FuelGen 65 Spec Sheet 04-10
FuelGen 65 Spec Sheet 04-10
FuelGen 65 Spec Sheet 04-10
FuelGen®
Hydrogen Generation Systems
ELECTROLYTE
Proton Exchange Membrane (PEM) - caustic free
HYDROGEN PRODUCTION
Net Production Rate:
kg per 24 hours 21.6 kg/24 hr 43.3 kg/24 hr 65 kg/24 hr
Nm3/hr @ 0° C, 1 bar 10 Nm3/hr 20 Nm3/hr 30 Nm3/hr
SCF/hr @ 70° F, 1 atm 382 SCF/hr 764 SCF/hr 1146 SCF/hr
SLPM @ 70° F, 1 atm 178 SLPM 356 SLPM 535 SLPM
Delivery Pressure - Nominal 30 barg (435 psig)
Power consumed per unit Electrolyzer* 70.1 kWh/kg 69.0 kWh/kg 67.8 kWh/kg
mass H2 gas produced Thermal Control Unit* 6.0 kWh/kg 5.9 kWh/kg 5.8 kWh/kg
Purity (Concentration of Impurities) (99.9995%) water vapor < 5 ppm, -65°C (-85°F) dewpoint, N2 < 2 ppm
O2 < 1 ppm, all others undetectable
www.protonenergy.com | T 203.949.8697 | F 203.949.8016 | Proton Energy Systems 10 Technology Drive Wallingford, CT 06492 | customerservice@protonenergy.com
Model FuelGen 22 FuelGen 43 FuelGen 65
ELECTRICAL SPECIFICATIONS
Recommended breaker rating 100 kVA 200 kVA 250 kVA
Electrical specification 342 to 456 VAC, 3 phase, 50 Hz
432 to 528 VAC, 3 phase, 60 Hz
CONTROL SYSTEMS
Standard Features Fully automated, push button start/stop, E-stop, on-board H2 leak detection.
Automatic fault detection and system depressurization.
Remote Alarm Form C relay, 5A, 250V, 150W max. rated switching
Remote Shutdown Safety circuit trip
ENCLOSURE CHARACTERISTICS
Dimensions, W x D x H (Product) Fluids enclosure: 2362 mm x 914 mm x 1829 mm (93” x 36” x 72”)
Power supply enclosure: 1880 mm x 914 mm x 1829 mm (74” x 36” x 72”)
Weight (Product) 2041 kg (4500 lbs) 2449 kg (5400 lbs) 2812 kg (6200 lbs)
ADDITIONAL FEATURES
- On-board DI water system - Remote datalogging, dedicated computer - Factory matched cooler/chiller - Product oxygen @ 1.5 barg
- Dewpoint Meter - Outdoor operation package - Programmable time of day (98% purity overall; 99.5%
- Email notification excluding water)
Proton Energy Systems offers a wide range of options to tailor your HOGEN hydrogen generation system to meet your specific operational requirements.
Please contact your local representative to discuss the current list of options available to best fit your needs.
Preliminary; subject to change without notice. Proton Energy Systems reserves the right to make changes without further notice to this product.
Consult Proton Energy Systems Applications Department for proper installation guidelines.
PD-0600-0070 Rev. 3
©2009 - 2010 Proton Energy Systems, Inc. All Rights Reserved.
Proton, Proton Energy Systems, the Proton symbol, HOGEN, and FuelGen
ENERGY SYSTEMS
are registered trademarks of Proton Energy Systems, Inc.