You are on page 1of 28
At a glance
Powered by AI
The document discusses spare parts solutions and renovation options for electrical equipment.

Renovation solutions include switchboard renovation through progressive replacement or addition of cubicles, and switchgear renovation through replacement of old medium and low voltage switchgear.

Equipment goes through different life phases from commercialization to spare parts no longer being guaranteed.

Services & Projects

Spare Parts
Spare parts solutions
General contents

Presentation of the offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Renovation solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product life cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Spare parts, renovation and retrofit solutions . . . . . . . . . . . . 7


MV cubicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Protection device retrofit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LV switchboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
LV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Retrofitting competitors’ devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Life phases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
MV cubicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
MV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
MV protection devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
LV switchboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
LV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

1
Presentation of the offer
Introduction

Every piece of equipment has a risk of failure associated with it. Whilst you can minimise the risk by choosing
high quality products and performing regular maintenance, the risk can never be entirely removed.

By having access to the right spare parts at the right time you can ensure that your equipment is returned to service in
the shortest possible time, avoiding lost revenue and safeguarding your assets and business.

Schneider Electric supply original spare parts for both current and obsolete Schneider Electric electrical distribution
product ranges.

Our team can provide assistance to you in identifying the required parts and can help with the provision of related
catalogues and maintenance manuals. Whether as part of a crash kit or in a central store it’s reassuring to know that
critical spare parts are available to you 24/7.

Benefits:
Increased service life and performance of your customers equipment
• Minimise lost revenue through system downtime
• Part supplied by the original equipment manufacturer
• Parts will perform in accordance with the required duty cycle

Make the most of your energyTM

2
Presentation of the offer
Spare parts and renovation solutions

Scope of the offer


Supply of spare parts
Ensure the supply of spare parts for equipment that is no longer commercialised
by manufacturing departments.
Switchboard renovation
p Progressive replacement without modification of customers’ equipment:
renovation of medium and low voltage switchgear,
kits for improving equipment.
p Complete replacement or addition of cubicles by extension:
insertion of cubicles into the switchboard with connection ducts,
addition at the end of the switchboard of cubicles identical to the initial cubicle,
in accordance with floor space constraints.
Switchgear renovation
Replacement of old medium and low voltage switchgear and protection devices
by retrofit solutions.

Cost-effective solutions to fit your needs


p No break in continuity of service
p No added civil engineering work
p No modification of your equipment
p Operating constraints taken into account
p Progressive renovation to fit your budget

Validated and tested solutions


p Manufacturer’s warranty on renovated equipment
p Factory-validated and tested equipment

3
Presentation of the offer
Product life cycle

There are four major phases in the product life cycle:

Commercialisation period
The product is launched to the market and is included in the Schneider Electric catalogue.
The supply of spare parts is guaranteed.

Guaranteed spare parts supply period


The product is withdrawn from the market.
Schneider Electric continues to supply spare parts for a period of time.
Generally speaking, the average guaranteed spare part supply period
after the end of commercialisation is :
p medium voltage: 12 years
p low voltage power: 10 years
p compact (accessories - devices): 3 years
p electronic equipment: according to the range
When the end of the guarantee period is reached, the product is considered to be expired.

Non-guaranteed spare parts supply period


As of the expiry date, the product is considered to be expired.
Spare part stock and supply are no longer guaranteed after the expiry date.
This period ends on the date on which the spare part offer is ended.

Predicted end of
spare part offer

Expiry

Start of End of
commercialisation commercialisation

Prices and
delivery times

Spare parts Spare parts


End of supply supply
commercialisation guaranteed not guaranteed Time

Switchgear retrofit

Device retrofit period


Commercialisation of a retrofit offer for the replacement of old switchgear and protection devices.
The supply of retrofits will stop at the end of the commercialisation of the new devices used.
The spare parts for these retrofits will therefore be handled as described above.

4
5
Spare parts, renovation
and retrofit solutions
Spare parts, renovation and retrofit solutions
Contents

MV cubicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RM6 range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Vercors VM6 range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Protection device retrofit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

LV switchboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Masterbloc range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Prisma range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Prisma Plus range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

LV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Retrofitting competitors’ devices . . . . . . . . . . . . . . . . . . . . . 17

7
Spare parts, renovation and retrofit solutions
MV cubicles

RM6 range RM6+ monobloc = RM6 1


Commercialisation Spare parts supply Spare parts supply
1988 1999 guaranteed 2011 not guaranteed 2012

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit

RM6 2 monobloc
Commercialisation Spare parts supply Spare parts supply
1988 guaranteed not guaranteed

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit

Legend:
p Offer available
p Offer unavailable

8
Spare parts, renovation and retrofit solutions
MV cubicles

Vercors VM6 range CRM


Commercialisation Spare parts supply Spare parts supply
1975 1993 guaranteed 2008 not guaranteed 2011

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Reworking the original device
Old Cubicle New
width
R400 400 A 12 kV 500 mm R400 400 A 12 kV
R400D R400D

CM / DDM / IM / IMC / NSM / PM / PMC / QM / QMC


Commercialisation Spare parts supply Spare parts supply
1975 1993 guaranteed 2008 not guaranteed 2011

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit

DM2
Commercialisation Spare parts supply Spare parts supply
1975 1993 guaranteed 2008 not guaranteed 2011

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit
Old Cubicle New
width
FB3 400 to 630 A 24 kV 1000 mm SF1 * 400 to 630 A 24 kV

* Offer available in June 2010.

Legend:
p Offer available
p Offer unavailable

9
Spare parts, renovation and retrofit solutions
MV cubicles

Vercors VM6 range DM12


Commercialisation Spare parts supply Spare parts supply
1976 1993 guaranteed 2008 not guaranteed 2011

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit
Old Cubicle New
width
FB4 400 to 1250 A 24 kV 750 mm SF1 * 400 to 1250 A 24 kV

DM22 / DM23
Commercialisation Spare parts supply Spare parts supply
1976 1993 guaranteed 2008 not guaranteed 2011

p Complete cubicle
p Cubicles modification
p Cubicle spare parts
p Retrofit/cubicle interface spare part
p Protection device retrofit (see page 25)
p Switchgear retrofit
Old Cubicle New
width
FB4 400 to 1250 A 24 kV 1000 mm SF1 400 to 630 A 24 kV

* Offer available in June 2010.

Legend:
p Offer available
p Offer unavailable

10
Spare parts, renovation and retrofit solutions
Protection device retrofit

Old protection device made by


Schneider Electric or competitor

Application Applications Application


Busbars Motor, transformer, Generator
substation

No Simple Complex
automation automation automation

Measurement Measurements Measurements


of I or U of I and U of I and U

Sepam Sepam Sepam


series 20 series 40 series 80
Limited to current All types of protection All types
or voltage protection except for differential of protection

New protection

N.B.: protection renovation should also include the complete study


of the LV compartment (diagram, cabling, equipment).

11
Spare parts, renovation and retrofit solutions
LV switchboards

Masterbloc range Masterbloc MB100C


Commercialisation Spare parts supply Spare parts supply
1991 2003 guaranteed 2013 not guaranteed 2014

p Complete column
p Column spare parts
p Module replacement
Masterpact circuit breaker 1250 A, 1000 Vac/Vdc
Masterpact switch-disconnector 1250 A, 1000 Vac/Vdc

Masterbloc MB100M
Commercialisation Spare parts supply Spare parts supply
1991 2003 guaranteed 2013 not guaranteed 2014

p Complete column
p Column spare parts
p Module replacement
Compact circuit breaker 3200 A, 1000 Vac/Vdc

Masterbloc MB200
Commercialisation Spare parts supply Spare parts supply
1988 2003 guaranteed 2013 not guaranteed 2014

p Complete column
p Column spare parts
p Module replacement
Masterpact circuit breaker 6300 A, 1000 Vac/Vdc
Masterpact switch-disconnector 6300 A, 1000 Vac/Vdc
p Adaptation
Compact circuit breaker 1250 A 1000 Vac/Vdc

Legend:
p Offer available
p Offer unavailable

12
Spare parts, renovation and retrofit solutions
LV switchboards

Masterbloc range Masterbloc MB400


Commercialisation Spare parts supply Spare parts supply
1991 2003 guaranteed 2013 not guaranteed 2014

p Complete column
p Column spare parts
p Module replacement
Masterpact circuit breaker 3200 A, 1000 Vac/Vdc
Masterpact switch-disconnector 3200 A, 1000 Vac/Vdc
p Rack replacement
Compact circuit breaker 630 A, 1000 Vac/Vdc
Interpact circuit breaker 630 A, 1000 Vac/Vdc
Contactor 500 A, 1000 Vac/Vdc

Prisma range G / GK / GX / GR / P / PH / UT
Commercialisation Spare parts supply Spare parts supply
1988 2004 guaranteed 2014 not guaranteed 2015

p Complete switchboard
p Switchboard spare parts

Prisma Plus range G system / P system / P cubicle


Wall-mounted P / Floor-standing G
Wall-mounted Pack
Commercialisation Spare parts supply Spare parts supply
2003 guaranteed not guaranteed

p Complete switchboard
p Switchboard spare parts

Legend:
p Offer available
p Offer unavailable

13
Spare parts, renovation and retrofit solutions
LV switchgear

Low-rating Selpact
Commercialisation Spare parts supply Spare parts supply
1973 1989 guaranteed 1998 not guaranteed 2009

p Device spare parts


p Retrofit/switchboard interface spare part (**)
p Device manufacturing
Withdrawable low-rating Selpact p Device repairing
p Switchgear retrofit
Corresponding functions: fixed V fixed with pad
fixed V withdrawable with pad
withdrawable V withdrawable with pad
withdrawable V withdrawable with truck
Old: low-rating Selpact New: Masterpact
Type Isc (kA) In (A) Type Isc (kA) In (A)
DN2 50 630/1000 NT H2 50 630/1000
DR2/DRS2 100 630/1000 NT L1 150 630/1000
Withdrawable truck type Masterpact NT DS2 45 630/1000/1250 NT H2 50 630/1000/1250

High-rating Selpact
Commercialisation Spare parts supply Spare parts supply
1973 1989 guaranteed 1998 not guaranteed 2009

p Device spare parts


p Retrofit/switchboard interface spare part (**)
Withdrawable high-rating Selpact p Device manufacturing
p Device repairing
p Switchgear retrofit
Corresponding functions: fixed V fixed with pad
withdrawable V withdrawable with pad
withdrawable V withdrawable with truck (*)
Old: high-rating Selpact New: Masterpact
Type Isc (kA) In (A) Type Isc (kA) In (A)
DN2/DS2 50 1600 to 3200 NW H1 65 1600 to 3200
DN2H/DS2H 70 1600 NW H2 100 1600
Withdrawable truck type Masterpact NW
80 2000 to 3200 NW H2 100 2000 to 3200

(*) 1600 A only.


(**) Truck solution only.

Legend:
p Offer available
p Offer unavailable

14
Spare parts, renovation and retrofit solutions
LV switchgear

DA
Commercialisation Spare parts supply Spare parts supply
1968 1990 guaranteed 1998 not guaranteed 2009

p Device spare parts


p Retrofit/switchboard interface spare part
p Device manufacturing
p Device repairing
p Switchgear retrofit
Corresponding functions: fixed V fixed with pad
withdrawable V withdrawable with pad
Old: DA New: Masterpact
Type Isc (kA) In (A) Type Isc (kA) In (A)
DNA1 70 1600/2000 NW H2 65 1600/2000
100 2500/3200 NW H2 100 2500/3200
100 4000/5000 Please consult us
DNA2 45 630 to 1250 NW H1 65 800 to 1250
50 1600 to 2500 NW H1 65 1600 to 2500
DNAH 100 1600/2000 NW H2 100 1600/2000
DRA 100 630 to 2000 NW H2 100 800 to 2000
DSA1 50 800 to 1250 NW H1 65 800 to 1250
60 1600/2000 NW H1 65 1600/2000
85 2500/3200 NW H2 100 2500/3200
85 4000 Please consult us
100 5000 Please consult us
DSA2 35 800 to 1250 NW N1 42 800 to 1250
45 1600 to 2500 NW H1 65 1600 to 2500

Compact
Commercialisation Spare parts supply Spare parts supply
1981 1997 guaranteed 2000 not guaranteed 2002

p Device spare parts


p Retrofit/switchboard interface spare part
p Device manufacturing
p Device repairing
p Switchgear retrofit
Old: Compact New: Masterpact
Type Poles Function In (A) Type Poles Function In (A)
C1250 STC 3 P Withdrawable 1250 NT Please consult us

Legend:
p Offer available
p Offer unavailable

15
Spare parts, renovation and retrofit solutions
LV switchgear

Masterpact
Commercialisation Spare parts supply Spare parts supply
1986 2003 guaranteed 2005 not guaranteed 2014

p Device spare parts


p Retrofit/switchboard interface spare part (*)
p Device manufacturing
p Device repairing
p Switchgear retrofit
Old: Masterpact M New: Masterpact NW
Type Poles Function In (A) Type Poles Function In (A)
M 3P Withdrawable 800 to 3200 Plug and Play 3 P Withdrawable 800 to 3200
Fixed/ 800 to 6300 Masterkit 3P Fixed/ 800 to 6300
Withdrawable Withdrawable
4P Withdrawable 800 to 3200 Plug and Play 4 P Withdrawable 800 to 3200
Fixed/ 800 to 6300 Masterkit 4P Fixed/ 800 to 6300
Withdrawable Withdrawable

Plug and Play solution


The Masterpact NW can be mounted in the Masterpact M frame.
The Plug and Play solution consists of:
p a Masterpact that has been adapted and fitted with special power connections
p a fine wire cross-member
p a pair of corresponding drawers.

Masterkit solution
Complete Masterpact M replacement kit.
The kit consists of:
p Masterpact NW
p power connections according to rating
p frame, in the case of a withdrawable device
p attachment bracket, in the case of a fixed device
p wire bundle
p insulating plate
p door faceplate
p screw kit.
(*) Plug and Play solution only.

Legend:
p Offer available
p Offer unavailable

16
Spare parts, renovation and retrofit solutions
Retrofit

Enhanced equipment performance with minimal interruption


Schneider Electric offer retrofit solutions for various medium voltage and low voltage devices installed in the world
today.

Why retrofit?
Retrofitting allows you to extend the life of your power distribution without the disruption of physically removing and
replacing your entire switchboard and disturbing existing cabling.

It will also improve your installation’s efficiency through the use of the latest available technology.
Dependent on the device to be retrofitted, Schneider Electric can offer several solutions:

MV Retrofit
• Schneider Electric have designed a retrofit solution to extend the operational life of its YSF6 range
of withdrawable switchgear, introducing a “roll-out” “roll-in” retrofit offer which replaces the SF6 circuit breaker with
our latest Evolis vacuum circuit breaker in a new moving portion. In addition certain other device ranges also
covered.

Applicable Panels
Panel type Feeder, Incomer & Bus-section
Nominal current 630A/1250A
Highest system voltage 12kV
Rated voltage 11kV
Service voltage 3.3, 6.6 &11kV
Rated BIL 75kV (95kV available shortly)
Rated breaking capacity 25kA

Low voltage Retrofit


• LV engineered solutions - A custom made solution using either pre-engineered components, on-site fabrication
or a combination of both
• LV kitted retrofits - This solution applies mainly to Merlin Gerin devices, where kit for the entire device is available
enabling simple installation on site without the need for fabrication. This is also available for Klockner Moeller IZM
devices
• LV plug and play - An innovative solution developed exclusively for Schneider Electric Masterpact M and Klockner
Moeller IZM circuit breakers. The original chassis is retained, allowing the retrofit to be completed in less than one hour,
with minimal disruption.

ACBs and MCCBs that can be replaced • Mitsubishi


• Siemens
• All Merlin Gerin devices, Masterpact, • AEG
DA, Selpact, Compact • Vickers
• Ottermill • GEC
• Ellison • Other manufacturers by consultation
• Terasaki
• ABB/SACE

For further information on retrofit solutions please consult our publication SE6905 for medium voltage and low voltage
retrofits.

17
Life phases
Life phases
Contents

MV cubicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

MV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

MV protection devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

LV switchboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

LV switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

19
Life phases
MV cubicles

Commercialisation Spare parts supply Spare parts supply


Cancelled range guaranteed not guaranteed
RN2 1991 2000
IVI, IVIF, IVIO 1959 1974 2010
Cancelled

SO-HI 1974 1990 2000 2010


range

TYKE, TYKE IIA 1974 1990 2000 2010


FSA 1974 1990 2000 2010
OSA 1974 1990 2000 2010
VM6 1975 1993 2008 2011
SM6 1993
RM6 (+) 1988 1999 2011 2012
RM6 2 1988
YSF6 1981 2001
Genie SF6 1996 2004
Available
range

Genie Evo 2003


RN2c, RN6c, RE2c 2000
CN2 1994
SN6 1994
MU2 1994
CE2 1994
CE6 1994
SE6 1994

For other MV cubicles, please consult us.

20
Life phases
MV switchgear

Commercialisation Spare parts supply Spare parts supply


Switch-disconnectors - guaranteed not guaranteed
Disconnectors
Intersec G/Intersec K R 1966 1980 1988 1988
Cancelled

Lamisec R 1960 1980 1988 1988


range

FU/FUC/FUCO R 1980 1985 1995 1995


Isolarc 1985 1998 2008 2009
M2S 1990 1999 2019
Available
range

PM6 (old version) 1990 1999 2019

Commercialisation Spare parts supply Spare parts supply


Contactors guaranteed not guaranteed
K/KD R 1958 1972 1984 1995
KA/KDA R 1973 1979 1991 1995
Cancelled

C/CD R 1960 1972 1984 1995


range

C1/CD1 R 1973 1986 1998 2001


Rollarc 100/100D R 1977 1984 1996 1996
Rollarc 200/200D R 1977 1980 1992 1992
Rollarc 400/400D 1980
Available
range

CTV 1 2005

Commercialisation Spare parts supply Spare parts supply


Circuit breakers guaranteed not guaranteed
DST R 1955 1971 1983 1990
DIS R 1960 1980 1992 1998
DSE (except for Furnace and 22 G/K) R 1972 1986 1998 2001
DSE Four R 1971 1979 1991 1995
DSE 22 G/DSE 22 G K R 1977 1980 1992 1995
Cancelled

FA3 R 1972 1974 1986 1986


range

FB3 1972 1982 1994 2004


FB2 R 1972 1982 1990 1991
FC R 1975 1988 2000 2000
FB4 1976 1996 2008 2009
FG3 R 1986 1998 2009 2009
FG4 R 1986 1998 2009 2009
F3 1972 1982 1998 2010
FG1 R 1980 1998 2010 2011
FG2 R 1980 1998 2010 2011
FBM (before 1997) R 1980 1997 2009 2010
Available
range

FBM (after 1997) 1997


SF 1/ SF 2 1990
LF 1/LF 2/LF 3 1995
LFP 1996
DV 2 2000
DV 4 2004

For other MV switchgear, please consult us.

Legend:
R: there is a retrofit solution.

21
Life phases
MV protection devices

Commercialisation Spare parts supply Spare parts supply


Protection relays guaranteed not guaranteed
THR (before 1988) 1988 1994 1995 1996
THR (after 1988) 1989 1994 1995 1996
Sepam 10 1986 1988 2000 2000
Sepam 15 1987 1996 2002 2002
Sepam 1000 1993 2000 2005 2005
Vigirack 1960 1996 2000 2001
Cancelled

RV110 1977 1984 2004


range

RV111 1977 1984 2004


RAH411 E (before 06/93) 1979 1991 2004
RVH213 B 1973 1981 2004
RNS11 vertical 1973 1993 1994 2004
VIP11/VIP12 1990 2003 2008 2009
VIP13 1994 2005 2008 2009
VIP17 1994 2000 2001 2007
Self-powered protection PA 1998
RV112 1984 2007
RAH410 E 1977 1979
RAH411 E (after 06/93) 1993 2007
RVH215 B 1981 1994
RVH215 L 1992 1995
RVH215 I 1981 2003
RNS11 horizontal 1995 2007 2008 2015
Available

RCV420 1973 2007 2008 2015


range

RH110 1978 2007


THR nuclear 1988
VIP37 2000
VIP30/VIP35 1996
VIP50 1998
VIP200/VIP201 1989 2005
VIP300 LL/VIP300 LH 1997
VIP300 P 2004
Vigirack nuclear 1970

For other MV protection devices, please consult us.

22
Life phases
LV switchboards

Commercialisation Spare parts supply Spare parts supply


guaranteed not guaranteed
Prébloc 1949 1974 1984 1990
Murbloc 1962 1974 1984 1984
Mécabloc 1959 1974 1982 2001
Cancelled

Visibloc 1968 1974 1982 1995


range

T12 column 1972 1980 1990 2003*


CM 14 1972 1976 1988 1996
P6 1974 1984 1994 1994
T140 column *** 1975 1990 1998 2005
P12 plug-in (with socket) 1972 1982 1992 2010
T12 racks *** 1972 1980 2006 2010
T140 racks *** 1975 1990 1998 2014
TM7/TD8/TD9/TDS 1967 1995
Masterbloc MB200 ** 1988 2003 2013 2014
Masterbloc MB100 * 1991 2003 2013 2014
Available
range

Masterbloc MB400 racks *** 1991 2003 2013 2014


Prisma 1988 2004 2014 2015
Prisma plus 2003
TDI 1986
TMD 1975
TMI 1987
Prefabricated busbar trunking * 1980 2004 2014 2015
Normabarre enclosures

For other LV switchboards, please consult us.


(*) Switchboard parts available.
(**) Switchboard parts available + device adaptation kit.
(***) Fixed and moving parts of racks.

23
Life phases
LV switchgear

Commercialisation Spare parts supply Spare parts supply


Circuit breakers - contactors guaranteed not guaranteed
DSG/DMG R 1950 1975 1984 1996
DMC/DMP/DRC/CI/DC/DCR 1950 1966 1986 1998
DA (before 1968) R 1963 1968 1974 1995
CM Complete device 1981 2003 2005 2005
Cancelled

STCM 1981 2003 2006 2006


range

Spare parts 1981 2003 2006 2006


Masterpact M Complete device R 1986 2003 2005 2006
DA (after 1968) Low rating R 1968 1986 1998 2009
High rating R 1970 1990 1998 2009
Selpact R 1973 1989 1998 2009
Masterpact M STR 1986 2003 2008 2013
Available
range

Pièces de rechange 1986 2003 2013 2014

Commercialisation Spare parts supply Spare parts supply


Compact guaranteed not guaranteed
Interpact Int 40/63/100/125/160 1981 1999 2005 2005
IN250/IN400/IN630 1985 2001 2005 2005
Dialpact 1993 1999 2003 2003
Cancelled

Visucompact 1985 2001 2005 2005


range

C1250 STC Complete device R 1981 1997 2000 2002


C125/C161/C250 NHL
C400/C401/C630 NHL
C1250 STC Compact accessories 1981 1997 2000 2007
(coil, contact…)
C125/C161/C250 NHL Compact accessories 1981 1997 2000 2009
C400/C401/C630 NHL (coil, contact…)
DB 33 Navy 1993 1998 2009 2010
Available

C801/C1001/C1251 NHL 1993 2006 2008


range

NS 1993
C800/C1000/C1250 1981 1998

For other LV switchgear, please consult us.

Legend:
R: there is a retrofit solution.

24
Nationwide support on one number -

0870 608 8 608


Fax 0870 608 8 606
Schneider Electric, the global specialist in energy management,
offers integrated solutions making energy safer, more reliable,
efficient and productive in the energy and infrastructure, industry,
data centres and networks, buildings and residential markets.

With sales of €18.3 billion in 2008, the company’s 114,000 employees in 102 countries
help individuals and organisations make the most of their energy.

We are changing our brand names and becoming one Schneider Electric.
You’ll get the same great quality products, but from one name you can remember and
trust. This provides you and your customers with the reassurance associated with
Schneider Electric.

Some of our market leading brands have already become Schneider Electric including
Merlin Gerin, Telemecanique, Mita, Sarel, Himel, Thorsman, Tower and TAC.

Working as one Schneider Electric makes it clearer that our ranges are highly compatible
for integrated solutions.

Schneider Electric Ltd

United Kingdom Ireland


Stafford Park 5, Head office, Block a
Telford Maynooth Business
SE6876 JUN 2010

Shropshire Campus
TF3 3BL Maynooth, Co. Kildare
Tel: 0870 608 8 608 Tel: (01) 601 2200
Fax: 0870 608 8 606 Fax: (01) 601 2201 As standards, specifications and designs change from time to time,
www.schneider-electric.co.uk www.schneider-electric.ie please ask for confirmation of the information given in this publication

member of
FSC logo
.co.uk

You might also like