00 NO. DRG-Model
00 NO. DRG-Model
00 NO. DRG-Model
SHEAR
STIRRUPS
U TYPE BARS U TYPE BAR
Ldt = DEVELOPMENT LENGTH
IN TENSION TYPICAL DETAIL OF HOOKS DETAIL OF STIRRUPS IN COLUMN CORE REGION COLUMN TIES
A
FIXING TIES TO BE
SPECIAL CONFINING
DOWELS
THE CROSS SECTIONAL AREA OF
COLUMN FACE THE DOWELS MUST BE SAME AS THE
BAR OF THE UPPER COLUMN
0
SPLICING WITH THE LOWER BARS CRANKED IN TO A SPLICING WHEN THE LOWER BARS CRANKED IN TO A
POSITION INSIDE THE UPPER BARS WHEN THE RELATIVE POSITION INSIDE THE UPPER BARS WITH STEPPING OF
SPLICING AT THE FLOOR LEVEL WHEN THE RELATIVE
DISPLACEMENT OF COLUMN FACES IS LESS THAN 75MM. COLUMN ON ONE SIDE
DISPLACEMENT OF COLUMN FACES IS MORE THAN 75 MM.
1 1 2
MINIMUM TWO BARS BARS TO HAVE THE REQUIRED
1 1 2
100% 60% 25% 60% 100% 100% 60% 20% ANCHORAGE VALUE ON
BOTH SIDES
0.5 Ast Ast
1 2
SIMPLIFIED CURTAILMENT RULES FOR SIMPLY SUPPORTED BEAM
END SUPPORT INTERMEDIATE SUPPORT
(RESTAINED) * 0.15 L1 SHOULD NOT BE LESS THAN Ldt
SIMPLIFIED CURTAILMENT RULES FOR A CANTILEVER BEAM
SIMPLIFIED CURTAILMENT RULES FOR CONTINUOUS BEAM PROJECTING FROM A BEAM OVER A COLUMN