Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Gs01c25r51-01en (7) Fas120

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

<<Contents>> <<Index>>

General R1.05
Specifications FSA120
Flow Configuration Software
GS 01C25R51-01EN

1. Features Device Management


The FSA120 (FieldMate FlowNavigator) is the software Online parameter
package which offers various functions to help users to The general parameters of the device can be
easily configure the mass flow parameters of device. edited directly in online status.
The FSA120 includes following two programs: Offline parameter
• EJXMVTool: for EJX Multivariable Transmitter The general parameters of the device can be
• DYFMVTool: for digitalYEWFLO Vortex Flowmeter edited and stored in offline database.
FSA120 includes FieldMate, Yokogawa’s frame
application. It employs FDT/DTM technology and works Note for FOUNDATION fieldbus
on the FieldMate. • The function blocks supported by Device
Management are as follows;
FSA120 has the following features: EJX Multivariable Transmitter:
• Easy flow parameter configuration by dialog Resource block, Sensor Transducer block,
windows Flow Transducer block, LCD Transducer block,
• Configuration of the fluid physical properties* and AI function blocks
*: DIPPR, Steam tables IAPWS-IF97, Natural gas digitalYEWFLO Vortex Flowmeter:
standard AGA8/ISO12213 Resource block, Transducer block, AI function
• Configuration of the primary device** blocks and AR function block
**: Orifice, Nozzle, Venturi, FIX Download/upload
• Various flow calculation modes Downloading the flow and general parameters to
EJXMVTool: Auto Compensation Mode / Basic the device. Uploading the data from the device to
Mode PC.
DYFMVTool: Detail Compensation Mode /
Steam Compensation Mode / Simple Flow Configuration Wizard
Compensation Mode
In this mode, the procedures which are required for
• HART and FOUNDATION fieldbus H1 are supported.
flow configuration can be performed interactively.
FSA120 provides following advantages to device: (1) Auto Compensation Mode (EJXMVTool),
• Highly-responsive flow measurement and saving Detail (Gas / Liquid) Compensation Mode
cost by built-in flow computer inside device (DYFMVTool)
• Highly-accurate mass flow rate output Procedures to configure flow calculation by setting
compensated by process temperature or pressure up a primary device and fluid physical properties in
value by using the fluid physical properties a step-by-step in dialog window.
database (2) Basic Mode (EJXMVTool), Simple (Gas /
• Easy mass flow configuration by FDT/DTM Liquid) Compensation Mode (DYFMVTool),
standard conforming software Steam Compensation Mode (DYFMVTool)
FieldMate: Yokogawa’s frame application which Flow operation and density compensation are
conforms to FDT standard performed as follows.
FDT (Field Device Tool): defines the system environment • With the flow factors being input manually (Basic
in which the DTM runs. Mode/ Simple (Gas / Liquid) Compensation
DTM (Device Type Manager): the application which Mode)
defines the graphical user interface (GUI) specific • With the flow factors inside digitalYEWFLO
to the device. Vortex Flowmeter (Steam Compensation Mode)
Remarks: For FSA120 R1.04 or later, the product name
has been changed to “FieldMate FlowNavigator” (3) Import/export file
from “EJXMVTool”. Import and export the user flow parameters.
(4) Report
2. Functional Details The list of user flow parameters is exported in CSV
file format.
FieldMate Basic is bundled, which supports the online
device parameter configuration while it is connected Obtain Flow coefficient (for EJXMVTool)
to the device. If the offline parameter configuration is
required, specify FieldMate Advance (option code: /Y). The flow coefficient can be obtained from the device.
Input selection: sensor data actually measured or
simulated data input by user.

Yokogawa Electric Corporation GS 01C25R51-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Aug. 2006
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 7th Edition Aug. 2012
<<Contents>> <<Index>> 2
Specification of Auto Compensation Mode <Hardware Operating Environment>
(EJXMVTool) and Detail Compensation • PC
Mode (DYFMVTool) - Machine: IBM PC/AT compatible
Supported primary device (for EJXMVTool) Windows 7 Windows Vista
The 19 devices or Fixed Mode as specified in Table CPU Intel® Core™2 Duo T7100 or similar
1. specification CPU
Fixed Mode:
Main Memory 2GB or more 1GB or more
Set a fixed value to Discharge coefficient and Gas (2GB or more
expansion factor. recommended)
Density compensation Hard Disk Drive 8GB or more
Following (1) and (2) methods are supported for DVD-ROM Windows 7 Windows Vista
density compensation. For unsupported fluid, data Drive compatible compatible
entries to configure custom physical properties are Display 1024×768 or 1024×768 or
also available as shown in (3). better resolution better resolution
(1) Density compensated by physical properties recommended recommended
Windows 7 Windows Vista
Database: compatible compatible
As specified in Table 2
Source: • Network port
American Institute of Chemical Engineers For HART device:
(AIChE®) DIPPR® Project No.801 Database: One USB port USB 2.0 standard / Bluetooth 2.0
2003 Edition For FOUNDATION fieldbus H1 device:
(2) Density compensated using standard PCMCIA card slot / One USB port USB2.0
standard
Natural gas:
AGA8 <Software Operating Environment>
Compressibility Factors of Natural Gas and Common requirement:
Other Related Hydrocarbon Gases. • Windows
American Gas Association (AGA) Windows 7 Professional 32bit/64bit /Home
Transmission Measurement Committee Report Premium 32bit/64bit SP1 or later (English)
No.8 Second Edition, November 1992 Windows Vista business 32bit SP2 or later
Detail Characterization Method (English)
Gross Characterization Method 1 • Adobe Reader
Gross Characterization Method 2 • Frame application: FieldMate R2
ISO 12213:1997 First edition 1997-12-01 • Communication DTM (included in FieldMate)
Part 2: molar-composition analysis Requirement for FOUNDATION fieldbus:
Part 3: physical properties • NI-FBUS Communications Manager
Steam tables (for EJXMVTool): Windows Vista, Windows 7: 4.0.1 or later
IAPWS-IF97 Water and Steam (1997) • Function Block Scheduling and Connection Tool
IAPWS-IF97: IAPWS Industrial Formulation 1997 (For DYFMVTool)
IAPWS: The International Association for the e.g.NI-FBUS Configurator
Properties of Water and Steam. Windows Vista, Windows 7: 4.0.1 or later
(3) Custom fluid density and viscosity
compensation: 4. Model and Suffix Codes
Numerical value can be input to configure physical R1.05
properties (density, viscosity, etc.)
Model Suffix Codes Descriptions
FSA120 . . . . . . . . . . . . . Flow Configuration Software***
3. System Requirements License -S . . . . . . . . . . . . Single PC License*
The quality and operability of the FlowNavigator are
─ 1 . . . . . . . . . . Always 1
certified for use with FieldMate only. The operational
condition depends on frame application. The followings ─ 1 . . . . . . . . Always 1
describe the operating conditions of FieldMate. ─ 0 . . . . . . Always 0
Optional code /Y . . . . FieldMate Advance License**
/B . . . . USB FieldMate Modem attached
*: Single user on a single PC
**: If the parameter configuration while it is not
connected to the device is required, specify this
option code.
***: For FSA120 R1.03 or before, “EJX-MV
configuration DTM” was used.

All Rights Reserved. Copyright © 2006, Yokogawa Electric Corporation GS 01C25R51-01EN Aug. 08, 2012-00
<<Contents>> <<Index>> 3
Models to be connected <RELATED INSTRUMENTS AND SOFTWARE>
• EJX Multivariable Transmitter EJX910A Multivariable Transmitter:
EJX910A/EJX930A GS 01C25R01-01EN
Protocol: HART, FOUNDATION fieldbus EJX930A Multivariable Transmitter:
• digitalYEWFLO Vortex Flowmeter GS 01C25R04-01EN
DY-F/DYA-F Model DY Vortex Flowmeter, Model DYA Vortex Flow
Protocol: FOUNDATION fieldbus Converter: GS 01F06A00-01EN
Device Type: 9, Device revision: 3 or later Model DY, Model DYA FOUNDATION Fieldbus
Communication Type Vortex Flowmeter:
Recommended Communications interface GS 01F06F01-01EN
FieldMate: GS 01R01A01-01E
HART:
Yokogawa USB HART Modem
(Parts number: F9197UB) Table 1. Supported primary Devices
Yokogawa USB FieldMate modem
Type Primary Device
(Parts number: F9197UC)
VIATOR ® Bluetooth ® Interface Orifice Orifice Corner Taps [ISO5167-1 1991]
(Model 010041 (MACTek ®)) * Orifice Corner Taps [ISO5167-2 2003]
FOUNDATION fieldbus: Orifice Corner Taps [ASME MFC-3M 1989]
Softing Orifice Flange Taps [ISO5167-1 1991]
FFusb ** Orifice Flange Taps [ISO5167-2 2003]
National Instruments Orifice Flange Taps [ASME MFC-3M 1989]
PCMCIA-FBUS Series 2 Orifice Flange Taps [AGA No.3 1992]
NI USB-8486
Orifice D and D/2 Taps [ISO5167-1 1991]
*: Microsoft supplied Bluetooth stack is used. Orifice D and D/2 Taps [ISO5167-2 2003]
**: The package is provided complete with FieldMate Orifice D and D/2 Taps [ASME MFC-3M 1989]
driver from Softing.
Nozzle ISA1932 nozzle
Components [ISO5167-1 1991/ ISO5167-3 2003]
Long radius nozzle
FSA120 includes the following items: [ISO5167-1 1991/ ISO5167-3 2003]
<FlowNavigator> ASME FLOW NOZZLES [ASME MFC-3M 1989]
• CD-ROM: FlowNavigator Venturi Venturi nozzle [ISO5167-1 1991/ ISO5167-3 2003]
• License number sheet for FlowNavigator
Classical Venturi tube “as cast” convergent section
• Getting started and Software License Agreement [ISO5167-1 1991/ ISO5167-4 2003]
for FlowNavigator
ASME Venturi Tubes With a rough Cast or
<FieldMate> Fabricated Convergent [ASME MFC-3M 1989]
• CD-ROM: FieldMate Classical Venturi tube with a machined convergent
• DVD-ROM: Device Files section [ISO5167-1 1991/ ISO5167-4 2003]
• Licence number sheet for FieldMate ASME Venturi Tubes With a machined convergent
For the details, refer to GS 01R01A01-01E. section [ASME MFC-3M 1989]
• Getting started and Operational Precaution for
Classical Venturi tube with a rough-welded sheet-iron
FieldMate convergent section
<Modem> (Option) [ISO5167-1 1991/ ISO5167-4 2003]
• USB FieldMate modem: BRAIN/HART, with cables FIX Fixed Mode (Sets the discharge coefficient and gas
For the details, refer to GS 01R01A01-01E. expansion factor to a fixed value)
*: Compatibility
Compatibility between FieldMate and Device Files
is indicated at the following URL.
https://voc.yokogawa.co.jp/PMK/

Trademarks
All the brand names or product names of Yokogawa
Electric used in this document are either trademarks
or registered trademarks of Yokogawa Electric
Corporation.
All the brand names or product names of other
companies mentioned in this document are either
trademarks or registered trademarks of their
respective holders.

All Rights Reserved. Copyright © 2006, Yokogawa Electric Corporation GS 01C25R51-01EN Aug. 08, 2012-00
<<Contents>> <<Index>> 4
Table 2. Supported physical Properties database

Fluid name Fluid name Fluid name


Acetic Acid (*) Isobutane Toluene
Acetone Isobutene Trichloroethylene
Acetonitrile Isobutylbenzene Trichlorouoromethane
Acetylene Isopentane Vinyl Acetate
Acrylonitrile Isoprene Vinyl Chloride
Air Isopropanol Vinyl Cyclohexene
Allyl Alcohol m-chloronitrobenzene Water
Ammonia m-dichlorobenzene 1-Butene
Argon Methane 1-Decene
Benzaldehyde Methanol 1-Decanal
Benzene Methyl Acrylate 1-Decanol
Benzoic Acid (*) Methyl Ethyl Ketone 1-Dodecene
Benz Alcohol Methyl Vinyl ether 1-Dodecanol
Biphenyl Monochlorobenzene 1-Heptanol
Bromine n-Butane 1-Heptene
Carbon Dioxide n-Butanol 1-Hexene
Carbon Monoxide n-Butyraldehyde 1-Hexadecanol
Carbon Tetrachloride n-Butyronitrile 1-Octanol
Chlorine n-Decane 1-Octene
Chlorodiuoromethane n-Dodecane 1-Nonanal
Chloroprene n-Heptadecane 1-Nonanol
Chlorotriuoroethylene n-Heptane 1-Pentadecanol
Cycloheptane n-Hexane 1-Pentanol
Cyclohexane n-nonane 1-Pentene
Cyclopentane n-Octane 1-Undecanol
Cyclopentene n-Pentane 1,1,2,2-Tetrauoroethane
Cyclopropane Neon 1,1,2-Trichloroethane
Dichlorodiuoromethane Neopentane 1,2,4-Trichlorobenzene
Divinyl Ether Nitric Acid (*) 1,2-Butadiene
Ethane Nitric Oxide 1,3-Butadiene
Ethanol Nitrobenzene 1,3,5-Trichlorobenzene
Ethylamine Nitroethane 1,4-Dioxane
Ethylbenzene Nitrogen 1,4-Hexadiene
Ethylene Nitromethane 2-Methyl-1-Pentene
Ethylene Glycol Nitrous Oxide 2,2-Dimethylbutane
Ethylene Oxide Oxygen *: Only for liquid.
Fluorene Pentauoroethane
Furan Phenol
Helium-4 Phosphoric Acid (*)
Hydrazine Propadiene
Hydrogen Propane
Hydrogen Chloride Propylene
Hydrogen Cyanide Pyrene
Hydrogen Peroxide Styrene
Hydrogen Sulde Sulfur Dioxide

All Rights Reserved. Copyright © 2006, Yokogawa Electric Corporation GS 01C25R51-01EN June 07, 2010-00
Subject to change without notice.