Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SD 005 SD 005

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DESCRIPTION

REV DATE REMARKS


0 8-11-2021 ISSUED FOR ADVANCED
INFORMATON

BEAM & SLAB

LAP LENGTH CONCRETE GRADE OF SLAB AS SHOWN ON DRAWINGS


90 ROOF LEVEL
BEAM & SLAB

SLAB REINF.
LINKS **

COLUMN / WALL COLUMN / WALL


LINKS

COLUMN REINF.
REFER TO SCHEDULE
COLUMN / WALL
CASE 1 CASE 2
LAP LENGTH

1ST LINK
LINKS *
75

TYPICAL STOREY
LEVEL
TYPICAL BEAM/COLUMN INTERSECTION IF
COLUMN CONCRETE GRADE < 1.4 BEAM/SLAB CONCRETE GRADE
LINKS **

A
LINKS

COLUMN REINF. SLAB / BEAM / COL/ WALL


SLAB / BEAM CONCRETE
REFER TO SCHEDULE - CONCRETE GRADE AS FOR
BEAM & SLAB COLUMN
2 ADDITIONAL SETS OF
LAP LENGTH

1ST LINK LINKS AT 75 C/C


LINKS *

CENTERED ON CRANK
75

2ND STOREY TYPICAL


LEVEL

BEAM & SLAB


LINKS **

COLUMN / WALL COLUMN / WALL


LINKS

COLUMN REINF.
REFER TO SCHEDULE
COLUMN / WALL CONCRETE
CASE 1 CASE 2
LAP LENGTH

1ST LINK
LINKS *

NOTES:
75

1ST STOREY
LEVEL 1. THIS DETAILS IS APPLICABLE WHERE RATIO OF
TYPICAL BEAM/COLUMN INTERSECTION IF CONCRETE GRADE OF RC COLUMN, WALL /SLAB, BEAM SECTION A
IS I.4 OR MORE. NTS -
COLUMN CONCRETE GRADE > 1.4 BEAM/SLAB CONCRETE GRADE 2. CONCRETE IN HATCHED AREA TO BE CAST FIRST
LINKS **

BEFORE PROCEEDING TO CAST REST OF SLAB / BEAM.


LEGEND: REST OF THE AREA TO BE CAST WHERE CONCRETE IN
HATCHED AREA IS STILL PLASTIC. TYPICAL INTERNAL COLUMN / WALL
- COLUMN CONCRETE GRADE
(FOR EDGE AND CORNER COLUMN / WALL DETAIL SIMILAR)
LINKS

COLUMN REINF.
REFER TO SCHEDULE
- BEAM/SLAB CONCRETE GRADE
LAP LENGTH

1ST LINK
LINKS *
75

BASEMENT
LEVEL/COLUMN STUMP
SD18 : BEAM / COLUMN INTERSECTION DETAILS
450
MIN
PILECAP H10-100 OVER
COLUMN WIDTH
900 600

3 SETS LINKS AT EQUAL SPACING

300
H10-150

COLUMN/WALL H10-100 OVER


LAP LENGTH
CONCRETE GRADE COLUMN WIDTH
UNBUNDLED BARS

C60 ~ C90 REFER TO SD-02 400 BEAM

NOTE:
1. LAPPING LENGTHS AND DETAILS ARE ALSO APPLICABLE TO WALL REINFORCEMENT.

MIX DEVELOPMENT AT 8 SHENTON WAY


CASE 1 CASE 1
TYPICAL COLUMN DETAILS H16-100 OVER
COLUMN WIDTH
(TYPICAL WALL REINFORCEMENT DETAILS 1100 600
(2H16 MIN.)

SIMILAR)
X

* DENOTES SPACING OF LINK @ LAP:


400
H10-150

< = 12 DIA OF LONGITUDINAL BAR &


< = 0.6 LESSER DIMENSION OF COLUMN H16-150 OVER
< = 240mm COLUMN WIDTH
AT LEAST 3 LINKS COLUMN/WALL
X

** DENOTES LARGER DIMENSION OF COLUMN 400 BEAM


REQUIREMENT FOR SPACING OF LINK:
< = 12 DIA OF LONGITUDINAL BAR &
< = 0.6 LESSER DIMENSION OF COLUMN
< = 240mm
AT LEAST 3 LINKS CASE 2

CASE 2 TYPICAL DETAIL FOR BEAM PROJECTING

STANDARD DETAILS (SHEET 4)


BEYOND SUPPORTING COLUMN/WALL
TYPICAL DETAIL AT COLUMN SPLICE
X DENOTES LAP LENGTH ( lo)

SD16 SD17 : TYPICAL COLUMN SPLICE SD15

DATE
8 NOVEMBER 2021

JOB NO. SIZE AO


8 NOVEMBER 2021 208048-01
FOR ADVANCED INFORMATION REV 0
SHEET NO.
S-SD-005