DCA-25ESK: Denyo

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PH 1800 REDSTAR

www.redstarequipment.com.au

DENYO DCA-25ESK
PRIME POWER GENERATOR Three Phase

SPECIFICATIONS
ALTERNATOR
General
Frequency 50 Hz
The DCA series generators are complete, stand
Output Continuous/Standby 20/22KVA alone generating sets. All models consist of an
Rotating Speed 1500RPM alternator which is directly coupled to a diesel
NO. Of Phases Three Phase 4 wire engine. The alternator and engine are set on a
Rated Voltage 380/440 common skid base. Special Vibration isolators
Power Factor 0.8 are used to minimize vibrations during opera-
Voltage Regulation % +1.5 tion. The generator and electrical components
are fully enclosed in a solid steel, weatherproof
Excitation Brushless, Rotating Exciter
canopy. Noise suppression is achieved by using
(with A.V.R.)
highly effective sound insulation materials.
Insulation Class F
50Hz/60Hz Operation
The DCA series can be operated at either 50Hz
ENGINE or 60Hz by simply adjusting the engine speed
Make & Model Kubota V2203-EB using the throttle control knob on the control
Type Inlined, Swirl Chambered panel.
Output Rating 25.0/1500 PS/rpm
Auto Fuel Air Extractor
18.4/1500 KW/min-1 Air trapped in the fuel system can be trouble-
No. of Cylinders-Bore X Stroke 4-87 x 92.4mm some, however, with the DCA series, fuel air
Piston Displacement 2.197L extraction is automatically performed by simply
Fuel Diesel operating the starter switch, without the need
Fuel Consumption 3.9 L/H for tools or devices. There is no soiling of the
Lube Oil Sump Cap 7.6L machines interior or the operators hands and
the outflow of fuel to the machines exterior
Coolant Capacity 7.9L
is prevented. The machine will start after the
Battery Capacity 12 60x1pc
engine is turned over a few times.
Fuel Tank Capacity 62L
Extremely Quiet Operation
In urban areas and at the worksite, there is an
SOUND ever increasing demand for reduced noise.
7m/dB (A) 1500/1800rpm 62dB The DCA series generators are extremely quiet
when operating at full load.

Clean engines
UNIT The engines used in these generators meet all
Dimensions (L/W/H mm) 1540x 650x 900 Californian Atmospheric Pollution standards,
Dry Weight 591kg which is one of the worlds most stringent an-
tipollution standards. This is achieved by using
a PCV purge control valve system. Therefore,
these engines do not discharge blow-by gas
to the outside, which keeps the interior of the
machine cleaner and the exhaust emissions are
minimized.