Tp03ac 2018
Tp03ac 2018
Tp03ac 2018
The rated output power of TP03AC series is 3W with wide input voltage range, for both AC input
and DC input application. High reliability, precision, large power density, ultra-small size, no
external heat sink required, stable output voltage and etc, with over current protection, EMI filter
circuit, the rectifier filter circuit, 3000V isolation voltage, short circuit, overload, internal thermal
protection, Widely used in telecommunications, industrial control, instrument, data acquisition,
signal control and other electronic systems.
FEATURES
Universal input voltage range Both for AC and DC input voltage Wide input voltage:2:1 and 4:1
Fixed switching frequency Overheat protection Over current protection
Short circuit protection RoHS compliant Operating temperature :-40ºC to 70ºC
SELECTION GUIDE
Input Voltage Output Efficiency Recommend output external
Part Number Rated Range values Current (Typ. )
Voltage(VDC) C1、C2、C3 C4
(VAC) (A) %
TP03AC220S05 220(2:1) 165-265 5 0.6 71 0.1uF/25V 330uF/16V
TP03AC220S12 220(2:1) 165-265 12 0.25 76 0.1uF/25V 220uF/25V
TP03AC220S15 220(2:1) 165-265 15 0.20 77 0.1uF/25V 220uF/25V
TP03AC220S24 220(2:1) 165-265 24 0.12 77 0.1uF/25V 100uF/35V
TP03AC220D05 220(2:1) 165-265 ±5 ±0.3 71 0.1uF/25V 220uF/16V
TP03AC220D12 220(2:1) 165-265 ±12 ±0.125 76 0.1uF/25V 100uF/25V
TP03AC220D15 220(2:1) 165-265 ±15 ±0.1 78 0.1uF/25V 100uF/25V
TP03AC220S03W 220(4:1) 85-265 3.3 0.6 71 0.1uF/25V 330uF/16V
TP03AC220S05W 220(4:1) 85-265 5 0.6 71 0.1uF/25V 330uF/16V
TP03AC220S06W 220(4:1) 85-265 6 0.5 71 0.1uF/25V 330uF/16V
TP03AC220S09W 220(4:1) 85-265 9 0.33 71 0.1uF/25V 330uF/16V
TP03AC220S12W 220(4:1) 85-265 12 0.25 76 0.1uF/25V 220uF/25V
TP03AC220S15W 220(4:1) 85-265 15 0.20 77 0.1uF/25V 220uF/25V
TP03AC220S24W 220(4:1) 85-265 24 0.12 77 0.1uF/25V 100uF/35V
TP03AC220D05W 220(4:1) 85-265 ±5 ±0.3 71 0.1uF/25V 220uF/16V
TP03AC220D12W 220(4:1) 85-265 ±12 ±0.125 76 0.1uF/25V 100uF/25V
TP03AC220D15W 220(4:1) 85-265 ±15 ±0.1 78 0.1uF/25V 100uF/25V
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation voltage Input / Output 1 minute, leakage current 2mA 3000 VAC
Seismic 10~55Hz 5 5 G
Over current protection Full input range Auto recovery
Cooling Free air convection
Case material Flame-retardant plastic
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Startup voltage 220VAC In module(165V-265V) 165 220 265 VAC
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
±3 %
Voltage accuracy Io=0.1D1.0 x Ionom Vi=Vi rated
±5 %
Line regulation Vimin≤Vi≤Vimax ±0.5 %
ENVIRONMENT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Operating temperature industrial-class -40 +70 ℃
MECHANICAL DIMENSIONS
37.00
0.80
2 3
5
1
33.00
MODEL SELECTION
TP 03 A C 220 D 05 W TP 03 A C 220 T 05 D 12 W
W:4:1 Wide voltage input range
W:4:1 Wide voltage input range Auxiliary Output Voltage
Brand name
RECOMMEND CIRCUIT
S in gle O utput
FG D ua l O utpu t(C OM )
+V 0 FG
+V 0
N + +
F U SE + + N FUS E C1 C3 CO M
A C -DC
C1 C2 AC-DC
+ C4 +
L -V0 L C1
-V 0
C1, C2, C3, C4, C5, C6 capacitor values refer to parameter table
USING ATTENTIONS
Module will cause irreversible damage when it in the long-term overload state.
Module will cause irreversible damage when it out of the state maximum input voltage range