POWER OPTIMIZER

SolarEdge Power Optimizer


Module Add-On for Commercial Installations
P600 / P700 / P800p / P800s

PV power optimization at the module-level


The most cost effective solution for commercial and large field installations
Specifically designed to work with SolarEdge inverters
Up to 25% more energy
Superior efficiency (99.5%)
Balance of System cost reduction; 50% less cables, fuses and combiner boxes,
over 2x longer string lengths possible
Fast installation with a single bolt
Advanced maintenance with module-level monitoring
Module-level voltage shutdown for installer and firefighter safety
Use with two PV modules connected in series or in parallel

USA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA- www.solaredge.com


HUNGARY-SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC
SolarEdge Power Optimizer Module Add-On For
Commercial Installations P600 / P700 / P800p / P800s
Optimizer model P600 P700 P800p P800s
(typical module compatibility) (for 2 x 60-cell (for 2 x 72-cell (for parallel connection of (for series connection of
PV modules) PV modules) 2x 96-cell 5’’ PV modules) 2x high power or bi-facial
modules)
INPUT
Rated Input DC Power(1) 600 730 800 W
Absolute Maximum Input Voltage
96 125 83 120 Vdc
(Voc at lowest temperature)
MPPT Operating Range 12.5 - 80 12.5 - 105 12.5 - 83 12.5 - 105 Vdc
Maximum Short Circuit Current (Isc) 10.25 14 12.5 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.6 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15 18 Adc
Maximum Output Voltage 85 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety)
RoHS Yes 
Fire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Three phase inverters Three phase inverters
Compatible SolarEdge Inverters
SE15K & larger SE16K & larger
Maximum Allowed System Voltage 1000 Vdc
128 x 152 x 43 / 128 x 152 x 50 / 128 x 158 x 59 / 128 x 152 x 59 /
Dimensions (W x L x H) mm / in
5 x 5.97 x 1.69 5 x 5.97 x 1.93 5 x 6.22 x 2.32 5 x 5.97 x 2.32
Weight (including cables) 834 / 1.8 933 / 2.1 1019 / 2.2 1064/2.3 gr / lb
Input Connector(2) MC4 MC4 Dual Input(6) MC4
Output Connector MC4
1.2 / 3.9 (portrait 1.2 / 3.9 (portrait 1.2 / 3.9 (portrait 1.2 / 3.9 (portrait
orientation) or orientation) or orientation) or orientation) or
Output Wire Length m / ft
1.8 / 5.9 (landscape 2.1 / 6.9 (landscape 1.8 / 5.9 (landscape 2.1 / 6.9 (landscape
orientation) orientation) orientation) orientation)
Operating Temperature Range(3) -40 - +85 / -40 - +185 ˚C / ˚F
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(1)
Rated STC power of the module. Module of up to +5% power tolerance allowed.
(2)
For other connector types please contact SolarEdge.
(3)
For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Application Note for more details.

PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE SE15K THREE PHASE SE16K THREE PHASE
INVERTER(5)(6) AND LARGER AND LARGER FOR MV GRID
Compatible Power Optimizers P600 P600, P700 P800 P600, P700 P800
Power Optimizers 13 12 13
Minimum String Length
PV Modules 26 24 26
Power Optimizers 30
Maximum String Length
PV Modules 60
Maximum Power per String 11250(7) 13500 12750(8) 15300 W
Parallel Strings of Different Lengths or Orientations Yes  
(5)
P600 and P700 can be mixed in one string. It is not allowed to mix P600/P700/P800 with P300/P370/P500/P404/P405/P505 in one string.
(6)
In a case of odd number of PV modules in one string it is allowed to install one P600/P700/P800 power optimizer connected to one PV module. When connecting a single module to the P800p seal the unused
input connectors with the supplied pair of seals.
(7)
For SE27.6K, SE50K, SE55K, SE82.8K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to
2,000W; inverter max DC power: 37,250W.
(8)
For inverters for MV grid: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter
max DC power: 45,000W.

© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 12/2017/V01/ENG ROW. Subject to change without notice.