REFINERY SHIFT MANAGER HANDOVER REPORT

RSM On Duty: Shahrul


Azhar Ahmad IB Date/Time: 01-Jul-08 06:59 Shift: 1930
1930~0730
~ 0730 hrs Shift Group: B C

UNIT 11: CDU (SOL 120%)


3
Crude Section: Total Feedrate: 672 m /hr 101,425 BPSD 135% Condensate Sec: Total Feedrate: 186 m3/hr 28,131 BPSD 113%
P-1101/1135/1102 Ratio: 60 / 40 Tank Dropped: 100,529 BPSD BNC (06) Cond. Ex. FC501: 93 m3/hr Tank Dropped: 27,598 BPSD
3
Tapis (07) Crude Ex. P1101: 361 m /hr C1101: Load: 748 m3/hr BNC (06) Cond. Ex. FC502: 93 m3/hr
Tapis (01) Crude Ex. P1135: 176 m3/hr O/H T: 125 °C C-1151 Inlet T(ºC): 121 Press: 1.48 kg/cm2 Yields (MBPSD) Naptha- 47
Crude Ex. P1102 135 m3/hr Press: 1.26 kg/cm2 O/H Temp(°C): 75 RMPCT Uptime (%) Kero 29
Desalter Press. : 18.6 kg/cm2 P1101A Speed : 65 % F1101 : Ex O2 % 1.7 CIT(°C): 185 COT(°C): 346 CDU: 0 Diesel 34
P1101B Speed : 0 % F1151 : Ex O2 % 2.5 CIT(°C): 203 COT(°C): 224 CND:Tag not foundLSWR 22
Product m³/hr Lab Results Product m³/hr Lab Results Total 131
Isopentane 21 RVP 188 iC5 vol.% 78 Dens. 0.6158 Light Kerosene 68 Flash 31.5 Freeze -60.0 GC-5 146.1 GC-FBP 190.0
Light Naphtha 86 RVP 83.8 D86-IBP 37.4 Dens. 0.6616 SR Kerosene 125 Flash 51.0 Freeze -39.0 GC-FBP 278.2
Med. Naphtha 132 GC-IBP 89.8 GC-FBP 144.9 C5 0.0 LtKero to Tankage 10
Cond. Naphtha 70 GC-IBP 81.9 GC-50 104.9 GC-FBP 171.9 SR Diesel 1 213 Calc-90 348.5 SIM-90 374.5 Calc-95 366.6 SIM-95 393.0
Cond Tower Btm 44 Flash 75.0 Pour 12.0 Sulfur 0.055 Color 1.0
LSWR 144 Flash 162 Pour 48 Temp(°C) 75 SR Diesel 2 11 Flash 99.5 Pour 15.0 Sulfur 0.055 Color 1.0
Remarks: Diesel jumpover line maintain commissioned to diesel stripper.
Condensate tank switched to T7106.

Excess MSRN maintained to T-72202.


UNIT 14/15/16: SGCU/SWSU/HN&KTU
Product m³/hr % Lab Results
LPG ex CDU1: 12 m³/hr LPG 21 73 C1+2 0.0 C3 12.8 C4 86.2 C3+C4 99.0 C5+6+ 1.0 Cu Corr 1a
LPG ex CFU 9 m³/hr Butane 0 %C4 98 MRU Hg (in/out) 24-Jun 0.52 0.24 ppb
LPG ex CRU: 4 m³/hr Treated Kero 120 95 Color 30 TAN 0.006 Freeze -39.0 PM 0.3
14 Combined Kero 178 LtKero to Combined 58 Flash 40.5 Freeze -47.5
Remarks: Unit Steady

UNIT 12/13: NHT/CRU/CCR (SOL 120%)


NHT: Feedrate: 165 m³/hr 24,281 BPSD 121% R1201 RIT-°C: 318 ROT(°C): 319 Delta T(°C): 1.0 V1202 Press: 28.0
CRU Feed - N2: 0.1 ppm(wt) Total S: 425 ppb(wt) WAIT: 517.8 REQ. WAIT: 509.7 Rx Total dT : 284.9 °C
CRU: Feedrate: 177 m³/hr 23,777 BPSD 119% Reactor R1305 R1306 R1307 R1308
V1301 Press: 5.1 kg/cm² H2 Production: 44,978 Sm³/hr RIT(°C) 514.5 517.2 519.4 518.1
Recycle Gas: Flow(Nm³/hr): 40,934 H2 Purity: 83.8 ROT(°C) 392.5 437.5 465.4 489.0
Moisture: 5.9 ppmV HCl: 2.0 H2S: 1.2 Delta T(°C) -122.0 -79.7 -54.0 -29.1
Reformate: 131 m³/hr RON Lab/Analyzer: 100.2 97.9 RVP 41.0 kPa Distillation IBP 48.8 50% 115.5 FBP 187.9 °C
LPG: 4 m³/hr Furnace Excess O2 %: F1201 2.9 F1202 4.2 F1301 1.2 F1302 1.5 F1303 1.3 F1304 1.9 F1305 6.4
CCR: Unit Status: White Burn Circ. Rate: 966 pph Excess O2: 0.70 % Air/N2 Flow: 114 Sm³/hr
Spnt Cat: Coke: 29-Jun 2.63 wt% Cl2: 29-Jun 1.01 wt% Regen Cat: Coke: 29-Jun 0.06 wt% Cl2: 29-Jun 1.03 wt%
Inferential value: 2.60 wt% RMPCT Uptime: CRU: 100 % CCR 100 % V1309 Cl2: Inlet: 1.5 Outlet: 0.0
Remarks:
LPG ex U13 route, still to flare.

UNIT 21: CDU/VDU (SOL 135%)


3
Current Feedrate: 943 m /hr 140,232 BPSD Tank Drop 140,956 BPSD 141% VDU Feedrate: 597 m³/hr 75,301 BPSD 121%
3
Average 24hrs: 913 m /hr 135,730 BPSD . 0 104 LSWR 45 m³/hr 6,789 BPSD
Crude Charge Pumps P-71201 A, B, C, D , E Feed Tanks: T-71201/02/04/07 Crude Ratio: (Slop/lswr/Rdg/Alt)+(DAR)+(DUB/UZK)+(S/DU/AHY/UZK/SL) =24+16+80+20
F21201: Ex O2 % 2.5 CIT(°C): 258 COT(°C): 348
F21251: Ex O2 % 3.7 CIT(°C): 340 COT(°C): 384 WHB: 17.5 T/hr RMPCT Ctrl Uptime: CDU 2: 100% VDU: 100%
Product Flow (m³/hr) Lab Results Product Flow (m³/hr) Lab Results Yields (MBPSD)
Naphtha 189 Density 0.718 GC86-90 160 HVGO 80 Color 5.5 SIM-90 554.0 O/H Dist 27
Kerosene 111 Flash 45.0 Freeze -48.0 RS-H 85.4 Asp-tene 40 SIM-FBP 608.0 Kero 14
LGO 205 Sulfur 1.15 SIM-90 388.0 CALC-90 362.5 xHVGO 8 Density 0.985 Asp-tene 3769 Diesel 40
HGO 17 Color 4.5 Asp-tene 5 GC86-95 446.3 Vac Resid 190 SIM-10 551 SIM-FBP 747 VGO 36
LVGO 92 Sulfur 1.84 SIM-90 402.5 GC86-90 374.3 Asphalt 0 Density 1.053 Asp-tene 11193 VR 27
MVGO 146 Asp-tene 20 SIM-90 513.0 SIM-FBP 600.0 CRU2 Naphtha 277 m³/hr DHT Sour Diesel 336 m³/hr Total 144
Remarks: HGO still route to DHT as per planning, due to diesel volume committment.
SCR-1 aircond unit chiller found water ingress causing electricals short, now Service Master still attending. Rack room temperature under control.

UNIT 24/26/27/28: SGRU/LTU/NTU/KTU


LPG ex U 23: 5 m³/hr Product m³/hr % Lab Results
LPG ex U 32: 12 m³/hr LPG 29 52.3 C1+2 0.30 C3 44.78 C4 54.77 C3+C4 99.55 C5+6+ 0.15 C3(=) 4.08
LSRN ex U 11: 0 m³/hr IC5 23 22.5 Volatility°C -0.5 Resid 0 Cu Corr 1a Sulfur 24
Offgas ex U 30: 2,739 Nm³/hr IC5 to bullet/Tank 4.5 18 R-SH 1.9 Doc T Negative RVP lab (kpa) 199.5 RVP(kpa) 01-Jul 200
Naph U32 to U22: 26 m³/hr Heavy Naphtha 193 HN to U-22: 193 m³/hr Butane 3.3 m³/hr
RMPCT Ctrl Uptime: 100% Treated Kero 111 121 Color 13 TAN 0.01 Sulfur 0.31 PM 0.65 R-SH 12
Remarks: Butane draw 3.0 m3/hr as per planning.

07/01/2008, 7:17 AM, Page 1 of 3


UNIT 22/23: NHT/CRU/CCR (SOL 120%)
NHT: Feedrate: 249 m³/hr 35,134 BPSD 100% RIT/ROT/DT°C/DP: 290.5 315.2 24.7 0.4 Sep Press 51.4 DH O/H RVP 65.0
RMPCT Ctrl Uptime(NHT/CRU):100% 100% WAIT: 517 °C REQ. WAIT 517.4 Rx Total dT : 256.2 °C
CRU: Feedrate: 218 m³/hr 29,724 BPSD 114% Reactor R23201 R23202 R23203 R23204
Sep Press: 2.5 kg/cm² Net Gas A 0 B 84 C 82 RIT(°C) 518.4 517.8 518.4 516.1
Recycle Gas: 71,261 Nm³/hr H 2 Purity: 87.4% ROT(°C) 401.4 452.6 473.3 487.1
Moisture: 1.95 ppmV HCl: 8.0 H2S: 2.0 Delta T(°C) -117.0 -65.2 -45.0 -29.0
Reformate: 171 m³/hr RON Lab/Analyzer: 98.8 n/a RVP 34.0 kPa CRU Feed - N2: 0.1 ppm(wt) Total S: 401 ppb(wt)
LPG: 5 m³/hr C2-: 3.43 % C3: 28.97 % C4: 67.24 % C5: 0.33 % Rec.+ -11 °C Regen Blower 78,483 Nm³/hr
Furnace Excess O2 %: F22201 2.3 F22202 1.8 F22203 2.1 F23201 2.6 F23202 2.3 F23203 2.5 F23204 2.0
CCR: Unit Status: White burn Circ. Rate 79.9 % 1198.3 pph Excess O2 : 1.05 % Air/N2 Flow: 524 Nm³/hr
Spnt Cat: Coke: 30-Jun 5.27 wt% Cl2: 30-Jun 5.27 wt% Regen Cat: Coke: 30-Jun 0.04 wt% Cl2 27-Jun 1.14 wt%
Remarks: Unit steady. RON target: 98 min.
Feedrate incresed at 29.5 MB.
Both MSRN and U24 naphtha maintained to T-72202.

UNIT 25: C6-ISOM (SOL 120%)


Fresh Feed: 50 m³/hr 7,548 BPSD DIH Recycle: 80 m³/hr Combined Feed: 114 m³/hr 17,033 BPSD Rx Load: 94%
Hydrogen Make-up: 2737 Nm³/hr Isomerate: 44 m³/hr
Moisture Analyzer Reactor Temp Avg Inlet(°C) Avg Outlet(°C) Delta T(°C) RON RVP(kPa)
Gas Dryer Outlet Liq Dryer Outlet Feed C5's C7+ X-Fact R-25201A - LAG 130.2 147.4 17.2 DIH O/H 90.2 100.0
-0.4341 ppmV 0.0375 ppmwt wt% 7.9 0.1 8.5 R-25201B - LEAD 168.0 177.8 9.8 Isom 86.7 80.0
Remarks: Unit steady.

UNIT 29: DHT (SOL 115%)


Feedrate: 270 m³/hr 37,225 BPSD 106% DHT Bypass: 66 m³/hr 10,039 BPSD T-7520 8261 mm Feed / R/D
F29201: Excess O2 % 3.3 CIT(°C): 244 COT(°C): 320 WABT: 341 °C RMPCT Ctrl Uptime: 100% T-7521 2083 mm -
Hydrogen Make-up(Nm³/hr): 13,440 HP Separator Press(kg/cm²): 45.7 Reactor Temp Avg Inlet(°C) Avg Outlet(°C) Delta T(°C)
LP Separator Press(kg/cm²): 21.0 Stripper O/H Temp(°C): 141 Press: 4.6 1st bed 322.0 325.3 3.3
Dryer 1 & 2 vacuum(kg/cm²): -0.30 -0.89 Amine circulation rate: 69 m³/hr 2nd bed 328.4 349.6 21.2
Treated Distillate Sulfur: 0.064 Moisture 108.28 Flash 87 Color 0.5 SIM-95 408 3rd bed 344.4 352.0 7.7
Remarks: Unit steady. Sulfur target: 0.1 wt.%. Feed increased at 37 MB based on H2 availability, LGO bypass at 10MB.

UNIT 30: HCK (SOL 135%)


MVGO ex U21: 2 m³/hr Cold: 196 m³/hr T-72205 16396 mm - Total: 262 Sm³/hr (compensated) 39,572 BPSD 139%
HVGO ex U 21: 66 m³/hr T-72206 15418 mm Feed & r/d 298 Sm³/hr (uncompensated) % Conversion
st nd rd th th
Reactor Feed H2 Inlet P dP RIT ROT Delta T 1 dLAT 2 dLAT 3 dLAT 4 dLAT 5 dLAT Total dLAT CAT Calculated 92
1st Stage 298 184440 180.4 3.9 369.0 424.2 55.2 14.3 23.0 16.0 19.6 21.0 99.3 409.5
2nd Stage 207 104498 178.2 2.6 363.5 380.9 17.4 9.8 7.6 4.9 4.6 28.2 376.2
Product m³/hr Lab Results Product m³/hr Lab Results
Unstab Naphtha 22 Density 0.653 Premium Diesel 126 Flash 78.0 Pour -30.0 Calc-90 334.1 Calc-FBP 354.2
Stab Naphtha 58 Density 0.726 RVP 53 GC86-90 140.7 S-ppm 0.4 Density 0.8223 SIM-90 358.0 SIM-FBP 406.5
Kerosene 44 Flash 42.5 Freeze -70.0 Smoke 27.0 Heavy Diesel 19 Flash 85.0 Pour 15.0
Furnace Excess O2 %: F30210 3.4 F30220 6.4 F30250 5.4 Unconverted Oil 18 Calc-90 378.2 SIM-90 412.0 Calc_FBP 387.1 SIM-FBP 436.0
Make-up H2: 81,214 Nm³/hr Recycle Gas: Flow: 340,537 Nm3/h Feed Properties: MVGO HVGO COMBINED FEED Asp-tene 0.01 Density 0.923
System Press: 170.9 kg/cm² Purity: 96% N2 (ppm) 26/03/08 1125 1458 Ni 0.16 N2 1125
RMPCT Ctrl Uptime:Rxt1/ Rxt2/Frac: 100% 100% 100% Ni (mg/kg) 0.1 0.4 V 0.26 Sulfur 2.14
V (mg/kg) 0.2 0.5 Metal 1.18 Color 6.0
Remarks: Stabilised Naptha still route to PCN tank T-7502.

UNIT 31: HCDS


H2 Sources(Nm3/hr): U 13: 34,356 U 23: 50,258 U 29: 9 U 30: 9,978 U 39: 9,941 H2 Usage(Nm 3
/hr): U30: 81,214 U29: 13,440
PSA In: 92,987 104% H2(ePSA): 81,243 Purity % 30-Jun 98.97 PSA: 10 beds LP Comp(K31201): A 102 B 0 C 99
3
PSA H2 Recovery : 88 % Flare Flow 1/2 (Nm /hr): 2,615 7,735 HP Comp(K31203): A 98 B 57 C 100
Excess H2: -3470 Valve OP to FG (PSR 2): 0 % Flare -5 % Valve OP to FG (PSR 1): 9 % Flare -5 %
Remarks: Unit steady.

UNIT 32: DCU/DCLEU (SOL 122%)


CurrentFeedrate: 185 m³/hr 24,520 BPSD 117% RMPCT Ctrl Uptime: Frac/Heater/LEU: 0% 3% 100% T-72208 8063 mm Rundown
Last24hrsFeedrate: 185 m³/hr 24,552 BPSD F32201: Ex O2 % 2.6 CIT(°C): 270 COT(°C): 491.9 T-72209 18315 mm Feed
HCGO Recycle rate: 5 m³/hr Coke drum Inlet Temp(°C) Outlet Temp(°C) Delta T(°C) Remark
Green Coke Production: 903 T/cycle Sulfur: - wt% V32201 482.2 421.0 -61.2 Online
FZGO R/D Temp: 70 °C V32202 53.8 355.8 302.0 Quenching
Product m³/hr Lab Results Product m³/hr Lab results
Coker Naphtha 26 Density 0.719 C4- 0.0 GC86-90 146.8 HCGO 0 Density 0.899 Sulfur 2.68 MCR 0.10
Coker Distillate 73 Flash 30.0 Pour -9.0 Calc-90 337.3 SIM-90 357.5 FZGO 41 Flash 68.0 Pour 39.0 Sulfur 3.2
LPG 12 C1+2 0.4 C3 58.5 C4 40.3 C3+C4 98.8 C5+6+ 0.8 iC5+nC5 0.4 RVP 878.10 Density 0.543
Remarks: Unit steady.

UNIT 39: HPU (SOL 119%)


Fresh NG: 3,629 Nm³/hr Rec Gas Flow: ####### Nm³/hr Reformer Feed: 3,822 Nm³/hr Steam rate: 10,422 kg/hr Mole Ratio: 3.31
Reformer Inlet/Outlet T(°C): 399.5 774.8 CH4 Analyser: 7.1% Shift Converter Inlet/Outlet T(°C): 351.1 401.4 H2 Production: 10052 Nm³/hr 66%
PSA H2 Recovery: 95 % F39201 Excess O2 % 7.1 H2 Purity: 99.57 %
Remarks: HPU1: Maximum rate.
HPU2: Tripped on steam inlet flow during heavy rain. Re-started.

07/01/2008, 7:17 AM, Page 2 of 3


UNIT 33: ARU
Train 1: Feedrate: 162 m³/hr; 59% O/H Temp(°C): 104 Btm Temp(°C): 125 Reflux(m³/hr): 7 Acid Gas(Nm³/hr): 3653
Lean Amine: Strength (RFB): 30-Jun 32 wt % Amine Flow(m³/hr) to: HCK Rec Gas: 65 HCK Offgas: 13 DHT: 69
H2S: 30-Jun 0.012 wt %

Train 2: Feedrate: 94 m³/hr; 76% O/H Temp(°C): 110 Btm Temp(°C): 124 Reflux(m³/hr): 4.4 Acid Gas(Nm³/hr): 1866
Lean Amine: Strength (RFB): 30-Jun 32 wt % Amine Flow(m³/hr) to: SGRU: 35 LTU: 25 DCU: 36
H2S: 30-Jun 0.008 wt %
Remarks: Unit steady.

UNIT 34: SWTU


Train 1: Feedrate: 45 m³/hr; 81% O/H Temp(°C): 102 Press(kg/cm²): 0.34 Sour Gas(Nm³/hr): -125 34PC003.OP 47 %
Stripped Water: 44 m³/hr; R/d Temp(°C): 41 pH: 27-Jun 5.6 H2S: 27-Jun 0.09 ppm NH3 27-Jun 18.0 ppm

Train 2: Feedrate: 35 m³/hr; 64% O/H Temp(°C): 81 Press(kg/cm²): 1.64 Sour Gas(Nm³/hr): 932 34PC203.OP 33 %
Stripped Water: 37 m³/hr; R/d Temp(°C): 48 pH: 27-Jun 5.3 H2S: 27-Jun 0.09 ppm NH3 27-Jun 16.8 ppm
Remarks: Unit steady.

UNIT 35: SRU (SOL 260 Tons/day) 255.6963814


Train 1: Feed(Acid Gas) ex U33: 3,197 Nm³/hr Temp(°C) Main Burner Claus#1 Claus#2 Claus#3 Super Claus Incinerator
Feed(Sour Gas) ex U34: 744 Nm³/hr Inlet Tag not found 951 232.0 205.0 192.0 225.0 670
Sulfur Production Rate: 109 T/day Bed Outlet 272 305.1 220.7 193.4 255.0 365
Furnace Press: 0.55 kg/cm² Reactors Delta T 73.1 15.7 1.5 30.0 Pit Lvl 54.2%
LLE status: ON

Train 2: Feed(Acid Gas) ex U33: 3,075 Nm³/hr Temp(°C) Main Burner Claus#1 Claus#2 Claus#3 Super Claus Incinerator
Feed(Sour Gas) ex U34: 0 Nm³/hr [-11059]
Inlet No Good Data For 692
Calculation 229.8 203.0 190.1 225.0 680
Sulfur Production Rate: 96 T/day Bed Outlet 305 311.0 222.3 194.1 252.8 371
Furnace Press: 0.28 kg/cm² Reactors Delta T 81.2 19.3 4.0 27.7 Pit Lvl 54.2%
LLE status: ON Incinerator O2 % QC009 10.02 QC209 Bad SO2 ex Common Stack: 1673 vol ppm
Remarks: 35UZA-215 unable to close causing no sour gas from U34 to SRU train 2. 35UZA-115 attended by shift instrument and able to close.

SIPS: Tr-2 35BZA 202/203, 35TZA 274/273.


UNIT 51/52/53/54/55/56/58/65: UTILITIES
Boiler Load (Tons/hr) Steam T (oC) pH (Analyzer/Lab) Cond.(Analyzer/lab) µS/cm Ex O2 % Remarks Natural Gas import:
2
F5101 MAN 0 - - - - - 12.7 Not Available NG Pressure : 44.44 kg/cm
F5102 MAN 0 -1 2.6 10.21 0.1 212.0 12.7 Not Available Total PSR-1: 12,968 Nm³/hr
F51201 MAN 52 399 9.9 10.84 703.5 485.0 3.3 Online Total PSR-2: 15,776 Nm³/hr
F51202 MAN 51 398 10.1 10.03 150.8 144.8 3.6 Online PSR-2 Fuel Gas: 12,904 Nm³/hr
F51203 MAN 0 33 10.2
[-11059]
10.02
No Good Data For Calculation
191.8 21.6 S/By PSR-2 HPU: 3,676 Nm³/hr
Total Load 103 LP Steam to Vent % 9 -5 N2 ex MOX plant: 2057 Nm³/hr Total = 45,325 Nm³/hr
Demin Anion Cond. Mix. Bed Cond. Flow (m³/hr) Demin. Tank Level: T5101 : 9.4 m PSR-1 FG Header PSR-2 FG Header
2
A5101A 0.07 0.07 63 T51203 : 11.6 m Press: 3.28 kg/cm Press: 3.30 kg/cm2
A5101B 0.24 0.16 71 Cond. Tank Level: T51201 : 9.6 m Dens.: 0.85 kg/Sm³ Dens.: 0.76 kg/Sm³
A51207 -0.06 0.08 145 T51202 : 4.9 m H2S (m): 50.0 ppm H2S (m): 5.0 ppm
Cooling Water Open Loop: Flow: 2,419 m³/hr pH 7.4 Fire Water Level: T5201 : 16.2 m [-11059]
H2SNo(QI):
Good Data For
ppmCalculation
H2S (QI): 50.1 ppm
Press.: 5.3 kg/cm2 Make-up: 27 m³/hr P5304: A, B T5202 : 16.4 m Air IA (1) 7.67 IA (2) 7.60
Cooling Water Closed Loop: Flow: 10,792 m³/hr pH 9.6 City Water Level: T5204 : 5.9 m System: PA (1) 7.77 PA (2) 7.78
Press.: 9.7 kg/cm2 P53201: C P53202: A & B T5205 : 6.1 m K5401A/B: B K54201A/B/C: A, C
Remarks: Cooling water line leak at unit 33. Inspection conduct UTTM for thicknes verification on other point.

Sea Water C/W plate exchg A still isolated, plan to change more plate. Seawater pump now on test run parallel running, 1 turbine and 1 motor for performance study.
SIPS: Faulty temp indication on NDE for P-51206A.
UNIT 59: COGEN
2
Natural Gas Import: 194 Nm³/hr Pressure 44.44 kg/cm MW MVAR PF GOV AVR ton/h degC kg/cm2 Cond. pH
Electricity Production: 72 MWh GTG1 15.0 n/a n/a n/a n/a HRSG1 51.7 408 44.0 108 8.9
Electricity Import: 0 MWh GTG2 14.0 n/a n/a n/a n/a HRSG2 51.6 408 44.6 132 9.9
Steam to Header: HP 188 ton/hr GTG3 12.0 n/a n/a n/a n/a HRSG3 51.4 408 44.5 89 9.8
Steam to STG: HP 25 ton/hr GTG4 16.0 n/a n/a n/a n/a HRSG4 51.6 408 44.1 103 9.6
MP 0 LP 27 ton/hr STG 15.0 n/a n/a n/a n/a
Remarks: Unit steady.

MG3: Steam blowing MP steam line from U29 piperack to U18/19 on/off.

UNIT 66/70's: S&D


ETS: T6601 Level(%): 41 T6603[-11059]
Level(%):
No Good Data ForT6605
Calculation
Level(%): 67
[-11059]
TOC:
No Good Data For Calculation ETS current status: discharge to sea in progress
Flow to ETS (m3/hr): Oily H2O: 0 Surface H2O: [-11059]ExNo
T 66202:
Good Data100
For Calculation
Total: ####### ####### Oily Surface Water pH: 8/6
Effluent water T - 6649: O & G: 4.5 mg/l S/S: 19 mg/l COD: 84 mg/l Phenol: 0.17 mg/l Ballast Water(mm): T-6619 T-6620 T-6621
T - 6647: O & G: 5.2 mg/l S/S: 29 mg/l COD: 90 mg/l Phenol: 0.16 mg/l 9336 9915 7457
SHIPMENT: Vessel Stock Volume(MB) Status Lift Station #8 69 % T7305 RVP tnk/line 67 67 kPa
Altius HSFO / LSFO 100 / 65 sailed TANK SERVICE: T7306 RVP tnk/line 70 66 kPa
MT TI Topaz Ratawi / IH / Banoco 550 / 750 / 500 hold Tank Service Lift Station Status

Remarks: VLCC discharge on hold till T-71204 ready. Now tank still feeding to unit. Expected by 1000hrs.

RV MONITORING REPORT (> SP)


Click to Update Curent Report Help 264
Start: 29-Jun-08 19:00 End: 30-Jun-08 07:00
AREA Count No. RV Involved Remarks
AREA 1 0 0
AREA 2 0 0
AREA 3 0 0
AREA 4 0 0
AREA 5 0 0

07/01/2008, 7:17 AM, Page 3 of 3