Speed Flex
Speed Flex
Speed Flex
Section I Issue 2
Alternatives: Construction:
Standard RG 142 B/U: Conductor Solid silver plated copper 0,94
30000-142-00 Dielectric Low-foamed PE 2,95
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
95 pF/m
MHz
100
dB/100m
15
6
Velocity of signal propagation 70 % 200 21
Signal delay 4.7 ns/m 400 32
Working voltage, AC r.m.s. 1600 max 900 51
Working voltage, DC
Attenuation, typical values
3200 max
see table
1200
1500
61
69
7
(nominal values at an air temperature of +20°C) 1800 78
Power, typical values see table 2000 83
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 95
Suitable for frequencies
Shielding effectiveness
up to 3 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 25mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 50mm
passes IEC 60332-1
100
200
269
189
9
Flammability passes UL 1581 VW-1 400 133
Halogen free passes IEC 60754-2 900 90
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
73
65
60
10
2000 55
2500 50
11
12
Ref: SX-eSX142-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Standard RG 179 B/U: Conductor Silver plated copper covered steel (7x0,10) 0,30
30000-179-00 Dielectric Low-foamed PE 1,60
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
75 ± 3 Ohms
64 pF/m
MHz
100
dB/100m
24
6
Velocity of signal propagation 70 % 200 34
Signal delay 4.7 ns/m 400 48
Working voltage, AC r.m.s. 900 max 900 72
Working voltage, DC
Attenuation, typical values
1800 max
see table
1200
1500
83
93
7
(nominal values at an air temperature of +20°C) 1800 105
Power, typical values see table 2000 112
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 127
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 8mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 30mm
passes IEC 60332-1
100
200
73
52
9
Flammability passes UL 1581 VW-1 400 37
Halogen free passes IEC 60754-2 900 25
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
22
20
16
10
2000 15
2500 13
11
12
Ref: SX-eSX179-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Speedflex 295 UL 1375: Conductor Solid silver plated copper 1,12
34000-295-01 Dielectric High-foamed PE 2,95
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
82 pF/m
MHz
100
dB/100m
11
6
Velocity of signal propagation 82 % 200 16
Signal delay 4 ns/m 400 23
Working voltage, AC r.m.s. 400 max 900 36
Working voltage, DC
Attenuation, typical values
800 max
see table
1200
1500
42
48
7
(nominal values at an air temperature of +20°C) 1800 53
Power, typical values see table 2000 57
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 65
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 25mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 75mm
passes IEC 60332-1
100
200
282
194
9
Flammability passes UL 1581 VW-1 400 133
Halogen free passes IEC 60754-2 900 85
Smoke generation
Connectors
passes IEC 61034-2
please ask for details
1200
1500
1800
73
65
60
10
2000 55
2500 50
11
12
Ref: SX-eSX295-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Standard RG 316 /U: Conductor Silver plated copper (7x0,17) 0,54
30000-316-00 Dielectric Low-foamed PE 1,52
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
95 pF/m
MHz
100
dB/100m
26
6
Velocity of signal propagation 70 % 200 38
Signal delay 4.7 ns/m 400 53
Working voltage, AC r.m.s. 1000 max 900 83
Working voltage, DC
Attenuation, typical values
2000 max
see table
1200
1500
100
113
7
(nominal values at an air temperature of +20°C) 1800 126
Power, typical values see table 2000 135
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 152
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 9mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 30mm
passes IEC 60332-1
100
200
86
58
9
Flammability passes UL 1581 VW-1 400 42
Halogen free passes IEC 60754-2 900 30
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
23
21
19
10
2000 18
2500 15
11
12
Ref: SX-eSX316-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Standard RGD 316 : Conductor Silver plated copper (7x0,17) 0,54
30000-316-05 Dielectric Low-foamed PE 1,52
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
94 pF/m
MHz
100
dB/100m
26
6
Velocity of signal propagation 70 % 200 38
Signal delay 4.7 ns/m 400 53
Working voltage, AC r.m.s. 1000 max 900 83
Working voltage, DC
Attenuation, typical values
2000 max
see table
1200
1500
100
113
7
(nominal values at an air temperature of +20°C) 1800 126
Power, typical values see table 2000 135
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 152
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 9mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 30mm
passes IEC 60332-1
100
200
86
58
9
Flammability passes UL 1581 VW-1 400 42
Halogen free passes IEC 60754-2 900 30
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
23
21
19
10
2000 18
2500 15
11
12
Ref: SX-eSX316d-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Speedflex 375 UL 1375: Conductor Solid silver plated copper 1,40
34000-375-01 Dielectric High-foamed PE 3,75
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
82 pF/m
MHz
100
dB/100m
9
6
Velocity of signal propagation 82 % 200 13
Signal delay 4 ns/m 400 18
Working voltage, AC r.m.s. 500 max 900 29
Working voltage, DC
Attenuation, typical values
1000 max
see table
1200
1500
34
38.5
7
(nominal values at an air temperature of +20°C) 1800 42.5
Power, typical values see table 2000 46
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 52
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 29mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 85mm
passes IEC 60332-1
100
200
374
262
9
Flammability passes UL 1581 VW-1 400 175
Halogen free passes IEC 60754-2 900 110
Smoke generation
Connectors
passes IEC 61034-2
please ask for details
1200
1500
1800
95
85
75
10
2000 70
2500 60
11
12
Ref: SX-eSX375-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Standard RG 393 /U: Conductor Silver plated copper (7x0,80) 2,43
30000-393-00 Dielectric Low-foamed PE 7,24
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
95 pF/m
MHz
100
dB/100m
8
6
Velocity of signal propagation 70 % 200 12
Signal delay 4.7 ns/m 400 16
Working voltage, AC r.m.s. 4400 max 900 26
Working voltage, DC
Attenuation, typical values
8800 max
see table
1200
1500
30
34
7
(nominal values at an air temperature of +20°C) 1800 38
Power, typical values see table 2000 41
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 50
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 50mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 180m
passes IEC 60332-1
100
200
857
598
9
Flammability passes UL 1581 VW-1 400 414
Halogen free passes IEC 60754-2 900 265
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
224
200
180
10
2000 170
2500 150
11
12
Ref: SX-eSX393-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Standard RG 400 /U: Conductor Silver plated copper (19x0,20) 0,98
30000-400-00 Dielectric Low-foamed PE 2,95
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
95 pF/m
MHz
100
dB/100m
16
6
Velocity of signal propagation 70 % 200 23
Signal delay 4.7 ns/m 400 33
Working voltage, AC r.m.s. 1500 max 900 53
Working voltage, DC
Attenuation, typical values
3000 max
see table
1200
1500
63
71
7
(nominal values at an air temperature of +20°C) 1800 79
Power, typical values see table 2000 84
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 96
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 25mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 50mm
passes IEC 60332-1
100
200
245
173
9
Flammability passes UL 1581 VW-1 400 122
Halogen free passes IEC 60754-2 900 80
Smoke generation
Connectors
passes IEC 61034-2
compatible with all standard types
1200
1500
1800
67
60
55
10
2000 50
2500 45
11
12
Ref: SX-eSX400-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Speedflex 585 UL 1375: Conductor Solid silver plated copper 2,22
34000-585-01 Dielectric High-foamed PE 5,85
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
82 pF/m
MHz
100
dB/100m
7
6
Velocity of signal propagation 82 % 200 9
Signal delay 4 ns/m 400 14
Working voltage, AC r.m.s. 750 max 900 21
Working voltage, DC
Attenuation, typical values
1500 max
see table
1200
1500
25
29
7
(nominal values at an air temperature of +20°C) 1800 33
Power, typical values see table 2000 36
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 42
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
-60 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 45mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 135mm
passes IEC 60332-1
100
200
698
477
9
Flammability passes UL 1581 VW-1 400 318
Halogen free passes IEC 60754-2 900 195
Smoke generation
Connectors
passes IEC 61034-2
please ask for details
1200
1500
1800
157
140
125
10
2000 115
2500 100
11
12
Ref: SX-eSX585-03
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2008-03-20
publication and is subject to change without prior notice. Approved by: