General Specifi Cations: Fieldmate
General Specifi Cations: Fieldmate
General Specifi Cations: Fieldmate
1. Features
FieldMate is a PC based configuration tool that
performs numerous tasks, including initial setup, daily
maintenance, troubleshooting, and configuration
backup for device replacement. These tasks are
streamlined by FieldMates intuitive operation and
integrated environment, which is independent from
communication protocols and device vendors.
F001.ai
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
<<Contents>> <<Index>> 3
n User management * The I/O configuration data can be exported/imported between
Provides simple security and activity logging by FieldMate Validator and CENTUM VP/ProSafe-RS. For that,
the following software is required to be installed in CENTUM
allowing users to be defined by a user name and VP/ProSafe-RS system.
password. The user ID is incorporated as part of the CENTUM VP:
device maintenance history. - VP6E5000 Engineering Server Function
- VP6E5100 Standard Engineering Function
- VP6E5210 Module-based Engineering Package
n 3rd Party COMM DTM support ProSafe-RS:
Provides advanced connections and communication - RS4E5000 Engineering Server Function
networking enabling: - RS4E5100 Safety System Engineering and Maintenance Function
- Access PROFIBUS-PA/DP devices - RS4E5210 I/O List Engineering Package
- Access HART devices via PROFIBUS * When the I/O List Conversion Tools are used, Microsoft Excel
- Access 3rd Party multiplexers. (Excel 2013 64bit SP1 or later / Excel 2010 64bit SP2 or later)
is required to be installed in the FieldMate Validator PC.
User defined communication topology can be saved in
FDT project.
n External Interface Function (Tokuchu)
n Serial Number Acquisition This is the enhance communication function.
Applicable device: HART EJX and EJA series This function provides the capability of uploading Field-
Acquires serial number of the device and updates it in Mate data to the management system and downloading
the Device Maintenance Information. Also exports the any information to FieldMate for plant maintenance.
following information to a file. Also, FieldMate can communicate with non-standard
- Serial Number communication protocol field devices.
- Device Tag This function is provided as a special order (Tokuchu).
- Device ID For any inquiries, please contact FieldMate support
- Device Revision desk
- Model and Suffix Code <FIELD-MATE-SUPPORT-DESK@ml.jp.yokogawa.
com>.
n Device Replacement Tool
Applicable device: HART EJX and EJA series 3. Connection Example (for reference)
: Modbus EJX910 Sample BRAIN or HART configuration, connecting a
Uploads the device parameters and converts them for pressure transmitter.
use by the replacement device. [Required Components]
Applicable parameters: Tag, Long Tag, Descriptor,
Message, LRV, URV, Unit, Press Damp, Xfer function, l BRAIN or HART EJA Pressure Transmitter.
etc. l 24 V DC Power supply
l Load Resistor (250 10%)
n AXF Verification Tool l USB FieldMate Modem: BRAIN/HART
(/VF option)
Verifies Magnetic flowmeters (AXF) and supports two
types of verification. One is standard verification to
verify it without having to disconnect from a process
line. And another is enhanced verification to verify it
more precise than standard one. The Verification result
can be printed and stored in the Device Maintenance
EJA
Information.
Applicable device: HART Magnetic Flowmeter AXF
series
Necessary other items for Enhance verification: AM012 Magnetic
Flow Converter, CA150 HANDY CAL (or equivalent device) and
Insulation checker
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
<<Contents>> <<Index>> 4
4. System Requirements
Software Operating Environment
OS Windows 10 Pro, Home 32bit / 64bit (Anniversary Update version 1607 build, Creators
Update version 1703 build)
Windows 7 Professional, Home Premium 32bit/64bit SP1 or later *6
OS Language English, Japanese, Chinese (simplified), German, French, Russian *7
Hardware Operating Environment
Windows 10 Windows 7
CPU 1gigahertz (GHz) or faster processor
Main Memory 2GB or more
Hard disk space 4GB or more
DVD-ROM Drive Windows 10 compatible Windows 7 compatible
Display 1024768 or better resolution 1024768 or better resolution
recommended recommended
Windows 10 compatible Windows 7 compatible
Network port
Windows 10 Windows 7
BRAIN Interface One USB port USB2.0 standard
HART Modem USB FieldMate Modem: BRAIN/HART (Yokogawa Option)
FOUNDATION Interface One PCMCIA card slot
fieldbus H1 *1 Interface board NI PCMCIA-FBUS Series 2 (National Instruments)
Driver NI-FBUS Communications Manager 15.0 or later
FOUNDATION Interface One USB port USB2.0 standard
fieldbus H1 *1 Interface board NI USB-8486 (National Instruments)
Driver NI-FBUS Communications Manager 15.0 or later
PROFIBUS Interface One USB port USB2.0 standard
Interface card PROFIusb (Softing)
commDTM & driver PROFIdtm V2.11.01 or later PROFIdtm V2.11.01 or later
Driver V5.46.8 or later Driver V5.46.8 or later
DP/PA coupler KFD2-BR-A.PA.93 (PEPPERL+FUCHS)
6ES7 157-0AC80-0XA (SIEMENS)
Interface One USB port USB2.0 standard
Interface card PBproUSB (Softing)
commDTM & driver PROFIdtm V2.11.01 or later PROFIdtm V2.11.01 or later
Driver V5.46.8 or later Driver V5.46.8 or later
DP/PA coupler KFD2-BR-A.PA.93 (PEPPERL+FUCHS)
6ES7 157-0AC80-0XA (SIEMENS)
HART Interface Bluetooth 2.0
Modem VIATOR Bluetooth Interface: Model 010041 (MACTek ) *2
ISA100.11a *3 Interface One USB port USB2.0 standard
Modem Infrared Adapter : ACT-IR224UN-LN96-LE 9600bps (ACTiSYS) *4
Driver Version 1.5.0 / Version 1.12.0 *8 Version 1.7.0 *9
ISA100.11a *5 Interface One Ethernet port
Modbus Serial Interface One USB port USB2.0 standard
Modem Isolated RS422/485 USB adaptor
Not supported
SP390A-R2 (BLACK BOX)
Driver Version 2.0.0 or later
Login
Account Administrator privilege
Communication performance depends on environment and interface you select.
*1 FieldMate should connect to the devices in FOUNDATION fieldbus H1 segment without host system
*2 Microsoft supplied Bluetooth stack is used
*3 ISA100.11a OOB infrared communication
*4 Holder for Infrared Adapter is available (recommended): Gorillamobile Original: GM1 (JOBY, Inc).
*5 ISA100.11a communication via gateway
*6 FieldMate Validator is supported with Windows 10 Pro 64bit and Windows 7 Professional 64bit.
*7 FieldMate Validator is supported with an English OS and a Japanese OS.
*8 Version 1.5.0 driver is used for PL2303 HA/HXA chip and Version 1.12.0 driver is used for PL2303TA chip
*9 Interface recommends to use the driver included OS. Version 1.7.0 driver is used if interface does not work well.
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
<<Contents>> <<Index>> 5
5. Model and Suffix Codes
Field device management software package: FieldMate Release: R3.03
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
<<Contents>> <<Index>> 6
6. External View EMC Conformity Standards , , ,
External view of USB FieldMate modem: BRAIN/HART l CE
EN61326-1 Class A, Table1 (Basic immunity test
Unit : mm
requirement)
RoHS directive: EN50581
RoHS directive compliant products are as follows.
Shipping after 20th April 2016
46
lK C Mark
Registration No: KCC-REM-YHQ-EEN260
l RMC
EN61326-1 Class A, Table1 (Basic immunity test
requirement)
l EAC
18
EN61326-1 Class A, Table1 (Basic immunity test
requirement)
7. Included Items
FieldMate includes the following items:
* Software and Users Manual of FieldMate Validator are not
included. Please download Software and Users Manual of
FieldMate via Yokogawa web site.
<Product>
l CD-ROM: FieldMate Software Media
83 F003.ai
l DVD-ROM: Device Files Media
Fig. 3: USB FieldMate Modem l USB FieldMate modem: BRAIN/HART w/ cables
(optional)
Total cable length: Approximately 2.3 m <Documentation>
Techinical Specifications USB Interface l License number sheet
SOFTWARE l Getting Started
Please download Users Manual via Yokogawa web site.
USB Interface USB2.0 standard *1
http://www.yokogawa.com/fieldmate/
ELECTRICAL
Power Supply System powered by USB Port
8. Items Contained in Media
Supply Current 40mA@ + 5 V
Pins to Computer USB Type-A connector
n Items contained in the Media of FieldMate
R3.03:
2-pin, polarity insensitive Mini-
Pins to Device grabber test clips. Detachable CD-ROM: FieldMate Media
alligator clips addtionally l FieldMate Program
0.5 + / - 0.1 Vpp trapezoidal l USB modem driver
Output Level (HART)
wave@1200/2200 Hz DVD-ROM: Device Files Media
Output Level (BRAIN)
1.0 + / - 0.1 Vpp trapezoidal l Device DTM for Yokogawa devices
wave@2400 Hz - BRAIN
1910 VDC between instru- - FOUNDATION fieldbus H1
Isolation(DC)
ment and computer - HART
Isolation(AC) 1350 Vrms (50Hz) - PROFIBUS
ENVIRONMENTAL - ISA100.11a
Operating Temperature 0 C to 55 C - Modbus
l Device DTM for the HART devices *1
Storage Temperature -40 C to 70 C
l Built-in DTMs (DTM interprets DD and works right
Storage Humidity 0% to 95% relative humidity straight.)
PHYSICAL DIMENSIONS - FOUNDATION fieldbus H1
Enclosure
83 x 46 x 18 mm, ABS indus- - HART
trial enclosure - ISA100.11a
190 cm, 2-conductor l DD for the FOUNDATION fieldbus H1 devices *2
Device Interface Cable terminating with two mini grab- l DD for the HART devices *1
ber clips
27 cm cable terminating in a *1: Devices registered with HART Communication
USB Cable Foundation, some DTM or DD may not be included.
USB type A connector
*2: Devices registered with Fieldbus FOUNDATION,
*1: USB2.0 also covers USB1.1
some DD may not be included.
Remarks:
Yokogawa certifies the quality and operability only of DD
and DTM which have been registered by Yokogawa.
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
<<Contents>> <<Index>> 7
9. Compatibility
Compatibility between FieldMate and Device Files is
indicated on the web site at the following URL.
For more information, see the System Requirements.
http://www.yokogawa.com/fieldmate/
11. Trademarks
All brand or product names of Yokogawa Electric
Corporation in this document are trademarks
or registered trademarks of Yokogawa Electric
Corporation.
All other company brand or product names in this
document are trademarks or registered trademarks of
their respective holders.
All Rights Reserved. Copyright 2006, Yokogawa Electric Corporation GS 01R01A01-01E Aug. 14, 2017-00
Subject to change without notice.