8 7 6 5 4 3 2 1

CANOPY WIDTH
(SEE NOTES)
COLUMN F
F

GUTTER
DEFLECTOR PLATE

BEAM

CONCRETE FOOTING
CANOPY HEIGHT - FOOTING SIZE AS
(SEE NOTES) REQUIRED FOR BEARING E
E UPLIFT AND MOMENT
(BY OTHERS)

ALUMINUM RIVET
-10 PER CORNER SET,
6 PER OUTSIDE, 9 INCH #5 REBAR
COLUMN 4 PER INSIDE
B #12 x 1" SS SCREW
-USED FOR INSTALLATION STYROFOAM BLOCKOUT
OF CANOPY DECKING -REMOVED AND FILLED WITH
1/4-20 x 1-1/2" SS SCREW CONCRETE DURING CANOPY
USED FOR CANOPY INSTALLATION
FRAMING CONNECTIONS

EXTRUDED DETAIL B
D BEAM BRACKET SCALE 1 : 6 D

COLUMN
DEFLECTOR PLATE
WELDED -SEAL TO INTERIOR
END CAP OF COLUMN

BEAM ALUMINUM

SECTION VIEW OF CANOPY 6" RIVET


1/4-20 x 1-1/2" SS SCREW CONCRETE SLAB
USED FOR CANOPY (BY OTHERS)
FRAMING CONNECTIONS
3
4" 24"
C
C
WELDED
COLUMN
BRACKET
COLUMN 9 INCH #5 REBAR
DETAIL A
SCALE 1 : 4 STYROFOAM BLOCKOUT
-REMOVED AND FILLED WITH
CONCRETE DURING CANOPY
CONCRETE FOOTING INSTALLATION
- FOOTING SIZE AS
REQUIRED FOR BEARING
UPLIFT AND MOMENT
(BY OTHERS)

B
B

DETAIL B SIDE VIEW


SPECIFICATIONS SCALE 1 : 7
Section 107300 - Aluminum Walkway Covers

1.01 General Description of Work:


A. Work in this section shall include design and fabrication of pre-engineered aluminum canopies.
B. Canopies are to be fabricated and installed according to approved shop drawings.

1.02 Design Criteria: JOB NAME:


A. International Building Code 2015
B. ASCE 7-10
C. Aluminum Design Manual 2015 Aluminum
D. Local governing codes and standards for site location Walkway
1.03 Materials:
Covers
A. All materials shall be extruded from aluminum unless indicated otherwise on the drawing. NOTES:
A B. Material sizes shall meet or exceed the design criteria on 1.02 • DC = DRAINING COLUMN (IF APPLICABLE) A

1.04 Finishes: • CANOPY WIDTH RECOMMENDED NOT TO TITLE:

A. Factory applied baked enamel to comply with AAMA 2603 EXCEED 13'-0" SHORTWAYS
B. Color selected from manufacturers standard colors • COLUMN HEIGHT RECOMMENDED NOT TO WITH BEAMS
EXCEED 12'-0" OR WIDTH OF CANOPY, WHICH

ISOMETRIC VIEW OF CANOPY


1.05 Manufacturers:
EVER IS LOWER
A. Mitchell Metals, LLC -www.mitchellmetals.net - 770-431-7300 REVISION # :
B. Dittmer - www.dittdeck.com - 407-699-1755 • ALL FASTENERS TO BE 300 SERIES STAINLESS STEEL
C. See Specifications 2.1-C for conditions of equivalent systems by other manufacturers. OR ALUMINUM STAMP DATE: 9/13/2017 SHEET 1 OF 1