Grubbing Plans.

4.13 Tree Disposition Plans

Consultant will prepare a Tree Disposition Plan outlining the requirements for the removal,
relocation, and remaining trees located within the project boundaries. Will utilize the
information collected from the Vegetation Survey and information collected under task 4.12
for Selective Clearing and Grubbing.

4.14 Design Variations and Exceptions

If available, the DEPARTMENT shall furnish the Variation/Exception Report. The


CONSULTANT shall prepare the documentation necessary to gain DEPARTMENT approval
of all appropriate Design Variations and/or Design Exceptions before the first submittal.

4.15 Design Report

The CONSULTANT shall prepare all applicable report(s) as listed in the Project Description
section of this scope.

The CONSULTANT shall submit to the DEPARTMENT design notes, data, and calculations
to document the design conclusions reached during the development of the contract plans.

The design notes, data, and computations shall be recorded on size 8"x11" sheets, fully
titled, numbered, dated, indexed and signed by the designer and the checker. Computer
output forms and other oversized sheets shall be folded to 8"x11" size. The data shall be in
a hardback folder for submittal to the DEPARTMENT.

4.16 Quantities

The CONSULTANT shall develop accurate quantities and the supporting documentation,
including construction days when required.

4 ROADWAY ANALYSIS
A-34
STAGE I FPID(S): 999999-1-52-01
[DATE]

4.17 Cost Estimate

4.18 Technical Special Provisions

4.19 Other Roadway Analyses

4.20 Field Reviews

4.21 Monitor Existing Structures

The CONSULTANT shall perform field observations to visually identify existing structures
within the project limits which may require settlement, vibration or groundwater monitoring
by the contractor during construction in accordance with PPM Volume I Chapter 34. The
CONSULTANT shall identify the necessary pay items to be included in the bid documents
to monitor existing structures.

Optional Services (may be negotiated at a later date if needed): The CONSULTANT shall
coordinate with and assist the geotechnical engineer and/or structural engineer to develop
mitigation strategies (when applicable).

4.22 Technical Meetings

4.23 Quality Assurance/Quality Control

4.24 Independent Peer Review

4.25 Supervision

4.26 Coordination

4 ROADWAY ANALYSIS
A-35
STAGE I FPID(S): 999999-1-52-01
[DATE]

5 ROADWAY PLANS

The CONSULTANT shall prepare Roadway, Traffic Control, Utility Adjustment Sheets, plan
sheets, notes, and details. The plans shall include the following sheets necessary to convey
the intent and scope of the project for the purposes of construction.

5.1 Key Sheet

5.2 Summary of Pay Items Including Quantity Input

5.3 Typical Section Sheets

5.3.1 Typical Sections

5.3.2 Typical Section Details

5.4 General Notes/Pay Item Notes

5.5 Summary of Quantities Sheets

5.6 Project Layout

5.7 Plan/Profile Sheet

5.8 Profile Sheet

5.9 Plan Sheet

5.10 Special Profile

5.11 Back-of-Sidewalk Profile Sheet

5.12 Interchange Layout Sheet

5.13 Ramp Terminal Details (Plan View)

5.14 Intersection Layout Details

5.15 Special Details

5.16 Cross-Section Pattern Sheet(s)

5.17 Roadway Soil Survey Sheet(s)

5.18 Cross Sections

5.19 Temporary Traffic Control Plan Sheets

5 ROADWAY PLANS
A-36
STAGE I FPID(S): 999999-1-52-01
[DATE]

5.20 Temporary Traffic Control Cross Section Sheets

5.21 Temporary Traffic Control Detail Sheets

5.22 Utility Adjustment Sheets

5.23 Selective Clearing and Grubbing Sheet(s)

5.23.1 Selective Clearing and Grubbing

5.23.2 Selective Clearing and Grubbing Details

5.24 Tree Disposition Plan Sheet(s)

5.24.1 Tree Disposition Plan Sheet(s)

5.24.2 Tree Disposition Plan Tables and Schedules

5.25 Project Network Control Sheet(s)

5.26 Environmental Detail Sheets

Preparation of detail sheets for potential environmental issues such as, underground fuel
tanks and monitoring wells, septic tanks within the proposed right of way. All piping and
pumps in association with the above referenced issues shall also be located and identified by
the survey. The CONSULTANT shall relay to the DEPARTMENT any findings of
contaminated soil, monitoring wells, or any features (particularly springs or sinks) relating to
contamination or hazardous material.

Coordination with Permits/Environmental staff and preparing Dredge & Fill Detail sheets
where applicable.

5.26 Utility Verification Sheet(s) (SUE Data)

5.28 Quality Assurance/Quality Control

5.29 Supervision

5 ROADWAY PLANS
A-37
STAGE I FPID(S): 999999-1-52-01
[DATE]

6a DRAINAGE ANALYSIS

The CONSULTANT shall analyze and document Drainage Tasks in accordance with all
applicable manuals, guidelines, standards, handbooks, procedures, and current design
memorandums.

The CONSULTANT shall be responsible for designing a drainage and stormwater


management system. All design work shall comply with the requirements of the appropriate
regulatory agencies and the DEPARTMENTs Drainage Manual.

The CONSULTANT shall coordinate fully with the appropriate permitting agencies and the
DEPARTMENTs staff. All activities and submittals should be coordinated through the
DEPARTMENTs Project Manager. The work will include the engineering analyses for any
or all of the following:

6a.1 Drainage Map Hydrology

Accurately delineate drainage basin boundaries to be used in defining the system hydrology.
Basin delineation shall incorporate existing survey and/or LiDAR and shall be
supplemented, as necessary, with other appropriate data sources (such as permitted site
plans) and field observations. Basin delineations shall also include any existing collection
systems in a logical manner to aid in the development of the hydraulic model. Prepare the
Drainage Maps in accordance with the Plans Preparation Manual.

6a.2 Base Clearance Report

Analyze, determine, and document high water elevations per basin which will be used to set
roadway profile grade and roadway materials. Determine surface water elevations at cross
drains, floodplains, outfalls and adjacent stormwater ponds. Determine groundwater
elevations at intervals between the above-mentioned surface waters. Document findings in a
Base Clearance Report.

6a.3 Pond Siting Analysis and Report

Evaluate pond sites using a preliminary hydrologic analysis. Document the results and
coordination for all of the project's pond site analyses. The Drainage Manual provides
specific documentation requirements.

6a.4 Design of Cross Drains

Analyze the hydraulic design and performance of cross drains. Check existing cross drains
to determine if they are structurally sound and can be extended. Document the design as
required. Determine and provide flood data as required.

6a.5 Design of Ditches

Design roadway conveyance and outfall ditches. This task includes capacity calculations,
longitudinal grade adjustments, flow changes, additional adjustments for ditch
convergences, selection of suitable channel lining, design of side drain pipes, and
6 DRAINAGE ANALYSIS
A-38
STAGE I FPID(S): 999999-1-52-01
[DATE]

documentation. (Design of linear stormwater management facilities in separate task.)

6a.6 Design of Stormwater Management Facility (Offsite or Infield Pond)

Design stormwater management facilities to meet requirements for stormwater quality


treatment, attenuation and aesthetics. Develop proposed pond layout (contributing drainage
basin, shape, contours, slopes, volumes, tie-ins, etc.), perform routing, pollutant loading
calculations, recovery calculations, design the outlet control structure and buoyancy
calculations for pond liners when necessary.

6a.7 Design of Stormwater Management Facility (Roadside Ditch as Linear Pond)

Design stormwater management facilities to meet requirements for stormwater quality


treatment, attenuation and aesthetics. Develop proposed pond layout (contributing drainage
basin, shape, contours, slopes, volumes, tie-ins, etc.), perform routing, pollutant loading
calculations, recovery calculations and design the outlet control structure.

6a.8 Design of Floodplain Compensation

Determine floodplain encroachments, coordinate with regulatory agencies, and develop


proposed compensation area layout (shape, contours, slopes, volumes, etc.). Document the
design following the requirements of the regulatory agency.

6a.9 Design of Storm Drains

Develop a working drainage map, determine runoff, inlet locations, and spread. Calculate
hydraulic losses (friction, utility conflict and, if necessary, minor losses). Determine design
tailwater and, if necessary, outlet scour protection.

6a.10 Optional Culvert Material

Determine acceptable options for pipe materials using the Culvert Service Life Estimator.

6a.11 French Drain Systems

Design French Drain Systems to provide stormwater treatment and attenuation. Identify
location for percolation tests and review these, determine the size and length of French
Drains, design the control structure/weir, and model the system of inlets, conveyances,
French Drains, and other outfalls using a routing program.

6a.12 Drainage Wells

Design the discharge into deep wells to comply with regulatory requirements. Identify the
location of the well, design the control structure/weir, and model the system using a routing
program.

6a.13 Drainage Design Documentation Report

Compile drainage design documentation into report format. Include documentation for all
the drainage design tasks and associated meetings and decisions, except for stand-alone
reports, such as the Pond Siting Analysis Report and Bridge Hydraulics Report.

6 DRAINAGE ANALYSIS
A-39
STAGE I FPID(S): 999999-1-52-01
[DATE]

6a.14 Bridge Hydraulic Report

Calculate hydrology, hydraulics, deck drainage, scour, and appropriate counter measures.
Prepare report and the information for the Bridge Hydraulics Recommendation Sheet.

6a.15 Temporary Drainage Analysis

Evaluate and address drainage to adequately drain the road and maintain existing offsite
drainage during all construction phases. Provide documentation.

6a.16 Cost Estimate

6a.17 Technical Special Provisions

6a.18 Other Drainage Analysis

6a.19 Field Reviews

6a.20 Technical Meetings

6a.21 Environmental Look-Around Meetings

6a.22 Quality Assurance/Quality Control

6a.23 Independent Peer Review

6a.24 Supervision

6a.25 Coordination

6 DRAINAGE ANALYSIS
A-40
STAGE I FPID(S): 999999-1-52-01
[DATE]

6b DRAINAGE PLANS

The CONSULTANT shall prepare Drainage plan sheets, notes, and details. The plans shall
include the following sheets necessary to convey the intent and scope of the project for the
purposes of construction.

6b.1 Drainage Map (Including Interchanges)

6b.2 Bridge Hydraulics Recommendation Sheets

6b.3 Summary of Drainage Structures

6b.4 Optional Pipe/Culvert Material

6b.5 Drainage Structure Sheet(s) (Per Structure)

6b.6 Miscellaneous Drainage Detail Sheets

6b.7 Lateral Ditch Plan/Profile

6b.8 Lateral Ditch Cross Sections

6b.9 Retention/Detention Pond Detail Sheet(s)

6b.10 Retention Pond Cross Sections

6b.11 Erosion Control Plan Sheet(s)

6b.12 SWPPP Sheet(s)

6b.13 Quality Assurance/Quality Control

6b.14 Supervision

7 UTILITIES
A-41
STAGE I FPID(S): 999999-1-52-01
[DATE]

7 UTILITIES

The CONSULTANT shall identify utility facilities and secure agreements, utility work
schedules, and plans from the Utility Agency Owners (UAO) ensuring all conflicts that exist
between utility facilities and the DEPARTMENTs construction project are addressed. The
CONSULTANT shall certify all utility negotiations have been completed and that
arrangements have been made for utility work to be undertaken.

7.1 Utility Kickoff Meeting

Before any contact with the UAO(s), the CONSULTANT shall meet with the District Utility
Office (DUO) to receive guidance, as may be required, to assure that all necessary
coordination will be accomplished in accordance with DEPARTMENT procedures.
CONSULTANT shall bring a copy of the design project work schedule reflecting utility
activities.

7.2 Identify Existing Utility Agency Owner(s)

The Consultant shall identify all utilities within and adjacent to the project limits that may be
impacted by the project.

7.3 Make Utility Contacts

First Contact: The CONSULTANT shall send letters and two sets of plans to each utility, one
set for the utility office, and one set to the DEPARTMENT Offices as required by the
District. Includes contact by phone for meeting coordination. Request type, size, location,
easements, and cost for relocation if reimbursement is claimed. Request the voltage level for
power lines in the project area. Send UAO requests for reimbursement to FDOT for a legal
opinion. Include the meeting schedule (if applicable) and the design schedule. Include
typical meeting agenda. If scheduling a meeting, give 4 weeks advance notice.

Second Contact: At a minimum of 4 weeks prior to the meeting, the CONSULTANT shall
transmit two complete sets of Phase II plans and the utility conflict information (when
applicable and in the format requested by the DEPARTMENT) to each UAO having
facilities located within the project limits, and one set to the DEPARTMENT Offices as
required by the District.

Third Contact: Identify agreements and assemble packages. The CONSULTANT shall send
agreements, letters, the utility conflict information (when applicable and in the format
requested by the DEPARTMENT) and two sets of plans to the UAO(s) including all
component sets, one set for the utility office, one set to construction and maintenance if
required. Include the design schedule.

Not all projects will have all contacts as described above.

7.4 Exception Processing

The CONSULTANT shall be responsible for transmitting/coordinating the appropriate


design reports including, but not limited to, the Resurfacing, Restoration and Rehabilitation
(RRR) report, Preliminary Engineering Report, Project Scope and/or the Concept Report (if
7 UTILITIES
A-42
STAGE I FPID(S): 999999-1-52-01
[DATE]

applicable) to each UAO to identify any condition that may require a Utility Exception. The
CONSULTANT shall identify and communicate to the UAO any facilities in conflict with
their location or project schedule. The CONSULTANT shall assist with the processing of
design exceptions involving Utilities with the UAO and the DEPARTMENT. Assist with
processing per the UAM.

7.5 Preliminary Utility Meeting

The CONSULTANT shall schedule (time and place), notify participants, and conduct a
preliminary utility meeting with all UAO(s) having facilities located within the project limits
for the purpose of presenting the project, review the current design schedule, evaluate the
utility information collected, provide follow-up information on compensable property rights
from the FDOT Legal Office, discuss the utility work by highway contractor option with
each utility, and discuss any future design issues that may impact utilities. This is also an
opportunity for the UAO(s) to present proposed facilities. The CONSULTANT shall keep
accurate minutes and distribute a copy to all attendees.

7.6 Individual/Field Meetings

The CONSULTANT shall meet with each UAO as necessary, separately or together,
throughout the project design duration to provide guidance in the interpretation of plans,
review changes to the plans and schedules, standard or selective clearing and grubbing work,
and assist in the development of the UAO(s) plans and work schedules. The CONSULTANT
is responsible for motivating the UAO to complete and return the necessary documents after
each Utility Contact or Meeting.

7.7 Collect and Review Plans and Data from UAO(s)

The CONSULTANT shall review utility marked plans and data individually as they are
received for content. Ensure information from the UAO (utility type, material and size) is
sent to the designer for inclusion in the plans. Forward all requests for utility reimbursement
and supporting documentation to the DUO.

7.8 Subordination of Easements Coordination

The CONSULTANT, if requested by the DEPARTMENT, shall transmit to and secure from
the UAO the executed subordination agreements prepared by the appropriate
DEPARTMENT office. The CONSULTANT shall coordinate with the DUO the
programming of the necessary work program funds to compensate the UAO.

7.9 Utility Design Meeting

The CONSULTANT shall schedule (time and place), notify participants, and conduct a
Utility meeting with all affected UAO(s). The CONSULTANT shall be prepared to discuss
impacts to existing trees/vegetation and proposed landscape, drainage, traffic signalization,
maintenance of traffic (construction phasing), review the current design schedule and letting
date, evaluate the utility information collected, provide follow-up information on
compensable property rights from FDOT Legal Office, discuss with each UAO the utility
work by highway contractor option, discuss any future design issues that may impact
utilities, etc., to the extent that they may have an effect on existing or proposed utility
facilities with particular emphasis on drainage and maintenance of traffic with each UAO.
The intent of this meeting shall be to assist the UAOs in identifying and resolving conflicts

7 UTILITIES
A-43
STAGE I FPID(S): 999999-1-52-01
[DATE]

between utilities and proposed construction before completion of the plans, including utility
adjustment details. Also to work with the UAOs to recommend potential resolution between
known utility conflicts with proposed construction plans as may be deemed practical by the
UAO. The CONSULTANT shall keep accurate minutes of all meetings and distribute a copy
to all attendees within 3 days. See Task 4.5 (Horizontal/Vertical Master Design File) and
Task 4.9 (Cross Section Design Files) for utility conflict location identification and
adjustments.

7.10 Review Utility Markups & Work Schedules and Processing of Schedules &
Agreements

The CONSULTANT shall review utility marked up plans and work schedules as they are
received for content and coordinate review with the designer. Send color markups and
schedules to the appropriate DEPARTMENT office(s) such as survey, geotechnical,
drainage, structures, lighting, roadway, signals, utilities, landscape architecture,
municipalities, maintaining agency, and District Traffic Operations for review and comment
if required by the District. Coordinate with the District for execution. Distribute Executed
Final Documents. Prepare Work Order for UAO(s). The CONSULTANT shall coordinate
with the DUO the programming of necessary Work Program funds.

7.11 Utility Coordination/Follow-up

The CONSULTANT shall provide utility coordination and follow up. This includes follow-
up, interpreting plans, and assisting the UAOs with completion of their work schedules and
agreements. Includes phone calls, face-to-face meetings, etc., to motivate and ensure the
UAO(s) complete and return the required documents in accordance with the project
schedule. Ensure the resolution of all known conflicts. The CONSULTANT shall keep
accurate minutes of all meetings and distribute a copy to all attendees. This task can be
applied to all phases of the project.

7.12 Utility Constructability Review

The CONSULTANT shall review utility schedules against construction contract time, and
phasing for compatibility. Coordinate with and obtain written concurrence from the
construction office. See Task 4.9 (Cross Section Design Files) for utility conflict
identification and adjustments.

7.13 Additional Utility Services

The CONSULTANT shall provide additional utility services. Additional services will be
determined when the services are required and requested. This item is not usually included
in the scope at the time of negotiation. It is normally added as a supplemental agreement
when the need is identified.

7.14 Processing Utility Work by Highway Contractor (UWHC)

This includes coordination of utility design effort between the DEPARTMENT and the
UAO(s). The CONSULTANT shall conduct additional coordination meetings, prepare and
process the agreements, review tabulation of quantities, perform UWHC constructability and
bidability review, review pay items, cost estimates and Technical Special Provisions (TSP)
prepared by the UAO. This does not include utility the utility design effort. This item is not
usually included in the scope at the time of negotiation. It is normally added as a

7 UTILITIES
A-44
STAGE I FPID(S): 999999-1-52-01
[DATE]

supplemental agreement when the need is identified. Effort for the EOR is not included in
this task, see Roadway Analysis Task Group 4.

7.15 Contract Plans to UAO(s)

If requested by the District, the CONSULTANT shall transmit the contract plans as
processed for letting to the UAO(s). Transmittals to UAO(s) may be by certified mail, return
receipt requested.

7.16 Certification/Close-Out

This includes hours for transmitting utility files to the DUO and preparation of the Utility
Certification Letter. The CONSULTANT shall certify to the appropriate DEPARTMENT
representative the following:

All utility negotiations (Full execution of each agreement, approved Utility Work Schedules,
technical special provisions written, etc.) have been completed with arrangements made for
utility work to be undertaken and completed as required for proper coordination with the
physical construction schedule.

OR

An on-site inspection was made and no utility work will be involved.

OR

Plans were sent to the Utility Companies/Agencies and no utility work is required.

7.17 Other Utilities

The CONSULTANT shall provide other utility services. This includes all efforts for a utility
task not covered by an existing defined task. Required work will be defined in the scope and
negotiated on a case-by-case basis.

7 UTILITIES
A-45
STAGE I FPID(S): 999999-1-52-01
[DATE]

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES

The CONSULTANT shall notify the DEPARTMENT Project Manager, Environmental


Permit Coordinator and other appropriate DEPARTMENT personnel in advance of all
scheduled meetings with the regulatory agencies to allow a DEPARTMENT representative
to attend. The CONSULTANT shall copy in the Project Manager and the Environmental
Permit Coordinator on all permit related correspondence and meetings.

8.1 Preliminary Project Research

The CONSULTANT shall perform preliminary project research and shall be responsible for
regulatory agency coordination to assure that design efforts are properly directed toward
permit requirements. The research shall include a review of the projects PD&E documents
including but not limited to the Environmental Document, Wetland Evaluation Report,
Endangered Species and Biological Assessment and Essential Fish and Habitat Report.

The CONSULTANT shall also review for any existing easements or other restrictions that
may exist both within or proposed project boundary. The CONSULTANT shall determine if
any Sovereign Submerged Lands easements need to modified or acquired. Project research
may include but should not be limited to review of available federal, state, and local permit
files and databases, local government information including county and property appraiser
data. This information will be shown on the plans as appropriate.

8.2 Field Work

8.2.1 Pond Site Alternatives:


The CONSULTANT shall review alternative pond sites as directed by the DEPARTMENT.

8.2.2 Establish Wetland Jurisdictional Lines and Assessments:


The CONSULTANT shall collect all data and information necessary to determine the
boundaries of wetlands and other surface waters defined by the rules or regulations of each
agency processing or reviewing a permit application necessary to construct the
DEPARTMENT project.

The CONSULTANT shall be responsible for, but not limited to, the following activities:

Determine landward extent of wetlands and other surface waters as defined in Rule
Chapter 62-340, F.A.C. as ratified in Section 373.4211, F.S.
Determine the jurisdictional boundaries and obtain a jurisdictional determination of
wetlands and other surface waters as defined by rules or regulations of any permitting
authority that is processing a DEPARTMENT permit application.
Prepare aerial maps showing the jurisdictional boundaries of wetlands and surface
waters. Aerial maps shall be reproducible, of a scale no greater than 1=200 and be
recent photography. The maps shall show the jurisdictional limits of each agency. Photo
copies of aerials are not acceptable. All jurisdictional boundaries are to be tied to the
projects baseline of survey. When necessary, a wetland specific survey will be
prepared by a registered surveyor and mapper.
Prepare a written assessment of the current condition and functional value of the
wetlands and other surface waters. Prepare data in tabular form which includes the ID

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES


A-46
STAGE I FPID(S): 999999-1-52-01
[DATE]

number for each wetland impacted, size of wetland to be impacted, type of impact and
identify any wetland within the project limits that will not be impacted by the project.
Prepare appropriate Agency Forms to obtain required permits Forms may include but
are not limited to the United States Army Corps of Engineers (USACE) Wetland
Determination Data Form Atlantic and Gulf Coastal Plain Region; the USACE
Approved Jurisdictional Determination Form; Uniform Mitigation Assessment
Method forms and/or project specific data forms.
8.2.3 Species Surveys:
The CONSULTANT shall conduct wildlife surveys as defined by rules or regulations of any
permitting authority that is processing a DEPARTMENT permit.

8.2.4 Archaeological Surveys:


The CONSULTANT shall conduct Archaeological field surveys as required, in accordance
with Part 2, Chapter 12 of the PD&E Manual.

8.3 Agency Verification of Wetland Data

The CONSULTANT shall be responsible for verification of wetland data identified in


Section 8.2 and coordinating regulatory agency field reviews, including finalization of
wetland assessments and jurisdictional determinations with applicable agencies.

8.4 Complete and Submit All Required Permit Applications

The CONSULTANT shall prepare permit application packages as identified in the Project
Description section. The permit application package must be approved by the
DEPARTMENT prior to submittal to the regulatory agency.

The CONSULTANT shall collect all of the data and information necessary to obtain the
environmental permits required to construct the project. The CONSULTANT shall prepare
each permit application for DEPARTMENT approval in accordance with the rules and/or
regulations of the environmental agency responsible for issuing a specific permit and/or
authorization to perform work.

The CONSULTANT will submit all permit applications, as directed by the DEPARTMENT,
and be responsible for payment of all permit fees.

Local Permits:

[List Particulars here]

8.5 Prepare Dredge and Fill Sketches (as needed)

8.6 Prepare USCG Permit

8.7 Prepare Water Management District Right of Way Occupancy Permit

8.8 Prepare Coastal Construction Control Line (CCCL) Permit Application (as
needed)

If a CCCL Permit is required, the CONSULTANT shall be responsible for the


preparation of the legal advertisement required to acquire the final Notice to
8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES
A-47
STAGE I FPID(S): 999999-1-52-01
[DATE]

Proceed authorization for the Florida Department of Environmental Protection


(FDEP). Legal advertisements shall be published one time in a newspaper that meets
the notification requirements of the FDEP.

8.9 Prepare Tree Permit Information (as needed)

8.10 Mitigation Design

If wetland impacts cannot be avoided, the CONSULTANT shall prepare a mitigation plan to
be included as a part of the Environmental Resource Permit and or Section 404 permit
applications.

Prior to the development of alternatives, the CONSULTANT shall meet with the Project
Manager to determine the DEPARTMENTs policies in proposing mitigation. The
CONSULTANT shall proceed in the development of a mitigation plan based upon the
general guidelines provided by the DEPARTMENT.

The CONSULTANT will be directed by the DEPARTMENT to investigate the mitigation


options that meet federal and state requirements in accordance with section 373.4137, F.S.
Below are mitigation options:

Payment to DEP/WMD for mitigation services as defined in Section 373.4137,


F.S.
Monetary participation in offsite regional mitigation plans
Purchase of mitigation credits from a mitigation bank
Creation/restoration on public lands
Creation/restoration on right of way purchased by the DEPARTMENT
Creation/restoration on existing DEPARTMENT right of way
In the event that physical creation or restoration is the only feasible alternative to offset
wetland impacts, the CONSULTANT shall collect all of the data and information necessary
to prepare alternative mitigation plans that may be acceptable to all permitting agencies and
commenting agencies who are processing or reviewing a permit application for a
DEPARTMENT project.

Prior to selection of a final mitigation site, the CONSULTANT will provide the following
services in the development of alternative mitigation plans:

Preliminary jurisdictional determination for each proposed site


Selection of alternative sites
Coordination of alternative sites with the DEPARTMENT/all environmental
agencies
Written narrative listing potential sites with justifications for both recommended
and non-recommended sites.
8.11 Mitigation Coordination and Meetings

The CONSULTANT shall coordinate with DEPARTMENT personnel prior to approaching


any environmental permitting or reviewing agencies. Once a mitigation plan has been
reviewed and approved by the DEPARTMENT, the CONSULTANT will be responsible for
coordinating the proposed mitigation plan with the environmental agencies.

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES


A-48
STAGE I FPID(S): 999999-1-52-01
[DATE]

8.12 Other Environmental Permits

Environmental Clearances, Reevaluations and Technical Support

8.13 Technical Support to the DEPARTMENT for Environmental Clearances and


Re-evaluations

The CONSULTANT shall provide engineering and environmental support for the
DEPARTMENT to obtain clearances for all changes to the project after the PD&E study was
completed. These changes include but are not limited to pond and/or mitigation sites
identified, land use or environmental changes, and significant design changes.

8.13.1 NEPA or SEIR Reevaluation: During the development of the final design plans, the
CONSULTANT shall be responsible for coordinating with the District Project Manager to
provide necessary engineering information required in the preparation of the reevaluation by
the DEPARTMENT. The preparation of all environmental reevaluations on major projects
include the following types of reevaluations as listed in Part 1 Chapter 13 of the
DEPARTMENTs PD&E Manual: Preliminary Engineering, Right of Way, Design Change,
and Construction Advertisement Reevaluations.

Design Change Reevaluations will be completed in accordance with Part 1 Chapter 13 of the
PD&E Manual. A technical memorandum identifying the commitments and how they were
addressed shall be submitted to the District Project Manager by the CONSULTANT for
incorporation into the reevaluation.

It is the responsibility of the CONSULTANT to provide the District Project Manager with
engineering information on major design changes including changes in typical section,
roadway alignment, pond site selection, right of way requirements, bridge to box culvert,
drainage, and traffic volumes that may affect noise models.

8.13.2 Archaeological and Historical Features: The CONSULTANT shall provide


necessary technical information to the District's Project Manager to analyze the impacts to
all cultural and historical resources due to changes in the project.

8.13.3 Wetland Impact Analysis: The CONSULTANT shall provide necessary technical
information to the Districts Project Manager to analyze the impacts to wetlands and other
surface waters due to changes in the project.

8.13.4 Essential Fish Habitat: The CONSULTANT shall provide necessary technical
information to the Districts Project Manager to analyze the impacts to essential fish habitat
due to changes in the project.

8.13.5 Wildlife and Habitat Impact Analysis: The CONSULTANT shall provide necessary
technical information to the Districts Project Manager to analyze the impacts to all wildlife
and habitat due to changes in the project.

8.13.6 Section 7 or Section 10 Consultation: The CONSULTANT shall provide necessary


technical information to the Districts Project Manager to complete a Section 7 or Section 10
Consultation as applicable.

8.14 Preparation of Environmental Clearances and Reevaluations

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES


A-49
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall prepare reports and clearances for all the changes to the project
that occurred after the PD&E study was completed. These changes could include but are
not limited to pond and/or mitigation sites identified, land use or environmental changes,
and significant design changes.

8.14.1 NEPA or SEIR Reevaluation: During the development of the final design plans,
the CONSULTANT shall be responsible for collecting the data and preparing a Reevaluation
in accordance with Part 1, Chapter 13 of the PD&E Manual.

8.14.2 Archaeological and Historical Features: The CONSULTANT shall collect data
necessary to completely analyze the impacts, due to changes in the project or project area, to
all cultural and historic resources, and prepare a Cultural Resource Assessment Request
Package, in accordance with Part 2, Chapter 12 of the PD&E Manual.

8.14.3 Wetland Impact Analysis: The CONSULTANT shall analyze the impacts to
wetlands due to changes to the project and complete the Wetlands Evaluation Report, in
accordance with Part 2, Chapter 18 of the PD&E Manual.

8.14.4 Essential Fish Habitat: The CONSULTANT shall analyze the impacts to essential
fish habitat due to changes to the project and complete the Essential Fish Habitat Report, in
accordance with Part 2, Chapter 11 of the PD&E Manual.

8.14.5 Wildlife and Habitat Impact Analysis: The CONSULTANT shall collect data
necessary and perform an Endangered Species Biological Assessment, and analyze the
impacts to wildlife and habitat by the changes to the project, in accordance with Part 2,
Chapter 27 of the PD&E Manual.

8.14.6 Section 7 or Section 10 Consultation: The CONSULTANT shall perform the


necessary analysis to complete a Section 7 or Section 10 Consultation as applicable.

8.15 Contamination Impact Analysis

The CONSULTANT shall perform the necessary analysis to complete the Contamination
Screening Evaluation for any changes to the project and complete the Contamination
Screening Evaluation Report as described in Part 2, Chapter 22, of the PD&E Manual.

8.16 Asbestos Survey

The CONSULTANT shall secure the services of a Florida Licensed Asbestos Consultant to
perform a comprehensive Asbestos Containing Materials (ACM) survey of all bridges on the
project. The survey shall include sampling of all suspect ACM. In the event that ACM is
found on the bridge, the CONSULTANT shall prepare (in coordination with the
DEPARTMENTs District Asbestos Coordinator) plans, specifications, general notes, pay
item notes and an Operation and Maintenance (O&M) plan for any asbestos to remain in
place. The CONSULTANT shall submit four (4) hard copies and one (1) electronic copy of
the final ACM survey, and the required copies of any additional supporting documents, to
the DEPARTMENTs Project Manager and to the District Asbestos Coordinator at the time
of the Phase I submittal.

8.17 Technical Meetings

8.18 Quality Assurance/Quality Control

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES


A-50
STAGE I FPID(S): 999999-1-52-01
[DATE]

8.19 Supervision

8.20 Coordination

8 ENVIRONMENTAL PERMITS, COMPLIANCE AND CLEARANCES


A-51
STAGE I FPID(S): 999999-1-52-01
[DATE]

9 STRUCTURES - SUMMARY AND MISCELLANEOUS TASKS AND DRAWINGS

The CONSULTANT shall analyze, design, and develop contract documents for all structures
in accordance with applicable provisions as defined in Section 2.19, Provisions for Work.
Individual tasks identified in Sections 9 through 18 are defined in the Staff Hour Estimation
Handbook and within the provision defined in Section 2. 20, Provisions for Work. Contract
documents shall display economical solutions for the given conditions.

The CONSULTANT shall provide Design Documentation to the DEPARTMENT with each
submittal consisting of structural design calculations and other supporting documentation
developed during the development of the plans. The design calculations submitted shall
adequately address the complete design of all structural elements. These calculations shall
be neatly and logically presented on digital media or, at the DEPARTMENTs request, on 8
x11 paper and all sheets shall be numbered. The final design calculations shall be signed
and sealed by a Florida-licensed professional engineer. A cover sheet indexing the contents
of the calculations shall be included and the engineer shall sign and seal that sheet. All
computer programs and parameters used in the design calculations shall include sufficient
backup information to facilitate the review task.

9.1 Key Sheet and Index of Drawings


9.2 Project Layout
9.3 General Notes and Bid Item Notes
9.4 Miscellaneous Common Details
9.5 Incorporate Report of Core Borings
9.6 Existing Bridge Plans
9.7 Assemble Plan Summary Boxes and Quantities
9.8 Cost Estimate
9.9 Technical Special Provisions
9.10 Field Reviews
9.11 Technical Meetings
9.12 Quality Assurance/Quality Control
9.13 Independent Peer Review
9.14 Supervision
9.15 Coordination
9 STRUCTURES SUMMARY AND MISCELLANEOUS TASKS AND DRAWINGS

A-52
STAGE I FPID(S): 999999-1-52-01
[DATE]

10 STRUCTURES - BRIDGE DEVELOPMENT REPORT

The Consultant shall prepare a Bridge Development Report (BDR). The BDR shall be
submitted as part of the Phase I Roadway Submittal, General Requirements.

General Requirements

10.1 Bridge Geometry

10.2 Ship Impact Data Collection

10.3 Ship Impact Criteria

Superstructure Alternatives

10.4 Short-Span Concrete

10.5 Medium-Span Concrete

10.6 Long Span Concrete

10.7 Structural Steel

Foundation and Substructure Alternatives

10.8 Pier/Bent

10.9 Shallow Foundations / GRS Abutments

10.10 Deep Foundations

Movable Span

10.11 Data Collection and Design Criteria

10.12 Movable Span Geometrics and Clearances

10.13 Deck System Evaluation

10.14 Framing Plan Development

10.15 Main Girder Preliminary Design

10.16 Conceptual Span Balance/Counterweight

10.17 Support System Development

10 STRUCTURES BRIDGE DEVELOPMENT REPORT


A-53
STAGE I FPID(S): 999999-1-52-01
[DATE]

10.18 Drive Power Calculations

10.19 Drive System Development

10.20 Power and Control Development

10.21 Conceptual Pier Design

10.22 Foundation Analysis (FL PIER)

10.23 Tender Visibility Study

Other BDR Issues

10.24 Aesthetics

10.25 TCP/Staged Construction Requirements

10.26 Constructability Requirements

10.27 Load Rating for Damaged/Widened Structures

10.28 Quantity and Cost Estimates

10.29 Quantity and Cost Estimates - Movable Span

10.30 Wall Type Justification

Report Preparation

10.31 Exhibits

10.32 Exhibits - Movable Span

10.33 Report Preparation

10.34 Report Preparation - Movable Span

10.35 BDR Submittal Package

Preliminary Plans

When ONLY 30% plans are final deliverable, use Task Nos. as shown for applicable bridge
types for project Activities 12 thru 16. Staffhours to be negotiated and scaled appropriately.

10 STRUCTURES BRIDGE DEVELOPMENT REPORT


A-54
STAGE I FPID(S): 999999-1-52-01
[DATE]

11 STRUCTURES - TEMPORARY BRIDGE

The CONSULTANT shall prepare plans for Temporary Bridge(s) at the location(s) specified
in Section 2.5. The CONSULTANT shall contact FDOT Office of Maintenance to
determine the type and availability of temporary before deciding on the temporary bridge
type to be used.

General Layout Design and Plans

11.1 Overall Bridge Final Geometry

11.2 General Plan and Elevation

11.3 Miscellaneous Details

End Bent Design and Plans

11.4 End Bent Structural Design

11.5 End Bent Details

Intermediate Bent Design and Plans

11.6 Intermediate Bent Structural Design

11.7 Intermediate Bent Details

Miscellaneous Substructure Design and Plans

11.8 Foundation Layout

11 STRUCTURES TEMPORARY BRIDGE


A-55
STAGE I FPID(S): 999999-1-52-01
[DATE]

12 STRUCTURES - SHORT SPAN CONCRETE BRIDGE

The CONSULTANT shall prepare plans for Short Span Concrete Bridge(s) at the location(s)
specified in Section 2.5.

General Layout Design and Plans

12.1 Overall Bridge Final Geometry

12.2 Expansion/Contraction Analysis

12.3 General Plan and Elevation

12.4 Construction Staging

12.5 Approach Slab Plan and Details

12.6 Miscellaneous Details

End Bent Design and Plans

12.7 End Bent Geometry

12.8 End Bent Structural Design

12.9 End Bent Plan and Elevation

12.10 End Bent Details

Intermediate Bent Design and Plans

12.11 Bent Geometry

12.12 Bent Stability Analysis

12.13 Bent Structural Design

12.14 Bent Plan and Elevation

12.15 Bent Details

Miscellaneous Substructure Design and Plans

12.16 Foundation Layout

12 STRUCTURES SHORT SPAN CONCRETE BRIDGE


A-56
STAGE I FPID(S): 999999-1-52-01
[DATE]

Superstructure Design and Plans

12.17 Finish Grade Elevation Calculation

12.18 Finish Grade Elevations

Cast-In-Place Slab Bridges

12.19 Bridge Deck Design

12.20 Superstructure Plan

12.21 Superstructure Sections and Details

Prestressed Slab Unit Bridges

12.22 Prestressed Slab Unit Design

12.23 Prestressed Slab Unit Layout

12.24 Prestressed Slab Unit Details and Schedule

12.25 Deck Topping Reinforcing Layout

12.26 Superstructure Sections and Details

Reinforcing Bar Lists

12.27 Preparation of Reinforcing Bar List

Load Rating

12.28 Load Rating

12 STRUCTURES SHORT SPAN CONCRETE BRIDGE


A-57
STAGE I FPID(S): 999999-1-52-01
[DATE]

13 STRUCTURES - MEDIUM SPAN CONCRETE BRIDGE

The CONSULTANT shall prepare plans for Medium Span Concrete Bridge(s) at the
location(s) specified in Section 2.5.

General Layout Design and Plans

13.1 Overall Bridge Final Geometry

13.2 Expansion/Contraction Analysis

13.3 General Plan and Elevation

13.4 Construction Staging

13.5 Approach Slab Plan and Details

13.6 Miscellaneous Details

End Bent Design and Plans

13.7 End Bent Geometry

13.8 Wingwall Design and Geometry

13.9 End Bent Structural Design

13.10 End Bent Plan and Elevation

13.11 End Bent Details

Intermediate Bent Design and Plans

13.12 Bent Geometry

13.13 Bent Stability Analysis

13.14 Bent Structural Design

13.15 Bent Plan and Elevation

13.16 Bent Details

Pier Design and Plans

13.17 Pier Geometry

13 STRUCTURES MEDIUM SPAN CONCRETE BRIDGE


A-58
STAGE I FPID(S): 999999-1-52-01
[DATE]

13.18 Pier Stability Analysis

13.19 Pier Structural Design

13.20 Pier Plan and Elevation

13.21 Pier Details

Miscellaneous Substructure Design and Plans

13.22 Foundation Layout

Superstructure Deck Design and Plans

13.23 Finish Grade Elevation (FGE) Calculation

13.24 Finish Grade Elevations

13.25 Bridge Deck Design

13.26 Bridge Deck Reinforcing and Concrete Quantities

13.27 Diaphragm Design

13.28 Superstructure Plan

13.29 Superstructure Section

13.30 Miscellaneous Superstructure Details

Reinforcing Bar Lists

13.31 Preparation of Reinforcing Bar List

Continuous Concrete Girder Design

13.32 Section Properties

13.33 Material Properties

13.34 Construction Sequence

13.35 Tendon Layouts

13.36 Live Load Analysis

13.37 Temperature Gradient

13.38 Time Dependent Analysis

13 STRUCTURES MEDIUM SPAN CONCRETE BRIDGE


A-59
STAGE I FPID(S): 999999-1-52-01
[DATE]

13.39 Stress Summary

13.40 Ultimate Moments

13.41 Ultimate Shear

13.42 Construction Loading

13.43 Framing Plan

13.44 Girder Elevation, including Grouting Plan and Vent Locations

13.45 Girder Details

13.46 Erection Sequence

13.47 Splice Details

13.48 Girder Deflections and Camber

Simple Span Concrete Design

13.49 Prestressed Beam

13.50 Prestressed Beam Schedules

13.51 Framing Plan

Beam Stability

13.52 Beam/Girder Stability

Bearing

13.53 Bearing Pad and Bearing Plate Design

13.54 Bearing Pad and Bearing Plate Details

Load Rating

13.55 Load Ratings

13 STRUCTURES MEDIUM SPAN CONCRETE BRIDGE


A-60
STAGE I FPID(S): 999999-1-52-01
[DATE]

14 STRUCTURES - STRUCTURAL STEEL BRIDGE

The CONSULTANT shall prepare plans for Structural Steel Bridge(s) at the location(s)
specified in Section 2.5.

General Layout Design and Plans

14.1 Overall Bridge Final Geometry

14.2 Expansion/Contraction Analysis

14.3 General Plan and Elevation

14.4 Construction Staging

14.5 Approach Slab Plan and Details

14.6 Miscellaneous Details

End Bent Design and Plans

14.7 End Bent Geometry

14.8 Wingwall Design and Geometry

14.9 End Bent Structural Design

14.10 End Bent Plan and Elevation

14.11 End Bent Details

Intermediate Bent Design and Plans

14.12 Bent Geometry

14.13 Bent Stability Analysis

14.14 Bent Structural Design

14.15 Bent Plan and Elevation

14.16 Bent Details

Pier Design and Plans

14.17 Pier Geometry

14.18 Pier Stability Analysis

14 STRUCTURES STRUCTURAL STEEL BRIDGE


A-61
STAGE I FPID(S): 999999-1-52-01
[DATE]

14.19 Pier Structural Design

14.20 Pier Plan and Elevation

14.21 Pier Details

Miscellaneous Substructure Design and Plans

14.22 Foundation Layout

Superstructure Deck Design and Plans

14.23 Finish Grade Elevation (FGE) Calculation

14.24 Finish Grade Elevations

14.25 Bridge Deck Design

14.26 Bridge Deck Reinforcing and Concrete Quantities

14.27 Superstructure Plan

14.28 Superstructure Section

14.29 Miscellaneous Bridge Deck Details

Reinforcing Bar Lists

14.30 Preparation of Reinforcing Bar List

Structural Steel Plate Girder Design

14.31 Unit Modeling

14.32 Section Design

14.33 Stiffener Design and Locations

14.34 Cross-frame Design

14.35 Connections

14.36 Bearing Assembly Design and Detailing (With Jacking Analysis)

14.37 Splice Design

14.38 Shear Stud Connectors

14.39 Deflection Analysis

14.40 Framing Plan

14 STRUCTURES STRUCTURAL STEEL BRIDGE


A-62
STAGE I FPID(S): 999999-1-52-01
[DATE]

14.41 Girder Elevation

14.42 Structural Steel Details

14.43 Splice Details

14.44 Girder Deflections and Camber

Structural Steel Box Girder Design

14.45 Unit Modeling

14.46 Section Design

14.47 Stiffener Design and Locations

14.48 Interior Cross-Frame Design

14.49 Exterior Cross-Frame Design

14.50 Connections

14.51 Bearing Assembly Design and Detailing (with Jacking Analysis)

14.52 Splice Design

14.53 Shear Stud Connectors

14.54 Deflection Analysis

14.55 Framing Plan

14.56 Girder Elevation

14.57 Structural Steel Details

14.58 Splice Details

14.59 Girder Deflections and Camber

Erection Scheme

14.60 Erection Scheme Analysis

14.61 Erection Scheme

Load Rating

14.62 Load Rating

14 STRUCTURES STRUCTURAL STEEL BRIDGE


A-63
STAGE I FPID(S): 999999-1-52-01
[DATE]

15 STRUCTURES - SEGMENTAL CONCRETE BRIDGE

The CONSULATANT shall prepare plans for Segmental Concrete Bridge(s) at the
location(s) specified in Section 2.5.

General Layout Design and Plans

15.1 Final Bridge Geometry

15.2 Casting Geometry Calculation

15.3 Finish Grade Geometry Calculation

15.4 Finish Grade Elevations

15.5 Construction Schedule

15.6 General Plan and Elevation

15.7 Approach Slab Plan and Details

15.8 Miscellaneous Details

15.9 Existing Bridge Plans

End Bent Design and Plans

15.10 End Bent Geometry

15.11 Wingwall Geometry and Design

15.12 End Bent Structural Design

15.13 End Bent Plan and Elevation

15.14 End Bent Details

Pier Design and Plans

15.15 Pier Geometry

15.16 Pier Stability Analysis

15.17 Pier Construction Loads

15.18 Pier Structural Design

15 STRUCTURES SEGMENTAL CONCRETE BRIDGE


A-64
STAGE I FPID(S): 999999-1-52-01
[DATE]

15.19 Pier Plan and Elevation

15.20 Pier Details

Miscellaneous Substructure Design and Plans

15.21 Foundation Layout

Longitudinal Analysis

15.22 Section Properties

15.23 Material Properties

15.24 Superimposed Dead Loads

15.25 Construction Sequence

15.26 Tendon Layouts

15.27 Live Load Analysis

15.28 Temperature Gradient

15.29 Time Dependent Analysis

15.30 Stress Summary

15.31 Ultimate Moments

15.32 Ultimate Shear

15.33 Construction Loading

Transverse Analysis

15.34 Time Dependent Analysis

15.35 Live Load Analysis

15.36 Temperature Gradient

15.37 Stress Summary

15.38 Ultimate Moments

15.39 Construction Loading

15 STRUCTURES SEGMENTAL CONCRETE BRIDGE


A-65
STAGE I FPID(S): 999999-1-52-01
[DATE]

Superstructure Design

15.40 Typical Segment

15.41 Pier Segment

15.42 Expansion Joint Segment

15.43 Blister Details

15.44 Deviator Blocks

15.45 Bearings

15.46 Expansion Joints

15.47 Special Analysis

Superstructure Plans

15.48 Typical Sections

15.49 Finish Grade Elevations

15.50 Segment Layout / Designations

15.51 Typical Segments

15.52 Variable Depth Segments

15.53 Pier Segments

15.54 Expansion Joint Segments

15.55 CIP Closure Joint Details

15.56 Casting Geometry

15.57 Integrated 3-D Drawings

Post-Tensioning Details

15.58 Bulkhead Details

15.59 Transverse Tendon Layout

15.60 Longitudinal Tendon Layout

15.61 Temporary Post-Tensioning

15 STRUCTURES SEGMENTAL CONCRETE BRIDGE


A-66
STAGE I FPID(S): 999999-1-52-01
[DATE]

15.62 Quantities and Stressing Schedule

15.63 Future Post-Tensioning

15.64 Anchorage Blisters

15.65 Deviation Blocks

15.66 PT Grouting Plan Details

Miscellaneous Details

15.67 Erection Sequence and Details

15.68 Access Opening Details

15.69 Bearings

15.70 Expansion Joints

15.71 Vermin Screen Details

15.72 Railing Details

15.73 Lighting and Luminaries

15.74 Architectural Details

15.75 Special Systems

Reinforcing Bar Lists

15.76 Preparation of Reinforcing Bar Lists

Load Rating

15.77 Load Rating (LRFR)

15 STRUCTURES SEGMENTAL CONCRETE BRIDGE


A-67
STAGE I FPID(S): 999999-1-52-01
[DATE]

16 STRUCTURES - MOVABLE SPAN

The CONSULTANT shall prepare plans for Movable Span Bridge(s) at the location(s)
specified in Section 2.5.

Final Design Bascule Pier

16.1 Pier Deck

16.2 Leaf/Pier Clearance Diagrams

16.3 Load Shoe Columns

16.4 Trunnion Columns

16.5 Foundations

16.6 Footing

16.7 Seal

16.8 Back Wall (Approach Span Bearings) Closed Piers only

16.9 Bascule Pier Deck Elevations

Bascule Pier Dimensions - Detailing

16.10 Pier Plan Views

16.11 Pier Elevations Views

16.12 Pier Sections

Bascule Pier Reinforcing Details

16.13 Pier Reinforcing

Bascule Pier Miscellaneous Details

16.14 Pier Barrier Details

16.15 Stair Details

16.16 Handrail Details

16.17 Ladder and Hatch Details

16 STRUCTURES MOVABLE SPAN


A-68
STAGE I FPID(S): 999999-1-52-01
[DATE]

16.18 Pier Equipment

16.19 Bascule Pier Notes and Summary of Quantities

16.20 Miscellaneous Details

Bascule Leaf Design

16.21 Deck Design

16.22 Sidewalk Design

16.23 Stringer Design

16.24 Typical Floorbeam Design

16.25 End Floorbeam Design

16.26 Deep Floorbeam Design

16.27 Sidewalk Bracket Design

16.28 Roadway Bracket Design

16.29 Main Girder Influence Lines

16.30 Main Girder Design

16.31 Trunnion Girder Design

16.32 Main Girder Camber Data

16.33 Leaf Lateral Bracing Design

16.34 Counterweight Design

16.35 Live Load Shoe Design

16.36 Barrier Design

16.37 Deck Elevations

16.38 Balance Calculations

Bascule Leaf Detailing

16.39 Bascule GP&E

16.40 Bascule Leaf Notes

16 STRUCTURES MOVABLE SPAN


A-69
STAGE I FPID(S): 999999-1-52-01
[DATE]

16.41 Framing Plan

16.42 Flooring Plan and Details

16.43 Typical Section and Finish Grade Elevations

16.44 Girder Elevation

16.45 Girder Details

16.46 Camber Layout

16.47 Floor Beams

16.48 Counterweight Girder/Box

16.49 Trunnion Girder

16.50 Cylinder Girder

16.51 Lateral Bracing Details

16.52 Counterweight Bracing Details

16.53 Joint Details

16.54 Traffic Barrier Details

16.55 Pedestrian Rail and Support Details

16.56 Curb and Sidewalk Details

16.57 Barrier and Sidewalk Bracket Details

16.58 Counterweight Details

16.59 Stress Table or Influence Lines

Mechanical Design

16.60 Final Power Requirements

16.61 Trunnion Assembly

16.62 Span Locks

16.63 Sump Pumps

16 STRUCTURES MOVABLE SPAN


A-70
STAGE I FPID(S): 999999-1-52-01
[DATE]

Mechanical Drive Design

16.64 Drive Shafts, Couplings, Keys, Bearings and Supports

16.65 Rack and Pinion, Bearings and Supports

16.66 Drive Train

16.67 Motor Brakes and Machinery Brakes

Hydraulic Drive Design

16.68 Hydraulic Drive

Machinery Detailing

16.69 Machinery Layout

16.70 Machinery Elevation

16.71 Machinery Section

16.72 Trunnion Assembly

16.73 Drive Details

16.74 Span Locks

Electrical Design

16.75 Load Analysis

16.76 Power Distribution

16.77 Drive Equipment

16.78 Bridge Controls

16.79 Grounding

16.80 Lightning and Surge Suppression

16.81 Pier Lighting

Electrical Detailing

16.82 Electrical Plan and Elevation

16.83 Electrical Symbols and Abbreviations

16 STRUCTURES MOVABLE SPAN


A-71
STAGE I FPID(S): 999999-1-52-01
[DATE]

16.84 Single/Three Line Diagram

16.85 Panel Board and Light Fixture Schedules

16.86 Wire and Conduit Schedules and Diagrams

16.87 Control Desk/Panel Layout

16.88 Control Schematics

16.89 PLC Logic

16.90 Communication System

16.91 Navigation Lighting Details

16.92 Pedestrian Gate, Traffic Gate, and Barrier Details

16.93 Submarine Cable

16.94 Miscellaneous Details

Control House

16.95 Architectural Design

16.96 Architectural Details

16.97 Structural Design

16.98 Structural Details

16.99 HVAC/Plumbing Design

16.100 HVAC/Plumbing/Electrical Cables

Reinforcing Bar Lists

16.101 Preparation of Reinforcing Bar List

Load Rating

16.102 Load Rating

16 STRUCTURES MOVABLE SPAN


A-72
STAGE I FPID(S): 999999-1-52-01
[DATE]

17 STRUCTURES - RETAINING WALLS

The CONSULTANT shall prepare plans for Retaining Wall(s) as specified in Section 2.5.

General Requirements

17.1 Key Sheet

17.2 Horizontal Wall Geometry

Permanent Proprietary Walls

17.3 Vertical Wall Geometry

17.4 Semi-Standard Drawings

17.5 Wall Plan and Elevations (Control Drawings)

17.6 Details

Temporary Proprietary Walls

17.7 Vertical Wall Geometry

17.8 Semi-Standard Drawings

17.9 Wall Plan and Elevations (Control Drawings)

17.10 Details

Cast-In-Place Retaining Walls

17.11 Design

17.12 Vertical Wall Geometry

17.13 General Notes

17.14 Wall Plan and Elevations (Control Drawings)

17.15 Sections and Details

17.16 Reinforcing Bar List

Other Retaining Walls and Bulkheads

17.17 Design

17 STRUCTURES RETAINING WALL


A-73
STAGE I FPID(S): 999999-1-52-01
[DATE]

17.18 Vertical Wall Geometry

17.19 General Notes, Tables and Miscellaneous Details

17.20 Wall Plan and Elevations

17.21 Details

17 STRUCTURES RETAINING WALL


A-74
STAGE I FPID(S): 999999-1-52-01
[DATE]

18 STRUCTURES - MISCELLANEOUS

The CONSULTANT shall prepare plans for Miscellaneous Structure(s) as specified in


Section 2.5.

Concrete Box Culverts

18.1 Concrete Box Culverts

18.2 Concrete Box Culverts Extensions

18.3 Concrete Box Culvert Data Table Plan Sheets

18.4 Concrete Box Culvert Special Details Plan Sheets

Strain Poles

18.5 Steel Strain Poles

18.6 Concrete Strain Poles

18.7 Strain Pole Data Table Plan Sheets

18.8 Strain Pole Special Details Plan Sheets

Mast Arms

18.9 Mast Arms

18.10 Mast Arms Data Table Plan Sheets

18.11 Mast Arms Special Details Plan Sheets

Overhead/Cantilever Sign Structure

18.12 Cantilever Sign Structures

18.13 Overhead Span Sign Structures

18.14 Special (Long Span) Overhead Sign Structures

18.15 Monotube Overhead Sign Structure

18.16 Bridge Mounted Signs (Attached to Superstructure)

18.17 Overhead/Cantilever Sign Structures Data Table Plan Sheets

18 STRUCTURES MISCELLANEOUS
A-75
STAGE I FPID(S): 999999-1-52-01
[DATE]

18.18 Overhead/Cantilever Sign Structures Special Details Plan Sheets

High Mast Lighting

18.19 Non-Standard High Mast Lighting Structures

18.20 High Mast Lighting Special Details Plan Sheets

Noise Barrier Walls (Ground Mount)

18.21 Horizontal Wall Geometry

18.22 Vertical Wall Geometry

18.23 Summary of Quantities Aesthetic Requirements

18.24 Control Drawings

18.25 Design of Noise Barrier Walls Covered by Standards

18.26 Design of Noise Barrier Walls not Covered by Standards

18.27 Aesthetic Details

Special Structures

18.28 Fender System

18.29 Fender System Access

18.30 Special Structures

18.31 Other Structures

18 STRUCTURES MISCELLANEOUS
A-76
STAGE I FPID(S): 999999-1-52-01
[DATE]

19 SIGNING AND PAVEMENT MARKING ANALYSIS

The CONSULTANT shall analyze and document Signing and Pavement Markings Tasks in
accordance with all applicable manuals, guidelines, standards, handbooks, procedures, and
current design memorandums.

19.1 Traffic Data Analysis

The CONSULTANT shall review the approved preliminary engineering report, typical
section package, traffic technical memorandum and proposed geometric design alignment to
identify proposed sign placements and roadway markings. Perform queue analysis.

19.2 No Passing Zone Study

The CONSULTANT shall perform all effort required for field data collection, and
investigation in accordance with the DEPARTMENTs Manual on Uniform Traffic Studies.

The CONSULTANT shall submit the signed and sealed report to the DEPARTMENT for
review and approval.

19.3 Reference and Master Design File

The CONSULTANT shall prepare the Signing & Marking Design file to include all
necessary design elements and all associated reference files.

19.4 Multi-Post Sign Support Calculations

The CONSULTANT shall determine the appropriate column size from the DEPARTMENTs
Multi-Post Sign Program(s).

19.5 Sign Panel Design Analysis

Establish sign layout, letter size and series for non-standard signs.

19.6 Sign Lighting/Electrical Calculations

The CONSULTANT shall analyze and document Lighting/Electrical Tasks in accordance


with all applicable manuals, guidelines, standards, handbooks, procedures, and current
design memorandums.

The CONSULTANT shall prepare a photometric analysis to be submitted as part of the


Lighting Design Analysis Report. An analysis shall be provided for each new and/or
modified sign panel which requires lighting.

The Consultant shall submit voltage drop calculations and load analysis for each new and/or
modified sign panel which requires lighting.

19.7 Quantities

19 SIGNING AND PAVEMENT MARKING ANALYSIS


A-77
STAGE I FPID(S): 999999-1-52-01
[DATE]

19.8 Cost Estimate

19.9 Technical Special Provisions

19.10 Other Signing and Pavement Marking Analysis

19.11 Field Reviews

19.12 Technical Meetings

19.13 Quality Assurance/Quality Control

19.14 Independent Peer Review

19.15 Supervision

19.16 Coordination

19 SIGNING AND PAVEMENT MARKING ANALYSIS


A-78
STAGE I FPID(S): 999999-1-52-01
[DATE]

20 SIGNING AND PAVEMENT MARKING PLANS

The CONSULTANT shall prepare a set of Signing and Pavement Marking Plans in
accordance with all applicable manuals, guidelines, standards, handbooks, procedures, and
current design memorandums that includes the following.

20.1 Key Sheet

20.2 Summary of Pay Items Including Quantity Input

20.3 Tabulation of Quantities

20.4 General Notes/Pay Item Notes

20.5 Project Layout

20.6 Plan Sheet

20.7 Typical Details

20.8 Guide Sign Work Sheet(s)

20.9 Traffic Monitoring Site

20.10 Cross Sections

20.11 Special Service Point Details

20.12 Special Details

20.13 Interim Standards

20.14 Quality Assurance/Quality Control

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of traffic design drawings, specifications and other services furnished by the
CONSULTANT under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all design drawings, specifications and
other services prepared as a part of the contract. The CONSULTANT shall describe how the
checking and review processes are to be documented to verify that the required procedures
were followed. The Quality Control Plan may be one utilized by the CONSULTANT as part
of their normal operation or it may be one specifically designed for this project.

20.15 Supervision

20 SIGNING AND PAVEMENT MARKING PLANS


A-79
STAGE I FPID(S): 999999-1-52-01
[DATE]

21 SIGNALIZATION ANALYSIS

The CONSULTANT shall analyze and document Signalization Analysis Tasks in accordance
with all applicable manuals, guidelines, standards, handbooks, procedures, and current
design memorandums.

21.1 Traffic Data Collection

The CONSULTANT shall perform all effort required for traffic data collection, including
crash reports, 24 hr. machine counts, 8 hr. turning movement counts, 7 day machine counts,
and speed & delay studies.

21.2 Traffic Data Analysis

The CONSULTANT shall determine signal operation plan, intersection geometry, local
signal timings, pre-emption phasing & timings, forecasting traffic, and intersection analysis
run.

21.3 Signal Warrant Study

21.4 Systems Timings

The CONSULTANT shall determine proper coordination timing plans including splits, force
offs, offsets, and preparation of Time Space Diagram.

21.5 Reference and Master Signalization Design File

The CONSULTANT shall prepare the Signalization Design file to include all necessary
design elements and all associated reference files.

21.6 Reference and Master Interconnect Communication Design File

The CONSULTANT shall prepare the Interconnect Communication Design file to include all
necessary design elements and all associated reference files.

21.7 Overhead Street Name Sign Design

The CONSULTANT shall design Signal Mounted Overhead Street Name signs.

21.8 Pole Elevation Analysis

21.9 Traffic Signal Operation Report

[As defined by the District]

21.10 Quantities

21.11 Cost Estimate

21 SIGNALIZATION ANALYSIS
A-80
STAGE I FPID(S): 999999-1-52-01
[DATE]

21.12 Technical Special Provisions

21.13 Other Signalization Analysis

21.14 Field Reviews

The CONSULTANT shall collect information from the maintaining agencies and conduct a
field review. The review should include, but is not limited to, the following:

Existing Signal and Pedestrian Phasing


Controller Make, Model, Capabilities and Condition/Age
Condition of Signal Structure(s)
Type of Detection as Compared With Current District Standards
Interconnect Media
Controller Timing Data
21.15 Technical Meetings

21.16 Quality Assurance/Quality Control

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of traffic design drawings, specifications and other services furnished by the
CONSULTANT under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all design drawings, specifications and
other services prepared as a part of the contract. The CONSULTANT shall describe how the
checking and review processes are to be documented to verify that the required procedures
were followed. The Quality Control Plan may be one utilized by the CONSULTANT as part
of their normal operation or it may be one specifically designed for this project.

21.17 Independent Peer Review

21.18 Supervision

21.19 Coordination

21 SIGNALIZATION ANALYSIS
A-81
STAGE I FPID(S): 999999-1-52-01
[DATE]

22 SIGNALIZATION PLANS

The CONSULTANT shall prepare a set of Signalization Plans in accordance with all
applicable manuals, guidelines, standards, handbooks, procedures, and current design
memorandums, which includes the following:

22.1 Key Sheet

22.2 Summary of Pay Items Including Designer Interface Quantity Input

22.3 Tabulation of Quantities

22.4 General Notes/Pay Item Notes

22.5 Plan Sheet

22.6 Interconnect Plans

22.7 Traffic Monitoring Site

22.8 Guide Sign Worksheet

22.9 Special Details

22.10 Special Service Point Details

22.11 Mast Arm/Monotube Tabulation Sheet

22.12 Strain Pole Schedule

22.13 TCP Signal (Temporary)

22.14 Temporary Detection Sheet

22.15 Utility Conflict Sheet

22.16 Interim Standards

22.17 Quality Assurance/Quality Control

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of traffic design drawings, specifications and other services furnished by the
CONSULTANT under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all design drawings, specifications and
other services prepared as a part of the contract. The CONSULTANT shall describe how the
checking and review processes are to be documented to verify that the required procedures

22 SIGNALIZATION PLANS
A-82
STAGE I FPID(S): 999999-1-52-01
[DATE]

were followed. The Quality Control Plan may be one utilized by the CONSULTANT as part
of their normal operation or it may be one specifically designed for this project.

22.18 Supervision

22 SIGNALIZATION PLANS
A-83
STAGE I FPID(S): 999999-1-52-01
[DATE]

23 LIGHTING ANALYSIS

The CONSULTANT shall analyze and document Lighting Tasks in accordance with all
applicable manuals, guidelines, standards, handbooks, procedures, and current design
memorandums.

23.1 Lighting Justification Report

The CONSULTANT shall prepare a Lighting Justification Report. The report shall be
submitted under a separate cover with the Phase I plans submittal, titled Lighting
Justification Report. The report shall provide analyses for mainlines, interchanges, and
arterial roads and shall include all back-up data such that the report stands on its own. Back
up data shall include current ADTs, general crash data average cost from the Florida
Highway Safety Improvement Manual, crash details data from the last three years, and
preliminary lighting calculations.

The report shall address warrants to determine if lighting warrants are met, and shall include
a benefit-cost analysis to determine if lighting is justified. The report shall include
calculations for the night-to-day crash ratio as well as a table summarizing the day-time and
the night-time crashes. The report shall follow the procedures outlined in the FDOT Manual
on Uniform Traffic Studies (MUTS) manual which utilize ADT, Three Year Crash Data,
night/day crash ratio, percentage of night ADT, etc.

23.2 Lighting Design Analysis Report

The CONSULTANT shall prepare a Preliminary Lighting Design Analysis Report. The
report shall be submitted under a separate cover with the Phase II plans submittal. The report
shall provide analyses for each typical section of the mainline, typical section for the ramps
(one and/or two lanes), interchanges, underdeck lighting, and arterial roads. Each lighting
calculation shall be properly identified as to the area that it covers.

The report shall include the Lighting Design Criteria that will be used and shall include the
evaluation of at least three lighting design alternatives and a recommendation on the
alternative to use. Each alternative shall be properly described; the alternatives shall consider
different pole heights, lamp wattage, and arm lengths. Each alternative shall be provided
with a cost estimate that includes initial cost in addition to operations and maintenance cost
for one year.

The report shall also include the lighting calculations for each lighted sign.

After approval of the preliminary report, the CONSULTANT shall submit a revised report
for each submittal. The Lighting Design Analysis Report shall include:

Voltage drop calculations

Load analysis calculations for each branch circuit

23.3 Aeronautical Evaluation

The CONSULTANT shall prepare an Aeronautical Evaluation/Airspace Analysis Report for

23 LIGHTING ANALYSIS
A-84
STAGE I FPID(S): 999999-1-52-01
[DATE]

those projects within [XX] miles of an airport. It shall be submitted for approval by the
DEPARTMENT and by FAA prior to Phase II plans submittal.

The report shall include an evaluation of the glide slope of all adjacent airport runways
(including future runways) and the preparation of the required FAA forms and special
lighting calculations based on NO PENETRATION of the approach or transitional surfaces
and coordination with the Airport Manager.

The report shall include a profile drawing for each condition affected by the runway
approach and transitional surfaces. This drawing(s) shall show the roadway profile grade
line at the edge of the shoulder pavement with proper baseline stations, the FAR Part 77 -
50:1 (or 34:1) approach surface line and the 7:1 transitional surface line. The scale of this
drawing shall be 1=100 horizontal and 1=10 vertical. The proposed location of each light
pole shall be properly shown at the respective station to clearly indicate that no penetration
to either the approach surface or to the transitional surface is anticipated.

23.4 Voltage Drop Calculations

The CONSULTANT shall submit voltage drop calculations showing the equation or
equations used along with the number of luminaries per circuit, the length of each circuit,
the size conductor or conductors used and their ohm resistance values. The voltage drop
incurred on each circuit (total volts and percentage of drop) shall be calculated, and all work
necessary to calculate the voltage drop values for each circuit should be presented in such a
manner as to be duplicated by the District.

The Voltage Drop Calculations shall be submitted as part of the Lighting Design Analysis
Report.

23.5 FDEP Coordination and Report

23.6 Reference and Master Design Files

The CONSULTANT shall prepare the Lighting Design file to include all necessary design
elements and all associated reference files.

23.7 Temporary Lighting

The CONSULTANT shall provide temporary lighting requirements for all affected phases of
construction to light roadways in areas where required. The temporary lighting shall be
included with the Traffic Control Plans with proper notes, illumination and uniformity
criteria and details.

23.8 Design Documentation

The CONSULTANT shall submit a Design Documentation with each plans submittal under
a separate cover and not part of the roadway documentation book. At a minimum, the design
documentation shall include:

Phase submittal checklist.


Structural calculations for special conventional pole concrete foundations.
Correspondence with the power company concerning new electrical service.

23 LIGHTING ANALYSIS
A-85
STAGE I FPID(S): 999999-1-52-01
[DATE]

23.9 Quantities

23.10 Cost Estimate

23.11 Technical Special Provisions

23.12 Other Lighting Analysis

23.13 Field Reviews

The CONSULTANT shall collect information from the maintaining agencies and conduct a
field review. The review should include but is not limited to the following:

Existing Lighting Equipment


Load Center, Capabilities and Condition/Age
Condition of Lighting Structure(s)
Verification of horizontal clearances
Verification of breakaway requirements
23.14 Technical Meetings

23.15 Quality Assurance/Quality Control

23.16 Independent Peer Review

23.17 Supervision

23.18 Coordination

23 LIGHTING ANALYSIS
A-86
STAGE I FPID(S): 999999-1-52-01
[DATE]

24 LIGHTING PLANS

The CONSULTANT shall prepare a set of Lighting Plans in accordance with all applicable
manuals, guidelines, standards, handbooks, procedures, and current design memorandums.

24.1 Key Sheet

24.2 Summary of Pay Item Sheet Including Designer Interface Quantity Input

24.3 Tabulation of Quantities

24.4 General Notes/Pay Item Notes

24.5 Pole Data, Legend & Criteria

24.6 Service Point Details

24.7 Project Layout

24.8 Plan Sheet

24.9 Special Details

24.10 Temporary Lighting Data and Details

24.11 Traffic Control Plan Sheets

24.12 Interim Standards

24.13 Quality Assurance/Quality Control

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of traffic design drawings, specifications and other services furnished by the
CONSULTANT under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all design drawings, specifications and
other services prepared as a part of the contract. The CONSULTANT shall describe how the
checking and review processes are to be documented to verify that the required procedures
were followed. The Quality Control Plan may be one utilized by the CONSULTANT as part
of their normal operation or it may be one specifically designed for this project.

24.14 Supervision

24 LIGHTING PLANS
A-87
STAGE I FPID(S): 999999-1-52-01
[DATE]

25 LANDSCAPE ARCHITECTURE ANALYSIS

The CONSULTANT shall analyze and document Landscape Architecture Tasks in


accordance with all applicable manuals, guidelines, standards, handbooks, procedures, and
current design memorandums.

25.1 Data Collection

All research required to collect data necessary to complete the initial design analysis.
Includes identifying local ordinances and collection of other project data.

25.2 Site Inventory and Analysis for Proposed Landscape

Includes identification of opportunities and constraints for the proposed landscape project
based on existing site conditions. Identify available planting areas for nursery landscape
material. Summary of analysis, if required, is included in conceptual design.

25.3 Planting Design

Conceptual Design: Includes delineation of all proposed planting types, scheme


development and preliminary costs and reports. The design shall be submitted with the
Phase I plans.

Final Design: Includes identifying the species/type, size, location, spacing, and quality of all
plants.

25.4 Irrigation Design

Feasibility Report: Includes analysis of methods, materials and operation costs associated
with proposed irrigation system design.

Conceptual Design: Typically not done in master design file. Includes determination of
water and power sources. Phase I design level.

Final Design: Includes all work in master design files. Irrigation Design includes, but is not
limited to, the locations and sizes of pumps, pump stations, mainlines, lateral lines, irrigation
heads, valves, backflow and control devices.

25.5 Hardscape Design

Conceptual design - scheme development and preliminary costs: Typically not done in
master design file. Delineation of areas and elements to be included in design. Select cut
sheets, prepare image boards. Includes report, if required.

Final Design: Includes all work in master design files. Hardscape Design includes, but is not
limited to, sidewalks, plazas, Steps, Fountains, Walls, Pedestrian bridges, non-regulatory
signs or project graphics, roadway aesthetics, site furnishings.

25.6 Plan Summary Boxes

25 LANDSCAPE ARCHITECTURE ANALYSIS


A-88
STAGE I FPID(S): 999999-1-52-01
[DATE]

25.7 Cost Estimates

25.8 Technical Special Provisions

25.9 Other Landscape Architecture

25.10 Outdoor Advertising

Includes all work required to determine locations of all outdoor advertising permitted within
the roadway project limits. Includes all work required to determine the proposed view zones
and the supporting documentation.

25.11 Field Reviews

25.12 Technical Meetings / Public Meetings

25.13 Quality Assurance/Quality Control

25.14 Independent Peer Review

25.15 Supervision

25.16 Project Coordination

25.17 Interdisciplinary Coordination

25 LANDSCAPE ARCHITECTURE ANALYSIS


A-89
STAGE I FPID(S): 999999-1-52-01
[DATE]

26 LANDSCAPE ARCHITECTURE PLANS

The CONSULTANT shall prepare a set of Landscape Plans which includes the following.

26.1 Key Sheet

26.2 Tabulation of Quantities

26.3 General Notes

26.4 Tree and Vegetation Inventory, Protection and Relocation Plans

26.5 Planting Plans for Linear Roadway Projects

26.6 Planting Plans (Interchanges and Toll Plazas)

26.7 Planting Details and Notes

26.8 Irrigation Plans for Linear Roadway Project

26.9 Irrigation Plans for Interchange and Toll Plazas

26.10 Irrigation Details and Notes

26.11 Hardscape Plans

26.12 Hardscape Details and Notes

26.13 Landscape Maintenance Plan

The CONSULTANT shall include a written plan for care and maintenance of the plants and
beds, hardscape, and irrigation system after the warranty period. The landscape maintenance
plan will be developed in performance based language and will be in coordination with the
local government entity who assumes the maintenance obligation.

26.14 Cost Estimate

26.15 Quality Assurance/Quality Control

26.16 Supervision

26 LANDSCAPE ARCHITECTURE PLANS


A-90
STAGE I FPID(S): 999999-1-52-01
[DATE]

27 SURVEY

The CONSULTANT shall perform survey tasks in accordance with all applicable statutes,
manuals, guidelines, standards, handbooks, procedures, and current design memoranda.

The CONSULTANT shall submit all survey notes and computations to document the
surveys. All field survey work shall be recorded in approved media and submitted to the
DEPARTMENT. Field books submitted to the DEPARTMENT must be of an approved type.
The field books shall be certified by the surveyor in responsible charge of work being
performed before the final product is submitted.

The survey notes shall include documentation of decisions reached from meetings,
telephone conversations or site visits. All like work (such as bench lines, reference points,
etc.) shall be recorded contiguously. The DEPARTMENT may not accept field survey radial
locations of section corners, platted subdivision lot and block corners, alignment control
points, alignment control reference points and certified section corner references. The
DEPARTMENT may instead require that these points be surveyed by true line, traverse or
parallel offset.

27.1 Horizontal Project Control (HPC)

Establish or recover HPC, for the purpose of establishing horizontal control on the Florida
State Plane Coordinate System or datum approved by the District Surveyor (DS) or District
Location Surveyor (DLS); may include primary or secondary control points. Includes
analysis and processing of all field collected data, and preparation of forms.

27.2 Vertical Project Control (VPC)

Establish or recover VPC, for the purpose of establishing vertical control on datum approved
by the District Surveyor (DS) or the District Location Surveyor (DLS).; may include
primary or secondary vertical control points. Includes analysis and processing of all field
collected data, and preparation of forms.

27.3 Alignment and/or Existing Right of Way (R/W) Lines

Establish, recover or re-establish project alignment. Also includes analysis and processing of
all field collected data, existing maps, and/or reports for identifying mainline, ramp, offset,
or secondary alignments. Depict alignment and/or existing R/W lines (in required format)
per DEPARTMENT R/W Maps, platted or dedicated rights of way.

27.4 Aerial Targets

Place, locate, and maintain required aerial targets and/or photo identifiable points. Includes
analysis and processing of all field collected data, existing maps, and/or reports. Placement
of the targets will be at the discretion of the aerial firm.

27.5 Reference Points

27 SURVEY
A-91
STAGE I FPID(S): 999999-1-52-01
[DATE]

Reference Horizontal Project Network Control (HPNC) points, project alignment, vertical
control points, section, section, center of section corners and General Land Office
(G.L.O.) corners as required.

27.6 Topography/Digital Terrain Model (DTM) (3D)

Locate all above ground features and improvements for the limits of the project by collecting
the required data for the purpose of creating a DTM with sufficient density. Shoot all break
lines, high and low points. Effort includes field edits, analysis and processing of all field
collected data, existing maps, and/or reports.

27.7 Planimetric (2D)

Locate all above ground features and improvements. Deliver in appropriate electronic
format. Effort includes field edits, analysis and processing of all field collected data, existing
maps, and/or reports.

27.8 Roadway Cross Sections/Profiles

Perform cross sections or profiles. May include analysis and processing of all field-collected
data for comparison with DTM.

27.9 Side Street Surveys

Refer to tasks of this document as applicable.

27.10 Underground Utilities

Designation includes 2-dimensional collection of existing utilities and selected 3-


dimensional verification as needed for designation. Location includes non-destructive
excavation to determine size, type and location of existing utility, as necessary for final 3-
dimensional verification. Survey includes collection of data on points as needed for
designates and locates. Includes analysis and processing of all field collected data, and
delivery of all appropriate electronic files.

27.11 Outfall Survey

Locate all above ground features and improvements for the limits of the project by collecting
the required data for the purpose of a DTM. Survey with sufficient density of shots. Shoot
all break lines, high and low points. Includes field edits, analysis and processing of all field
collected data, existing maps, and/or reports.

27.12 Drainage Survey

Locate underground data (XYZ, pipe size, type, condition and flow line) that relates to
above ground data. Includes field edits, analysis and processing of all field collected data,
existing maps, and/or reports.

27.13 Bridge Survey (Minor/Major)

Locate required above ground features and improvements for the limits of the bridge.
Includes field edits, analysis and processing of all field collected data, existing maps, and/or

27 SURVEY
A-92
STAGE I FPID(S): 999999-1-52-01
[DATE]

reports.

27.14 Channel Survey

Locate all topographic features and improvements for the limits of the project by collecting
the required data. Includes field edits, analysis and processing of all field collected data,
maps, and/or reports.

27.15 Pond Site Survey

Refer to tasks of this document as applicable.

27.16 Mitigation Survey

Refer to tasks of this document as applicable.

27.17 Jurisdiction Line Survey

Perform field location (2-dimensional) of jurisdiction limits as defined by respective


authorities, also includes field edits, analysis and processing of all field collected data,
preparation of reports.

27.18 Geotechnical Support

Perform 3-dimensional (X,Y,Z) field location, or stakeout, of boring sites established by


geotechnical engineer. Includes field edits, analysis and processing of all field collected data
and/or reports.

27.19 Sectional/Grant Survey

Perform field location/placement of section corners, 1/4 section corners, and fractional
corners where pertinent. Includes analysis and processing of all field-collected data and/or
reports.

27.20 Subdivision Location

Survey all existing recorded subdivision/condominium boundaries, tracts, units, phases,


blocks, street R/W lines, common areas. Includes analysis and processing of all field
collected data and/or reports. If unrecorded subdivision is on file in the public records of the
subject county, tie existing monumentation of the beginning and end of unrecorded
subdivision.

27.21 Maintained R/W

Perform field location (2-dimensional) of maintained R/W limits as defined by respective


authorities, if needed. Also includes field edits, analysis and processing of all field collected
data, preparation of reports.

27.22 Boundary Survey

Perform boundary survey as defined by DEPARTMENT standards. Includes analysis and


processing of all field-collected data, preparation of reports.
27 SURVEY
A-93
STAGE I FPID(S): 999999-1-52-01
[DATE]

27.23 Water Boundary Survey

Perform Mean High Water, Ordinary High Water and Safe Upland Line surveys as required
by DEPARTMENT standards.

27.24 Right of Way Staking, Parcel / Right of Way Line

Perform field staking and calculations of existing/proposed R/W lines for on-site review
purposes.

27.25 Right of Way Monumentation

Set R/W monumentation as depicted on final R/W maps for corridor and water retention
areas.

27.26 Line Cutting

Perform all efforts required to clear vegetation from the line of sight.

27.27 Work Zone Safety

Provide work zone as required by DEPARTMENT standards.

27.28 Miscellaneous Surveys

Refer to tasks of this document, as applicable, to perform surveys not described herein. The
percent for Supplemental will be determined at negotiations. This item can only be used if
authorized in writing by the District Surveyor (DS), District Location Surveyor (DLS) or
their representative.

27.29 Supplemental Surveys

Supplemental survey days and hours are to be approved in advance by DS or DLS. Refer to
tasks of this document, as applicable, to perform surveys not described herein.

27.30 Document Research

Perform research of documentation to support field and office efforts involving surveying
and mapping.

27.31 Field Review

Perform verification of the field conditions as related to the collected survey data.

27.32 Technical Meetings

Attend meetings as required and negotiated by the Surveying and Mapping Department.

27.33 Quality Assurance/Quality Control (QA/QC)

Establish and implement a QA/QC plan. Also includes subconsultant review, response to

27 SURVEY
A-94
STAGE I FPID(S): 999999-1-52-01
[DATE]

comments and any resolution meetings if required, preparation of submittals for review, etc.

27.34 Supervision

Perform all activities required to supervise and coordinate project. These activities must be
performed by the project supervisor, a Florida P.S.M. or their delegate as approved by the
District Surveying Office.

27.35 Coordination

Coordinate survey activities with other disciplines. These activities must be performed by
the project supervisor, a Florida P.S.M. or their delegate as approved by the District
Surveying Office.

27 SURVEY
A-95
STAGE I FPID(S): 999999-1-52-01
[DATE]

28 PHOTOGRAMMETRY

The CONSULTANT shall perform photogrammetric tasks in accordance with all applicable
statues, manuals, guidelines, standards, handbooks, procedures, and current design
memoranda.

In addition to the maps and photographic products, the CONSULTANT shall submit all
computations to document the mapping. This will include documentation of all decisions
reached from meetings, telephone conversations, and site visits.

28.1 Flight Preparation

Review record data, create target diagrams, and plan the mission.

28.2 Control Point Coordination

Determine photo identifiable control points, and mark contact prints.

28.3 Mobilization

Perform pre- and post flight aircraft inspection; prepare the aircraft and camera for the
mission.

28.4 Flight Operations

Operate the aircraft, aerial camera, and other instruments to obtain aerial photography.

28.5 Film Processing

Process, check, and annotate the aerial film.

28.6 Photo Products

Prepare contact prints, contact diapositives, and photo enlargements.

28.7 Scanning

Scan photographic images.

28.8 LiDAR

Includes data acquisition, post processing of LiDAR data to XYZ coordinates for "bare
earth" classification.

28.9 Aerial Triangulation

Measure and adjust control within aerial images.

28.10 Surfaces
28 PHOTOGRAMMETRY
A-96
STAGE I FPID(S): 999999-1-52-01
[DATE]

Includes collection of break lines and spot elevations.

28.11 Ortho Generation

Includes creation of final images.

28.12 Rectified Digital Imagery (Georeferenced)

Create the rectified digital image.

28.13 Mosaicking

Create the mosaic.

28.14 Sheet Clipping

Create plot files for sheets from the database.

28.15 Topographics (3D)

Prepare topographic maps including surface and planimetrics. (Photogrammetrist will not
propose hours for Surfaces and Topographics.)

28.16 Planimetrics (2D)

Prepare 2D planimetric map.

28.17 Drainage Basin

Includes preparing drainage basin maps in clipped "sheet" format.

28.18 CADD Edit

Perform final edit of graphics for delivery of required Microstation .dgn, CADD, and
Geopak files.

28.19 Data Merging

Merge photogrammetric files, field survey files, and data from other sources.

28.20 Miscellaneous

Other tasks not specifically addressed in this document.

28.21 Field Review

Perform on site review of maps.

28.22 Technical Meetings

Attend meetings as required.

28 PHOTOGRAMMETRY
A-97
STAGE I FPID(S): 999999-1-52-01
[DATE]

28.23 Quality Assurance/Quality Control

Establish and implement a QA/QC plan.

28.24 Supervision

Supervise all photogrammetric activities. This task must be performed by the project
supervisor, a Florida P.S.M.

28.25 Coordination

Coordinate with all elements of the project to produce a final photogrammetric product.

28 PHOTOGRAMMETRY
A-98
STAGE I FPID(S): 999999-1-52-01
[DATE]

29 MAPPING

The CONSULTANT will be responsible for the preparation of control survey maps, right of
way maps, maintenance maps, sketches, other miscellaneous survey maps, and legal
descriptions as required for this project in accordance with all applicable DEPARTMENT
Manuals, Procedures, Handbooks, District specific requirements, and Florida Statutes. All
maps, surveys and legal descriptions will be prepared under the direction of a Florida
Professional Surveyor and Mapper (PSM) to DEPARTMENT size and format requirements
utilizing DEPARTMENT approved software, and will be designed to provide a high degree
of uniformity and maximum readability. The CONSULTANT will submit maps, legal
descriptions, quality assurance check prints, checklists, electronic media files and any other
documents as required for this project to the DEPARTMENT for review at stages of
completion as negotiated.

Master CADD File

29.1 Alignment

29.2 Section and 1/4 Section Lines

29.3 Subdivisions / Property Lines

29.4 Existing Right of Way

29.5 Topography

29.6 Parent Tract Properties and Existing Easements

29.7 Proposed Right of Way Requirements

The ENGINEER OF RECORD (EOR) will provide the proposed requirements. The PSM is
responsible for calculating the final geometry. Notification of Final Right of Way
Requirements along with the purpose and duration of all easements will be specified in
writing.

29.8 Limits of Construction

The limits of construction DGN file as provided by the EOR will be imported or referenced
to the master CADD file. Additional labeling will be added as required. The PSM is required
to advise the EOR of any noted discrepancies between the limits of construction line and the
existing/proposed right of way lines, and for making adjustments as needed when a
resolution is determined.

29.9 Jurisdictional/Agency Lines

These lines may include, but are not limited to, jurisdictional, wetland, water boundaries,
and city/county limit lines.

29 MAPPING
A-99
STAGE I FPID(S): 999999-1-52-01
[DATE]

Sheet Files

29.10 Control Survey Cover Sheet

29.11 Control Survey Key Sheet

29.12 Control Survey Detail Sheet

29.13 Right of Way Map Cover Sheet

29.14 Right of Way Map Key Sheet

29.15 Right of Way Map Detail Sheet

29.16 Maintenance Map Cover Sheet

29.17 Maintenance Map Key Sheet

29.18 Maintenance Map Detail Sheet

29.19 Reference Point Sheet

This sheet(s) will be included with the Control Survey Map, Right of Way Map and
Maintenance Map.

29.20 Project Network Control Sheet

This sheet depicts the baseline, the benchmarks, the primary and secondary control points
and their reference points including the type of material used for each point, their XYZ
coordinates, scale factors and convergence angles. This sheet(s) may be included with the
Control Survey Map, Right of Way Map and Maintenance Map.

29.21 Table of Ownerships Sheet

Miscellaneous Surveys and Sketches

29.22 Parcel Sketches

29.23 TIITF Sketches

29.24 Other Specific Purpose Survey(s)

29.25 Boundary Survey(s) Map

29.26 Right of Way Monumentation Map

29.27 Title Search Map

29.28 Title Search Report

29 MAPPING
A-100
STAGE I FPID(S): 999999-1-52-01
[DATE]

29.29 Legal Descriptions

29.30 Final Map/Plans Comparison

The PSM will perform a comparison of the final right of way maps with the available
construction plans to review the correctness of the type of parcel to be acquired and the
stations/offsets to the required right of way. The PSM will coordinate with the EOR to
resolve any conflicts or discrepancies and provide documentation of the review.

29.31 Field Reviews

29.32 Technical Meetings

29.33 Quality Assurance/Quality Control

29.34 Supervision

29.35 Coordination

29.36 Supplemental Mapping

This task is to cover efforts resulting from major design and/or development changes after
60% map development that affect the right of way requirements/parent tract property lines
and may include any number of tasks. Request and approval to utilize the Supplemental
Mapping hours will be in writing and approved by the District Right of Way Surveyor prior
to any work being done under this task.

29 MAPPING
A-101
STAGE I FPID(S): 999999-1-52-01
[DATE]

30 TERRESTRIAL MOBILE LiDAR

The CONSULTANT shall perform Terrestrial Mobile LiDAR tasks in accordance with all
applicable statutes, manuals, guidelines, standards, handbooks, procedures, and current
design memoranda.

In addition to the maps and LiDAR products, the CONSULTANT shall submit all
computations and reports to support the mapping. This will include documentation of all
decisions reached from meetings, telephone conversations, and site visits.

30.1 Terrestrial Mobile LiDAR Mission Planning

Research and prepare materials necessary for the successful execution of the Mobile LiDAR
Mission. This includes but is not limited to route and safety planning, GPS /data acquisition
scheduling, weather reports, and site terrain research.

30.2 Project Control Point Coordination

All efforts necessary to coordinate the proper placement of project ground control i.e. base
stations, transformation control points, and validation points, supporting the Mobile LiDAR
survey.

30.3 Terrestrial Mobile LiDAR Mobilization

Prepare the LiDAR sensor and vehicle for project data collection, and get specialized
personnel and equipment on site.

30.4 Terrestrial Mobile LiDAR Mission

Perform site calibrations of LiDAR sensor and collect laser survey data, including any
simultaneous base station GPS occupations and operation of any necessary safety
equipment.

30.5 Terrestrial Mobile LiDAR Processing

Download and post process collected measurement data from Mobile LiDAR vehicle
sensors, and any base stations occupied during mission. Analyze Mobile LiDAR
measurement points and scan route overlaps. Separate any large point cloud data sets into
manageable file sizes with corresponding indexes.

30.6 Terrestrial Mobile Photography Processing

Process, reference, and name digital photographic imagery files collected during Mobile
LiDAR mission.

30.7 Transformation / Adjustment

Adjust LiDAR point cloud data to Project Control points. Create point cloud data file(s) in
approved digital format. Prepare required reports of precision and accuracy achieved. If this

30 TERRESTRIAL MOBILE LiDAR


A-102
STAGE I FPID(S): 999999-1-52-01
[DATE]

task is performed by separate firm, or is the final product to be delivered, include effort for
Survey Report.

30.8 Classification / Editing

Indentify and attribute (classify) point cloud data into requested groups. Classify or remove
erroneous points.

30.9 Specific Surface Reporting

Prepare reports, data and/or graphics of specific surface details such as, but not limited to
pavement rutting, bridge structure clearance to roadway surface.

30.10 Topographic (3D) Mapping

Produce three dimensional (3D) topographic survey map(s) from collected Mobile LiDAR
data. This includes final preparation of Construction Information Management (CIM)
deliverable, if applicable.

30.11 Topographic (2D) Planimetric Mapping

Produce two dimensional (2D) planimetric map(s) from collected Mobile LiDAR data.

30.12 CADD Edits

Perform final edit of graphics for delivery of required CADD files. This includes final
presentation of CIM deliverable, if applicable.

30.13 Data Merging

Merge Mobile LiDAR survey and mapping files, with other field survey files, and data from
other sources.

30.14 Miscellaneous

Other tasks not specifically addressed in this document.

30.15 Field Reviews

Perform on site review of maps.

30.16 Technical Meetings

Attend meetings as required.

30.17 Quality Assurance/ Quality Control

Establish and implement a QA/QC plan.

30.18 Supervision

30 TERRESTRIAL MOBILE LiDAR


A-103
STAGE I FPID(S): 999999-1-52-01
[DATE]

Supervise all Terrestrial Mobile LiDAR activities. This task must be performed by the
project supervisor, a Florida P.S.M.

30.19 Coordination

Coordinate with all elements of the project to produce a final product.

30 TERRESTRIAL MOBILE LiDAR


A-104
STAGE I FPID(S): 999999-1-52-01
[DATE]

31 ARCHITECTURE DEVELOPMENT

PHASE I - 30% DESIGN DEVELOPMENT

After receipt of written authorization to proceed from the DEPARTMENT and based on the
approvals and any authorized adjustments to the Project Scope, Project Schedule or Budget,
the Design Professional shall prepare, submit and present for approval by the
DEPARTMENT, Phase I (30%) documents, comprised of, but not limited, to the following:

Documents

Architectural and Civil site plan(s) showing, in addition to site survey requirements,
landscaping, drainage, water retention ponds, sewage disposal and water-supply system,
chilled water supply and return piping and such physical features that may adversely
affect or enhance the safety, health, welfare, visual environment, or comfort of the
occupants.
A statement on the site plan signed and dated by the Design Professional or his
designated subconsultant, including identifying the number of existing trees, the number
and size of required trees, and the number of proposed trees to be planted, and other
relevant features.
Soil testing results including a copy of the Geotechnical Engineer's report on the site,
and proposed method of treatment when unusual soil conditions or special foundation
problems are indicated.
Review of anticipated LEED points and certification level; adjust attempted points as
needed to meet target certification level.
Drawing(s) to include as a minimum, the following deliverables:

Floor plan drawn at an architectural scale that will allow the entire facility to be shown
on one sheet, without breaklines, and which indicates project phasing as applicable to the
Scope.
Floor plans drawn at 3/32 inch or larger scale showing typical occupied spaces or
special rooms with dimensions, sanitary facilities, stairs, elevators, identification of
accessible areas for the disabled and other program requirements.
Floor plans drawn at 3/32 inch or larger scale showing typical spaces or special rooms
with dimensions, indicating door and window layouts and other relevant features.
For alterations or additions to an existing facility: Indicate the connections and tie-ins to
the existing facilities, including all existing spaces, exits, plumbing fixtures and
locations and any proposed changes thereto. Distinguish between new and existing areas
for renovation, remodeling, or an addition and show demolition plans of areas to be
removed.
Furniture and Equipment plans drawn at 1/8 inch or larger scale showing typical spaces
or special rooms with dimensions, equipment and furnishing layouts and other relevant
features.
Reflected ceiling plans drawn at 3/32 inch or larger scale showing typical spaces or
special rooms with dimensions, major lighting equipment and ceiling panel layouts.
31 ARCHITECTURE DEVELOPMENT
A-105
STAGE I FPID(S): 999999-1-52-01
[DATE]

Roof and miscellaneous plans to be drawn at 3/32 inch or larger scale showing
dimensioned features penetrations, equipment and other relevant features.
Plumbing fixture locations and fixture unit calculations, isometrics, one line diagram and
riser details, schedule of common fixtures and other relevant features.
All exterior building elevations to illustrate and indicate the scale, finish, size and
fenestration of the facility.
Sufficient building and wall sections to show dimensions, proposed construction
material, and relationship of finished floor to finished grades.
Preliminary Structural Drawings to include plans and sections indicating systems,
connections and foundations.
Mechanical Drawings to include ceiling plans with a single line duct layout, location of
grease trap(s), LP gas tank location, natural gas piping to existing utilities. Provide
narrative description to include a description of proposed HVAC system equipment
including the chiller, pumps, AHUs, cooling tower, electric duct heaters and other
relevant features.
Electrical Drawings include plans with lighting layouts for outdoors and major interior
spaces and electrical outlets for all major spaces. Show location of electrical rooms,
transformers, emergency generator. Also show locations of mechanical equipment such
as chillers, compressors and air handler units and their respective electrical connections
and other relevant features.
Equipment and Furnishing Schedules to indicate major equipment that will be provided
by the Contractor and those that will be provided by the DEPARTMENT or others.
Life-Safety plans to show exit strategy, rated doors, emergency wall openings, range and
fume hoods, eye wash, emergency showers, ramps, vertical lifts, and other relevant features.

By symbol, indicate fire extinguishers, fire alarm equipment, smoke vents, master valves
and emergency disconnects, emergency lighting, emergency power equipment, fire
sprinklers, exit signs, smoke and fire dampers, and other life-safety equipment relevant
to the facility.
By symbol, indicate connections and tie-ins to existing equipment.
For existing facilities where remodeled or renovated spaces are required and where an ADA
and code conforming ramp cannot be utilized, document proposed vertical platform lifts or
inclined wheelchair lifts and provide the following documents as part of or in addition to the
required life safety plans:

Floor plans of proposed vertical platform lifts including layout drawings showing
corridor widths and exiting from the affected facility.
Sketches of proposed inclined wheel chair lift to include layout drawings showing clear
and affected areas of the following conditions stairway width in the folded and unfolded
position, the upper and lower platform storage locations, and the means of egress from
the affected areas of the facility.
Outline Specifications

Organized to conform to the formats for outline specifications as established by the


Construction Specifications Institute's current edition of Master Format on the date of

31 ARCHITECTURE DEVELOPMENT
A-106
STAGE I FPID(S): 999999-1-52-01
[DATE]

execution of the Contract.


Complete for Divisions 2 through 16 for finishes, material, and systems including
structural, HVAC, electrical, plumbing and specialty items, including fire sprinklers,
alarm systems, electronic controls and computer networking components.
Other Requirements

Provide a Life-Cycle Cost Analysis (LCCA) for review and approval. LCCA shall be by
a commercially available life-cycle cost analysis program and as required by the State of
Florida and the DEPARTMENT.
Deign to meet or exceed Florida Energy Efficiency Code for Building Construction
(FEEC). Submit completed FEEC forms, including calculations for mechanical systems,
documenting energy efficiency ratio rating of HVAC equipment, electrical systems,
insulation, and building envelope shall be submitted to the DEPARTMENT for review
and approval.
The Design Professional shall advise the DEPARTMENT of any adjustments to the
budget and shall submit a fully detailed Phase I estimate of probable construction cost,
projected to the expected time of bid and containing sufficient detail to provide
information necessary to evaluate compliance with the Construction Budget set for this
project. Format estimate and provide detail matching the organization and content of the
project's Outline Specifications complete for Divisions 2 through 16.
Provide an updated Project Development Schedule reflecting development and
anticipated schedules for all subsequent project activities.
A letter indicating, the extent of any known or suspected asbestos containing materials or
other potentially hazardous materials which might require mitigation by the Owner prior
to or during construction of the Project. Establish and confirm responsibility for
removing the asbestos or other hazardous materials in the design development
documents and coordinate with Project Development Schedule, Statement of Probable
Construction Cost and other documentation.
Preliminary color boards to review two color selection schemes.
Staff from each of the Design Professional's major technical disciplines, and subconsultants
shall attend coordination, review and presentation meetings with the Owner to explain the
design concept and technical resolution of their respective building or site systems.

The Design Professional shall submit five (5) sets of all documents required under this phase
without additional charge, for approval by the Owner. The Design Professional shall not
proceed with the next phase until the completion of all required presentations and reports
and receipt of a written Authorization to Proceed with the next phase.

PHASE II - 60% DOCUMENTS:

After written Authorization to Proceed from DEPARTMENT and based on the approved
Phase I documents, and any adjustments in the scope or quality of the project or in the Fixed
Limit of Construction Cost authorized by DEPARTMENT, the Design Professional shall
prepare for approval by DEPARTMENT, Phase II (60% Construction) Documents setting
forth in detail the requirements for the construction of the Project. The Design Professional
is responsible for the full compliance of the design with all applicable codes. Phase II
31 ARCHITECTURE DEVELOPMENT
A-107
STAGE I FPID(S): 999999-1-52-01
[DATE]

documents comprised of, but not limited to, the following:

Documents

Updated Florida Energy Efficiency Code for Building Construction (FEEC) compliance
forms.
Calculations: Provide preliminary calculations for structural, mechanical and electrical
systems.
Review of anticipated LEED points and certification level; adjust attempted points as
needed to meet target certification level.
Drawings

Site Plan(s) and detailing which, in addition to the Phase I requirements, indicate the
following:

Spot elevations, based on the civil grading plan, for the perimeter of the new
construction, sidewalk, or any other areas pertinent to the drainage of rainwater.
Location of storm water service for new construction roof drainage.
Parking lot lighting poles, location and type.
Final location for manholes, handholds, and pull boxes.
Layout of underground distribution systems (normal power emergency power, fire alarm,
master clock, intercommunication, television, telephone, security, control and spares).
Locations of all site improvements, playground and equipment, street furniture, planters
and other features.
Details of all curbing, typical parking spaces (regular and handicap accessible), handicap
ramps, directional signage, site lighting, flagpole and fence foundations, and any other
site conditions pertinent to the scope of work.
A plan to delineate staging areas, site barriers, and other area designations to control the
public from construction activities and traffic.

Landscape plans and details including, a plant list clearly noted and cross-referenced, details
for shrub and tree plantings, identification of plants and trees to remain, to be removed or
relocated, and other necessary documentation.

Irrigation plans and details delineating the entire area of the project, and addressing
necessary connections, alteration, repair or replacement of any existing irrigation.

Floor plans to include the following:

All dimensions and any cross references explaining the extent of work, wall types, or
other component, assembly or direction regarding the Construction.
Wall chases, floor drains and rainwater leaders.
Show structural tie columns and coordinate with the floor plan.
Cross referenced interior elevations.
Delineate and note all built-in cabinetry or equipment.
Identify room and door numbers with all doors having individual numbers.

31 ARCHITECTURE DEVELOPMENT
A-108
STAGE I FPID(S): 999999-1-52-01
[DATE]

Demolition Plans

Indicate required demolition activities.

Provide separate demolition plan(s) and other drawings (elevations, sections, etc.) if the
scope of work includes demolition which is too excessive to indicate in drawings
depicting new construction.
Indicate notes on the extent of the demolition: address dimensions at locations where
partial walls are being removed or altered, existing room names and numbers, existing
partitions, equipment, plumbing, HVAC or electrical elements,
Include notes dealing with protection of existing areas as a result of demolition.
Delineate any modifications to existing buildings involving structural elements within
the structural documents rather than on the architectural.
Building elevations developed further than at Phase II and including delineation of building
joints (including dimensionally located stucco control joints), material locations, elevation
height, and other building features.

Building and wall sections to establish vertical controls and construction types. Include clear
graphic, and notes on construction assemblies and systems to be used, dimensions, heights.
Provide, associated detailing to delineate solutions for difficult connections.

Reflected ceiling plans to indicate ceiling types, heights, ceiling grid layout, light fixture
types, mechanical diffuser and return location, and sprinkler heads if area is sprinklered.
Delineate and detail any dropped soffits or joint conditions between different materials.
Coordinate with architectural, electrical, mechanical, and plumbing disciplines.

Roof Plans

Indicate all roof penetrations, including drains, scuppers, exhaust fans, and any other
equipment on the roof. Show direction of roof slopes with elevations at the high and low
points, type of roofing system to be used, expansion joints, typical parapet, and flashing
details.
Provide dimensions to locate all penetrations and cross-reference details.
Large scale building details as appropriate to this level of document development and as
required to establish vertical controls for the Project. Include clear graphics and notes on
construction assemblies and systems to be used, and dimensions and heights. Provide
associated detailing to delineate solutions for difficult connections.

Interior elevations of all rooms including cross references of cabinetry details, dimensions
and heights, notes indicating type of equipment (and whether equipment is in or out of
contract), wall materials, finishes, and classroom equipment, and accessories.

Details of casework as necessary to appropriately delineate custom or pre-manufactured


casework. Provide appropriate schedules referencing manufacturer's numbers or catalogs,
finishes, hardware, and other construction characteristics.

31 ARCHITECTURE DEVELOPMENT
A-109
STAGE I FPID(S): 999999-1-52-01
[DATE]

Details of the following:

Door jamb, head and sill conditions.


Wall and partition types.
Window head, sill and jamb conditions, and anchorage methods shown, in lieu of
referencing to manufacturer's standards.
Interior signage to include classroom and building identification, emergency exiting and
equipment signs, and any other items pertinent to the identification of the project.
Coordinate with electrical discipline.
Interior and exterior expansion control connections.
Any other specialized items necessary to clearly express the intent of the project design.
Room finishes and door schedules coordinated with the floor plans, developed to 60%
completion.

Structural foundation and framing plans, with associated diagrams, schedules, notes,
detailing and section drawings completed sufficiently to communicate the design intent and
coordination with other disciplines.

Mechanical Drawings

Provide double line ductwork layout and HVAC equipment layout drawings with related
diagrams and schematic diagrams, schedules, notes, detailing and section drawings
completed sufficiently to communicate the design intent and coordination with other
disciplines.
Provide plumbing equipment, and fixture drawings with related diagrams, schedules,
notes, detailing and section drawings completed sufficiently to communicate the design
intent and coordination with other disciplines.
Provide dimensioned 1/2 inch scale plans, elevations and sections of the mechanical
rooms showing service, clearance, room openings, nominal equipment size, ceiling
height, duct clearance between bottom of joist and top of ceiling and any ceiling
mounted lighting fixtures, electrical equipment or other building assembly or
component, etc.
Electrical

Provide drawings for the following systems:

Lighting including, circuiting and luminaire identification and switching. Also provide
illuminance computer print out for all indoor typical indoor spaces and parking lots.
Convenience outlets and circuiting, special outlets and circuiting, and power systems and
equipment. Provide riser diagrams for all electrical systems including master clock,
intercom, fire alarm, ITV, computer networking/telephone. Also, provide for emergency
and normal power distribution. Provide light fixture schedule.
Panel schedule may be in preliminary form but circuitry must be included.
Applicable installation details.
General legend and list of abbreviations.
Voltage drop computations for all main feeders.

31 ARCHITECTURE DEVELOPMENT
A-110
STAGE I FPID(S): 999999-1-52-01
[DATE]

Short circuit analysis


Provide 1/2" scale floor plan and wall elevations for all electrical rooms.
Indicate surge protector for main switchboard and electrical panels.
Specifications

Provide preliminary Project Manual including front-end documents. Completion of


fill-in items in Bidding documents and other "Division 0"documents is not required.
Provide a preliminary Division 1 based upon the standard documents provided by the
Owner and edited by the Design Professional after consultation with the Owner to
establish project specific requirements.
Include progress set of all other Sections in Divisions 2-16 with each section developed
to demonstrate to the Owner an understanding of the project and an appropriate level of
developmental progress comparable to that of the drawings.
Specification sections shall be organized to follow the Construction Specification
Institute's (CSI) current edition of Master Format with each section developed to include
CSIs standard 3-part section and page formats with full paragraph numbering.
An updated Project Development Schedule, formatted as a preliminary construction
schedule reflecting continued Project development and illustrating anticipated schedules for
all subsequent project activities including permitting and submittal coordination with all
agencies having jurisdiction on the Project, project phasing, site, mobilization, temporary
facilities, general construction sequencing, anticipated substantial completion dates,
DEPARTMENT occupancy, and all other significant Project events.

Colorboards illustrating color selections, finishes, textures and aesthetic qualities for all
finish materials for final review and approval by the DEPARTMENT, and to establish a final
palette of material selections for development of subsequent specifications, schedules and
other requirements for incorporation into the Contract Documents.

A letter from the Design Professional and each of the major technical disciplines and any
necessary subconsultants or explaining how each previous comment concerning the project
has been addressed or corrected.

Staff from each of the Design Professional's major technical disciplines, and subconsultants
shall attend coordination, review and presentation meetings with the Owner to explain the
design concept and technical resolution of their respective building or site systems.

The Design Professional shall submit five (5) sets of all documents required under this phase
without additional charge, for approval by the Owner. The Design Professional shall not
proceed with the next phase until the completion of all required presentations and reports
and receipt of a written Authorization to Proceed with the next phase.

PHASE III - 100% CONSTRUCTION DOCUMENTS SUBMITTAL

After written Authorization to Proceed from DEPARTMENT and based on the approved
Phase II documents and any adjustments in the scope or quality of the project or in the Fixed
Limit of Construction Cost authorized by DEPARTMENT, the Design Professional shall

31 ARCHITECTURE DEVELOPMENT
A-111
STAGE I FPID(S): 999999-1-52-01
[DATE]

prepare for approval by DEPARTMENT, Phase III (100% Construction) Documents setting
forth in detail the requirements for the construction of the Project. The Design Professional
is responsible for the full compliance of the design with all applicable codes. Phase III
documents are to be comprised of, but not limited to, the following:

General Requirements

Updated Florida Energy Efficiency Code for Building Construction (FEEC) compliance
forms. Submit five (5) copies signed and sealed by a State of Florida registered design
professional.
Signed and Sealed/Statements of Compliance: Only complete documents, properly
signed and sealed by the Project Consultant and respective subconsultants, will be
accepted for review; in addition, these documents shall contain a statement of
compliance by the architect or engineer of record as follows: "To the best of my
knowledge and belief these drawings, and the project manual are complete, and comply
with the Department of Transportation Requirements".
Submit engineering calculations for mechanical, electrical, and structural systems in a
separately bound manual.
Review of anticipated LEED points and certification level; adjust attempted points as
needed to meet target certification level.
Drawings

The drawings shall include all previous phase review requirements, and the Phase III 100%
document requirements specified above, along with the following:

Site plans including, but not limited to, area location map, legal description of property,
demolition, excavation, utilities, finish grading, landscaping, mechanical, electrical,
civil/structural, and architectural site plans:
Drawings include at a minimum, the following:
Key sheets including a table of contents and statement of compliance by the design
professional. Each discipline shall have a list of abbreviations, schedule of material
indications, and schedule of notations and symbols at the beginning of their section of
the plans.
Architectural drawings including floor plans, door, window and finish schedules, roof
plans, elevations, sections, and details.
Civil/Structural drawings including paving, traffic loops, service drives, parking;
drainage; foundation plans; floor plans; roof plans; structural plans; sections; details;
and, pipe, culvert, beam and column schedules.
Mechanical drawings including floor plans; sections; details; riser diagrams; kitchen
exhaust hoods; and, equipment, fan, and fixture schedules.
Electrical drawings including floor plans; sections; details; riser diagrams, and fixture
and panel schedules.
The drawings should indicate that the approved mechanical/electrical systems, from the
previous phases FEEC/LCCA analysis, have been incorporated into the documents.
Staff from each of the Design Professional's major technical disciplines, and subconsultants
shall attend coordination, review and presentation meetings with the Owner to explain the
31 ARCHITECTURE DEVELOPMENT
A-112
STAGE I FPID(S): 999999-1-52-01
[DATE]

design concept and technical resolution of their respective building or site systems.

The Design Professional shall submit five (5) sets of all documents required under this phase
without additional charge, for approval by the Owner. The Design Professional shall not
proceed with the next phase until the completion of all required presentations and reports
and receipt of a written Authorization to Proceed with the next phase.

PHASE IV FINAL CONSTRUCTION DOCUMENTS SUBMITTAL:

After written Authorization to Proceed from DEPARTMENT and based on the approved
Phase III documents and any adjustments in the scope or quality of the project or in the
Fixed Limit of Construction Cost authorized by DEPARTMENT, the Design Professional
shall prepare for approval by DEPARTMENT, Phase IV (Final Construction) Documents
setting forth in detail the requirements for the construction of the Project: The Design
Professional is responsible for the full compliance of the design with all applicable codes.
Phase IV documents are to be comprised of, but not limited to, the following:

General Requirements

This submittal is the official record set and shall be the bid documents.
Signed and Sealed/Statements of Compliance: Only complete documents, properly
signed and sealed by the Project Consultant and respective subconsultants, will be
accepted for review; in addition, these documents shall contain a statement of
compliance by the architect or engineer of record as follows: "To the best of my
knowledge and belief these drawings, and the project manual are complete, and comply
with the DEPARTMENT of Transportation Requirements".
Submit engineering calculations for mechanical, electrical, and structural systems in a
separately bound manual.
Update anticipated LEED points and certification level; adjust attempted points as
needed to meet target certification level.
Drawings

The drawings shall include all previous phase review requirements, and the Phase IV final
document requirements specified above, along with the following:

Site plans including, but not limited to, area location map, legal description of property,
demolition, excavation, utilities, finish grading, landscaping, mechanical, electrical,
civil/structural, and architectural site plans:
Drawings include at a minimum, the following:
Key sheets including a table of contents and statement of compliance by the design
professional. Each discipline shall have a list of abbreviations, schedule of material
indications, and schedule of notations and symbols at the beginning of their section of
the plans.
Architectural drawings including floor plans, door, window and finish schedules, roof
plans, elevations, sections, and details.
Structural drawings including foundation plans; floor plans; roof plans; structural plans;
sections; details; and, beam and column schedules.
31 ARCHITECTURE DEVELOPMENT
A-113
STAGE I FPID(S): 999999-1-52-01
[DATE]

Mechanical drawings including floor plans; sections; details; riser diagrams; kitchen
exhaust hoods; and, equipment, fan, and fixture schedules.
Electrical drawings including floor plans; sections; details; riser diagrams, and fixture
and panel schedules.
The drawings should indicate that the approved mechanical/electrical systems, from the
previous phases FEEC/LCCA analysis, have been incorporated into the documents.
Upon completion of the Final Construction Documents, the Design Professional shall submit
to the Owner five (5) copies of the Drawings, Specifications, reports, programs, a final up
dated Project Development Schedule, a final up-dated Statement of Probable Construction
Cost and such other documents as reasonably required by Owner.

All documents for this phase shall be provided in both hard copy and in electronic media.
The DEPARTMENT will approve Phase IV documents for submission to the
DEPARTMENT for review and approval.

Architectural Plans

31.1 Architectural Program Review/Verification

31.2 Key Sheet and Index of Sheets

31.3 General Notes, Abbreviations, Symbols, and Legend

31.4 Life Safety Plan(s)

31.5 Site Plan(s)

31.6 Floor Plan(s) (small scale)

31.7 Floor Plan(s) (large scale)

31.8 Exterior Elevation(s)

31.9 Roof Plan(s)

31.10 Roof Details

31.11 Interior Elevation(s)

31.12 Rest Room Plan(s) (Enlarged)

31.13 Rest Room Elevation(s)

31.14 Building Section(s)

31.15 Stair Section, Enlarged Stair Plan and Details

31.16 Reflective Ceiling Plan(s)

31 ARCHITECTURE DEVELOPMENT
A-114
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.17 Room Finish Schedule or Finish Plan

31.18 Door and Window Finish Schedule

31.19 Door Jamb Detail(s) and Window Details

31.20 Exterior Wall Section(s)

31.21 Interior Wall Section(s)

31.22 Overhead Door Detail(s)

31.23 Curtain Wall Detail(s)

31.24 Fascia, Soffit and Parapet Details

31.25 Signage Detail(s)

31.26 Miscellaneous Detail(s)

31.27 Repetitive Sheets

31.28 Design Narrative Reports

31.29 Permitting

31.30 Other Pertinent Project Documentation

31.31 Cost Estimate

31.32 Technical Special Provisions Package

31.33 Field Reviews

31.34 Technical Meetings

31.34.1 FDOT

31.34.2 Local Governments (cities)

31.34.3 Local Governments (counties)

31.34.4 Other Meetings

31.34.5 Progress Meetings

31.34.6 Phase Review Meetings

31.35 Quality Assurance/Quality Control

31 ARCHITECTURE DEVELOPMENT
A-115
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.36 Meeting with Independent Peer Review

31.37 Supervision

Structural Plans

31.38 General Notes, Abbreviations, Symbols, and Legend

31.39 Foundation Plan(s) (Small Scale)

31.40 Foundation Plan(s) (Large Scale)

31.41 Slab Plan(s) (Small Scale)

31.42 Slab Plan(s) (Large Scale)

31.43 Slab Placement Plan(s)

31.44 Slab Placement Detail(s)

31.45 Foundation Section(s)

31.46 Foundation Detail(s)

31.47 Slab Section(s)

31.48 Slab Detail(s)

31.49 Roof Framing Plan(s) (Small Scale)

31.50 Roof Framing Plan(s) (Large Scale)

31.51 Roof Loading Plan(s) and Detail(s)

31.52 Roof Section(s)

31.53 Roof Detail(s)

31.54 Bearing Wall Section(s)

31.55 Bearing Wall Detail(s)

31.56 Column Section(s)

31.57 Column Detail(s)

31.58 Miscellaneous Sections

31.59 Repetitive Sheets

31 ARCHITECTURE DEVELOPMENT
A-116
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.60 Other Pertinent Project Documentation

31.61 Cost Estimate

31.62 Technical Special Provisions Package

31.63 Field Reviews

31.64 Technical Meetings

31.64.1 FDOT

31.64.2 Local Governments (cities)

31.64.3 Local Governments (counties)

31.64.4 Other Meetings

31.64.5 Progress Meetings

31.64.6 Phase Review Meetings

31.65 Quality Assurance/Quality Control

31.66 Independent Peer Review

31.67 Supervision

Mechanical Plans

31.68 General Notes, Abbreviations, Symbols, Legend, and Code Issues

31.69 Plan(s) (Small Scale)

31.70 Plan(s) (Large Scale)

31.71 Detail(s)

31.72 Section(s)

31.73 Piping Schematic(s)

31.74 Control Plan(s)

31.75 Schedule(s)

31.76 HVAC Calculations

31.77 Life Cycle Cost Analysis

31 ARCHITECTURE DEVELOPMENT
A-117
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.78 Repetitive Sheets

31.79 Other Pertinent Project Documentation

31.80 Cost Estimate

31.81 Technical Special Provisions Package

31.82 Field Reviews

31.83 Technical Meetings

31.83.1 FDOT

31.83.2 Local Governments (cities)

31.83.3 Local Governments (counties)

31.83.4 Other Meetings

31.83.5 Progress Meetings

31.83.6 Phase Review Meetings

31.84 Quality Assurance/Quality Control

31.85 Independent Peer Review

31.86 Supervision

Plumbing Plans

31.87 General Notes, Abbreviations, Symbols, Legend, and Code Issues

31.88 Plan(s) (Small Scale)

31.89 Plan(s) (Large Scale)

31.90 Isometric(s) (Large Scale)

31.91 Riser Diagram(s)

31.92 Detail(s)

31.93 Repetitive Sheets

31.94 Other Pertinent Project Documentation

31.95 Cost Estimate

31 ARCHITECTURE DEVELOPMENT
A-118
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.96 Technical Special Provisions Package

31.97 Field Reviews

31.98 Technical Meetings

31.98.1 FDOT

31.98.2 Local Governments (cities)

31.98.3 Local Governments (counties)

31.98.4 Other Meetings

31.98.5 Progress Meetings

31.98.6 Phase Review Meetings

31.99 Quality Assurance/Quality Control

31.100 Independent Peer Review

31.101 Supervision

Fire Protection Plans

31.102 General Notes, Abbreviations, Symbols, Legend, and Code Issues

31.103 Fire Protection Plan

31.104 Riser Diagram, Details, and Partial Plans

31.105 Hydraulic Calculation

31.106 Repetitive Sheets

31.107 Other Pertinent Project Documentation

31.108 Cost Estimate

31.109 Technical Special Provisions Package

31.110 Field Reviews

31.111 Technical Meetings

31.111.1 FDOT

31.111.2 Local Governments (cities)

31.111.3 Local Governments (counties)


31 ARCHITECTURE DEVELOPMENT
A-119
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.111.4 Other Meetings

31.111.5 Progress Meetings

31.111.6 Phase Review Meetings

31.112 Quality Assurance/Quality Control

31.113 Independent Peer Review

31.114 Supervision

Electrical Plans

31.115 General Notes, Abbreviations, Symbols, Legend, and Code Issues

31.116 Electrical Site Plan

31.117 Lighting Plan(s)

31.118 Lighting Fixtures Schedule(s)

31.119 Lighting Fixtures Detail(s)

31.120 Lightning Protection Plan(s)

31.121 Lightning Protection Details

31.122 Power Plan(s)

31.123 Power Distribution Riser Diagram(s)

31.124 Panel Board Schedule(s)

31.125 Data Plan(s)

31.126 Data Detail(s)

31.127 Communication Plan(s)

31.128 Communication Detail(s)

31.129 Security Alarm System Plan(s)

31.130 Miscellaneous Detail(s)

31.131 Repetitive Sheets

31.132 Energy Analysis

31 ARCHITECTURE DEVELOPMENT
A-120
STAGE I FPID(S): 999999-1-52-01
[DATE]

31.133 Other Pertinent Project Documentation

31.134 Cost Estimate

31.135 Technical Special Provisions Package

31.136 Field Reviews

31.137 Technical Meetings

31.137.1 FDOT

31.137.2 Local Governments (cities)

31.137.3 Local Governments (counties)

31.137.4 Other Meetings

31.137.5 Progress Meetings

31.137.6 Phase Review Meetings

31.138 Quality Assurance/Quality Control

31.139 Independent Peer Review

31.140 Supervision

31.141 LEED Certification

31.142 Coordination

31.143 Building Information Modeling (BIM)

31 ARCHITECTURE DEVELOPMENT
A-121
STAGE I FPID(S): 999999-1-52-01
[DATE]

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE

The CONSULTANT shall fulfill the commitments resulting from the traffic noise analysis
and noise barrier evaluation performed during the Project Development and Environment
(PD&E) Phase, as directed and clarified by the DEPARTMENT.

The noise analysis shall be performed in accordance with the FDOTs Noise Policy (Part 2,
Chapter 17 of the FDOTs PD&E Manual) and the FDOTs Traffic Noise Modeling and
Analysis Guidelines. The noise analysis and noise abatement evaluation shall be performed
by or supervised/reviewed by a person(s) who has attended the Departments Traffic Noise
Analysis training course or has attended and successfully completed the National Highway
Institutes Highway Traffic Noise Course (FHWA-NHI-142051). The Federal Highway
Administration (FHWA) approved noise model, the Traffic Noise Model (TNM) Version 2.5
(or most current version) shall be used for the noise analysis, unless otherwise directed by
the DEPARTMENT.

32.1 Noise Analysis

The CONSULTANT shall review the preferred PD&E alternative to identify any design
changes that would require a reanalysis of traffic noise. Coordination will be held with the
District Environmental Management Office, prior to initiating any reanalysis, to discuss
possible effects of design changes on the validity of in the noise study performed during
PD&E.

The CONSULTANT shall perform a land use review to identify noise sensitive sites that
may have received a building permit subsequent to the PD&E noise study but prior to the
Date of Public Knowledge (DPK), or to identify areas where the land use may have changed
or is subject to change. New noise sensitive sites meeting DPK requirements that were not
considered during the PD&E phase will be subject to a traffic noise analysis to be performed
by the CONSULTANT. Additionally, noise sensitive sites analyzed in the PD&E phase may
have to be re-analyzed if affected by design changes.

The CONSULTANT shall review any commitments made during the PD&E phase regarding
possible traffic noise impacts to special use locations. Analysis of special use locations shall
be performed using the DEPARTMENTs A Method to Determine Reasonableness and
Feasibility of Noise Abatement at Special Use Locations document and shall be
coordinated with the District Environmental Management Office.

The CONSULTANT shall review the commitments made during the PD&E phase regarding
noise barrier concepts determined to be potentially feasible and reasonable. The
CONSULTANT will update the analysis of feasibility and reasonableness for noise barriers
recommended for further consideration during the design phase and for any additional noise
barriers required, using design information (e.g., profile data, horizontal alignment data, etc.)
and incorporate into the analysis any new conditions or additional costs related to noise
barrier construction that have been identified during design. A design phase noise analysis
will be performed at any additional locations required (based on DPK requirements or
roadway design changes). Additional survey may also be required at proposed barrier
locations.

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE


A-122
STAGE I FPID(S): 999999-1-52-01
[DATE]

Changes to, or fulfillment of, the original noise abatement commitments made during PD&E
shall be documented in a Noise Study Report (NSR) Addendum to be prepared by the
CONSULTANT in coordination with the District Environmental Management Office. A
copy of the final NSR Addendum shall be provided to the District Environmental
Management Office.

Traffic Data: The CONSULTANT shall review the traffic data obtained during the PD&E
phase to determine if the data remains valid for design phase reanalysis. If the traffic data is
no longer valid, the CONSULTANT shall provide to the noise analyst the following data for
each road segment (i.e. intersection to intersection) for the design year with the proposed
improvements to the road:

Level of Service C (LOS C) directional volumes


Demand peak hour volumes (peak and off-peak directions)
Posted speed
Percentage of heavy trucks (HT) in the design hour
Percentage of medium trucks (MT) in the design hour
Percentage of buses in the design hour
Percentage of motorcycles (MC) in the design hour
With the exception of LOS C volumes, the data above shall also be provided for all
interchange/highway ramps. The District Noise Specialist may also identify cross streets for
which the same data is necessary. (e.g., a cross street for which noise sensitive sites are in
close proximity to the project). The CONSULTANT shall contact the District Noise
Specialist for direction on the format to be used for providing the traffic data and any
requirements regarding approval of the data prior to its use for noise analysis. The traffic
data to be used in the noise analysis must be generated by a qualified traffic engineer/planner
who works for the DEPARTMENT or is a DEPARTMENT consultant.

32.2 Noise Barrier Evaluation

The CONSULTANT will present the data along with recommendations to the
DEPARTMENT for selection of the noise barriers locations, barriers heights and lengths to
be incorporated into the design plans. These recommendations shall consider the noise
barrier feasibility and reasonableness.

An evaluation of proposed noise barriers will be performed to identify any engineering


conflicts or constraints. The CONSULTANT will be responsible for documenting any
resolutions to engineering conflicts or issues that require modification to or preclude
construction of a noise barrier. At a minimum, the engineering review will consider the
following:

Right of way needs including access rights (air, light, view, ingress/egress,
outdoor advertising conflicts)
Limited access issues
Necessary construction and maintenance easements
Safety issues (e.g., line of sight)
Maintenance issues
Structural and vegetative restrictions within easement
Utility conflicts
Drainage issues

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE


A-123
STAGE I FPID(S): 999999-1-52-01
[DATE]

Environmental issues
Other criteria as applicable
The CONSULTANT shall re-analyze noise barrier(s) for feasibility and reasonableness and
re-establish barrier height and length if design constraints require alteration in a barriers
location or dimensions.

After reestablishing the recommended height and length of the barrier(s), the
CONSULTANT shall coordinate with design engineers and the District Planning and
Environmental Office to include the barrier(s) on the design plans. In addition, the
CONSULTANT will present a memo to the DEPARTMENT Project Manager containing a
recommendation for selection of the barrier height and length to be carried forward for
public input. This recommendation shall consider amount of noise reduction provided,
engineering constraints and cost (reasonableness). In addition, the CONSULTANT will also
consider the overall visual appearance in relation to the existing and proposed site
conditions. This includes smoothing the profile along the top of a noise barrier to the extent
possible while minimizing any loss in the amount of noise reduction provided and extending
the ends of a noise barrier to cover additional receivers. Extending the ends of a noise
barrier will not exceed the cost criteria and will only be performed when it is appropriate and
in the public interest.

32.3 Public Involvement

If noise barriers are determined to be feasible and cost reasonable, the CONSULTANT shall
carry out the public involvement and surveys necessary to report to the DEPARTMENT
whether or not the majority of the impacted and/or benefited receptors desire the
construction of a noise barrier. Input shall also be obtained from the public regarding barrier
aesthetics (color and texture) on one or both sides of the barrier. The CONSULTANT shall
be responsible for coordinating with local government officials.

As a minimum, the following tasks shall be completed by the CONSULTANT for public
involvement purposes:

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE


A-124
STAGE I FPID(S): 999999-1-52-01
[DATE]

Identification of impacted and/or benefited property owners


Identification of renters and non-residing property owners (for a property that
may be rented)
Preparation of a mailing list (property owners, renters and non-residing property
owners)
Preparation of a summary package (including an information letter, aerial
showing the noise barrier location and a survey form to document the recipients
position to be sent to property owners, and occupants/non-residing property
owners informing them of the proposed noise barrier
If necessary, preparation of additional mailings and/or door-to-door/telephone
surveys until a majority decision is obtained or until directed by the District
Noise Specialist
Tallying of survey results
Noise barrier aesthetics coordination
Public meetings coordination (including arranging the meeting location,
advertisements, displays, etc.)
Responding to public inquiries on an individual basis in coordination with the
DEPARTMENT.
The CONSULTANT shall bring to the attention of the DEPARTMENT unforeseen
conditions and issues which are relevant to the project decision. Other than noise barrier
length, height and location, the CONSULTANT shall abstain from indicating preferences for
any of the barrier options prior to or during contact with the property owners unless
specifically requested to do so by the DEPARTMENT. Following the public involvement
process, the CONSULTANT shall produce a final noise barrier recommendation that
identifies the starting and ending points for all noise barriers, the top elevation(s), and the
aesthetic elements to be provided (e.g. color, texture, graphics).

32.4 Outdoor Advertising Identification

The CONSULTANT shall identify potential noise barriers that may block the view of an
existing lawfully erected sign that is governed by and conforms to state and federal
requirements for land use, size, height and spacing consistent with the requirements of
Florida Statute (FS) 479.25 and the FDOT Noise Policy (Part 2, Chapter 17 of the PD&E
Manual). The CONSULTANT shall notify the Departments Project Manager of a potential
noise barrier(s) that may affect the visibility of a legally permitted outdoor advertising sign.
Resolution of the potential conflict shall be documented in the NSR and included in the
environmental document.

32.5 Noise Study Report (NSR) Addendum

The results of noise barrier evaluations performed by the CONSULTANT shall be


documented in the NSR Addendum (in accordance with Chapter 32 of the FDOTs Plans
Preparation Manual (PPM)) and shall include the results of the computer modeling
(electronically), public involvement activities and final noise abatement commitments.

32.6 Technical Meetings

Prior to proceeding with the noise barrier analysis, the CONSULTANT shall discuss and
coordinate with the appropriate District Project Manager and the District Environmental

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE


A-125
STAGE I FPID(S): 999999-1-52-01
[DATE]

Management Office staff. The purpose of this discussion will be for the DEPARTMENT to
provide the CONSULTANT with all pertinent project information and to confirm the
methodologies to be used to conduct the noise analysis. This meeting is mandatory and
should occur after the Notice to Proceed is given to the CONSULTANT. It is the
responsibility of the CONSULTANT to undertake the necessary action (i.e. phone calls,
meetings, correspondence, etc. to ensure that District Project Manager and the District
Environmental Management Office staff is kept informed of the noise analysis efforts so that
these tasks are accomplished in a manner that will enhance the overall success of the project.

32.7 Quality Assurance/Quality Control

QA/QC reviews will be performed for all NSR Addendums submitted to the
DEPARTMENT. Documentation of the QA/QC will be provided to the District Project
Manager.

The CONSULTANT shall ensure that the noise barrier(s) location(s), length, height and
aesthetics as shown on the final design plans are consistent with the results of the noise
barrier evaluation and recommendation documented in the original NSR and/or the NSR
Addendum.

32.8 Supervision

32.9 Coordination

32 NOISE BARRIERS IMPACT DESIGN ASSESSMENT IN THE DESIGN PHASE


A-126
STAGE I FPID(S): 999999-1-52-01
[DATE]

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS

The CONSULTANT shall analyze and document Intelligent Transportations System (ITS)
Analysis Tasks in accordance with all applicable manuals, guidelines, standards, handbooks,
procedures, existing ITS standard operating procedures, strategic plans, Floridas SEMP
guidelines, National and regional ITS architectures, and current design memoranda.

ITS work includes the application of sensor, computer, electronics and communication
technologies and management strategies, in an integrated manner, to improve the safety and
efficiency of the surface transportation system. ITS includes, but is not limited to, Advanced
Traffic Management Systems (ATMS), Advanced Traveler Information Systems (ATIS),
Advanced Rural Transportation Systems (ARTS), Advanced Public Transportation Systems
(APTS), Advanced Highway Systems (AHS), Commercial Vehicle Operation (CVO) and
Electronic Toll Collection (ETC) Systems.

In instances where the CONSULTANT performs analysis or prepares the design packages
for the deployment of ITS, the CONSULTANT will not be allowed to compete as a
proposing firm, or participate as a subconsultant to a proposing firm during subsequent
advertisements involving work performed under this contract.

33.1 ITS Analysis

The CONSULTANT shall review the approved preliminary engineering report, typical
section package, traffic technical memorandum and proposed geometric design alignment to
identify impacts to existing ITS components (if applicable) and proposed ITS field device
placements. The CONSULTANT shall review all related District ITS plans and
documentation for the project corridor to ensure all cited ITS elements are included in this
project, and develop a Concept of Operations (ConOps), Project Systems Engineering
Management Plan (PSEMP), RTVM, and other documents as necessary for conformance
with Federal Highway Administration (FHWA) requirements. The CONSULTANT shall use
applicable DEPARTMENT requirements and guidelines, including, but not limited to, the
PPM, Design Standards, and Standard Specifications for Road and Bridge Construction in
the design of ITS. The CONSULTANT design is expected to include the following
attributes, facilities, infrastructure, ITS devices, systems, and associated work: [Insert
project specifics (e.g. TMC facilities; communication system design; SunGuide
software system installation or expansion; deployment of ITS device such as DMS,
CCTV cameras, vehicle detection systems, etc.)]

CCTV camera system shall provide 100 percent coverage of all mainline lanes, entrance and
exit ramps, interchanges (includes view of crossing arterials), blind spots (such as those
caused due to existing and proposed bridges, existing and proposed signage, vegetation, and
horizontal and vertical curvatures). Cameras shall be spaced to meet the Project
requirements, guidance from the ConOps, and as approved by the DEPARTMENT.

Vehicle detection devices shall be spaced as required to meet the Project requirements
(speed, volume, and occupancy detection), guidance from the ConOps and as approved by
the DEPARTMENT.

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-127
STAGE I FPID(S): 999999-1-52-01
[DATE]

Both expressway and arterial dynamic message signs (DMS) shall be located to meet the
Project requirements, guidance from the ConOps, and as approved by the DEPARTMENT.
All FDOT PPM requirements shall be met for DMS locations. DMS locations shall be
designed in conjunction with the Projects master signing design.

The CONSULTANT shall review the existing TMC Operations and develop additional
incident management service requirements as necessary to support during the Construction
Phase of the Project. The CONSULTANT shall coordinate with Districts Traffic Operations
ITS Office for additional information regarding existing Incident Management and TMC
Operational Procedures (If desired by the District).

All ITS devices shall be compatible with the latest version of the National Transportation
Communications for ITS Protocol (NTCIP) and compatible with SunGuide software
platform.

The CONSULTANT shall design the project such that all ITS field devices and ancillary
components comply with FDOTs Approved Product List (APL) and are supported within
the SunGuide software or other software approved by the DEPARTMENT.

Closed Circuit Television (CCTV) Camera Assembly

The CONSULTANT shall be responsible for the design and exact field locations for the
camera assemblies. The camera subsystem shall provide overlapping coverage to overcome
visual blockage. Camera assemblies may include a camera lowering device (CLD).

The camera subsystem shall be designed to provide additional benefits such as the
monitoring of DMS operations and security surveillance of critical infrastructure elements.
A stand-alone DMS confirmation camera shall be designed and installed to support TMC
operations to verify and confirm the posted DMS messages (if desired by the
DEPARTMENT). The position, height, and design of each camera pole shall be finalized
during the design phase of the project. Each site shall be designed for overall monitoring
capability, as well as designed to provide safe and effective maintenance conditions.

The camera assembly deployment shall be designed to provide fields of view that give the
required corridor coverage. The CONSULTANT shall determine the camera location by
performing a videography study at each proposed camera site. The study shall include video
at the proposed camera location and elevation with respect to the roadway elevation. The
CONSULTANT shall identify the final number and locations of the camera assemblies based
on the videography study.

The camera system design shall ensure that the video quality is not degraded due to wind or
vibration. The CONSULTANT shall be responsible for the design of the poles and
foundations to minimize the potential for vibration. The CONSULTANT shall prepare cross
section plan sheets showing details of horizontal and vertical clearances of the proposed
equipment with identified utilities.

The CONSULTANT shall be responsible for the design of the grounding and lightning
protection system based on FDOT criteria

The CCTV camera assembly shall comply with the latest version of FDOT Standard
Specifications for Road and Bridge Construction, Supplemental Specification 682.

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-128
STAGE I FPID(S): 999999-1-52-01
[DATE]

Vehicle Detection Subsystem

The CONSULTANT shall select vehicle detection technology to meet the Project needs,
ConOps requirements, and as approved by the DEPARTMENT.

The CONSULTANT shall be responsible for the design of a non-intrusive vehicle detection
subsystem for the roadway facilities. The detectors shall be positioned near other ITS field
device infrastructure including the fiber-optic splice vaults when feasible to reduce cost.
Final detection station locations shall be based on a number of location variables identified
during the design phase.

The vehicle detection subsystem shall collect and process volume, speed and occupancy data
on a lane-by-lane basis for the corridor mainlines, in both directions of travel. The data will
be used by the TMC for functions including detecting incidents, determining travel times,
estimating traffic conditions for dissemination to travelers, sharing information with other
agencies, and data archiving for transportation planning and historical data analysis. The
vehicle detection subsystem shall allow for connectivity to the TMC.

Vehicle detectors must meet the Project requirements under all environmental and traffic
conditions expected for the corridors. The detection system shall produce accurate volume,
speed and occupancy data for all corridor traffic operation conditions. The CONSULTANT
design must limit the likelihood of occlusions, other blocking of vehicles and adjacent lanes
detection that degrade the detection system performance below specified accuracy. Design
the system so that signs, walls, guardrails, and other physical elements do not degrade
detection performance.

The system shall allow remote configuration, calibration, monitoring, and diagnostic of real-
time traffic activities from a remote location, such as the TMC, using the FDOT SunGuide
central software and software provided by the detection system vendor.

The CONSULTANT shall determine the exact location of the field devices to meet the
desired coverage and functional requirements of vehicle detectors. The detector and
associated cabinet locations shall be identified by the CONSULTANT. The CONSULTANT
will coordinate and perform a detailed site survey with a factory trained and certified
representative of the detection system manufacturer being proposed in their design. The site
survey must confirm that the design does not exceed the operational capabilities of the
proposed detection technology or device.

The CONSULTANT shall be responsible for the design of a vehicle detection system that
allows travel times to be automatically calculated for roadway facilities. The travel time
system may utilize a variety of vehicle detection systems, including loop, video, microwave,
wireless magnetometer, and Automatic Vehicle Identification (AVI) systems. The system
shall utilize the project communications backbone in order to collect and distribute travel
time data to the TMCs.

When utilizing transponders, they will be read by AVI reader equipment placed at
checkpoints along the roadway. As a transponder passes a checkpoint, its data shall be
acquired by the AVI system. The AVI system shall automatically add the time, date,
transponder reading antenna number, and the antenna location to the transponder
identification code and store the data.

Systems that rely upon transponders shall utilize supplemental toll tag readers placed at
appropriate existing device locations as applicable, as well as interchanges and at

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-129
STAGE I FPID(S): 999999-1-52-01
[DATE]

intermediate locations throughout the project as required to provide the required coverage to
satisfy travel time measurement requirements. Using the designed communications, the
transponder information shall be forwarded to the TMC for further processing.

The CONSULTANT shall coordinate all design efforts for use of SunPass AVI transponders
with the Floridas Turnpike Enterprise (FTE) Tolls group.

The vehicle detection system utilized shall comply with the latest version of FDOT Standard
Specifications for Road and Bridge Construction, Specification 660.

Dynamic Message Sign Subsystem

The CONSULTANT shall be responsible for the design of the DMS subsystem for the
roadway facilities.

The position of each DMS shall be finalized during the design phase of the project. The
CONSULTANT shall select DMS technology, type, and display to meet the Project
requirements and ConOps requirements.

The CONSULTANT shall locate the DMS to satisfy the required sign functionality and to
provide the required visibility of the signs. The project communications system shall enable
full control of the DMS from the TMC facilities. All DMS hardware, software and related
infrastructure components shall be fully compatible with SunGuide software. All DMS shall
include a dedicated confirmation camera that allows for visual verification of the messages
posted on the DMS by a TMC Operator (if desired by the District).

The CONSULTANT shall design support structures to accommodate the specified DMS to
meet the design functional, operational, and maintenance requirements.

The DMS shall be designed in accordance with the latest version of FDOT Standard
Specifications for Road and Bridge Construction, Supplemental Specification 700.

All Highway Signing, including Dynamic Message Signs, shall comply with the latest
version of FDOT Standard Specifications for Road and Bridge Construction, Specification
700.

Roadway Weather Information Systems (RWIS)

The CONSULTANT shall develop technical special provisions for RWIS based upon the
unique needs of the project. The CONSULTANT shall ensure that, each RWIS site consists
of a remote processing unit (RPU), communication hardware, and determine the site specific
components as required from below:

Fog/Smoke Detection sensor;

Classifying Precipitation;

Precipitation Occurrence Sensor;

Air Temperature/Relative Humidity Sensor;

Wind Speed and Direction Sensor;

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-130
STAGE I FPID(S): 999999-1-52-01
[DATE]

RWIS Tower/Pole Structure, foundation, base, and cabinet with electrical service, and
lightning protection & grounding assembly; and,

Communication hardware.

The RWIS subsystem shall include all hardware, software, and licenses to operate, including
SQL database for the TMC and RWIS Central Hardware for TMC.

33.2 Communications

The CONSULTANT shall be responsible for the development of a communications plan to


determine the optimal communications medium for the project corridor. The plan shall be
developed prior to submittal of Phase I plans. The plan shall identify communications media
alternatives and provide a cost estimate that includes initial, operations and maintenance cost
for the life cycle of the communications network. The plan shall ensure that video, voice,
and data will be communicated in real-time between center-to-field and center-to-center
(C2C) nodes as applicable. The communications system design must utilize non-proprietary,
open-architecture, standards-based, robust, scalable, and proven technology. The
communication plan analysis shall address communication and connections between field
devices, communications and connections between field devices and the TMC, center-to-
center communications between TMCs, and any other communication links or connections
required to meet project goals. The plan must include bandwidth analysis and
recommendations, needs assessment, and provide recommendations regarding minimum
requirements, media, network devices, protocols, network topology, communication
redundancy, future needs, spare capacity, and any communications or data sharing with other
agencies.

After approval of the plan, the CONSULTANT shall submit a revised plan including a
detailed design analysis for each submittal. The CONSULTANTs communications design
shall include multiple redundant paths for each location, which allows for automatic
switching of communications path onto a secondary path, if the primary path is impacted (if
desired by the District).

The communications system components shall be in accordance with Sections 630, 633, and
635 of the latest FDOT Standard Specifications for Road and Bridge Construction (online
edition).

33.3 Grounding and Lightning Protection

The CONSULTANT shall be responsible for a complete and reliable grounding and
lightning protection design to provide personnel and equipment protection against faults,
surge currents and lightning transients.

The grounding and lightning protection system shall be designed in accordance with the
latest version of the FDOT Standard Specifications for Road and Bridge Construction,
Specification 620.

33.4 Power Subsystem

The CONSULTANT shall be responsible for an electrical design in accordance with all NEC
requirements. No solar power should be utilized as a power solution for the Project unless
otherwise approved by the DEPARTMENT. To enhance power reliability, the
CONSULTANT shall design a power distribution and backup system consisting of, at a
33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS
A-131
STAGE I FPID(S): 999999-1-52-01
[DATE]

minimum, underground power conduits and conductors, transformers, generators, automatic


transfer switches, UPS, and all associated equipment. The power backup system shall supply
electrical power in event of commercial power supply failure for all system components.
Power equipment shall be installed in areas to avoid wet locations. All connections and
equipment shall be protected from moisture and water intrusion. The CONSULTANT shall
ensure that vandal resistant mechanisms for all electrical infrastructure shall be included as
part of the Design.

The CONSULTANT shall submit the power system design and voltage drop calculations for
the power distribution system as part of phase II, III, and IV design submittals. The
CONSULTANT shall conduct a short circuit and protection coordination study for the
designed power system and document the study as part of the power system design report.

33.5 Voltage Drop Calculations

The electrical design shall address allowable voltage drops per the NEC. The
CONSULTANT shall submit voltage drop calculations for any electrical circuit providing
power to the ITS field devices beyond the electric utility service point. The calculations shall
document the length of each circuit, its load, the size conductor or conductors used and their
ohm resistance values and the required voltages from the service point to the respective ITS
devices to maintain voltage drops with allowable limits. The voltage drop incurred on each
circuit (total volts and percentage of drop) shall be calculated, and all work necessary to
calculate the voltage drop values for each circuit should be presented in such a manner as to
be duplicated by the District. Load analysis calculations shall be submitted. All voltage drop
calculations shall allow for future expansion of ITS infrastructure, if identified in the Project
ConOps.

33.6 Design Documentation

The CONSULTANT shall submit a Design Documentation Book with each plan submittal
under separate cover and not part of the roadway documentation book. At a minimum, the
design documentation book shall include:

Computation books for all applicable items on plans.


Phase submittal checklist.
Three-way quantity check list
Structural calculations for all structures
Voltage drop calculations.
Load analysis calculations.
33.7 Existing ITS

The CONSULTANT shall research any required legacy system or system components that
may be impacted by new work, such as: existing communications; existing types, numbers,
locations, models, manufacturers, and age of ITS devices; as-built plans; existing operating
software; existing center-to-field devices; and C2C communications and capabilities.

33.8 Queue Analysis

The CONSULTANT shall perform a queue analysis at high volume interchanges and high
frequency conflict / crash locations to determine optimal placement of DMS using project
forecasted traffic volumes. This analysis shall be performed prior to submittal of the Phase I

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-132
STAGE I FPID(S): 999999-1-52-01
[DATE]

plans. The Consultant shall perform other traffic engineering analysis as necessary to ensure
that the DMS locations are selected based on optimum message delivery to the motorists.

33.9 Reference and Master ITS Design File

The CONSULTANT shall prepare the ITS design file to include all necessary design
elements and the reference files for topo, R/W roadway, utilities files, etc. This effort
includes the design and layout of proposed ITS devices, including but not limited to:
CCTV / Detection poles, DMS, detection devices, advanced traffic controllers, conduit,
cabinet-related pull boxes, service points, fiber optic sizing, and communications hubs. All
existing ITS infrastructure shall be referenced to the new ITS plan sheets (if applicable).

33.10 Reference and Master Communications Design File

The CONSULTANT shall prepare the communication design file to include all necessary
design elements and all associated reference files as well as reference files of topo, R/W,
roadway, utilities files, existing ITS communications infrastructure, etc. This effort includes
design and layout of proposed communications conduit, cabinet, pull boxes, splice boxes,
standard route markers, communications plan overview, fiber optic splicing, connections,
communications hubs, etc.

33.11 Pole Elevation Analysis

The CONSULTANT shall evaluate pole elevation requirements and design pole heights to
meet the Project requirements including field of view; elimination of occlusion; site access
for maintenance vehicles and personnel; access to pole mounted equipment, such as CCTV
cameras, traffic detectors, and cabinets; and probability of lightning strike.

33.12 Sign Panel Design Analysis

The CONSULTANT shall design all ITS signing in conjunction with the Roadway Master
Signing. This includes any static sign panel that includes changeable message elements.
Expressway and arterial full size DMS shall not be co-located with other static signs. [If
desired by the District].

33.13 Quantities

The CONSULTANT shall include all work required to determine the quantities for all items,
including ITS structures and devices, interconnect, and infrastructure (such as conduits, pull
boxes, splice boxes, fusion splices, splice enclosures, etc.). This work effort shall include
generating accurate quantities for computing the engineers estimate as required by the
District. Use digital submittal of plans as required by the DEPARTMENT.

33.14 Cost Estimate

The CONSULTANT shall prepare an engineers cost estimate for the project using historical
data from the FDOT or from other Industry sources. The CONSULTANT shall also load the
pay items and quantities into AASHTOWare Project Preconstruction for generating the
Summary of Pay Items and the FDOTs in-house estimates.

33.15 Technical Special Provisions

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-133
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall develop Technical Special Provisions (TSP) for the specific items
or conditions of the project that are not addressed in the FDOTS Standard Specifications,
Supplemental Specifications and Special Provisions.

33.16 Other ITS Analyses

[Add detailed project needs for any other ITS-related analyses here]

33.17 Field Reviews

The CONSULTANT shall conduct a field review for the required phase submittals. The
review shall identify necessary data for all elements of the project including, but not limited
to, the following:

Existing ITS Field Devices as compared with the latest FDOT standards and
District requirements
Device Make, Model, Capabilities, Condition / Age, Existence of SunGuide
Software Driver
Condition of Structure(s), cabinets, and other above-ground infrastructure and
devices
Type of Detection as Compared With Current District Standards
Underground Infrastructure
Proximity of other utilities
Traffic Operations
Any other field reconnaissance as necessary to develop a complete ITS design
package
33.18 Technical Meetings

The CONSULTANT shall attend meetings as necessary support the project.

33.19 Quality Assurance / Quality Control

The CONSULTANT shall be responsible for the professional quality, technical accuracy and
coordination of designs, drawings, specifications, and other services and work furnished by
the CONSULTANT under this contract.

The CONSULTANT shall provide a Quality Control Plan that describes the procedures to be
utilized to verify, independently check, and review all design drawings, specifications, and
other documentation prepared as a part of the contract. The CONSULTANT shall describe
how the checking and review processes are to be documented to verify that the required
procedures were followed. The Quality Control Plan may be one utilized by the
CONSULTANT as part of their normal operation or may be one specifically designed for
this project. The CONSULTANT shall utilize the Districts quality control checklist. The
responsible Professional Engineer that performed the Quality Control review shall sign a
statement certifying that the review was conducted.

The CONSULTANT shall, without additional compensation, correct all errors or


deficiencies in their works.

33.20 Supervision
33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS
A-134
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall provide all efforts required to supervise all technical design
activities.

33.21 Coordination

The CONSULTANT shall coordinate with Survey, Geotech, Drainage, Structures, Lighting,
Roadway Design, Utilities, municipalities, maintaining agencies and Traffic Operations to
produce a final set of construction contract documents and to ensure that a high degree of
accuracy for the design plans is achieved.

33 INTELLIGENT TRANSPORTATION SYSTEMS ANALYSIS


A-135
STAGE I FPID(S): 999999-1-52-01
[DATE]

34 INTELLIGENT TRANSPORTATION SYSTEMS PLANS

The CONSULTANT shall prepare a set of ITS Plans in accordance with the Plans
Preparation Manual that includes the following:

34.1 Key Sheet

The CONSULTANT shall prepare the key sheet in accordance with the latest format
depicted in the Plans Preparation Manual.

MUTCD

Standard Specs

Standard Index

34.2 Summary of Pay Items Including Designer Interface Quantity Input

The CONSULTANT shall include quantity input into Designer Interface and create the
CADD generated sheet.

34.3 Tabulation of Quantities

The CONSULTANT shall place pay item numbers, descriptions, quantities and grand totals
on the tabulation sheet(s) and provide updating of the tabulation of quantities sheets during
the design period.

34.4 General Notes / Pay Item Notes

The CONSULTANT shall include all pertinent general notes and pay item notes as deemed
fit and as established by the District.

34.5 Project Layout

The CONSULTANT shall prepare plan sheet(s) with an overview of the entire project that
include stations and offsets, project limits, intersection locations, devices, device
identification using SunGuide nomenclature, and plan sheet coverage.

34.6 Typical and Special Details

The CONSULTANT shall prepare typical and / or special details for conditions in the project
not addressed by the DEPARTMENTs Design Standards for Design, Construction,
Maintenance, and Utility Operations on the State Highway System. The CONSULTANT
shall prepare special details not addressed by FDOT Design Standards, including block
diagrams, hub cabinets, wiring diagrams, solar power service, and special mounting details.

34.7 Plan Sheet

The CONSULTANT shall prepare the ITS plan sheets utilizing the Design file to include all
necessary information related to the project design elements and all associated reference
34 INTELLIGENT TRANSPORTATION SYSTEM PLANS
A-136
STAGE I FPID(S): 999999-1-52-01
[DATE]

files. The plan sheets shall include general and pay item notes and pay items. The plans shall
depict the location of pull boxes, splice boxes, conduit runs and device locations with
setbacks from the travel way. Devices shall be located by station and offset.

34.8 ITS Communications Plans

The CONSULTANT shall prepare plans for the communications network. These plans shall
consist of block diagrams, splicing diagrams, port assignments, wiring diagrams, and all
other information necessary to convey the design concept to the contractor. These plans shall
be included in the ITS plan set and be prepared in a manner consistent with immediately
adjacent ITS project installations (planned or installed).

The communication system shall be an open-architecture, non-proprietary, real-time,


multimedia communications network. The communication system design must be
compatible and completely interoperable with the existing systems.

[Discuss any needs or allowance for temporary communication connectivity


options here].

The CONSULTANTs design shall include protecting and maintaining the existing ITS
infrastructure. For locations where existing ITS infrastructure is impacted, the
CONSULTANTs design shall include mitigation to minimize the downtime of existing
system as per the Districts requirements.

The CONSULTANT is responsible for the design of the communication infrastructure and
its integration with the DEPARTMENTs communication system. Additionally, the
CONSULTANT shall determine the most cost effective, best performing, communication
connectivity option. The communication system must allow command and control as well as
data and video transmission between the field devices and the TMCs at [insert location].

Conduit paths shall be selected to provide a continuous duct system on one side of the road
unless otherwise requested by the FDOT. The various components of ITS deployment will
be located on both sides of the freeway and therefore under pavement bore and lateral
conduits will be necessary to access equipment locations.

The CONSULTANT shall produce fiber optic cable splicing diagrams to show the
connectivity of the fiber optic cable from its termini at field devices to the TMC. The
diagrams shall denote new and existing fiber routes, splices, and terminations involved in
the work. The diagrams shall identify cables by size, tube color / number and stand colors /
numbers. All cables shall be identified either by numbering system identified either by
numbering system identified on the plans or by bounding devices. The diagrams shall denote
the types of connectors in the patch panels.

34.10 Grounding and Lightning Protection Plans

The CONSULTANT shall include efforts to design a complete and reliable lightning
protection design for each pole and associated devices, ITS device installation, as well as
device cabinets and communications hubs, etc. if not already addressed in the FDOTs
Design Standards for Design, Construction, Maintenance and Utility Operations on the State
Highway System.

34.11 Cross Sections

34 INTELLIGENT TRANSPORTATION SYSTEM PLANS


A-137
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT shall prepare cross sections for ITS devices.

34.12 Guide Sign Work Sheet(s)

The CONSULTANT shall prepare the guide sign work sheets to include all necessary
information related to the design of the static and dynamic message signs in the project
corridor.

34.13 Special Service Point Details

The CONSULTANT shall design any special service point and electrical distribution system
beyond the electric utility companys service point. The plan shall depict with pay items,
general and plan notes the locations of transformers, switches, disconnects, conduits, pull
boxes and power conductors. The plans shall identify the location of underground and
overhead service points with identifying pole and transformer numbers.

34.14 Strain Pole Schedule

The CONSULTANT shall incorporate the schedule detail chart for concrete or steel strain
poles in the plan set.

34.15 Overhead / Cantilever Sign Structure

For overhead truss and cantilever mounted devices, the CONSULTANT shall evaluate
pertinent data and information to develop the layout for locating and mounting devices to the
horizontal element of the structure, and coordinate the design of the structures with the
roadway and structural engineers.

The CONSULTANT shall be responsible for determining the overhead/cantilever structure


requirements for proper installation of the DMS, viewing angle and site distance
requirement as per Chapter 2e Guide Signs-Freeways and Expressways in the Manual on
Uniform Traffic Control Devices (MUTCD) and Florida Department of Transportation
(FDOT) Plans Preparation Manual and all other applicable manuals and guidelines as per
governing regulations.

34.16 Other Overhead Sign Structures (Long Span, Monotube, etc.)

For other overhead sign structures, the CONSULTANT shall evaluate pertinent data and
information to develop layout for locating and mounting device to the horizontal element of
the structure, and coordinate the design of the structures with the roadway and structural
engineers.

The CONSULTANT shall be responsible for determining the requirements for other type of
structures (long span, monotube, etc) used as part of the project for proper installation of the
DMS, viewing angle and site distance requirement as per Chapter 2e Guide Signs-
Freeways and Expressways in the Manual on Uniform Traffic Control Devices (MUTCD)
and Florida Department of Transportation (FDOT) Plans Preparation Manual and all other
applicable manuals and guidelines as per governing regulations.

34.17 Traffic Control Plans

The CONSULTANT shall prepare Traffic Control Plans (TCP) to minimize impact to traffic

34 INTELLIGENT TRANSPORTATION SYSTEM PLANS


A-138
STAGE I FPID(S): 999999-1-52-01
[DATE]

during the construction of ITS field devices and associated communications infrastructure
that will be deployed along the project corridor.

The TCP shall strive to maintain and sustain center-to-field device connectivity and
operability to the ITS field devices previously deployed along the project corridor. The TCP
effort shall consider and mitigate the impacts of the projects various construction phases so
as to sustain center-to-field devices connectivity and operability, maintaining operational
quality as a minimum at the level provided prior to construction start and minimizing down
time as much as possible. The CONSULTANT shall develop the TCP sheets for the project,
providing temporary communications as necessary, notes, details, and direction applicable to
the ITS elements and associated communications for inclusion in the TCP.

The CONSULTANT shall review the existing TMC Operations and develop additional
incident management service requirements as necessary to support during the Construction
Phase of the Project. The CONSULTANT shall coordinate with Districts Traffic Operations
ITS Office for additional information regarding existing Incident Management and TMC
Operational Procedures. [If desired by the District]

34.18 Interim Standards

The CONSULTANT shall adhere to all Departments Interim Standards for ITS applications.

34.19 GIS Data and Asset Management Requirements

The CONSULTANT is responsible for providing Geographic Information System (GIS),


spatial data, for the ITS components design. This information is required to integrate ITS
components to the SunGuide software. A coordinate point compatible with the Florida State
Plane System or FDOTs current coordinate plane system shall be collected for all ITS
components part of the Project design. All GIS information provided shall be compatible
with the FDOTs ITS FM asset management software.

The information shall be transferred to the as-built plans and submitted to the District in
electronic format along with the as-built plans.

The Global Positioning System (GPS) unit shall be provided by the CONSULTANT and
used to collect data with a minimum accuracy of three (3) meters when differentially
corrected. The CONSULTANT shall collect spatial data points and physical address
location for:

DMS location (mainline and arterial)


Vehicle detection pole location
CCTV camera pole location
Ground mounted cabinets
Fiber optic cable path (fiber backbone)
Communications hubs
Standard route markers
Lateral fiber optic cable connections
Lateral power cable connections
Pull boxes (power and fiber)
Splice boxes
Power drops (service point and cable path)
34 INTELLIGENT TRANSPORTATION SYSTEM PLANS
A-139
STAGE I FPID(S): 999999-1-52-01
[DATE]

34.20 Quality Assurance / Quality Control

The CONSULTANT shall utilize the Districts quality control checklist for traffic design
drawings in addition to the QC effort described in section three.

34.21 Supervision

The CONSULTANT shall supervise all technical design activities.

34 INTELLIGENT TRANSPORTATION SYSTEM PLANS


A-140
STAGE I FPID(S): 999999-1-52-01
[DATE]

35 GEOTECHNICAL

The CONSULTANT shall, for each project, be responsible for a complete geotechnical
investigation. All work performed by the CONSULTANT shall be in accordance with
DEPARTMENT standards, or as otherwise directed by the District Geotechnical Engineer.
The District Geotechnical Engineer will make interpretations and changes regarding
geotechnical standards, policies and procedures and provide guidance to the
CONSULTANT.

Before beginning each phase of investigation and after the Notice to Proceed is given, the
CONSULTANT shall submit an investigation plan for approval and meet with the
DEPARTMENTs Geotechnical Engineer or representative to review the project scope and
DEPARTMENT requirements. The investigation plan shall include, but not be limited to, the
proposed boring locations and depths, and all existing geotechnical information from
available sources to generally describe the surface and subsurface conditions of the project
site. Additional meetings may be required to plan any additional field efforts, review plans,
resolve plans/report comments, resolve responses to comments, and/or any other meetings
necessary to facilitate the project.

The CONSULTANT shall notify the DEPARTMENT in adequate time to schedule a


representative to attend all related meetings and field activities.

35.1 Document Collection and Review

CONSULTANT will review printed literature including topographic maps, county


agricultural maps, aerial photography (including historic photos), ground water resources,
geology bulletins, potentiometric maps, pile driving records, historic construction records
and other geotechnical related resources. Prior to field reconnaissance, CONSULTANT shall
review U.S.G.S., S.C.S. and potentiometric maps, and identify areas with problematic soil
and groundwater conditions.

Roadway

The CONSULTANT shall be responsible for coordination of all geotechnical related field
work activities. The CONSULTANT shall retain all samples until acceptance of Phase IV
plans. Rock cores shall be retained as directed in writing by the District Geotechnical
Engineer.

Obtain pavement cores as directed in writing by the District Geotechnical Engineer.

If required by the District Geotechnical Engineer, a preliminary roadway exploration shall


be performed before the Phase I plans submittal. The preliminary roadway exploration will
be performed and results provided to the Engineer of Record to assist in setting roadway
grades and locating potential problem areas. The preliminary roadway exploration shall be
performed as directed in writing by the District Geotechnical Engineer.

CONSULTANT shall perform specialized field-testing as required by project needs and as


directed in writing by the District Geotechnical Engineer.

35 GEOTECHNICAL
A-141
STAGE I FPID(S): 999999-1-52-01
[DATE]

All laboratory testing and classification will be performed in accordance with applicable
DEPARTMENT standards, ASTM Standards or AASHTO Standards, unless otherwise
specified in the Contract Documents.

35.2 Develop Detailed Boring Location Plan

Develop a detailed boring location plan. Meet with DEPARTMENT Geotechnical Project
Manager for boring plan approval. If the drilling program expects to encounter artesian
conditions, the CONSULTANT shall submit a methodology(s) for plugging the borehole to
the DEPARTMENT for approval prior to commencing with the boring program.

35.3 Stake Borings/Utility Clearance

Stake borings and obtain utility clearance.

35.4 Muck Probing

Probe standing water and surficial muck in a detailed pattern sufficient for determining
removal limits to be shown in the Plans.

35.5 Coordinate and Develop MOT Plans for Field Investigation

Coordinate and develop Maintenance of Traffic (MOT) plan. All work zone traffic control
will be performed in accordance with the DEPARTMENTs Roadway and Traffic Design
Standards Index 600 series.

35.6 Drilling Access Permits

Obtain all State, County, City, and Water Management District permits for performing
geotechnical borings, as needed.

35.7 Property Clearances

Notify property tenants in person of drilling and field activities, if applicable. Written
notification to property owners/tenants is the responsibility of the DEPARTMENTs Project
Manager.

35.8 Groundwater Monitoring

Monitor groundwater, using piezometers.

35.9 LBR / Resilient Modulus Sampling

Collect appropriate samples for Limerock Bearing Ratio (LBR) testing. Deliver Resilient
Modulus samples to the District Materials Office or the State Materials Office in
Gainesville, as directed by the DEPARTMENT.

35.10 Coordination of Field Work

Coordinate all field work required to provide geotechnical data for the project.

35.11 Soil and Rock Classification - Roadway


35 GEOTECHNICAL
A-142
STAGE I FPID(S): 999999-1-52-01
[DATE]

Refine soil profiles recorded in the field, based on results of laboratory testing.

35.12 Design LBR

Determine design LBR values from the 90% and mean methods when LBR testing is
required by the DEPARTMENT.

35.13 Laboratory Data

Tabulate laboratory test results for inclusion in the geotechnical report, the report of tests
sheet (Roadway Soil Survey Sheet), and for any necessary calculations and analyses.

35.14 Seasonal High Water Table

Review the encountered ground water levels and estimate seasonal high ground water levels.
Estimate seasonal low ground water levels, if requested.

35.15 Parameters for Water Retention Areas

Calculate parameters for water retention areas, exfiltration trenches, and/or swales.

35.16 Delineate Limits of Unsuitable Material

Delineate limits of unsuitable material(s) in both horizontal and vertical directions. Assist
the Engineer of Record with detailing these limits on the cross-sections. If requested,
prepare a plan view of the limits of unsuitable material.

35.17 Electronic Files for Cross-Sections

Create electronic files of boring data for cross-sections.

35.18 Embankment Settlement and Stability

Estimate the total magnitude and time rate of embankment settlements. Calculate the factor
of safety against slope stability failure.

35.19 Monitor Existing Structures

Provide Roadway EOR guidance on the radius to review existing structures for monitoring.

Optional services (may be negotiated at a later date if needed): Identify existing structures in
need of settlement, vibration and/or groundwater monitoring by the contractor during
construction and coordinate with the EOR and structural engineer (when applicable) to
develop mitigation strategies. When there is risk of damage to the structure or facility,
provide recommendations in the geotechnical report addressing project specific needs and
coordinate those locations with the EOR. See PPM Volume I Chapter 34 and Chapter 9 of
the Soils and Foundations Handbook.

35.20 Stormwater Volume Recovery and/or Background Seepage Analysis

Perform stormwater volume recovery analysis as directed by the DEPARTMENT.

35 GEOTECHNICAL
A-143
STAGE I FPID(S): 999999-1-52-01
[DATE]

35.21 Geotechnical Recommendations

Provide geotechnical recommendations regarding the proposed roadway construction project


including the following: description of the site/alignment, design recommendations and
discussion of any special considerations (i.e. removal of unsuitable material, consolidation
of weak soils, estimated settlement time/amount, groundwater control, high groundwater
conditions relative to pavement base, etc.) Evaluate and recommend types of geosynthetics
and properties for various applications, as required.

35.22 Pavement Condition Survey and Pavement Evaluation Report

If a pavement evaluation is performed, submit the report in accordance with Section 3.2 of
the Materials Manual: Flexible Pavement Coring and Evaluation. Enter all core information
into the Pavement Coring and Reporting (PCR) system.

35.23 Preliminary Roadway Report

If a preliminary roadway investigation is performed, submit a preliminary roadway report


before the Phase I plans submittal. The purpose of the preliminary roadway report will be to
assist in setting road grades and locating potential problems.

Copies of U.S.G.S. and S.C.S. maps with project limits shown.


A report of tests sheet that summarizes the laboratory test results, the soil
stratification (i.e. soils grouped into layers of similar materials) and construction
recommendations relative to Standard Indices 500 and 505.
The results of all tasks discussed in all previous sections regarding data
interpretation and analysis.
An appendix that contains stratified soil boring profiles, laboratory test data
sheets, sample embankment settlement and stability calculations, design LBR
calculation/graphs, and other pertinent calculations.
The CONSULTANT will respond in writing to any changes and/or comments
from the DEPARTMENT and submit any responses and revised reports.
35.24 Final Report

The Final Roadway Report shall include the following:

Copies of U.S.G.S. and S.C.S. maps with project limits shown.


A report of tests sheet that summarizes the laboratory test results, the soil
stratification (i.e. soils grouped into layers of similar materials) and construction
recommendations relative to Standard Indices 500 and 505.
The results of all tasks discussed in all previous sections regarding data
interpretation and analysis.
An appendix that contains stratified soil boring profiles, laboratory test data
sheets, sample embankment settlement and stability calculations, design LBR
calculation/graphs, and other pertinent calculations.
The CONSULTANT will respond in writing to any changes and/or comments
from the DEPARTMENT and submit any responses and revised reports.
35.25 Auger Boring Drafting

35 GEOTECHNICAL
A-144
STAGE I FPID(S): 999999-1-52-01
[DATE]

Draft auger borings as directed by the DEPARTMENT.

35.26 SPT Boring Drafting

Draft SPT borings as directed by the DEPARTMENT.

Structures

The CONSULTANT shall be responsible for coordination of all geotechnical related


fieldwork activities. The CONSULTANT shall retain all samples until acceptance of
Phase IV plans. Rock cores shall be retained as directed in writing by the District
Geotechnical Engineer.

CONSULTANT shall perform specialized field-testing as required by needs of project and as


directed in writing by the District Geotechnical Engineer.

All laboratory testing and classification will be performed in accordance with applicable
DEPARTMENT standards, ASTM Standards or AASHTO Standards, unless otherwise
specified in the Contract Documents.

The staff hour tasks for high embankment fills and structural foundations for bridges, box
culverts, walls, high-mast lighting, overhead signs, mast arm signals, strain poles, buildings,
and other structures include the following:

35.27 Develop Detailed Boring Location Plan

Develop a detailed boring location plan. Meet with DEPARTMENT Geotechnical Project
Manager for boring plan approval. If the drilling program expects to encounter artesian
conditions, the CONSULTANT shall submit a methodology(s) for plugging the borehole to
the DEPARTMENT for approval prior to commencing with the boring program.

35.28 Stake Borings/Utility Clearance

Stake borings and obtain utility clearance.

35.29 Coordinate and Develop MOT Plans for Field Investigation

Coordinate and develop MOT plan. All work zone traffic control will be performed in
accordance with the DEPARTMENTs Roadway and Traffic Design Standards Index 600
series.

35.30 Drilling Access Permits

Obtain all State, County, City, and Water Management District permits for performing
geotechnical borings, as needed.

35.31 Property Clearances

Notify property tenants in person of drilling and field activities, if applicable. Written
notification to property owners/tenants is the responsibility of the DEPARTMENTs Project
Manager.

35 GEOTECHNICAL
A-145
STAGE I FPID(S): 999999-1-52-01
[DATE]

35.32 Collection of Corrosion Samples

Collect corrosion samples for determination of environmental classifications.

35.33 Coordination of Field Work

Coordinate all field work required to provide geotechnical data for the project.

35.34 Soil and Rock Classification - Structures

Soil profiles recorded in the field should be refined based on the results of laboratory testing.

35.35 Tabulation of Laboratory Data

Laboratory test results should be tabulated for inclusion in the geotechnical report and for
the necessary calculations and analyses.

35.36 Estimate Design Groundwater Level for Structures

Review encountered groundwater levels, estimate seasonal high groundwater levels, and
evaluate groundwater levels for structure design.

35.37 Selection of Foundation Alternatives (BDR)

Evaluation and selection of foundation alternative, including the following:

GRS-IBS
Spread footings
Prestressed concrete piling - various sizes
Steel H- piles
Steel pipe piles
Drilled shafts
Foundation analyses shall be performed using approved DEPARTMENT
methods. Assist in selection of the most economical, feasible foundation
alternative.
35.38 Detailed Analysis of Selected Foundation Alternate(s)

Detailed analysis and basis for the selected foundation alternative. Foundation analyses shall
be performed using approved DEPARTMENT methods and shall include:

GRS-IBS (including the parameters identified in the Instructions for


Developmental Design Standard D6025 to be provided by the Geotechnical
Engineer)
Spread footings (including soil bearing capacity, minimum footing width, and
minimum embedment depth).
For pile and drilled shaft foundations, provide graphs of ultimate axial soil
resistance versus tip elevations. Calculate scour resistance and/or downdrag
(negative skin friction), if applicable.
CONSULTANT shall assist the Engineer of Record in preparing the Pile Data
35 GEOTECHNICAL
A-146
STAGE I FPID(S): 999999-1-52-01
[DATE]

Table (including test pile lengths, scour resistance, downdrag, minimum tip
elevation, etc.)
Provide the design soil profile(s), which include the soil model/type of each
layer and all soil-engineering properties required for the Engineer of Record to
run the FBPier computer program. Review lateral analysis of selected
foundation for geotechnical compatibility.
Estimated maximum driving resistance anticipated for pile foundations.
Provide settlement analysis.
35.39 Bridge Construction and Testing Recommendations

Provide construction and testing recommendations including potential constructability


problems.

35.40 Lateral Load Analysis (Optional)

Perform lateral load analyses as directed by the DEPARTMENT.

35.41 Walls

Provide the design soil profile(s), which include the soil model/type of each layer and all soil
engineering properties required by the Engineer of Record for conventional wall analyses
and recommendations. Review wall design for geotechnical compatibility and
constructability.

Evaluate the external stability of conventional retaining walls and retained earth wall
systems. For retained earth wall systems, calculate and provide minimum soil reinforcement
lengths versus wall heights, and soil parameters assumed in analysis. Estimate differential
and total (long term and short term) settlements.

Provide wall construction recommendations.

35.42 Sheet Pile Wall Analysis (Optional)

Analyze sheet pile walls as directed by the DEPARTMENT.

35.43 Design Soil Parameters for Signs, Signals, High Mast Lights, and Strain Poles
and Geotechnical Recommendations

Provide the design soil profile(s) that include the soil model/type of each layer
and all soil properties required by the Engineer of Record for foundation design.
Review design for geotechnical compatibility and constructability.
35.44 Box Culvert Analysis

Provide the design soil profile(s) that include the soil model/type of each layer
and all soil properties required by the Engineer of Record for foundation design.
Review design for geotechnical compatibility and constructability.
Provide lateral earth pressure coefficients.
Provide box culvert construction and design recommendations.

35 GEOTECHNICAL
A-147
STAGE I FPID(S): 999999-1-52-01
[DATE]

Estimate differential and total (long term and short term) settlements.
Evaluate wingwall stability.
35.45 Preliminary Report - BDR

The preliminary structures report shall contain the following discussions as appropriate for
the assigned project:

Copies of U.S.G.S. and S.C.S. maps with project limits shown.


Summary of structure background data, S.C.S., U.S.G.S., geologic and
potentiometric data.
The results of all tasks discussed in all previous sections regarding data
interpretation and analysis).
Recommendations for foundation installation, or other site preparation soils-
related construction considerations with plan sheets as necessary.
Any special provisions required for construction that are not addressed in the
DEPARTMENTs Standard specification.
An Appendix which includes SPT and CPT boring/sounding profiles, data from
any specialized field tests, engineering analysis, notes/sample calculations,
sheets showing ultimate bearing capacity curves versus elevation for piles and
drilled shafts, a complete FHWA check list, pile driving records (if available),
and any other pertinent information.
35.46 Final Report - Bridge and Associated Walls

The final structures report shall include the following:

Copies of U.S.G.S. and S.C.S. maps with project limits shown.


Summary of structure background data, S.C.S., U.S.G.S., geologic and
potentiometric data.
The results of all tasks discussed in all previous sections regarding data
interpretation and analysis.
Recommendations for foundation installation, or other site preparation soils-
related construction considerations with plan sheets as necessary.
Any special provisions required for construction that are not addressed in the
DEPARTMENTs Standard specification.
An Appendix which includes SPT and CPT boring/sounding profiles, data from
any specialized field tests, engineering analysis, notes/sample calculations,
sheets showing ultimate bearing capacity curves versus elevation for piles and
drilled shafts, a complete FHWA check list, pile driving records (if available),
and any other pertinent information.
35.47 Final Reports - Signs, Signals, Box Culvert, Walls, and High Mast Lights

The final reports shall include the following:

Copies of U.S.G.S. and S.C.S. maps with project limits shown.


Summary of structure background data, S.C.S., U.S.G.S., geologic and
potentiometric data.

35 GEOTECHNICAL
A-148
STAGE I FPID(S): 999999-1-52-01
[DATE]

The results of all tasks discussed in all previous sections regarding data
interpretation and analysis).
Recommendations for foundation installation, or other site preparation soils-
related construction considerations with plan sheets as necessary.
Any special provisions required for construction that are not addressed in the
DEPARTMENTs Standard specification.
An Appendix which includes SPT and CPT boring/sounding profiles, data from
any specialized field tests, engineering analysis, notes/sample calculations,
sheets showing ultimate bearing capacity curves versus elevation for piles and
drilled shafts, a complete FHWA check list, pile driving records (if available),
and any other pertinent information.
Final reports will incorporate comments from the DEPARTMENT and contain any
additional field or laboratory test results, recommended foundation alternatives along with
design parameters and special provisions for the contract plans. These reports will be
submitted to the District Geotechnical Engineer for review prior to project completion. After
review by the District Geotechnical Engineer, the reports will be submitted to the District
Geotechnical Engineer in final form and will include the following:

All original plan sheets (11 x 17)


One set of all plan and specification documents, in electronic format, according
to DEPARTMENT requirements
Two sets of record prints
Six sets of any special provisions
All reference and support documentation used in preparation of contract plans
package
Additional final reports (up to four), aside from stated above, may be needed and requested
for the DEPARTMENTs Project Manager and other disciplines.

The final reports, special provisions, as well as record prints, will be signed and sealed by a
Professional Engineer licensed in the State of Florida.

Draft the detailed boring/sounding standard sheet, including environmental classification,


results of laboratory testing, and specialized construction requirements, for inclusion in final
plans.

35.48 SPT Boring Drafting

Prepare a complete set of drawings to include all SPT borings, auger borings and other
pertinent soils information in the plans. Include these drawings in the Final Geotechnical
Report. Draft borings, location map, S.C.S. map and U.S.D.A. map as directed by the
DEPARTMENT. Soil symbols must be consistent with those presented in the latest Florida
Department of Transportation Soils and Foundations Handbook.

35.49 Other Geotechnical

Other geotechnical effort specifically required for the project as determined by the
Department, and included in the geotechnical upset limit.

35.50 Technical Special Provisions

35 GEOTECHNICAL
A-149
STAGE I FPID(S): 999999-1-52-01
[DATE]

35.51 Field Reviews

Identify and note surface soil and rock conditions, surface water conditions and locations,
and preliminary utility conflicts. Observe and note nearby structures and foundation types.

35.52 Technical Meetings

35.53 Quality Assurance/Quality Control

35.54 Supervision

35.55 Coordination

35 GEOTECHNICAL
A-150
STAGE I FPID(S): 999999-1-52-01
[DATE]

36 3D MODELING

The CONSULTANT shall analyze and document Roadway Tasks in accordance with all applicable
manuals, guidelines, standards, handbooks, procedures, and current design memorandums.

The CONSULTANT shall deliver all master design files, 3D surface design models, and all supporting
digital files for the development of plans as required in the DEPARTMENTs CADD Manual.

The CONSULTANT shall prepare a 3D model using the latest FDOT software in accordance with the
FDOT CADD Manual. Includes all efforts required for developing files for 3D deliverables supporting
automated machine guidance for design models. This includes importing survey data and creation of
existing 3D surface features and models, and developing proposed corridor models with necessary detail
of features to depict the proposed project in 3D to comply with the DEPARTMENT CADD Manual.

The CONSULTANT shall add detail to the corridor and design model for 3D design. Includes many
elements that contribute to this including but not limited to slope transitions, typical section transitions,
changes in pavement depth, berms, swales/ditches, and other feature transitions. Extra corridor structure
leads to extra assemblies, extra targeting, etc. Dynamic relationships must be maintained. Frequency must
be increase to achieve a useable model.

The CONSULTANT shall create an accurate roadway design model which includes modeling the
intersections.

The CONSULTANT shall provide sufficient detail in the 3D model to account for driveways, Guardrail
Terminal Locations, etc. and other graded areas where surface triangles are delivered as break lines.

36.1 Phase I 3D Design Model (30% Plans)

The CONSULTANT shall prepare, submit and present for approval by the DEPARTMENT, 30%
complete 3D interactive model, comprised of, but not limited to: Existing features (pavement, shoulders,
sidewalk, curb/gutter, utilities-if required per scope, drainage - if required per scope) and proposed
corridor(s).

36.2 Phase II 3D Design Model (60% Plans)

The CONSULTANT shall prepare, submit and present for approval by the DEPARTMENT, 60%
complete 3D model, comprised of, but not limited to: Modification of 30% model to update the model to
comply with changes based on 30% review comments and to include the addition of ponds, floodplain
compensation sites, retaining walls, barrier walls, guardrail terminals, cross overs, gore areas, side street
connections, roundabouts, and driveways.

[List optional services to be included, i.e. Curb Ramps, Closed Drainage Network, Bridge Modeling,
Bridge Abutment, Overhead sign post/structures with foundation, Toll gantry and overhead DMS
structures with foundation, proposed utilities (pressure pipe/gravity), etc.].

36.3 Phase III 3D Design Model (90% Plans)

The CONSULTANT shall prepare, submit and present for approval by the DEPARTMENT, 90%
complete 3D model, comprised of, but not limited to: Modification of 60% model to update the model to
comply with changes based on 60% review comments and to further refine areas of transition between

36 PROJECT REQUIREMENTS
A-151
STAGE I FPID(S): 999999-1-52-01
[DATE]

templates, detailed grading areas, bridge approaches and end bents, median noses, shoulder transition
areas, retaining walls, barrier walls and guardrail.

36.4 Final 3D Model Design (100% Plans)

The CONSULTANT shall prepare for approval by DEPARTMENT, 100% complete 3D model, comprised
of, but not limited to: Modification of 90% model to update the model to comply with changes based on
90% review comments and to accurately generate, export and otherwise prepare the final 3D deliverable
files as described in the DEPARTMENTs CADD Manual.

36.5 Cross Section Design Files

The CONSULTANT shall establish and develop cross section design files in accordance with the
DEPARTMENTs CADD manual and Plans Preparation Manual. Includes all work required to
establish and utilize intelligent/automated methods for creating cross sections including
determining the locations for which all cross sections will be shown, existing and proposed
features, cross section refinement, placement of utilities and drainage, soil boxes, R/W lines,
earthwork calculations, and other required labeling.

36.6 Template and Assembly Development (Optional)

The CONSULTANT shall prepare for approval by DEPARTMENT, specialty templates or assemblies
needed to develop the features required to deliver the 3D model.

36.7 Quality Assurance/Quality Control

36.8 Supervision

36.9 Coordination

36 PROJECT REQUIREMENTS
A-152
STAGE I FPID(S): 999999-1-52-01
[DATE]

37 PROJECT REQUIREMENTS

37.1 Liaison Office

The DEPARTMENT and the CONSULTANT will designate a Liaison Office and a Project
Manager who shall be the representative of their respective organizations for the Project.
While it is expected the CONSULTANT shall seek and receive advice from various state,
regional, and local agencies, the final direction on all matters of this project remain with the
DEPARTMENT Project Manager.

37.2 Key Personnel

The CONSULTANTs work shall be performed and directed by the key personnel identified
in the proposal presentations by the CONSULTANT. Any changes in the indicated personnel
shall be subject to review and approval by DEPARTMENT.

37.3 Progress Reporting

The CONSULTANT shall meet with the DEPARTMENT as required and shall provide a
written monthly progress report with approved schedule, schedule status, and payout curve
or by using the earned value method that describe the work performed on each task. The
report will include assessing project risk through monthly documentation of identifying and
updating the risk category and approach for monitoring those tasks. Invoices shall be
submitted after the DEPARTMENT approves the monthly progress report and the payout
curve or with earned value analysis. The Project Manager will make judgment on whether
work of sufficient quality and quantity has been accomplished by comparing the reported
percent complete against actual work accomplished.

37.4 Correspondence

Copies of all written correspondence between the CONSULTANT and any party pertaining
specifically to this contract shall be provided to the DEPARTMENT for their records within
one (1) week of the receipt or mailing of said correspondence.

37.5 Professional Endorsement

The CONSULTANT shall have a Licensed Professional Engineer in the State of Florida sign
and seal all reports, documents, technical special provisions, and plans as required by
DEPARTMENT standards.

37.6 Computer Automation

The project will be developed utilizing Computer Aided Drafting and Design (CADD)
systems. The DEPARTMENT makes available software to help assure quality and
conformance with policy and procedures regarding CADD. It is the responsibility of the
CONSULTANT to meet the requirements in the DEPARTMENTs CADD Manual. The
CONSULTANT shall submit final documents and files as described therein.

37.7 Coordination with Other Consultants

36 PROJECT REQUIREMENTS
A-153
STAGE I FPID(S): 999999-1-52-01
[DATE]

The CONSULTANT is to coordinate his work with any and all adjacent and integral
consultants so as to effect complete and homogenous plans and specifications for the
project(s) described herein.

37.8 Optional Services

At the DEPARTMENTs option, the CONSULTANT may be requested to provide optional


services. The fee for these services shall be negotiated in accordance with the terms detailed
in Exhibit B, Method of Compensation, for a fair, competitive and reasonable cost,
considering the scope and complexity of the project(s). Additional services may be
authorized by Letter of Authorization or supplemental amendment in accordance with
paragraph 2.00 of the Standard Consultant Agreement. The additional services may include
Construction Assistance, Review of Shop Drawings, Final Bridge Load Rating, update
(Category II) bridge plans electronically (CADD) for the Final "As-Built" conditions, based
on documents provided by the DEPARTMENT (CADD Services Only) or other Services as
required.

36 PROJECT REQUIREMENTS
A-154
STAGE I FPID(S): 999999-1-52-01
[DATE]

38 INVOICING LIMITS

Payment for the work accomplished shall be in accordance with Method of Compensation of
this contract. Invoices shall be submitted to the DEPARTMENT, in a format prescribed by
the DEPARTMENT. The DEPARTMENT Project Manager and the CONSULTANT shall
monitor the cumulative invoiced billings to ensure the reasonableness of the billings
compared to the project schedule and the work accomplished and accepted by the
DEPARTMENT.

The CONSULTANT shall provide a list of key events and the associated total percentage of
work considered to be complete at each event. This list shall be used to control invoicing.
Payments will not be made that exceed the percentage of work for any event until those
events have actually occurred and the results are acceptable to the DEPARTMENT.

37 INVOICING LIMITS