Huang D D 2014
Huang D D 2014
Huang D D 2014
Daocheng Huang
Doctor of Philosophy
in
Electrical Engineering
Daocheng Huang
ABSTRACT
electronics, the power supplies for telecoms, servers, desktops, laptops, flat-panel TVs,
LED lighting, etc. are required for more efficient power delivery with smaller spaces. The
LLC resonant converter has been widely adopted for these applications due to the
advantages in high efficiency, high power density and holdup time operation capability.
However, LLC resonant converter meets some issues, especially in high output
To solve those issues, like start-up and short-circuit protection, SR driving and EMI, etc., a
synthesis method is proposed to find the similar resonant topologies like LLC. Based on
this method, lots of multi-element resonant converters are found to solve the issues that
utilized. Based on it, the voltage stress, current stresses and apparent power of resonant
converters are easy to compare. This method can help select suitable circuit topology for
certain applications. Meanwhile, it also can help resonant converters’ design. The
integration and EMI performance, are also taken into account for the whole evaluation
system.
The high switching frequency is needed recently for high power density requirement.
However, LLC resonant converter suffers high transformer loss. Matrix transformer is
introduced to reduce winding loss and total volume. Flux cancellation method is utilized to
reduce core size and loss. Synchronous Rectifier (SR) devices and output capacitors are
integrated into secondary windings to eliminate termination related winding losses, via loss and
The passive integration is necessary for high power density resonant converter,
especially for high order system. Based on stress, suitable passive components are chosen
for integration. Then, the magnetic integration method is shown based on multi-winding
transformer structure. The passive integration principles are discussed. A novel passive
In conclusion, this work is focus on the topology analysis and integration of resonant
converters. Searching the suitable topologies for certain application, and evaluate the
performance of them. Then, improve the system power density by integration techniques.
iii
To My Family:
My parents: Liugen Huang
Fengling Luo
iv
Acknowledgments
First I would like to express my sincere gratitude to my advisor, Dr. Fred C. Lee. It
is him who shows me how to climb the mountain of research and see the beautiful
scenery of power electronics. It is his depths of knowledge and experience that gave me
the power to break the rock blocking my research path. Besides his board knowledge, his
rigorous research attitude and logical way of thinking have been a great value for me.
I would like to thank Dr. Dushan Boroyevich for his valuable guidance during my
research. I am also grateful to his enthusiastic help during the CPES annual conference
when I was the fresh chairman. I also want to acknowledge the other members of my
advisory committee, Dr. Paolo Mattavelli, Dr. Jaime De La Ree and Dr. Dwight Viehland
Consortium Group. It has been a great pleasure to work with the talented, creative,
helpful and dedicated colleagues. I would like to thank all the members of our teams: Dr.
Ming Xu, Dr. Shuo Wang, Dr. Julu Sun, Dr. Authur Ball, Dr. Yan Jiang, Dr. Jian Li, Dr.
Yan Dong, Dr. Chuanyun Wang, Dr. Dianbo Fu, Dr. Pengju Kong, Dr. David Reusch,
Dr. Qiang Li, Dr. Zheng Zhao, Dr. Mingkai Mu, Dr. Yingyi Yan, Dr. Weiyi Feng, Mr.
Doug Sterk, Mr. Bin Huang, Mr. Yucheng Ying, Mr. Yi Sun, Mr. Ya Liu, Mr. Clark
Person, Mr. Zheng Luo, Mr. Pengjie Lai, Mr. Zijian Wang, Mr. Qian Li, Ms. Yin Lu, Mr.
Chanwit Prasantanakorn, Mr. Shu Ji, Mr. Feng Yu, Mr. Haoran Wu, Mr. Yipeng Su, Mr.
Wei Zhang, Mr. Li Jiang, Mr. Shuilin Tian, Mr. Pei-Hsin Liu, Dr. Dongbin Hou, Mr.
v
Zhiqiang Wang, Mr. Xiucheng Huang, Mr. Zhengyang Liu, Mr. Yucheng Yang, Mr.
Yang Jiao, Mr. Sizhao Lu, Mr. Chao Fei, Mr. Xuebing Chen, Ms. Yincan Mao, Mr.
Zhongsheng Cao, Mr. Syed Bari. Dr. Marcos Alonso, Dr. Fang Luo, Dr. Ke Jin, Dr.
Xiaoyong Ren, Dr. Fanghua Zhang, Dr. Yuling Li, Dr. Shaojun Xie, Dr. Xinke Wu, Dr.
Brian Cheng, Dr. Feng Wang, Dr Xin Ming, Dr. Feng Zheng.
My thanks also go to all of the other students I have met in CPES, especially to Dr.
Jing Xu, Dr. Michele Lim, Dr. Yan Liang, Dr. Rixi Lai, Dr. Honggang Sheng, Dr. Di
Zhang, Dr Puqi Ning, Dr. Tim Thacker, Dr. Carson Baisden, Dr. Xiao Cao, Dr. Zhiyu
Shen, Dr. Ruxi Wang, Dr. Dong Jiang, Dr. Dong Dong, Dr. Hemant Bishnoi, Dr. Zhen
Chen, Ms. Yiying Yao, Mr. Jing Xue, Ms. Zhuxian Xu, Mr. Zheyuan Tan, Mr. Xuning
Zhang, Mr. Bo Wen, Mr. Lingxiao Xue, Mr. Zhemin Zhang, Mr. Bo Zhou, Mr. Ying
I would also like to thank all the wonderful staffs in CPES: Ms. Linda Gallagher,
Ms. Teresa Rose, Ms. Marianne Hawthorne, Ms. Linda Long, Mr. Robert Martin, Mr.
Jamie Evans, Mr. Dan Huff, Dr. Wenli Zhang and Mr. David Gilham for their support
and help over the past six years. I also hope give my special thanks to Ms. Teresa Shaw
With much love and gratitude, I want to thank my parents: my mother Fengling Luo
and my father Liugen Huang for their endless love, encouragement, and support
Special thanks go out to the CPES PMC mini-consortium members for the funding
vi
Electronics, Huawei Technologies, Infineon Technologies, International Rectifier, Linear
vii
Table of Contents
Chapter 1. Introduction ................................................................................... 1
1.2.2 Limitation of PWM DC-DC Converter with Hold-up Time Requirement ..............6
1.3.2 Advantages of LLC Resonant Converter (LLC) with Hold-up Time Requirement13
viii
1.6.3 Wide Band Gap Devices —GaN HEMT ...............................................................31
2.6 LLC-like Resonant Converters with Notch Filter and Two Band-pass Filters ............ 62
ix
4.2 Matrix Transformer with Flux Cancellation .............................................................. 101
4.3 Winding Structure Integrated with Synchronous Rectifier Devices .......................... 109
References ...................................................................................................162
x
List of Figures
Fig. 1.1 Ac-dc front-end converter ........................................................................................................... 2
Fig. 1.2 Efficiency trend for ac-dc front-end converters of redundant, datacenter applications .................. 3
Fig. 1.7 Holdup time capacitance vs. input voltage range for dc-dc converters of the front-end converter . 7
Fig. 1.8 Duty cycle range for PWM converter with hold up requirement. ................................................. 8
Fig. 1.9 Simplified general isolated dc/dc PWM converter block diagram ................................................ 9
Fig. 1.10 Simplified general isolated dc/dc resonant converter block diagram .......................................... 9
Fig. 1.19 Commercial products comparison with LLC DC/DC and PWM DC/DC ................................. 17
Fig. 1.24 Desired SR gate driving signals in different switching frequency regions ................................ 20
xi
Fig. 1.25 SR gate driving signals by secondary current sensing .............................................................. 21
Fig. 1.28 Circuit schematic of the conventional transformer and SR structure. ....................................... 24
Fig. 1.30 CM noise spectrum comparison of PWM and LLC resonant converters. .................................. 25
Fig. 1.37 Specific on-resistance versus breakdown voltage for GaN and Si ............................................ 32
Fig. 2.1 Simple Block diagram for the basic concept of resonant converter ............................................ 37
Fig. 2.2 Zero current switching and zero voltage switching principles .................................................... 37
Fig. 2.5 Circuit and voltage gains of LCC resonant converter ................................................................. 41
Fig. 2.6 Circuit and voltage gains of LLC resonant converter ................................................................. 42
xii
Fig. 2.13 Voltage gains and tanks of Notch+PRF ................................................................................... 47
Fig. 2.21 Desirable Gain Curves for LLC-like resonant converters ......................................................... 54
Fig. 2.25 Four-element resonant topology networks including Network 2(SRF) ..................................... 58
Fig. 2.26 Four-element resonant topology networks including Network 2(SRC) and Network 1(PRF).... 59
Fig. 2.27 Four-element resonant topology networks including Network 2(SRC), Network 1(PRF) and
Fig. 2.28 Four-element resonant topologies including Network 2 (SRC), Network 1(PRF) and Network 3
or 4 (NRF)............................................................................................................................................. 60
Fig. 2.29 Four-element resonant topologies with desired resonant frequencies ....................................... 61
Fig. 2.31 Power Delivery Difference between LLC & 5-e ...................................................................... 63
Fig. 2.33 Five element resonant tank cell based on LLC with notch filter and 3rd harmonics band filter .. 64
Fig. 2.34 Experimental results for 5-element resonant converters under full load.................................... 66
Fig. 2.35 Experimental results of 5-element resonant converters under short-circuit condition................ 66
xiii
Fig. 3.1 Equivalent circuit of stage I ...................................................................................................... 68
Fig. 3.19 LLC and CLL state-plane comparison based on conventional normalization ........................... 81
Fig. 3.23 V-I stresses of LLC resonant converters for Ln=12.5 ............................................................... 85
Fig. 3.24 V-I stresses of LLC resonant converters for different Ln .......................................................... 85
xiv
Fig. 3.26 V-I stresses of LCL resonant converters for different Ln .......................................................... 87
Fig. 3.28 V-I stresses ofCLL resonant converters for different Ln ........................................................... 88
Fig. 3.29 V-I stresses ofthree-element resonant converters for different Ln ............................................. 88
Fig. 3.30 V-I stresses of three-element resonant converters for different Ln ........................................... 89
Fig. 3.32 Startup Comparison of LLC, CLL & LCL Resonant Converters .............................................. 91
Fig. 3.33 SR drive Comparison of LLC, CLL & LCL Resonant Converters ........................................... 92
Fig. 3.36 CM noise spectrum of LLC, CLL & LCL Resonant Converters............................................... 94
Fig. 3.37 CM noise spectrum of LLC, CLL & LCL Resonant Converters............................................... 95
Fig. 4.4 LLC resonant converter with four sets output .......................................................................... 102
Fig. 4.5 12 layer PCB structure with one core and its MMF ................................................................. 103
Fig. 4.6 12 layer PCB structure with two cores and its MMF................................................................ 104
Fig. 4.7 LLC Resonant Converter with Matrix Transformer Structure .................................................. 105
Fig. 4.8 Four layer PCB structure with four cores and its MMF ........................................................... 106
Fig. 4.9 Primary side winding pattern with four U-I cores matrix transformer ...................................... 106
Fig. 4.10 Rearranged primary side winding pattern with four U-I cores ................................................ 107
Fig. 4.11 Primary side winding pattern for two E-I core matrix transformer ......................................... 107
Fig. 4.12 Primary side winding pattern for two core matrix transformer with flux cancellation ............. 108
Fig. 4.13 LLC resonant converter with proposed transformer structure................................................. 108
xv
Fig. 4.14 Top view of 1st winding arrangement ................................................................................... 110
Fig. 4.15 Cross view of the first winding arrangement and its MMF .................................................... 111
Fig. 4.16 AC current distribution for secondary winding of the first winding arrangement.................... 111
Fig. 4.17 FEA simulation for the first winding arrangement ................................................................. 112
Fig. 4.18 FEA simulation for the first winding arrangement with output shorted .................................. 113
Fig. 4.19 FEA simulation for the first winding arrangement with secondary winding shorted ............... 114
Fig. 4.21 Cross view of the second winding arrangement ..................................................................... 115
Fig. 4.22 FEA simulation for the second winding arrangement ............................................................ 116
Fig. 4.27 The circuit of 1kW, 400V/12V LLC resonant converter prototype ......................................... 120
Fig. 4.28 The prototype of 1kW, 400V/12V LLC resonant converter ................................................... 121
Fig. 4.29 Experimental waveforms for 15% load condition .................................................................. 122
Fig. 4.30 Experimental waveforms for 50% load condition .................................................................. 122
Fig. 4.31 Experimental waveforms for 100% load condition ................................................................ 123
Fig. 4.32 The efficiency comparison for CPES prototype and industry product .................................... 124
Fig. 5.2 Circuit and voltage gains of LLC resonant converter ............................................................... 129
Fig. 5.4 Gain Curves of selected 4-elements resonant converter ........................................................... 130
Fig. 5.5 V-I stresses of LLC and 4-element resonant converters ........................................................... 131
xvi
Fig. 5.7 Gain Curves of selected 5-elements resonant converter ........................................................... 132
Fig. 5.11 Equivalent circuit for discrete Cr, Cp and integrated magnetics .............................................. 137
Fig. 5.12 The gain curves of passive integration model ........................................................................ 137
Fig. 5.15 Volume comparison of proposed and traditional magnetic integration method ....................... 139
Fig. 5.16 Stress comparison for integrated magnetic module ................................................................ 140
Fig. 5.19 Interconnections and winding structure of an integrated LLCT module ................................. 143
Fig. 5.20 Exploded view of an LLCT module with the stacked structure .............................................. 144
Fig. 5.27 The final parameters of integrated transformer module .......................................................... 151
Fig. 5.28 The volume comparison of passive module and discrete components .................................... 151
Fig. 5.29 Integrated passive module with heat extractors ...................................................................... 153
xvii
Fig. 5.32 Picture of cores and heat extractors ....................................................................................... 155
Fig. 5.33 The volume comparison of passive module and discrete components .................................... 156
Fig. 5.34 Experimental results for five-element resonant converter with passive integration module..... 157
xviii
List of Tables
Table 4.1The AC resistance of pri and sec windings vs. thickness ........................................................ 120
Table 4.2 Loss breakdown of prototype under 100% load .................................................................... 124
Table 4.3 Loss breakdown of prototype under 15% load ...................................................................... 125
xix
Daocheng Huang Chapter 1
Chapter 1. Introduction
This chapter presents the motivations, objectives and overview of this dissertation. The
advantages of LLC resonant converters and its wide applications are investigated. The challenges
in LLC resonant converter are described. A review in this field is provided, followed by the
Over the past decade energy efficiency and power density have become the top concerns for
power conversions. Rising energy intensity leads to a higher cost for delivering power.
Meanwhile, the demand for compact power supplies grows significantly. It requires power
supplies with high efficiency, low profile and high power density.
computing systems, such as data centers, telecoms, servers, desktops, laptops and notebooks
have become a large market for the power supply industry. For the advance of the integrated
circuit technology, the density and functionality of computer systems are continually increasing,
which requires more efficient power delivery while smaller size on power suppliers [A.1]-
[A.11]. For consumer electronics, such as flat-panel TVs and LED lighting, high reliability, low
cost and high efficiency power supplies are demanded [A.12]-[A.15]. More ever, for the
prosperousness of the cloud computing and online service, energy saving and cost reduction
1
Daocheng Huang Chapter 1
Ac-dc front-end converters as shown in Fig. 1.1 are widely adopted by these applications.
Driven strongly by economic and environmental concerns, high efficiency is becoming more and
more desired for ac-dc front-end converters. The 80 PLUS programs provide a class of efficiency
requirements as shown in Fig. 1.2[A.9]. Take the 80 PLUS TITANIUM program as an example,
it provides the highest efficiency requirement for the front-end converters nowadays. The
certified power supplies are expected to achieve 91% efficiency at 100% load, 96% efficiency at
50% load, 94% efficiency at 20% load, and 90% efficiency at 10% load when converting 230V
ac power from electric utilities to dc power used in most electronics. Right now, some industry
benchmarks are beyond TITANIUM. The efficiency requirement at the dc-dc stage is even
continuously increasing as well [A.5]. Higher power density will eventually reduce the converter
cost and allow for accommodating more equipment in the existing infrastructures. As shown in
Fig. 1.3, in the past years, the power density of front-end commercial converters has increased by
more than twenty times. This will continuously increase in the future because of the fast
2
Daocheng Huang Chapter 1
Fig. 1.2 Efficiency trend for ac-dc front-end converters of redundant, datacenter applications
3
Daocheng Huang Chapter 1
however, they suffer high switching losses. Soft switching techniques can help the PWM circuit
achieve zero-voltage-switching (ZVS) so that lower switching loss and higher frequency can be
accomplished. Soft-switching PWM circuits, such as the phase-shift full-bridge PWM converter
widely used for front-end dc-dc conversion. These topologies are plotted in Fig. 1.4, respectively.
(a) Phase shift full bridge PWM converter (b) Asymmetry half bridge PWM converter
ZVS lost at light load is one drawback of soft-switching PWM converters. For PSFB, large
leakage inductance is needed to achieve ZVS. With large leakage inductance, the duty cycle loss
due to charge and discharge leakage inductance will be significant. This will limit the choice of
transformer turns ratio, which will affect the performance of whole converter. Even with large
leakage inductance, still ZVS cannot be achieved at light load. There are many different methods
4
Daocheng Huang Chapter 1
to expend ZVS region for phase shift full bridge[A.29], but they are not been widely adopted due
to complexity. Since AHB also utilizes leakage inductance to achieve soft switching, there is
similar problem as discussed for PSFB, which lost ZVS during light load condition.
High turnoff loss for primary devices is another drawback. As dash circled in Fig. 1.5, the
turnoff current of primary devices is around the highest point due to the trapezoid or square
No ZCS for synchronous rectifier (SR) generates large reverse recovery loss. As circled in
Fig. 1.5, the turnoff current of SR device is around the highest point due to the trapezoid or
(a) Phase shift full bridge PWM converter (b) Asymmetry half bridge PWM converter
5
Daocheng Huang Chapter 1
Passive components are hard to reduce volume. As mentioned above, the switching loss of
soft-switching PWM converters is not small, which limit the switching frequency increasing.
That means passive components are not easy to reduce volume. On the other hand, there are
usually two individual magnetic components in the circuit, the transformer and the output
inductor. Sometimes, an extra inductor is in series with transformer to help achieving ZVS. It is
The holdup time operation poses a major design challenge in front-end converters. As
shown in Fig. 1.6, the front-end ac-dc converters are required to maintain the regulated output
voltage for about 20ms when the input ac line is lost[A.30].As shown in Fig. 1.1, during the
holdup time, all the energy transported to the load comes from the bulk capacitor. The
requirement of this capacitor is determined by the system power level and the input voltage
range of the dc-dc converter. The relationship between holdup time capacitor requirement and
minimum dc-dc stage input voltage for 1kW front-end converter is shown in Fig. 1.7.Apparently,
the wider the dc-dc stage input voltage range is, the fewer bulky holdup time capacitors are
required, and the higher power density will be. Therefore, to meet the holdup time operation
requirement, the capability of operating within a wide input voltage range is required for the dc-
6
Daocheng Huang Chapter 1
Holdup time
VNORM
VBUS_MIN
20ms
Fig. 1.7 Holdup time capacitance vs. input voltage range for dc-dc converters of the front-end converter
extend their operation range. It is difficult to design a wide-operation-range PWM converter with
high efficiency. Normally, the duty cycle is designed to be as high as possible to handle the
holdup time operation, shown in Fig. 1.8. Thus, at normal conditions, the duty cycle is much
smaller. The primary side to secondary side transformer turns ratio is small, which leads to high
7
Daocheng Huang Chapter 1
primary side current, as equation (1.1) and (1.2) indicated. Both conduction loss and switching
Fig. 1.8 Duty cycle range for PWM converter with hold up requirement.
np Vin _ min
N = = D max (Full bridge) (1.1)
ns Vo
np Vin _ min
N = = D max (Half bridge) (1.2)
ns 2V o
Conceptually, PWM converters control the power flow by controlling the duty circle of
switches. When switch is on, the power flows from the source to the load. When switch is off,
8
Daocheng Huang Chapter 1
the power flow is blocked. The output filter of PWM converters is for switching frequency and
Fig. 1.9 Simplified general isolated dc/dc PWM converter block diagram
Different with PWM converter, resonant converters have quite different way to control
power flow. In general, resonant converters can be presented in a simplified block diagram form
as shown inFig. 1.10. The input can be either voltage or current source. The output sink is
implemented by rectifier circuits. The output circuit consists of either a series inductor or a
parallel capacitor with the load resistance in order to give current sink or voltage sink,
respectively. The basic resonant cell consists of frequency selective network whose function is to
transfer the energy from the source to the load. In other words, it works like a band-pass filter.
Fig. 1.10 Simplified general isolated dc/dc resonant converter block diagram
As shown in Fig. 1.11, resonant converter controls the power flow by adjusting the switching
frequency. When the switching frequency is around the resonant frequency, most of the input
9
Daocheng Huang Chapter 1
power pass through the band-pass filter. When the switching frequency deviates from the
resonant frequency, the input power is attenuated by the filter, thus, only part of it flow to the
A good band-pass filter is desirable for efficient energy delivery. Here, good band-pass filter
means the least circulating energy in the converter. Nevertheless, which resonant cell contributes
Series resonant converter (SRC) is one of the basic resonant converters[A.31]-[A.36]. The
schematic of series resonant converter is Fig. 1.12. The voltage gain curves of the SRC is shown
in Fig. 1.13. The benefits are ZVS achievable above resonant frequency, ZCS achievable below
10
Daocheng Huang Chapter 1
resonant frequency. The operating region is on the right side of resonant frequency owing to
Series resonant frequency is most efficient point. From the gain curves, we can see the gain
equals one at resonant frequency. The total energy from the source is delivered to the load.
However, the resonant frequency is the boundary of ZVS and ZCS region. It is very risky to
operate at this point. Due to the holdup time requirement, the operation point is far away from
resonant point at nominal input voltage (Vin=400V), and the voltage gain is much smaller than
11
Daocheng Huang Chapter 1
one. Meanwhile, the turn-off current increases significantly due to large phase shift between
excitation voltage and current of the resonant tank. The switching loss will be high.
Light load regulation is bad for SRC. It can be seen from the operating region that at light
load, the switching frequency needs to increase to a very high value to keep the output voltage
SRC is not a good candidate for front end DC-DC converter. The major problems are: light
load regulation, high circulating energy and turn off current at nominal input voltage condition.
of parallel resonant converter is Fig. 1.14. The voltage gain curves of the SRC is shown in Fig.
1.15. The operating region of the PRC is shown inFig. 1.15as shaded area. Similar to SRC, the
operating region is also designed on the right hand side of resonant frequency to achieve ZVS.
Compared with SRC, the voltage gain of PRC can be larger than one. That means PRC can
boost voltage. Meanwhile, the operating region of PRC is much narrower. At light load, the
frequency doesn't need to change too much to keep output voltage regulated.
12
Daocheng Huang Chapter 1
However, the circulating energy is very high for PRC, even at light load. For PRC, since
the load is in parallel with the resonant capacitor, even at a no-load condition the input still sees a
pretty small impedance of the series resonant tank. This will induce pretty high circulating
The major problems of PRC are: high circulating energy, high turn off current at high input
voltage condition.
In sum, to deal with a wide input voltage range, all these traditional resonant converters
encounter some problems. To achieve higher efficiency, other resonant topologies should be
considered.
1.3.2 Advantages of LLC Resonant Converter (LLC) with Hold-up Time Requirement
LLC resonant converters (LLC) is drawn a lot of attention since 1990 [A.41]-[A.48].The
half bridge LLC resonant converter is illustrated in Fig. 1.16. The voltage gain of the LLC
13
Daocheng Huang Chapter 1
resonant converter is drawn in Fig. 1.17. When switching frequency lower than resonant
frequency (fs<fo), the voltage gain is more like parallel resonant converter. When switching
frequency higher than resonant frequency (fs>fo), the voltage gain is more like series resonant
converter. With variable frequency control, the voltage gain of LLC resonant converter can be
controlled as boost mode or buck mode. Based on the combination of two resonant frequencies,
LLC resonant converter has more advantages than previous introduced converters.
14
Daocheng Huang Chapter 1
ZVS is achievable from no load to full load. With the help of parallel resonant frequency,
LLC can operate around series resonant frequency without the risk falling into ZCS region. In
addition, voltage gains of different Q converge at this point. Thus, the LLC would not change
frequency too much as load changes. The voltage second on Lm, which determines the turnoff
current, is relatively constant. And this current independent of load helps primary devices charge
and discharge junction capacitance to achieve ZVS. In other words, ZVS is independent of load.
Low turnoff loss is achievable for primary devices due to low turnoff current. The turnoff
ZCS for synchronous rectifier (SR) is naturally achieved if it operates at or below series
resonant frequency. When switching period equals the series resonant period, the primary current
(iLr) resonances to touch magnetizing current (iLm). Meanwhile, secondary side current reaches
zero. When switching period becomes larger, the discontinuous period of secondary current
extends.
15
Daocheng Huang Chapter 1
Magnetic integration is easily achieved for LLC. Because of soft-switching for primary and
secondary devices, LLC can increase switching frequency to push power density. On the other
hand, high switching frequency introduces small magnetic component, which makes them easy
integration. For LLC, Lr could be the leakage inductance of transformer, while Lm is the
magnetizing inductance, as shown in Fig. 1.16. Naturally, LLC has the potential to integrate all
the magnetic components into transformer, which continue push power density.
The holdup time extension capability is accomplished without sacrificing the efficiency
under the nominal operating condition. As mentioned before, series resonant frequency is the
optimal operation point for LLC. By reducing the LLC switching frequency, high voltage gain is
achievable, which is desired for the holdup time operation. Therefore, the LLC resonant
converter has been a very popular topology for the front-end power supplies in computing
Soft-switching diminish most of switching loss, thus, LLC can reach high efficiency and be
easy to push high frequency. High frequency and easy integration structure give LLC the
potential to reach high power density. Fig. 1.19 shows the volume and efficiency comparison of
two commercial front-end products. It is obvious that the front-end converter with LLC has
better power density and efficiency than the one with PWM converter.
For the benefits of LLC resonant converter as mentioned above, firstly it is adapted by flat-
panel display. Then, telecom quickly accepts it as main stream solution. Right now, LLC
gradually takes the markets of LED lighting, server and datacenter, etc.
16
Daocheng Huang Chapter 1
Fig. 1.19 Commercial products comparison with LLC DC/DC and PWM DC/DC
17
Daocheng Huang Chapter 1
However, there are many issues for the LLC resonant converter to deal with, like start-up,
short-circuit protection, SR driving method, EMI noise reduction and magnetic design, etc.
The first issue is start-up process. Although LLC has parallel resonant frequency to help
achieve holdup requirement, the voltage gain above resonant frequency is very flat due to the
During the soft start-up process, the switching frequency needs to be pushed to a high value
(fs>f0), and then decreased step by step, in order to minimize the voltage and current stress in the
18
Daocheng Huang Chapter 1
If the start-up frequency (fmax) is not high enough, there will be large voltage and current
stress in the resonant tank at the start-up moment. Fig. 1.22shows the experimental test of [A.49]
where the voltage and current stress is large in the resonant tank if starting-up with 1.6 times of
resonant frequency.
For isolated dc/dc converter, synchronous rectifier is necessary to improve the efficiency of
DC/DC converter. The SR driving signals for PWM dc/dc converter are very easy to get from
primary side device signal. Take phase shift full bridge converter as example[A.56], the circuit is
19
Daocheng Huang Chapter 1
shown in Fig. 1.23. The driving signal of SR2 is the same as SA, and the driving signal of SR1 is
LLC resonant converter is quite different with PWM converter for SR driving scheme. The
driving signal of primary side and secondary side devices are not in phase, as shown in Fig. 1.24.
iLr
iLm
VgsS1
VgsS2
phase difference phase difference
Fig. 1.24 Desired SR gate driving signals in different switching frequency regions
20
Daocheng Huang Chapter 1
When fs<f0, the SR should be turned off earlier than the main switch. Otherwise, the SR
would conduct circulating energy, namely a reverse current from the load to the source, thus
causing a greater increase in the RMS currents and turn-off current, and causing efficiency to
deteriorate dramatically. When fs>f0, the SR should be turned off a bit later than the main switch.
Otherwise, the sharply decreased current would go through the paralleled body diode, resulting
in a serious reverse recovery. Therefore, the driving signals of SRs and main switches cannot
derive from the same PWM signal for control of the conduction times as those in the isolated
PWM converters.
driving signal. The method is precise, but due to the large current on the secondary side, it
requires a large size current transformer and it presents a lower efficiency due to the extra
An alternative solution [A.58] is sensing current through the transformer’s primary side
winding. The primary side current is a precise replica of the secondary side current. Although a
21
Daocheng Huang Chapter 1
smaller loss could be achieved when compared to the secondary side current sensing, three
magnetic components are needed, losing the integration of leakage, magnetizing inductors and
d’ iSR
Vth_off
Lpackage ideal Vds
sensed Vd’s’
Vth_on
SR duty loss
VgsSR Actual ton
s’
A promising driving method is based on the SR drain to source voltage. The sensed SR Vds
is processed by the control circuits as [A.59]. However, the accuracy of this driving scheme is
highly affected by the SR package [A.60]. Due to the inevitable package inductance, the sensed
22
Daocheng Huang Chapter 1
terminal drain to source voltage of the SR is actually the sum of the MOSFET’s on status
resistive voltage drop and the package inductive voltage drop. Fig. 1.27shows that the sensed Vd's'
of the SR terminal deviates greatly from the purely resistive voltage drop Vds of the MOSFET.
Thus, the actual SR drive signal VgsSR is significantly shorter than the expected value.
Therefore, an accurate SR driving scheme under high frequency is required, which can
control the SR gate driving signal in the whole switching frequency regions with simple
implementation. This method should not increase the volume of whole system too.
Isolated high output current dc/dc converter may suffer very high conduction loss at
High conduction loss of secondary windings and SR devices is the first issue for low-voltage
high-current applications. To deal with this issue, a paralleled winding structure with paralleled
SR devices is a common practice. However, this structure is not good enough. The conventional
circuit schematic of the transformer and SR structure is shown in Fig. 1.28. The conventional
planar transformer and the secondary side structure are depicted in Fig. 1.29.
The current sharing among secondary windings and SR devices becomes an issue for this
parallel structure. The current distribution through secondary side is determined by many aspects,
including the resistance and leakage inductance of windings, the package inductance and
resistance of SR devices, the trace and connection inductance and resistance, etc. Thus, it is hard
23
Daocheng Huang Chapter 1
High termination losses is the another issue. Due to the proximity effect and skin effect, the
currents in adjacent terminals with opposite directions attract each other. Thus, very high losses
and hot spots are generated. This termination loss deteriorates efficiency significantly. For the
conventional design, all SR devices are placed on the motherboard. Physically speaking, a large
loop of the secondary side rectifiers is inevitable. Consequently, a large distribution loss will be
24
Daocheng Huang Chapter 1
symmetrical layout for each SR. Hence, current-sharing of the SR is a severe problem.
Thus, how to improve the efficiency and power density of high step-down dc/dc converter is
a key issue.
In EMC standards, such as FCC part 15 in the United States and EN55022, CISPR 22 in
Europe, the conducted EMI noise emissions of devices are limited. It is required to meet the EMI
Fig. 1.30 CM noise spectrum comparison of PWM and LLC resonant converters.
Because of the bulk capacitor between PFC and dc-dc converter, only common mode noise
of dc-dc converter will influence the grid and EMI filter. The measured common mode EMI
noise spectrum of LLC resonant converters is shown in Fig. 1.30. Compare with PWM converter,
it is a stringent challenge to reduce the EMI noise due to the EMI standard requirement [A.61].
25
Daocheng Huang Chapter 1
Since LLC resonant converter has so many issues, how to deal those issues but still keep the
merits of LLC is a challenge. Some issues come from the fundamental characteristics of LLC
there are more than hundreds multi-element resonant topologies. Is there any resonant topology
Based on the previous sections, the merits of LLC come from the combination of two
resonant frequencies. Thus, we want to keep the characteristics below series resonant frequency
of LLC gain curves in Fig. 1.17. However, we do want to change the gain curves of LLC resonant
For the start-up and short-circuit protection issue, the fundamental reason is the flat
voltage gain above resonant frequency. To deal with this issue, the resonant topology has sharp
26
Daocheng Huang Chapter 1
For the SR driving scheme, the resonant topology, which can simply utilize primary side
The question is if there is any resonant topology having those benefits among the ocean of
resonant topologies. How to find it and how to compare them with LLC is very challenging.
The exponential rise in “Big Data” generation, processing and storage highlights the
growing demand for datacenter and cloud computing power worldwide. The subsequent task is
to maximize energy efficiency, thus saving money and natural energy resource, minimizing
27
Daocheng Huang Chapter 1
For the power semiconductor industry, the challenge is to provide efficient and high quality
power conversion from 480V 3-phase AC power entering the datacenter, all the way to 1V,
100A+ processors. Fig. 1.32 shows the typical AC distribution system structure for data center.
The ever-present trend for datacenter distributed power systems is the pursuit of higher
efficiency and power density. Existing solutions within the AC-DC conversion-system topology
The answer may be to look instead to a very different AC-DC structure, based on new
approaches rather than merely incremental ones. Using high-voltage DC for power transmission,
in conjunction with new conversion approaches, offers tangible and significant benefits for both
sourcing options and system end-to-end performance. Recently, Intel proposed a 400 Vdc direct-
28
Daocheng Huang Chapter 1
distribution bus for data center applications in order to reduce the number of power conversion
stages and the power loss in the power distribution path, as shown in Fig. 1.33. By eliminating an
AC uninterruptible power supply (UPS) and a transformer in the power distribution unit (PDU),
the overall efficiency can be improved. In fact, some work from France Telecom and China
Mobile estimate that between 8% and 10% across the board can be saved by going to DC
distribution[A.7]-[A.8], [A.65]-[A.67].
Continue pushing whole system efficiency, one effective way is to reduce the regulated
DC/DC stage. For new DC distribution system, the holdup requirement is not valid due to the
battery connecting to 380V bus. IBM supercomputer utilizes the DC system illustrated in Fig.
1.34. The efficiency of each module is also given in each box. There is only one regulation stage:
PRM (Pre-Regulated Module) regulator. Bus converter and VTM (Voltage Transformer Module)
are both unregulated DC/DC converter. The efficiency of the power train can be as high as 87%.
Another possible power train structure is shown in Fig. 1.35. The DC/DC converter from
400V to 12V only needs to deal with small ripple on the bus, which can be easily deal with next
regulated stage (VR). It is obvious that two regulated stages are less efficient than one regulated
29
Daocheng Huang Chapter 1
Thus, how to improve the efficiency and power density of high ratio step-down DCX is one
Compared with regulated LLC-D2D, LLC-DCX has better performance and less issues
Firstly, its switching frequency is fixed exactly at the resonant frequency point (fs=f0) to
achieve the best efficiency[A.68]. Meanwhile, the SR current is in phase with primary side
driving signal just like PWM converter. It is very easy to achieve SR driving by utilizing primary
side driving signal. Due to new system architecture, LLC-DCX do not need to worry about start-
Thus, start-up, short-circuit protection and SR driving are not issues for LLC-DCX
anymore.
30
Daocheng Huang Chapter 1
Usually, large Lr is designed for LLC-D2D to help achieve holdup time and regulation
requirement, while LLC-DCX does not have that. Mostly large Lr needs extra inductor in series
with leakage inductance of transformer, which increases the volume and loss of whole system.
For LLC-DCX, Lr is only the leakage inductance of transformer, and can be as small as possible.
LLC-DCX has potential to be high efficiency and high power density. For high efficiency
and easy magnetic integration, LLC-DCX could operate at high switching frequency. Meanwhile,
the high frequency transformer design and EMI are still issues for LLC-DCX.
High performance active devices have been the first force to increase power density to meet
the requirements of modern systems including datacenter. Silicon devices have dominated for
power management since the late 1950s. However, due to continuous device optimization and
31
Daocheng Huang Chapter 1
improvements in the production process, material properties of Si are increasingly becoming the
limiting factor.
Fig. 1.37 Specific on-resistance versus breakdown voltage for GaN and Si
In recent years, the GaN HEMT has emerged as a promising device for high frequency, high
efficiency, high density power conversion due to a better figure of merit than comparable Si and
SiC transistors [A.69]-[A.71]. A progressively larger number of GaN devices have been
manufactured for in field applications ranging from low power voltage regulators to high power
pushed up to several MHz to both reduce passive components size and increase power density.
Taking into account the challenges raised during the review of the existing literature on the
LLC resonant converters, several issues have been addressed in this dissertation.
32
Daocheng Huang Chapter 1
Chapter 1:
The advantages of LLC resonant converter over PWM converter and traditional resonant
converters are presented, especially under hold up time requirement. However, LLC has its own
issues, like startup, short-circuit protection, SR driving, transformer design and EMI
performance. Multi-element resonant converters are one possible way to deal with them.
Meanwhile, with the new system architecture of datacenter, there is opportunity to use
unregulated LLC, which has less issues and better performance than regulated LLC resonant
converter. This new structure and emerging GaN HEMT promote the requirement of high
frequency high efficiency transformer design. To be more advanced, passive integration for
Chapter 2:
One effective way to solve the fundamental issues of LLC resonant converter is to find
The resonant tank acts like band-pass filter in resonant converters. The four type basic
resonant cells are studied. A synthesis of resonant topology based on basic resonant cells is
proposed. Every two basic resonant cells are combined to form a new resonant cell. Three three-
converters helping limit the inrush current during startup or short-circuit protection period.Eight
LLC-like resonant converters with notch filter are discovered based on previous synthesis.
33
Daocheng Huang Chapter 1
tank for 3rd harmonics band-pass filter. Twenty five-element resonant converters with 3rd
Chapter 3:
Lots of LLC-like resonant converters are discovered based on the method in chapter 2. How
to evaluate each topology still remains an issue. To find out if new resonant topologies have
To utilize state-plane for evaluation, traditional normalization factors are not good enough.
The new normalization factors are proposed based on the apparent power of converter. Utilizing
the state-plane with new normalization factors, the apparent power, voltage and current stresses
Current limit capability, SR driving scheme, magnetic integration and EMI noise are very
important to resonant converters. All of them are taken into account to evaluate the performance
of resonant converters.
Based on the pros and cons of each LLC-like resonant converter, several possible
Chapter 4:
To deal the high output current conduction loss, the resonant topology can hardly help. The
circuit topology can help. To alleviate the heavy output current, the matrix transformer instead of
the traditional transformer is proposed. Matrix transformer can help split transformer secondary
current to reduce conduction loss. With the matrix transformer winding structure, series at
34
Daocheng Huang Chapter 1
primary side and parallel at secondary side, the current sharing problem among windings and SR
The price is the multiple cores of matrix transformer. With the concept of flux cancellation,
the number of core reduces into half. In other words, the core loss and core volume are greatly
to eliminate termination loss. After that, the tradeoff of termination loss and interleaving is
Chapter 5:
For better power density, passive integration is necessary. However, capacitance integration
is risky due to life time constraint. An evaluation criteria is proposed to determine which
components integrated in the system based on lowest voltage and current stress.
A passive integration method is given to integrate all the magnetic components and
Chapter 6:
35
Daocheng Huang Chapter 2
Converters
In this chapter, a general and systematic method to explore the characteristics of multi-
resonant cells. The resonant converter inherits the characteristics of parental resonant cells. LLC
resonant converter is one of the most popular topologies in DC/DC converters. The LLC-like
resonant converters are found by the synthesis of basic resonant cells. Furthermore, the LLC-like
The input DC voltage or DC current source is converted into square waveform by primary
switches. The output sink is implemented by rectifier circuits. The output circuit consists of
either a series inductor or a parallel capacitor with the load resistance in order to give current
The basic resonant cell consists of frequency selective network whose function is to transfer
the energy from the source to the load, in other words, band-pass filter. The passing-through
energy is controlled by changing the switching frequency. The band-pass filter characteristic of
each resonant tank could be represented by its voltage transfer functions [B.1], [B.2].
36
Daocheng Huang Chapter 2
Fig. 2.1Simple Block diagram for the basic concept of resonant converter
Most of dc-dc applications are voltage source, like front-end dc-dc converters. Thus, the
voltage source is taken into account in the following analysis. The similar concept can also be
37
Daocheng Huang Chapter 2
When the operation point at resonant frequency (fo, in Fig. 2.1), the input voltage (Vac) is in
phase with input current (iin). The output power reaches its maximum value if input power is
fixed. All of the input power is directly delivered to the load. When operation below fo, the
voltage is leading the current, so the tank is capacitive. The up slop of voltage gain indicate ZCS
operation, as shown in Fig. 2.2.When operation above fo, the current is leading the voltage, so the
tank is inductive. The down slop of voltage gain indicates ZVS operation.
Two-element resonant tanks are basic resonant cells of multi-element resonant converters.
For two energy storage elements, there are totally eight resonant tank configurations as shown in
Fig. 2.3. Tank A, B, C and D are suitable for voltage source, and Tank E, F, G and H are suitable
for current source. Here, not “suitable” means no regulation capability (like Tank E to voltage
38
Daocheng Huang Chapter 2
Tank A is series resonant tank, which is the resonant tank of series resonant converter (SRC).
It behaves like band-pass filter. The resonant frequency in Fig. 2.4 (a) is named series resonant
frequency (SRF). When the frequency of input energy is the same as SRF, the whole energy will
pass through it, while the energy of other frequencies is attenuated. However, this band-pass
filter is not good at light load. The voltage gain becomes flat. Hence, a very high switching
The resonant frequency in Fig. 2.4 (b) is named parallel resonant frequency 1 (PRF1). It is
not good band-pass filter either. The high frequency input energy will pass through it, but low
frequency energy will be blocked. Thus, it performs more like high-pass filter.
The resonant frequency in Fig. 2.4 (c) is named parallel resonant frequency 2 (PRF2). It is
the resonant tank of parallel resonant converter (PRC). It is not good band-pass filter either. The
low frequency input energy will pass through it, but high frequency energy will be blocked. Thus,
Both of two PRFs have high gains at light load around resonant frequency. Steep slope close
The resonant frequency in Fig. 2.4 (d) is named notch resonant frequency (NRF). This tank
is quite different from previous tanks. It behaves like a band-stop filter. When the frequency of
input energy is the same as NRF, the tank impedance is infinite high, the whole energy will be
blocked. Meanwhile, the energy of high order harmonics pass through the whole tank. Thus,
All of basic resonant cells are only have one resonant frequency. The resonant frequency is
the most efficient point for the resonant tank except band-stop filter, because all the fundamental
39
Daocheng Huang Chapter 2
of input power is delivered to the load. Otherwise, part of it is attenuated by the tank. However,
they cannot operate at resonant frequency in fear of falling into different soft-switching region,
like from ZVS into ZCS or from ZCS into ZCS, which is detrimental to devices.
40
Daocheng Huang Chapter 2
From the discussion above, two-elements resonant converters have their inherent limitations.
Because each resonant frequency has its own characteristics, the synthesis of two or more
LCC resonant converter (LCC) and LLC resonant converter (LLC) are very good examples
LCC resonant converter (LCC) is a popular resonant converter in many applications. It is the
combination of series resonant converter (tank A) and parallel resonant converter (tank C). SRF
is at the left side of PRF2, in other words, ZCS region of PRC. Around SRF, most region is ZCS
region, which is not preferred. Series resonant frequency (SRF) (black dot in Fig. 2.5 (a)) helps
in operation; however, the operation region (shadow in Fig. 2.5 (a)) is away from SRF. Thus,
LCC is still dominated by parallel resonant frequency (PRF), and have similar pros and cons as
41
Daocheng Huang Chapter 2
LLC is the combination of tank A and tank B. It is different from LCC due to the different
order of two resonant frequencies. PRF2 is at the left side of SRF, in other words, the ZCS
region of SRF. PRF2 improves part of this region into ZVS region. Thus, it is safe to operate
around SRF, where is the optimal point. However, the right side of SRF is still flat [B.3]-[B.10].
The synthesis of SRF and PRF1 generates many merits : (1) ZVS capability for zero to full
load range; (2) low turn off current for primary side switches; (3) Zero-current-switching (ZCS)
for synchronous rectifier devices; (4) voltage gain boost capability without deterioration of
Three-element resonant converters have more resonant frequencies than two-element. The
synthesis of resonant frequencies could provide extra benefits to the resonant converter.
However, the synthesis should be the right types and the right order of resonant frequencies to
42
Daocheng Huang Chapter 2
As mentioned before, LLC has many advantages due to the synthesis of resonant
All the three-element resonant topology networks are given in Fig. 2.7 [B.11]. The topology
networks 15, 16, 17 are degraded to two-elements if the blocks replaced by an inductor or
capacitor.
Replacing each block of networks with an inductor or capacitor, 36 topology candidates are
If the input source types are taken into account, there are some tanks are not suitable. Firstly,
if one or more elements are clamped to input voltage source, the whole resonant tank will be
degraded to less order system. Secondly, capacitors cannot be in parallel with voltage source.
Based on these two criteria, there are only 13 topologies left, shown in Fig. 2.9.
43
Daocheng Huang Chapter 2
44
Daocheng Huang Chapter 2
The tanks in Fig. 2.9 are classified by combination of the resonant frequencies defined in
section 2.1.1.
From Fig. 2.10 to Fig. 2.14, the dot lines show the boundaries of ZVS and ZCS regions.
As shown in Fig. 2.10, Tank D and Tank H1 are the synthesis of SRF and NRF. Thus, this
group has similar characteristics like SRC. NRF sharps flat voltage gains above SRF, so ZVS
However, resonant frequencies are the boundaries of ZVS and ZCS regions. Operation at
As shown in Fig. 2.11, Tank C and Tank G1 are the synthesis of SRF and NRF. Thus, this
group has similar characteristics like SRC. In this group, NRF sharps flat voltage gains below
45
Daocheng Huang Chapter 2
As shown in Fig. 2.12, Tank K is the synthesis of PRF and NRF. Thus, this group has similar
characteristics like PRC. NRF sharps voltage gains above PRF, so ZVS region of PRC is
improved. However, the ZVS region of PRC is sharp before. Thus, the improvement is limited.
Meanwhile, PRF and Notch filter are the boundaries of ZVS and ZCS regions. Operation at
46
Daocheng Huang Chapter 2
As shown in Fig. 2.13, Tank L and Tank O are the synthesis of PRF and NRF. Thus, this
group has similar characteristics like PRC. Similarly, NRF sharps voltage gains below PRF, so
ZCS region of PRC is improved. Operation at resonant frequency is still not achievable in this
As shown in Fig. 2.14, Tank H, Tank Z and Tank X are the synthesis of SRF and PRF. Thus,
this group has both characteristics of SRC and PRC.PRF locates at higher frequency and SRF at
47
Daocheng Huang Chapter 2
lower frequency. Tank H in this group is the resonant tank of LCC resonant converter. The
typical voltage gain curves are very similar as LCC resonant converter. Thus, this group is
As shown in Fig. 2.15, Tank G, Tank W and Tank U are the synthesis of SRF and PRF, like
LCC. The difference is PRF locates at lower frequency and SRF at higher frequency. Tank G in
this group is the resonant tank of LLC resonant converter. The typical voltage gain curves are
very similar as LLC resonant converter. In this group, operation at resonant frequency is durable
due to the help of PRF. The resonant converter in this group can operate around series resonant
frequency without the concern falling into the ZCS region under given load condition.
Furthermore, they have the similar merits of LLC, like low loss at nominal conditions, ZVS for
whole load range, ZCS for output rectifier, etc. They can also achieve good efficiency at high
input voltage, where the front-end dc-dc works for 99% time, with wide input range. Thus, this
48
Daocheng Huang Chapter 2
For the inherent problem from SRF, the startup and short-circuit protection of LLC are still
Fig. 2.16 shows the DC characteristic of the LLC resonant converter. Normally, the LLC
operates near the resonant frequency point (fs=f0) to keep the best efficiency. During the hold-up
time operation, the input voltage decreases while the output voltage should stay constant, thus
the switching frequency decreases (fs<f0) to boost the voltage-gain. Under the soft start-up
condition, the output voltage needs be built up from zero to the steady-state value, in order to
prevent from entering the zero-current-switching (ZCS) zone, the LLC should work in above
2.0
hold-up
Voltage gain nVo/Vin
1.5
normal operation point
1
0.01
0.2
0.3
ZVS 0.6
0.5
ZCS 1.0
3.0 start-up
Q=20
vo=0
0
0 1.0 2.0 3.0 4.0
f n=f s/f 0
However, as shown in Fig. 2.17, if the start-up switching frequency (fs) is not high enough,
large voltage and current stress can be observed at the start-up moment [A.49]-[A.54].
49
Daocheng Huang Chapter 2
Vcr
full-load steady state
fmax=1.5f0
(a) Voltage and current stress of resonant tank during soft start-up
50
Daocheng Huang Chapter 2
iLr
Vcr
VO
fmax=5f0 full-load steady state
(a) Voltage and current stress of resonant tank during soft start-up
51
Daocheng Huang Chapter 2
Otherwise, as shown in Fig. 2.18, if the LLC starts up with a very higher, this is about 5
times of normal operation frequency. At the beginning, the voltage and current stress will be not
large. However, during the soft start-up process, if fs decreases too quickly, large voltage and
current stress can still happen, which will trigger the over-current-protection. As a result, fs will
increase a bit to limit the stress, and then decreases smoothly to finish the soft start process. If fs
decreases slowly, the stress will stay small, but the output voltage will build up slowly, which
Thus, if frequency control is applied start-up process, the operation frequency of LLC
resonant converter should be very high to attenuate the voltage and current stress at the
beginning of start-up. Even start up at high frequency, the high voltage and current stresses still
high.
VgsQ1
VgsQ2
VgsQ3
VgsQ4
VN
VCr
ILr
I1
I2
ILm
52
Daocheng Huang Chapter 2
Besides the frequency control, phase-shifted control can be used in full-bridge LLC to limit
the voltage and current stress during the soft start process. Fig. 2.19 shows steady state
waveforms when fs=2f0 with π/2 phase shift. For the leading leg (Q1 and Q3), it is easy to realize
ZVS, since the resonant current is large at the turn-off moment. However, for the lagging leg (Q2
and Q4), it is hard to achieve ZVS due to the lower current to charge the junction capacitors at
Based on frequency control and phase-shift control, [B.13] proposed an optimal trajectory
control for the LLC soft start-up. The resonant voltage and current stress can be limited, the
output voltage should be built up quickly and smoothly, and the ZVS of all switches can be
guaranteed.
Fig. 2.20 shows the experiment results. The start-up frequency is more than 2 times of
Vo (2V/div)
+IMAX +Ipeak
2ms 5ms/div
53
Daocheng Huang Chapter 2
However, all above control methods need very high switching frequency to attenuate the
voltage and current stress during the process of start-up. This issue comes from the inherent
As discussed in previous sections, three-element topologies have more merits than two-
elements, but three-element topologies still have their own limitations. With poor frequency
selectivity, namely, very wide bandwidth, the frequency has to be increased very high to achieve
To improve the flat voltage gain above series resonant frequency of LLC-like resonant
converters, additional resonant elements are needed to create sharp gain. The desirable voltage
gain curves are plotted in Fig. 2.21. One possible way building sharp voltage gains is making a
notch filter.
54
Daocheng Huang Chapter 2
The resonant tank with notch filter characteristic can create zero voltage gain. Conceptually,
infinite impedance can be created when frequency operates at the resonant frequency f02 of the
notch filter. As a result, if overload or even shorted output condition occurs, the current can be
limited inherently by the resonant tank characteristic. The notch filter center frequency f02 can be
One of these resonant converters is depicted in Fig. 2.22. The notch filter section is created
with Lp and Cp. The band pass filter section consists of Lp, Cr and Cp.
In general, with variable frequency control, the resonant tank input voltage is excited as a
square waveform. According to the Fourier analysis, the voltage excitation only consists of odd
harmonics. Therefore, to avoid circulating energy at nominal condition, notch filter resonant
When converter operates at f01, the notch filter represents inductive. The impedance of Cp is
much larger than Lp. The major part of primary side current flows through Lp, not Cp. The current
55
Daocheng Huang Chapter 2
for classification and selection can save a lot effort and energy to find desired topologies.
All four-element networks are listed in [B.14], [B.15], as shown in Fig. 2.23. Each square
block represents one energy storage element. The networks in the dot line pane in Fig. 2.23 are
not suitable for voltage source, for they cannot regulate voltage.
Fig. 2.24 shows the relationship between resonant frequency types and topology networks.
Each square block in Fig. 2.24 represents one or more energy storage elements. The rectangle
block indicates input source or output sink or other energy storage elements. If the resonant
characteristics shown in Fig. 2.24 are wanted, the network below gain curves should be part of
resonant tanks.
As discussed before, series resonant frequency (SRF) is needed to achieve low switching
loss and low circulating energy at nominal conditions where the operation point is close to it.
Parallel resonant frequency is required for wide range voltage regulation. With the combination
of these two resonant frequencies, zero-current switching (ZCS) is achieved for the output
rectifiers, and no reverse recovery appears. A notch filter is also needed for startup and short-
circuits protection. Thus, the candidate topology should include PRF, SRF and NRF. The
56
Daocheng Huang Chapter 2
57
Daocheng Huang Chapter 2
58
Daocheng Huang Chapter 2
Fig. 2.25 shows the topology networks including network 2 structure based on Fig. 2.23 and
Fig. 2.26 Four-element resonant topology networks including Network 2(SRC) and Network 1(PRF)
Fig. 2.26 shows the topology networks including network 1 and network 2 structures based
Fig. 2.27 Four-element resonant topology networks including Network 2(SRC), Network 1(PRF) and
Network 3 or 4 (NRF)
59
Daocheng Huang Chapter 2
Fig. 2.27 shows the topology networks including network 1, network 2 and network 3 (or
network 4) structures based on Fig. 2.26 and Fig. 2.24. The number is 7.
In topology network shown in Fig. 2.27,, each energy storage element can be replaced with
inductor or capacitor. The result is shown in Fig. 2.28,, ignoring which are not su
suitable for
voltage source.
Network 3 or 4 (NRF)
60
Daocheng Huang Chapter 2
Three different resonant frequencies should be arranged in order. Operation point is near
series resonant frequency (SRF) to achieve low switching loss and low circulating energy.
Parallel resonant frequency (PRF) should locate at lower frequency for wide range voltage
regulation. Notch resonant frequency (NRF) should be placed at higher frequency for start-up
and short-circuit protection. Thus, the order of resonant frequencies is PRF, SRF and NRF from
61
Daocheng Huang Chapter 2
low frequency to high frequency (shown in Fig. 2.29). Eight topologies are gotten based on this
rule shown in Fig. 2.29. We can see that they also can be deduced from three-element LLC-like
resonant converters.
Similarly, the synthesis method based on resonant frequencies can be utilized in three, four,
2.6 LLC-like Resonant Converters with Notch Filter and Two Band-pass
Filters
With leakage inductance Lr, a second band pass filter is created. A 5-elements resonant tank
is given as an example, shown in Fig. 2.30. The second band pass filter is designed at the three
times of the nominal frequency. The third order harmonics energy of primary side can be
delivered through this band pass filter as shown in Fig. 2.31. Obviously, the power delivery is
more efficient.
62
Daocheng Huang Chapter 2
63
Daocheng Huang Chapter 2
Fig. 2.33Five element resonant tank cell based on LLC with notch filter and 3rd harmonics band filter
64
Daocheng Huang Chapter 2
However, the number of five-element resonant topologies is even much more than four-
element resonant converters. A same systematic way is used for searching resonant topologies
Based on the searching results of previous section, one more inductor should be added into
resonant tanks in Fig. 2.29. Fig. 2.33 shows the searching results of 5-element resonant converters
Each resonant frequency expression is shown in equation (3.1), (3.2) and (3.3) for the
When switching frequency is very low, the effect of Cp is weak, Lr and Lp are in series to
resonance with Cr. Lp resonances with Cp to get notch filter. If switching frequency reach very
high, the impedance of Lp is very high. Thus, only Cr and Cp are in series to resonance with Lr.
= ≈ + (2.1)
= (2.2)
= ≈ (2.3)
Fig. 2.34shows the waveforms of under full load condition. The tank current is more like
square waveform which combines fundamental and 3rd harmonics. Fig. 2.35 shows the tank
waveforms under short-circuit condition. The output current is limited to less than half load.
65
Daocheng Huang Chapter 2
Fig. 2.34 Experimental results for 5-element resonant converters under full load
Fig. 2.35 Experimental results of 5-element resonant converters under short-circuit condition
2.7 Conclusion
A systematic method to classify and select resonant tanks is proposed. Three-element, four-
element and five-element resonant tanks are analyzed based on the proposed principle.
66
Daocheng Huang Chapter 3
resonant converters. State-plane analysis with new normalization is proposed to evaluate the
resonant converter performance. Based on it, the voltage stress, current stresses and apparent
power of resonant converters are easy to compare. This method can help select suitable circuit
topology for certain application. Meanwhile, it also can help resonant converters’ design. The
important performance factors, like start-up, short-circuit protection, SR driving and EMI, are
3.1 Introduction
There are still many candidate topologies which fits required characteristics based on
previous selection methodology. It is not enough to choose resonant topologies based on the
combination of resonant frequencies. Thus, several evaluation methods are proposed. First, the
current stress of primary devices is major concern, because it will determine the conduction of
primary side. Secondly, the voltage stress on resonant capacitor is still important due to the life
time of capacitor. Then, the integration is taken into consideration, which includes the ease of
magnetic integration and the impacts of integration, including synchronous rectifier drive, EMI
67
Daocheng Huang Chapter 3
In order to determine the optimal trajectory under transition conditions, the state-plane
analysis is introduced. In [C.1]-[C.3], the state plane is presented to analyze the SRC steady state
and transient behavior. In this section, we extend this approach to the LLC resonant converter.
To simplify the analysis, it is assumed that the output capacitor is large enough that the
output voltage (Vo) can be approximated to be constant. A second assumption is that the circuit
losses, including the resonant tank, switch, and filter losses, are negligible.
Under these conditions, the LLC resonant converter can be viewed as a piecewise linear
• Operation stage I
+ vCr - iLr
iLrN
vCrN
(1-nVON, 0)
68
Daocheng Huang Chapter 3
The primary main switch Q1 turns on, and the resonant current flows through the secondary-
side synchronous rectifier S2. In this stage, the magnetizing inductor Lm is clamped by the output
voltage. The equivalent circuit is shown in Fig. 3.1, where the resonant capacitor Cr and the
resonant inductor Lr form the series resonant tank. The source voltage across the resonant tank is
1
v&Cr = iLr (3.1)
Cr
WherevCr and iLr are the resonant capacitor voltage and resonant inductor current. Combining
vCr − (Vin − nVo ) = ILr0 ⋅ Z0 ⋅ sin[ω0 (t −t0 )] + [VCr0 − (Vin − nVo )] ⋅ cos[ω0 (t −t0 )] (3.3)
where VCr0 and ILr0, are the initial conditions at time t=t0, Z0 = Lr Cr is the characteristic
By normalizing all voltages with the voltage factor Vin, and all currents with the current
factor Vin/Z0 in (5.3) and (5.4), the following expressions are derived:
69
Daocheng Huang Chapter 3
vCrN − (1− nVoN ) = ILr0N ⋅ sin[ω0 (t −t0 )] +[VCr0N − (1− nVoN )] ⋅ cos[ω0 (t −t0 )] (3.5)
iLrN = ILr0N ⋅ cos[ω0 (t −t0 )] −[VCr0N −(1− nVoN)] ⋅ sin[ω0 (t −t0 )] . (3.6)
[vCrN − (1− nVoN )]2 + iLrN2 = [VCr0N − (1− nVoN )]2 + ILr0N 2 , (3.7)
which behaves as a circle as shown in Fig. 5.2, whose center (1-nVoN, 0) is determined by the
source voltage across the tank, and radius depends on the initial conditions: VCr0 and ILr0.
• Operation stage II
iLrN
vCrN
(1+nVON, 0)
70
Daocheng Huang Chapter 3
In operation stage II, Q1 is on, but the current flowing through the secondary side changes its
direction as shown in Fig. 3.3. This occurs when the switching frequency is larger than the
resonant frequency (i.e. fs>f0). This stage is similar to Stage I, but the source voltage across the
[vCrN − (1+ nVoN )]2 + iLrN2 = [VCr0N − (1 + nVoN )]2 + I Lr0N 2 , (3.8)
which behaves as a circle as well, but the center changes to (1+nVoN, 0) as shown in Fig. 3.4.
iLrN
vCrN
(1, 0)
71
Daocheng Huang Chapter 3
In operation stage III, Q1 is on, but there is no current flowing through the secondary side.
This stage occurs when fs<f0. In this stage, the magnetizing inductor Lm joins the resonance. The
equivalent circuit is shown in Fig. 3.5, where Cr, Lr, and Lm form the series resonant tank. The
1
v&Cr = iLr (3.9)
Cr
1 1
i&Lr = − vCr + Vin (3.10)
Lr + Lm Lr + Lm
From (5.9) and (5.10), vCr and iLr in Stage III are given by:
VCr 0 − Vin
i Lr = I Lr 0 ⋅ cos[ω1 (t − t 0 )] − ⋅ sin[ω1 (t − t 0 )] , (3.12)
Z1
With the same normalization factors, the normalized forms of vCr and iLr are
72
Daocheng Huang Chapter 3
2 2
i i
(v CrN − 1) + LrN
2
= (V Cr 0 N − 1)2 + Lr 0 N , (3.15)
Z 0 Z1 Z 0 Z1
which behaves as an ellipse with a center (1,0) as shown in Fig. 3.6. Since Lm participates in the
resonance, the characteristic impedance Z1 becomes large (Z1>Z0). If it is normalized with the
If switch Q1 is off and Q2 turns on, there are another three operation stages:
• Operation stage IV
73
Daocheng Huang Chapter 3
iLrN
vCrN
(nVON, 0)
In operation stage IV, the primary-side main switch Q2 turns on, and the resonant current
flows through the secondary-side SR S1 as shown in Fig. 3.7. The only difference from Stage I is
the source voltage across resonant tank becomes nVo. Deriving the normalized equation for the
and thus, the circle center changes to (nVoN, 0) as shown in Fig. 3.8.
• Operation stage V
74
Daocheng Huang Chapter 3
iLrN
vCrN
(-nVON, 0)
In operation stage V, Q2 is on, but the current on the secondary side changes its direction,
flowing through S2, as shown in Fig. 3.9. This occurs when fs>f0, similar to stage II. The
• Operation stage VI
75
Daocheng Huang Chapter 3
iLrN
vCrN
(0 ,0)
In operation stage VI, Q2 is on, but there is no current flowing through the secondary side.
This stage happens when fs<f0. Like in stage III, Cr, Lr and Lm form the series resonant tank. But
the source voltage across the resonant tank changes to 0. The trajectory after normalization is:
2 2
i I
+ LrN = V Cr 0 N + Lr 0 N
2 2
v CrN , (3.18)
Z 0 Z1 Z 0 Z1
which is an ellipse as in stage III, but with a center (0, 0) shown in Fig. 3.12.
The LLC steady-state trajectory is the combination of the above six operation stages. Fig.
3.13 shows the time-domain waveforms when the LLC operates at the resonant frequency point
(fs=f0). Fig. 3.14shows the corresponding trajectory locus when mapping the normalized resonant
current iLrN and resonant voltage vCrN to the state plane. To the half-bridge LLC resonant
converter, when fs=f0, the voltage gain is one; that is, nVoN=0.5. Therefore, the two half circles of
Stage I and Stage IV have the same center (0.5, 0), which combine to form one whole circle.
76
Daocheng Huang Chapter 3
Stage I Stage IV
VgsQ1
VgsQ2
iLr
iLm
VCr
t0 t1 t2
stage I
ρ (0.5,0)
t1
ρ
t0
(t2) stage IV
When the LLC operates below the resonant frequency region (fs<f0), the magnetizing
inductor Lm participates in the resonance from times t1 to t2 and from t3 to t4, as shown in Fig.
3.15. When mapping to the state plane in Fig. 3.16, there are two partial ellipse trajectory loci of
Stage III and Stage VI, connecting two half circles of Stage I and Stage IV with split centers. In
fact, when fs<f0, the voltage gain is larger than one (i.e., nVoN>0.5), and the circle center of
77
Daocheng Huang Chapter 3
StageI is on the left of (0.5, 0), since 1-nVoN<0.5; and the circle center of Stage IV is on the right
I III IV VI
VgsQ1
VgsQ2
iLr
iLm
VCr
t0 t1 t2 t3 t4
I
III
ρ t1 t2
(0,0) ρ (1,0)
t0 t3
(t4) VI IV
In Fig. 3.17and Fig. 3.18, the LLC operates above the resonant frequency region (fs>f0). From
time t1 to t2, it operates in Stage V, which corresponds to the partial locus of the large circle,
whose center is located near (-0.5, 0). Similarly, from times t3 to t4, it operates in Stage II,
corresponding to the partial locus of another large circle whose center is located near (1.5, 0).
78
Daocheng Huang Chapter 3
I V IV II
V gsQ1
V gsQ2
iLr
iLm
VCr
t0 t1 t2 t3 t4
ρ' I
t
ρ 1
t2 V
(t4) t0
II t3 ρ
ρ'
IV
State-plane analysis was found to be a simple, yet powerful method which can clearly
portray the steady-state and transient operation of resonant converters. Also, the current stress
and voltage stress of resonant components can be observed in one single figure. Significantly the
state plane directly indicates the resonant tank energy level at which the system is operating.
79
Daocheng Huang Chapter 3
As stated above, state plane of resonant converters is good tool to analyze the performance
different topologies, there are some revisions needed. Previous state-plane analysis is based on
same normalize factors, which are Vin for voltage, Vin/Zo for current, as shown in Equation (3.19).
= I = V!"⁄Z$ (3.19)
having two or more resonant frequencies, Zo is even varied at different time period. It is hard to
Fig. 3.19 gives a comparison example of LLC and CLL resonant converters. Both converters
fs=1Mhz. The input current waveforms of two converters are the same. However, the normalized
currents do not represent the real current value due to the different characteristic impedance Zo.
80
Daocheng Huang Chapter 3
For given application, the output power Po and input voltage Vin are fixed. These two values
are independent with resonant topology. Po/Vin also means the average input current assuming no
loss in the converter. Thus, Po/Vin is an ideal normalized factor for current. Meanwhile, Vin is
the voltage normalizing factor, as shown in Equation (3.20). In the resonant converters, primary
side current represents the conduction loss of primary side devices, and the voltage cross
81
Daocheng Huang Chapter 3
capacitor express the life time of it. Thus, the state-plane of them can illustrate those key
performances.
Because of full bridge structure, the rms value of input voltage equals its average value. At
the same time, normalized input current IinNRMS equals the apparent power Pappr over output
I!" '() = I!"'() ⁄*P$ ⁄V!" + = I!"'() × V!" ⁄P$ = P-../ ⁄P$ (3.21)
Series resonant converter is taken as an example to illustrate how to utilize the new
normalization factors.
When SRC operates at resonant frequency, the tank impedance is zero. The input voltage of
resonant tank is square waveform, while the input current is sinusoidal waveform, as shown in
Fig. 3.20. Only fundamental of input voltage contributes real power, while high order harmonics
of input voltage do not. The RMS value for fundamental of input voltage is shown in Equation
(3.22).
= ∙ V3
√
_!"'() (3.22)
56778 :; ∙<=>?@A
P4 _ = 59
= √
= √
≈ 1.11 = I!" '() (3.23)
∙:; ∙<=>?@A
B B
That means 11% extra power is the minimal value for resonant converter operation.
82
Daocheng Huang Chapter 3
(b) Fourier transform of input voltage vin and input current iin
83
Daocheng Huang Chapter 3
Fig. 3.21 shows the state-plane of SRC at resonant frequency. The amplitude of normalized
current is 1.57 = 1.11 × √2, which is the minimal value of normalized current.
Design factors for LLC are shown in Equation (3.24). Ln is the ratio of magnetizing
inductance Lm and resonant inductor Lr. Q is the quality factor. Cr is the resonant capacitor. RL
Fig. 3.22(a) is the voltage gain curves of LLC, when Ln=12.5. Fig. 3.22(b) plots the steady
state-plane under new normalized factor for different Q and same Ln under full load. The voltage
and current stresses of different design can be easily compared in one coordinate system.
(a) Voltage gain curves of LLC (b) State-plane of given design @full load
84
Daocheng Huang Chapter 3
Fig. 3.23plots the steady state-plane under new normalized factor for different Q and same Ln
under full load. The voltage and current stresses of different design can be easily compared in
85
Daocheng Huang Chapter 3
Fig. 3.24depicts the voltage and current stress of LLC for different Ln and Q. Each line in Fig.
3.24means those designs sweep Q for one Ln. As Q increases, the current stress decrease, and the
voltage stress rises. The optimal design for each Ln should be around knee point of according
line. It is also known that the large the Ln is, the smaller voltage and current stresses the knee
point locates. And it is also known that the minimal apparent power of LLC is 1.11 times of
output power.
Based on chapter 4, there are three good candidates in three-element resonant topologies.
The V-I stress figure is easily drawn for other two resonant topologies.
Fig. 3.25gives the LCL resonant converter. Fig. 3.26shows the whole picture of LCL resonant
86
Daocheng Huang Chapter 3
Fig. 3.27gives the CLL resonant converter. Fig. 3.28shows the whole picture of LCL resonant
87
Daocheng Huang Chapter 3
88
Daocheng Huang Chapter 3
Fig. 3.29 gives the V-I stress comparison of all three 3-element resonant converters. It is
obvious that LCL resonant converter have larger voltage and current stress than CLL and LLC
One design for each topology is chosen to depict in state-plane based on proposed
normalized factor in Fig. 3.30. Each design is one dot shown in Fig. 3.29.
Startup and short-circuit protection are not good in LLC resonant converter. Fig. 3.31gives
one example of LLC resonant converter startup procedure. The LLC resonant converter starts up
at one higher frequency than resonant frequency, where current stress depends on current gain.
The output voltage gradually increases at this frequency. When it reaches one preset voltage, the
89
Daocheng Huang Chapter 3
switching frequency slowly decrease to resonant frequency. The whole start up progress is
The key problem in LLC startup is the current stress is very high.
Fig. 3.32presents the voltage gain and current gain curves comparison of three-element
resonant converters. It is clear that CLL resonant converter has the same problem as LLC.
However, the LCL resonant converter is quite different. The startup current of LCL resonant
90
Daocheng Huang Chapter 3
The accurate synchronous rectifier drive is very critical in high output application for
resonant converters. Utilizing primary side current of transformer is very easy way to get precise
SR drive signal.
The LLC resonant converter normally integrates the magnetizing inductance into the
transformer. The magnetizing current will give phase shift between primary and secondary
current. That is the reason LLC resonant converter cannot use primary side current for SR drive.
In another side, LLC can use primary side current without integrate Lm and Lr, which cause
91
Daocheng Huang Chapter 3
CLL and LCL resonant converter is different as shown in Fig. 3.33. Both of them can
Fig. 3.33SR drive Comparison of LLC, CLL & LCL Resonant Converters
92
Daocheng Huang Chapter 3
LLC resonant converter has high common mode noise at and beyond switching frequency.
One example is shown in Fig. 3.34compared with EMI standard. The common mode noise path is
93
Daocheng Huang Chapter 3
Fig. 3.36CM noise spectrum of LLC, CLL & LCL Resonant Converters
Compare with LLC, CLL has lower CM noise at very high frequency spectrum due to soft
voltage edge. The LCL resonant converter has very different EMI characteristics. The voltage
cross transformer is like sinusoidal, thus, there is high peak at switching frequency but very low
for higher frequencies. Fig. 3.36 shows the CM noise spectrum comparison.
94
Daocheng Huang Chapter 3
Fig. 3.37CM noise spectrum of LLC, CLL & LCL Resonant Converters
3.5 Conclusion
95
Daocheng Huang Chapter 4
Application
In this chapter, LLC resonant converter with matrix transformer is introduced. Flux
cancellation method is utilized to reduce core size and loss. Synchronous Rectifier (SR) devices
and output capacitors are integrated into secondary windings to eliminate termination related
4.1 Introduction
As mentioned before, LLC type resonant converters are excel in both of efficiency and
power density [D.1]-[D.8]. Firstly, it has ZVS capability for zero to full load range. Then, low
turn off current is achievable for primary side switches. At the same time, synchronous rectifier
(SR) devices are zero-current-switching (ZCS). At the end, it gets voltage gain boost capability
without efficiency deterioration at normal condition, suitable for application with hold-up time
requirement. In comparison with soft switching PWM converters, LLC resonant converters can
achieve higher frequency and higher power density with better efficiency.
High switching frequency introduces high power density. However, the switching loss and
magnetic components losses are increased. The emerging GaN devices [D.9]-[D.11] give the
opportunity to diminish the switching related loss. Hence, the magnetic design becomes very
critical.
96
Daocheng Huang Chapter 4
The isolated high output current DC/DC applications, like server, suffer very high
conduction loss, especially for the transformer and SR devices [D.12], [D.13]. Paralleling SR
devices are required to reduce device conduction loss. For winding loss, matrix transformer is
good candidate for its high current capability [D.14]. However, the price paid for matrix
transformer is multiple cores. Reference [D.15] uses flux cancellation method to reduce the core
number for less core volume and core loss. The drawbacks are expensive 12 layers PCB
transformer and the large conduction loss from alternative current through vias among PCB
layers.
To eliminate the AC conduction loss among layers, one effective way is mounting MOSFET
device on PCB board [D.17], [D.16]. This structure can help reduce conduction loss between
layers dramatically. Both transformer structures have litz wires for primary side windings and
PCB board for secondary side windings. Nevertheless, its primary winding is complicated and
hard to manufacture.
High termination losses are the third concern. Due to the proximity effect and skin effect, the
currents in adjacent terminals with opposite directions attract each other. Thus, very high losses
and hot spots are generated. This termination loss deteriorates efficiency significantly. For the
conventional design, all SRs are placed on the motherboard. Physically speaking, a large loop of
the secondary side rectifiers is inevitable. Consequently, a large distribution loss will be generated.
97
Daocheng Huang Chapter 4
For high frequency high step down LLC resonant converters, the transformer loss dominates
the whole converter loss [D.12]-[D.16], thus, the transformer design is very critical.
For conventional wired transformer, the primary side windings are solid or multi-strand
wires for low switching frequency and low cost design. At high frequency, litz wires are chosen
for lower conduction loss. For off-line dc-dc converters, the secondary side current is much
higher than the primary side. Therefore, copper foils are selected for the secondary side winding.
To alleviate ac winding loss, the primary side and the secondary side windings are interleaved as
a sandwich structure. Mostly, the secondary side windings are connected with the motherboard
via copper poles. However, this structure suffers high termination losses. Due to proximity effect,
the current surges in ac connection terminals. Meanwhile, very little current goes through the
center of the terminals because of the skin effect. Thus, very high losses and hot spot are
generated [D.17].
In reference [D.16], the secondary side windings are integrated with the SR devices on PCB
board, as shown in Fig.4.1. Virtually, termination is achieved at dc output. Thus, the termination
loss can be reduced considerably. However, there are some limitations. The primary side
windings are interleaved with the secondary side windings as one. For each cell, the primary side
winding is connected in series. To finish the whole transformer, multiple cells are connected in
parallel. As a result, this structure becomes very complicated. In addition, since all primary side
and secondary side windings are paralleled, current sharing between windings might be a
potential issue for some circumstances, especially for high current applications.
98
Daocheng Huang Chapter 4
This transformer structure is simplified by [D.17]. The primary side winding are placed in
series, and secondary windings in parallel, as shown in Fig.4.2. However, the manufacture
process is still complicated for half litz wires half PCB board transformer. The current sharing of
99
Daocheng Huang Chapter 4
It can achieve high power density and low profile. Mostly, multi-layer PCB board is used as
planar transformer windings. The primary side and secondary side windings interleaves as
The state-of-art industry product is Vicor BCM series, as shown in Fig.4.3. By the soft-
switching topology called Sine Amplitude Converter (SAC), which is very similar as LLC, the
module can achieve ZVS-ZCS operation. Thus, high efficiency and power density is achievable.
There are two half bridge stacked together at primary side, thus low voltage device can be utilized.
Two core transformer structure is used to help split secondary side current. The secondary side
100
Daocheng Huang Chapter 4
conduction loss is reduced. The typical power density of this series is about 1000W/in3, while the
peak efficiency is around 95.5%. However, this module utilizes 12 MOSEFTs, 14 layers PCB
Thus, how to improve the efficiency and power density of high step-down dc/dc converter is
The matrix transformer could help to fix the dilemma. The matrix transformer is defined as
an array of elements interwired so that the whole functions as a single transformer [D.14]. Each
element being a single transformer that contains a set turns ratio, i.e. 1:1, 2:1 ….n:1. The desired
101
Daocheng Huang Chapter 4
turns ratio is obtained by connecting the primary windings of the elements in series or parallel
and the secondary’s in series or parallel. For the high output current cases only a single turn
secondary will be considered. The benefits of the matrix transformer are that it can split current
between secondary windings connected in parallel, reduce leakage inductance by lowering the
N2 value of the secondary loop inductance, and improve thermal performance by distributing the
power loss throughout the elements. On the other hand, the matrix transformer structure also can
effectively reduce MMF (magnetomotive force) of windings, especially for PCB winding. That
Fig. 4.4 shows one typical example of 400V/12V 1kW LLC resonant converter. The GaN
HFETs Q1 and Q2 are primary devices. SR1, SR2, etc are synchronous rectifier (SR) devices.
102
Daocheng Huang Chapter 4
The resonant capacitor is Cr. Lr is the leakage inductance of transformer, while Lm is the
magnetizing inductance. The transformer turns ratio is 16:1:1. Based on optimized loss of
synchronous rectifier devices, four sets of center-tap output are chosen. The detail reasons are
discussed in [D.18].
Fig. 4.512 layer PCB structure with one core and its MMF
Fig. 4.5 shows the planar transformer structure employing Fig. 4.4 circuit by one core
structure and 12 layer PCB board as transformer windings. The primary side winding is in series,
and secondary side in parallel. All the windings are wrapped around the single core. 12 layer
PCB windings can be divided into 4 sections. Each section has three PCB layers with two layers
for secondary winding and the center one for primary side. As indicated in Fig. 4.5, when
secondary winding 1 conducts, the secondary winding 2 does not conduct due to center-tap
structure. The current direction for first and second layer PCB board is marked. The other
103
Daocheng Huang Chapter 4
sections are similar. The magnetomotive force (MMF) between primary and secondary windings
Fig. 4.6 shows the PCB winding structure employing matrix transformer concept. The
current direction for the first three PCB layers are shown, other layers are similar. The primary
and secondary windings wrap on two cores. The MMF between primary and secondary windings
are only twice of primary current, as indicated in Fig. 4.6. Low MMF means low leakage
Fig. 4.612 layer PCB structure with two cores and its MMF
However, 12 layers PCB board is seldom used in most front end applications, like server,
telecom, etc. Four layer PCB board is widely employed. Thus, matrix transformer based on 4
layer PCB board is adopted. The whole transformer is split into four small transformers, whose
primary side are in series and secondary side in parallel. Each small transformer has four turns
104
Daocheng Huang Chapter 4
primary windings and two turns center-tap secondary windings as indicated in Fig. 4.7. As
shown in Fig. 4.8, two PCB layers are taken for primary windings at top and bottom, and the
inner two layers for secondary windings. At this instant, the secondary winding 1 and primary
windings are conducted. The MMF between primary and secondary windings are only twice of
primary current, that is very similar as the MMF of 12 layer structure in Fig. 4.6. Consequently,
low MMF means low AC winding resistance and low leakage inductance of transformer. At the
same time, the current sharing among secondary side are automatically achieved by the structure
When low MMF is achieved, the core loss is increased because of multiple cores. The flux
excursion for each transformer core is the same in each matrix element as the traditional
transformer as mentioned in Fig. 4.5. The primary winding pattern with four magnetic cores in
105
Daocheng Huang Chapter 4
Fig. 4.8 is shown in Fig. 4.9. Just one of two primary winding layers is shown for simplicity. The
Fig. 4.8Four layer PCB structure with four cores and its MMF
Fig. 4.9 Primary side winding pattern with four U-I cores matrix transformer
106
Daocheng Huang Chapter 4
It has been known that using integrated magnetic structures can allow for flux cancellation
[D.15]. The matrix transformer configuration offers an ideal case for magnetic integration as a
result of the cores being excited with identical voltage-second generating the same flux in each
core. This allows for almost complete flux cancellation if designed properly. This can decrease
Fig. 4.10 Rearranged primary side winding pattern with four U-I cores
Fig. 4.11Primary side winding pattern for two E-I core matrix transformer
The primary side winding rearranged to reverse flux direction of core 2 and core 4 inFig.
4.10. Hence, the U-I core 1 and core 2 can both turn 90 degree and merge into E-I core 1’, while
core 3 and core 4 can do into core 2’ as shown inFig. 4.11. The flux density in each core is the
same due to same voltage-second, the magnetic flux in center leg of core 1’ can be cancelled, so
107
Daocheng Huang Chapter 4
can core 2’. Thus, the flux density in the center leg is nearly zero. The center leg of two E-I cores
actually can be reaped, so two U-I cores are gotten, as pictured inFig. 4.12. By flux cancellation,
four U-I cores of matrix transformer can be reduced to two U-I cores. The core loss and core size
can be reduced into half. Then, the whole circuit is shown inFig. 4.13.
Fig. 4.12Primary side winding pattern for two core matrix transformer with flux cancellation
108
Daocheng Huang Chapter 4
As mentioned above, the planar matrix transformer has only four layer PCB board as
windings, and easy manufacture. It also can effectively reduce leakage inductance and winding
AC resistance with low MMF compared to the traditional single transformer design. Meanwhile,
flux cancellation method will help reduce magnetic cores’ size and loss.
For better efficiency, the transformer winding structure needs more improvement. In [D.15]
and [D.17], we know the termination of secondary side windings introduces large AC conduction
loss. To eliminate the AC loss introduced by termination, SR devices need be integrated into
secondary side windings [D.16]. However, [D.16] did not givethe detail loss analysis and
optimal winding design. The following discussion gives insight analysis and optimal transformer
The matrix transformer structure shown in Fig. 4.8has two parts. Each part has 8 turns
primary windings in series, two sets center-taped secondary windings in parallel and one set of
U-I core. These two parts are also in series at primary side and in parallel at secondary side.
The first one shown in Fig. 4.13has good interleaving structure. The winding structure of
one U-I core indicated in dashed box is shown in Fig. 4.14andFig. 4.15. The top view is in Fig.
4.14, and the side view in Fig. 4.15. Primary windings locate top and bottom side of PCB board.
For one half circle of switching period, primary winding conducts current, when secondary
winding 1 (Sec1) conducts and secondary winding 2 (Sec2) does not. The magenetomotive force
109
Daocheng Huang Chapter 4
(MMF) of this structure is given in Fig. 4.15. However, the secondary windings need vias and
external terminal to connect the SR devices on top and bottom layers, as indicated in Fig. 4.14.
The Maxwell 3D Finite Element Analysis (FEA) simulation is applied to estimate the
leakage inductance and AC resistance of transformer windings. Fig. 4.16 shows the FEA
simulation results of AC current distribution for secondary side of transformer. The dash arrows
express the AC current direction. It is clear that there is severe current crowding along the
terminal connecting SR device and capacitors. The reason is that the termination does not
interleave with primary winding, thus, the AC currents in opposite direction will attract each
other along the edge. The doted box is where vias connecting the middle layer secondary
windings and the top layer. The current through vias is not even either.
110
Daocheng Huang Chapter 4
Fig. 4.15Cross view of the first winding arrangement and its MMF
Fig. 4.16 AC current distribution for secondary winding of the first winding arrangement
111
Daocheng Huang Chapter 4
The simulation result of one U-I core transformer is given in Fig. 4.17. The secondary side
112
Daocheng Huang Chapter 4
Fig. 4.18 FEA simulation for the first winding arrangement with output shorted
If the transformer secondary side is cut off as dash line indicated in Fig. 4.17(a), and shorted
by copper bar at the cut port. Fig. 4.18is the simulation result. The secondary side AC resistance
is Rsec=3.35mΩ, and the leakage inductance Lk = 58.0nH. This phenomenon means the AC
resistance of termination including via is 3.46 mΩ, and the leakage inductance 118.4nH.
However, there are opposite direction currents flow in and out the shorted port, which will also
113
Daocheng Huang Chapter 4
Fig. 4.19 FEA simulation for the first winding arrangement with secondary winding shorted
Fig. 4.19is the simulation result for the secondary winding totally shorted, that means no AC
current flow out and in secondary winding, and no termination loss. The AC current direction is
shown in solid line in Fig. 4.19. The AC resistance is Rsec=1.37mΩ, and the leakage inductance
Lk=36.6nH. Compared with Fig. 4.17, the AC resistance of secondary winding with termination
114
Daocheng Huang Chapter 4
Based on previous analysis, the lossy parts of the first winding arrangement are the terminal
and the vias which connect the secondary windings, SR devices and output capacitors. To
eliminate this termination related loss, the second winding arrangement is proposed whose SR
devices and output capacitors are integrated into secondary windings. For this one, no extra
terminal needed for devices and capacitors connection. The devices and capacitors are naturally
part of secondary side windings. The AC current loop of secondary winding is exactly matching
those of primary side winding. There is no AC current flowing out and in secondary side
115
Daocheng Huang Chapter 4
The second winding arrangement is proposed in Fig. 4.20 and Fig. 4.21. The secondary
windings locate top and bottom side of PCB board. The SR MOSFETs and output capacitors are
part of secondary windings. In Fig. 4.21, the MMF between windings is higher than that of the
first winding arrangement in Fig. 4.15, which means this winding structure has worse
interleaving.
116
Daocheng Huang Chapter 4
The FEA simulation results are given in Fig. 4.22. The secondary side AC resistance is
Rsec=2.08mΩ, and the leakage inductance Lk = 63.4nH.Although the first winding arrangement
has better interleaving, its AC resistance and leakage inductance are much higher than the second
one. That means the termination loss is much larger than the loss saved by better interleaving
structure.
In the first winding arrangement, SR devices connect secondary side winding byvias and
external connection, which cause huge AC conduction loss. The second reason is that its primary
winding and secondary winding are not exactly match each other. When the windings are not
overlapped very well, the leakage flux induced by those parts will force the current crowded to
the edge of windings. In the second winding arrangement, the SR devices are integrated into
secondary windings, thus, there is no termination loss. The primary and secondary windings are
exactly overlapped, thus, there is nearly no current crowding anywhere in this case as shown in
At the beginning of detail transformer design, the transformer width is constrained by the
dimension of synchronous rectifier devices. For this case, we choose Infineon device SuperSO8
package, the minimal width of whole transformer is 70mm. Then, 1 MHz is picked as the
switching frequency. The core material 3F45 is chosen based on performance factor [B.25]. Then,
the loss density is shown in Fig. 4.23. As the cross area increases, the core loss drops
dramatically. The curve is reach diminishing returns around shadow area. One point (Ae=44mm2)
is chosen in shadow area based on the tradeoff of core size and loss.
117
Daocheng Huang Chapter 4
As shown in Fig. 4.24, the core shape does not only influence the core loss but also winding
loss. Because the transformer width is determined, we can only change the a and b value of core
to get the minimal winding loss. Fig. 4.25 and Fig. 4.26 show the trend of AC and DC resistance
118
Daocheng Huang Chapter 4
of secondary winding and primary winding, which changes as a and b ratio changes. At last, we
119
Daocheng Huang Chapter 4
The last step is chosen suitable winding thickness. The simulation results are given in Table
2.1. The skin depth at 1 MHz is around 66um. However, the results show the optimal thickness is
An 1MHz 390V/12V 1kW LLC resonant converter prototype with proposed matrix
transformer structure is built. The second winding arrangement is applied. The circuit is given in
120
Daocheng Huang Chapter 4
The primary devices are Transphorm GaN HEMTs. For better efficiency, two GaN devices
is paralleled. Thus, there are four devices at primary side. SR devices are BSC010N04LSI from
Infineon. The core material is 3F45.The magnetizing and leakage inductances are used as
resonant elements, which are integrated into matrix transformer. The leakage inductance of
matrix transformer is 220nH, while the magnetizing inductance is 17.6uH. The resonant
121
Daocheng Huang Chapter 4
122
Daocheng Huang Chapter 4
Fig. 4.29, Fig. 4.30 and Fig. 4.31show the waveforms under 15%, 50% and 100% load.
Vds_Q2 is the drain-source voltage waveform of primary device Q2. ICr is the current through
resonant capacitor Cr. Even as high as 1 MHz switching frequency, the primary side devices can
easy achieve Zero-Voltage-Switching (ZVS). The oscillation during dead time is caused by the
leakage inductance and secondary rectifier’s junction capacitance. The turnoff current is as low
as 2A.
One of the best industry products on market is Vicor module, whose power density is around
1050W/in3. To achieve the efficiency and power density, it has 14 layer PCB board, 12
MOSFETs for 300W output power. Compared with this product, our prototype just has 4 layer
PCB and 12 devices for 1kW to reach similar power density and efficiency. The prototype
efficiency can reach as high as 95.4%. The efficiency comparison is shown in Fig. 4.32.
123
Daocheng Huang Chapter 4
Fig. 4.32The efficiency comparison for CPES prototype and industry product
One more thing needs to clarify is that the advantage of GaN devices is smaller Coss
compared with Si MOSFET having the same Rdson. That will result in lower turn off current
which help achieve zero-voltage switching. Lower turn off current means less circulating energy
in the circuit. Thus, the major loss reduction parts caused by GaN device are the conduction loss
and driving loss of primary devices, the conduction loss of primary winding of transformer.
While the major loss saved by new transformer structure is secondary side winding conduction
loss and termination loss. The detail analysis for GaN device benefits is described in [D.20].
124
Daocheng Huang Chapter 4
Based on previous Maxwell 3D simulation, the new winding structure can save more than
60% secondary side winding loss under full load. More than 20% of total loss is reduced. The
detail loss breakdown for 100% load and 15% load are given in Table 4.2 and Table 4.3. It is
clear to see the major loss is distributed around transformer and secondary rectifier devices at
full load.
4.6 Conclusion
125
Daocheng Huang Chapter 4
To deal with the high output current applications, matrix transformer structure help reduce
the leakage inductance and winding AC resistance of transformer. The price is the rising of cores
loss and volume due to multiple magnetic cores. Flux cancellation reduces core size and core
loss. Then, SR devices and output capacitors are integrated into secondary side windings to
eliminate the termination loss. A high efficiency high power density matrix transformer structure
126
Daocheng Huang Chapter 5
voltage and current stresses of all resonant elements are examined. Based on stress, the principles
of choosing suitable passive components for integration are proposed. Then, the magnetic
integration method is shown based on multi-winding transformer structure. The basic principles
of passive integration are discussed. A novel passive integration method is proposed for multi-
elements resonant converters. A 1000 W, 800 kHz, 400 V/48 V test board for resonant tanks is
5.1 Introduction
To make practical use of LLC and CLL resonant converters, the over current protection has
to be fulfilled, especially for startup and over load conditions. The purpose of over current
protection is to limit the current stress in the system during over load or short circuit condition,
also to limit the inrush current during start up so that the power converter can be protected from
destructive damage. Multi-element resonant converters were proposed to solve this issue [E.1]-
[E.2]with more passive components added to the resonant tank. However, the additional passive
components impose the demand for integration efforts in order to alleviate their impact on
converter size.
At a high switching frequency, the passive components’ volume can be reduced. However,
in the state-of-the-art resonant converters, the discrete passive components and the heat sink still
occupy more than 80% of the total system volume [E.3]. To reduce the volume of the magnetic
127
Daocheng Huang Chapter 5
components, magnetic integration has been proposed. However, the passive components still
have large profile. To further reduce the overall volume, passive integration technology is
applied to integrate the resonant inductor (Lr) and capacitor (Cr), the magnetizing inductor (Lm),
and the transformer (Tx) (L-L-C-T) into one module [E.4]-[E.10]. There is still a challenge to
The LLC resonant tank can be considered as a band pass filter which includes series
resonant frequency (SRF) and parallel resonant frequency (PRF), as shown in Fig. 5.1 and Fig. 5.2.
The series resonant frequency is created by Lr and Cr, black dot in Fig. 5.2. It is the optimal point
at nominal operation. The fundamental component of input energy can be delivered from the
source to the load very efficiently. Therefore, high efficiency can be achieved. The hold-up time
capability is given by the parallel resonant frequency, dash line oval in Fig. 5.2. This resonant
128
Daocheng Huang Chapter 5
However, with poor frequency selectivity, namely, very wide bandwidth, the frequency has
to be increased very high to achieve enough damping effect. To improve the characteristics of
LLC resonant converters, additional resonant elements are needed. With additional resonant
element component, a multi-element resonant tank, which combines band pass filter and notch
filter, is proposed to solve the current protection issues. One of these resonant converters is
depicted in Fig. 5.3. The notch filter section is created with Lp and Cp. The band pass filter section
129
Daocheng Huang Chapter 5
The voltage gain of this four-element resonant tank is illustrated in Fig. 5.4. The resonant
tank with notch filter characteristic can create zero voltage gain. Conceptually, infinite
impedance can be created when frequency operates at the resonant frequency f02 of the notch
filter. As a result, if overload or even shorted output condition occurs, the current can be limited
inherently by the resonant tank characteristic. The notch filter center frequency f02 can be
In general, with variable frequency control, the resonant tank input voltage is excited as a
square waveform. According to the Fourier analysis, the voltage excitation only consists of odd
harmonics. Therefore, to avoid circulating energy at nominal condition, notch filter resonant
130
Daocheng Huang Chapter 5
As shown in Fig. 5.5, the voltage and current stresses of LLC and proposed 4-element
When converter operates at f01, the notch filter represents inductive. The impedance of Cp is
much larger than Lp. The major part of primary side current flows through Lp, not Cp. The current
With leakage inductance Lr, a second band pass filter is created. A 5-elements resonant tank
is given as an example, shown in Fig. 5.6. The second band pass filter is designed at the three
times of the nominal frequency. The third order harmonics energy of primary side can be
delivered through this band pass filter. Obviously, the power delivery is more efficient.
However, there are 6 passive components in resonant tank. The high number of passive
components might increase the size considerably. It is very desirable to integrate the passive
131
Daocheng Huang Chapter 5
To improve the power density, the magnetic integration method is widely applied in
resonant converters. For LLC resonant converters, Lr is the leakage inductance, and Lm is the
132
Daocheng Huang Chapter 5
For 5-elements resonant converters, there are four magnetic components: Lr, Lp, Lm, and
transformer. It is hard to integrate all components into one module by traditional transformer
As mentioned in [E.9], cantilever model is suited for multiple-winding magnetic model. Fig.
5.8(a) gives the cantilever model for LLC center-tap transformer. Winding 1 is the primary side
winding, and winding 2, 3 are two secondary side windings. The effective leakage inductance l12,
l13, l23 represent the couple relationship between winding 1, 2, and 3. n2, n3 represent the
Normally, the two secondary side windings are very close, and have same turns (n2=n3),
thus, l23 is negligible. Thus, l12, l13 can be combined as l123, as shown in Fig. 5.8 (b). Then, this
model can be transferred into equivalent model in Fig. 5.8(c).Here, L112/ (L11+l123)represents the
magnetizing inductance (Lm), sodoes (L11×l123)/ (L11+l123) the leakage inductance (Lr).
133
Daocheng Huang Chapter 5
L 11 l123 l
L 11 + l 123 1 : n 2 1 + 123
L 11
L 112
1 L 11 + l 123 2
l
1 : n 3 1 + 123
L 11
(c) Equivalent model for LLC transformer
With traditional transformer structure, only series resonant inductor and magnetizing
inductor can be integrated. To integrate the third resonant inductor, one more winding (winding 4)
134
Daocheng Huang Chapter 5
The effective leakage inductance l14, l24, l34 represent the couple relationship between
winding 1, 2, 3 and 4. n4 represent the turns ratio of winding 4 with winding 1. The cantilever
As mentioned above, l23 is small enough to be negligible, and l12, l13 can be combined as l123.
If winding 4 is not coupled tightly with winding 2 and 3, l42 and l42 would be large enough to be
135
Daocheng Huang Chapter 5
The resonant tank connection is shown in Fig. 5.11 (a). The dash lines are the connecting
wires among integration module and discrete capacitors Cr and Cp. The winding 1 and 4 share
the same ground. When n4=1, the node A and B have the same electrical potential, so they can
be treated as virtually shorted as in Fig. 5.11 (b). Thus, the final resonant tank is Fig. 5.11 (c). The
136
Daocheng Huang Chapter 5
Fig. 5.11 Equivalent circuit for discrete Cr, Cp and integrated magnetics
The gain curves for this multi-element resonant converter are shown in Fig. 5.12, which is
very similar as Fig. 5.9. Namely, superior merits, full load range ZVS, good frequency
controllability for current limit and voltage gain, can be successfully obtained.
137
Daocheng Huang Chapter 5
Each parameter of the cantilever model can be directly measured. All magnetic components
For simplification, an easy way to understanding the integration method is based on the
magnetic relationship between windings. Fig. 5.13 (a) shows the integrated magnetic module
which includes transformer (Tx), magnetizing inductance (Lm), leakage inductance (Lr) and Lp.
The equivalent circuit is given in Fig. 5.13 (b). Lr is the leakage inductance indicating the
the magnetic decoupling of winding 1 and winding 4. Magnetizing inductance (Lm) is determined
138
Daocheng Huang Chapter 5
The turns of winding 1 and winding 4 is the same, and these two windings are connected at
one terminal. Thus, we can transform Fig. 5.13 (b) to Fig. 5.14 (a). While Lr is determined by the
distance between primary winding (1,4) and secondary winding (2, 3), so Fig. 5.14 (a) can be
transferred into Fig. 5.14 (b), which is similar as the resonant tank in Fig. 5.6.
Fig. 5.15 Volume comparison of proposed and traditional magnetic integration method
139
Daocheng Huang Chapter 5
One magnetic module is built to verify the volume improvement. The previous magnetic
integration method utilizing magnetizing inductance and leakage inductance of transformer, but
cannot integrate Lp. The proposed method can integrate all the magnetic components. The
previous magnetic components volume is 39.73cm3. The new magnetic module is 16.23cm3.
The experimental waveforms are provided in Fig. 5.16 (a). It is clear that the fundamental go
through winding 1 and the 3rd harmonic through winding 4. For fundamental, the impedance of
Cp and Lr is very high, while Lp and Lr is relative low. Thus, major part of fundamental flew
through winding 1. For 3rd harmonic, the impedance of Cp and Lr is very low, while Lp and Lr is
relative high. Thus, major part of 3rd harmonic flew through winding 4.
In order to further improve the power density, passive integrationincluding the resonant
capacitors is required.
140
Daocheng Huang Chapter 5
Firstly, there are two resonant capacitors (Cr and Cp) in the resonant tank. Which capacitor
to capacitor’s lifetime. High voltage stress or high current stress will cause short life time of
capacitors, in other words, short life of whole converter. Thus, low stress resonant capacitor
ca
should be picked.
Based on the analysis of Fig. 5.16, we can see all current including fundamental and 3rd
harmonic flow through Cr, only small 3rd harmonic through Cp. For half bridge structure, there is
less stress than Cr. Thus, Cp should be taken into integrated module.
A D
C (L+M)/2
141
Daocheng Huang Chapter 5
LC cell is the basic element in passive integration. Its structure is shown in Fig. 5.17(a). The
dielectric layer is covered by copper layers at the both side. The lossless symmetric model of this
structure is given in Fig. 5.17(b). C is the capacitance of LC cell, while L is the self-inductance of
one side copper strip and M is the mutual inductance. Its equivalent circuit measured between
terminal A and D is a series of inductor and capacitor, as shown in Fig. 5.17(c).The value of
inductance and capacitance can be controlled by cascading LC cells, as shown in Fig. 5.18. The
equivalent capacitors are in parallel and the equivalent inductors are in series.
ε 0 ⋅ ε r ⋅ Acu
C= (5.1)
Tdi
C is the capacitance. Acu is the area of each plate. εr is the relative static permittivity
(dielectric constant) of the material between the plates. ε0 is the permittivity of free space. Tdi is
The passive integration with a stacked structure for resonant converters has been proposed to
integrate the LLCT module to achieve high power density. Fig. 5.19gives the winding structure of
LLCT module. The exploded view of an LLCT module with the stacked structure is shown in Fig.
5.20. Two sets of C core and I core constitute the two winding windows. The secondary winding
142
Daocheng Huang Chapter 5
is made of thin copper strips. The primary winding is implemented with cascading LC cells in
order to integrate the resonant capacitor in to the transformer. The cells are connected at the
terminals through the interconnections on the vertical surface at the two ends of the module as
shown in Fig. 5.20. The cell dimensions and the properties of the dielectric substrate determine
the resonant capacitance (Cr). The magnetizing inductance (Lm) can be adjusted by changing the
length of the air gap. By inserting leakage layer between the primary and secondary windings,
For the 5-element resonant tank, it is difficult to integrate both capacitors. The choice of
current stress will cause short life time of capacitor. In this particular topology, Cr has very high
143
Daocheng Huang Chapter 5
DC voltage bias while Cp only has small AC voltage. Moreover, Cr carries all the primary
current while Cp only carries the third order harmonics as discussed before. Thus, Cr has much
higher voltage and current stress than Cp, in other words, less reliable. Thus, Cp is chosen to be
The integrated transformer structure for Lp,Lr,Lm,Cp, and transformer is similar to the
integration technique for magnetic integration except that one winding (winding 1) is replaced by
LC cell, the connection is shown in Fig. 5.21(a). It is a 4-winding structure and the cantilever
model is introduced to derive its equivalent circuit. Winding 1 and 4 are primary windings
constructed by LC cell and copper wire, respectively. The LC cell interconnection is like Fig. 14.
That means the equivalent capacitor of LC cell is in series of parasitic inductance of winding 1,
like Fig. 5.21(b). Winding 2 and 3 are secondary side windings. L11 is the self-inductance of
144
Daocheng Huang Chapter 5
winding 1. The effective leakage inductance l12, l13, l14, l23, l24, l34 represent the couple
relationship between winding 1, 2, 3 and 4. n2, n3, n4 represent the turns ratio of winding 2, 3, 4
(a) (b)
(c)
Normally, the two secondary side windings are very close, and have same turns (n2=n3),
thus, l23 is negligible. Thus, l12, l13 can be combined as l123, so can l24, l34 as l423, as shown in Fig.
5.22. The dash lines represent connection wire between integration module and Cr. If winding 4
is not coupled tightly with winding 2 and 3, l423 would be large enough to be ignored. Then, it is
145
Daocheng Huang Chapter 5
the same topology as in Fig. 5.12 (a). Thus, it also can be modified as the resonant tank in Fig.
Thus, all passive components are integrated except Cr (the high stress component). All the
leakage inductance can be tuned by adjusting the distance between windings or with magnetic
The transformer structure in Fig. 5.23is given for example. Cp is determined by LC cell in
winding 1. L11 is controlled by air gap. l14 (Lp) is controlled by magnetic shunt between winding
1 and 4. l123 (Lr) is controlled by magnetic shunt between winding 1 and 2. Winding 4 can be
146
Daocheng Huang Chapter 5
Different with the transformer module before, passive integrated transformer including LC
cell is not suited to use the same measure method. The capacitance of LC cells makes the
measurement method invalid. A new measure method is proposed based on cantilever model.
The transformer model of proposed passive integration structure is shown in Fig. 5.24.
147
Daocheng Huang Chapter 5
First, the self-inductance L11and capacitance C are measured based on impedance analyzer
To measure the effective turns ratios n2, n3,...,nk, and AC voltage V1is applied to winding 1,
with the other windings open circuited. The effective turns ratio nk, is given by
1
+ j ω L11
V k jω C V ω 2 L11 C − 1
nk = = k
V1 jω L11 V 1 ω 2 L11 C (5.2)
Vk is the measured voltage of winding k. ω is the angular frequency of AC voltage applied to
winding 1. A negative value of nk indicates that the winding polarity marks should be reversed.
Direct measurement is hard for this transformer structure due to LC cell. All the inductance
can be calculated based on impedance measurement. Six measurement cases are needed for
148
Daocheng Huang Chapter 5
Case 1 is measuring the impedance of winding 1 port by shorting winding 2, 3 and 4. The
Case 2 is measuring the impedance of winding 1 port by shorting winding 2, 3 and opening
149
Daocheng Huang Chapter 5
Case 3 is measuring the impedance of winding 1 port by shorting winding 3, 4 and opening
Case 4 is measuring the impedance of winding 1 port by shorting winding 2, 4 and opening
Case 5 is measuring the impedance of winding 4 port by shorting winding 2, 3 and opening
Based on above 6 cases, all effective leakage inductances can be calculated. The calculated
The final parameters of integrated module after simplified are shown in Fig. 5.27.
150
Daocheng Huang Chapter 5
The volume comparison is given inFig. 5.28. The volume of previous magnetic components
Fig. 5.28 The volume comparison of passive module and discrete components
151
Daocheng Huang Chapter 5
Associated with the increasing power density, loss density increases. Although the loss
density in the passive component is much lower than that in power semiconductor devices, the
lower thermal conductivities of most materials applied in passive components leads to high
temperature gradient inside the component. The thermal issues limit the increase of power
density. The maximum allowed temperature inside an integrated module is one of the most
Although the surface temperature of a passive module can be controlled by the external
cooling conditions, the temperature rise inside the module is determined by the loss distribution,
the material properties and the structure. For a practical design, the structure is basically
determined by the considerations of electromagnetic function, and the materials are generally
selected for their electromagnetic characteristics to meet the required parameter values. When
the structure and materials are fixed, the loss distribution is determined by the circuit operation,
which is normally also fixed. Thus, itis difficult to improve the thermal performance of an
existing design without changing the structure or materials. The most common approach to
reduce the inside temperature gradient is to increase the dimensions, which reduces the loss
density and increase the heat dissipation area, however, sacrifices the power density. It is clear
that in cases where the thermal constraint is the dominant design criterion, the heat dissipating
ability of a module is directly related to the power density. In other words, by improving the heat
dissipating ability, the power density can be improved. Being aware of this, the heat extraction
technology is developed[E.12].
152
Daocheng Huang Chapter 5
To apply heat extractors in power electronics module, the heat extractor plate should be
parallel to the magnetic flux to avoid influencing the electromagnetic performance. The structure
shown in Fig. 5.29can embed heat extractors without change the electromagnetic performance,
but the inside filed distribution changes due to the redistribution of the magnetic flux. The
induced fringing effect may even influence the conduction loss. If the heat extractors occupy a
The embedding of heat extractors also changes the distribution of the thermal field.
Originally regarded as a uniform heat source, the core is now several individual heat sources
In the integrated module, there are two heat sources: the winding block and the magnetic
core. By applying the superposition principle, the amounts of heat flux generated by these two
heat sources can be studied separately, and the results can be combined linearly. For the heat
generated inside the winding block, both the core and heat extractors are conduction channels,
through which heat can be conducted to the heat sink. The internal and external thermal contact
153
Daocheng Huang Chapter 5
resistance and the equivalent thermal resistance of the combination of the core and heat
For heat generated in the core, the winding block functions as a conductor connecting the
core and heat extractors. The internal thermal contact resistance functions twice on one of the
heat paths. Because of the different heat distribution, the equivalent thermal resistance of the
combination of core and heat extractors is different from that for heat coming from inside the
winding block.
The equivalent structures of both cases are shown in Fig. 5.30, where the core and the
winding block are replaced by equivalent spot heat sources, and the corresponding equivalent
thermal resistance is applied. Here, the thermal conductivity of core material (MnZn ferrites) is
about (3.5~5.0) x 10-3K·m·W−1, while the thermal conductivity of heat extractor (aluminum
nitride), is about 170~190 K·m·W−1. The thermal conductivity of heat extractor is much larger
than core material. Thus, large portion of heat generated by windings and cores would pass
154
Daocheng Huang Chapter 5
The core dimension is given by Fig. 5.31, while the heat extractors are made of 0.5mm
aluminum nitride substrates and have the same cross-sectional dimensions with the core. The
core material is 3F4. The whole core is combined by 9 pieces of 3F4 ferrite and 8 pieces of heat
155
Daocheng Huang Chapter 5
The volume comparison after adding heat extractor is given in Fig. 5.33.
Fig. 5.33 The volume comparison of passive module and discrete components
An 800 kHz 1.2kW 400V/48V five-element integration prototype is shown in Fig. 5.34 (a).
The parameters in resonant tank are Cr=12nF, Cp=5nF, Lp=1.2uH, Lr=0.9uH, Lm=10uH. The
turns ratio is 4:1:1. The no load and 50% load waveforms are shown in Fig. 5.34 (b), (c). The
waveforms for secondary side short-circuit is given in Fig. 5.34 (d). The output current is
suppressed to 20A at 1.6 times of resonant frequency, which is less than full load current. The
156
Daocheng Huang Chapter 5
400V No load
Vds
Vgs
0V
4A
0A
-4A icr
Fig. 5.34Experimental results for five-element resonant converter with passive integration module
5.8 Conclusion
Based on this method, the passive integration for 3-element, or higher order elements resonant
converters are achievable. Most of passive components (capacitors, inductors and transformer)
are integrated into one module to achieve high power density. The proposed multi-winding
transformer structure with integrated inductor and capacitor are analyzed with a detailed
157
Daocheng Huang Chapter 5
cantilever model. Design guidelines are summarized for the control of the component values.
One prototype of 1.2kW, 800 kHz 400V/48V 5-element resonant converter is built and tested to
verify the proposed structure. The power density can be achieved as high as 171W/inch3.
158
Daocheng Huang Chapter 6
6.1 Conclusion
The LLC resonant converter exhibits higher efficiency and higher power density than
conventional PWM converters. Thus, it has been widely adopted as a desirable power supply for
telecoms, servers, desktops, laptops, flat-panel TVs, LED lighting, etc. To further improve the
LLC performance, several novel concepts and techniques have been developed in this
dissertation.
The high switching frequency is needed recently for high power density requirement.
However, LLC resonant converter suffers high transformer loss. Matrix transformer is
introduced to reduce winding loss and total volume. Flux cancellation method is utilized to
reduce core size and loss. Synchronous Rectifier (SR) devices and output capacitors are
integrated into secondary windings to eliminate termination related winding losses, via loss and
To solve the inherent issues, like start-up and short-circuit protection, SR driving and EMI,
etc., a systematic method is proposed to find the similar resonant topologies like LLC. Based on
this method, lots of high order resonant converters are found to solve the issues LLC type
proposed. State-plane analysis with new normalization factors is utilized. Based on it, the voltage
159
Daocheng Huang Chapter 6
stress, current stresses and apparent power of resonant converters are easy to compare. This
method can help select suitable circuit topology for certain application. Meanwhile, it also can
help resonant converters’ design. The important performance factors, like start-up, short-circuit
protection, SR driving and EMI, are also taken into account for the whole evaluation system.
The passive integration is necessary for high power density resonant converter, especially
for high order system. Based on stress, suitable passive components are chosen for integration.
Then, the magnetic integration method is shown based on multi-winding transformer structure.
The passive integration principles are discussed. A novel passive integration method is proposed
In conclusion, this work is focus on the topology analysis and integration of resonant
converters. Searching the suitable topologies for certain application, and evaluate the
performance of them. Then, improve the system power density by integration techniques.
All of these novel implementations proposed in this work will help find valuable resonant
converters and evaluate their performance. Following this research, there are still some
1. The proposed matrix transformer is high power density and high efficiency, but its EMI
performance is unknown. The continuous work may study the EMI noise reduction for matrix
transformer.
160
Daocheng Huang Chapter 6
a lot. If passive integration techniques cooperates with matrix transformer, how this impact the
efficiency and power density of whole system is interesting for future study.
3. The state-plane with new normalization can be extent to not only resonant converters, but
161
Daocheng Huang References
References
A. Introduction
[A.1] W. A. Tabisz, M. M. Jovanovic, and F. C. Lee, "Present and future of distribution power
systems", in Proc. APEC 1992, pp. 11-18.
[A.2] G. C. Hua, W. A., Tabisz, C. S. Leu, N. Dai, R. Watson, F. C. Lee, “Development Of a
dc distributed power system,” in Proc. IEEE APEC 1994, vol.2, pp. 763 -769.
[A.3] F.C. Lee, P. Barbosa, P. Xu, J. Zhang, B. Yang, F. Canales, “Topologies and design
considerations for distributed power system applications,” in Proc. of the IEEE, Volume 89
Issue: 6, June 2001, pp: 93 –950.
[A.4] S. K. Mazumder, K. Shenai, “On the reliability of distributed power systems: a macro- to
micro- level overview using a parallel DC-DC converter,” in Proc. IEEE PESC, 2002, pp.
809-814.
[A.5] M. M. Jovanovic, "Technology drivers and trends in power supplies for
computer/telecom," APEC 2006, Plenary session presentation.
[A.6] A. Pratt, P. Kumar, T. V. Aldridge, “Evaluation of 400V DC distribution in telco and data
centers to improve energy efficiency,” in Proc. IEEE INTELEC, 2007, pp. 32-39.
[A.7] M. Ton, B. Fortenbery, and W. Tschudi, “DC power for improved data center
efficiency," [Online]. Available: http://hightech.lbl.gov/dc-powering/about.html, Jan. 2007.
[A.8] D. J. Becker, "400Vdc power distribution: Overcoming the challenges," in Proc. IEEE
INTELEC, 2010, pp. 1-10.
[A.9] 80Plus Program [Online]. Available: http://www.80plus.org.
[A.10] Energy Start Program [Online]. Available: http://www.energystar.gov, 2012.
[A.11] Climate Savers Computing Initiative [Online]. Available: http://www.climatesavers
computing.org, 2012.
[A.12] Texas Instruments User’s Guide (Nov. 2009). UCC28810EVM-003 110W multiple string
162
Daocheng Huang References
LED driver with universal line input and PFC [Online]. Available: http://www.ti.com
/lit/ug/sluu380b/ sluu380b.pdf.
[A.13] H. Chiu, Y. Lo, J. Chen, S. Cheng, “A high-efficiency dimmable LED driver for low-
power lighting applications,” IEEE Trans. on Industrial Electronics, vol. 57, Issue 2, pp. 735-
1743, Feb. 2010.
[A.14] Q. Hu, R. Zane, “LED driver circuit with series-input-connected converter cells operating
in continuous conduction mode,” IEEE Trans. on Power Electronics, vol. 25, Issue 3, pp.
574-582, Mar. 2010.
[A.15] H. Wu, S. Ji, F. C. Lee, X. Wu, “Multi-channel constant current (MC3) LLC resonant
LED driver,” in Proc. IEEE ECCE’11, pp. 2568- 2575, 2011.
[A.16] D. Reusch, F. C. Lee, D. Gilham, Y. Su, "Optimization of a high density gallium nitride
based non-isolated point of load module", in Proc. IEEE ECCE 2012, pp. 2914-2920.
[A.17] X. Huang, Z. Liu, Q. Li, F.C. Lee, "Evaluation and application of 600V GaN HEMT in
cascode structure," in Proc. IEEE APEC 2013.
[A.18] S. Ji, D. Reusch, F. C. Lee, "High-frequency high power density 3-D integrated gallium-
nitride based point of load module design," IEEE Trans. on Power Electronics, vol. 28, Issue
9, pp. 4216-4226, Sep. 2013.
[A.19] Y. Su, Q. Li, F. C. Lee, "Design and evaluation of a high-frequency LTCC inductor
substrate for a three-dimensional integrated DC/DC converter," IEEE Trans. on Power
Electronics, vol. 28, Issue 9, pp. 4354-4355, Sep. 2013.
[A.20] W. Chen, F.C. Lee, M.M. Jovanovic, J.A. Sabate, “A Comparative Study of A Class of
Full Bridge Zero Voltage Switched PWM Converters,” Proc. IEEE APEC, 1995, pp. 893-899.
[A.21] A.W. Lotfi, Q. Chen, F.C. Lee, “A Nonlinear Optimization Tool For The Full Bridge
Zero Voltage Switched DC-DC Converter,” Proc. IEEE PESC ‘92, 1992, pp. 1301-1309.
[A.22] Xinbo Ruan; Yangguang Yan, “Soft-Switching Techniques for PWM Full Bridge
Converters,” Proc. IEEE PESC ’00, 2000, pp. 634 -639 vol.2.
[A.23] J.G. Cho, J.A. Sabate, G. Hua, and F.C. Lee, “Zero Voltage and Zero Current Switching
Full Bridge PWM Converter for High Power Applications,” Proc. IEEE PESC ’94, 1994.
163
Daocheng Huang References
[A.24] J.H. Liang, Po-chueh Wang, Kuo-chien Huang, Cern-Lin Chen, Yi-Hsin Leu, Tsuo-Min
chen, “ Design Optimization For Asymmetrical Half Bridge Converters,” Proc. IEEE
APEC ’01, 2001, pp. 697-702, vol.2.
[A.25] Y. Leu, C. Chen, “Analysis and Design of Two-Transformer Asymmetrical Half-Bridge
Converter,” Proc. IEEE PESC ’02, 2002, 943-948.
[A.26] S. Korotkov, V. Meleshin, R. Miftahutdinov, S. Fraidlin, “Soft Switched Asymmetrical
Half Bridge DC/DC Converter: Steady State Analysis. Analysis of Switching Process,” Proc.
Telescon ’97,. 1997, pp. 177-184.
[A.27] L. Krupskiy, V. Meleshine, A. Nemchinov, “Unified Model of Asymmetrical Half Bridge
for Three Important Topological Variations,” Proc. IEEE INTELEC ’99, 1999, pp.8.
[A.28] W. Chen, P. Xu, F.C. Lee, “The Optimization Of Asymmetrical Half Bridge Converter,”
Proc. IEEE APEC ’01, 2001, pp. 603-707, vol.2.
[A.29] Bo Yang, “Topology Investigation for Front End DC-DC Power Conversion for
Distributed Power System," PhD Dissertation, Dept. ECE., Virginia Tech, 2003.
[A.30] Intel Corporation, NEC Corporation, Dell Computer Corporation, Data General a
division of EMC Corporation, Compaq Computer Corporation, Silicon Graphics Inc., and
International Business Machines Corporation, “A server system infrastructure (SSI)
specification for entry chassis power supplies," 1998.
[A.31] R. Oruganti and F.C. Lee, “Effect of Parasitic Losses on the Performance of Series
Resonant Converters,” Proc. IEEE IAS, ’85, 1985.
[A.32] R. Oruganti, J. Yang, and F.C. Lee, “Implementation of Optimal Trajectory Control of
Series Resonant Converters,” Proc. IEEE PESC ’87, 1987.
[A.33] A.K.S. Bhat, “Analysis and Design of a Modified Series Resonant Converter,” IEEE
Trans. on Power Electronics, 1993, pp. 423-430.
[A.34] J.T. Yang and F.C. Lee, “Computer Aided Design and Analysis of Series Resonant
Converters,” Proc. IEEE IAS ’87, 1987.
[A.35] V. Vorperian and S. Cuk, “A Complete DC Analysis of the Series Resonant Converter,”
Proc. IEEE PESC’82, 1982.
164
Daocheng Huang References
[A.36] F.S. Tsai, and F.C. Lee, “A Complete DC Characterization of a Constant- Frequency,
Clamped-Mode, Series Resonant Converter,” Proc IEEE PESC’88, 1988.
[A.37] R. Oruganti, J. Yang, and F.C. Lee, “State Plane Analysis of Parallel Resonant
Converters,” Proc. IEEE PESC ’85, 1985.
[A.38] R. Liu, I. Batarseh, C.Q. Lee, “Comparison of Capacitively and Inductively Coupled
Parallel Resonant Converters,” IEEE Trans. On Power Electronics, 1993, pp. 445-454, vol.8,
issue 4.
[A.39] M. Emsermann, “An Approximate Steady State and Small Signal Analysis of the Parallel
Resonant Converter Running Above Resonance,” Proc. Power Electronics and Variable
Speed Drives ’91, 1991, pp. 9-14.
[A.40] Y.G. Kang, A.K. Upadhyay, D. Stephens, “Analysis and Design of a Half Bridge Parallel
Resonant Converter Operating Above Resonance,” Proc. IEEE IAS ’98, 1998, pp. 827-836.
[A.41] A.K.S. Bhat, “Analysis and design of LCL-type series resonant converter,” in Proc. IEEE
INTELEC, 1990, pp: 172 - 178.
[A.42] B. Yang, F.C. Lee, A.J. Zhang and G. Huang, “LLC Resonant Converter For Front End
DC-DC Conversion,” in Proc. IEEE APEC, 2002, vol. 2, pp. 1108-1112.
[A.43] B. Lu, W. Liu, Y. Liang, F. C. Lee, and J. D. van Wyk, “Optimal Design Methodology
for LLC Resonant Converter,” in Proc. IEEE APEC, 2006, pp. 533–538.
[A.44] D. Fu; Y. Liu; F.C. Lee, M. Xu, “A Novel Driving Scheme for Synchronous Rectifiers in
LLC Resonant Converters,” IEEE Trans. on power electron. vol. 24, iss. 5, pp: 1321 – 1329,
May 2009.
[A.45] H. Groot, E. Janssen, R. Pagano, and K. Schetters , “Design of a 1-MHz LLC Resonant
Converter Based on a DSP-Driven SOI Half-Bridge Power MOS Module”, IEEE Trans. on
power electron., vol. 22, no. 6, pp. 2307-2320, Nov. 2007.
[A.46] X. Xie, J. Zhang, C. Zhao, Z. Zhao, and Z. Qian, “Analysis and Optimization of LLC
Resonant Converter with a Novel Over-Current Protection Circuit”, IEEE Trans. on power
electron., vol. 22, no. 2, pp. 435-443, Mar, 2007.
[A.47] Y. Gu, Z. Lu, L. Hang, Z. Qian, and G. Huang, “Three-Level LLC Series Resonant DC-
165
Daocheng Huang References
DC Converter,” IEEE Trans. on power electron. vol. 20, no. 4, pp. 781–789, Jul. 2005.
[A.48] K. Yi, G. Moon, “Novel Two-Phase Interleaved LLC Series-Resonant Converter Using a
Phase of the Resonant Capacitor,” IEEE Trans. on Ind. Electron., vol. 56, iss. 5, pp: 1815 –
1819, May 2009.
[A.49] On Semiconductor, "NCP1395LLCGEVB: 240W LLC evaluation board," [online],
available:http://www.onsemi.com/PowerSolutions/evalBoard.do?id=NCP1395LLCGEVB,
Feb, 2006.
[A.50] Texas Instrument, "UCC25600EVM: LLC resonant half bridge converter 300 W
evaluation module," [online], available: http://www.ti.com/lit/ug/sluu361/sluu361.pdf, Apr,
2009.
[A.51] STMicroelectronics, "STEVAL-ISA018V1 demonstration board based on resonant half-
bridge SMPS for industrial applications," [online], available:
http://www.st.com/internet/com/TECHNICAL_RESOURCES/TECHNICAL_LITERATUR
E/USER_MANUAL/CD00238992.pdf, May, 2010.
[A.52] Power Integration, "Reference design report for a 150 W LLC high-voltage DC-DC
resonant converter using hiperLCSTM LCS702HG," [online], available:
http://www.powerint. com/sites/default/files/PDFFiles/rdr239.pdf, Sep, 2011.
[A.53] Infineon, "ICE2HS01G: High performance resonant mode controler," [online],
available:http://www.infineon.com/dgdl/Design+Guide+for+LLC+Converter+with+ICE2HS
01G+05072011.pdf?folderId=db3a304412b407950112b408e8c90004&fileId=db3a304330f6
8606013103ebd94f3e98, May, 2011.
[A.54] NXP Semiconductors, "TEA1713T: Resonant power supply control IC with PFC,"
[online], available: http://www.nxp.com/documents/data_sheet/TEA1713T.pdf, Feb, 2011.
[A.55] Fairchild Semiconductor, "FAN7621: PFM controller for half-bridge resonant
converters," [online], available: http://www.fairchildsemi.com/ds/FA/FAN7621.pdf, July,
2010.
[A.56] Vishay Siliconix ,” Application notes 833: Switching Analysis of Synchronous Rectifier
MOSFETs With Phase-Shifted Full-Bridge Converter and Current Doubler, ”[online],
available: http://www.vishay.com/docs/69747/answitch.pdf, Oct, 2007
166
Daocheng Huang References
[A.57] X. Xie, J. Liu, F.N.K. Poon, M. Pong, “A novel high frequency current-driven SR
applicable to most switching topologies”, IEEE Trans. on Power Electronics, vol. 16, issue. 5,
2001, pp. 635-648.
[A.58] X. Wu, G. Hua, J. Zhang, Z. Qian, “A new current-driven synchronous rectifier for
series–parallel resonant (LLC) DC-DC converter”, IEEE Trans. on Industrial Electronics, vol.
58, issue. 1, 2011, pp. 289-297.
[A.59] International Rectifier, “IR11672AS: Advanced smart rectifier control IC” [Online].
Available: http://www.irf.com/product-info/datasheets/data/ir11672aspbf.pdf.
[A.60] D. Fu, Y. Liu, F. C. Lee and M. Xu, “A Novel Driving Scheme for Synchronous
Rectifiers in LLC Resonant Converters,” IEEE Trans. Power Electron., vol. 24, no. 5, pp.
1321–1329, May 2009.
[A.61] Dianbo Fu; Pengju Kong; Shuo Wang; Lee, F.C.; Ming Xu, "Analysis and suppression of
conducted EMI emissions for front-end LLC resonant DC/DC converters," Power Electronics
Specialists Conference, 2008. PESC 2008. IEEE , vol., no., pp.1144,1150, 15-19 June 2008
[A.62] R. P. Severns, “Topologies for three-element resonant converters,” IEEE Trans. Power
Electron., vol. 7, no. 1, pp. 89–98, Jan. 1992.
[A.63] I. Batarseh, “Resonant converter topologies with three and four energy storage elements,”
IEEE Trans. Power Electron., vol. 9, no. 1, pp. 64–73, Jan. 1994.
[A.64] Dianbo Fu; Lee, F.C.; Ya Liu; Ming Xu, "Novel multi-element resonant converters for
front-end dc/dc converters," Power Electronics Specialists Conference, 2008. PESC 2008.
IEEE , vol., no., pp.250,256, 15-19 June 2008
[A.65] Vicor Corporation, “High-voltage DC distribution is key to increased systemefficiency
and renewable-energy opportunities, ” [online], available:
http://www.vicr.com/documents/whitepapers/wp-High-voltage-DC-istribution.pdf
[A.66] IBM, “A New Redundancy Strategy for High-Availability Power System,” [online],
available: http://www-
03.ibm.com/procurement/proweb.nsf/7a84535a0acd580885256b3f000e250a/3a70bbaee2280
48085257ac20066b558/$FILE/8-A%20New%20Redundancy%20Strategy%20for%20High-
Availability%20Power%20Systems%20(Covi).pdf
167
Daocheng Huang References
[A.67] Vicor Corporation, "From 48 V direct to Intel VR12.0: Saving 'Big Data' $500,000 per
datacenter, per year, "[online]
[A.68] C. Prasantanakorn, "Current sharing method for resonant DC-DC transformers," Master
thesis in Virginia Tech, 2011.
[A.69] U. K. Mishra, P. Parikh, and Y. Wu, “AlGaN/GaN HEMTs – an overview of device
operation and applications,” Proceedings of the IEEE, vol. 90, no. 6, pp.1022-1031, Jun.
2002.
[A.70] M. A. Khan, G. Simin, S. G. Pytel, A. Monti, E. Santi, and J. L. Hudgins, “New
developments in gallium nitride and the impact on power electronics,” in proc. IEEE Power
Electronics Specialists Conference, 2005, pp. 15-26.
[A.71] N. Kaminski, “State of the art and the future of wide band-gap devices,” in Proc. IEEE
Power Electronics and Applications, 2009, pp. 1–9.
[A.72] Y. Wu, M. J. Mitos, M. Moore, and S. Heikman, “A 97.8% Efficient GaN HEMT boost
converter with 300W output power at 1 MHz,” IEEE Electron Device Letters, vol. 29, no. 8,
pp. 824–826, Aug. 2008.
[A.73] W. Saito, T. Nitta, Y. Kakiuchi, Y. Saito, K. Tsuda, I. Omura, and M. Yamaguchi, “A
120-W boost converter operation using a high-voltage GaN-HEMT,”IEEE Electron Device
Letters, vol. 29, no. 1, pp. 8–10, Jan. 2008.
[A.74] W. Saito, T. Domon, I. Omura, T. Nitta, Y. Kakiuchi, K. Tsuda, and M. Yamaguchi,
“Demonstration of resonant inverter circuit for electrodeless fluorescent lamps using high
voltage GaN-HEMT,” in proc. IEEE Power Electronics Specialists Conference, 2008, pp.
3324-3329.
[A.75] W. Chen, K. Wong, and K. J. Chen, “Single-chip boost converter using monolithically
integrated AlGaN/GaN lateral field-effect rectifier and normally off HEMT, ” IEEE Electron
Device Letters, vol. 30, no. 5, pp. 430–432, May. 2009.
[A.76] D. Costinett, H. Nguyen; R. Zane, and D. Maksimovic, “GaN-FET based dual active
bridge DC-DC converter,” in proc. IEEE Applied Power Electronics Conference, 2010, pp
1425-1432.
[A.77] M. J. Scott, K. Zou, J. Wang, C. Chen, M. Su, and L. Chen, “A Gallium-Nitride
168
Daocheng Huang References
[B.1] V. Vorperian ,etc , “A complete DC analysis of the series resonant converter, ” Proc of
PESC, 1982, page 85-100
[B.2] Steigerwald, R.L, “A comparison of half-bridge resonant converter topologies,” Trans of
IEEE, Vol 3, issue 2, 1988, page 174-182
[B.3] J. Chen, etc, “Load Independent AC/DC Power Supply for Higher Frequencies with Sine-
Wave Output,” IEEE Trans. Indus Application, Vol IA-19, Issue 2, 1983, page 223-227
[B.4] Bo Yang, “Topology Investigation for Front End DC-DC Power Conversion for
Distributed Power System," PhD Dissertation, Dept. ECE. Virginia Tech, 2003.
[B.5] G. Huang, A. J. Zhang, and Y. Gu, “LLC Series Resonant DC-to-DC Converter,” U.S.
Patent 6 344 979, Feb. 5, 2002.
[B.6] B. Yang, F. C. Lee, and M. Cancannon, “Over current protection methods for LLC
resonant converter,” in Proc. IEEE APEC, 2003, pp. 605–609.
[B.7] B. Yang, F. C. Lee, A. J. Zhang, and G. Huang, “LLC resonant converter for front end
dc-dc conversion,” in Proc. IEEE APEC, 2002, pp. 1108–1112.
169
Daocheng Huang References
[B.8] B. Yang, Y. Ren, and F. C. Lee, “Integrated magnetic for LLC resonant converter,” in
Proc. IEEE APEC, 2002, pp. 346–351.
[B.9] Bo Yang, “Topology Investigation for Front End DC-DC Power Conversion for
Distributed Power System," PhD Dissertation, Dept. ECE., Virginia Tech, 2003.
[B.10] Y. Gu, Z. Lu, L. Hang, Z. Qian, and G. Huang, “Three-level LLC series resonant DC-DC
converter,” IEEE Trans. Power Electron., vol. 20, no. 4, pp. 781–789, Jul. 2005.
[B.11] R. P. Severns, “Topologies for three-element resonant converters,” IEEE Trans. Power
Electron., vol. 7, no. 1, pp. 89–98, Jan. 1992.
[B.12] Daocheng Huang; Dianbo Fu; Lee, F.C.; , "High switching frequency, high efficiency
CLL resonant converter with synchronous rectifier," ECCE 2009. IEEE , vol., no., pp.804-
809, 20-24 Sept. 2009
[B.13] Weiyi Feng; Lee, F.C., "Optimal Trajectory Control of LLC Resonant Converters for
Soft Start-Up," Power Electronics, IEEE Transactions on , vol.29, no.3, pp.1461,1468, March
2014
[B.14] Dianbo Fu; Lee, F.C.; Ya Liu; Ming Xu; , "Novel multi-element resonant converters for
front-end dc/dc converters," PESC 2008. IEEE , vol., no., pp.250-256, 15-19 June 2008
[B.15] I. Batarseh, “Resonant converter topologies with three and four energy storage elements,”
IEEE Trans. Power Electron., vol. 9, no. 1, pp. 64–73,Jan. 1994.
[B.16] Steigerwald, R.L.; , "A comparison of half-bridge resonant converter topologies," Power
Electronics, IEEE Transactions on , vol.3, no.2, pp.174-182, Apr 1988
[B.17] Dianbo Fu; Ya Liu; Lee, F.C.; Ming Xu; , "A Novel Driving Scheme for Synchronous
Rectifiers in LLC Resonant Converters," Power Electronics, IEEE Transactions on , vol.24,
no.5, pp.1321-1329, May 2009
[B.18] Feng, Weiyi; Huang, Daocheng; Mattavelli, Paolo; Fu, Dianbo; Lee, Fred C.; , "Digital
implementation of driving scheme for synchronous rectification in LLC resonant converter,"
ECCE 2010, vol., no., pp.256-263, 12-16 Sept. 2010
170
Daocheng Huang References
[D.1] G. Huang, A. J. Zhang, and Y. Gu, “LLC Series Resonant DC-to-DC Converter,” U.S.
171
Daocheng Huang References
172
Daocheng Huang References
[E.1] Dianbo Fu; Lee, F.C.; Ya Liu; Ming Xu; , "Novel multi-element resonant converters for
front-end dc/dc converters," PESC 2008. IEEE , vol., no., pp.250-256, 15-19 June 2008
[E.2] Daocheng Huang; Lee, F.C.; Dianbo Fu; , "Classification and selection methodology for
multi-element resonant converters," APEC 2011 IEEE , vol., no., pp.558-565, 6-11 March
2011
[E.3] B. Yang, R. Chen and F. C. Lee “ Integrated Magnetic for LLC Resonant Converter,”
Applied Power Electronics Conference and Exposition, APEC‘OZ, vol. 1, pp. 346 - 351.
[E.4] R. Chen, J. T. Strydom and J. D. van Wyk, “Design of Planar Integrated Passive Module
for Zero-Voltage- Switched Asymmetrical Half-Bridge PWM Converter,” Industry
173
Daocheng Huang References
174