IK PI - 2015 Industrial Communication SIMATIC NET PDF
IK PI - 2015 Industrial Communication SIMATIC NET PDF
IK PI - 2015 Industrial Communication SIMATIC NET PDF
Industrial
Communication
SIMATIC NET
Catalog Edition
IK PI 2015
Related catalogs
SIMATIC ST 70 Motion Control PM 21
Products for SIMOTION, SINAMICS S120 & SIMOTICS
Totally Integrated Automation Equipment for Production Machines
E86060-K4670-A101-B4-7600 E86060-K4921-A101-A3-7600
E86060-K4670-A151-A7-7600 E86060-K4461-A101-A3-7600
E86060-K4678-A111-B9-7600 E86060-K5581-A111-A6-7600
E86060-K8310-A101-A9-7600 E86060-K6850-A101-C4
E86060-K1010-A101-A4-7600 E86060-D4001-A510-D4-7600
Industry Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
© Siemens AG 2014
Industrial Communication
SIMATIC NET
Introduction
1
PROFIBUS
3
AS-Interface
4
Catalog IK PI · 2015
Supersedes: IO-Link
5
Catalog IK PI · 2012
Industrial Security
8
Appendix
9
www.pefc.org
2 Siemens IK PI · 2015
© Siemens AG 2014
The Siemens Industry Sector is the We consistently rely on integrated tech- Market launch times can be reduced
world's leading supplier of innovative nologies and, thanks to our bundled by up to 50% due to the combination
and environmentally friendly products portfolio, we can respond more quickly of powerful automation technology
and solutions for industrial companies. and flexibly to our customers' wishes. and industrial software from Siemens
End-to-end automation technology and With our globally unmatched range of Industry. At the same time, the costs for
industrial software, solid market exper- automation technology, industrial energy or waste water for a manufac-
tise, and technology-based services are control and drive technology as well turing company can be reduced signifi-
the levers we use to increase our cus- as industrial software, we equip compa- cantly. In this way, we increase our
tomers’ productivity, efficiency and nies with exactly what they need over customers’ competitive strength and
flexibility. With a global workforce of their entire value chain – from product make an important contribution to envi-
more than 100 000 employees, design and development to production, ronmental protection with our energy-
the Industry Sector comprises the sales and service. Our industrial custom- efficient products and solutions.
Industry Automation, Drive Technolo- ers benefit from our comprehensive
gies, and Customer Services divisions, portfolio, which is tailored to their
as well as the Metals Technologies market and their needs.
Business Unit.
Siemens IK PI · 2015 3
© Siemens AG 2014
(53 ²(QWHUSULVH5HVRXUFH3ODQQLQJ
(WKHUQHW
,QGXVWULDO(WKHUQHW
7,$3RUWDO
&RQWURO/HYHO
6,0$7,&3&6
6,180(5,. 6,027,21 6,0$7,&1(7 6,0$7,&&RQWUROOHU
6,0$7,&+0, 6,5,86,QGXVWULDO&RQWUROV
$XWRPDWLRQ
&RPSXWHU1XPHULF&RQWURO 0RWLRQ&RQWURO ,QGXVWULDO
0RGXODU3&%DVHG +XPDQ0DFKLQH,QWHUIDFH
6\VWHP
&RPPXQLFDWLRQ
)LHOG/HYHO
352),%863$
3URFHVV,QVWUXPHQWDWLRQ 6,0$7,&,GHQW 6,0$7,&'LVWULEXWHG,2 6,1$0,&6'ULYH6\VWHPV 6,7236WURPYHUVRUJXQJ
,QGXVWULDO,GHQWLILFDWLRQ
Efficient engineering is the first step toward better production that is faster,
more flexible, and more intelligent. With all components interacting efficiently,
Totally Integrated Automation (TIA) delivers enormous time savings right from
the engineering phase. The result is lower costs, faster time-to-market, and
greater flexibility.
4 Siemens IK PI · 2015
© Siemens AG 2014
• Integrated engineering
Consistent, comprehensive engineering throughout the
entire product development and production process
• Industrial data management
Access to all important data occurring in productive
operation – along the entire value chain and across
all levels
352),1(7 • Industrial communication
,QGXVWULDO(WKHUQHW
Integrated communication based on international
352),%86
cross-vendor standards that are mutually compatible
$6,QWHUIDFH
• Industrial security
.1;*$00$LQVWDEXV
Systematic minimization of the risk of an internal or
7RWDOO\ external attack on plants and networks
,QWHJUDWHG
3RZHU • Safety Integrated
Reliable protection of personnel, machinery, and the
environment thanks to seamless integration of safety
technologies into the standard automation
Siemens IK PI · 2015 5
© Siemens AG 2014
Smart interfaces allow linking to industrial or building automation, making it possible to fully
exploit all the optimization potential of an integrated solution. This is how we provide our
customers around the world with answers to their challenges. With highly efficient, reliable,
and safe power distribution, we lay the foundation for sustainable infrastructure and cities,
Comprehensive answers for
power distribution in complex buildings, and industrial plants. We bring power to the point – wherever and whenever it is
energy systems – from Siemens needed.
6 Siemens IK PI · 2015
© Siemens AG 2014
Electrification
Renewables
≤ 110 kV
Siemens IK PI · 2015 7
© Siemens AG 2014
8 Siemens IK PI · 2015
1
© Siemens AG 2014
Introduction
Siemens IK PI · 2015
© Siemens AG 2014
Introduction
Industrial communication
1
SIMATIC NET offers all the components necessary for an
integrated complete solution and supports the following bus
systems:
Industrial Ethernet - the industrial standard based on the PROFIBUS - the international standard for the field level is
(IEEE 802.3) international Ethernet standard (IEC 61158/61784) the global market leader among fieldbus
systems
PROFINET - the leading Industrial Ethernet standard
(IEC 61158/61784) for automation
Introduction
Industrial communication
AS-Interface IO-Link
AS-Interface - the international standard, which, as an IO-Link - the standard for intelligently connecting
(IEC 62026-2/EN 50295) economical alternative to the cable sensors and actuators from the field level
harness, links sensors and actuators to the MES level
by means of a two-wire line.
Introduction
Industrial communication
1 ■ Overview ■ Benefits
Your requirements Industrial communication with Totally Integrated Automation
Do you want to bring new products quickly onto the market? And With Totally Integrated Automation, Siemens is the only manufac-
at the same time be flexible and in a position to change your turer to offer an integrated range of products and systems for au-
product range at short notice and shorten your time-to market? tomation in all sectors – from incoming goods and the production
Do you want to be able to manufacture efficiently at low costs? process to outgoing goods, from the field level through the pro-
And at the same time optimize the capacity of your plant/ duction control level to connection with the corporate manage-
machine and minimize possible downtimes? ment level.
Then all the machines in your plant should work together per- The advantages of Totally Integrated Automation already pay off as
fectly. Therefore, you rely upon open, integrated automation regards design and engineering, but also assembly and commis-
communication not just within the whole company but also for sioning and operation and maintenance.
external communication. Avoid isolated automation and informa-
tion technology solutions by assuring: Automation solutions can be implemented at little cost. New scope
• Continuous flow of information from the actuator/sensor for development allows a quicker and more flexible response to
level through to the corporate management level new market requirements. Systems can be easily expanded or con-
• Availability of information at any location verted without having to interrupt ongoing operations. Due to the in-
creased use of Industrial Ethernet in automation, two topics within
• High-speed data exchange between the different plant Totally Integrated Automation are becoming more and more impor-
sections
tant – PROFINET and SCALANCE.
• Easy, plant-wide configuration and efficient diagnostics
• Integrated security functions that block unauthorized access
• Fail-safe and standard communication via the same
connection
Our range
Worldwide trends
Introduction
Industrial communication
■ Benefits (continued)
1
PROFINET ... Use of communication systems
for increasing the productivity of your plant
Industrial Ethernet
You need a seamless information flow for your strategic decisions
PROFIBUS DP
within your company – from the first manufacturing step through op-
AS-Inteface
PROFINET
eration up to the corporate management level. In order to achieve
this, you rely on efficiency and transparency already during engi-
IO-Link
neering.
PROFINET, the open and innovative Industrial Ethernet standard
fulfils all the demands of industrial automation and ensures inte-
grated, company-wide communication. Enterprise Resource Planning (ERP)
● ○
(e.g. PC)
PROFINET also supports the direct connection of distributed field
devices to Industrial Ethernet and the implementation of isochro-
nous motion control applications. PROFINET also allows distributed Control
● ● ● ○
(e.g. SIMATIC S7-300)
automation with the support of component technology, as well as
vertical integration and the implementation of safety-oriented appli-
cations. PROFINET also supports controller-controller communica- Motion Control
● ● ●
tion. (e.g. SIMOTION)
Securely and flexibly networked across all levels with Intelligent field devices
SCALANCE network components ● ● ● ●
(e.g. ET 200S/CPU)
SCALANCE X Industrial Ethernet Switches, SCALANCE S
Industrial Security Modules and Industrial Wireless LAN (IWLAN) Simple field devices
● ● ● ●
access points, client modules (SCALANCE W) and SCALANCE M (e.g. ET 200)
industrial routers that ideally meet the demands of industrial appli-
cations are available for networking the stations on the
PROFINET/Industrial Ethernet. Sensors/actuators ● ● ● ●
G_IK10_XX_00003
requiring cables and remain flexible in the choice of route.
An overall solution comprises:
Safety-oriented Communication ● ● ●
• Bus system with
- Passive network components, e.g. cables
- Active network components, e.g. switches not suitable ○ suitable ● ideally suitable
Introduction
Industrial bus systems
1
Industrial bus systems Laptop
Remote access,
e.g. via
teleservice
PROFINET
Industrial Ethernet
Controller
Notebook
Coupler
PROFIBUS PA PROFIBUS
ASM456
Field devices
SIMOCODE Mobile
pro Panel
RFID Code
system reading
systems
IO-Link
module
SINAMICS
Compact Protection and RFID system Drives
starter monitoring
devices
G_IK10_XX_00006
Introduction
Industrial bus systems
1
Telecontrol and
PC substation control
S7-1200 with
CP 1242-7
Controller
PC/PG/IPC
Database
Server
IWLAN
Controller Security
Access Access
Point Point
Controller PC/PG IWLAN Industrial Ethernet
RCoax Cable Switches
Controller
Wireless
Devices
Link
RF180C
Field devices Code
Mobile reading
Panel systems
Drives
IO-Link RFID
master Access
system Point
DP-Slave Motion Control
Systems
Link
IO-Link Link
Power module
Power
supply supply
Protection and
LOGO! Controller monitoring Client
devices Module
RFID system Compact
starter
AS-Interface
Compact Compact
starter feeder
G_IK10_XX_00007
Field device
Slaves Slaves
Signalling column
Introduction
Industrial bus systems
Industrial Ethernet
1 ■ Overview
Industrial Ethernet provides the industrial area with a powerful Ethernet is the world's current Number 1 in the network environ-
network that complies with the IEEE 802.3 (Ethernet) and ment and offers significant benefits:
802.11 a/b/g/h/n (wireless LAN) standards. • Fast commissioning thanks to the simplest connection method
The diverse options of Ethernet and the Internet that are already • High availability since existing networks can be extended
available today in the office sector can also be used in factory without any adverse effects
and process automation by means of Industrial Ethernet. • Virtually unlimited communication capabilities, since scalable
Ethernet technology, which has been used successfully for performance using switching technology and high data rates
decades, allows users to precisely match network performance are available
to requirements. The user can choose the data throughput rate
to suit particular needs, as integrated compatibility makes it pos- • Networking of the most varied application areas such as the
sible to introduce this technology in stages. office and production areas
• Company-wide communication thanks to the Internet
connection option, with security components providing for
data integrity
• Investment protection through continuous compatible further
development
• Precise time-based assignment of events in the overall plant
by means of plant-wide clock control.
SIMATIC NET, the industrial communication system from
Siemens, relies on this proven technology. Siemens has already
supplied several million connections worldwide in tough indus-
trial environments subject to electromagnetic interference.
SIMATIC NET provides important supplements to Ethernet
technology for industrial environments:
• Network components of the SCALANCE product families for
the use of wired and wireless communication in harsh indus-
trial environments
• Fast on-site assembly using the FastConnect cabling system
• Failsafe networks through high-speed redundancy and
redundant power supply
• Continuous monitoring of network components through an
effective signaling concept, and network monitoring software
The following communication functions/services are offered by
Industrial Ethernet:
PG/OP communication
Comprises integrated communication functions which allow
data communication via SIMATIC, SIMOTION and SINUMERIK
automation systems with every HMI device and SIMATIC PG
(STEP 7). PG/OP communication is supported by PROFINET/
Industrial Ethernet and PROFIBUS.
S7 communication
S7 communication is the integrated communication function
(system function block) for S7-400 or loadable function blocks
for S7-300, which have been optimized within SIMOTION,
SINUMERIK and SIMATIC S7/WinAC. It also enables PCs/IPCs
and workstations to be connected. The maximum volume of user
data per task is 64 KB. S7 communication offers simple, power-
ful communication services and provides a network-indepen-
dent software interface.
Open communication
The open communication (SEND/RECEIVE) allows the SIMATIC S7
controllers to communicate with other SIMATIC S7 and SIMATIC S5
controllers, PCs/IPCs and third-party systems. In addition, for the
simple connection of HMI stations, FETCH and WRITE are offered.
Introduction
Industrial bus systems
Industrial Ethernet
■ Overview (continued)
1
PC with
WinCC flexible
and TeleControl
S7-400 Server Basic
Mobile
Panels
S7-1500 SINUMERIK
SIMOTION C/P/D
SIMATIC IPC
with WinAC
SCALANCE S
S7-300
Access Point
PROFINET SCALANCE W S7-1200
Industrial RF180C
Ethernet
SCALANCE X
Energy
monito- Code
ring reading
systems
Access Point ET 200S with
RFID
SCALANCE W IM 151-3 PN FO
system
Industrial Ethernet (optic)
ET 200
Client Module ET 200S with
SCALANCE W IM 151-3 PN FO
SINAMICS
G_IK10_XX_10230
SIMATIC IPC
with WinAC
ET 200
SIRIUS M200D
Introduction
Industrial bus systems
PROFINET
1 ■ Overview
PROFINET – The Ethernet standard for automation PROFINET innovations
PROFINET is the leading Industrial Ethernet standard with more PROFINET has been expanded by a number of innovative fea-
than 7,6 1) million nodes worldwide. tures. These simplify the system configuration, in safety-critical
applications for example, and support a leaner and more flexible
PROFINET makes businesses more successful by speeding up
topology in many different scenarios.
processes, boosting productivity, and increasing plant availability.
The I-Device (intelligent IO device) function enables simple
With PROFINET, Siemens is applying the Ethernet standard to
and fast controller-controller communication through direct ac-
automation. PROFINET enables high-speed and secure data
cess to the IO address image with the PROFINET IO protocol.
exchange at all levels, thus making it possible to implement in-
Local controllers such as the ET 200S CPU can be integrated
novative machine and plant concepts. Thanks to its flexibility
into modular machines more easily, for example.
and openness, PROFINET offers users maximum freedom when
engineering and structuring their plant architectures. The Shared Device function allows two controllers to access the
same PROFINET IO Device, such as a distributed ET 200 or a
PROFINET's efficiency means optimal utilization of available
drive in a safety application. Because fewer devices need to be
user resources and a significant increase in plant availability.
installed in the field, the engineering, cabling, energy and instal-
Innovative Siemens products and the performance of PROFINET
lation costs are reduced.
provide a sustained boost to company productivity.
Plant availability can be increased using a ring topology and the
Media Redundancy Protocol (MRP) This runs directly via the
integrated RJ45 ports on PROFINET devices and can be com-
bined in any way with the relevant Industrial Ethernet switches
(e.g. SCALANCE X-200).
High network availability can be achieved without reconfigura-
tion time using the MRPD procedure (Media Redundancy for
Planned Duplication).
Advantages at a glance
1)
Source: PROFIBUS and PROFINET International (PI), values at end of 2013
Introduction
Industrial bus systems
PROFINET
■ Overview (continued)
1
G_IK10_XX_10304
Web tools Fast device replacement Redundancy
Introduction
Industrial bus systems
PROFIBUS
1
Complete overview of PROFIBUS
SIMATIC S7
SINUMERIK
SIMOTION C/P/D
Notebook
S7-300F with standard
and F I/Os
Field PG M
PROFIBUS DP PROFIsafe
ET 200pro
ET
200M
DP/AS-i
MSS ET 200L ET 200M with LINK
MICRO- F-IO Advanced
SIMOCODE
MASTER Field devices
PRO
ASM456 ET AS-Interface
200eco
DP/AS- DP/AS-i
IO-Link Interface F-Link
Compact
module Link 20E
SINAMICS feeder
G_IK10_XX_50026
arrangement
RFID Code
system reading
systems
RFID Sensors IO modules
system
PROFIBUS is used to connect field devices, e.g. distributed I/O Openness all along the line
devices or drives, to automation systems such as SIMATIC S7,
SIMOTION, SINUMERIK or PCs. PROFIBUS is standardized in Dank Thanks to the openness of PROFIBUS DP, standard-
accordance with IEC 61158/61784 and is a powerful, open and compliant components from different manufacturers can also be
rugged fieldbus system with short response times. PROFIBUS is connected. The IEC 61158/61784 standards provide future pro-
available in different forms for various applications tection for your investment. A simple link to other bus systems,
e.g. from the AS-Interface, is implemented by means of links and
PROFIBUS DP thus permits an integrated solution in the field of failsafety for the
(distributed I/O) protection of both human and machine.
connecting distributed field devices, e.g. SIMATIC ET 200, or Siemens has a complete range of products of standard and fail-
drives with extremely fast response times. PROFIBUS DP is used safe controllers, network components, communication software
when sensors/actuators are distributed at the machine or in the and field devices. And for field device manufacturers, Siemens
plant (e.g. field level). The actuators and sensors are connected offers everything to do with the PROFIBUS DP interface, such as
to the field devices. ASICs, training, certification, and much more.
The field devices are supplied with output data in accordance
with the master/slave technique and transfer input data to the PROFIsafe
controller or PC. permits standard and safety-related communication on one and
the same bus cable. It is an open solution for safety-related com-
munication over standard buses and uses the PROFIBUS ser-
vices.
Introduction
Industrial bus systems
PROFIBUS
1
SIMATIC TDC
SIPART PS2
SIMATIC
PDM
*
PROFIBUS DP PROFIBUS PA
SITRANS P
G_IK10_XX_50027
Booster
Intrinsically safe area
The CPU, I/O and user program are synchronized with the expands PROFIBUS DP with intrinsically safe transmission of
PROFIBUS cycle. The "Isochronous mode" function is supported data and power (e.g. transducers in the food processing indus-
by many CPUs of SIMATIC, SIMOTION, SINUMERIK and servo try) in accordance with the international standard IEC 61158-2
drives. The drives are controlled using the PROFIdrive profile. (same protocol, different physical properties).
PROFIBUS PA is used predominantly in the hazardous areas of
refineries (chemical, oil and gas).
Introduction
Industrial bus systems
AS-Interface
1 ■ Overview
Sensors, valves, actuators, drives – many different components
operate on the field level. All of these actuators/sensors must be
connected to an automation system. Distributed I/O devices are
used for this; to a certain extent as intelligent outposts directly
on-site.
As a cost-effective alternative to the cable harness, AS-Interface
links the components of the field level by means of a simple 2-wire
cable for data and power.
AS-Interface is standardized as an international industrial standard
according to EN 50295 and IEC 62026-2 and is supported world-
wide by a number of member companies of the AS-International
Association, including the leading manufacturers of actuators and
sensors. AS-Interface is used where individual actuators/sensors
are spatially distributed throughout the machine (e.g. in a bottle fill-
ing plant).
AS-Interface is a single master system. There are communications
processors (CPs) for SIMATIC and for SIMOTION and links that con-
trol field communication as masters. With the AS-Interface specifica-
tion V2.1 or V3.0, up to 62 slaves can be connected. The AS-Inter-
face specification V3.0 allows a maximum of 1000 digital
inputs/outputs to be connected (profile S-7.A.A: 8DI/8DO as
A/B slave). New profiles allow extended addressing (A/B) to be used
for analog slaves, too. The analog value transmission is accelerated
via "fast analog profiles". Thanks to the integrated analog value pro-
cessing in the masters, the access to analog values is just as easy
as the access to digital values. For connecting the AS-Interface to
PROFIBUS DP, the DP/AS-i LINK Advanced, DP/AS-i F-Link or
DP/AS-Interface LINK 20E are available with degree of protection
IP20. This enables the use of AS-Interface as a subordinate network
for PROFIBUS DP. The IE/AS-i LINK PN IO allows AS-Interface to be
connected to Industrial Ethernet and thereby a direct embedding in
the PROFINET environment.
Introduction
Industrial bus systems
AS-Interface
■ Overview (continued)
1
SIMATIC/
SIMOTION SINUMERIK
PROFINET
Industrial Ethernet
DP/AS-i F-Link PROFIBUS DP
CM AS-i Master ST
DP/AS-i LINK Advanced for ET 200SP
S7-300
AS-Interface CP 343-2(P) DP/AS-i Link 20E S7-300
power supply CP343-2(P)
S7-200 AS-Interface
S7-1200
with CP 243-2 power supply
with CM 1243-2
IE/AS-i LINK PN IO
AS-Interface
Digital and analog Safety switch Safe Signaling Pushbuttons Safe and standard control cabinet
K20, K45, K60 field modules without with EMERGENCY-STOP columns Indicator lights modules S22.5 and S45
tumbler tumbler and field module
24 V DC
power
supply
Load feeders
with safe
AS-i outputs
G_IK10_XX_20027j
Example of a system configuration
Cost savings
Introduction
Industrial bus systems
IO-Link
1 ■ Overview
IO-Link
engineering: Visualization:
SIMATIC SIMATIC HMI
S7-PCT WinCC
Controller Controller
S7-300/ S7-1200
S7-400
PROFINET
IK10_30141c
Actuators system system sensors
RF200 RF200
Introduction
Industrial bus systems
IO-Link
■ Overview (continued)
1
Together for integrated quality
The requirements for integrated communication are increasing. At
the same time, the variety of field devices, actuators, and sensors
is increasing immensely – with ever greater intelligence.
IO-Link offers the solution for these requirements and is seen by
manufacturers as a valuable addition to the communications land-
scape (including AS-Interface).
As a committed driver of this issue, Siemens is further developing
not only its product and system range accordingly, but by inte-
grating IO-Link in Totally Integrated Automation, it is also provid-
ing a unique integrated communication solution.
Engineering
Reduced engineering times
• Standardized, open system for more flexibility (third-party
IO-Link devices can be integrated in the engineering)
• Uniform and transparent configuration and programming
through integrated engineering (SIMATIC STEP 7)
• Freely available function blocks for SIMATIC for user-friendly
parameterization and diagnostics, and read-out of measured
values
• Efficient engineering thanks to use of off-the-shelf faceplates in
SIMATIC HMI
• Low error rate in CAD circuit design thanks to reduction in
control circuit wiring
Commissioning
Reduced commissioning times
• Faster installation and minimized error rate thanks to reduction
in control circuit wiring
• Space savings in the control cabinet
• Low-cost wiring technology with several branches thanks to
unrestricted use of existing Siemens components
Operation and maintenance
Increased plant availability
• High level of transparency in the plant down to the field level
• Reduction of downtime and maintenance times through
plant-wide diagnostics and faster error correction
• Support for preventive maintenance
• High transparency through incorporation of energy manage-
ment systems, readout of current values, and diagnostic
messages
• Shorter conversion times thanks to central parameter and
recipe management for field devices as well
Introduction
Industrial bus systems
Industrial Wireless Communication
1 ■ Overview
Within the scope of industrial communication, wireless commu-
nications opens up new perspectives – from partial moderniza-
tion of a plant, right up to optimizing complex logistics or produc-
tion processes.
On the basis of Wireless Remote Networks, RUGGEDCOM WiN,
Industrial Wireless LAN and WirelessHART, Siemens offers solu-
tions for reliable automation with Industrial Wireless
Communication.
Wireless Remote
Networks
RUGGEDCOM WiN
Industrial Wireless
LAN
WirelessHART
G_IK10_XX_30229
Wireless Remote Networks – low-cost and versatile wireless Industrial Wireless LAN –
technology for longer distances flexible, plant-wide wireless infrastructure
Continuous communication between widely separated plant Wireless solutions are increasingly becoming a matter of course
sections in the area of water/wastewater, or high-speed remote in machines and plants. In the case of high data communication
maintenance access to machines and plants on the other side of requirements, Industrial Wireless LAN (IWLAN) backs innovations
the world - these are just two of the countless ways you can reap like deterministic radio and the Industrial Ethernet standard
the benefits of Wireless Remote Networks. Thanks to integration PROFINET. Thanks to the use of PROFIsafe via IWLAN, PROFINET
in a telecontrol system or an HMI/SCADA system, transferred opens up completely new perspectives – from efficient engineer-
process data is available at any time via mobile radio. ing, through real-time solutions, all the way to safety-related tasks.
Furthermore, an IWLAN infrastructure can also be used for addi-
tional applications such as video monitoring.
RUGGEDCOM WIN
WirelessHART –
RUGGEDCOM WiN products according to the wireless connection of the process instrumentation
IEEE 802.16e-2005 (WiMax) standard support longer distances
and are designed for use in critical locations or under demand- WirelessHART is an open industry standard, developed for the
ing environmental conditions. particular requirements of wireless communication for field de-
vices in the process industry. It meets all specific requirements
for reliability, security, economy and user-friendly operation sys-
tem-wide. With more than 30 million installed devices worldwide,
HART technology is the most frequently used communication
protocol for intelligent process instrumentation at the field level.
WirelessHART is backwards-compatible with the wired HART
technology and thus offers maximum investment security for
hardware, software and expertise.
Introduction
Industrial bus systems
Industrial Wireless Communication
■ Overview (continued)
1
IWLAN Controller
ANT795-6MT SCALANCE WLC711
ANT795-6MT AGV
SCALANCE
W748-1 RJ45
AGV
ANT795-6MT
SCALANCE
W748-1 RJ45
ANT795-6MT
W748-1
RJ45 AGV
W748-1
RJ45 AGV
SCALANCE SCALANCE
W786C-2 RJ45 W786C-2 RJ45
Container ship
G_IK10_XX_30273
AGV = Automated Guided Vehicle
Application example for controller-based IWLAN applications with a large number of access points, e.g. in a container terminal
Introduction
Industrial bus systems
Industrial Remote Communication
1 ■ Overview
Industrial Ethernet
PC with Telecontrol
Server Basic tunnel
GPRS
Internet
GPRS
dynamic dynamic
fixed IP address fixed IP address
IP address IP address
Communication
S7-1200 with CP 1242-7 S7-1200 with CP 1242-7 S7-1200 with CP 1242-7 S7-1200 with CP 1242-7
G_IK10_XX_30283
Station Station Station Station
Provider M2M Provider M2M Provider A Provider B
Efficient remote access to plants and machines with SIMATIC via industrial remote access
Global remote access to far-flung plants, remote machines and Teleservice is data exchange with physically remote technical
mobile applications is gaining in significance – both in industry plants (machines, plants, computers, etc.) for the purpose of er-
and in industry-related areas. With a comprehensive range of so- ror detection, diagnostics, maintenance, repair, or optimization.
lutions for industrial remote access, Siemens offers the ideal ba-
sis for efficient and reliable monitoring and control of widely dis- Telecontrol
tributed plants of any size.
Telecontrol involves the connection of distant process stations to
Secure and flexible access worldwide one or more central control systems. Various different public or
private networks (Remote Networks) can be used for communi-
Industrial plants are often distributed over large areas – some- cation for the purposes of monitoring and control. Event-driven
times even across national borders. Siemens offers proven solu- or cyclic exchange of process data is performed with special
tions for industrial remote access, such as flexible telecontrol telecontrol protocols and enables the operating personnel to
systems and efficient remote maintenance. Whether in public manage the overall process effectively.
infrastructure, the manufacturing or process industry: With com-
The telecontrol systems are based on SIMATIC. They supple-
prehensive solutions for teleservice and telecontrol, Siemens is
ment the SIMATIC system with corresponding hardware and
the right partner every time.
software, and thus permit individual process stations to be net-
worked over Remote Networks). The data for this is transmitted
via classical WAN, e.g. copper dedicated cable, dial-up net-
works, wireless, but also via IP-based networks such as mobile
wireless networks or the Internet.
Introduction
Industrial bus systems
Industrial Remote Communication
■ Overview (continued)
1
TeleControl Basic Control center systems
Telecontrol Basic connects the control center via the Telecontrol A number of different variants can be selected for setting up the
Server Basic control center software with the substations, control center depending on the process requirements and
consisting of SIMATIC S7-1200 controllers with CP 1242-7 or extent of the information:
CP 1243-1 GPRS module for Ethernet-based connections. • SINAUT ST7cc
The server also supports the connection of S7-200 stations with This WinCC-based PC control center is the ideal control center
MD720 modems. Wireless GPRS technology or IP-based net- system for both SINAUT ST7 and SINAUT ST1. It has been de-
works, such as DSL, are available as transmission media. An veloped specifically for event-driven and time-stamped data
S7-1200 substation permits remote communication with a con- transmission on the SINAUT system and can have a single or
trol center (service center) as well as direct slave-slave commu- redundant design.
nication with other S7-1200 substations. Small-scale applica-
tions with few outstations can be implemented, as well as large- • PCS 7 with PCS 7 TeleControl
scale plants comprising up to 5000 outstations. International This is the ideal control center system for plants in which larger
approvals permit worldwide use. local automation tasks have to be combined with telecontrol
connections. In addition to SINAUT ST7, remote stations with
Extended Telecontrol Server Basic functionalities allow the use other communication protocols can be connected, e.g. over
of telecontrol server services. The overall solution also includes DNP3 or IEC 870-5-101/-104.
the teleservice function and thus provides, for example, world- • WinCC TeleControl
wide access to the S7-1200 stations for international plant and This WinCC-based control center system offers the connec-
machine manufacturers. tion of SIMATIC substations to other telecontrol protocols such
as DNP3 or IEC 870-5-101/-104.
TeleControl Professional
• SINAUT ST7sc
TeleControl Professional comprises the Siemens telecontrol sys- This OPC server software is ideal for connecting the SINAUT
tems for extensive, expanded applications in the process indus- telecontrol system to control centers from other vendors via
try. Control systems such as PCS 7, WinCC and third-party con- OPC client function. ST7sc features extensive buffer mecha-
trol systems with OPC allow reliable control and monitoring of nisms which prevent data from being lost even if the OPC
outstations based on the SIMATIC S7-1200, S7-300 and S7-400 client fails, and it can have a single or redundant design
controllers. • SIMATIC S7 controller as control center
Like the substations, this control center comprises a SIMATIC
The outstations and substations can communicate with each S7-300 or S7-400 controller and is suitable for simpler appli-
other as well as with one or more control centers. cations requiring only one current process image of the tele-
control stations. The station process control can be influenced
Transmission networks
by entering commands, setpoints or parameters. The control
Telecontrol supports a wide variety of communication networks. center can also be used to extend a PC control center
In the classical WAN sector, these are: (SINAUT ST7cc or ST7sc), e.g. for data output on a panel, as
an emergency operating system, or for implementing cross-
• Dedicated lines (private or leased) station control tasks.
• Private radio networks (optionally with time slot procedure)
• Dial-up networks (analog, ISDN, GSM)
SIMATIC NET also offers appropriate modems for conventional
WANs. Communication, however, is also possible via Ethernet-
based WAN, namely:
• Via Internet connections, e.g. with SCALANCE M ADSL2+ routers
• Via 2-wire connections, e.g. with SCALANCE M SHDSL routers
• Via serial or Ethernet-based wireless systems, e.g. via UHF
radio devices or Industrial Wireless LAN with SCALANCE W or
RUGGEDCOM WiN (WiMax)
• Via fiber-optic conductors, e.g. through use of SCALANCE X
switches with optical ports; distances of up to 120 km can then
be covered
• Via mobile networks and the Internet using GPRS, GPRS(E) or
UMTS and DSL
There are no restrictions in terms of network combinations in a proj-
ect. Star, line and node topologies can be designed, and also mixed
configurations of these. A station can be linked using two transmis-
sion paths to permit redundant data transmission. The two paths
can be of the same type or also different, e.g. dedicated line com-
bined with telephone network or ISDN with DSL.
Introduction
Industrial bus systems
Industrial Remote Communication
1 ■ Overview (continued)
Teleservice / Remote Access
(remote diagnostics and remote maintenance) Field PG SCALANCE
M812-1
G_IK10_XX_30278
available, secured and economical data connections. TIM 3V-IE
Tablet Advanced
Depending on the application, SIMATIC NET provides the ap-
Station
propriate solution:
• For continuous connections or simultaneous access to several
Remote access via an UMTS-based Internet connection
plants, a solution via the Internet using SCALANCE S modules
is recommended, both on the service and the plant side.
Remote networks
• For flexible remote maintenance access from any Internet
connection – whether in the office, home office or hotel room –
Any type of remote communication is based on the public and
SOFTNET Security Client is the right software solution for con-
private networks used for this purpose (e.g. mobile radio or fixed
necting to the SCALANCE S Security Module installed in the
network), referred to as "remote networks".
plant.
• For plants without wired network connection, the M874-2 Under the name SCALANCE M, Siemens offers a comprehen-
sive range of high-performance transmission components, rout-
GPRS router establishes remote maintenance access to the
ers and modems that are tailored to the specific properties of the
SCALANCE S in the service center. respective remote networks or their transmission media and
• The SCALANCE M874-3 and M875 UMTS routers or the M812 therefore combine the maximum possible security with reliability.
and M816 ADSL routers are available for plants requiring re- Regardless of whether spontaneous or permanent transmission,
mote maintenance access at an especially high bandwidth whether high or moderate bandwidth, whether mobile or station-
ary – with the SCALANCE M products for IP-based connectivity,
In all cases, the communication is reliably protected by authen- users have a comprehensive spectrum of components at their
tication and encryption via a virtual private network (VPN) tunnel, disposal for remote access – flexible, optimized for industrial use
in order to rule out the possibility of industrial espionage or ma- and integrated into the TIA environment and into the Industrial
nipulation. Security concept. SCALANCE M devices can be used univer-
sally in the fields of telecontrol, teleservice (remote diagnosis
Siemens Remote Services and maintenance), and any other application for industrial re-
mote communication.
The teleservice product portfolio of Siemens is supplemented
with a service concept for SRS. "Siemens Remote Services" pro-
vides a powerful, secure platform for remote access to machines
and plants. The inclusion of "shared experts" ensures effective
support, not only from Siemens but also from the company's own
specialists.
Introduction
Industrial communication
Data for practical applications
■ Overview
1
Data for practical applications
Communication Systems Compared in Practice
Criteria
Data rate 10/100 Mbit/s 9.6 Kbit/s – 12 Mbit/s Send cycles 4.8/38.4 Kbit/s
1/10 Gbit/s adjustable 5 ms or
(only 100 Mbit/s for SIO (switching
PROFINET) 31.25 Kbit/s 1) operation)
DP/PA link
Length of the network Between two nodes: For the entire network: For the entire network:
electrical up to 100 m electrical up to max. electrical up to max. electrical up to 20 m
optical up to 5 km 10 km: 600 m:
(multimode) or up to - without repeater up - with extension plug
120 km (singlemode) to 1 km up to 200 m
- with repeater up to - with repeater or
10 km extender up to
optically with optical 300 m
link modules (OLM) up - with repeater and
to 1875 km extension plug up to
600 m
Topology Line Tree Ring Star Line Tree Ring Star Line Tree Star Point-to-point
G_IK10_XX_00004
Fail-safe communication PROFIsafe SIL3, PL e PROFIsafe SIL3, PL e ASIsafe SIL3, PL e –
1) For PROFIBUS PA
The table contains empirical values that can serve as recommendations for selecting the optimum network.
Introduction
Notes
1
PROFINET/Industrial Ethernet
Siemens IK PI · 2015
© Siemens AG 2014
PROFINET/Industrial Ethernet
Siemens IK PI · 2015
2
© Siemens AG 2014
Siemens IK PI · 2015
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet
Introduction
■ Overview
• Area and cell network according to the international standards • Comprehensive open network solutions can be implemented
IEEE 802.3 (Ethernet) and IEEE 802.11 a/b/g/h/n (wireless • High transmission performance at up to 10 Gigabit/s
LAN) designed for the industrial environment right down to the
field level • Integration of conventional IT functionalities such as Web
Telecontrol and
Laptop substation
PC control
Remote access,
e.g. via
teleservice
S7-1200 with
CP1242-7
Controller Numeric Control Controller
Control and Motion Control PC/PG/IPC
monitoring system Systems Database
Telecontrol and Server
substation control IWLAN
Controller Security
PROFINET
Industrial Ethernet
Access Access
Controller Point Point
Controller PC/PG IWLAN Industrial Ethernet
Notebook RCoax Cable Switches
Controller
Control and PC/PG/IPC
Numeric
Field device for monitoring system Control
intrinsically safe area
Wireless
Devices
Coupler
Link
PROFIBUS PA PROFIBUS
RF180C
ASM456 Field devices Code
Mobile reading
Panel systems
Field devices
SIMOCODE Mobile Drives
pro Panel IO-Link RFID
Code master Access
RFID system Point
system reading DP-Slave Motion Control
systems Systems
Link
IO-Link IO-Link Link
module module
Power Power
supply supply
Protection and
LOGO! Controller monitoring Client
SINAMICS devices Module
Compact Protection and RFID system Drives RFID system Compact
starter monitoring starter
devices
G_IK10_XX_50187
AS-Interface
Compact Compact
starter feeder Field device
Slaves Slaves
Signalling column
PROFINET/Industrial Ethernet
Industrial Ethernet
Introduction
■ Overview (continued)
Ethernet
The LAN standard from the office sector PROFINET
Ethernet currently has a market share of over 90% with a rising
trend, thus placing it in the pole position in the LAN landscape
worldwide. The specification of this baseband LAN was devel-
Industrial Ethernet 2
oped in the 70s and standardized in the international IEEE 802.3 Ethernet
standard. Ethernet has continued to experience rapid develop- conforming to
ment and established itself in all speed ranges and application IEEE 802.3
G_IK10_XX_10248
areas.
Milestones include:
• Almost unlimited and very easily scalable data transmission
performance thanks to
- switching technology, full duplex, redundancy
- continuously rising data rates (10/100 Mbit/s, 1/10 Gbit/s) PROFINET/Industrial Ethernet/Ethernet conforming to IEEE 802.3
• High availability of the network, because:
- existing networks can be expanded without any adverse Industrial Ethernet offers a powerful network, compliant with the
effects IEEE 802.3 standard (Ethernet), for industrial applications. This
- network structures with any form of meshing compensate for ensures that the widest range of application areas, such as
the failure of individual network components (e.g. by means office and production, can be networked with one another.
of the Rapid Spanning Tree Protocol) Industrial Ethernet utilizes Ethernet technology and strengthens
• Compatible protocol expansions, e.g. support of virtual it for use in the industrial sector by means of:
subnetworks and prioritized data traffic through the use of • Network components for use in tough industrial environments
VLANs (dust, moisture, extreme temperatures, impact loads, vibra-
• Structured cabling concept tions)
- Standardized connection technology • Rugged and simple connection technology for on-site
- Simplest connection technology due to use of preassembled assembly
twisted pair cables - FastConnect cabling system with RJ45 technology
- Glass fiber-optic cables for long distances, areas subject to - On-site assembly of POF and PCF fiber-optic cables
RFI and inter-building cabling
• Failsafe networks through redundancy
Ethernet forms the basis for overlaid network protocols such as • Failsafe devices through redundant design and redundant
TCP/IP. TCP/IP is responsible for the transport of data between power supplies
LANs and represents the basis for IT services (e.g. Internet).
In addition, this enables different LAN technologies to be easily • Connection of automation components (controllers and field
integrated, e.g. Ethernet with Wireless LAN. devices) to each other and to PCs and workstations
• Optimized communication between automation components
Ethernet components for the office sector are offered by a
and simultaneously open communication according to TCP/IP
large number of vendors, but do not always meets the specific
standard
requirements of the industrial sector.
• Simple connection to the Wireless LAN and Industrial Wireless
For planning, operation and maintenance of Ethernet networks, LAN (IWLAN) networks in accordance with IEEE 802.11
sufficiently qualified personnel are available worldwide.
• A security solution specially designed for industrial
Industrial Ethernet automation in the form of the Industrial Security concept
The industry-standard version of Ethernet. Among the Siemens Ethernet components for industrial use, the
focus is on compatible successor products and spare parts
The widespread use of Ethernet in the office sector and the availability of up to 10 years.
associated wide distribution of technology and know-how have
also made this technology interesting for the industrial environ-
ment. In order to adapt the networks for the sometimes extremely
harsh requirements in the industrial environment, Siemens has
made further drastic improvements to their industrial capability,
availability, reliability and real-time capability and added rugged
connection technology. This gave rise to the "Industrial Ethernet".
All Industrial Ethernet devices from Siemens are also extremely
easy to operate. This supports implementation without any
special IT knowledge.
By means of these additions for tough industrial use, Siemens
has shown that Ethernet can also be used successfully in such
applications. This approach has been consistently and success-
fully applied not only for Industrial Ethernet and PROFINET, but
also for Industrial WLAN.
PROFINET/Industrial Ethernet
Industrial Ethernet
Introduction
■ Overview (continued)
PROFINET PROFINET increases companies' success by accelerating
processes, boosting productivity, and increasing plant
The open Industrial Ethernet standard for automation availability.
With more than six million nodes worldwide (Dec. 2012),
2 PROFINET is the leading cross-vendor Industrial Ethernet
standard (IEC 61158/61784) for automation.
Advantages at a glance
G_IK10_XX_10304
Web tools Fast device replacement Redundancy
PROFINET/Industrial Ethernet
Industrial Ethernet
Introduction
■ Overview (continued)
Network diagnostics Even a single failure in the network during operation can result in
a rush of alarms from various network nodes which are con-
Failures in the network not only prevent access by plant opera- nected together. The combination of topology know-how with the
tors to the field devices, but often mean that these devices diagnostics values of individual network nodes is decisive in
2
can no longer communicate with one another. In the worst-case order to rapidly identify the location and eliminate the cause of a
scenario, this can result in production downtimes. With the network fault. A complete physical map of the network permits
SINEMA Server network monitoring software developed espe- analysis of the possible effects of cable or device faults. This is
cially for industry, problems can be detected and cleared at an helpful when planning high-availability applications.
early stage.
This established system, that has already been an essential
component of network availability in the IT sector for years, is
now also becoming a worthwhile addition to the production
environment.
The SINEMA Server software provides maximum transparency
in industrial networks through automatic topology recognition,
constant network monitoring as well as comprehensive diagnos-
tics and reporting functions.
The most important applications at a glance:
• Automatic documentation of networks:
Do you have up-to-date and complete documentation for your
networked automation system?
• Application-specific structuring and visualization of a network:
Do you have a simple, graphical overview of the devices in
your plant network?
• Reporting of changes and faults in the network:
The number of nodes of Ethernet-based devices in production Are you notified about new devices and network faults in plant
networks is growing continuously. Long, time-consuming operation?
searches for faults in large industrial networks during commis- • Analysis of changes and faults in the network:
sioning or during a standstill in production are unforeseeable Have you already had a plant standstill caused by a sporadic
cost drivers, to be avoided where possible. For this reason, network failure?
network transparency through the continuous diagnosis of • Integration of network diagnostics into HMI/SCADA:
Ethernet-based production networks should be part of every Can you also monitor the status of the network with your HMI
efficient production system. SCADA system?
However, with a suitable network management system, such • Adaptation of monitoring functionality to devices and users:
as SINEMA Server, which has been especially designed for Can you adapt your network diagnostics to the individual
industrial applications, problems can be detected at an early devices and the users?
stage and appropriate measures taken in good time.
■ More information
Further information on SINEMA Server Basic can be found at: For this reason, automation networks should be isolated from the
www.siemens.com/sinema remaining corporate network using appropriate security
products (e.g. SCALANCE S).
SINEMA Server V12 software (including 21 trial license);
download at: For further information, see the section on "Industrial Security".
http://support.automation.siemens.com/WW/view/en/74758725
It is important to note the boundary conditions for use of the
Note: specified SIMATIC Net products (order numbers 6GK..., 6XV1)
which you can view on the Internet.
In many SIMATIC NET components with a management function,
extensive parameterization and diagnostics functions are You will find more information on the Internet at:
provided over open protocols and interfaces (e.g. Web server, http://www.siemens.com/simatic-net/ik-info
network management).
These open interfaces provide access to those components,
which can also be used for illicit activities.
When the above-mentioned functions and the open interfaces
and protocols are used (e.g. SNMP, HTTP and Telnet), appropri-
ate security precautions must be implemented to suppress
unauthorized access to the components or network, especially
from the WAN/Internet.
PROFINET/Industrial Ethernet
Industrial Ethernet
Data communication
■ Overview
Standard communication OPC (Openness, Productivity & Collaboration)
This comprises standardized protocols for data communication. OPC is a standardized, open, and vendor-independent interface
that is widely used in automation. It permits the connection of
2
ISO, TCP/IP, UDP transport protocols OPC-capable applications using many different protocols such
ISO, TCP/IP and UDP are available as transport protocols. as S7-communication, PROFINET, and SNMP.
PROFINET/Industrial Ethernet
Industrial Ethernet
Communication overview
■ Overview
Ethernet
PROFINET IT communication Security Transport protocol Time Other
communication
PG/OP communication
S7 communication
Filetransfer server
Filetransfer client
TSend/TReceive
receive e-mail
ERP Connect
VPN (IP-Sec)
IRT real-time
IO Controller
send e-mail
Fetch/Write
SPI firewall
S7 routing
IO Device
IP routing
Receiver
Transfer
Sender
MRPD
SNMP
MRP
UDP
CBA
PRP
TCP
NTP
IPv4
IPv6
ISO
Hardware
SIMATIC
CP 243-1
S7-200
● ● ● ● ● ● ● ● ● ○
SIMATIC
S7-1200
S7-1200 CPUs ● ● ● ● ● ● ● ● ● ●
CP 1243-1 ● ● ● ● ●2) ● ● ● ● ● ● ○ ●
CPU 1511-1 PN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
SIMATIC S7-1500
CPU 1513-1 PN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
CPU 1516-3 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
PN/DP
CP 1543-1 ● ● ● ● ● ● ●2) ● ● ● ● ● ● ● ● ● ● ○ ● ● ● ●
CP 343-1 Lean ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 Adv ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 ERPC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
S7-400 PN CPUs ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
SIMATIC S7-400
CP 443-1 ● ● ● ● ● ○4) ● ● ● ● ● ● ● ● ● ●
CP 443-1 RNA ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
G_IK10_XX_10369
1) SMTP pass-through only ● applies
2) via S7-1200/1500 CPU ○ with reservations
3) Server (S) only
4) pass-through only
PROFINET/Industrial Ethernet
Industrial Ethernet
Communication overview
■ Overview (continued)
Open communication
S7 communication
Transport protocol
Operation system
Operation system
2
PROFINET
Hardware
Software
PG/OP
(64 bit)
(32 bit)
MRP
Time
OPC
IT
Windows 7 Professional / Ultimate + SP 1
8)
Vista Business / Ultimate + SP1/2
High-availability communication
Windows Server 2003 R2 / SP2
Windows Server 2008 + SP1/2
8)
Standard system
Windows 8 Pro
Windows 8 Pro
SEND/RECV
IO Controller
Fetch/Write
IO Device
SICLOCK
Linux
UDP
TCP
NTP
ISO
CP 1604
(PCI 104)
DK-16xx PN IO ● ● ● ● ●4) ○5) ● ● ● ● ●
CP 1616
(PCI 32 Bit)
HARDNET-IE S7 ● ● ● ● ● ● ● ● ● ● ● ● ● ○3) ○6) ● ● ● ● ●
(S7-1613)
CP 1613 A2
(PCI 32 Bit) HARDNET-IE
S7-REDCONNECT ● ● ● ● ● ● ● ● ● ● ● ● ○3) ○6) ● ● ● ● ● ●
(S7-REDCONNECT)
CP 1623
(PCIe x1) S7 OPC Redundancy ● ● ●
for Industrial Ethernet
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview
Network performance and network technologies Ethernet Switching
for Industrial Ethernet
The Industrial Ethernet switch has the following functionality:
When combined, the current Industrial Ethernet technologies • Depending on the number of available interfaces, switches
can significantly boost performance on the network in compari-
son with the original 10 Mbit/s technology. These technologies
are able to simultaneously interconnect several pairs of
subnetworks or stations temporarily and dynamically, with
2
are: each connection possessing the full data throughput.
• Fast Ethernet with 100 Mbit/s: • By filtering the data traffic on the basis of the Ethernet (MAC)
Compared to 10 Mbit/s, messages are transported much address of the terminals, the data traffic remains local and
faster and therefore only occupy the cable for an extremely only data intended for nodes of another subnetwork is
short time. For Fast Ethernet, a 4-wire FastConnect cabling forwarded by the switch.
system (Cat5e) is available with cable, plug and outlet.
• More data terminals can be connected than in a classic
• Gigabit Ethernet at 1 Gbit/s: Ethernet network.
As Gigabit Ethernet is faster than Fast Ethernet by a factor of
10, the cable is occupied for only one tenth of the time. • Error propagation is limited to the subnetwork concerned.
For Gigabit Ethernet, an 8-wire FastConnect cabling system The switching technology offers definite advantages:
(Cat6) is available with cable, plug and outlet.
• Subnetworks and network segments can be created.
• Gigabit Ethernet at 10 Gbit/s:
Compared to Ethernet with 1 Gbit/s, Ethernet with 10 Gbit/s is • The data throughput is increased and with it the network
faster again by a factor of 10. performance as a result of structuring the data communi-
cation.
• Full Duplex prevents collisions:
Data can be sent and received simultaneously between two • Easy rules for network configuration.
switches. The data throughput for a full-duplex connection • Unlimited extension of the network by connecting individual
therefore rises to 200 Mbit/s with Fast Ethernet and to 2 Gbit/s collision domains/subnetworks.
with Gigabit Ethernet. With full duplex, a greater length of the • Easy, reaction-free extension of existing networks.
network is possible. This means, for example, that when glass
fiber-optic cables are used, distances of up to 200 km can be Full duplex
achieved. Full duplex (FDX) is an operating mode in the network that, in
The data throughput increases enormously because the usual contrast to half duplex, allows stations to send and receive data
frame repetitions are avoided. simultaneously. When FDX is used, collision detection is auto-
• Switching reduces the network data traffic: matically deactivated in the participating stations.
The switch dynamically "connects" those stations that are
currently communicating. In the overall network, several For FDX, transmission media with separate send and receive
messages can therefore be en-route simultaneously. The gain channels must be used, e.g. FOC and TP, and the participating
in performance derives from the fact that several message components must be able to store data packages. With an FDX
frames can pass the switch simultaneously (as they are in connection collisions do not occur, so components that support
parallel). FDX can send and receive simultaneously at the nominal trans-
mission rate. The data throughput therefore increases to twice
• Autocrossover automatically crosses the send and receive the nominal transmission rate of the network, to 20 Mbit/s with
cables on Twisted Pair interfaces. the classic Ethernet and 200 Mbit/s with Fast Ethernet. With
• Autosensing describes the characteristic of network nodes Gigabit Ethernet, up to 2 000 Mbit/s are achieved.
(data terminals and network components) that automatically
detect the transmission rate of a signal (10 Mbit/s, 100 Mbit/s A further advantage of FDX is the increase in the network
or 1 Gbit/s) and support autonegotiation. extension.
• Autonegotiation is a configuration protocol on Fast Ethernet. By deactivating the collision principle, the distance between two
Before initiating the actual data transmission, network devices components can be increased by the size of a collision domain
automatically negotiate a transmission mode which is or more. With full duplex, the maximum distance can extend as
supported by any device (1 000 Mbit/s, 100 Mbit/s or far as the performance limit of the send and receive compo-
10 Mbit/s, full duplex or half duplex) nents. This is especially the case in connection with fiber-optic
cables. When glass fiber-optic cables are used, distances of
up to 200 km can be achieved between two switches.
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Autocrossover
Segment A Segment B Segment A Segment B The Autocrossover function automatically crosses the send
and receive cables on Twisted Pair interfaces. This means that
2
crossed connecting lines (e.g. TP XP Cords) are no longer
required.
High Speed Redundancy Protocol (HRP)
Extremely fast reconfiguration of the network following an error
is indispensable for industrial applications, because the con-
Segment C Segment D Segment C Segment D nected data terminals will otherwise disconnect logical commu-
nication links. This would result in a process running out of
control or emergency shutdown of the plant.
Switched LAN Shared LAN
In order to achieve the very fast reaction times required, various
• Each individual segment features • All nodes in the network share standardized procedures are used. A network can then be
the full performance/ the network performance/ reconfigured to form a functional network infrastructure again in
data rate data rate. a fraction of a second.
• Simultaneous data traffic in • All data packets pass through all
several segments, several segments. In an optical ring comprising 50 switches, the network will be
message frames at the same • Only one message in the network reconfigured after a fault (cable break or switch failure) in less
time at a time. than 300 ms.
• Filtering: Local data traffic
remains local; only selected data In addition to implementing high-speed media redundancy in
packets exceed segment the ring, Industrial Ethernet switches also offer the functions
G_IK10_XX_10002
Autosensing/Autonegotiation
Autosensing describes the characteristic of network nodes
(data terminals and network components) that automatically
detect the transmission rate of a signal (10 Mbit/s, 100 Mbit/s or
1 000 Mbit/s) and support autonegotiation.
Autonegotiation is the configuration protocol for Twisted Pair.
It enables the participating nodes to negotiate and agree the
transmission rate before the first data packages are transferred:
• 10 Mbit/s, 100 Mbit/s, 1 Gbit/s or 10 Gbit/s
• Full duplex or half duplex
Autonegotiation can also be deactivated if a specific trans-
mission rate has to be defined.
The advantage with Autosensing lies in the interoperability of all
Ethernet components.
Classic Ethernet components that do not support Autosensing
work together with Fast Ethernet and new Gigabit Ethernet
components that do support Autosensing.
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Operator Station PC
S7-1500
S7-300
2
S7-1500
SCALANCE
XM416-4C
PC
S7-400
S7-300
PC
SCALANCE
X204-2
PC
PC
S7-1500 S7-300
S7-400
G_IK10_XX_10093
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic) S7-400
S7-400
Operator Station PC
S7-400
S7-300
zjhshujlG
tT[WW
PC
S7-400
SCALANCE SCALANCE
X310 X310
S7-300
S7-300 with
SCALANCE X208 CP 343-1
S7-400 with
CP 443-1
S7-300
G_IK10_XX_10101
S7-400
Industrial Ethernet (Twisted Pair) S7-400
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Media Redundancy Protocol (MRP)
A further option for attaining greater system availability is PRO- If the ring is interrupted at one point, immediate reconfiguration
FINET MRP. The media redundancy can be created on the one takes place and all communication nodes continue to be acces-
2
hand by means of switches, and on the other hand direct via the sible.
PROFINET interfaces on SIMATIC controllers and distributed in-
puts/outputs. Thanks to the MRP protocol (IEC 61158 Type 10),
reconfiguration times of less than 200 ms can be achieved, de-
pending on the number of stations.
S7-400
S7-300
S7-400
S7-300
SCALANCE
X204-2
PC
S7-400
SCALANCE SCALANCE
X208 X208
S7-300
SCALANCE SCALANCE
X208 X208
IPC
PC
SCALANCE S7-400
IPC
X101-1 or X101-1LD
G_IK10_XX_10054
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
SCALANCE
Access Point
W788-1 M12
Field PG
G_IK10_XX_10056
Optical star topology with SCALANCE X101-1/X101-1LD and remote SCALANCE W Access Point
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Seamless redundancy
For some applications with particularly high requirements in PG/PC/IPC Server
terms of the reconfiguration time, there is the possibility of
2
setting up a redundant network without any reconfiguration time
at all (seamless redundancy).
For this purpose, PROFINET offers the MRPD standard (Media SCALANCE SCALANCE
X204RNA X204RNA
Redundancy for Planned Duplication). This method is based on
the topology-optimized IRT communication.
Two other solutions that can be used are High-availability
Seamless Redundancy (HSR) and Parallel Redundancy Proto-
col (PRP) of the IEC 62439-3 standard. Industrial Ethernet
All methods facilitate networks that continue to function in the
event of a fault (e.g.: cable break) WITHOUT interruption. This is
achieved by duplicating the data packets at the sender and then SCALANCE SCALANCE
transmitting them to the recipient over two different paths. X204RNA X204RNA
EEC
G_IK10_XX_10343
PC
Industrial Environment with a
Ethernet high EMC load, e.g.
(LAN A) low-voltage and
1) high-voltage switchgear
High-availability Seamless Redundancy Protocol
Industrial
Ethernet SCALANCE
(LAN B) Bumpless, ring-shaped network with HSR redundancy procedure
X204RNA
EEC
Redundancy with the Spanning Tree algorithm
SIMATIC PC
Environment with a
of closed meshes different connections are switched to standby
S7-400 with so that an open tree structure results from the meshed structure.
CP 443-1RNA high EMC load, e.g.
low-voltage and For this purpose, switches communicate with each other using
1) high-voltage switchgear the Spanning Tree Protocol. This protocol is extremely complex
Parallel Redundancy Protocol
because it has to handle any type of network structure.
Bumpless, parallel networks with PRP redundancy procedure The organization of network structures with the Spanning Tree
protocol can take from 30 to 60 seconds. During this period, pro-
ductive communication for reliable visualization or process con-
trol in the network is not possible.
In the time-optimized variant "Rapid Reconfiguration Spanning
Tree“ according to IEEE 802.1, the time is shortened to between
1 and 3 seconds for up to 10 series-connected switches.
Due to the comparatively long reconfiguration time, this protocol
is used predominantly in office networks. For connecting to such
office networks, some SIMATIC NET switches support the Rapid
Spanning Tree Protocol.
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Switched network Optical cabling with POF/PCF or glass fiber optic cable
Switched industrial networks can be configured electrically or Fiber-optic cables are always recommended as an alternative
optically with a linear, star or ring structure, or a combination. to copper cables in environments subject to strong electro-
2
magnetic interference (EMI) if reliable equipotential bonding
They are constructed with SCALANCE X switches and with cannot be guaranteed, or if the system is in the open air.
switches integrated into terminal devices, e.g. in communica-
tions processors. Glass fiber optic cables are used for data transmission over long
distances, while for shorter distances, plastic fiber optic cable
As the transmission medium between the switches and for con- made of light-conducting plastics like polymer optical fiber
nection to the terminal devices electrical cables (e.g. twisted (POF), or plastic covered glass fibers such as polymer cladded
pair cables) or fiber optic cables are used. fiber (PCF), are used.
Switched networks can be of any size. In networks of a larger Simple fiber-optic cabling for machine-level use is implemented
scale (depending on the application) the signal delays are to be with the SC RJ connection system for polymer optical fiber and
considered. PCF. The SC RJ connectors can be assembled especially
quickly and simply on-site. The plastic fiber optic cables de-
signed for this purpose can be used universally or specifically in
festoon cable systems.
For optical cabling, e.g. for a PROFINET system, products with
POF or PCF connection are used, e.g. the Industrial Ethernet
Switch SCALANCE X200-4P IRT, ET 200S distributed I/O, or the
SCALANCE X101-1POF media converter.
l{GYWWzG
wyvmpul{ plGG wvmTmvj ptGX\XTZGwuGmv
pGl
zjhshujl zjhshujl zjhshujl
YW[py{ YWYTYwGpy{ YWWT[wGpy{
l{GYWWzG
ptGX\XTZGwuGmv
nprXWXWX^]
l{GYWWzGGptGX\XTZGwuG
Mixed network with SCALANCE X202-2P IRT and SCALANCE X101-1POF media converter
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Fault-tolerant communication
The availability of the communication is increased by means of Fault-tolerant S7-connections can be set up from S7-400H
redundant communication connections, to which the data trans- stations to
2
mission can be switched quickly in the event of a fault. • Other H stations (one- or two-channel)
• PCs (S7-REDCONNECT software required)
PC/IPC with
2x CP 1613 A2
or CP 1623
and S7-REDCONNECT
Industrial Ethernet
G_IK10_XX_10251
H-CPU in single mode
z^T[WWGGjwG z^T[WWGGjwG z^T[WWGGjwG
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Enterprise Level
2 1000 Mbit/s
Ethernet
Control Level WinCC
SCALANCE SCALANCE
XM416-4C XM416-4C Server
IPC with with
Gigabit interface SCALANCE CP 1623
and CP 1616 XM408-8C
SCALANCE 1000 Mbit/s
X308-2M PoE 1000 Mbit/s
IP camera SCALANCE
X308-2
1000 Mbit/s 1000 Mbit/s
SIMATIC S7-400
with 1000 Mbit/s
CP 443-1 Advanced
Field Level
100 Mbit/s PROFINET
Industrial Ethernet
G_IK10_XX_10226
ET 200S S7-300 with ET 200S ET 200pro ET 200SP S7-300 with
Drives CP 343-1 Lean CP 343-1 Lean
Network separation between field level and control level including Gigabit communication at the control level
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
SIMATIC PCS 7 process control system with Gigabit
In the control room, two SCALANCE X-400 switches are used on Several operator panels are provided and divided between
the terminal bus. If a high number of nodes are connected to the the two switches so that the system can still be operated in the
2
plant bus, SCALANCE XR-500 or XM-400 switches, for example, event of a failure. The terminal and plant buses are connected
can be used with port extenders. These are connected together using redundant servers, e.g. with SCALANCE X408-2 also via
to create an electrical ring with a transfer rate of 1 Gbit/s. high-performance Gigabit lines.
SCALANCE
X310
OS Server OS Server
Industrial Ethernet (redundant) 1000 Mbit/s (redundant)
(electrical)
SCALANCE SCALANCE
XM 408-8C XM 408-8C
Industrial Ethernet Plant Bus
(optical)
SCALANCE
IPC 1000 Mbit/s
XM 416-4C
SCALANCE
X308-2
SCALANCE XM 416-4C
SCALANCE Human machine
XM 416-4C interface
G_IK10_XX_10183
ET 200M ET 200M
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Management Level Server Server Server Server
2
Server
1000 Mbit/s 1000 Mbit/s
10 Gbit/s 10 Gbit/s
SCALANCE SCALANCE
XR-500 OSPF XR-500
PC
Ring redundancy
Operator Station PC
10 Gbit/s
Industrial Ethernet
Engineering Station
SCALANCE
SCALANCE SCALANCE XR-300 SCALANCE XR-300
XM-400 XM-400
ET 200SP
G_IK10_XX_10298
SCALANCE XR-300 SCALANCE SCALANCE
1000 Mbit/s X-300 1000 Mbit/s X-300
Plant network with connection to the management level or the corporate network with SCALANCE X-500
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
Fail-safe wireless communication with PROFIsafe
For several years, safety engineering has been integrating into PROFIsafe prevents errors such as address corruption, loss,
standard automation on the basis of SIMATIC S7 controllers, delay, etc., when transmitting messages through continuous
2
PROFIBUS and PROFIsafe. numbering of the PROFIsafe data, time monitoring, and authen-
ticity monitoring using passwords and optimized cyclic redun-
This range has been expanded by PROFINET-enabled compo- dancy check (CRC).
nents, thus providing a complete product range with failsafe
controllers, failsafe I/O and a corresponding engineering envi-
ronment.
PROFINET PROFIsafe
Proxy
HMI
SINAMICS Drives
PROFIsafe
SINUMERIK DP/AS-i
840D sl and F-Link
SINAMICS
other field busses S120 Drives
G_IK10_XX_30118
SINAMICS
G120
AS-Interface Distributed I/O
Coupling of networks
For a high-performance coupling of networks, the modular
Industrial Ethernet Switch SCALANCE XM-400 is available.
In the case of SCALANCE XM-400, high-speed IP routing
permits communication between different IP subnetworks and
routers. Methods supported for this include:
• Static routing
• Dynamic routing OSPF (open shortest path first) and
• RIPv1/2 (routing information protocol)
• Redundant routing VRRP (Virtual Router Redundancy
Protocol)
PROFINET/Industrial Ethernet
Industrial Ethernet
Topologies
■ Overview (continued)
PC/IPC with
CP 1613 A2/
CP 1623
2
SCALANCE SCALANCE
XM 416-4C XM 416-4C
PC/IPC with
CP 1613 A2/
CP 1623 MP 377
S7-300 with
CP 343-1 ET 200S ET 200S ET 200S
G_IK10_XX_10252
Robots
PROFINET/Industrial Ethernet
Industrial Ethernet
Network selection criteria
■ Overview
Twisted pair network Fiber optic network Wireless network
Inter-building networking
● ● ● ○ 1)
○○○○
● ● ● ● 1)
●●●
●●○○
●●○
2
EMC ●●●○ ●●● ●●●
Performance spectrum for special Cables for indoor area; trailing Cables for indoor and outdoor area; ─
applications cable; marine cable; FastConnect trailing cable; halogen-free cable
cables
Effect of voltage failure Failure of a subnetwork 2) Failure of a subnetwork 2) Failure of a subnetwork 2)
Effect of path failure Network breaks down into two sub- Network breaks down into two sub- ─
networks functioning in isolation 3) networks functioning in isolation 3)
Max. network expansion 5000 m 4) Up to 150 km 4); ─
over 150 km, consider signal propa-
gation time
Max. distance between two network 100 m 50 m POF 30 m indoors per segment
nodes / Access Points 100 m PCF 100 m indoors per segment
4000-5000 m multimode
120 km single mode
Pre-assembled cables Yes Yes ─
Assembly on site without special tool; without special tool; ─
FastConnect technology FastConnect technology
Integrated diagnostics support LED indicators; signaling contact; LED indicators; signaling contact; LED indicators;
SNMP network management; SNMP network management; SNMP network management;
Web-based management, Web-based management, Web-based management,
PROFINET diagnostics PROFINET diagnostics PROFINET diagnostics
Redundant network structures Electrical ring or doubling of the Optical ring or doubling of the infra- Multiple illumination or use of
infrastructure (linear, star, tree) structure (linear, star, tree) different frequency bands
(2.4 and 5 GHz)
G_IK10_XX_10013
1) suitable for 10 Mbit/s to 10 Gbit/s ● ● ● ● suitable
2) Safeguard against subnetwork failure by means of redundant voltage supply ● ● ● ○ partly suitable
3) no effect in the case of ring structure
4) if there are 50 switches in the ring
●●○○
●○○○
○ ○ ○ ○ not applicable
PROFINET/Industrial Ethernet
PROFINET
Introduction
■ Overview
PROFINET – the Ethernet standard for automation PROFINET increases companies' success by accelerating
processes, boosting productivity, and increasing plant
PROFINET is the leading Industrial Ethernet standard with more availability.
than 5.8 1) million nodes worldwide.
2
1)
Source: PROFIBUS & PROFINET International (PI) Edition 2013
Advantages at a glance
G_IK10_XX_10304
Web tools Fast device replacement Redundancy
Flexibility
Short response times and optimized processes are prerequisites The PROFINET network can be installed without any specialist
for competitiveness in global markets, because product life- knowledge and meets all requirements relevant to the industrial
cycles are becoming shorter and shorter. environment. The PROFINET Guideline "Cabling and Inter-
connection Technology" provides network installation support
PROFINET ensures maximum flexibility in plant structures and for manufacturers and users. Symmetrical copper cables or
production processes, and it enables you to implement innova- RFI-resistant fiber-optic cables are used depending on the
tive machine and plant concepts. Mobile devices, for example, application. Devices from different manufacturers are easily
can be integrated into relatively inaccessible locations. connected via standardized and rugged plug-in connectors
IWLAN (up to IP65/IP67).
PROFINET also supports wireless communication with Industrial Thanks to the integration of switch functionality into the devices,
Wireless LAN and thus opens up new application fields. linear topologies can be formed that are configured based on an
For example, technologies subject to wear such as contact wires existing machine or plant structure. This results in savings in
can be replaced and automated guided vehicle systems and cabling overhead and cuts down on components such as exter-
mobile operator panels can be used. nal switches.
Safety Open standard
The PROFIsafe safety profile, which has been tried and tested PROFINET, the open vendor-independent standard
with PROFIBUS and which permits the transmission of standard (IEC 61158/61784), is supported by PROFIBUS and PROFINET
and safety-related data on a single bus cable, can also be used International (PI). It stands for maximum transparency, open
with PROFINET. No special network components are required IT communication, network security and simultaneous real-time
for fail-safe communication, standard switches and standard communication.
network transitions can be used without restrictions. In addition, Due to its openness, PROFINET creates the basis for a uniform
fail-safe communication is equally possible via Industrial automation network in the plant to which all of the machines and
Wireless LAN (IWLAN). devices can be connected. The integration of existing parts of
Flexible topologies the plant, using PROFIBUS for example, can also be achieved
without any problems through the use of network transitions.
PROFINET also enables the use of star, tree, and ring topologies
in addition to the linear topology characterized by the estab-
lished fieldbuses. This is made possible by means of switching
technology via active network components, such as Industrial
Ethernet switches and media converters, or by integrating
switch functionality into field devices. This results in an
increased machine and plant planning flexibility, as well as
savings in cabling.
PROFINET/Industrial Ethernet
PROFINET
Introduction
■ Overview (continued)
Efficiency
Global competition means that companies must deploy their
resources economically and efficiently. This applies in particular
2
to production. PROFINET ensures more efficiency here.
PROFINET Simple engineering guarantees fast commissioning, and reliable
devices enable high plant availability. Comprehensive diagnos-
Industrial tics and maintenance concepts help to reduce plant downtimes
Ethernet and maintenance costs to a minimum.
IE/PB One cable for all purposes
Link
PN IO PROFINET permits simultaneous fieldbus communication in
isochronous mode and standard IT communication (TCP/IP) via
IE/AS-i one cable. This real-time communication for the transmission
LINK of user/process data and diagnostic data is performed on a
PN IO single cable. Specific profile communication (PROFIsafe,
PROFIdrive and PROFIenergy) can be integrated without addi-
tional cabling overhead. This solution provides a wide range of
G_IK10_XX_30117
PROFIBUS functions with a low degree of complexity.
Device and network diagnostics
AS-Interface
By retaining the field-proven PROFIBUS device model, the same
diagnostic information is available with PROFINET. In addition,
device diagnostics also includes read-out of module-specific
Fieldbus integration via a proxy and channel-specific data from the devices. This enables simple
and fast location of faults. In addition to the availability of device
Use of web tools information, the top priority in network management is reliability
of network operation.
PROFINET's unrestricted support for TCP/IP permits the use
of standard web services such as web servers in the device. The Simple Network Management Protocol (SNMP) has become
Independently of the tool used, information from the automation established in existing networks as the de-facto standard for the
level can be accessed from almost anywhere at any time using maintenance and monitoring of network components and their
a commercially available Internet browser. This considerably functions. PROFINET uses this standard and provides users with
simplifies commissioning and diagnostics. the option of servicing networks using familiar tools such as the
SINEMA Server network management software.
Each user can decide for himself how much openness to the
IT world he will permit for his machine or plant. Thus, PROFINET In order to facilitate the maintenance of PROFINET devices,
can be easily operated as an isolated plant network or it can be both locally and also remotely via a secure VPN connection,
connected to the office network or the Internet via suitable secu- application-specific Web sites in the familiar HTML standard can
rity modules, such as the SCALANCE S modules. This allows be created on the integral Web server of the field devices.
new teleservice concepts or even the fast exchange of produc-
tion data.
Expandability
On the one hand, PROFINET permits the easy integration of
existing systems and networks without great effort. Thus,
PROFINET protects the investments in existing plant units which
communicate via PROFIBUS and other fieldbuses such as
AS-Interface, for example.
On the other hand, additional PROFINET stations can be added
at any time. Network infrastructures can be expanded using
additional network components, both wired and wireless ver-
sions, even during operation.
PROFINET/Industrial Ethernet
PROFINET
Introduction
■ Overview (continued)
Energy efficiency Easy cabling
Moving toward the green factory: PROFIenergy Stringent demands are placed on the installation of cables in
the industrial environment. There is also the requirement to set
PROFIenergy is a profile that provides functions and mecha-
2
up error-free industry-standard networks in the shortest possible
nisms for PROFINET field devices that support energy-efficient time without specialist knowledge.
production.
Siemens offers FastConnect, a system that meets all these re-
The vendor and device-independent profile defined by PNO al- quirements: FastConnect is the standards-compliant, industry-
lows the user to significantly reduce the energy consumption standard cabling system consisting of cables, connectors, and
and costs: PROFIenergy enables specific loads that are not re- assembly tools for PROFINET networks.
quired to be switched off. This noticeably reduces energy costs
during pauses in production. PROFIenergy facilitates automated The time spent for connecting the terminal devices is minimized
activation and deactivation of technologically related plant sec- thanks to the easy installation using only a single tool, and instal-
tions. The coordination is performed centrally by means of a lation errors can be avoided thanks to the practical color-coding.
higher-level controller, and the networking via PROFINET. This Both copper cables and glass fiber-optic cables can be assem-
means that during long pauses, as much energy as possible is bled on-site in this way.
saved. Plant sections that are switched off for short periods con-
tribute to the even distribution and most efficient use of energy. Fast device replacement
The use of PROFIenergy is made easier for the machine builder PROFINET devices are identified via a name that is assigned in
by its integration into well-known series of products. In addition, the configuration. When replacing a defective device, a new
PROFIenergy is defined in such a way that the necessary func- device can be recognized by the IO Controller by means of
tion blocks can be integrated into existing automation systems topology information and have a name automatically assigned to
at a later date. it. An engineering tool is therefore not required when replacing
devices.
This mechanism can also be used during the initial commission-
ing of a complete plant. Quick commissioning is thus especially
possible for series machines.
Ruggedness
An automation network must be able to withstand most external
G_IK10_XX_10305
PROFINET/Industrial Ethernet
PROFINET
Introduction
MRPD
■ Overview (continued)
High network availability can be achieved without reconfigura-
Performance
tion time using the PROFINET-compatible MRPD procedure
Productivity and product quality determine market success. (Media Redundancy for Planned Duplication). The MRPD proto-
Precise motion control, dynamic drives, high-speed controllers, col is an extension to the MRP protocol for sending message
2
and the deterministic synchronization of devices are therefore frames in duplicate within a ring topology. Networks can only be
key factors in achieving superior production. They allow high constructed with SCALANCE X-200IRT switches and additional
production speeds and simultaneously optimized product components with the real-time feature Isochronous Real-Time
quality. IRT (PROFINET standard), such as SIMATIC controllers, ET 200,
SIMOTION and SINAMICS drives.
Speed and precision
Fast start-up
Fast motion control applications need precise and deterministic
data exchange. This is implemented thanks to isochronous drive The Fast Start-Up function allows rapid start-up of PROFINET IO
controls using Isochronous Real-Time (IRT). Devices that are connected to SIMATIC Controllers. The commu-
nication connection between the controller and the device is
PROFINET permits high-speed and deterministic communica- established in less than a second. For modular plants, individual
tion due to IRT and isochronous mode. The different cycles of a plant parts can therefore be connected or disconnected in the
system (input, network, CPU processing and output) are also shortest time. For example, the tool change can be accelerated
synchronized in the case of parallel TCP/IP traffic. PROFINET's significantly in robot applications.
short cycle times make it possible to increase the productivity of
machines and plants, and to ensure product quality through high
precision. ■ Benefits
The standardized PROFIdrive drive profile enables vendor- • PROFINET is the open Industrial Ethernet standard for
independent communication between CPUs and drives. automation
• PROFINET is based on Industrial Ethernet
Large quantity structures
• PROFINET uses TCP/IP and IT standards
Previous limitations in the scope of the machines and systems
to be implemented can be easily overcome through the use of • PROFINET is Real-Time Ethernet
PROFINET. With PROFINET, up to 256 field devices can now be • PROFINET permits seamless integration of fieldbus systems
managed by one SIMATIC Controller. • PROFINET supports fail-safe communication via PROFIsafe
In a network, several controllers can interact with their assigned over IWLAN as well
field devices. The number of field devices per PROFINET net-
work is virtually unlimited – the entire band of IP addresses is
available.
High transmission rate
By using 100 Mbit/s in full duplex mode, PROFINET achieves a
significantly higher transmission rate than previous fieldbuses.
Thanks to this, both the process data and other plant data can
be transferred via TCP/IP without any problems. In this way,
PROFINET combines the industrial requirements of simultane-
ously transferring fast IO data and large data quantities for other
parts of the application. Even the transfer of large quantities of
data such as by cameras does not affect the speed and the pre-
cision of the IO data transfer thanks to PROFINET mechanisms.
Redundancy
Higher plant availability can be achieved by means of a redun-
dant installation (ring topology). The media redundancy can be
implemented both with the help of external switches and direct
via integral PROFINET interfaces. Reconfiguration times of
200 ms can be achieved. In the case of an interruption to the
communication in only one part of the ring installation, this
means that a plant standstill is prevented and the necessary
servicing and repair work can be carried out without time
pressure.
PROFINET/Industrial Ethernet
Cabling technology
Overview of passive network components
■ Overview
Industrial Ethernet Maximum cable lengths for industrial Ethernet connections
Type of fiber 0 - 10 m 0 - 50 m 0 - 55 m 0 - 85 m 0 - 100 m 0 - 750 m 0 - 4.000 m 0 - 5.000 m 0 - 26.000 m
2
IE FC cables 2x2 at 100 Mbit/s
FC RJ45 outlet with 2x2 cable
(additional 10 m patch cable can
•
(0 - 45 m;
•
(0 - 75 m;
•
(0 - 90 m;
be connected in total)
Torsion Marine/Traling/ Standard
Cable) Flexible/ Cable GP)
FRNC/Food/
Festoon
Cable)
Patch cable ●
TP FC Standard Cable GP 2x2 ●
TP Ground Cable 2x2 ●
TP Train Cable GP 2x2 ●
TP FC Flexible Cable GP 2x2 ●
TP FC Marine Cable 2x2 GP ●
TP FC Trailing Cable 2x2 ●
TP FC Trailing Cable GP 2x2 ●
TP Torsion Cable 2x2 ●
TP FC FRNC Cable GP ●
TP FC Food Cable ●
TP FC Festoon Cable GP ●
IE FC cables 4x2 at 1000 Mbit/s
Multimode
FO Standard Cable GP
(50/125) • 2)
• 1)
Multimode
FO Ground Cable
(50/125) • 2)
• 1)
Multimode
FO Trailing Cable
(50/125) • 2)
• 1)
Multimode
FO Trailing Cable GP
(50/125) • 2)
• 1)
Multimode
FO Robust Cable GP
(50/125) • 2)
• 1)
Multimode
INDOOR FO Cable
(62,5/125) • 1)
Multimode
FO Standard Cable
(62,5/125) • 1)
Multimode
Flexible FO Trailing Cable
(62,5/125) • 1)
Multimode
FO Robust Cable GP 3)
(4E9/125) • 1)
POF
POF Trailing Cable 980/1000
(980/1000) • 1)
PCF
PCF Standard Cable GP
(200/230) • 1)
PCF
PCF Trailing Cable
(200/230) • 1)
• 1)
IP67
PRO
power
Devices
Devices
connector
Plug 4x2
Plug 2x2
with M12
connector
with RJ45
connection
connection
7/8“ plug-in
IE FC RJ45
IE FC RJ45
IE FC RJ45
4x2
2x2
■ Overview (continued)
Modular Outlet
hybrid connector
X-coded
A-coded
IE FC RJ45 Plug
Power Plug PRO
IE FC Outlet RJ45
IE FC Standard Cable GP 4x2 (AWG22)
●
IE FC Standard Cable GP 4x2 (AWG24)
●
IE FC Flexible Cable GP 4x2 (AWG24) IE FC Cable 4x2
● ●
IE FC TP Standard Cable GP 2x2
IE FC TP Flexible Cable GP 2x2
IE FC TP FRNC Cable GP 2x2
IE FC TP Trailing Cable GP 2x2
IE FC TP Trailing Cable 2x2
IE FC TP Festoon Cable GP 2x2
●
●
●
●
IE FC Cable 2x2
IE TP Torsion Cable 2x2
IE FC TP Food Cable GP 2x2
IE FC TP Marine Cable 2x2
IE Train Cable GP 2x2
IE Ground Cable 2x2
IE TP Cord 9/RJ45
IE TP XP Cord 9/RJ45
IE TP Cord 9-45/RJ45
IE TP XP Cord 9-45/RJ45
●
●
IE TP Cord 2x2
IE TP Cord RJ45/15
IE TP XP Cord RJ45/15
IE TP XP Cord 9/9
© Siemens AG 2014
IE TP Cord RJ45/RJ45
●
●
●
IE TP XP Cord RJ45/RJ45 IE TP Cord 4x2
electrical
●
PLUG-180 Cable RJ45
Options for connecting Industrial Ethernet cables with plugs, terminals ordevices (IE)
M12-180/M12-180 IE Connecting
M12-180/IE FC RF45 PLUG-145 Cable M12
●
●
Hybrid cable
Siemens IK PI · 2015
Hybrid cable 2x2 + 4x0,34
●
Energy Cable
●
●
Energy Cable 5 x 1,5
2/29
G_IK10_XX_10245
Overview of passive network components
Cabling technology
PROFINET/Industrial Ethernet
2
2
2/30
Plug
Plug
BFOC
with SC
SC plug
connector
Plug PRO
Plug PRO
Multimode
IE devices
IE devices
IE devices
■ Overview (continued)
FO FC SC
with BFOC
connection
connection
connection
with SC RJ
SC RJ plug
FO LC Plug
FO LC Plug
Singlemode
Cabling technology
FO FC BFOC
IE SC RJ PCF
IE SC RJ POF
FO Standard Cable GP
Siemens IK PI · 2015
FO Trailing Cable Fiber-optic cable
●
●
FO Trailing Cable GP 50/125/1400 μm
FO Ground Cable
●
●
Flexible Fiber Optic trailing cable 62.5/125 μm
SIENOPYR marine duplex fiber
Overview of passive network components
opticcable
●
●
PCF Trailing Cable GP
PCF Trailing Cable cable 200/230 μm
Fiber-optic cable
Preassembled FOC with
●
with
BFOC plug BFOC connector
© Siemens AG 2014
Fiber-optic cable
●
Preassembled FOC with SC plug
with SC plug
Optical
●
POF Trailing Cable 980/1000 μm
Options for connecting Industrial Ethernet cables with plugs, terminals or devices
Fiber-optic cable
●
Preassembled FOC with SC RJ plug with SC RJ plug
FO Robust Cable GP
●
(4E9/125/900)
Fiber-optic cable
with LC plug
FO Robust Cable GP
●
(50/125/900)
FO FC Standard Cable GP
(62,5/200/230)
Fiber-optic cable
with FC plug
● ●
● ●
FO FC Trailing Cable
G_IK10_XX_10246 (62,5/200/230)
© Siemens AG 2014
PROFINET/Industrial Ethernet
Cabling technology
Overview of Twisted Pair
■ Overview ■ Application
Structured cabling 10/100 Mbit/s 10/100/1 000 Mbit/s
• Structured cabling to ISO IEC 118011/EN 50173 describes the IE FC TP Cable 2x2 • –
non-application-specific, tree-like cabling of building
IE FC TP Cable 4x2 – •
2
complexes for IT purposes. A site is subdivided into the
following areas: IE FC RJ45 Plug 2x2 • –
- Primary area (connecting the buildings of a site) IE FC M12 Plug PRO 2x2 • –
- Secondary area (connecting the floors of a building)
- Tertiary area (IT connection of data terminals on a floor) IE FC RJ45 Plug 4x2 – •
IE FC M12 Plug PRO 4x2 – •
The structured cabling that can be achieved with the Industrial
Ethernet FastConnect System corresponds to the structure of IE FC Outlet RJ45 • –
the tertiary cabling in accordance with EN 50173 for Ethernet. IE FC RJ45 Modular Outlet – •
FastConnect Twisted Pair (FC) IE TP Cord •1) •2)
• For structured cabling in the production hall, the FastConnect IE Connecting Cable • –
Twisted Pair cabling system is ideal (RJ45 and M12 connec- 1)
All TP Cord types with a Sub D interface
tions). With the fast installation system for Industrial Ethernet, 2)
structured cabling from the office environment not only IE TP Cord RJ45/RJ45 and IE TP Cord XP
becomes industry compatible for installation in the production UL approvals
hall;
UL listing (safety standard) for network cables is especially
• FastConnect cables can also be assembled extremely quickly necessary for the American and Canadian markets. The require-
and easily on site. The RJ45 cabling technique, an existing ments for the appropriate approvals depend on where the cable
standard, is also available in an industry-standard version is routed within the building. This applies to all cables which
that supports structured cabling (patch cables, patch field, have to be routed from a machine to a remote control cabinet
installation cables, connection socket, connecting cable). and are positioned on cable racks secured on the building.
• With the FastConnect plugs and FastConnect cables as an Cables with UL approval have "GP" (General Purpose) added to
alternative to structured cabling, up to 100 m cable length can their name.
be achieved for a point-to-point link (requires less patch
technology).
■ Design
■ Benefits The FastConnect system comprises:
• Extensive product range for flexible cabling in industry • Industrial Ethernet FastConnect cables specially designed
for fast connection (UL and CAT5e certified) as FC TP
• Faster connection of data terminals thanks to safe stripping of Standard, FC TP Flexible, FC TP Trailing, TP Torsion, FC
the outer sheath and braided shield in one step Ground Cable, FC Food Cable, FC FRNC Cable, FC Festoon
• Easy connection method (insulation-piercing contacts) for Cable and FC TP Marine Cable.
4-core (Cat5) and 8-core (Cat6) Industrial Ethernet FC Twisted • Easy stripping with the FastConnect Stripping Tool; the
Pair installation cables outer sheath and the braided shield are stripped accurately in
• Easy assembly for all cable types with the preadjusted one step
FC stripping tool • The prepared cable is connected in the FastConnect
• Reliable shield contacting and strain relief products using the insulation displacement method.
■ Integration
Active distributor, Terminal device,
e.g. SCALANCE X-400 e.g. S7-300
A Installation cable, B
e.g. FC TP standard cable 4 x 2
Connection C Connection
socket, socket,
G_IK10_XX_10061
IE FC RJ45 IE FC RJ45
Modular Outlet Modular Outlet
A+B ≤ 10 m
A+B+C ≤ 100 m
PROFINET/Industrial Ethernet
Cabling technology
Industrial Ethernet FastConnect
■ Overview ■ Benefits
1)
Available as a download under www.profinet.com
PROFINET/Industrial Ethernet
Cabling technology
Industrial Ethernet FastConnect
■ Application
Industrial Ethernet FastConnect is a quick-assembly system After stripping, the IE FC cable can be directly mounted in
for easy assembly of 4-core and 8-core Industrial Ethernet FC the IE FC RJ45 Plug (4-core), the IE M12 Plug PRO 2x2 or 4x2,
cables. the IE FC Outlet RJ45 (4-core), or the IE RJ45 Modular Outlet
(8-core).
2
1 2 3 4
5 6 7
G_IK10_XX_10021
Steps for assembly of Industrial Ethernet copper cables with Industrial Ethernet FastConnect
■ Design ■ Function
The complete system: The FastConnect stripping technique supports fast and easy
• Industrial Ethernet FC installation cables designed for fast connection of the Industrial Ethernet FC cables
assembly; 4-core (2x2) Cat5e; • IE FC RJ45 Plug (10/100/1 000 Mbit/s)
- IE FC TP standard cable GP • IE FC M12 Plug PRO (10/100/1 000 Mbit/s)
- IE FC TP flexible cable GP
- IE FC TP trailing cable GP • IE FC Outlet RJ45 (10/100 Mbit/s)
- IE FC TP Trailing Cable • IE FC RJ45 Modular Outlet (10/100/1 000 Mbit/s)
- IE TP Torsion Cable
- IE FC TP Marine Cable The data terminals and network components are connected
- IE FC TP FRNC cable GP using outlets via TP Cords.
- IE FC TP Food Cable The Industrial Ethernet FastConnect cables are specially de-
- IE FC TP festoon cable GP signed for use of the Industrial Ethernet FastConnect Stripping
- IE TP Ground Cable Tool, with which the outer insulation and the braided shield can
- IE TP Train Cable be stripped accurately in one step. The prepared cable is then
• 8-core (4 x 2) Cat6 certified, with appropriate UL approval: connected using insulation displacement.
- IE FC TP Standard Cable GP (AWG 22/AWG 24) Approvals
- IE FC TP Flexible Cable (AWG 24)
- IE TP Train Cable (AWG 24) UL listing (safety standard) for network cables is especially
• User-friendly stripping technique with FC Stripping Tool necessary for the American and Canadian markets. The require-
ments for the appropriate approvals depend on where the cable
• Noise-resistant FC RJ45 and FC M12 Plugs (10/100/ is routed within the building. This applies to all cables which
1000 Mbit/s), an ideal solution for installation on 4 or 8-core have to be routed from a machine to a remote control cabinet
IE FC cables at the field level thanks to the rugged metal and are positioned on cable racks secured on the building.
enclosure OFN/OFNG cable for routing in bundles (general purpose
• The prepared cable is connected in the Industrial Ethernet cable).
FC Outlet RJ45 (10/100 Mbit/s; 4-core) or IE FC RJ45 Modular
Outlet (10/100/1 000 Mbit/s; 8-core) using insulation The various connectors and cables from the FastConnect ca-
displacement bling system can also be used in hazardous areas (EX-Zone 2).
No special approval is necessary.
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 2 x 2
■ Overview ■ Benefits
IE FC RJ45 IE FC RJ45
Terminal device, Plug 2x2 Plug 2x2 Terminal device,
e.g. S7-1500 e.g. S7-1500
IE FC Cable 2x2
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 2 x 2
■ Design
Industrial Ethernet FC RJ45 Plugs are available in three designs:
• With 180° (straight) • With 145° (angled) • With 90° (angled)
cable outlet cable outlet cable outlet
(SIMOTION and
SINAMICS, for example)
(for ET 200S, for example)
2
They are used for optimized connection of Industrial Ethernet After the stripped cable end has been inserted into the insulation
FastConnect cables to data terminals and network components. displacement terminations (which have been hinged open),
The plugs have a rugged, industry-compatible metal housing the latter are pressed down for reliable contacting of the con-
that provides optimum protection against faults in data commu- ductors.
nication.
Thanks to their compactness, the plug-in connectors
The 4 integrated insulation displacement contacts make con- (IE FC Plug 180°) can be used on devices with individual
tacting of the FC cable variants easy and error-free. sockets and on devices with multiple sockets (blocks).
1 2 3
Strip the IE FC cable 2x2 using stripping Open casing of the FC RJ45 plug Press down contact cover to
tool and fan out the wires according to and insert wires according to color make contact with the wires.
color coding on the contact cover coding as far as the end stop.
of the FC RJ45 plug.
4 5
Casing
G_IK10_XX_30026
■ Function
The IE FC RJ45 Plugs are used to install uncrossed 100 Mbit/s When the housing is open, color markings on the contact cover
Ethernet connections up to 100 m without the use of patches. make it easier to connect the cores to the blade terminals. The
Crossed cables can also be installed by swapping the transmit user can check that contact has been made correctly through
and receive pair in a plug. the transparent plastic material of the contact cover.
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 2 x 2
■ Technical specifications
Article No. 6GK1901-1BB20-2AA0 6GK1901-1BB10-2AA0 6GK1901-1BB30-0AA0
Product-type designation IE FC RJ45 Plug 90 (2x2) IE FC RJ45 Plug 180 (2x2) IE FC RJ45 Plug 145 (2x2)
Product description RJ45 data plug-in connector RJ45 data plug-in connector RJ45 data plug-in connector
2 Acceptability for application For connection to IE FC TP cables 2x2, For connection to IE FC TP cables 2x2, For connection to IE FC TP cables 2x2,
suitable for fast assembly with the suitable for fast assembly with the suitable for fast assembly with the
FastConnect system FastConnect system FastConnect system
Transmission rate
Transfer rate
• 1 for Industrial Ethernet 10 Mbit/s 10 Mbit/s 10 Mbit/s
• 2 for Industrial Ethernet 100 Mbit/s 100 Mbit/s 100 Mbit/s
• 3 for Industrial Ethernet - - -
Interfaces
Number of electrical connections for 4 4 4
Industrial Ethernet FC TP cables
Design of the electrical connection
• for Industrial Ethernet FC TP cables integrated cut-and-clamp contacts integrated cut-and-clamp contacts integrated cut-and-clamp contacts
for 4-wire TP FC installation cable for 4-wire TP FC installation cable for 4-wire TP FC installation cable
• for network components RJ45 connector RJ45 connector RJ45 connector
and terminal equipment
• FastConnect Yes Yes Yes
Mechanical data
Material of the enclosure metal metal metal
Design, dimensions and weight
Type of cable outlet 90 degree cable outlet 180 degree cable outlet 145 degree cable outlet
Width 13.7 mm 13.7 mm 13.9 mm
Height 16 mm 16 mm 16 mm
Depth 42 mm 55 mm 55.6 mm
Net weight 35 g 35 g 35 g
Permitted ambient conditions
Ambient temperature
• during operating -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating maxi-
mum
Protection class IP IP20 IP20 IP20
Chemical resistance to water - - -
Product properties, functions,
components general
Product feature silicon-free Yes Yes Yes
Product component strain relief Yes Yes Yes
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes Yes
• UL-registration Yes Yes Yes
Standard for structured cabling Cat5 Cat5 Cat5
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 2 x 2
2
housing and integrated insulation cable for connection to
displacement contacts for IE FC Outlet RJ45/ IE FC RJ45 Plug
connecting Industrial Ethernet FC for use in trailing cables;
installation cables PROFINET-compatible;
with UL approval;
IE FC RJ45 Plug 180 sold by the meter;
180° cable outlet; max. length 1 000 m,
for network components and minimum order 20 m
CPs/CPUs with Industrial Ethernet IE FC TP Trailing Cable 2 x 2 6XV1840-3AH10
interface (Type C)
• 1 pack = 1 unit 6GK1901-1BB10-2AA0
• 1 pack = 10 units 6GK1901-1BB10-2AB0 4-core, shielded TP installation
cable for connection to
• 1 pack = 50 units 6GK1901-1BB10-2AE0 IE FC Outlet RJ45/ IE FC RJ45 Plug
IE FC RJ45 Plug 90 180/90 for use in trailing cables;
PROFINET-compatible;
90° cable outlet; e.g. for ET 200S without UL approval;
• 1 pack = 1 unit 6GK1901-1BB20-2AA0 sold by the meter;
• 1 pack = 10 units 6GK1901-1BB20-2AB0 max. length 1 000 m,
minimum order 20 m
• 1 pack = 50 units 6GK1901-1BB20-2AE0
IE TP Torsion Cable GP 2 x 2 6XV1870-2F
IE FC RJ45 Plug 145 (Type C)
145° cable outlet; 4-core, shielded TP installation
e.g. for SIMOTION and SINAMICS cable for connection to
• 1 pack = 1 unit 6GK1901-1BB30-0AA0 IE FC Outlet RJ45/ IE FC RJ45 Plug
• 1 pack = 10 units 6GK1901-1BB30-0AB0 for use with robots;
• 1 pack = 50 units 6GK1901-1BB30-0AE0 PROFINET-compatible;
with UL approval;
IE FC stripping tool 6GK1901-1GA00 sold by the meter;
Preadjusted stripping tool for max. length 1 000 m,
fast stripping of Industrial Ethernet minimum order 20 m
FC cables IE FC TP Marine Cable 2 x 2 6XV1840-4AH10
IE FC TP Standard Cable GP 2 x 2 (Type B)
(Type A) 4-core, shielded TP installation
4-core, shielded TP installation cable for connection to
cable for connection to IE FC Outlet RJ45/ IE FC RJ45
IE FC Outlet RJ45/ IE FC RJ45 Plug; Plug 180/90;
PROFINET-compatible; marine approval;
with UL approval; max. length 1 000 m,
minimum order 20 m
Sold by the meter
IE FC TP FRNC Cable GP 2 x 2 6XV1871-2F
max. length 1 000 m; 6XV1840-2AH10 (Type B)
minimum order 20 m
Preferred length 4-core, shielded, halogen-free TP
installation cable for connection to
• 1 000 m 6XV1840-2AU10 IE FC Outlet RJ45/ IE FC RJ45 Plug
IE FC TP Flexible Cable GP 2 x 2 6XV1870-2B for occasional movement;
(Type B) PROFINET-compatible;
with UL approval;
4-core, shielded TP installation sold by the meter;
cable for connection to max. length 1 000 m,
IE FC Outlet RJ45/ IE FC RJ45 Plug minimum order 20 m
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1 000 m,
minimum order 20 m
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 4 x 2
■ Overview ■ Benefits
■ Application
The compact, rugged design of the connectors makes the
• Implementation of direct device connections of up to 90 m FC RJ45 Plug suitable for use in both industrial environments
with Industrial Ethernet FC installation cable 4 x 2 without and on office equipment.
using patch technology The Industrial Ethernet FastConnect RJ45 Plug 4 x 2
• Easy connection (insulation displacement contacts) for 8-core permits quick and easy installation of the Industrial Ethernet
twisted pair installation cables (10/100/1000 Mbit/s) without FastConnect installation cables 2 x 4 (8-core twisted pair
the need for special tools cables) in the field.
• Error-minimizing connection technique thanks to visible The Industrial Ethernet FastConnect Stripping Tool for preparing
connection area as well as colored insulation displacement the end of a cable (stripping the jacket and shield in one step)
termination allows simple handling and fast, reliable fitting of the cable
• Industry-compatible design (rugged metal housing, no easily connector to the cable. As all the cable connector parts are
lost small parts) captive, it can also be fitted in difficult conditions.
• Excellent EMC shielding and deflection (metal housing) The new plug-in connector enables point-to-point links to be
• Integrated strain-relief for installation cables implemented (10/100/1000 Mbit/s) for Industrial Ethernet
between two data terminals/network components up to 90 m
• Compatible with the EN 50173 (RJ45) / ISO IEC 11801 apart without the need for patches.
standard
• Additional strain and bending relief of plug connector possible
through latching of plug on device housing, e.g. with
SCALANCE X, SCALANCE S.
IE FC RJ45 IE FC RJ45
Terminal device, Plug 4x2 Plug 4x2 Terminal device,
e.g. S7-1500 e.g. S7-1500
IE FC TP Cable 4x2
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 4 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Plug 4 x 2
2
with a rugged metal housing and with UL approval;
integrated insulation displacement sold by the meter;
contacts for connecting Industrial max. length 1 000 m,
Ethernet FC installation cables; minimum order 20 m
180° cable outlet; • AWG 24, 6XV1878-2A
for network components and for connection to
CPs/CPUs with Industrial Ethernet IE FC RJ45 Plug 4 x 2
interface
• 1 pack = 1 unit 6GK1901-1BB11-2AA0 IE FC TP Flexible Cable GP 4 x 2
• 1 pack = 10 units 6GK1901-1BB11-2AB0 8-core, shielded TP installation
• 1 pack = 50 units 6GK1901-1BB11-2AE0 cable for occasional movement;
with UL approval;
IE FC stripping tool 6GK1901-1GA00 sold by the meter;
Preadjusted stripping tool max. quantity 1 000 m,
for fast stripping of Industrial minimum order 20 m
Ethernet FC cables • AWG 24, 6XV1878-2B
for connection to
IE FC RJ45 Plug 4 x 2
IE FC blade cassettes (5 mm) 6GK1901-1GB01
Replacement blade cassette for the
Industrial Ethernet stripping tool;
for use with IE FC RJ45 Plugs
and Modular Outlet,
5 units
PROFINET/Industrial Ethernet
Cabling technology
IE Push Pull Plug PRO
■ Overview ■ Benefits
■ Application
IE FC RJ45 Plug PRO and IE SC RJ Plug PRO (POF or PCF) are
plug-in connectors with push pull device connection that thanks
to their high degree of protection (IP65/67) are used outside
cabinets along with suitable end devices and network compo-
nents with a high degree of protection. Their silicon-free design
enables them to also be used in the automobile industry, e.g. in
paint shops.
PROFINET/Industrial Ethernet
Cabling technology
IE Push Pull Plug PRO
■ Technical specifications
Article No. 6GK1901-1BB20-6AA0 6GK1901-1BB10-6AA0
Product-type designation IE FC RJ45 Plug PRO (Push Pull) IE RJ45 Plug PRO (Push Pull)
Product description RJ45 data plug-in connector RJ45 data plug-in connector
Acceptability for application Field-assembly connector for push-pull device connection Field-assembly connector for push-pull device connection
in high degree of protection in high degree of protection
2
Transmission rate
Transfer rate
• 1 for Industrial Ethernet 10 Mbit/s 10 Mbit/s
• 2 for Industrial Ethernet 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical connections
• for Industrial Ethernet FC TP cables 4 4
• for network components 1 1
and terminal equipment
Design of electrical connection
• for Industrial Ethernet FC TP cables integrated cut-and-clamp contacts integrated cut-and-clamp contacts
for 4-wire TP FC installation cable for 4-wire TP FC installation cable
• for network components RJ45 connector (Push Pull device connection) RJ45 connector (Push Pull device connection)
and terminal equipment
Number of optical interfaces - -
for optical waveguide
Design of optical connections - -
for network components or terminal
devices
Design of the electrical connection Yes No
FastConnect
Mechanical data
Material of the enclosure plastic plastic
Design, dimensions and weight
Type of cable outlet 180 degree cable outlet 180 degree cable outlet
Width 22 mm 22 mm
Height 29 mm 30 mm
Depth 73 mm 67.7 mm
Net weight 68.8 g 68.8 g
Permitted ambient conditions
Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C
• during storage -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without - -
condensation during operating
maximum
Protection class IP IP65/67 IP65/67
Chemical resistance to water resistant resistant
Product properties, functions,
components general
Product feature silicon-free Yes Yes
Product component strain relief Yes Yes
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes
• UL-registration Yes Yes
PROFINET/Industrial Ethernet
Cabling technology
IE Push Pull Plug PRO
PROFINET/Industrial Ethernet
Cabling technology
IE Push Pull Plug PRO
2
degree of protection IP65/67; cable for connection to
plastic enclosure, insulation IE FC Outlet RJ45/ IE FC RJ45 Plug
displacement technology, for use as trailing cable;
for SCALANCE X-200IRT PRO and PROFINET-compatible;
SIMATIC ET 200pro switches; with UL approval;
1 package = 1 unit sold by the meter;
max. length 1 000 m,
IE RJ45 Plug PRO 6GK1901-1BB10-6AA0 minimum order 20 m
RJ45 plug-in connector suitable for IE FC TP Trailing Cable 2 x 2 6XV1840-3AH10
on-site assembly in degree of (Type C)
protection IP65/67;
plastic enclosure, insulation 4-core, shielded TP installation
displacement technology, cable for connection to IE
for SCALANCE X-200IRT PRO and FC Outlet RJ45/ IE FC RJ45 Plug
SIMATIC ET 200pro switches; 180/90 for use as trailing cable;
1 package = 1 unit PROFINET-compatible;
with UL approval;
IE SC RJ POF Plug PRO 6GK1900-0MB00-6AA0 sold by the meter;
SC RJ plug-in connector suitable max. length 1 000 m,
for on-site assembly in degree of minimum order 20 m
protection IP65/67 for POF fiber IE TP Torsion Cable 2 x 2 6XV1870-2F
optic cables; (Type C)
plastic housing,
for SCALANCE X-200IRT PRO and 4-core, shielded TP installation
SIMATIC ET 200pro switches; cable for connection to
1 package = 1 unit IE FC Outlet RJ45/ IE FC RJ45 Plug
for use with robots;
IE SC RJ POF Plug PRO 6GK1900-0NB00-6AA0 PROFINET-compatible;
SC RJ plug-in connector suitable with UL approval;
for on-site assembly in degree of sold by the meter;
protection IP65/67 for PCF fiber max. length 1 000 m,
optic cables; minimum order 20 m
plastic housing, IE FC TP Marine Cable 2 x 2 6XV1840-4AH10
for SCALANCE X-200IRT PRO (Type B)
switches;
1 package = 1 unit 4-core, shielded TP installation
cable for connection to
Power Plug PRO 6GK1907-0AB10-6AA0 IE FC Outlet RJ45/ IE FC RJ45
5-pole power plug-in connector Plug 180/90;
suitable for on-site assembly marine approval;
in degree of protection IP65/67 max. length 1 000 m,
for 2 x 24 V voltage supply; minimum order 20 m
plastic housing, IE FC TP Food Cable GP 2 x 2 6XV1871-2L
for SCALANCE X-200IRT PRO and (Type C)
SIMATIC ET 200pro switches;
1 package = 1 unit 4-core, shielded TP installation
cable for connection to
IE FC TP cables IE FC Outlet RJ45/ IE FC RJ45 Plug
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10 180/90 for the food and beverages
(Type A) industry; PROFINET-compatible;
sold by the meter;
4-core, shielded TP installation max. length 1 000 m,
cable for connection to IE minimum order 20 m
FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible; IE FC TP Festoon Cable GP 2 x 2 6XV1871-2S
with UL approval; (Type B)
sold by the meter; 4-core, shielded TP installation
max. length 1 000 m, cable for connection to
minimum order 20 m IE FC Outlet RJ45/ IE FC RJ45
IE FC TP Flexible Cable GP 2 x 2 6XV1870-2B Plug 180/90 for use in festoon
(Type B) applications; PROFINET-compatible;
with UL approval;
4-core, shielded TP installation sold by the meter;
cable for connection to max. length 1 000 m,
IE FC Outlet RJ45/ IE FC RJ45 Plug minimum order 20 m
for occasional movement;
PROFINET-compatible; IE FC TP FRNC Cable GP 2 x 2 6XV1871-2F
with UL approval; (Type B)
sold by the meter; 4-core, shielded, halogen-free TP
max. length 1 000 m, installation cable for connection to
minimum order 20 m IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1 000 m,
minimum order 20 m
PROFINET/Industrial Ethernet
Cabling technology
IE Push Pull Plug PRO
■ More information
Note:
Supplementary components for the SIMATIC NET cable range
can be ordered from your local contact person.
Technical advice on this subject is available from:
J. Hertlein
I IA SC CI PRM 4
Phone: +49 (911) 750-4465
E-mail: juergen.hertlein@siemens.com
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
■ Overview
Industrial Ethernet FC M12 Plug PRO (D coded)
• Industrial Ethernet M12 plug-in connector with FastConnect
connection system for on-site assembly for
2
SCALANCE X208PRO, IM 154-4 PN and SIMATIC RF systems
• Easy connection (insulation displacement contacts) for
4-core twisted pair FC installation cables (10/100 Mbit/s)
without the need for special tools
• Fault-preventing connection method thanks to visible
contacting area and color-coded insulation piercing
connecting devices
• Industry-compatible design (rugged metal enclosure)
• Excellent EMC shielding and deflection (metal enclosure)
• Integrated strain-relief for installation cables
Industrial Ethernet FC M12 Plug PRO 4 x 2 (X-coded)
• Industrial Ethernet M12 plug connectors, which can be
assembled in the field, for on-site installation for
SCALANCE W
FastConnect (FC) plug-in connectors that can be assembled in • Easy connection (insulation displacement contacts) for 8-core
the field for transmission of data (up to 1000 Mbit/s) between twisted pair FC installation cables (10/100/1000 Mbit/s)
Industrial Ethernet nodes with IP65/IP67 degree of protection without the need for special tools
• Fault-preventing connection method thanks to visible
contacting area and color-coded insulation piercing
connecting devices
• Industry-compatible design (rugged metal enclosure)
• Excellent EMC shielding and deflection (metal enclosure)
• Integrated strain-relief for installation cables
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
■ Technical specifications
Article No. 6GK1901-0DB20-6AA0 6GK1901-0DB30-6AA0
Product-type designation IE FC M12 Plug PRO (PROFINET) IE FC M12 Plug PRO (PROFINET)
Product description M12 plug-in connector, high degree of protection, 4-pole, M12 plug-in connector, high degree of protection, 8-pole,
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
2 Acceptability for application Panel feedthrough for conversion from M12 connection
method (D-coded, IP65/IP67) to RJ45 connection method
M12/M12 coupler and panel feedthrough (D-coded)
(IP20)
Transmission rate
Transfer rate
• 1 for Industrial Ethernet 10 Mbit/s 10 Mbit/s
• 2 for Industrial Ethernet 100 Mbit/s 100 Mbit/s
• 3 for Industrial Ethernet - -
Interfaces
Number of electrical connections for - -
Industrial Ethernet FC TP cables
Design of electrical connection
• for Industrial Ethernet FC TP cables - -
• for network components and M12 socket (D-coded) and RJ45 2 x M12 socket (D-coded)
terminal equipment
• FastConnect No No
Mechanical data
Material of the enclosure plastic metal
Design, dimensions and weight
Type of cable outlet 90 degree cable outlet 180 degree cable outlet
Width 24 mm 35.6 mm
Height 45 mm 22.6 mm
Depth 35.4 mm 44.5 mm
Net weight 0.04 kg 0.036 kg
Permitted ambient conditions
Ambient temperature
• during operating 0 … 70 °C -5 … +60 °C
• during storage 0 … 70 °C -5 … +60 °C
• during transport 0 … 70 °C -5 … +60 °C
Relative humidity at 25 °C without - -
condensation during operating
maximum
Protection class IP IP65/67 (M12) / IP20 (RJ45) IP65/67 (M12) / IP65/67 (M12)
Chemical resistance to water - resistant
Product properties, functions,
components general
Product feature silicon-free Yes Yes
Product component strain relief Yes Yes
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes
• UL-registration Yes No
Standard for structured cabling Cat5 Cat5
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
2
assembled in the field, cable for connection to IE FC Outlet
metal enclosure, RJ45/ IE FC RJ45 Plug
FastConnect connection method, for use with robots;
for SCALANCE X208PRO and PROFINET-compatible;
IM 154-4 PN with UL approval;
• 1 unit 6GK1901-0DB20-6AA0 sold by the meter;
• 8 unit 6GK1901-0DB20-6AA8 max. length 1 000 m,
minimum order length 20 m
IE FC M12 Plug PRO 4 x 2
IE FC TP Marine Cable 2 x 2 6XV1840-4AH10
M12 plug-in connector suitable (Type B)
for on-site assembly (X-coded,
IP65/IP67), metal enclosure, 4-core, shielded TP installation
insulation/displacement fast cable for connection to
connection method, IE FC Outlet RJ45/ IE FC RJ45
for SCALANCE W Plug 180/90;
marine approval;
• 1 unit 6GK1901-0DB30-6AA0 max. length 1 000 m,
• 8 units 6GK1901-0DB30-6AA8 minimum order 20 m
IE panel feedthrough IE FC TP Trailing Cable GP 2 x 2 6XV1870-2D
(Type C)
Control cabinet feedthrough for
conversion from M12 connection 4-core, shielded TP installation
method (D coded, IP65/IP67) to cable for connection to
RJ45 connection method (IP20) IE FC Outlet RJ45/ IE FC RJ45 Plug
• 1 pack = 5 units 6GK1901-0DM20-2AA5 for use as trailing cable;
PROFINET-compatible;
IE panel feedthrough PRO with UL approval;
Coupling of M12 plug-in connectors sold by the meter;
(D-coded, IP65/IP67); max. length 1 000 m,
can be used as cabinet bushing or minimum order 20 m
for connecting two M12 plug-in IE FC TP Festoon Cable GP 2 x 2 6XV1871-2S
connectors outside the control (Type B)
cabinet
• 1 pack = 5 units 6GK1901-0DM30-2AA5 4-core, shielded TP installation
cable for connection to
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10 IE FC Outlet RJ45/ IE FC RJ45
(Type A) Plug 180/90 for use in festoon
applications;
4-core, shielded TP installation PROFINET-compatible;
cable for connection to with UL approval;
IE FC Outlet RJ45/ IE FC RJ45 Plug; sold by the meter;
PROFINET-compatible; max. length 1 000 m,
with UL approval; minimum order 20 m
sold by the meter;
max. length 1 000 m, IE FC TP Food Cable GP 2 x 2 6XV1871-2L
minimum order 20 m (Type C)
Preferred length 4-core, shielded TP installation
• 1 000 m 6XV1840-2AU10 cable for connection to
IE FC Outlet RJ45/IE FC RJ45
IE FC TP Flexible Cable GP 2 x 2 6XV1870-2B Plug 180/90 for the food and
(Type B) beverages industry;
4-core, shielded TP installation PROFINET-compatible;
cable for connection to sold by the meter;
IE FC Outlet RJ45/ IE FC RJ45 Plug max. length 1 000 m,
for occasional movement; minimum order 20 m
PROFINET-compatible; IE FC TP FRNC cable GP 2x2 6XV1871-2F
with UL approval; (Type B)
sold by the meter;
max. length 1 000 m, 4-core, shielded, halogen-free TP
minimum order 20 m installation cable for connection to
IE FC Outlet RJ45/IE FC RJ45 Plug
IE FC TP Trailing Cable 2 x 2 6XV1840-3AH10 for occasional movement;
(Type C) PROFINET-compatible;
4-core, shielded TP installation with UL approval;
cable for connection to IE FC Outlet sold by the meter;
RJ45/ IE FC RJ45 Plug 180/90 max. length 1 000 m,
for use in trailing cables; minimum order 20 m
PROFINET-compatible;
without UL approval;
sold by the meter;
max. length 1 000 m,
minimum order 20 m
PROFINET/Industrial Ethernet
Cabling technology
IE FC M12 Plug PRO
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
■ Overview ■ Application
For the construction of Industrial Ethernet networks (4-core),
different cable types are offered to suit the different types of
application.
In general, the listed Industrial Ethernet FC cables IE FC Cable
2 x 2 must be used. 2
Note:
You will find other specifications of the network topology in the
manual for TP and fiber optic networks and in the Industrial
Ethernet/PROFINET system manual.
UL approvals
Different cable variants are offered with appropriate UL/ETL
approvals for laying in cable bundles and cable racks according
to the specifications of NEC (National Electrical Code)
Article 800/725. These are identified as GP (General Purpose).
■ Design
• 4-core FastConnect installation cables for structured Fast
Ethernet cabling with special design for fast installation
• Easy stripping with the FastConnect Stripping Tool; the outer
sheath and the braided shield are stripped accurately in one
step
• Connection to FastConnect products using insulation outer sheath
displacement foil shield
G_IK10_XX_10033
(e.g. trailing, food, marine, railways)
• High interference immunity thanks to double shielding braided shield
• Easy length measurement thanks to printed meter markings single core sheath
■ Benefits
The FastConnect (FC) Industrial Ethernet cables IE FC Cable
2 x 2 are designed with radial symmetry and therefore allow the
use of the FC Stripping Tool The IE FC Outlet RJ45 and the
IE FC Plugs can therefore be attached quickly and easily.
• Time-saving due to simple and quick assembly with • The double shield makes it especially suitable for routing
FastConnect cables 2 x 2 to Industrial Ethernet FC Outlet RJ45 through industrial areas with strong electro-magnetic fields
(10/100 Mbit/s), Industrial Ethernet FC RJ45 Plug 180/145/90, • Easy connection to the insulation displacement contacts of the
or IE FC M12 Plug PRO 2x2 IE FC plug without the need for special tools
• Versatile application due to special bus cables • System-wide grounding concept can be implemented through
• Network is immune to interference thanks to double shielded the outer shield of the bus cable as well as through the
cables and a uniform grounding concept grounding concept of the IE FC Outlet RJ45 and the IE FC
Plugs
• Silicone-free, therefore suitable for use in the automotive
industry (for example on paint lines) • Printed meter marks
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
■ Design (continued)
Cable types Product overview IE FC TP Cable 2 x 2
• IE FC TP Standard Cable GP 2 x 2: (PROFINET-compatible according to "PROFINET Cabling
Standard bus cable with rigid cores specially designed for fast and Interconnection Technology Guideline"1))
installation;
2 four rigid cores connected in a four branch star
PROFINET
Type A
PROFINET
Type B
PROFINET
Type C
• IE FC TP Robust Standard Cable GP 2x2: AWG 22/1 AWG 22/7 AWG 22
Standard bus cable with rigid cores specially designed for fast rigid laying flexible cable highly flexible
installation; for occa- cable for contin-
four rigid cores connected in a four branch star with a rugged sional move- uous motion, e.g.
TPE outer sheath (thermoplastic elastomer) ment cable carrier or
robots
• IE FC TP Flexible Cable GP 2 x 2:
IE FC TP ! – –
Flexible bus cable for the special application of occasional Standard Cable GP
motion control; 2x2
four stranded cores connected in a four branch star (Type A)
6XV1 840-2AH10
• IE FC TP Robust Flexible Cable GP 2x2:
Flexible bus cable for the special application of occasional IE FC TP ! – –
motion control; Robust Standard
Cable GP
four rigid cores connected in a four branch star with a rugged 2x2
TPE outer sheath (thermoplastic elastomer) (Type A)
• IE FC TP FRNC Cable GP 2 x 2: 6XV1841-2A
Flexible, halogen-free cable for use in buildings (FRNC= IE FC TP – ! –
Flame Retardant Non Corrosive); four conductors (flexible Flexible Cable GP
leads) stranded into star-quad for occasional movement 2x2
(Type B)
• IE FC TP Trailing Cable GP / IE FC TP Trailing Cable 2 x 2: 6XV1 870-2B
Highly flexible bus cable for the special application of IE FC TP – ! –
constant motion control in a cable carrier, e.g. for continuously Robust Flexible Cable GP
moving machine parts; four stranded cores connected in a 2x2
four branch star (Type B)
6XV1841-2B
• IE FC Festoon Cable GP 2 x 2:
Flexible cable for special use in constant movement in a cable IE FC TP – ! –
FRNC Cable GP
trail/festoon arrangement, e.g. on crane systems; four cores 2x2
(stranded) in twisted quads (Type B)
• IE TP Torsion Cable 2 x 2: 6XV1 871-2F)
Highly flexible bus cable for the special application of IE FC TP – – !
continuous motion control, e.g. for use with robots; stranded Trailing Cable GP
cores 2x2
(Type C)
• IE FC TP Food Cable 2 x 2: 6XV1 870-2D
Flexible cable for special use in the food and beverages IE FC TP – – !
industry; Trailing Cable
four cores (stranded) in twisted quads 2x2
(Type C)
• IE FC TP Marine Cable 2 x 2: 6XV1 840-3AH10
Bus cable for marine applications; four cores (stranded)
connected in a four branch star, halogen-free, certified for IE FC TP – ! –
Festoon Cable GP
marine applications 2x2
• IE TP Ground Cable 2 x 2: (Type B)
Bus cable for fixed routing in soil; four rigid cores connected 6XV1871-2S
in a four branch star, additional outer PE sheath (internal FC IE TP Torsion Cable – – !
cable design) 2x2
(Type C)
• IE TP Train Cable 2 x 2: 6XV1 870-2F
Bus cable for special applications in trains; four cores
(tin-coated stranded wires) connected in a four branch star, IE FC TP Food Cable – – !
2x2
certified for railway applications (Type C)
6XV1871-2L
IE FC TP Marine Cable – ! –
2x2
(Type B)
6XV1 840-4AH10
IE TP Ground Cable – – !
2x2
(Type C)
6XV1871-2G
IE TP Train Cable – – !
2x2
(Type C)
6XV1871-2T
1)
Available as a download under
http://www.profinet.com
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
■ Technical specifications
Article No. 6XV1840-2AH10 6XV1841-2A 6XV1870-2B 6XV1841-2B
Product-type designation IE FC TP Standard Cable IE FC TP Robust Standard IE FC TP Flexible Cable GP IE FC TP Robust Flexible
GP 2 x 2 (Type A) Cable GP 2 x 2 (Type A) 2 x 2 (Type B) Cable GP 2 x 2 (Type B)
Product description Standard bus cable (4-core), Standard bus cable (4-core), Flexible bus cable (4-core),
sold by the meter, sold by the meter, sold by the meter,
Flexible bus cable (4-core),
sold by the meter, 2
not assembled not assembled not assembled not assembled
Acceptability for application Standard cable with rigid Standard cable with rigid For occasionally moved For occasionally moved
cores for fast installation cores for fast installation machine parts machine parts
Cable designation 2YY (ST) CY 2x2x0,64/1,5- 2YH (ST) C99Y 2x2x0,64/1,5- 2YY (ST) CY 2x2x0,75/1,5- 2YH (ST) C99Y 2x2x0,75/1,5-
100 GN 100 GN 100 LI GN 100 LI GN
Electrical data
Damping ratio per length
• at 10 MHz 52 dB/km 52 dB/km 60 dB/km 60 dB/km
• at 100 MHz 195 dB/km 195 dB/km 210 dB/km 210 dB/km
Impedance for frequency range 100 100 100 100
1 MHz … 100 MHz
Relative symmetrical tolerance 15 % 15 % 15 % 15 %
of the surge impedance
at 1 MHz … 100 MHz
Near-end crosstalk per length 500 dB/km 0.5 dB/m 500 dB/km 0.5 dB/m
at 1 MHz ... 100 MHz
Transfer impedance at 10 MHz 10 m/m 10 m/m 20 m/m 20 m/m
Loop resistance per length 115 /km 115 /km 120 /km 120 /km
Insulation resistance coefficient - - - -
Operating voltage RMS value 100 V 100 V 100 V 100 V
Percentage NVP value 66 % 66 % 66 % 66 %
Mechanical data
Number of electrical wires 4 4 4 4
Design of shield Overlapped aluminum-clad Overlapped aluminum-clad Overlapped aluminum-clad Overlapped aluminum-clad
foil, sheathed in a braided foil, sheathed in a braided foil, sheathed in a braided foil, sheathed in a braided
screen of tin-plated copper screen of tin-plated copper screen of tin-plated copper screen of tin-plated copper
wires wires wires wires
Design of the electrical connection Yes Yes Yes Yes
FastConnect
AWG number - - - -
Core diameter of the AWG22 core 0.64 mm 0.64 mm 0.75 mm 0.75 mm
Outer diameter
• of the inner conductor 0.64 mm 0.64 mm 0.75 mm 0.75 mm
• of the wire insulation 1.5 mm 1.5 mm 1.5 mm 1.5 mm
• of the inner sheath of the cable 3.9 mm 3.9 mm 3.9 mm 3.9 mm
• of the cable sheath 6.5 mm 6.5 mm 6.5 mm 6.5 mm
Symmetrical tolerance 0.2 mm 0.2 mm 0.2 mm 0.2 mm
of outer diameter of cable sheath
Material
• of the wire insulation PE PE PE PE
• of the inner sheath of the cable PVC FRNC PVC FRNC
• of the cable sheath PVC TPE (FR-TPE) PVC TPE (FR-TPE)
Color
• of the insulation of data wires white / yellow / blue / orange white / yellow / blue / orange white / yellow / blue / orange white / yellow / blue / orange
• of the cable sheath green green green green
Bending radius
• with single bend 19.5 mm 19.5 mm 32.5 mm 32.5 mm
• with multiple bends 49 mm 49 mm 52 mm 52 mm
• with continuous bending - - - -
Number of bending cycles - - - -
• Note - - - -
Number of torsion cycles with torsion - - - -
by ± 180° on 1 m cable length
Traction stress maximum 150 N 150 N 150 N 150 N
Weight per length 67 kg/km 67 kg/km 68 kg/km 68 kg/km
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
2 Ambient temperature
• during operating -40 … +70 °C -40 … +80 °C
• during storage -40 … +70 °C -40 … +80 °C
• during transport -40 … +70 °C -40 … +80 °C
• during installation -5 … +50 °C -20 … +60 °C
Ambient condition for (standard) - Electrical characteristics measured at 20 ºC,
operation mode tests according to EN 50288-2-1
Burning behaviour inflammable BS6853, DIN5510-2 levels of protection 1-4,
prEN45545-2 Hazard Level HL1-HL3,
EN50306-4, NF F 16-101, NFPA130
Chemical resistance
• to mineral oil Conditional resistance EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903)
• to grease Conditional resistance Conditional resistance
• to water Resistant Conditional resistance
Radiological resistance Resistant Resistant
to UV radiation
Product properties, functions,
components general
Product feature
• halogen-free No Yes
• silicon-free Yes Yes
Cable length with 100BaseTX for 100 m 100 m
Industrial Ethernet
Standards, specifications,
approvals
UL/ETL listing with 300 V rating No No
UL/ETL style with 600 V rating No No
Verification of suitability
• CE mark Yes Yes
• UL-registration - -
• RoHS conformity Yes Yes
Standard for structured cabling Cat5e Cat5
Marine classification association
• American Bureau No No
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) No No
• Det Norske Veritas (DNV) No No
• Germanische Lloyd (GL) No No
• Lloyds Register of Shipping (LRS) No No
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
2
cable for connection to cable for connection to
IE FC Outlet RJ45/IE FC RJ45/M12 IE FC Outlet RJ45/IE FC RJ45/M12
Plug; PROFINET-compatible; Plug for use in festoon applications;
with UL approval; PROFINET-compatible;
Sold by the meter; 6XV1840-2AH10 with UL approval;
max. length 1 000 m, sold by the meter;
minimum order 20 m max. length 1 000 m,
Preferred length minimum order 20 m
• 1000 m 6XV1840-2AU10 IE TP torsion cable 2 x 2 6XV1870-2F
(Type C)
IE FC TP Robust Cable GP 2 x 2 6XV1841-2A
(Type A) 4-core, shielded TP installation
cable for connection to
4-core, shielded TP installation
IE FC Outlet RJ45/IE FC RJ45/M12
cable with TPE outer sheath for
Plug for use with robots;
connection to IE FC Outlet RJ45/
PROFINET-compatible;
IE FC RJ45/M12 Plug;
with UL approval;
PROFINET-compatible;
sold by the meter;
with UL approval
max. length 1 000 m,
Sold by the meter; minimum order 20 m
max. length 1 000 m,
minimum order 20 m IE FC TP Food Cable GP 2 x 2 6XV1871-2L
(Type C)
IE FC TP Flexible Cable GP 2 x 2 6XV1870-2B
(Type B) 4-core, shielded TP installation
cable for connection to
4-core, shielded TP installation IE FC Outlet RJ45/IE FC RJ45/
cable for connection to M12 Plug for the food and
IE FC Outlet RJ45/IE FC RJ45/M12 beverages industry;
Plug for occasional movement; PROFINET-compatible;
PROFINET-compatible; sold by the meter;
with UL approval; max. length 1 000 m,
Sold by the meter; minimum order 20 m
max. length 1 000 m,
minimum order 20 m IE FC TP Marine Cable 2 x 2 6XV1840-4AH10
(Type B)
IE FC TP Robust Flexible Cable 6XV1841-2B
GP 2 x 2 (Type B) 4-core, shielded TP installation
cable for connection to
4-core, shielded TP installation IE FC Outlet RJ45/IE FC RJ45/M12
cable with TPE outer sheath for con- Plug marine approval;
nection to IE FC Outlet RJ45/ sold by the meter;
IE FC RJ45/M12 Plug for occasional max. length 1 000 m,
movement; PROFINET-compatible; minimum order 20 m
with UL approval;
Sold by the meter; max. length IE TP Ground Cable 2 x 2 6XV1871-2G
1 000 m, minimum order 20 m (Type C)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
■ Overview ■ Application
The 8-core cabling system of SIMATIC NET allows transmission
rates of 10/100/1 000 Mbit/s for Ethernet as with the service-in-
dependent cabling from the office environment. This permits the
transition from the 4-core Industrial Ethernet cabling system to
the 8-core cabling system with Gigabit capability. 2
The IE FC TP Standard Cable GP 4 x 2 (AWG22) must be used
in conjunction with the IE FC Modular Outlet and the TP Cords
for constructing Industrial Ethernet networks (8-core) up to
100 m.
IE FC TP Standard Cable 4x2 (AWG22)
The IE FC TP Standard Cable GP 4 x 2 (AWG22) must be used
in conjunction with the IE FC Modular Outlet and the TP Cords
for constructing Industrial Ethernet networks (8-core) up to
100 m.
IE FC TP Cable 4x2 (AWG24)
For direct connection without using patch technology, the
IE FC RJ45 Plug 4 x 2 and the IE FC TP Cable 4 x 2 (AWG24) of
• 8-core FastConnect installation cables for cabling system with up to 90 m can be used.
Gigabit capability (AWG22 and AWG24 versions)
IE TP Train Cable 4x2 (AWG24)
• Easy stripping with the FastConnect Stripping Tool; the outer
sheath and the braided shield are stripped accurately in one For the construction of Industrial Ethernet networks (8-core) up
step to 100 m in railway applications (cable is approved for railway
• Connection to IE FC RJ45 Modular Outlet (AWG22) or applications)
IE FC RJ45 Plug 4 x 2 (AWG24) using insulation displacement Note:
• Satisfies Category 6 (Cat6) of the international cabling Further information on the network configuration can be found in
standards ISO/IEC 11801 and EN 50173 the manual for TP and fiber-optic networks.
• UL approval UL approvals
• Easy length measurement thanks to printed meter markings
The IE FC TP cable GP 4 x 2 (AWG22 and AWG24) has the rele-
vant UL / ETL approvals for laying in cable bundles and cable
■ Benefits racks according to the specifications of NEC (National Electrical
Code) Article 800/725.
■ Design
• Time-saving due to quick and easy assembly using
FastConnect cables 4 x 2 on IE FC RJ 45 Modular Outlet or
IE FC RJ45 Plug 4 x 2 or IE FC M12 Plug PRO 4x2 (X-coded)
• Simple and error-free construction of an 8-core cabling system foil shield
with Gigabit capability
outer sheath
• Due to the 8-core cabling, you can either implement two
Industrial Ethernet connections for Fast Ethernet (with inner sheath
IE FC RJ 45 Modular Outlet) or one Gigabit Ethernet
Cable 4x2
Standard
• Noise-immune network due to a consistent grounding IE FC TP
concept.
G_IK10_XX_10046
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
G_IK10_XX_10086
Outlet
cable bundles and on cable racks, according to the specifica- Insert 1GE
IE FC Standard Cable 4x2
tions of the NEC (National Electrical Code) Article 800/725
• IE Train Cable GP 4 x 2 (AWG24/7): 1 x 1000 Mbit/s
connection
Bus cable with flexible cores for laying in trains (railway IE TP Cord
applications) with appropriate approval, connection only
possible via IE FC M12 Plug PRO 4x2 (x-coded) System configuration with IE FC RJ45 Modular Outlet 100 Mbit/s
and 1000 Mbit/s
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
■ Technical specifications
Article No. 6XV1870-2E 6XV1878-2A
Product-type designation IE FC TP Standard Cable GP 4x2 (AWG 22) IE FC TP Standard Cable GP 4x2 (AWG 24)
Product description Standard bus cable (8-core), sold by the meter, Shielded TP installation cable (8-core), sold by the meter,
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
2 Ambient temperature
• during operating -40 … +80 °C -40 … +85 °C
• during storage -40 … +80 °C -40 … +85 °C
• during transport -40 … +80 °C -40 … +85 °C
• during installation -40 … +80 °C -40 … +80 °C
Burning behaviour flame resistant according to IEC 60332-1 flame resistant according to IEC 60332-3-24 (Category C)
Chemical resistance
• to mineral oil oil resistant according to IEC 60811-2-1 (4 h / 70°C) oil resistant according to IEC 60811-2-1 (4 h / 70°C)
• to grease Conditional resistance Conditional resistance
• to water Conditional resistance Conditional resistance
Radiological resistance to Resistant Resistant
UV radiation
Product properties, functions,
components general
Product feature
• halogen-free No No
• silicon-free Yes Yes
Cable length
• with 100BaseTX 90 m 100 m
for Industrial Ethernet
• with 1000BaseT 90 m 100 m
for Industrial Ethernet
Standards, specifications,
approvals
UL/ETL listing with 300 V rating Yes: c(UL)us, CMG, Sun Res Yes: c(UL)us, CMG
UL/ETL style with 600 V rating No No
Verification of suitability
• CE mark Yes Yes
• RoHS conformity Yes Yes
Standard for structured cabling Cat6 Cat6
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
2 Ambient temperature
• during operating -40 … +80 °C -40 … +80 °C
• during storage -40 … +80 °C -40 … +80 °C
• during transport -40 … +80 °C -40 … +80 °C
• during installation -40 … +80 °C -20 … +60 °C
Ambient condition for (standard) Temperature range for permanent installation -
operation mode -40 °C to +85 °C
Burning behaviour flame resistant according to IEC 60332-3-24 (Category C) BS 6853, DIN5510-2 levels of protection 1-4, prEN 45545-2
Hazard Level HL 1-HL 3, EN 50306-4, NF F 16-101,
NFPA130
Chemical resistance
• to mineral oil oil resistant according to IEC 60811-2-1 (4 h / 70°C) EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903)
• to grease Conditional resistance Conditional resistance
• to water Conditional resistance Conditional resistance
Radiological resistance to Resistant Resistant
UV radiation
Product properties, functions,
components general
Product feature
• halogen-free No Yes
• silicon-free Yes Yes
Cable length
• with 100BaseTX 80 m 100 m
for Industrial Ethernet
• with 1000BaseT 80 m 100 m
for Industrial Ethernet
Standards, specifications,
approvals
UL/ETL listing with 300 V rating Yes: c(ETL)us, CMG No
UL/ETL style with 600 V rating No No
Verification of suitability
• CE mark Yes Yes
• RoHS conformity Yes Yes
Standard for structured cabling Cat6 Cat7
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
2
with UL approval; a replaceable insert;
sold by the meter; • without replaceable insert 6GK1901-1BE00-0AA0
max. length 1 000 m, • With 2FE insert; 6GK1901-1BE00-0AA1
minimum order 20 m replaceable insert for
• AWG22, 6XV1870-2E 2 x 100 Mbit/s interfaces
for connection • With 1GE insert; 6GK1901-1BE00-0AA2
to IE FC RJ45 Modular Outlet replaceable insert for
• AWG24, 6XV1878-2A 1 x 1 000 Mbit/s interfaces
for connection to • With power insert; 6GK1901-1BE00-0AA3
IE FC RJ45 Plug 4 x 2, replaceable insert for
IE FC M12 Plug PRO 4 x 2 1 x 24 V DC and
IE FC TP Flexible Cable GP 4 x 2 1 x 100 Mbit/s interface
8-core, shielded TP installation IE FC RJ45 Modular Outlet Insert 6GK1901-1BK00-0AA1
cable for occasional movement; 2FE
with UL approval; Replaceable insert for
sold by the meter; FC Modular Outlet Base;
max. length 1 000 m, 2 x RJ45 for
minimum order 20 m 2 x 100 Mbit/s interfaces;
• AWG24, 6XV1878-2B 1 pack = 4 items
for connection to
IE FC RJ45 Plug 4 x 2, IE FC RJ45 Modular Outlet Insert 6GK1901-1BK00-0AA2
IE FC M12 Plug PRO 4 x 2 1GE
IE TP Train Cable GP 4 x 2 Replaceable insert for
FC Modular Outlet Base;
8-core, shielded TP installation 1 x RJ45 for
cable for use in trains; 1 x 1000 Mbit/s interface;
sold by the meter; 1 pack = 4 items
max. length 1 000 m,
minimum order 20 m IE FC RJ45 Plug 4 x 2
• AWG24, 6XV1878-2T RJ45 plug connector for
for connection to Industrial Ethernet with a rugged
IE M12 RJ45 Plug PRO 4 x 2 metal housing and integrated
IE FC stripping tool 6GK1901-1GA00 insulation displacement contacts
for connecting Industrial Ethernet
Preadjusted stripping tool for FC installation cables 4 x 2;
fast stripping of Industrial Ethernet 180° cable outlet;
FC cables 4 x 2 for network components and
CPs/CPUs with Industrial Ethernet
IE FC Blade Cassettes (5 mm) 6GK1901-1GB01 interface
Replacement blade cassette for the • 1 pack = 1 unit 6GK1901-1BB11-2AA0
Industrial Ethernet stripping tool, • 1 pack = 10 units 6GK1901-1BB11-2AB0
for use with IE FC RJ45 Plugs and • 1 pack = 50 units 6GK1901-1BB11-2AE0
IE FC RJ45 Modular Outlet,
5 units IE FC M12 Plug PRO 4 x 2
M12 plug-in connector suitable
for on-site assembly (X-coded,
IP65/IP67), metal enclosure,
insulation/displacement
fast connection method,
for SCALANCE W
• 1 unit 6GK1901-0DB30-6AA0
• 8 units 6GK1901-0DB30-6AA8
SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0
Electronic manuals for
communication systems,
communication protocols,
and communication products;
on DVD;
German/English
■ More information
Installation instructions Cable routing
The bus cable is supplied by the meter with meter marks printed During storage, transport and cable laying, keep both ends
on it. sealed with a shrink-on cap; comply with the permissible
bending radii and tensile load.
FastConnect
With the help of Industrial Ethernet FastConnect Stripping Tool,
it is possible to strip the outer sheath and shield of the Industrial
Ethernet FastConnect cable 4 x 2 to the right length in one step.
This allows the IE FC RJ45 Modular Outlet to be attached quickly
and easily to the Industrial Ethernet FC cable 4 x 2.
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
■ Overview ■ Application
Different cable types are needed to supply power to Industrial
Ethernet/PROFINET or PROFIBUS. The listed power cables
should always be used. They are used for devices with IP65/67
degree of protection to connect the signaling contact or 24-V
2 supply of the SCALANCE X and SCALANCE W components
(power cable 2x0.75) and for the power supply (power cable
5x1.5 for ET 200).
In addition, preassembled power connecting cables (4 x 0.75)
are available in different lengths for the power supply of the
ET 200 (M12 Power Connecting Cable).
UL approvals
As a result of appropriate UL styles, the cables can be used
worldwide.
■ Design
Rugged 2-core, 4-core or 5-core cable with circular cross-
section for connection of signaling contact and power supply to
• Different versions (5-core, 2-core) for different fields of IP65/67 components in industrial areas.
application
Cable types
• Pre-assembled M12 plug-in cables for energy transfer
The following cables with industrial capability are available for
• Rugged cable design for installation in industrial applications connection of the power supply and signaling contact:
• UL approvals • Power cable 2 x 0.75;
• Easy length measurement thanks to printed meter markings power cable for connection of signaling contact and 24 V
supply voltage to SCALANCE X and SCALANCE W compo-
■ Benefits nents
• Power cable 5 x 1.5;
power cable for connection of 24 V power supply of ET 200
using 7/8" plug connectors
• M12 Power Connecting Cable M12-180/M12-180;
• Flexible application possibilities thanks to rugged cable 4-core M12 power connecting cables (A-coded) with straight
design cable outlet for 24 V power supply of the ET 200 (pre-
assembled)
• Silicon-free, therefore particularly suitable for use in the
automotive industry (e.g. on paint shop conveyors)
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
■ Technical specifications
Article No. 6XV1812-8A 6XV1830-8AH10
Product-type designation Energy Cable 2 x 0.75 Energy Cable 5 x 1.5
Product description Energy cable (2-core), sold by the meter, not assembled Energy cable (5-core), sold by the meter, not assembled
Acceptability for application Connection of signaling contact and 24 V power supply to Power supply of ET 200 modules with 7/8" power port
SCALANCE X and SCALANCE W
2
Cable designation L-YY-2x1x0.75 GR L-Y11Y-Z 5x1x1.5 GR
Electrical data
Operating voltage RMS value 600 V 600 V
Conductor cross section 0.75 mm² 1.5 mm²
of the power wires
Continuous current 6A 16 A
of the power wires
Mechanical data
Number of electrical wires 2 5
Design of the electrical connection - No
FastConnect
Outer diameter
• of the inner conductor 1.3 mm 1.55 mm
• of the wire insulation 2.5 mm 2.73 mm
• of the cable sheath 7.4 mm 10.5 mm
Material
• of the wire insulation PVC PVC
• of the cable sheath PVC PUR
Symmetrical tolerance of outer diame- 0.3 mm 0.3 mm
ter of cable sheath
Color
• of the power wire insulation Brown/blue 4x black, 1x green / yellow
• of the cable sheath gray gray
Bending radius
• with single bend 19 mm 27 mm
• with multiple bends 45 mm 63 mm
• with continuous bending - 75 mm
Number of bending cycles - 5 000 000
• Note - For use in cable carriers, for 5 million bending cycles
with a bending radius of 75 mm,
an acceleration of 4 m/s² and a speed of 180 m/min
Traction stress maximum 100 N 500 N
Weight per length 70 kg/km 149 kg/km
Permitted ambient conditions
Ambient temperature
• during operating -20 … +80 °C -40 … +80 °C
• during storage -20 … +80 °C -40 … +80 °C
• during transport -20 … +80 °C -40 … +80 °C
• during installation -20 … +80 °C -40 … +80 °C
Burning behaviour Flame retardant acc. to IEC 60332-1 Flame retardant acc. to IEC 60332-1
Chemical resistance
• to mineral oil Conditional resistance Resistant
• to grease Conditional resistance Resistant
• to water Conditional resistance Conditional resistance
Radiological resistance to Resistant Resistant
UV radiation
Product properties, functions,
components general
Product feature
• halogen-free No No
• silicon-free Yes Yes
Standards, specifications,
approvals
UL/ETL listing with 300 V rating Yes: CL3 No
UL/ETL style with 600 V rating Yes Yes
Verification of suitability
• CE mark Yes Yes
• RoHS conformity Yes Yes
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
PROFINET/Industrial Ethernet
Cabling technology
Energy cables
■ More information
Cable routing:
During storage, transport and cable laying, keep both ends
sealed with a shrink-on cap.
Comply with the permissible bending radii and tensile load!
Note:
You can order components supplementary to the SIMATIC NET
cabling range from your local contact.
Technical advice on this subject is available from:
J. Hertlein
I IA SC CI PRM 4
Phone: +49 (911) 750-4465
E-mail: juergen.hertlein@siemens.com
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
■ Overview ■ Benefits
■ Application
IE TP Cord RJ45/RJ45
G_IK10_XX_10092
Plug Plug
IE TP Cord RJ45/RJ45 can be used to directly connect individual components (10/100/1 000 Mbits/s)
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
■ Design ■ Function
• 2 x 2 cores for 10/100 Mbit/s transmission rate; The flexibility of the cable ensures easy installation, for example
4 x 2 cores for 10/100/1 000 Mbit/s transmission rate in a control cabinet, or to connect equipment in a control room.
• Two cores with two dummy elements twisted into a pair. The maximum length of an IE TP Cord is 10 m.
• Each pair is encased in plastic film and shielded with a
plastic-clad aluminum foil
Adapter cables are used to connect devices with a 9-pin ITP
interface to devices with an RJ45 interface. 2
• Outer woven shield around all pairs comprising tinned copper The IE TP Converter Cord 15/RJ45 is used to connect devices
wires with a 15-pin ITP interface to devices with an RJ45 interface.
• Plastic sheath (PVC)
IE TP Cord is available as TP Cord 4 x 2, pre-assembled cables
in the following versions:
• IE TP Cord RJ45/RJ45
with 2 x RJ45 plugs
• IE TP XP Cord RJ45/RJ45
with 2 x RJ45 plugs, send and receive cables are twisted.
IE TP Cord is available as TP Cord 2 x 2, pre-assembled cables
in the following versions:
• IE TP Cord 9/RJ45
with one 9-pole Sub-D connector and one RJ45 connector
• IE TP XP Cord 9/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
send and receive cable are twisted
• IE TP Cord 9-45/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
45° cable outlet
• IE TP XP Cord 9-45/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
45° cable outlet; send and receive cable are twisted
• IE TP XP Cord 9/9
with two 9-pole Sub-D connectors, send and receive cable
are twisted.
• IE TP Cord RJ45/15
with one RJ45 connector and one 15-pole Sub-D connector;
this is used to directly connect data terminals with ITP inter-
faces to network components with an RJ45 interface.
• IE TP XP Cord RJ45/15
with one RJ45 connector and one 15-pole Sub-D connector,
twisted send and receive cable; used for direct connection of
a data terminal with 15-pole Sub-D connector to a data
terminal with RJ45 plug.
• IE TP Converter Cord 15/RJ45
with a 15-pole Sub-D socket with slide locking and an
RJ45 plug. A retaining clip clamps it in place.
IE TP Converter Cord 15/RJ45 2 x 2 is used to connect data
terminals with an RJ45 interface to the ITP cabling system,
e.g. over the ITP Standard 9/15 cable.
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
■ Technical specifications
Article No. 6XV1870-3QH10 6XV1850-2JH10
Product-type designation IE TP Cord RJ45/RJ45, 4x2 IE TP Cord 9/RJ45, 2x2
Product description Patch cable, preferred length, preassembled Patch cable, preferred length, preassembled
2 Acceptability for application
with two RJ45 connectors
Easy connection of data terminals to the IE FC
with one 9-pole Sub-D connector an one RJ45 connector
Easy connection of data terminals to the IE FC
cabling system cabling system
Cable designation LI 02YSCH 4x2x0,15 PIMF GN FRNC LI 02YSCY 2x2x0,15/0,98 PIMF ICCS GN
Cable length 1m 1m
Electrical data
Damping ratio per length
• at 10 MHz maximum 86 dB/km 85 dB/km
• at 100 MHz maximum 28 dB/km 278 dB/km
• at 300 MHz maximum 501 dB/km 5 dB/km
• at 600 MHz maximum 735 dB/km 733 dB/km
Impedance
• for frequency range 100 100
1 MHz … 100 MHz
• for frequency range 100 100
10 MHz … 600 MHz
Relative symmetrical tolerance
• of the surge impedance at 15 % 15 %
1 MHz … 100 MHz
• of the surge impedance at 10 % 6%
10 MHz … 600 MHz
Transfer impedance at 10 MHz 10 m/m 10 m/m
Loop resistance per length maximum 290 /km 300 /km
Insulation resistance coefficient 500 G·m 500 G·m
Mechanical data
Number of electrical wires 8 4
Design of shield Overlapped aluminum-clad foil, sheathed in a braided Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires screen of tin-plated copper wires
AWG number - -
Core diameter
• of AWG26 core 0.5 mm 0.48 m
Outer diameter
• of the inner conductor 0.5 mm 0.48 mm
• of the wire insulation 1 mm 0.98 mm
• of the cable sheath 6.2 mm -
Symmetrical tolerance 0.3 mm -
of outer diameter of cable sheath
Width of the cable sheath - 5.8 mm
Symmetrical tolerance - 0.2 mm
of width of cable sheath
Thickness of the cable sheath - 3.7 mm
Symmetrical tolerance - 0.2 mm
of thickness of cable sheath
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
■ More information
You can order components supplementary to the SIMATIC NET
cabling range from your local contact.
Technical advice on this subject is available from:
J. Hertlein
I IA SC CI PRM 4
Phone: +49 (911) 750-4465
E-mail: juergen.hertlein@siemens.com
PROFINET/Industrial Ethernet
Cabling technology
Pre-assembled IE Connecting Cables
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Cabling technology
Pre-assembled IE Connecting Cables
■ Technical specifications
Article No. 6XV1870-8AH10 6XV1871-5TN10
Product-type designation IE Connecting Cable M12-180/M12-180 IE Connecting Cable M12-180/IE FC RJ45-145
Product description Flexible connecting cable (4-core), preferred length, Flexible connecting cable (4-core), preferred length,
2 preassembled with two 4-pole M12 connectors (D-coded) preassembled with one 4-pole M12 connector (D-coded)
and one IE FC RJ45 Plug 145
Acceptability for application For connecting Industrial Ethernet stations For connecting Industrial Ethernet stations
(e.g. SIMATIC ET200pro and SCALANCE X208PRO) (e.g. SIMATIC ET200pro, SCALANCE X208PRO and
to IP 65/67 degree of protection SIMOTION)
Cable designation 2YY (ST) CY 2x2x0,75/1,5-100 LI GN 2YY (ST) CY 2x2x0,75/1,5-100 LI GN
Cable length 1m 10 m
Electrical data
Damping ratio per length
• at 10 MHz maximum 63 dB/km 63 dB/km
• at 100 MHz maximum 213 dB/km 213 dB/km
Impedance for frequency range 100 100
1 MHz … 100 MHz
Relative symmetrical tolerance 5% 5%
of the surge impedance at
1 MHz … 100 MHz
Near-end crosstalk per length at 500 dB/km 500 dB/km
1 MHz ... 100 MHz
Transfer impedance at 10 MHz 20 m/m 20 m/m
Loop resistance per length 120 /km 120 /km
maximum
Percentage NVP value 66 % 66 %
Mechanical data
Number of electrical wires 4 4
Design of shield Overlapped aluminum-clad foil, sheathed in a braided Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires screen of tin-plated copper wires
Design of the electrical connection - -
FastConnect
AWG number - -
Core diameter of the AWG22 core 0.75 mm 0.75 mm
Outer diameter
• of the inner conductor 0.75 mm 0.75 mm
• of the wire insulation 1.5 mm 1.5 mm
• of the inner sheath of the cable 3.9 mm 3.9 mm
• of the cable sheath 6.5 mm 6.5 mm
Symmetrical tolerance of 0.2 mm 0.2 mm
outer diameter of cable sheath
Material
• of the wire insulation PE PE
• of the inner sheath of the cable PVC PVC
• of the cable sheath PVC PVC
Color
• of the insulation of data wires white / yellow / blue / orange white / yellow / blue / orange
• of the cable sheath green green
Bending radius
• with single bend minimum 32.5 mm 32.5 mm
permissible
• with multiple bends minimum 49 mm 49 mm
permissible
• with continuous bending 100 mm 100 mm
Number of bending cycles 3 000 000 3 000 000
• Note For use in cable carriers, for 3 million bending cycles For use in cable carriers, for 3 million bending cycles
with a bending radius of 100 mm, a speed of 4 m/s, with a bending radius of 100 mm, a speed of 4 m/s,
and an acceleration of 4 m/s² and an acceleration of 4 m/s²
Traction stress maximum 150 N 150 N
Weight per length 68 kg/km 68 kg/km
PROFINET/Industrial Ethernet
Cabling technology
Pre-assembled IE Connecting Cables
PROFINET/Industrial Ethernet
Cabling technology
Pre-assembled IE Connecting Cables
2
Cable GP 2 x 2 (PROFINET Type C) Preassembled IE FC TP trailing
with two 4-pin M12 plugs (D-coded) cable GP 2 x 2 (PROFINET type C)
up to 85 m, with two IE FC RJ45 plug-180,
IP65/IP67 degree of protection IP20 degree of protection;
Length: length:
• 0.3 m 6XV1870-8AE30 • 1.0 m 6XV1871-5BH10
• 0.5 m 6XV1870-8AE50 • 2.0 m 6XV1871-5BH20
• 1.0 m 6XV1870-8AH10 • 3.0 m 6XV1871-5BH30
• 1.5 m 6XV1870-8AH15 • 5.0 m 6XV1871-5BH50
• 2.0 m 6XV1870-8AH20 • 10 m 6XV1871-5BN10
• 3.0 m 6XV1870-8AH30 • 15 m 6XV1871-5BN15
• 5.0 m 6XV1870-8AH50 • 20 m 6XV1871-5BN20
• 10 m 6XV1870-8AN10 M12 Power Connecting Cable
• 15 m 6XV1870-8AN15 M12-180/M12-180
IE Connecting Cable Flexible 4-core power
M12-180/IE FC RJ45 Plug-145 connecting cable, assembled
Pre-assembled IE FC TP trailing with A-coded 5-pin M12 connector
cable GP 2 x 2 (PROFINET type C) and A-coded, 5-pin M12 socket
with M12 plug (D-coded) to supply the ET 200 with 24 V DC;
and IE FC RJ45 plug, length:
IP65/IP67 degree of protection • 0.3 m 6XV1801-5DE30
Length: • 0.5 m 6XV1801-5DE50
• 2.0 m 6XV1871-5TH20 • 1.0 m 6XV1801-5DH10
• 3.0 m 6XV1871-5TH30 • 1.5 m 6XV1801-5DH15
• 5.0 m 6XV1871-5TH50 • 2.0 m 6XV1801-5DH20
• 10 m 6XV1871-5TN10 • 3.0 m 6XV1801-5DH30
• 15 m 6XV1871-5TN15 • 5.0 m 6XV1801-5DH50
• 10 m 6XV1801-5DN10
• 15 m 6XV1801-5DN15
Additional special lengths See
with 90° or 180° cable outlet http://support.automation.sie-
mens.com/WW/view/en/26999294
PROFINET Cabling and http://www.profinet.com
Interconnection Technology
Guideline
■ More information
Note:
You can order components supplementary to the SIMATIC NET
cabling range from your local contact.
Technical advice on this subject is available from:
J. Hertlein
I IA SC CI PRM 4
Phone: +49 (911) 750-4465
E-mail: juergen.hertlein@siemens.com
PROFINET/Industrial Ethernet
Cabling technology
IE FC Outlet RJ45
■ Overview ■ Benefits
■ Application
The IE FC Outlet RJ45 is used as a transition from the rugged
Industrial Ethernet FC cables used in the industrial environment
• Simple design of structured twisted-pair cabling to prefabricated TP Cord cables (10/100 Mbit/s) using an
RJ45 socket.
• Extremely short installation times thanks to insulation
displacement method By connecting several IE FC Outlet RJ45 devices in series,
• Rugged full-metal module certified according to Category 5 a patch field can be constructed with the required connection
density (e.g. 16 outlets over 19" width).
• Reliable shield contact and strain relief thanks to bolt-on
cover
• Color marking prevents errors
■ Design
The IE FC Outlet RJ45 has a rugged metal housing and satisfies
Category 5 of the international cable standard ISO/IEC 11801
and EN 50173. It is suitable both for mounting on rails and wall
mounting by means of four through holes.
The Outlet RJ45 can also be mounted behind a metal plate with
a cutout (e.g. in a control cabinet).
The Outlet RJ45 has the following connections
• 4 insulation-piercing contacts for connecting the Industrial
Ethernet FC cable 2 x 2 (contacts are color coded)
• RJ45 socket with dust protection cap for connecting different
TP Cord cables (10/100 Mbit/s).
■ Function
The Industrial Ethernet FC Outlet RJ45 is attached directly to the
Industrial Ethernet FC cable 2 x 2.
For connection between IE Outlet RJ45 and network compo-
nents or a terminal device, various preassembled RJ45 patch
cables (10/100 Mbit/s) are available.
PROFINET/Industrial Ethernet
Cabling technology
IE FC Outlet RJ45
■ Technical specifications
Article No. 6GK1901-1FC00-0AA0 Article No. 6GK1901-1FC00-0AA0
Product-type designation IE FC outlet RJ45 Product-type designation IE FC outlet RJ45
Electrical data Permitted ambient conditions
2 Transfer rate 1 10 Mbit/s Ambient temperature
• during operating -25 … +70 °C
Transfer rate 2 100 Mbit/s
• during storage -40 … +70 °C
Interfaces • during transport -40 … +70 °C
Number of electrical connections Protection class IP IP20
• for Industrial Ethernet FC TP cables 1
• for network components and termi- 1 Standards, specifications,
nal equipment approvals
PROFINET/Industrial Ethernet
Cabling technology
IE FC Outlet RJ45
2
graded prices cable for connection to
from 10 and 50 units on IE FC Outlet RJ45/ IE FC RJ45
Plug 180/90 for use as
IE TP Cord RJ45/RJ45 trailing cable;
TP cable 2 x 2 PROFINET-compatible;
with two RJ45 plugs with UL approval;
• 0.5 m 6XV1850-2GE50 sold by the meter;
max. length 1 000 m,
•1m 6XV1850-2GH10
minimum order 20 m
•2m 6XV1850-2GH20
•6m 6XV1850-2GH60 IE FC TP Festoon Cable GP 2 x 2 6XV1871-2S
• 10 m 6XV1850-2GN10 (Type B)
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
■ Overview ■ Application
The 8-core cabling system of SIMATIC NET allows transfer rates
of 10/100/1000 Mbit/s for Ethernet and for the service-indepen-
dent cabling from this office environment. Thanks to the 8-core
cabling it is now possible to implement two Industrial Ethernet
2 connections for Fast Ethernet, but in future it will also be possible
to upgrade to a Gigabit Ethernet connection. This implements
the transition from 4-core Industrial Ethernet FastConnect TP
cabling system to the 8-core Gigabit cabling system.
The FC RJ45 Modular Outlet base module can optionally be
equipped with two different replaceable inserts, as follows:
• IE FC RJ45 Modular Outlet Insert 2FE with
2 x RJ45 sockets for 100 Mbit/s systems
• IE FC RJ45 Modular Outlet Insert 1GE with
1 x RJ45 socket for 1 000 Mbit/s systems
Thus it is possible not only to implement individual device
connections, but also 100 Mbit/s dual connections.
By replacing the insert, it is possible to switch from network
structures that are operated at transfrer rates of 100 Mbit/s to
• Simple connection technology (insulation displacement structures with rates of 1 000 Mbit/s. Replacement of the cabling
contacts) for 8-core Industrial Ethernet FastConnect twisted is not necessary (permanent cabling).
pair installation cables (Cat6)
• Safe connection technology thanks to visible connection area Like the 4-wire cabling system, the Gigabit cabling system with
the IE FC RJ45 Modular Outlet also takes the conditions in the
• Industry-standard design field of industrial automation into account. No special tools are
- Rugged metal housing required for the assembly; the same FC stripping tool is used as
- Dust caps for the 4-wire system.
• Wall and DIN rail mounting inside or outside control cubicles 8-wire FC installations cables are used for the cabling (AWG 22):
thanks to IP40 protection
• IE FC Standard Cable 4 x 2;
• Good electromagnetic shielding and conduction due to metal for fixed routing as standard type for the IE FC RJ45 Modular
housing Outlet Inserts 2FE and 1GE
• Integral strain relief for 8-core installation cables
Max. distance which can be covered between two IE FC
• Replaceable inserts for Modular Outlets using IE FC Standard Cable is 90 m; the total
- 2 x Fast Ethernet connection length of the patch cords to the terminal units at each end must
IE FC RJ45 Modular Outlet Insert 2FE not exceed 10 m.
- 1 x Gigabit Ethernet connection
IE FC RJ45 Modular Outlet insert 1GE
■ Benefits
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
■ Application (continued)
Application examples
Terminal device,
e.g. S7-1500
Terminal device,
e.g. S7-1500
2
IE FC Cable 4x2
Insert 2FE (AWG 22) Insert 2FE
Terminal device, Terminal device,
e.g. S7-1500 e.g. S7-1500
G_IK10_XX_10036
If components that do not support autocrossing are used,
an IE TP XP cord must be used between two network components or terminals.
IE TP Cord can be used with IE FC RJ45 Modular Outlet with Insert 2FE (10/100 Mbit/s)
zjhshujlG z^TZWWV[WWG
jwG[ZTXGh
plGmjGyq[\G plGmjGyq[\G
tGv tGv
plG{wGj plGmjG{wGjG[YGOh~nGYYP plG{wGj
pG pG
wjGGjwGX]YZ
plGmjG{wGzGjGGnwG[Y
nprXWXWW`X
plG{wGjGyq[\Vyq[\ plG{wGjGyq[\Vyq[\
Oh~nGYYP
pGGGGGGGGS
GplG{wGwGGGGGGGGGG
IE TP Cord RJ45/RJ45 can be used for patch technology with IE FC RJ45 Modular Outlet with Insert 1GE (10/100/1 000 Mbit/s)
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
■ Design
IE FC RJ45 Modular Outlet (base modules) Ports:
• Robust metal housing, complies with Category 6 of the inter- • 8 insulation displacement contacts for connection of the
national cabling standards ISO/IEC 11801 and EN 50173 8-core Industrial Ethernet FC installation cables
1 2 Jack screw 3
Open
cover
4 5 6
Wires
in the
guides
Connect cable: Close cover Push insert into end position. Tighten the
Press down insulation displacement interlocking screws of the strain-relief,
contacts push insert in, tighten jack screw
7 8 9
G_IK10_XX_30029
Outlet assembly complete Outlet ready for use Exchanging the insert: Insert can be
replaced while basic housing is closed
by pulling it past the pre-engaged
position.
Mounting instructions
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
■ Function
The IE FC RJ45 Modular Outlet is connected direct to the 8-core A maximum of 80 m can be covered between the Outlet and the
Industrial Ethernet FC cables 4 x 2. Pre-assembled RJ45 patch IP67 hybrid connector. The connection between Outlet and data
cables (TP cord) are available for the connection between outlet terminal can be established using a patch cable with a
and network component or data terminal. These conform with maximum length of 6 m.
Cat6 of the international cabling standards. 2
When housing is opened, colored markings on the contact ele-
ment simplify connection of the individual wires to the insulation
displacement contacts.
S7-300
S7-400
SCALANCE SCALANCE IE TP Cord
XM-400 XM-400
IE TP Cord
ET 200S
G_IK10_XX_10086
Outlet Outlet
Insert 1GE Insert 1GE
IE FC Standard Cable 4x2 IE FC Standard Cable 4x2
1000 Mbit/s connection 1 x 1000 Mbit/s
connection
IE TP Cord IE TP Cord
System configuration with IE FC RJ45 Modular Outlet System configuration with IE FC RJ45 Modular Outlet 100 Mbit/s
and IE FC Outlet RJ45 and 1 000 Mbit/s
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
■ Technical specifications
Article No. 6GK1901-1BE00-0AA0 6GK1901-1BE00-0AA1 6GK1901-1BE00-0AA2 6GK1901-1BE00-0AA3
Product-type designation IE FC RJ45 modular outlet IE FC RJ45 modular outlet IE FC RJ45 modular outlet IE FC RJ45 modular outlet
(without insert) (insert 2FE) (insert 1GE) (power insert)
2 Electrical data
Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 10 Mbit/s
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Transfer rate 3 1 000 Mbit/s - 1 000 Mbit/s -
Interfaces
Number of electrical connections
• for Industrial Ethernet FC TP cables 1 1 1 1
• for network components - 2 1 1
and terminal equipment
Design of the electrical connection
• for Industrial Ethernet FC TP cables integrated insulation integrated insulation integrated insulation integrated insulation
displacement contacts displacement contacts displacement contacts displacement contacts
• for FC RJ45 modular outlet insert - 2 x RJ45 socket - -
2FE (10/100 Mbit/s)
• for FC RJ45 modular outlet insert - - 1 x RJ45 socket -
1GE (10/100 Mbit/s)
• for FC RJ45 modular outlet - - - 1 x RJ45 socket
power insert (10/100 Mbit/s),
1 x 24 V DC terminal
• FastConnect Yes Yes Yes Yes
Mechanical data
Material of the enclosure metal metal metal metal
Design, dimensions and weight
Width 50 mm 50 mm 50 mm 50 mm
Height 115.25 mm 115.25 mm 115.25 mm 115.25 mm
Depth 58.95 mm 58.95 mm 58.95 mm 58.95 mm
Net weight 450 g 450 g 450 g 450 g
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
Permitted ambient conditions
Ambient temperature
• during operating -20 … +70 °C -20 … +70 °C -20 … +70 °C -20 … +70 °C
• during storage -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
• during transport -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP40 IP40 IP40 IP40
Standards, specifications,
approvals
Verification of suitability Yes Yes Yes Yes
RoHS conformity
Verification of suitability Yes Yes Yes Yes
UL-registration
Standard for structured cabling Cat 6 Cat 6 Cat 6 Cat 6
PROFINET/Industrial Ethernet
Cabling technology
IE FC RJ45 Modular Outlet
2
for a replaceable insert; sold by the meter
• without replaceable insert 6GK1901-1BE00-0AA0 IE TP Cord see IE TP Cord
• With 2FE insert; 6GK1901-1BE00-0AA1
replaceable insert for 8-core patch cable for connection
2 x 100 Mbit/s interfaces between
• With 1GE insert; 6GK1901-1BE00-0AA2 FC Modular Outlet base modules
replaceable insert for and data terminal;
1 x 1 000 Mbit/s interfaces available in different lengths
PROFINET/Industrial Ethernet
Cabling technology
Overview of FC-FOCs
■ Overview ■ Design
Fiber-optic cables with glass core (62.5/200/230) are offered for
the FastConnect fiber-optic cable system:
• FC glass fiber-optic cable;
2
duplex cable for indoor and outdoor fiber-optic networks
The fiber structure corresponds to that of the PCF. This allows
simple assembly on site.
Sheath material Application
PVC Standard use in indoor and outdoor
areas of industrial applications
PUR Highly mobile applications (tow
chains) for high mechanical or chemi-
cal stress in harsh industrial environ-
ments
PE Routing of cables in moist areas
indoors and outdoors, and for direct
burying in earth
FRNC Standard applications with high fire
protection requirements
• Simple on-site assembly of glass FOC in the field
• Optical signal transmission Approvals
• No radiation emission from the cable UL listing (safety standard) for network lines is especially neces-
• Unaffected by external noise fields sary for the American and Canadian markets. The requirements
for the appropriate approvals depend on where the cable is
• No grounding problems routed within the building. This applies to all cables which have
• Electrical isolation to be routed from a machine to a remote control cabinet and are
• Low weight positioned on cable racks secured in the building. These cables
are identified by the suffix "GP" (general purpose) in the product
• Simple laying of cables name and have the corresponding UL approvals.
PROFINET/Industrial Ethernet
Cabling technology
Overview of FC-FOCs
■ Application
The fiber-optic cable (FOC) is used for the transmission of sig- The FastConnect fiber-optic (FC FO) system enables fast on-site
nals in very extensive plants and where there are significant po- assembly of glass fiber-optic cables with the right lengths to suit
tential differences within a plant. The light beam is guided by to- the respective application.
tal reflection at the transition from core to cladding which has a
lower refractive index than the core. 2
Assembly with FastConnect for glass fiber-optic cables
1 2 3 4
5 6 7 8
5 6 7
G_IK10_XX_10321
Steps for assembly of Industrial Ethernet fiber-optic cables with Industrial Ethernet FastConnect
PROFINET/Industrial Ethernet
Cabling technology
FC glass fiber-optic cables
■ Overview ■ Design
fleece wrapping
G_IK10_XX_10263
with strain relief
strain relief
elements
FC FO fiber using aramide
62.5/200/230 µm yarn
hollow core
• FastConnect standard fiber-optic cable for use in optical FC FO Standard Cable GP (General Purpose);
Industrial Ethernet and PROFIBUS networks rugged round cable with green outer sheath, Kevlar strain relief
• For all users who want to install and assemble the glass fiber- elements, and 62.5/200/230 FC FO fibers for indoor/outdoor
optic cables themselves over longer distances on site for applications
office or industrial applications. FC FO Trailing Cable;
• Simple FastConnect SC/BFOC connector assembly on site rugged round cable with green outer sheath, Kevlar strain relief
• Rugged construction for industrial applications both indoors elements and 62.5/200/230 FC FO fibers for use in tow chains
and outdoors and moving applications
• High interference immunity, as they are not sensitive to Maximum cable length between two devices:
electromagnetic interference • 3 000 m for 100 Mbit/s Ethernet or for PROFIBUS
• Extensive range of approvals (UL approvals) • 350 m for 1 000 Mbit/s Ethernet (1000Base-SX)
• 550 m for 1 000 Mbit/s Ethernet (1000Base-LX)
■ Benefits The maximum cable lengths can be assembled from partial
lengths using FastConnect couplings (SC or BFOC; maximum
two couplings, approx. 2.5 dB attenuation per coupling).
It is also possible to combine existing installed, conventional
62.5/125 µm multimode glass fiber-optic cable sections with the
• Avoidance of excessive cable lengths in the control cabinet, FastConnect fiber-optic cables.
as the fiber-optic cables can be assembled to the right length
on site
• Easy installation of cables in buildings, as cables can be
pulled in without connectors attached
• Simple extension of installed glass fiber-optic cables via SC
and BFOC couplers
• Devices with different connection method (SC or BFOC) can
easily be connected to one another using self-assembled
adapter cables
• Electrical isolation of Industrial Ethernet/PROFINET/
PROFIBUS devices
• Unaffected by electromagnetic interference
• Tap-proof: no radiation from cable
■ Application
SIMATIC NET FastConnect glass fiber-optic cables are used
to construct optical indoor and outdoor Industrial Ethernet/
PROFINET and PROFIBUS networks. Devices with integral
optical interface (SC or BFOC connection technology) are,
for example, optical link modules (OLM) and SCALANCE X
Industrial Ethernet switches.
FastConnect glass fiber-optic cables are to be assembled on
site using FastConnect SC or FastConnect BFOC connectors.
A corresponding assembly kit (FC FO Termination Kit) is avail-
able for this purpose. The Termination Kit permits the stripping
and the "cleaving" of the fiber in the assembled connector, as is
familiar from PCF fiber-optic cables. To extend existing lines, a
BFOC or SC coupler may be used depending on the connection
technology.
PROFINET/Industrial Ethernet
Cabling technology
FC glass fiber-optic cables
■ Technical specifications
Article No. 6XV1847-2A 6XV1847-2C
Product-type designation FC FO standard cable GP FC FO trailing cable
Product description Glass fiber-optic cable for assembly in the field, Flexible glass fiber-optic cable for assembly in the field,
PROFINET/Industrial Ethernet
Cabling technology
FC glass fiber-optic cables
2 Ambient temperature
• during operating -40 … +85 °C -25 … +75 °C
• during storage -40 … +85 °C -30 … +75 °C
• during transport -40 … +85 °C -30 … +75 °C
• during installation -5 … +50 °C -5 … +50 °C
Burning behaviour Flame-retardant in accordance with IEC 60332-1-2 and Flame-retardant in accordance with IEC 60332-1-2
IEC 60332-3-22 (Cat. A)
Chemical resistance
• to mineral oil Conditional resistance Resistant
• to grease Conditional resistance Resistant
• to water Conditional resistance Conditional resistance
Radiological resistance to Resistant Resistant
UV radiation
Product properties, functions,
components general
Product feature
• halogen-free No No
• silicon-free Yes Yes
Product component Rodent protection No No
Cable length for glass FOC
• for 100BaseFX 3 000 m 3 000 m
for Industrial Ethernet maximum
• for 1000BaseSX 350 m 350 m
for Industrial Ethernet maximum
• for 1000BaseLX 550 m 550 m
for Industrial Ethernet maximum
• for PROFIBUS maximum 3 000 m 3 000 m
Standards, specifications,
approvals
Verification of suitability UL approval: OFN (NEC Article 770, UL 1651) / -
CSA approval: OFN 90 Cel, FT1, FT4
(CSA standard C22.2 No232-M1988)
• RoHS conformity Yes Yes
PROFINET/Industrial Ethernet
Cabling technology
FC glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
FC glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
FC FO termination kit
■ Overview ■ Design
fleece wrapping
G_IK10_XX_10263
with strain relief
strain relief
elements
FC FO fiber using aramide
62.5/200/230 μm yarn
hollow core
PROFINET/Industrial Ethernet
Cabling technology
Overview of FOCs
Approvals
■ Overview
UL listing (safety standard) for network cables is especially
necessary for the American and Canadian markets. The require-
ments for the appropriate approvals depend on where the cable
is routed within the building. This applies to all cables which
2
have to be routed from a machine to a remote control cabinet
and are positioned on cable racks secured in the building.
These cables are identified by the suffix "GP" (general purpose)
in the product name and have the corresponding UL approvals.
Product overview
PROFINET fiber optic, PCF and POF cable
PROFINET PROFINET
Type B Type C
fixed or flexible extremely
cable depend- flexible, continu-
ing on cable ous movement,
design vibrations or
torsion loading,
also for special
applications
Fiber Optic Cable 2x 50/125μ
• Optical signal transmission
FO Standard Cable GP – •
• No radiation along the cable 6XV1 873-2A
• Unaffected by external noise fields FO FRNC Cable • –
6XV1 873-2B
• No grounding problems
• Electrical isolation FO Trailing Cable – •
6XV1 873-2C
• Low weight FO TP Trailing Cable GP – •
• Easy routing 6XV1 873-2D
FO Ground Cable – •
■ Application 6XV1873-2G
FO Robust Cable GP – •
The fiber optic (FO) cable is used for transmitting signals with
the help of waves in the optical frequency range. The light beam FO Robust Cable GP 4x 9/125/900μ – –
is guided by total reflection at the transition from core to cladding PCF Cable 2x 200/230μ
which has a lower refractive index than the core. PCF Standard Cable GP • –
The fiber optic cable is provided with a protective coating. 6XV1 861-2A
The term “fiber” is often also used for fiber-optic cables (FOC). PCF Tailing Cable • –
6XV1 861-2C
■ Design PCF Tailing Cable GP
6XV1 861-2C
• –
Fiber-optic cables with glass fibers , PCF fibers (Polymer POF Cable 2x 980/1 000μ
Cladded Fiber) and POF fibers (Polymer Optical Fiber) are
offered for Industrial Ethernet: POF Standard Cable GP • –
6XV1 874-2A
• Glass fiber-optic cable;
duplex cable for fiber-optic networks indoors and outdoors POF Trailing Cable – •
6XV1 874-2B
• POF fiber-optic cable;
Duplex cable for POF networks in the indoor area
• PCF fiber-optic cable;
duplex cable for PCF networks indoors and outdoors
Sheath material Application
PVC Standard use in indoor and outdoor
areas of industrial applications
PUR Highly mobile applications
(tow chains) for high mechanical or
chemical stress in harsh industrial
environments
PE Routing of cables in moist areas
indoors and outdoors, and for direct
burying in earth
FRNC Standard applications with high fire
protection requirements
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
■ Overview ■ Application
Marine duplex FOC SIENOPYR
Halogen-free, non-crush, flame-retardant, marine-approved
fiber-optic cable for permanent installation on ships and offshore
platforms indoors and on open deck. Sold by the meter
Fiber-optic indoor cable
2
Halogen-free fiber-optic cable, non-crush, flame-retardant, for
installation inside buildings (e.g. in production halls and in
building automation). Supplied in fixed lengths, pre-assembled
with four BFOC connectors.
Standard FOC/FRNC cable
Fiber-optic cables for the following application areas indoors
and outdoors
• For routing above ground
• For installation inside buildings.
Sold by the meter and in fixed lengths, pre-assembled with four
BFOC connectors or four SC connectors.
Fiber-optic trailing cable
Fiber-optic cables for the special application of forced motion
control, such as in continuously moving machine parts (in trailing
cables) indoors and outdoors. Two cable variants are available
for this application:
• Used for the optical Industrial Ethernet and PROFIBUS • FO Trailing Cable;
networks Cable for high mechanical stress, PUR outer sheath,
• Rugged design for industrial applications indoors and no UL approval
outdoors • FO Trailing Cable GP (general purpose);
• Halogen-free design for installation inside buildings Cable for low mechanical stress, PVC outer sheath,
with UL approval
• Trailing cable for the special application of forced motion
control Sold by the meter and in fixed lengths, pre-assembled with four
• High immunity to noise thanks to insensitivity to electro- BFOC connectors or four SC connectors.
magnetic fields Fiber-optic outdoor cable
• Available preassembled
Waterproof cable (lengthwise and sideways) for use outdoors
• Extensive approvals (UL) with non-metallic protection against rodents for laying into the
ground.
■ Benefits Sold by the meter and in fixed lengths, pre-assembled with four
BFOC connectors or four SC connectors.
Note:
Special tools and specially trained personnel are required for
• Easy routing with pre-assembling glass fiber-optic cables
- Pre-assembled cables
- No grounding problems
- Very light fiber-optic cable
• Tap-proof
due to lack of radiation from the cable
• Silicon-free;
therefore suitable for use in the automotive industry
(e.g. on paint shop conveyors)
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
■ Application (continued)
Application examples
Plug Plug
2 SC
Preassembled FOC with SC connectors
SC
connection connection
G_IK10_XX_10039
SCALANCE XM-400 SCALANCE XM-400
FO Trailing Cable GP 50/125
FO Trailing Cable 50/125
FO Ground Cable 50/125
FO FRNC Cable 50/125
Plug Plug
Preassembled FOC with BFOC connectors
BFOC BFOC
connection connection
G_IK10_XX_10043
SCALANCE XM-400 SCALANCE XM-400
FO Trailing Cable GP (50/125)
FO Trailing Cable (50/125)
FO Ground Cable (50/125)
FO FRNC Cable 50/125
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
■ Design
Cable types 50/125 μm 62.5/125 μm 9/125 μm
FO standard cable GP • – –
(50/125/1 400)
Outer sheath
FO FRNC cable
(50/125/1 400)
• – –
2
FO trailing cable • – –
Single-core sheath (50/125/1 400)
Hollow core FO trailing cable GP • – –
DUG& DEOH (50/125/1 400)
)26WDQG
FO ground cable • – –
(50/125/1 400)
FO robust cable GP • – –
G_IK10_XX_10030
(50/125/900)
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
■ Technical specifications
Article No. 6XV1873-2A 6XV1873-2B 6XV1873-2G
Product-type designation FO Standard Cable GP FO FRNC Cable GP FO Ground Cable
Product description Glass fiber-optic cable, sold by the Glass fiber-optic cable, sold by the Glass fiber-optic cable, sold by the
2 Acceptability for application
meter, unassembled
Cable for indoor and outdoor use,
meter, unassembled
Halogen-free cable for indoor
meter, unassembled
Cable with longitudinal and lateral
UL approval and outdoor use, for fixed installation, water tightness with non-metallic
UL approval protection against rodents for outdoor
use and for direct laying in soil.
Version of the assembled FO cable can be assembled with four BFOC or can be assembled with four BFOC or can be assembled with four BFOC or
SC connectors SC connectors SC connectors
Cable designation AT-W(ZN)YY 2x1 G 50/125 AT-W(ZN)HH 2G 50/125 UV AT-WQ(ZN)Y(ZN)B2Y 2G 50/125
Optical data
Damping ratio per length
• at 850 nm maximum 2.7 dB/km 2.7 dB/km 2.7 dB/km
• at 1 300 nm maximum 0.7 dB/km 0.7 dB/km 0.7 dB/km
Bandwidth length product
• at 850 nm 600 GHz·m 600 GHz·m 600 GHz·m
• at 1 300 nm 1 200 GHz·m 1 200 GHz·m 1 200 GHz·m
Mechanical data
Number of fibers per FOC core 1 1 1
Number of FOC cores per FOC cable 2 2 2
Version of the FO conductor fiber Multi-mode gradient fiber 50/125 µm, Multi-mode gradient fiber 50/125 µm, Multi-mode gradient fiber 50/125 µm,
OM 2 OM 2 OM 2
Design of the FOC core Hollow core, filled, Hollow core, filled, Hollow core, filled,
diameter 1400 µm diameter 1400 µm diameter 1400 µm
Design of the fiber-optic cable Segmentable Segmentable Segmentable
Outer diameter
• of optical fibers 50 µm 50 µm 50 µm
• of the optical fiber sheath 125 µm 125 µm 125 µm
• of the FOC core sheath 2.9 mm 2.9 mm 2.9 mm
• of the cable - 9.2 mm 10.5 mm
Symmetrical deviation
• of the outer diameter 0.1 mm 0.1 mm 0.1 mm
of the FOC core sheath
• of the outer diameter of the line - 0.3 mm 0.5 mm
Width of the cable sheath 7.4 mm - -
Thickness of the cable sheath 4.5 mm - -
Material
• of the fiber-optic cable core Quartz glass Quartz glass Quartz glass
• of the optical fiber sheath Quartz glass Quartz glass Quartz glass
• of the FOC core sheath PVC FRNC PVC
• of the fiber-optic cable sheath PVC FRNC PE
• of the strain relief Aramide fibers Aramide fibers Aramide fibers
Color
• of the FOC core sheath orange / black orange / black orange / black
• of the cable sheath green green black
Bending radius
• with single bend 45 mm 90 mm 105 mm
• minimum permissible
• with multiple bends 65 mm 135 mm 155 mm
• minimum permissible
Traction stress maximum 500 N 500 N 800 N
Short-term shear force per length 600 N/cm 500 N/cm 500 N/cm
Continuous lateral force per length 400 N/cm - 300 N/cm
Weight per length 40 kg/km 85 kg/km 90 kg/km
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
2 Acceptability for application Cable with longitudinal and lateral water tightness
with non-metallic protection against rodents
Cable with longitudinal and lateral water tightness
with non-metallic protection against rodents
for outdoor and indoor use and for direct laying in soil for outdoor and indoor use and for direct laying in soil
Version of the assembled FO cable can be assembled with tho BFOC, SC and can be assembled with tho BFOC, SC and
LC duplex plugs LC duplex plugs
Cable designation AT-V(ZN)H(ZN)BH 2G50/125 AT-V(ZN)H(ZN)BH 4E9/125
Optical data
Damping ratio per length
• at 850 nm maximum 2.7 dB/km -
• at 1 300 nm maximum 1 dB/km 0.5 dB/km
• at 1 550 nm maximum - 0.5 dB/km
Bandwidth length product
• at 850 nm 600 GHz·m -
• at 1 300 nm 1 200 GHz·m -
Mechanical data
Number of fibers per FOC core 1 1
Number of FOC cores per FOC cable 2 4
Version of the FO conductor fiber Multi-mode gradient fiber 50/125/245 µm, OM2 Single mode fiber 4E9/125/900, OS1 and OS2
Design of the FOC core Solid core, diameter 900 µm Solid core, diameter 900 µm
Design of the fiber-optic cable Segmentable Segmentable
Outer diameter
• of optical fibers 50 µm 9 µm
• of the optical fiber sheath 125 µm 125 µm
• of the FOC core sheath 2.2 mm 2.2 mm
• of the cable 7.5 mm 9 mm
Material
• of the fiber-optic cable core Quartz glass Quartz glass
• of the optical fiber sheath Quartz glass Quartz glass
• of the FOC core sheath PE flame retardant PE flame retardant
• of the fiber-optic cable sheath PE flame retardant PE flame retardant
• of the strain relief Aramide fibers and glass roving Aramide fibers, plus central support element
and glass roving
Color
• of the FOC core sheath orange / black, with directional arrow orange / black, with directional arrow
(numbering of the core pairs with 1 and 2)
• of the cable sheath Black Black
Bending radius
• with single bend minimum permissi- 25 mm 90 mm
ble
• with multiple bends minimum per- 40 mm 135 mm
missible
Traction stress maximum 1 000 N 1 000 N
Short-term shear force per length 600 N/cm 600 N/cm
Continuous lateral force per length 200 N/cm 200 N/cm
Weight per length 67 kg/km 87 kg/km
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
2
sold by the meter;
Acceptability for application For connection of fiber-optic cables max. delivery unit 1 000 m;
minimum order 20 m;
Transmission rate
Preferred lengths 1)
Transfer rate pre-assembled
• 1 for Industrial Ethernet 10 Mbit/s with 4 BFOC connectors
• 2 for Industrial Ethernet 100 Mbit/s • 0.5 m 6XV1873-3AH05
• 3 for Industrial Ethernet 1 000 Mbit/s •1m 6XV1873-3AH10
• with PROFIBUS 9.6 kbit/s … 12 Mbit/s •2m 6XV1873-3AH20
Interfaces •3m 6XV1873-3AH30
•5m 6XV1873-3AH50
Number of optical interfaces 1
for optical waveguide • 10 m 6XV1873-3AN10
• 15 m 6XV1873-3AN15
Design of optical connections BFOC connector • 20 m 6XV1873-3AN20
for network components or terminal
devices • 30 m 6XV1873-3AN30
• 40 m 6XV1873-3AN40
Design of the electrical connection No
• 50 m 6XV1873-3AN50
FastConnect
• 80 m 6XV1873-3AN80
Mechanical data • 100 m 6XV1873-3AT10
Material of the enclosure Metal and plastic • 150 m 6XV1873-3AT15
• 200 m 6XV1873-3AT20
Design, dimensions and weight
• 300 m 6XV1873-3AT30
Type of cable outlet 180 degree cable outlet
Preferred lengths 1)
Width 10 mm pre-assembled
with 4 SC connectors
Height 10 mm
• 0.5 m 6XV1873-6AH05
Depth 10 mm •1m 6XV1873-6AH10
Net weight 8g •2m 6XV1873-6AH20
•3m 6XV1873-6AH30
Permitted ambient conditions
•5m 6XV1873-6AH50
Protection class IP IP20 • 10 m 6XV1873-6AN10
Product properties, functions, • 15 m 6XV1873-6AN15
components general • 20 m 6XV1873-6AN20
Product feature silicon-free Yes • 30 m 6XV1873-6AN30
• 40 m 6XV1873-6AN40
Product component strain relief Yes
• 50 m 6XV1873-6AN50
Standards, specifications, • 80 m 6XV1873-6AN80
approvals • 100 m 6XV1873-6AT10
Verification of suitability Yes • 150 m 6XV1873-6AT15
RoHS conformity • 200 m 6XV1873-6AT20
• 300 m 6XV1873-6AT30
FO FRNC cable 50/125/1 400 2)
Multimode cable, 6XV1873-2B
sold by the meter;
max. delivery unit 1 000 m;
minimum order 20 m;
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
IE FO Cords
■ Overview ■ Application
■ Function
The flexibility of the cable ensures easy installation, for example
in a control cabinet, or to connect equipment in a control room.
The length of an IE FO TP Cord is 1 m.
Cable variants with different fiber-optic connectors are used for
the easy connecting of devices to various fiber-optic interfaces.
PROFINET/Industrial Ethernet
Cabling technology
IE FO Cords
■ Technical specifications
Article No. 6XV1843-5EH10-0CC0 6XV1843-5EH10-0CB0 6XV1843-5EH10-0CA0
Product-type designation MM FO CORD SC/SC, 50/125 MM FO CORD SC/BFOC, 50/125 MM FO CORD SC/LC, 50/125
Product description Multimode glass FO cable, Multimode glass FO cable, Multimode glass FO cable,
2 Acceptability for application
pre-assembled
Cable for applications in control
pre-assembled
Cable for applications in control
pre-assembled
Cable for applications in control
cabinet cabinet cabinet
Version of the assembled FO cable pre-assembled with pre-assembled with pre-assembled with
2X SC DUPLEX connectors 1X SC DUPLEX connector and 1X SC DUPLEX connector and
1XBFOC connector 1X LC DUPLEX connector
Cable designation l-V(ZN)H 2x50/125 OM2 l-V(ZN)H 2x50/125 OM2 l-V(ZN)H 2x50/125 OM2
Cable length 1m 1m 1m
Optical data
Damping ratio per length
• at 850 nm maximum 3.5 dB/km 3.5 dB/km 3.5 dB/km
• at 1 300 nm maximum 1.5 dB/km 1.5 dB/km 1.5 dB/km
Bandwidth length product
• at 850 nm 500 kHz·m 500 kHz·m 500 kHz·m
• at 1 300 nm 1 300 kHz·m 1 300 kHz·m 1 300 kHz·m
Mechanical data
Number of fibers per FOC core 1 1 1
Number of FOC cores per FOC cable 2 2 2
Version of the FO conductor fiber Multi-mode gradient fiber 50/125 µm, Multi-mode gradient fiber 50/125 µm, Multi-mode gradient fiber 50/125 µm,
OM 2 OM 2 OM 2
Design of the FOC core fixed cores fixed cores fixed cores
Outer diameter
• of optical fibers 5 µm 5 µm 5 µm
• of the optical fiber sheath 125 µm 125 µm 125 µm
• of the FOC core sheath 2.8 mm 2.8 mm 2.8 mm
Width of the cable sheath 5.9 mm 5.9 mm 5.9 mm
Thickness of the cable sheath 2.8 mm 2.8 mm 2.8 mm
Material
• of the fiber-optic cable core Quartz glass Quartz glass Quartz glass
• of the optical fiber sheath Quartz glass Quartz glass Quartz glass
• of the FOC core sheath FR-LSZH FR-LSZH FR-LSZH
• of the fiber-optic cable sheath LSZH LSZH LSZH
• of the strain relief Aramide fibers Aramide fibers Aramide fibers
Color
• of the FOC core sheath green/green green/green green/green
Bending radius
• with single bend 42 mm 42 mm 42 mm
minimum permissible
Traction stress maximum 500 N 500 N 500 N
Continuous lateral force per length 100 N/cm 100 N/cm 100 N/cm
Weight per length 19 kg/km 19 kg/km 19 kg/km
Permitted ambient conditions
Ambient temperature
• during operating -20 … +70 °C -20 … +70 °C -20 … +70 °C
• during storage -25 … +70 °C -25 … +70 °C -25 … +70 °C
• during transport -25 … +70 °C -25 … +70 °C -25 … +70 °C
• during installation -10 … +70 °C -10 … +70 °C -10 … +70 °C
Protection class IP IP20 IP20 IP20
Burning behaviour Flame-retardant in accordance with Flame-retardant in accordance with Flame-retardant in accordance with
IEC 60332-3-22 (CatA) IEC 60332-3-22 (CatA) IEC 60332-3-22 (CatA)
PROFINET/Industrial Ethernet
Cabling technology
IE FO Cords
PROFINET/Industrial Ethernet
Cabling technology
IE FO Cords
2 Ambient temperature
• during operating -20 … +70 °C -20 … +70 °C -20 … +70 °C
• during storage -25 … +70 °C -25 … +70 °C -25 … +70 °C
• during transport -25 … +70 °C -25 … +70 °C -25 … +70 °C
• during installation -10 … +70 °C -10 … +70 °C -10 … +70 °C
Protection class IP IP20 IP20 IP20
Burning behaviour Flame-retardant in accordance with Flame-retardant in accordance with Flame-retardant in accordance with
IEC 60332-3-22 (CatA) IEC 60332-3-22 (CatA) IEC 60332-3-22 (CatA)
Product properties, functions,
components general
Product feature
• halogen-free Yes Yes Yes
• silicon-free Yes Yes Yes
Product component Rodent protection No No No
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes Yes
PROFINET/Industrial Ethernet
Cabling technology
IE FO Cords
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
■ Overview ■ Benefits
■ Application
SIMATIC NET POF and PCF fiber optic conductors are used
to construct optical indoor PROFINET and Industrial Ethernet
networks. Devices with integral optical interface (SC RJ
connection system) are, for example, SCALANCE X200-4P IRT,
SCALANCE X201-3P IRT, SCALANCE X202-2P IRT,
• Electrical isolation of PROFINET/Ethernet devices SCALANCE X101-1POF and ET 200S.
• Protection of the transmission path against electromagnetic
interference POF and PCF fiber optic cables can be assembled easily on site
with SC RJ plugs. The maximum cable length between two
• Up to 50 m cable length with plastic fiber optic cables and devices is 50 m for POF and 100 m for PCF fiber-optic cables.
up to 100 m with PCF fiber optic cables
• Rugged fiber-optic standard cables, designed for industrial
applications
• Extensive approvals (UL)
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
■ Design
Different types of POF and PCF fiber optic cables are offered:
2
outer sheath outer sheath
strain relief using support element
aramide yarn
single core sheath
ble iling C able
ndard Ca PCF Tra
POF Sta
fleece wrapping
G_IK10_XX_10179
G_IK10_XX_10031
with strain relief
strain relief elements
using aramide
POF fiber single core sheath PCF fiber
yarn
hollow core
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
■ Technical specifications
Article No. 6XV1874-2A 6XV1874-2B
Product-type designation POF Standard Cable GP POF Trailing Cable
Product description Fiber-optic cable with polyoptical fiber, sold by the meter, Fiber-optic cable with polyoptical fiber, sold by the meter,
2 Acceptability for application
unassembled
Cable for fixed installation indoors,
unassembled
Cable for moving applications (e.g. trailing cables)
UL approval
Version of the assembled FO cable can be assembled wit SC RJ or can be assembled wit SC RJ or
SC RJ Plug PRO connectors SC RJ Plug PRO connectors
Cable designation I-V4Y(ZN)Y 2P 980/1 000 I-V4Y(ZN)11Y 2P 980/1 000 FLEX UL
Optical data
Damping ratio per length at 650 nm 0.16 dB/m 0.18 dB/m
maximum
Bandwidth length product at 650 nm 1 GHz·m 1 GHz·m
Mechanical data
Number of fibers per FOC core 1 1
Number of FOC cores per FOC cable 2 2
Version of the FO conductor fiber POF FOC 980/1 000 µm POF FOC 980/1 000 µm
Outer diameter
• of optical fibers 980 µm 980 µm
• of the optical fiber sheath 1 000 µm 1 000 µm
• of the FOC core sheath 2.2 mm 2.2 mm
• of the cable 7.8 mm 8 mm
Symmetrical deviation
• of the outer diameter 0.1 mm 0.1 mm
of the FOC core sheath
Material
• of the fiber-optic cable core Polymethylmethacrylate (PMMA) Polymethylmethacrylate (PMMA)
• of the optical fiber sheath Fluoridated special polymer Fluoridated special polymer
• of the FOC core sheath PA PA
• of the fiber-optic cable sheath PVC PUR
• of the strain relief Kevlar fibers Kevlar fibers
Color
• of the FOC core sheath orange / black orange / black
• of the cable sheath green green
Bending radius
• with single bend minimum permissi- 100 mm 40 mm
ble
• with multiple bends minimum per- 150 mm 55 mm
missible
• with continuous bending - 55 mm
Number of bending cycles - 5 000 000
Number of torsion cycles in the case - 10 000
of torsion by ± 360° on 1 m cable
length
Traction stress maximum 100 N 100 N
Short-term shear force per length 100 N/cm 400 N/cm
Continuous lateral force per length - 20 N/cm
Weight per length 65 kg/km 55 kg/km
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
2 Acceptability for application Field-assembly connector for push- For connection of POF fiber-optic
pull device connection in high degree cables
For connection of PCF fiber-optic
cables
of protection
Transmission rate
Transfer rate
• 1 for Industrial Ethernet 100 Mbit/s 100 Mbit/s 100 Mbit/s
• 2 for Industrial Ethernet - - -
Interfaces
Number of electrical connections
• for Industrial Ethernet FC TP cables - - -
• for network components - - -
and terminal equipment
Design of electrical connection
• for Industrial Ethernet FC TP cables - - -
• for network components - - -
and terminal equipment
Number of optical interfaces 1 1 1
for optical waveguide
Design of optical connections SC RJ connector SC RJ connector SC RJ connector
for network components or terminal (Push Pull device connection) (Push Pull device connection) (Push Pull device connection)
devices
Design of the electrical connection No No No
FastConnect
Mechanical data
Material of the enclosure plastic plastic plastic
Design, dimensions and weight
Type of cable outlet 180 degree cable outlet 180 degree cable outlet 180 degree cable outlet
Width 22 mm 22 mm 22 mm
Height 30 mm 30 mm 30 mm
Depth 62.5 mm 62.5 mm 62.5 mm
Net weight 63.5 g 63.5 g 63.5 g
Permitted ambient conditions
Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without - - -
condensation during operating
maximum
Protection class IP IP65/67 IP65/67 IP65/67
Chemical resistance to water resistant resistant resistant
Product properties, functions,
components general
Product feature silicon-free Yes Yes Yes
Product component strain relief Yes Yes Yes
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes Yes
• UL-registration No No No
PROFINET/Industrial Ethernet
Cabling technology
POF and PCF fiber-optic cables
2
sold by the meter (1 pack = 20 items)
max. length 1 000 m,
minimum order 20 m IE SC RJ POF Plug PRO 6GK1900-0MB00-6AA0
POF Trailing Cable 980/1000 6XV1874-2B Screw connector for local assembly
on POF FOC
POF trailing cable for use in cable (1 pack = 1 unit)
carriers, with rugged PUR sheath;
sold by the meter IE SC RJ POF refill set 6GK1900-0MN00-0AA0
max. length 1 000 m, Refill set for Termination Kit SC RJ
minimum order 20 m POF Plug consisting of grinding
PCF Standard Cable GP 200/230 6XV1861-2A paper and grinding base (set of 5)
Assembly case for local assembly SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0
of SC RJ connectors, comprising a Electronic manuals for
stripping tool, Kevlar scissors, communication systems,
microscope, grinding paper and communication protocols,
grinding base and communication products;
on DVD;
German/English
■ More information
You can order components supplementary to the SIMATIC NET
cabling range from your local contact.
Technical advice on this subject is available from:
J. Hertlein
I IA SC CI PRM 4
Phone: +49 (911) 750-4465
E-mail: juergen.hertlein@siemens.com
PROFINET/Industrial Ethernet
Cabling technology
POF/PCF FOC termination kit
■ Overview ■ Design
2 outer sheath
strain relief using
aramide yarn
able
ndard C
POF Sta
G_IK10_XX_10179
POF fiber single core sheath
fleece wrapping
• Easy installation of the unassembled cables in industrial
G_IK10_XX_10031
with strain relief
plants strain relief elements
• Flexible assembly of connectors on POF and PCF fiber optic using aramide
PCF fiber
yarn
cables on site (SC RJ connectors)
hollow core
• Mistakes are prevented with easy visual inspection of the
assembled connector on site using a microscope
Cable construction PCF plastic optical fiber
• Simple repair of POF and PCF fiber optic cables in the field
The kit is available in assembly cases for on-site installation of
■ Application SC RJ connectors on PCF fiber-optic cables.
SIMATIC NET POF and PCF fiber-optic cables are used to con- It consists of a stripping tool, buffer stripping tool, Kevlar
struct optical indoor and outdoor Industrial Ethernet/PROFINET scissors, fiber breaking tool and microscope.
networks. They are easy to assemble on-site with the Termination
Kits and 2 x 2 RJ connectors. The maximum cable length be-
tween two Industrial Ethernet/PROFINET devices is 100 m for
PCF and 50 m for POF fiber-optic cables.
Industrial Ethernet/PROFINET devices with integral optical inter-
face (SC RJ connection system) are, for example, SCALANCE X-
200P IRT and ET200S.
PROFINET/Industrial Ethernet
Cabling technology
POF/PCF FOC termination kit
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Overview ■ Benefits
■ Application
The unmanaged Industrial Ethernet media converters of the
SCALANCE X-100 product line are ideally suited to the The unmanaged media converters of the SCALANCE X-100
conversion of different transmission media in Industrial Ethernet product line permit low-cost conversion of various transmission
networks at data transfer rates of 10/100 Mbit/s in line, star and media within Industrial Ethernet line, star and ring topologies.
ring topologies. They are designed for installation in the control cabinet.
• Electrical or optical connection to stations or network in Single, remote terminal units on network segments can be linked
accordance with the port type of the devices via the optical path of the SCALANCE X-100 media converters.
• Rugged metal enclosure for space-saving cubicle mounting Integration of an optical path into a redundant ring is also
on standard rails, S7-300 DIN rails, or for wall mounting possible, as well as installation of the SCALANCE X-100 media
converters into a standby link.
• Rugged, industry-standard station connections with
PROFINET-compatible RJ45 connectors that offer additional
strain relief and bending strain relief thanks to latching on the
housing
• Redundant power supply
• Diagnostics on the device by means of LEDs (power, link
status, data communication)
• Error signaling contact with easy adjustment using the SET
button
• Connection of existing 10 Mbit/s fiber-optic networks
• Connection of existing 10Base5 networks (e.g. SINEC H1)
Product versions
SCALANCE X101-1, SCALANCE X101-1LD,
SCALANCE X101-1POF, SCALANCE X101-1FL and
SCALANCE X101-1AUI
• For converting electrical signals into optical signals in Indus-
trial Ethernet line, star and ring topologies
• The Industrial Ethernet media converters have an electrical
10/100 Mbit/s RJ45 port and:
- SCALANCE X101-1
1x 100 Mbit/s BFOC port, optical (multimode, glass FOC)
- SCALANCE X101-1LD
1x 100 Mbit/s BFOC port, optical (singlemode, glass FOC)
- SCALANCE X101-1POF
1x 100 Mbit/s SC-RJ port, optical
(plastic optical fiber, POF FOC)
- SCALANCE X101-1AUI
1x 10 Mbit/s AUI interface with Sub-D connections
- SCALANCE X101-1FL
1x 10 Mbit/s BFOC port, optical (multimode, glass FOC)
• Redundant power supply with 2 x 24 V DC
• Diagnostics on the device using LEDs (power, link status, data
traffic) and signaling contact (alarm screen form can be set
using a button on the device)
• The electric RJ45 port is industry-standard and features an
additional retaining collar for connection of the
IE FC RJ45 Plugs
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Design
The SCALANCE Industrial Ethernet media converters with a The following port types are available:
rugged metal housing are optimized for mounting on a standard • 10/100BaseTX, RJ45 port:
rail and an S7-300 DIN rail. Direct wall mounting in various automatic detection of the data rate (10 or 100 Mbit/s), with
positions is also possible. Due to the housing dimensions that
2
autosensing and autocrossover function for connecting IE FC
correspond to those of the S7-300, the devices are ideally suited cables via IE FC RJ45 connectors over distances up to 100 m
for integration into an automation solution using S7-300 compo-
nents. • 100BaseFX, BFOC port with glass fiber-optic cable:
for direct connection to Industrial Ethernet glass fiber-optic
The SCALANCE X-100 media converters feature: cables up to 3000 m or 26000 m for configuring line, star or
• A 4-pole terminal block for connecting the redundant supply ring topologies
voltage (2 x 24 V DC) • 100BaseFX,SC RJ port with POF fiber-optic cable:
• A row of LEDs for displaying status information for direct connection to Industrial Ethernet POF fiber-optic
(power, link status, data communication, signaling contact) cables up to 50 m or to Industrial Ethernet PCF fiber-optic
cables up to 100 m for configuring line, star or ring topologies
• A 2-pole terminal block for connecting the floating signaling
contact • 10BaseFL, BFOC port with glass fiber-optic cable:
for direct connection to Industrial Ethernet glass fiber-optic
• A SET button for local configuration of the signaling contact cables up to 3000 m for configuring line, star or ring topol-
and of cascading mode ogies
• AUI, 15-pin Sub-D port:
for connecting an Industrial Ethernet AUI cable (connecting
cable 727-1/drop cable) of up to 50 m to AUI transceiver
(no terminal equipment)
■ Function
• Configuring electrical and optical Industrial Ethernet line, star
or ring topologies
• Uncrossed connecting cables can be used due to
Autocrossover function integrated in the TP ports
• Easy configuration and extension of the network;
no limits to network extension when switches or media
converters of the SCALANCE X-100 family are cascaded.
• Integration of existing 10Base FL and/or 10Base5 networks
SIMATIC environ-
Signaling contact
Ring redundancy
LED diagnostics
On-site display
Fast Ethernet
(SET button)
2 x 24 V DC
without RM
10 / 100 Mbit/s 10 Mbit/s 100 Mbit/s 10 Mbit/s
ment
SCALANCE X101-1 1 1 • • • • • • •
SCALANCE X101-1LD 1 1 • • • • • • •
SCALANCE X101-1POF 1 1 • • • • • • •
G_IK10_XX_10137
SCALANCE X101-1AUI 1 1 • • • • • • •
SCALANCE X101-1FL • • • • • • •
Function overview of Industrial Ethernet media converters
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Function (continued)
Network topology and network configuration
The SCALANCE X-100 media converters are typically When configuring the network, it is necessary to observe the
accommodated in one control cabinet together with the nodes following boundary conditions:
2
to be connected. They can be installed in line, star and ring • Length of the TP cable between two SCALANCE X media
topologies. converters:
- Max. 100 m with Industrial Ethernet FastConnect products
• Length of the optical cables:
- Max. 5 km with Industrial Ethernet multimode fiber-optic
cables
- Max. 26 km with Industrial Ethernet singlemode fiber-optic
cables
- Max. 100 m with Industrial Ethernet PCF fiber-optic cables
- Max. 50 m with Industrial Ethernet POF fiber-optic cables
• Length of the AUI cable:
- max. 50 m with Industrial Ethernet connecting cable 727-1
(AUI drop cable)
SCALANCE
Access Point
W788-1 M12
Field PG
G_IK10_XX_10056
ET 200S ET 200S ET 200S ET 200S ET 200S
Optical star topology with SCALANCE X101-1/X101-1LD and remote SCALANCE W Access Point
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Function (continued)
S7-400
S7-400
S7-300
2
S7-300
SCALANCE
X204-2
PC
S7-400
SCALANCE SCALANCE
X208 X208
S7-300
SCALANCE SCALANCE
X208 X208
IPC
PC
SCALANCE S7-400
IPC
X101-1 or X101-1LD
G_IK10_XX_10054
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Function (continued)
Operator Station Operator Stations
S7-300
SCALANCE SCALANCE
X204-2 X204-2
Industrial Ethernet
100 Mbit/s
Fiber-optic cable
SCALANCE XM416-4C
S7-1500 S7-1500
SCALANCE SCALANCE
X204-2 X204-2
PC
100 Mbit/s
IPC
G_IK10_XX_10047
Human machine S7-300 S7-300
interface
Optical redundant connection of two optical rings with SCALANCE X101-1 or SCALANCE X101-1LD
l{GYWWzG
wyvmpul{ plGG wvmTmvj ptGX\XTZGwuGmv
pGl
zjhshujl zjhshujl zjhshujl
YW[py{ YWYTYwGpy{ YWWT[wGpy{
l{GYWWzG
ptGX\XTZGwuGmv
nprXWXWX^]
l{GYWWzGGptGX\XTZGwuG
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Function (continued)
Diagnostics
The following information is displayed on site by LEDs:
• Power
• Port status
• Data traffic
2
zpth{pjGz^T[WW
GjwG[[ZTX The Industrial Ethernet media converters of the
SCALANCE X-100 product line can also be monitored using the
plGzGj
floating signaling contact. Two media converters of the same
pGl z type can be connected in cascading mode.
zjhshujl XWi\Tz
XW_
{
tG jGG UG
nprXWXWX^[
zjhshujl ^Y^TX
XWXTXh|p Oh|pGGP
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
■ Technical specifications
Article No. 6GK5101-1BB00-2AA3 6GK5101-1BC00-2AA3
Product-type designation SCALANCE X101-1 SCALANCE X101-1LD
Transmission rate
2 Transfer rate 1 - -
Transfer rate 2 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical connec- 2 2
tions for network components
or terminal equipment maximum
Number of electrical connections
• for network components 1 1
and terminal equipment
• for Power-over-Ethernet for network - -
components or terminal equipment
• for signaling contact 1 1
• for power supply 1 1
• for redundant power supply 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port
and terminal equipment
• for Power-over-Ethernet for network - -
components or terminal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block
• for power supply 5-pole terminal block 5-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 1 1
Design of optical interface
for optical waveguide
• at 10 Mbit/s - -
• at 100 Mbit/s BFOC-Port (Multimode up to 5 km) ST/SC-Port
Connectable optical power relative
to 1 mW
• of the receiver input maximum -14 dB 0 dB
• of the transmitter output -14 … -19 dB 0 … -5 dB
Optical sensitivity relative to 1 mW -31 dB -35 dB
of the receiver input minimum
Attenuation of fiber-optic cable trans- 0 dB 0 dB
mission link minimum necessary
Range at the optical interface 0 … 5 km 0 … 26 km
depending on the optical fiber used
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC
Supply voltage external 24 V 24 V
• minimum 18 V 18 V
• maximum 32 V 32 V
Product component fusing Yes Yes
at power supply input
Type of fusing at input 0.5 A/60 V 0.5 A/60 V
for supply voltage
Consumed current maximum 0.12 A 0.12 A
Active power loss at 24 V for DC 3W 3W
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
PROFINET/Industrial Ethernet
Industrial Ethernet switches
Overview
■ Overview
Industrial Ethernet switching components comprise SCALANCE X-400 managed (Layer 3)
• Compact Switch Modules (CSMs) For flexibly networking and structuring high-performance plant
• SCALANCE X Industrial Ethernet switches networks. Thanks to the modular design, the switches can be
• Communications processors (CP) with integral switch adapted to the respective task. Near Field Communication
(NFC) in connection with existing WLAN also enables rapid 2
Compact Switch Modules (CSMs) access to web-based management via a smartphone or tablet
connected to an available wireless network.
Unmanaged switches for use directly on the SIMATIC for
interface expansion and integration of machines into existing Optional routing functions on Layer 3 permit communication
plant networks between different IP subnets.
SCALANCE X-000/XB-000 unmanaged SCALANCE X-500 managed (Layer 3)
Unmanaged switches with electrical and/or optical ports for For networking and structuring high-performance industrial
designing small networks for machine or plant islands with networks and for connecting office networks to automation
10/100/1000 Mbit/s networks. As a Layer 3 switch, SCALANCE X-500 is extremely
well suited to use as a central component in backbone networks,
SCALANCE X-100 unmanaged e.g. when a high number of ports is required, at extremely high
Switches with electrical and/or optical ports, redundant power transmission rates (10 Gigabit Ethernet), or for redundant con-
supply, and signaling contact for use in machine-level nection to an office infrastructure. The rack switch (19" design)
applications (also available as media converter with two ports can be used flexibly to suit requirements thanks to its modular
for conversion between two different media). design and the plug-in 4-port media modules (electrical and
optical).
SCALANCE X-200 managed
Routing functions on Layer 3 permit communication between
For universal use, from machine-level applications to networked different IP subnets.
subsystems. Configuration and remote diagnosis are integrated
into the STEP 7 engineering tool. This increases the level of plant Communications processors for SIMATIC
availability. Devices with a high degree of protection facilitate with integral switch
cabinet-free construction. Managed switches for adding Industrial Ethernet/PROFINET
Corresponding switches (SCALANCE X-200IRT) are also interfaces to the SIMATIC and for integrating the controllers into
available for use in subsystem networks with hard real-time existing line or ring topologies.
requirements and maximum availability. Thanks to integral Layer 3 functionality, the Advanced-CPs can
SCALANCE XF-200 managed also be used as routers between IP subnets.
SCALANCE XF-200 Industrial Ethernet switches have the same Communications processors for PC with integral switch
functions as SCALANCE X-200 switches. The flat design in Managed switches for adding Industrial Ethernet/PROFINET
ET 200S format (IP20 protection) mean they are optimally suit- interfaces to industrial PCs and for integrating PCs into existing
able for space-saving use in small control boxes. line topologies.
SCALANCE X-300 managed
Networking of subsystem/plant areas, as well as linking to the
enterprise network. The SCALANCE X-300 managed product
line combines the firmware functionality of the SCALANCE X-400
line with the compact design of the SCALANCE X-200 line.
This means the SCALANCE X-300 switches have extended
management functions and an extended firmware functionality
compared to the SCALANCE X-200 switches.
Electrical and optical Gigabit Ethernet ports are also available.
SCALANCE XR-300 managed
The SCALANCE XR-300 Industrial Ethernet switches corre-
spond functionally to the SCALANCE X-300 switches. Designed
as rack switches, they are particularly suitable for use in 19" con-
trol cabinets. They are also fully modular, and due to their 2-port
media modules (electrical and optical) they can be adapted to
the respective task.
For use in power plants and under difficult environmental
conditions, ECC (Enhanced Environmental Conditions) versions
may be used in compact and rack designs.
PROFINET/Industrial Ethernet
Industrial Ethernet switches
Overview
■ Overview (continued)
2
Operations Level
managed
X-500 1)
CP 343-1 CP 443-1
XR-500
Advanced Advanced
managed
X-400 1)
CP 1623/
Control Level
CP 1628
XM-400
managed
X-300 1)
CP 443-1
CP 343-1 CM 1542-1
X-200 1)
CP 343-1 Lean
XF-200 X-200 X-200PRO
X-200IRT 1)
managed
Field Level
G_IK10_XX_10237
unmanaged
X-000
X005 XB-000/XB-000G
Overview of SCALANCE X Industrial Ethernet switches and components with switch functionality
PROFINET/Industrial Ethernet
Industrial Ethernet switches
Overview
■ Overview (continued)
CSM
Network component Integral switch function
• Basis for integrated networking in industrial • Configuration of small networks • Communications processor for interfacing with
automation - from the field to the management • Easy expansion of the number of ports for: PROFINET/Industrial Ethernet including
level - Connection of local HMI systems integral switch for:
• Network components optimized for various - Connection to higher-level networks - For interfacing with distributed I/O.
applications: - Service/maintenance - Connection to higher-level networks
- Small and large-scale structured networks • Space-saving design of SIMATIC - IP routing
- Management functions • Unmanaged Switch with local diagnostics - Service/maintenance
- Connection to IT networks • SIMATIC or PC module design
G_IK10_XX_10238
- Configuring of redundant networks • Functions for network diagnostics
- Use with Industrial Ethernet and PROFINET
• Robust housing for harsh environments
• Graded diagnostics concept
PC-based applications
High-volume machine
Machine building and
Plant subnetworking
plant engineering
Internal machine
Plant networking
Industry-related
and distribution
SIMATIC S7
applications
networking
building
Application areas / type of network /
requirements
High-performance backbone networks with very
X-500 high emphasis on functionality / port density / ● ● ●
availability and interface to IT network
High-performance plant network with high ● ● ●
X-400 emphasis on functionality and availability
X-300 Large networks with high emphasis on functiona- ●
lity and availability
X-300EEC/ ● ●
XR-300EEC
X-200 Networks with higher emphasis on functionality ● ●
and availability
X204RNA ● ●
X204RNA ● ● ●
EEC
X-100 Networks with low emphasis on functionality ● ●
X-000 ● ●
robustness
PROFINET/Industrial Ethernet
Industrial Ethernet switches
Overview
■ Overview (continued)
PROFINET IO Device
Time synchronization
Power-over-Ethernet
Real-Time (IRT)
Modular through
Gigabit Ethernet
2
media modules
Isochronous
according to
SIMATIC S7
IEEE 1588
19“ design
Support of
Diagnosis
Layer 3
(EEC)
Features
X-500 ● ● ● ● ● ● ● ●
X-400 ● ● ● ● ● ●
X-300 ● ● ● ● ● ● ●
X-300EEC/ ● ● ● ● ● ● ●
XR-300EEC
2)
X-200 ● ● ●
X204RNA ●
X204RNA
EEC
X-100 ●
X-000 ●1)
CSM ●
3)
CPs ● ● ● ●
● applies 1) with Gigabit version 2) with IRT version 3) SIMATIC S7 Advanced CPs only
■ More information
Selection tools:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
LOGO! CSM unmanaged
■ Overview ■ Benefits
■ Application
The LOGO! CSM is an Industrial Ethernet switch in compact,
modular design for use in devices of the new LOGO! generation
with Industrial Ethernet connection. With the LOGO! CSM, the
Ethernet interface of the SIMATIC LOGO! can be multiplied to
enable simultaneous communication with control and program-
ming devices, other controllers, or the office world.
The module is used to connect a LOGO! and up to three other
nodes to an Industrial Ethernet network with 10/100 Mbit/s in an Problem-free external access (for diagnostics purposes, for ex-
electrical linear, tree or star topology. ample) is possible via the four Ethernet ports.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
LOGO! CSM unmanaged
■ Function ■ Integration
• Multiplication of the Ethernet interfaces for logic modules of
the product range LOGO! with Ethernet connection (…-0BA7) LOGO!
• Design of a small, local Industrial Ethernet network with three TD
further nodes
2 • Automatic detection of data transfer rate by means of Industrial Ethernet
autosensing and autocrossover functions
• LEDs for diagnostics and for status display
G_IK10_XX_10375
LOGO!
Network topology and network configuration CSM
■ Technical specifications
Article No. 6GK7177-1FA10-0AA0 6GK7177-1MA10-0AA0
Product-type designation LOGO! CSM 230 LOGO! CSM 12/24
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s
Transfer rate 2 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical connec- 4 4
tions for network components
or terminal equipment maximum
Number of electrical connections
• for network components 4 4
• and terminal equipment
• for power supply 1 1
Design of electrical connection
• for network components RJ45 port / 1 connection on front of module RJ45 port / 1 connection on front of module
and terminal equipment
• for power supply 3-pole terminal block 3-pole terminal block
Supply voltage,
current consumption, power loss
Type of supply voltage AC/DC 115 ... 240 V DC 12/24 V
Supply voltage external 230 V 24 V
• minimum 100 V 10.2 V
• maximum 240 V 30.2 V
Product component fusing Yes Yes
at power supply input
Consumed current maximum 0.02 A 0.15 A
Active power loss at 24 V for DC - 1.5 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
LOGO! CSM unmanaged
■ More information
Selection tools: SIMATIC NET Selection Tool:
To assist in selecting the right Industrial Ethernet switches • Online version:
as well as configuration of modular variants, the SIMATIC NET http://www.siemens.com/snst
Selection Tool and the TIA Selection Tool are available at: • Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 1277 unmanaged
■ Overview ■ Design
The CSM 1277 compact switch module offers all advantages
of the SIMATIC S7-1200 design:
• Compact design;
2
the rugged plastic enclosure contains:
- 4 x RJ45 ports for connecting to Industrial Ethernet
- 3-pole plug-in terminal strip for connection of the external
24 V DC supply on the top
- LEDs for diagnostics and for status display of the Industrial
Ethernet ports
• Simple mounting on the mounting rail of the S7-1200
• Fanless and consequently low-maintenance design
• The module can be replaced without using a programming
device
■ Function
• Multiplication of Ethernet interfaces of the SIMATIC S7-1200
• Design of a small, local Industrial Ethernet network with three
further nodes
• Unmanaged switch for connecting a SIMATIC S7-1200 to an
Industrial Ethernet network with a line, tree or star topology • Automatic detection of data transfer rate by means of
autosensing and autocrossover functions
• Multiplication of Ethernet interfaces on a SIMATIC S7-1200 for
additional connection of up to three programming devices, • LEDs for diagnostics and for status display
operator controls, and further Ethernet nodes
Network topology and network configuration
• Simple, space-saving mounting on the SIMATIC S7-1200
mounting rail Various network topologies can be implemented using the
CSM 1277 compact switch module:
• Low-cost solution for implementing small, local Ethernet
networks • Connection of SIMATIC S7-1200 in linear topology:
at least one RJ45 connection of the SIMATIC S7-1200 remains
• Connection without any problems using RJ45 standard vacant, e.g. for connecting a programming device (PG)
connectors
• Connection of SIMATIC S7-1200 to a higher-level network in a
• Simple and fast status display via LEDs on the device tree/star topology:
• Integral autocrossover function permits use of uncrossed at least two RJ45 connections of the SIMATIC S7-1200 remain
connecting cables vacant, e.g. for connecting a programming device/operator
panel (PG/OP)
■ Benefits • Design of a small, local network with a SIMATIC S7-1200 and
three further Ethernet nodes
Configuration
The CSM 1277 compact switch module is an unmanaged switch
• Reduction in assembly costs and mounting space compared and need not be configured.
to use of external network components Diagnostics
• Fast commissioning, as no configuration is necessary
The following information is displayed on LEDs on the device:
• Flexible expansion of the network by simply inserting the CSM
• Power
Field PG
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 1277 unmanaged
■ Technical specifications
Article No. 6GK7277-1AA10-0AA0 Article No. 6GK7277-1AA10-0AA0
Product-type designation CSM 1277 Product-type designation CSM 1277
Transmission rate Design, dimensions and weight
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
Design SIMATIC S7-1200 device design 2
Width 45 mm
Interfaces Height 100 mm
Number of electrical/optical connec- 4 Depth 75 mm
tions for network components Net weight 0.15 kg
or terminal equipment maximum
Mounting type
Number of electrical connections • 35 mm DIN rail mounting Yes
• for network components 4 • wall mounting Yes
and terminal equipment
• S7-300 rail mounting No
• for power supply 1
Product functions management,
Design of electrical connection configuration
• for network components RJ45 port
and terminal equipment Product function switch-managed No
• for power supply 3-pole terminal block Standards, specifications,
Supply voltage, approvals
current consumption, power loss Standard
Type of supply voltage DC • for EMC from FM FM3611: Class 1, Division 2,
Group A, B, C, D / T.., CL.1, Zone 2,
Supply voltage external 24 V GP. IIC, T.. Ta
• minimum 19.2 V • for hazardous zone EN 600079-15:2005,
• maximum 28.8 V EN 600079-0:2006, II 3 G Ex nA II T4,
KEMA 08 ATEX 0003 X
Product component fusing Yes
at power supply input • for safety of CSA and UL UL 508, CSA C22.2 No. 142
• for emitted interference EN 61000-6-4 (Class A)
Type of fusing at input 0.5 A / 60 V • for interference immunity EN 61000-6-2
for supply voltage
Verification of suitability EN 61000-6-2, EN 61000-6-4
Consumed current maximum 0.07 A
• CE mark Yes
Active power loss at 24 V for DC 1.6 W • C-Tick Yes
Permitted ambient conditions • KC approval No
Ambient temperature
• during operating 0 … 60 °C
• during storage -40 … +70 °C
• during transport -40 … +70 °C
Relative humidity at 25 °C without 95 %
condensation during operating
maximum
Protection class IP IP20
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 1277 unmanaged
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 377 unmanaged
■ Overview ■ Application
• For the economical construction of small, electrical Industrial
Ethernets with star, tree and linear structures using a SIMATIC
S7-300 or ET 200M
■ Design 2
The compact switch module CSM 377 features all the advan-
tages of the SIMATIC S7-300 design:
• Compact construction;
the rugged plastic enclosure features the following on the front
panel:
- 4 x RJ45 ports for the connection to Industrial Ethernet
(retaining collar)
- 1 x 2-pin pluggable terminal strip for the connection of the
external 24 VDC power supply
- LEDs for diagnostics and for status display of the Industrial
Ethernet ports
• 10/100BaseTX;
automatic detection of the data rate with autosensing and
autocrossover function for the connection of IE FC cables by
• Unmanaged switch for the connection of a SIMATIC S7-300
means of IE FC RJ45 Plug 180 up to 100 m
with integral PROFINET interface or with an Industrial Ethernet
CP or ET 200M to an Industrial Ethernet in an electrical linear, • Simple mounting;
tree or star structure the CSM 377 switch module is mounted on the mounting rail
of the S7-300. As it has no connection to the backplane bus of
• As many as three additional nodes can be connected
the S7-300 or ET 200M, it must either be inserted at the
• As an unmanaged switch, the CSM 377 is used for integrating beginning (first module to the left of the CPU) or at the end
small machines into existing automation networks or for the (last module on far right) of the S7-300 station. The connection
standalone operation of the machines to the CPU of the S7-300 is either by means of an Industrial
• Simple, space-saving attachment to S7-300 mounting rail due Ethernet cable or an Industrial Ethernet twisted pair cord.
to design as single-width module in S7-300 format • Three further Industrial Ethernet interfaces (TP ports) are
• Low-cost solution for implementing small, local Ethernet available for the connection of additional Ethernet nodes such
networks as HMI panels or ET 200
• Rugged, industry-standard node connections with PROFINET- • The CSM 377 can be operated without a fan and no backup
compliant RJ45 connectors that latch onto the enclosure to battery is necessary
offer additional strain and bending relief • The module can be replaced without a programming device
■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 377 unmanaged
■ Function
• Connection of a SIMATIC S7-300 to a higher-level electrical
network in a linear, tree or point-to-point structure HMI station
e.g. WinCC flexible
• Construction of a small local network with one SIMATIC S7-300
and three other Ethernet nodes
2 Thanks to the switching technology used, the CSM 377 is
S7-300 with
CP 343-1 Advanced
suitable for use in PROFINET networks, but offers no additional and CSM 377
PROFINET functions, i.e. no integration into the PROFINET
diagnostics. PROFINET
G_IK10_XX_10224
S7-300 with Industrial PC
CSM 377 and with CP 1613 A2/
CP 343-1 CP 1623
Diagnostics
PROFINET
The following information is indicated on the device by means
Industrial Ethernet of LEDs:
• Power
Connection of SIMATIC S7-300 with CSM 377 to Industrial Ethernet • Port status
with linear structure
• Data traffic
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 377 unmanaged
■ Technical specifications
Article No. 6GK7377-1AA00-0AA0 Article No. 6GK7377-1AA00-0AA0
Product-type designation CSM 377 Product-type designation CSM 377
Transmission rate Design, dimensions and weight
Transfer rate 1 10 Mbit/s Design SIMATIC S7-300 device design 2
Transfer rate 2 100 Mbit/s Width 40 mm
Interfaces Height 125 mm
Depth 118 mm
Number of electrical/optical connec- 4
tions for network components Net weight 0.2 kg
or terminal equipment maximum Mounting type
Number of electrical connections • 35 mm DIN rail mounting No
• for network components 4 • wall mounting No
and terminal equipment • S7-300 rail mounting Yes
• for power supply 1
Product functions management,
Design of electrical connection configuration
• for network components RJ45 port Product function switch-managed No
and terminal equipment
• for power supply 2-pole terminal block Standards, specifications,
approvals
Supply voltage,
current consumption, power loss Standard
• for EMC from FM FM3611: Class 1, Division 2,
Type of supply voltage DC Group A, B, C, D / T.., CL.1, Zone 2,
Supply voltage external 24 V GP. IIC, T.. Ta
• minimum 19.2 V • for hazardous zone EN 60079-15, II 3 G Ex nA II T..,
• maximum 28.8 V KEMA 06 ATEX 0021 X
• for safety of CSA and UL UL 508, CSA C22.2 No. 142
Product component fusing Yes • for hazardous area of CSA and UL UL 1604 and UL 2279-15
at power supply input (Hazardous Location)
Type of fusing at input 0.5 A / 60 V • for emitted interference EN 61000-6-4:2001
for supply voltage • for interference immunity EN 61000-6-2:2001
Consumed current maximum 0.07 A Verification of suitability EN 61000-6-2:2001,
Active power loss at 24 V for DC 1.6 W EN 61000-6-4:2001
• CE mark Yes
Permitted ambient conditions • C-Tick Yes
Ambient temperature • KC approval No
• during operating 0 … 60 °C
• during storage -40 … +70 °C
• during transport -40 … +70 °C
Relative humidity at 25 °C without 95 %
condensation during operating
maximum
Protection class IP IP20
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Compact switch modules
CSM 377 unmanaged
■ Overview
XB008
XB005
● applies
XB008G
XB005G
XB004-1
XB004-1G
XB004-1LD
XB004-1LDG
Type of device
X005 / X005TS
Connection to S7 backplane bus
Format module S7
Hardware
PC module
●
●
●
●
●
●
●
●
Box type of construction
Modular design
© Siemens AG 2014
10 Gigabit Ethernet
●
●
●
●
Gigabit Ethernet
●
●
●
●
●
LED diagnosis
●
SIMATIC environment
Signal contact
Siemens IK PI · 2015
Local display (SET pushbutton)
C-PLUG slot
G_IK10_XX_10317
2/161
SCALANCE X-000 unmanaged
Industrial Ethernet Switches
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X005 unmanaged
■ Overview ■ Benefits
■ Application
• For low-cost configuration of small, electrical Industrial
The unmanaged Industrial Ethernet Switch SCALANCE X005 is Ethernet star and line topologies with switching functionality,
optimized for low-cost installation of small Industrial Ethernet e.g. machine or plant islands
networks with data transfer rates of 10/100 Mbit/s in a line and • For use in the control cabinet
star topology.
• The SCALANCE X005TS (Transportation Systems) is suitable
• Five electrical nodes or network connections for use in rail and road transport due to its specification
• Rugged metal enclosure for space-saving cubicle mounting according to EN 50155 and e1/E1
on standard rails, S7-300 DIN rails, or for wall mounting
• Rugged, industry-standard station connections with ■ Design
PROFINET-compatible RJ45 connectors that offer additional
strain relief and bending strain relief thanks to latching on the The SCALANCE Industrial Ethernet switches with a rugged
housing metal housing (IP30) are optimized for mounting on a standard
rail and an S7-300 DIN rail. Direct wall mounting in different
• Diagnostics on the device by means of LEDs
positions is also possible. Due to the housing dimensions that
(power, link status, data communication)
correspond to those of the SIMATIC S7-300, the devices are very
Product versions well suited for integration into an automation solution using
S7-300 components.
• SCALANCE X005
for setting up electrical star and linear topologies with five The SCALANCE X005 switch is equipped with:
electrical ports • Supply voltage 1 x 24 V DC
• SCALANCE X005TS • A row of LEDs for displaying status information (power, link
for setting up electrical star and linear topologies with five status, data communication)
electrical ports for use in rail and road transport with extended
temperature range • 5 x 10/100BaseTX, RJ45 ports:
automatic detection of the data rate (10 or 100 Mbit/s),
with autosensing and autocrossover function for connecting
IE FC cables via IE FC RJ45 Plug 180 over distances
up to 100 m
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X005 unmanaged
■ Function
• Uncrossed connecting cables can be used due to
Autocrossover function integrated in the ports PC with
CP 1613 A2/
• Network load disconnection through integral switch
CP 1623
functionality
Network topology and network configuration 2
SCALANCE
The SCALANCE X005 is typically accommodated in one control X005
cubicle together with the nodes to be connected. It can be S7-200 with CP 243-1
operated in small electrical star and line topologies. Network
configuration and expansion are easy to implement; there are no
limitations with the cascading of SCALANCE X005.
When configuring the network, it is necessary to observe the S7-1200 with
following boundary conditions: CSM 1277
• Length of the TP cable between two SCALANCE X switches:
- Max. 100 m with Industrial Ethernet FastConnect products
G_IK10_XX_30039
Diagnostics
The following information is displayed on site by LEDs: IPC with
• Port status CP 1613 A2/ Panel PC
CP 1623
• Data traffic
Star-shaped network topology with SCALANCE X005
wjG wjGG
jwGX]XZGhYV jwGX]XZGhYV
jwGX]YZ jwGX]YZ
wGwj
z^TYWW z^TYWW
jwGY[ZTX jwGY[ZTX
z^TZWW
jwGZ[ZTX
pwjG pwjG
jwGX]XZGhYV jwGX]XZGhYV
jwGX]YZ jwGX]YZ
nprXWZWW[W
pGl
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X005 unmanaged
■ Technical specifications
Article No. 6GK5005-0BA00-1AA3 6GK5005-0BA00-1CA3
Product-type designation SCALANCE X005 SCALANCE X005TS
Transmission rate
2 Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
Interfaces
Number of electrical/optical connec- 5 5
tions for network components
or terminal equipment maximum
Number of electrical connections
• for network components 5 5
• and terminal equipment
• for power supply 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port
and terminal equipment
• for power supply 2-pole terminal block 2-pole terminal block
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC
Supply voltage external 24 V 24 V
• minimum 18 V 18 V
• maximum 32 V 32 V
Product component fusing at power Yes Yes
supply input
Type of fusing at input for supply volt- 0.5 A / 60 V 0.5 A / 60 V
age
Consumed current maximum 0.08 A 0.08 A
Active power loss at 24 V for DC 2W 2W
Permitted ambient conditions
Ambient temperature
• during operating 0 … 65 °C -40 … +75 °C
• during storage -40 … +80 °C -40 … +80 °C
• during transport -40 … +80 °C -40 … +80 °C
Relative humidity at 25 °C without 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) - Conformal coating, no
operation mode
Protection class IP IP20 IP30
Design, dimensions and weight
Design compact compact
Width 40 mm 40 mm
Height 125 mm 125 mm
Depth 124 mm 124 mm
Net weight 0.55 kg 0.55 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes
• wall mounting Yes Yes
• S7-300 rail mounting Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X005 unmanaged
■ More information
Selection tools: SIMATIC NET Selection Tool:
To assist in selecting the right Industrial Ethernet switches • Online version:
as well as configuration of modular variants, the SIMATIC NET http://www.siemens.com/snst
Selection Tool and the TIA Selection Tool are available at: • Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
■ Overview ■ Benefits
■ Application
The unmanaged Industrial Ethernet switches of the
SCALANCE XB-000 line allow cost-effective solutions for setting
The unmanaged Industrial Ethernet switches of the up small, electrical/optical star or line topologies with switching
SCALANCE XB-000 line are optimized for installing Industrial functionality in machines or plant units.
Ethernet networks in a line and star topology.
The enclosure is designed for space-saving installation in a
• Enclosure for space-saving installation in control cabinets or control cabinet on a standard rail.
boxes on a standard mounting rail
Product versions
SCALANCE XB005 and SCALANCE XB008
• 5 or 8 x 10/100 Mbit/s RJ45 ports, electrical
SCALANCE XB005G and SCALANCE XB008G (Gigabit)
• 5 or 8 x 10/100/1 000 Mbit/s RJ45 ports, electrical
SCALANCE XB004-1
• 4 x 10/100 Mbit/s RJ45 ports, electrical
• 1 x 100 Mbit/s SC port, optical (multi-mode, glass),
up to 5 km
SCALANCE XB004-1LD (Long Distance)
• 4 x 10/100 Mbit/s RJ45 ports, electrical
• 1 x 100 Mbit/s SC port, optical (single-mode, glass),
up to 26 km
SCALANCE XB004-1G (Gigabit)
• 4 x 10/100/1 000 Mbit/s RJ45 ports, electrical
• 1 x 1000 Mbit/s SC port, optical (multi-mode, glass),
up to 750 m
SCALANCE XB004-1LDG (Long Distance)
• 4 x 10/100/1000 Mbit/s RJ45 ports, electrical
• 1 x 1 000 Mbit/s SC port, optical (single-mode, glass),
up to 10 km
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
■ Design ■ Function
The SCALANCE XB-000 Industrial Ethernet switches are • Construction of electrical Industrial Ethernet line or star
optimized for installation on a standard rail. Wall mounting is topologies
possible. • Automatic data transmission rate detection
(10/100/1 000 Mbit/s), with autosensing and autocrossover
The SCALANCE XB-000 switches have:
• A 3-pole terminal block for connecting the power supply
function 2
(1 x 24 V DC) and functional ground • Easy network configuration and network expansion;
no limitation on network expansion with cascading of the
• An LED for indicating the status information (power) switches
• LEDs for indicating the status information (link status and data
exchange) per port Network topology and network configuration
The following port types are available: The SCALANCE XB-000 switches are typically installed with the
stations to be connected in a control cabinet or control box.
• 10/100 BaseTX electrical RJ45 ports or 10/100/1 000 BaseTX
electrical RJ45 ports: When configuring the network, it is necessary to observe the
automatic data transmission rate detection (10 or 100 Mbit/s), following boundary conditions:
with Autosensing and Autocrossing function for connecting IE • Length of the TP cable between two SCALANCE XB-000
TP cables up to 100 m. switches:
• 100 BaseFX, optical SC port: - max. 100 m
for direct connection to Industrial Ethernet FO cables. - max. 10 m via patch cables with TP Cord
Multimode fiber-optic cable up to 5 km - max. 100 m via Industrial Ethernet FC Outlet RJ45,
IE FC Standard Cable and TP Cord
• 100 BaseFX, optical SC port:
for direct connection to Industrial Ethernet FO cables. • Length of the fiber-optic cables:
Single mode fiber-optic cable up to 26 km - max. 5 km with Industrial Ethernet FO cables Multimode
- max. 26 km with Industrial Ethernet FO cables Single mode
• 1000 BaseSX, optical SC port:
for direct connection to Industrial Ethernet FO cables.
Multimode fiber-optic cable up to 750 m PC Operator control
and process
• 1000 BaseLX, optical SC port: monitoring
for direct connection to Industrial Ethernet FO cables.
Single mode fiber-optic cable up to 10 km
All connections for data cables are located at the front, and the
connection for the power supply is at the bottom.
nprXWXWY]W
SCALANCE
XB005
PLC Field devices
Industrial Ethernet
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
■ Function (continued)
SCALANCE
X308-2
1000 Mbit/s
2 PC PC with
CP 1623
Operator control
Laptop and process
monitoring SCALANCE 1000 Mbit/s
XB005G
SCALANCE SCALANCE 1000 Mbit/s
XB005 XB008
Code IP camera
reader
PLC MV420
MV440
Field devices
nprXWXWY]Y
G_IK10_XX_10259
Conveyor belt
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
Electrical line topology with SCALANCE XB005 and XB008, Electrical star topology with SCALANCE XB005G and
or SCALANCE XB005G and XB008G connection to a Gigabit Ethernet ring
Diagnostics
The following information is displayed by LEDs on site:
PC Operator control
and process • Power
monitoring • Port status
• Data traffic
Laptop
SCALANCE SCALANCE
XB004-1 XB004-1
PLC
Field devices
nprXWXWY\_
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
■ Technical specifications
Article No. 6GK5004-1BD00-1AB2 6GK5004-1BF00-1AB2 6GK5005-0BA00-1AB2 6GK5008-0BA00-1AB2
Product-type designation SCALANCE XB004-1 SCALANCE XB004-1LD SCALANCE XB005 SCALANCE XB008
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Interfaces
Number of electrical/optical connec- 5 5 5 8
tions for network components
or terminal equipment maximum
Number of electrical connections
• for network components 4 4 5 8
• and terminal equipment
• for power supply 1 1 1 1
Design of electrical connection
• for network components and RJ45 port RJ45 port RJ45 port RJ45 port
terminal equipment
• for power supply 3-pole terminal block 3-pole terminal block 3-pole terminal block 3-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 1 1 - -
Design of optical interface
for optical waveguide
• at 100 Mbit/s SC port SC port - -
(multimode up to 5 km) (singlemode up to 26 km)
Connectable optical power
relative to 1 mW
• of the transmitter output -19 … -14 dB -5 … +0 dB -- --
• of the receiver input maximum -14 dB 0 dB - -
Optical sensitivity relative to 1 mW of -32 dB -34 dB - -
the receiver input minimum
Attenuation of fiber-optic cable trans- 0 dB 0 dB - -
mission link minimum necessary
Range at the optical interface 0 … 5 km 0 … 26 km -- --
depending on the optical fiber used
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC DC
Supply voltage external 24 V 24 V 24 V 24 V
• minimum 19.2 V 19.2 V 19.2 V 19.2 V
• maximum 28.8 V 28.8 V 28.8 V 28.8 V
Product component fusing at power Yes Yes Yes Yes
supply input
Type of fusing at input for supply 0.6 A / 60 V 0.6 A / 60 V 0.6 A / 60 V 0.6 A / 60 V
voltage
Consumed current maximum 0.11 A 0.1 A 0.07 A 0.12 A
Active power loss at 24 V for DC 2.64 W 2.4 W 1.68 W 2.88 W
Permitted ambient conditions
Ambient temperature
• during operating -10 … +60 °C -10 … +60 °C -10 … +60 °C -10 … +60 °C
• during storage -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
• during transport -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP20 IP20 IP20 IP20
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
■ Overview
X116
X124
X108
X112-2
X106-1
X104-2
● applies
X108PoE
Type of device
Connection to S7 backplane bus
Format module S7
Hardware
PC module
●
●
●
●
●
●
●
Rugged, compact housing
Modular design
© Siemens AG 2014
10 Gigabit Ethernet
Gigabit Ethernet
●
LED diagnosis
●
●
●
●
●
●
SIMATIC environment
●
●
●
●
●
●
●
Signal contact
Siemens IK PI · 2015
●
●
●
●
●
●
●
C-PLUG slot
G_IK10_XX_10316
2/173
SCALANCE X-100 unmanaged
Industrial Ethernet Switches
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
SCALANCE X108 / SCALANCE X108PoE /
■ Overview SCALANCE X116 / SCALANCE X124
• Construction of electrical Industrial Ethernet star and line
topologies
- SCALANCE X108
with eight electrical ports
2 - SCALANCE X108PoE
with eight electrical ports, two of which have Power-over-
Ethernet functionality
- SCALANCE X116
with 16 electrical ports
- SCALANCE X124
with 24 electrical ports
• Diagnostics on the device using LEDs (power, link status, data
traffic) and signaling contact (alarm screen form can be set
using a button on the device)
• The RJ45 ports are suitable for industrial use and have
additional retaining collars: optimized for connecting the
IE FC RJ45 Plug 180
■ Benefits
The unmanaged Industrial Ethernet switches of the
SCALANCE X-100 product line are optimized for installing
Industrial Ethernet networks at transmission rates of
10/100 Mbit/s in a line and star topology.
• Depending on the port type of the devices, the connection • Ideal solution for configuring Industrial Ethernet line and star
to a station or network is electrical or optical with Power-over- topologies
Ethernet (PoE) functionality according to IEEE 802.3at Type 1
(corresponds to IEEE 802.3af) • Reduction of network installation costs by transmitting data
and energy (Power-over-Ethernet) via the conventional 4-core
• Rugged metal enclosure for space-saving cubicle mounting Industrial Ethernet cable (only SCALANCE X108PoE)
on standard rails, S7-300 DIN rails, or for wall mounting
• Additional power supply units can be omitted thanks to
• Rugged, industry-standard station connections with generating the Power-over-Ethernet voltage (48 V DC) direct
PROFINET-compatible RJ45 connectors that offer additional at the switch (SCALANCE X108PoE only)
strain relief and bending strain relief thanks to latching on the
housing • Space-saving installation in the cabinet thanks to the compact
design in S7-300 format
• Redundant power supply
• Reliable plug-in connection thanks to industry-standard
• Diagnostics on the device by means of LEDs device connection in conjunction with PROFINET-compliant
(power, link status, data communication) FastConnect connectors
• Error signaling contact with easy adjustment using the SET • Installation is possible without a patch field by means of
button IE FC RJ45 Plug 180 and IE FC Standard Cable
Product versions • Use of uncrossed connection cables possible by means of
integrated autocrossover function
SCALANCE X104-2 / SCALANCE X106-1 /
SCALANCE X112-2
• Construction of optical Industrial Ethernet line or star ■ Application
topologies: The switches of the SCALANCE X-100 product line support
- SCALANCE X104-2; the inexpensive construction of Industrial Ethernet line or star
with 4 electrical ports and 2 optical ports topologies with switching functions. They are designed for
- SCALANCE X106-1; installation in the control cabinet.
with 6 electrical ports and 1 optical port
- SCALANCE X112-2;
with 12 electrical ports and 2 optical ports
• Diagnostics on the device using LEDs (power, link status, data
traffic) and signaling contact (alarm screen form can be set
using a button on the device)
• The RJ45 ports are suitable for industrial use and have
additional retaining collars: optimized for connecting the
IE FC RJ45 Plug 180
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
■ Design ■ Function
The SCALANCE Industrial Ethernet switches with a rugged • Construction of electrical and optical Industrial Ethernet line or
metal housing are optimized for mounting on a standard rail and star topologies
an S7-300 rail. Direct wall mounting in various positions is also • Use of uncrossed connecting leads is possible due to
possible. Due to the dimensions of the housing that conform to integrated auto-crossover function of the ports
those of SIMATIC S7-300, the devices are optimized for integra-
tion in an automation solution with S7-300 components.
• Power supply of Power-over-Ethernet-capable terminal 2
equipment via the data line for SCALANCE X108PoE
The SCALANCE X-100 switches have: • Isolation of the load due to integrated switch functions
• A 4-pole terminal block for connecting the redundant supply • Easy network configuration and network expansion;
voltage (2 x 24 V DC) no limitation of the expansion of the network when switches of
• A row of LEDs for displaying status information the SCALANCE X-100 product line are cascaded
(power, link status, data communication, signaling contact) Network topology and network configuration
• A 2-pole terminal block for connecting the floating signaling
contact The SCALANCE X-100 switches are typically installed with the
stations to be connected in a control cabinet. They can be mixed
• A SET button for on-site configuration of the signaling contact electrically and optically in star and line topologies.
The following port types are available: When configuring the network, it is necessary to observe the
• 10/100BaseTX, RJ45 port; following boundary conditions:
automatic detection of the transmission rate • Length of the TP cable between SCALANCE X switches:
(10 or 100 Mbit/s), with autosensing and autocrossover - Max. 100 m with Industrial Ethernet FastConnect products
functions for connecting IE FC cables using
IE FC RJ45 Plug 180 up to 100 m • Length of the TP cable between SCALANCE X switch and
Power-over-Ethernet terminal equipment:
• 10/100BaseTX, RJ45 ports and - Max. 100 m with Industrial Ethernet FastConnect products
Power-over-Ethernet functionality;
automatic detection of the transmission rate • Length of the fiber-optic cables:
(10 or 100 Mbit/s), with autosensing and autocrossover - Max. 5 km with Industrial Ethernet glass fiber-optic cables
functions for connecting IE FC cables using
IE FC RJ45 Plug 180 up to 100 m and integrated Power-over-
Ethernet functionality according to IEEE 802.3at Type 1
• 100BaseFX, BFOC port;
for direct connection to the Industrial Ethernet glass FOC
up to 5 km
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
■ Function (continued)
j
z^T[WWG pwjG
2 jwG[[ZTXGh jwGX]XZGhYV
jwGX]YZ
z^TZWWG twGZ^W
jwGZ[ZTX
pGlGmjGjGYY
z
zjhshujlGXY[
plGmj
v
yq[\
plG{wGj
XWVXWWGtV
zpth{pjGmGwn
nprXWXWYW\
z^T[WWGG z^TZWWGG twGZ^W pwjG
jwG[[ZTX jwGZ[ZTX jwGX]XZGhYV
jwGX]YZ
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
■ Function (continued)
10/100 Mbit/s
X112-2 X104-2 X106-1
PROFINET
Industrial
Ethernet
G_IK10_XX_10261
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
Electrical and optical line topology with SCALANCE X112-2, X104-2 and X106-1 as well as connection
and supply of data terminals with Power-over-Ethernet (PoE) by SCALANCE X108PoE
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
■ Function (continued)
SCALANCE X414-3E
PROFINET
Industrial
Ethernet
G_IK10_XX_10206
ET 200S ET 200S ET 200S ET 200S
Diagnostics
The following information is displayed by LEDs on site:
• Power
• Port status
• Data traffic
The Industrial Ethernet switches of the SCALANCE X-100 line
can also be monitored over the floating signaling contact.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
■ Technical specifications
Article No. 6GK5104-2BB00-2AA3 6GK5106-1BB00-2AA3 6GK5108-0BA00-2AA3 6GK5108-0PA00-2AA3
Product-type designation SCALANCE X104-2 SCALANCE X106-1 SCALANCE X108 SCALANCE X108PoE
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 10 Mbit/s 2
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical connec- 6 7 8 8
tions for network components
or terminal equipment maximum
Number of electrical connections
• for network components 4 6 8 6
and terminal equipment
• for Power-over-Ethernet - - - 2
for network components
or terminal equipment
• for signaling contact 1 1 1 1
• for power supply 1 1 1 1
• for redundant power supply 1 1 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port RJ45 port
and terminal equipment
• for Power-over-Ethernet - - - RJ45 port
for network components
or terminal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 2 1 - -
Design of optical interface
for optical waveguide
• at 100 Mbit/s BFOC sockets (multimode BFOC sockets (multimode - -
up to 5 km) up to 5 km)
Connectable optical power
relative to 1 mW
• of the transmitter output -19 … -14 dB -19 … -14 dB - -
• of the receiver input maximum -14 dB -14 dB - -
Optical sensitivity relative to 1 mW -32 dB -32 dB - -
of the receiver input minimum
Attenuation of fiber-optic cable 0 dB 0 dB - -
transmission link minimum necessary
Range at the optical interface 0 … 5 km 0 … 5 km - -
depending on the optical fiber used
Signal-Inputs/outputs
Operating voltage of signaling con- 24 V 24 V 24 V 24 V
tacts at DC rated value
Operating current of signaling con- 0.1 A 0.1 A 0.1 A 0.1 A
tacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC DC
Supply voltage external 24 V 24 V 24 V 24 V
• minimum 18 V 18 V 18 V 18 V
• maximum 32 V 32 V 32 V 32 V
Product component fusing at power Yes Yes Yes Yes
supply input
Type of fusing at input for supply volt- 0.6 A / 60 V 0.6 A / 60 V 0.6 A / 60 V 4 A / 125 V
age
Consumed current maximum 0.16 A 0.15 A 0.14 A 1.7 A
Active power loss at 24 V for DC 3.8 W 3.6 W 3.36 W 10 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
2 Ambient temperature
• during operating -10 … +60 °C -10 … +60 °C -20 … +70 °C -20 … +60 °C
• during storage -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
• during transport -40 … +80 °C -40 … +80 °C -40 … +80 °C -40 … +80 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating maxi-
mum
Protection class IP IP30 IP30 IP30 IP30
Design, dimensions and weight
Design compact compact compact compact
Width 60 mm 60 mm 60 mm 60 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 124 mm 124 mm 124 mm 124 mm
Net weight 0.78 kg 0.78 kg 0.78 kg 0.9 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Mounting type - - - -
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T.., Group A, B, C, D / T.., Group A, B, C, D / T.., Group A, B, C, D / T..,
Class 1, Zone 2, Class 1, Zone 2, Class 1, Zone 2, Class 1, Zone 2,
Group IIC, T.. Group IIC, T.. Group IIC, T.. Group IIC, T..
• for hazardous zone EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA IIT.., KEMA 07 nA IIT.., KEMA 07 nA IIT.., KEMA 07 nA IIT.., KEMA 07
ATEX 0145 X ATEX 0145 X ATEX 0145 X ATEX 0145 X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), (Hazardous Location), (Hazardous Location), (Hazardous Location),
Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group
A, B, C, D / T.., Class 1 / A, B, C, D / T.., Class 1 / A, B, C, D / T.., Class 1 / A, B, C, D / T.., Class 1 /
Zone 2 / Group IIC / T.. Zone 2 / Group IIC / T.. Zone 2 / Group IIC / T.. Zone 2 / Group IIC / T..
• for emitted interference EN 61000-6-4 (Class A) EN 61000-6-4 (Class A) EN 61000-6-4 (Class A) EN 61000-6-4:2001
• for interference immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2:2001
Verification of suitability EN 61000-6-2, EN 61000-6-2, EN 61000-6-2, EN 61000-6-2:2001,
EN 61000-6-4 EN 61000-6-4 EN 61000-6-4 EN 61000-6-4:2001
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
Marine classification association
• American Bureau Yes Yes Yes No
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes Yes No
• Det Norske Veritas (DNV) Yes Yes Yes No
• Germanische Lloyd (GL) Yes Yes Yes No
• Lloyds Register of Shipping (LRS) Yes Yes Yes No
• Nippon Kaiji Kyokai (NK) Yes Yes Yes No
• Polski Rejestr Statkow (PRS) Yes Yes Yes No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
2
for 10/100 Mbit/s, routing indoors with PVC sheath;
incl. operating instructions, sold by the meter
Industrial Ethernet network manual max. length 1 000 m,
and configuration software minimum order 20 m
on CD-ROM
IE FC RJ45 Plug 180 2 x 2
• SCALANCE X104-2 6GK5104-2BB00-2AA3
4 x 10/100 Mbit/s RJ45 ports, RJ45 plug connector
electrical for Industrial Ethernet with a rugged
2 x BFOC ports, metal enclosure and integrated
optical (multimode, glass) insulation displacement contacts
up to 5 km for connecting Industrial Ethernet
• SCALANCE X106-1 6GK5106-1BB00-2AA3 FC installation cables;
6 x 10/100 Mbit/s RJ45 ports, with 180° cable outlet;
electrical for network components
1 x BFOC port, and CPs/CPUs with Industrial
optical (multi-mode, glass) Ethernet interface
up to 5 km • 1 pack = 1 unit 6GK1901-1BB10-2AA0
• SCALANCE X112-2 6GK5112-2BB00-2AA3 • 1 pack = 10 units 6GK1901-1BB10-2AB0
12 x 10/100 Mbit/s RJ45 ports, • 1 pack = 50 units 6GK1901-1BB10-2AE0
electrical
2 x BFOC ports, FC BFOC Plug 6GK1900-1GB00-0AC0
optical (multi-mode, glass)
Screw connector for on-site
up to 5 km
assembly on FC fiber-optic cable;
• SCALANCE X108 6GK5108-0BA00-2AA3 (1 pack = 20 units + cleaning
8 x 10/100 Mbit/s RJ45 ports, cloths)
electrical
• SCALANCE X108PoE 6GK5108-0PA00-2AA3 IE FC Stripping Tool 6GK1901-1GA00
6 x 10/100 Mbit/s RJ45 ports, Preadjusted stripping tool
electrical 2 x 10/100 Mbit/s for fast stripping of the Industrial
RJ45 PoE ports, electrical Ethernet FC cables
• SCALANCE X116 6GK5116-0BA00-2AA3
16 x 10/100 Mbit/s RJ45 ports, FC FO termination kit 6GK1900-1GL00-0AA0
electrical Assembly case for local assembly
• SCALANCE X124 6GK5124-0BA00-2AA3 of FC SC and FC BFOC connectors
24 x 10/100 Mbit/s RJ45 ports, to FC FO standard cable,
electrical comprising a stripping tool,
Kevlar cutters, fiber breaking tool
Accessories and microscope
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
SITOP compact 24 V/ 0.6 A 6EP1331-5BA00
(Type A)
1-phase power supply with
4-core, shielded TP installation wide-range input
cable for connection to IE 85 – 264 V AC/110 – 300 V DC,
FC Outlet RJ45/IE FC RJ45 Plug; stabilized output voltage 24 V,
PROFINET-compliant; rated output current value 0.6 A,
with UL approval; slim design
sold by the meter;
max. length 1 000 m,
minimum order 20 m
FO Standard Cable GP 6XV1873-2A
50/125/1400 1) 2)
Multimode cable,
sold by the meter;
max. length 1 000 m;
minimum order 20 m
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required
for pre-assembling glass fiber-optic cables
■ More information
Selection tools:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XC-100 unmanaged
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XC-100 unmanaged
■ Design ■ Function
The SCALANCE XC100-4OBRs with rugged enclosures are • Integration into optical Industrial Ethernet line, star and ring
optimized for mounting on a standard rail and the S7-300 or topologies
S7-1500 rail in different installation positions. Thanks to the • Fast bridging of network nodes using optical relays within
S7-1500 housing dimensions, the devices are suitable for inte- 10 ms in the event of a fault (e.g. power failure)
gration into an automation solution with S7-1500 components.
The SCALANCE XC100-4OBRs with degree of protection IP20
• Maintenance of network communication thanks to bridging of 2
the failed network components
are designed for operation in the control cabinet. The coated
PCBs (conformal coating) protect against condensation. • No activation of the redundancy manager when resetting a
network component in MRP and HRP ring topologies thanks to
The SCALANCE XC100-4OBR features: previous establishment of link;
• An enclosure in SIMATIC S7-1500 design with recessed fiber- this avoids a message burst in the network in the case of
optic interfaces planned maintenance work. Thanks to the configurable
• A row of LEDs for displaying status information connection delay, network components are not switched back
(bypass, display mode, power supply) into the network until they have been fully powered up and the
link has been established (only on versions with TAP function).
• A 4-pole terminal block for connecting the redundant supply
voltage (2 x 12 V DC ... 48 V DC) • Simple integration of the SCALANCE XC100-4OBR into
existing 100/1000 Mbit/s networks thanks to extensive
• A 2-pole terminal block for connecting the floating signaling portfolio of FO adapter cables
contact
• Simple diagnostics via signaling contact and LED on-site
• A 2-pole terminal block for connecting the digital input signal
(switching signal) Network topology and network configuration
• A SET pushbutton for on-site configuration of the monitored The Industrial Ethernet SCALANCE XC100-4OBRs with IP20
voltage range and the reset delay; degree of protection are usually installed in a control cabinet
optimal adaptation of the reset delay: together with the network components to be connected.
- short reset delay for unmanaged network components
- long reset delay for managed network components When configuring the network, the following parameters have to
be taken into account for calculating the cable length between
• Four FO SC interfaces for integration into the FO network and two devices:
connection of network components;
simple connection to active network components thanks to • The line attenuation of the fiber-optic cables used
extensive range of fiber-optic patch cords with different fiber- • The attenuation of the optical relay
optic connectors • The maximum number of SCALANCE XC100-4OBR bypass
relays that can be activated simultaneously
Commissioning and diagnostics
Before commissioning the SCALANCE XC100-4OBR, the reset
delay and the voltage range to be monitored must be selected
using the SET pushbutton on the device.
The following information is displayed by LEDs on site:
• Bypass
• Display mode
• Power supply
The SCALANCE XC100-4OBR can also be monitored using the
floating signaling contact. A digital input contact enables remote
function checking of the relay.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XC-100 unmanaged
■ Integration
2 SCALANCE
X320-3LD FE
SCALANCE
X320-3LD FE
SCALANCE
X320-3LD FE
SCALANCE SCALANCE
XC100-4OBR XC100-4OBR
G_IK10_XX_10360
SCALANCE SCALANCE SCALANCE
X320-3LD FE X320-3LD FE X320-3LD FE
SCALANCE SCALANCE
XC100-4OBR XC100-4OBR
SCALANCE
XR-300 with
Industrial Ethernet
redundancy SCALANCE
manager SCALANCE XR-300
XC100-4OBR
SCALANCE SCALANCE
XC100-4OBR XC100-4OBR
G_IK10_XX_10361
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XC-100 unmanaged
■ Technical specifications
Article No. 6GK5100-4AV00-2DA2 6GK5100-4AV00-2FA2 6GK5100-4AW00-2FA2
Product-type designation SCALANCE XC100-4OBR, SM, SCALANCE XC100-4OBR, SM SCALANCE XC100-4OBR, MM
LINE STRUCTURE
Product description Optical bypass relay for single-mode
fiber-optic networks without Tap func-
Optical bypass relay for single-mode
fiber-optic networks with Tap function
Optical bypass relay for multi-mode
fiber-optic networks with Tap function 2
tion
Electrical data
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s -
Interfaces
Transmission loss
• at Rx-In P1 and Tx-Out P2 1.2 dB 4.1 dB 4.5 dB
• at Rx-In P2 and Tx-Out P1 1.2 dB 4.1 dB 4.5 dB
• at Rx-In P1 and Tx-Out P1' 1.2 dB 5.7 dB 6 dB
• at Rx-In P2 and Tx-Out P2' 1.2 dB 5.7 dB 6 dB
• at Rx-In P1' and Tx-Out P1 1.2 dB 1.2 dB 1.5 dB
• at Rx-In P2' and Tx-Out P2 1.2 dB 1.2 dB 1.5 dB
Supply voltage
Type of voltage supply DC DC DC
Supply voltage external
• minimum 12 V 12 V 12 V
• maximum 48 V 48 V 48 V
Mechanical data
Material of the enclosure Metal/plastic Metal/plastic Metal/plastic
Design, dimensions and weight
Width 50 mm 50 mm 50 mm
Height 140 mm 140 mm 140 mm
Depth 125 mm 125 mm 125 mm
Net weight 550 g 550 g 550 g
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes
• wall mounting No No No
Permitted ambient conditions
Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C
Protection class IP IP20 IP20 IP20
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity Yes Yes Yes
• UL-registration Yes Yes Yes
Standard for hazardous zone
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XC-100 unmanaged
2
redundant voltage infeed, 1 400), FO ground cable (50/125/
signaling contact and digital input 1 400), flexible FO trailing cable,
contact INDOOR FO cable (62.5/125/900),
with four optical SC ports and 20 units
TAP function for fast link Multi-mode FO SC 6GK1901-0LB10-2AA0
establishment; duplex connector set
for integration into optical line or
ring topologies for FO standard cable (50/125/
• Multi-mode FO 6GK5100-4AV00-2DA2 1 400), FO ground cable (50/125/
1 400), flexible FO trailing cable,
• Single-mode FO 6GK5100-4AV00-2FA2 INDOOR FO cable (62.5/125/900),
with four optical SC ports and 10 units
reduced throughput attenuation
in the optical relay; Multi-mode FO LC duplex plug 6GK1901-0RB10-2AB0
for integration into optical line LC duplex plug (10 units) for
topologies INDOOR FO cable (62.5/125/900),
• Single-mode FO 6GK5100-4AW00-2FA2 FO robust cable GP (50/125/900),
FO standard cable (62.5/125/900)
Accessories
Single-mode FO LC duplex plug 6GK1901-0SB10-2AB0
FO Standard Cable GP 6XV1873-2A
50/125/1400 1) 2) LC duplex plug (10 units) for FO
robust cable GP (4E9/125/900)
Multi-mode cable
for use indoors and outdoors, Pre-assembled FO patch cables
sold by the meter;
max. length 1 000 m; Multi-mode
minimum order length 20 m MM FO Cord SC/SC 6XV1843-5EH10-0CC0
FO ground cable 6XV1873-2G With two SC duplex connectors,
50/125/1400 1) 2) 1m
Multi-mode cable for use in the MM FO Cord SC/BFOC 6XV1843-5EH10-0CB0
outdoor area, as well as for direct
routing underground; With one SC duplex connector and
longitudinally and laterally water- two BFOC connectors, 1 m
tight cable with non-metallic rodent
protection; MM FO Cord SC/LC 6XV1843-5EH10-0CA0
sold by the meter With one SC duplex connector and
max. length 2 000 m, one LC duplex connector, 1 m
minimum order 20 m
Single-mode
FO Robust Cable GP 6XV1873-2R
50/125/900 1) 2) SM FO Cord SC/SC 6XV1843-5FH10-0CC0
Multi-mode cable for outdoor and With two SC duplex connectors,
indoor use, as well as for direct 1m
routing underground; SM FO Cord SC/BFOC 6XV1843-5FH10-0CB0
longitudinally and laterally water-
tight cable with non-metallic rodent With one SC duplex connector and
protection; two BFOC connectors, 1 m
sold by the meter
max. length 2 000 m, SM FO Cord SC/LC 6XV1843-5FH10-0CA0
minimum order 20 m With one SC duplex connector and
FO Robust Cable GP 6XV1843-2R one LC duplex connector, 1 m
4E9/125/9001) 2)
Single-mode cable for outdoor and
indoor use, as well as for direct
routing underground;
longitudinally and laterally water-
tight cable with non-metallic rodent
protection;
sold by the meter
max. length 2 000 m,
minimum order 20 m
1) Special fiber-optic cables, lengths and accessories available on request
2) Special tools and trained personnel are required
for pre-assembling glass fiber-optic cables
■ More information
Selection tools: SIMATIC NET Selection Tool:
To assist in selecting the right Industrial Ethernet switches • Online version:
as well as configuration of modular variants, the SIMATIC NET http://www.siemens.com/snst
Selection Tool and the TIA Selection Tool are available at: • Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Overview
Hardware
SIMATIC environment
10 Gigabit Ethernet
Format module S7
Gigabit Ethernet
Modular design
LED diagnosis
Signal contact
PC module
PLUG slot
SCALANCE X-200
Type of device
X204-2 ● ● ● ● ● ● ●
X204-2TS ● ● ● ● ● ● ●
X204-2LD ● ● ● ● ● ● ●
X206-1 ● ● ● ● ● ● ●
X206-1LD ● ● ● ● ● ● ●
X208 ● ● ● ● ● ● ●
X208PRO ● ● ● ● ● ● ●
X212-2 ● ● ● ● ● ● ●
X212-2LD ● ● ● ● ● ● ●
X216 ● ● ● ● ● ● ●
X224 ● ● ● ● ● ● ●
XF204 ● ● ● ● ●
XF204-2 ● ● ● ● ●
XF206-1 ● ● ● ● ●
XF208 ● ● ● ● ●
X204RNA PRP ● ● ● ● ● ● ●
X204RNA EEC PRP ● ● ● ● ●
X204RNA HSR ● ● ● ● ● ● ●
X204RNA EEC HSR ● ● ● ● ●
X204RNA ● ● ● ● ●
EEC PRP+HSR
● applies
2/190
PRP
HSR
X224
X216
X208
device
XF208
XF204
X212-2
X206-1
X204-2
Type of
● applies
XF206-1
XF204-2
X204RNA
EEC PRP
EEC HSR
X204RNA
X204RNA
X204RNA
X204RNA
X208PRO
X212-2LD
X206-1LD
X204-2LD
X204-2TS
■ Overview (continued)
EEC PRP+HSR
Security Integrated (Firewall/VPN)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
PROFINET diagnosis
Siemens IK PI · 2015
SCALANCE X-200 managed
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Software
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Command Line Interface / Telnet
Industrial Ethernet Switches
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Web based Management
PROFINET/Industrial Ethernet
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Configuration with STEP 7 / TIA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
SNMP
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Ring redundancy incl. RM-functionality
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Passive Listening
IGMP Snooping/Querier (Internet Group
© Siemens AG 2014
Management Protocol)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● PRP communication
●
●
HSR communication
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
• Switches with electrical and optical ports
■ Overview for glass single mode FOC up to 26 km:
- SCALANCE X204-2LD;
for constructing optical line or ring topologies with four
electrical ports and two optical ports
- SCALANCE X206-1LD;
for constructing star topologies with 6 electrical ports and
1 optical port, line or ring topologies with electrical and 2
optical transmission paths
- SCALANCE X212-2LD;
for constructing optical line or ring topologies with
12 electrical ports and 2 optical ports
• Switches with electrical ports for configuring electrical
Industrial Ethernet line, star or ring topologies:
- SCALANCE X208;
with 8 electrical ports for mounting in the control cabinet
- SCALANCE X208PRO (IP65/67 degree of protection);
with 8 electrical ports especially for use outside the control
cabinet (M12 connection system)
- SCALANCE X216;
with 16 electrical ports for mounting in the control cabinet
- SCALANCE X224;
The managed Industrial Ethernet switches of the with 24 electrical ports for mounting in the control cabinet
SCALANCE X-200 line are optimized for setting up Industrial
Ethernet networks at data transfer rates of 10/100 Mbit/s in a line,
star or ring topology. ■ Benefits
• Integrated redundancy manager for constructing
Fast Ethernet ring topologies with fast media redundancy
• Electrical or optical connection to stations or network in
accordance with the port type of the devices
• Ideal solution for configuring Industrial Ethernet line, star and
• Rugged metal housing in S7-300 format for mounting on ring topologies
standard rail, S7-300 standard mounting rail or for direct wall
mounting in various positions • Reliable plug-in connection thanks to rugged, industry-
standard device connection in conjunction with PROFINET-
• Rugged, industry-standard station connections with compliant FastConnect connectors
PROFINET-compatible RJ45 connectors that offer additional
strain relief and bending strain relief thanks to latching on the • High network availability through design of redundant ring
housing structures (redundancy manager integrated)
• Redundant power supply • Integration of the SCALANCE X-200 switches in the existing
network management infrastructure through SNMP access
• Diagnostics on the device by means of LEDs point
(power, link status, data communication)
• Easy integration in the process diagnosis and system
• Error signaling contact with easy adjustment using the SET diagnosis with PROFINET
button
• Configuration and diagnostics integrated into STEP 7 provide
• PROFINET diagnostics, SNMP access, integrated web server significant benefits during engineering, commissioning, and
and automatic e-mail transmission function for remote the operating phase of a plant
diagnostics and signaling via the network
• Module replacement without the need for a programming
Product versions device, using the C-PLUG swap media for backing up the
• Switches with electrical and optical ports configuration data
for glass multi-mode FOC up to 5 km:
- SCALANCE X204-2;
for constructing optical line or ring topologies with four
electrical ports and two optical ports
- SCALANCE X204-2TS (degree of protection IP20);
for setting up optical line or ring topologies with four
electrical ports and two optical ports especially for railway
applications (EN 50155) with extended temperature range
- SCALANCE X206-1;
for setting up star topologies with 6 electrical ports
and 1 optical port, line or ring topologies with electrical and
optical transmission paths
- SCALANCE X212-2;
for constructing optical line or ring topologies with
12 electrical ports and two optical ports
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Application
The SCALANCE X-200 Industrial Ethernet switches permit cost- Features:
effective configuration of Industrial Ethernet line, star or ring • The RJ45 ports are industry-standard and feature additional
topologies with switching functionality for networks in which high retaining collars (except for SCALANCE X208PRO), for
availability or remote diagnostics options are required. The de-
2
connection to the IE FC RJ45 Plug 180
vices with IP30 degree of protection have been designed for use
in the control cabinet. The SCALANCE X208PRO is designed • The eight PROFINET-compliant M12 ports (d-coded) of the
to the IP65/67 degree of protection for installation outside the SCALANCE X208PRO are designed with IP65/67 degree of
control cabinet. The SCALANCE X204-2TS (TS = Transportation protection for connection to the IE FC M12 Plug PRO 2x2 or
Systems) is suitable for use in railway applications due to its the pre-assembled IE M12 connecting cable
specification according to EN 50155. • The SCALANCE X208PRO can be mounted on a DIN rail or
S7-300 rail or direct on the equipment or machine;
the status information can be read off regardless of the
mounting position thanks to the angled LED strip.
• Power can also be supplied to the SCALANCE X208PRO from
outside the control cabinet from the PS791-1PRO power
supply module at 230 V AC.
100
Mbit/s
FO ring cabinet
IE FC
10/100 Mbit/s
Outlet
RJ45 Switch Switch Switch
SCALANCE SCALANCE SCALANCE
X208 X208 X208
ET 200SP PROFIBUS
G_IK10_XX_10117
Data access over the network
electrical network FC Standard Cable
optical network
Diagnostics access over SNMP and Web browser with SCALANCE X208
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Design ■ Function
The SCALANCE X-200 Industrial Ethernet switches with a rug- • Configuring electrical and optical Industrial Ethernet line, star
ged metal housing are optimized for mounting on a standard rail and ring topologies
and an S7-300 rail. Direct wall mounting in various positions is • Fast redundancy in the ring with
also possible. Thanks to the S7-300 housing dimensions, the de- - High Speed Redundancy Protocol (HRP); up to 0.3 seconds
vices are suitable for integration into an automation solution with
S7-300 components.
for reconfiguration of the ring with 50 switches in the ring
- PROFINET MRP (Media Redundancy Protocol); up to
2
The switches with IP20/IP30 degree of protection feature: 0.2 seconds for reconfiguration of the ring with 50 switches
in the ring
• A 4-pole terminal block for connecting the redundant supply
voltage (2 x 24 V DC) • The functioning of the ring is continuously monitored by the
integrated redundancy manager. It recognizes failure of a
• A row of LEDs to indicate the status information (power, link transmission path in the ring or failure of a SCALANCE X-200
status, data exchange, power supply, signaling contact) and activates the substitute path within 0.3 seconds or
• A 2-pole terminal block for connecting the floating signaling 0.2 seconds with MRP
contact • Use in ring topologies (100 Mbit/s) together with
• A SET button for on-site configuration of the signaling contact SCALANCE X-300, SCALANCE X-400 and SCALANCE X-500
The SCALANCE X208PRO with IP65/67 degree of protection • Uncrossed connecting cables can be used due to
features: Autocrossover function integrated in the ports
• 2 x M12 interfaces for connecting the redundant supply • Easy diagnostics using signaling contact, SNMP and Web
voltage (2 x 24 V DC) browser
• A row of LEDs to indicate the status information (power, link • Easy copper cable diagnostics with Web browser for local-
status, data exchange, power supply, signaling contact) izing cable breaks
• An M12 interface for connecting the isolated signaling contact • Integration into the diagnostics of a PROFINET I/O controller
with expanded diagnostics functions for a consistent
The SCALANCE X-200 switches are available with the following diagnostics concept, including network infrastructure
port types: • Diagnosis of data traffic by means of a parameterizable mirror
• 10/100BaseTX, RJ45 or M12 connection; port with a standard commercial network analyzer
RJ45 or M12 port, automatic detection of the data rate (10 or • Optimized support of PROFINET real-time communication
100 Mbit/s), with autosensing and autocrossover functions (RT) through prioritizing
for connecting IE FC cables using IE FC RJ45 Plug 180 or
IE FC M12 Plug PRO up to 100 m. • Fast device replacement in the event of a fault by using the
optional C-PLUG swap medium (not included in scope of
• 100BaseFX, BFOC connection technique; supply)
BFOC ports for direct connection to Industrial Ethernet glass
fiber-optic cables up to 5 km (multimode FOC) or up to 26 km Network topology and network configuration
(singlemode FOC) for configuring line, ring and star topol-
ogies. The Industrial Ethernet SCALANCE X-200 switches with IP30
degree of protection are usually installed in a control cabinet
together with the stations to be connected. Electrical and optical
versions can be installed together in star, line and ring topolo-
gies. The SCALANCE X208PRO is designed for installation
outside the control cabinet.
When configuring the network, it is necessary to observe the
following boundary conditions:
• Length of the TP cable between two SCALANCE X switches:
- Max. 100 m with IE FC cable and IE FC RJ45 Plug 180 or
IE FC M12 Plug PRO
- Max. 10 m using patches with TP cord
• Length of the optical cables
- Max. 5 000 m with Industrial Ethernet glass fiber-optic
cables (multimode)
- Max. 26 000 m with Industrial Ethernet glass fiber-optic
cables (singlemode)
• IP Address:
The IP address is assigned by means of the DHCP (Dynamic
Host Configuration Protocol). If there is no corresponding
server in the network, the IP address can be assigned using
the supplied software tool PST (Primary Setup Tool) or STEP 7.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Function (continued)
ET 200pro ET 200pro
S7-300 with CP 343-1
Operator control
and monitoring
Field PG
ET 200S
Power Supply SCALANCE
PS791-1PRO X208PRO
IPC with
CP 1616
230 V AC
SCALANCE
W788
24 V DC
24 V DC Mobile Panel
G_IK10_XX_10078
277 IWLAN
230 V AC
PROFINET
Industrial Ethernet
Star network topology with SCALANCE X208PRO outside the control cabinet and 230 V AC power supply
S7-400
Operator Station PC
zjhshujl
YY[
PROFINET
Industrial Ethernet
ET 200S
ET 200S
nprXWXWYXX
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Function (continued)
S7-400
2
Operator Station
ET 200MP S7-300
PC SCALANCE
X204-2 S7-1500
SCALANCE SCALANCE
X206-1 X206-1
S7-300
IPC
SCALANCE X208
PC
IPC ET 200SP
HMI S7-300
G_IK10_XX_10113
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic) S7-400
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ Technical specifications
Article No. 6GK5204-2BB10-2AA3 6GK5204-2BC10-2AA3 6GK5204-2BB10-2CA2
Product-type designation SCALANCE X204-2 SCALANCE X204-2LD SCALANCE X204-2TS
Transmission rate
2 Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
Interfaces
Number of electrical/optical
connections
• for network components 6 6 6
or terminal equipment maximum
Number of electrical connections
• for network components 4 4 4
and terminal equipment
• for signaling contact 1 1 1
• for power supply 1 1 1
• for redundant power supply 1 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces 2 2 2
for optical waveguide at 100 Mbit/s
Design of optical interface BFOC sockets (multimode up to 5 km) BFOC port (singlemode up to 26 km) BFOC sockets (multimode up to 5 km)
for optical waveguide at 100 Mbit/s
Connectable optical power relative
to 1 mW
• of the transmitter output -19 … -14 dB -15 … -7 dB -19 … -14 dB
• of the receiver input maximum - - -
Optical sensitivity relative to 1 mW -34 dB -34 dB -34 dB
of the receiver input minimum
Attenuation of fiber-optic cable 0 dB 0 dB 0 dB
transmission link minimum necessary
Range at the optical interface 0 … 5 km 0 … 26 km 0 … 5 km
depending on the optical fiber used
Design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling con- 24 V 24 V 24 V
tacts at DC rated value
Operating current of signaling con- 0.1 A 0.1 A 0.05 A
tacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC
Supply voltage external 24 V 24 V 12 V
• minimum 18 V 18 V 10 V
• maximum 32 V 32 V 30 V
Product component fusing at power Yes Yes Yes
supply input
Type of fusing at input 0.6 A / 60 V 0.6 A / 60 V 3 A / 32 V
for supply voltage
Consumed current maximum 0.265 A 0.265 A 0.6 A
Active power loss at 24 V for DC 6.36 W 6.36 W 6.6 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
2 Product function
• Port diagnostics Yes Yes Yes
• Statistics packet size Yes Yes Yes
• Statistics packet type Yes Yes Yes
• Error statistics Yes Yes Yes
Product functions DHCP
Product function DHCP client Yes Yes Yes
Product functions Redundancy
Product function
• Ring redundancy Yes Yes Yes
• Redundancy manager Yes Yes Yes
• Standby redundancy No No No
• High Speed Redundancy Protocol Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes
• Parallel Redundancy Protocol (PRP) No No No
• Passive listening Yes Yes Yes
Protocol is supported PRP Yes Yes Yes
Product functions Security
Protocol is supported SSH Yes Yes Yes
Product functions Time
Product function
• SICLOCK support Yes Yes Yes
Protocol is supported
• NTP No No No
• SNTP Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0 : 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 (2) G Ex nA EN 60079-15: 2005, II 3 G Ex nA II T4 EN 60079-15: 2005, II 3 (2) G Ex nA
[op is] IIC T4, KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145X [op is] IIC T4, KEMA 07 ATEX 0145 X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, CSA C22.2 No. ANSI / ISA 12.12.01, CSA C22.2 No. ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C, 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, 213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4 D T4, CL. 1 / Zone 2 / GP. IIC, T4 D T4, CL. 1 / Zone 2 / GP. IIC, T4
• for emitted interference EN 61000-6-4:2001 (Class A) EN 61000-6-4 (Class A) EN 61000-6-4 (Class A)
• for interference immunity EN 61000-6-4:2001 EN 61000-6-2 EN 61000-6-2
Verification of suitability EN 61000-6-4:2001 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval Yes Yes Yes
• Railway application in accordance No No Yes
with EN 50155
• Railway application in accordance No No No
with EN 50124-1
Marine classification association
• American Bureau of Shipping Eu- Yes Yes No
rope Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes No
• Det Norske Veritas (DNV) Yes Yes No
• Germanische Lloyd (GL) Yes Yes No
• Lloyds Register of Shipping (LRS) Yes Yes No
• Nippon Kaiji Kyokai (NK) Yes Yes No
• Polski Rejestr Statkow (PRS) Yes Yes No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
2 Ambient temperature
• during operating -40 °C … + 60 °C -40 °C … + 60 °C -40 °C … + 60 °C -40 °C … + 70 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP30 IP30 IP30 IP65/67
Design, dimensions and weight
Design compact compact compact compact
Width 60 mm 60 mm 60 mm 90 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 124 mm 124 mm 124 mm 124 mm
Net weight 0.78 kg 0.78 kg 0.78 kg 1 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on Any (depending only on Any (depending only on Any (depending only on
of star structuring signal propagation time) signal propagation time) signal propagation time) signal propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• SMTP server - - - -
• Port mirroring Yes Yes Yes Yes
• for IRT PROFINET IO switch No No No No
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes Yes
• HTTP Yes Yes Yes Yes
• HTTPS Yes Yes Yes Yes
• TFTP Yes Yes Yes Yes
• FTP Yes Yes Yes Yes
• BOOTP No No No No
• SNMP v1 Yes Yes Yes Yes
• SNMP v2 Yes Yes Yes Yes
• SNMP v3 Yes Yes Yes Yes
• DCP Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes Yes
• I&M1 - higher level Yes Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
2 Product function
• Port diagnostics Yes Yes Yes Yes
• Statistics packet size Yes Yes Yes Yes
• Statistics packet type Yes Yes Yes Yes
• Error statistics Yes Yes Yes Yes
Product functions DHCP
Product function DHCP client Yes Yes Yes Yes
Product functions Redundancy
Product function
• Ring redundancy Yes Yes Yes Yes
• Redundancy manager Yes Yes Yes Yes
• Standby redundancy No No No No
• High Speed Redundancy Protocol Yes Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes Yes
• Parallel Redundancy Protocol (PRP) No No No No
• Passive listening Yes Yes Yes Yes
Protocol is supported PRP Yes Yes Yes Yes
Product functions Security
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP No No No No
• SNTP Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1,
Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, EN 60079-15: 2005, EN 60079-15: 2005, EN 60079-15: 2005,
II 3 (2) G Ex nA [op is] IIC T4, II 3 G Ex nA II T4 KEMA 07 II 3 G Ex nA II T4 KEMA 07 II 3 G Ex nA II T4 KEMA 07
KEMA 07 ATEX 0145 X ATEX 0145X ATEX 0145X ATEX 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01,
CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987,
CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D
T4, CL. 1 / Zone 2 / T4, CL. 1 / Zone 2 / T4, CL. 1 / Zone 2 / T4, CL. 1 / Zone 2 /
GP. IIC, T4 GP. IIC, T4 GP. IIC, T4 GP. IIC, T4
• for emitted interference EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2001 EN 61000-6-2:2001 EN 61000-6-2:2001 EN 61000-6-2:2001
Verification of suitability EN 61000-6-2:2001, EN 61000-6-2:2001, EN 61000-6-2:2001, EN 61000-6-2:2001,
EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
Marine classification association
• American Bureau Yes Yes Yes Yes
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes Yes Yes
• Det Norske Veritas (DNV) Yes Yes Yes Yes
• Germanische Lloyd (GL) Yes Yes Yes Yes
• Lloyds Register of Shipping (LRS) Yes Yes Yes Yes
• Nippon Kaiji Kyokai (NK) Yes Yes Yes Yes
• Polski Rejestr Statkow (PRS) No No No No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
2
with integral SNMP access,
online diagnostics, copper cable 4-core, shielded TP installation
diagnostics and PROFINET cable for connection to
diagnostics for configuring line, star IE FC Outlet RJ45/IE FC RJ45 Plug;
and ring topologies; PROFINET-compatible;
with integrated redundancy with UL approval;
manager (exception: SCALANCE sold by the meter;
X208PRO); max. length 1 000 m,
incl. operating instructions, minimum order quantity 20 m
Industrial Ethernet network manual FO Standard Cable GP 6XV1873-2A
and configuration software 50/125/1400 1) 2)
on CD-ROM
Multimode cable,
• With electrical and optical ports
sold by the meter;
for glass multimode FOC up to
max. length 1 000 m;
max. 5 km
minimum order 20 m;
- SCALANCE X204-2 6GK5204-2BB10-2AA3
with four 10/100 Mbit/s FO Robust Cable GP 6XV1843-2R
RJ45 ports and two fiber-optic 4E9/125/90
ports
Singlemode cable,
- SCALANCE X204-2TS 6GK5204-2BB10-2CA2 sold by the meter;
with four 10/100 Mbit/s max. length 1 000 m;
RJ45 ports and two fiber-optic minimum order 20 m
ports with extended temperature
range and EN 50155 approval FC FO Standard Cable GP 6XV1847-2A
for railway applications 62.5/200/230
- SCALANCE X206-1 6GK5206-1BB10-2AA3 FC FO standard cable for fixed rout-
with six 10/100 Mbit/s ing indoors with PVC sheath;
RJ45 ports and one fiber-optic sold by the meter
port max. length 1 000 m;
- SCALANCE X212-2 6GK5212-2BB00-2AA3 minimum order 20 m
with twelve 10/100 Mbit/s
RJ45 ports and two fiber-optic IE FC RJ45 Plug 180 2 x 2
ports RJ45 plug connector for
• With electrical and optical ports Industrial Ethernet with a rugged
for glass single mode FOC up to metal enclosure and integrated
max. 26 km insulation displacement contacts
- SCALANCE X204-2LD 6GK5204-2BC10-2AA3 for connecting Industrial Ethernet
with four 10/100 Mbit/s FC installation cables;
RJ45 ports and two long-dis- with 180° cable outlet;
tance fiber-optic ports for network components and
- SCALANCE X206-1LD 6GK5206-1BC10-2AA3 CPs/CPUs with Industrial Ethernet
with six 10/100 Mbit/s interface
RJ45 ports and one long-dis- • 1 pack = 1 unit 6GK1901-1BB10-2AA0
tance fiber-optic port • 1 pack = 10 units 6GK1901-1BB10-2AB0
- SCALANCE X212-2LD 6GK5212-2BC00-2AA3 • 1 pack = 50 units 6GK1901-1BB10-2AE0
with twelve 10/100 Mbit/s
RJ45 ports and two long-dis- FC BFOC Plug 6GK1900-1GB00-0AC0
tance fiber-optic ports Screw connector for on-site
• With electrical ports assembly on FC fiber-optic cable;
- SCALANCE X208; 6GK5208-0BA10-2AA3 (1 pack = 20 units + cleaning
with eight 10/100 Mbit/s cloths)
RJ45 ports IE FC M12 Plug PRO 2 x 2
- SCALANCE X208PRO 6GK5208-0HA10-2AA6
with eight 10/100 Mbit/s M12 plug connector
M12 ports, incl. eleven M12 dust for connection of Industrial Ethernet
protection caps, IP65 degree of FC installation cables;
protection 4-pole, D-coded, metal enclosure,
IP65 degree of protection,
- SCALANCE X216 6GK5216-0BA00-2AA3
pin insert;
with sixteen 10/100 Mbit/s
180° cable outlet;
RJ45 ports
for network components and
- SCALANCE X224 6GK5224-0BA00-2AA3 Industrial Ethernet stations with
with twenty-four 10/100 Mbit/s IP65/IP67 degree of protection
RJ45 ports • 1 pack = 1 unit 6GK1901-0DB20-6AA0
• 1 pack = 8 units 6GK1901-0DB20-6AA8
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required for pre-assembling glass
fiber-optic cables
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
■ More information
Selection tools:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
■ Application
The SCALANCE XF-200 Industrial Ethernet switches permit Features:
cost-effective configuration of Industrial Ethernet line, star or ring • Device diagnostics with LEDs
topologies with switching functionality for networks in which (power, link status, data communication)
high availability or remote diagnostics options are required.
2 The devices with degree of protection IP20 are designed for
operation in the control cabinet.
• Remote diagnostics by means of signaling contact,
PROFINET, SNMP, and Web browser
• The RJ45 sockets are designed to be industry-compatible
with additional sleeves, for connection of the
IE FC RJ45 Plug 180
S7-400
Operator Station
S7-300
Switching cabinet
S7-400
SCALANCE
XF204 ET 200S TP 177B
PC SCALANCE
X204-2
SCALANCE SCALANCE
X206-1 X206-1
S7-300
IPC
SCALANCE X208
PC
IPC
S7-400
S7-300
S7-400
G_IK10_XX_10257
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic) S7-400
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
Network topology and network configuration
■ Design
The SCALANCE XF-200 Industrial Ethernet switches with IP20
The SCALANCE XF-200 managed Industrial Ethernet switches degree of protection are usually installed in a control cabinet
are designed for installation on a standard DIN rail. With their together with the stations to be connected. Electrical and optical
enclosure in ET 200S format (slim design), the devices are versions can be installed together in star, line and ring topolo-
optimally suited for integration in automation solutions in small
2
gies.
control boxes together with the ET200S.
When configuring the network, it is necessary to observe the
The switches with IP20 degree of protection feature: following boundary conditions:
• A 4-pole terminal block for connecting the redundant supply • Length of the TP cable between two SCALANCE XF switches:
voltage (2 x 24 V DC) - Max. 100 m with IE FC cable and IE FC RJ45 Plug 180
• A row of LEDs to indicate the status information (power, link - Max. 10 m using patches with TP cord
status, data traffic, power supply, signaling contact) • Length of the optical cables
• A 2-pole terminal block for connecting the isolated signaling - Max. 5 000 m with Industrial Ethernet glass fiber-optic
contact cables (multimode)
• A SET button for on-site configuration of the signaling contact • IP address:
The IP address is assigned by means of the DHCP (Dynamic
The SCALANCE XF-200 switches are available with the following Host Configuration Protocol). If there is no corresponding
port types: server in the network, the IP address can be assigned using
• 10/100BaseTX, RJ45 connection; the supplied software tool PST (Primary Setup Tool) or STEP 7.
RJ45 socket, automatic detection of the data rate (10 or 100 The SCALANCE XF-200 switches are configured with STEP 7.
Mbit/s), with Autosensing and Autocrossover functions for
connecting IE FC cables using the IE FC RJ45 Plug 180. Commissioning and diagnostics
• 100BaseFX, BFOC connection technique; PROFINET diagnostic interrupts from SCALANCE XF-200
BFOC sockets for direct connection to Industrial Ethernet switches can be displayed with the appropriate SIMATIC Engi-
glass fiber-optic cables up to 5 km (multimode fiber-optic neering Tools and processed in the controller with expanded
cable) for configuring line, ring, and star topologies. diagnostics function. The engineering outlay for the PLC and
HMI have been drastically reduced due to the complete integra-
■ Function tion in the SIMATIC concept for system error messages.
• Setup of electrical and optical Industrial Ethernet line, star and The SCALANCE XF-200 Industrial Ethernet switches can also be
ring topologies integrated into a network management system through the
standardized protocol SNMP (Simple Network Management
• Fast redundancy in the ring with High Speed Redundancy Protocol). In the event of a fault in the device, error messages
(HSR); up to 0.3 seconds for reconfiguration of the ring with (SNMP traps) can be sent to a network system or as e-mail to a
50 switches in the ring specified network administrator.
• Fast redundancy in the ring with PROFINET-compliant Media
The integral Web server enables configuration and diagnostics
Redundancy Protocol (MRP); max. 0.2 seconds required for
settings to be made using a standard browser (e.g. port config-
reconfiguration of the ring with 50 switches in the ring
uration). Statistical information can also be read out over the
• The functioning of the ring is continuously monitored by the Web server (e.g. port capacity utilization).
integrated redundancy manager. It recognizes failure of a
transmission path in the ring or failure of a SCALANCE XF-200 The following information is displayed on site by LEDs:
and activates the substitute path within 0.3 or 0.2 seconds • Power
• Use in ring topologies (100 Mbit/s) together with • Port status
SCALANCE X-400, SCALANCE X-300, SCALANCE X-200, • Data traffic
SCALANCE X-200IRT
• Signaling contact
• Uncrossed connecting cables can be used due to
Autocrossover function integrated in the ports • Redundancy manager function
• Load disconnection through integral switch functionality The Industrial Ethernet switches of the SCALANCE XF-200 line
• Easy diagnostics using signaling contact, SNMP and Web can also be monitored using the floating signaling contact.
browser
• Easy copper cable diagnostics with Web browser for
localizing cable breaks
• Integration into the diagnostics of a PROFINET I/O controller
with expanded diagnostics functions for a consistent
diagnostics concept, including network infrastructure
• Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
• Fast device replacement in the event of a fault by using the
optional C-PLUG swap medium (not included in scope of
supply)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
■ Technical specifications
Article No. 6GK5204-0BA00-2AF2 6GK5204-2BC00-2AF2 6GK5206-1BC00-2AF2 6GK5208-0BA00-2AF2
Product-type designation SCALANCE XF204 SCALANCE XF204-2 SCALANCE XF206-1 SCALANCE XF208
Transmission rate
2 Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 10 Mbit/s
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical connec-
tions
• for network components or terminal 4 6 7 8
equipment maximum
Number of electrical connections
• for network components and termi- 4 4 6 8
nal equipment
• for signaling contact 1 1 1 1
• for power supply 1 1 1 1
• for redundant power supply 1 1 1 1
Design of electrical connection
• for network components and termi- RJ45 port RJ45 port RJ45 port RJ45 port
nal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces - 2 1 -
for optical waveguide at 100 Mbit/s
Design of optical interface - BFOC sockets (multimode BFOC sockets (multimode -
for optical waveguide at 100 Mbit/s up to 5 km) up to 5 km)
Connectable optical power relative
to 1 mW
• of the transmitter output - -19 … -14 dB -19 … -14 dB -
Optical sensitivity relative to 1 mW - -34 dB - -
of the receiver input minimum
Attenuation of fiber-optic cable - 0 dB 0 dB -
transmission link minimum necessary
Range at the optical interface - 0 … 5 km 0 … 5 km -
depending on the optical fiber used
Design of the removable storage Yes Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC DC
Supply voltage external 24 V 24 V 24 V 24 V
• minimum 18 V 18 V 18 V 18 V
• maximum 32 V 32 V 32 V 32 V
Product component fusing Yes Yes Yes Yes
at power supply input
Type of fusing at input 1.1 A / 33 V 1.1 A / 33 V 1.1 A / 33 V 1.1 A / 33 V
for supply voltage
Consumed current maximum 0.11 A 0.22 A 0.17 A 0.13 A
Active power loss at 24 V for DC 2.64 W 5.28 W 4.08 W 3.12 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
2 Product function
• Port diagnostics Yes Yes Yes Yes
• Statistics packet size Yes Yes Yes Yes
• Statistics packet type Yes Yes Yes Yes
• Error statistics Yes Yes Yes Yes
Product functions DHCP
Product function DHCP client Yes Yes Yes Yes
Product functions Redundancy
Product function
• Ring redundancy Yes Yes Yes Yes
• Redundancy manager Yes Yes Yes Yes
• Standby redundancy No No No No
• High Speed Redundancy Protocol Yes Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes Yes
• Parallel Redundancy Protocol (PRP) No No No No
• Passive listening Yes Yes Yes Yes
Protocol is supported PRP Yes Yes Yes Yes
Product functions Security
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP No No No No
• SNTP Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1, Group A, B, C, D / T4, CL.1,
Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 (2) G EN 60079-15: 2005, II 3 (2) G EN 600EN 60079-15: 2005,
nA II T4, KEMA 07 ATEX Ex nA [op is] IIC T4, KEMA Ex nA [op is] IIC T4, KEMA II 3 G Ex nA II T4, KEMA 07
0145 X 07 ATEX 0145 X 07 ATEX 0145 X ATEX 0145 X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, CSA UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, CSA ANSI / ISA 12.12.01, CSA ANSI / ISA 12.12.01, CSA ANSI / ISA 12.12.01, CSA
C22.2 No. 213-M1987, CL. 1 C22.2 No. 213-M1987, CL. 1 C22.2 No. 213-M1987, CL. 1 C22.2 No. 213-M1987, CL. 1
/ Div. 2 / GP. A, B, C, D T4, / Div. 2 / GP. A, B, C, D T4, / Div. 2 / GP. A, B, C, D T4, / Div. 2 / GP. A, B, C, D T4,
CL. 1 / Zone 2 / GP. IIC, T4 CL. 1 / Zone 2 / GP. IIC, T4 CL. 1 / Zone 2 / GP. IIC, T4 CL. 1 / Zone 2 / GP. IIC, T4
• for emitted interference EN 61000-6-4:2001 ( EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-4:2001 EN 61000-6-2:2001 EN 61000-6-2:2001 EN 61000-6-2:2001
Verification of suitability EN 61000-6-4:2001 EN 61000-6-2:2001, EN 61000-6-2:2001, EN 61000-6-2:2001,
EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
Marine classification association
• American Bureau No No No No
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes No No No
• Det Norske Veritas (DNV) No No No No
• Germanische Lloyd (GL) No No No No
• Lloyds Register of Shipping (LRS) No No No No
• Nippon Kaiji Kyokai (NK) No No No No
• Polski Rejestr Statkow (PRS) No No No No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200 managed
2
integrated SNMP access, online metal enclosure and integrated
diagnostics, copper cable diagnos- insulation displacement contacts
tics and PROFINET diagnostics for for connecting Industrial Ethernet
configuring line, star and ring topol- FC installation cables;
ogies; with integrated redundancy with 180° cable outlet;
manager; incl. operating instruc- for network components and
tions, Industrial Ethernet network CPs/CPUs with Industrial Ethernet
manual and configuration software interface
on CD-ROM • 1 pack = 1 unit 6GK1901-1BB10-2AA0
• SCALANCE XF204-2 6GK5204-2BC00-2AF2 • 1 pack = 10 units 6GK1901-1BB10-2AB0
4 x 10/100 Mbit/s RJ45 ports, • 1 pack = 50 units 6GK1901-1BB10-2AE0
electrical;
2 x 100 Mbit/s BFOC ports, optical FC BFOC plug 6GK1900-1GB00-0AC0
(multimode, glass), up to 5 km
Screw connector for on-site
• SCALANCE XF206-1 6GK5206-1BC00-2AF2 assembly on FC fiber-optic cable;
6 x 10/100 Mbit/s RJ45 ports, (1 pack = 20 units + cleaning
electrical; cloths)
1 x 100 Mbit/s BFOC ports, optical
(multimode, glass), up to 5 km IE FC stripping tool 6GK1901-1GA00
• SCALANCE XF204 6GK5204-0BA00-2AF2
Preadjusted stripping tool
4 x 10/100 Mbit/s RJ45 ports,
for fast stripping of Industrial
electrical
Ethernet FC cables
• SCALANCE XF208 6GK5208-0BA00-2AF2
8 x 10/100 Mbit/s RJ45 ports, FC FO termination kit 6GK1900-1GL00-0AA0
electrical
Assembly case for local assembly
Accessories of FC SC and FC BFOC connectors
to FC FO standard cable,
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10 comprising a stripping tool,
(Type A) Kevlar cutters, fiber breaking tool
4-core, shielded TP installation and microscope
cable for connection to SITOP compact 24 V/ 0.6 A 6EP1331-5BA00
IE FC RJ45 outlet / IE FC RJ45 plug;
PROFINET-compliant; 1-phase power supply
with UL approval; with wide-range input
sold by the meter; 85 – 264 V AC/110 – 300 V DC,
max. length 1 000 m, stabilized output voltage 24 V,
minimum order 20 m rated output current value 0.6 A,
slim design
FO Standard Cable GP 6XV1873-2A
50/125/1400 1) 2) C-PLUG 6GK1900-0AB00
Multimode cable, Swap medium for simple
sold by the meter; replacement of devices in the
max. length 1 000 m; event of a fault;
minimum order 20 m; for storing configuration or
engineering and application data;
FC FO Standard Cable GP 6XV1847-2A can be used for SIMATIC NET
62.5/200/230 products with C-PLUG slot
FC FO standard cable for fixed
routing indoors with PVC sheath;
sold by the meter
max. length 1 000 m;
minimum order 20 m
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required for pre-assembling
glass fiber-optic cables
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
Commissioning and diagnosis
■ Design
The SCALANCE X-200RNA Industrial Ethernet network access
The SCALANCE X204RNA and X204RNA EEC network access points can be integrated into a network management system via
points with rugged plastic or metal enclosure have been opti- the standardized protocol SNMP (Simple Network Management
mized for installation on a standard mounting rail and for direct Protocol). In the event of a fault in the device, error messages
wall mounting in different mounting positions.
2
(SNMP traps) can be sent to a network system or as e-mail to a
The network access points with IP20 degree of protection specified network administrator.
feature: The integral Web server enables configuration and diagnostics
• A 4-pole terminal block for connecting the redundant supply settings to be made using a standard browser (e.g. port config-
voltage (2 x 24 V DC), or a 3-pole terminal block in the case of uration). Statistical information can also be read out over the
the wide-range power supply unit Web server (e.g. port capacity utilization).
• A row of LEDs to indicate the status information (power, link The following information is displayed on site by LEDs:
status, data exchange, power supply, signaling contact)
• Power
• A 2-pole or 3-pole terminal block for connecting the floating
• Port status
signaling contact in the corresponding voltage range
• Data traffic
• A SET button for on-site configuration of the signaling contact
• Signaling contact
The SCALANCE X200RNA devices are available with the follow-
ing port types: • PRP activity
• 100BaseTX, RJ45 connection; The SCALANCE X-200RNA Industrial Ethernet network
RJ45 port with a data rate of 100 Mbit/s, with autosensing and access points can also be monitored using the floating signaling
autocrossover function for the connection of IE FC cables via contact.
IE FC RJ45 Plug 180 up to 100 m
• 100BaseTX, combo port (RJ45, SFP slot); ■ Integration
100 Mbit/s combo ports for direct connection to Industrial
Ethernet copper cables or glass fiber-optic cables
(multimode/singlemode fiber-optic cable); PG/PC/IPC with Server with
if the RJ45 interface of the combo port is used, the SFP slot is SOFTNET-IE RNA SOFTNET-IE
deactivated, and vice versa. RNA
■ Function
Industrial
• Connection of non-PRP-enabled terminal equipment to
Ethernet
parallel, separate networks
(LAN A)
• Parallel data transfer over two parallel, separate networks
Industrial
• Uncrossed connecting cables can be used due to Ethernet
Autocrossover function integrated in the ports (LAN B)
• Easy diagnostics using signaling contact, SNMP and Web SIPROTEC SCALANCE
browser X204RNA
• Fast device replacement in the event of a fault by using the
optional C-PLUG swap medium (not included in scope of
supply) SIMATIC PC
S7-400 with
Network topology and network configuration
G_IK10_XX_10333
CP 443-1RNA
The SCALANCE X-200RNA switches with IP30 degree of protec-
tion are usually installed in a control cabinet together with the
stations to be connected. They can be mixed electrically and
optically in star and line topologies.
When configuring the network, it is necessary to observe the
following boundary conditions:
• Length of the TP cable between the network and
SCALANCE X-200RNA:
- Max. 100 m with IE FC cable and IE FC RJ45 Plug 180
- Max. 10 m using patches with TP cord
• Length of the optical cables between the network and
SCALANCE X-200RNA
- Max. 5 000 m with Industrial Ethernet glass fiber-optic
cables (multimode)
- Max. 26 000 m with Industrial Ethernet glass fiber-optic
cables (singlemode)
• IP address:
The IP address is assigned by means of the DHCP (Dynamic
Host Configuration Protocol). If there is no corresponding
server in the network, the IP address can be assigned using
the supplied software tool PST (Primary Setup Tool).
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
■ Technical specifications
Article No. 6GK5204-0BA00-2KB2 6GK5204-0BS00-3LA3 6GK5204-0BS00-3PA3
Product-type designation SCALANCE X204RNA SCALANCE X204RNA EEC SCALANCE X204RNA EEC
Transmission rate
2 Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical
connections
• for network components 4 4 4
or terminal equipment maximum
• as combo port for network compo- - 2 2
nents or terminal equipment
Number of electrical connections
• for network components 4 2 2
• and terminal equipment
• for signaling contact 1 1 1
• for power supply 1 1 1
• for redundant power supply 2 1 1
Design of electrical/optical - SFP SFP
connections for network components
or terminal equipment
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
• for signaling contact 2-pole terminal block 3-pole terminal block
• for power supply 4-pole terminal block 3-pole terminal block 3-pole terminal block
Number of optical interfaces - 2 2
for optical waveguide at 100 Mbit/s
Design of optical interface - SFF port SFF port
for optical waveguide at 100 Mbit/s
Design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating current of signaling con- - 0.1 A 0.1 A
tacts at AC maximum
Operating voltage of signaling con- 24 V 24 V 24 V
tacts at DC rated value
Operating current of signaling con- 0.1 A 0.1 A 0.1 A
tacts at DC maximum
Supply voltage, current consump-
tion, power loss
Type of supply voltage DC - -
Supply voltage external 24 V - -
Supply voltage external
• minimum 19.2 V - -
• maximum 28.8 V - -
Product component fusing at power Yes Yes Yes
supply input
Type of fusing at input for supply volt-
age
Consumed current maximum 0.15 A 0.25 A 0.25 A
Active power loss at 24 V for DC 3.5 W 6W 6W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
2 Product function
• Port diagnostics Yes Yes Yes
• Statistics packet size Yes Yes Yes
• Statistics packet type Yes Yes Yes
• Error statistics Yes Yes Yes
Product functions DHCP
Product function DHCP client - - -
Product functions Redundancy
Product function
• Ring redundancy No No No
• Redundancy manager No No No
• Standby redundancy No No No
• High Speed Redundancy Protocol No No No
(HRP)
• Media Redundancy Protocol (MRP) No No No
• Parallel Redundancy Protocol (PRP) Yes Yes Yes
• High availability Seamless Redun- No No Yes
dancy (HSR)
• Passive listening No No No
Protocol is supported PRP Yes Yes Yes
Product functions Security
Protocol is supported SSH Yes Yes Yes
Product functions Time
Product function
• SICLOCK support No No No
Protocol is supported
• NTP No No No
• SNTP Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC - IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
- from FM FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4, EN 60079-15: 2005, II 3 G Ex nA II T4, EN 60079-15: 2005, II 3 G Ex nA II T4,
KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 508, CSA C22.2 No. 142-M1987 UL 508, CSA C22.2 No. 142-M1987
• for hazardous area of CSA and UL
• for emitted interference EN 61000-6-4:2001 (Class A) EN 61000-6-4:2001 (Class A) EN 61000-6-4:2001 (Class A)
• for interference immunity EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
Verification of suitability EN 61000-6-4:2001 EN 61000-6-4:2001 EN 61000-6-4:2001
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval Yes Yes Yes
• Railway application in accordance No No No
with EN 50155
• Railway application in accordance No No No
with EN 50124-1
• IEC 61850-3 No Yes Yes
Certificate of suitability IEEE 1613 - Yes Yes
Marine classification association
• American Bureau No No No
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) No No No
• Det Norske Veritas (DNV) No No No
• Germanische Lloyd (GL) No No No
• Lloyds Register of Shipping (LRS) No No No
• Nippon Kaiji Kyokai (NK) No No No
• Polski Rejestr Statkow (PRS) No No No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA PRP
2
SNMP access, web diagnostics
and PROFINET diagnostics, for 4-wire, shielded TP installation
connecting non-PRP-enabled termi- cable for connecting to IE
nal equipment to PRP networks; FC RJ45 outlet/IE FC RJ45 plug;
incl. operating instructions, PROFINET-compliant;
Industrial Ethernet network manual with UL approval;
and configuration software sold by the meter;
on CD-ROM; max. length 1 000 m,
with electrical and optical ports minimum order 20 m
for glass multimode fiber optic IE FC RJ45 Plug 180 2 x 2
cables up to 5 km
• SCALANCE X204RNA 6GK5204-0BA00-2KB2 RJ45 plug-in connector for
with four 100 Mbit/s RJ45 ports Industrial Ethernet with a rugged
metal enclosure and integrated
• SCALANCE X204RNA EEC 6GK5204-0BS00-3LA3 insulation displacement contacts
with two 100 Mbit/s RJ45 ports for connecting Industrial Ethernet
and two RJ45/SFP combo ports FC installation cables;
• SCALANCE X204RNA EEC 6GK5204-0BS00-3PA3 with 180° cable outlet;
with two 100 Mbit/s RJ45 ports for network components and
and two RJ45/SFP combo ports CPs/CPUs with Industrial Ethernet
with PRP or HSR support interfaces
SIMATIC NET communications 6GK7443-1RX00-0XE0 • 1 pack = 1 unit 6GK1901-1BB10-2AA0
processor CP 443-1 RNA • 1 pack = 10 units 6GK1901-1BB10-2AB0
S7 integration into bumpless, • 1 pack = 50 units 6GK1901-1BB10-2AE0
redundant network structures on SFP plug-in transceiver
the basis of the Parallel Redun- • SFP991-1 6GK5991-1AD00-8AA0
dancy Protocol (PRP) (multimode, glass, up to 3 km)
SOFTNET-IE RNA • SFP991-1LH+ 6GK5991-1AE00-8AA0
• (singlemode, glass, up to 70 km,
Software for connecting PCs to LH+)
PRP-enabled networks with inte-
grated SNMP, runtime software, • SFP991-1LD 6GK5991-1AF00-8AA0
software and electronic manual (singlemode, glass, up to 26 km)
on CD-ROM, license key on USB LC Plug MM2) 6GK1901-0RB10-2AB0
flash drive, Class A
LC Plug SM2) 6GK1901-0SB10-2AB0
SOFTNET-IE RNA V12
FO Robust Cable GP 50/125/9001) 6XV1873-2R
for 32/64-bit
Windows 7 Professional/Ultimate; FO Robust Cable GP 6XV1843-2R
for Windows 2008 Server R2; 4x9/125/9001)
for 32/64-bit
SITOP compact 24 V/0.6 A 6EP1331-5BA00
Windows 8 Professional/Enterprise;
for Windows Server 2012 1-phase power supply
German/English with wide-range input
• Single License for one installation 6GK1711-1EW12-0AA0 85 – 264 V AC/110 – 300 V DC,
stabilized output voltage 24 V,
SOFTNET-IE RNA V8.1 rated output current value 0.6 A,
for 32-bit Windows XP; slim design
German/English C-PLUG 6GK1900-0AB00
• Single License for one installation 6GK1711-1EW08-1AA0
Swap medium for simple replace-
Software Update Service 6GK1711-1EW00-3AL0 ment of devices in the event of a
fault; for storing configuration or
for 1 year with automatic extension;
engineering and application data;
requirement:
can be used for SIMATIC NET
Current software version
products with C-PLUG slots
1) Special fiber-optic cables, lengths and accessories available on request
2) Special tools and trained personnel are required for pre-assembling
glass fiber-optic cables
■ More information
Selection tools: SIMATIC NET Selection Tool:
To assist in selecting the right Industrial Ethernet switches as • Online version:
well as configuration of modular variants, the SIMATIC NET Se- http://www.siemens.com/snst
lection Tool and the TIA Selection Tool are available at: • Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
■ Design ■ Function
The SCALANCE X204RNA and X204RNA EEC network access • Connection of non-HSR-enabled terminal devices to ring-
points with rugged plastic or metal enclosure have been shaped networks
optimized for installation on a standard mounting rail and for • Transition from ring-shaped HSR networks to parallel PRP
direct wall mounting in different mounting positions. network structures
The network access points with IP20 degree of protection • Parallel data transmission by means of duplicate transmission 2
feature: in the ring network
• A 4-pole terminal block for connecting the redundant supply • Uncrossed connecting cables can be used due to
voltage (2 x 24 V DC), or a 3-pole terminal block in the case of Autocrossover function integrated in the ports
the wide-range power supply unit • Easy diagnostics using signaling contact, SNMP and Web
• A row of LEDs to indicate the status information (power, link browser
status, data exchange, power supply, signaling contact) • Fast device replacement in the event of a fault by using the
• A 2-pole or 3-pole terminal block for connecting the floating optional C-PLUG swap medium (not included in scope of
signaling contact in the corresponding voltage range supply)
• A SET button for on-site configuration of the signaling contact Network topology and network configuration
The SCALANCE X200RNA devices are available with the The SCALANCE X-200RNA switches with IP20 degree of protec-
following port types: tion are usually installed in a control cabinet together with the
• 100BaseTX, RJ45 connection; stations to be connected. They can be mixed electrically and
RJ45 port with a data rate of 100 Mbit/s, with autosensing and optically in star and line topologies.
autocrossover function for the connection of IE FC cables via When configuring the network, it is necessary to observe the
IE FC RJ45 Plug 180 up to 100 m following boundary conditions:
• 100BaseTX, combo port (RJ45, SFP slot); • Length of the TP cable between the network and
100 Mbit/s combo ports for direct connection to Industrial SCALANCE X-200RNA:
Ethernet copper cables or glass fiber-optic cables - Max. 100 m with IE FC cable and IE FC RJ45 Plug 180
(multimode/singlemode fiber-optic cable); - Max. 10 m using patches with TP cord
if the RJ45 interface of the combo port is used, the SFP slot is
deactivated, and vice versa. • Length of the optical cables between the network and
SCALANCE X-200RNA
- Max. 5 000 m with Industrial Ethernet glass fiber-optic
cables (multimode)
- Max. 26 000 m with Industrial Ethernet glass fiber-optic
cables (singlemode)
• IP address:
The IP address is assigned by means of the DHCP (Dynamic
Host Configuration Protocol). If there is no corresponding
server in the network, the IP address can be assigned using
the supplied software tool PST (Primary Setup Tool).
Commissioning and diagnostics
The SCALANCE X-200RNA Industrial Ethernet network access
points can be integrated into a network management system via
the standardized protocol SNMP (Simple Network Management
Protocol). In the event of a fault in the device, error messages
(SNMP traps) can be sent to a network system or as e-mail to a
specified network administrator.
The integral Web server enables configuration and diagnostics
settings to be made using a standard browser (e.g. port config-
uration). Statistical information can also be read out over the
Web server (e.g. port capacity utilization).
The following information is displayed on site by LEDs:
• Power
• Port status
• Data traffic
• Signaling contact
• HSR activity
The SCALANCE X-200RNA Industrial Ethernet network
access points can also be monitored using the floating signaling
contact.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
■ Integration
PRP communication
SCALANCE SCALANCE
X204RNA X204RNA
SCALANCE SCALANCE
XR-300 XR-300 EEC
HSR communication
Industrial Ethernet
SCALANCE SCALANCE
X204RNA X204RNA EEC
SCALANCE SCALANCE
X204RNA X204RNA
EEC Industrial Ethernet
Protection device
IP camera with HSR 1)
SCALANCE SCALANCE
Protection device X204RNA X204RNA
without HSR 1) EEC
G_IK10_XX_10343
PC
Environment with a
high EMC load, e.g.
Protection device
low-voltage and
IP camera with HSR 1)
high-voltage switchgear
G_IK10_XX_10344
1)
High-availability Seamless Redundancy Protocol Protection device
without HSR 1)
PC
For extended ambient
1)
High-Availability Seamless Redundancy Protocol conditions, e.g. EMC load
Ring-shaped HSR network structure with SCALANCE X-204RNA Redundant transition from ring-shaped HSR network structure to parallel
PRP network structure by means of SCALANCE X204RNA
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
■ Technical specifications
Article No. 6GK5204-0BA00-2MB2 6GK5204-0BS00-2NA3 6GK5204-0BS00-3PA3
Product-type designation SCALANCE X204RNA SCALANCE X204RNA EEC SCALANCE X204RNA EEC
Transmission rate
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 2
Interfaces
Number of electrical/optical
connections
• for network components 4 4 4
or terminal equipment maximum
• as combo port for network compo- - 2 2
nents or terminal equipment
Number of electrical connections
• for network components 4 2 2
and terminal equipment
• for signaling contact 1 1 1
• for power supply 1 1 1
• for redundant power supply 2 1 1
Design of electrical/optical - SFP SFP
connections for network components
or terminal equipment
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
• for signaling contact 2-pole terminal block 3-pole terminal block
• for power supply 4-pole terminal block 3-pole terminal block 3-pole terminal block
Number of optical interfaces - 2 2
for optical waveguide at 100 Mbit/s
Design of optical interface - SFF port SFF port
for optical waveguide at 100 Mbit/s
Design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating current of signaling - 0.1 A 0.1 A
contacts at AC maximum
Operating voltage of signaling 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC - -
Supply voltage external 24 V - -
• minimum 19.2 V - -
• maximum 28.8 V - -
Product component fusing Yes Yes Yes
at power supply input
Type of fusing at input
for supply voltage
Consumed current maximum 0.15 A 0.25 A 0.25 A
Active power loss at 24 V for DC 3.5 W 6W 6W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
2 Ambient temperature
• during operating -40 … +60 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C
• Comment - A maximum operating temperature A maximum operating temperature
of +85 °C is permissible for a duration of +85 °C is permissible for a duration
of 16 hours of 16 hours
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP20 IP20 IP20
Design, dimensions and weight
Design compact compact compact
Width 45 mm 70 mm 70 mm
Height 100 mm 147 mm 147 mm
Depth 87 mm 123 mm 123 mm
Net weight 0.23 kg 0.78 kg 0.78 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes
• wall mounting Yes No No
• S7-300 rail mounting No No No
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 No No No
• SMTP server - - -
• Port mirroring No No No
• for IRT PROFINET IO switch No No No
• PROFINET IO diagnosis No No No
• switch-managed No No No
Protocol is supported
• Telnet No No No
• HTTP Yes Yes Yes
• HTTPS Yes Yes Yes
• TFTP No No No
• FTP No No No
• BOOTP No No No
• SNMP v1 Yes Yes Yes
• SNMP v2 Yes Yes Yes
• SNMP v3 Yes Yes Yes
• DCP No No No
• LLDP No No No
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes
• I&M1 - higher level Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X204RNA HSR
SCALANCE X-200RNA HSR Industrial Ethernet network access points SFP plug-in transceiver
Industrial Ethernet network access • SFP991-1 6GK5991-1AD00-8AA0
points with integrated SNMP (multimode, glass, up to 3 km)
2
access, web diagnostics and • SFP991-1LH+ 6GK5991-1AE00-8AA0
PROFINET diagnostics, (singlemode, glass, up to 70 km,
for connecting non-HSR-enabled LH+)
terminal devices to ring-shaped • SFP991-1LD 6GK5991-1AF00-8AA0
HSR networks; (singlemode, glass, up to 26 km)
incl. operating instructions,
Industrial Ethernet network manual, LC Plug MM2) 6GK1901-0RB10-2AB0
and configuration software LC Plug SM2) 6GK1901-0SB10-2AB0
on CD-ROM;
with electrical and optical ports FO Robust Cable GP 50/125/9001) 6XV1873-2R
for glass multimode fiber optic
FO Robust Cable GP 6XV1843-2R
cables up to 5 km
4x9/125/9001)
• SCALANCE X204RNA 6GK5204-0BA00-2MB2
with four 100 Mbit/s RJ45 ports SITOP compact 24 V/0.6 A 6EP1331-5BA00
• SCALANCE X204RNA EEC 6GK5204-0BS00-2NA3 1-phase power supply
with two 100 Mbit/s RJ45 ports with wide-range input
and two RJ45/SFP combo ports 85 – 264 V AC/110 – 300 V DC,
• SCALANCE X204RNA EEC 6GK5204-0BS00-3PA3 stabilized output voltage 24 V,
with two 100 Mbit/s RJ45 ports rated output current value 0.6 A,
and two RJ45/SFP combo ports slim design
with PRP or HSR support
C-PLUG 6GK1900-0AB00
Accessories
Swap medium for simple
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10 replacement of devices in the
(Type A) event of a fault;
for storing configuration or
4-wire, shielded TP installation
engineering and application data;
cable for connecting to
can be used for SIMATIC NET
IE FC RJ45 outlet/IE FC RJ45 plug;
products with C-PLUG slots
PROFINET-compliant;
with UL approval;
sold by the meter;
max. length 1 000 m,
minimum order 20 m
IE FC RJ45 Plug 180 2 x 2
RJ45 plug-in connector for
Industrial Ethernet with a rugged
metal enclosure and integrated
insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables;
with 180° cable outlet;
for network components and
CPs/CPUs with Industrial Ethernet
interfaces
• 1 pack = 1 unit 6GK1901-1BB10-2AA0
• 1 pack = 10 units 6GK1901-1BB10-2AB0
• 1 pack = 50 units 6GK1901-1BB10-2AE0
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required for pre-assembling
glass fiber-optic cables
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
■ Overview
PRO
PRO
PRO
device
Type of
● applies
● applies
X204IRT
X204IRT
X204IRT
XF204IRT
XF204IRT
X202-2IRT
X202-2IRT
X202-2P IRT
X202-2P IRT
X201-3P IRT
X201-3P IRT
X200-4P IRT
X202-2P IRT
X201-3P IRT
X200-4P IRT
X204IRT PRO
Type of device
Security Integrated (Firewall/VPN)
●
●
●
●
●
●
●
●
●
PROFINET diagnosis
Software
●
●
●
●
●
●
●
●
●
Topology support (LLDP) Connection to S7 backplane bus
●
●
●
●
●
●
●
●
●
Command Line Interface / Telnet
Format module S7
Hardware
●
●
●
●
●
●
●
●
●
Web based Management
●
●
●
●
●
●
●
●
●
Configuration with STEP 7 PC module
●
●
●
●
●
●
●
●
●
SNMP
Flat type of construction
●
●
●
●
●
●
●
●
●
Ring redundancy incl. RM-functionality
●
●
●
●
●
●
●
●
●
Standby redundancy
●
●
●
●
●
●
●
●
●
IRT capability
VLAN (Virtual Local Area Network) 19“ type of construction
●
●
●
●
●
●
●
●
Rugged, compact housing
STP/ RSTP (Spanning Tree Protocol/
Rapid Spanning Tree Protocol)
Modular design
●
●
●
●
●
●
●
●
●
Passive Listening
© Siemens AG 2014
10 Gigabit Ethernet
IGMP Snooping/Querier (Internet Group
Management Protocol)
Gigabit Ethernet
GMRP (Generic Multicast Protocol)
Broadcast/ Multicast/ Unicast Limiter PoE (Power over Ethernet)
Broadcast blocking
●
●
●
●
●
●
●
●
LED diagnosis
DHCP Option 82 (Dynamic Host
Configuration Protocol)
●
●
●
●
●
●
●
●
●
SIMATIC environment
IP Access List
Access Control List (MAC)
●
●
●
●
●
●
●
●
●
Static Routing
●
●
●
●
●
●
●
●
●
Signal contact
RIPv2 (Dynamic Routing)
Siemens IK PI · 2015
●
●
●
●
●
●
●
●
●
G_IK10_XX_10315 G_IK10_XX_10314
2/227
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Overview
Product versions
SCALANCE X204IRT
• For configuring electrical Industrial Ethernet linear bus, star or
2 ring topologies with 4 electrical ports
SCALANCE X202-2IRT
• For configuring electrical/optical Industrial Ethernet linear bus,
star or ring topologies with two electrical ports and two glass
fiber optic ports
SCALANCE X202-2P IRT
• For configuring electrical/optical Industrial Ethernet linear bus,
star or ring topologies with two electrical ports and two optical
POF fiber optic ports
SCALANCE X201-3P IRT
• For configuring electrical/optical Industrial Ethernet linear bus,
star or ring topologies with one electrical port and three optical
POF fiber optic ports
SCALANCE X-200IRT switches are especially designed for SCALANCE X200-4P IRT
constructing isochronous real-time (IRT) Industrial Ethernet • For configuring optical Industrial Ethernet linear bus, star or
networks in line, star and ring topologies at transmission rates of ring topologies with 4 optical POF fiber-optic ports
10/100 Mbit/s (Redundancy Manager integrated); construction
of redundant ring connections possible. SCALANCE X204 IRT PRO
• Optimized performance due to combination of the switching • For the construction of electrical Industrial Ethernet linear, star
mechanisms "Cut Through" and "Store and Forward" or ring topologies with four electrical ports in degree of
• Fast media redundancy due to the integrated redundancy protection IP65/67 with PROFINET-compliant push-pull
manager for Fast Ethernet connection technology
• Rugged, industry-standard station connections with SCALANCE X202-2P IRT PRO
PROFINET-compatible plug-in connectors that offer additional • For the construction of electrical/optical Industrial Ethernet
strain relief and bending strain relief thanks to latching on the linear bus, star or ring structures with two electrical and two
enclosure optical POF/PCF fiber optic ports in degree of protection
• PROFINET diagnostics, SNMP access, integrated web server IP65/67 with PROFINET-compliant push-pull connection
and automatic e-mail transmission function for remote technology
diagnostics and signaling via the network SCALANCE X201-3P IRT PRO
• Different device versions with copper and fiber-optic inter- • For the construction of electrical/optical Industrial Ethernet
faces (BFOC, SC RJ) linear bus, star or ring topologies with one electrical and three
• Implementation of cabinet-free plant concepts with optical POF/PCF fiber optic ports in degree of protection
PROFINET-compliant push pull connection systems with IP65/67 with PROFINET-compliant push-pull connection
device variants with IP65/67 protection technology
Applicable to all versions:
• Integral redundancy manager (RM)
• Device diagnostics with LEDs (power, link status, data
communication)
• Remote diagnosis is possible through signaling contact
(signal mask can be set locally using buttons), PROFINET,
SNMP and Web browser
• Automatic e-mail send function
• Rugged, industry-standard station connections with
PROFINET-compatible RJ45 connectors that offer additional
strain relief and bending strain relief thanks to latching on
the housing
The SCALANCE X-200IRT switches, based on PROFINET,
satisfy the real-time requirements of the field level up to high-
performance motion control applications.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Benefits ■ Design
• The SCALANCE X-200IRT switches in a rugged metal housing
with IP30 and IP65/67 degree of protection are optimized for
mounting on a standard rail and an S7-300 rail. Direct wall
mounting in various positions is also possible. Thanks to the
• The ideal solution for constructing isochronous real-time (IRT)
Industrial Ethernet segments especially in line, star and ring
S7-300 housing dimensions, the devices are suitable for
integration into an automation solution with S7-300 compo- 2
topologies with copper and fiber-optic cabling (glass FOC, nents.
PCF FOC, POF FOC) • The switches have a 4-pin terminal block for connecting the
• Reliable data communication thanks to rugged, industry- redundant supply voltage (2 x 24 V DC). The variants with
standard device connection using PROFINET-compatible IP65/67 protection have two 5-pin push-pull connectors via
connectors (IE FC RJ45 Plug 2x2) that offer additional strain which the supply voltage is fed and forwarded. In addition, the
relief and bending strain relief thanks to latching on the load voltage circuit is also looped through for the ET200pro
enclosure devices further along the line. The devices with IP65/67
protection thus have no redundant voltage feed, but permit
• High network availability in ring topologies, without reconfigu-
optimal integration into cabinet-free plant concepts with
ration times, when using the PROFINET-compliant MRPD
ET200pro modules.
process (Media Redundancy for Planned Duplication
The status information (power, link status, data traffic, voltage
according to IEC 61158)
supply, signaling contact) is indicated by means of a row of
• Fast and easy diagnosis with LEDs on the device, through the LEDs.
integral Web server and through signaling contacts
The SCALANCE X-200IRT modules are available with the follow-
• Easy integration in the process diagnosis and system ing port types:
diagnosis with PROFINET
• 10/100BaseTX, RJ45 connection
• Configuration and diagnostics integrated into STEP 7 provide RJ45 port, automatic detection of the data rate (10 or
significant benefits during the engineering, start-up and 100 Mbit/s), with Autosensing and Autocrossover function for
operating phases of a plant connecting IE FC cables over IE FC RJ45 Plug 180 over
• Module replacement without the need for a programming distances up to 100 m.
device, using the C-PLUG swap media for backing up the • 10/100BaseTX, push-pull RJ45 connection
configuration data RJ45 port, automatic detection of the data rate (10 or
100 Mbit/s), with Autosensing and Autocrossover function for
■ Application connecting IE FC cables via IE FC RJ45 Plug PRO over
distances up to 100 m
The SCALANCE X-200IRT Industrial Ethernet switches permit
the construction of isochronous real-time (IRT) Industrial Ether- • 100BaseFX, BFOC connection technique
net line and star topologies. Ring structures can also be de- BFOC ports for direct connection to Industrial Ethernet glass
signed using the integral redundancy manager (RM). Redun- fiber-optic cables up to 5000 m for configuring line and star
dant ring connections are also possible. Thanks to innovative topologies.
switching technology, the special requirements of automation • 100BaseFX, SC RJ connections
with regard to line topology, isochronous mode for motion control SC RJ ports for connection to Industrial Ethernet POF (50 m)
applications and unlimited IT openness have been satisfied for and PCF FOC (100 m) using SC RJ plug connectors
the first time within a single technology based on the PROFINET • 100BaseFX, push-pull SC RJ connections
standard. SC RJ ports for connection to Industrial Ethernet POF (50 m)
The switches with IP30 degree of protection have been de- and PCF FOC (100 m) using SC RJ plug PRO connectors
signed for use in the control cabinet. The switches with IP65/67
protection are designed for cabinet-free mounting (PROFINET-
compliant push pull connection technology).
Real-time Ethernet
• Interfacing of the PROFINET IO Devices to the PROFINET IO
Controller through high-performance, optimized data trans-
mission
• Coexistence of isochronous mode for motion control applica-
tions and IT openness:
Reaction-free transmission of real-time and non-real-time
communication on the same line
Additionally through isochronous real-time (IRT) Ethernet
• Isochronous real-time communication based on the trans-
mission procedure of the IEEE 802 standard by combining the
switching mechanisms "Cut Through" and "Store and Forward"
• For drive controls, PROFINET with isochronous real-time is the
best performing system worldwide with regard to its isochron-
ronous and deterministic response.
With a cycle time of 1 ms, for example, axes can be controlled
in isochronous mode whereby 50% of the bandwidth is
available solely for IT communication.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Function
• 4-port switch for configuring electrical and optical Industrial Commissioning and diagnostics
Ethernet line, star and ring topologies
PROFINET diagnostic alarms from SCALANCE X-200IRT
• Integral redundancy manager for design of ring topologies Switches can be displayed with the appropriate SIMATIC
2 • Integral standby function for redundant coupling of two rings Engineering Tools and processed in the control unit. The engi-
• Extremely short cycle times with highly accurate clock-pulse neering outlay for the PLC and HMI have been drastically re-
rates thanks to integrated real-time functions duced due to the complete integration in the SIMATIC concept
for system error messages.
• Bumpless ring redundancy by sending message frames twice
in the ring, by means of PROFINET-compliant MRPD The SCALANCE X-200IRT Industrial Ethernet switches can also
procedure (Media Redundancy for Planned Duplication be integrated into a network management system through the
according to IEC 61158) standardized protocol SNMP (Simple Network Management
Protocol). In the event of a device fault, error messages (SNMP
• System-wide clock accuracy (less than 1 ms) traps) can be sent to a network system or as e-mail to a specified
• Uncrossed connecting cables can be used due to network manager.
Autocrossover function integrated in the ports
The integral Web server enables configuration and diagnosis
• Load disconnection through integral switch functionality settings to be made using a standard browser. Statistical infor-
• Easy diagnostics using signaling contact, SNMP and Web mation can also be read out over the Web server. Warning
browser thresholds, and alarms generated by them, permit early recog-
• Automatic e-mail function nition of critical fiber states (only with POF). Cable failures (fiber
breakage) can thus be avoided, and plant downtimes reduced,
• Integration into the diagnostics of a PROFINET IO-Controllers since maintenance work can be carried out at an early point in
for a consistent diagnostics concept, including network time and outside production periods.
infrastructure
• Fast device replacement in the event of a fault by using the The following information is displayed on site by LEDs:
optional C-PLUG swap medium (not included in scope of • Power
supply) • Port status
Network topology and network configuration • Data traffic
The SCALANCE X-200IRT Industrial Ethernet Switches are • RM activated
usually installed in the control cabinet together with the stations • POF cable diagnostics (for POF versions only)
to be connected (e.g. ET 200S) or, in the case of cabinet-free
designs, mounted directly onto the machine. When configuring The Industrial Ethernet switches of the SCALANCE X-200IRT line
the network, it is necessary to observe the following boundary can also be monitored using the floating signaling contact.
conditions:
• Length of the TP cable between two SCALANCE X switches: PROFINET
- Max. 100 m with IE FC cable and IE FC RJ45 Plug 180 or
IE FC RJ45 Plug PRO Industrial
- Max. 10 m with TP Cord Ethernet
• Length of the optical cables
- Max. 4 000 m with Industrial Ethernet glass fiber-optic PC with CP 1616
cables (62.5/125 µm) as PN IO controller
- Max. 5 000 m with Industrial Ethernet glass fiber-optic
cables (50/125 µm)
- Max. 100 m with Industrial Ethernet PCF fiber-optic cables.
- Max. 50 m with Industrial Ethernet POF fiber-optic cables. Field PG
SCALANCE
• IP Address: SCALANCE X204IRT
The IP address is assigned by means of the DHCP (Dynamic X204IRT
Host Configuration Protocol). If there is no corresponding
server in the network, the IP address can be assigned using
the supplied software tool PST (Primary Setup Tool) or STEP 7.
The SCALANCE X-200IRT switches and their real-time
functions are configured with STEP 7.
G_IK10_XX_10100
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Function (continued)
S7-400
PC
ET 200S ET 200S 2
Switch
SCALANCE
X202-2IRT
PC
S7-400
Industrial Ethernet
Switch Switch
S7-300 SCALANCE SCALANCE IPC
X202-2IRT X202-2IRT
S7-300 ET 200S
G_IK10_XX_10102
Configuration with high-speed redundancy in the optical ring
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Function (continued)
Operator Station Operator Stations
S7-300
SCALANCE SCALANCE
X204IRT X208
100 Mbit/s
IPC
G_IK10_XX_10173
S7-1500
l{GYWWzG
wyvmpul{ plGG wvmTmvj ptGX\XTZGwuGmv
pGl
zjhshujl zjhshujl zjhshujl
YW[py{ YWYTYwGpy{ YWWT[wGpy{
l{GYWWzG
ptGX\XTZGwuGmv
nprXWXWX^]
l{GYWWzGGptGX\XTZGwuG
Mixed network topology with plastic fiber-optic cables and twisted-pair cables
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
■ Technical specifications
Article No. 6GK5200-4AH00-2BA3 6GK5201-3BH00-2BA3 6GK5202-2BH00-2BA3
Product-type designation SCALANCE X200-4P IRT SCALANCE X201-3P IRT SCALANCE X202-2P IRT
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 2
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s
Interfaces
Number of electrical/optical
connections
• for network components 4 4 4
or terminal equipment maximum
Number of electrical connections
• for network components - 1 2
and terminal equipment
• for signaling contact 1 1 1
• for power supply 1 1 1
• for redundant power supply 1 1 1
Design of electrical/optical SC RJ SC RJ SC RJ
connections for network components
or terminal equipment
Design of electrical connection
• for network components - RJ45 port RJ45 port
and terminal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces 4 3 2
for optical waveguide at 100 Mbit/s
Design of optical interface SC-RJ/POF port SC-RJ/POF port SC-RJ/POF port
for optical waveguide at 100 Mbit/s
Connectable optical power relative
to 1 mW
• of the transmitter output -8 ... -2 dB -8 ... -2 dB -8 ... -2 dB
Optical sensitivity relative to 1 mW -25 dB -25 dB -25 dB
of the receiver input minimum
Attenuation of fiber-optic cable 0 dB 0 dB 0 dB
transmission link minimum necessary
Range at the optical interface 0 … 0.05 km 0 … 0.05 km 0 … 0.05 km
depending on the optical fiber used
Design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC
Supply voltage external 24 V 24 V 24 V
• minimum 18 V 18 V 18 V
• maximum 32 V 32 V 32 V
Product component fusing Yes Yes Yes
at power supply input
Type of fusing at input 1.1 A / 33 V 1.1 A / 33 V 1.1 A / 33 V
for supply voltage
Consumed current maximum 0.4 A 0.35 A 0.3 A
Active power loss at 24 V for DC 9.6 W 8.4 W 7.2 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
2 Ambient temperature
• during operating -25 … +40 °C -25 … +50 °C -25 … +60 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP30 IP30 IP30
Design, dimensions and weight
Design compact compact compact
Width 60 mm 60 mm 60 mm
Height 125 mm 125 mm 125 mm
Depth 124 mm 124 mm 124 mm
Net weight 0.78 kg 0.78 kg 0.78 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes
• wall mounting Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes
Product properties, functions,
components general
Cascading in the case of a 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on signal Any (depending only on signal Any (depending only on signal
of star structuring propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes
• SMTP server - - -
• Port mirroring No No No
• for IRT PROFINET IO switch Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes
• switch-managed Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes
• HTTP Yes Yes Yes
• HTTPS Yes Yes Yes
• TFTP Yes Yes Yes
• FTP Yes Yes Yes
• BOOTP No No No
• SNMP v1 Yes Yes Yes
• SNMP v2 Yes Yes Yes
• SNMP v3 Yes Yes Yes
• DCP Yes Yes Yes
• LLDP Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes
• I&M1 - higher level Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
2 Product function
• Port diagnostics Yes Yes
• Statistics packet size Yes Yes
• Statistics packet type Yes Yes
• Error statistics Yes Yes
Product functions DHCP
Product function DHCP client Yes Yes
Product functions Redundancy
Product function
• Ring redundancy Yes Yes
• Redundancy manager Yes Yes
• Standby redundancy Yes Yes
• High Speed Redundancy Protocol Yes Yes
(HRP)
• Media Redundancy Protocol Yes Yes
(MRP)
• Parallel Redundancy Protocol No No
(PRP)
• Passive listening Yes Yes
Protocol is supported PRP Yes Yes
Product functions Security
Protocol is supported SSH Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes
Protocol is supported
• NTP No No
• SNTP Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1,
Zone 2, GP. IIC, T4 Zone 2, GP. IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-15: 2005, EN 60079-0 : 2006, EN 60079-15: 2005,
II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 /
Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4
• for emitted interference EN 61000-6-4:2001 (Class A) EN 61000-6-4:2001 (Class A)
• for interference immunity EN 61000-6-4:2001 EN 61000-6-4:2001
Verification of suitability EN 61000-6-4:2001 EN 61000-6-4:2001
• CE mark Yes Yes
• C-Tick Yes Yes
• KC approval Yes Yes
• Railway application in accordance No No
with EN 50155
• Railway application in accordance No No
with EN 50124-1
Marine classification association
• American Bureau Yes Yes
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) No Yes
• Det Norske Veritas (DNV) Yes Yes
• Germanische Lloyd (GL) Yes Yes
• Lloyds Register of Shipping (LRS) Yes Yes
• Nippon Kaiji Kyokai (NK) Yes Yes
• Polski Rejestr Statkow (PRS) No No
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
2 Ambient temperature
• during operating -25 … +70 °C -25 … +60 °C -25 … +60 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C
• Comment - - -
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP67 IP67 IP67
Design, dimensions and weight
Design compact compact compact
Width 90 mm 90 mm 90 mm
Height 125 mm 125 mm 125 mm
Depth 124 mm 124 mm 124 mm
Net weight 1 kg 1 kg 1 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes
• wall-mounting Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes
Product properties, functions,
components general
Cascading in the case of a 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases of star structuring Any (depending only on signal Any (depending only on signal Any (depending only on signal
propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based Management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes
• Port mirroring No No No
• for IRT PROFINET IO switch Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes
• switch-managed Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes
• HTTP Yes Yes Yes
• HTTPS Yes Yes Yes
• TFTP Yes Yes Yes
• FTP Yes Yes Yes
• BOOTP No No No
• SNMP v1 Yes Yes Yes
• SNMP v2 Yes Yes Yes
• SNMP v3 Yes Yes Yes
• DCP Yes Yes Yes
• LLDP Yes Yes Yes
Identification & maintenance function
• I&M0 - device specific information Yes Yes Yes
• I&M1 - higher level Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
Industrial Ethernet Switches SCALANCE X-200IRT POF Standard Cable GP 980/1000 6XV1874-2A
Managed Industrial Ethernet POF standard cable for fixed
switches; routing indoors with PVC sheath;
2
Isochronous Real-Time, sold by the meter
LED diagnostics, max. length 1 000 m;
fault signaling contact with minimum order 20 m
SET button,
redundant power supply; PCF Standard Cable GP 200/230 6XV1861-2A
incl. operating instructions, Standard cable, segmentable,
Industrial Ethernet network manual sold by the meter;
and configuration software max. length 2 000 m;
on CD-ROM minimum order 20 m;
• SCALANCE X204IRT; 6GK5204-0BA00-2BA3
4 x 10/100 Mbit/s RJ45 ports IE FC RJ45 Plug 180 2 x 2
• SCALANCE X204IRT PRO; 6GK5204-0JA00-2BA6 RJ45 plug-in connector for
4 x 10/100 Mbit/s Industrial Ethernet with a rugged
RJ45 push-pull ports metal enclosure and integrated
• SCALANCE X202-2IRT; 6GK5202-2BB00-2BA3 insulation displacement contacts
2 x 10/100 Mbit/s RJ45 ports, for connecting Industrial Ethernet
2 x 100 Mbit/s FC installation cables;
• Multimode BFOC ports with 180° cable outlet;
• SCALANCE X202-2P IRT; 6GK5202-2BH00-2BA3 for network components and
2 x 10/100 Mbit/s RJ45 ports, CPs/CPUs with Industrial Ethernet
2 x 100 Mbit/s interface
POF/PCF SC RJ ports • 1 pack = 1 unit 6GK1901-1BB10-2AA0
• SCALANCE X202-2P IRT PRO; 6GK5202-2JR00-2BA6 • 1 pack = 10 units 6GK1901-1BB10-2AB0
2 x 10/100 Mbit/s • 1 pack = 50 units 6GK1901-1BB10-2AE0
• RJ45 push-pull ports,
2 x 100 Mbit/s IE FC RJ45 Plug PRO 6GK1901-1BB20-6AA0
POF/PCF SC RJ push-pull ports FastConnect RJ45 plug-in
• SCALANCE X201-3P IRT; 6GK5201-3BH00-2BA3 connector; plastic housing,
1 x 10/100 Mbit/s RJ45 port, insulation displacement technology,
3 x 100 Mbit/s for SCALANCE X-200IRT PRO
POF/PCF SC RJ ports switches and SIMATIC ET 200pro;
• SCALANCE X201-3P IRT; 6GK5201-3JR00-2BA6 1 connector (IP65/67)
1 x 10/100 Mbit/s RJ45 port, suitable for on-site assembly
3 x 100 Mbit/s SC RJ POF Plug 6GK1900-0MB00-0AC0
POF/PCF SC RJ ports
• SCALANCE X200-4P IRT; 6GK5200-4AH00-2BA3 20 plugs for on-site assembly
4 x 100 Mbit/s POF/PCF SC RJ
SC RJ POF Plug PRO 6GK1900-0MB00-6AA0
Accessories
1 plug (IP65/67)
Industrial Ethernet media for on-site assembly
converter SCALANCE X-100
SC RJ PCF Plug 6GK1900-0NB00-0AC0
Industrial Ethernet media convert-
10 plugs for on-site assembly
ers, LED diagnostics, fault signaling
contact with SET key, redundant SC RJ PCF Plug PRO 6GK1900-0NB00-6AA0
power supply, PROFINET-compati-
ble securing collars 1 plug (IP65/67)
for on-site assembly
• SCALANCE X101-1POF; 6GK5101-1BH00-2AA3
1 X 10/100 Mbit/s RJ45 port, Termination Kit 6GK1900-0ML00-0AA0
1 X 100 Mbit/s POF SC RJ port SC RJ POF Plug
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10 Assembly case for on-site installa-
(Type A) tion of SC RJ POF connectors;
consisting of stripping tool,
4-core, shielded TP installation
Kevlar cutters,
cable for connection to
SC RJ grinding plate,
IE FC RJ45 outlet / IE FC RJ45 plug;
grinding paper,
PROFINET-compliant;
grinding base and microscope
with UL approval;
sold by the meter; Termination Kit 6GK1900-0NL00-0AA0
max. length 1 000 m, SC RJ PCF Plug
minimum order 20 m
Assembly case for local assembly
FO Standard Cable GP 50/125/ of SC RJ PCF connectors,
1400 1) 2) comprising a stripping tool,
buffer stripping tool, Kevlar cutters,
Multimode cable, 6XV1873-2A
fiber breaking tool and microscope
sold by the meter;
max. length 1 000 m;
minimum order 20 m;
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required for pre-assembling
glass fiber-optic cables
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200IRT managed
■ Overview ■ Application
The SCALANCE XF204IRT Industrial Ethernet switch permits the
construction of isochronous real-time (IRT) Industrial Ethernet
line and star topologies. Thanks to innovative switching technol-
ogy, the special requirements of automation with regard to line
2 topology, isochronous mode for motion control applications, and
unlimited IT openness are satisfied within a single technology
based on the PROFINET standard.
Features:
• Device diagnostics with LEDs (power, link status, data
communication)
• Remote diagnostics is possible through signaling contact
(signal mask can be set locally using buttons), PROFINET,
SNMP, and web browser
• Automatic e-mail send function
• The RJ45 sockets are designed to be industry-compatible
with additional sleeves, for connection of the
IE FC RJ45 Plug 180
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200IRT managed
G_IK10_XX_10256
Mbit/s), with Autosensing and Autocrossover functions for
connecting IE FC cables using the IE FC RJ45 Plug 180.
■ Function
• Configuration of electrical Industrial Ethernet line, star and SCALANCE XF204IRT with ET 200S and SIMATIC Microbox
ring topologies in compact control cabinets or boxes
• Integral redundancy manager for setting up ring topologies
• Integral standby function for redundant coupling of two rings Commissioning and diagnosis
• Extremely short cycle times with highly accurate clock-pulse PROFINET diagnostic interrupts from SCALANCE XF204IRT can
rates thanks to integrated real-time functions be displayed with the appropriate SIMATIC Engineering Tools
and processed in the controller with expanded diagnostics
• Bumpless ring redundancy by sending message frames twice
function. The engineering outlay for the PLC and HMI have been
in the ring, by means of PROFINET-compliant MRPD
drastically reduced due to the complete integration in the
procedure (Media Redundancy for Planned Duplication
SIMATIC concept for system error messages.
according to IEC 61158)
• System-wide clock accuracy (deviation less than 1 ms) The SCALANCE XF204IRT Industrial Ethernet switch can also be
integrated into a network management system, e.g. SINEMA
• Uncrossed connecting cables can be used due to Server, through the standardized Simple Network Management
Autocrossover function integrated in the ports Protocol (SNMP). In the event of a fault in the device, error mes-
• Easy diagnostics using signaling contact, SNMP and Web sages (SNMP traps) can be sent to a network system or as e-
browser mail to a specified network administrator.
• Integration into the diagnostics of a PROFINET IO Controller The integral Web server enables configuration and diagnostics
by means of real-time communication (RT) according to the settings to be made using a standard browser (e.g. port con-
PROFINET standard figuration). Statistical information can also be read out over the
• Fast device replacement in the event of a fault by using the Web server (e.g. port capacity utilization).
optional C-PLUG swap medium (not included in scope of
The following information is displayed by LEDs on site:
supply)
• Power
Network topology and network configuration
• Port status
The SCALANCE XF204IRT Industrial Ethernet switch with IP30 • Data traffic
degree of protection is installed in a control cabinet together with
the stations to be connected. It can be combined electrically in • Signaling contact
star, line and ring topologies. • Redundancy manager function
When configuring the network, it is necessary to observe the
following boundary conditions:
• Length of the TP cable between two SCALANCE XF switches:
- Max. 100 m with IE FC cable and IE FC RJ45 Plug 180
• IP Address:
The IP address is assigned using the DHCP (Dynamic Host
Configuration Protocol) mechanism. If there is no corre-
sponding server in the network, the IP address can be
assigned using the supplied software tool PST (Primary Setup
Tool) or STEP 7. The device and real-time configuration of the
SCALANCE XF204IRT switch is performed via STEP 7.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200IRT managed
■ Technical specifications
Article No. 6GK5204-0BA00-2BF2 Article No. 6GK5204-0BA00-2BF2
Product-type designation SCALANCE XF204IRT Product-type designation SCALANCE XF204IRT
Transmission rate Permitted ambient conditions
2 Transfer rate 1 10 Mbit/s Ambient temperature
• during operating -40 … +60 °C
Transfer rate 2 100 Mbit/s
• during storage -40 … +60 °C
Interfaces • during transport -40 … +60 °C
Number of electrical/optical • Comment If the IE switch XF 200 is installed
connections horizontally a maximum ambient
• for network components 4 temperature of +40 °C is permitted
or terminal equipment maximum Relative humidity at 25 °C without 95 %
Number of electrical connections condensation during operating
• for network components and 4 maximum
terminal equipment Protection class IP IP20
• for signaling contact 1
Design, dimensions and weight
• for power supply 1
• for redundant power supply 1 Design Flat
Design of electrical connection Width 75 mm
• for network components RJ45 port Height 125 mm
and terminal equipment Depth 73 mm
• for signaling contact 2-pole terminal block Net weight 0.25 kg
• for power supply 4-pole terminal block
Mounting type
Design of the removable storage Yes • 35 mm DIN rail mounting Yes
C-PLUG
• wall mounting No
Signal-Inputs/outputs • S7-300 rail mounting No
Operating voltage of signaling 24 V Product properties, functions,
contacts at DC rated value components general
Operating current of signaling 0.1 A Cascading in the case of a 50
contacts at DC maximum redundant ring at reconfiguration time
Supply voltage, of < 0.3 s
current consumption, power loss Cascading in cases Any (depending only on signal
Type of supply voltage DC of star structuring propagation time)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XF-200IRT managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Overview
Hardware
SIMATIC environment
10 Gigabit Ethernet
Format module S7
Gigabit Ethernet
Modular design
LED diagnosis
Signal contact
PC module
PLUG slot
Type of device
SCALANCE X-300
X302-7EEC ● ● ● ● ● ● ● ●
X304-2FE ● ● ● ● ● ● ●
X306-1LD FE ● ● ● ● ● ● ●
X307-2EEC ● ● ● ● ● ● ● ●
X307-3 ● ● ● ● ● ● ● ●
X307-3LD ● ● ● ● ● ● ● ●
X308-2 ● ● ● ● ● ● ● ●
X308-2LD ● ● ● ● ● ● ● ●
X308-2LH ● ● ● ● ● ● ● ●
X308-2LH+ ● ● ● ● ● ● ● ●
X308-2M ● ● ● ● ● ● ● ● ●
X308-2M PoE ● ● ● ● ● ● ● ● ● ●
X308-2M TS ● ● ● ● ● ● ● ● ●
X310 ● ● ● ● ● ● ● ●
X310FE ● ● ● ● ● ● ●
X320-1FE ● ● ● ● ● ● ●
X320-3LD FE ● ● ● ● ● ● ●
XR324-12M ● ● ● ● ● ● ● ● ●
XR324-4M PoE ● ● ● ● ● ● ● ● ● ●
XR324-4M EEC ● ● ● ● ● ● ● ● ●
XR324-4M PoE TS ● ● ● ● ● ● ● ● ● ●
XR324-12M TS ● ● ● ● ● ● ● ● ●
● applies
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Overview (continued)
Software
Redundancy Protocol)
IEEE 802.1x (Radius)
PROFINET diagnosis
Standby redundancy
Broadcast blocking
Passive Listening
Link Aggregation
Static Routing
IRT capability
SNMP
Type of
device
X302-7EEC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
SCALANCE X-300
X304-2FE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X306-1LD FE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X307-2EEC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X307-3 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X307-3LD ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2LD ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2LH ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2LH+ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2M ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2M PoE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X308-2M TS ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X310 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X310FE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X320-1FE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
X320-3LD FE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
XR324-12M ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
XR324-4M ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
PoE
XR324-4M ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
EEC
XR324-4M ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
PoE TS
XR324-12M ● ●
TS ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● applies
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Application
SCALANCE X-300 products enable the establishment of The main area of application is found in high-performance plant
switched networks both at the field level and at the control level networks with interfaces to the corporate network.
where high data transfer rates are required in addition to high
network availability and extensive diagnostics facilities. The X308-2M TS is suitable for use in railway applications due to
2 The switches are designed in degree of protection IP30 for
installation in control cabinets.
its specification according to EN 50155.
Product versions
Switches with Fast Ethernet and Gigabit Ethernet ports
S7-400
Operator Station PC
zjhshujl
ZXW
PROFINET
Industrial Ethernet
nprXWXWYX[
S7-400 S7-400 S7-400 S7-400
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Application (continued)
PC PC
SCALANCE
XM416-4C
SCALANCE
XM416-4C 2
S7-400
G_IK10_XX_10215
ET 200SP ET 200SP ET 200SP
PC
Fast Ethernet switches • For configuring electrical and/or optical Industrial Ethernet
line, star or ring structures
SCALANCE X310FE - SCALANCE X310FE;
SCALANCE X304-2FE 10 x 10/100 Mbit/s RJ45 ports, electrical
SCALANCE X306-1LD FE - SCALANCE X304-2FE;
SCALANCE X320-1FE 4 x 10/100 Mbit/s RJ45 ports, electrical
SCALANCE X320-3 LD FE 2 x 100 Mbit/s SC ports, optical, for glass FOC (multimode)
up to 5 km
- SCALANCE X306-1LD FE;
6 x 10/100 Mbit/s RJ45 ports, electrical
1 x 100 Mbit/s SC port, optical, for glass FOC (singlemode)
up to 26 km
- SCALANCE X320-1FE;
20 x 10/100 Mbit/s RJ45 ports, electrical
1 x 100 Mbit/s SC port, optical, for glass FOC (multimode)
up to 5 km
- SCALANCE X320-3LD FE;
20 x 10/100 Mbit/s RJ45 ports, electrical
1 x 100 Mbit/s SC port, optical, for glass FOC (multimode)
up to 5 km
2 x 100 Mbit/s SC ports, optical, for glass FOC (singlemode),
up to 26 km
• The RJ45 ports are designed to be industry-standard with
additional holding collars for connection of the
IE FC RJ45 Plug 180
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Application (continued)
S7-300 with S7-300 with S7-300 with
CP 343-1 HMI CP 343-1 HMI CP 343-1 HMI
2
SCALANCE SCALANCE SCALANCE
X320-1FE X320-1FE X320-1FE
100 Mbit/s
(singlemode)
< 26 km
SCALANCE XC100-4OBR SCALANCE XC100-4OBR SCALANCE XC100-4OBR
with X320-3LD FE with X320-3LD FE with X320-3LD FE
SCALANCE SCALANCE
X306-1LD FE X306-1LD FE
SCALANCE SCALANCE
XR324-12M XR324-12M
G_IK10_XX_10281
PROFINET/Industrial Ethernet (Twisted Pair)
PROFINET/Industrial Ethernet (Fiber Optic) PC/IPC with CP 1623
Full Gigabit switches • For setting up optical line, ring or star network structures with
- Four integrated electrical Gigabit Ethernet ports and
SCALANCE X308-2M - Four modular slots for equipping with any 2-port media
SCALANCE X308-2M TS modules (see "Media modules for SCALANCE X-300")
• Star hubs in the plant bus
(redundant connection possible)
• SCALANCE X308-2M;
4 x 10/100/1 000 Mbit/s RJ45 ports, electrical
2 x free module slots for 4 x 10/100/1 000 Mbit/s media
modules (electrical or optical)
• SCALANCE X308-2M TS (TS = Transportation Systems);
4 x 10/100/1 000 Mbit/s RJ45 ports, electrical
2 x free module slots for 4 x 10/100/1 000 Mbit/s media
modules (electrical or optical)
is suitable for use in railway applications due to its specifi-
cation according to EN 50155
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Design ■ Function
The SCALANCE X-300 Industrial Ethernet switches with rugged • Increase of the network performance;
metal housing are optimized for mounting on a standard DIN rail by filtering the data traffic on the basis of the Ethernet (MAC)
and the S7-300 rail. Direct wall mounting in various positions is address of the data terminals, data traffic remains local;
also possible. Thanks to the S7-300 housing dimensions, the only data intended for users of another subnetwork is
devices are suitable for integration into an automation solution
with S7-300 components.
forwarded by the switch.
• Simple network configuration and network expansion;
2
The switches have: the switch saves the data received at the ports and forwards
it automatically to the destination address. Collision detection
• a 4-pin terminal block for connecting the redundant power (CSMA/CD method) does not restrict the expansion of the
supply (2 x 24 V DC) network beyond the port.
• Row of LEDs for indicating the status information • Limitation of the error propagation to the affected subnetwork;
(power, link status, data traffic, fault, redundancy manager, the SCALANCE X-300 switches only forward data with a valid
standby manager) checksum (CRC).
• A 2-pin terminal block for connecting the isolated signaling • Integration of existing subnetworks with 10 Mbit/s into
contact Fast Ethernet networks with 100 Mbit/s;
• SELECT/SET key for on-site configuration of the signaling at the twisted-pair ports, the SCALANCE X-300 switch
contact automatically recognizes the conductor pairs for transmission
• Slot for optional C-PLUG swap medium on the rear of the and reception (Autocrossover), the data transfer rate of 10 or
device for easy replacement in the event of a fault 100 or 1 000 Mbit/s, as well as full-duplex and half-duplex
mode (Autonegotiation).
The SCALANCE X-300 switches are available with the following • High-performance connection of SCALANCE X-300 switches
port types: with 1 Gbit/s;
• 10/100BaseTX, RJ45 connection; SCALANCE X-300 switches have Gigabit Ethernet ports
RJ45 socket, automatic detection of the data rate for connecting the switches to each other or with other
(10 or 100 Mbit/s), with Autosensing and Autocrossover Gigabit-Ethernet-enabled components
function for the connection of IE FC cables via (e.g. SCALANCE X-400, X-500)
IE FC RJ45 Plug 180 to 100 m. • Integrated redundancy manager for constructing Fast
• 10/100/1000BaseTX, RJ45 connection; Ethernet and Gigabit Ethernet ring topologies with high-speed
RJ45 socket, automatic detection of the data rate media redundancy.
(10 or 100 or 1 000 Mbit/s), with Autosensing and • High-speed standby redundancy;
Autocrossover function for the connection of several network segments such as rings can be intercon-
- IE FC cables 2x2 for 100 Mbit/s via IE FC RJ45 Plug 180 nected redundantly with SCALANCE X-300 by means of the
up to 100 m integrated standby function. Two X-300 switches are
- IE FC cables 4x2 for 1 000 Mbit/s via TP Cord and IE FC configured in a ring as a master and slave and are connected
RJ45 Modular Outlet up to 100 m via two links to the other ring. The redundant connection can
- IE FC cables 4x2 for 1 000 Mbit/s via IE FC RJ45 Plug 4x2 be made at 1 000 Mbit/s.
up to 100 m
• Redundant interfacing to higher-level networks;
• 1000BaseSX, SC connections; SCALANCE X-300 switches support the standardized redun-
SC ports for direct connection to the Industrial Ethernet glass dancy procedures Spanning Tree Protocol (STP) and Rapid
fiber-optic cable up to 750 m (multimode) Spanning Tree Protocol (RSTP). This enables a subnetwork to
• 1000BaseSX, SC connections; be connected redundantly to a higher-level network with
SC ports for direct connection to the Industrial Ethernet reduced requirements for the reconfiguration time (in the order
glass fiber-optic cable up to 10 km (singlemode) of seconds). By supporting the Multiple Spanning Tree
• 1000BaseLX, SC connections; Protocol (MSTP), a network can also be split into multiple
SC ports for direct connection to the Industrial Ethernet sub-segments.
glass fiber-optic cable up to 40 km (singlemode) • Support of virtual networks (VLAN);
• 1000BaseLX, SC connections; for structuring Industrial Ethernet networks with a fast growing
SC ports for direct connection to the Industrial Ethernet number of users, a physically existing network can be divided
glass fiber-optic cable up to 70 km (singlemode) into several virtual networks.
• Load limiting when multicast protocols (e.g. video trans-
mission) are used;
through learning the multicast sources and targets (IGMP
Snooping, IGMP Querier), SCALANCE X-300 switches can
also filter multicast data traffic and therefore limit the load in
the network.
• Configuration of the ports for terminals that support authenti-
cation in accordance with IEEE 802.1x. Authentication is by
means of a RADIUS server that must be configured appropri-
ately and must be accessible via the network.
• Support of the DHCP Option 82, 66, 67
(Dynamic Host Configuration Protocol);
this facilitates the IP address assignment of a terminal
depending on the connected switch port. The IP address is
assigned via a DHCP Server, which has to be configured
accordingly and must be able to be reached via the network.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Function (continued)
• Support from the Access Control List (ACL); Commissioning and diagnostics
if this function is activated for one port, the switch forwards the
message frames received to this port if its source address is Setting options on the device itself:
present in the address table. All connected nodes can be • Redundancy manager RM;
2 automatically entered in the ACL.
• Syslog;
to establish a ring, a SCALANCE X-300 is switched to RM
mode. The Gigabit ports (electrical or optical) are preferably
Syslog compliant with RFC 3164 is used in the IP network for used as ring ports.
transmitting short, unencrypted text messages via UDP. This • Signal mask;
requires the use of a Syslog server that must be configured the signal mask is set to the current status of the
appropriately and must be accessible via the network. SCALANCE X-300 (setpoint) by pushbutton operation. The
• Time synchronization; signal mask defines which ports and which power supplies
diagnostic messages (log table entries, e-mails) are time- are to be monitored. The signaling contact only reports an
stamped. The local time is standardized throughout the error when a monitored port or a monitored feeder fails
network by means of synchronization with a SICLOCK time (deviation of setpoint/actual status).
transmitter, SNTP or NTP server or via IEEE1588, thereby • IP address;
simplifying the assignment of diagnostic messages of several the IP address is assigned via DHCP (Dynamic Host Configu-
devices. ration Protocol). If there is no corresponding server in the
• Fast replacement of devices in event of failure, by means of network, the IP address can be assigned using an enclosed
the C-PLUG switching medium software tool.
Diagnostic options on site:
Network topology and network configuration
• The following status information is displayed by LEDs on site:
The SCALANCE X-300 Industrial Ethernet switches with degree - Port status
of protection IP30 are typically accommodated in a control - Port mode (10/100/1 000 Mbit/s, full/half-duplex)
cabinet along with the nodes to be connected. Electrical and - Status of the two power supplies
optical versions can be installed together in star, line and ring - Signaling contact status
topologies. - Signal mask (setpoint status)
The following network structures and combinations of structures - RM mode
can be implemented: - Standby mode
• Fast Ethernet and Gigabit Ethernet rings with fast media • The status of the signaling contact is routed externally by
redundancy; means of floating relay contacts. This enables, for example,
to increase network availability, as many as 50 X-200, X-300, the module to be monitored via an input module from a
X-400 or X-500 switches can be cascaded in line can be controller.
connected into a ring • Monitoring via the Industrial Ethernet network;
• Several rings can be redundantly linked through the standby the following possibilities are available:
function - Remote via standard browser (Web-based management):
Selection of SCALANCE X-300 switches via the network from
• At the same time, SCALANCE X-300 supports redundant a PC with browser
connection of the ring structure to the corporate network with - Remote via SNMP V1, V2c, V3:
Rapid Spanning Tree. Secure integration of SCALANCE X-300 switches via the
• Star topology with SCALANCE X-300 switches: network into a network management system, e.g. SINEMA
The SCALANCE X-300 switch represents a star point which Server
can interconnect several nodes or subnets electrically or - Remote via PROFINET IO diagnostics:
optically. PROFINET diagnostic alarms from SCALANCE X-300
switches can be displayed using the relevant SIMATIC
When configuring the network, it is necessary to observe the engineering tools and they can also be processed in the
following boundary conditions: controller. The engineering outlay for the PLC and HMI have
• Maximum line length between two modules for multi-mode been drastically reduced due to the complete integration in
fiber-optic conductors: the SIMATIC concept for system error messages.
- 750 m at 1 Gbit/s
- 5 km at 100 Mbit/s
• Maximum line length between two modules for single-mode
fiber-optic conductors:
- 10 to 70 km at 1 Gbit/s
- 26 km at 100 Mbit/s
• Maximum cable length of the TP cable between two
SCALANCE X switches:
- Max. 100 m with IE FC cable 2x2 and IE FC RJ45 Plug 180
- Max. 100 m at 1 Gbit/s with IE FC standard cable 4x2 (90 m),
IE FC RJ45 modular outlet and patch cable (10 m)
- Max. 10 m using patches with TP cord
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
■ Function (continued)
Network management If faults occur in the network, the SCALANCE X-300 switch can
independently send error messages (traps) to a network man-
The network management provides the following functions: agement system or also e-mails to a predefined network admin-
• Password-protected dial-up for "Administrator" (read and write istrator.
authorization) and "User" (read only)
• Read-out of version and status information
Remote monitoring (RMON) provides the following functions:
The SCALANCE X-300 switch can collect statistics information
2
• Setting the signal and standby mask and address information according to the RMON groups 1 through 4. These include, for
• Fixed parameterization of the ports example, fault statistics that are kept for each port. This informa-
(data rates, half/full duplex) tion can be read out through web-based management in the sta-
tistics sub-area.
• Setting parameters of the VLANs and multicast services
• Parameterization of the standby connections for a redundant
ring link
• Setting of Rapid Spanning Tree parameters
• Parameterization of the web management services
• Security
- Ports can be connected or disconnected
- Authentication in accordance with IEEE 802.1x
- Support from Access Control List (ACL)
• Parameterization of user administration of SNMP V1, V2c, V3
• Output of statistics information
• Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
• Loading of new firmware versions or of the configuration data
via the network by a TFTP server or directly via HTTP/HTTPS
using a Web browser
• Saving the configuration data or log table via the network on a
TFTP server
■ Technical specifications
Article No. 6GK5304-2BD00-2AA3 6GK5306-1BF00-2AA3 6GK5307-3BL00-2AA3 6GK5307-3BM00-2AA3
Product-type designation SCALANCE X304-2FE SCALANCE X306-1LD FE SCALANCE X307-3 SCALANCE X307-3LD
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 10 Mbit/s
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Transfer rate 3 - - 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 6 7 10 10
connections for network components
or terminal equipment maximum
Number of electrical connections
• for network components 4 6 7 7
and terminal equipment
• for operator console - - - -
• for signaling contact 1 1 1 1
• for media module - - - -
• for power supply 1 1 1 1
• for redundant power supply 2 2 2 2
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port RJ45 port
and terminal equipment
• for operator console - - - -
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 2 1 - -
• at 1 000 Mbit/s - - 3 3
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 Product function
• Ring redundancy Yes Yes Yes Yes
• Redundancy manager Yes Yes Yes Yes
• Standby redundancy Yes Yes Yes Yes
• High Speed Redundancy Protocol Yes Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes Yes
• redundancy procedure STP Yes Yes Yes Yes
• RSTP redundancy protocol Yes Yes Yes Yes
• redundancy procedure MSTP Yes Yes Yes Yes
• Passive listening Yes Yes Yes Yes
Protocol is supported
• STP/RSTP Yes Yes Yes Yes
• STP Yes Yes Yes Yes
• RSTP Yes Yes Yes Yes
• RSTP big network support Yes Yes Yes Yes
• LACP Yes Yes Yes Yes
Product functions Security
Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• MSTP No No No No
• IEEE 1588 profile default No No No No
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX
0145X 0145X 0145X 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), CSA (Hazardous Location), CSA (Hazardous Location), CSA (Hazardous Location), CSA
C22.2 No. 213-M1987, Class C22.2 No. 213-M1987, Class C22.2 No. 213-M1987, Class C22.2 No. 213-M1987, Class
1 / Division 2 / Group A, B, C, 1 / Division 2 / Group A, B, C, 1 / Division 2 / Group A, B, C, 1 / Division 2 / Group A, B, C,
D / T4, Class 1 / Zone 2 / D / T4, Class 1 / Zone 2 / D / T4, Class 1 / Zone 2 / D / T4, Class 1 / Zone 2 /
Group IIC / T4 Group IIC / T4 Group IIC / T4 Group IIC / T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
Marine classification association
• American Bureau - - Yes Yes
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) - - Yes Yes
• Det Norske Veritas (DNV) - - Yes Yes
• Germanische Lloyd (GL) - - Yes Yes
• Lloyds Register of Shipping (LRS) - - Yes Yes
• Nippon Kaiji Kyokai (NK) - - Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 Ambient temperature
• during operating -10 … +60 °C -40 … +60 °C -40 … +60 °C -40 … +60 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP30 IP30 IP30 IP30
Design, dimensions and weight
Design compact compact compact compact
Width 120 mm 120 mm 120 mm 120 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 123 mm 123 mm 123 mm 123 mm
Net weight 1.4 kg 1.4 kg 1.4 kg 1.4 kg
Mounting type
• 19-inch installation No No No No
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
installation on a 35 mm installation on a 35 mm installation on a 35 mm installation on a 35 mm
standard mounting rail is standard mounting rail is standard mounting rail is standard mounting rail is
not permitted. not permitted. not permitted. not permitted.
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any Any Any Any
of star structuring (depending only on signal (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• SMTP server - - - -
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• for IRT PROFINET IO switch - - - -
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes Yes
• HTTP Yes Yes Yes Yes
• HTTPS Yes Yes Yes Yes
• TFTP Yes Yes Yes Yes
• FTP Yes Yes Yes Yes
• BOOTP Yes Yes Yes Yes
• SNMP v1 Yes Yes Yes Yes
• SNMP v2 Yes Yes Yes Yes
• SNMP v3 Yes Yes Yes Yes
• IGMP (snooping/querier) Yes Yes Yes Yes
• GMRP Yes Yes Yes Yes
• DCP Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes Yes
• I&M1 - higher level Yes Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX
0145X 0145X 0145X 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), (Hazardous Location), (Hazardous Location), (Hazardous Location),
CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987,
Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group
A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
Marine classification association
• American Bureau Yes Yes Yes Yes
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes Yes Yes
• Det Norske Veritas (DNV) Yes Yes Yes Yes
• Germanische Lloyd (GL) Yes Yes Yes Yes
• Lloyds Register of Shipping (LRS) Yes Yes Yes Yes
• Nippon Kaiji Kyokai (NK) Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 Ambient temperature
• during operating -40 … +60 °C -40 … +60 °C -40 … +60 °C -40 … +60 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP30 IP30 IP30 IP30
Design, dimensions and weight
Design Compact Compact Compact Compact
Width 120 mm 120 mm 180 mm 180 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 123 mm 123 mm 123 mm 123 mm
Net weight 1.4 kg 1.4 kg 1.65 kg 1.65 kg
Mounting type
• 19-inch installation No No No No
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
installation on a 35 mm installation on a 35 mm installation on a 35 mm installation on a 35 mm
standard mounting rail is standard mounting rail is standard mounting rail is standard mounting rail is
not permitted. not permitted. not permitted. not permitted.
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on Any (depending only on Any (depending only on Any (depending only on
of star structuring signal propagation time) signal propagation time) signal propagation time) signal propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• SMTP server - - - -
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes Yes
• HTTP Yes Yes Yes Yes
• HTTPS Yes Yes Yes Yes
• TFTP Yes Yes Yes Yes
• FTP Yes Yes Yes Yes
• BOOTP Yes Yes Yes Yes
• SNMP v1 Yes Yes Yes Yes
• SNMP v2 Yes Yes Yes Yes
• SNMP v3 Yes Yes Yes Yes
• IGMP (snooping/querier) Yes Yes Yes Yes
• GMRP Yes Yes Yes Yes
• DCP Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes Yes
• I&M1 - higher level Yes Yes Yes Yes
designation/location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX
0145X 0145X 0145X 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1 CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), (Hazardous Location), (Hazardous Location), (Hazardous Location),
CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987,
Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group Class 1 / Division 2 / Group
A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 / A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
Marine classification association
• American Bureau of Shipping Yes Yes - -
Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes - -
• Det Norske Veritas (DNV) Yes Yes - -
• Germanische Lloyd (GL) Yes Yes - -
• Lloyds Register of Shipping (LRS) Yes Yes - -
• Nippon Kaiji Kyokai (NK) Yes Yes - -
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2 Design
Width
compact
120 mm
compact
120 mm
Height 125 mm 125 mm
Depth 124 mm 124 mm
Net weight 1.4 kg 1.4 kg
Mounting type
• 19-inch installation No No
• 35 mm DIN rail mounting Yes Yes
• wall mounting Yes Yes
• S7-300 rail mounting Yes Yes
Mounting type When used in shipbuilding, installation on a When used in shipbuilding, installation on a
35 mm standard mounting rail is not permitted. 35 mm standard mounting rail is not permitted.
Product properties, functions,
components general
Cascading in the case of a 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on signal propagation time) Any (depending only on signal propagation time)
of star structuring
Product functions management,
configuration
Product function
• CLI Yes Yes
• web-based management Yes Yes
• MIB support Yes Yes
• TRAPs via email Yes Yes
• Configuration with STEP 7 Yes Yes
• RMON Yes Yes
• SMTP server - -
• Port mirroring Yes Yes
• CoS Yes Yes
• for IRT PROFINET IO switch - -
• PROFINET IO diagnosis Yes Yes
• switch-managed Yes Yes
Protocol is supported
• Telnet Yes Yes
• HTTP Yes Yes
• HTTPS Yes Yes
• TFTP Yes Yes
• FTP Yes Yes
• BOOTP Yes Yes
• SNMP v1 Yes Yes
• SNMP v2 Yes Yes
• SNMP v3 Yes Yes
• IGMP (snooping/querier) Yes Yes
• GMRP Yes Yes
• DCP Yes Yes
• LLDP Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes
• I&M1 -higher level Yes Yes
designation/location designation
Product functions Diagnosis
Product function
• Port diagnostics Yes Yes
• Statistics packet size Yes Yes
• Statistics packet type Yes Yes
• Error statistics Yes Yes
• SysLog Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
2
optical Industrial Ethernet networks; RJ45 ports, electrical
integrated redundancy manager, • SCALANCE X304-2FE; 6GK5304-2BD00-2AA3
IT functions (RSTP, VLAN, etc.), 2 x 100 Mbit/s
network management via SNMP SC port, optical (multimode,
and web server; glass), up to 5 km
incl. operating instructions, 4 x 10/100 Mbit/s
Industrial Ethernet network manual RJ45 ports, electrical
and configuration software • SCALANCE X306-1LD FE; 6GK5306-1BF00-2AA3
on CD-ROM; C-PLUG included in 1 x 100 Mbps
the scope of delivery SC port, optical
• SCALANCE X310; 6GK5310-0FA00-2AA3 (single-mode, glass), up to 5 km
3 x 10/100/1 000 Mbit/s 6 x 10/100 Mbps
RJ45 ports, electrical RJ45 ports, electrical
7 x 10/100 Mbit/s • SCALANCE X320-1FE; 6GK5320-1BD00-2AA3
RJ45 ports, electrical 1 x 100 Mbps
• SCALANCE X308-2; 6GK5308-2FL00-2AA3 SC port, optical
2 x 1 000 Mbit/s (multi-mode, glass), up to 5 km
SC ports, optical 20 x 10/100 Mbps
(multimode, glass), up to 750 m RJ45 ports, electrical
1 x 10/100/1 000 Mbit/s • SCALANCE X320-3LD FE; 6GK5320-3BF00-2AA3
RJ45 port, electrical 1 x 100 Mbps
7 x 10/100 Mbit/s SC port, optical
RJ45 ports, electrical; (multi-mode, glass), up to 5 km
• SCALANCE X308-2LD; 6GK5308-2FM00-2AA3 2 x 100 Mbps
2 x 1 000 Mbit/s SC port, optical
SC ports, optical (single-mode, glass), up to 26 km
(single-mode, glass), up to 10 km 20 x 10/100 Mbps
1 x 10/100/1 000 Mbit/s RJ45 ports, electrical
RJ45 port, electrical, Full Gigabit Ethernet switches
7 x 10/100 Mbit/s
RJ45 ports, electrical; • SCALANCE X308-2M; 6GK5308-2GG00-2AA2
4 x 10/100/1 000 Mbps RJ45
• SCALANCE X308-2LH; 6GK5308-2FN00-2AA3 ports, electrical
2 x 1 000 Mbit/s 2 x 10/100/1 000 Mbps slots for 2-
SC ports, optical port media modules, electrical or
(single-mode, glass), up to 40 km optical
1 x 10/100/1 000 Mbit/s
RJ45 port, electrical, • SCALANCE X308-2M TS; 6GK5308-2GG00-2CA2
7 x 10/100 Mbit/s 4 x 10/100/1 000 Mbps RJ45
RJ45 ports, electrical ports, electrical
2 x 10/100/1 000 Mbps slots for 2-
• SCALANCE X308-2LH+; 6GK5308-2FP00-2AA3 port media modules, electrical or
2 x 1 000 Mbit/s optical,
SC ports, optical with extended temperature range
(single-mode, glass), up to 70 km and EN 50155 approval for railway
1 x 10/100/1 000 Mbit/s applications
RJ45 port, electrical,
7 x 10/100 Mbit/s Media modules See "Media modules for modular
RJ45 ports, electrical SCALANCE X-300 managed"
• SCALANCE X307-3; 6GK5307-3BL00-2AA3 Accessories
3 x 1 000 Mbit/s
SC ports, optical IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
(multi-mode, glass), up to 750 m (Type A)
7 x 10/100 Mbit/s
RJ45 ports, electrical 4-core, shielded TP installation
cable for connection to
• SCALANCE X307-3LD; 6GK5307-3BM00-2AA3 IE FC RJ45 outlet / IE FC RJ45 plug;
3 x 1 000 Mbit/s PROFINET-compliant;
SC ports, optical with UL approval;
(single-mode, glass), up to 10 km sold by the meter;
7 x 10/100 Mbit/s max. quantity 1 000 m,
RJ45 ports, electrical minimum order 20 m
IE FC TP Standard Cable GP 4 x 2 6XV1870-2E
8-core, shielded TP installation
cable for connection to
IE FC RJ45 Modular Outlet
for universal application;
with UL approval;
sold by the meter;
max quantity 1 000 m,
minimum order 20 m
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with two RJ45 connectors
• 0.5 m 6XV1870-3QE50
•1m 6XV1870-3QH10
•2m 6XV1870-3QH20
•6m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
1)
Special fiber-optic cables, lengths and accessories available on request
2)
Special tools and trained personnel are required for pre-assembling
glass fiber-optic cables
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Design (continued)
PC PC
SCALANCE
XM416-4C
SCALANCE
XM416-4C 2
S7-400
G_IK10_XX_10215
ET 200SP ET 200SP ET 200SP
PC
■ Design
The SCALANCE XR-300 Industrial Ethernet switches with The SCALANCE XR-300 switches are available with the following
rugged metal enclosure with IP30 degree of protection are port types:
optimized for installation in the 19" control cabinet. Versions are • 12 slots for electrical or optical 2-port media modules for multi-
available with 24 V DC or 230 V AC connection. The connection mode or single-mode connections; the optical media modules
of the power supply and the data cable outlet are located option- are available in various connection technologies
ally either at the front or rear of the device.
• The RJ45 sockets are designed to be industry-compatible
The switches have: with additional sleeves, for connection of the Industrial
• 4-pin terminal block for redundant voltage feed for protection Ethernet FC RJ45 Plug 180
against voltage failure in 24 V DC version • All electrical Ethernet interfaces support 10/100/1 000 Mbit/s,
• 3-pin terminal block for voltage feed in 230 V AC version all optical Ethernet interfaces support 100 or 1 000 Mbit/s
• 2-pin terminal block for connecting the isolated signaling • The SCALANCE XR-300 switches support Gigabit Ethernet (1
contact for simple display of faults 000 Mbit/s) at all ports. The 24 ports are divided into three
groups of eight ports each (Gigabit Ethernet Blocking).
• Row of LEDs for indicating status information (power, link Gigabit Ethernet is supported with full wire speed within each
status, data transfer, power supply, signaling contact) group, but not between the groups.
• SELECT/SET pushbutton for easy setting of the fault signaling
contact on the device
• Slot for optional C-PLUG swap medium on the side of the
device for easy replacement in the event of a fault
• Console port (serial interface) for on-site parameterization/
diagnostics (RJ11 cable to RS232 (9-pin) included in scope of
delivery)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Design (continued)
Product versions SCALANCE XR324-12M TS (12 media module slots)
SCALANCE XR324-12M (12 media module slots) A variant is available with
Versions are available with • LEDs, power supply connection and data cable outlet on the
2 • LEDs, power supply connection and data cable outlet on the
front
front
The SCALANCE XR324-12M TS has twelve media module slots
• LEDs on the front, power supply connection and data cable and
outlet at the rear • 1 x 24 V DC power supply unit
All versions have twelve media module slots and
• 1 x 24 V DC power supply unit
• 1 x 230 V AC power supply
Front
Rear
Slot for
C-PLUG
G_IK10_XX_10283
Connection example: Connection example:
IE FC RJ45 Plug FastConnect connector FC BFOC Plug FastConnect connector
to MM992-2CUC media module to MM991-2 media module
(with retaining collar) (multimode)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Function
• Integrated redundancy manager for constructing Fast Network topology and network configuration
Ethernet and Gigabit Ethernet ring topologies with high-speed
media redundancy. Reliable communication is achieved by The network topology can easily be adapted to the structure of
closing an optical or electrical line with SCALANCE X-400, the plant using SCALANCE XR-300 Industrial Ethernet switches.
X-300 or X-200 switches to form a ring. The redundancy
manager (RM) integrated in the SCALANCE XR-300 switch
The following network structures and combinations of structures
can be implemented:
2
monitors the function of the network. It recognizes the failure • Fast Ethernet with fast media redundancy;
of a transmission link or of SCALANCE X switch in the ring to increase network availability, as many as 50 X-200, X-300,
and activates the substitute path within a maximum of X-400 or X-500 switches cascaded in line can be connected
0.2 seconds. into a ring.
• Redundant interfacing to company networks; • Several rings can be redundantly linked through the standby
SCALANCE XR-300 switches support the standardized function
redundancy procedures Spanning Tree Protocol (STP) and
Rapid Spanning Tree Protocol (RSTP). This enables a • In addition, SCALANCE XR-300 supports redundant
subnetwork to be connected redundantly to a higher level connection of the ring structure to the corporate network with
corporate network with reduced requirements for the reconfig- a rapid spanning tree.
uration time (in the order of seconds). By supporting the • Star topology with SCALANCE XR-300 switches:
Multiple Spanning Tree Protocol (MSTP), a network can also Each SCALANCE XR-300 switch represents a neutral point
be split into multiple sub-segments. that can connect up to 24 nodes or subnets with each other
• Support of virtual networks (VLAN); electrically.
for structuring Industrial Ethernet networks with a fast growing When configuring the network, it is necessary to observe the
number of users, a physically existing network can be divided following boundary conditions:
into several virtual networks.
• Maximum line length between two modules for multi-mode
• Load limiting when multicast protocols (e.g. video trans- fiber-optic conductors:
mission) are used; - 5 km at 100 Mbit/s
through learning the multicast sources and targets (IGMP - 750 m at 1 Gbit/s
Snooping, IGMP Querier), SCALANCE XR-300 switches can
also filter multicast data traffic and therefore limit the load in • Maximum line length between two modules for single-mode
the network. Multicast and broadcast traffic can be limited. fiber-optic conductors:
- 26 km to 70 km at 100 Mbps
• Time synchronization; - 10 to 120 km at 1 Gbit/s
diagnostic messages (log table entries, e-mails) are time-
stamped. The local time is standardized throughout the • Maximum cable length of the TP cable between two
network by means of synchronization with a SICLOCK time SCALANCE X switches:
transmitter, SNTP or NTP server or via IEEE1588, thereby - Max. 100 m with IE FC cable 2x2 and IE FC RJ45 Plug 180
simplifying the assignment of diagnostic messages of several - Max. 100 m at 1 Gbit/s with IE FC Standard Cable 4x2
devices. (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
- Max. 10 m using patches with TP cord
• Fast replacement of devices in event of failure, by means of
the C-PLUG switching medium
• Link aggregation (IEEE 802.1q) for bundling data streams
• Quality of Service (IEEE 802.1p) for prioritization of network
traffic
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Function (continued)
Commissioning and diagnostics Network management
Setting options on the device itself: The network management provides the following functions:
• Redundancy manager RM; • Password-protected dial-up for "Administrator" (read and write
2 to establish a ring, a SCALANCE XR-300 is switched to RM
mode. The Gigabit ports (electrical or optical) are preferably
authorization) and "User" (read only)
• Read-out of version and status information
used as ring ports. The non-ring ports of the RM can be used
freely for the connection of data terminals and networks. • Setting the signal and standby mask and address information
If the redundancy procedure MRP standardized by PROFINET • Fixed parameterization of the ports (data rates, half/full
is used, the RM is adjusted automatically. duplex)
• Signal mask; • Setting of Spanning/Rapid Spanning Tree parameters
the signal mask is set to the current status of the • Parameterization of the web management services
SCALANCE XR-300 (setpoint) by pushbutton operation.
The signal mask defines which ports and which power • Security
supplies are to be monitored. The signaling contact only - Ports can be connected or disconnected
reports an error when a monitored port or a monitored feeder - Port-based network access control according to
fails (deviation of setpoint/actual status). IEEE 802.1x
- Authentication in accordance with IEEE 802.1x
• IP address; (available soon)
the IP address is assigned via DHCP (Dynamic Host Configu- - Support of Access Control List (ACL) (available soon)
ration Protocol). If there is no corresponding server in the
network, the IP address can be assigned using an enclosed • Output of statistics information
software tool. • Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
Diagnostic options on site:
• Loading of new firmware versions or of the configuration data
• The following status information is displayed by LEDs on site: via the network by a TFTP server or directly via HTTP/HTTPS
- Port status using a Web browser
- Port mode (10/100/1 000 Mbit/s, full/half-duplex)
- Status of the two power supplies • Saving the configuration data or log table via the network on a
- Signaling contact status TFTP server
- Signal mask (setpoint status) If faults occur in the network, the SCALANCE XR-300 switch
- RM mode can independently send error messages (traps) to a network
- Standby mode management system or also e-mails to a predefined network
• The status of the signaling contact is routed externally by administrator.
means of floating relay contacts. This enables, for example,
the module to be monitored via an input module from a Remote monitoring (RMON) provides the following functions:
controller. The SCALANCE XR-300 switch can collect statistics information
according to the RMON groups 1 through 4. These include,
• Monitoring via the Industrial Ethernet network; for example, fault statistics that are kept for each port. This infor-
the following possibilities are available: mation can be read out through web-based management in the
- Remote via standard browser (Web-based management): statistics sub-area.
Selection of SCALANCE XR-300 switches via the network
from a PC with browser
- Remote via SNMP V1, V2c, V3:
Secure integration of SCALANCE XR-300 switches via the
network into a network management system, e.g. SINEMA
Server
- Remote via PROFINET IO diagnostics:
PROFINET diagnostic alarms from SCALANCE X-300
switches can be displayed using the relevant SIMATIC
engineering tools and they can also be processed in the
controller. The engineering outlay for the PLC and HMI have
been drastically reduced due to the complete integration in
the SIMATIC concept for system error messages.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
■ Technical specifications
Article No. 6GK5324-0GG00-1AR2 6GK5324-0GG00-1HR2 6GK5324-0GG00-1CR2
Product-type designation SCALANCE XR324-12M SCALANCE XR324-12M SCALANCE XR324-12M TS
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 24 24 24
connections for network components
or terminal equipment maximum
Number of electrical connections
• for operator console 1 1 1
• for signaling contact 1 1 1
• for media module 12 12 12
• for power supply 1 1 1
• for redundant power supply 1 1 1
Design of electrical connection
• for network components Dependent on selected media Dependent on selected media Dependent on selected media
and terminal equipment modules modules modules
• for operator console RJ11 port RJ11 port RJ11 port
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s Dependent on selected media Dependent on selected media Dependent on selected media
modules modules modules
• at 1 000 Mbit/s Dependent on selected media Dependent on selected media Dependent on selected media
modules modules modules
design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage redundant No No No
power supply unit
Type of supply voltage DC DC DC
Supply voltage external 24 V 24 V 24 V
• minimum 19.2 V 19.2 V 19.2 V
• maximum 28.8 V 28.8 V 28.8 V
Product component fusing Yes Yes Yes
at power supply input
Type of fusing at input F 5 A / 125 V F 5 A / 125 V F 5 A / 125 V
for supply voltage
Consumed current maximum 1.8 A 1.8 A 1.8 A
Active power loss
• at 24 V for DC 44 W 44 W 44 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C
• Comment Reduced operating temperature Reduced operating temperature Reduced operating temperature
through the use of media modules through the use of media modules through the use of media modules
(-40 °C to +70 °C) or (-40 °C to +70 °C) or (-40 °C to +70 °C) or
SFP plug-in transceivers SFP plug-in transceivers SFP plug-in transceivers
(-40 °C to +60 °C). (-40 °C to +60 °C). (-40 °C to +60 °C).
If the device is installed in the vertical If the device is installed in the vertical If the device is installed in the vertical
position, the maximum operating position, the maximum operating position, the maximum operating
temperature is reduced to +50 °C. temperature is reduced to +50 °C. temperature is reduced to +50 °C.
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) Conformal coating, no Conformal coating, no Conformal coating, yes
operation mode
Protection class IP IP20 IP20 IP20
Design, dimensions and weight
Design 19" rack 19" rack 19" rack
Width 483 mm 483 mm 483 mm
Height 44 mm 44 mm 44 mm
Depth 305 mm 305 mm 305 mm
Net weight 5.5 kg 5.5 kg 5.5 kg
Mounting type
• 19-inch installation Yes Yes Yes
• 35 mm DIN rail mounting No No No
• wall mounting No No No
• S7-300 rail mounting No No No
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
the device must be secured the device must be secured the device must be secured
in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points
Product properties, functions,
components general
Cascading in the case of a 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on signal Any (depending only on signal Any (depending only on signal
of star structuring propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes
• RMON Yes Yes Yes
• SMTP server - - -
• Port mirroring Yes Yes Yes
• CoS Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes
• switch-managed Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes
• Broadcast blocking Yes Yes Yes
Protocol is supported SSH Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes
Protocol is supported
• NTP No No No
• SNTP Yes Yes Yes
• MSTP Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Class 1, Zone 2, Group A, B, C, D / T4, Class 1, Zone 2, Group A, B, C, D / T4, Class 1, Zone 2,
Group IIC, T4 Group IIC, T4 Group IIC, T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4 EN 60079-15: 2005, II 3 G Ex nA II T4 EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X KEMA 07 ATEX 0145X KEMA 07 ATEX 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), (Hazardous Location), (Hazardous Location),
CSA C22.2 No. 213-M1987, Class 1 / CSA C22.2 No. 213-M1987, Class 1 / CSA C22.2 No. 213-M1987, Class 1 /
Division 2 / Group A, B, C, D / T4, Division 2 / Group A, B, C, D / T4, Division 2 / Group A, B, C, D / T4,
Class 1 / Zone 2 / Group IIC / T4 Class 1 / Zone 2 / Group IIC / T4 Class 1 / Zone 2 / Group IIC / T4
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval Yes Yes Yes
• Railway application in accordance No No Yes
with EN 50155
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C
• Comment Reduced operating temperature through the use of Reduced operating temperature through the use of
media modules (-40 °C to +70 °C) or media modules (-40 °C to +70 °C) or
SFP plug-in transceivers (-40 °C to +60 °C). SFP plug-in transceivers (-40 °C to +60 °C).
If the device is installed in the vertical position, If the device is installed in the vertical position,
the maximum operating temperature is reduced to +50 °C. the maximum operating temperature is reduced to +50 °C.
Relative humidity at 25 °C without 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) Conformal coating, no Conformal coating, no
operation mode
Protection class IP IP20 IP20
Design, dimensions and weight
Design 19" rack 19" rack
Width 483 mm 483 mm
Height 44 mm 44 mm
Depth 305 mm 305 mm
Net weight 5.9 kg 5.9 kg
Mounting type
• 19-inch installation Yes Yes
• 35 mm DIN rail mounting No No
• wall mounting No No
• S7-300 rail mounting No No
Mounting type When used in shipbuilding, the device must be secured When used in shipbuilding, the device must be secured
in the 19" rack at four points in the 19" rack at four points
Product properties, functions,
components general
Cascading in the case of a redundant 50 50
ring at reconfiguration time
of < 0.3 s
Cascading in cases of star structuring Any (depending only on signal propagation time) Any (depending only on signal propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes
• web-based management Yes Yes
• MIB support Yes Yes
• TRAPs via email Yes Yes
• Configuration with STEP 7 Yes Yes
• RMON Yes Yes
• SMTP server - -
• Port mirroring Yes Yes
• CoS Yes Yes
• for IRT PROFINET IO switch - -
• PROFINET IO diagnosis Yes Yes
• switch-managed Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
2 Product function
• ACL - port/MAC-based Yes Yes
• IEEE 802.1x (radius) Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes
• broadcast blocking Yes Yes
Protocol is supported SSH Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes
Protocol is supported
• NTP No No
• SNTP Yes Yes
• MSTP Yes Yes
• IEEE 1588 profile default Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM No No
• for hazardous zone No No
• for safety of CSA and UL UL 508, CSA C22.2 No. 142-M1987 UL 508, CSA C22.2 No. 142-M1987
• for hazardous area of CSA and UL No No
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61000-6-2:2005, EN 61000-6-4:2007
• CE mark Yes Yes
• C-Tick Yes Yes
• KC approval Yes Yes
• Railway application in accordance No No
with EN 50155
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ Application
SCALANCE X-300 products enable the establishment of IP cameras and IP telephones, with energy over the data cable.
switched networks both at the field level and at the control level The switch is designed with IP20 degree of protection for instal-
where high data transfer rates are required in addition to high lation in control cabinets.
network availability and extensive diagnostics facilities.
The SCALANCE X308-2M PoE switch supplies PoE-compatible
devices, such as IWLAN access points SCALANCE W,
The main area of application is found in high-performance plant
networks with interfaces to the corporate network. 2
Office
HiPath IP
Access Phone
Point
PoE PoE
SCALANCE
X308-2M PoE SCALANCE
XR324-4M PoE
SIMATIC SCALANCE
MV420 W788 SCALANCE
W786
SCALANCE
SIMATIC PoE PoE X108PoE
MV440 PoE
PoE IP Camera
IP Fixdome PoE
SIMATIC
PoE Camera
G_IK10_XX_10286
MV440
■ Design
The SCALANCE X-300 Industrial Ethernet switches with their The switches have:
robust metal enclosure are optimized for mounting on a standard • 4-pin terminal block for connection of the redundant power
DIN rail and the S7-300 mounting rail. Direct wall mounting in supply (2 x 24 V DC)
different positions is also possible. Due to the S7-300 enclosure
dimensions, the devices are ideally suited for integration in an • Row of LEDs for indicating status information (power, link
automation system using S7-300 components. status, data transfer, error indication, redundancy manager,
standby manager)
• 2-pin terminal block for connecting the isolated signaling
contact
• SELECT/SET pushbutton for on-site configuration of the
signaling contact
• Slot for optional C-PLUG swap medium on the rear of the
device for the easy replacement of the device in the event of
a fault
• SCALANCE X308-2M PoE has four integrated electrical,
PoE-compatible Ethernet ports and two slots for accommo-
dating 2-port media modules
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ Function
• Support of Power over Ethernet (PoE) according to • Support of the DHCP Option 82, 66, 67 (Dynamic Host
IEEE 802.3at Type 1 (corresponds to IEEE 802.3af) Configuration Protocol);
• Increase of the network performance; this facilitates the IP address assignment of a terminal
by filtering the data traffic on the basis of the Ethernet (MAC) depending on the connected switch port. The IP address is
2 address of the data terminals, data traffic remains local;
only data intended for users of another subnetwork is
assigned via a DHCP Server, which has to be configured
accordingly and must be able to be reached via the network.
forwarded by the switch. • Support of Access Control List (ACL);
• Simple network configuration and network expansion; if this function is activated for a port, the switch only forwards
the switch saves the data received at the ports and forwards message frames received at this port if their source address
it automatically to the destination address. The limitation of the is listed in the address table. All connected nodes can be
network expansion by collision detection (CSMA/CD automatically entered in the ACL.
procedure) terminates at the port. • Syslog;
• Limitation of the error propagation to the affected subnetwork; Syslog compliant with RFC 3164 is used in the IP network for
the SCALANCE X-300 switches only forward data with a valid transmitting short, unencrypted text messages via UDP. This
checksum (CRC). requires the use of a Syslog server that must be configured
appropriately and must be accessible via the network.
• Integration of existing subnetworks with 10 Mbit/s into Fast
Ethernet networks with 100 Mbit/s; • Time synchronization;
at the twisted-pair ports, the SCALANCE X-300 switches diagnostic messages (log table entries, e-mails) are time-
automatically recognize the conductor pairs for transmission stamped. The local time is standardized throughout the
and reception (autocrossover), the data transfer rate of 10 or network by means of synchronization with a SICLOCK time
100 or 1 000 Mbit/s, as well as full-duplex and half-duplex transmitter, SNTP or NTP server or via IEEE1588, thereby
mode (autonegotiation). simplifying the assignment of diagnostic messages of several
devices.
• High-performance connection of SCALANCE X-300 switches
with 1 Gbit/s; Network topology and network configuration
SCALANCE X-300 PoE switches have up to eight Gigabit
Ethernet ports for connecting the switches to each other or The SCALANCE X-300 Industrial Ethernet switches are typically
with other Gigabit-Ethernet-enabled components (e.g. accommodated together with the nodes to be connected in one
SCALANCE X-400, X-500) control cabinet. Electrical and optical versions can be installed
together in star, line and ring topologies.
• Integrated redundancy manager for constructing Fast
Ethernet and Gigabit Ethernet ring topologies with high-speed The following network structures and combinations of structures
media redundancy. can be implemented:
• High-speed standby redundancy; • Fast Ethernet and Gigabit Ethernet rings with fast media
several network segments such as rings can be intercon- redundancy;
nected redundantly with SCALANCE X-300 by means of the to increase network availability, as many as 50 X-200, X-300,
integrated standby function. Two X-300 switches are X-400 or X-500 switches can be cascaded in line can be
configured in a ring as a master and slave and are connected connected into a ring.
via two links to the other ring. The redundant link can be • Several rings can be redundantly linked through the standby
implemented at 1 000 Mbit/s. function.
• Redundant interfacing to higher-level networks; • At the same time, SCALANCE X-300 supports redundant
SCALANCE X-300 switches support the standardized connection of the ring structure to the corporate network with
redundancy procedures Spanning Tree Protocol (STP) and Rapid Spanning Tree.
Rapid Spanning Tree Protocol (RSTP). This enables a • Star topology with SCALANCE X300PoE switches:
subnetwork to be connected redundantly to a higher-level The SCALANCE X-308-2M PoE switch represents a neutral
network with reduced requirements for the reconfiguration point that can connect up to eight nodes or subnets with each
time (in the order of seconds). By supporting the Multiple other electrically or optically.
Spanning Tree Protocol (MSTP), a network can also be split
into multiple sub-segments. When configuring the network, it is necessary to observe the
• Support of virtual networks (VLAN); following boundary conditions:
for structuring Industrial Ethernet networks with a fast growing • Maximum line length between two modules for multi-mode
number of users, a physically existing network can be divided fiber-optic conductors:
into several virtual networks. - 750 m at 1 Gbit/s
• Load limiting when multicast protocols (e.g. video trans- - 5 km at 100 Mbit/s
mission) are used; • Maximum line length between two modules for single-mode
through learning the multicast sources and targets (IGMP fiber-optic conductors:
Snooping, IGMP Querier), SCALANCE X-300 switches can - 10 to 120 km at 1 Gbit/s
also filter multicast data traffic and therefore limit the load in - 26 to 70 km at 100 Mbps
the network. • Maximum cable length of the TP cable between two
• Configuration of the ports for terminals that support authenti- SCALANCE X switches:
cation in accordance with IEEE 802.1x. - Max. 100 m at 10/100 Mbit/s with IE FC Cable 2x2 and
Authentication is by means of a RADIUS server that must be IE FC RJ45 Plug 180
configured appropriately and must be accessible via the - Max. 100 m at 1 Gbit/s with IE FC Standard Cable 4x2
network. (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
- Max. 10 m using patches with TP cord
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ Function (continued)
Commissioning and diagnostics Network management
Setting options on the device itself: The network management provides the following functions:
• Redundancy manager RM; • Password-protected dial-up for "Administrator" (read and write
to establish a ring, a SCALANCE X-300 is switched to RM
mode. The Gigabit ports (electrical or optical) are preferably
authorization) and "User" (read only)
• Read-out of version and status information
2
used as ring ports.
• Setting the signal and standby mask and address information
• Signal mask;
the signal mask is set to the current status of the • Fixed parameterization of the ports (data rates, half/full
SCALANCE X-300 (setpoint) by pushbutton operation. The duplex)
signal mask defines which ports and which power supplies • Setting parameters of the VLANs and multicast services
are to be monitored. The signaling contact only reports • Parameterization of the standby connections for a redundant
an error when a monitored port or a monitored feeder fails ring link
(deviation of setpoint/actual status).
• Setting of Rapid Spanning Tree parameters
• IP address;
the IP address is assigned via DHCP (Dynamic Host Configu- • Parameterization of the web management services
ration Protocol). If there is no corresponding server in the • Security
network, the IP address can be assigned using an enclosed - Ports can be connected or disconnected
software tool. - Authentication in accordance with IEEE 802.1x
- Support of Access Control List (ACL)
Diagnostic options on site:
• Parameterization of user administration of SNMP V1, V2c, V3:
• The following status information is displayed by LEDs on site:
- Port status • Output of statistics information
- Port mode (10/100/1 000 Mbit/s, full/half-duplex) • Diagnosis of data traffic by means of a parameterizable mirror
- Status of the two power supplies port with a standard commercial network analyzer
- Signaling contact status • Loading of new firmware versions or of the configuration data
- Signal mask (setpoint status) via the network by a TFTP server or directly via HTTP/HTTPS
- RM mode using a Web browser
- Standby mode
• Saving the configuration data or log table via the network on a
• The status of the signaling contact is routed externally by TFTP server
means of floating relay contacts. This enables, for example,
the module to be monitored via an input module from a If faults occur in the network, the SCALANCE X-300 switch
controller. can independently send error messages (traps) to a network
• Monitoring via the Industrial Ethernet network; management system or also e-mails to a predefined network
the following possibilities are available: administrator.
- Remote via standard browser (Web-based management): Remote monitoring (RMON) provides the following functions:
Selection of SCALANCE X-300 switches via the network from The SCALANCE X-300 switches can collect statistics informa-
a PC with browser tion according to the RMON groups 1 through 4. These include,
- Remote via SNMP V1, V2c, V3: for example, fault statistics that are kept for each port. This infor-
Secure integration of SCALANCE X-300 switches via the mation can be read out through web-based management in the
network into a network management system, e.g. SINEMA statistics sub-area.
Server
- Remote via PROFINET IO diagnostics:
PROFINET diagnostic alarms from SCALANCE X-300
switches can be displayed using the relevant SIMATIC
engineering tools and they can also be processed in the
controller. The engineering outlay for the PLC and HMI have
been drastically reduced due to the complete integration in
the SIMATIC concept for system error messages.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ Technical specifications
Article No. 6GK5308-2QG00-2AA2 Article No. 6GK5308-2QG00-2AA2
Product-type designation SCALANCE X308-2M POE Product-type designation SCALANCE X308-2M POE
Transmission rate Permitted ambient conditions
2 Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
Ambient temperature
• during operating -40 … +60 °C
Transfer rate 3 1 000 Mbit/s • during storage -40 … +70 °C
Interfaces • during transport -40 … +70 °C
Number of electrical/optical connec- 8 • Comment If the device is installed in the vertical
tions for network components or ter- position, the maximum operating tem-
minal equipment maximum perature is reduced to 60 °C.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300PoE managed
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
2
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Application (continued)
Office
2
HiPath IP
Access Phone
Point
PoE PoE
SCALANCE
X308-2M PoE SCALANCE
XR324-4M PoE
SIMATIC SCALANCE
MV420 W788 SCALANCE
W786
SCALANCE
SIMATIC PoE PoE X108PoE
MV440 PoE
PoE IP Camera
IP Fixdome PoE
SIMATIC
PoE Camera
G_IK10_XX_10286
MV440
■ Design
The SCALANCE XR-300PoE Industrial Ethernet switches with The SCALANCE XR-300PoE switches are available with the
rugged metal enclosure with IP20 degree of protection are following types of port:
optimized for installation in the 19" control cabinet. Versions are • 16 integrated RJ45 ports, eight RJ45 ports supporting PoE;
available with either 24 V DC or 100 - 240 V AC connections.
The connection of the power supply and the data cable outlet • The RJ45 sockets are designed to industry standards with
are located optionally either at the front or rear of the device. additional retaining collars for the connection of the Industrial
Ethernet FC RJ45 Plug 180
The switches have: • All electrical Ethernet interfaces support 10/100/1 000 Mbit/s,
• 4-pin terminal block for redundant voltage feed to protected all optical Ethernet interfaces support 100 or 1 000 Mbit/s
against power failure at 24 V DC • The SCALANCE XR-300 switches support Gigabit Ethernet
• 2-pin terminal block for voltage feed at 100 - 240 V AC (1 000 Mbit/s) at all ports. The 24 ports are divided into three
• 2-pin terminal block for connecting the isolated signaling groups of eight ports each (Gigabit Ethernet Blocking).
contact for simple display of faults Gigabit Ethernet is supported with full wire speed within each
group, but not between the groups.
• Row of LEDs for indicating status information (power, link
status, data transfer, power supply, signal contact)
• SELECT/SET pushbutton for easy setting of the fault signal
contact on the device
• Slot for optional C-PLUG swap medium on the side of the
device for easy replacement of the device in the event of a
fault
• Console port (serial interface) for on-site parameterization/
diagnostics (RJ11 cable to RS232 (9-pin) included in scope of
delivery)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Design (continued)
Product versions SCALANCE XR324-4M PoE TS(4 media module slots)
SCALANCE XR324-4M PoE (4 media module slots) A version is available with
Versions are available with • LEDs, power supply connection and data cable outlet on the
2 • LEDs, power supply connection and data cable outlet at the
front
front;
All versions have four media module slots and
• LEDs at the front, power supply connection and data cable • 1 x 24 V DC power supply unit
outlet at the rear
All versions have twelve media module slots and
• 1 x 24 V DC power supply unit
• 1 x 100 - 240 V AC power supply unit
Front
Rear
Slot for
C-PLUG
G_IK10_XX_10283
Connection example: Connection example:
IE FC RJ45 Plug FastConnect connector FC BFOC Plug FastConnect connector
to MM992-2CUC media module to MM991-2 media module
(with retaining collar) (multimode)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Function
• Support of Power over Ethernet (PoE) to IEEE 802.3at Type1 Network topology and network configuration
(corresponds to IEEE 802.3af)
The network topology can easily be adapted to the structure of
• Integrated redundancy manager for constructing Fast the plant using SCALANCE XR-300 Industrial Ethernet switches.
Ethernet and Gigabit Ethernet ring topologies with high-speed
media redundancy. Reliable communication is achieved by
closing an optical or electrical line with SCALANCE X-400,
The following network structures and combinations of structures
can be implemented:
2
X-300 or X-200 switches to form a ring. The redundancy • Fast Ethernet with fast media redundancy;
manager (RM) integrated in the SCALANCE XR-300 switch to increase network availability, as many as 50 X-200, X-300,
monitors the function of the network. It recognizes the failure X-400 or X-500 switches cascaded in line can be connected
of a transmission link or of SCALANCE X switch in the ring and into a ring.
activates the substitute path within a maximum of • Several rings can be redundantly linked through the standby
0.2 seconds. function
• Redundant interfacing to company networks; • In addition, SCALANCE XR-300 supports redundant
SCALANCE XR-300 switches support the standardized connection of the ring structure to the corporate network with
redundancy procedures Spanning Tree Protocol (STP) and a rapid spanning tree.
Rapid Spanning Tree Protocol (RSTP). This enables a
subnetwork to be connected redundantly to a higher level • Star topology with SCALANCE XR-300 switches:
corporate network with reduced requirements for the reconfig- Each SCALANCE XR-300 switch represents a neutral point
uration time (in the order of seconds). By supporting the that can connect up to 24 nodes or subnets with each other
Multiple Spanning Tree Protocol (MSTP), a network can also electrically.
be split into multiple sub-segments. When configuring the network, it is necessary to observe the
• Support of virtual networks (VLAN); following boundary conditions:
for structuring Industrial Ethernet networks with a fast growing • Maximum line length between two modules for multi-mode
number of users, a physically existing network can be divided fiber-optic conductors:
into several virtual networks. - 5 km at 100 Mbit/s
• Load limiting when multicast protocols (e.g. video trans- - 750 m at 1 Gbit/s
mission) are used; • Maximum line length between two modules for single-mode
through learning the multicast sources and targets (IGMP fiber-optic conductors:
Snooping, IGMP Querier), SCALANCE XR-300 switches can - 26 to 70 km at 100 Mbps
also filter multicast data traffic and therefore limit the load in - 10 to 120 km at 1 Gbit/s
the network. Multicast and broadcast traffic can be limited.
• Maximum cable length of the TP cable between two
• Time synchronization; SCALANCE X switches:
diagnostic messages (log table entries, e-mails) are time- - Max. 100 m at 10/100 Mbit/s with IE FC Cable 2x2 and
stamped. The local time is standardized throughout the IE FC RJ45 Plug 180
network by means of synchronization with a SICLOCK, or - Max. 100 m at 1 Gbit/s with IE FC Standard Cable 4x2
SNTP / NTP time transmitter or via IEEE1588, thereby simpli- (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
fying the assignment of diagnostic messages of multiple - Max. 10 m using patches with TP cord
devices.
• Link aggregation (IEEE 802.1q) for bundling data streams
• Quality of Service (IEEE 802.1p) for prioritization of network
traffic
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Function (continued)
Commissioning and diagnostics Network management
Setting options on the device itself: The network management provides the following functions:
• Redundancy manager RM; • Password-protected dial-up for "Administrator" (read and write
2 to establish a ring, a SCALANCE XR-300 is switched to RM
mode. The Gigabit ports (electrical or optical) are preferably
authorization) and "User" (read only)
• Read-out of version and status information
used as ring ports. The non-ring ports of the RM can be used
freely for the connection of data terminals and networks. If the • Setting the signal and standby mask and address information
redundancy procedure MRP standardized by PROFINET is • Fixed parameterization of the ports (data rates, half/full
used, the RM is adjusted automatically. duplex)
• Signal mask; • Setting of Spanning/Rapid Spanning Tree parameters
the signal mask is set to the current status of the • Parameterization of the web management services
SCALANCE XR-300 (setpoint) by pushbutton operation.
The signal mask defines which ports and which power • Security
supplies are to be monitored. The signaling contact only - Ports can be connected or disconnected
reports an error when a monitored port or a monitored feeder - Port-based network access control according to
fails (deviation of setpoint/actual status). IEEE 802.1x
- Authentication in accordance with IEEE 802.1x (available
• IP address; soon)
the IP address is assigned via DHCP (Dynamic Host Configu- - Support of Access Control List (ACL) (available soon)
ration Protocol). If there is no corresponding server in the
network, the IP address can be assigned using an enclosed • Output of statistics information
software tool. • Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
Diagnostic options on site:
• Loading of new firmware versions or of the configuration data
• The following status information is displayed by LEDs on site: via the network by a TFTP server or directly via HTTP/HTTPS
- Port status using a Web browser
- Port mode (10/100/1 000 Mbit/s, full/half-duplex)
- Status of the two power supplies • Saving the configuration data or log table via the network on a
- Signaling contact status TFTP server
- Signal mask (setpoint status) If faults occur in the network, the SCALANCE XR-300 switch can
- RM mode independently send error messages (traps) to a network man-
- Standby mode agement system or also e-mails to a predefined network admin-
• The status of the signaling contact is routed externally by istrator.
means of floating relay contacts. This enables, for example,
the module to be monitored via an input module from a Remote monitoring (RMON) provides the following functions:
controller. The SCALANCE XR-300 switch can collect statistics information
according to the RMON groups 1 through 4. These include, for
• Monitoring via the Industrial Ethernet network; example, fault statistics that are kept for each port. This informa-
the following possibilities are available: tion can be read out through web-based management in the
- Remote via standard browser (Web-based management): statistics sub-area.
Selection of SCALANCE XR-300 switches via the network
from a PC with browser
- Remote via SNMP V1, V2c, V3:
Secure integration of SCALANCE XR-300 switches via the
network into a network management system, e.g. SINEMA
Server
- Remote via PROFINET IO diagnostics:
PROFINET diagnostic alarms from SCALANCE X-300
switches can be displayed using the relevant SIMATIC
engineering tools and they can also be processed in the
controller. The engineering outlay for the PLC and HMI have
been drastically reduced due to the complete integration in
the SIMATIC concept for system error messages.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
■ Technical specifications
Article No. 6GK5324-4QG00-1AR2 6GK5324-4QG00-1HR2 6GK5324-4QG00-1CR2
Product-type designation SCALANCE XR324-4M POE SCALANCE XR324-4M POE SCALANCE XR324-4M POE TS
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 24 24 24
connections for network components
or terminal equipment maximum
Number of electrical connections
• for network components 16 16 16
and terminal equipment
• for Power-over-Ethernet for network 8 8 8
components or terminal equipment
• for operator console 1 1 1
• for signaling contact 1 1 1
• for media module 4 4 4
• for power supply 1 1 1
• for redundant power supply 1 1 0
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
• for Power-over-Ethernet for network RJ45 port RJ45 port RJ45 port
components or terminal equipment
• for operator console RJ11 port RJ11 port RJ11 port
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s Dependent on selected media Dependent on selected media Dependent on selected media
modules modules modules
• at 1 000 Mbit/s Dependent on selected media Dependent on selected media Dependent on selected media
modules modules modules
design of the removable storage Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage redundant No No No
power supply unit
Type of supply voltage DC DC DC
Supply voltage external 24 V 24 V 24 V
• minimum 19.2 V 19.2 V 19.2 V
• maximum 28.8 V 28.8 V 28.8 V
Product component fusing Yes Yes Yes
at power supply input
Type of fusing at input F 5 A / 250 V F 5 A / 250 V F 5 A / 250 V
for supply voltage
Consumed current maximum 4.2 A 4.2 A 4.2 A
Active power loss
• at 24 V for DC 46 W 46 W 46 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
2 Ambient temperature
• during operating -40 … +60 °C -40 … +60 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C
• Comment If the device is installed in the vertical If the device is installed in the vertical If the device is installed in the vertical
position, the maximum operating position, the maximum operating position, the maximum operating
temperature is reduced to 60 °C. temperature is reduced to 60 °C. temperature is reduced to 60 °C.
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) - - Conformal coating, yes
operation mode
Protection class IP IP20 IP20 IP20
Design, dimensions and weight
Design 19" rack 19" rack 19" rack
Width 449 mm 449 mm 449 mm
Height 43.6 mm 43.6 mm 43.6 mm
Depth 305 mm 305 mm 305 mm
Net weight 6.8 kg 6.8 kg 6.8 kg
Mounting type
• 19-inch installation Yes Yes Yes
• 35 mm DIN rail mounting No No No
• wall mounting No No No
• S7-300 rail mounting No No No
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
the device must be secured the device must be secured the device must be secured
in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points
Product properties, functions, com-
ponents general
Cascading in the case of a 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on signal Any (depending only on signal Any (depending only on signal
of star structuring propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes
• RMON Yes Yes Yes
• Port mirroring Yes Yes Yes
• CoS Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes
• switch-managed Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes
• broadcast blocking Yes Yes Yes
Protocol is supported SSH Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes
• SNTP Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A,
B, C, D / T4, Class 1, Zone 2, B, C, D / T4, Class 1, Zone 2, B, C, D / T4, Class 1, Zone 2,
Group IIC, T4 Group IIC, T4 Group IIC, T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4 EN 60079-15: 2005, II 3 G Ex nA II T4 EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X KEMA 07 ATEX 0145X KEMA 07 ATEX 0145X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 UL 1604 and UL 2279-15 UL 1604 and UL 2279-15
(Hazardous Location), CSA C22.2 No. (Hazardous Location), CSA C22.2 No. (Hazardous Location), CSA C22.2 No.
213-M1987, Class 1 / Division 2 / 213-M1987, Class 1 / Division 2 / 213-M1987, Class 1 / Division 2 /
Group A, B, C, D / T4, Class 1 / Group A, B, C, D / T4, Class 1 / Group A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4 Zone 2 / Group IIC / T4
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2006 EN 61000-6-2:2006 EN 61000-6-2:2006
Verification of suitability EN 61000-6-2:2006, EN 61000-6-2:2006, EN 61000-6-2:2006,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
Verification of suitability
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval No No No
• Railway application in accordance - - Yes
with EN 50155
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
2 components general
Cascading in the case of a 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any (depending only on signal propagation time) Any (depending only on signal propagation time)
of star structuring
Product functions management,
configuration
Product function
• CLI Yes Yes
• web-based management Yes Yes
• MIB support Yes Yes
• TRAPs via email Yes Yes
• Configuration with STEP 7 Yes Yes
• RMON Yes Yes
• Port mirroring Yes Yes
• CoS Yes Yes
• PROFINET IO diagnosis Yes Yes
• switch-managed Yes Yes
Protocol is supported
• Telnet Yes Yes
• HTTP Yes Yes
• HTTPS Yes Yes
• TFTP Yes Yes
• FTP Yes Yes
• BOOTP Yes Yes
• SNMP v1 Yes Yes
• SNMP v2 Yes Yes
• SNMP v3 Yes Yes
• IGMP (snooping/querier) Yes Yes
• GMRP Yes Yes
• DCP Yes Yes
• LLDP Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes
• I&M1 - higher level Yes Yes
designation/location designation
Product functions Diagnosis
Product function
• Port diagnostics Yes Yes
• Statistics packet size Yes Yes
• Statistics packet type Yes Yes
• Error statistics Yes Yes
• SysLog Yes Yes
Product functions VLAN
Product function
• VLAN - port based Yes Yes
• VLAN dynamic Yes Yes
Number of VLANs maximum 255 255
Number of VLANs - 255 255
dynamic maximum
Protocol is supported GVRP Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
■ Application (continued)
Operator station Operator station
2
Engineering station
Enhanced
SCALANCE SCALANCE Environmental
XR324-4M EEC XR324-4M EEC Conditions
G_IK10_XX_10278
SIPROTEC with IEEE 618501 protocol SIPROTEC with IEEE 618501 protocol
Electrical network structure in power switchgear with SCALANCE X-300EEC and XR324-4M EEC
■ Design
The SCALANCE X-300EEC Industrial Ethernet switches with The SCALANCE X-300EEC switches are available with the
rugged metal enclosure are optimized for mounting on a stan- following port types:
dard DIN rail. Thanks to the enclosure dimension 19"/2 (internal • As many as seven integrated fiber-optic ports for connecting
dimension), two devices can be mounted side by side in a the SCALANCE X switches with one another (multimode).
19" cabinet. The Fast Ethernet fiber optic ports are designed using LC
The switches have: connection technology.
• a 4-pin terminal block for connecting the redundant power • Up to seven integrated twisted pair ports;
supply (2 x 24 V DC) the RJ45 sockets are designed to be industry-compatible
with additional retaining mechanisms, for connection of the
• A 2-pin terminal block for connecting the isolated signaling Industrial Ethernet FC RJ45 Plug 180.
contact
• A row of LEDs to indicate the status information (power, link
status, data traffic, power supply, signaling contact)
• SELECT/SET key for on-site configuration of the signaling
contact
• Slot for optional C-PLUG swap medium on the top of the
device for easy replacement in the event of a fault
• Guide rails for strain-relief attachment of the RJ45 and LC
connection to the switch
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
■ Function
• Integrated redundancy manager for constructing ring topol- Network topology and network configuration
ogies with fast media redundancy Rings consisting of
SCALANCE X-300 and X-400 switches can be operated at 1 The SCALANCE X-300EEC Industrial Ethernet switches with
000 Mbit/s. In rings with SCALANCE X-200 or OSM/ESM it is degree of protection IP30 can be adapted to the structure of the
2
possible to integrate SCALANCE X-300EEC switches at plant in star, line and ring topologies.
100 Mbit/s. The following network structures and combinations of structures
• Redundant interfacing to corporate networks; can be implemented:
SCALANCE X-300EEC switches support the standardized • Fast Ethernet rings with fast media redundancy;
redundancy procedures Spanning Tree Protocol (STP) and to increase network availability, as many as 50 X-200, X-300,
Rapid Spanning Tree Protocol (RSTP). This enables a or X-400 switches cascaded in line can be connected into a
subnetwork to be connected redundantly to a higher level ring with a total length of up to 150 km. On the failure of a
corporate network with reduced requirements for the reconfig- transmission link or of a SCALANCE X switch in the ring, the
uration time (in the order of seconds). By supporting the transmission path is reconfigured within 0.3 seconds
Multiple Spanning Tree Protocol (MSTP), a network can also (0.2 seconds for MRP).
be split into multiple sub-segments. • Several rings can be redundantly linked through the standby
• Support of virtual networks (VLAN); function
for structuring Industrial Ethernet networks with a fast growing • Construction of interconnected network structures by means
number of users, a physically existing network can be divided of rapid spanning tree protocol (RSTP)
into several virtual networks.
• At the same time, SCALANCE X-300EEC supports redundant
• Load limiting when multicast protocols (e.g. Querier, video connection of the ring structure to the corporate network with
transmission) are used; a rapid spanning tree.
through learning the multicast sources and targets (IGMP
Snooping, IGMP Querier), SCALANCE X-300EEC switches • Star topology with SCALANCE X-300EEC switches:
can also filter multicast data traffic and therefore limit the load The SCALANCE X-300EEC switch represents a neutral point
in the network. that can connect up to nine nodes or subnets with each other.
• Time synchronization; When configuring the network, it is necessary to observe the
diagnostic messages (log table entries, e-mails) are time- following boundary conditions:
stamped. The local time is standardized throughout the • Maximum line length between two modules for multi-mode
network by means of synchronization with a SICLOCK time fiber-optic conductors:
transmitter, SNTP or NTP server or via IEEE1588, thereby - 5 000 m at 100 Mbit/s
simplifying the assignment of diagnostic messages of multiple
devices. • Maximum cable length of the TP cable between two
SCALANCE X switches:
• Fast replacement of devices in event of failure, by means of - max. 100 m
the C-PLUG switching medium
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
■ Function (continued)
Commissioning and diagnostics Network management
Setting options on the device itself: The network management provides the following functions:
• Redundancy manager RM; • Password-protected dial-up for "Administrator" (read and write
2 to establish a ring, a SCALANCE X-300EEC is switched to RM
mode. The non-ring ports of the RM can be used freely for the
authorization) and "User" (read only)
• Read-out of version and status information
connection of data terminals and networks. If the redundancy
procedure MRP standardized by PROFINET is used, the RM is • Setting the signal and standby mask and address information
adjusted automatically. • Parameterization of the web management services
• Signal mask; • Setting of Rapid Spanning Tree parameters
the signal mask is set to the current status of the • Fixed parameterization of the ports (data rates, half/full
SCALANCE X-300EEC (setpoint) by pushbutton operation. duplex)
The signal mask defines which ports and which power
supplies are to be monitored. The signaling contact only • Security
reports an error when a monitored port or a monitored feeder - Ports can be connected or disconnected
fails (deviation of setpoint/actual status). - Authentication in accordance with IEEE 802.1x (available
soon)
Diagnostic options on site: - Support of Access Control List (ACL) (available soon)
• The following status information is displayed by LEDs on site: • Parameterization of user administration of SNMP V1, V2c, V3
- Port status • Output of statistics information
- Port mode (10/100 Mbit/s, full/half-duplex)
- Status of the two power supplies • Diagnosis of data traffic by means of a parameterizable mirror
- Signaling contact status port with a standard commercial network analyzer
- Signal mask (setpoint status) • Loading new firmware updates or configuration data via the
- RM mode network from one TFTP server or directly via HTTP/HTTPs with
- Standby mode an Internet or Web browser.
• The status of the signaling contact is routed externally by • Saving the configuration data or log table via the network on a
means of floating relay contacts. This enables, for example, TFTP server
the module to be monitored via an input module from a
controller. If faults occur in the network, the SCALANCE X-300EEC switch
can independently send error messages (traps) to a network
• Monitoring via the Industrial Ethernet network; management system or also e-mails to a predefined network
the following possibilities are available: administrator.
- Remote via standard browser (Web-based management):
Selection of SCALANCE X-300 switches via the network from Remote monitoring (RMON) provides the following functions:
a PC with browser The SCALANCE X-300EEC switch can collect statistics informa-
- Remote via SNMP V1, V2c, V3: tion according to the RMON groups 1 through 4. These include,
Secure connection of SCALANCE X-300EEC switches via for example, fault statistics that are kept for each port. This
the network to a network management station information can be read out through web-based management in
- Remote via PROFINET IO diagnostics: the statistics sub-area.
PROFINET diagnostic alarms from SCALANCE X-300EEC
switches can be displayed using the relevant SIMATIC
engineering tools and they can also be processed in the
controller. The engineering outlay for the PLC and HMI have
been drastically reduced due to the complete integration in
the SIMATIC concept for system error messages.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
■ Technical specifications
Article No. 6GK5302-7GD00-1EA3 6GK5302-7GD00-1GA3 6GK5302-7GD00-2EA3 6GK5302-7GD00-2GA3
Product-type designation SCALANCE X302-7EEC SCALANCE X302-7EEC SCALANCE X302-7EEC SCALANCE X302-7EEC
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 9 9 9 9
connections for network components
or terminal equipment maximum
Number of electrical connections
• for network components 2 2 2 2
and terminal equipment
• for operator console - - - -
• for signaling contact 1 1 2 2
• for media module - - - -
• for power supply 1 1 2 2
• for redundant power supply 1 1 2 2
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port RJ45 port
and terminal equipment
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 2 x 4-pole terminal block 2 x 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 7 7 7 7
Design of optical interface
for optical waveguide
• at 100 Mbit/s LC port LC port LC port LC port
(multimode up to 5 km) (multimode up to 5 km) (multimode up to 5 km) (multimode up to 5 km)
Connectable optical power
relative to 1 mW
• of the transmitter output -19 … -14 dB -19 … -14 dB -19 … -14 dB -19 … -14 dB
• of the receiver input maximum -14 dB -14 dB -14 dB -14 dB
Optical sensitivity relative to 1 mW -32 dB -32 dB -32 dB -32 dB
of the receiver input minimum
Attenuation of fiber-optic cable 0 dB 0 dB 0 dB 0 dB
transmission link minimum necessary
Range at the optical interface 0 … 5 km 0 … 5 km 0 … 5 km 0 … 5 km
depending on the optical fiber used
Design of the removable storage Yes Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage redundant No No Yes Yes
power supply unit
Type of supply voltage DC DC DC DC
Type 2 of supply voltage DC DC DC DC
Supply voltage for DC 24 V 24 V 24 V 24 V
• rated value 19.2 … 57.6 V 19.2 … 57.6 V 19.2 … 57.6 V 19.2 … 57.6 V
Product component fusing Yes Yes Yes Yes
at power supply input
Type of fusing at input T 4 A / 125 V T 4 A / 125 V T 4 A / 125 V T 4 A / 125 V
for supply voltage
Consumed current maximum 0.75 A 0.75 A 0.75 A 0.75 A
Active power loss
• at 24 V for DC 17 W 17 W 17 W 17 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• Comment A maximum operating A maximum operating A maximum operating A maximum operating
temperature of +85 °C temperature of +85 °C temperature of +85 °C temperature of +85 °C
is permissible for a duration is permissible for a duration is permissible for a duration is permissible for a duration
of 16 hours of 16 hours of 16 hours of 16 hours
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) Conformal coating, no Conformal coating, yes Conformal coating, no Conformal coating, yes
operation mode
Protection class IP IP30 IP30 IP30 IP30
Design, dimensions and weight
Design compact compact compact compact
Width 216 mm 216 mm 216 mm 216 mm
Height 143 mm 143 mm 143 mm 143 mm
Depth 110 mm 110 mm 110 mm 110 mm
Net weight 1.8 kg 1.8 kg 2.03 kg 1.8 kg
Mounting type
• 19-inch installation Yes Yes Yes Yes
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Mounting type Wall mounting is possible Wall mounting is possible Wall mounting is possible Wall mounting is possible
only with an additional wall only with an additional wall only with an additional wall only with an additional wall
bracket; 19" mounting only bracket; 19" mounting only bracket; 19" mounting only bracket; 19" mounting only
with installation of two with installation of two with installation of two with installation of two
X-300EEC switches in pairs X-300EEC switches in pairs X-300EEC switches in pairs X-300EEC switches in pairs
using a mounting plate using a mounting plate using a mounting plate using a mounting plate
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any Any Any Any
of star structuring (depending only on signal (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• for IRT PROFINET IO switch No No No No
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 nA II T4 nA II T4 nA II T4
• for safety of CSA and UL UL 508 UL 508 UL 508 UL 508
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01,
CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987,
UL 1604 and 2279-15, UL 1604 and 2279-15, UL 1604 and 2279-15, UL 1604 and 2279-15,
CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D
T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC,
T4 T4 T4 T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
• IEC 61850-3 Yes Yes Yes Yes
Certificate of suitability IEEE 1613 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Product function
• Ring redundancy Yes Yes Yes Yes
• Redundancy manager Yes Yes Yes Yes
• Standby redundancy Yes Yes Yes Yes
• High Speed Redundancy Protocol Yes Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes Yes
• Redundancy procedure STP Yes Yes Yes Yes
• RSTP redundancy protocol Yes Yes Yes Yes
• Redundancy procedure MSTP Yes Yes Yes Yes
• Passive listening Yes Yes Yes Yes
Protocol is supported
• STP/RSTP Yes Yes Yes Yes
• STP Yes Yes Yes Yes
• RSTP Yes Yes Yes Yes
• RSTP big network support Yes Yes Yes Yes
• LACP Yes Yes Yes Yes
Product functions Security
Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• Broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for safety of CSA and UL UL 508, UL 508, UL 508, UL 508,
CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
• IEC 61850-3 Yes Yes Yes Yes
certificate of suitability IEEE 1613 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during transport -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• Comment A maximum operating A maximum operating A maximum operating A maximum operating
temperature of +85 °C temperature of +85 °C temperature of +85 °C temperature of +85 °C
is permissible for a duration is permissible for a duration is permissible for a duration is permissible for a duration
of 16 hours of 16 hours of 16 hours of 16 hours
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) Conformal coating, no Conformal coating, yes Conformal coating, no Conformal coating, yes
operation mode
Protection class IP IP30 IP30 IP30 IP30
Design, dimensions and weight
Design compact compact compact compact
Width 216 mm 216 mm 216 mm 216 mm
Height 143 mm 143 mm 143 mm 143 mm
Depth 110 mm 110 mm 110 mm 110 mm
Net weight 1.8 kg 1.8 kg 2.03 kg 2.03 kg
Mounting type
• 19-inch installation Yes Yes Yes Yes
• 35 mm DIN rail mounting Yes Yes Yes Yes
• wall mounting Yes Yes Yes Yes
• S7-300 rail mounting Yes Yes Yes Yes
Mounting type Wall mounting is possible Wall mounting is possible Wall mounting is possible Wall mounting is possible
only with an additional wall only with an additional wall only with an additional wall only with an additional wall
bracket; 19" mounting only bracket; 19" mounting only bracket; 19" mounting only bracket; 19" mounting only
with installation of two with installation of two with installation of two with installation of two
X-300EEC switches in pairs X-300EEC switches in pairs X-300EEC switches in pairs X-300EEC switches in pairs
using a mounting plate using a mounting plate using a mounting plate using a mounting plate
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any Any Any Any
of star structuring (depending only on signal (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• SMTP server - - - -
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• for IRT PROFINET IO switch No No No No
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 nA II T4 nA II T4 nA II T4
• for safety of CSA and UL UL 508 UL 508 UL 508 UL 508
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01,
CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987, CSA C22.2 No. 213-M1987,
UL 1604 and 2279-15, UL 1604 and 2279-15, UL 1604 and 2279-15, UL 1604 and 2279-15,
CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D
T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC,
T4 T4 T4 T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
• IEC 61850-3 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2 Product function
• Ring redundancy Yes Yes Yes Yes
• Redundancy manager Yes Yes Yes Yes
• Standby redundancy Yes Yes Yes Yes
• High Speed Redundancy Protocol Yes Yes Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes Yes Yes
• redundancy procedure STP Yes Yes Yes Yes
• RSTP redundancy protocol Yes Yes Yes Yes
• redundancy procedure MSTP Yes Yes Yes Yes
• Passive listening Yes Yes Yes Yes
Protocol is supported
• STP/RSTP Yes Yes Yes Yes
• STP Yes Yes Yes Yes
• RSTP Yes Yes Yes Yes
• RSTP big network support Yes Yes Yes Yes
• LACP Yes Yes Yes Yes
Product functions Security
Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for safety of CSA and UL UL 508, UL 508, UL 508, UL 508,
CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987 CSA C22.2 No. 142-M1987
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• Railway application in accordance No No No No
with EN 50155
• Railway application in accordance No No No No
with EN 50124-1
• IEC 61850-3 Yes Yes Yes Yes
Certificate of suitability IEEE 1613 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2
and/or optical Industrial Ethernet
networks; RSTP, RMON, IGMP 4-core, shielded TP installation
Snooping/Querier, management cable for connection to
functionality via SNMP, IE FC Outlet RJ45/IE FC RJ45 Plug;
PROFINET and web server, PROFINET compatible;
24 V power supply with UL approval;
sold by the meter;
SCALANCE X302-7EEC; max. length 1 000 m,
2 x 10/100/1 000 Mbit/s minimum order length 20 m
RJ45 ports, electrical;
7 x 100 Mbit/s LC ports, optical IE FC TP standard cable GP 4 x 2
(multimode, glass) 8-core, shielded TP installation
up to 5 km cable for connection to IE FC RJ45
24 V DC power supply modular outlet for universal applica-
tion; with UL approval;
• 1 power supply 6GK5302-7GD00-1EA3 sold by the meter;
• 2 power supplies 6GK5302-7GD00-2EA3 max length 1 000 m,
• 1 power supply 6GK5302-7GD00-1GA3 minimum order 20 m
with conformal coating • AWG 22, 6XV1870-2E
• 2 power supplies 6GK5302-7GD00-2GA3 for connection to
with conformal coating IE FC RJ45 Modular Outlet
100-240 AC / 60-250 V DC • AWG 24, 6XV1878-2A
power supply for connection to
IE FC RJ45 Plug 4 x 2
• 1 power supply 6GK5302-7GD00-3EA3
• 2 power supplies 6GK5302-7GD00-4EA3 IE FC TP Flexible Cable GP 4 x 2
• 1 power supply 6GK5302-7GD00-3GA3 8-core, shielded TP installation
with conformal coating cable for occasional moving;
• 2 power supplies 6GK5302-7GD00-4GA3 with UL approval;
with conformal coating sold by the meter;
max. delivery unit 1 000 m,
SCALANCE X307-2EEC; minimum order 20 m
5 x 10/100 Mbit/s
• AWG 24, 6XV1878-2B
RJ45 ports, electrical;
for connection to
2 x 10/100/1 000 Mbit/s
IE FC RJ45 Plug 4 x 2
RJ45 ports, electrical
2 x 100 Mbit/s IE TP Cord RJ45/RJ45
LC ports, optical (multimode, glass)
up to 5 km TP cable 4 x 2
with two RJ45 plugs
24 V DC power supply • 0.5 m 6XV1870-3QE50
• 1 power supply 6GK5307-2FD00-1EA3 •1m 6XV1870-3QH10
• 2 power supplies 6GK5307-2FD00-2EA3 •2m 6XV1870-3QH20
• 1 power supply with conformal 6GK5307-2FD00-1GA3 •6m 6XV1870-3QH60
coating
• 10 m 6XV1870-3QN10
• 2 power supplies with conformal 6GK5307-2FD00-2GA3
coating
100-240 AC/60-250 V DC
power supply
• 1 power supply 6GK5307-2FD00-3EA3
• 2 power supplies 6GK5307-2FD00-4EA3
• 1 power supply with conformal 6GK5307-2FD00-3GA3
coating
• 2 power supplies with conformal 6GK5307-2FD00-4GA3
coating
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
■ Overview ■ Benefits
SCALANCE XR324-4M EEC (4 media module slots) The main area of application is found in high-performance
plant networks with interfaces to the corporate network.
Versions are available with Thanks to the immunity to electromagnetic interference of the
• LEDs, data cable outlet on the front and power supply SCALANCE XR-300EEC switches, the devices can also be used
connection at the rear in medium/high voltage substations.
• LEDs, power supply connection on the front, data cable outlet The SCALANCE XR-300EEC switch is suitable for establishing
at the rear optical Industrial Ethernet line, star or ring topologies with
24 ports, 16 of which are integrated RJ45 ports. Up to four
All versions have four media module slots and electrical and/or optical 2-port media modules can also be
• 1 x 24 V DC power supply inserted in the media module slots of the basic device.
• 2 x 24 V DC power supplies The switch can also be used as a hub in the plant bus (redun-
dant connection is possible).
• 1 x 230 V AC power supply
• 2 x 230 V AC power supplies The use of media modules in partly and fully modular versions of
the SCALANCE X-300 switches supports:
• Extension of networks by subsequent insertion of additional
media modules in unused media module slots
• Changing of cabling technology, such as conversion from
copper to fiber-optic cables, or from multimode to single-
mode FOC
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
■ Application (continued)
S7-400
Operator station
2 PC
SCALANCE XR324-4MEEC
PROFINET
Industrial Ethernet
SCALANCE SCALANCE
X307-2EEC X307-2EEC
SIPLUS SIPLUS
ET 200S ET 200S
G_IK10_XX_10279
Environment with extreme Location with adverse
temperatures environmental conditions
(e.g. gaseous atmosphere)
Star structure in switchgear under extreme ambient conditions with SCALANCE XR324-4M EEC and X-300EEC
■ Design
The SCALANCE XR-300EEC Industrial Ethernet switches The SCALANCE XR-300EEC switches are available with the
with rugged metal enclosure with IP20 degree of protection are following port types:
optimized for installation in the 19" cabinet. • 16 integrated RJ45 ports;
The switches have: The RJ45 sockets are designed to be industry-compatible
with additional sleeves, for connection of the Industrial
• 4-pin terminal block for redundant voltage feed for protection Ethernet FC RJ45 Plug 180
against voltage failure in 24 V DC version
• Four slots for electrical or optical 2-port media modules for
• 3-pin terminal block for voltage feed in 230 V AC version multimode or single-mode connections; the optical media
• 2-pin terminal block for connecting the isolated signaling modules are available in various connection technologies
contact for simple display of faults • All electrical Ethernet interfaces support 10/100/1 000 Mbit/s,
• A row of LEDs to indicate the status information (power, link all optical Ethernet interfaces support 100 or 1 000 Mbit/s
status, data traffic, power supply, signaling contact) • The SCALANCE XR-300EEC switches support Gigabit
• SELECT/SET pushbutton for simple adjustment of the fault Ethernet (1 000 Mbit/s) at all ports.
signaling contact on the device The 24 ports are divided into three groups of eight ports each
• Slot for optional C-PLUG swap medium on the side of the (Gigabit Ethernet Blocking). Gigabit Ethernet is supported
device for easy replacement in the event of a fault with full wire speed within each group, but not between the
groups.
• Console port (serial interface) for on-site parameterization/
diagnostics (RJ11 cable to RS232 (9-pin) included in scope of
delivery)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
■ Function
• Integrated redundancy manager for constructing Fast Network topology and network configuration
Ethernet and Gigabit Ethernet ring topologies with high-speed
media redundancy. Reliable communication is achieved by The network topology can easily be adapted to the structure of
closing an optical or electrical line with SCALANCE X-400, the plant using SCALANCE XR-300 Industrial Ethernet switches .
X-300 or X-200 switches to form a ring. The redundancy
manager (RM) integrated in the SCALANCE XR-300 switch
The following network structures and combinations of structures
can be implemented:
2
monitors the function of the network. It recognizes the failure • Fast Ethernet rings with fast media redundancy;
of a transmission link or of SCALANCE X switch in the ring and to increase network availability, as many as 50 X-200, X-300,
activates the substitute path within a maximum of 0.2 X-400 or X-500 switches cascaded in line can be connected
seconds. into a ring.
• Redundant interfacing to corporate networks; • Several rings can be redundantly linked through the standby
SCALANCE XR-300EEC switches support the standardized function
redundancy procedures Spanning Tree Protocol (STP) and
Rapid Spanning Tree Protocol (RSTP). This enables a • At the same time, SCALANCE XR-300EEC supports
subnetwork to be connected redundantly to a higher level redundant connection of the ring structure to the corporate
corporate network with reduced requirements for the reconfig- network with a rapid spanning tree.
uration time (in the order of seconds). By supporting the • Star topology with SCALANCE XR-300EEC switches:
Multiple Spanning Tree Protocol (MSTP), a network can also The SCALANCE XR-300EEC switch represents a neutral point
be split into multiple sub-segments. that can interconnect up to 24 nodes or subnets electrically.
• Support of virtual networks (VLAN); When configuring the network, it is necessary to observe the
for structuring Industrial Ethernet networks with a fast growing following boundary conditions:
number of users, a physically existing network can be divided
into several virtual networks. • Maximum line length between two modules for multi-mode
fiber-optic conductors:
• Load limiting when multicast protocols (e.g. video trans- - 5 km at 100 Mbit/s
mission) are used; - 750 m at 1 000 Mbit/s
through learning the multicast sources and targets (IGMP
Snooping, IGMP Querier), SCALANCE XR-300EEC switches • Maximum line length between two modules for single-mode
can also filter multicast data traffic and therefore limit the load fiber-optic conductors:
in the network. Multicast and broadcast traffic can be limited. - 26 to 70 km at 100 Mbit/s
- 10 to 120 km at 1 000 Mbit/s
• Time synchronization;
diagnostic messages (log table entries, e-mails) are time- • Maximum cable length of the TP cable between two
stamped. The local time is standardized throughout the SCALANCE X switches:
network by means of synchronization with a SICLOCK time - Max. 100 m with IE FC cable 2x2 and IE FC RJ45 Plug 180
transmitter, SNTP or NTP server or via IEEE1588, thereby - Max. 100 m at 1 000 Mbit/s with IE FC Standard Cable 4x2
simplifying the assignment of diagnostic messages of multiple (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
devices. - Max. 10 m using patches with TP cord
• Fast replacement of devices in event of failure, by means of
the C-PLUG switching medium
• Link aggregation (IEEE 802.1q) for bundling data streams
• Quality of Service (IEEE 802.1p) for prioritization of network
traffic
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
■ Function (continued)
Commissioning and diagnosis Network management
Setting options on the device itself: The network management provides the following functions:
• Redundancy manager RM; • Password-protected dial-up for "Administrator" (read and write
2 to establish a ring, a SCALANCE XR-300EEC is switched to
RM mode. The Gigabit ports (electrical or optical) are
authorization) and "User" (read only)
• Read-out of version and status information
preferably used as ring ports. The non-ring ports of the RM
can be used freely for the connection of data terminals and • Setting the signal and standby mask and address information
networks. If the redundancy procedure MRP standardized by • Parameterization of the web management services
PROFINET is used, the RM is adjusted automatically. • Setting of Rapid Spanning Tree parameters
• Signal mask; • Fixed parameterization of the ports (data rates, half/full
the signal mask is set to the current status of the duplex)
SCALANCE XR-300EEC (setpoint) by pushbutton operation.
The signal mask defines which ports and which power • Security
supplies are to be monitored. The signaling contact only - Ports can be connected or disconnected
reports an error when a monitored port or a monitored feeder - Port-based network access control according to
fails (deviation of setpoint/actual status). IEEE 802.1x (available soon)
- Support of Access Control List (ACL) (available soon)
• IP address;
the IP address is assigned via DHCP (Dynamic Host Configu- • Output of statistics information
ration Protocol). If there is no corresponding server in the • Diagnosis of data traffic by means of a parameterizable mirror
network, the IP address can be assigned using an enclosed port with a standard commercial network analyzer
software tool. • Loading of new firmware versions or of the configuration data
Diagnostic options on site: via the network by a TFTP server or directly via HTTP/HTTPS
using a Web browser
• The following status information is displayed by LEDs on site:
- Port status • Saving the configuration data or log table via the network on a
- Port mode (10/100/1 000 Mbit/s, full/half-duplex) TFTP server
- Status of the two power supplies If faults occur in the network, the SCALANCE XR-300EEC switch
- Signaling contact status can independently send error messages (traps) to a network
- Signal mask (setpoint status) management system or also e-mails to a predefined network
- RM mode administrator.
- Standby mode
• The status of the signaling contact is routed externally by Remote monitoring (RMON) provides the following functions:
means of floating relay contacts. This enables the module to The SCALANCE X-300EEC switch can collect statistics informa-
be monitored via an input module from a controller. tion according to the RMON groups 1 through 4. These include,
for example, fault statistics that are kept for each port. This
• Monitoring via the Industrial Ethernet network; information can be read out through web-based management in
the following possibilities are available: the statistics sub-area.
- Remote via standard browser (Web-based management):
Selection of SCALANCE XR-300EEC switches via the
network from a PC with browser
- Remote via SNMP V1, V2c, V3:
Secure integration of SCALANCE XR-300EEC switches via
the network to a network management system, e.g. SINEMA
Server
- Remote via PROFINET IO diagnostics:
PROFINET diagnostic alarms from SCALANCE XR-300EEC
switches can be displayed using the relevant SIMATIC
engineering tools and they can also be processed in the
controller. The engineering outlay for the PLC and HMI have
been drastically reduced due to the complete integration in
the SIMATIC concept for system error messages.
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
■ Technical specifications
Article No. 6GK5324-4GG00-1ER2 6GK5324-4GG00-1JR2 6GK5324-4GG00-2ER2 6GK5324-4GG00-2JR2
Product-type designation SCALANCE XR324-4M EEC SCALANCE XR324-4M EEC SCALANCE XR324-4M EEC SCALANCE XR324-4M EEC
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 24 24 24 24
connections for network components
or terminal equipment maximum
Number of electrical connections
• for network components 16 16 16 16
and terminal equipment
• for operator console 1 1 1 1
• for signaling contact 1 1 1 1
• for media module 4 4 4 4
• for power supply 1 1 2 2
• for redundant power supply 1 1 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port RJ45 port
and terminal equipment
• for operator console RJ11 port RJ11 port RJ11 port RJ11 port
• for signaling contact 2-pole terminal block 2-pole terminal block 2 x 2-pole terminal block 2 x 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 2 x 4-pole terminal block 2 x 4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s Dependent on selected Dependent on selected Dependent on selected Dependent on selected
media modules media modules media modules media modules
• at 1 000 Mbit/s Dependent on selected Dependent on selected Dependent on selected Dependent on selected
media modules media modules media modules media modules
design of the removable storage Yes Yes Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage No No Yes Yes
redundant power supply unit
Type of supply voltage DC DC DC DC
Type 2 of supply voltage DC DC DC DC
Supply voltage for DC 24 V 24 V 24 V 24 V
• rated value 19.2 … 57.6 V 19.2 … 57.6 V 19.2 … 57.6 V 19.2 … 57.6 V
Product component fusing Yes Yes Yes Yes
at power supply input
Type of fusing at input T2H / 250 V T2H / 250 V T2H / 250 V T2H / 250 V
for supply voltage
Consumed current maximum 1.6 A 1.6 A 1.6 A 1.6 A
Active power loss
• at 24 V for DC 40 W 40 W 40 W 40 W
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C -40 … +85 °C
• Comment Extended temperature upper Extended temperature upper Extended temperature upper Extended temperature upper
limit of +85° C permitted for limit of +85° C permitted for limit of +85° C permitted for limit of +85° C permitted for
16 hours. Reduced operat- 16 hours. Reduced operat- 16 hours. Reduced operat- 16 hours. Reduced operat-
ing temperature through ing temperature through ing temperature through ing temperature through
the use of media modules the use of media modules the use of media modules the use of media modules
(-40 °C to +70 °C) or (-40 °C to +70 °C) or (-40 °C to +70 °C) or (-40 °C to +70 °C) or
SFP plug-in transceivers SFP plug-in transceivers SFP plug-in transceivers SFP plug-in transceivers
(-40 °C to +60 °C) (-40 °C to +60 °C) (-40 °C to +60 °C) (-40 °C to +60 °C)
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP20 IP20 IP20 IP20
Design, dimensions and weight
Design 19" rack 19" rack 19" rack 19" rack
Width 483 mm 483 mm 483 mm 483 mm
Height 44 mm 44 mm 44 mm 44 mm
Depth 305 mm 305 mm 305 mm 305 mm
Net weight 6.5 kg 6.5 kg 6.8 kg 6.8 kg
Mounting type
• 19-inch installation Yes Yes Yes Yes
• 35 mm DIN rail mounting No No No No
• wall mounting No No No No
• S7-300 rail mounting No No No No
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
the device must be secured the device must be secured the device must be secured the device must be secured
in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points
Product properties, functions, com-
ponents general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any Any Any Any
of star structuring (depending only on signal (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• for IRT PROFINET IO switch - - - -
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for EMC from FM FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2, FM3611: Class 1, Division 2,
Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC, Class 1, Zone 2, Group IIC,
T4 T4 T4 T4
• for hazardous zone EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006, EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex EN 60079-15: 2005, II 3 G Ex
nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX nA II T4 KEMA 07 ATEX
0145X 0145X 0145X 0145X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03
• for hazardous area of CSA and UL ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01, ANSI / ISA 12.12.01,
CSA C22.2 No. 142-M1987, CSA C22.2 No. 142-M1987, CSA C22.2 No. 142-M1987, CSA C22.2 No. 142-M1987,
CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D CL. 1 / Div. 2 / GP. A, B, C, D
T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC, T4, CL. 1 / Zone 2 / GP. IIC,
T4 T4 T4 T4
• for emitted interference EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
(Class A) (Class A) (Class A) (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• IEC 61850-3 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C -40 … +85 °C
• Comment Extended temperature upper Extended temperature upper Extended temperature upper Extended temperature upper
limit of +85° C permitted for limit of +85° C permitted for limit of +85° C permitted for limit of +85° C permitted for
16 hours. Reduced operat- 16 hours. Reduced operat- 16 hours. Reduced operat- 16 hours. Reduced operat-
ing temperature through ing temperature through ing temperature through ing temperature through
the use of media modules the use of media modules the use of media modules the use of media modules
(-40 °C to +70 °C) or (-40 °C to +70 °C) or (-40 °C to +70 °C) or (-40 °C to +70 °C) or
SFP plug-in transceivers SFP plug-in transceivers SFP plug-in transceivers SFP plug-in transceivers
(-40 °C to +60 °C) (-40 °C to +60 °C) (-40 °C to +60 °C) (-40 °C to +60 °C)
Relative humidity at 25 °C without 95 % 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP20 IP20 IP20 IP20
Design, dimensions and weight
Design 19" rack 19" rack 19" rack 19" rack
Width 483 mm 483 mm 483 mm 483 mm
Height 44 mm 44 mm 44 mm 44 mm
Depth 305 mm 305 mm 305 mm 305 mm
Net weight 6.6 kg 6.6 kg 7 kg 7 kg
Mounting type
• 19-inch installation Yes Yes Yes Yes
• 35 mm DIN rail mounting No No No No
• wall mounting No No No No
• S7-300 rail mounting No No No No
Mounting type When used in shipbuilding, When used in shipbuilding, When used in shipbuilding, When used in shipbuilding,
the device must be secured the device must be secured the device must be secured the device must be secured
in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points in the 19" rack at four points
Product properties, functions,
components general
Cascading in the case of a 50 50 50 50
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases of star structuring Any Any Any Any
(depending only on signal (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes Yes
• web-based management Yes Yes Yes Yes
• MIB support Yes Yes Yes Yes
• TRAPs via email Yes Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes Yes
• RMON Yes Yes Yes Yes
• SMTP server - - - -
• Port mirroring Yes Yes Yes Yes
• CoS Yes Yes Yes Yes
• for IRT PROFINET IO switch - - - -
• PROFINET IO diagnosis Yes Yes Yes Yes
• switch-managed Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
2 Product function
• ACL - port/MAC-based Yes Yes Yes Yes
• IEEE 802.1x (radius) Yes Yes Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes Yes Yes
• Broadcast blocking Yes Yes Yes Yes
Protocol is supported SSH Yes Yes Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes Yes Yes
Protocol is supported
• NTP Yes Yes Yes Yes
• SNTP Yes Yes Yes Yes
• MSTP Yes Yes Yes Yes
• IEEE 1588 profile default Yes Yes Yes Yes
Standards, specifications,
approvals
Standard
• for EMC IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613 IEC 61850, IEEE 1613
• for EMC from FM No No No No
• for hazardous zone No No No No
• for safety of CSA and UL UL 508, CSA C22.2 UL 508, CSA C22.2 UL 508, CSA C22.2 UL 508, CSA C22.2
No. 142-M1987 No. 142-M1987 No. 142-M1987 No. 142-M1987
• for hazardous area of CSA and UL No No No No
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes Yes
• C-Tick Yes Yes Yes Yes
• KC approval Yes Yes Yes Yes
• IEC 61850-3 Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Overview ■ Benefits
■ Application
The use of media modules in partly and fully modular versions of
the SCALANCE X-300 switches or selected SCALANCE S de-
vices supports:
• Extension of networks by subsequent insertion of additional
media modules in unused media module slots
• Changing of the cabling technology (e.g. conversion from
copper to fiber-optic cables, or from multi-mode to single-
• 2-port media modules for flexible, 2-port-granular equipping mode FOC)
of partly and fully modular versions of • Bridging of longer cable runs or use of existing 2-wire cables
SCALANCE X-300 switches (e.g. SCALANCE X308-2M, (variable distance)
SCALANCE XR324-12M) as well as the SCALANCE S627-2M
• Electrical versions with RJ45 ports are available as well as Media module IE FC TP Standard Cable 0 ... 500 m at 100 Mbit/s
optical versions with BFOC and SC ports for the use of MM992-2VD GP 4x2 (AWG24)
(in VD mode) with IE FC RJ45 plug 4x2
multimode and singlemode fiber-optic cables
Standard IE FC TP cable 0 ... 300 m at 100 Mbit/s
• A 2-port SFP media module permits the optional use of fiber- GP 2x2 (AWG22/1)
optic SFP plug-in transceivers (Small Form-Factor Pluggable) with IE FC RJ45 plug 2x2
with LC connection technology. Versions with coated PCBs
IE FC TP Standard Cable 300 ... 500 m at 10 Mbit/s
(conformal coating) for railway applications are also available. 2x2 (AWG22/1)
with IE FC RJ45 plug 2x2
PROFIBUS FC Standard 100 ... 1 000 m at 10 Mbit/s
Cable GP
with IE FC RJ45 plug 4x2
PROFIBUS FC Standard 0 ... 100 m at 100 Mbit/s
Cable GP
with IE FC RJ45 plug 4x2
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Design
Optical
2-port media modules are
inserted into the device
G_IK10_XX_10282
Electrical Optical
2-port media modules are SFP pluggable transceivers
inserted into the device (one port) are inserted into the
SFP media module
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Design (continued)
Product versions of SFP pluggable transceivers Optical SFP pluggable transceivers with
1 x 1 000 Mbit/s LC port
The SFP plug-in transceivers (Small Form-factor Pluggable) can
only be used together with the SFP media module MM992-2SFP. • SFP992-1
multimode, glass, up to 750 m
2 Optical SFP pluggable transceivers with
1 x 100 Mbit/s LC port • SFP992-1LD
singlemode, glass, up to 10 km
• SFP991-1
multimode, glass, up to 5 km • SFP992-1LH
singlemode, glass, up to 40 km
• SFP991-1LD
singlemode, glass, up to 26 km • SFP992-1LH+
singlemode, glass, up to 70 km
• SFP991-1LH+
singlemode, glass, up to 70 km • SFP992-1ELH
singlemode, glass, up to 120 km
• SFP991-1ELH200
singlemode, glass, up to 200 km
Port-Typ
Type andund
quantity
Anzahlof ports
SFP992-1LD 1x LC 10 km
SFP992-1LH 1x LC 40 km
SFP992-1LH+ 1x LC 70 km
SFP992-1ELH 1x LC 120 km
1)
1) with
mit Haltekragen
retaining collars Cansteckbar
3) nur only be plugged into an mit
in Kombination MM392-2SFP
SFP- (C) Conformal Coating
2)
2) The MM392-2SFP SFP slot
das SFP-Schachtmodul module cankann in
MM392-2SFP slot module
Schachtmodul MM392-2SFP see media
* siehe modules
Handbuch manual
Medienmodule
accommodate
Summe max. 2xup1-Port-SFP-Module
to two 1-port SFP modules
aufnehmen X-coded
4) M12 X-kodiert
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Integration
SCALANCE
Integration in existing complex Bulkhead SCALANCE X308-2M
XR324-12M
firewall with media module Terminals
with media module
MM992-2VD ET 200M
MM992-2VD
SCALANCE S627-2M
with media module
nprXWXWZ^[
MM992-2VD
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Technical specifications
Article No. 6GK5992-2GA00-8AA0 6GK5992-2GA00-8FA0 6GK5992-2SA00-8AA0
Product-type designation MM992-2CUC MM992-2CUC MM992-2CU
Interfaces
2 Number of electrical/optical
connections for network components
2 2 2
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
2 Number of electrical/optical
connections for network components
2 2
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
2 Number of electrical/optical
connections for network components
2 2 2 2
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
2 Number of electrical/optical
connections for network components
1 1 1 1
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
2 Number of electrical/optical
connections for network components
1 1
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
6GK5992-2GA00-8FA0
• SFP991-1
multimode, glass, up to 5 km
• SFP991-1LD
6GK5991-1AD00-8AA0
6GK5991-1AF00-8AA0
2
with retaining sleeve and coated singlemode, glass, up to 26 km
PCBs (conformal coating) • SFP991-1LH+ 6GK5991-1AE00-8AA0
• MM992-2CU 6GK5992-2SA00-8AA0 singlemode, glass, up to 70 km
without retaining sleeve • SFP991-1ELH200 6GK5991-1AE30-8AA0
with 2 x 10/100/1 000 Mbit/s singlemode, glass, up to 200 km
M12 ports, electrical with 1 x 1 000 Mbit/s
• MM992-2 M12 interface (x-coded) 6GK5992-2HA00-0AA0 LC port, optical
and coated PCBs (conformal • SFP992-1 6GK5992-1AL00-8AA0
coating) multimode, glass, up to 750 m
with 2 x 1/10/100/1 000 Mbit/s • SFP992-1LD 6GK5992-1AM00-8AA0
RJ45 ports, electrical singlemode, glass, up to 10 km
• MM992-2VD 6GK5992-2VA00-8AA0 • SFP992-1LH 6GK5992-1AN00-8AA0
singlemode, glass, up to 40 km
Fiber optic modules • SFP992-1LH+ 6GK5992-1AP00-8AA0
with 2 x 100 Mbit/s singlemode, glass, up to 70 km
BFOC ports, optical • SFP992-1ELH 6GK5992-1AQ00-8AA0
• MM991-2 6GK5991-2AB00-8AA0 singlemode, glass, up to 120 km
multimode, glass, up to 5 km Accessories
• MM991-2LD 6GK5991-2AC00-8AA0
singlemode, glass, up to 26 km IE FC RJ45 Modular Outlet
with 2 x 100 Mbit/s FastConnect RJ45 outlet
SC ports, optical for Industrial Ethernet with interface
• MM991-2 6GK5991-2AD00-8AA0 for replaceable insert
multimode, glass, up to 5 km • with insert 2FE; 6GK1901-1BE00-0AA1
• MM991-2LD 6GK5991-2AF00-8AA0 replaceable insert for
singlemode, glass, up to 26 km 2 x 100 Mbit/s interfaces
• MM991-2LH+ 6GK5991-2AE00-8AA0 • with 1GE insert; 6GK1901-1BE00-0AA2
singlemode, glass, up to 70 km replaceable insert for
1 x 1 000 Mbit/s interfaces
with 2 x 1 000 Mbit/s
SC ports, optical IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
(Type A)
• MM992-2 6GK5992-2AL00-8AA0
multimode, glass, up to 750 m 4-core, shielded TP installation
• MM992-2 6GK5992-2AL00-8FA0 cable for connection to
multimode, glass, up to 750 m, IE FC Outlet RJ45/IE FC RJ45 Plug;
coated PCBs (conformal coating) PROFINET-compatible;
• MM992-2LD 6GK5992-2AM00-8AA0 with UL approval;
singlemode, glass, up to 10 km sold by the meter;
max. length 1 000 m,
• MM992-2LH 6GK5992-2AN00-8AA0 minimum order quantity 20 m
singlemode, glass, up to 40 km
• MM992-2LH+ 6GK5992-2AP00-8AA0 IE FC TP Standard Cable GP 4 x 2 6XV1870-2E
singlemode, glass, up to 70 km 8-core, shielded TP installation
• MM992-2ELH 6GK5992-2AQ00-8AA0 cable for connection to
singlemode, glass, up to 120 km IE FC RJ45 modular outlet for
universal application;
with 2 x 100/1 000 Mbit/s
with UL approval;
for SFP pluggable transceiver,
sold by the meter;
optical
max length 1 000 m,
• MM992-2SFP 6GK5992-2AS00-8AA0 minimum order 20 m
for SFP pluggable transceivers
with 1 x 100 or 1 x 1 000 Mbit/s
multimode or singlemode, glass
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
Media modules for modular SCALANCE X-300 managed
■ Overview
device
PE408
X408-2
X408-2
Type of
● applies
X414-3E
X414-3E
XM408-4C
XM408-8C
XM416-4C
XM408-4C
XM408-8C
XM416-4C
PE408 PoE
PE400-8SFP
Security Integrated (Firewall/VPN) Connection to S7 backplane bus
●
●
●
●
●
●
●
●
●
●
●
PROFINET diagnosis Format module S7
Software
●
●
●
●
●
Hardware
●
●
●
●
●
Command Line Interface / Telnet Flat type of construction
●
●
●
●
●
Web based Management Box type of construction
●
●
●
●
●
Configuration with STEP 7 / TIA 19“ type of construction
●
●
●
●
●
SNMP Rugged, compact housing
●
●
●
●
●
●
●
●
●
●
●
●
●
Ring redundancy incl. RM-functionality Modular design
●
●
●
●
●
Standby redundancy 10 Gigabit Ethernet
●
●
●
●
●
●
●
●
IRT capability Gigabit Ethernet
●
●
●
●
●
●
VLAN (Virtual Local Area Network) PoE (Power over Ethernet)
●
●
●
●
●
●
●
●
●
●
●
●
●
GVRP (Generic VLAN Registaration Protocol) LED diagnosis
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
External supply for integrated switch
Management Protocol)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Configuration Protocol)
●
●
●
Access Control List (IP)
●
●
●
●
●
Access Control List (MAC)
●
●
●
●
●
IEEE 802.1x (Radius)
●
●
●
●
●
Link Aggregation
●
●
●
●
Static Routing
●
●
●
●
RIPv2 (Dynamic Routing)
Siemens IK PI · 2015
●
●
●
●
OSPFv2 (Dynamic Routing)
●
●
●
●
Redundancy Protocol)
2/359
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Overview
SCALANCE X408-2/SCALANCE X414-3
Communication connections
• Integral Gigabit Ethernet twisted pair ports
2 (10/100/1 000 Mbit/s, RJ45 sockets) for interconnecting
the SCALANCE X-400 switches:
- SCALANCE X408-2: 4 Gigabit Ethernet twisted pair ports
- SCALANCE X414-3E: 2 Gigabit Ethernet twisted pair ports
• Integral Fast Ethernet twisted pair ports (10/100 Mbit/s, RJ45
sockets with retaining collars) for node connection
- SCALANCE X408-2: 4 Fast Ethernet twisted pair ports
- SCALANCE X414-3E: 12 Fast Ethernet twisted pair ports
• The Gigabit Ethernet ports can be converted to fiber-optic
connections with optical Gigabit Ethernet media modules
Only for SCALANCE X408-2
• Two universal slots either for optical Fast Ethernet or Gigabit
Ethernet media modules with two ports
Only for SCALANCE X414-3E
The SCALANCE X-400 product range comprises modular • Two slots for optical Fast Ethernet media modules with two
Industrial Ethernet switches expandable with various media ports
modules and, in some cases, with extenders. It supports
10/100/1 000 Mbit technology for various transmission media • One extender interface for expansion by 8 Fast Ethernet ports
(twisted pair, fiber optic) and increased port requirements. The (twisted pair or fiber optic, depending on extender version).
main applications are high-performance plant networks (control In this way, a maximum configuration of two Gigabit Ethernet
level). Thanks to its partly modular design, the X-400 product Ports (electrical or optical) and up to 24 Fast Ethernet ports
line is also designed for future requirements and can be adapted (of which between 2 and 12 can be optical) is possible.
to the relevant task. The maximum installation width including extender is 19".
• Two to four integral Gigabit Ethernet twisted pair interfaces Interfaces:
(10/100/1 000 Mbit/s) for connecting several switches to each • Console port (serial interface) for on-site parameterization/
other; node connection via the Fast Ethernet twisted pair ports diagnostics, for firmware update
(10/100 Mbit/s) integrated into the basic unit
• Slot for C-PLUG swap media for easy device replacement
• SCALANCE X414-3E; (included in scope of supply)
another eight nodes can be connected to the basic unit via
extender modules; • Redundant 24 V DC supply; two feeds are available for
the following extender modules are available: protection against voltage failure
- Extenders with eight Fast Ethernet twisted-pair ports • One floating message output for simple display of faults
- Extenders with four media module slots for up to eight Fast Only for SCALANCE X414-3E
Ethernet fiber optic ports
• Additional out-band Ethernet port for on-site parameterization/
• High-speed media redundancy through integral redundancy diagnostics
manager even for large networks, for both Gigabit Ethernet
and Fast Ethernet • Eight floating inputs for recording digital status information
such as signal contacts of PROFIBUS OLM or door contacts
• For the construction of optical Gigabit Ethernet rings, the and forwarding via SCALANCE X-400 diagnostic paths
integrated Gigabit Ethernet ports can be converted to fiber (LED indicator, log table, trap or Email)
optic via a 2-port Gigabit Ethernet media module (MM).
• By means of pluggable 2-port Fast Ethernet media modules Extensive operating mode and status information is displayed
for multimode or alternatively single-mode fiber-optic cable, via LEDs and selection buttons.
SCALANCE X-400 switches can also be integrated into
100 Mbit/s rings, e.g. with SCALANCE X204-2. In this way,
even remote nodes can be connected optically.
• Remote diagnostics by means of PROFINET diagnostics, CLI,
Web browser, or SNMP
• Seamless integration of automation networks into existing
corporate networks thanks to support for a host of IT
standards: Establishment of virtual networks (VLANs)
• Integration into higher-level enterprise networks thanks to
support for standardized redundancy procedures (Rapid
Spanning Tree Protocol)
• By learning the Multicast sources and targets (IGMP: Internet
Group Management Protocol snooping), SCALANCE X-400
switches can also filter Multicast data traffic and therefore limit
the load in the network.
• Creation of IP subnets and IP router communication by means
of Layer 3 switching (IP routing) on SCALANCE X414-3E
- Static routing
- Dynamic routing OSPF (Open Shortest Path First) and RIPv2
(Routing Information Protocol)
- Redundant routing VRRP (Virtual Router Redundancy
Protocol)
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Benefits ■ Application
SCALANCE X-400 products permit the configuration of switched
networks at the control level, which not only demands high avail-
ability of the network and extensive diagnostic options, but also
a high number of ports, high transfer rate and the support of fiber
• Flexible construction of electrical or optical Industrial
Ethernets;
optic and twisted-pair transmission media. SCALANCE X-400
products are designed with IP20 degree of protection for instal-
2
the network topology, type and number of ports can be lation in control cabinets.
adapted easily to the structure of the plant
SCALANCE X408-2
• High availability of the network thanks to:
- Redundant power supply • Control stations with a low concentration of devices
- Redundant network structures based on fiber-optic or • Star hub in plant bus for applications with low concentration of
twisted pair cables (redundancy manager, standby function, devices
RSTP and VRRP are integrated) • High-speed backbone including high-speed media redun-
- Replacement and extension of media and expansion dancy for process control systems
modules during operation
- Easy device replacement by means of plug-in C-PLUG swap • In the high-speed backbone for coupling Gigabit network
medium topologies
• Reliable communication thanks to very fast reconfiguration of SCALANCE X414-3E
the network in the event of a fault • Control stations with a high concentration of devices
• Simple fiber optic connection technology by means of • Star hub in plant bus for applications with high concentration
SC sockets (Gigabit Ethernet), BFOC sockets (Fast Ethernet) of devices
and prefabricated fiber optic cables
• High-speed backbone including high-speed media redun-
• Twisted pair ports are readily accessible from the front, dancy for process control systems
10/100/1 000 Mbit/s;
ports with sleeve for rugged, industry-compatible station • SCALANCE X414-3E equipped with Layer 3 for IP routing
connection for direct connections up to 100 m in conjunction (static, dynamic, redundant)
with the PROFINET-compatible IE FC RJ45 Plug 180 or
IE FC RJ45 Plug 145 connector ■ Design
• Easy network configuration without runtime calculation also for SCALANCE X-400 media modules (MM)
extremely large networks
• Simple monitoring and diagnosis by means of signaling SCALANCE X-400 switches can be equipped with 2-port media
contact, digital inputs, SNMP, Syslog and e-mail; modules. Media modules are available for both multi-mode and
PROFINET IO diagnostics single-mode optical fibers. They can be added or replaced
during network operation. The operating temperature range is
• Reduced engineering expenditure for PLC/HMI due to -40 to +70 °C. The SCALANCE X414-3E basic unit supports two
integration into the SIMATIC system fault message concept optical Gigabit Ethernet ports and up to four additional optical
SFM Fast Ethernet ports.
• Thanks to the integrated Layer 3 function (IP routing) – static,
dynamic and redundant – of SCALANCE X414-3E, networks On two media-module slots, SCALANCE X408-2 supports as
can be divided into different subnets many as four optical ports which can optionally be equipped
with optical Gigabit Ethernet or Fast Ethernet media modules.
• Investment protection for existing networks due to
- Effortless connection of existing 10 bit/s data terminals or The following media modules are available:
network segments to Fast Ethernet networks with 100 Mbit/s • MM491-2;
- Increase in performance through load decoupling and data two fiber optic ports (BFOC sockets) 100 Mbit/s for distances
transfer rates of 100 Mbit/s and 1 000 Mbit/s up to 5 km with multi-mode fiber-optic conductors
- Easy integration into existing network management infra- • MM491-2LD;
structures by means of SNMP two fiber optic ports (BFOC sockets) 100 Mbit/s for distances
• Support of VLAN permits integration into Enterprise Security up to 26 km with single-mode fiber-optic conductors
Policies • MM491-2LH+;
• Load limiting with use of Multicast protocols (e.g. video trans- two fiber optic ports (SC sockets) 100 Mbit/s for distances
mission) by means of IGMP (Internet Group Management up to 70 km with single-mode fiber-optic conductors
Protocol) snooping or GMRP (GARP Multicast Registration • MM492-2;
Protocol) two fiber optic ports (SC sockets) 1 Gbit/s for distances up to
• Protection of network against overload by setting of port 750 m with multi-mode fiber-optic conductors (when using
thresholds SIMATIC NET FO cable 50/125 µm)
• Operating temperature range • MM492-2LD;
- SCALANCE X414-3E: -40 °C to + 70 °C two fiber optic ports (SC sockets) 1 Gbit/s for distances up to
- SCALANCE X408-2: 0 °C to + 60 °C 10 km with single-mode fiber-optic conductors
• Low-maintenance operation thanks to fanless construction • MM492-2LH; two fiber optic ports (SC sockets) 1 Gbit/s for
distances up to 40 km with single-mode fiber-optic
conductors
• MM492-2LH+; two fiber optic ports (SC sockets) 1 Gbit/s for
distances up to 70 km with single-mode fiber-optic
conductors
• MM492-2ELH; two fiber-optic ports (SC sockets) 1 Gbit/s for
distances up to 120 km with single-mode fiber-optic
conductors
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Design (continued)
Plug-in media modules for Gigabit Ethernet convert the Gigabit
Ethernet twisted pair-ports included in the switch to optical
mode. The Gigabit ports can then be used as either twisted-pair SCALANCE X414-3E SCALANCE X414-3E
TP-Ports
or fiber-optic ports. In the case of the SCALANCE X414-3E basic
Ethernet
Ethernet
2
Gigabit
device, optical media modules for Fast Ethernet each generate
Fast
Fast
two additional ports per slot. 2 3 4 5 6 7 8 9 10 11 2 3 4 5 6 7 8 9 10 11
MM492-2
MM491-2
MM491-2
(For SCALANCE X414-3E only)
An optional extender module with up to eight further Fast
Ethernet ports can be mounted next to the expansion interface Gigabit Fast Ethernet e.g. for use in the optical Gigabit
of the SCALANCE X414-3E. The operating temperature range or or or or ring and with connection of four
MM492-2LH+
remote optical nodes and as
MM492-2LH/
is -40 to +70 °C.
MM492-2LD
MM491-2LD
MM491-2LH
many as 12 electrical nodes
MM492-2
MM491-2
Versions
• EM495-8;
with 8 twisted pair ports (RJ45 sockets with sleeves)
10/100 Mbit/s; this enables the 12 onboard Fast Ethernet
SCALANCE X414-3E Extender SCALANCE X414-3E Extender
twisted pair ports of the SCALANCE X414-3E to be expanded
module module
to a total of 20 ports. EM496-4 EM496-4
• EM496-4;
with a further four media module slots for Fast Ethernet media 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 3 4 5 6 7 8 9 10 11 12 13 14 15
modules for up to 8 optical Fast Ethernet ports
MM491-2LD
MM491-2
MM491-2
MM491-2
MM491-2
The structure of the SCALANCE X-400 product line offers the
following advantages
• Simple user connection via twisted pair Fast Ethernet e.g. for use in the electrical
or Gigabit ring and with connection
• Gigabit Ethernet transfer rate between SCALANCE X-400
MM491-2LD
of ten remote optical nodes and
switches
MM491-2
as many as 12 electrical nodes
• Fiber optic connection via fiber-optic media modules
• Reduced costs for spare parts inventories
Electrical and optical variants are covered by a basic unit and
fiber-optic media modules SCALANCE X414-3E Extender SCALANCE X414-3E Extender
module module
EM495-8 EM495-8
SCALANCE X408-2 Example 1 2 3 4 5 6 7 8 9
MM492-2LH+
MM492-2LH/
2 3 4 5 6 7 8 9 10 11 12 13 2 3 4 5 6 7 8 9 10 11 12 13
MM492-2LD
Fast Ethernet
MM491-2
MM492-2LD
Gigabit or
optionally
MM491-2
G_IK10_XX_10180
connecting two remote optical and as
many as four electrical nodes. ring with single mode for links of up
to 10 km in length, with connection
of two remote optical nodes and as
Example 2 2 3 4 5 6 7 8 many as 20 electrical nodes
MM492-2
Gigabit or Fast
Ethernet Possible applications of the media and extender modules with
SCALANCE X414-3E
or or or or e.g. for use in the optical Gigabit
MM492-2LH+
MM491-2LD
MM491-2LH
MM491-2
G_IK10_XX_10201
or
for the redundant coupling of optical
Gigabit rings via electrical Gigabit routes
and with option of connecting up to
four electrical nodes.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Function
• Increasing the network performance; • Redundant interfacing to company networks;
by filtering the data traffic on the basis of the Ethernet (MAC) SCALANCE X-400 switches support the standardized
address of the data terminals, the local data traffic remains redundancy procedures Spanning Tree Protocol (STP) and
local; only data intended for users of another subnetwork are Rapid Spanning Tree Protocol (RSTP). This enables a
forwarded by the switch.
• Simple network configuration and network expansion;
subnetwork to be connected redundantly to a higher level
corporate network with reduced requirements for the recon- 2
the switch saves the data received at the ports and forwards figuration time (in the order of seconds).
it automatically to the destination address. The limitation of the • Support of virtual networks (VLAN)
network expansion by collision detection (CSMA/CD for structuring Industrial Ethernet networks with a fast growing
procedure) terminates at the port. number of users, a physically existing network can be divided
• Limitation of the error propagation to the affected subnetwork; into several virtual networks.
the SCALANCE X-400 switches only forward data with a valid • Integrated hardware Layer 3 Switching function
checksum (CRC). (IP routing, only SCALANCE X414-3E);
• Integration of existing subnetworks with 10 Mbit/s into Fast IP subnetworks can be created and interconnected, e.g.
Ethernet networks with 100 Mbit/s; automation network with office network, enabling a structuring
at the twisted-pair ports, the SCALANCE X-400 switch of the networks.
automatically recognizes the conductor pairs for transmission • Load limiting with use of Multicast protocols
and reception (autocrossover), the data transfer rate of 10 or (e.g. video transmission);
100 Mbit/s, as well as full-duplex and half-duplex operation through learning the Multicast sources and targets (IGMP
(autonegotiation). snooping), SCALANCE X-400 switches can also filter
• High-performance connection of SCALANCE X-400 switches Multicast data traffic and therefore limit the load in the network.
with 1 Gbit/s; • Time synchronization
SCALANCE X-400 switches have two (X414-3E) or four Diagnostic messages (log table entries, e-mails) are time-
(X408-2) Gigabit Ethernet ports for connecting the switches to stamped. The local time is standardized throughout the
each other. network by means of synchronization with a SICLOCK or
• Integrated redundancy manager for constructing Fast SNTP time transmitter, thereby simplifying the assignment of
Ethernet and Gigabit Ethernet ring topologies with high-speed diagnostic messages to several devices.
media redundancy. • Fast replacement of devices in event of failure, by means of
• High-speed standby redundancy; the C-PLUG switching medium
several network segments such as rings can be inter-
connected redundantly with SCALANCE X-400 by means of
the integrated standby function. Two X-400 switches are
configured in a ring as a master and slave and are
connected via two links to the other ring. In the case of
SCALANCE X408-2 or SCALANCE X-300, a high-performance
redundant coupling at 1 000 Mbit/s is possible.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Function (continued)
Operator Station Operator Stations
S7-300
SCALANCE SCALANCE
X414-3E X408-2
1000 Mbit/s
SCALANCE SCALANCE
X408-2 X408-2
S7-300 S7-300
SCALANCE
Third-party system X408-2
1000 Mbit/s
PC
SCALANCE SCALANCE
X414-3E X414-3E
IPC
HMI
S7-300 S7-300
Optical redundant connection of two optical Gigabit subnets with SCALANCE X408-2 on Layer 2 and Layer 3
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Function (continued)
When configuring the network, it is necessary to observe the
following boundary conditions:
Office network (Rapid Spanning Tree Protocol RSTP)
• Maximum line length between two modules for multi-mode
fiber-optic conductors:
2
Switch Switch
- 3 000 m at 100 Mbit/s
- 750 m at 1 Gbit/s
• Maximum line length between two modules for single-mode
fiber-optic conductors:
Ethernet - 70 km at 100 Mbit/s
- 12 km at 1 Gbit/s
• Maximum length of installation cable:
Switch Switch
- 100 m at 100 Mbit/s with IE FC TP Cable 2 x 2 and
IE FC Plug 180
- Max. 90 m at 1 Gbit/s with IE FC TP cable 4 x 2,
IE FC RJ45 modular outlet and patch cable (10 m)
- 100 m at 1 000 Mbit/s with IE FC TP Cable 4 x 2 and
IE FC Plug 4 x 2
SCALANCE X-400
Commissioning and diagnosis
Setting options on the device itself:
• Redundancy manager RM;
to establish a ring, a SCALANCE X-400 is switched to RM
mode. The Gigabit ports (electrical or – with media module –
Industrial optical) are preferably used as ring ports. When using in
Ethernet 100/1000 Mbit/s
optical rings with 100 Mbit/s, the ring ports can be configured
on one media module or on two media modules.
• Signal mask;
the signal mask is set to the current status of the SCALANCE
X-400 (setpoint) by pushbutton operation. It defines which
G_IK10_XX_10066
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Function (continued)
Network management • Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
The network management provides the following functions:
• Loading of new firmware or the configuration data via the
• Password-protected dial-up for "Administrator" (read and write network by a TFTP server
2 authorization) and "User" (read only)
• Read-out of version and status information
• Saving the configuration data or log table via the network on a
TFTP server
• Setting the signal and standby mask and address information • Only for SCALANCE X414-3E:
• Fixed parameterization of the ports (data rates, half/full Configuration of the IP routing function (static routing,
duplex) dynamic routing, (OSPF, RIP v1/2) and redundant routing
• Setting parameters of the VLANs and multicast services (VRRP))
• Parameterization of the standby connections for a redundant If faults occur in the network, the SCALANCE X-400 switch
ring link can independently send error messages (traps) to a network
• Setting of Rapid Spanning Tree parameters management system or also e-mails to a predefined network
administrator.
• Parameterization of user administration of SNMP V1, V2c, V3:
• Output of statistics information Remote monitoring (RMON) provides the following functions:
The SCALANCE XM-400 switch can collect statistics information
according to the RMON groups 1 through 4. These include,
for example, fault statistics that are kept for each port. This infor-
mation can be read out through Web-based management in the
statistics sub-area.
■ Integration
... ...
SCALANCE SCALANCE
X414-3E X414-3E
S7-200
SCALANCE 1000 Mbit/s
X308-2
Gigabit
server 3rd party system
SCALANCE
X408-2
10/100 Mbit/s
S7-300
S7-400
nprXWXWYWY
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
■ Technical specifications
Article No. 6GK5408-2FD00-2AA2 6GK5414-3FC00-2AA2
Product-type designation SCALANCE X408-2 SCALANCE X414-3E
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s 2
Transfer rate 2 100 Mbit/s 100 Mbit/s
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 12 26
connections for network components
or terminal equipment maximum
Number of electrical connections 1 1
for operator console
Design of electrical connection RS232 port RS232 port
for operator console
Number of electrical connections
• for network components 8 14
and terminal equipment
• for network components - 8
and terminal equipment with
extender modules
• for signaling contact 1 1
• for media module 2 3
• for power supply 1 1
• for redundant power supply 1 1
Design of electrical connection
• for network components RJ45 port (4 x 1GE, 4 x FE) RJ45 port (2 x 1GE, 12 x FE)
and terminal equipment
• for network components - RJ45 port via EM495-8
and terminal equipment with
extender modules
• for signaling contact 4-pole terminal block 4-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 4 4
• at 1 000 Mbit/s 4 2
• with extender modules - 8
Design of optical interface
for optical waveguide
• at 100 Mbit/s BFOC or SC ports via media modules MM491-2, BFOC or SC ports via media modules MM491-2,
MM491-2LD, MM491-2LH+ MM491-2LD, MM491-2LH+
• at 1 000 Mbit/s SC ports via media modules MM492-2, MM492-2LD, SC ports via media modules MM492-2, MM492-2LD,
MM492-2LH, MM492-2LH+ MM492-2LH, MM492-2LH+
• with extender modules - BFOC or SC ports via media modules MM491-2,
MM491-2LD, MM491-2LH+, MM492-2, MM492-2LD,
MM492-2LH, MM492-2LH+
Number of extender expansion - 1
interfaces
Design of the extender extension - EM495-8 or EM496-4
interface
Design of the removable storage Yes Yes
C-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A
contacts at DC maximum
Number of digital inputs - 2
Number of electrical connections - 2
for digital input signals
Design of electrical connection - 5-pole terminal block
for digital input signals
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
2 Product function
• Ring redundancy Yes Yes
• Redundancy manager Yes Yes
• Standby redundancy Yes Yes
• High Speed Redundancy Protocol Yes Yes
(HRP)
• Media Redundancy Protocol (MRP) Yes Yes
• Redundancy procedure STP Yes Yes
• RSTP redundancy protocol Yes Yes
• Redundancy procedure MSTP Yes No
• Passive listening Yes Yes
Protocol is supported
• STP/RSTP Yes Yes
• STP Yes Yes
• RSTP Yes Yes
• RSTP big network support Yes Yes
• LACP Yes Yes
Product functions Security
Product function
• ACL - MAC-based Yes Yes
• ACL - port/MAC-based Yes Yes
• IEEE 802.1x (radius) Yes Yes
• Broadcast/Multicast/Unicast Limiter Yes Yes
• broadcast blocking Yes Yes
Protocol is supported SSH Yes Yes
Product functions Time
Product function SICLOCK support Yes Yes
Protocol is supported
• NTP No No
• SNTP Yes Yes
Standards, specifications,
approvals
Standard
• for EMC from FM FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, FM3611: Class 1, Division 2, Group A, B, C, D / T4 A,
Class 1, Zone 2, Group IIC, T4 Class 1, Zone 2, Group IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, EN 60079-0: 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4,
KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1-03 UL 60950-1, CSA C22.2 No. 60950-1-03
• for hazardous area of CSA and UL UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / UL 1604 and UL 2279-15 (Hazardous Location), Class 1 /
Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 /
Group IIC / T4 Group IIC / T4
• for emitted interference EN 61000-6-4:2001 (Class A) EN 61000-6-4:2001 (Class A)
• for interference immunity EN 61000-6-2:2001 EN 61000-6-2:2001
Verification of suitability EN 61000-6-2:2001, EN 61000-6-4:2001 EN 61000-6-2:2001, EN 61000-6-4:2001
• CE mark Yes Yes
• C-Tick Yes Yes
• KC approval Yes Yes
Marine classification association
• American Bureau of Shipping Eu- Yes Yes
rope Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes
• Det Norske Veritas (DNV) Yes Yes
• Germanische Lloyd (GL) Yes Yes
• Lloyds Register of Shipping (LRS) Yes Yes
• Nippon Kaiji Kyokai (NK) Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
2 Verification of suitability
• CE mark
EN 61000-6-2:2001,
EN 61000-6-4:2001
Yes
EN 61000-6-2:2001,
EN 61000-6-4:2001
Yes
EN 61000-6-2:2001,
EN 61000-6-4:2001
Yes
EN 61000-6-2:2001,
EN 61000-6-4:2001
Yes
EN 61000-6-2:2001,
EN 61000-6-4:2001
-
• C-Tick Yes Yes Yes Yes -
• KC approval Yes Yes Yes Yes Yes
• Railway application in accordance - - - - -
with EN 50155
• Railway application in accordance - - - - -
with EN 50124-1
• IEC 61850-3 - - - - -
Marine classification association
• American Bureau Yes Yes Yes Yes Yes
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) Yes Yes Yes Yes Yes
• Det Norske Veritas (DNV) Yes Yes Yes Yes Yes
• Germanische Lloyd (GL) Yes Yes Yes Yes Yes
• Lloyds Register of Shipping (LRS) Yes Yes Yes Yes Yes
• Nippon Kaiji Kyokai (NK) Yes Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
2 Number of electrical/optical
connections for network components
8 8
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
2
for setting up electrical and/or
optical Industrial Ethernet networks; EM495-8; 6GK5495-8BA00-8AA2
integrated redundancy manager, with 8 x 10/100 Mbit/s
IT functions (RSTP, VLAN, ...), TP ports
PROFINET IO device, EM496-4; 6GK5496-4MA00-8AA2
network management via SNMP with 4 slots for 100 Mbit/s
and web server; media modules MM
incl. operating instructions,
Industrial Ethernet network manual Accessories
and configuration software
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
on CD-ROM;
(Type A)
C-PLUG included in the
scope of delivery 4-core, shielded TP installation
• SCALANCE X408-2; 6GK5408-2FD00-2AA2 cable for connection to
4 x 10/100/1 000 Mbit/s and IE FC Outlet RJ45/IE FC RJ45 Plug;
4 x 10/100 Mbit/s RJ45 ports; PROFINET-compatible;
2 x Gigabit/Fast Ethernet media with UL approval;
module slots sold by the meter;
• SCALANCE X414-3E; 6GK5414-3FC00-2AA2 max. length 1 000 m,
8 x 10/100/1 000 Mbit/s, of which minimum order quantity 20 m
8 x RJ45/SFP combo ports; IE FC TP Standard Cable GP 4 x 2 6XV1870-2E
8 x 1 000 Mbit/s can be maximally
used in the basic device 8-core, shielded TP installation
24 x 1 000 Mbit/s maximum overall cable for connection to
configuration by using port IE FC RJ45 modular outlet
extenders for universal application;
with UL approval;
MM491/MM492 media modules sold by the meter;
Media modules with 2 ports; max length 1 000 m,
1 Gbit/s minimum order 20 m
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Overview
Product versions – basic devices
Basic devices with eight to 16 integrated Gigabit Ethernet
twisted pair interfaces (10/100/1 000 Mbit/s)
XM416-4C 2
• 16 ports available in total, of which
- up to 16 x 10/100/1 000 Mbit/s are RJ45 ports with retaining
collars
- up to 4 x SFP slots (combo ports), 100 or 1 000 Mbit/s
• A port extender with 8 ports can be connected to implement
a maximum of 24 ports in one switch
XM408-8C
• 8 ports available in total, of which
- up to 8 x 10/100/1 000 Mbit/s are RJ45 ports with retaining
collars
- up to 8 x SFP slots (combo ports), 100 or 1 000 Mbit/s
• Two port extenders with 8 ports each can be connected to
implement a maximum of 24 ports in one switch
The new SCALANCE XM-400 product range comprises modular
Industrial Ethernet switches, expandable by various port XM408-4C
extenders and plug-in transceivers for a maximum configuration • 8 ports available in total, of which
with up to 24 ports. It supports 10/100/1 000 Mbit technology for - up to 8 x 10/100/1 000 Mbit/s are RJ45 ports with retaining
various transmission media (twisted pair, fiber optic) and collars
increased port requirements. The main applications are high- - up to 4 x pluggable slots (combo ports) for SC connection
performance plant networks (control level). Thanks to the method (1 000 Mbit/s) or BFOC connection method
flexible, modular design, the XM-400 product line is also (100 Mbit/s)
designed for future requirements and can be adapted to the • Two port extenders with 8 ports each can be connected to
relevant task. implement a maximum of 24 ports in one switch
The new XM-400 range replaces the previous X-400 range
(X414-3E and X408-2).
• Combo ports for the flexible use of interfaces: A combo port
consists of an electric port and an SFP slot. Only one of the
two ports can ever be active. If an SFP plug-in transceiver is
inserted, the electric port is deactivated
• Fast mobile diagnosis with smartphone/tablet thanks to WLAN
and NFC: Fast access to the web-based management of the
SCALANCE XM-400 via mobile websites. The function can be
started using existing WLAN and NFC (Near Field Communi-
cation)
• High-speed media redundancy through integral redundancy
manager even for large networks, for both Gigabit Ethernet
and Fast Ethernet
• Remote diagnostics by means of PROFINET diagnostics, CLI,
Web browser, or SNMP
• Integration into the TIA Portal including up/downloading of the
configuration
• Seamless integration of automation networks into existing
corporate networks thanks to support for a host of IT
standards: Establishment of virtual networks (VLANs)
• Integration into higher-level enterprise networks thanks to
support for standardized redundancy procedures
(Rapid Spanning Tree Protocol, Link Aggregation)
• By learning the multicast sources and destinations
(Internet Group Management Protocol (IGMP) Snooping),
SCALANCE XM-400 switches can also filter multicast data
traffic and thus limit the load on the network.
• Optional activation of the Layer 3 functions for IPv4 (IPv6
available soon) in connection with the KEY-PLUG XM-400.
For a detailed description, see "Accessories for Layer 3
switches/routers"
• Creation of IP subnets and IP router communication by means
of Layer 3 switching (IP routing)
- Static routing
- Dynamic routing OSPF (Open Shortest Path First) and RIPv2
(Routing Information Protocol)
- Redundant routing VRRP (Virtual Router Redundancy
Protocol)
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Benefits
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Function
• Fast redundancy in the ring; Additional function through Layer 3 KEY PLUG
A redundant network structure is created by inter- • Layer 3 switching support
connecting the ends of an optical line to form a ring. - Static routing
The SCALANCE XM-400 switches have an integral redun- - Dynamic routing
2 dancy manager (RM) which monitors the function of the
network continuously. It recognizes the failure of a trans-
- Router redundancy
The integrated dynamic routing protocols OSPF (Open
mission path or the failure of a SCALANCE XM-400 switch in Shortest Path First) and RIPv2 (Routing Information Protocol)
the ring and then activates the substitute path. In rings govern the communication to other IP routers in the network.
with SCALANCE X-200 or OSM/ESM, it is possible to
integrate XM-400 switches at 100 Mbit/s. In rings with • Redundant Layer-3 switching (routing) is achieved with the
SCALANCE X-300 and SCALANCE XR-500, it is possible to integrated VRRP function (Virtual Router Redundancy
integrate XM-400 switches with Gigabit. Protocol).
• Fast standby redundancy; • IPv6 support (available soon), support of dual-stack routing
The integrated standby function permits a reliable intercon- (IPv4 / IPv6)
nection of several rings. Two transmission links are used to Integrated security
connect two XM-400 switches of a ring to the other ring
• Port security
• Time synchronization;
diagnostic messages (log table entries, e-mails) are time- • Access Control to Agent
stamped. The local time is standardized throughout the • Authentication 802.1X
network by means of time synchronization with a time server, • SSH
thereby simplifying the assignment of diagnostic messages of
several devices. • HTTPS
• Load limiting when using multicast protocols • SNMPv3
(e.g. Voice over IP, Video) • RADIUS
• By learning the multicast receivers, XM-400 switches can also Network topology and network configuration
filter multicast data traffic and thus limit the load in the network.
• Redundant interfacing to company networks; The network topology can easily be adapted to the structure of
XM-400 switches support the standardized redundancy the plant with SCALANCE XM-400 Industrial Ethernet switches.
procedures Spanning Tree Protocol (STP) and Rapid The following network structures and combinations of structures
Spanning Tree Protocol (RSTP). This enables a subnetwork to can be implemented:
be connected redundantly to a higher level corporate network • Gigabit and Fast Ethernet rings with fast media redundancy:
with reduced requirements for the reconfiguration time (in the To protect against the failure of a transmission link or a switch,
order of seconds). up to 50 linearly cascaded switches can be interconnected
• Support for virtual networks (VLAN); to form a ring. On the failure of a transmission link or of a
For structuring Industrial Ethernet networks with a fast growing switch in the ring, the transmission path is reconfigured within
number of users, a physically existing network can be divided 300 milliseconds.
into several virtual subnets, e.g. to divide the network into • Several rings can be redundantly linked through the standby
logical areas. In this way, very large Ethernet networks can be function.
subdivided into smaller subnets with their own IP address • In addition, SCALANCE XM-400 supports redundant
space. connection of the ring structure to the corporate network with
• Support for Quality of Service (QoS) through IP Type of Service a rapid spanning tree.
(ToS) and prioritizing according to 802.1Q • Star topology with SCALANCE XM-400 switches:
• Link Aggregation (IEEE 802.3ad) for parallel use of ports to The switch represents a neutral star point that can inter-
increase the transmission rate and fail-safety. connect up to 24 nodes or subnets electrically or optically
• Support for port prioritization When configuring the network, it is necessary to observe the
• Support for bandwidth limiting (Broadcast Limiter, Multicast following boundary conditions:
Limiter, Unicast Limiter) • Maximum line length between two modules for multi-mode
• Flow control fiber-optic conductors:
- 5 000 m at 100 Mbit/s
• Simple device replacement; - 750 m at 1 Gbit/s
All settings are automatically backed up on the C-PLUG
plug-in swap medium (included in scope of delivery). If a • Maximum line length between two modules for single-mode
switch of the SCALANCE XM-400 series has to be replaced, fiber-optic conductors:
then these settings are simply transferred to the replacement - 200 km at 100 Mbit/s
device by plugging in the C-PLUG. - 120 km at 1 Gbit/s
• Maximum length of installation cable:
- 100 m at 100 Mbit/s with IE FC TP Cable 2 x 2 and
IE FC Plug 180
- Max. 90 m at 1 Gbit/s with IE FC TP cable 4 x 2,
IE FC RJ45 modular outlet and patch cable (10 m)
- 100 m at 1 000 Mbit/s with IE FC TP Cable 4 x 2 and
IE FC Plug 4 x 2
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Function (continued)
Commissioning and diagnosis
• Signal mask;
The signal mask is set to the current status of the
SCALANCE XM-400 (setpoint state) by pushbutton operation.
The signal mask defines which ports and which power
supplies are to be monitored. The signal contact only reports
2
an error when a monitored port or a monitored feeder fails
(deviation of setpoint/actual status).
• Using a serial interface (RJ11), a PC or a programming device
can be connected directly; operation is carried out using
commands (Command Line Interface - CLI)
• IP address;
the IP address is assigned via DHCP (Dynamic Host Configu-
ration Protocol). If there is no corresponding server in the
network, the IP address can be assigned using an enclosed
software tool or via the serial console interface (CLI).
• The following status information is displayed by LEDs on site:
- Port status
- Port mode (10/100/1 000 Mbit/s, full/half-duplex)
- Status of the two voltage feeders
- Signal contact status
- Signal mask (setpoint status)
- RM mode
- Standby mode
• The status of the signal contact is routed externally by means
of floating relay contacts. This enables, for example, the
module to be monitored via an input module from a controller.
• Redundancy manager RM;
To establish a ring, a SCALANCE XM-400 is switched to the
RM mode. The non-ring ports of the RM can be used freely for
the connection of data terminals and networks. If the redun-
dancy procedure MRP standardized by PROFINET is used,
the RM is adjusted automatically.
• Monitoring via the Industrial Ethernet network;
the following possibilities are available:
- via standard browser (Web-based management):
Selection of SCALANCE XM-400 switches via the network
from a PC with browser
- via the browser of a mobile device (Smartphone, Tablet)
- Reading out the address of the mobile website of the XM-400
by means of NFC:
- mobile terminal starts browser with this address
- powerful diagnosis by means of an existing WLAN
- via SNMP V1, V2c, V3:
Secure integration of SCALANCE X-400 switches via the
network into a network management system, e.g. SINEMA
Server
- via PROFINET IO diagnostics:
Standard diagnostic alarms can be configured in an easy,
familiar manner in STEP 7 and processed in SIMATIC.
The engineering outlay is drastically reduced for the PLC
and HMI through complete integration in the SIMATIC
system error message concept SFM.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Function (continued)
Network management
The network management provides the following functions:
• Password-protected dial-up for "Administrator" (read and write
2 authorization) and "User" (read only)
• Access protection by means of access control list
• Encrypted HTTPS access
• Read-out of version and status information
• Setting the signal and standby mask and address information
• Fixed parameterization of the ports (data rates, half/full
duplex)
• Setting parameters of the VLANs and multicast services
• Parameterization of the standby connections for a redundant
ring link
• Setting of Rapid Spanning Tree parameters
• Defining a maximum load per port for load limiting
(port thresholds)
• Output of statistics information
• Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
• Loading of new firmware or the configuration data via the
network by a TFTP server
• Saving the configuration data or log table via the network on a
TFTP server
• Configuration of the IP routing function after activation with
KEY-PLUG (static routing, dynamic routing (OSPF, RIP v1/2),
and redundant routing (VRRP))
If faults occur in the network, the SCALANCE XM-400 switch
can independently send error messages (traps) to a network
management system (e.g. SINEMA Server) or also e-mails to a
predefined network administrator.
Remote monitoring (RMON) provides the following functions:
The SCALANCE XM-400 switch can collect statistics information
according to the RMON groups 1 through 4. These include,
for example, fault statistics that are kept for each port. This infor-
mation can be read out through Web-based management in the
statistics sub-area.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Integration
Backbone
Industrial Ethernet /
2
SCALANCE XM416-4C with PROFINET (Twisted Pair)
Port Extender PE408 Industrial Ethernet /
PROFINET (Fiber Optic)
VRRP
VLAN 1, 2, 3
G_IK10_XX_10212
HMI HMI HMI HMI HMI
VLAN 1 VLAN 2 VLAN 1 VLAN 3 VLAN 3
Network structuring through the routing of virtual LANs (a VLAN corresponds to an IP subnetwork)
Factory Backbone
(10 Gbit/s)
SCALANCE XR552-12M SCALANCE XR552-12M
Ethernet
Subnet 1
Building Backbone
(1000 Mbit/s) SCALANCE XM-400 with
Port Extender PE408
Industrial Ethernet
Control Level
(100 - 1000 Mbit/s)
Subnetworks with SCALANCE X308-12M and SCALANCE XM-400 for increasing network availability
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Integration (continued)
Operator Station (OS) OS SIMATIC IT SIMATIC Batch OS Engineering Station (ES)
2
SCALANCE Terminal bus SCALANCE
XM 408-8C XM 408-8C
1000 Mbit/s
IPC
SCALANCE
X310
OS Server OS Server
Industrial Ethernet (redundant) 1000 Mbit/s (redundant)
(electrical)
SCALANCE SCALANCE
XM 408-8C XM 408-8C
Industrial Ethernet Plant Bus
(optical)
SCALANCE
IPC 1000 Mbit/s
XM 416-4C
SCALANCE
X308-2
SCALANCE XM 416-4C
SCALANCE Human machine
XM 416-4C interface
G_IK10_XX_10183
ET 200M ET 200M
Use of the SCALANCE XM-400 switches in a process control system, e.g. PCS 7
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
■ Technical specifications
Article No. 6GK5416-4GS00-2AM2 6GK5408-8GS00-2AM2 6GK5408-4GP00-2AM2
Product-type designation SCALANCE XM416-4C SCALANCE XM408-8C SCALANCE XM408-4C
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
2
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Interfaces
Number of electrical/optical 24 24 24
connections for network components
or terminal equipment maximum
Number of electrical connections 1 1 1
for operator console
Design of electrical connection RJ11 port RJ11 port RJ11 port
for operator console
Number of electrical connections
• for network components 16 8 8
and terminal equipment
• for network components 8 16 16
and terminal equipment with
extender modules
• for signaling contact 1 1 1
• for media module - - -
• for power supply 1 1 1
• for redundant power supply 1 1 1
Design of electrical connection
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
• for network components RJ45 port RJ45 port RJ45 port
and terminal equipment
with extender modules
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s 4 8 4
• at 1 000 Mbit/s 4 8 4
• with extender modules 8 16 16
Design of optical interface
for optical waveguide
• at 100 Mbit/s SFP slot SFP slot SFP slot
• at 1 000 Mbit/s SFP slot SFP slot SFP slot
• with extender modules SFP slot SFP slot SFP slot
Number of extender expansion 2 2 2
interfaces
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC
Supply voltage external 24 V 24 V 24 V
• minimum 19.2 V 19.2 V 19.2 V
• maximum 28.8 V 28.8 V 28.8 V
Product component fusing Yes Yes Yes
at power supply input
Type of fusing at input F 15 A / 125 V F 15 A / 125 V F 15 A / 125 V
for supply voltage
Consumed current maximum 2A 2A 2A
Active power loss
• at 24 V for DC 48 W 48 W 48 W
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
2 Ambient temperature
• during operating -40 … +70 °C -40 … +70 °C -40 … +70 °C
• during storage -40 … +85 °C -40 … +85 °C -40 … +85 °C
• during transport -40 … +85 °C -40 … +85 °C -40 … +85 °C
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Protection class IP IP20 IP20 IP20
Design, dimensions and weight
Design SIMATIC S7-1500 device design SIMATIC S7-1500 device design SIMATIC S7-1500 device design
Width 140 mm 140 mm 140 mm
Height 147 mm 147 mm 147 mm
Depth 125 mm 125 mm 125 mm
Net weight 1.25 kg 1.15 kg 1.15 kg
Mounting type
• 35 mm DIN rail mounting Yes Yes Yes
• wall mounting No No No
• S7-300 rail mounting Yes Yes Yes
• S7-1500 rail mounting Yes Yes Yes
Product properties, functions,
components general
Cascading in the case of a
redundant ring at reconfiguration time
of < 0.3 s
Cascading in cases Any Any Any
of star structuring (depending only on signal (depending only on signal (depending only on signal
propagation time) propagation time) propagation time)
Product functions management,
configuration
Product function
• CLI Yes Yes Yes
• web-based management Yes Yes Yes
• MIB support Yes Yes Yes
• TRAPs via email Yes Yes Yes
• Configuration with STEP 7 Yes Yes Yes
• RMON Yes Yes Yes
• Port mirroring Yes Yes Yes
• CoS Yes Yes Yes
• PROFINET IO diagnosis Yes Yes Yes
• switch-managed Yes Yes Yes
Protocol is supported
• Telnet Yes Yes Yes
• HTTP Yes Yes Yes
• HTTPS Yes Yes Yes
• TFTP Yes Yes Yes
• FTP Yes Yes Yes
• BOOTP Yes Yes Yes
• SNMP v1 Yes Yes Yes
• SNMP v2 Yes Yes Yes
• SNMP v3 Yes Yes Yes
• IGMP (snooping/querier) Yes Yes Yes
• GMRP Yes Yes Yes
• DCP Yes Yes Yes
• LLDP Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes
• I&M1 - higher level designation/ Yes Yes Yes
location designation
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
2 Protocol is supported
• Telnet Yes Yes Yes
• HTTP Yes Yes Yes
• HTTPS Yes Yes Yes
• TFTP Yes Yes Yes
• FTP Yes Yes Yes
• BOOTP Yes Yes Yes
• SNMP v1 Yes Yes Yes
• SNMP v2 Yes Yes Yes
• SNMP v3 Yes Yes Yes
• IGMP (snooping/querier) Yes Yes Yes
• GMRP Yes Yes Yes
• DCP Yes Yes Yes
• LLDP Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes
• I&M1 - higher level Yes Yes Yes
designation/location designation
Product functions Diagnosis
Product function
• Port diagnostics Yes Yes Yes
• Statistics packet size Yes Yes Yes
• Statistics packet type Yes Yes Yes
• Error statistics Yes Yes Yes
• SysLog Yes Yes Yes
Product functions VLAN
Product function
• VLAN - port based Yes Yes Yes
• VLAN dynamic Yes Yes Yes
Number of VLANs maximum 255 255 255
Number of VLANs - dynamic maxi- 255 255 255
mum
Protocol is supported GVRP Yes Yes Yes
Product functions DHCP
Product function
• DHCP client Yes Yes Yes
• DHCP Option 82 Yes Yes Yes
• DHCP Option 66 Yes Yes Yes
• DHCP Option 67 Yes Yes Yes
Product functions Routing
Service Routing Note IP-Routing integrated IP-Routing integrated IP-Routing integrated
Product function
• static IP routing Yes Yes Yes
• dynamic IP routing Yes Yes Yes
Protocol is supported
• RIPv2 Yes Yes Yes
• OSPFv2 Yes Yes Yes
• VRRP Yes Yes Yes
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
2
• PE408; 6GK5408-0GA00-8AP2 the device functions with IP routing
with 8 x 10/100/1 000 Mbit/s (Layer 3), for integration of
TP ports configuration data and for easy
• PE400-8SFP; 6GK5400-8AS00-8AP2 replacement of SCALANCE XM-400
with 8 slots for 100/1 000 Mbit/s in the event of a fault
SFP plug-in transceivers
• PE408PoE; 6GK5408-0PA00-8AP2 C-PLUG 6GK1900-0AB00
with 8 x 10/100/1 000 Mbit/s Swap medium for simple
TP ports replacement of devices in the
Power over Ethernet according event of a fault;
• to 802.3at Type 1 and 2 for storing configuration or
application data;
Plug-in transceiver can be used for SIMATIC NET
products with C-PLUG slot
ST and SC plug-in transceivers for
XM-400 basic device XM408-4C Power supplies
STP991-1 6GK5991-1AB00-8AA0 SIMATIC PM 1507 24 V
100 Mbit/s, ST/BFOC connection, stabilized power supply for
multi-mode FOC up to 5 km SIMATIC S7-1500
STP991-1LD 6GK5991-1AC00-8AA0 • Power supply S7-1500 PM1507 6EP1332-4BA00
100 Mbit/s, ST/BFOC connection, SIMATIC PM 1507 24 V/3 A
single-mode FOC up to 26 km stabilized power supply for
SIMATIC S7-1500
SCP992-1 6GK5992-1AJ00-8AA0 Input: 120/230 V AC
1 000 Mbit/s, SC connection, Output: 24 V DC/3 A
multi-mode FOC up to 750 m • Power supply S7-1500 PM1507 6EP1333-4BA00
SCP992-1LD 6GK5992-1AK00-8AA0 SIMATIC PM 1507 24 V/8 A
1 000 Mbit/s, SC connection, stabilized power supply for
single-mode FOC up to 10 km SIMATIC S7-1500
• Input: 120/230 V AC
SFP plug-in transceivers see "Plug-in transceivers for Output: 24 V DC/8 A
for XM-400 SCALANCE XR-500"/
"Media modules for modular Miscellaneous accessories
SCALANCE X-500 managed" 4-pole spring-loaded 6GK5980-1DB10-0AA5
terminal block
Spring-type 4-pole terminal
for power supply (24 V DC) for
SCALANCE X/W/S/M;
1 pack = 5 items
2-pole spring-loaded 6GK5980-0BB10-0AA5
terminal block
Spring-type 2-pole terminal
for signaling contact (24 V DC) for
SCALANCE X/W/S/M;
1 pack = 5 items
Screw for fixing to S7-1500 and 6GK5980-4AA00-0AA5
S7-300 rails
Mounting screw
for SCALANCE X/W/S/M;
1 pack = 5 items
Connection cable (RJ11/RS232) 6GK5980-3BB00-0AA5
pre-assembled serial cable
with RJ11 and RS323 connector,
length: 5 m; 1 item per pack
■ More information
Selection tools:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
■ Overview
device
Type of
● applies
XR528-6M
XR528-6M
XR524-8C
XR524-8C
XR552-12M/
XR552-12M/
Security Integrated (Firewall/VPN) Connection to S7 backplane bus
●
●
PROFINET diagnosis Format module S7
Software
●
●
Hardware
●
●
Command Line Interface / Telnet Flat type of construction
●
●
Web based Management Box type of construction
●
●
●
●
●
●
SNMP Rugged, compact housing
●
●
●
●
Ring redundancy incl. RM-functionality Modular design
●
●
●
Standby redundancy 10 Gigabit Ethernet
●
●
IRT capability Gigabit Ethernet
●
●
●
●
VLAN (Virtual Local Area Network) PoE (Power over Ethernet)
●
●
●
GVRP (Generic VLAN Registaration Protocol) ● LED diagnosis
●
●
●
●
●
●
●
●
●
●
●
External supply
Management Protocol)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Configuration Protocol)
●
●
Access Control List (MAC)
●
●
IEEE 802.1x (Radius)
●
●
Link Aggregation
●
●
Static Routing
●
●
RIPv2 (Dynamic Routing)
Siemens IK PI · 2015
●
●
OSPFv2 (Dynamic Routing)
● VRRP, Router Redundancy (Virtual Router
●
Redundancy Protocol)
2/395
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE X-500 managed
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
Product versions
■ Overview
SCALANCE XR552-12M
• LEDs and ports on the front
• Alternatively: LEDs on the front and ports at the rear
2
• Connection of power supply unit at rear or above/below the
switch
• Four SFP+ slots for equipping with 10 Gigabit Ethernet SFP+
plug-in transceivers or Gigabit SFP plug-in transceivers
• 12x 4-port media module slots
• Available with integrated IP routing functions or for the
optional extension of the IP routing functions by means of
KEY-PLUG
SCALANCE XR528-6M
• LEDs and ports on the front
• Alternatively: LEDs on the front and ports at the rear
• Connection of power supply unit at rear or above/below the
switch
• Four SFP+ slots for equipping with 10 Gigabit Ethernet SFP+
The Layer 3-enabled SCALANCE XR-500 Industrial Ethernet plug-in transceivers or Gigabit SFP plug-in transceivers
switches are fully modular, high-performance, industry-standard
• 6x 4-port media module slots
switches for the construction of electrical and optical line, ring
and star topologies with data transfer rates of up to 10 Gbit/s, • Available with integrated IP routing functions or for the
designed for installation in 19" control cabinets. optional extension of the IP routing functions by means of
KEY-PLUG
• Four optical interfaces (10 Gbit/s) and up to 48 electrical
and/or optical interfaces (10/100/1 000 Mbit/s), of which up to SCALANCE XR524-8C
12 electrical PoE interfaces; • Eight combo-ports for optional use of optical or electrical inter-
up to twelve electrical and/or optical 4-port media modules faces with 10/100/1 000 Mbit/s optically or electrically via SFP
can be plugged into the basic unit at any point. plug-in transceiver
• Fast media redundancy due to the integrated redundancy • 16 electrical ports operating at 10/100/1 000 Mbit/s
manager:
Redundant connection of rings by means of high-speed • In total, 24 ports can be used
media redundancy is also possible with SCALANCE XR-500. • Power supply versions 24 V and 230 V (integrated)
• Seamless integration of automation networks into existing • Available with integrated IP routing functions or for the
corporate networks thanks to support for a host of IT standard optional extension of the IP routing functions by means of
functions (VLANs, IGMP-Snooping/Querier, STP/RSTP/MSTP, KEY-PLUG
Link Aggregation, Quality of Service, 802.1X and optional
static routing, RIP, OSPF, VRRP for IPv4 and IPv6) ■ Benefits
• PROFINET diagnostics, Web browser, CLI and SNMP
• Redundant integration into higher-level networks through
support for standardized redundancy procedures (Multiple
Spanning Tree Protocol, Spanning Tree Protocol, Rapid
Reconfiguration Spanning Tree Protocol, Media Redundancy • Unlimited flexibility during network expansions (e.g. more
Protocol) and standardized IP routing protocols or procedures terminals, higher data transfer rates, PoE ports) or conversion
(Routing Information Protocol, Open Shortest Path First, Virtual (e.g. switching from copper to fiber-optic cable) and reduction
Router Redundancy Protocol) of the storage costs due to the fully modular construction
• KEY-PLUG as the swap medium with which Layer 3 routing using SFPplus/SFP and media modules
functions can be enabled. • Retrofitting the Layer 3 switching functions (IP routing) by
- For the automatic backup of configuration data. If a fault means of a license on KEY-PLUG without replacing the
occurs, it allows fast and simple device replacement of existing hardware
SCALANCE X-500 components without a Field PG (contains
the function of the C-PLUG) • Changing the media modules during operation
- Can be used in all Layer 2 variants of the SCALANCE XR552 • High availability of the network thanks to
and XR528 - redundant power supply
- For a detailed description, see "SCALANCE Accessories for - redundant network structures based on FOC or Twisted Pair
Layer 3 Switches / Routers" (redundancy manager, standby function and STP/RSTP/
MSTP integrated)
- easy device replacement by means of plug-in C-PLUG/
KEY-PLUG swap medium
- very fast reconfiguration of the network in event of a fault
• Thanks to the support of the Dual Stack Routing function, IPv4
networks and IPv6 networks can overlap and be operated in
parallel
• High flexibility thanks to variable mounting options of the
power supply unit and device variants with ports on either the
front or rear of the device.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
The SCALANCE XR-500 switches are available with the following
■ Application port types:
The SCALANCE XR-500 switches are ideal for use in industrial • Four SFP+ slots for optical SFP+ or SFP plug-in transceivers
networks and for integrating the industrial network into an exist- (multimode and singlemode connections)
ing corporate network. From the control level to the management - The SFP+ plug-in transceivers support 10 Gbps
level, the switch handles the networking of plant sections as well - The SFP plug-in transceivers support 1 000 Mbps
as distributed field devices and ensures high plant availability
with extensive diagnostics options and high transmission
• Up to 12 slots for electrical 4-port media modules and 2
electrical PoE 4-port media modules or optical 4-port media
speeds. Thanks to the scalability of the basic unit and the option- modules for multimode or singlemode connections; the
ally available Layer 3 switching function, the network can be optical media modules are available in various connection
established specially for the relevant application, or adapted technologies
and expanded at any time. - The RJ45 sockets are also available in industry-standard
The SCALANCE XR-500 switches are suitable for establishing design with additional retaining collars for connection of the
electrical and optical Industrial Ethernet line, star or ring Industrial Ethernet FC RJ45 Plug 180
topologies with four integral SFP+ slots that can be optionally - All electrical Ethernet interfaces support
equipped with SFP+ plug-in transceivers (10 Gbit/s) or SFP 10/100/1 000 Mbps,
plug-in transceivers (1 000 Mbit/s), and up to 12 media module all optical Ethernet interfaces support 100 or 1 000 Mbps
slots that can be optionally equipped with electrical and/or opti-
cal 4-port media modules. Thanks to data transfer rates of up to
10 Gbit/s, the switches can be used as an Industrial Ethernet
backbone switch and as a hub in the plant bus (redundant
connection possible).
The use of media modules or SFP+/SFP enables the following:
• Extension of networks by subsequent insertion of additional
media modules in unused media module slots
• Changing of cabling technology, e.g. conversion from copper XR552-12M XR552-12M
to fiber-optic cables, or from multimode to singlemode FOC with basic power supply, with redundant power supply,
• Changing of the data transfer rate, e.g. from 1 000 Mbit/s to bottom mounting bottom mounting
10 Gbit/s
■ Design
The SCALANCE XR-500 Industrial Ethernet switches with robust
metal enclosure with IP20 degree of protection are optimized for
installation in the 19" control cabinet. The power supply unit
G_IK10_XX_10324
(85 to 264 V AC) for power supply to the SCALANCE XR-500,
which is also optimized for the 19" cabinet , can either be XR552-12M XR552-12M
installed directly at the rear of the SCALANCE XR-500 or con-
with basic power supply, with redundant power supply,
nected using connecting cables (installation of the power supply rear mounting rear mounting
unit in a 19" rack). The data ports of the SCALANCE XR-500 are
located optionally either at the front or rear of the device
(depending on the device variant). Options for mounting a single/redundant power supply unit to
The switches have: SCALANCE XR552-12M
• 4-pole terminal block on the front for connecting the optionally
available power supply unit (85 V to 264 V AC)
• 6-pole connector for assembly of the optionally available
power supply unit (85 V to 264 V AC) on the rear
• 2-pole terminal block for connecting the isolated signaling
contact for simple display of faults
• Row of LEDs for indicating status information (power, link
status, data transfer, power supply, signaling contact)
• SELECT/SET pushbutton for easy setting of the fault signaling
contact on the device
• Slot on the side of the device for the C-PLUG swap medium for
simple device replacement in the event of a fault, or for the
KEY-PLUG for adding IP routing to the device functionality
• Console port (RS 232 serial interface, RJ11 cable to Sub-D (9-
pole) included in scope of delivery) and management port
(Ethernet interface) for on-site parameter assignment/
diagnostics
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
■ Function
• Integrated redundancy manager for constructing ring topol- • Thanks to support for the Dual Stack Routing function, both
ogies with up to 10 Gbps and high-speed media redundancy. IPv4 addressing and IPv6 addressing can be operated in one
By interconnecting the ends of an optical or electrical line network.
to form a ring, reliable communication can be achieved. • Support of virtual networks (VLAN);
2 The redundancy manager (RM) integrated in the
SCALANCE XR-500 switch monitors the function of the
for structuring Industrial Ethernet networks with a fast growing
number of users, a physically existing network can be divided
network. It recognizes the failure of a transmission link or of a into several virtual networks. Port-based, protocol-based and
SCALANCE X switch in the ring and activates the substitute IP-based VLANs are available for selection.
path within a maximum of 200 milliseconds.
• Load limiting when multicast protocols (e.g. video trans-
• Redundant Layer 2 interfacing to company networks; mission) are used;
SCALANCE XR-500 switches support the standardized through learning the multicast receivers (IGMP Snooping,
redundancy procedures Multiple Spanning Tree Protocol IGMP Querier), SCALANCE XR-500 switches can also filter
(MSTP), Rapid Spanning Tree Protocol (RSTP), and Spanning multicast data traffic and therefore limit the load in the network.
Tree Protocol (STP). This enables a subnet to be connected Multicast and broadcast traffic can be limited.
redundantly to a higher-level corporate network with reduced
requirements for the reconfiguration time (in the order of • Time synchronization;
seconds). diagnostic messages (log table entries, e-mails) are time-
stamped. The local time is standardized throughout the
• The Layer 3 switching functions (optional) enable simple network by means of synchronization with a SICLOCK time
subdivision of large networks into smaller subnets with their transmitter or SNTP/NTP server, thereby simplifying the
own address space. Reasons for subdivision into subnets assignment of diagnostic messages of several devices.
include separation of the Ethernet network to reduce the
broadcast load, separation of sensitive areas from the main • Link Aggregation (IEEE 802.3ad) for bundling data streams
network, and subdivision of the network into logical working • Quality of Service (IEEE 802.1Q) for prioritization of network
groups. traffic
• Redundant Layer 3 connection to corporate networks;
SCALANCE XR-500 switches support the standardized
routing protocols Open Shortest Path First (OSPF) and
Routing Information Protocol (RIP), and the standardized
routing procedure Virtual Router Redundancy Protocol
(VRRP). This means industrial, routed subnets can also be
connected redundantly to a higher-level corporate network.
Engineering Station
Operator Station
SCALANCE 1000 Mbit/s SCALANCE 10 Gbit/s
1000 Mbit/s XR-500 10 Gbit/s XR-500 1000 Mbit/s
Link Aggregation
PC
10 Gbit/s
1000 Mbit/s
Operator Station PC
Industrial Ethernet 1000 Mbit/s
Field Level PoE PoE 100 100 100 Mbit/s 1000 Mbit/s 1000 Mbit/s 1000 Mbit/s
Mbit/s Mbit/s
SCALANCE ET
W-700 200S
G_IK10_XX_10299
S7-300 with
CP 343-1
ET 200S ET 200S ET 200pro ET 200S Lean
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
■ Function (continued)
Network topology and network configuration • Ethernet with fast media redundancy;
to increase network availability, as many as 50 X-200, X-300,
The network topology can easily be adapted to the structure of X-400 or X-500 switches cascaded in line can be connected
the plant using SCALANCE XR-500 Industrial Ethernet switches . into a ring.
The following network structures and combinations of structures
can be implemented:
• Several rings can be redundantly linked through the standby
function
2
• Star topology with SCALANCE XR-500 switches:
Each SCALANCE XR-500 switch represents a neutral point
that can connect up to 52 nodes or subnets with each other
electrically.
Server
1000 Mbit/s 1000 Mbit/s
10 Gbit/s 10 Gbit/s
SCALANCE SCALANCE
XR-500 OSPF XR-500
PC
Ring redundancy
Operator Station PC
10 Gbit/s
Industrial Ethernet
Engineering Station
SCALANCE
SCALANCE SCALANCE XR-300 SCALANCE XR-300
XM-400 XM-400
ET 200SP
G_IK10_XX_10298
SCALANCE XR-300 SCALANCE SCALANCE
1000 Mbit/s X-300 1000 Mbit/s X-300
Use of SCALANCE XR-500 in redundant network topologies, e.g. with Rapid Spanning Tree Protocol (RSTP) and ring redundancy
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
■ Function (continued)
Commissioning and diagnosis • The status of the signaling contact is routed externally by
means of floating relay contacts. This enables, for example,
Setting options on the device itself: the module to be monitored via an input module from a
• Redundancy manager RM; controller.
2 to establish a ring, a SCALANCE XR-500 is switched to
RM mode. The non-ring ports of the RM can be used freely for
• Monitoring via the Industrial Ethernet network;
the following possibilities are available:
the connection of data terminals and networks. If the redun- - Via standard browser (Web-based management):
dancy procedure MRP standardized by PROFINET is used, Selection of SCALANCE XR-500 switches via the network
the RM is adjusted automatically. from a PC with browser
• Signal mask; - Via SNMP V1, V2c, V3:
the signal mask is set to the current status of the Secure integration of SCALANCE XR-500 switches via the
SCALANCE XR-500 (setpoint) by pushbutton operation. network into a network management system, e.g. SINEMA
The signal mask defines which ports and which power Server
supplies are to be monitored. The signaling contact only - Via PROFINET IO diagnostics:
reports an error when a monitored port or a monitored feeder PROFINET diagnostic alarms from SCALANCE XR-500
fails (deviation of setpoint/actual status). switches can be displayed using the relevant SIMATIC
• IP address; engineering tools and they can also be processed in the
the IP address is assigned by means of dynamic host config- controller. The engineering outlay for the PLC and HMI have
uration protocol (DHCP). If there is no corresponding server in been drastically reduced due to the complete integration in
the network, the IP address can be assigned using an the SIMATIC concept for system error messages.
enclosed software tool. • Via the browser of a mobile device (smartphone, tablet)
Diagnostic options on site: Network management
• The following status information is displayed by LEDs on site: The network management provides the following functions:
- Port status
- Port mode (Mbps, full/half-duplex) • Password-protected dial-up for "Administrator" (read and write
- Status of the two power supplies authorization) and "User" (read only)
- Signaling contact status • Read-out of version and status information
- Signal mask (setpoint status) • Setting the signal and standby mask and address information
- RM mode
- Standby mode • Fixed parameterization of the ports (data rates, half/full
- Via the browser of a mobile device (smartphone, tablet) duplex)
• Setting of Spanning/Rapid/Multiple Spanning Tree parameters
• Parameterization of the web management services
• Security
- Ports can be connected or disconnected
- Port-based network access control according to
IEEE 802.1x
- Authentication in accordance with IEEE 802.1x
- Support of Access Control List (ACL)
• Output of statistics information
• Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
• Loading of new firmware versions or of the configuration data
via the network by a TFTP server or directly via HTTP/HTTPS
using a Web browser
• Saving the configuration data or log table via the network on a
TFTP server
If faults occur in the network, the SCALANCE XR-500 switch
can independently send error messages (traps) to a network
management system, such as SINEMA Server, or also e-mails to
a predefined network administrator.
Remote monitoring (RMON) provides the following functions:
The SCALANCE XR-500 switch can collect statistics information
according to the RMON groups 1 through 4. These include, for
example, fault statistics that are kept for each port. This informa-
tion can be read out through web-based management in the
statistics sub-area.
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
■ Technical specifications
Article No. 6GK5552-0AA00-2AR2 6GK5552-0AR00-2AR2 6GK5528-0AA00-2AR2 6GK5528-0AR00-2AR2
6GK5552-0AA00-2HR2 6GK5552-0AR00-2HR2 6GK5528-0AA00-2HR2 6GK5528-0AR00-2HR2
Product-type designation SCALANCE XR552-12M SCALANCE XR552-12M SCALANCE XR528-6M SCALANCE XR528-6M
Transmission rate
Transfer rate 1 10 Mbit/s 10 Mbit/s 10 Mbit/s 10 Mbit/s
2
Transfer rate 2 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Transfer rate 3 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Transfer rate 4 10 Gbit/s 10 Gbit/s 10 Gbit/s 10 Gbit/s
Interfaces
Number of electrical/optical 52 52 28 28
connections for network components
or terminal equipment maximum
Number of electrical connections
• for SFP+/SFP 4 4 4 4
• for operator console 1 1 1 1
• for management purposes 1 1 1 1
• for signaling contact 1 1 1 1
• for media module 12 12 6 6
• for power supply 1 1 1 1
• for redundant power supply 1 1 1 1
Design of electrical connection
• for network components Dependent on selected Dependent on selected Dependent on selected Dependent on selected
and terminal equipment media modules media modules media modules media modules
• for Power-over-Ethernet for network RJ45 port RJ45 port RJ45 port RJ45 port
components or terminal equipment
• for operator console RJ11 port RJ11 port RJ11 port RJ11 port
• for management purposes RJ45 port RJ45 port RJ45 port RJ45 port
• for signaling contact 2-pole terminal block 2-pole terminal block 2-pole terminal block 2-pole terminal block
• for power supply 4-pole terminal block 4-pole terminal block 4-pole terminal block 4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s Dependent on selected Dependent on selected Dependent on selected Dependent on selected
media modules media modules media modules media modules
• at 1 000 Mbit/s Dependent on selected Dependent on selected Dependent on selected Dependent on selected
media modules media modules media modules media modules
Design of the removable storage Yes Yes Yes Yes
C-PLUG/KEY-PLUG
Signal-Inputs/outputs
Operating voltage of signaling 24 V 24 V 24 V 24 V
contacts at DC rated value
Operating current of signaling 0.1 A 0.1 A 0.1 A 0.1 A
contacts at DC maximum
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC DC DC
Supply voltage external 24 V 24 V 24 V 24 V
• minimum 19.2 V 19.2 V 19.2 V 19.2 V
• maximum 28.8 V 28.8 V 28.8 V 28.8 V
Product component fusing Yes Yes Yes Yes
at power supply input
Type of fusing at input F 15 A / 125 V F 15 A / 125 V F 15 A / 125 V F 15 A / 125 V
for supply voltage
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
2 Protocol is supported
• Telnet Yes Yes Yes Yes
• HTTP Yes Yes Yes Yes
• HTTPS Yes Yes Yes Yes
• TFTP Yes Yes Yes Yes
• FTP Yes Yes Yes Yes
• BOOTP Yes Yes Yes Yes
• SNMP v1 Yes Yes Yes Yes
• SNMP v2 Yes Yes Yes Yes
• SNMP v3 Yes Yes Yes Yes
• IGMP (snooping/querier) Yes Yes Yes Yes
• GMRP Yes Yes Yes Yes
• DCP Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes Yes Yes
• I&M1 - higher level Yes Yes Yes Yes
designation/location designation
Product functions Diagnosis
Product function
• Port diagnostics Yes Yes Yes Yes
• Statistics packet size Yes Yes Yes Yes
• Statistics packet type Yes Yes Yes Yes
• Error statistics Yes Yes Yes Yes
• SysLog Yes Yes Yes Yes
Product functions VLAN
Product function
• VLAN - port based Yes Yes Yes Yes
• VLAN - protocol-based Yes Yes Yes Yes
• VLAN - IP-based Yes Yes Yes Yes
• VLAN dynamic Yes Yes Yes Yes
Number of VLANs maximum 255 255 255 255
Number of VLANs - 255 255 255 255
dynamic maximum
Protocol is supported GVRP Yes Yes Yes Yes
Product functions DHCP
Product function
• DHCP client Yes Yes Yes Yes
• DHCP Option 82 Yes Yes Yes Yes
• DHCP Option 66 Yes Yes Yes Yes
• DHCP Option 67 Yes Yes Yes Yes
Product functions Routing
Service Routing Note IP routing in connection IP routing in connection IP routing in connection IP routing in connection
with KEY-PLUG with KEY-PLUG with KEY-PLUG with KEY-PLUG
Product function
• static IP routing - - Yes Yes
• static IP routing IPv6 - - No No
• dynamic IP routing - - Yes Yes
• dynamic IP routing IPv6 - - No No
Protocol is supported
• RIPv2 - - Yes Yes
• RIPnG for IPv6 - - No No
• OSPFv2 - - Yes Yes
• OSPFv3 for IPv6 - - No No
• VRRP - - Yes Yes
• VRRP for IPv6 - - No No
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
■ Overview ■ Benefits
■ Application
Use of media modules in the SCALANCE X-500 switches
enables:
• Extension of networks by subsequent insertion of additional
media modules in unused media module slots (possible
during operation)
• Extension of networks by subsequent insertion of additional
SFP+ or SFP plug-in transceivers in unused SFP+ slots
(possible during operation)
• Changing of cabling technology (e.g. conversion from copper
to fiber-optic cables, or from multimode to singlemode FOC)
• Change of the data transfer rate (e.g. conversion from
• 4-port media modules for flexible, 4-port-granular equipping SFP plug-in transceivers (1 000 Mbit/s) to SFP+ plug-in trans-
of SCALANCE X-500 Industrial Ethernet switches ceivers (10 Gbit/s)
• Electrical versions with RJ45 ports are available as well as
optical versions with BFOC and SC ports for the use of multi-
mode and single-mode fiber-optic cables
• Using a 4-port SFP media module, the optional use of fiber-
optic SFP plug-in transceivers (small form-factor pluggable)
with LC connection technology is possible
• SFP+ and SFP plug-in transceivers for flexible equipping of
the four integral SFP+ slots in SCALANCE X-500
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
■ Design
2
Optical SFP+
pluggable transcei-
vers (one port) are SFP media modules
inserted into (four SFP slots) are
the device inserted into the device
Optical SFP
Optical
pluggable transceivers
4-port media modules
(one port) are inserted
are inserted into the
into the SFP media module
device
Electrical 4-port
media modules are
G_IK10_XX_10325
inserted into the device
4-port media modules plugged into media module slot and SFP/SFP+ plug-in transceivers in SFP+ slots
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
■ Design (continued)
Product versions of SFP+ pluggable transceivers Electrically preassembled SFP+/SFP+
The SFP+ pluggable transceivers (small form-factor pluggable) Connecting cable with 10 Gbit/s
can only be used in the integral SFP+ slots of the
The IE connecting cable SFP+/SFP+ is preassembled at both
2
SCALANCE X-500.
ends and suitable for the transmission of 10 Gbit/s Ethernet.
Optical SFP+ pluggable transceivers with The cables have SFP+ connectors for use in the SFP+ slots of
1 x 10 Gbit/s LC ports the SCALANCE X-500 series and therefore offer the possibility of
• SFP993-1 connecting SCALANCE X-500 switches cost-effectively over
multimode, glass, up to max 300 m short distances with a bandwidth of 10 Gbit/s. The SFP+/SFP+
connecting cables can only be used in the integrated SFP+ slots
• SFP993-1LD of the SCALANCE X-500.
single-mode, glass, up to 10 km
• IE connecting cable SFP+/SFP+ 1 m;
• SFP993-1LH Twinax copper cable with a length of 1 m
singlemode, glass, up to max 40 km
• IE connecting cable SFP+/SFP+ 2 m;
Twinax copper cable with a length of 2 m
• IE connecting cable SFP+/SFP+ 7 m;
Twinax copper cable with a length of 7 m
SFPplus-Module4)
SFP993-1 1x LC 300 m
SFP993-1LD 1x LC 10 km
SFP993-1LH 1x LC 40 km
1) With retaining collars
2) The MM992-4SFP SFP slot module can accommodate up to four 1-port SFP modules
3) Can only be plugged into an MM992-4SFP slot module
4) Puggable in XR-500 SFPplus slots only
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
■ Technical specifications
Article No. 6GK5992-4GA00-8AA0 6GK5992-4SA00-8AA0 6GK5992-4RA00-8AA0 6GK5992-4QA00-8AA0
Product-type designation MM992-4CUC MM992-4CU MM992-4POEC MM992-4POE
Interfaces
2 Number of electrical/optical
connections for network components
4 4 4 4
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
2 ST(BFOC) ports
Number of 100 Mbit/s SC ports - -
Number of 100 Mbit/s LC ports - -
Number of 1 000 Mbit/s LC ports (LX) - -
Number of 1 000 Mbit/s LC ports (SX) - -
Number of 1 000 Mbit/s SC ports (LX) - -
Number of 1 000 Mbit/s SC ports (SX) - -
Number of 10 Gbit/s LC ports (LX) - -
Number of 10 Gbit/s LC ports (SX) - -
Design of optical connections BFOC BFOC
for network components or terminal
devices
Connectable optical power relative
to 1 mW
• of the transmitter output -19 … -14 dB -15 … -8 dB
• of the receiver input -3 dB -3 dB
Optical sensitivity relative to 1 mW -32 dB -34 dB
of the receiver input minimum
Attenuation of fiber-optic cable 0 dB 0 dB
transmission link minimum necessary
Range at the optical interface 0 ... 5 km 0 ... 26 km
depending on the optical fiber used
Permitted ambient conditions
Ambient temperature
• during operating 0 … 60 °C 0 … 60 °C
• during storage -40 ... +70 °C -40 ... +70 °C
• during transport -40 ... +70 °C -40 ... +70 °C
Relative humidity at 25 °C without 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) - -
operation mode
Protection class IP IP20 IP20
Design, dimensions and weight
Design Media module Media module
Width 120.3 mm 120.3 mm
Height 22.3 mm 22.3 mm
Depth 275.5 mm 275.5 mm
Net weight 0.3 kg 0.3 kg
Mounting type Installation in media Yes Yes
module slot
Mounting type Latched Latched
Standards, specifications,
approvals
Standard
• for EMC - -
• for EMC from FM - -
• for hazardous zone - -
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL - -
• for emitted interference EN 61000-6-4 (Class A) EN 61000-6-4 (Class A)
• for interference immunity EN 61000-6-2 EN 61000-6-2
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
2 Ambient temperature
• during operating 0 … 60 °C 0 … 60 °C 0 … 60 °C
• during storage -40 ... 70 °C -40 ... 70 °C -40 ... 70 °C
• during transport -40 ... 70 °C -40 ... 70 °C -40 ... 70 °C
Relative humidity at 25 °C without 95 % 95 % 95 %
condensation during operating
maximum
Ambient condition for (standard) - - -
operation mode
Protection class IP IP20 IP20 IP20
Design, dimensions and weight
Design Media module Media module Media module
Width 120.3 mm 120.3 mm 120.3 mm
Height 22.3 mm 22.3 mm 22.3 mm
Depth 275.5 mm 275.5 mm 275.5 mm
Net weight 0.3 kg 0.3 kg 0.3 kg
Mounting type Installation Yes Yes Yes
in media module slot
Mounting type Latched Latched Latched
Standards, specifications,
approvals
Standard
• for EMC - - -
• for EMC from FM - - -
• for hazardous zone - - -
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-2 UL 60950-1, CSA C22.2 No. 60950-3
• for hazardous area of CSA and UL - - -
• for emitted interference EN 61000-6-4 (Class A) EN 61000-6-4 (Class A) EN 61000-6-4 (Class A)
• for interference immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Verification of suitability EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-5 EN 61000-6-2, EN 61000-6-6
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval Yes Yes Yes
• Railway application in accordance - - -
with EN 50155
• Railway application in accordance - - -
with EN 50124-1
• IEC 61850-3 - - -
Marine classification association
• American Bureau of Shipping Eu- - - -
rope Ltd. (ABS)
• Bureau Veritas (BV) - - -
• Det Norske Veritas (DNV) - - -
• Germanische Lloyd (GL) - - -
• Lloyds Register of Shipping (LRS) - - -
• Nippon Kaiji Kyokai (NK) - - -
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
2 approvals
Standard
• for EMC - - -
• for EMC from FM FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A, FM3611: Class 1, Division 2, Group A,
B, C, D / T4, Class 1, Zone 2, B, C, D / T4, Class 1, Zone 2, B, C, D / T4, Class 1, Zone 2,
Group IIC, T4 Group IIC, T4 Group IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0: 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4, EN 60079-15: 2005, II 3 G Ex nA II T4, EN 60079-15: 2005, II 3 G Ex nA II T4,
KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X
• for safety of CSA and UL UL 60950-1, UL 60950-1, UL 60950-1,
CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03 CSA C22.2 No. 60950-1-03
• for hazardous area of CSA and UL - - -
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-2:2005, EN 61000-6-2:2005,
EN 61000-6-4:2007 EN 61000-6-4:2007 EN 61000-6-4:2007
• CE mark Yes Yes Yes
• C-Tick Yes Yes Yes
• KC approval No No No
• Railway application in accordance - - -
with EN 50155
• Railway application in accordance - - -
with EN 50124-1
• IEC 61850-3 - - -
Marine classification association
• American Bureau - - -
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) - - -
• Det Norske Veritas (DNV) - - -
• Germanische Lloyd (GL) - - -
• Lloyds Register of Shipping (LRS) - - -
• Nippon Kaiji Kyokai (NK) - - -
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
2 approvals
Standard
• for EMC - -
• for EMC from FM FM3611: Class 1, Division 2, Group A, B, C, D / T4, FM3611: Class 1, Division 2, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, T4 Class 1, Zone 2, Group IIC, T4
• for hazardous zone EN 60079-0: 2006, EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4, EN 60079-15: 2005, II 3 G Ex nA II T4,
KEMA 07 ATEX 0145 X KEMA 07 ATEX 0145 X
• for safety of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1-03 UL 60950-1, CSA C22.2 No. 60950-1-03
• for hazardous area of CSA and UL - -
• for emitted interference EN 61000-6-4:2007 (Class A) EN 61000-6-4:2007 (Class A)
• for interference immunity EN 61000-6-2:2005 EN 61000-6-2:2005
Verification of suitability EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61000-6-2:2005, EN 61000-6-4:2007
• CE mark Yes Yes
• C-Tick Yes Yes
• KC approval No No
• Railway application in accordance - -
with EN 50155
• Railway application in accordance - -
with EN 50124-1
• IEC 61850-3 - -
Marine classification association
• American Bureau - -
of Shipping Europe Ltd. (ABS)
• Bureau Veritas (BV) - -
• Det Norske Veritas (DNV) - -
• Germanische Lloyd (GL) - -
• Lloyds Register of Shipping (LRS) - -
• Nippon Kaiji Kyokai (NK) - -
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
■ More information
Selection tool:
To assist in selecting the right Industrial Ethernet switches
as well as configuration of modular variants, the SIMATIC NET
Selection Tool and the TIA Selection Tool are available at:
SIMATIC NET Selection Tool:
2
• Online version:
http://www.siemens.com/snst
• Offline version:
http://www.siemens.com/snst-download
TIA Selection Tool:
http://www.siemens.com/tia-selection-tool
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Power supplies for SCALANCE X-500
■ Overview ■ Design
• Non-heating apparatus socket for connecting to the AC
network of 85 to 264 V AC (non-heating apparatus cable not
included in the scope of delivery; can be ordered optionally on
country-specific basis)
2 • Terminal block for universal supply of products with 24 V DC
input
• Plug-in contact for direct connection on the rear of the
SCALANCE XR-500 Industrial Ethernet switches (mounting kit
included in scope of delivery of SCALANCE XR-500)
• Operating temperatures from 0°C to +60°C
• IP20 degree of protection
• Optimized for installation in 19" control cabinet or for direct
• The 24 V PS598 power supply is designed for installation mounting on SCALANCE XR-500 (SCALANCE XR-500 and
in 19" control cabinets or for direct mounting on power supply unit are mounted in the 19" control cabinet as a
SCALANCE XR-500 Industrial Ethernet switches; single unit)
it has degree of protection IP20. • LEDs for indicating the status information
• 300 W output power at an input voltage range of 85 V to (power, operating state)
264 V AC and an operating temperature of 0 °C to +60 °C
Product versions
■ Integration
PS598-1 24 V power supply
• 300 W output power
• Input voltage range from 85 V to 264 V AC
• Output voltage 24 V DC
• Operating temperature from 0 °C to +60 °C
• Degree of protection IP20
■ Benefits XR552-12M
with basic power supply,
XR552-12M
with redundant power supply,
bottom mounting bottom mounting
G_IK10_XX_10324
XR552-12M XR552-12M
with basic power supply, with redundant power supply,
rear mounting rear mounting
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Power supplies for SCALANCE X-500
■ Technical specifications
Article No. 6GK5598-1AA00-3AA0 Article No. 6GK5598-1AA00-3AA0
Product-type designation POWER SUPPLY PS598-1 Product-type designation POWER SUPPLY PS598-1
Type of current supply 300 W, Electrical data
Electrical data
input: 85 - 264 V, output: DC 24 V Closed-loop control
Relative regulation accuracy
2
of the output voltage
Electrical data
Input • with rapid fluctuation of the input 0.8 %
voltage by +/- 15% typical
Form of voltage at the input 1-phase AC • load step of ohmic load 50/100/50 % 3.25 %
Supply voltage typical
• for AC 85 … 264 V Setting time
• 1 at AC nominal value 230 V • load step 50 to 100% typical 2 ms
Type of input wide range input Yes • load step 100 to 50% typical 2 ms
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Power supplies for SCALANCE X-500
2
cabinets or for direct mounting on
Ambient temperature SCALANCE X-500 Industrial
• during operating 0 … 60 °C Ethernet switches;
• during storage -25 … +70 °C degree of protection IP20
• during transport -25 … +70 °C PS598-1 6GK5598-1AA00-3AA0
• Comment Operation with integral fan, 300 W output power,
non-replaceable input voltage range of
Climatic class Climate class 3K3, 85 V to 264 V AC,
according to EN 60721 without condensation operating temperature
of 0 °C to +60 °C
Protection class IP IP20
Accessories
Standards, specifications,
approvals Appliance cable
Standard • Grounded Continental European 6ES7900-0AA00-0XA0
• for EMC - plug,
region: D/F/NL/ESP/B/A/S/FIN
• for EMC from FM -
• for hazardous zone - • Grounded British plug; 6ES7900-0BA00-0XA0
• for safety of CSA and UL UL 60950-1, CSA C22.2 Nr. 60950-1 region: UK
• for hazardous area of CSA and UL - • Grounded Swiss plug; 6ES7900-0CA00-0XA0
• for emitted interference EN 55022 (Class B) region: CH
• for interference immunity EN 61000-6-2 • Grounded North American and 6ES7900-0DA00-0XA0
Japanese plug;
Verification of suitability EN 55022, EN 61000-6-4
region: USA
• CE mark Yes
• C-Tick Yes • Grounded Italian plug; 6ES7900-0EA00-0XA0
region: Italy
• Grounded Chinese plug; 6ES7900-0FA00-0XA0
region: China
PROFINET/Industrial Ethernet
Accessories for Layer 3 switches / routers
KEY-PLUG X-500, XM-400
■ Integration
Supported products
• Swap medium with which Layer 3 Routing functions can be
SCALANCE X-500
enabled
• For the automatic backup of configuration data. If a fault SCALANCE XM-400
occurs, it allows fast and simple device replacement without a
Field PG (contains the function of the C-PLUG) ■ Technical specifications
• Can be used in all Layer 2 variants of the SCALANCE XR500
and in all variants of the SCALANCE XM-400 basic devices KEY-PLUG
Supply voltage via terminal device
■ Benefits Power loss 0.015 mW
• Fast and simple replacement of SCALANCE X-500 or Installation Can be plugged
SCALANCE XM-400 components without reconfiguration of into C-PLUG compartment
the spare part Construction
• The device can be replaced without the need for specially • Dimensions (W x H x D) in mm 24.3 x 17 x 8.1
trained personnel or a programming device or PC • Approx. weight 5g
• The downtimes of network segments and connected Industrial Memory capacity 256 MB
Ethernet nodes can therefore be minimized if a fault occurs Degree of protection IP20
■ Application
■ Ordering data Article No.
The KEY-PLUG stores the configuration data of a
SCALANCE X-500 or SCALANCE XM-400 component. KEY-PLUG X-500
Additional Layer 3 Routing functions can be enabled by insert- Layer 3 Routing
ing a KEY-PLUG. KEY-PLUG XR-500, swap medium
for enabling Layer 3 Routing
In addition to this, if there is a fault on a module, the module can Features for SCALANCE XR-500
be replaced simply and quickly without needing to reconfigure and for easily replacing a device in
the replacement device and without specially trained personnel. the event of a failure as well as for
If a device needs to be replaced, the KEY-PLUG is simply recording configuration data.
removed from the failed component and plugged into the re- • For SCALANCE XR552, 6GK5905-0PA00
placement device. The replacement device now starts up auto- SCALANCE XR528 and XR524
matically with the device configuration of the failed device. KEY-PLUG XM-400 6GK5904-0PA00
Layer 3 Routing
■ Design KEY-PLUG XM-400, swap medium
for enabling Layer 3 Routing
The KEY-PLUG has degree of protection IP20. Power is supplied Features for SCALANCE XM-400
by the terminal device. and for easily replacing a device in
the event of a failure as well as for
The KEY-PLUG is plugged into the slot of the SCALANCE X-500 recording configuration data.
or SCALANCE XM-400 basic device provided for this purpose.
PROFINET/Industrial Ethernet
SINAMICS drive system
Overview
■ Overview
The SINAMICS range
• Totally integrated range of drives for any application and every
industry
2 • Wide range of power ratings from 0.12 kW to 120 MW
• Broad functional scope from simple U/f control through to
highly dynamic servo control
• Designed for problem-free interaction with other Siemens
automation components
• Shared platform concept with uniform functionality,
engineering, commissioning, operation as well as a uniform
diagnostics concept and communication mechanisms
SINAMICS G SINAMICS S
G120C G120P/ G120 G110M G120D S110 S120
G120
Compact CU230P-2 CU240E-2 CU250S-2 CU240M CU240D-2 CU250D-2 CU305 CU310-2 CU320-2
inverters Control Control Control Control Control Control Control Control Control
Unit Unit Unit Unit Unit Unit Unit Unit Unit
Protocol
PROFINET
- PROFINET RT
- PROFINET IRT (not isochronous)
- PROFINET IRT isochronous – – – – – – –
- PROFINET Shared Device
- PROFINET media redundancy
MRP (surge prone)
- PROFINET media redundancy
MRPD (surge free)
• Profile
- PROFIsafe –
- PROFIenergy –
- PROFIdrive
PROFINET/Industrial Ethernet
SINAMICS drive system
Overview
■ Overview (continued)
SINAMICS G120D – the distributed single-motor drive for high-performance solutions
• Positioning capability
• Power range from 0.75 kW to 7.5 kW
• Energy efficient thanks to regenerative feedback and low line
harmonic distortion
2
• Safety Integrated: STO, SS1, SDI, SSM and SLS encoderless
• Thanks to the modular design, electronics stocks are minimal
• Interchangeable memory card
• Communication via PROFIBUS DP, PROFINET, EtherNet/IP
• Integrated in the TIA Portal with SINAMICS Startdrive
More information
• Catalog D 31
• Interactive Catalog CA 01
• Internet:
www.siemens.com/sinamics-g120d
www.siemens.com/industrymall
SINAMICS G120C – the compact and versatile inverter with optimum functionality
• Compact unit
• Highest power density in its class
• Power range from 0.55 kW to 18.5 kW
• Easy commissioning and maintenance
• With BOP-2 or IOP operator panel
• Safety Integrated: STO
• Available communication: PROFIBUS DP, CANopen, USS,
Modbus RTU, PROFINET, EtherNet/IP
• Integrated in the TIA Portal with SINAMICS Startdrive
More information
• Catalog D 31
• Interactive Catalog CA 01
• Internet:
www.siemens.com/sinamics-g120c
www.siemens.com/industrymall
SINAMICS G120 – the modular single-motor drive for low to medium power ratings
• Power range from 0.37 kW to 250 kW
• Safety Integrated: STO, SS1, SBC, SLS, SDI and SSM
encoderless
• Communication via PROFIBUS, PROFINET, EtherNet/IP,
RS485, USS, Modbus RTU, CANopen, BACnet MS/TP
• Energy efficient thanks to regenerative feedback and low line
harmonic distortion
• Parameter copy function for standard commissioning
• Integrated in the TIA Portal with SINAMICS Startdrive
More information
• Catalog D 31
• Interactive Catalog CA 01
• Internet:
www.siemens.com/sinamics-g120
www.siemens.com/industrymall
PROFINET/Industrial Ethernet
SINAMICS drive system
Overview
■ Overview (continued)
SINAMICS G110M – the distributed inverter integrated in the motor
• Power range from 0.37 kW to 4 kW
• Integrated safety functions (STO locally via F-DI or via
2 PROFIsafe)
• Integrated communication: USS, Modbus RTU, PROFIBUS,
PROFINET, EtherNet/IP
• Basic PLC functions and additional conveyor technology
functions
• Local commissioning via DIP switch and potentiometer,
memory card, USB interface or Intelligent Operator Panel
(IOP)
• Integrated in the TIA Portal with SINAMICS Startdrive
More information
• Catalog D 31
• Interactive Catalog CA 01
• Internet:
www.siemens.com/sinamics-g110m
www.siemens.com/industrymall
PROFINET/Industrial Ethernet
Measuring systems
Overview
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1211C
■ Overview
• The clever compact solution
• With 10 integral input/outputs
• Expandable by:
2 - 1 signal board (SB) or communication board (CB)
- Max. 3 communication modules (CM)
■ Technical specifications
6ES7211-1BE40-0XB0 6ES7211-1AE40-0XB0 6ES7211-1HE40-0XB0
CPU 1211C AC/DC/Relay CPU 1211C DC/DC/DC CPU 1211C DC/DC/Relay
General information
Engineering with
• Programming package STEP 7 V13 or higher STEP 7 V13 or higher STEP 7 V13 or higher
Supply voltage
24 V DC Yes Yes
120 V AC Yes
230 V AC Yes
Power losses
Power loss, typ. 10 W 8W 8W
Memory
Work memory
• integrated 30 kbyte 30 kbyte 30 kbyte
Load memory
• integrated 1 Mbyte 1 Mbyte 1 Mbyte
• plug-in (SIMATIC Memory Card), 2 Gbyte; 2 Gbyte; 2 Gbyte;
max. with SIMATIC Memory Card with SIMATIC Memory Card with SIMATIC Memory Card
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.085 µs; / Operation 0.085 µs; / Operation 0.085 µs; / Operation
for word operations, typ. 1.7 µs; / Operation 1.7 µs; / Operation 1.7 µs; / Operation
for floating point arithmetic, typ. 2.3 µs; / Operation 2.3 µs; / Operation 2.3 µs; / Operation
Data areas and their retentivity
Flag
• Number, max. 4 kbyte; 4 kbyte; 4 kbyte;
Size of bit memory address area Size of bit memory address area Size of bit memory address area
Address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1211C
2
Number of digital inputs 6; integrated 6; integrated 6; integrated
• of which, inputs usable 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
for technological functions
Digital outputs
Number of digital outputs 4; Relays 4 4; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Integrated channels (AI) 2; 0 to 10 V 2; 0 to 10 V 2; 0 to 10 V
Input ranges
• Voltage Yes Yes Yes
1st interface
Interface type PROFINET PROFINET PROFINET
Physics Ethernet Ethernet Ethernet
Functionality
• PROFINET IO Device Yes Yes Yes
• PROFINET IO Controller Yes Yes Yes
Communication functions
S7 communication
• supported Yes Yes Yes
Open IE communication
• TCP/IP Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
Integrated Functions
Number of counters 6 6 6
Counter frequency (counter) max. 100 kHz 100 kHz 100 kHz
Frequency meter Yes Yes Yes
Controlled positioning Yes Yes Yes
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Operating temperature
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 90 mm 90 mm 90 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 420 g 370 g 380 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1211C
2
25 KB, load memory 1 MB; 2 transistor outputs 24 V DC,
Wide-range AC power supply 0.5 A, 5 W;
85 ... 264 V AC; Can be used as HSC
Boolean execution times 0.1 s at up to 30 kHz
per operation;
6 digital inputs, 2 inputs, 5 V DC, 200 kHz 6ES7223-3AD30-0XB0
4 digital outputs (relays), 2 outputs, 5 V DC, 0.1 A, 200 kHz
2 analog inputs; 2 inputs, 24 V DC, 200 kHz 6ES7223-3BD30-0XB0
Expandable with up to 2 outputs, 24 V DC, 0.1 A, 200 kHz
3 communication modules and
1 signal board/communication SB 1231 signal board 6ES7231-4HA30-0XB0
board;
1 analog input, ±10 V with 12 bits
Digital inputs can be used
or 0 ... 20 mA with 11 bits
as HSC at 100 kHz
Thermocouple signal board 6ES7231-5QA30-0XB0
Compact CPU, DC/DC/DC; 6ES7211-1AE40-0XB0
SB 1231
Integrated program/data memory
25 KB, load memory 1 MB; 1 input +/- 80 mV,
Supply voltage 24 V DC; resolution 15 bits + sign,
Boolean execution times 0.1 s thermocouples type J, K
per operation;
6 digital inputs, RTD signal board SB 1231 6ES7231-5PA30-0XB0
4 digital outputs, 1 input for resistance temperature
2 analog inputs; sensors Pt 100, Pt 200, Pt 500,
Expandable with up to Pt 1000, resolution 15 bits + sign
3 communication modules and
1 signal board/communication SB 1232 signal board 6ES7232-4HA30-0XB0
board;
Digital inputs can be used 1 analog output, ±10 V with 12 bits
as HSC at 100 kHz, or 0 to 20 mA with 11 bits
24 V DC digital outputs can be Communication board CB 1241 6ES7241-1CH30-1XB0
used as pulse outputs (PTO) or as RS485
outputs with pulse width modulation
(PWM) at 100 kHz for point-to-point connection,
with 1 RS485 interface
Compact CPU, DC/DC/relay; 6ES7211-1HE40-0XB0
Integrated program/data memory Simulator (optional) 6ES7274-1XF30-0XA0
25 KB, load memory 1 MB; 8 input switches,
Supply voltage 24 V DC; for CPU 1211C / CPU 1212C
Boolean execution times 0.1 s
per operation; SIMATIC Memory Card (optional)
6 digital inputs,
4 digital outputs (relays), 4 MB 6ES7954-8LC02-0AA0
2 analog inputs; 12 MB 6ES7954-8LE02-0AA0
Expandable with up to
3 communication modules and 24 MB 6ES7954-8LF02-0AA0
1 signal board/communication
256 MB 6ES7954-8LL02-0AA0
board;
Digital inputs can be used 2 GB 6ES7954-8LP01-0AA0
as HSC at 100 kHz
Terminal block (spare part)
SB 1221 signal board
for CPU 1211C/1212C
4 inputs, 5 V DC, 200 kHz 6ES7221-3AD30-0XB0
For DI, with 14 screws, tin-plated; 6ES7292-1AH30-0XA0
4 inputs, 24 V DC, 200 kHz 6ES7221-3BD30-0XB0 4 units
SB 1222 signal board For DO, with 8 screws, tin-plated; 6ES7292-1AP30-0XA0
4 outputs, 5 V DC, 0.1 A, 200 kHz 6ES7222-1AD30-0XB0 4 units
4 outputs, 24 V DC, 0.1 A, 200 kHz 6ES7222-1BD30-0XB0 For AI, with 3 screws, tin-plated; 6ES7292-1BC30-0XA0
4 units
RJ45 cable grip 6ES7290-3AA30-0XA0
4 units per pack
Single port
Front flap set (spare part) 6ES7291-1AA30-0XA0
for CPU 1211C/1212C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1211C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1212C
■ Overview
• The superior compact solution
• With 14 integral input/outputs
• Expandable by:
2 - 1 signal board (SB) or communication board (CB)
- 2 signal modules (SM)
- Max. 3 communication modules (CM)
■ Technical specifications
6ES7212-1BE40-0XB0 6ES7212-1AE40-0XB0 6ES7212-1HE40-0XB0
CPU 1212C AC/DC/Relay CPU 1212C DC/DC/DC CPU 1212C DC/DC/Relay
General information
Engineering with
• Programming package STEP 7 V13 or higher STEP 7 V13 or higher STEP 7 V13 or higher
Supply voltage
24 V DC Yes Yes
120 V AC Yes
230 V AC Yes
Power losses
Power loss, typ. 11 W 9W 9W
Memory
Work memory
• integrated 50 kbyte 50 kbyte 50 kbyte
Load memory
• integrated 1 Mbyte 1 Mbyte 1 Mbyte
• plug-in (SIMATIC Memory Card), 2 Gbyte; 2 Gbyte; 2 Gbyte;
max. with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.085 µs; / Operation 0.085 µs; / Operation 0.085 µs; / Operation
for word operations, typ. 1.7 µs; / Operation 1.7 µs; / Operation 1.7 µs; / Operation
for floating point arithmetic, typ. 2.3 µs; / Operation 2.3 µs; / Operation 2.3 µs; / Operation
Data areas and their retentivity
Flag
• Number, max. 4 kbyte; 4 kbyte; 4 kbyte;
Size of bit memory address area Size of bit memory address area Size of bit memory address area
Address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1212C
2
Number of digital inputs 8; integrated 8; integrated 8; integrated
• of which, inputs usable 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
for technological functions
Digital outputs
Number of digital outputs 6; Relays 6 6; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Integrated channels (AI) 2; 0 to 10 V 2; 0 to 10 V 2; 0 to 10 V
Input ranges
• Voltage Yes Yes Yes
1st interface
Interface type PROFINET PROFINET PROFINET
Physics Ethernet Ethernet Ethernet
Functionality
• PROFINET IO Device Yes Yes Yes
• PROFINET IO Controller Yes Yes Yes
Communication functions
S7 communication
• supported Yes Yes Yes
Open IE communication
• TCP/IP Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
Integrated Functions
Number of counters 4 6 6
Counter frequency (counter) max. 100 kHz 100 kHz 100 kHz
Frequency meter Yes Yes Yes
Controlled positioning Yes Yes Yes
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Operating temperature
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 90 mm 90 mm 90 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 425 g 370 g 385 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1212C
2
25 KB, load memory 1 MB; 2 transistor outputs 24 V DC,
Wide-range AC power supply 0.5 A, 5 W;
85 ... 264 V AC; Can be used as HSC at
Boolean execution times 0.1 s up to 30 kHz
per operation;
8 digital inputs, 2 inputs, 5 V DC, 200 kHz 6ES7223-3AD30-0XB0
6 digital outputs (relays), 2 outputs, 5 V DC, 0.1 A, 200 kHz
2 analog inputs; 2 inputs, 24 V DC, 200 kHz 6ES7223-3BD30-0XB0
Expandable with up to 2 outputs, 24 V DC, 0.1 A, 200 kHz
3 communication modules,
2 signal modules and 1 signal SB 1231 signal board 6ES7231-4HA30-0XB0
board/communication board;
1 analog input, ±10 V with 12 bits
Digital inputs can be used as HSC
or 0 ... 20 mA with 11 bits
at 100 kHz
Thermocouple signal board 6ES7231-5QA30-0XB0
Compact CPU, DC/DC/DC; 6ES7212-1AE40-0XB0
SB 1231
Integrated program/data memory
25 KB, load memory 1 MB; 1 input +/- 80 mV,
Supply voltage 24 V DC; resolution 15 bits + sign,
Boolean execution times 0.1 s thermocouples type J, K
per operation;
8 digital inputs, 6 digital outputs, RTD signal board SB 1231 6ES7231-5PA30-0XB0
2 analog inputs; 1 input for resistance temperature
Expandable with up to sensors Pt 100, Pt 200, Pt 500,
3 communication modules, Pt 1000, resolution 15 bits + sign
2 signal modules and 1 signal
board/communication board; SB 1232 signal board 6ES7232-4HA30-0XB0
Digital inputs can be used
as HSC at 100 kHz, 1 analog output, ±10 V with 12 bits
24 V DC digital outputs can be or 0 to 20 mA with 11 bits
used as pulse outputs (PTO) Communication board 6ES7241-1CH30-1XB0
or as outputs with pulse width CB 1241 RS485
modulation (PWM)
at 100 kHz for point-to-point connection,
with 1 RS485 interface
Compact CPU, DC/DC/relay; 6ES7212-1HE40-0XB0
Integrated program/data memory Simulator (optional) 6ES7274-1XF30-0XA0
25 KB, load memory 1 MB; 8 input switches,
Supply voltage 24 V DC; for CPU 1211C / CPU 1212C
Boolean execution times 0.1 s
per operation; SIMATIC Memory Card (optional)
8 digital inputs,
6 digital outputs (relays), 4 MB 6ES7954-8LC02-0AA0
2 analog inputs; 12 MB 6ES7954-8LE02-0AA0
Expandable with up to
3 communication modules, 24 MB 6ES7954-8LF02-0AA0
2 signal modules and 1 signal
256 MB 6ES7954-8LL02-0AA0
board/communication board;
Digital inputs can be used as HSC 2 GB 6ES7954-8LP01-0AA0
at 100 kHz
Extension cable 6ES7290-6AA30-0XA0
SB 1221 signal board for two-tier configuration
4 inputs, 5 V DC, 200 kHz 6ES7221-3AD30-0XB0 For connecting digital/analog
4 inputs, 24 V DC, 200 kHz 6ES7221-3BD30-0XB0 signal modules;
2 m long
SB 1222 signal board
Starter box CPU 1212C 6ES7212-1BD33-4YB0
4 outputs, 5 V DC, 0.1 A, 200 kHz 6ES7222-1AD30-0XB0 AC/DC/relay
4 outputs, 24 V DC, 0.1 A, 200 kHz 6ES7222-1BD30-0XB0 Complete offer SIMATIC S7-1200,
starter box, comprising:
CPU 1212C AC/DC/relay, simulator,
STEP 7 BASIC CD, manual CD,
info material, in Systainer
Terminal block (spare part)
for CPU 1211C/1212C
For DI, with 14 screws, tin-plated; 6ES7292-1AH30-0XA0
4 units
For DO, with 8 screws, tin-plated; 6ES7292-1AP30-0XA0
4 units
For AI, with 3 screws, tin-plated; 6ES7292-1BC30-0XA0
4 units
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1212C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1214C
■ Overview
• The compact high-performance CPU
• With 24 integral input/outputs
• Expandable by:
2 - 1 signal board (SB) or communication board (CB)
- 8 signal modules (SM)
- Max. 3 communication modules (CM)
■ Technical specifications
6ES7214-1BG40-0XB0 6ES7214-1AG40-0XB0 6ES7214-1HG40-0XB0
CPU 1214C AC/DC/Relay CPU 1214C DC/DC/DC CPU 1214C DC/DC/Relay
General information
Engineering with
• Programming package STEP 7 V13 or higher STEP 7 V13 or higher STEP 7 V13 or higher
Supply voltage
24 V DC Yes Yes
120 V AC Yes
230 V AC Yes
Power losses
Power loss, typ. 14 W 12 W 12 W
Memory
Work memory
• integrated 75 kbyte 75 kbyte 75 kbyte
Load memory
• integrated 4 Mbyte 4 Mbyte 4 Mbyte
• plug-in (SIMATIC Memory Card), 2 Gbyte; 2 Gbyte; 2 Gbyte;
max. with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.085 µs; / Operation 0.085 µs; / Operation 0.085 µs; / Operation
for word operations, typ. 1.7 µs; / Operation 1.7 µs; / Operation 1.7 µs; / Operation
for floating point arithmetic, typ. 2.3 µs; / Operation 2.3 µs; / Operation 2.3 µs; / Operation
Data areas and their retentivity
Flag
• Number, max. 8 kbyte; 8 kbyte; 8 kbyte;
Size of bit memory address area Size of bit memory address area Size of bit memory address area
Address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1214C
2
Number of digital inputs 14; integrated 14; integrated 14; integrated
• of which, inputs usable 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
for technological functions
Digital outputs
Number of digital outputs 10; Relays 10 10; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Integrated channels (AI) 2; 0 to 10 V 2; 0 to 10 V 2; 0 to 10 V
Input ranges
• Voltage Yes Yes Yes
1st interface
Interface type PROFINET PROFINET PROFINET
Physics Ethernet Ethernet Ethernet
Functionality
• PROFINET IO Device Yes Yes Yes
• PROFINET IO Controller Yes Yes Yes
Communication functions
S7 communication
• supported Yes Yes Yes
Open IE communication
• TCP/IP Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
Integrated Functions
Number of counters 6 6 6
Counter frequency (counter) max. 100 kHz 100 kHz 100 kHz
Frequency meter Yes Yes Yes
Controlled positioning Yes Yes Yes
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4 4 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Operating temperature
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 110 mm 110 mm 110 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 475 g 415 g 435 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1214C
2
50 KB, load memory 2 MB; 2 transistor outputs 24 V DC,
Wide-range AC power supply 0.5 A, 5 W;
85 ... 264 V AC; Can be used as HSC at
Boolean execution times 0.1 s up to 30 kHz
per operation;
14 digital inputs, 2 inputs, 5 V DC, 200 kHz 6ES7223-3AD30-0XB0
10 digital outputs (relays), 2 outputs, 5 V DC, 0.1 A, 200 kHz
2 analog inputs; 2 inputs, 24 V DC, 200 kHz 6ES7223-3BD30-0XB0
Expandable with up to 2 outputs, 24 V DC, 0.1 A, 200 kHz
3 communication modules,
8 signal modules and 1 signal SB 1231 signal board 6ES7231-4HA30-0XB0
board/communication board;
1 analog input, ±10 V with 12 bits
Digital inputs can be used as HSC
or 0 ... 20 mA with 11 bits
at 100 kHz
Thermocouple signal board 6ES7231-5QA30-0XB0
Compact CPU, DC/DC/DC; 6ES7214-1AG40-0XB0
SB 1231
Integrated program/data memory
50 KB, load memory 2 MB; 1 input +/- 80 mV,
Supply voltage 24 V DC; resolution 15 bits + sign,
Boolean execution times 0.1 s thermocouples type J, K
per operation;
14 digital inputs, RTD signal board SB 1231 6ES7231-5PA30-0XB0
10 digital outputs, 1 input for resistance temperature
2 analog inputs; sensors Pt 100, Pt 200, Pt 500,
Expandable with up to Pt 1000, resolution 15 bits + sign
3 communication modules,
8 signal modules and 1 signal SB 1232 signal board 6ES7232-4HA30-0XB0
board/communication board;
Digital inputs can be used as HSC 1 analog output, ±10 V with 12 bits
at 100 kHz, or 0 to 20 mA with 11 bits
24 V DC digital outputs can be Communication board CB 1241 6ES7241-1CH30-1XB0
used as pulse outputs (PTO) RS485
or as outputs with pulse-width
modulation (PWM) for point-to-point connection,
at 100 kHz with 1 RS485 interface
Compact CPU, DC/DC/relay; 6ES7214-1HG40-0XB0 Simulator (optional) 6ES7274-1XH30-0XA0
Integrated program/data memory 14 input switches, for CPU 1214C
50 KB, load memory 2 MB;
Supply voltage 24 V DC; SIMATIC Memory Card (optional)
Boolean execution times 0.1 s
per operation; 4 MB 6ES7954-8LC02-0AA0
14 digital inputs, 12 MB 6ES7954-8LE02-0AA0
10 digital outputs (relays),
2 analog inputs; 24 MB 6ES7954-8LF02-0AA0
Expandable with up to
256 MB 6ES7954-8LL02-0AA0
3 communication modules,
8 signal modules and 1 signal 2 GB 6ES7954-8LP01-0AA0
board/communication board;
Digital inputs can be used as HSC Extension cable 6ES7290-6AA30-0XA0
at 100 kHz for two-tier configuration
SB 1221 signal board For connecting digital/analog
signal modules;
4 inputs, 5 V DC, 200 kHz 6ES7221-3AD30-0XB0 2 m long
4 inputs, 24 V DC, 200 kHz 6ES7221-3BD30-0XB0 Terminal block (spare part)
SB 1222 signal board for CPU 1214C
4 outputs, 5 V DC, 0.1 A, 200 kHz 6ES7222-1AD30-0XB0 For DI, with 20 screws, tin-plated; 6ES7292-1AV30-0XA0
4 units
4 outputs, 24 V DC, 0.1 A, 200 kHz 6ES7222-1BD30-0XB0
For DO, with 12 screws, tin-plated; 6ES7292-1AM30-0XA0
4 units
For AI, with 3 screws, tin-plated; 6ES7292-1BC30-0XA0
4 units
RJ45 cable grip 6ES7290-3AA30-0XA0
4 items per pack
Single port
Front flap set (spare part) 6ES7291-1AB30-0XA0
for CPU 1214C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1214C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1215C
■ Overview
• The compact high-performance CPU
• With 24 integral input/outputs
• Expandable by:
2 - 1 signal board (SB) or communication board (CB)
- 8 signal modules (SM)
- Max. 3 communication modules (CM)
■ Technical specifications
6ES7215-1BG40-0XB0 6ES7215-1AG40-0XB0 6ES7215-1HG40-0XB0
CPU 1215C AC/DC/Relay CPU 1215C DC/DC/DC CPU 1215C DC/DC/Relay
General information
Engineering with
• Programming package STEP 7 V13 or higher STEP 7 V13 or higher STEP 7 V13 or higher
Supply voltage
24 V DC Yes Yes
120 V AC Yes
230 V AC Yes
Power losses
Power loss, typ. 14 W 12 W 12 W
Memory
Work memory
• integrated 100 kbyte 100 kbyte 100 kbyte
Load memory
• integrated 4 Mbyte 4 Mbyte 4 Mbyte
• plug-in (SIMATIC Memory Card), 2 Gbyte; with SIMATIC memory card 2 Gbyte; with SIMATIC memory card 2 Gbyte; with SIMATIC memory card
max.
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.085 µs; / Operation 0.085 µs; / Operation 0.085 µs; / Operation
for word operations, typ. 1.7 µs; / Operation 1.7 µs; / Operation 1.7 µs; / Operation
for floating point arithmetic, typ. 2.3 µs; / Operation 2.3 µs; / Operation 2.3 µs; / Operation
Data areas and their retentivity
Flag
• Number, max. 8 kbyte; 8 kbyte; 8 kbyte;
Size of bit memory address area Size of bit memory address area Size of bit memory address area
Address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
Digital inputs
Number of digital inputs 14; integrated 14; integrated 14; integrated
• of which, inputs usable 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
for technological functions
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1215C
2
Number of digital outputs 10; Relays 10 10; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Integrated channels (AI) 2; 0 to 10 V 2; 0 to 10 V 2; 0 to 10 V
Input ranges
• Voltage Yes Yes Yes
Analog outputs
Integrated channels (AO) 2; 0 to 20 mA 2; 0 to 20 mA 2; 0 to 20 mA
1st interface
Interface type PROFINET PROFINET PROFINET
Functionality
• PROFINET IO Device Yes Yes Yes
• PROFINET IO Controller Yes Yes Yes
Communication functions
S7 communication
• supported Yes Yes Yes
Open IE communication
• TCP/IP Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
Integrated Functions
Number of counters 6 6 6
Counter frequency (counter) max. 100 kHz 100 kHz 100 kHz
Frequency meter Yes Yes Yes
Controlled positioning Yes Yes Yes
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4 4 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Operating temperature
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 130 mm 130 mm 130 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 585 g 520 g 550 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1215C
2
100 KB, load memory 4 MB; 2 transistor outputs 24 V DC,
Wide-range AC power supply 0.5 A, 5 W;
85 ... 264 V AC; Can be used as HSC at
Boolean execution times 0.085 s up to 30 kHz
per operation;
14 digital inputs, 2 inputs, 5 V DC, 200 kHz 6ES7223-3AD30-0XB0
10 digital outputs (relays), 2 outputs, 5 V DC, 0.1 A, 200 kHz
2 analog inputs, 2 inputs, 24 V DC, 200 kHz 6ES7223-3BD30-0XB0
2 analog outputs; 2 outputs, 24 V DC, 0.1 A, 200 kHz
Expandable with up to
3 communication modules, SB 1231 signal board 6ES7231-4HA30-0XB0
8 signal modules and 1 signal
1 analog input, ±10 V with 12 bits or
board/communication board;
0 ... 20 mA with 11 bits
Digital inputs can be used as HSC
at 100 kHz Thermocouple signal board 6ES7231-5QA30-0XB0
SB 1231
Compact CPU, DC/DC/DC; 6ES7215-1AG40-0XB0
Integrated program/data memory 1 input +/- 80 mV,
100 KB, load memory 4 MB; resolution 15 bits + sign,
Supply voltage 24 V DC; thermocouples type J, K
Boolean execution times 0.085 s
per operation; RTD signal board SB 1231 6ES7231-5PA30-0XB0
14 digital inputs, 10 digital outputs, 1 input for resistance temperature
2 analog inputs, 2 analog outputs; sensors Pt 100, Pt 200, Pt 500,
Expandable with up to Pt 1000, resolution 15 bits + sign
3 communication modules,
8 signal modules and 1 signal SB 1232 signal board 6ES7232-4HA30-0XB0
board/communication board;
Digital inputs can be used as HSC 1 analog output, ±10 V with 12 bits
at 100 kHz, or 0 to 20 mA with 11 bits
24 V DC digital outputs can be Communication board CB 1241 6ES7241-1CH30-1XB0
used as pulse outputs (PTO) RS485
or as outputs with pulse width
modulation (PWM) for point-to-point connection,
at 100 kHz with 1 RS485 interface
Compact CPU, DC/DC/relay; 6ES7215-1HG40-0XB0 BB 1297 battery board 6ES7297-0AX30-0XA0
Integrated program/data memory for long-term backup
100 KB, load memory 4 MB; of real time clock;
Supply voltage 24 V DC; can be plugged into the signal
Boolean execution times 0.085 s board slot of an S7-1200 CPU
per operation; in FW version 3.0 or higher;
14 digital inputs, Battery (CR 1025) not included
10 digital outputs (relays),
2 analog inputs, Simulator (optional) 6ES7274-1XH30-0XA0
2 analog outputs;
Expandable with up to 14 input switches, for CPU 1214C
3 communication modules, SIMATIC Memory Card (optional)
8 signal modules and 1 signal
board/communication board; 4 MB 6ES7954-8LC02-0AA0
Digital inputs can be used as HSC
12 MB 6ES7954-8LE02-0AA0
at 100 kHz
SB 1221 signal board 24 MB 6ES7954-8LF02-0AA0
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1215C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1217C
■ Overview 6ES7217-1AG40-0XB0
CPU 1217C DC/DC/DC
• The compact high-performance CPU
Analog inputs
• With 24 integrated I/Os Integrated channels (AI) 2; 0 to 10 V
• Expandable by: Input ranges
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1217C
2
data memory of 125 KB,
load memory of 4 MB; Communication board CB 1241 6ES7241-1CH30-1XB0
Supply voltage 24 V DC; RS485
Boolean execution times 0.085 s for point-to-point connection,
per operation; with 1 RS485 interface
14 digital inputs
(10 digital 24 V DC inputs, BB 1297 battery board 6ES7297-0AX30-0XA0
4 digital 1.5 V DC differential inputs),
for long-term backup
10 digital outputs
of real time clock;
(6 digital 24 V DC outputs, 4 digital
can be plugged into the signal
1.5 V DC differential outputs),
board slot of an S7-1200 CPU
2 analog inputs, 2 analog outputs;
in FW version 3.0 or higher;
Expandable with up to
Battery (CR 1025) not included
3 communication modules,
8 signal modules and 1 signal Simulator (optional)
board/communication board;
Digital inputs can be used digital, 14 input switches, 6ES7274-1XK30-0XA0
as HSC at 1 MHz, for CPU 1217C
24 V DC digital outputs can analog, 2 potentiometer inputs 6ES7274-1XA30-0XA0
be used as pulse outputs (PTO)
or outputs with pulse width SIMATIC Memory Card (optional)
modulation (PWM)
at 100 kHz 4 MB 6ES7954-8LC02-0AA0
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1200
CPU 1217C
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
• Entry-level CPU in the S7-1500 controller product range • The CPU for applications with medium requirements for
• Suitable for applications with medium requirements for program/data storage in the S7-1500 controller product range
program scope and processing speed • Medium to high processing speed for binary and floating-
• Used as central controller in production lines with central and point arithmetic
distributed I/O • Used as central controller in production lines with central and
• PROFINET IO IRT interface with 2-port switch distributed I/O
• PROFINET IO Controller for operating distributed I/O on • PROFINET IO IRT interface with 2-port switch
PROFINET • PROFINET IO Controller for operating distributed I/O on
• PROFINET I-Device for connecting the CPU as an intelligent PROFINET
PROFINET device under a SIMATIC or non-Siemens • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET I/O controller PROFINET device under a SIMATIC or non-Siemens
• Isochronous mode PROFINET I/O controller
• Integrated Motion Control functionalities for controlling speed- • Isochronous mode
controlled and positioning axes, support for external encoders • Integrated Motion Control functionalities for controlling speed-
• Integrated web server with the option of creating user-defined controlled and positioning axes, support for external encoders
web pages • Integrated web server with the option of creating user-defined
• SIMATIC memory card required for operation of the CPU web pages
• SIMATIC memory card required for operation of the CPU
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
■ Technical specifications
6ES7511-1AK00-0AB0 6ES7513-1AL00-0AB0 6ES7515-2AM00-0AB0
CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN
General information
Engineering with
• STEP 7 TIA Portal can be V13 V13 V13 2
configured/integrated as of version
Display
Screen diagonal (cm) 3.45 cm 3.45 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC
Power losses
Power loss, typ. 5.7 W 5.7 W 6.3 W
Memory
Work memory
• integrated (for program) 150 kbyte 300 kbyte 500 kbyte
• integrated (for data) 1 Mbyte 1.5 Mbyte 3 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte 32 Gbyte
max.
CPU processing times
for bit operations, typ. 60 ns 40 ns 30 ns
for word operations, typ. 72 ns 48 ns 36 ns
for fixed point arithmetic, typ. 96 ns 64 ns 48 ns
for floating point arithmetic, typ. 384 ns 256 ns 192 ns
Counters, timers
and their retentivity
S7 counter
• Number 2 048 2 048 2 048
IEC counter
• Number Any Any Any
(only limited by the main memory) (only limited by the main memory) (only limited by the main memory)
S7 times
• Number 2 048 2 048 2 048
IEC timer
• Number Any Any Any
(only limited by the main memory) (only limited by the main memory) (only limited by the main memory)
Data areas and their retentivity
Flag
• Number, max. 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; 32 kbyte; 32 kbyte;
All inputs are in the process image All inputs are in the process image All inputs are in the process image
• Outputs 32 kbyte; 32 kbyte; 32 kbyte;
All outputs are in the process image All outputs are in the process image All outputs are in the process image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
2
1st interface
• Interface types
- Number of ports 2 2 2
- Integrated switch Yes Yes Yes
- RJ 45 (Ethernet) Yes Yes Yes
• Protocols
- PROFINET IO Controller Yes Yes Yes
- PROFINET IO Device Yes Yes Yes
- SIMATIC communication Yes Yes Yes
- Open IE communication Yes Yes Yes
- Web server Yes Yes Yes
- Media redundancy Yes Yes Yes
2nd interface
• Interface types
- Number of ports 1
- Integrated switch No
- RJ 45 (Ethernet) Yes
• Protocols
- PROFINET IO Controller No
- PROFINET IO Device No
- SIMATIC communication Yes
- Open IE communication Yes
- Web server Yes
Protocols
Number of connections
• Number of connections, max. 96 128 192;
via integrated interfaces of the CPU
and connected CPs / CMs
PROFINET IO Controller
• Services
- Max. number of connectable IO 128 128 256
devices for RT
- Number of IO Devices with IRT 64 64 64
and the option "high performance",
max.
Isochronous mode
Isochronous operation (application Yes Yes Yes
synchronized up to terminal)
Supported technology objects
Motion Yes Yes Yes
• Speed-controlled axis
- Number of speed-controlled axes, 6; Up to 6 axes in total 6; Up to 6 axes in total 20; Up to 20 axes in total
max. (speed-controlled, positioning axis, (speed-controlled, positioning axis, (speed-controlled, positioning axis,
external encoders) are supported external encoders) are supported external encoders) are supported
• Positioning axis
- Number of positioning axes, 6; Up to 6 axes in total 6; Up to 6 axes in total 20; Up to 20 axes in total
max. (speed-controlled, positioning axis, (speed-controlled, positioning axis, (speed-controlled, positioning axis,
external encoders) are supported external encoders) are supported external encoders) are supported
• External encoders
- Number of external encoders, 6; Up to 6 axes in total 6; Up to 6 axes in total 20; Up to 20 axes in total
max. (speed-controlled, positioning axis, (speed-controlled, positioning axis, (speed-controlled, positioning axis,
external encoders) are supported external encoders) are supported external encoders) are supported
Controller
• PID_Compact Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller
with integrated optimization with integrated optimization with integrated optimization
• PID_3Step Yes; PID controller Yes; PID controller Yes; PID controller
with integrated optimization for valves with integrated optimization for valves with integrated optimization for valves
Counting and measuring
• High-speed counter Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
2
Operating temperature
• horizontal installation, min. 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C; 60 °C; 60 °C;
Display: 50 °C, at an operating Display: 50 °C, at an operating Display: 50 °C, at an operating
temperature of typically 50 °C, temperature of typically 50 °C, temperature of typically 50 °C,
the display is switched off the display is switched off the display is switched off
• vertical installation, min. 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C; 40 °C; 40 °C;
Display: 40 °C, at an operating Display: 40 °C, at an operating Display: 40 °C, at an operating
temperature of typically 40 °C, temperature of typically 40 °C, temperature of typically 40 °C,
the display is switched off the display is switched off the display is switched off
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- GRAPH Yes; from STEP 7 V12 SP1 Yes; from STEP 7 V12 SP1 Yes
Know-how protection
• User program protection Yes Yes Yes
• Copy protection Yes Yes Yes
• Block protection Yes Yes Yes
Access protection
• Password for display Yes Yes Yes
• Protection level: Write protection Yes Yes Yes
• Protection level: Yes Yes Yes
Read/write protection
• Protection level: Yes Yes Yes
Complete protection
Dimensions
Width 35 mm 35 mm 70 mm
Height 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm
Weights
Weight, approx. 430 g 430 g 830 g
6ES7516-3AN00-0AB0 6ES7518-4AP00-0AB0
CPU 1516-3 PN/DP CPU 1518-4 PN/DP
General information
Engineering with
• STEP 7 TIA Portal can be V13 V13
configured/integrated as of version
Display
Screen diagonal (cm) 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC
Power losses
Power loss, typ. 7W 24 W
Memory
Work memory
• integrated (for program) 1 Mbyte 3 Mbyte
• integrated (for data) 5 Mbyte 10 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte
max.
CPU processing times
for bit operations, typ. 10 ns 1 ns
for word operations, typ. 12 ns 2 ns
for fixed point arithmetic, typ. 16 ns 2 ns
for floating point arithmetic, typ. 64 ns 6 ns
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
2
and their retentivity
S7 counter
• Number 2 048 2 048
IEC counter
• Number Any (only limited by the main memory) Any (only limited by the main memory)
S7 times
• Number 2 048 2 048
IEC timer
• Number Any (only limited by the main memory) Any (only limited by the main memory)
Data areas and their retentivity
Flag
• Number, max. 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the process image 32 kbyte; All inputs are in the process image
• Outputs 32 kbyte; All outputs are in the process image 32 kbyte; All outputs are in the process image
Time of day
Clock
• Type Hardware clock Hardware clock
Interfaces
1st interface
• Interface types
- Number of ports 2 2
- Integrated switch Yes Yes
- RJ 45 (Ethernet) Yes Yes
• Protocols
- PROFINET IO Controller Yes Yes
- PROFINET IO Device Yes Yes
- SIMATIC communication Yes Yes
- Open IE communication Yes Yes
- Web server Yes Yes
- Media redundancy Yes Yes
2nd interface
• Interface types
- Number of ports 1 1
- Integrated switch No No
- RJ 45 (Ethernet) Yes Yes
• Protocols
- PROFINET IO Controller No No
- PROFINET IO Device No No
- SIMATIC communication Yes Yes
- Open IE communication Yes Yes
- Web server Yes Yes
3rd interface
• Interface types
- Number of ports 1 1
- Integrated switch No
- RJ 45 (Ethernet) Yes
- RS 485 Yes
• Protocols
- PROFINET IO Controller No
- PROFINET IO Device No
- SIMATIC communication Yes Yes
- Open IE communication Yes
- Web server Yes
- PROFIBUS DP master Yes
- PROFIBUS DP slave No
4th interface
• Interface types
- Number of ports 1
- RS 485 Yes
• Protocols
- SIMATIC communication Yes
- PROFIBUS DP master Yes
- PROFIBUS DP slave No
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
2
Number of connections
• Number of connections, max. 256 384; via integrated interfaces of the CPU
and connected CPs / CMs
PROFINET IO Controller
• Services
- Max. number of connectable 256 512
IO devices for RT
- Number of IO Devices with IRT 64 64
and the option "high performance",
max.
PROFIBUS
• Services
- Number of DP slaves 125; 125;
In total, up to 768 distributed I/O devices can be connected In total, up to 768 distributed I/O devices can be connected
via PROFIBUS or PROFINET via PROFIBUS or PROFINET
Isochronous mode
Isochronous operation (application Yes Yes
synchronized up to terminal)
Supported technology objects
Motion Yes Yes
• Speed-controlled axis
- Number of speed-controlled axes, 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
max. axis, external encoders) are supported axis, external encoders) are supported
• Positioning axis
- Number of positioning axes, 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
max. axis, external encoders) are supported axis, external encoders) are supported
• External encoders
- Number of external encoders, 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
max. axis, external encoders) are supported axis, external encoders) are supported
Controller
• PID_Compact Yes; Universal PID controller with integrated optimization Yes; Universal PID controller with integrated optimization
• PID_3Step Yes; PID controller with integrated optimization for valves Yes; PID controller with integrated optimization for valves
Counting and measuring
• High-speed counter Yes Yes
Ambient conditions
Operating temperature
• horizontal installation, min. 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature 60 °C; Display: 50 °C, at an operating temperature
of typically 50 °C, the display is switched off of typically 50 °C, the display is switched off
• vertical installation, min. 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature 40 °C; Display: 40 °C, at an operating temperature
of typically 40 °C, the display is switched off of typically 40 °C, the display is switched off
Configuration
programming
• Programming language
- LAD Yes Yes
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- GRAPH Yes; STEP 7 V12 SP1 or higher Yes
Know-how protection
• User program protection Yes Yes
• Copy protection Yes Yes
• Block protection Yes Yes
Access protection
• Password for display Yes Yes
• Protection level: Write protection Yes Yes
• Protection level: Yes Yes
Read/write protection
• Protection level: Yes Yes
Complete protection
Dimensions
Width 70 mm 175 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 845 g 1 988 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Standard CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Fail-safe CPUs
■ Technical specifications
6ES7516-3FN00-0AB0 6ES7518-4FP00-0AB0
CPU 1516F-3 PN/DP CPU 1518F-4PN/DP
General information
Engineering with
• STEP 7 TIA Portal can be V13 V13
configured/integrated as of version
Display
Screen diagonal (cm) 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC
Power losses
Power loss, typ. 7W 24 W
Memory
Work memory
• integrated (for program) 1.5 Mbyte 4.5 Mbyte
• integrated (for data) 5 Mbyte 10 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte
max.
CPU processing times
for bit operations, typ. 10 ns 1 ns
for word operations, typ. 12 ns 2 ns
for fixed point arithmetic, typ. 16 ns 2 ns
for floating point arithmetic, typ. 64 ns 6 ns
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Fail-safe CPUs
2
and their retentivity
S7 counter
• Number 2 048 2 048
IEC counter
• Number Any (only limited by the main memory) Any (only limited by the main memory)
S7 times
• Number 2 048 2 048
IEC timer
• Number Any (only limited by the main memory) Any (only limited by the main memory)
Data areas and their retentivity
Flag
• Number, max. 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the process image 32 kbyte; All inputs are in the process image
• Outputs 32 kbyte; All outputs are in the process image 32 kbyte; All outputs are in the process image
Time of day
Clock
• Type Hardware clock Hardware clock
Interfaces
1st interface
• Interface types
- Number of ports 2 2
- Integrated switch Yes Yes
- RJ 45 (Ethernet) Yes Yes
• Protocols
- PROFINET IO Controller Yes Yes
- PROFINET IO Device Yes Yes
- SIMATIC communication Yes Yes
- Open IE communication Yes Yes
- Web server Yes Yes
- Media redundancy Yes Yes
2nd interface
• Interface types
- Number of ports 1 1
- Integrated switch No No
- RJ 45 (Ethernet) Yes Yes
• Protocols
- PROFINET IO Controller No No
- PROFINET IO Device No No
- SIMATIC communication Yes Yes
- Open IE communication Yes Yes
- Web server Yes Yes
3rd interface
• Interface types
- Number of ports 1 1
- Integrated switch No
- RJ 45 (Ethernet) Yes
- RS 485 Yes
• Protocols
- PROFINET IO Controller No
- PROFINET IO Device No
- SIMATIC communication Yes Yes
- Open IE communication Yes
- Web server Yes
- PROFIBUS DP master Yes
- PROFIBUS DP slave No
4th interface
• Interface types
- Number of ports 1
- RS 485 Yes
• Protocols
- SIMATIC communication Yes
- PROFIBUS DP master Yes
- PROFIBUS DP slave No
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Fail-safe CPUs
2
Number of connections
• Number of connections, max. 256; via integrated interfaces of the CPU and 384; via integrated interfaces of the CPU and
connected CPs / CMs connected CPs / CMs
PROFINET IO Controller
• Services
- Max. number of connectable 256 512
IO devices for RT
- Number of IO Devices with IRT 64 64
and the option "high performance",
max.
PROFIBUS
• Services
- Number of DP slaves 125; In total, up to 768 distributed I/O devices can be 125; In total, up to 768 distributed I/O devices can be
connected via CPs/CMs via PROFIBUS or PROFINET connected via CPs/CMs via PROFIBUS or PROFINET
Isochronous mode
Isochronous operation (application Yes Yes
synchronized up to terminal)
supported technology objects
Motion Yes Yes
• Speed-controlled axis
- Number of speed-controlled axes, 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
max. axis, external encoders) are supported axis, external encoders) are supported
• Positioning axis
- Number of positioning axes, max. 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
axis, external encoders) are supported axis, external encoders) are supported
• External encoders
- Number of external encoders, 20; Up to 20 axes in total (speed-controlled, positioning 128; Up to 128 axes in total (speed-controlled, positioning
max. axis, external encoders) are supported axis, external encoders) are supported
Controller
• PID_Compact Yes; Universal PID controller with integrated optimization Yes; Universal PID controller with integrated optimization
• PID_3Step Yes; PID controller with integrated optimization for valves Yes; PID controller with integrated optimization for valves
Counting and measuring
• High-speed counter Yes Yes
Ambient conditions
Operating temperature
• horizontal installation, min. 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature 60 °C; Display: 50 °C, at an operating temperature
of typically 50 °C, the display is switched off of typically 50 °C, the display is switched off
• vertical installation, min. 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature 40 °C; Display: 40 °C, at an operating temperature
of typically 40 °C, the display is switched off of typically 40 °C, the display is switched off
Configuration
programming
• Programming language
- LAD Yes; incl. Failsafe Yes; incl. Failsafe
- FBD Yes; incl. Failsafe Yes; incl. Failsafe
- STL Yes Yes
- SCL Yes Yes
- GRAPH Yes Yes
Know-how protection
• User program protection Yes Yes
• Copy protection Yes Yes
• Block protection Yes Yes
Access protection
• Password for display Yes Yes
• Protection level: Write protection Yes Yes
• Protection level: Yes Yes
Read/write protection
• Protection level: Yes Yes
Complete protection
Dimensions
Width 70 mm 175 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 845 g 1 988 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Fail-safe CPUs
2
PROFINET IO IRT interface, Sold by the meter,
PROFINET/PROFIBUS interface; max. length 1 000 m,
SIMATIC memory card required minimum order quantity 20 m
CPU 1518F-4 PN/DP 6ES7518-4FP00-0AB0 PROFIBUS FC Robust Cable 6XV1830-0JH10
Fail-safe CPU, 4.5 MB RAM for 2-wire, shielded;
program, 10 MB for data, Sold by the meter,
PROFINET IO IRT interface, max. length 1 000 m,
2 PROFINET interfaces, minimum order quantity 20 m
PROFIBUS interface;
SIMATIC Memory Card required PROFIBUS FC Flexible Cable 6XV1831-2K
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-1500
Fail-safe CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
• The CPU with mid-range program memory and quantity • The CPU with a large program memory and quantity
frameworks framework for demanding applications
• High processing power in binary and floating-point arithmetic • For cross-industry automation tasks in series machine, special
• Used as central controller in production lines with central and machine and plant construction
distributed I/O • Used as central controller in production lines with central and
• PROFINET interface with 2-port switch distributed I/O
• PROFINET IO Controller for operating distributed I/O on • High processing power in binary and floating-point arithmetic
PROFINET • PROFINET interface with 2-port switch
• PROFINET I-Device for connecting the CPU as intelligent • PROFINET I/O Controller for operating distributed I/O on
PROFINET device under a SIMATIC or third-party PROFINET
PROFINET I/O Controller • PROFINET I-Device for connecting the CPU as intelligent
• Component Based Automation (CBA) on PROFINET PROFINET device under a SIMATIC or third-party
• PROFINET proxy for intelligent devices on PROFIBUS DP in PROFINET I/O Controller
Component Based Automation (CBA) • Distributed intelligence in Component Based Automation
• Integrated web server with the option of creating user-defined (CBA) on PROFINET
web pages • PROFINET proxy for intelligent devices on PROFIBUS DP in
• Combined MPI/PROFIBUS DP master/slave interface Component Based Automation (CBA)
• Isochronous mode on PROFIBUS and PROFINET • Integrated web server with the option of creating user-defined
web pages
SIMATIC Micro Memory Card required for operation of CPU. • Combined MPI/PROFIBUS DP master/slave interface
• Isochronous mode on PROFIBUS and PROFINET
• Optionally supports the use of SIMATIC engineering tools
SIMATIC Micro Memory Card required for operation of CPU.
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
2
• For cross-industry automation tasks in series machine, special
machine and plant construction
• Used as central controller in production lines with central and
distributed I/O on PROFIBUS and PROFINET
• PROFINET I/O controller for operating distributed I/O on
PROFINET
• PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
PROFINET I/O controller
• PROFINET interface with 2-port switch
• Isochronous mode on PROFIBUS or PROFINET
• Integrated web server with the option of creating user-defined
web pages
• Distributed intelligence in Component Based Automation
(CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP in
Component Based Automation (CBA)
• Optionally supports the use of SIMATIC engineering tools
SIMATIC Micro Memory Card required for operation of the CPU.
■ Technical specifications
6ES7315-2EH14-0AB0 6ES7317-2EK14-0AB0 6ES7318-3EL01-0AB0
CPU 315-2 PN/DP CPU 317-2 PN/DP CPU 319-3 PN/DP
General information
Engineering with
• Programming package STEP7 V 5.5 or higher STEP7 V 5.5 or higher STEP7 V 5.5 or higher
Supply voltage
24 V DC Yes Yes Yes
Power losses
Power loss, typ. 4.65 W 4.65 W 14 W
Memory
Work memory
• integrated 384 kbyte 1 024 kbyte 2 048 kbyte
• Size of retentive memory for retentive 128 kbyte 256 kbyte 700 kbyte
data blocks
Load memory
• pluggable (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs 0.004 µs
for word operations, typ. 0.09 µs 0.03 µs 0.01 µs
for fixed point arithmetic, typ. 0.12 µs 0.04 µs 0.01 µs
for floating point arithmetic, typ. 0.45 µs 0.16 µs 0.04 µs
Counters, timers and their retentiv-
ity
S7 counter
• Number 256 512 2 048
IEC counter
• present Yes Yes Yes
S7 times
• Number 256 512 2 048
IEC timer
• present Yes Yes Yes
Data areas and their retentivity
Flag
• Number, max. 2 048 byte 4 096 byte 8 192 byte
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
2
I/O address area
• Inputs 2 048 byte 8 192 byte 8 192 byte
• Outputs 2 048 byte 8 192 byte 8 192 byte
Process image
• Inputs, adjustable 2 048 byte 8 192 byte 8 192 byte
• Outputs, adjustable 2 048 byte 8 192 byte 8 192 byte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
Operating hours counter
• Number 1 4 4
1st interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Physics RS 485 RS 485 RS 485
Functionality
• MPI Yes Yes Yes
• DP master Yes Yes Yes
• DP slave Yes Yes Yes; A DP slave at both interfaces
simultaneously is not possible
• Point-to-point connection No No No
DP master
• Number of DP slaves, max. 124 124 124
2nd interface
Interface type PROFINET PROFINET Integrated RS 485 interface
Physics Ethernet RJ45 Ethernet RJ45 RS 485
Number of ports 2 2
Functionality
• MPI No No No
• DP master No No Yes
• DP slave No No Yes; A DP slave at both interfaces
simultaneously is not possible
• PROFINET IO Controller Yes; Also simultaneously Yes; Also simultaneously No
with IO-Device functionality with IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously Yes; Also simultaneously No
with IO Controller functionality with IO Controller functionality
• PROFINET CBA Yes Yes No
DP master
• Number of DP slaves, max. 124
PROFINET IO Controller
• Max. number of connectable 128 128
IO devices for RT
• Number of IO devices with 128 128
IRT and the option "high flexibility"
• Number of IO Devices with 64 64
IRT and the option
"high performance", max.
3rd interface
Interface type PROFINET
Physics Ethernet RJ45
Number of ports 2
Functionality
• MPI No
• DP master No
• DP slave No
• PROFINET IO Controller Yes; Also simultaneously
with I-Device functionality
• PROFINET IO Device Yes; Also simultaneously
with IO Controller functionality
• PROFINET CBA Yes
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
2
• Max. number of connectable 256
IO devices for RT
• Number of IO devices with 256
IRT and the option "high flexibility"
• Number of IO Devices with 64
IRT and the option
• "high performance", max.
Isochronous mode
Isochronous operation (application Yes; Via PROFIBUS DP or PROFINET Yes; Via PROFIBUS DP or PROFINET Yes; Via 2nd PROFIBUS DP or
synchronized up to terminal) interface interface PROFINET interface
Communication functions
PG/OP communication Yes Yes Yes
Data record routing Yes Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
• supported Yes Yes Yes
S5-compatible communication
• supported Yes; Via CP and loadable FC Yes; Via CP and loadable FC Yes; Via CP and loadable FC
Open IE communication
• TCP/IP Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
• ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
• UDP Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
Web server
• supported Yes Yes Yes
Number of connections
• overall 16 32 32
Ambient conditions
Operating temperature
• min. 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C
Configuration
Programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 40 mm 40 mm 120 mm
Height 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm
Weights
Weight, approx. 340 g 340 g 1 250 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
2
combined MPI/PROFIBUS DP and the three subsequent updates
master/slave interface,
Ethernet/PROFINET interface with Power supply connector 6ES7391-1AA00-0AA0
2-port switch; 10 units, spare part
MMC required
SIMATIC S7 training case 6ES7910-3AA00-0XA0
CPU 317-2 PN/DP 6ES7317-2EK14-0AB0
With mounting components
1 MB main memory, for mounting S7-200 and S7-300
24 V DC power supply,
combined MPI/PROFIBUS DP USB A2 PC adapter 6GK1571-0BA00-0AA0
master/slave interface,
for connecting a PG/PC or
Ethernet/PROFINET interface with
Notebook to PROFIBUS or MPI;
2-port switch;
USB cable included in scope of
MMC required
delivery
CPU 319-3 PN/DP 6ES7318-3EL01-0AB0
PROFIBUS bus components
Main memory 2 MB,
PROFIBUS DP bus connector
power supply 24 V DC,
RS 485
combined MPI/PROFIBUS DP
master/slave interface, • with 90° cable outlet, max. transfer
PROFIBUS DP master/slave rate 12 Mbit/s
interface, - without PG interface 6ES7972-0BA12-0XA0
Ethernet/PROFINET interface with - with PG interface 6ES7972-0BB12-0XA0
2-port switch; • with 90° cable outlet for
MMC required FastConnect connection system,
SIMATIC Micro Memory Card max. transfer rate 12 Mbit/s
- without PG interface, 1 unit 6ES7972-0BA52-0XA0
64 KB 6ES7953-8LF30-0AA0
- without PG interface, 100 units 6ES7972-0BA52-0XB0
128 KB 6ES7953-8LG30-0AA0 - with PG interface, 1 unit 6ES7972-0BB52-0XA0
512 KB 6ES7953-8LJ30-0AA0 - with PG interface, 100 units 6ES7972-0BB52-0XB0
• with axial cable outlet for 6GK1500-0EA02
2 MB 6ES7953-8LL31-0AA0 SIMATIC OP, for connecting to
4 MB 6ES7953-8LM31-0AA0 PPI, MPI, PROFIBUS
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Standard CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Compact CPUs
2
arithmetic
• For connecting distributed I/O via PROFIBUS and PROFINET
• Combined MPI/PROFIBUS DP master/slave interface
• PROFINET interface with 2-port switch
• PROFINET IO Controller for operating distributed I/O on
PROFINET
• PROFINET I-Device for connecting the CPU as intelligent
PROFINET device under a SIMATIC or third-party PROFINET
I/O controller
• Component based Automation (CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP in
Component based Automation (CBA)
• Integrated Web server with the option of creating user-defined
web pages
• Isochronous mode on PROFINET
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
CPU 314C-2 PN/DP 6ES7314-6EH04-0AB0 CPU 314C-2 PN/DP 6ES7314-6EH04-0AB0
General information Time of day
Hardware product version 01 Clock
Firmware version V3.3 • Hardware clock (real-time clock) Yes
Supply voltage Operating hours counter
24 V DC Yes • Number 1
Power losses Digital inputs
Power loss, typ. 14 W integrated channels (DI) 24
Memory Digital outputs
Work memory integrated channels (DO) 16
• integrated 192 kbyte Analog inputs
• expandable No Integrated channels (AI) 5; 4 x current/voltage, 1 x resistance
• Size of retentive memory for retentive 64 kbyte
data blocks Input ranges
• Voltage Yes;
Load memory ±10 V / 100 k; 0 V to 10 V / 100 k
• pluggable (MMC), max. 8 Mbyte • Current Yes;
CPU processing times ±20 mA / 100 ; 0 mA to 20 mA /
for bit operations, typ. 0.06 µs 100 ; 4 mA to 20 mA / 100
• Resistance thermometer Yes;
for word operations, typ. 0.12 µs Pt 100 / 10 M
for fixed point arithmetic, typ. 0.16 µs • Resistance Yes;
0 to 600 / 10 M
for floating point arithmetic, typ. 0.59 µs
Analog outputs
Counters, timers and their retentivity Integrated channels (AO) 2
S7 counter
• Number 256 Output ranges, voltage
• 0 to 10 V Yes
IEC counter • -10 to +10 V Yes
• present Yes
Output ranges, current
S7 times • 0 to 20 mA Yes
• Number 256 • -20 to +20 mA Yes
IEC timer • 4 to 20 mA Yes
• present Yes 1st interface
Data areas and their retentivity Interface type Integrated RS 485 interface
Flag Physics RS 485
• Number, max. 256 byte Functionality
Address area • MPI Yes
I/O address area • DP master Yes
• Inputs 2 048 byte • DP slave Yes
• Outputs 2 048 byte • Point-to-point connection No
Process image DP master
• Inputs, adjustable 2 048 byte • Number of DP slaves, max. 124
• Outputs, adjustable 2 048 byte
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Compact CPUs
2
manual
Physics Ethernet RJ45
Counter frequency (counter) max. 60 kHz
Number of ports 2
Frequency measurement Yes
Functionality
• MPI No Number of frequency meters 4; up to 60 kHz (see "Technological
• DP master No Functions" manual)
• DP slave No Controlled positioning Yes
• PROFINET IO Controller Yes; Also simultaneously Integrated function blocks Yes; PID controller (see "Technologi-
with IO-Device functionality (closed-loop control) cal Functions" manual)
• PROFINET IO Device Yes; Also simultaneously
with IO Controller functionality PID controller Yes
• PROFINET CBA Yes Number of pulse outputs 4; Pulse width modulation up to
PROFINET IO Controller 2.5 kHz (see "Technological Func-
tions" Manual)
• Number of connectable IO devices, 128
max. Limit frequency (pulse) 2.5 kHz
• Max. number of connectable 128 Ambient conditions
IO devices for RT
Operating temperature
• Number of IO devices with IRT and 128
the option "high flexibility" • Min. 0 °C
• Number of IO Devices with IRT and 64 • max. 60 °C
the option "high performance", max. Configuration
Isochronous mode Configuration software
Isochronous operation (application Yes; For PROFINET only • STEP 7 Yes; V5.5 or higher
synchronized up to terminal) programming
Communication functions - LAD Yes
PG/OP communication Yes - FBD Yes
Data record routing Yes - STL Yes
- SCL Yes
Global data communication - CFC Yes
• supported Yes - GRAPH Yes
S7 basic communication - HiGraph® Yes
• supported Yes Know-how protection
S7 communication • User program protection/password Yes
• supported Yes protection
• Block encryption Yes; With S7 block Privacy
S5-compatible communication
• supported Yes; Via CP and loadable FC Dimensions
Width 120 mm
Open IE communication
• TCP/IP Yes; Via integrated PROFINET inter- Height 125 mm
face and loadable FBs Depth 130 mm
- Number of connections, max. 8
• ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET inter- Weights
face and loadable FBs Weight, approx. 730 g
- Number of connections, max. 8
• UDP Yes; Via integrated PROFINET inter-
face and loadable FBs
- Number of connections, max. 8
Web server
• supported Yes
Number of connections
• overall 12
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Compact CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
• Complies with safety requirements to SIL 3 acc. to IEC 61508
■ Overview CPU 315F-2 PN/DP and PL e acc. to ISO 13849.1
• Fail-safe I/O modules in distributed stations can be connected
through the integrated PROFINET interface (PROFIsafe) and/
or through the integrated PROFIBUS DP interface (PROFIsafe)
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
■ Technical specifications
6ES7315-2FJ14-0AB0 6ES7317-2FK14-0AB0 6ES7318-3FL01-0AB0
CPU 315F-2 PN/DP CPU 317F-2 PN/DP CPU 319F-3 PN/DP
General information
Engineering with
• Programming package STEP 7 V 5.5 or higher, STEP 7 V 5.5 or higher, STEP 7 V 5.5 or higher, 2
Distributed Safety V 5.4 SP4 Distributed Safety V 5.4 SP4 Distributed Safety V 5.4 SP4
Supply voltage
24 V DC Yes Yes Yes
Power losses
Power loss, typ. 4.65 W 4.65 W 14 W
Memory
Work memory
• integrated 512 kbyte 1 536 kbyte 2 560 kbyte
• Size of retentive memory 128 kbyte 256 kbyte 700 kbyte
for retentive data blocks
Load memory
• pluggable (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs 0.004 µs
for word operations, typ. 0.09 µs 0.03 µs 0.01 µs
for fixed point arithmetic, typ. 0.12 µs 0.04 µs 0.01 µs
for floating point arithmetic, typ. 0.45 µs 0.16 µs 0.04 µs
Counters, timers
and their retentivity
S7 counter
• Number 256 512 2 048
IEC counter
• present Yes Yes Yes
S7 times
• Number 256 512 2 048
IEC timer
• present Yes Yes Yes
Data areas and their retentivity
Flag
• Number, max. 2 048 byte 4 096 byte 8 192 byte
Address area
I/O address area
• Inputs 2 048 byte 8 192 byte 8 192 byte
• Outputs 2 048 byte 8 192 byte 8 192 byte
Process image
• Inputs, adjustable 2 048 byte 8 192 byte 8 192 byte
• Outputs, adjustable 2 048 byte 8 192 byte 8 192 byte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
Operating hours counter
• Number 1 4 4
1st interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Physics RS 485 RS 485 RS 485
Functionality
• MPI Yes Yes Yes
• DP master Yes Yes Yes
• DP slave Yes Yes Yes; A DP slave at both interfaces
simultaneously is not possible
• Point-to-point connection No No No
DP master
• Number of DP slaves, max. 124 124 124
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
2
Interface type PROFINET PROFINET Integrated RS 485 interface
Physics Ethernet RJ45 Ethernet RJ45 RS 485
Number of ports 2 2
Functionality
• MPI No No No
• DP master No No Yes
• DP slave No No Yes; A DP slave at both interfaces
simultaneously is not possible
• PROFINET IO Controller Yes; Also simultaneously Yes; Also simultaneously No
with IO-Device functionality with IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously Yes; Also simultaneously No
with IO Controller functionality with IO Controller functionality
• PROFINET CBA Yes Yes No
DP master
• Number of DP slaves, max. 124
PROFINET IO Controller
• Max. number of connectable 128 128
IO devices for RT
• Number of IO devices with IRT and 128 128
the option "high flexibility"
• Number of IO Devices with IRT and 64 64
the option "high performance", max.
3rd interface
Interface type PROFINET
Physics Ethernet RJ45
Number of ports 2
Functionality
• MPI No
• DP master No
• DP slave No
• PROFINET IO Controller Yes; Also simultaneously
with I-Device functionality
• PROFINET IO Device Yes; Also simultaneously
with IO Controller functionality
• PROFINET CBA Yes
PROFINET IO Controller
• Max. number of connectable 256
IO devices for RT
• Number of IO devices with IRT and 256
the option "high flexibility"
• Number of IO Devices with IRT and 64
the option "high performance", max.
Isochronous mode
Isochronous operation (application Yes; Via PROFIBUS DP or Yes; Via PROFIBUS DP or Yes; Via 2nd PROFIBUS DP or
synchronized up to terminal) PROFINET interface PROFINET interface PROFINET interface
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
2
PG/OP communication Yes Yes Yes
Data record routing Yes Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
• supported Yes Yes Yes
S5-compatible communication
• supported Yes; Via CP and loadable FC Yes; Via CP and loadable FC Yes; Via CP and loadable FC
Open IE communication
• TCP/IP Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
• ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
• UDP Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface Yes; Via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
Web server
• supported Yes; only read function Yes Yes
Number of connections
• overall 16 32 32
Ambient conditions
Operating temperature
• min. 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C
Configuration
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 40 mm 40 mm 120 mm
Height 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm
Weights
Weight, approx. 340 g 340 g 1 250 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-300
Fail-safe CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Standard CPUs
• The low-cost starter solution for the medium performance • High-performance CPUs in the high-end performance range
range • Applicable for plants with high requirements in the high-end
• Can be used in small and medium-sized systems with require- performance range
ments of the medium performance range • Integrated PROFINET functions in CPU 416-3 PN/DP
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Standard CPUs
■ Technical specifications
6ES7412-2EK06-0AB0 6ES7414-3EM06-0AB0 6ES7416-3ES06-0AB0
CPU 412-2 PN CPU 414-3 PN/DP CPU 416-3 PN/DP
General information
Engineering with
• Programming package STEP 7 V 5.5 or higher / STEP 7 V 5.5 or higher / STEP 7 V 5.5 or higher / 2
IMap V3.0 or higher IMap V3.0 or higher IMap V3.0 or higher
+ iMap-STEP 7 Addon V3.0 SP5 + iMap-STEP 7 Addon V3.0 SP5 + iMap-STEP 7 Addon V3.0 SP5
Supply voltage
24 V DC No; Power supply via system power No; Power supply via system power No; Power supply via system power
supply supply supply
Power losses
Power loss, typ. 5.5 W 6.5 W 6.5 W
Memory
Work memory
• integrated 1 Mbyte 4 Mbyte 16 Mbyte
• integrated (for program) 0.5 Mbyte 2 Mbyte 8 Mbyte
• integrated (for data) 0.5 Mbyte 2 Mbyte 8 Mbyte
Load memory
• expandable FEPROM, max. 64 Mbyte 64 Mbyte 64 Mbyte
• integrated RAM, max. 512 kbyte 512 kbyte 1 Mbyte
• expandable RAM, max. 64 Mbyte 64 Mbyte 64 Mbyte
CPU processing times
for bit operations, typ. 75 ns 45 ns 30 ns
for word operations, typ. 75 ns 45 ns 30 ns
for fixed point arithmetic, typ. 75 ns 45 ns 30 ns
for floating point arithmetic, typ. 225 ns 135 ns 90 ns
Counters, timers and their retentivity
S7 counter
• Number 2 048 2 048 2 048
IEC counter
• present Yes Yes Yes
S7 times
• Number 2 048 2 048 2 048
IEC timer
• present Yes Yes Yes
Data areas and their retentivity
Flag
• Number, max. 4 kbyte; Size of bit memory address 8 kbyte; Size of bit memory address 16 kbyte; Size of bit memory address
area area area
Address area
I/O address area
• Inputs 4 kbyte 8 kbyte 16 kbyte
• Outputs 4 kbyte 8 kbyte 16 kbyte
Process image
• Inputs, adjustable 4 kbyte 8 kbyte 16 kbyte
• Outputs, adjustable 4 kbyte 8 kbyte 16 kbyte
Hardware configuration
Slots
• Required slots 1 2 2
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes
Operating hours counter
• Number 16 16 16
1st interface
Interface type integrated integrated integrated
Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI
Functionality
• MPI Yes Yes Yes
• DP master Yes Yes Yes
• DP slave Yes Yes Yes
DP master
• Number of DP slaves, max. 32 32 32
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Standard CPUs
2
Interface type PROFINET PROFINET PROFINET
Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45
Number of ports 2 2 2
Functionality
• DP master No No No
• DP slave No No No
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• PROFINET CBA Yes Yes Yes
DP master
• Number of DP slaves, max.
PROFINET IO Controller
• Max. number of connectable 256 256 256
IO devices for RT
• Number of IO devices with IRT and 256 256 256
the option "high flexibility"
• Number of IO Devices with IRT and 64 64 64
the option "high performance", max.
3rd interface
Interface type Pluggable interface module (IF) Pluggable interface module (IF)
DP master
• Number of DP slaves, max. 96 125
Isochronous mode
Isochronous operation (application Yes; Via PROFIBUS DP or PROFINET Yes; Via PROFIBUS DP or PROFINET Yes; Via PROFIBUS DP or PROFINET
synchronized up to terminal) interface interface interface
Communication functions
PG/OP communication Yes Yes Yes
Data record routing Yes Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
• supported Yes Yes Yes
S5-compatible communication
• supported Yes; Via FC AG_SEND and AG_RECV, Yes; Via FC AG_SEND and AG_RECV, Yes; Via FC AG_SEND and AG_RECV,
max. via 10 CP 443-1 or 443-5 max. via 10 CP 443-1 or 443-5 max. via 10 CP 443-1 or 443-5
Standard communication (FMS)
• supported Yes; Via CP and loadable FB Yes; Via CP and loadable FB Yes; Via CP and loadable FB
Open IE communication
• TCP/IP Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter-
face and loadable FBs face and loadable FBs face and loadable FBs
- Number of connections, max. 46 62 94
• ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter-
face or CP 443-1 Adv. and loadable face or CP 443-1 Adv. and loadable face or CP 443-1 and loadable FBs
FBs FBs
- Number of connections, max. 46 62 94
• UDP Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter- Yes; Via integrated PROFINET inter-
face and loadable FBs face and loadable FBs face and loadable FBs
- Number of connections, max. 46 62 94
Web server
• supported Yes Yes Yes
Number of connections
• overall 48 64 96
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Standard CPUs
2
programming
• Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 25 mm 50 mm 50 mm
Height 290 mm 290 mm 290 mm
Depth 219 mm 219 mm 219 mm
Weights
Weight, approx. 750 g 900 g 900 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Standard CPUs
2 Without PG interface
With PG interface
6ES7972-0BA12-0XA0
6ES7972-0BB12-0XA0
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible;
RS 485 bus connector with UL approval;
with angled cable outlet Sold by the meter
Max. transfer rate 12 Mbit/s FO Standard Cable GP (50/125) 6XV1873-2A
■ More information
Brochures
Information material for downloading can be found
in the Internet:
http://www.automation.siemens.com/infocenter
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Fail-safe CPUs
• For constructing a fail-safe automation system for plants with • For constructing a fail-safe automation system for plants with
increased safety requirements increased safety requirements
• CPUs for high demands in the mid-level performance range • High-performance CPU in the top-end performance range
• Applicable for plants with additional demands on • Complies with safety requirements to SIL 3 acc. to IEC 61508
programming scope and processing speed and PL e acc. to ISO 13849.1
• Complies with safety requirements to SIL 3 acc. to IEC 61508 • Standard and safety-related tasks can be performed with a
and PL e acc. to ISO 13849.1 single CPU
• Standard and safety-related tasks can be performed with a • Multi-processor mode is possible
single CPU • Safety-related communication with distributed I/O devices
• Integrated PROFINET functions in CPU 414F-3 PN/DP over PROFIBUS DP with the PROFIsafe profile
• Multi-processor mode is possible • Fail-safe I/O modules can be connected decentralized over
• Safety-related communication with distributed I/O devices the integrated interfaces (DP and PN with CPU416F-3 PN/DP)
over PROFIBUS DP or PROFINET IO with PROFIsafe profile and/or through communication modules (CP443-5 Ext. and
CP443-1 Adv.)
• Fail-safe I/O modules can be connected in a distributed
manner via the integrated interfaces (DP and PN with • Standard modules for non-safety-related applications can be
CPU 416F-3 PN/DP) and/or through communication modules operated centrally and decentralized
(CP 443-5 Extended and CP 443-1 Adv.)
• Central and distributed use of standard modules for non-
safety-oriented applications
■ Technical specifications
6ES7414-3FM06-0AB0 6ES7416-3FS06-0AB0
CPU 414F-3 PN/DP CPU 416F-3 PN/DP
General information
Engineering with
• Programming package STEP 7 V 5.5 or higher / IMap V3.0 or higher STEP 7 V 5.5 or higher / IMap V3.0 or higher
+ iMap- STEP 7 Addon V3.0 SP5 + iMap- STEP 7 Addon V3.0 SP5
Supply voltage
24 V DC No; Power supply via system power supply No; Power supply via system power supply
Power losses
Power loss, typ. 6.5 W 6.5 W
Memory
Work memory
• integrated 4 Mbyte 16 Mbyte
• integrated (for program) 2 Mbyte 8 Mbyte
• integrated (for data) 2 Mbyte 8 Mbyte
Load memory
• expandable FEPROM, max. 64 Mbyte 64 Mbyte
• integrated RAM, max. 512 kbyte 1 Mbyte
• expandable RAM, max. 64 Mbyte 64 Mbyte
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Fail-safe CPUs
2
for bit operations, typ. 45 ns 30 ns
for word operations, typ. 45 ns 30 ns
for fixed point arithmetic, typ. 45 ns 30 ns
for floating point arithmetic, typ. 135 ns 90 ns
Counters, timers
and their retentivity
S7 counter
• Number 2 048 2 048
IEC counter
• present Yes Yes
S7 times
• Number 2 048 2 048
IEC timer
• present Yes Yes
Data areas and their retentivity
Flag
• Number, max. 8 kbyte; Size of bit memory address area 16 kbyte; Size of bit memory address area
Address area
I/O address area
• Inputs 8 kbyte 16 kbyte
• Outputs 8 kbyte 16 kbyte
Process image
• Inputs, adjustable 8 kbyte 16 kbyte
• Outputs, adjustable 8 kbyte 16 kbyte
Hardware configuration
Slots
• Required slots 2 2
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes
Operating hours counter
• Number 16 16
1st interface
Interface type integrated integrated
Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI
Functionality
• MPI Yes Yes
• DP master Yes Yes
• DP slave Yes Yes
DP master
• Number of DP slaves, max. 32 32
2nd interface
Interface type PROFINET PROFINET
Physics Ethernet RJ45 Ethernet RJ45
Number of ports 2 2
Functionality
• DP master No No
• DP slave No No
• PROFINET IO Controller Yes Yes
• PROFINET IO Device Yes Yes
• PROFINET CBA Yes Yes
DP master
• Number of DP slaves, max.
PROFINET IO Controller
• Max. number of connectable 256 256
IO devices for RT
• Number of IO devices with IRT and 256 256
the option "high flexibility"
• Number of IO Devices with IRT and 64 64
the option "high performance", max.
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Fail-safe CPUs
2
Interface type Pluggable interface module (IF) Pluggable interface module (IF)
Plug-in interface modules IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)
Physics RS 485 / PROFIBUS RS 485 / PROFIBUS
Functionality
• MPI No No
• DP master Yes Yes
• DP slave Yes Yes
DP master
• Number of DP slaves, max. 96 125
Isochronous mode
Isochronous operation (application Yes; Via PROFIBUS DP or PROFINET interface Yes; Via PROFIBUS DP or PROFINET interface
synchronized up to terminal)
Communication functions
PG/OP communication Yes Yes
Data record routing Yes Yes
Global data communication
• supported Yes Yes
S7 basic communication
• supported Yes Yes
S7 communication
• supported Yes Yes
S5-compatible communication
• supported Yes; Via FC AG_SEND and AG_RECV, Yes; Via FC AG_SEND and AG_RECV,
max. via 10 CP 443-1 or 443-5 max. via 10 CP 443-1 or 443-5
Standard communication (FMS)
• supported Yes; Via CP and loadable FB Yes; Via CP and loadable FB
Open IE communication
• TCP/IP Yes; Yes;
via integrated PROFINET interface and loadable FBs via integrated PROFINET interface and loadable FBs
- Number of connections, max. 62 94
• ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET interface or CP 443-1 Adv. Yes; Via integrated PROFINET interface or CP 443-1 and
and loadable FBs loadable FBs
- Number of connections, max. 62 94
• UDP Yes; Yes;
via integrated PROFINET interface and loadable FBs via integrated PROFINET interface and loadable FBs
- Number of connections, max. 62 94
Web server
• supported Yes Yes
Number of connections
• overall 64 96
Configuration
programming
• Programming language
- LAD Yes Yes
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- CFC Yes Yes
- GRAPH Yes Yes
- HiGraph® Yes Yes
Know-how protection
• User program protection/password Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 50 mm 50 mm
Height 290 mm 290 mm
Depth 219 mm 219 mm
Weights
Weight, approx. 900 g 900 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Fail-safe CPUs
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
Fail-safe CPUs
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
• CPU for SIMATIC S7-400H and S7-400F/FH • CPU for SIMATIC S7-400H and S7-400F/FH
• Can be used in S7-400H high-availability systems • Can be used in S7-400H high-availability systems
• Can be used with F runtime license as F-capable CPU • Can be used with F runtime license as F-capable CPU
in S7-400F/FH safety-related systems in S7-400F/FH safety-related systems
• With integrated PROFIBUS DP master and combined • With integrated PROFIBUS DP master and combined
MPI/PROFIBUS DP master interface MPI/PROFIBUS DP master interface
• With integrated PROFINET interface (2-port switch) • With integrated PROFINET interface (2-port switch)
• Features 2 slots for sync modules • Features 2 slots for sync modules
• CPU for SIMATIC S7-400H and S7-400F/FH • CPU for SIMATIC S7-400H and S7-400F/FH
• Can be used in S7-400H high-availability systems • Can be used in S7-400H high-availability systems
• Can be used with F runtime license as F-capable CPU • Can be used with F runtime license as F-capable CPU
in S7-400F/FH safety-related systems in S7-400F/FH safety-related systems
• With integrated PROFIBUS DP master and combined • With integrated PROFIBUS DP master interface and
MPI/PROFIBUS DP master interface combined MPI/PROFIBUS DP master interface
• With integrated PROFINET interface (2-port switch) • With integrated PROFINET interface (2-port switch)
• Features 2 slots for sync modules • Features 2 slots for sync modules
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
■ Technical specifications
6ES7412-5HK06-0AB0 6ES7414-5HM06-0AB0 6ES7416-5HS06-0AB0 6ES7417-5HT06-0AB0
CPU 412-5H PN/DP CPU 414-5H PN/DP CPU 416-5H PN/DP CPU 417-5H PN/DP
General information
Engineering with
• Programming package STEP 7 V 5.5 SP2 or higher STEP 7 V 5.5 SP2 or higher STEP 7 V 5.5 SP2 or higher STEP 7 V 5.5 SP2 or higher 2
with HF1 with HF1 with HF1 with HF1
Supply voltage
24 V DC No; Power supply No; Power supply No; Power supply No; Power supply
Via system power supply Via system power supply Via system power supply Via system power supply
Power losses
Power loss, typ. 7.5 W 7.5 W 7.5 W 7.5 W
Memory
Work memory
• integrated 1 Mbyte 4 Mbyte 16 Mbyte 32 Mbyte
• integrated (for program) 512 kbyte 2 Mbyte 6 Mbyte 16 Mbyte
• integrated (for data) 512 kbyte 2 Mbyte 10 Mbyte 16 Mbyte
Load memory
• expandable FEPROM, max. 64 Mbyte 64 Mbyte 64 Mbyte 64 Mbyte
• integrated RAM, max. 512 kbyte 512 kbyte 1 Mbyte 1 Mbyte
• expandable RAM, max. 64 Mbyte 64 Mbyte 64 Mbyte 64 Mbyte
CPU processing times
for bit operations, typ. 31.25 ns 18.75 ns 12.5 ns 7.5 ns
for word operations, typ. 31.25 ns 18.75 ns 12.5 ns 7.5 ns
for fixed point arithmetic, typ. 31.25 ns 18.75 ns 12.5 ns 7.5 ns
for floating point arithmetic, typ. 62.5 ns 37.5 ns 25 ns 15 ns
Counters, timers
and their retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048
IEC counter
• present Yes Yes Yes Yes
S7 times
• Number 2 048 2 048 2 048 2 048
IEC timer
• present Yes Yes Yes Yes
Data areas and their retentivity
Flag
• Number, max. 8 192 byte 8 192 byte 16 384 byte 16 384 byte
Address area
I/O address area
• Inputs 8 kbyte 8 kbyte 16 kbyte 16 kbyte
• Outputs 8 kbyte 8 kbyte 16 kbyte 16 kbyte
Process image
• Inputs, adjustable 8 kbyte 8 kbyte 16 kbyte 16 kbyte
• Outputs, adjustable 8 kbyte 8 kbyte 16 kbyte 16 kbyte
Hardware configuration
Slots
• Required slots 2 2 2 2
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes Yes Yes
Operating hours counter
• Number 16 16 16 16
1st interface
Interface type integrated integrated integrated integrated
Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI
Functionality
• MPI Yes Yes Yes Yes
• DP master Yes Yes Yes Yes
• DP slave No No No No
DP master
• Number of DP slaves, max. 32 32 32 32
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
2
Interface type PROFINET PROFINET PROFINET PROFINET
Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45
Number of ports 2 2 2 2
Functionality
• DP master No No No No
• DP slave No No No No
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device No No No No
• PROFINET CBA No No No No
PROFINET IO Controller
• Max. number of connectable 256 256 256 256
IO devices for RT
3rd interface
Interface type integrated integrated integrated integrated
Physics RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS
Functionality
• DP master Yes Yes Yes Yes
• DP slave No No No No
DP master
• Number of DP slaves, max. 64 96 125 125
4th interface
Interface type Pluggable synchronization Pluggable synchronization Pluggable synchronization Pluggable synchronization
submodule (FO) submodule (FO) submodule (FO) submodule (FO)
Plug-in interface modules Synchronization modules Synchronization modules Synchronization modules Synchronization modules
6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or
6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0
5. Interface
Interface type Pluggable synchronization Pluggable synchronization Pluggable synchronization Pluggable synchronization
submodule (FO) submodule (FO) submodule (FO) submodule (FO)
Plug-in interface modules Synchronization modules Synchronization modules Synchronization modules Synchronization modules
6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or 6ES7960-1AA06-0XA0 or
6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0 6ES7960-1AB06-0XA0
Isochronous mode
Isochronous operation (application No No No No
synchronized up to terminal)
Communication functions
PG/OP communication Yes Yes Yes Yes
Data record routing Yes Yes Yes Yes
S7 routing Yes Yes Yes Yes
Global data communication
• supported No No No No
S7 basic communication
• supported No No No No
S7 communication
• supported Yes Yes Yes Yes
S5-compatible communication
• supported Yes; (via CP max. 10 and Yes; (via CP max. 10 and Yes; (via CP max. 10 and Yes; (via CP max. 10 and
FC AG_SEND and FC AG_SEND and FC AG_SEND and FC AG_SEND and
FC AG_RECV) FC AG_RECV) FC AG_RECV) FC AG_RECV)
Standard communication (FMS)
• supported Yes; Yes; Yes; Yes;
Via CP and loadable FB Via CP and loadable FB Via CP and loadable FB Via CP and loadable FB
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
2
• TCP/IP Yes; Yes; Yes; Yes;
Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET
interface and loadable FBs interface and loadable FBs interface and loadable FBs interface and loadable FBs
- Number of connections, max. 46 62 94 118
• ISO-on-TCP (RFC1006) Yes; Yes; Yes; Yes;
Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET
interface or CP 443-1 and interface or CP 443-1 and interface or CP 443-1 and interface or CP 443-1 and
loadable FBs loadable FBs loadable FBs loadable FBs
- Number of connections, max. 46 62 94 118
• UDP Yes; Yes; Yes; Yes;
Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET Via integrated PROFINET
interface and loadable FBs interface and loadable FBs interface and loadable FBs interface and loadable FBs
- Number of connections, max. 46 62 94 118
Web server
• supported No No No No
Number of connections
• overall 48 64 96 120
Configuration
programming
• Programming language
- LAD Yes Yes Yes Yes
- FBD Yes Yes Yes Yes
- STL Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- CFC Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes
- HiGraph® Yes Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 50 mm 50 mm 50 mm 50 mm
Height 290 mm 290 mm 290 mm 290 mm
Depth 219 mm 219 mm 219 mm 219 mm
Weights
Weight, approx. 995 g 995 g 995 g 995 g
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
2
1 combined MPI/PROFIBUS DP 1 combined MPI/PROFIBUS DP
master interface, master interface,
1 PROFIBUS DP interface, 1 PROFIBUS DP interface,
2 PROFINET interfaces (switches), 2 PROFINET interfaces (switches),
2 slots for sync modules, 2 slots for sync modules,
slot for memory card, slot for memory card,
incl. slot number labels incl. slot number labels
CPU 412-5H system bundle CPU 417-5H system bundle
Not assembled, consisting of: Not assembled, consisting of:
UR2-H rack, UR2-H rack,
2 x PS 405/407 power supply units, 2 x PS 405/407 power supply units,
2 x CPU 412-5H, 2 x CPU 417-5H,
4 x Sync modules (for max. 10 m), 4 x Sync modules (for max. 10 m),
2 x fiber optic cables for 2 x fiber optic cables
sync modules (1 m), for sync modules (1 m),
4 x backup batteries; 4 x backup batteries;
additional two memory cards additional two memory cards
required (to be ordered separately) required (to be ordered separately)
CPU 412-5H system bundle, 6ES7400-0HR01-4AB0 CPU 417-5H system bundle, 6ES7400-0HR04-4AB0
120/230 V AC, 10 A 120/230 V AC, 10 A
CPU 412-5H system bundle, 6ES7400-0HR51-4AB0 CPU 417-5H system bundle, 6ES7400-0HR54-4AB0
24/48/60 V DC, 10 A 24/48/60 V DC, 10 A
CPU 414-5H 6ES7414-5HM06-0AB0 Memory card RAM
For S7-400H and S7-400F/FH; 1 MB 6ES7952-1AK00-0AA0
4 MB RAM,
1 combined MPI/PROFIBUS DP 2 MB 6ES7952-1AL00-0AA0
master interface, 4 MB 6ES7952-1AM00-0AA0
1 PROFIBUS DP interface,
2 PROFINET interfaces (switches), 8 MB 6ES7952-1AP00-0AA0
2 slots for sync modules,
16 MB 6ES7952-1AS00-0AA0
slot for memory card,
incl. slot number labels 64 MB 6ES7952-1AY00-0AA0
CPU 414-5H system bundle FEPROM memory card
Not assembled, consisting of: 1 MB 6ES7952-1KK00-0AA0
UR2-H rack,
2 x PS 405/407 power supply units, 2 MB 6ES7952-1KL00-0AA0
2 x CPU 414-5H, 4 MB 6ES7952-1KM00-0AA0
4 x Sync modules (for max. 10 m),
2 x fiber optic cables 8 MB 6ES7952-1KP00-0AA0
for sync modules (1 m),
4 x backup batteries; 16 MB 6ES7952-1KS00-0AA0
additional two memory cards 32 MB 6ES7952-1KT00-0AA0
required (to be ordered separately)
64 MB 6ES7952-1KY00-0AA0
CPU 414-5H system bundle, 6ES7400-0HR02-4AB0
120/230 V AC, 10 A MPI cable 6ES7901-0BF00-0AA0
CPU 414-5H system bundle, 6ES7400-0HR52-4AB0 for connection of SIMATIC S7
24/48/60 V DC, 10 A and PG via MPI;
5 m in length
CPU 416-5H 6ES7416-5HS06-0AB0
Slot number plates 6ES7912-0AA00-0AA0
For S7-400H and S7-400F/FH;
16 MB RAM, 1 set (spare part)
1 combined MPI/PROFIBUS DP S7 F Systems RT License 6ES7833-1CC00-6YX0
master interface,
1 PROFIBUS DP interface, For processing safety-related user
2 PROFINET interfaces (switches), programs, for one S7-400H-based
2 slots for sync modules, system each with CPU 412-5H,
slot for memory card, CPU 414-5H, CPU 416-5H or
incl. slot number labels CPU 417-5H
CPU 416-5H system bundle S7 F Systems V6.1 6ES7833-1CC02-0YA5
Not assembled, consisting of: Programming and configuring
UR2-H rack, environment for creating and
2 x PS 405/407 power supply units, operating safety-related STEP 7
2 x CPU 416-5H, programs for an S7-400H-based
4 x Sync modules (for max. 10 m), target system,
2 x fiber optic cables floating license for 1 user,
for sync modules (1 m), runs under Windows XP Prof SP2,
4 x backup batteries; Windows XP Prof SP2/SP3,
additional two memory cards Windows Server 2003 SP2
required (to be ordered separately) 2 languages (English, German)
Type of delivery:
CPU 416-5H system bundle, 6ES7400-0HR03-4AB0 Certificate of License
120/230 V AC, 10 A as well as software and electronic
CPU 416-5H system bundle, 6ES7400-0HR53-4AB0 documentation on CD
24/48/60 V DC, 10 A
PROFINET/Industrial Ethernet
Controllers / Modular controllers / SIMATIC S7-400
High-availability CPUs
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
New with WinAC RTX 2010 SP1:
■ Overview • SIMATIC IPC427D and IPC477D are fully supported
- Communication via onboard CP 5622
- Retentive memory
- LED display of the operating status
■ Benefits
• Hard real time and maximum performance
• Implementation of fast, S7-compatible control solutions with
low processor loading.
Alongside the control task, sufficient processor capability is
available for processing complex, demanding PC applica-
tions in parallel.
■ Technical specifications
6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010 SIMATIC WinAC RTX 2010
General information Nesting depth
Firmware version V4.6 • per priority class 24
Memory • additional within an error OB 24
Type of memory RAM Counters, timers
and their retentivity
Work memory
S7 counter
• integrated (for program) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool • Number 2 048
• integrated (for data) 4 Mbyte; Adjustable; depends on • Retentivity
Non Paged Memory Pool - adjustable Yes
- lower limit 0
Load memory
- upper limit 2 047
• integrated RAM, max. 8 Mbyte; Adjustable; depends on
Non Paged Memory Pool - preset 8
• Counting range
CPU processing times - adjustable Yes
for bit operations, typ. 0.004 µs - lower limit 0
for fixed point arithmetic, typ. 0.003 µs - upper limit 999
for floating point arithmetic, typ. 0.004 µs IEC counter
• present Yes
Reference platform Pentium IV, 2.4 GHz
• Type SFB
CPU-blocks • Number Unlimited
DB (limited only by RAM capacity)
• Number, max. 65 535
S7 times
• Size, max. 64 kbyte
• Number 2 048
FB • Retentivity
• Number, max. 65 536 - adjustable Yes
• Size, max. 64 kbyte - lower limit 0
FC - upper limit 2 047
• Number, max. 65 536; • Time range
Limited only by RAM set for code - lower limit 10 ms
- upper limit 9 990 s
OB
• Size, max. 64 kbyte IEC timer
• Number of free cycle OBs 1 • present Yes
• Number of time alarm OBs 1 • Type SFB
• Number of delay alarm OBs 1 • Number Unlimited
• Number of time interrupt OBs 9 (limited only by RAM capacity)
• Number of process alarm OBs 1
• Number of ODK OBs 3; OB 52-54
• Number of DPV1 alarm OBs 3; OB 55-57
• Number isochronous mode OBs 2; OB 61-62
• Number of startup OBs 2
• Number of asynchronous error OBs 7
• Number of synchronous error OBs 2
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
2
Retentivity without UPS 128 KB with SIMATIC IPC227D, Clock
and PS Extension Board IPC427C, IPC427D, HMI IPC277D, • Hardware clock (real-time clock) Yes
IPC477C, IPC477D; • battery-backed and synchronizable Yes
further SIMATIC IPCs on request
Operating hours counter
Retentivity with UPS all data
• Number 8
Flag
Clock synchronization
• Number, max. 16 kbyte
• supported Yes
• of which retentive MB 0 to MB 16383
• to PC-CP, slave Yes
• Retentivity preset MB 0 to MB 15
• on Ethernet via NTP Yes
• Number of clock memories 8
Interfaces
Data blocks
• Number, max. Limited only by available retentive Number of USB interfaces 0
memory (NVRAM, or file storage) 1st interface
• Size, max. 64 kbyte Interface type CP 5611, CP 5611-A2, CP 5612,
• Retentivity adjustable Yes; via non-retain property on DB CP 5621, CP 5622,
• Retentivity preset Yes integrated PROFIBUS interface
of the SIMATIC PC
Local data
Max. no. of simultaneously 1
• adjustable, max. 64 kbyte operable CPs
• preset 32 kbyte
• per priority class, max. 61 440 byte Physics RS 485 / PROFIBUS
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
2
Interface type CP 5613, CP 5613-A2, CP 5603, • Transmission rate, min. 100 Mbit/s
CP 5623 • Transmission rate, max. 100 Mbit/s
Max. no. of simultaneously 4 • Max. number of connectable 128
operable CPs IO devices for RT
- of which in line, max. 128
Physics RS 485 / PROFIBUS
• IRT, supported No
Isolated Yes • Prioritized startup supported Yes
Functionality - Number of IO Devices, max. 32
• MPI No • Activation/deactivation Yes
• DP master Yes of IO Devices
• DP slave No - Maximum number of IO devices 8
that can be activated/deactivated
DP master at the same time.
• Number of connections, max. 50 • IO Devices changing during opera- Yes
• Transmission rate, max. 12 Mbit/s tion (partner ports), supported
• Number of DP slaves, max. 125 • Device replacement without swap Yes
• Services medium
- PG/OP communication Yes • Send cycles 1 ms
- Routing Yes • Updating time 1 - 512 ms (minimum value depends
on communication share set for
- Global data communication No
PROFINET I/O, on the number of
- S7 basic communication No I/O devices, and on the volume of
- S7 communication Yes configured user data)
- S7 communication, as client Yes • Services
- S7 communication, as server Yes - PG/OP communication Yes
- Equidistance mode support Yes; Only in conjunction with - Routing Yes; S7 routing
isochronous mode - S7 communication Yes
- Isochronous mode Yes - Isochronous mode No
- SYNC/FREEZE Yes - Open IE communication Yes
- Activation/deactivation of DP Yes • Address area
slaves
- Inputs, max. 16 kbyte
- Direct data exchange (slave-to- Yes
- Outputs, max. 16 kbyte
slave communication)
- User data per address area, max. 2 kbyte
- DPV0 Yes
- User data consistency, max. 254 byte
- DPV1 Yes
• Address area PROFINET CBA
- Inputs, max. 16 kbyte • acyclic transmission Yes
- Outputs, max. 16 kbyte • Cyclic transmission Yes
• User data per DP slave SIMATIC communication
- Inputs, max. 244 byte • PG/OP communication Yes
- Outputs, max. 244 byte • S7 routing Yes
3rd interface • S7 communication Yes
Interface type PROFINET • Number of connections, max. 16
Max. no. of simultaneously 1; Intel Pro/1000 (82573L, 82574L, Open IE communication
operable CPs 82541PI; non-shared IRQ required); • Open IE communication, supported Yes
integrated IE interface SIMATIC PC • Number of connections, max. 32
4x7B, 6x7B, 8x7B, IPC4x7C, • Local port numbers used 0, 20, 21, 23, 25, 80, 102, 135, 161,
IPC6x7C, IPC8x7C, IPC2x7D, at the system end 443, 8080, 34962, 34963, 34964,
IPC4x7D 65532, 65533, 65534, 65535
Physics Ethernet • Keep-alive function, supported Yes
Isolated Yes 4th interface
Integrated switch No Interface type PROFINET
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
2
• supported Yes PG/OP communication Yes
• Switchover time on line break, 200 ms Data record routing Yes; Only with CP 5611 or integrated
typically PROFIBUS interface of the
• Number of stations in the ring, max. 50 SIMATIC PC
Functionality Global data communication
• PROFINET IO Controller Yes • supported No
• PROFINET IO Device No
S7 basic communication
• PROFINET CBA Yes
• supported No
• Open IE communication Yes
• Web server Yes S7 communication
• supported Yes
PROFINET IO Controller
• as server Yes
• Transmission rate, max. 100 Mbit/s
• As client Yes
• Max. number of connectable 256
IO devices for RT • User data per job, max. 64 kbyte;
When using BSEND/USEND
- of which in line, max. 256
• Number of IO devices with IRT and 64 Open IE communication
the option "high flexibility" • TCP/IP Yes
- of which in line, max. 32 - Number of connections, max. 32
• Number of IO Devices with IRT and 64 - Data length for connection type Not supported
the option "high performance", max. 01H, max.
- of which in line, max. 32 - Data length for connection type 65 534 byte
• IRT, supported Yes 11H, max.
• Prioritized startup supported Yes - Data length, max. 65 534 byte
- Number of IO Devices, max. 32 • ISO-on-TCP (RFC1006) Yes
• Activation/deactivation of Yes - Number of connections, max. 32
IO Devices - Data length, max. 65 534 byte
- Maximum number of IO devices 8 • UDP Yes
that can be activated/deactivated - Number of connections, max. 32
at the same time. - Data length, max. 1 472 byte
• IO Devices changing during opera- Yes
tion (partner ports), supported Web server
• Device replacement Yes • supported Yes
without swap medium • Number of HTTP clients 2
• Send cycles 250 µs, 500 µs, 1 ms • User-defined websites No
• Updating time 0.25...512 depending on the send PROFINET CBA
cycle (at set setpoint communication load)
• Services • Setpoint for the CPU 20 %
- PG/OP communication Yes communication load
- Routing Yes; S7 routing • Number of remote 64
- S7 communication Yes interconnection partners
- Isochronous mode Yes • Number of functions, master/slave 30
- Open IE communication Yes • Total of all Master/Slave 1 000
• Address area connections
- Inputs, max. 16 kbyte • Data length of all incoming 6 800 byte
- Outputs, max. 16 kbyte connections master/slave, max.
- User data per address area, max. 2 kbyte • Data length of all outgoing 6 800 byte
connections master/slave, max.
- User data consistency, max. 254 byte
• Number of device-internal and 500
SIMATIC communication PROFIBUS interconnections
• PG/OP communication Yes • Data length of device-internal and 4 000 byte
• S7 routing Yes PROFIBUS interconnections, max.
• S7 communication Yes • Data length per connection, max. 1 400 byte
• Number of connections, max. 32 • Remote interconnections
with acyclic transmission
Open IE communication
- Sampling frequency: 500 ms
• Open IE communication, supported Yes Sampling time, min.
• Number of connections, max. 32 - Number of incoming 100
• Local port numbers used 0, 20, 21, 25, 80, 102, 135, 161, interconnections
at the system end 34962, 34963, 34964, 65532, 65533, - Number of outgoing 100
65534, 65535 interconnections
Isochronous mode - Data length of all incoming 2 000 byte
Isochronous operation (application Yes interconnections, max.
synchronized up to terminal) - Data length of all outgoing 2 000 byte
interconnections, max.
Number of DP masters with 2
- Data length per connection, max. 1 400 byte
isochronous mode
User data per isochronous slave, 128 byte
max.
equidistance Yes
shortest clock pulse 2.2 ms;
2.2 ms without partial process image;
2.2 ms with partial process image
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
2
with cyclic transmission Windows CE No
- Transmission frequency: 10 ms
Transmission interval, min. Windows NT 4.0 No
- Number of incoming 200 Windows 2000 No
interconnections
Windows XP Yes; Professional, SP2 and SP3
- Number of outgoing 200
interconnections Windows XP embedded Yes; With the delivery image of the
- Data length of all incoming 4 800 byte SIMATIC PC
interconnections, max. • Supported HAL types under ACPI uniprocessor PC,
- Data length of all outgoing 4 800 byte Windows XP ACPI multiprocessor PC,
interconnections, max. MPS multiprocessor PC
- Data length per connection, max. 250 byte Windows Vista No
• HMI variables via PROFINET
(acyclic) Windows 7 Yes; Professional, Enterprise,
Ultimate (only 32 bits)
- Number of stations that can log on 3
for HMI variables (PN OPC/iMap) Windows embedded Standard 7 Yes; With the delivery image of the
- HMI variable updating 500 ms SIMATIC PC
- Number of HMI variables 200 Configuration
- Data length of all HMI variables, 2 000 byte Configuration software
max. • STEP 7 Yes; V5.5 and higher, Engineering
• PROFIBUS proxy functionality Tools (optional)
- supported Yes
programming
- Number of linked PROFIBUS 16
devices • Nesting levels 8
- Data length per connection, max. 240 byte; Slave-dependent • Programming language
- LAD Yes
Number of connections - FBD Yes
• overall 96 - STL Yes
• usable for PG communication - SCL Yes
- reserved for PG communication 1 - CFC Yes
• usable for OP communication - GRAPH Yes
- reserved for OP communication 1 - HiGraph® Yes
S7 message functions • Software libraries
Number of login stations for 62 - Easy Motion Control Yes
message functions, max. - Software redundancy Yes; As of V1.2, only operation of
SCAN procedure No WinAC RTX with WinAC RTX
• Number of simultaneously active
Process diagnostic messages Yes; ALARM_S, ALARM_SQ, SFCs
ALARM_D, ALARM_DQ - DPSYC_FR 20; of a total of 20 for all SFCs
simultaneously active 20; of a total of 20 for all SFCs - D_ACT_DP 20; of a total of 20 for all SFCs
Alarm-S blocks, max. - RD_REC 20; of a total of 20 for all SFCs
Alarm 8-blocks Yes - WR_REC 20; of a total of 20 for all SFCs
• Number of instances for alarm 8 4 000 - WR_PARM 20; of a total of 20 for all SFCs
and S7 communication blocks, max. - PARM_MOD 20; of a total of 20 for all SFCs
- WR_DPARM 20; of a total of 20 for all SFCs
Process control messages No
- DPNRM_DG 20; of a total of 20 for all SFCs
Number of archives that can log on 32 - RDSYSST 20; of a total of 20 for all SFCs
simultaneously (SFB 37 AR_SEND) • Number of simultaneously active
Test commissioning functions SFBs
Status block Yes - RD_REC 20; of a total of 20 for all SFBs
- WR_REC 20; of a total of 20 for all SFBs
Single step Yes
Know-how protection
Number of breakpoints 20
• User program protection/password Yes
Status/control protection
• Status/control variable Yes • Block encryption No
Forcing Open Development interfaces
• Forcing No • CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher
Diagnostic buffer • CMI (Controller Management Inter- Yes; WinAC ODK V4.2 or higher
face)
• present Yes
• SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher
• Number of entries, max.
- Inputs 4 kbyte
- adjustable Yes
- Outputs 4 kbyte
- preset 120
I/O/Options
Hardware requirements
I/O devices none
Hardware required PC with color monitor, keyboard,
mouse or pointing device for Windows • Printer No
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
2
deterministic requirements; Our add-ons supplement the WinAC RTX soft PLC by useful
PROFIBUS and PROFINET; functions which have arisen in the context of projects. You can
CD-ROM with electronic documen- thus fully utilize the advantages of PC-based automation.
tation d, e, f;
single license, executable under The applications are available in the form of function blocks and
Windows XP SP2 and SP3 as well are easy to use without special programming knowledge.
as Windows 7 (32 bit)
SIMATIC WinAC RTX 2010 6ES7671-0RC08-0YE0 Detailed information and prices can be obtained from your
Upgrade Siemens contact or from:
For upgrading from basic/RTX V3.x, Contact:
V4.0, V4.1 2005, 2008 and 2009;
single license, executable under Siemens AG
Windows XP SP2 and SP3 and Competence Center Cologne
Windows 7 (32 bit) E-mail: CCCologne@siemens.com
CP 5612 6GK1561-2AA00
communications processor Application Function
PCI card (32 bit) for connection WinAC serial driver Communication over serial interfaces
of a programming device or PC
to PROFIBUS WinAC PC IO driver Access to central I/O expansion PC
IO including interrupt handling
CP 5622 6GK1562-2AA00
communications processor WinAC SQL Access to SQL databases
PCI Express x1 card (32 bit) WinAC TCP/IP driver Data exchange between WinAC and
other communication partners over
for connection of a programming
Windows interface using TCP/IP,
device or PC to PROFIBUS
UDP, or ISO-on-TCP
CP 5603 Microbox Package 6GK1560-3AU00
WinAC OPC Client Access to various OPC servers
Comprising CP 5603 module and
Microbox expansion rack WinAC Shutdown Controlled shutdown of WinAC and
PC system
CP 5613 A2 6GK1561-3AA01
communications processor WinAC File-I/O Reading and writing of DBs as file
on the PC system
PCI card (32 bit; 3.3 V/5 V) for
connection to PROFIBUS incl. DP- WinAC Command Calling of batch commands from
WinAC
Base software with NCM PC;
DP-RAM interface for DP master, WinAC Access-DB High-performance access to DBs,
incl. PG and FDL protocol; bit memories or I/O image
single license for 1 installation,
runtime software, software and WinAC SMX Cover Provision of SMX functions, e.g. for
electronic manual on CD-ROM, Delphi or VB
Class A, for 32 bit Windows 2000 WinAC CMI Wrapper Simple program-based operation
Professional/Server, of WinAC
Windows XP Professional,
German/English
Brochures
CP 5623 6GK1562-3AA00
communications processor Information material for downloading can be found
in the Internet:
PCI Express x1 card (32 bit) for
connection to PROFIBUS incl. DP- http://www.siemens.com/simatic/printmaterial
Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL proto-
cols; single license for 1 installation,
runtime software, software and
electronic manual on CD-ROM,
Class A, for operating system
support see SIMATIC NET software;
German/English
CP 1616 6GK1161-6AA02
communications processor
PCI Card (32 bit; 3.3/5 V universal
key) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO controller (RT opera-
tion) and NCM PC;
single license for one installation,
runtime software, software and
electronic manual on CD-ROM,
Class A, for 32 bit Windows XP
Professional;
German/English
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
New:
■ Overview • SIMATIC IPC427D and IPC477D are fully supported
- Communication via onboard CP 5622
- Retentive memory
- LED display of the operating status
■ Benefits
• Hard real-time and maximum performance up to SIL 3
according to IEC 61508/62061 or according to
EN ISO 13849-1 up to PL e
• Implementation of fast, S7-compatible control solutions with
low processor loading.
Alongside the control task, sufficient processor capability is
available for processing complex, demanding PC applica-
tions in parallel.
■ Technical specifications
6ES7671-1RC08-0YA0 6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010 SIMATIC WinAC RTX F 2010
General information FB
Hardware product version - • Number, max. 65 536;
Limited only by RAM set for code
Firmware version V4.6
• Size, max. 64 kbyte
Engineering with
FC
• Programming package STEP 7 V5.5 or higher + hardware • Number, max. 65 536;
update / iMap V3.0 SP1 / Limited only by RAM set for code
option package S7 Distributed Safety • Size, max. 64 kbyte
V5.4 + SP5 / S7 F Configuration Pack
V5.5 + SP6 + HF1 OB
Memory • Size, max. 64 kbyte
Type of memory RAM • Number of free cycle OBs 1
• Number of time alarm OBs 1
Work memory
• Number of delay alarm OBs 1
• integrated (for program) 4 Mbyte; Adjustable; depends on • Number of time interrupt OBs 9
Non Paged Memory Pool
• Number of process alarm OBs 1
• integrated (for data) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool • Number of ODK OBs 3; OB 52-54
• Number of DPV1 alarm OBs 3; OB 55-57
Load memory
• Number isochronous mode OBs 2; OB 61-62
• integrated RAM, max. Adjustable; depends on
• Number of startup OBs 2
Non Paged Memory Pool
• Number of asynchronous error OBs 7
CPU processing times • Number of synchronous error OBs 2
for bit operations, typ. 0.004 µs
Nesting depth
for fixed point arithmetic, typ. 0.003 µs • per priority class 24
for floating point arithmetic, typ. 0.004 µs • additional within an error OB 24
Reference platform Pentium IV, 2.4 GHz
CPU-blocks
DB
• Number, max. 65 535;
Limited only by RAM set for code
• Size, max. 64 kbyte
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
and their retentivity I/O address area
S7 counter • Inputs 16 kbyte
• Number 2 048 • Outputs 16 kbyte
• Retentivity • of which, distributed
- adjustable Yes - DP interface, inputs 16 kbyte
- lower limit 0 - DP interface, outputs 16 kbyte
- upper limit 2 047 - PN interface, inputs 16 kbyte
- preset 8 - PN interface, outputs 16 kbyte
• Counting range
Process image
- adjustable Yes
• Inputs, adjustable 8 kbyte
- lower limit 0
• Outputs, adjustable 8 kbyte
- upper limit 999
• Inputs, default 512 byte
IEC counter • Outputs, default 512 byte
• present Yes
Subprocess images
• Type SFB
• Number of subprocess images, 15
• Number Unlimited max.
(limited only by RAM capacity)
Digital channels
S7 times
• Inputs 128 000
• Number 2 048
• Outputs 128 000
• Retentivity
- adjustable Yes Analog channels
- lower limit 0 • Inputs 8 000
- upper limit 2 047 • Outputs 8 000
- preset 0 Hardware configuration
• Time range Submodules
- lower limit 10 ms • Number of submodules, max 4
- upper limit 9 990 s • of which PROFIBUS, max. 4; Supported interfaces:
IEC timer see 1st and 2nd interface
• present Yes • of which Industrial Ethernet, max. 1; Supported interfaces:
see 3rd and 4th interface
• Type SFB
• Number Unlimited Number of operable FMs and CPs
(limited only by RAM capacity) (recommended)
• FM 4; FM distributed:
Data areas and their retentivity FM 350-1, FM 350-2, FM 351,
Retentivity without UPS 128 kbyte with SIMATIC IPC427C FM 352 / FM 352-5, FM 353, FM 354,
and PS Extension Board and HMI IPC477C; FM 355, FM 355-2
further SIMATIC PCs on request • CP, point-to-point 2; CP 340, CP 341 distributed
Retentivity with UPS all data • CP, LAN Over PC CP
Flag Time of day
• Number, max. 16 kbyte Clock
• of which retentive MB 0 to MB 16383 • Hardware clock (real-time clock) Yes
• Retentivity preset MB 0 to MB 15 • battery-backed and synchronizable Yes
• Number of clock memories 8 Operating hours counter
Data blocks • Number 8
• Number, max. Limited only by available retentive Clock synchronization
memory (NVRAM, or file storage)
• supported Yes
• Size, max. 64 kbyte
• to PC-CP, slave Yes
• Retentivity adjustable Yes; via non-retain property on DB
• on Ethernet via NTP Yes
• Retentivity preset Yes
Local data
• adjustable, max. 64 kbyte
• preset 32 kbyte
• per priority class, max. 61 440 byte
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
With optical interface No Interface type CP 5613, CP 5613-A2, CP 5603,
CP 5623
1st interface
Interface type CP 5611-A2, CP 5621, integrated PB Max. no. of simultaneously 4
interface of the SIMATIC PC operable CPs
Max. no. of simultaneously 1 Physics RS 485 / PROFIBUS
operable CPs Isolated Yes
Physics RS 485 / PROFIBUS Functionality
Isolated Yes • MPI No
Power supply to interface does not exist • DP master Yes
(15 to 30 V DC), max. • DP slave No
Number of connection resources 8 DP master
• Number of connections, max. 50
Functionality
• Transmission rate, max. 12 Mbit/s
• MPI No
• Number of DP slaves, max. 125
• DP master Yes
• Services
• DP slave No
- PG/OP communication Yes
DP master - Routing Yes
• Number of connections, max. 8 - Global data communication No
• Transmission rate, max. 12 Mbit/s - S7 basic communication No
• Number of DP slaves, max. 64 - S7 communication Yes
• Services - S7 communication, as client Yes
- PG/OP communication Yes - S7 communication, as server Yes
- Routing Yes - Equidistance mode support Yes; Only in conjunction with
- Global data communication No isochronous mode
- S7 basic communication No - Isochronous mode Yes
- S7 communication Yes - SYNC/FREEZE Yes
- S7 communication, as client Yes - Activation/deactivation of DP Yes
- S7 communication, as server Yes slaves
- Equidistance mode support Yes; Only in conjunction - Direct data exchange (slave-to- Yes
with isochronous mode slave communication)
- Isochronous mode Yes - DPV0 Yes
- SYNC/FREEZE Yes - DPV1 Yes
- Activation/deactivation of DP Yes • Address area
slaves - Inputs, max. 16 kbyte
- Direct data exchange Yes - Outputs, max. 16 kbyte
(slave-to-slave communication) • User data per DP slave
- DPV0 Yes - Inputs, max. 244 byte
- DPV1 Yes - Outputs, max. 244 byte
• Address area
3rd interface
- Inputs, max. 16 kbyte
Interface type PROFINET
- Outputs, max. 16 kbyte
• User data per DP slave Max. no. of simultaneously 1; Intel Pro/1000 (Intel 82571EB,
- Inputs, max. 244 byte operable CPs 82573L, 82574L, 82541PI;
non-shared IRQ required); integrated
- Outputs, max. 244 byte IE interface SIMATIC PC 4x7B, 6x7B,
8x7B, IPC4x7C, IPC6x7C, IPC8x7C
Physics Ethernet
Isolated Yes
Integrated switch No
Number of ports 1
Automatic detection of transmission Yes; 10/100 Mbit/s
speed
Autonegotiation Yes
Autocrossing Yes
Media redundancy
• supported No
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
• PROFINET IO Controller Yes Interface type PROFINET
• PROFINET IO Device No Max. no. of simultaneously operable 1
• PROFINET CBA Yes CPs
• Open IE communication Yes
Physics Ethernet
PROFINET IO Controller
Isolated Yes
• Transmission rate, min. 100 Mbit/s
• Transmission rate, max. 100 Mbit/s Integrated switch Yes
• Number of connectable IO devices, 128 Number of ports 3
max.
• Max. number of connectable 128 Automatic detection of transmission Yes; 10/100 Mbit/s
IO devices for RT speed
- of which in line, max. 128 Autonegotiation Yes
• IRT, supported No Autocrossing Yes
• Prioritized startup supported Yes
- Number of IO Devices, max. 32 Change of IP address at runtime, Yes
supported
• Activation/deactivation of Yes
IO Devices Number of connection resources 32
- Maximum number of IO devices 8 Media redundancy
that can be activated/deactivated
at the same time. • supported Yes
• IO Devices changing during opera- Yes • Switchover time on line break, 200 ms
tion (partner ports), supported typically
• Device replacement without swap Yes • Number of stations in the ring, max. 50
medium Functionality
• Send cycles 1 ms • PROFINET IO Controller Yes
• Updating time 1 - 512 ms (minimum value depends • PROFINET IO Device No
on communication share set for • PROFINET CBA Yes
PROFINET I/O, on the number
of I/O devices, and on the volume of • Open IE communication Yes
configured user data) • Web server Yes
• Services PROFINET IO Controller
- PG/OP communication Yes • Transmission rate, max. 100 Mbit/s
- Routing Yes; S7 routing • Max. number of connectable 256
- S7 communication Yes IO devices for RT
- Isochronous mode No - of which in line, max. 256
- Open IE communication Yes • Number of IO devices with IRT and 64
• Address area the option "high flexibility"
- Inputs, max. 16 kbyte - of which in line, max. 32
- Outputs, max. 16 kbyte • Number of IO Devices with IRT and 64
- User data per address area, max. 2 kbyte the option "high performance", max.
- User data consistency, max. 254 byte - of which in line, max. 64
• IRT, supported Yes
PROFINET CBA • Prioritized startup supported Yes
• acyclic transmission Yes - Number of IO Devices, max. 32
• Cyclic transmission Yes • Activation/deactivation of Yes
SIMATIC communication IO Devices
• PG/OP communication Yes - Maximum number of IO devices 8
• S7 routing Yes that can be activated/deactivated
at the same time.
• S7 communication Yes
• IO Devices changing during opera- Yes
• Number of connections, max. 16 tion (partner ports), supported
Open IE communication • Device replacement without swap Yes
• Open IE communication, supported Yes medium
• Number of connections, max. 32 • Send cycles 250 µs, 500 µs, 1 ms
• Local port numbers used at the 0, 20, 21, 23, 25, 80, 102, 135, 161, • Updating time 0.25...512
system end 8080, 34962, 34963, 34964, 65532, depending on the send cycle
65533, 65534, 65535 • Services
• Keep-alive function, supported Yes - PG/OP communication Yes
- Routing Yes; S7 routing
- S7 communication Yes
- Isochronous mode Yes
- Open IE communication Yes
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
- Inputs, max. 16 kbyte (at set setpoint communication load)
- Outputs, max. 16 kbyte • Setpoint for the CPU 20 %
- User data per address area, max. 2 kbyte communication load
- User data consistency, max. 254 byte • Number of remote interconnection 64
partners
SIMATIC communication • Number of functions, master/slave 30
• PG/OP communication Yes • Total of all Master/Slave 1 000
• S7 routing Yes connections
• S7 communication Yes • Data length of all incoming 6 800 byte
• Number of connections, max. 32 connections master/slave, max.
• Data length of all outgoing 6 800 byte
Open IE communication connections master/slave, max.
• Open IE communication, supported Yes • Number of device-internal and 500
• Number of connections, max. 32 PROFIBUS interconnections
• Local port numbers used at the 0, 20, 21, 25, 80, 102, 135, 161, • Data length of device-internal and 4 000 byte
system end 34962, 34963, 34964, 65532, 65533, PROFIBUS interconnections, max.
65534, 65535 • Data length per connection, max. 1 400 byte
Isochronous mode • Remote interconnections
Isochronous operation (application Yes with acyclic transmission
synchronized up to terminal) - Sampling frequency: 500 ms
Sampling time, min.
Number of DP masters with 2
- Number of incoming 100
isochronous mode
interconnections
User data per isochronous slave, 128 byte - Number of outgoing 100
max. interconnections
Equidistance Yes - Data length of all incoming 2 000 byte
- interconnections, max.
Shortest clock pulse 2.2 ms; - Data length of all outgoing 2 000 byte
2.2 ms without partial process image; - interconnections, max.
2.2 ms with partial process image
- Data length per connection, max. 1 400 byte
Communication functions • Remote interconnections with cyclic
PG/OP communication Yes transmission
Data record routing Yes; Only with CP 5611 or integrated - Transmission frequency: 10 ms
PROFIBUS interface of the Transmission interval, min.
SIMATIC PC - Number of incoming 200
interconnections
Global data communication
- Number of outgoing 200
• supported No interconnections
S7 basic communication - Data length of all incoming 4 800 byte
• supported No interconnections, max.
- Data length of all outgoing 4 800 byte
S7 communication interconnections, max.
• supported Yes - Data length per connection, max. 250 byte
• as server Yes • HMI variables via PROFINET
• As client Yes (acyclic)
• User data per job, max. 64 kbyte; - Number of stations that can log on 3
Depends on which block is used: for HMI variables (PN OPC/iMap)
BSEND/USEND or PUT/GET - HMI variable updating 500 ms
Open IE communication - Number of HMI variables 200
• TCP/IP Yes - Data length of all HMI variables, 2 000 byte
- Number of connections, max. 32 max.
- Data length for connection type Not supported • PROFIBUS proxy functionality
01H, max. - supported Yes
- Data length for connection type 65 534 byte - Number of linked PROFIBUS 16
11H, max. devices
- Data length, max. 65 534 byte - Data length per connection, max. 240 byte; Slave-dependent
• ISO-on-TCP (RFC1006) Yes Number of connections
- Number of connections, max. 32 • overall 96
- Data length, max. 65 534 byte • usable for PG communication
• UDP Yes - reserved for PG communication 1
- Number of connections, max. 32 • usable for OP communication
- Data length, max. 1 472 byte - reserved for OP communication 1
Web server
• Supported Yes
• Number of HTTP clients 2
• User-defined websites No
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
Number of login stations for message 62 Configuration software
functions, max. • STEP 7 Yes; As of V5.5 + HW update/S7 F
SCAN procedure No Configuration Pack V5.5 + SP6 +
HF1/option package S7 Distributed
Process diagnostic messages Yes; ALARM_S, ALARM_SQ, Safety V5.4 + SP5 or later
ALARM_D, ALARM_DQ
programming
simultaneously active 20; • Nesting levels 8
Alarm-S blocks, max. of a total of 20 for all SFCs
• Programming language
Alarm 8-blocks Yes - LAD Yes
• Number of instances for alarm 8 4 000 - FBD Yes
and S7 communication blocks, max.
- STL Yes
Process control messages No - SCL Yes
Test commissioning functions - CFC Yes
Status block Yes - GRAPH Yes
- HiGraph® Yes
Single step Yes
• Software libraries
Number of breakpoints 20 - Easy Motion Control Yes
Status/control - Software redundancy Yes; As of V1.2, only for operation of
WinAC RTX (F) with WinAC RTX (F)
• Status/control variable Yes
• Number of simultaneously active
Forcing SFCs
• Forcing No - DPSYC_FR 20; of a total of 20 for all SFCs
Diagnostic buffer - D_ACT_DP 20; of a total of 20 for all SFCs
• present Yes - RD_REC 20; of a total of 20 for all SFCs
• Number of entries, max. - WR_REC 20; of a total of 20 for all SFCs
- adjustable Yes - WR_PARM 20; of a total of 20 for all SFCs
- preset 120 - PARM_MOD 20; of a total of 20 for all SFCs
- WR_DPARM 20; of a total of 20 for all SFCs
Hardware requirements
- DPNRM_DG 20; of a total of 20 for all SFCs
Hardware required PC with color monitor, keyboard,
- RDSYSST 20; of a total of 20 for all SFCs
mouse or pointing device
for Windows • Number of simultaneously active
SFBs
Main memory, min. 1 Gbyte - RD_REC 20; of a total of 20 for all SFBs
Required memory on hard disk, min. 100 Mbyte - WR_REC 20; of a total of 20 for all SFBs
Processor Intel Celeron M 900 MHz or compati- Know-how protection
ble (older PC systems with Program- • User program protection/password Yes
mable Interrupt Controllers (PIC) are protection
not suitable for WinAC RTX F 2010.) • Block encryption No
• Multi-processor system No
• Hyper-threading Yes Open Development interfaces
• CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher
Operating systems • CMI (Controller Management Inter- Yes; WinAC ODK V4.2 or higher
Windows NT 4.0 No face)
Windows 2000 No • SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher
- Inputs 4 kbyte
Windows XP Yes; Professional, SP2 and SP3
- Outputs 4 kbyte
Windows XP embedded Yes; With the delivery image of the
SIMATIC PC I/O/Options
• Supported HAL types under Win- ACPI uniprocessor PC, I/O devices none
dows XP ACPI multiprocessor PC, • Printer No
MPS multiprocessor PC Weights
Windows Vista No Weight, approx. 100 g;
Weight incl. packaging
Windows 7 Yes; Professional, Enterprise,
Ultimate (only 32 bits)
Windows embedded Standard 7 No
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
2
Our add-ons supplement the WinAC RTX soft PLC by useful
CP 5612 6GK1561-2AA00
communications processor functions which have arisen in the context of projects. In this
way, you can fully utilize the advantages of PC based Automa-
PCI card (32 bit) for connection tion.
of a programming device or PC
to PROFIBUS The applications are available in the form of function blocks and
CP 5621 6GK1562-2AA00 are easy to use without special programming knowledge.
communications processor
Detailed information and prices can be obtained from your
PCI Express x1 card (32 bit) Siemens contact or from:
for connection of a programming
device or PC to PROFIBUS Contact:
CP 5603 Microbox Package 6GK1560-3AU00 Siemens AG
Comprising CP 5603 module and Competence Center Cologne
Microbox expansion rack E-mail: CCCologne@siemens.com
CP 5613 A2 6GK1561-3AA01
communications processor Application Function
PCI card (32 bit; 3.3 V/5 V) for con- WinAC serial driver Communication over serial interfaces
nection to PROFIBUS incl. DP-Base WinAC PC IO driver Access to central I/O expansion PC
software with NCM PC; IO including interrupt handling
DP-RAM interface for DP master,
incl. PG and FDL protocol; WinAC SQL Access to SQL databases
single license for 1 installation,
WinAC TCP/IP driver Data exchange between WinAC and
runtime software, software and
other communication partners over
electronic manual on CD-ROM,
Windows interface using TCP/IP,
Class A, for 32 bit Windows 2000
UDP, or ISO-on-TCP
Professional/Server,
Windows XP Professional, WinAC OPC Client Access to various OPC servers
German/English
WinAC Shutdown Controlled shutdown of WinAC and
CP 5623 6GK1562-3AA00 the PC system
communications processor
WinAC File I/O Reading and writing of DBs as a file
PCI Express x1 card (32 bit) for on the PC system
connection to PROFIBUS incl. DP-
Base software with NCM PC; WinAC Command Calling batch commands from WinAC
DP-RAM interface for DP master or WinAC Access DB High-performance accesses to DBs,
DP slave, incl. PG and FDL proto- bit memories or I/O image
cols; single license for 1 installation,
runtime software, software and WinAC SMX Cover Provides SMX functions, e.g. for
electronic manual on CD-ROM, Delphi or VB
Class A, for operating system sup-
port see SIMATIC NET software; WinAC CMI Wrapper Easy program-controlled operation
German/English of WinAC
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC ODK
■ More information
Brochures
Information material for downloading can be found
in the Internet:
http://www.siemens.com/simatic/printmaterial
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
■ Overview ■ Function
• Control:
For the optimum control of processes with WinAC RTX, several
processing levels are available:
- Cyclic program processing
2 - Interrupt processing
- Time and date-controlled processing
• Functional safety with WinAC RTX F for EC31-RTX F:
The functional safety is implemented by means of targeted
safety functions in the software. Safety functions are imple-
mented with S7 Distributed Safety, to place the plant in a safe
state or to hold it in a safe state. The safety functions are
mainly included in the following components:
- In the safety-related user program (safety program)
in WinLC RTX F
- In the fail-safe inputs and outputs (F I/O).
The F I/O ensures reliable processing of the field information
(emergency stop pushbutton, light barriers, motor control). It
features all the hardware and software components required
for reliable processing, according to the required safety
class. The user only programs the user safety functions. The
• Get off to a fast start in automation solutions with embedded safety functions for the process can be implemented with a
PC platforms. user safety function or a system-internal fault reaction
- Ready-to-use SIMATIC WinAC RTX or WinAC RTX F function. If the F system is unable to execute the actual user
preinstalled on EC31 safety function, it will execute the fault response function:
- Prepared for use in a SIMATIC environment with PROFINET e.g. deactivation of the associated outputs and, if appro-
and Industrial Ethernet priate, F-CPU in STOP.
- Commissioning by specialist automation personnel as with • Retentivity:
the S7-300 The controller can back up 512 KB of retentive data on an
- Configuring and programming with SIMATIC STEP 7 over integrated, non-volatile memory, without the need for a UPS.
Industrial Ethernet Total retentivity of all process values of SIMATIC WinAC RTX
- Optional visualization can be achieved with a generally available UPS.
• Modular expansion capability: • Access to process values:
Central expansion with The SIMATIC NET OPC server supplied with EC31-RTX
- S7-300 I/O (SM modules of S7-300) permits open access to all process values. Visualization
- Expansion modules for additional PC interfaces, e.g. DVI-I, systems or data processing systems can be linked to
USB, Gigabit Ethernet networks and memory card slots, SIMATIC WinAC RTX via this interface.
as well as PCI-104
• Communication:
• Rugged operation The Windows Automation Center (WinAC) is programmed with
- Hard-disk-free operation based on flash disk and Windows SIMATIC STEP 7 via the integral Industrial Ethernet interface.
Embedded Standard The SIMATIC NET SOFTNET Lean communication package is
- Fan-free operation pre-installed for this purpose.
• Flexibility of a PC-based automation environment • Use of other software:
- Free memory space on flash disk can be used for other PC The customer can install supporting software products.
applications Windows Embedded Standard is designed so that typical
- Use of WinAC ODK with SIMATIC WinAC RTX and WinAC add-on packages can be installed.
RTX F (read-only in safety-related program part)
- Connection option for USB devices
- Memory capacity expandable using multimedia card
• Data retentivity for WinAC RTX and RTX F without uninter-
ruptible power supply (UPS)
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
■ Technical specifications
6ES7677-1DD10- 6ES7677-1DD10- 6ES7677-1FD10- 6ES7677-1DD10- 6ES7677-1DD10- 6ES7677-1DD10-
0BA0 0BB0 0FB0 0BF0 0BG0 0BH0
SIMATIC S7-mEC, S7-mEC, S7-mEC, S7-mEC, S7-mEC, S7-mEC,
EC31 EC31-RTX EC31-RTX F EC31-HMI/RTX EC31-HMI/RTX EC31-HMI/RTX
General information
128PT 512PT 2048PT
2
Hardware product version 01 01 01 01 01 01
Firmware version V2.0 V2.0 V2.0 V2.0 V2.0 V2.0
PC configuration
Computer platform SIMATIC S7 SIMATIC S7 SIMATIC S7 SIMATIC S7 SIMATIC S7 SIMATIC S7
modular embed- modular embed- modular embed- modular embed- modular embed- modular embed-
ded controller ded controller ded controller ded controller ded controller ded controller
Processor selection Intel Core Duo Intel Core Duo 1.2 Intel Core Duo 1.2 Intel Core Duo 1.2 Intel Core Duo 1.2 Intel Core Duo 1.2
1.2 GHz GHz GHz GHz GHz GHz
Main memory 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM
Flash Disk 4 Gbyte 4 Gbyte 4 Gbyte 4 Gbyte 4 Gbyte 4 Gbyte
Operating systems Windows Embed- Windows Embed- Windows Embed- Windows Embed- Windows Embed- Windows Embed-
ded Standard 2009 ded Standard 2009 ded Standard 2009 ded Standard 2009 ded Standard 2009 ded Standard 2009
Installed software
• Visualization WinCC flexible RT WinCC flexible RT WinCC flexible RT
2008 SP2, incl. 2008 SP2, incl. 2008 SP2, incl.
Sm@rtAccess, Sm@rtAccess, Sm@rtAccess,
recipes, archives recipes, archives recipes, archives
options options options
• Control SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC
RTX 2010 RTX F 2010 RTX 2010 RTX 2010 RTX 2010
• Communication Yes Yes Yes Yes Yes
Supply voltage
Rated value, 24 V DC Yes Yes Yes Yes Yes Yes
Permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V
Permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V
Mains buffering
• Mains/voltage failure stored 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms
energy time
Input current
Rated value at 24 V DC 800 mA; without 800 mA; without 800 mA; without 800 mA; without 800 mA; without 800 mA; without
backplane bus and backplane bus and backplane bus and backplane bus and backplane bus and backplane bus and
USB power supply USB power supply USB power supply USB power supply USB power supply USB power supply
Power losses
Power loss, typ. 34 W 34 W 34 W 34 W 34 W 34 W
Memory
Type of memory 256 KB non-volatile 512 KB non-volatile 512 KB non-volatile 512 KB non-volatile 512 KB non-volatile 512 KB non-volatile
memory for reten- memory for reten- memory for reten- memory for reten- memory for reten- memory for reten-
tive data tive data tive data tive data tive data tive data
Work memory
• integrated 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte
CPU processing times
for bit operations, typ. 0.004 µs 0.004 µs 0.004 µs 0.004 µs 0.004 µs
for fixed point arithmetic, typ. 0.003 µs 0.003 µs 0.003 µs 0.003 µs 0.003 µs
for floating point arithmetic, typ. 0.004 µs 0.004 µs 0.004 µs 0.004 µs 0.004 µs
CPU-blocks
DB
• Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
FB
• Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
FC
• Number, max. Max. code size Max. code size Max. code size Max. code size Max. code size
and max. data and max. data and max. data and max. data and max. data
size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each
• Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
OB
• Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
• Number of free cycle OBs 1 1 1 1 1
• Number of time alarm OBs 1 1 1 1 1
• Number of delay alarm OBs 1 1 1 1 1
• Number of time interrupt OBs 9 9 9 9 9
• Number of process alarm OBs 1 1 1 1 1
• Number of startup OBs 2 2 2 2 2
• Number of asynchronous error OBs 7 7 7 7 7
• Number of synchronous error OBs 2 2 2 2 2
Nesting depth
• per priority class 24 24 24 24 24
• additional within an error OB 24 24 24 24 24
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
2
128PT 512PT 2048PT
Counters, timers
and their retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048 2 048
• Retentivity
- adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
- upper limit 2 047 2 047 2 047 2 047 2 047
- preset 8 8 8 8 8
• Counting range
- adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
- upper limit 999 999 999 999 999
IEC counter
• present Yes Yes Yes Yes Yes
• Type SFB SFB SFB SFB SFB
S7 times
• Number 2 048 2 048 2 048 2 048 2 048
• Retentivity
- adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
- upper limit 2 047 2 047 2 047 2 047 2 047
• Time range
- lower limit 10 ms 10 ms 10 ms 10 ms 10 ms
- upper limit 9 990 s 9 990 s 9 990 s 9 990 s 9 990 s
IEC timer
• present Yes Yes Yes Yes Yes
• Type SFB SFB SFB SFB SFB
Data areas and their retentivity
retentive data area, total 512 KB 512 KB 512 KB 512 KB 512 KB
Flag
• Number, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
• of which retentive without battery MB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383
• Retentivity preset MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15
• Number of clock memories 8 8 8 8 8
Data blocks
• Number, max. Max. code size Max. code size Max. code size Max. code size Max. code size
and max. data and max. data and max. data and max. data and max. data
size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each
• Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
Address area
I/O address area
• Inputs 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
• Outputs 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
• of which, distributed
- Inputs 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte
- Outputs 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte
Process image
• Inputs, adjustable 16 kbyte 16 kbyte 8 kbyte 8 kbyte 8 kbyte
• Outputs, adjustable 16 kbyte 16 kbyte 8 kbyte 8 kbyte 8 kbyte
• Inputs, default 512 byte 512 byte 512 byte 512 byte 512 byte
• Outputs, default 512 byte 512 byte 512 byte 512 byte 512 byte
Subprocess images
• Number of subprocess images, max. 15 15 15 15 15
Digital channels
• Inputs 128 000 128 000 128 000 128 000 128 000
• Outputs 128 000 128 000 128 000 128 000 128 000
Analog channels
• Inputs 8 000 8 000 8 000 8 000 8 000
• Outputs 8 000 8 000 8 000 8 000 8 000
Hardware configuration
Integrated power supply Yes Yes Yes Yes Yes
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes; Resolution: 1 s Yes Yes Yes
Clock synchronization
• supported Yes Yes Yes Yes Yes
• to PC-CP, slave Yes Yes Yes Yes Yes
• on Ethernet via NTP Yes Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
2
128PT 512PT 2048PT
Interfaces
Number of USB interfaces 2 2 2 2 2
Serial interface 0 0 0 0 0
Industrial Ethernet
• Industrial Ethernet interface X1: 2 ports 10/100 X1: 2 ports 10/100 X1: 2 ports 10/100 X1: 2 ports 10/100 X1: 2 ports 10/100 X1: 2 ports 10/100
Mbit/s (ERTEC- Mbit/s (ERTEC- Mbit/s (ERTEC- Mbit/s (ERTEC- Mbit/s (ERTEC- Mbit/s (ERTEC-
based) X2: 1 port based) X2: 1 port based) X2: 1 port based) X2: 1 port based) X2: 1 port based) X2: 1 port
10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s
1st interface
Interface type PROFINET PROFINET PROFINET PROFINET PROFINET
Physics 2x RJ45 2x RJ45 2x RJ45 2x RJ45 2x RJ45
Automatic detection of transmission Yes Yes Yes Yes Yes
speed
Autonegotiation Yes Yes Yes Yes Yes
Autocrossing Yes Yes Yes Yes Yes
Number of connection resources 32 32 32 32 32
Functionality
• MPI No
• DP master No
• DP slave No
• PROFINET IO Device No No No No No
• PROFINET IO Controller Yes Yes Yes Yes Yes
• PROFINET CBA Yes Yes Yes Yes Yes
• Open IE communication Yes Yes Yes Yes Yes
• Point-to-point connection No
PROFINET IO Controller
• Number of connectable IO devices, 256 256 256 256 256
max.
• Max. number of connectable IO de- 256 256 256 256 256
vices for RT
- of which in line, max. 256 256 256 256 256
• Number of IO devices with IRT and 256 256 256 256 256
the option "high flexibility"
- of which in line, max. 61 61 61 61 61
• Number of IO Devices with IRT and 256 256 256 256 256
the option "high performance", max.
- of which in line, max. 64 64 64 64 64
• IRT, supported Yes Yes Yes Yes Yes
• Prioritized startup supported Yes Yes Yes Yes Yes
- Number of IO Devices, max. 32 32 32 32 32
• Activation/deactivation of IO Devices Yes Yes Yes Yes Yes
- Maximum number of IO devices 8 8 8 8 8
that can be activated/deactivated
at the same time.
• IO Devices changing during opera- Yes Yes Yes Yes Yes
tion (partner ports), supported
- Max. number of IO devices per tool 8 8 8 8 8
• Device replacement without swap Yes Yes Yes Yes Yes
medium
• Send cycles Adjustable: 250 µs, Adjustable: 250 µs, Adjustable: 250 µs, Adjustable: 250 µs, Adjustable: 250 µs,
500 µs and 1 ms 500 µs and 1 ms 500 µs and 1 ms 500 µs and 1 ms 500 µs and 1 ms
• Updating times 250 µs - 128 ms 250 µs - 128 ms 250 µs - 128 ms 250 µs - 128 ms 250 µs - 128 ms
(with signal cycle (with signal cycle (with signal cycle (with signal cycle (with signal cycle
250 µs); 500 µs - 250 µs); 500 µs - 250 µs); 500 µs - 250 µs); 500 µs - 250 µs); 500 µs -
256 ms (with signal 256 ms (with signal 256 ms (with signal 256 ms (with signal 256 ms (with signal
cycle 500 µs); cycle 500 µs); cycle 500 µs); cycle 500 µs); cycle 500 µs);
1 ms - 512 ms (with 1 ms - 512 ms (with 1 ms - 512 ms (with 1 ms - 512 ms (with 1 ms - 512 ms (with
signal cycle 1 ms) signal cycle 1 ms) signal cycle 1 ms) signal cycle 1 ms) signal cycle 1 ms)
• Services
- PG/OP communication Yes Yes Yes Yes Yes
- S7 routing Yes Yes Yes Yes Yes
- S7 communication Yes Yes Yes Yes Yes
- Isochronous mode Yes Yes Yes Yes Yes
• Address area
- Inputs, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
- Outputs, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
- User data per address area, max. 2 kbyte 2 kbyte 2 kbyte 2 kbyte 2 kbyte
- User data consistency, max. 256 byte 256 byte 256 byte 256 byte 256 byte
PROFINET CBA
• acyclic transmission Yes Yes Yes Yes Yes
• Cyclic transmission Yes Yes Yes Yes Yes
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
2
128PT 512PT 2048PT
Open IE communication
• Open IE communication, supported Yes Yes Yes Yes Yes
• Number of connections, max. 32 32 32 32 32
• Local port numbers used 0, 20, 21, 23, 25, 0, 20, 21, 23, 25, 0, 20, 21, 23, 25, 0, 20, 21, 23, 25, 0, 20, 21, 23, 25,
at the system end 80, 102, 135, 161, 80, 102, 135, 161, 80, 102, 135, 161, 80, 102, 135, 161, 80, 102, 135, 161,
8 080, 34 962, 8 080, 34 962, 8 080, 34 962, 8 080, 34 962, 8 080, 34 962,
34 963, 34 964, 34 963, 34 964, 34 963, 34 964, 34 963, 34 964, 34 963, 34 964,
65 532, 65 533, 65 532, 65 533, 65 532, 65 533, 65 532, 65 533, 65 532, 65 533,
65 534, 65 535 65 534, 65 535 65 534, 65 535 65 534, 65 535 65 534, 65 535
PROFINET functions
• Detection of accessible nodes, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Assignment of the IP address, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Assignment of the device name, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Topology recognition, supported Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP
MIB, SNMP MIB, SNMP MIB, SNMP MIB, SNMP MIB, SNMP
• Extended network diagnostics with Yes; Standard Yes; Standard Yes; Standard Yes; Standard Yes; Standard
Standard MIB II, supported MIB II, SNMP MIB II, SNMP MIB II, SNMP MIB II, SNMP MIB II, SNMP
2nd interface
Interface type Integrated Ethernet Integrated Ethernet Integrated Ethernet Integrated Ethernet Integrated Ethernet
interface interface interface interface interface
Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45
Automatic detection of transmission Yes Yes Yes Yes Yes
speed
Autonegotiation Yes Yes Yes Yes Yes
Autocrossing No No No No No
Number of connection resources 32 32 32 32 32
Functionality
• PROFINET IO Controller No No No No No
• PROFINET IO Device No No No No No
• PROFINET CBA No No No No No
PROFINET functions
• Detection of accessible nodes, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Assignment of the IP address, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Assignment of the device name, Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
supported
• Topology recognition, supported Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP Yes; LLDP, LLDP
MIB, SNMP MIB, SNMP MIB, SNMP MIB, SNMP MIB, SNMP
• Extended network diagnostics with Yes; Standard Yes; Standard Yes; Standard Yes; Standard Yes; Standard
Standard MIB II, supported MIB II, SNMP MIB II, SNMP MIB II, SNMP MIB II, SNMP MIB II, SNMP
Communication functions
PG/OP communication Yes Yes Yes Yes Yes
Global data communication
• supported No No No No No
S7 basic communication
• supported No No No No No
S7 communication
• supported Yes Yes Yes Yes Yes
• as server Yes Yes Yes Yes Yes
• As client Yes Yes Yes Yes Yes
Open IE communication
• TCP/IP Yes; Via integrated Yes; Via integrated Yes; Via integrated Yes; Via integrated Yes; Via integrated
PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter-
face (X1) and load- face (X1) and load- face (X1) and load- face (X1) and load- face (X1) and load-
able FBs able FBs able FBs able FBs able FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 32 kbyte 32 kbyte 32 kbyte 32 kbyte 32 kbyte
• ISO-on-TCP (RFC1006) Yes; Via integrated Yes; via integrated Yes; Via integrated Yes; Via integrated Yes; Via integrated
PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter-
face (X1) and load- face and loadable face (X1) and load- face (X1) and load- face (X1) and load-
able FBs FBs able FBs able FBs able FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 32 kbyte 32 kbyte 32 kbyte 32 kbyte 32 kbyte
• UDP Yes; Via integrated Yes; Via integrated Yes; Via integrated Yes; Via integrated Yes; Via integrated
PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter- PROFINET inter-
face (X1) and load- face (X1) and load- face (X1) and load- face (X1) and load- face (X1) and load-
able FBs able FBs able FBs able FBs able FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 1 472 byte 1 472 byte 1 472 byte 1 472 byte 1 472 byte
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
2
128PT 512PT 2048PT
Number of connections
• overall 64 64 64 64 64
• usable for PG communication
- reserved for PG communication 1 1 1 1 1
• usable for OP communication
- reserved for OP communication 1 1 1 1 1
S7 message functions
Number of login stations for 62; The alarm func- 62; The alarm func- 62; The alarm func- 62; The alarm func- 62; The alarm func-
message functions, max. tions cannot cur- tions cannot cur- tions cannot cur- tions cannot cur- tions cannot cur-
rently be used for rently be used for rently be used for rently be used for rently be used for
central bus mod- central bus mod- central bus mod- central bus mod- central bus mod-
ules ules ules ules ules
Process diagnostic messages Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S
Test commissioning functions
Status/control
• Status/control variable Yes Yes Yes Yes Yes
Forcing
• Forcing No No No No No
Diagnostic buffer
• present Yes Yes Yes Yes Yes
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class A, Yes Yes Yes Yes Yes Yes
for use in industrial areas
Degree and class of protection
IP20 Yes Yes Yes Yes Yes Yes
Standards, approvals, certificates
CE mark Yes Yes Yes Yes Yes Yes
CSA approval Yes; Included in Yes; Included in Yes; Included in Yes; Included in Yes; Included in Yes; Included in
cULus cULus cULus cULus cULus cULus
cULus Yes Yes Yes Yes Yes Yes
RCM (former C-TICK) Yes Yes Yes Yes Yes Yes
FM approval Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
• Min. 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C
• Max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Storage/transport temperature
• Min. -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
• Max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Vibrations
• Operation, checked according to Yes Yes Yes Yes Yes Yes
IEC 60068-2-6
• Transport tested checked to Yes Yes Yes Yes Yes Yes
IEC 60068-2-6
Shock test
• checked according to Yes Yes Yes Yes Yes Yes
IEC 60068-2-27
• checked according to Yes Yes Yes Yes Yes Yes
IEC 60068-2-29
Shock testing
• checked according to Yes Yes Yes Yes Yes Yes
IEC 60068-2-29
• Operation, checked according to Operation, tested Operation, tested Operation, tested Operation, tested Operation, tested Operation, tested
IEC 60068-2-29 according to according to according to according to according to according to
IEC 60068-2-27 IEC 60068-2-27 IEC 60068-2-27 IEC 60068-2-27 IEC 60068-2-27 IEC 60068-2-27
• Storage/transport, checked to Yes Yes Yes Yes Yes Yes
IEC 60068-2-29
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
EC31
2
128PT 512PT 2048PT
Configuration
Configuration software
• STEP 7 Yes Yes; STEP7 V5.5 Yes Yes Yes
and higher / S7
Distributed Safety
option package
V5.4 + SP5 and
higher
programming
• Programming language
- LAD Yes Yes Yes Yes Yes
- FBD Yes Yes Yes Yes Yes
- STL Yes Yes Yes Yes Yes
- SCL Yes Yes Yes Yes Yes
- CFC Yes Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes Yes
- HiGraph® Yes Yes Yes Yes Yes
Dimensions
Width 160 mm 160 mm 160 mm 160 mm 160 mm 160 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 115 mm 115 mm 115 mm 115 mm 115 mm 115 mm
Weights
Weight, approx. 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg
PROFINET/Industrial Ethernet
Controllers / SIMATIC S7-modular Embedded controllers
Expansion modules
■ Overview
• Expansion modules for SIMATIC S7-modular Embedded
Controller EC31
- EM PCI-104 for additionally accommodating up to 3
PCI-104 cards
- EM PC with additional PC interfaces and slots for memory
media
2
■ Technical specifications
6ES7677-1DD60-1AA0 6ES7677-1DD50-2AA0
EM PCI-104 EM PC
General information
Hardware product version 01 01
Input current
from expansion bus 100 mA 580 mA
Power losses
Power loss, typ. 2.4 W; Without inserted PCI-104 cards 9W
Power loss, max. 14 W
Hardware configuration
Integrated power supply Yes No
Interfaces
Number of USB interfaces 0 2
serial interface 0 1x V.24 (RS232)
Industrial Ethernet
• Industrial Ethernet interface Onboard, 10/100/1 000 Mbit/s, RJ45
Ambient conditions
Operating temperature
• Min. 0 °C 0 °C
• max. 50 °C 50 °C
Dimensions
Width 120 mm; Without bus connector extension bus 80 mm; Without bus connector extension bus
Height 125 mm; Without external voltage connecting terminal 125 mm
Depth 115 mm 115 mm
Weights
Weight, approx. 0.5 kg 0.4 kg
PROFINET/Industrial Ethernet
Controllers / Embedded bundles
SIMATIC IPC227D Bundles
2
without drive, with CF slot,
COM1: RS232,
without operating system,
device version:
Base, DIN rail,
1 x DVI-D graphics interface
2 x 10/100/1 000 Mbps
Ethernet RJ45
4 x USB V2.0 (high current)
CompactFlash slot
24 V DC industrial power supply
Processors / memory configuration /
NVRAM
• Atom E620 (600 MHz), A
512 MB RAM
• Atom E620 (600 MHz), B
512 MB RAM, NVRAM
• Atom E640 (1.0 GHz), 1 GB RAM E
• A quick start in automation solutions with embedded PC • Atom E640 (1.0 GHz), 1 GB RAM, F
platforms NVRAM
- SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled • Atom E660 (1.3 GHz), 2 GB RAM G
on SIMATIC IPC227D and ready for use • Atom E660 (1.3 GHz), 2 GB RAM, H
- PROFINET RT and Industrial Ethernet pre-configured for use NVRAM
in a SIMATIC environment Drives
- Optional WinCC RT Advanced for visualization tasks in
• Without drive, with CF slot 0
parallel with SIMATIC WinAC RTX
- Configuration and programming with SIMATIC STEP 7 via • 320 GB HDD SATA 1
Industrial Ethernet or PROFINET • 160 GB Solid-State Drive SATA 2
• Safety requirements up to SIL 3 in accordance with • 80 GB Solid-State Drive SATA 4
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
• 2 GB SIMATIC IPC CompactFlash 5
implemented with WinAC RTX F.
• Rugged operation • 4 GB SIMATIC IPC CompactFlash 6
- Hard-disk-free operation with CompactFlash card (CF card) • 8 GB SIMATIC IPC CompactFlash 7
or solid-state drive and Windows Embedded Standard 2009 • 16 GB SIMATIC IPC Compact- 8
or Windows Embedded Standard 7, 32-bit Flash
- Fan-free operation
COM interface
- 128 KB of retentive data for WinAC RTX, also without
uninterruptible power supply (UPS) • COM1: RS232 0
• Flexibility of a PC-based automation environment • COM1: RS485 1
- Use of WinAC ODK with SIMATIC WinAC RTX or • COM1: CAN 2
SIMATIC WinAC RTX F (read-only for fail-safe program
Operating system
section)
- Connection option for USB devices, flat panel monitor or • Without operating system 0
screen • Windows Embedded Standard 1
- PCIe cards can be plugged in 2009 preinstalled
(CF from 2 GB/SSD/HD)
See "PC-based Automation -> Industry PC -> Box PC -> • Windows Embedded Standard 7 3
(32-bit) preinstalled
SIMATIC IPC227D" (CF from 4 GB/SSD/HD)
• Windows 7 (32-bit) 4
MUI preinstalled on SSD/HD
■ More information
Delivery
Production and delivery of the devices will typically be
completed within 15 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
PROFINET/Industrial Ethernet
Controllers / Embedded bundles
SIMATIC IPC427D bundles
High system availability in order to reduce the risk of potential
■ Overview failures and maintenance costs
• Maintenance-free since no rotating parts (fans, hard disks)
and operation without battery possible
• 512 KB NVRAM can be written by WinAC RTX
• Front LED for efficient self-diagnostics; optimized for headless
operation through special BIOS properties 2
• SIMATIC software system-tested
High investment security in order to reduce engineering costs
• Long-term availability: Service and support period of
8 to 10 years after market launch
• Installation and interface compatibility with predecessor
versions as of 2004
■ Technical specifications
See "PC-based Automation -> Industry PC -> Box PC ->
SIMATIC IPC427D"
SIMATIC IPC427D (Microbox PC): The powerful embedded
IPC – maintenance-free with versatile configuration ■ Ordering data Article No.
Ready-to-run, complete solutions (software is already installed SIMATIC IPC427D (Box PC) 6AG4140- 7 7 7 7 7 - 7 7 7 7
and preconfigured) for visualization and automation in connec-
tion with WinCC RT Advanced and/or WinAC RTX. Processor and field bus
PROFINET/Industrial Ethernet
Controllers / Embedded bundles
SIMATIC IPC277D bundles
High degree of industrial functionality and flexibility
■ Overview for implementing the embedded solution
• Flexible memory concepts: CompactFlash or Solid-State Drive
• 2 Gbit Ethernet (teaming-capable); PROFINET with RT
functionality (via Standard Ethernet)
PROFINET/Industrial Ethernet
Controllers / Embedded bundles
SIMATIC IPC477D bundles
■ Overview ■ Benefits
• Excellent industrial compatibility due to rugged construction,
even when subjected to extreme vibration and shock
• High degree of investment protection thanks to assured
availability of spare parts for a period of 5 years following the
end of active marketing 2
• Excellent continuity of components for machine concepts with
a long service life without any new engineering costs
• Cost and time savings due to service-friendly device design:
- USB interfaces on the front and rear for quick and easy
connection of additional hardware components
• High degree of industrial functionality thanks to integral
PROFIBUS DP/MPI and PROFINET interfaces
• Maintenance-free due to lack of rotating components
(fan and hard disk)
• High flexibility thanks to expansions (optional) such as PCIe,
second RS232, DVD
• Minimization of downtimes thanks to high system availability
- Efficient self-diagnostics (DiagBase and SIMATIC IPC
SIMATIC IPC477D: The powerful embedded Panel PC – DiagMonitor)
maintenance-free with versatile configuration - High reliability and security of an embedded platform
Ready-to-run, complete solutions (software is already installed • An integral component of Totally Integrated Automation (TIA):
and preconfigured) for visualization and automation in connec- - Enhanced productivity, minimization of engineering costs,
tion with WinCC RT Advanced and/or WinAC RTX. reduction of lifecycle costs
• Embedded PC platform with extremely high industrial
compatibility for demanding tasks in the field of PC-based ■ Technical specifications
automation
See "PC-based Automation -> Industry PC -> Panel PC ->
• Maintenance-free (no rotating components such as fan and SIMATIC IPC477D"
hard disk)
• Rugged construction: the PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
■ Ordering data Article No.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC S7
Introduction
■ Overview
S7-400
S7 modular
2 S7-300
Embedded
Controller
S7-200
Software STEP 7
Professional V11.0
(TIA Portal)
Software Software Software
STEP 7-Micro/Win STEP 7 V5.5 STEP 7 V5.5
G_IK10_XX_10320v
Industrial Ethernet
PROFINET/Industrial Ethernet
System interfaces for SIMATIC S7
Introduction
■ Overview (continued)
• CP 1543-1 for SIMATIC S7-1500 Setup of Industrial Ethernet segments
- With security functionality (firewall and VPN) with SIMATIC modules with integrated switch
- With IT functionality
- For integrating the S7-1500 into IPv6 based networks. To set up Industrial Ethernet segments in a line or ring topology,
2
For the following communications services, an IP address all PROFINET communication modules offer integrated
according to IPv6 can be used: 100 Mbit/s switches with at least 2 RJ45 ports. The integration
- FETCH/WRITE access (CP is server) of the switch in the terminal devices allows the setup of very
- FTP server mode and FTP client mode with addressing flexible networks and saves cabling costs.
via program block
- E-mail transfer with addressing via program block
1000 Mbit/s
PC/IPC with
CP 1616/CP 1604
SIMATIC S7-400
with
CP 443-1 Advanced
Field Level
PROFINET
Industrial Ethernet
SCALANCE SCALANCE
X204IRT 100 Mbit/s X208
SIMATIC S7-300
with CP 343-1 Advanced
G_IK10_XX_10253
ET 200S ET 200S ET 200pro ET 200pro ET 200M
pGlGO{G
pGlGOmGvP
PROFINET/Industrial Ethernet
System interfaces for SIMATIC S7
Introduction
■ Overview (continued)
Ethernet
PROFINET IT communication Security Transport protocol Time Other
communication
PG/OP communication
2
S7 communication
Filetransfer server
Filetransfer client
TSend/TReceive
receive e-mail
ERP Connect
VPN (IP-Sec)
IRT real-time
IO Controller
send e-mail
Fetch/Write
SPI firewall
S7 routing
IO Device
IP routing
Receiver
Transfer
Sender
MRPD
SNMP
MRP
UDP
CBA
PRP
TCP
NTP
IPv4
IPv6
ISO
Hardware
SIMATIC SIMATIC
CP 243-1
S7-1200 S7-200
● ● ● ● ● ● ● ● ● ○
S7-1200 CPUs ● ● ● ● ● ● ● ● ● ●
CP 1243-1 ● ● ● ● ●2) ● ● ● ● ● ● ○ ●
CPU 1511-1 PN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
SIMATIC S7-1500
CPU 1513-1 PN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
CPU 1516-3 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
PN/DP
CP 1543-1 ● ● ● ● ● ● ●2) ● ● ● ● ● ● ● ● ● ● ○ ● ● ● ●
CP 343-1 Lean ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 Adv ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
CP 343-1 ERPC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○ ●
S7-400 PN CPUs ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
SIMATIC S7-400
CP 443-1 ● ● ● ● ● ○4) ● ● ● ● ● ● ● ● ● ●
CP 443-1 RNA ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
G_IK10_XX_10369
1) SMTP pass-through only ● applies
2) via S7-1200/1500 CPU ○ with reservations
3) Server (S) only
4) pass-through only
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1200
CP 1243-1
■ Overview ■ Benefits
• Data security
The CP 1243-1 has a large buffer for several thousand data
2
values. Downtimes in the transmission link can then be
bridged.
• Fully automatic time stamp
To enable subsequent and correct archiving of process data
in the control system, all data frames are assigned with a time
stamp at their place of origin.
• Fast and flexible data communication
Operators are therefore quickly provided with alarms, statuses
and values from the process, and they can influence process
control by entering commands or setpoints at any time.
• Simple and low-cost engineering
The cyclic or event-controller transfer of measurements,
setpoints or alarms can be implemented in only a few opera-
The CP 1243-1 communications processor is used for tions and without programming effort.
connecting a SIMATIC S7-1200 to the TeleControl Server Basic • Remote diagnostics
control center software via Ethernet, and for safe communication Saving of traveling and maintenance costs due to cost-
via IP-based networks. effective remote programming, diagnostics, control and
The CP has the following features: monitoring via the Internet
• Ethernet-based connection to TeleControl Server basic, e.g. • Industrial Security
via Internet Securing the system against unauthorized access by means
of
• Data transfer of measured values, control variables, or alarms - Central access protection for any devices within an
optimized for telecontrol systems automation cell, e.g. by means of authentication of the
• Automatic sending of alert emails network stations
• Data buffering of up to 64.000 values ensures a secure - Secure remote access via the Internet by means of data
database even with temporary connection failures encryption (VPN) and data integrity checking
• Secure communication via VPN connections based on IPSec
• Access protection by means of Stateful Inspection Firewall
■ Application
• Clearly laid out LED signaling for fast and easy diagnostics By using the CP 1243-1, the S7-1200 can be used as a remote
terminal unit (substation) in telecontrol applications. Typical uses
• Compact industrial enclosure in S7-1200 design for mounting include the collection of measured values in geographically
on a standard mounting rail widely distributed outdoor areas (level measurement for water
• Fast commissioning thanks to easy configuration using tanks) or centralized opening and closing of valves (oil/gas
STEP 7 transport in pipelines).
• Plants in water, wastewater or environmental sectors:
- Irrigation systems
- Drinking water supply
• Monitoring of power networks for consumption metering and
cost control
- District heating networks
- Wind farms
• Plants in the oil and gas sector
- Oilfield water injection
- Pipelines
Regardless of the telecontrol features of the CP, it can also be
used for purely security applications if the automation system is
to be connected securely to a higher-level IT network. This pro-
tects the SIMATIC S7-1200 against unauthorized access from an
Ethernet network. The CP 1243-1 allows safe access via a LAN
and allows data transfer between devices or network segments
to be protected from data manipulation/espionage.
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1200
CP 1243-1
The CP 1243-1 is a communication module for the S7-1200.
■ Design (continued) The module allows the S7-1200 to be connected as a remote
station to TeleControl Server basic in just a few steps.
Engineering control center Mobile Teleservice Engineering
Completely configurable application through
TIA Portal "data point configuration"
2 LAN Field PG
The introduction of the "data point configuration" in STEP 7
dispenses with all programming effort for transfer of data to the
control center.
Industrial Ethernet The data of the CPU relevant to the control center is selected via
user-friendly "item browsing" in STEP 7. In a clearly-arranged
Production menu, the data transfer parameters are then assigned to the
SIMATIC S7-1200 data points selected in this way. The cyclic or event-controller
with CP 1243-1 transfer of measurements, setpoints or alarms can thus be
implemented in only a few operations and without programming
effort.
PROFINET
Data backup
Industrial
Ethernet Data losses are prevented by the data buffering mechanisms
integrated in the product.
G_IK10_XX_10371
In the event of a connection failure, up to 64,000 time-stamped
values are buffered. When the connection returns, the buffered
SIMATIC SIMATIC values are automatically transferred to the control center in the
ET 200 TP700 S7-1200 right order.
E-mail alerting
Cell protection for SIMATIC S7-1200 with CP 1243-1 (Security Integrated) Alert e-mails can be configured for timely provision of stations'
states to service or maintenance personnel. If previously defined
■ Design events (such as threshold violation) should occur, application-
specific information is sent automatically by e-mail.
The CP 1243-1 offers all the advantages of the S7-1200 design:
Diagnostics
• Rugged, compact plastic enclosure
• Easily accessible connection and diagnostics elements, The CP 1243-1 offers comprehensive diagnostic options for a
protected by front flaps quick and informative analysis of the station status. Elementary
diagnostic information about the connection to the control center
• Simple mounting on the mounting rail of the S7-1200 is signaled directly via LEDs at the CP.
The CP 1243-1 DNP3 is plugged into the left-hand system Using STEP 7, comprehensive information can be retrieved,
bus interface of the S7-1200. Power is supplied directly via the such as connection history, buffer status, and the transferred
S7-1200. No additional wiring is necessary. Any required measured values.
modems or routers are connected via the Ethernet interface
on the underside of the module. Remote maintenance
For remote access from the control center to the substation, the
■ Function CP provides a remote maintenance port in parallel with process
operation. This ensures access for monitoring and program
changes.
Telecontrol center with
"TeleControl Server Basic" Interfaces
SCALANCE The CP 1243-1 has an Ethernet interface to connection to the
M812-1 control center. The S7-1200 can be connected via an existing
network or via other media by using additional routers (e.g.
SCALANCE M for Internet connection via DSL).
Power supply
Industrial Ethernet
Extra wiring for the CP power supply is not required. Power is
Tunnel
supplied directly via the backplane bus of the S7-1200.
SCALANCE
M812-1
Station Station
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1200
CP 1243-1
■ Technical specifications
Article No. 6GK7243-1BX30-0XE0 Article No. 6GK7243-1BX30-0XE0
Product-type designation CP 1243-1 Product-type designation CP 1243-1
Transmission rate Performance data
Transfer rate
• at the interface 1 10 … 100 Mbit/s
Performance data
open communication
2
• note like CPU
Interfaces
Performance data
Number of electrical connections S7 communication
• at interface 1 in accordance 1
with Industrial Ethernet Number of possible connections for
S7 communication
Design of electrical connection • note like CPU
• at interface 1 in accordance RJ45 port
with Industrial Ethernet Performance
data telecontrol
Supply voltage,
current consumption, power loss Suitability for use
• node station No
Type of supply voltage DC
• substation Yes
Supply voltage 1 5V • control center No
from backplane bus
Connection to the control center STEP 7 Basic/Professional V13
Resistive loss 1.25 W (TIA Portal) or higher + HSP
Permitted ambient conditions • note Connection to SCADA Systems via
TeleControl Server Basic
Ambient temperature • by means of a permanent supported
• for vertical installation -20 … +60 °C connection
during operating phase
• for horizontal installation -20 … +70 °C Protocol is supported
during operating phase • DNP3 No
• during storage -40 … +70 °C • IEC 60870-5 No
• during transport -40 … +70 °C Product function data buffering Yes
Relative humidity at 25 °C without 95 % if connection is aborted
condensation during operating • note 64.000 values
maximum Number of data points per station 200
Protection class IP IP20 maximum
Design, dimensions and weight Performance data
Teleservice
Module format Compact module S7-1200 single
width Diagnostic function online diagnostics Yes
with SIMATIC STEP 7
Width 30 mm
Height 110 mm Product function
Depth 75 mm • program download with Yes
SIMATIC STEP 7
Net weight 0.122 kg • remote firmware update Yes
Product properties, functions, Product functions management,
components general configuration
Number of modules Configuration software required STEP 7 Basic/Professional V13
• per CPU maximum 3 (TIA Portal) or higher + HSP
Product functions Security
Design of the firewall stateful inspection
Product function with VPN connection IPSec
Type of authentication procedure Preshared key (PSK),
with VPN connection X.509v3 certificates
Type of hashing algorithms MD5, SHA-1
with VPN connection
Number of possible connections 8
for VPN connection
Product function
• password protection No
for Web applications
• ACL - IP-based No
• ACL - IP-based for PLC/routing No
• switchoff of non-required services Yes
• blocking of communication via phys- No
ical ports
• log file for unauthorized access No
Product functions Time
Protocol is supported NTP No
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1200
CP 1243-1
2
connection of SIMATIC S7-1200 to
TeleControl Server Basic or for Industrial Ethernet with a rugged
secure connection via IP-based metal housing and integrated
networks insulation displacement contacts
for connecting Industrial Ethernet
Accessories FC installation cables;
180° cable outlet;
TeleControl Server Basic V3.0 for network components and
Software for 8 to 5 000 stations; CPs/CPUs with Industrial Ethernet
Single License for one installation; interface
OPC (UA) server for GPRS and • 1 pack = 1 unit 6GK1901-1BB10-2AA0
Ethernet/Internet communication • 1 pack = 10 units 6GK1901-1BB10-2AB0
with SIMATIC S7-1200 and
SIMATIC S7-200 (GPRS only); • 1 pack = 50 units 6GK1901-1BB10-2AE0
connection management to remote IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
stations; routing for connections (Type A)
between S7 stations;
German and English operator 4-core, shielded TP installation
interface; cable for connection to
for Windows 7 Professional IE FC Outlet RJ45/ IE FC RJ45 Plug;
32/64-bit + Service Pack 1 PROFINET-compatible;
Windows 7 Enterprise with UL approval;
32/64-bit + Service Pack 1 Sold by the meter;
Windows 7 Ultimate max. length 1 000 m;
32/64-bit + Service Pack 1 minimum order 20 m
Windows Server 2008 IE FC Stripping Tool 6GK1901-1GA00
32-bit + Service Pack 2
Windows Server 2008 R2 Standard Preadjusted stripping tool
64-bit Service Pack 1 for fast stripping of Industrial
• TeleControl Server Basic 8 V3 6NH9910-0AA21-0AA0 Ethernet FC cables
Connection management STEP 7 Basic Engineering
for 8 SIMATIC S7-1200 or Software V13 (TIA Portal)
S7-200 stations
• TeleControl Server Basic 32 V3 6NH9910-0AA21-0AF0 Target system:
Connection management SIMATIC S7-1200, S7-1500,
for 32 SIMATIC S7-1200 or S7-300, S7-400, WinAC
S7-200 stations Requirement:
Windows 7 Professional (64 bit),
• TeleControl Server Basic 64 V3 6NH9910-0AA21-0AB0 Windows 7 Enterprise (64 bit),
Connection management Windows 7 Ultimate SP1 (64 bit),
for 64 SIMATIC S7-1200 or Windows 8.1 (64 bit),
S7-200 stations Windows 8.1 Professional (64 bit),
• TeleControl Server Basic 256 V3 6NH9910-0AA21-0AC0 Windows 8.1 Enterprise (64 bit),
Connection management Windows Server 2008 R2 StdE
for 256 SIMATIC S7-1200 or (full installation),
S7-200 stations Windows Server 2012 StdE
• TeleControl Server Basic 1000 V3 6NH9910-0AA21-0AD0 (full installation)
Connection management Form of delivery:
for 1 000 SIMATIC S7-1200 or German, English, Chinese, Italian,
S7-200 stations French, Spanish
• TeleControl Server Basic 5000 V3 6NH9910-0AA21-0AE0 • STEP 7 Basic V13, Floating 6ES7822-0AA03-0YA5
Connection management License
for 5 000 SIMATIC S7-1200 or • STEP 7 Basic V13, Trial License 6ES7822-0AA03-0YA7
S7-200 stations • Upgrade STEP 7 Basic V12 to 6ES7822-0AA03-0YE5
• TeleControl Server Basic 6NH9910-0AA21-0GA0 STEP 7 Professional Basic V13,
UPGR V3 Floating License
Upgrade package from Version
V2.x to V3 for all license sizes Software Update Service
■ More information
Technical requirements/compatibility The CP 1243-1 can be configured with STEP 7 Basic/Profes-
sional V13 (TIA Portal) or higher.
A S7-1200 CPU with firmware version 3 is required to operate the
CP 1243-1. The TeleControl Server Basic V3 software package is required to
connect to the PCS 7/WinCC control center systems.
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CM 1542-1
■ Overview ■ Benefits
■ Application
The CM 1542-1 is used to connect the SIMATIC S7-1500 to
PROFINET networks. With its own processor, it relieves the CPU
of communications tasks and facilitates additional connections.
The CM 1542-1 provides communication options with:
• PGs/PCs,
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 • master computers
UDP • operator control and monitoring systems,
G_IK10_XX_10363
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CM 1542-1
■ Function
• PROFINET IO controller for the connection of up to 128 PN IO
devices SIMATIC S7-1500
with CM 1542-1
• Communications services of the interface:
- Open communication (TCP/IP, UDP):
2 Multicast with UDP
- PG/OP communication: inter-network with S7 routing
PROFINET
Industrial Ethernet
- S7 communication (client, server)
- IT communication (HTTP(S), e-mail)
nprXWXWZ][
SIMATIC S7-300
- Certified PROFINET IO controller with real-time properties with CP 343-1 Lean
(RT and IRT)
- IP addressing via DCP
ET 200SP
• Media redundancy (MRP);
- Within an Ethernet network with a ring topology, the Use as PROFINET IO controller for operating distributed I/O
CM supports the MRP media redundancy protocol as an on PROFINET
MRP manager and/or as an MRP client
• Diagnostics and network management:
- Extensive diagnostics functions for all modules in the Industrial Ethernet
Control Level
S7-1500 system
- Integration in network management systems through the SIMATIC S7-1500
support of SNMP V1 with CM 1542-1
• Time synchronization via NTP
Network seperation
• Security mechanisms:
- Access to the Web server via HTTPS
- Secure firmware update PROFINET
Field Level
nprXWXWZ]\
• Module replacement without programming device: ET 200S
All information can be stored on the memory card of the CPU.
ET 200SP
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CM 1542-1
■ Technical specifications
Article No. 6GK7542-1AX00-0XE0 Article No. 6GK7542-1AX00-0XE0
Product-type designation CM 1542-1 Product-type designation CM 1542-1
Transmission rate Performance data
Transfer rate
• at the interface 1 10 … 100 Mbit/s
Performance data
open communication
2
Interfaces Number of possible connections for
open communication via T-modules
Number of electrical connections • maximum 64
• at interface 1 in accordance 2 • comment depending on the system upper limit
with Industrial Ethernet
Data volume as user data per ISO on 65 536 byte
Design of electrical connection TCP connection for open communica-
• at interface 1 in accordance RJ45 port tion by means of T blocks maximum
with Industrial Ethernet
Number of Multicast stations 16
Supply voltage,
current consumption, power loss Performance data
S7 communication
Type of supply voltage DC
Number of possible connections for
Supply voltage 1 15 V S7 communication
from backplane bus • maximum 64
Relative symmetrical tolerance 3% • note depending on the system upper limit
at 15 V with DC
Performance data
Current consumption from backplane 0.22 A multi-protocol mode
bus at 15 V with DC typical
Number of active connections with 64
Resistive loss 3.3 W multiprotocol mode
Permitted ambient conditions Performance data
PROFINET communication
Ambient temperature as PN IO-Controller
• for vertical installation during operat- 0 … 40 °C
ing phase Product function PROFINET IO Yes
• for horizontal installation during op- 0 … 60 °C controller
erating phase Number of PN IO-Devices on 128
• during storage -40 … +70 °C PROFINET IO-Controller usable total
• during transport -40 … +70 °C Number of PN IO IRT-Devices on 64
• Comment - PROFINET IO-Controller usable
Relative humidity at 25 °C without 95 % Number of external PN IO lines 10
condensation during operating maxi- with PROFINET per rack
mum
Data volume
Protection class IP IP20 • as useful data for input variables as 8 Kibyte
Design, dimensions and weight PROFINET IO controller maximum
• as useful data for output variables 8 Kibyte
Module format Compact module S7-1500 single with PROFINET IO controller maxi-
width mum
Width 35 mm • as useful data for input variables per 1 433 byte
Height 142 mm PN IO device with PROFINET IO
controller maximum
Depth 129 mm
• as useful data for output variables 1 433 byte
Net weight 0.4 kg per PN IO device with PROFINET IO
controller maximum
Mounting type S7-1500 rail mounting Yes
• as user data for input variable per 256 byte
Product properties, functions, PN IO device per submodule as
components general PROFINET IO controller maximum
Number of modules • as user data for output variables per 256 byte
PN IO device per submodule as
• per CPU maximum 8 PROFINET IO controller maximum
• note depending on CPU type
Product functions management,
configuration
Product function MIB support Yes
Protocol is supported
• SNMP v1 Yes
• DCP Yes
• LLDP Yes
Configuration software required STEP 7 Professional V13 (TIA Portal)
or higher
Identification & maintenance function
• I&M0 - device-specific information Yes
• I&M1 - higher level designation/ Yes
location designation
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CM 1542-1
■ More information
You will find more information on SIMATIC S7-1500 at Offline version:
http://www.siemens.com/simatic-s7-1500 http://www.siemens.com/snst-download
The SIMATIC NET Selection Tool is available to assist in selecting You will find more information on the topic of Industrial Security
the right Industrial Ethernet switches as well as the configuration on the Internet at:
of modular variants: http://www.siemens.com/industrialsecurity
Online version:
http://www.siemens.com/snst
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
■ Application (continued)
Plant Security
2
Physical protection
Security management
Internet
SSC
Router
SCALANCE Central
S623 WEB Archiving
Server Server Internet SIMATIC Field PG
with SOFTNET
Security Client
SCALANCE
M812-1
pGl
SCALANCE S612 SCALANCE S623
Factory Automation
Production 1 Production 2 Production 3 Production 4 Production 5
SINUMERIK
SIMATIC SIMATIC 840D sl
SIMATIC S7-400 with S7-300 with
S7-1200 with S7-1500 with CP 443-1 CP 343-1
CSM 1277 CP 1543-1 Advanced Advanced
System Integrity
SIMATIC
S7-1200
Protection of the SIMATIC S7-1500 system from unauthorized access from the Industrial Ethernet network
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
■ Design ■ Function
The CP 1543-1 features all the advantages of the • Gigabit interface with an RJ45 connector with
SIMATIC S7-1500 design: 10/100/1 000 Mbps full/half duplex with autosensing
functionality
• Compact design:
• Communication services:
2
- One RJ45 jack for connecting to Industrial Ethernet;
automatic data rate detection using autosensing, - Open communication (TCP/IP, UDP, ISO):
autocrossing and autonegotiation; Multicast with UDP
the connection is made via the IE FC RJ45 Plug 180 with - PG/OP communication: inter-network with S7 routing
180° cable outlet or via a standard patch cable - S7 communication (client, server)
- The module is supplied with power via the integrated - IT communication:
backplane bus HTTP communication allows access to the Web server of the
- Three LEDs for displaying the operational and communica- S7-1500 system. With the CP 1543-1, HTTPS communication
tions status of the module and one LED under the front cover is also possible.
for the Ethernet interface to display ACTIVITY and LINK. The e-mail client function allows the sending of e-mails
directly from the user program.
• Simple installation: FTP communication allows program-controlled FTP client
The CP 1543-1 is mounted on the rail of the S7-1500 and communication.
connected to the adjacent modules by means of the bus Access to data blocks in the CPU via FTP server.
connectors. - IP address assignment using DHCP with IPv4 or by entering
• The CP 1543-1 can be operated without a fan; no backup the address directly in the engineering software
battery is required. STEP 7 Professional V12 or higher (TIA Portal)
• The module can be replaced without the need for a • Diagnostics and network management:
programming device. - Extensive diagnostics functions for all modules in the
S7-1500 system
- Integration in network management systems due to support
of SNMP V1/V3
• Security mechanisms:
- Access protection with firewall for filtering connections on
the basis of their IP and MAC addresses
- Secure communication via VPN (IPsec)
- Encrypted HTML pages using SSL (HTTPS)
- Secure file transfer (FTPS)
- Tap-proof transfer of network analysis information to the
network management system (SNMPv3)
- Secure transfer of the time of day (NTP)
• Configuration of all functions with STEP 7 Professional V13
(TIA Portal) or higher
• Module replacement without programming device:
All information can be stored on the memory card of the CPU.
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
■ Integration
Engineering Mobile Teleservice Engineering
Control Center
Field PG Field PG
Industrial Ethernet
SIMATIC S7-1500
with CP 1543-1
PROFIBUS DP PROFINET
Industrial Ethernet
SINAMICS SINAMICS
G_IK10_XX_10355
S7-1200 with ET 200S ET 200SP S7-300 with
CM 1242-5 CP 343-1 Lean
Connection to a higher-level network with network separation and access protection (firewall function)
Industrial Ethernet
SIMATIC SIMATIC
S7-1500 with S7-1500 with
CP 1543-1 CP 1543-1
S7-1200 with ET 200SP S7-300 with S7-1200 with ET 200SP S7-300 with
CM 1242-5 CP 343-1 Lean CM 1242-5 CP 343-1 Lean
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
■ Technical specifications
Article No. 6GK7543-1AX00-0XE0 Article No. 6GK7543-1AX00-0XE0
Product-type designation CP 1543-1 Product-type designation CP 1543-1
Transmission rate Performance data
Transfer rate
• at the interface 1 10 … 1 000 Mbit/s
S7 communication
Number of possible connections for
2
S7 communication
Interfaces • maximum 118
Number of electrical connections • note depending on the system upper limit
• at interface 1 in accordance 1 Performance data
with Industrial Ethernet multi-protocol mode
Design of electrical connection Number of active connections with 118
• at interface 1 in accordance RJ45 port multiprotocol mode
with Industrial Ethernet
Performance data
Supply voltage, IT functions
current consumption, power loss
Number of possible connections
Type of supply voltage DC • as client by means of FTP 32
Supply voltage 1 15 V maximum
from backplane bus • as server
Relative symmetrical tolerance 3% - by means of FTP maximum 16
at 15 V with DC - by means of HTTP maximum 4
• as e-mail client maximum 1
Current consumption from backplane 0.35 A
bus at 15 V with DC typical Amount of data as useful data 64 Kibyte
for e-mail maximum
Resistive loss 5.3 W
Product functions management,
Permitted ambient conditions configuration
Ambient temperature Product function MIB support Yes
• for vertical installation 0 … 40 °C
during operating phase Protocol is supported
• for horizontal installation 0 … 60 °C • SNMP v1 Yes
during operating phase • DCP Yes
• during storage -40 … +70 °C • LLDP No
• during transport -40 … +70 °C Configuration software required STEP 7 Professional V12 (TIA Portal)
Relative humidity at 25 °C without 95 % or higher
condensation during operating Identification & maintenance function
maximum
• I&M0 - device-specific information Yes
Protection class IP IP20 • I&M1 - higher level designation/ Yes
Design, dimensions and weight location designation
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-1500
CP 1543-1
2
to Industrial Ethernet via TCP/IP,
ISO and UDP and Security 4-core, shielded TP installation
functions; cable for connection to
1 x RJ45 interface with IE FC Outlet RJ45/IE FC RJ45 Plug;
10/100/1 000 Mbit/s; PROFINET-compatible;
electronic manual on DVD with UL approval;
sold by the meter;
Accessories max. length 1 000 m,
minimum order quantity 20 m
IE FC RJ45 Plug 180 2 x 2
IE FC TP Standard Cable GP 4 x 2
RJ45 plug-in connector for
Industrial Ethernet with a rugged 8-core, shielded TP installation
metal enclosure and integrated cable for connection to
insulation displacement contacts IE FC RJ45 Modular Outlet for
for connecting Industrial Ethernet universal applications; with UL
FC installation cables; approval;
with 180° cable outlet; sold by the meter;
for network components and max. quantity 1 000 m,
CPs/CPUs with Industrial Ethernet minimum order 20 m
interface • AWG22, for connection to 6XV1870-2E
• 1 pack = 1 unit 6GK1901-1BB10-2AA0 IE FC RJ45 Modular Outlet
• 1 pack = 10 units 6GK1901-1BB10-2AB0 • AWG24, for connection to 6XV1878-2A
• 1 pack = 50 units 6GK1901-1BB10-2AE0 IE FC RJ45 Plug 4 x 2
IE FC RJ45 Plug 4 x 2 IE FC stripping tool 6GK1901-1GA00
RJ45 plug connector for Industrial Preadjusted stripping tool for fast
Ethernet (10/100/1 000 Mbit/s) with stripping of the Industrial Ethernet
a sturdy metal enclosure and FC cables
integrated insulation displacement SCALANCE X204-2 6GK5204-2BB10-2AA3
contacts for connecting Industrial Industrial Ethernet Switch
Ethernet FC installation cables;
180° cable outlet; Industrial Ethernet Switches
for network components and with integral SNMP access,
CPs/CPUs with Industrial Ethernet Web diagnostics, copper cable
interface diagnostics and PROFINET diag-
• 1 pack = 1 unit 6GK1901-1BB11-2AA0 nostics for configuring line, star
• 1 pack = 10 units 6GK1901-1BB11-2AB0 and ring topologies;
four 10/100 Mbit/s RJ45 ports and
• 1 pack = 50 units 6GK1901-1BB11-2AE0 two FO ports
Industrial Ethernet Switch 6GK5308-2FL00-2AA3
SCALANCE X308-2
2 x 1000 Mbit/s multimode fiber-
optic cable ports (SC sockets), ,
1 x 10/100/1 000 Mbit/s RJ45 port,
7 x 10/100 Mbit/s RJ45 ports;
for glass fiber-optic cable (multi-
mode) up to max. 750 m
■ More information
You will find more information on SIMATIC S7-1500 at
http://www.siemens.com/simatic-s7-1500
The SIMATIC NET Selection Tool is available to assist in selecting
the right Industrial Ethernet switches as well as the configuration
of modular variants:
Online version:
http://www.siemens.com/snst
Offline version:
http://www.siemens.com/snst-download
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
Note:
For software ordering data, see page 2/584
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-200
CP 243-1
■ Overview ■ Benefits
■ Application
• The CP 243-1 communications processor is used to connect
S7-200 to Industrial Ethernet.
Communications processor for connecting a SIMATIC S7-200
to Industrial Ethernet networks • Distributed plants can be reached over telephone lines or
the Internet by using a router and simple diagnostics, signal or
The CP supports: user functions can be performed with the help of a web
• PG/OP communication browser. The CP 243-1 is especially suited for plant sections
• S7 communication where using PCs for permanent monitoring functions would
not be cost-effective.
• IT communication
• PC applications can access the data of an S7-200 via an
In addition, the CP 243-1 offers e-mail functions and user- S7 OPC server. In this way, process data can be easily
created web pages and thus optimally supports maintenance archived or further processed.
and quality assurance. The Internet functions such as FTP allow • SIMATIC S7-300 and S7-400 programmable controllers can
connection to the most diverse PC-based systems. communicate with a SIMATIC S7-200 with CP 243-1 over
Industrial Ethernet which means that the S7-200 can also be
used for more complex applications.
■ Design
The CP 243-1 offers all the advantages of the S7-200 design:
• Compact design in a rugged plastic enclosure
• Terminal strip for connecting the 24 V DC external supply
voltage
• LED status display
• Optional DIN rail mounting or direct wall mounting
• RJ45 socket for connection to Industrial Ethernet with
automatic data rate detection
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-200
CP 243-1
■ Function
The CP 243-1 is connected to Industrial Ethernet via an Web server;
RJ45 interface for 10/100 Mbit/s full/half duplex with HTML pages can be downloaded and viewed with standard
autosensing/autonegotiation and autocrossover function. browsers
■ Integration
S7-400
PC with application with CP 443-1
(e.g. WinCC, WinAC) Linux, DOS,
via OPC or UNIX, Mainframe
Internet browser via FTP S7-300 Notebook
with CP 343-1 Field PG
Advanced
Alarm via
SCALANCE email/sms Internet
S613
Router
Industrial Ethernet
Alarm via
PROFIBUS
CP 243-2 IO IO email/sms
S7-200 S7-200
G_IK10_XX_10287
Embedded System
EM 277 CP 243-1 CP 243-1
(e.g. nutrunner,
welding control ) Cell phone/PDA
AS-Interface via FTP
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-200
CP 243-1
■ Technical specifications
Article No. 6GK7243-1EX01-0XE0 Article No. 6GK7243-1EX01-0XE0
Product-type designation CP 243-1 Product-type designation CP 243-1
Transmission rate Product properties, functions,
Transfer rate at the interface 1 10 … 100 Mbit/s
components general
Number of modules
2
Interfaces
• per CPU maximum 1
Number of electrical connections
Performance data
• at interface 1 in accordance 1
with Industrial Ethernet Performance data
• for power supply 1 S7 communication
Design of electrical connection Number of possible connections for
• at interface 1 in accordance RJ45 port S7 communication
with Industrial Ethernet • maximum 8
• for power supply 3-pin termnal strip • with PG connections maximum 1
• with PG/OP connections maximum 8
Supply voltage,
current consumption, power loss Performance data
IT functions
Type of supply voltage DC
Number of possible connections
Supply voltage
• as client by means of FTP 1
• 1 from backplane bus 5V maximum
• external 24 V • as server by means of HTTP 4
Consumed current from external maximum
supply voltage at 24 V with DC • as e-mail client maximum 1
• typical 0.053 A Number of e-mails with 1 024 charac- 32
• maximum 0.06 A ters of e-mail client maximum
Resistive loss 1.5 W Number of access rights access 8
Permitted ambient conditions protections
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-200
CP 243-1
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Lean
■ Overview ■ Application
The CP 343-1 Lean is used to connect the SIMATIC S7-300 to
Industrial Ethernet networks. With its own processor, it relieves
the CPU of communications tasks and facilitates additional
connections.
The CP 343-1 Lean offers the communication options of the 2
S7-300 with
• PGs/PCs
• Master computers
• HMI devices
• Other SIMATIC S5/S7 systems
• PROFINET I/O Controllers
■ Design
The CP 343-1 Lean offers all the advantages of SIMATIC S7-300
system design:
• Compact design;
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 the rugged plastic casing features on the front:
UDP - Two RJ45 sockets for connecting to Industrial Ethernet with
automatic detection of transmission rate by means of
G_IK10_XX_10171
autosensing;
RJ45 sockets have an industry-compatible design
with additional retaining collars for connection of
Communications processor for connecting a SIMATIC S7-300 IE FC RJ45 Plug 145/180
to Industrial Ethernet networks, also as PROFINET IO Device. - Diagnostic LEDs for each switch port
The CP supports: - 2-pin plug-in terminal strip for connection of the 24 V DC
external supply voltage
• PG/OP communication
• Easy installation;
• S7 communication The CP 343-1 Lean is snap-mounted on the S7-300 DIN rail
• Open communication (SEND/RECEIVE) and connected to adjacent modules through the bus
• PROFINET communication connectors. There are no slot rules.
• The CP 343-1 Lean can be operated without a fan. A standby
■ Benefits battery is not required.
• In combination with IM 360/361, CP 343-1 Lean can also be
used in an expansion rack (ER).
■ Function
• High level of plant availability due to support of media • PROFINET interface with two RJ45 ports, 10/100 Mbit/s
redundancy (MRP) full/half duplex with autosensing and autocrossover function-
• Optimum support of maintenance through ality via 2-port switch
- Web-based diagnostics • Communication services via interface:
- Remote programming via WAN or a telephone network - Open communication (TCP/IP, UDP): Multicast for UDP
(ISDN) - PG/OP communication: inter-network with S7 routing
- Monitoring by means of IT network management tools - S7 communication (server only)
(SNMP) - PROFINET IO device
- Module replacement without programming device thanks to
saving of the configuration data on the CPU • Media redundancy (MRP):
- Within an Ethernet network with ring topology, the
• The capability of later connecting existing SIMATIC S7 CP supports the media redundancy procedure MRP
systems to Industrial Ethernet using the CP 343-1 Lean
ensures investment protection • Diagnostics and network management:
- Extensive diagnostic functions for all modules in the rack
- Integration into network management systems through the
support of SNMP V1
• Configuring of all functions with STEP 7, V5.4 or higher, or
STEP 7 Professional V11 (TIA Portal) or higher
• Module replacement without programming device thanks to
saving of the configuration data on the CPU
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Lean
jwGZ[ZTX wyvmpi|z
Protection class IP IP20
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Lean
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Lean
2
to Industrial Ethernet through
TCP/IP and UDP, Multicast,
S7 communication, open communi-
cation (SEND/RECEIVE),
FETCH/WRITE, PROFINET IO
Device, MRP, integrated 2-port
switch ERTEC, comprehensive
diagnostics facilities,
module replacement without PG,
SNMP, initial commissioning
over LAN;
with electronic manual on CD-ROM
Accessories
IE FC RJ45 Plug 145
RJ45 plug connector 2 x 2 for
Industrial Ethernet with a rugged
metal enclosure and integrated
insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables;
with 145° cable outlet
• 1 pack = 1 unit 6GK1901-1BB30-0AA0
• 1 pack = 10 units 6GK1901-1BB30-0AB0
• 1 pack = 50 units 6GK1901-1BB30-0AE0
IE FC TP Standard Cable GP 2 x 2 6XV1840-2AH10
(Type A)
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/IE FC RJ45 Plug;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1 000 m,
minimum order quantity 20 m
IE FC stripping tool 6GK1901-1GA00
Preadjusted stripping tool
for fast stripping of the Industrial
Ethernet FC cables
CSM 377 Compact Switch Module 6GK7377-1AA00-0AA0
Unmanaged switch for connection
of a SIMATIC S7-300 CPU,
ET 200M, and up to three further
nodes to Industrial Ethernet
operating at 10/100 Mbit/s;
4 x RJ45 ports;
external 24 V DC power supply,
LED diagnostics, S7-300 module
including electronic manual
on CD-ROM
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1
■ Overview ■ Application
The CP 343-1 is used for connecting the SIMATIC S7-300/
SINUMERIK 840D powerline to Industrial Ethernet networks.
With its own processor, it relieves the CPU of communications
tasks and facilitates additional connections.
The CP 343-1 permits communication of the S7-300 with: 2
• PGs/PCs
• Master computers
• HMI devices
• SIMATIC S7/C7 systems
• PROFINET IO devices
■ Design
The CP 343-1 has all the advantages of the SIMATIC S7-300
design:
• Compact design;
on the front, the rugged plastic housing features:
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 - Two RJ45 sockets for connection to Industrial Ethernet with
UDP automatic sensing of the data transmission rate by means of
Autosensing/Autonegotiation;
G_IK10_XX_10147
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1
■ Integration
wjTG GG
jwGX]X]GGjwGX]W[
2 GpvGj
SIMATIC S7-300
SIMATIC S7-300 with CP 343-1 or wyvmpul{
with CP 343-1 as CP 343-1 Lean
IO-Controller as IO-Device p
l
l{GYWW
plVwi plVhzT
l{ s s
YWWz wuGpv wuGpv
G
wyvmpul{ Code reading z^TZWWG
systems jwGZ[ZTXG
pGl sS
jwGZ[ZTXS
G IK10 XX 10221
nprXWXWY[^
jwGZ[ZTX wyvmpi|z
ET 200pro
IO-Devices
ET 200S IO Devices hzTp
IO-Devices
Line structure with CP 343-1 with integrated real-time switch Connection to higher-level network and PC-based system
as a PROFINET IO controller or IO device
wnVwj
G
z^TZWWG
jwGZ[ZTXG
pvTj
wyvmpul{
p
l
l{GYWW
plVwi plVhzT
l{ s s
YWWz wuGpv wuGpv
G
Code reading z^TZWWG
systems jwGZ[ZTXG
sS
jwGZ[ZTXS
nprXWXWYYY
jwGZ[ZTX wyvmpi|z
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1
■ Technical specifications
Article No. 6GK7343-1EX30-0XE0 Article No. 6GK7343-1EX30-0XE0
Product-type designation CP 343-1 Product-type designation CP 343-1
Transmission rate Performance data
Transfer rate at the interface 1 10 … 100 Mbit/s Performance data
open communication
2
Interfaces
Number of possible connections for 16
Number of electrical connections open communication by means of
• at interface 1 in accordance 2 SEND/RECEIVE blocks maximum
with Industrial Ethernet
• for power supply 1 Data volume
• as user data per ISO connection for 8 Kibyte
Design of electrical connection open communication by means of
• at interface 1 in accordance RJ45 port SEND/RECEIVE blocks maximum
with Industrial Ethernet • as user data per ISO on TCP con- 8 Kibyte
• for power supply 2-pin plug-in terminal strip nection for open communication by
means of SEND/RECEIVE blocks
Supply voltage, maximum
current consumption, power loss
• as user data per TCP connection for 8 Kibyte
Type of supply voltage DC open communication by means of
SEND/RECEIVE blocks maximum
Supply voltage
• as user data per UDP connection for 2 Kibyte
• 1 from backplane bus 5V open IE communication by means of
• external 24 V SEND/RECEIVE blocks maximum
Relative positive tolerance 20 % Number of Multicast stations 16
at 24 V with DC
Performance data
Relative negative tolerance 15 % S7 communication
at 24 V with DC
Number of possible connections for
Consumed current S7 communication
• from backplane bus 0,2 A • maximum 16
at 5 V for DC, typical
Performance data
• from external supply voltage
multi-protocol mode
at 24 V with DC
- typical 0.16 A Number of active connections with 32
- maximum 0.2 A multiprotocol mode
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1
2 PROFINET communication
as PN IO-Device Product function Web-based
diagnostics
Yes
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1
2
to Industrial Ethernet over ISO and
TCP/IP; PROFINET IO Controller or 4-core, shielded TP installation
PROFINET IO Device, MRP, cable for connection to
integrated 2-port switch ERTEC; IE FC Outlet RJ45/IE FC RJ45 Plug;
S7 communication, open communi- PROFINET-compatible;
cation (SEND/RECEIVE), FETCH/ with UL approval;
WRITE, with and without RFC 1006, sold by the meter;
multicast, DHCP, CPU clock syn- max. length 1 000 m,
chronization via SIMATIC procedure minimum order quantity 20 m
and NTP, diagnostics, SNMP, IE FC stripping tool 6GK1901-1GA00
access protection through IP
access list, initialization over LAN Preadjusted stripping tool
10/100 Mbit/s; for fast stripping of the Industrial
with electronic manual on DVD Ethernet FC cables
Accessories CSM 377 Compact Switch Module 6GK7377-1AA00-0AA0
IE FC RJ45 Plug 180 2 x 2 Unmanaged switch for connection
of a SIMATIC S7-300 CPU,
RJ45 plug connector for ET 200M, and up to three further
Industrial Ethernet with a rugged nodes to Industrial Ethernet
metal housing and integrated operating at 10/100 Mbit/s;
insulation displacement contacts 4 x RJ45 ports;
for connecting Industrial Ethernet external 24 V DC power supply,
FC installation cables; LED diagnostics,
180° cable outlet; S7-300 module including electronic
for network components and manual on CD-ROM
CPs/CPUs with Industrial Ethernet
interface SCALANCE X204-2 6GK5204-2BB10-2AA3
Industrial Ethernet Switch
• 1 pack = 1 unit 6GK1901-1BB10-2AA0
• 1 pack = 10 units 6GK1901-1BB10-2AB0 Industrial Ethernet Switches
with integral SNMP access,
• 1 pack = 50 units 6GK1901-1BB10-2AE0 Web diagnostics, copper cable
IE FC RJ45 Plug 145 diagnostics and PROFINET diag-
nostics for configuring line, star
RJ45 plug connector 2 x 2 for and ring topologies;
Industrial Ethernet with a rugged four 10/100 Mbit/s RJ45 ports and
metal enclosure and integrated two FO ports
insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables;
with 145° cable outlet
• 1 pack = 1 unit 6GK1901-1BB30-0AA0
• 1 pack = 10 units 6GK1901-1BB30-0AB0
• 1 pack = 50 units 6GK1901-1BB30-0AE0
Note:
For software ordering data, see page 2/584
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
■ Application (continued)
Operations level Operator Station
UMTS
SCALANCE
2
S623 Internet
DSL Modem
SCALANCE XR324-12M Field PG SCALANCE
M875
Control level
Industrial Ethernet SCALANCE X308-2M
SCALANCE
S612 SIMATIC S7-300
with CP 343-1
SIMATIC S7-400 Advanced
with CP 443-1
Advanced Engineering Operator
Station Station with
CP 1628
PROFINET/
Industrial Ethernet
Field level
SIMATIC SINAMICS SIMATIC
S7-300 with S120 ET 200S
nprXWXWY`^
CP 343-1
SIMATIC Lean
S7-1200
Secure VPN communication between SCALANCE S, SOFTNET Security Client and components with Security Integrated
■ Design
The CP 343-1 Advanced offers all the advantages of • Simple installation;
SIMATIC S7-300 system design: the CP 343-1 Advanced is mounted on the S7-300 mounting
• Compact design: rail and connected to adjacent modules by means of the bus
- Three RJ45 jacks for connecting to Industrial Ethernet via connector. There are no slot rules.
two independent interfaces; • The CP 343-1 Advanced can be operated without a fan;
one of which is a security jack for externally safeguarding the no backup battery is required.
network cell; • In combination with IM 360/361, the CP 343-1 Advanced can
automatic data rate detection by means of the autosensing, also be used in an expansion rack (ER).
autonegotiation and autocross functions;
the connection is made via the IE FC RJ45 Plug 180 with • The module can be replaced without the need for a
180° cable outlet or via a standard patch cable programming device
- 2-pin plug-in terminal strip for connection of the 24 V DC • C-PLUG (configuration plug) is included in the scope of
external supply voltage delivery as a removable storage medium (cannot be operated
- Diagnostics LEDs for indicating the operational and without C-PLUG)
communication status
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
■ Function ■ Integration
• Two separate interfaces (integrated network separation):
- Gigabit interface with an RJ45 connector with
10/100/1 000 Mbps full/half duplex with autosensing
functionality SIMATIC Industrial Ethernet
G_IK10_XX_10249
communication. ET 200S ET 200S
Access to data blocks via FTP server. PROFINET/Industrial Ethernet
• Communication services via PROFINET interfaces: if IRT is required, switches with IRT functionalities
- PROFINET IO controller and IO device with real-time (e.g. SCALANCE X204IRT) must be used
properties (RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via user Connection to a higher-level network with network separation
program and access protection (security functions)
• Media redundancy (MRP):
- Within an Ethernet network with a ring topology, the
CP supports the MRP media redundancy protocol as an wjTG GG
jwGX]X]GGjwGX]W[
MRP manager and as an MRP client GpvGj
• Diagnostics and network management:
- Extensive diagnostics functions for all modules in the rack
- Integration in network management systems due to support wyvmpul{
of SNMP V1/V3
• Security mechanisms: p
l
- Access protection by means of configurable IP access list
- Firewall for filtering connections on the basis of their IP/port l{GYWW
addresses
- Bandwidth limitation to avoid communication overload plVwi plVhzT
l{ s s
- VPN server and VPN client for tap-proof access to controllers YWWz wuGpv wuGpv
- Encrypted HTML pages using SSL (HTTPs) G
- Secure file transfer (FTPs) Code reading z^TZWWG
- Tap-proof transfer of network analysis information to the systems jwGZ[ZTXG
sS
network management system (SNMP) jwGZ[ZTXS
nprXWXWY[^
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
■ Integration (continued)
Management
Level
2
Database
server
Ethernet
Operations Level
SCALANCE SCALANCE
X414-3E X414-3E
Industrial Ethernet
Control Level
SCALANCE SCALANCE
IP camera X308-2 1000 Mbit/s XR324-12M 1000 Mbit/s
SCALANCE WinCC
X308-2M Server
with
1000 Mbit/s 1000 Mbit/s CP 1623
SIMATIC S7-400
with 1000 Mbit/s
CP 443-1 Advanced IPC with
Gigabit interface
SIMATIC S7-300 and CP 1616
with
CP 343-1 Advanced
Field Level
PROFINET 100 Mbit/s
Industrial Ethernet
G_IK10_XX_10270
ET 200S S7-300 with ET 200S ET 200pro Drives
CP 343-1 Lean
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
■ Technical specifications
Article No. 6GK7343-1GX31-0XE0 Article No. 6GK7343-1GX31-0XE0
Product-type designation CP 343-1 Advanced Product-type designation CP 343-1 Advanced
Transmission rate Performance data
2 Transfer rate
• at the interface 1 10 … 1 000 Mbit/s
Performance data
open communication
• at the interface 2 10 … 100 Mbit/s Number of possible connections for 16
Interfaces open communication by means of
SEND/RECEIVE blocks maximum
Number of electrical connections
Data volume
• at interface 1 in accordance 1
with Industrial Ethernet • as user data per ISO connection 8 Kibyte
for open communication
• at interface 2 in accordance 2 by means of SEND/RECEIVE blocks
with Industrial Ethernet maximum
• for power supply 1 • as user data per ISO on TCP 8 Kibyte
Design of electrical connection connection for open communication
by means of SEND/RECEIVE blocks
• at interface 1 in accordance RJ45 port
maximum
with Industrial Ethernet
• as user data per TCP connection 8 Kibyte
• at interface 2 in accordance RJ45 port
for open communication
with Industrial Ethernet
by means of SEND/RECEIVE blocks
• for power supply 2-pin plug-in terminal strip maximum
Design of the removable storage Yes • as user data per UDP connection 2 Kibyte
C-PLUG for open IE communication by
means of SEND/RECEIVE blocks
Supply voltage, maximum
current consumption, power loss
Number of Multicast stations 16
Type of supply voltage DC
Performance data
Supply voltage S7 communication
• 1 from backplane bus 5V
Number of possible connections for
• external 24 V S7 communication
Relative positive tolerance 20 % • maximum 16
at 24 V with DC
Performance data
Relative negative tolerance 15 % multi-protocol mode
at 24 V with DC
Number of active connections 48
Consumed current with multiprotocol mode
• from backplane bus 0.14 A Performance data
at 5 V for DC Typical IT functions
• from external supply voltage
at 24 V with DC Number of possible connections
- typical 0.48 A • as client by means of FTP 10
- maximum 0.62 A maximum
• as server
Resistive loss 14.7 W - by means of FTP maximum 2
Permitted ambient conditions - by means of HTTP maximum 4
Ambient temperature • as e-mail client maximum 1
• for vertical installation during operat- 0 … 40 °C Amount of data as useful data for e- 8 Kibyte
ing phase mail maximum
• for horizontal installation during op- 0 … 60 °C Storage capacity of user memory
erating phase
• as flash memory file system 28 Mibyte
• during storage -40 … +70 °C
• as RAM 30 Mibyte
• during transport -40 … +70 °C
Number of possible write cycles flash 100 000
Relative humidity at 25 °C without 95 % memory cells
condensation during operating
maximum Performance data
PROFINET communication
Protection class IP IP20 as PN IO-Controller
Design, dimensions and weight Number of PN IO-Devices on 128
Module format Compact module PROFINET IO-Controller usable total
Width 80 mm Number of PN IO IRT-Devices on 128
Height 125 mm PROFINET IO-Controller usable
Depth 120 mm Number of external PN IO lines 1
with PROFINET per rack
Net weight 0.8 kg
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 Advanced
Note:
For software ordering data, see page 2/584
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 ERPC
■ Overview ■ Application
The CP 343-1 ERPC (Enterprise Connect) is used for connecting
the SIMATIC S7-300 to Industrial Ethernet networks and to differ-
ent ERP or MES systems for vertical integration by means of a
firmware extension from the company ILS-Technology, to be
2 ordered separately. With its own processor, the module relieves
the CPU of communications tasks and facilitates additional
connections.
The CP 343-1 ERPC permits communication of the S7-300 with:
• PGs/PCs
• Master computers
• HMI devices
• SIMATIC S5/S7/C7 systems
• ERP or MES systems by means of database interface, e.g.
ORACLE, MySQL, MS-SQL, DB2, SAP by means of a firmware
extension from the company ILS-Technology, to be ordered
separately
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 ERPC
■ Function
• Gigabit interface with an RJ45 port with 10/100/1 000 Mbit/s • Diagnostics and network management:
full/half duplex with autosensing and autocrossover - Extensive diagnostic functions for all modules in the rack
functionality - Integration in network management systems through the
• Communication services: support of SNMP V1
- Communication services: Open communication
(TCP/IP, UDP)
• Security mechanisms:
- Access protection by means of configurable IP access list
2
- PG/OP communication: across networks by means of • Configuration
S7 routing - For the configuration of the database connection, see
- S7 communication (client, server) "deviceWISE Embedded Edition for SIMATIC S7".
- ERPC communication by means of a firmware expansion - Configuration of the automation functionality with STEP 7
from the company ILS-Technology, to be ordered separately. V5.5 or STEP 7 Professional V11
Connection to databases such as ORACLE, MySQL,
MS-SQL, DB2, SAP, and Message Queue systems. • Module replacement without programming device:
For further information on firmware expansion, refer to All information is stored on the C-PLUG
"deviceWISE Embedded Edition for SIMATIC S7".
■ Integration
Internet
Industrial Ethernet
G_IK10_XX_10284
Machine Machine Machine
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 ERPC
■ Integration (continued)
2 quality data
Production PC for
manufacturing control
PC with
CP 1623
SCALANCE
Industrial Ethernet
X308-2M
Data access using database functions
G_IK10_XX_10285
Machine Machine
■ Technical specifications
Article No. 6GK7343-1FX00-0XE0 Article No. 6GK7343-1FX00-0XE0
Product-type designation CP 343-1 ERPC Product-type designation CP 343-1 ERPC
Transmission rate Consumed current
Transfer rate at the interface 1 10 … 1 000 Mbit/s • from backplane bus 0.3 A
at 5 V for DC Typical
Interfaces • from external supply voltage
Number of electrical connections at 24 V with DC
• at interface 1 in accordance 1 - typical 0.16 A
with Industrial Ethernet - maximum 0.6 A
• for power supply 1 Resistive loss 14.7 W
Design of electrical connection Permitted ambient conditions
• at interface 1 in accordance RJ45 port
with Industrial Ethernet Ambient temperature
• for power supply 2-pin plug-in terminal strip • for vertical installation during 0 … 40 °C
operating phase
Design of the removable storage Yes • for horizontal installation during 0 … 60 °C
C-PLUG operating phase
Supply voltage, • during storage -40 … +70 °C
current consumption, power loss • during transport -40 … +70 °C
Type of supply voltage DC Relative humidity at 25 °C without 95 %
condensation during operating
Supply voltage maximum
• 1 from backplane bus 5V
• external 24 V Protection class IP IP20
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 ERPC
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-300
CP 343-1 ERPC
Note:
For software ordering data, see page 2/584
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1
■ Overview ■ Application
• The CP 443-1 is used to connect the SIMATIC S7-400 to
Industrial Ethernet networks. With its own processor, it relieves
the CPU of communications tasks and facilitates additional
connections.
The CP 443-1 offers communication options with 2
• PGs/PCs
• Host computers
• HMI systems
• SIMATIC S5/S7/C7 systems
• PROFINET IO devices
■ Design
The CP 443-1 features all the advantages of the SIMATIC S7-400
design:
• Compact design:
- Two RJ45 sockets for connecting to Industrial Ethernet;
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 automatic data rate detection by means of the autosensing/
UDP autocrossover function; the connection is made via the
G_IK10_XX_10152
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1
■ Integration (continued)
• Security mechanisms: • When using the blocks AG_SSEND (FC53), AG_SRECV
- Access protection by means of configurable IP access list (FC63), TSEND (FB63), TRCV (FB64), TCON (FB65) and
- Secure firmware update TDISCON (FB66), please note the following information:
- Plagiarism detection http://support.automation.siemens.com/WW/view/en/60037071
2 - Certification as per the Achilles Level II Standard
http://wurldtech.com/product_services/certify_educate/
• Module replacement without programming device:
All information can be stored on the CPU
certified_products/
• Configuration of all functions with STEP 7 V5.5 SP2;
configuration with STEP 7 Professional V11 only with a
limited range of functions of the predecessor CP 443-1
(6GK7 443-1EX20-0XE0) possible
■ Integration
z^T[WW
GjwG[[ZTX
G PG/PC
pvTj wnVwj Supervisor
G
wyvmpul{
PROFINET
p Industrial
l Ethernet
l{GYWW SCALANCE S
plVwi plVhzT
l{ s s
YWWz wuGpv wuGpv
G
Code reading z^TZWW
systems GjwGZ[ZTX
G_IK10_XX_10220
S7-400 S7-400 ET 200M
nprXWXWYX`
wyvmpi|z
PROFIBUS
IO Devices PC/IPC with CP 1616 hzTp
as IO-Device
Interfacing to higher-level network with CP 443-1 Line structure at the superordinated control level through
as PROFINET IO controller integrated 2-port switch
S7-400
with CP 443-1 SIMATIC S7-300
as IO-Controller
with CP 343-1
as IO Device
PROFINET
Industrial Ethernet
G_IK10_XX_10218
ET 200pro
IO Devices
ET 200S
IO Devices
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1
■ Technical specifications
Article No. 6GK7443-1EX30-0XE0 Article No. 6GK7443-1EX30-0XE0
Product-type designation CP 443-1 Product-type designation CP 443-1
Transmission rate Performance data
Transfer rate at the interface 1 10 … 100 Mbit/s Performance data
open communication
2
Interfaces
Number of possible connections 64
Number of electrical connections 2 for open communication
at interface 1 in accordance with by means of SEND/RECEIVE blocks
Industrial Ethernet maximum
Design of electrical connection RJ45 port Data volume
at interface 1 in accordance with
Industrial Ethernet • as user data per ISO connection 8 Kibyte
for open communication
Supply voltage, by means of SEND/RECEIVE blocks
current consumption, power loss maximum
Type of supply voltage DC • as user data per ISO on TCP con- 8 Kibyte
nection for open communication
Supply voltage 1 5V by means of SEND/RECEIVE blocks
from backplane bus maximum
Relative symmetrical tolerance 5% • as user data per TCP connection 8 Kibyte
at 5 V with DC for open communication
by means of SEND/RECEIVE blocks
Consumed current from backplane 1.4 A maximum
bus at 5 V for DC Typical • as user data per UDP connection 2 Kibyte
Resistive loss 8.6 W for open IE communication by
means of SEND/RECEIVE blocks
Permitted ambient conditions maximum
Ambient temperature Number of possible connections for 64
• during operating 0 … 60 °C open communication by means of T
blocks maximum
• during storage -40 … +70 °C
• during transport -40 … +70 °C Data volume as user data per ISO on 1 452 byte
• Comment - TCP connection for open communica-
tion by means of T blocks maximum
Relative humidity at 25 °C without 95 %
condensation during operating Performance data
maximum S7 communication
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1
2
to Industrial Ethernet through
TCP/IP, ISO and UDP; 4-core, shielded TP installation
PROFINET IO Controller, cable for connection to
MRP; integrated real-time switch IE FC Outlet RJ45/IE FC RJ45 Plug;
ERTEC with two ports; PROFINET-compatible;
2 x RJ-45 interface; with UL approval;
S7 communication, open communi- sold by the meter;
cation (SEND/RECEIVE) with max. length 1 000 m,
FETCH/WRITE, with and without minimum order quantity 20 m
RFC 1006, DHCP, SNMP V2, IE FC TP Standard Cable GP 4 x 2
diagnostics, multicast, access
protection over IP access list, 8-core, shielded TP installation
initialization over LAN 10/100 Mbit/s cable for universal applications;
with electronic manual on DVD with UL approval;
sold by the meter;
Accessories max. quantity 1 000 m,
IE FC RJ45 Plug 180 2 x 2 minimum order 20 m
• AWG22, for connection to 6XV1870-2E
RJ45 plug-in connector for IE FC RJ45 Modular Outlet
Industrial Ethernet with a rugged • AWG24, for connection to 6XV1878-2A
metal enclosure and integrated IE FC RJ45 Plug 4 x 2
insulation displacement contacts
for connecting Industrial Ethernet IE FC stripping tool 6GK1901-1GA00
FC installation cables;
with 180° cable outlet; Preadjusted stripping tool
for network components and for fast stripping of the Industrial
CPs/CPUs with Industrial Ethernet Ethernet FC cables
interface SCALANCE X204-2 6GK5204-2BB10-2AA3
• 1 pack = 1 unit 6GK1901-1BB10-2AA0 Industrial Ethernet Switch
• 1 pack = 10 units 6GK1901-1BB10-2AB0
Industrial Ethernet Switches
• 1 pack = 50 units 6GK1901-1BB10-2AE0 with integral SNMP access,
IE FC RJ45 Plug 4 x 2 Web diagnostics, copper cable
diagnostics and PROFINET
RJ45 plug connector for Industrial diagnostics for configuring line, star
Ethernet (10/100/1 000 Mbit/s) and ring topologies;
with a rugged metal housing and four 10/100 Mbit/s RJ45 ports and
integrated insulation displacement two FO ports
contacts for connecting Industrial
Ethernet FC installation cables; SCALANCE X308-2 6GK5308-2FL00-2AA3
180° cable outlet; Industrial Ethernet Switch
for network components and 2 x 1 000 Mbit/s multimode fiber-
CPs/CPUs with Industrial Ethernet optic cable ports (SC sockets),
interface 1 x 10/100/1 000 Mbit/s RJ45 port,
• 1 pack = 1 unit 6GK1901-1BB11-2AA0 7 x 10/100 Mbit/s RJ45 ports;
• 1 pack = 10 units 6GK1901-1BB11-2AB0 for glass fiber-optic cable (multi-
• 1 pack = 50 units 6GK1901-1BB11-2AE0 mode) up to max. 750 m
Note:
For software ordering data, see page 2/584
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
■ Application
The CP 443-1 Advanced is used to connect the SIMATIC S7-400 All the devices of an Ethernet network can be protected from
to Industrial Ethernet networks. With its own processor, it relieves unauthorized access. The CP 443-1 Advanced allows safe
the CPU of communication tasks and facilitates additional remote access over the Internet and allows data transfer be-
connections. tween devices or network segments to be protected from data
The CP 443-1 Advanced provides the following communication
manipulation/espionage. 2
options: PROFINET CBA components and security functionalities can be
• PGs/PCs used as an alternative.
• Master computers
• HMI systems
• SIMATIC S5/S7/C7 systems
• PROFINET I/O devices
• PROFINET CBA components
SCALANCE
S623 Internet
DSL Modem
SCALANCE XR324-12M Field PG SCALANCE
M875
Control level
Industrial Ethernet SCALANCE X308-2M
SCALANCE
S612 SIMATIC S7-300
with CP 343-1
SIMATIC S7-400 Advanced
with CP 443-1
Advanced Engineering Operator
Station Station with
CP 1628
PROFINET/
Industrial Ethernet
Field level
SIMATIC SINAMICS SIMATIC
S7-300 with S120 ET 200S
nprXWXWY`^
CP 343-1
SIMATIC Lean
S7-1200
Secure VPN communication between SCALANCE S, SOFTNET Security Client and components with Security Integrated
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
- Access protection by means of configurable IP access list
■ Design - Firewall for filtering connections on the basis of their IP/port
The CP 443-1 Advanced offers all the advantages of addresses
SIMATIC S7-400 system design: - Bandwidth limitation to avoid communication overload
- VPN server and VPN client for tap-proof access to controllers
• Compact design: - Encrypted HTML pages using SSL (HTTPs)
2
- Five RJ45 jacks for connecting to Industrial Ethernet via two - Secure file transfer (FTPs)
independent interfaces; one of which is a security socket for - Tap-proof transfer of network analysis information to the
externally safeguarding the network cell; automatic data rate network management system (SNMP)
detection by means of the autosensing and autocross - Translation of private and public IP addresses (NAT/NAPT)
function; the connection is made via the IE FC RJ45 Plug 180 - Secure transfer of the time of day (NTP V3)
with 180° cable outlet or via a standard patch cable - Secure firmware update
- Diagnostics LEDs for indicating the operational and commu- - Plagiarism detection
nication status - Certification as per the Achilles Level II Standard
• Simple installation; http://wurldtech.com/product_services/certify_educate/
the CP 443-1 Advanced is mounted on the S7-400 rack and certified_products/
connected to other modules by means of the backplane bus. • Configuration of all functions with STEP 7;
There are no slot rules. The security functions are configured using the Security
• The CP 443-1 Advanced can be operated without a fan. Configuration Tool (SCT), which is included in the scope of
• In combination with IM 460/461, the CP 443-1 Advanced can delivery for STEP 7 V5.5 SP2 HF1.
also be used in an expansion rack (ER). • Configuration with STEP 7 Professional V11;
• The module can be replaced without the need for a only possible with a limited range of functions of the prede-
programming device cessor CP 443-1 (6GK7 443-1GX20-0XE0), without security
functions and CBA.
• C-PLUG (configuration plug) is included in scope of delivery Version with security functions1) for TIA Portal in planning.
as a swap medium (cannot be operated without C-PLUG).
• When using the blocks AG_SSEND (FC53), AG_SRECV
(FC63), TSEND (FB63), TRCV (FB64), TCON (FB65) and
■ Function TDISCON (FB66), please note the following information:
• Two separate interfaces (integrated network separation): http://support.automation.siemens.com/WW/view/en/60037071
- Gigabit interface with one RJ45 port with • Module replacement without programming device:
10/100/1 000 Mbit/s, full/half-duplex with auto-sensing all information is stored on the C-PLUG (also file system for
capability IT functions)
- PROFINET interface with four RJ45 ports with 10/100 Mbit/s
full/half duplex with autosensing and autocrossover function-
ality via integrated 4-port switch
• Communications services via both interfaces:
- Open communication (TCP/IP and UDP):
Multicast with UDP, including routing between both inter-
faces
- PG/OP communication: inter-network with S7 routing
- S7 communication (client, server, multiplexing) including
routing between both interfaces
- S7-H-communication for S7-400-H-systems, now also
across network boundaries (ISO-on-TCP)
- IT communication:
HTTP communication permits access to process data via
user's own Web pages. HTTPS communication is also
possible with the CP 443-1 Advanced1).
The e-mail client function allows e-mails to be sent directly
from the user program.
FTP communication allows program-controlled FTP client
communication.
Access to data blocks via FTP server.
• Communication services via PROFINET interfaces:
- Certified PROFINET IO controller with real-time properties
(RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via user
program (e.g. for HMI)
• Media redundancy (MRP):
- Within an Ethernet network with a ring topology, the
CP supports the MRP media redundancy protocol as an
MRP manager and as an MRP client
• Diagnostics and network management:
- Comprehensive diagnostics functions for all modules in the
rack (including graphical diagnostics, e.g. topology)
- Integration in network management systems due to support
of SNMP V1/V3
• Security mechanisms:
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
■ Integration
pGl
zpth{pjGz^T[WW
wGwj
2
GjwG[[ZTXG
h mGwn zpth{pjGz^T[WW
GjwG[[ZTXG
uG h
SCALANCE SCALANCE
X208 X208 l{GYWWz
zpth{pjGz^TZWW
GjwGZ[ZTX
PC/IPC with
CP 1616 as
nprXWXWW^W
IO Device wyvmpul{ mGwn
nprXWXWW]`
wyvmpul{VpGl pGl
Gpy{GGSGGG
py{G l{GYWWz l{GYWWz
OUUGzjhshujlGYW[py{PG
GG
Connection to higher-level network Small independent local networks (e.g. within a machine or cell)
■ Technical specifications
Article No. 6GK7443-1GX30-0XE0 Article No. 6GK7443-1GX30-0XE0
Product-type designation CP 443-1 Advanced Product-type designation CP 443-1 Advanced
Transmission rate Permitted ambient conditions
Transfer rate Ambient temperature
• at the interface 1 10 … 1 000 Mbit/s • during operating 0 … 60 °C
• at the interface 2 10 … 100 Mbit/s • during storage -40 … +70 °C
Interfaces • during transport -40 … +70 °C
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
2 Performance data
open communication
PROFINET communication
as PN IO-Controller
Product function PROFINET IO Yes
Number of possible connections for 64 controller
open communication by means of
SEND/RECEIVE blocks maximum Number of PN IO-Devices on 128
PROFINET IO-Controller usable total
Data volume
• as user data per ISO connection for 8 Kibyte Number of PN IO IRT-Devices on 64
open communication by means of PROFINET IO-Controller usable
SEND/RECEIVE blocks maximum Number of external PN IO lines 4
• as user data per ISO on TCP con- 8 Kibyte with PROFINET per rack
nection for open communication by
means of SEND/RECEIVE blocks Data volume
maximum • as useful data for input variables 8 Kibyte
• as user data per TCP connection for 8 Kibyte as PROFINET IO controller
open communication by means of maximum
SEND/RECEIVE blocks maximum • as useful data for output variables 8 Kibyte
• as user data per UDP connection for 2 Kibyte with PROFINET IO controller
open IE communication by means of maximum
SEND/RECEIVE blocks maximum • as useful data for input variables 1 433 byte
per PN IO device
Number of possible connections for 64 with PROFINET IO controller
open communication by means of T maximum
blocks maximum
• as useful data for output variables 1 433 byte
Data volume as user data per ISO on 1 452 byte per PN IO device
TCP connection for open communica- with PROFINET IO controller
tion by means of T blocks maximum maximum
Performance data • as user data for input variable 240 byte
S7 communication per PN IO device per submodule
as PROFINET IO controller
Number of possible connections for maximum
S7 communication • as user data for output variables 240 byte
• maximum 128 per PN IO device per submodule
• with PG connections maximum 2 as PROFINET IO controller
• note when using several CPUs maximum
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 Advanced
2
SIMATIC S7-400 CPU to
Industrial Ethernet: 4-core, shielded TP installation
1 x 10/100/1 000 Mbit/s; cable for connection to
4 x 10/100 Mbit/s (IE SWITCH); IE FC Outlet RJ45/IE FC RJ45 Plug;
RJ45 ports; ISO; TCP; UDP; PROFINET-compatible;
PROFINET IO controller, with UL approval;
S7 communication; sold by the meter;
open communication (SEND/ max. length 1 000 m,
RECEIVE); S7 routing; minimum order quantity 20 m
IP configuration via DHCP/block; IE FC TP Standard Cable GP 4 x 2
IP Access Control List;
time synchronization; 8-core, shielded TP installation
expanded web diagnostics; cable for universal applications;
Fast Startup; PROFIenergy support; with UL approval;
IP routing; FTP; web server; e-mail; sold by the meter;
PROFINET CBA max. quantity 1 000 m,
• With security functionality 6GK7443-1GX30-0XE0 minimum order 20 m
(firewall and VPN) • AWG22, for connection to 6XV1870-2E
IE FC RJ45 Modular Outlet
Accessories • AWG24, for connection to 6XV1878-2A
IE FC RJ45 Plug 180 2 x 2 IE FC RJ45 Plug 4 x 2
RJ45 plug-in connector for IE FC stripping tool 6GK1901-1GA00
Industrial Ethernet with a rugged Preadjusted stripping tool
metal enclosure and integrated for fast stripping of the Industrial
insulation displacement contacts Ethernet FC cables
for connecting Industrial Ethernet
FC installation cables; SCALANCE X204-2 6GK5204-2BB10-2AA3
with 180° cable outlet; Industrial Ethernet Switch
for network components and
CPs/CPUs with Industrial Ethernet Industrial Ethernet Switches
interface with integral SNMP access,
Web diagnostics, copper cable
• 1 pack = 1 unit 6GK1901-1BB10-2AA0
diagnostics and PROFINET diag-
• 1 pack = 10 units 6GK1901-1BB10-2AB0 nostics for configuring line, star and
• 1 pack = 50 units 6GK1901-1BB10-2AE0 ring topologies;
four 10/100 Mbit/s RJ45 ports
IE FC RJ45 Plug 4 x 2 and two FO ports
RJ45 plug connector for Industrial Ethernet Switch 6GK5308-2FL00-2AA3
Industrial Ethernet SCALANCE X308-2
(10/100/1 000 Mbit/s) with a rugged
metal enclosure and integrated 2 x 1 000 Mbit/s multimode fiber-
insulation displacement contacts optic cable ports (SC sockets),
for connecting Industrial Ethernet 1 x 10/100/1000 Mbit/s RJ45 port,
FC installation cables; 7 x 10/100 Mbit/s RJ45 ports;
180° cable outlet; for glass fiber-optic cable
for network components and (multimode) up to max. 750 m
CPs/CPUs with Industrial Ethernet
interface
• 1 pack = 1 unit 6GK1901-1BB11-2AA0
• 1 pack = 10 units 6GK1901-1BB11-2AB0 Note:
• 1 pack = 50 units 6GK1901-1BB11-2AE0 For software ordering data, see page 2/584
■ More information
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 RNA
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 RNA
■ Application ■ Function
The CP 443-1 RNA enables communication in networks where A SIMATIC S7-400/S7-400H is connected to two parallel
extremely high plant availability is important. Industrial Ethernet networks via the two RJ45 connections of the
CP 443-1 RNA. The CP uses the parallel redundancy protocol in
It offers communication options with accordance with the IEC 62439-3 standard. It doubles the
2 • PGs/PCs
• Master computers
message frame and feeds it into the two connected networks.
The access point on the receiver side forwards the first arriving
message frame to the addressee. The frame arriving later is
• SIMATIC S5/S7/C7 systems discarded.
• Third-party systems
Two separate interfaces:
With the CP 443-1 RNA, an S7-400 station can be connected to • RNA interface with two RJ45 ports with 100 Mbit/s full duplex
a high-availability PRP network. with autonegotiation and autocrossover functionality
(no switching functionality) for connection to a PRP network
PG/PC/IPC with Server with • Ethernet interface with an RJ45 port with 10/100 Mbit/s full/half
SOFTNET-IE RNA SOFTNET-IE duplex with autonegotiation and autocrossover functionality
RNA There is only ever one interface active, no IP routing between
the interfaces;
communication per interface only possible to the CPU
Industrial in each case.
Ethernet
(LAN A)
The PRP functionality can be deactivated, and the independent
Ethernet interface can be activated as an alternative to the
Industrial RNA interface. Standard Industrial Ethernet communication is
Ethernet thus also possible with the CP. Only the communication service
(LAN B) is supported via the ISO transport protocol on the Ethernet
SIPROTEC SCALANCE interface, and all other services are deactivated. The CP is thus
X204RNA also suitable for applications that require qualification and can
manage with the restricted functionality. The qualification costs
can be reduced in this way.
SIMATIC PC Communication services
S7-400 with on the RNA interface (interface X2):
G_IK10_XX_10333
CP 443-1RNA
• Open communication (ISO, ISO on TCP, TCP/IP and UDP):
Multicast with UDP
• PG/OP communication: across networks by means of S7
routing
• S7 communication (ISO, ISO on TCP, client, server)
Connection of an S7-400 to a PRP network
• S7 H communication for S7-400 H systems beyond network
boundaries (ISO-on-TCP, ISO)
■ Design • Time synchronization by means of the SIMATIC procedure
The CP 443-1 RNA offers all the advantages of the and NTP
SIMATIC S7-400 system design: • IP address assignment via a simple PC tool
• Compact design: • Security mechanisms: Access protection by means of config-
- Three RJ45 jacks for connecting to Industrial Ethernet via urable IP access list
two independent interfaces, of which only one can ever be
active; Communication services
automatic data rate detection by means of the on the Ethernet interface (interface X1):
autonegotiation and autocross function; • Open communication (ISO only)
the connection is made via the IE FC RJ45 Plug 180 with • PG/OP communication: across networks by means of S7
180° cable outlet or via a standard patch cable. routing (ISO)
- Diagnostics LEDs for indicating the operational and commu-
nication status • S7 communication (ISO client only, server)
• Simple installation; Diagnostics and network management:
the CP 443-1 RNA is mounted on the S7-400 rack and • Extensive diagnostics functions of all modules in the rack via
connected to other modules by means of the backplane bus. Web diagnostics, integrated into STEP 7
There are no slot rules.
• Integration into network management systems through the
• The CP 443-1 RNA can be operated without a fan support of SNMP V1;
• In combination with the IM 460/461, the CP 443-1 RNA can the following MIBs are supported: MIBII, Automation MIB and
also be used in an expansion rack (ER) PRP-MIB (IEC-62439-3)
• The module can be replaced without the need for a Configuring
programming device of all functions with STEP 7 from V5.5 SP2 plus HSP
Module replacement possible without PG.
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 RNA
■ Integration
SCALANCE SCALANCE
2
X204RNA X204RNA
G_IK10_XX_10357
PRP communication with connected H systems to HMI station
Note:
With the SIMATIC NET DVD V12 it is possible to link SOFTNET
REDCONNECT and SOFTNET RNA; in this case, the
SCALANCE X switch can be omitted.
PRP communication
SCALANCE SCALANCE
XR-300 XR-300 EEC
HSR communication
SCALANCE SCALANCE
X204RNA X204RNA EEC
Industrial Ethernet
SCALANCE SCALANCE
X204RNA X204RNA
EEC
Protection device
IP camera with HSR 1)
G_IK10_XX_10344
Protection device
without HSR 1)
PC
For extended ambient
1)
High-Availability Seamless Redundancy Protocol conditions, e.g. EMC load
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 RNA
■ Technical specifications
Article No. 6GK7443-1RX00-0XE0 Article No. 6GK7443-1RX00-0XE0
Product-type designation CP 443-1 RNA Product-type designation CP 443-1 RNA
Transmission rate Performance data
2 Transfer rate
• at the interface 1 10 … 100 Mbit/s
Performance data
open communication
• at the interface 2 100 Mbit/s Number of possible connections for 64
Interfaces open communication by means of
SEND/RECEIVE blocks maximum
Number of electrical connections
Data volume
• at interface 1 in accordance 1
with Industrial Ethernet • as user data per ISO connection 8 192 byte
for open communication
• at interface 2 in accordance 2 by means of SEND/RECEIVE blocks
with Industrial Ethernet maximum
Design of electrical connection • as user data per ISO on TCP 8 192 byte
• at interface 1 in accordance RJ45 port connection for open communication
with Industrial Ethernet by means of SEND/RECEIVE blocks
maximum
• at interface 2 in accordance RJ45 port
with Industrial Ethernet • as user data per TCP connection 8 192 byte
for open communication
Supply voltage, by means of SEND/RECEIVE blocks
current consumption, power loss maximum
Type of supply voltage DC • as user data per UDP connection 2 048 byte
for open IE communication
Supply voltage 1 5V by means of SEND/RECEIVE blocks
from backplane bus maximum
Relative symmetrical tolerance 5% Number of possible connections 64
at 5 V with DC for open communication
by means of T blocks maximum
Consumed current from backplane 1.8 A
bus at 5 V for DC typical Data volume as user data per ISO 1 452 byte
on TCP connection for open commu-
Resistive loss 7.25 W
nication by means of T blocks
Permitted ambient conditions maximum
Ambient temperature Performance data
• during operating 0 … 60 °C S7 communication
• during storage -40 … +70 °C Number of possible connections
• during transport -40 … +70 °C for S7 communication
• maximum 128
Relative humidity at 25 °C without 95 %
condensation during operating • with PG connections maximum 2
maximum • note when using several CPUs
Protection class IP IP20 Performance data
multi-protocol mode
Design, dimensions and weight
Number of active connections 128
Module format Compact module S7-400 with multiprotocol mode
single width
Width 0.025 m
Height 0.29 m
Depth 0.21 m
Net weight 0.7 kg
Product properties, functions,
components general
Number of modules
• per CPU maximum 14
• note -
PROFINET/Industrial Ethernet
Communication for SIMATIC S7-400
CP 443-1 RNA
2
configuration SIMATIC S7-400/S7-400H CPU
to Industrial Ethernet
Product function MIB support Yes
Accessories
Protocol is supported SNMP v1 Yes
SCALANCE X-200RNA Industrial Ethernet network access points
Configuration software required STEP 7 V5.5 SP2 + HSP or higher
Industrial Ethernet network access
Product functions Diagnosis points with integrated SNMP
access, web diagnostics and
Product function Web-based Yes PROFINET diagnostics, for con-
diagnostics necting non-PRP-enabled terminal
Product functions Redundancy equipment to PRP networks;
incl. operating instructions,
Product function Parallel Yes Industrial Ethernet network manual
Redundancy Protocol (PRP) and configuration software
Product functions Security on CD-ROM;
with electrical and optical ports
Product function for glass multimode fiber optic
• ACL - IP-based Yes cables up to 5 km
• ACL - IP-based for PLC/routing Yes • SCALANCE X204RNA 6GK5204-0BA00-2KB2
with four 100 Mbit/s RJ45 ports
• switchoff of non-required services Yes
• SCALANCE X204RNA EEC 6GK5204-0BS00-3LA3
• blocking of communication Yes
with two 100 Mbit/s RJ45 ports
via physical ports
and two RJ45/SFP combo ports
Product functions Time • SCALANCE X204RNA EEC 6GK5204-0BS00-3PA3
with two 100 Mbit/s RJ45 ports
Product function
and two RJ45/SFP combo ports
• SICLOCK support Yes with PRP or HSR support
• pass on time synchronization Yes
SOFTNET-IE RNA
Protocol is supported NTP Yes
Software for connecting PCs to
PRP-enabled networks with
integrated SNMP, runtime software,
software and electronic manual
on CD-ROM, license key on USB
flash drive, Class A
SOFTNET-IE RNA V12
for 32/64-bit
Windows 7 Professional/Ultimate;
for Windows 2008 Server R2;
for 32/64-bit
Windows 8 Professional/Enterprise;
for Windows Server 2012
German/English
• Single license for one installation 6GK1711-1EW12-0AA0
SOFTNET-IE RNA V8.1
for 32-bit Windows XP;
German/English
• Single license for one installation 6GK1711-1EW08-1AA0
Software Update Service 6GK1711-1EW00-3AL0
for 1 year with automatic extension;
requirement:
Current software version
Note:
For software ordering data, see page 2/584
■ More information
You will find more information on the topic of Redundant Network
Access on the Internet at:
http://www.siemens.com/rna
PROFINET/Industrial Ethernet
Communication for SIMATIC S7
Software
PROFINET/Industrial Ethernet
Communication for SIMATIC S7
Software
PROFINET/Industrial Ethernet
System interfaces for PG/PC/IPC
Communication for PC-based systems
Introduction
■ Overview
CPs with an internal microprocessor
• Protocol software executes on the CP
• Free PC resources for applications
2 • Suitable for comprehensive applications
• Recommended for applications with HMI systems which have
high performance requirements, e.g. WinCC
• Recommended for large systems
(eight stations or more, e.g. SIMATIC)
• Constant communication throughput
• Can be used for redundant communication
• Use for PROFINET IO real-time applications
Software Hardware
(RT, IRT with CP 1616/CP 1604)
• Time synchronization
SIMATIC NET loaded over a network. This applies both to the local station on
Manual Collection which NCM PC or STEP 7 is installed and to the remote station
that is addressed over the network.
Note:
NCM PC does not contain a conversion function for LDBs that
were created using COML S7. Reconfiguration is necessary.
device
Type of
● applies
CP 1628
CP 1623
CP 1616
CP 1604
CP 1628
CP 1623
CP 1616
CP 1604
■ Overview (continued)
●
Security Integrated (Firewall/VPN) Connection to S7 backplane bus
●
●
PROFINET diagnosis Format module S7
Software
●
●
●
●
●
●
Hardware
●
●
●1) ●
●1) ●
Configuration with STEP 7 19“ type of construction
●
●
●
●
SNMP Rugged, compact housing
●
●
Ring redundancy incl. RM-functionality Modular design
Standby redundancy 10 Gigabit Ethernet
●
●
●
●
IRT capability Gigabit Ethernet
●
●
●
●
GVRP (Generic VLAN Registaration Protocol) LED diagnosis
SIMATIC environment
Rapid Spanning Tree Protocol)
Function overview of the communication modules with integral switch for SIMATIC PG/PC/IPC
GMRP (Generic Multicast Protocol) Signal contact
Broadcast/ Multicast/ Unicast Limiter Local display (SET pushbutton)
Broadcast blocking C-PLUG slot
IP Access List
Access Control List (MAC)
IEEE 802.1x (Radius)
Link Aggregation
Static Routing
RIPv2 (Dynamic Routing)
Siemens IK PI · 2015
OSPFv2 (Dynamic Routing)
G_IK10_XX_10319
2/587
System interfaces for PG/PC/IPC
Introduction
Communication for PC-based systems
PROFINET/Industrial Ethernet
2
© Siemens AG 2014
PROFINET/Industrial Ethernet
System interfaces for PG/PC/IPC
Communication for PC-based systems
Performance data
■ Overview
The following communications processors are available for Data throughput of Industrial Ethernet
connecting to the programming device or PC:
Comparisons between Layer-2 Ethernet cards and
• CPs with an internal microprocessor: CP 1613 A2/CP 1623/CP 1628 show the respective communi-
2
- CP 1616 (PCI) cations throughput.
- CP 1604 (PCI-104)
- CP 1613 A2 (PCI) This throughput varies between 0 and the maximum
- CP 1623 (PCIe) throughput for Layer-2 Ethernet cards with the corresponding
- CP 1628 (PCIe) software packages.
When the CP 1613 A2/CP 1623/CP 1628 is used with software
packages, the communications performance remains constantly
at a high level and ensures fast response times without any
variations.
Time
CP 1623/CP 1628
constant communication
performance
CP 1613 A2
Message/seconds
constant communication
performance
Layer 2 Ethernet cards
fluctuating communication
G_IK10_XX_10037
performance
■ More information
You can find more information on the Internet at:
http://www.siemens.com/simatic-net/ik-info
PROFINET/Industrial Ethernet
Communication for PC-based systems
Connection options to SIMATIC IPCs
■ Overview
The operating systems listed in the table refer exclusively to the tion of the relevant IPC for the operating system that is available
communication products specified! Please refer to the descrip- and has been released for that IPC.
Embedded Systems
Communication Communication
hardware software
Operating system environment of the
communication software
SIMATIC Industrial PC/
Field PG
Operation SIMATIC
system Indus-
2
trial-PC
Embedded Controller
SIMATIC S7 modular
SIMATIC IPC227D +
SIMATIC IPC427D +
Windows Embedded
Windows Embedded
SIMATIC IPC627D
SIMATIC IPC647D
SIMATIC IPC827D
SIMATIC IPC847D
SIMATIC IPC547E
Standard 7 + SP1
IPC 227D/277D
Standard 2009
Ultimate SP1
Field PG M4
IPC 277D
IPC 477D
SP1/2
SP2
CPs and software for Industrial Ethernet
CP 1613 A2 HARDNET-IE S7 ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(PCI 32 Bit)
HARDNET-IE S7 4)5) 4)5)
REDCONNECT 1) ● ● ● ● ● ● ● ● ○ ● ○ ● ● ●
S7 OPC Redundancy
for Industrial Ethernet ● ● ● ● ● ●
CP 1623 HARDNET-IE S7 ● ● ● ● ● ● ● ○ 5)
● ○ 5)
● ○ 5)
● ● ● ● ●
(PCIe x1)
HARDNET-IE S7
• • •
4)5) 4)5) 4)5) 4)5)
REDCONNECT 1) ● ● ● ● ● ● ● ○ ○ ○ ○ 5)
● ● ○
S7 OPC Redundancy
for Industrial Ethernet ● ● ● ●
CP 1628 HARDNET-IE S7 ● ● ● ● ○5) ● ○5) ● ○5) ● ● ● ● ●
(PCIe x1)
HARDNET-IE S7 4)5) 4)5) 4)5) 4)5)
REDCONNECT 1) ● ● ● ● ○ ● ○ ● ○ ● ○ 5)
● ● ○
S7 OPC Redundancy
for Industrial Ethernet ● ● ● ●
CP 1612 A2 SOFTNET-IE S7 ● ● ● ● ● ● ● ● ● ● ● ●
(PCI 32 Bit)
SOFTNET-IE S7 Lean ● ● ● ● ● ● ● ● ● ● ● ●
SOFTNET-IE PG ● ● ● ● ● ● ● ● ● ● ● ●
S7 OPC Redundancy
for Industrial Ethernet ● ● ● ●
SIMATIC SOFTNET-IE S7 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
PG/PC
with integral
Ethernet SOFTNET-IE S7 Lean ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
interface
SOFTNET-IE PG ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
S7 OPC Redundancy
for Industrial Ethernet
● ● ● ●
CPs and software for PROFINET
CP 1616 1)
•
6)7)
capacity NET products that you can view on the Internet pages shown below. not suitable
3) requires at least 2 PCI or 2 PCIe slots for redundant connection (4-way redundancy requires - for further details on XP embedded, see
4 free PCI or 4 PCIe slots!); hybrid configurations with CP 1613 A2 (PCI) and CP 1623 (PCIe) http://support.automation.siemens.com/WW/view/en/21661049
are possible, depending on PC expansion - further details on system requirements and operating environments can be
○ suitable under
certain conditions
4) without 4-way redundancy as there are only 2 slots found in the Readme file of the communication products on the SIMATIC
5) Observe restrictions for some PC versions: Number of slots and tolerable maximum heat loss/ NET PC Software DVD
power consumption per slot and in total - Updates and supplements to the catalog entries, as well as the above tables
6) integrated CP1616-compatible onboard 3-port PROFINET interface is optional can be viewed at
7) only with integrated interface http://www.siemens.com/simatic-net/ik-info
8) Portioning DL-16xx PNIO
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
■ Design ■ Function
• Industrial Ethernet (via "Connection Board for CP 1604") The CP 1604 can be operated as a PROFINET IO controller
- Ethernet real-time ASIC ERTEC 400 and/or PROFINET IO device that stores the process image (input
- 4 x RJ45 connection and output data) in the memory area on the CP. With simultane-
- Integral 4-port real-time switch for 10/100 Mbit/s Ethernet ous controller and device mode, only the controller or the device
- Half/full duplex
- Autosensing/Autocrossover/Autonegotiation
can be operated in IRT mode. High-performance data transfer
to and from the IO devices is performed autonomously by the
2
• PCI-104-Plus interface: CP 1604.
- PCI 2.2
- 32 bits Real-time
- 33 MHz or 66 MHz Support of real-time properties of PROFINET for RT and IRT.
- Installation through PCI standard mechanisms (Plug & Play) The real-time properties of the CP 1604 ensure extremely short
• Host interface/processor: cycle times with highly accurate clock-pulse rates.
- Dual-port RAM onboard Switching
- Flash for program memory onboard
- ARM 946 RISK processor (32-bit) onboard for prepro- According to the industry requirements, the 4-port real-time
cessing switch additionally permits the configuration of line topologies
• Interface for PROFIenergy: with spur lines and makes external switch components unneces-
- Connection option for user-specific interface for switching sary.
back on PC The switch function in RT mode is also available when the PC is
• Power supply: turned off thanks to the possibility of independently supplying an
- Operating voltage: 5 V through PCI-104 external voltage (via "Power Supply for CP 1604").
- Optional external 24 V DC supply for switch operation when
PC is switched off (through "Power Supply for CP 1604") Energy savings
• Size: Thanks to its support of PROFIenergy, CP 1604 allows for the
- PCI-104 format implementation of various energy-saving states during idle
times. By connecting an external power supply, the CP 1604 can
continue to communicate with the controller as a PROFIenergy
device, even while the PC is switched off. By connecting an
external hardware circuit, it is then possible to use this to reacti-
vate the PC via PROFIenergy mechanisms.
Software packages
DK-16xx PN IO development kit;
driver and IO-Base software for CP 1604 as PROFINET IO-
Controller and IO-Device under Linux in source code for transfer
to any PC-based operating systems with IO-Base interface for:
• PROFINET communication:
- PROFINET IO controller:
Connection of field devices to Industrial Ethernet with
PROFINET
- PROFINET IO device:
Link-up with a PROFINET IO controller through real-time
communication according to the PROFINET standard
• Access in isochronous mode to real-time data for
PROFINET over IRT;
extremely short cycle times with highly accurate clock-pulse
rates;
jitter accuracy, isochronous mode, and cycle time enable
high-performance motion control applications.
• Direct memory access to the process data;
the process data of the IO-Devices are always consistent.
The IO programming interface provides the PC programmer
with function calls for data transfer.
• The design of the interface not only permits fast access as a
PROFINET IO controller, but also easy transfer to other
operating system environments (e.g. VXWorks, QNX, RMOS,
RTX).
• The IO-Base interface for the PROFINET IO controller of the
CP 1604 is compatible with the interface for SOFTNET PN IO
• The CP 1604 is functionally compatible to the CP 1616
Using the Development Kit DK-16xx PN IO, the CP 1604 com-
munications processor can be integrated into any PC-based
operating system environment. The Development Kit contains
the driver and IO-Base source code required for this including
the transfer instructions and also the example code which
executes with SUSE Linux.
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
User interfaces
■ Integration
Programming interface through C library
• For applications that want to use the PROFINET IO-Controller PROFINET
or IO-Device functionality directly over C/C++, the IO-Base
interface can be used. This interface is of a similar design to Industrial Ethernet
2 the DP Base interface of PROFIBUS modules CP 5613 and
CP 5614. It is therefore possible to port existing PROFIBUS DP
master applications to PROFINET IO-Controller applications.
Diagnostics data
Extensive diagnostic options are available via STEP 7 or SNMP,
including: Switch Switch Switch
Field PG SCALANCE SCALANCE SCALANCE
• General diagnostics functions X208 X208 X208
• Connection diagnostics
• Diagnostics of the assigned PROFINET field devices
• Integration in network management systems through the
support of SNMP
Configuration
Configuration of the CP 1604 is performed with STEP 7/NCM PC,
V5.3 SP2 and higher. NCM PC is included with the module.
G_IK10_XX_30136
ET 200S ET 200S
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
■ Technical specifications
Article No. 6GK1160-4AA01 Article No. 6GK1160-4AA01
Product-type designation CP 1604 Product-type designation CP 1604
Transmission rate Performance data
Transfer rate at the interface 1 10 … 100 Mbit/s Performance data
PROFINET communication
2
Interfaces as PN IO-Controller
Number of electrical connections Software for PROFINET IO No
• at interface 1 in accordance 4 communication required
with Industrial Ethernet
• for power supply 1 Number of PN IO-Devices on 128
PROFINET IO-Controller usable total
Design of electrical connection
Number of PN IO IRT-Devices on 64
• at interface 1 in accordance RJ45 port via connection board PROFINET IO-Controller usable
with Industrial Ethernet
• of the backplane bus PCI-104 (32Bit) Data volume
• for power supply 4-pin terminal block • as useful data for input variables as 8 192 byte
via power supply board PROFINET IO controller maximum
• as useful data for output variables 8 192 byte
Supply voltage, with PROFINET IO controller
current consumption, power loss maximum
Type of supply voltage DC • as useful data for input variables 1 433 byte
per PN IO device with PROFINET IO
Type of power supply optional Yes controller maximum
external supply
• as useful data for output variables 1 433 byte
Supply voltage per PN IO device with PROFINET IO
• 1 from backplane bus 5V controller maximum
• external 24 V Performance data
• note optional external power supply and PROFINET communication
external supply voltage alternatively as PN IO-Device
via power supply board (optional
Amount of data
accessory)
• as useful data for input variables 1 433 byte
Relative symmetrical tolerance as PROFINET IO device maximum
• at 5 V with DC 5% • as useful data for input variables 1 433 byte
• at 24 V with DC 20 % as PROFINET IO device maximum
• as useful data for input variables 254 byte
Consumed current
for each sub-module under
• 1 from backplane bus 0.8 A PROFINET IO device
with DC maximum
• as useful data for input variables 254 byte
• from external supply voltage 0.3 A for each sub-module under
at 24 V with DC maximum PROFINET IO device
Resistive loss 4W • as useful data for the consistency 254 byte
• in switch mode maximum 4.1 W area for each sub-module
Design, dimensions and weight Configuration software required included in scope of delivery
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
2 Product function
• Web-based diagnostics Yes
approvals
Standard
• Port diagnostics Yes • for EMC 2004/108/EC
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1
Product functions switch
• for emitted interference EN 61000-6-3, EN 61000-6-4
Product feature switch Yes • for interference immunity EN 61000-6-1, EN 61000-6-2
Product function Verification of suitability
• switch-managed No • CE mark Yes
• for IRT PROFINET IO switch Yes • C-Tick Yes
Product functions Redundancy Accessories
Product function Accessories optional: Connection board for
• Ring redundancy Yes CP 1604, power supply board for
• Redundancy manager Yes CP 1604, HARDNET-IE DK
• Media Redundancy Protocol (MRP) Yes (development kit)
Note:
For software ordering data, see page 2/636
■ More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1616
■ Overview ■ Application
The CP 1616 enables SIMATIC PGs/PCs and PCs equipped with
a PCI slot to be connected to PROFINET IO.
The CP 1616 provides high-performance support for control
tasks on the PC (PC-based control, numeric control,
robot control). 2
With IRT (isochronous real-time), the CP is ideally suited to
time-critical applications that are in the range of isochronous
closed-loop control in the motion control sector.
The integrated 4-port switch supports low-cost system solutions
and the configuration of different topologies.
The CP 1616 provides SIMATIC programming devices/PCs and
industrial PCs with communication functions as:
• PROFINET IO controller and/or PROFINET IO device
The HARDNET-PN IO Development Kit enables integration of the
module into any operating systems.
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1616
User interfaces
■ Function
Programming interface through C library
The CP 1616 can be operated as a PROFINET IO controller and/
or PROFINET IO device that stores the process image (input and For applications that want to use the PROFINET IO-Controller or
output data) in the memory area on the CP. With simultaneous IO-Device functionality directly over C/C++, the IO-Base inter-
controller and device mode, only the controller or the device can face can be used. This interface is of a similar design to the
2 be operated in IRT mode. High-performance data transfer to and
from the IO devices is performed autonomously by the CP 1616.
DP Base interface of PROFIBUS modules CP 5613 and CP 5614.
It is therefore possible to port existing PROFIBUS DP master
applications to PROFINET IO-Controller applications.
Real-time
Diagnostics
Support of real-time properties of PROFINET for RT and IRT.
The real-time properties of the CP 1616 ensure extremely short Extensive diagnostic options are available via STEP 7 or SNMP,
cycle times with highly accurate clock-pulse rates. including:
• General diagnostics functions
Switching
• Connection diagnostics
According to the industry requirements, the 4-port real-time
switch additionally permits the configuration of line topologies • Diagnostics of the assigned PROFINET field devices
with spur lines and makes external switch components unneces- • Integration in network management systems through the
sary. support of SNMP
The switch function is also available in RT mode when the PC Configuration
is turned off thanks to the possibility of independently supplying
an external voltage. Configuration of the CP 1616 is performed with STEP 7/NCM PC,
V5.3 SP2 and higher. NCM PC is included with the module.
Energy savings
Thanks to support from PROFIenergy, it is possible to implement ■ Integration
various energy-saving states during idle times on the CP 1616.
Software packages wyvmpul{
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1616
■ Technical specifications
Article No. 6GK1161-6AA02 Article No. 6GK1161-6AA02
Product-type designation CP 1616 Product-type designation CP 1616
Transmission rate Performance data
Transfer rate at the interface 1 10 … 100 Mbit/s Performance data
PROFINET communication
2
Interfaces as PN IO-Controller
Number of electrical connections Software for PROFINET IO No
• at interface 1 in accordance 4 communication required
with Industrial Ethernet
• for power supply 1 Number of PN IO-Devices on 128
PROFINET IO-Controller usable total
Design of electrical connection
Number of PN IO IRT-Devices on 64
• at interface 1 in accordance RJ45 port PROFINET IO-Controller usable
with Industrial Ethernet
• of the backplane bus PCI (32 Bit 3,3 V/5 V UniversalKey Data volume
33/66 MHz) • as useful data for input variables 8 192 byte
• for power supply Low-voltage socket for hollow plug as PROFINET IO controller
3.5 mm (-) / 1.3 mm (+) maximum
• as useful data for output variables 8 192 byte
Supply voltage, with PROFINET IO controller
current consumption, power loss maximum
Type of supply voltage DC • as useful data for input variables 1 433 byte
per PN IO device with
Type of power supply optional Yes PROFINET IO controller maximum
external supply
• as useful data for output variables 1 433 byte
Supply voltage per PN IO device with
• 1 from backplane bus 5V PROFINET IO controller maximum
• external 6…9V Performance data
PROFINET communication
Relative symmetrical tolerance 5%
as PN IO-Device
at 5 V with DC
Amount of data
Consumed current
• as useful data for input variables 1 433 byte
• 1 from backplane bus 0.8 A
as PROFINET IO device maximum
with DC maximum
• as useful data for input variables 1 433 byte
• from external supply voltage
as PROFINET IO device maximum
- at 9 V with DC max. 0.65 A
• as useful data for input variables 254 byte
- at 9 V with DC max. 0.45 A for each sub-module under
Resistive loss 4W PROFINET IO device
• in switch mode maximum 4.1 W • as useful data for input variables 254 byte
for each sub-module under
Permitted ambient conditions PROFINET IO device
Ambient temperature • as useful data for the consistency 254 byte
area for each sub-module
• during operating 5 … 70 °C
• during storage -40 … +70 °C Number of submodules 64
• during transport -20 … +60 °C per PROFINET IO-Device
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1616
2 Product function
• Web-based diagnostics Yes
approvals
Standard
• Port diagnostics Yes • for EMC 89/336/EEC
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1
Product functions switch
• for emitted interference EN 61000-6-3, EN 61000-6-4
Product feature switch Yes • for interference immunity EN 61000-6-1, EN 61000-6-2
Product function switch-managed No Verification of suitability
Product function Yes • CE mark Yes
for IRT PROFINET IO switch • C-Tick Yes
Product functions Redundancy
Product function
• Ring redundancy Yes
• Redundancy manager Yes
• Media Redundancy Protocol (MRP) Yes
Note:
For software ordering data, see page 2/636
■ More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1612 A2
■ Overview ■ Application
The CP 1612 A2 supports the connection to Industrial Ethernet
(10/100/1 000 Mbit/s) for SIMATIC PG/PC and PCs with a PCI
slot. It is designed for use in an industrial environment and can
be operated with all SOFTNET for Industrial Ethernet and
SOFTNET PN IO packages. 2
■ Design
The CP 1612 A2 module (PCI card 32-bit; 33 MHz/66 MHz;
3.3 V/5 V Universal Key) is inserted directly into a
SIMATIC PG/PC or in a PC and requires a PCI slot.
• 1 x RJ45 connection with 10/100/1 000 Mbit/s (half/full duplex)
• Installation through PCI standard mechanisms (Plug & Play)
■ Function
The CP 1612 A2 offers the following accesses:
• Level 2:
interface for PC networks in the industrial environment
,62 7&3 31 053 23& 3*23 66 ,7
8'3 • Level 4 and Level 7:
economical access to Industrial Ethernet, e.g. to
*B,.B;;B
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1612 A2
■ Technical specifications
Article No. 6GK1161-2AA01 Article No. 6GK1161-2AA01
Product-type designation CP 1612 A2 Product-type designation CP 1612 A2
Transmission rate Performance data
2 Transfer rate at the interface 1 10 … 1 000 Mbit/s Performance data
open communication
Interfaces
Software for open communication Yes, SOFTNET-IE S7 (64 conn.) /
Number of electrical connections 1 by means of SEND/RECEIVE SOFTNET-IE S7 Lean (8 conn.)
at interface 1 in accordance required
with Industrial Ethernet
Number of possible connections 64
Design of electrical connection for open communication
• at interface 1 in accordance RJ45 port by means of SEND/RECEIVE
with Industrial Ethernet maximum
• of the backplane bus PCI (32 Bit 3.3 V/5 V UniversalKey
33/66 MHz) Performance data
S7 communication
Supply voltage,
current consumption, power loss Software for S7 communication Yes, SOFTNET-IE S7 (64 conn.) /
required SOFTNET-IE S7 Lean (8 conn.)
Type of supply voltage DC
Number of possible connections for 64
Supply voltage S7/PG communication maximum
• 1 from backplane bus 5V Performance data
• 2 from the backplane bus 12 V multi-protocol mode
Relative symmetrical tolerance Number of active connections 64
• at 5 V with DC 5% with multiprotocol mode
• at 12 V with DC 5% Number of configurable connections 207
Consumed current per PC station
• 1 from backplane bus 0.45 A Performance data
with DC maximum PROFINET communication
• 2 from backplane bus 0.5 A as PN IO-Controller
with DC maximum
Software for PROFINET IO Yes, SOFTNET-IE PN IO
Resistive loss 3.65 W communication required
Permitted ambient conditions Number of PN IO-Devices on 64
PROFINET IO-Controller usable total
Ambient temperature
• during operating 0 … 55 °C Number of PN IO IRT-Devices on 0
PROFINET IO-Controller usable
• during storage -10 … +70 °C
• during transport -10 … +70 °C Data volume
• as useful data for input variables 4 096 byte
Relative humidity at 25 °C without 95 % as PROFINET IO controller
condensation during operating maximum
maximum
• as useful data for output variables 4 096 byte
Protection class IP IP00 with PROFINET IO controller
maximum
Design, dimensions and weight
• as useful data for input variables 1 472 byte
Module format PCI per PN IO device with PROFINET IO
controller maximum
Width 18 mm
• as useful data for output variables 1 472 byte
Height 59 mm per PN IO device with PROFINET IO
Depth 140 mm controller maximum
Net weight 60 g Performance data
Product properties, functions, PROFINET CBA
components general Software for PROFINET CBA Yes, PN CBA OPC server
Number of plug-in cards 2 communication required
in the same design can be plugged Number of remote connection 228
in per PC station partners with PROFINET CBA
Number of connections 10 000
with PROFINET CBA total
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1612 A2
2
configuration 3.3 V/5 V universal keyed)
for connection to Industrial Ethernet
Product function MIB support No (10/100/1 000 Mbit/s)
with RJ45 interface,
Protocol is supported incl. driver for 32-bit Windows XP
• SNMP v1 Yes Professional SP2/3,
• SNMP v3 No 32/64-bit Windows 7,
• DCP Yes 2003 R2 Server SP2,
Vista Business/Ultimate SP1,
Configuration software Windows 2008 Server;
• required German/English
• for PROFINET CBA required Yes, SIMATIC iMAP Accessories
Standards, specifications, IE TP Cord RJ45/RJ45
approvals
TP cable 4 x 2
Standard with 2 RJ45 connectors
• for EMC 2004/108/EC
• 0.5 m 6XV1870-3QE50
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1,
UL 1950 •1m 6XV1870-3QH10
• for emitted interference EN 61000-6-3, EN 61000-6-4 •2m 6XV1870-3QH20
• for interference immunity EN 61000-6-1, EN 61000-6-2 •6m 6XV1870-3QH60
Verification of suitability • 10 m 6XV1870-3QN10
• CE mark Yes
• C-Tick Yes
Note:
For software ordering data, see page 2/636
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
■ Overview ■ Benefits
■ Design
• PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V universal key) with
microprocessor for connection of PG/PC to Industrial Ethernet The module CP 1613 A2 (PCI card with 32-bit microprocessor;
with 10/100 Mbit/s Autosensing/Autonegotiation 33 MHz/66 MHz; 3.3 V/5 V Universal Key) is inserted directly
into a SIMATIC PG/PC or into a PC and requires a short PCI slot.
• Communication services using It is capable of running in 64-bit PCI-X slots (PCI 2.2 and
- Open IE communication via TCP/IP and UDP) PCI-X-compatible).
- ISO transport protocol
- PG/OP communication Ports:
- S7 communication • 15-pin Sub-D socket for ITP
- Open communication (SEND/RECEIVE)
• RJ45 jack for twisted pair
• 15-pole ITP connection
• Automatic recognition and selection of the interface during
• RJ45 connection booting (ITP or RJ45)
• Time synchronization
The module is connected, for example,
• ISO and TCP/IP transport protocol onboard
• in the case of ITP via the ITP standard cable 9/15 to OSM/ESM
• SNMP-supported diagnostics
• in the case of TP via TP cord up to 10 m or via FastConnect
• The appropriate OPC server and configuration tools are system up to 100 m (IE FC RJ45 Plug and FC cables) to
included in the respective scope of supply of the communi- SCALANCE X or SCALANCE S
cation software
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
■ Function
User interfaces Software for open communication (SEND/RECEIVE)
OPC interface This interface is used for communication between
The OPC server included in the respective software package • PG/PC and SIMATIC S5
can be used as the standard programming interface for the
protocols S7 communication and open communication, in order
• PG/PC and SIMATIC S7 2
• PG/PC and PG/PC
to connect automation technology applications to OPC-compat-
ible Windows applications (Office, HMI systems, etc.) Open communication (SEND/RECEIVE) offers the following
services:
Programming interface through C library
• Management services
The programming interfaces for the S7 communication, PG/OP
communication, and open communication protocols for existing • Connection establishment services
applications are implemented as Dynamic Link Library (DLL) • Data transfer services
interfaces. These functionalities are a component part of the
You can find the released compilers in the Readme file HARDNET-IE S7 software product.
of the SIMATIC NET CD products at
http://www.siemens.com/automation/csi/net. Mode of operation
Protocols up to Level 4 (Transport) are processed autonomously
Software for PG/OP communication on the module.
This software makes it possible to program the S7 controllers via 16 MB of memory is available for this to support a large quanti-
Industrial Ethernet in conjunction with the STEP 7 engineering tative framework and reliable communication.
software.
Data is exchanged between the module and the host in master
It is included in all CP 1613 A2 software packages. mode. This means that the CP 1613 A2 accesses the physical
Software for S7 communication RAM of the host.
(HARDNET-IE S7 or S7-REDCONNECT) A Windows driver is responsible for transferring data between
The S7 interface allows PG/PC applications (e.g. WinCC) and the host system and the CP 1613 A2. The transmission rate to
user programs to access the SIMATIC S7 system components. Industrial Ethernet is detected and automatically switched over
This provides easy, flexible access to the data of the SIMATIC S7 (autosensing).
controller. The IT functionality is provided in combination with the Windows
S7 communication offers: software of the PC.
Administrative services Diagnostics
• Connection management Via SNMP all MIB-2 objects can be read out. This enables the
• Mini database current status of the Ethernet interfaces to be retrieved.
• Trace Configuration
Data transfer services • The S7 communication and open communication protocols
• Read/write variables are configured in STEP 7 or NCM PC.
• BSEND/BRECEIVE • A configuration tool is included in the scope of delivery of the
CP 1613 A2 software packages.
H-communication
For redundant S7 communication with a high availability
S7-400H system, the CP 1613/CP 1623/CP 1628 can be used in
connection with the S7-REDCONNECT software.
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
2
3.3 V/5 V universal keyed) for
Performance data connection to Industrial Ethernet
open communication (10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7/
Software for open communication by Yes, HARDNET-IE S7 (S7-1613)
S7-1613 and S7-REDCONNECT,
means of SEND/RECEIVE required
for operating system support
Number of possible connections for 120 see SIMATIC NET Software
open communication by means of
Accessories
SEND/RECEIVE maximum
Performance data IE TP Cord RJ45/RJ45
S7 communication TP cable 4 x 2
Software for S7 communication Yes, HARDNET-IE S7 (S7-1613) with 2 RJ45 connectors
required • 0.5 m 6XV1870-3QE50
•1m 6XV1870-3QH10
Number of possible connections
•2m 6XV1870-3QH20
• for S7/PG communication 120
maximum •6m 6XV1870-3QH60
• for optimized S7 communication 40 • 10 m 6XV1870-3QN10
maximum 1) also S5-compatible communication
Performance data
multi-protocol mode Note:
Number of active connections 120 For software ordering data, see page 2/636
with multiprotocol mode
Number of configurable connections 207
per PC station
Performance data
PROFINET CBA
Software for PROFINET CBA Yes, PN CBA OPC server
communication required
Number of remote connection part- 228
ners with PROFINET CBA
Number of connections 10 000
with PROFINET CBA total
Product functions management,
configuration
Product function MIB support Yes
Protocol is supported
• SNMP v1 Yes
• SNMP v3 No
• DCP Yes
Configuration software
• required included in scope of delivery of the
required software
• for PROFINET CBA required Yes, SIMATIC iMAP
Identification & maintenance function
• I&M0 - device-specific information Yes
• I&M1 - higher level Yes
designation/location designation
Product functions Redundancy
Software for redundancy function Yes, HARDNET-IE S7-REDCONNECT
required for communication with SIMATIC S7 H
systems
Product functions Time
Product function SICLOCK support Yes
Protocol is supported NTP No
Standards, specifications,
approvals
Standard
• for EMC 2004/108/EC
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1,
UL 1950
• for emitted interference EN 61000-6-3, EN 61000-6-4
• for interference immunity EN 61000-6-1, EN 61000-6-2
Verification of suitability
• CE mark Yes
• C-Tick Yes
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1623
■ Overview ■ Benefits
PC turned off
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1623
■ Application ■ Design
The CP 1623 makes it possible to connect to the Industrial Industrial Ethernet:
Ethernet (10/100/1 000 Mbit/s) for SIMATIC PG/PC and PCs with • 2 x RJ45 connection
PCI Express slot. Additional field devices can be flexibly
connected to the Industrial Ethernet via the integrated switch. • Integrated 2-port switch for 10/100/1 000 Mbit/s
(half/full/duplex)
• Autosensing/Autocrossover/Autonegotiation
2
PC/IPC with CP 1613 A2/
CP 1623/CP 1628 and
PG/PC slot:
HARDNET-IE S7 • PCI Express x1 card
• Can also be operated in PCIe x4-, x8- or x16 slots
• Installation via PCIe standard mechanisms (Plug & Play)
Power supply:
• Operating voltage 3.3 V/12 V via PCIe interface
Industrial • Optional external 12 - 24 V DC power supply for switch
Ethernet operation with PG/PC turned off
Size:
• Short PCIe format
S7-1200 with S7-1500 with
CP 1243-1 CP 1543-1
CM 1542-1
G_IK10_XX_10250
PC with
2 x CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE
S7-REDCONNECT
Industrial Ethernet
S7-400H
H CPU
G_IK10_XX_10048
in single mode
PROFIBUS ET 200M
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1623
■ Function
User interfaces Software for open communication (SEND/RECEIVE)
OPC interface This interface is used for communication between
• PG/PC and SIMATIC S5
2
The OPC server included in the respective software package
can be used as the standard programming interface for the pro- • PG/PC and SIMATIC S7
tocols S7 communication and open communication, in order to • PG/PC and PG/PC
connect automation technology applications to OPC-compatible
Windows applications (Office, HMI systems, etc.) Open communication (SEND/RECEIVE) offers the following
services:
Programming interface through C library
• Management services
The programming interfaces for the S7 communication,
PG/OP communication, and open communication protocols for • Connection establishment services
existing applications are implemented as Dynamic Link Library • Data transfer services
(DLL) interfaces. These functionalities are a component part of the
The released compilers can be found in the readme file HARDNET-IE S7 software product.
of the SIMATIC NET CD products at
http://www.siemens.com/automation/csi/net Mode of operation
Protocols up to Level 4 (Transport) are processed autonomously
Software for PG/OP communication on the module.
This software makes it possible to program the S7 controllers via The internal memory is available for this purpose and it also
Industrial Ethernet in conjunction with the STEP 7 engineering provides for a large quantity structure and high communication
software. reliability.
It is contained in all CP 1623 software packages. Data is exchanged between the module and the host in master
Software for S7 communication mode. This means that the CP 1623 accesses the physical RAM
(HARDNET-IE S7 or S7-REDCONNECT) of the host.
The S7 interface allows PG/PC applications (e.g. WinCC) and A Windows driver transfers the data between the host system
user programs to access the SIMATIC S7 system components. and the CP 1623. The transmission rate to Industrial Ethernet is
This provides easy, flexible access to the data of the SIMATIC S7 detected and automatically switched over (autosensing).
controller. The IT functionality is provided in combination with the Windows
S7 communication offers: software of the PC.
Administrative services Diagnostics
• Connection management All MIB-2 objects, for example, can be read out via SNMP.
• Mini database This enables the current status of the Ethernet interfaces to be
retrieved.
• Trace
Data transfer services Configuration
• Read/write variables • The S7 communication and open communication protocols
are configured in STEP 7 or NCM PC.
• BSEND/BRECEIVE
• A configuration tool is included in the scope of delivery of the
H-communication CP 1623 software packages.
For redundant S7 communication with a high availability
S7-400H system, the CP 1613/CP 1623/CP 1628 can be used
in connection with the S7-REDCONNECT software.
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1623
■ Technical specifications
Article No. 6GK1162-3AA00 Article No. 6GK1162-3AA00
Product-type designation CP 1623 Product-type designation CP 1623
Transmission rate Product properties, functions,
Transfer rate at the interface 1 10 … 1 000 Mbit/s
components general
Number of plug-in cards 4
2
Interfaces in the same design can be plugged
Number of electrical connections in per PC station
• at interface 1 in accordance 2 Number of modules note -
with Industrial Ethernet
• for power supply 1 Performance data
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1623
2
to Industrial Ethernet (10/100/
Product feature switch Yes 1 000 Mbit/s), with 2-port switch
(RJ45) via HARDNET-IE S7/S7-1613
Product function switch-managed No and S7-REDCONNECT. For operat-
Product function for No ing system support, see SIMATIC
IRT PROFINET IO switch NET Software
Product functions Redundancy Accessories
Software for redundancy function Yes, IE TP Cord RJ45/RJ45
required HARDNET-IE S7-REDCONNECT for TP cable 4 x 2
communication with SIMATIC S7 H with 2 RJ45 connectors
systems
• 0.5 m 6XV1870-3QE50
Product functions Time
•1m 6XV1870-3QH10
Product function SICLOCK support Yes •2m 6XV1870-3QH20
Protocol is supported NTP No •6m 6XV1870-3QH60
Standards, specifications, • 10 m 6XV1870-3QN10
approvals
Standard
• for EMC 2004/108/EC
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1,
UL 1950
• for emitted interference EN 61000-6-3, EN 61000-6-4
• for interference immunity EN 61000-6-1, EN 61000-6-2
Verification of suitability
• CE mark Yes
• C-Tick Yes
Note:
For software ordering dara, see page 2/636
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1628
■ Overview ■ Benefits
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1628
■ Application
The CP 1628 makes it possible to connect SIMATIC PG/PC and
PCs with PCI Express slot to the Industrial Ethernet (10/100/
1000 Mbps). Additional field devices can be flexibly connected
to the Industrial Ethernet via the integrated switch.
2
PC/IPC with CP 1613 A2/
CP 1623/CP 1628 and
HARDNET-IE S7 PC with 2 x CP 1628
and HARDNET-IE
S7-REDCONNECT
Industrial Ethernet
G_IK10_XX_10307
G_IK10_XX_10250
System configuration with CP 1613 A2/CP 1623/CP 1628 Example of redundant and secure network structure with CP 1628
and HARDNET-IE S7 and HARDNET-IE S7-REDCONNECT
SCALANCE
S623 Internet
DSL Modem
SCALANCE XR324-12M Field PG SCALANCE
M875
Control level
Industrial Ethernet SCALANCE X308-2M
SCALANCE
S612 SIMATIC S7-300
with CP 343-1
SIMATIC S7-400 Advanced
with CP 443-1
Advanced Engineering Operator
Station Station with
CP 1628
PROFINET/
Industrial Ethernet
Field level
SIMATIC SINAMICS SIMATIC
S7-300 with S120 ET 200S
nprXWXWY`^
CP 343-1
SIMATIC Lean
S7-1200
Secure VPN communication between SCALANCE S, SOFTNET Security Client and components with Security Integrated
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1628
Software for open communication (SEND/RECEIVE)
■ Design
This interface is used for communication between
Industrial Ethernet:
• PG/PC and SIMATIC S5
• 2 x RJ45 connection
• PG/PC and SIMATIC S7
• Integrated 2-port switch for 10/100/1 000 Mbps (half/full
2
duplex) • PG/PC and PG/PC
• Autosensing/Autocrossover/Autonegotiation Open communication (SEND/RECEIVE) offers the following
services:
PG/PC slot:
• Management services
• PCI Express x1 card
• Connection establishment services
• Can also be operated in PCIe x4, x8 or x16 slots
• Data transfer services
• Installation via PCIe standard mechanisms (Plug & Play)
These functionalities are a component part of the
Power supply: HARDNET-IE S7 software product.
• Operating voltage 3.3 V/12 V via PCIe interface
Security mechanisms:
• Optional external 12 - 24 V DC power supply for switch
operation with PG/PC turned off Integrated security mechanisms enable safeguarding of
important computer systems, including their associated data
Size: communication systems:
• Short PCIe format • Stateful Inspection Firewall for filtering connections on the
basis of their IP/port addresses
■ Function • Bandwidth limitation to avoid communication overload
User interfaces • Secure and encrypted access to controllers or remote access
over the Internet by means of VPN Server and VPN Client and
OPC interface checking of data integrity
The OPC server included in the respective software package • Tap-proof transmission of network analysis information to the
can be used as the standard programming interface for the pro- network management system (SNMP V3)
tocols S7 communication and open communication, in order to • Secure transfer of the time of day (NTP V3)
connect automation technology applications to OPC-compatible
Windows applications (Office, HMI systems, etc.) • Traceability by means of data logging on the basis of standard
IT mechanisms (Syslog)
Programming interface through C library
Mode of operation
The programming interfaces for the S7 communication, PG/OP
communication, and open communication protocols for existing Protocols up to Level 4 (Transport) are processed autonomously
applications are implemented as Dynamic Link Library (DLL) on the module.
interfaces. The internal memory is available for this purpose and it also
The released compilers can be found in the readme file provides for a large quantity structure and high communication
of the SIMATIC NET CD products at reliability.
http://www.siemens.com/automation/csi/net Data is exchanged between the module and the host in master
Software for PG/OP communication mode. This means that the CP 1628 accesses the physical RAM
of the host.
This software makes it possible to program the S7 controllers via
Industrial Ethernet in conjunction with the STEP 7 engineering A Windows driver transfers the data between the host system
software. and the CP 1628. The transmission rate to Industrial Ethernet is
detected and automatically switched over (autosensing).
It is contained in all CP 1628 software packages.
The IT functionality is provided in combination with the Windows
Software for S7 communication software of the PC.
(HARDNET-IE S7 or HARDNET-IE S7-REDCONNECT)
Diagnostics
The S7 interface allows PG/PC applications (e.g. WinCC) and
user programs to access the SIMATIC S7 system components. All MIB-2 objects, for example, can be read out via SNMP.
This provides easy, flexible access to the data of the SIMATIC S7 This enables the current status of the Ethernet interfaces to be
controller. retrieved.
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1628
■ Technical specifications
Article No. 6GK1162-8AA00 Article No. 6GK1162-8AA00
Product-type designation CP 1628 Product-type designation CP 1628
Transmission rate Design, dimensions and weight
2 Transfer rate at the interface 1 10 … 1 000 Mbit/s Module format PCI Express x1 (half length)
Interfaces Width 18 mm
Number of electrical connections Height 111 mm
• at interface 1 in accordance 2 Depth 167 mm
with Industrial Ethernet Net weight 0.124 kg
• for power supply 1
Product properties, functions,
Design of electrical connection components general
• at interface 1 in accordance RJ45 port Number of plug-in cards 4
with Industrial Ethernet in the same design can be plugged
• of the backplane bus PCI Express x1 in per PC station
• for power supply 2-pin terminal block
Performance data
Supply voltage,
current consumption, power loss Performance data
open communication
Type of supply voltage DC
Software for open communication by Yes, HARDNET-IE S7 (S7-1613)
Type of power supply optional Yes means of SEND/RECEIVE required
external supply
Number of possible connections for 120
Supply voltage open communication by means of
• 1 from backplane bus 3.3 V SEND/RECEIVE maximum
• 2 from the backplane bus 12 V Performance data
• external 24 V S7 communication
- minimum 10.5 V Software for S7 communication Yes, HARDNET-IE S7 (S7-1613)
- maximum 32 V required
Supply voltage note - Number of possible connections
Relative symmetrical tolerance • for S7/PG communication 120
maximum
• at 3.3 V with DC 9%
• for optimized S7 communication 64
• at 12 V with DC 8%
maximum
• at 24 V with DC 33 %
Performance data
Consumed current multi-protocol mode
• 1 from backplane bus 0.85 A
with DC maximum Number of active connections 120
with multiprotocol mode
• 2 from backplane bus 0.4 A
with DC maximum Number of configurable connections 207
• from external supply voltage per PC station
- at 12 V with DC max. 0.55 A Performance data
- at 24 V with DC maximum 0.3 A PROFINET CBA
Resistive loss 7.6 W Software for PROFINET CBA Yes, PN CBA OPC server
communication required
Resistive loss in switch mode 7.2 W
maximum Number of remote connection 228
partners with PROFINET CBA
Permitted ambient conditions
Number of connections 10 000
Ambient temperature with PROFINET CBA total
• during operating 5 … 55 °C
• during storage -20 … +60 °C Product functions management,
configuration
• during transport -20 … +60 °C
Product function MIB support Yes
Relative humidity at 25 °C without 95 %
condensation during operating Protocol is supported
maximum • SNMP v1 Yes
Protection class IP IP00 • SNMP v3 Yes
• DCP Yes
Configuration software
• required included in scope of delivery of
required software
• for PROFINET CBA required Yes, SIMATIC iMAP
Identification & maintenance function
• I&M0 - device-specific information Yes
• I&M1 - higher level Yes
designation/location designation
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1628
2
to Industrial Ethernet (10/100/
Product feature switch Yes 1 000 Mbit/s), with 2-port switch
(RJ45) and integrated security (fire-
Product function wall, VPN) via HARDNET-IE S7 and
• switch-managed No S7-REDCONNECT. For operating
• for IRT PROFINET IO switch No system support, see SIMATIC NET
Software
Product functions Redundancy
Accessories
Software for redundancy function Yes, HARDNET-IE S7-REDCONNECT
required for communication with SIMATIC S7 H IE TP Cord RJ45/RJ45
systems
TP cable 4 x 2
Product functions Security with 2 RJ45 connectors
Design of the firewall stateful inspection • 0.5 m 6XV1870-3QE50
•1m 6XV1870-3QH10
Product function IPSec •2m 6XV1870-3QH20
with VPN connection
•6m 6XV1870-3QH60
Type of encryption algorithms AES-256, AES-192, AES-128, • 10 m 6XV1870-3QN10
with VPN connection 3DES-168, DES-56
Type of authentication procedure Preshared key (PSK), Note:
with VPN connection X.509v3 certificates
For software ordering data, see page 2/636
Type of hashing algorithms MD5, SHA-1
with VPN connection
Number of possible VPN tunnels 64
■ More information
Number of possible connections You will find more information on the topic of Industrial Security
for S7 communication on the Internet at:
• via ISO and VPN 64 http://www.siemens.com/industrialsecurity
with S7-REDCONNECT maximum
• via TCP and VPN 120
with S7-REDCONNECT maximum
Number of available IP addresses 16
with VPN connection maximum
Product functions Time
Product function SICLOCK support Yes
Protocol is supported NTP Yes
Standards, specifications,
approvals
Standard
• for EMC 2004/108/EC
• for safety of CSA and UL CAN/CSA C22.2 & UL 60950-1,
UL 1950
• for emitted interference EN 61000-6-3, EN 61000-6-4
• for interference immunity EN 61000-6-1, EN 61000-6-2
Verification of suitability
• CE mark Yes
• C-Tick Yes
PROFINET/Industrial Ethernet
Communication for PC-based systems
HARDNET-IE S7-REDCONNECT
■ Overview ■ Benefits
PC with
2 x CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE
2 Industrial Ethernet
S7-REDCONNECT • Protects against communication failures arising from a fault in
the double bus or in redundant rings
• Simplifies communication between a PC application and the
S7-400H SIMATIC S7-400H system
• Secures the investment thanks to the use of existing applica-
tions and flexible application options
• No additional programming overhead for the PC and in
H systems
H CPU
G_IK10_XX_10048
in single mode • Increases the availability of the PC application (e.g. PCS 7)
thanks to redundant Layer 2 or Layer 3 communication
PROFIBUS ET 200M
■ Application
The HARDNET-IE S7-REDCONNECT software package con-
System configuration for S7-REDCONNECT nects the SIMATIC S7-400H with applications on the PC such as
WinCC.
ISO TCP/ PN MRP OPC PG/OP S7/S5 IT
UDP A redundant Industrial Ethernet is typically used. The software
package can also be used if SIMATIC H systems are operated
G_IK10_XX_10184
on non-redundant networks.
Combined operation of redundant and single systems is also
• For connecting PCs over redundant Industrial Ethernet to the possible.
SIMATIC S7-400H
• Protected from communication failures arising from a fault in ■ Design
the double bus or in redundant rings
The following components are required to design a
• For redundant Layer 2 or Layer 3 Industrial Ethernet SIMATIC H system with PC connection
• Can also be implemented in non-redundant networks PC with:
• No additional programming overhead for the PC and in • up to four CP 1613 A2/CP 1623/CP 1628 and
H systems HARDNET-IE S7-REDCONNECT to connect the PC to
• The appropriate OPC server and configuration tools are Industrial Ethernet with ISO or ISO-on-TCP protocol
included in the scope of supply of the respective communi-
cation software S7-400H with:
• Enhanced redundancy over 4-way communication • CP 443-1 to connect the S7-400H to Industrial Ethernet with
(STEP 7 V5.1 + SP4 and higher) ISO or ISO-on-TCP protocol
• STEP 7 V5.0 to V5.5 for configuring
PROFINET/Industrial Ethernet
Communication for PC-based systems
HARDNET-IE S7-REDCONNECT
■ Function
• HARDNET-IE S7-REDCONNECT contains the functional User interfaces
scope of the HARDNET-IE S7 software package (S7-commu-
nication, open communication and PG/OP communication) as OPC interface
well as additional redundant communication over S7 connec- The OPC server included in the respective software package
tions. No additional license is required for HARDNET-IE S7.
• Open communication
can be used as the standard programming interface for the S7
communication and open communication protocols in order to
2
connect automation technology applications to OPC-compatible
• Time synchronization Windows applications such as Office, HMI systems, etc.
• Existing Windows applications can be used
Configuration
• Services for monitoring the redundant communication
• H-connections are configured and engineered using STEP 7
• Diagnostic tool for visualizing the communication status (V5.0 to V5.5)
• Simple redundancy over 2-way communication (STEP 7 V5.0
SP2 and higher)
• Enhanced redundancy over 4-way communication (STEP 7
V5.1 + SP4 and higher)
Fault-tolerant S7 communication is carried out via a standard
connection and a standby connection. These are monitored dur-
ing operation and switched in the event of a fault. With HARD-
NET-IE S7-REDCONNECT, these remain hidden from the PC ap-
plication.
Fault detection, changeover (if required), communication moni-
toring, and synchronization are all invisible to the application.
The application, e.g. WinCC, communicates with both subunits
of the S7-400H as with an S7-CPU.
■ Integration
PC
with HARDNET-IE S7-REDCONNECT
and 2 x CP 1613 A2 / CP 1623 / CP 1628
SCALANCE SCALANCE
XM416-4C XM416-4C
S7-300 S7-1500
SCALANCE SCALANCE
X204-2 X204-2
100 Mbit/s
Industrial Ethernet
10/100 Mbit/s
S7-400
SCALANCE SCALANCE
X204-2 X204-2
S7-400 S7-400
G_IK10_XX_10053
Note:
The optical ring can also be
implemented optionally as an H system H system
electrical ring
PROFINET/Industrial Ethernet
Communication for PC-based systems
HARDNET-IE S7-REDCONNECT
2
incl. S7 OPC server, from S7-1613 to S7 REDCONNECT,
HARDNET-IE S7, runtime software, Single License for one installation,
software and electronic manual on runtime software, software
CD-ROM, license key on USB stick, and electronic manual on CD-ROM,
Class A; license key on USB stick, Class A;
For CP 1613 A2, HARDNET-IE S7-REDCONNECT 6GK1716-0HB12-0AC0
CP 1623, CP 1628 PowerPack V12
HARDNET-IE S7-REDCONNECT for 32/64-bit:
V12 Windows 7 Professional/Ultimate;
for 64-bit:
for 32/64-bit: Windows 2008 Server R2;
Windows 7 Professional/Ultimate; for 32/64-bit Windows 8 Pro;
for 64-bit: for Windows Server 2012
Windows 2008 Server R2 German/English;
for 32/64 Bit Windows 8 Pro;
for Windows Server 2012 CP 1613 A2 6GK1161-3AA01
German/English communications processor
• Single License for one installation 6GK1716-0HB12-0AA0 PCI card (32-bit, 33 MHz/66 MHz;
Software Update Service 6GK1716-0HB00-3AL0 3.3 V/5 V universal keyed)
for connection to Industrial Ethernet
For one year (10/100 Mbit/s) with ITP and RJ45
with automatic extension; connection over HARDNET-IE S7
requirement: and S7-REDCONNECT,
current software version for operating system support
Upgrade see SIMATIC NET Software
• As of Edition 2006 to 6GK1716-0HB00-3AE0 CP 1623 6GK1162-3AA00
S7-REDCONNECT Edition 2008 or communications processor
HARDNET-IE S7-REDCONNECT PCI Express x1 card
V12 for connection to Industrial Ethernet
• From V6.0, V6.1, V6.2 or V6.3 to 6GK1716-0HB00-3AE1 (10/100/1 000 Mbit/s),
S7-REDCONNECT Edition 2008 or with 2-port switch (RJ45)
HARDNET-IE S7-REDCONNECT via HARDNET-IE S7 and
V12 S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
CP 1628 6GK1162-8AA00
communications processor
PCI Express x1 card
for connection to Industrial Ethernet
(10/100/1 000 Mbit/s),
with 2-port switch (RJ45) and
integrated security (firewall, VPN)
via HARDNET-IE S7 and
S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET for Industrial Ethernet
■ Overview ■ Application
With SOFTNET for Industrial Ethernet, PC/PG and workstations
can be connected to programmable controllers, such as
SOFTNET/ SOFTNET/ SIMATIC S7, over Industrial Ethernet.
HARDNET-IE S7 and HARDNET-IE S7 and
IE S7 OPC Redundancy IE S7 OPC Redundancy HMI The following user interfaces are available:
• PG/OP communication for SIMATIC S7
2
• Open communication (SEND/RECEIVE) for communication
with SIMATIC S5 and S7
• S7 communication
SOFTNET is available for the following interfaces:
• Layer 2 Ethernet card (PCI/PCIe), e.g. CP 1612 A2
Industrial • integrated Industrial Ethernet interface
Ethernet • Modem/ISDN (Remote Access Service RAS)
■ Function
S7-1200 with S7-300 with
With SOFTNET, the complete protocol stack is processed
in the PC.
G_IK10_XX_10045
CP 1243-1 CP 343-1
This architecture means that in contrast to the CP 1613 A2/
CP 1623/CP 1628 communications processors, the perfor-
S7-400 with mance of the SOFTNET packages is dependent on the configu-
CP 443-1 ration or capacity utilization of the PC used.
System configuration SOFTNET for Industrial Ethernet The IT functionality is established in connection with the inter-
faces and the PC's Windows software.
ISO TCP/ PN MRP OPC PG/OP S7/S5 IT User interfaces
UDP
G_IK10_XX_10185
OPC interface
The OPC server included in the respective software package
can be used as the standard programming interface for the
• Software for coupling programming devices/workstations S7 communication and open communication protocols in
to automation systems order to connect automation technology applications to OPC-
• Communication services: compatible Windows applications such as Office, HMI systems,
- PG/OP communication etc.
- S7 communication Software for PG/OP communication
- Open communication (SEND/RECEIVE)
• Can be used with This software makes it possible to program the S7 controllers via
- Layer 2 Ethernet card (PCI/PCIe), e.g. CP 1612 A2 Industrial Ethernet in conjunction with the STEP 7 engineering
- Integrated Industrial Ethernet interface software.
- Modem/ISDN (Remote Access Service RAS) Software for S7 communication
• Complete protocol stack as a software package
SIMATIC S7 system components communicate with each other
• Increased availability thanks to additional option packages using S7 communication functions.
such as OPC Server Redundancy
The S7 communication can be based optionally on the
ISO protocol or the TCP/IP protocol.
■ Benefits
S7 communication offers the following services:
• Administrative services
• S7 connection management services
• Variable services
• Maximum transparency due to integrated communication with
SIMATIC via Industrial Ethernet and OPC as the standard • VFD (Virtual Field Device) services
interface • Trace and mini database
• Low-cost solution for industrial use in PCs that require smaller
quantity structures
• Simple and low-cost commissioning thanks to uniform
procedure and configuration functionality with NCM PC and
STEP 7
• Increased availability of the plant information by means of
redundant SIMATIC NET OPC server
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET for Industrial Ethernet
Industrial
G_IK10_XX_50194
Ethernet
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET for Industrial Ethernet
2
PG/OP communication, and electronic manual on CD-ROM,
NCM PC / STEP 7 Professional V12, license key on USB flash drive,
runtime software, software and Class A
electronic manual on CD-ROM,
license key on a USB stick, SOFTNET-IE PG V12
Class A For 32/64-bit:
SOFTNET-IE S7 V12 Windows 7 Professional/Ultimate;
for 64-bit:
For 32/64-bit Windows 2008 Server R2;
Windows 7 Professional/Ultimate; for 32/64-bit Windows 8 Pro;
for 64-bit: for Windows Server 2012:
Windows 2008 Server R2; German/English
for 32/64-bit Windows 8 Pro; • Single License for one installation 6GK1704-1PW12-0AA0
for Windows Server 2012
German/English Software update 6GK1704-1PW00-3AL0
Up to 64 connections For 1 year with automatic extension;
• Single License for one installation 6GK1704-1CW12-0AA0 requirement:
Current software version
Software Update Service 6GK1704-1CW00-3AL0
Upgrade
For 1 year with automatic extension; • From Edition 2006 to 6GK1704-1PW00-3AE0
requirement: Edition 2008 or V12
current software version • From V6.0, V6.1, V6.2 or V6.3 to 6GK1704-1PW00-3AE1
Upgrade Edition 2008 or V12
• From Edition 2006 to 6GK1704-1CW00-3AE0 IE S7 OPC Redundancy
Edition 2008 or V12
• From V6.0, V6.1, V6.2 or V6.3 to 6GK1704-1CW00-3AE1 Software for redundant
Edition 2008 or V12 OPC servers in the environment of
Industrial Ethernet software,
SOFTNET-IE S7 REDCONNECT S7 products, runtime software,
VM V12 software and electronic manual on
CD-ROM, license key on USB flash
Software for fail-safe S7 communi- drive, Class A
cation via redundant networks,
incl. S7 OPC server, IE S7 OPC Redundancy V12
runtime software, software and
electronic manual on CD-ROM, For 64-bit: Windows 2008 Server
license key on USB stick, Class A R2; German/English
for 32/64-bit: • Single License for one installation 6GK1706-1CW12-0AA0
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
for 32/64-bit Windows 8 Pro;
for Windows Server 2012
German/English;
• Single License for one installation 6GK1704-0HB12-0AA0
SOFTNET-IE S7 Lean Edition V12
For 32/64-bit
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
for 32/64-bit Windows 8 Pro;
for Windows Server 2012
German/English
Up to eight connections
• Single License for one installation 6GK1704-1LW12-0AA0
Software Update Service 6GK1704-1LW00-3AL0
For 1 year with automatic extension;
requirement:
Current software version
Upgrade
• From Edition 2006 to 6GK1704-1LW00-3AE0
Edition 2008 or V12
• From V6.0, V6.1, V6.2 or V6.3 to 6GK1704-1LW00-3AE1
Edition 2008 or V12
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET-IE RNA
■ Overview ■ Benefits
■ Application
The SOFTNET-IE RNA software package enables low-cost
• SOFTNET-IE RNA (Redundant Network Access is the software connection of non-PRP-enabled terminal equipment to parallel,
for connecting a PC to networks with PRP (Parallel Redun- separate networks in which high availability is demanded.
dancy Protocol in accordance with IEC62439-3) capability
• High level of plant availability thanks to duplicate transmission
of frames in two parallel, separate networks
■ Function
• Connection of PCs to parallel, separate networks (PRP)
• Reconfiguration times in a subnetwork do not affect the
propogation time because the frames are transmitted via two • Parallel data transfer over two parallel, separate networks
separate networks (bumpless redundancy) • Simple diagnostics via SNMP
• Integration in network management systems through support
Configuration
for SNMP
• Configuring tools are included in the scope of delivery of the A configuration tool is included in the scope of delivery of the
communication software in each case software package.
Industrial
Ethernet
(LAN A)
Industrial
Ethernet
(LAN B)
SIPROTEC SCALANCE
X204RNA
SIMATIC PC
S7-400 with
G_IK10_XX_10333
CP 443-1RNA
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET-IE RNA
2
integrated SNMP, runtime software, SNMP access, web diagnostics
software and electronic manual and PROFINET diagnostics,
on CD-ROM, for connecting non-PRP-enabled
license key on USB flash drive, terminal equipment
Class A to PRP networks;
incl. operating instructions,
For CP1612 A2 Industrial Ethernet network manual
SOFTNET-IE RNA V12 and configuration software
on CD-ROM;
For 32/64-bit with electrical and optical ports for
Windows 7 Professional/Ultimate; glass multimode fiber-optic cable
for 64-bit up to 5 km
Windows 2008 Server R2;
• SCALANCE X204RNA 6GK5204-0BA00-2KB2
for 32/64-bit Windows 8 Pro;
with four 100 Mbit/s RJ45 ports
for Windows Server 2012
German/English • SCALANCE X204RNA EEC 6GK5204-0BS00-3LA3
• Single License for one installation 6GK1711-1EW12-0AA0 with two 100 Mbit/s RJ45 ports
and two RJ45/SFP combo ports
Software Update Service 6GK1711-1EW00-3AL0
CP 443-1 RNA 67443-1RX00-0XE0
For 1 year with automatic extension; communications processor
requirement:
current software version for connecting the
SIMATIC S7-400/S7-400H CPU
Upgrade to Industrial Ethernet
• From V8.1 to V12 6GK1711-1EW00-3AE0
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET PN IO
■ Overview
OPC UA COM/DCOM
PROFINET
Communication
SOFTNET PN IO
PROFINET
Industrial Ethernet
IE/PB Link
PN IO
G_IK10_XX_10073
e. g. S7-300 with
CP 342-5 as Slave
ET 200S
ISO TCP/
UDP
PN MRP OPC PG/OP S7/S5 IT ■ Benefits
G_IK10_XX_10170
• Software with PROFINET IO Controller function for coupling • Cost-effective interfacing of field devices to Industrial Ethernet
PG/PC and IPC with PROFINET IO Devices with PROFINET
• Possible applications: • Simple porting of the application with OPC as a standard
- PC-based control systems interface
- HMI systems
- Test applications • High-performance IO data access through RT Base interface
for linking into C/C++ applications
• Communication services:
- PROFINET IO controller • Simple changeover from PROFIBUS modules
CP 5613 A2/CP 5614 A2 with DP-Base interface to
• Can be used with PROFINET through IO-Base interface
- Layer 2 Ethernet card (PCI/PCIe), e.g. CP 1612 A2
- Integral Industrial Ethernet interfaces of SIMATIC • Uniform procedure and configuration functions for NCM PC
programming devices/PCs and STEP 7
• Cost-effective solution for the low-end performance range
• OPC server for I/O connection over PROFINET included in
scope of delivery
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET PN IO
SOFTNET PN IO
■ Function Software for PROFINET IO
Controller with OPC server and
PROFINET communication NCM PC / STEP7 Professional V12,
PROFINET IO controller runtime software, software and
electronic manual on CD-ROM,
Connection of field devices to Industrial Ethernet with PROFINET license key on USB flash drive,
Class A
User interfaces SOFTNET-IE PN IO V12
OPC interface for 32/64-bit
Windows 7 Professional/Ultimate
The supplied OPC server can be used as a standard program- for Windows 2008 Server R2
ming interface for PROFINET IO controller to link automation ap- for 32/64 Bit Windows 8 Pro
plications to OPC-capable Windows applications (Office, HMI for Windows Server 2012
systems, etc.). German/English
• Single License for one installation 6GK1704-1HW12-0AA0
Programming interface via C Library;
Software Update Service 6GK1704-1HW00-3AL0
For applications that want to use the PROFINET IO controller for 1 year with automatic extension
functionality directly over C/C++, the IO-Base interface can be Requirement:
used. This interface is of a similar design to the DP Base inter- current software version
face of PROFIBUS modules CP 5613 A2 and CP 5614 A2. Upgrade
It is therefore possible to port existing PROFIBUS DP master • from Edition 2006 to 6GK1704-1HW00-3AE0
applications to PN IO-Controller applications. SOFTNET PN IO Edition 2008 or
V12
The released compilers can be found in the readme file
• from V6.0, V6.1, V6.2 or V6.3 to 6GK1704-1HW00-3AE1
of the SIMATIC NET CD products at SOFTNET PN IO Edition 2008 or
http://www.siemens.com/automation/csi/net. V12
SOFTNET PN IO and CP 1616 use compatible functions of the
IO-Base interface.
Mode of operation
With SOFTNET, the complete protocol stack is processed in the
PC. This architecture means that the performance depends on
the configuration of the PC used or the loading on the PC.
Configuration
Configuration is performed with STEP 7/NCM PC
PROFINET/Industrial Ethernet
Communication for PC-based systems
OPC server for Industrial Ethernet
■ Overview
PC/Windows PC
2 SIMATIC NET WinCC Microsoft Office OPC XML
OPC-Scout OPC-Client OPC-Client Webclient
OPC UA
COM/DCOM
Internet
Intranet
S7-1500 PC S7-1200
S7-1200 S7-400
S7-300
ET 200pro
SIMATIC S5
PC
G_IK10_XX 10103
SIMATIC S5
(SEND/RECEIVE only)
PROFIBUS
PROFINET/Industrial Ethernet
Communication for PC-based systems
OPC server for Industrial Ethernet
■ Application
The basic principle of OPC is that OPC client applications The OPC server offers, for example:
communicate with the OPC server over a standardized, open • Data Access interfaces 2.0, 2.05a and 3.0
and manufacturer-independent interface.
• Alarm and event interface 1.1
It is also possible to connect to OPC-capable Windows
applications (Microsoft Office or HMI systems) that are already
• OPC XML DA interface 1.0
• Integration of automation products of different manufacturers
2
available on the market.
The following communication possibilities are available for • Uniform, easy user interface for different components
Industrial Ethernet with OPC server: • Can be accessed from every computer in the LAN
• S7 communication • High-performance data access over the Custom Interface
• Open communication (SEND/RECEIVE) (C++, NET)
• PROFINET • Easy to use with the “Automation Interface“ (VB, NET) or the
supplied OCX Data Control or .NET Data Control
• SNMP (Simple Network Management Protocol)
• Grouping of variables (Items); which allows a large quantity of
data to be pre-processed in a short time.
• Optional redundancy expansion for S7 communication
■ Function
• Optimized data block access to S7-1500 • Interfaces
• Open standardization of the addressing using logical names - "Custom Interface“ for high-performance C++/NET
for objects from an automation component or an automation applications
system - "Automation Interface" for easily created Visual Basic
applications (or similar)
• Supports STEP 7 symbols - XML DA interface;
• Efficient data transfer from a process component to an Data access to S7 CPUs is therefore possible over the
application for further processing Internet.
• One client application can use several servers simultaneously - OCX Data Control or .NET Data Control for direct integration
in Windows applications that support COM/DCOM
• Simultaneous execution of more than one client is possible on
one OPC server
• Communication protocols can be used in parallel by means of
the multiplexer function
PN S7 FMS DP XY
G_IK10_XX_10106
Configuration
The communication parameters are configured entirely using
the tools of the installed SIMATIC NET software
PROFINET/Industrial Ethernet
Communication for PC-based systems
OPC server for Industrial Ethernet
PROFINET/Industrial Ethernet
Communication for PC-based systems
S7 OPC Redundancy for Industrial Ethernet
■ Overview ■ Design
OPC (Openness, Productivity & Collaboration) is a standard-
ized, open, and vendor-independent interface that is widely HMI
used in automation. OPC UA (Unified Architecture) is the result
of consistent further development of this standard, offering
additional functions such as security or redundancy. 2
S7 OPC Redundancy is a software product compliant with the
OPC UA standard that enables the redundant configuration of
OPC UA servers to SIMATIC S7. The availability of automation
data to operator control and monitoring systems is guaranteed Industrial Ethernet
thanks to the redundant use of OPC UA servers. This requires
neither additional cabling for synchronizing the redundant S7 OPC redundancy S7 OPC redundancy
OPC UA servers, nor additional programming overhead in OPC UA
the PC. The OPC UA servers are synchronized via high-perfor- synchronization
mance Industrial Ethernet network access points at 10/100
and 1 000 Mpbs. S7 OPC Redundancy represents an integrated
customer solution for all SIMATIC NET S7 SOFTNET and
HARDNET software products in the automation world.
■ Application
G_IK10_XX_10295
The redundant OPC UA server software enables redundant
configuration of SIMATIC NET OPC UA servers. Failure of one
OPC UA server, as a result of power outage or system failure, for
example, results in immediate use of the other OPC UA server,
and continuation of the existing OPC UA client connection.
This ensures increased availability of automation data to opera-
tor control and monitoring systems. Redundant use of OPC servers
PROFINET/Industrial Ethernet
Communication for PC-based systems
S7 OPC Redundancy for Industrial Ethernet
2 This means, for example, that the information synchronization of Industrial Ethernet software,
S7 products, runtime software,
between two SIMATIC NET S7 OPC servers via the S7 OPC software and electronic manual
Redundancy software package is guaranteed. This is handled on CD-ROM, license key on
transparently for the OPC Client application so that in the event USB flash drive, Class A
of a fault, the redundant OPC server takes over the tasks from S7 OPC Redundancy V12 for
the failed OPC server system. Industrial Ethernet
Data exchange between the OPC clients and the OPC servers for 64-bit: Windows 2008 Server R2;
takes place via the standardized OPC UA communication. German/English
Communication with the SIMATIC S7 controller takes place using • Single License for one installation 6GK1706-1CW12-0AA0
the S7 protocol. This is ensured by the software products
SIMATIC NET SOFTNET or HARDNET-S7 for Industrial Ethernet
that are necessary as the basis for SIMATIC NET IE S7 OPC
Redundancy.
The S7 OPC Redundancy software package supports:
• High availability;
Failure of one OPC UA server results in immediate use of the
other OPC UA server, and continuation of the existing OPC UA
client connection. The basis for this is the OPC UA synchroni-
zation that ensures synchronization of the necessary client
information.
• Load compensation;
Even distribution of OPC clients among the available OPC
servers
Configuration
A configuration tool is included in the scope of delivery of the
software package.
PROFINET/Industrial Ethernet
Communication for PC-based systems
SNMP OPC server
■ Overview ■ Application
The SNMP OPC server makes data available for the administra-
tion of TCP/IP networks for any OPC client systems.
SNMP (Simple Network Management Protocol) is a protocol that
2
Pumpstation Network
has been specifically designed for administration of TCP/IP
networks. The individual nodes in the network (network compo-
nents or data terminals) are equipped with a so-called SNMP
agent that provides information in structured form.
Pump Main
1GBit OPC (Openness, Productivity & Collaboration) provides a
standardized, open, multi-vendor interface for automation
engineering.
The SNMP OPC server supports access to device information
Pump Substation 1 over the OPC interface. This means that network visualization,
S_IK10_XX_00004
system diagnostics and plant status monitoring can be imple-
mented in any OPC client systems (with OPC clients such as
WinCC, WinCC flexible, PCS 7). In addition to simple device
Pump Old diagnostics, detailed information such as redundant network
structures or network load distribution can be displayed. This
increases the operational safety and improves the availability of
the plant.
• Status monitoring of SNMP-capable devices in any OPC client
The device information can be visualized according to individual
systems; e.g. SIMATIC WinCC/PCS 7
requirements and can be adapted to the special requirements of
• Easy access to SNMP-capable devices over the OPC the respective customer installation. The information that is
interface made available can also be integrated into the signaling system
• Devices without SNMP agents can be monitored using the and alarm log of an HMI/SCADA system for example.
ping mechanism Using the SNMP information, it is possible to expand an existing
• Configuration with STEP 7 (up to STEP 7 V5.5) or NCM PC HMI/SCADA system as far as a customer-specific network
• Ready-to-use SNMP diagnostics profiles for Siemens devices, management station.
e.g. SCALANCE X/W The SNMP OPC server can be operated over the following
• Generation of any SNMP diagnostics profiles by means of the interfaces:
integral MIB compiler • CP 1613 A2 (PCI)
• Easy setup of the monitored devices with the help of an • CP 1623 (PCIe)
Autodiscovery function
• CP 1628 (PCIe)
■ Benefits • Integrated Industrial Ethernet interface or CP 1612 A2
PROFINET/Industrial Ethernet
Communication for PC-based systems
SNMP OPC server
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTNET-S7/Linux
SOFTNET-S7/Linux functions
■ Overview
SIMATIC S7 system components communicate with each
• Software for connecting SIMATIC S7
other using S7 communication functions. The programming
• Provision of S7 communication via SAPI-S7 interface interface SAPI-S7 (Simple Application Programmer Interface) is
• Support of ISO and TCP/IP (RFC 1006) protocol available for Linux operating systems as well as for the Windows
2
operating systems.
• Available on Linux operating systems
• Simultaneous operation of several cards S7 communication offers the following services:
• Administrative services
• Variable services
sGSGotp • BSEND/BRECV
PC/PG
s G
pzvVvzp
zvm{ul{G with SOFTNET for Linux
z^Vs
sTiz
{jwVpw
pzv
nprXWXWW[X
zpth{pjGz^
S7-200
with CP 243-1
G_IK10_XX_10127
G_IK10_XX_10127
SOFTNET-S7/Linux system configuration
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTBUS for Linux
■ Overview
• Integrated communication
• Cross-computer communication
• Uniform interface
jG jG
jRR lywG
qh}h x GtUUU
m
zvm{i|z zvm{i|z
hkhw{ly hkhw{ly
zvm{i|z
zvm{i|z hwylk zvm{i|z
zvm{ul{Gz^
zlukGVGyljlp}l h
pzv l
ymjXWW] {jwVpw
zpth{pjGz^
nprXWXWW[`
ZG G
zpth{pjGz\
■ Benefits ■ Application
The process landscape in industrial companies is frequently a
product of historical developments. Thus there are many iso-
lated solutions that function optimally within their own terms of
reference but operate in a vacuum.
• Communication across the system with standardized
interface. Integrating these requires a smooth, loss-free and integrated
communication system. Only this guarantees that the right infor-
• Incorporation of ERP and DB systems. mation arrives at the right place and at the right time.
• Interfacing of SIMATIC control systems
SOFTBUS together with SOFTNET-S7 consists of matched mod-
• Fast and automatic data flow ules that are available on the commonly used system platforms
and thus ensure smooth communication between the system
platforms.
PROFINET/Industrial Ethernet
Communication for PC-based systems
SOFTBUS for Linux
PROFINET/Industrial Ethernet
Communication for PC-based systems
Software
Note:
The Windows XP software version is still available for older CPs;
see the Industry Mall: www.siemens.com/industrymall
PROFINET/Industrial Ethernet
Communication for PC-based systems
Software
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
■ Overview
The SIMATIC Basic Panel, Comfort Panel and Mobile Panel offer OPC communication
HMI functionality for the control systems:
OPC Data Access is an open standard for exchanging both local
• SIMATIC S7 and remote variables between various applications via Industrial
2 • Non-Siemens controllers:
- Allen Bradley
Ethernet.
- Mitsubishi
- Modicon HTTP communication for variable exchange between
- Omron SIMATIC HMI systems
For more detailed information, refer to the WinCC (TIA Portal) Communication based on HTTP message frames enables
user manual, the "Windows-based systems communication" variables to be exchanged between SIMATIC HMI systems.
manual, or the WinCC (TIA Portal) online help.
OPC communication and HTTP communication are offered for all
Panels with an integrated Ethernet interface. Both OPC and
HTTP communication can be used in parallel with the process
links to SIMATIC S7 or non-Siemens PLCs.
1) For the sake of simplicity, SIMATIC Panel is always used in the text
below. This is not restrictive, as the information is valid for all systems
referred to above. If there are constraints, direct reference is made to
them in the text.
Note:
Interface options for HMI devices: See the individual device
descriptions.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
SIMATIC S7
■ Overview
The following types of interface are differentiated in respect PPI interface
of the link between the SIMATIC Panels and SIMATIC S7
controllers: The PPI interface is a point-to-point connection between a
SIMATIC Panel (PPI master) or alternatively a PG (PPI master)
2
• PROFINET interface: and an S7-200 (PPI slave).
Coupling of SIMATIC Panel to SIMATIC S7 controllers via
Industrial Ethernet TCP/IP using the integrated PROFINET MPI/PROFIBUS interface or PROFINET interface
interface of the CPU or, alternatively, a PROFINET interface The corresponding multipoint-enabled communication inter-
module. faces of SIMATIC Panels and SIMATIC S7 are used.
• MPI/PROFIBUS interface: The following are possible:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via • Interface between one or more SIMATIC Panels (MPI master)
MPI/PROFIBUS using the integrated MPI/PROFIBUS interface and one or more S7-1200/S7-1500/S7-300/S7-400s or WinAC
of the CPU or the integrated PPI interface of the CPU in the (MPI master) (possible network topology: MPI/PROFIBUS or
case of S7-200 or, alternatively, a PROFIBUS interface module Industrial Ethernet, TCP/IP)
in the case of S7-1200, S7-1500, S7-300 and S7-400.
• Interface between one or a number of SIMATIC Panels (MPI
• PPI interface: master) and one or a number of S7-200s (MPI slave)1)
Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network (possible network topology: PPI, MPI/PROFIBUS)
using the integrated PPI interface of the CPU
Unlike PPI connections, MPI connections are static connections
The maximum possible number of S7 connections of one CPU is that are set up during booting and then monitored.
determined by its performance capacity (see Catalog ST 70);
from the point of view of SIMATIC Panel, the following restrictions The original format of a master/master link has been joined by a
apply: master/slave link, which has enabled integration of the S7-200
• Basic Panel, Comfort Panel 4", (except CPU 212).1)
Mobile Panel 177: max. 4 connections In principle this type of information exchange between SIMATIC
• Comfort Panel 7" - 22": max. 8 connections Panels and SIMATIC S7 is independent of the network used, PPI,
• Mobile Panel 277: max. 6 connections MPI/PROFIBUS or Industrial Ethernet: SIMATIC Panels are S7
clients and SIMATIC S7 CPUs are S7 servers.
• PC with WinCC Runtime Advanced: max. 8 connections
1)
With regard to restricted baud transmission rates for S7-200,
see Catalog ST 70.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
SIMATIC S7
■ Overview (continued)
Controller SIMATIC HMI
Target hardware (PROTOCOL) Basic Panel Comfort Panel Mobile Panel 177 DP 1) Mobile Panel 277 1) WinCC Runtime
(physics) Mobile Panel 177 PN 1) MP 177 Advanced
MP 277
2 SIMATIC S7-1200 2)
MP 377
1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout
2) Controllers can be combined as desired
3) Basic Panel PN and Mobile Panel 177 PN only
4) Basic Panel PN DP only or Mobile Panel 177 PN DP only
5) Connection via integrated MPI/PROFIBUS interface; in the case of a standard PC, a communications processor (CP) is to be used (e.g. CP 5611 A2)
Note:
Detailed information regarding cable layout can be found in the
online help for WinCC.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
SIMATIC WinCC (TIA Portal) Runtime
■ Overview
SIMATIC WinCC Runtime Advanced
visualization software
• PC-based HMI solution for single-user systems directly at the
2
machine
• Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
• Basic package expandable by means of option packages
• Can be integrated into automation solutions based on TCP/IP
networks
• Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication
SIMATIC WinCC Runtime Professional
visualization software
• PC-based operator control and monitoring system for visual-
ization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-
user station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
• Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
• Basic package expandable by means of option packages
• Also included are APIs for the Runtime to utilize the open
programming interfaces
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
■ Overview
Communication – SIMATIC WinCC Runtime Advanced
WinCC Advanced is an open visualization system and offers the
option of connecting the most diverse control systems.
2 Number of connectable controllers
WinCC Advanced permits the parallel coupling of up to
8 controllers.
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC Ad-
vanced. Generally it is also possible to connect third-party con-
trollers via OPC (OLE for Process Control).
Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Advanced supports the standards:
• OPC Data Access 2.05a
• OPC UA Data Access 1.01
• OPC XML Data Access 1.00 (client via DCOM/XML gateway)
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
■ Overview (continued)
Coupling overview for WinCC Runtime Advanced
Protocol Description PC interface
SIMATIC HMI
Ethernet TCP/IP
(HTTP communication)
HTTP communication for data exchange between SIMATIC HMI (client + server) 1) CP 1612 A2 2
SIMATIC S7
Ethernet TCP/IP Channel for communication via Ethernet TCP/IP with max. 8 x SIMATIC S7 controllers CP 1612 A2
(S7 communication) S7-1200, S7-1500 CP 1613 A2
S7-300, S7-400, CP 1623
S7-200 with CP 243-1
SINUMERIK 2)
Ethernet TCP/IP Channel for communication via Ethernet TCP/IP CP 1612 A2
(S7 communication) with SINUMERIK 840D sl CP 1613 A2
CP 1623
Third-party controllers (from WinCC V11.0) 3)
Allen Bradley Ethernet IP Channel for communication with max. 4 x Allen Bradley controllers CP 1612 A2
via Ethernet TCP/IP with Allen Bradley Ethernet IP protocol
The controllers ControlLogix / CompactLogix, SLC500 / MicroLogix and PLC5
are supported
Allen Bradley DF1 Channel for communication with Allen Bradley controllers via DF1 protocol COM1/COM2
The controllers SLC500 / MicroLogix and PLC5 are supported 3)
Mitsubishi MC TCP/IP Channel for communication with max. 4 x Mitsubishi controllers via Ethernet TCP/IP CP 1612 A2
with Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD controller series are supported
Mitsubishi FX Channel for communication with Mitsubishi controllers via FX protocol COM1/COM2
The FX1N, FX2N controllers are supported
Modbus TCP/IP Channel for communication with max. 4 x Modicon controllers CP 1612 A2
via Ethernet TCP/IP using the Modbus TCP/IP protocol
The Quantum, Momentum, Premium, TSX Micro, Compact and M340 controllers
are supported
Modbus RTU Channel for communication with Modicon controllers via the Modbus RTU protocol COM1/COM2
The Quantum, Momentum, and Compact controllers are supported
Omron Link / Multi Link Channel for communication with Omron controllers via the Link/Multi protocol COM1/COM2
The CP1x, CJ1x, CJ2H, CS1x, and CP2MC controllers are supported
Cross-manufacturer
OPC client 1) 4) for Channel for OPC communication, CP 1612 A2
OPC DA, OPC UA DA, XML DA WinCC can acquire data from OPC server applications
OPC server for OPC DA Server applications for OPC communication; CP 1612 A2
WinCC provides process data to PC clients
1) HTTP and OPC communication can be used in combination with the other couplings; regarding SIMATIC Panels
that support HTTP or OPC communication, see the overview under "System interfaces (WinCC V11)".
2)
"SINUMERIK Operate WinCC RT Advanced" license required; for further information, see NC 60 Catalog.
3)
For detailed information regarding supported controllers, see "System interfaces (WinCC V11)"
4)
Application note:
Parallel use of the OPC client channel allows, for example, connection to an SNMP OPC Server for visualization of the data present there.
The SNMP OPC Server enables monitoring of any network components (e.g. switches) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications systems/SNMP OPC Server.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
■ Overview (continued)
Communication – SIMATIC WinCC Runtime Professional Connection to third-party controllers
WinCC Professional is an open process visualization system and The following "Coupling overview" table lists third-party protocols
offers the option of connecting the most diverse control systems. and controllers which are directly supported by WinCC Profes-
2
sional. Generally it is also possible to connect third-party control-
Released communication software lers via OPC (OLE for Process Control).
Only communication software with the listed (or higher) product Current notes and information about OPC servers from many
versions should be used. Corresponding SIMATIC NET up- different suppliers can be found at:
grades are available for the upgrading of older versions. http://www.opcfoundation.org/
Number of connectable controllers WinCC Professional supports the standards:
With CP 1613/CP 1623, a maximum of 64 S7 controllers can • OPC Data Access 2.05a
be connected via Industrial Ethernet; with CP 5612/CP 5622 a
maximum of 8, and with CP 5613 A3 a maximum of 44 S7 • OPC Data Access 3.00
controllers can be connected via PROFIBUS. With approx. 10 or • OPC UA Data Access 1.01
more controllers, the use of Industrial Ethernet is recommended. • OPC XML Data Access 1.00
Client-server communication • OPC HDA 1.20
Communication between the clients and the server is • OPC A&E 1.10
implemented using the TCP/IP protocol. The construction of a
separate PC-LAN is recommended. For small projects with
correspondingly small message frame advent, a SIMATIC NET
Industrial Ethernet can be used for both process communication
(WinCC/server PLC) and for PC-PC communication
(WinCC/client WinCC/server)
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
■ Overview (continued)
Communications examples
Industrial Ethernet 2
SIMATIC S7-400
WinCC
Runtime
Advanced
PROFIBUS
SIMATIC S7-300
SIMATIC S7-1200
nz{_WWW[]`
WinCC Runtime Advanced single-user system
Industrial Ethernet
WinCC RT
Professional
Server
PROFIBUS
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
■ Overview (continued)
OPC Client
2 WinCC RT
Professional
Industrial Ethernet
OPC Server
WinCC RT
Advanced
PROFIBUS
nz{_WWW[^W
SIMATIC S7-300
SIMATIC S7-1200
OPC coupling
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ Overview ■ Application
SIMATIC WinCC flexible Runtime is the high-performance
visualization software for simple visualization tasks at machine
level. It can be used as a single-user solution for all automation
applications in factory automation, process automation and
building services automation. 2
SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
• SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PC 477
- Panel PC 577
- Panel PC 670/677
- Panel PC 870/877
• SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
• SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
PC-based visualization software for single-user systems directly
at the machine. • Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
• Runs under Windows XP Professional and Windows 7 1600 x 1200
Professional, Ultimate, Enterprise - Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
• Current version: SIMATIC WinCC flexible 2008 SP3 Runtime 1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
SIMATIC WinCC flexible Runtime is configured with the 1980 x 1080
SIMATIC WinCC flexible Advanced configuration software.
■ Design
■ Benefits SIMATIC WinCC flexible Runtime is available as a software
• Optimum price/performance ratio thanks to individually package with 128, 512, 2048 or 4096 PowerTags. The term
scalable system functionality PowerTags is used exclusively to identify process variables and
range pointers that have a process link to the controller.
• Functions for all visualization tasks: Variables without process link, constant limit values of variables,
Operator functions, graphical and trend displays, signaling and messages (up to 4000 bit-triggered messages) are also
system, log system, archiving (option), recipe management available for additional system performance.
(option), Audit Trail (option), process fault diagnostics (option)
• Flexible runtime functionality thanks to Visual Basic scripts The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and it
• Innovative service concepts with remote operation, can be expanded to suit requirements and costs by using
diagnostics and administration via intranet and Internet as optional packages.
well as e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on SIMATIC WinCC flexible Runtime is configured with the
TCP/IP networks at the machine level (option) SIMATIC WinCC flexible Advanced configuration software.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ Function
Visualization via Windows-compliant operator interface Open communication between
HMI systems and with higher-level systems 1)
made up of parameterizable screen objects and image blocks
created on a project-specific basis: • OPC server
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ Integration
SIMATIC WinCC flexible Runtime supports linking to: Application note
Protocol PC interfaces In parallel with each and every PLC link, WinCC flexible Runtime
supports the use of the OPC Client channel; this enables,
2
SIMATIC S7 via Ethernet (TCP/IP)
for example, connection to an SNMP OPC Server for the pur-
S7-200 with CP 243-1 CP 1612 1) pose of visualizing the data stored there. The SNMP OPC Server
CP 1613 A2 provides a means of monitoring network components of any type
S7-300 CPUs with integral Ethernet
interface (e.g. switches) which support the SNMP protocol. For further
S7-300 with CP 343-1
information, see Catalog IK PI.
S7-400 CPUs with integral Ethernet Note:
interface
For further information, see "HMI devices/System interfaces"
S7-400 with CP 443-1
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via integrated interface
WinAC Basis (V2.0 and higher) Internal system interface
WinAC RTX
SIMOTION 2)
SINUMERIK 3)
Third-party controllers
Allen Bradley (DF1/DH485) COM1/COM2
Allen Bradley (Ethernet) CP 1612 1)
GE Fanuc (SNP/SNPX) COM1/COM2
LG GLOFA GM COM1/COM2
Mitsubishi (FX/MP4) COM1/COM2
Modicon (Modbus) COM1/COM2
Modicon (Modbus TCP/IP) CP 1612 1)
OMRON (Link/Multilink) COM1/COM2
OPC 4) 6)
Data Access V2.05a (client + server) CP 1612 1)
Data Access XML V1.00 (client)
HTTP communication for data CP 1612 1)
exchange between SIMATIC HMI
(client + server) 5) 6)
1) For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet
interface
2) For further information, see Catalog PM 10
3) "SINUMERIK HMI copy license OA" option required;
for further information, see Catalog NC 60
4) OPC Client is included in scope of delivery,
the "WinCC flexible/OPC Server for WinCC flexible Runtime" license
is required for the OPC Server option
5) "WinCC flexible/Sm@rtAccess for WinCC flexible Runtime" license required
6) OPC and HTTP communication are additive, i.e. can be used in
conjunction with the PLC links listed above
7) Via PC cable with integrated level converter RS 232/TTY;
Article number: 6ES5734-1BD20
8) For information about SIMATIC Panels that support OPC/http communi-
cation, see the overview under "System interfaces".
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ Integration (continued)
Higher level visualization system
2
OPC Client
Industrial Ethernet
On-site visualization
OPC Server OPC Server
OPC Client
PROFIBUS 3rd party
SIMATIC S7-300 SIMATIC S7-400 OPC Server
Non-Siemens
PLCs
G_ST80_XX_00077
SIMATIC WinCC flexible Runtime application example
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ Technical specifications
Type SIMATIC WinCC flexible Runtime Type SIMATIC WinCC flexible Runtime
The specifications The specifications
are maximum values are maximum values
Displays
• Fields per screen
500
400
Password protection
• User rights 32
2
• Variables per screen 400 • Number of user groups 50
• Static text 30 000 Visual Basic scripts 200
• Graphics objects 2 000
• Complex objects per display 40 Online languages, max. 16
(e.g. bars) Communication
• Trends 800
SIMATIC S7 MPI interface/
• Graphics lists 1) 500 PROFIBUS DP interface
• Text lists 1) 500 • Number of connectable stations, Depending on the scope of the
• Number of entries in symbol tables 3 500 max. configuration (communication)
Variables 4 096 3) from the point of view of
WinCC flexible Runtime, as many as
Messages bit-triggered / analog 4 000 / 500 8 connections are possible
• Message text 80 SIMATIC S7 PPI interface
(number of characters)
• Number of connectable stations, 1 from viewpoint
• Number of process values 8 max. of WinCC flexible Runtime
per message
• Size of message buffer 1 024 SIMATIC S5
PROFIBUS DP interface
• Pending message events 500
• Number of connectable stations, 1 from viewpoint
Archives 4) 100 max. of WinCC flexible Runtime
• Archivable data Process data,
Multi-protocol operation Yes, OPC Client or SIMATIC HMI
messages
HTTP protocol are additive,
• Max. number of entries per archive 500,000 i.e. can be used in conjunction with
(incl. all archive segments) other PLC links
• Archive types Short-term archive, sequence archive
(max. 400 per archive)
• Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base), 1)
Together only 500 text and graphics lists
interface to MS SQL database 2)
Dependent on memory medium used
Recipes4) 1 000 3)
Dependent on number of licensed PowerTags
• Elements per recipe 2 000 3) 4)
Option for SIMATIC WinCC flexible Runtime. For further information,
• Data records per recipe 5 000 2) refer to "WinCC flexible options".
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC flexible
SIMATIC WinCC flexible RT
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible
Note:
Do you need a specific modification or option for the products
described here? You will find information about the Open
Platform Program for the creation of user-specific functions and
controls for WinCC flexible under "Customized Products".
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Overview
Current versions:
SIMATIC WinCC V7.3
2
Executable with
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows 8.1 (32 / 64 bit) Professional, Enterprise
• Windows 2008 Server SP2 (32 bit) Standard
• Windows 2008 Server R2 SP1(64 bit) Standard
• Windows Server 2012 R2 (64 bit) Standard
includes the Microsoft SQL Server 2008 R2 SP2 (32 bit)
SIMATIC WinCC V7.2
Executable with:
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows XP Professional SP3
• Windows Server 2003 SP2, Standard
• Windows Server 2008 SP2 (32 bit) Standard
• PC-based operator control and monitoring system for visual- • Windows Server 2008 R2 SP1 (64 bit) Standard
izing and operating processes, production flows, machines contains the Microsoft SQL Server 2008 R2 SP1 (32 bit)
and plants in all sectors – from the simple single-user station SIMATIC WinCC V7.0 SP3
through to distributed multi-user systems with redundant
servers and cross-location solutions with Web clients. Executable with:
WinCC is the information hub for corporation-wide vertical • Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
integration.
• Windows XP Professional SP3
• The basic system configuration (WinCC basic software)
includes industry-standard functions for signaling and • Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
acknowledging events, archiving of messages and measured Standard
values, logging of all process and configuration data, user • Windows Server 2008 SP2 (32 bit) Standard
administration and visualization. • Windows Server 2008 R2 SP1 (64 bit) Standard
• The WinCC basic software forms the core of a wide range includes the Microsoft SQL Server 2005 SP4
of different applications. Based on the open programming • Use in virtual environments – for additional information, see
interfaces, a wide range of WinCC options (from Siemens http://support.automation.siemens.com/WW/view/en/49370459
Industry Automation) and WinCC add-ons have been
developed (by Siemens-internal and external partners).
• WinCC can be operated with every PC that meets the given
HW requirements. The SIMATIC IPC product range is
available in particular for the industrial use of WinCC systems.
SIMATIC IPCs impress with their powerful PC technology, are
designed for round-the-clock operation, and can be operated
in both office areas and harsh industrial environments.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
New in V7.2
■ Benefits • Expansion into Graphic Designer
• All-purpose - Know-how protection by means of password protection for
- Solutions for all sectors PDL images and image blocks
- Multilingual for worldwide usage
- Can be integrated into all automation solutions • Unicode support
1)
V6: 128, 256, 1024, 8192, 65536 PowerTags
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Function ■ Integration
The powerful configuration functions of SIMATIC WinCC contrib- Integration in company-wide solutions
ute to a reduced engineering and training overhead and lead to (IT and business integration)
a more flexible use of personnel and greater operational reliabil-
ity. Whoever is familiar with Microsoft Windows can also operate WinCC is strictly based on Microsoft technology, which provides
the WinCC Explorer, the central switching point of WinCC. the greatest possible compatibility and integration ability.
ActiveX and .net 1) controls support technology-specific and 2
In combination with other SIMATIC components, the system is industry-specific expansions. Cross-manufacturer communica-
also equipped with auxiliary functions such as process diagnos- tion is also a simple exercise. The reason: WinCC can be used
tics and maintenance. All SIMATIC engineering tools work to- as an OPC client and server, and in addition to access to current
gether in the configuration of the functions. process values, it also supports standards such as OPC HDA
SIMATIC WinCC offers a complete basic functionality for pro- (Historical Data Access), OPC Alarm & Events, and OPC XML
cess visualization and operation. To this end WinCC has a num- Data Access.
ber of editors and interfaces that can be used to individually Just as important: Visual Basic for Applications (VBA) for user-
configure this functionality according to the respective applica- specific expansions of the WinCC Graphics Designer and Visual
tion. Expansions of a WinCC station for control tasks are also Basic Scripting (VBS) as an easy-to-learn, open runtime lan-
possible with minimal engineering effort. guage. If desired, professional application developers can also
use ANSI-C. And access to the API programming interfaces is
WinCC editors Task or configurable runtime really simple with the Open Development Kit ODK.
functionality
WinCC Explorer Central project management for the WinCC integrates a powerful and scalable historian function
quick access to all project data and based on Microsoft SQL Server 2005 into the basic system.
central settings As a result, users have every possibility: from high-performance
WinCC Graphics Designer Graphics system for user-defined archiving of current process data, to long-term archiving with
visualization and operation via pixel- high data compression, through to a central information hub in
graphic objects the form of a company-wide process historian. With the help
WinCC Alarm Logging Signaling system for detecting and of the Central Archive Server option, this can be set up within
archiving events with display and the framework of a WinCC solution. Versatile clients and tools
control options according to DIN for evaluation, the open interfaces, and special options
19235; freely selectable message (Connectivity Pack, Connectivity Station, IndustrialDataBridge)
classes, message display and provide the basis for effective IT and business integration.
logging
WinCC Tag Logging Process archiving for the acquisition, If external networks are accessed, suitable protective measures
compression and storage of mea- (incl. IT security measures, such as network segmentation)
sured values, e.g., presentation in should be taken in order to ensure safe operation of the system.
trend and table format as well as
further processing You can find more information on the topic of Industrial Security
WinCC Report Designer Reporting and logging system for
on the Internet at:
time and event-controlled documen- http://www.siemens.com/industrialsecurity
tation of messages, operator inputs
1)
and current process data in the Only supported in WinCC V7.0 or higher
form of user reports or project docu-
mentation in an arbitrary layout Integration in automation solutions
WinCC User Administrator Tool for user-friendly administration of
users and authorizations WinCC is an open process visualization system and provides
the option to connect the most diverse control systems.
WinCC Global Script Processing functions with limitless
functionality by means of the use of Approved communication software
VBScript and ANSI-C
Only communication software with the listed product versions
Interfaces (or higher) should be used. Corresponding SIMATIC NET up-
grades are available for upgrading older versions.
Task or configurable runtime
functionality Number of connectable controls
Communication channels For communication with subordinate For the number of controls connectable via Industrial Ethernet
controls (SIMATIC protocols, CP 1613, the following applies to a message frame length of
PROFIBUS DP, PROFIBUS FMS, DDE
and OPC server included in the
512 bytes:
scope of delivery)
Type of connection Number of nodes
Standard interfaces For the open integration of other
Windows applications via WinCC, SIMATIC S5 Ethernet Layer 4 Up to 60
WinCC-OLE-DB, ActiveX, OLE, DDE, + TCP/IP
OPC, etc.) SIMATIC S7 Protocol Suite Up to 64
Programming ports For the individual access to data and SIMATIC 505 Ethernet Layer 4 up to 60
functions of WinCC and for the + TCP/IP
integration in user programs with
VBA, VB Script, C-API (ODK),
C-Script (ANSI-C) Via PROFIBUS, a maximum of 8 controls can be connected with
CP 5611, and a maximum of 44 controls with CP 5613. With
approx. 10 or more controls, the usage of Industrial Ethernet is
recommended.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Integration (continued)
Mixed operation with different controls Connection overview
With their multi-protocol stack, the CP 1613 and CP 5613 com- Protocol Description
munication processors allow parallel operation of two protocols,
SIMATIC S7
2
such as for the mixed operation of different controls, via a bus
cable. WinCC supports the operation of two similar interface SIMATIC S7 Protocol Suite Channel DLL for S7 functions via MPI,
boards only in connection with the channels SIMATIC S5 Ether- PROFIBUS or Ethernet Layer 4 +
TCP/IP
net Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite (2 x
CP 1613, 2 x CP 5613) as well as PROFIBUS DP (4 x CP 5613; SIMATIC S5
each CP 5613 max. 122 slaves). In addition to communication SIMATIC S5 Ethernet Layer 4 Channel DLL for S5 Layer 4
over industrial Ethernet CP 1613 or PROFIBUS CP 5613, one CP communication + TCP/IP
5611 can be used in each case for communication with SIMATIC SIMATIC S5 Programmer Port AS511 Channel DLL and driver for serial
S7 via MPI. communication with S5 using AS511
protocol to programmers port
Client-server communication
SIMATIC S5 Serial 3964R Channel DLL and driver for serial
Communication between the clients and the server is via TCP/IP communication with S5 using RK512
protocol. Setting up a separate PC LAN is recommended. For protocol
small projects with a correspondingly low incidence of message SIMATIC S5 PROFIBUS-FDL Channel DLL for S5-FDL
frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server PLC) SIMATIC 505
and PC-PC communication (WinCC/client WinCC/server). SIMATIC 505 Serial Channel DLL and driver for serial
communication with 505 using NITP/
Channel DLL PROFIBUS DP TBP protocol to SIMATIC 535/545/
555/565/575
In accordance with the PROFIBUS standard, DP/slaves are al-
ways permanently assigned to a DP master; i.e. a second SIMATIC 505 Ethernet Layer 4 Channel DLL for 505 Layer 4
WinCC station (DP/master) cannot access the same controls communication
(DP/slave). This means that redundant operation of two WinCC SIMATIC 505 TCP/IP Channel DLL for 505 TCP/IP
stations is not possible using the PROFIBUS DP connection. communication
Connection to controls from other manufacturers: SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher)
SIMATIC S7-1200, S7-1500 Channel DLL for S7-1200 and
OPC (OLE for Process Control) is recommended for the connec- Channel 1) S7-1500 communication
tion of controls from other manufacturers.
Controllers from other manufacturers (from WinCC V7.0 SP3)
Current notes and information about OPC servers from various Allen Bradley Channel DLL and drivers for commu-
suppliers can be found at: Ethernet IP nication with Allen Bradley controllers
http://www.opcfoundation.org via Ethernet TCP/IP using Ethernet IP
protocol
WinCC supports the standards:
Modbus TCP/IP Channel DLL and drivers for commu-
• OPC Data Access 2.05a nication with Modicon controllers via
• OPC Data Access 3.00 Ethernet TCP/IP using Modbus TCP/
IP protocol
• OPC XML Data Access 1.00
Mitsubishi MC TCP/IP Channel DLL and drivers for commu-
(Connectivity Pack/Connectivity Station) nication with Mitsubishi controllers via
• OPC HDA 1.20 (Connectivity Pack/Connectivity Station) Ethernet TCP/IP using Mitsubishi MC
TCP/IP protocol
• OPC A&E 1.10 (Connectivity Pack/Connectivity Station)
Cross-manufacturer
• OPC UA Client Data Access
OPC Client 2) 3) for DA, XML DA Channel DLL for OPC communica-
• OPC UA Server Data Access, HDA tion, WinCC can acquire data from
(Connectivity Pack / Connectivity Station) OPC server applications.
OPC Server for DA, XML DA, A&E, Server applications for OPC commu-
HDA nication; WinCC provides process
data to OPC clients
OPC UA server for DA, HDA Server applications for OPC UA
communication
PROFIBUS FMS Channel DLL for PROFIBUS FMS
PROFIBUS DP Channel DLL for PROFIBUS DP
SIMOTION Channel DLL for SIMOTION
1)
WinCC version V7.2 or higher supports communication
with S7-1200 / S7-1500 CPU.
Restrictions:
No symbolic address, type safe structure support (absolute address only)
No CPU alarming support
2)
Application note:
Parallel usage of the OPC client channel allows, for example, connection
to an SNMP-OPC server for visualization of the data contained there.
The SNMP OPC server enables monitoring of any network components
(such as switches) that support the SNMP protocol. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.
3)
WinCC V7.0 SP3 and later supports OPC UA (United Architecture)
Client for DA.
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Integration (continued)
Communications components for PG/PC for SIMATIC (for WinCC V7.2)
Industrial Ethernet SIMATIC S5 SIMATIC S5 SIMATIC S7 SIMATIC 505 SIMATIC 505 Article No.
Ethernet Layer 4 TCP/IP Protocol Suite Ethernet Layer 4 TCP/IP 1)
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4 • • Included in the basic
2
Channel DLL for S5 Layer 4 package
communication + TCP/IP
SIMATIC S7 Protocol Suite • Included in the basic
Channel DLL for S7 functions package
SIMATIC 505 Ethernet Layer 4 • Included in the basic
Channel DLL for 505 Layer 4 package
communication
SIMATIC 505 TCP/IP 1) • Included in the basic
Channel DLL for 505 TCP/IP package
communication
Communication components for extension of the OS/OP
CP 1612 A2 • • • 6GK1161-2AA01
PCI card for connecting a PG/PC to
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communication
software must be ordered separately)
SOFTNET-IE S7 • •
communication software for
S7 functions (max. 64 connections)
• Version 12 2) 6GK1704-1CW12-0AA0
for 32/64-bit Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
for 32/64-bit Windows 8 Pro;
for Windows Server 2012
German/English
• Edition 2008 SP2 (V7.1) 2) 6GK1704-1CW71-3AA0
for Windows XP/2003 Server/(32-bit)
2008 Server
SOFTNET-IE S7 Lean • •
communication software for
S7 functions (max. 8 connections)
• Version 12 2) 6GK1704-1LW12-0AA0
for 32/64-bit Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
for 32/64-bit Windows 8 Pro;
German/English
• Edition 2008 SP2 (V7.1) 2) 3) 6GK1704-1LW71-3AA0
for Windows XP/2003 Server /
(32-bit) 2008 Server
CP 1613 A2 • • • • • 6GK1161-3AA01
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(S7-1613 communication software
required)
CP 1623 • • • • • 6GK1162-3AA00
PCI Express X1 card (32-bit)
for connecting a PG/PC to Industrial
Ethernet (S7-1613 communication
software required)
HARDNET-IE S7 • • • •
communication software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
• Version 12 2) 6GK1716-1CB08-2AA0
for 32/64-bit Windows Server 2012,
Windows 8 Pro, Windows 7
Professional / Ultimate;
for 64-bit: Windows 2008 Server R2;
German/English
• Edition 2008 SP2 (V7.1) 2) 6GK1716-1CB71-3AA0
for Windows XP/2003 Server /
(32-bit) 2008 Server
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Integration (continued)
Communication examples
2
SIMATIC NET Industrial Ethernet (S7 functions)
- CP 1613 A2
Standard PC with WinCC 6GK1161-3AA01
e.g. RC 64 k or RT 64 k - CP 1623
6GK1162-3AA00
- S7-1613
(communication software)
6GK1716-1CB80-3AA0
Industrial Ethernet
- CP 443-1 (S7, S/R) ISO + TCP - CP 343-1 (S7, S/R) ISO + TCP
6GK7443-1EX30-0XE0 6GK7343-1EX30-0XE0
- CP 443-1 Advanced - CP 343-1 Advanced
(S7, S/R, HTTP) (S7, S/R, HTTP)
6GK7443-1GX30-0XE0 6GK7343-1GX31-0XE0
G_ST80_XX_00011
- NCM S7 manual Industrial Ethernet - NCM S7 manual Industrial Ethernet
(SIMATIC NET CD or (SIMATIC NET CD or
Internet download) Internet download)
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Integration (continued)
Industrial Ethernet
- OPC Server functionality
- OPC Server On-site visualization (included in WinCC
functionality OPC Server OPC Server
basic package)
(OPC Server - TCP-IP Interface board
option for required
WinCC flexible
required)
OPC Client
- integrated - OPC Client
OPC Server
PROFIBUS PROFIBUS functionality (included
interface in WinCC basic
SIMATIC SIMATIC
package)
S7-300 S7-400
- OPC Server required
third-party for interfacing with
PLCs
G_ST80_XX_00015
third-party PLCs
OPC link
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
■ Technical specifications
Type SIMATIC WinCC V7.2 and V7.0 SP3 SIMATIC WinCC V6.2 SP3
Operating system • Windows 7 (32 bit / 64 bit) Ultimate, Professional and • Windows XP Professional SP3,
Enterprise • Windows 2000 Professional SP4,
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
1)
According to licensing provisions, 1 upgrade package must be ordered
for each WinCC station
2)
The Software Update Service is valid for 1 year.
The contract is automatically extended by 1 more year unless canceled
3 months prior to expiration. According to licensing provisions,
1 Software Update Service must be ordered for each WinCC station.
3)
Requires the current software version
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
2
• 10 000 archives 6AV6371-1DQ16-2CX0
• 128 to 256 PowerTags 6AV6371-1BD06-2AX0 • 30 000 archives 6AV6371-1DQ16-2EX0
• 128 to 1 024 PowerTags 6AV6371-1BE06-2AX0 • 80 000 archives 6AV6371-1DQ16-2GX0
• 128 to 8 192 PowerTags 6AV6371-1BK06-2AX0 • 120 000 archives 6AV6371-1DQ16-2JX0
• 128 to 65 536 PowerTags 6AV6371-1BF06-2AX0
• 256 to 1 024 PowerTags 6AV6371-1BG06-2AX0 SIMATIC WinCC V6.2 Archive Powerpacks
• 256 to 8 192 PowerTags 6AV6371-1BL06-2AX0 For upgrading archiving from
• 256 to 65 536 PowerTags 6AV6371-1BH06-2AX0 • 1 500 to 5 000 archive tags 6AV6371-1DQ16-2AB0
• 1 024 to 8 192 PowerTags 6AV6371-1BM06-2AX0 • 5 000 to 10 000 archive tags 6AV6371-1DQ16-2BC0
• 1 024 to 65 536 PowerTags 6AV6371-1BJ06-2AX0 • 10 000 to 30 000 archive tags 6AV6371-1DQ16-2CE0
• 8 192 to 65 536 PowerTags 6AV6371-1BN06-2AX0 • 30 000 to 80 000 archive tags 6AV6371-1DQ16-2EG0
Complete packages • 80 000 to 120 000 archive tags 6AV6371-1DQ16-2GJ0
• 128 to 256 PowerTags 6AV6371-1BD16-2AX0 SIMATIC WinCC V6.2 upgrade 1)
• 128 to 1 024 PowerTags 6AV6371-1BE16-2AX0 For upgrading the RT version
• 128 to 8 192 PowerTags 6AV6371-1BK16-2AX0 • from V5.x to V6.2 SP3 6AV6381-1AA06-2AX4
• 128 to 65 536 PowerTags 6AV6371-1BF16-2AX0 • from V6.x to V6.2 SP3 6AV6381-1AA06-2AX3
• 256 to 1 024 PowerTags 6AV6371-1BG16-2AX0 • from V5.x ASIA to V6.2 SP3 ASIA 6AV6381-1AA06-2AV4
• 256 to 8 192 PowerTags 6AV6371-1BL16-2AX0 • from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AA06-2AV3
• 256 to 65 536 PowerTags 6AV6371-1BH16-2AX0
• 1 024 to 8 192 PowerTags 6AV6371-1BM16-2AX0 For upgrading the RC version
• 1 024 to 65 536 PowerTags 6AV6371-1BJ16-2AX0 • from V5.x to V6.2 SP3 6AV6381-1AB06-2AX4
• 8 192 to 65 536 PowerTags 6AV6371-1BN16-2AX0 • from V6.x to V6.2 SP3 6AV6381-1AB06-2AX3
• from V5.x ASIA to V6.2 SP3 ASIA 6AV6381-1AB06-2AV4
• from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AB06-2AV3
1)
According to licensing provisions,
1 upgrade package must be ordered for each WinCC station.
■ More information
WinCC language versions Separate configurators are available for PC hardware:
SIMATIC WinCC is also offered in simplified Chinese, traditional • SIMATIC IPC547C
Chinese, Korean and Japanese especially for Asian markets. • SIMATIC IPC647C
These WinCC versions are intended for machine manufacturers, • SIMATIC IPC847C
plant constructors and exporters who supply the regions of
China, Taiwan, Korea and Japan. • SIMATIC IPC427C, SIMATIC IPC427D
WinCC ASIA includes all familiar WinCC functions and offers • SIMATIC IPC627C
in addition the configuration user interface in the respective • SIMATIC Box PC 827C
national language and English. The online help is available in • SIMATIC IPC477C, SIMATIC IPC477D
simplified Chinese, traditional Chinese, Korean, Japanese and
English. A Chinese, Korean, Japanese or multilingual Windows • SIMATIC HMI IPC577C
operating system is required for operation. • SIMATIC HMI IPC677C
WinCC ASIA is delivered on a separate DVD which contains all
of the above mentioned language versions. The corresponding
documentation can be obtained from the national subsidiaries in
China, Korea, Taiwan and Japan.
The runtime licenses are language-neutral. The English handling
program (Automation License Manager – ALM) is executable
under the Chinese, Korean and Japanese Windows versions.
In order to use the Asian languages in WinCC, an Asia hardware
dongle is required.
Additional information is available on the Internet at:
http://www.siemens.com/wincc
PROFINET/Industrial Ethernet
Accessories
C-PLUG
■ Overview ■ Design
The C-PLUG has degree of protection IP20. The degree of
protection of IP65 components is ensured by the design of the
target device. The power supply is also provided by the end
device.
2 The C-PLUG is inserted in the associated slot of the SIMATIC
NET component. The configuration data are automatically saved
to the C-PLUG during device start-up and reconfiguring.
If a device needs to be replaced, the C-PLUG is simply removed
from the failed component and plugged into the replacement
device. The replacement device installed in the network or auto-
mation system now starts up automatically with the same device
configuration as the failed device.
To prevent unintentional removal or falling out, the C-PLUG slot
is usually located on the rear of the terminal devices.
■ Benefits
■ Application
The C-PLUG is used when it is necessary for network compo-
nents or communication modules to be replaced quickly and
easily in the event of a fault without the need for reconfiguring the
replacement part and without the need for special training. Plugging the C-PLUG into the SCALANCE XM408-8C switch
PROFINET/Industrial Ethernet
Accessories
C-PLUG
Incorrect C-PLUG handling, such as inserting a C-PLUG that Degree of protection IP20
contains the configuration of another device group or general
malfunctions of the C-PLUG are signaled over the diagnostic
mechanisms for the respective data terminal (LEDs, PROFINET, ■ Ordering data Article No.
SNMP, Web-based Management, etc.).
C-PLUG 6GK1900-0AB00
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Overview
Introduction For this purpose, the SICLOCK product family offers a compre-
hensive range of optimally matched components for setting up
highly reliable time synchronization systems.
GPS satellite
SICLOCK
GPS1000
SIMATIC HMI
SICLOCK
Twin wire TC400
max. 1 000 m
ETH1
●
● Ethernet Switch SP01_00017
●
SCALANCE X
Industrial Ethernet ETH4
Outdoor installation
up to 4 independent Ethernet networks
SICLOCK TC400 central plant clock with SICLOCK GPS1000 wireless receiver
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Application
Application examples
System with GPS reception
GPS satellite
SICLOCK
GPS1000
SIMATIC HMI
SICLOCK
Twin wire TC400
max. 1 000 m
ETH1
●
● Ethernet Switch SP01_00017
●
SCALANCE X
Industrial Ethernet ETH4
Outdoor installation
up to 4 independent Ethernet networks
SICLOCK TC400 central plant clock with SICLOCK GPS1000 wireless receiver
The SICLOCK GPS1000 wireless receiver (Article No. The SICLOCK TC400 central plant clock shown in the example
2XV9450-1AR84) is used in this example. The wireless receiver features four 10/100 Mbit Ethernet interfaces for supplying up to
is mounted outdoors with "visual contact" to the navigation satel- four independent IP networks. The SICLOCK TC100 central
lites for optimum reception quality. plant clock with one Ethernet interface has been designed for
smaller, cost-sensitive plants.
The line current method (TTY - 20 mA) used in the SICLOCK sys-
tem permits distances of up to one kilometer between the wire- The central plant clocks do not have Ethernet switching
less receiver and the central plant clock and also supplies the functionality for safety reasons. SIMATIC NET SCALANCE X
receiver with power, which eliminates the need for any additional switches are recommended for this purpose, see
power supply components. This makes it possible to install the http://support.automation.siemens.com/WW/view/en/18689247/
central plant clock at a central location, even in plants spread 133200.
over a very large area.
up to 1500 km
SICLOCK
DCFRS
ETH1
●
● SP01_00018
●
Industrial Ethernet ETH4
Outdoor installation/
Indoor installation up to 4 independent Ethernet networks
SICLOCK TC400 central plant clock with SICLOCK DCFRS wireless receiver
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Application (continued)
As an alternative to receiving satellite signals, the DCF77 time The advantages over satellite reception are lower costs and the
signal transmitter can be used as primary time source. The option of mounting the receiver inside a building. The last advan-
transmitter is located near Frankfurt am Main and transmits long- tage is especially useful if outdoor installation is not advisable,
wave signals at a frequency of 77.5 kHz. Under normal condi- e.g. due to vandalism.
2 tions, reception is possible up to a distance of about 1 500 km
from the transmitter. Redundant modes
The SICLOCK DCFRS wireless receiver with TTY output Due to the importance of having a reliable time supply in many
(Article No. 2XV9450-1AR16) is used in this application. demanding applications, the SICLOCK system offers optional
Here too, a separate power supply is not required if a redundant modes to further increase plant reliability. The redun-
SICLOCK TC100 or SICLOCK TC400 central plant clock is dancy can be on the reception side, the network side, or even
used. be combined with a redundant central plant clock for highly sen-
sitive applications.
Reception-side redundancy
GPS satellite
SICLOCK
GPS1000
SICLOCK
Twin wire TC400
max. 1000 m
ETH1
●
●
●
Industrial Ethernet ETH4
Outdoor installation
up to 4 independent Ethernet networks
SICLOCK
DCFRS
DCF77
longwave time signal
Mainflingen near
Twin wire
Frankfurt/Main
max. 1000 m
SP01_00021
Outdoor installation/
Indoor installation
SICLOCK TC400 central plant clock with SICLOCK GPS1000 and SICLOCK DCFRS wireless receivers
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Application (continued)
Highly redundant system
SICLOCK SICLOCK
TC400 TC400 NTP server
Twin wire NTP server Slave
max. 1 000 m Master
ETH1
SIMATIC S7 Controller
SICLOCK TC400 central plant clocks with SICLOCK GPS1000 wireless receiver
This application can satisfy the highest redundancy require- If SICLOCK GPS1000 wireless receivers are used, they should
ments. The system uses two SICLOCK TC400 central plant be mounted as far away from each other as possible so that the
clocks, each with separate SICLOCK GPS1000 wireless receiver with the better reception conditions can be used and,
receivers for example, to avoid damage to both receivers in the event of a
lightning strike. Instead of using two GPS wireless receivers, one
One central plant clock is parameterized as the NTP server SICLOCK DCFRS wireless receiver can of course be used.
master, the other as the NTP server slave. The NTP server slave
takes over if the NTP master or the connected wireless receiver
fails.
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Application (continued)
Synchronization of IT networks
IT network with a central plant clock
GPS satellite
SICLOCK
GPS1000
SICLOCK
TC100
Twin wire
max. 1 000 m Industrial Ethernet Switch
e. g. SCALANCE XR-500
Industrial Ethernet
SP01_00025
Outdoor installation
Windows PCs
+ SICLOCK reception
service
SICLOCK TC100 central plant clock with SICLOCK GPS1000 wireless receiver: Synchronization of IT systems (with failure protection)
PROFINET/Industrial Ethernet
Accessories
Time synchronization
■ Application (continued)
Simple solution without failure protection for the direct supply of clock time to IT systems
GPS satellite
SICLOCK
GPS1000
SP01_00024
SICLOCK
GPS1000 PS
Twin wire
max. 1 000 m RS 232
Windows PCs
+ SICLOCK reception service
Outdoor installation
SICLOCK GPS1000 PS pulse converter with SICLOCK GPS1000 wireless receiver, synchronization of IT systems (without failure protection)
■ More information
For more information, go to
• www.siemens.com/siclock
• E-mail: siclock@siemens.com
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > Central plant clocks
2
these then generate signals which
are used to synchronize the con-
nected I/O devices.
• SICLOCK TC400 central plant 2XV9450-2AR01
clock, single device
• SICLOCK TC100 central plant 2XV9450-2AR22
clock, single device
The central plant clocks evaluate the clock time data that was
transmitted from the wireless receiver and generate diverse
output signals in order to synchronize the connected I/O
devices.
If the wireless receiver fails or signal transmission is interrupted,
the central plant clocks switch over to their internal high-preci-
sion quartz system and thus ensure reliable tracking of the clock
time. When the input signal is available again, the central plant
clock adjusts any time differences that may have occurred
without time jumps by means of "microsteps".
Inputs and outputs
The high-precision SICLOCK TC100 and SICLOCK TC400
central plant clocks have one (SICLOCK TC100) or two
(SICLOCK TC400) inputs for connection to wireless receivers.
The central plant clocks have one (SICLOCK TC100) or four
(SICLOCK TC400) independent 10/100 Mbit Ethernet inter-
faces.
The network stations are synchronized using the proven SNTP
standard and by means of the SIMATIC procedure.
The SICLOCK central plant clocks have two relay outputs for
signaling alarms or warnings.
Alternatively and/or in addition, two point-to-point connections
TTY (20 mA current interface) or one RS 422 (5 V level) connec-
tion can be set up for the SICLOCK TC400 central plant clock.
Operation
Parameterization of the interfaces, setting of the signal types,
redundancy modes, and read-out of the status messages stored
in the device are conveniently implemented via the integrated
web interface.
LEDs and a display indicate operating states and show any error
messages, which can also be read out via the web interface.
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > GPS receivers
Wireless receivers
SICLOCK GPS1000 package 2XV9450-1AR82
GPS radio clock for the time
synchronization of PCs as well as
programmable controllers via 2
RS 232 interface;
in industrial environments with
high levels of interference;
with distances up to 1000 m
between the antenna and the
device,
package comprises
• GPS1000 antenna head
with antenna frame
• GPS1000 power supply
• Distribution socket
• 5 m RS232 connecting cable
• DCF77 receiving service
for Windows
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > DCF77 receivers
Wireless receivers
SICLOCK DCFRS 2XV9450-1AR16
DCF radio clock for the time
2 synchronization of PCs and pro-
grammable controllers
• Active DCF77 antenna
with TTY output
(20 mA line current)
spare part
SICLOCK DCFRS 2XV9450-1AR06
DCF radio clock for the time
synchronization of individual PCs
over short distances,
package comprises
• Active DCF77 antenna with
RS 232 interface and mounting
bracket
• 20 m connecting cable, mounted
SICLOCK DCFRS wireless receiver (without antenna base) SICLOCK DCFRS 2XV9450-1AR14
DCF radio clock for the time
SICLOCK DCFRS wireless receivers receive signals from the synchronization of individual PCs
DCF77 time signal transmitter. The DCF77 transmitter is located over short distances,
package comprises
in Mainflingen near Frankfurt am Main and transmits long-wave
signals at a frequency of 77.5 kHz. Under good reception • Active DCF77 antenna with
RS 232 interface and mounting
conditions, signals can be received within a radius of up to bracket
1 500 km of the transmitter location.
• 20 m connecting cable, mounted
Unlike devices that receive signals from satellites, the • DCF77 receiving service for
SICLOCK DCFRS can also be used inside buildings. Windows
SICLOCK DCF77 wireless receivers output the demodulated SICLOCK DCFRS 2XV9450-1AR21
DCF77 time signal.
DCF radio clock for the time
SICLOCK DCF77 wireless receivers are available in two synchronization of PCs and pro-
versions: grammable controllers
package comprises
• SICLOCK DCFRS with TTY interface (20 mA current interface) • Active DCF77 antenna with
for direct connection to central plant clocks TTY output (20 mA line current)
• SICLOCK DCFRS with RS 232 signal level for connection and antenna frame
to PCs • TTY/RS 232 converter
• Plug-in power supply
Note:
• Two distribution sockets
We recommend the software DCF77 receiving service • 1 m connecting cable mounted,
(Article No. 2XV9450-1AR28) if the RS 232 version is used, see extendable to 1000 m
"Accessories". Parameter assignment is not necessary for both • DCF77 receiving service
receiver versions. for Windows
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > Pulse converters
■ Overview
The pulse converter is available in three versions:
• SICLOCK PCON Inputs Outputs
• SICLOCK EOPC
2
LWL LWL
• SICLOCK GPS1000 PS
TTY
RS 485 RS 485
5 ... 35 V 245 V
35 ... 70 V 220 V
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > Pulse converters
Pulse converters
SICLOCK PCON 2XV9450-1AR63-1SA3
Single-channel,
2 electrical-optical pulse converter
for industrial applications,
820 nm, 24 ... 230 V AC/DC,
with multimode fiber optic
connection
SICLOCK EOPC 2XV9450-1AR72
Electrical-optical pulse converter
for industrial applications
with 32 fiber-optic cable outlets
for transparent operation and
pulse mode, 24 ... 110 V DC
SICLOCK GPS1000 2XV9450-1AR85-0AA2
power supply 230 V
PROFINET/Industrial Ethernet
Accessories
SICLOCK Time synchronization > Accessories
Software Accessories
For less complex applications, the wireless receivers can even Software
be operated without central plant clocks. • Receiving service software 2XV9450-1AR28
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Automation systems
■ Overview
Automation systems are available in three different designs for • Modular systems of the S7-400 series with hardware controller
the SIMATIC PCS 7 process control system. The automation in the versions "Standard", "High availability" and "Safety-
performance can therefore be finely scaled within wide limits. related"
- AS 410 automation systems
The automation systems offered can be classified as follows: - Complementary S7-400 systems
• Embedded systems with software controller
- mEC automation system
- Microbox automation system
■ Application
Automation system AS AS AS AS AS AS AS AS AS AS AS AS
with APL 412H 414-3 414-3IE 414H 416-2 416-3 416-3IE 416H 417-4 417H RTX mEC
AS 410
Analog value measurements 10 50 100 100 200 400 400 400 500 600 300 300
Digital value measurements 20 160 250 250 450 800 800 800 1 000 1 000 600 600
PID controls 5 35 50 50 75 150 150 150 180 200 200 200
Motors 7 40 75 75 100 200 200 200 350 400 150 150
Valves 7 40 75 75 100 200 200 200 350 400 250 250
SFC 0 15 15 15 40 100 100 100 200 200 100 100
Steps 0 150 150 150 400 1 000 1 000 1 000 2 000 2 000 800 800
Dosing 0 3 3 3 15 25 25 25 50 50 50 50
Digital inputs DI 30 200 350 300 600 1 200 1 200 1 200 1 700 1 800 1 200 1 200
Digital outputs DO 10 60 100 110 200 400 400 400 550 650 400 400
Analog inputs AI 15 100 175 150 300 600 600 600 800 900 600 600
Analog outputs AO 5 30 75 50 100 200 200 200 250 350 200 200
Process objects (PO) 30 200 350 350 600 1 200 1 200 1 200 1 800 2 000 1 200 1 200
Typical mixed configuration limits for SIMATIC PCS 7 automation systems, based on the SIMATIC PCS 7 Advanced Process Library (APL)
Note:
The values quoted here are not AS-specific maximum values for
the particular item. Instead, they represent a typical distribution
of the available total capacity of the AS during mixed operation
of all the items of a contiguous block.
The number of process objects is not an absolute value, but
depends on the library used as well as on the number and type
of blocks used in the application.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Automation systems
2
ing and communication performance. The product range offered "Modular AS 410 systems".
differs with regard to the area of application as follows: • For information and ordering data for AS 412 to AS 417
• AS 410 automation systems automation systems (standard systems, high availability and
- Preferred systems for new plants with SIMATIC PCS 7 V8.0 safety-related systems), see "Complementary S7-400
- Suitable for SIMATIC PCS 7 as of V8.0+SP1, including systems" in the following.
hardware upgrade package (HUP CPU 410-5H) • For detailed information and ordering data for the SIMATIC
- Performance of the general purpose CPU scalable based on PCS 7 AS mEC RTX automation system, see the section
the number of process objects "Embedded systems", "mEC automation system" below.
AS type Features • For detailed information and ordering data for the SIMATIC
Standard systems, high availability and safety-related systems PCS 7 AS RTX automation system, see the section
"Embedded systems", "Microbox automation system" below.
AS 410S/H/F/FH CPU 410-5H Process Automation (1 x or 2 x)
Interfaces: 1 x PN/IE (2 ports), 1 x DP Online configurators
• Complementary S7-400 systems Selected SIMATIC S7-400 components are combined as
- Can be used in plants with SIMATIC PCS 7 V8.0, V7.1, "AS bundles" according to the task involved for the modular
or V7.0 SIMATIC PCS 7 automation systems. Configurators in the
- As an alternative to AS 410, primarily in systems with Industry Mall (www.siemens.com/industrymall) help you to
SIMATIC PCS 7 V7.0/V7.1 assemble the AS bundles:
- Scalable based on types of CPU differing in performance • Online configurators for AS 410 automation systems
AS type Features
- SIMATIC PCS 7 AS 410 Single Station configurator
- SIMATIC PCS 7 AS 410 Redundancy Station configurator
Standard systems
• Online configurators for complementary S7-400 systems
AS 414-3 Standard CPU, interfaces: 1 x MPI/DP, 1 x DP, - SIMATIC PCS 7 AS Single Station configurator
1 x DP module can be optionally inserted - SIMATIC PCS 7 AS Redundancy Station configurator
AS 414-3IE Standard CPU, interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP,
1 x DP module can be optionally inserted
AS 416-2 Standard CPU, interfaces: 1 x MPI/DP, 1 x DP
AS 416-3 Standard CPU, interfaces: 1 x MPI/DP, 1 x DP, 1 x DP
module can be optionally inserted
AS 416-3IE Standard CPU, interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP,
1 x DP module can be optionally inserted
AS 417-4 Standard CPU, interfaces: 1 x MPI/DP, 1 x DP, 2 x DP
module can be optionally inserted
High availability and safety-related systems
AS 412H/F/FH H-CPU (1 x or 2 x),
interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP, 1 x DP
AS 414H/F/FH H-CPU (1 x or 2 x),
interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP, 1 x DP
AS 416H/F/FH H-CPU (1 x or 2 x),
interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP, 1 x DP
AS 417H/F/FH H-CPU (1 x or 2 x),
interfaces: 1 x PN/IE (2 ports), 1 x MPI/DP, 1 x DP
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
AS 410 modular systems
■ Overview
With the rugged all-round system AS 410, the SIMATIC PCS 7 System expansion cards are available for
process control system for the first time offers an exclusive • 100 PO
automation system from the SIMATIC S7-400 series, which can
be used in all domains due to its versatility. For specific require- • 500 PO
2 ments, you can configure it as a:
• Standard AS 410S automation system
• 1 000 PO
• 1 600 PO
• Fault-tolerant AS 410H automation system • 2 000 PO (PO 2k+)
• Safety-related AS 410F/FH automation system The type reduction to a single CPU offers numerous advantages.
With its high-performance hardware and optimized V8.0 firm- It significantly simplifies selection and configuration of the
ware, the innovative CPU 410-5H Process Automation of the automation system as well as spare part inventory and plant
AS 410 covers the entire spectrum of conventional AS 412 to expansion.
AS 417 automation systems. Its automation performance can be Note:
flexibly scaled based on the number of SIMATIC PCS 7 process
objects (PO). The configuration of the CPU 410-5H Process Automation of the
AS 410 and the loading of the user blocks is only possible with
SIMATIC PCS 7 engineering software as of V8.0+SP1 (including
hardware upgrade package HUP CPU 410-5H) .
■ Design
Similar to all SIMATIC PCS 7 automation systems of the S7-400 The configuration of the AS bundles and their article numbers
series, AS 410 automation systems are available as "AS bun- can be defined by selecting pre-configured ordering units.
dles" as follows: System-specific ordering configurations are available in tabular
• Individual components bundled per system in one delivery form for this purpose in the sections "Standard automation
systems", "Fault-tolerant automation systems" and "Safety-
• Pre-assembled and tested complete systems (no extra related automation systems".
charge compared to delivery of individual components)
For interactive configuration of AS bundles, two online
With a SIMATIC PCS 7 Industry Library Runtime license and a configurators are also available in the Industry Mall
SIMATIC PCS 7 AS Runtime license, the AS bundles are (www.siemens.com/industrymall):
equipped for 100 process objects (PO). Building on this, the
number of process objects can be increased with cumulative • SIMATIC PCS 7 AS 410 Single Station configurator
AS Runtime licenses for 100, 1 000 or 10 000 POs. • SIMATIC PCS 7 AS 410 Redundancy Station configurator
■ Single power supply ■ Double power supply ■ Single power supply ■ Double power supply
■ Single plant bus communi- ■ Single plant bus communi- ■ Double plant bus ■ Double plant bus
cation cation communication communication
(Single Controller)
Single Station
■ Double power supply ■ Quadruple power supply ■ Double power supply ■ Quadruple power supply
■ Double plant bus communi- ■ Double plant bus communi- ■ Quadruple plant bus ■ Quadruple plant bus
cation cation communication communication
Redundancy Station
(Dual Controller)
G_PCS7_XX_00185
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
AS 410 modular systems
■ Design (continued)
A particular characteristic of the modular S7-400 systems is the CPU 410-5H Process Automation supports NTP as well as S7
flexible and scalable availability of various components. time synchronization.
For a SIMATIC PCS 7 AS Single Station of the AS 410 type, you Other features include:
2
have the option of specifically increasing the availability by • Integrated 48 MB load memory and 16 MB RAM each for
implementing a redundant configuration of the power supply or program and data
the Industrial Ethernet communications module, and combining
these measures. • Cycle time up to 10 ms/9 process tasks
• Total number of I/Os (on PROFIBUS DP and PROFINET IO)
Even the AS Redundancy Station of the AS 410 type with its approx. 7 500 (16 KB each for inputs and outputs)
redundant CPUs offers significantly higher availability. It oper-
ates according to the 1oo2 principle, in which a switch is made • Additional protection of the circuit board with coating
from the active subsystem to the standby system in the event of (conformal coating)
a fault. Starting from here, you can double the power supply or • High-precision time stamping
the Industrial Ethernet communications module for each sub- • Recessed RESET button
system, and combine these measures.
• Preset hardware parameters (PCS 7 skinning)
CPU 410-5H Process Automation
For detailed information about CPU 410-5H Process Automa-
tion, see "Technical specifications".
I/O connection via PROFIBUS DP
The distributed process I/O can be integrated into a
PROFIBUS DP segment either directly or via a lower-level field-
bus (PROFIBUS PA or FOUNDATION Fieldbus H1). For details
on this, see sections "PROFIBUS DP", "PROFIBUS PA" and
"FOUNDATION Fieldbus H1" in the "Communication" chapter.
PROFIBUS DP segments with distributed process I/O can be
operated on a PROFIBUS DP interface in the CPU and on
additive CP 443-5 Extended (conformal coating) PROFIBUS DP
interfaces. You can configure up to 4 individual or redundant
PROFIBUS DP CP 443-5 Extended PROFIBUS DP interfaces (conformal
PROFINET IO
(2-port switch)
coating) for an automation system using the configurators for
SIMATIC PCS 7 automation systems in the Industry Mall as
well as in the catalog sections "Standard automation systems",
"Fault-tolerant automation systems" and "Safety-related auto-
2 slots for the Service mation systems".
sync module (2 x RJ45)
G_PCS7_XX_00350
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
AS 410 modular systems
■ Technical specifications
CPU 410-5H Process Automation CPU 410-5H Process Automation
General information Communication
Firmware version V8.0 Number of S7 connections 120
2 Engineering with SIMATIC PCS 7 V8.0+SP1 +
HUP CPU 410-5H
Alarm_8P 10 000 (max. 80 000 messages)
Interfaces
Degree of protection IP20 • X1: PROFIBUS DP 1 x up to 12 Mbps, 9-pin Sub-D
Version Conformal coating socket
• X5: PROFINET IO with 2 ports 2 x 10/100 Mbps, RJ45
Power supply • X8: Service 2 x RJ45
Supply voltage 5 V DC from SV system • IF1: Sync module slot Sync module 1
(redundant systems)
Input current
• IF2: Sync module slot Sync module 2
• From backplane bus, 5 V DC max. 1.7 A (redundant systems)
• From interface 5 V DC, max. 90 mA
Electromagnetic compatibility
Power loss, typical 7.5 W (EMC)
Memory Emission of radio interference Limit class A, for use in industrial
RAM acc. to EN 55011 areas
• For program 16 MB Climatic conditions
• For data 16 MB Temperature
Load memory, integrated 48 MB • Operation 0 ... 60 °C
Buffering with battery Yes, all data Relative humidity
CPU performance • Operation 0 to 95%, without condensation
■ Accessories
Backup batteries
Lithium backup batteries of type AA with 2.3 Ah are used in the The following backup batteries are required depending on the
power supply modules of all SIMATIC PCS 7 automation systems configuration of the AS bundles:
of the S7-400 range (AS bundles). Since lithium batteries are • SIMATIC PCS 7 AS Single Station with
easily inflammable, more rigorous transport and storage regula- - 1 power supply module: 2 units
tions apply to them. - 2 redundant power supply modules: 4 units
To avoid subjecting the AS bundles to these more rigorous trans- • SIMATIC PCS 7 AS Redundancy Station with
port and storage regulations, the backup batteries must be - 2 power supply modules: 4 units
ordered and delivered separately (order no. 6ES7971-0BA00). - 2 x 2 redundant power supply modules: 8 units
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Standard automation systems
■ Overview
The AS 410S modular standard automation systems are suitable
for general use. These are always your first choice if high avail-
ability through redundancy and safety-related functions are not
relevant for the application.
In the range from 100 to approx. 2 600 PO, their performance 2
can be customized to meet the task at hand using expansion
cards (for more information, see the previous section of the
catalog "Modular S7-400 systems").
An AS 410S is also the base system for a fault-tolerant
(AS 410H) or a safety-related automation system (AS 410F,
AS 410FH). Your decision for the AS 410S is therefore not final,
you can remain flexible. If the task changes, the automation
system can be used differently at any time and the target system
can be expanded accordingly.
■ Design
Individual configuration of AS bundles
The equipment of the standard automation systems as well as AS Single Station
their article numbers can be individually compiled by selecting with PROFINET CPU
pre-configured ordering units.
Typical combinations can be selected from tables in the section
"Ordering data". The complete range is available to you via the
SIMATIC PCS 7 AS 410 Single Station online configurator in the
Industry Mall (www.siemens.com/industrymall). ET 200M ET 200M
I/O connection via PROFIBUS DP SCALANCE X
Several PROFIBUS DP segments with distributed process I/Os
can be operated on one standard automation system.
G_PCS7_XX_00323
A PROFIBUS DP interface is already integrated in the ET 200M
ET 200M
CPU 410-5H Process Automation. Using the configurator in
the Industry Mall or in the selection and ordering data, up to
four more PROFIBUS DP interfaces can be configured via
additional CP 443-5 PROFIBUS DP interfaces (conformal
coating).
Example for PROFINET IO communication with media redundancy
I/O connection via PROFINET IO
Standard automation systems AS 410S can only be connected Industrial Ethernet (IE) plant bus communication
to remote I/O stations, for example, ET 200M remote I/O stations If the PROFINET interface integrated in the CPU is not used for
via the PROFINET interface (2-port switch) integrated in PROFINET IO, it can also be used for the connection to the
CPU 410-5H Process Automation (see also chapter "Communi- Industrial Ethernet plant bus. Otherwise, the AS 410S standard
cations", section "PROFINET"). automation system can be connected to the Industrial Ethernet
The availability of the I/O devices can be increased by a ring plant bus via a CP 443-1 (conformal coating) communication
topology with media redundancy (MRP). If the transmission link module. The availability of the plant bus communication can be
in the ring is interrupted at a given location, for example, due to increased with a second communication module.
a break in the ring cable or the failure of a station, the redun-
dancy manager, e.g. the CPU, immediately activates the alterna- Redundant power supply
tive communication path. If you have two separate power supply networks for your plant,
you can increase the availability of the AS 410S standard auto-
mation systems by using two redundant power supplies.
Runtime licenses
With a SIMATIC PCS 7 Industry Library Runtime license and a
SIMATIC PCS 7 AS Runtime license, the AS bundle is equipped
for 100 process objects (PO). The number of process objects
can be extended by additional Runtime licenses for 100, 1 000
or 10 000 POs. The process objects of additional Runtime
licenses can be added to process objects which already exist.
The number and type (e.g. 100 or 1 000) of additional Runtime
licenses are irrelevant with regard to the implementable quantity
framework.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Standard automation systems
2
CPU 410-5H Process Automation 6ES7410-5HX08-0AB0
gram and data) with SIMATIC PCS 7
(conformal coating)
AS Runtime license for 100 PO and
32 MB RAM integrated
SIMATIC PCS 7 Industry Library
(16 MB each for program and data);
Runtime license
module occupies 2 slots
Type of delivery
CPU 410-5H Process Automation 6ES7654-5CJ00-0XF0
• Individual components, 5 100 PO Bundle
not pre-assembled CPU bundle, consisting of
• Pre-assembled and tested 6 CPU 410-5H Process Automation
and system expansion card
System expansion card for 100 PO
• System expansion card 100 PO J CPU 410-5H Process Automation 6ES7654-5CL00-0XF0
• System expansion card 500 PO L 500 PO Bundle
• System expansion card 1 000 PO N CPU bundle, consisting of
CPU 410-5H Process Automation
• System expansion card 1 600 PO P and system expansion card
• System expansion card PO 2k+ Q for 500 PO
( 2 000)
CPU 410-5H Process Automation 6ES7654-5CN00-0XF0
Additive Industrial Ethernet 1 000 PO Bundle
interfaces1) CPU bundle, consisting of
• Without CP 443-1 0 CPU 410-5H Process Automation
and system expansion card
• 1 x CP 443-1 (conformal coating) 3 for 1 000 PO
• 2 x CP 443-1 (conformal coating) 4
CPU 410-5H Process Automation 6ES7654-5CP00-0XF0
Racks 1 600 PO Bundle
• UR2 (9 slots), aluminum1) 3 CPU bundle, consisting of
CPU 410-5H Process Automation
• UR2 (9 slots), steel1) 4 and system expansion card
• UR1 (18 slots), aluminum 5 for 1 600 PO
• UR1 (18 slots), steel 6 CPU 410-5H Process Automation 6ES7654-5CQ00-0XF0
Power supply PO 2k+ Bundle
CPU bundle, consisting of
(without backup batteries)
CPU 410-5H Process Automation
• 1 x PS 407, 10 A B and system expansion card
for 120/230 V AC/DC for PO 2k+ ( 2 000)
• 1 x PS 407, 10 A C SIMATIC NET CP 443-1 6GK7443-1EX30-0XE1
for 120/230 V AC/DC, (conformal coating)
optional redundancy Communication module for
• 1 x PS 407, 20 A D connecting SIMATIC S7-400 to
for 120/230 V AC/DC Industrial Ethernet through TCP/IP,
• 2 x PS 407, 10 A E ISO, and UDP;
for 120/230 V AC/DC, redundant PROFINET IO controller, MRP;
integrated real-time switch ERTEC
• 1 x PS 405, 10 A for 24 V DC G with two ports;
• 1 x PS 405, 10 A for 24 V DC, H 2 x RJ45 interface;
optional redundancy S7 communication, open communi-
• 1 x PS 405, 20 A for 24 V DC J cation (SEND/RECEIVE) with
FETCH/WRITE, with or without
• 2 x PS 405, 10 A for 24 V DC, K RFC 1006, DHCP, SNMP V2,
redundant diagnostics, multicast, access
Additive PROFIBUS DP protection over IP access list,
interfaces1) initialization over LAN
10/100 Mbit/s;
• Without CP 443-5 Extended 0 with electronic manual on DVD
• 1 x CP 443-5 Extended 1
(conformal coating) SIMATIC NET CP 443-5 Extended 6GK7443-5DX05-0XE1
(conformal coating)
• 2 x CP 443-5 Extended 2 Communications processor for
(conformal coating) connection of SIMATIC S7-400 to
• 3 x CP 443-5 Extended 3 PROFIBUS as DP master or for S7
(conformal coating) communication, for increasing the
• 4 x CP 443-5 Extended 4 number of DP lines, for data set
(conformal coating) routing with SIMATIC PDM and for
10-ms time stamping, electronic
manual on CD;
module occupies 1 slot
1)
Up to 5 CPs (Industrial Ethernet/PROFIBUS) can be plugged
into the UR2 rack with a single power supply, or up to 3 with a redundant
power supply.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Standard automation systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Fault-tolerant automation systems
I/O connection via PROFIBUS DP
■ Overview
The distributed process I/O can be integrated into a
PROFIBUS DP segment either directly or via a lower-level field-
bus (PROFIBUS PA or FOUNDATION Fieldbus H1).
Several PROFIBUS DP segments with distributed process I/Os
2 can be operated on an AS 410H high availability automation
system. A PROFIBUS DP interface is integrated in each of the
two CPUs 410-5H Process Automation. Using the online config-
urator in the Industry Mall or in the selection and ordering data,
up to four more PROFIBUS DP interfaces can be configured for
each redundant subsystem with add-on CP 443-5
PROFIBUS DP interfaces (conformal coating).
With redundant PROFIBUS DP lines, the process I/Os can be
connected to an AS 410H as follows:
• ET 200M remote I/Os stations with two IM 153-2 High Feature
interface modules on a special bus module
• ET 200iSP remote I/Os stations with two IM 152-1 on a special
terminal module
• Field devices on the PROFIBUS PA over a PA link to two
Redundancy Station AS 410H redundant IM 153-2 High Feature interface modules
• Field devices on the FOUNDATION Fieldbus H1 via an FF link
Fault-tolerant automation systems are used to reduce the risk of with two redundant IM 153-2 FF interface modules
production failures. The higher investment costs for fault-tolerant
automation systems are frequently negligible compared to the • Non-redundant PROFIBUS DP devices, e.g. ET 200S or
costs resulting from production failures. The higher the costs of ET 200pro remote I/O stations per Y-Link
a production failure, the more worthwhile it is to use a fault- I/O connection via PROFINET IO
tolerant system.
High availability AS 410H automation systems can be con-
The SIMATIC PCS 7 fault-tolerant automation systems can be nected via PROFINET IO with remote I/O stations, for example,
used on their own in a plant configuration, or together with ET 200M remote I/O stations. Only the PROFINET interfaces
standard and safety-related automation systems. integrated in the CPUs can be used for this on the automation
system.
■ Design The maximum availability with minimum error reaction times is
The AS 410H, which consists of two redundant, galvanically achieved by the AS 410H when used in conjunction with system
isolated subsystems, can be mounted on a UR2-H compact rack redundancy of the I/O devices. System redundancy refers to a
with a split backplane bus or on two separate racks (UR1 or type of PROFINET IO communication in which each I/O device
UR2). The configuration in two racks has the advantage that the establishes a communication link to each of the two CPUs of an
redundant subsystems are spatially separated (for example, by AS 410H over the topological network. Then, the failure of a CPU
a fire-proof wall) and can be located far apart from each other. does not automatically lead to failure of the connected I/O
Depending on the sync modules used, distances from 10 m to devices.
10 km are possible between the two subsystems. As a result of
the electrical isolation, the system is also resistant to EMC
interference. AS redundancy
Individual configuration of AS bundles station with
PROFINET CPU
The equipment of the high availability automation systems as
well as their article numbers can be individually defined by se-
lecting pre-configured ordering units.
Typical combinations can be selected from tables in the section ET 200M ET 200M
"Ordering data". The complete range for selection is available via
SCALANCE X
the SIMATIC PCS 7 AS 410 Redundancy Station online configu-
rator in the Industry Mall (www.siemens.com/industrymall).
G_PCS7_XX_00322
Ordering information:
ET 200M ET 200M
• For an AS 410H redundant configuration based on two
AS Single Stations (AS 410S), you additionally require 4 sync
modules (up to 10 m or up to 10 km) and 2 fiber-optic sync
cables. The selection depends on the distance between the
two AS Single Stations.
• FO sync cables longer than 1 m must always be ordered PROFINET IO communication with system redundancy
separately (2 cables required in each case).
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Fault-tolerant automation systems
2
tion to the Industrial Ethernet plant bus. Otherwise, the two sub- gram and data) with SIMATIC PCS 7
systems of the AS 410H can be connected to the plant bus using AS Runtime license for 100 PO and
one CP 443-1 communication module (conformal coating) each. SIMATIC PCS 7 Industry Library
Runtime license
The plant bus can be implemented in the form of a ring structure,
Type of delivery
which can also be configured with redundant architecture if the
availability requirements are high. When there are two redundant • Individual components, 5
not pre-assembled
rings it makes sense to use two communications processors in
each case and to distribute their connections between the two • Pre-assembled and tested 6
rings (4-way connection). Double faults such as failure of the System expansion card
switch on ring 1 with simultaneous interruption of the bus cable • 2 x System expansion card J
on ring 2 can thus be tolerated. 100 POs
• 2 x System expansion card L
Runtime licenses 500 POs
With SIMATIC PCS 7 Industry Library Runtime and the • 2 x System expansion card N
SIMATIC PCS 7 AS Runtime license, the automation systems are 1 000 POs
equipped with 100 process objects (PO) on delivery. The num- • 2 x System expansion card P
1 600 POs
ber of process objects can be extended by additional Runtime
licenses for 100, 1 000 or 10 000 POs. The process objects of • 2 x System expansion card PO 2k+ Q
( 2 000)
additional Runtime licenses can be added to process objects
which already exist. The number and type (e.g. 100 or 1 000) of Sync modules and cables
additional Runtime licenses are irrelevant. • 2 x 2 sync modules for distances 3
up to 10 m and 2 x FO sync cable,
1m
• 2 x 2 sync modules for up to 10 km 4
and 2 x FO sync cable, 1 m, for
testing
Additive Industrial Ethernet
interfaces1)
• Without CP 443-1 0
• 2 x 1 CP 443-1 (conformal coating) 3
• 2 x 2 CP 443-1 (conformal coating) 4
Racks
• 1 x UR2-H (2 x 9 slots), aluminum1) 1
• 1 x UR2-H (2 x 9 slots), steel1) 2
• 2 x UR2 (9 slots), aluminum1) 3
• 2 x UR2 (9 slots), steel1) 4
Power supply
(without backup batteries)
• 2 x PS 407, 10 A B
for 120/230 V AC/DC
• 2 x PS 407, 10 A C
for 120/230 V AC/DC,
optional redundancy
• 2 x PS 407, 20 A D
for 120/230 V AC/DC
• 2 x 2 PS 407, 10 A E
for 120/230 V AC/DC, redundant
• 2 x PS 405, 10 A for 24 V DC G
• 2 x PS 405, 10 A for 24 V DC, H
optional redundancy
• 2 x PS 405, 20 A for 24 V DC J
• 2 x 2 PS 405, 10 A for 24 V DC, K
redundant
Additive PROFIBUS DP
interfaces1)
• Without CP 443-5 Extended 0
• 2 x 1 CP 443-5 Extended 1
(conformal coating)
• 2 x 2 CP 443-5 Extended 2
(conformal coating)
• 2 x 3 CP 443-5 Extended 3
(conformal coating)
• 2 x 4 CP 443-5 Extended 4
(conformal coating)
1)
In configurations with UR2/UR2-H racks, up to 5 CPs (Industrial Ethernet/
PROFIBUS) can be configured with a single power supply, or up to 3 CPs
for each subsystem with a redundant power supply.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Fault-tolerant automation systems
2
Communication module for
CPU 410-5H Process Automation 6ES7410-5HX08-0AB0 connecting SIMATIC S7-400 to
(conformal coating) Industrial Ethernet through TCP/IP,
32 MB RAM integrated (16 MB ISO and UDP;
each for program and data); PROFINET IO controller, MRP;
module occupies 2 slots integrated real-time switch ERTEC
CPU 410-5H Process Automation 6ES7654-5CJ00-0XF0 with 2 ports;
100 PO Bundle 2 x RJ45 interface;
CPU bundle, consisting of S7 communication, open communi-
CPU 410-5H Process Automation cation (SEND/RECEIVE) with
and system expansion card for FETCH/WRITE, with or without
100 PO RFC 1006, DHCP, SNMP V2,
diagnostics, multicast,
CPU 410-5H Process Automation 6ES7654-5CL00-0XF0 access protection over IP access
500 PO Bundle list, initialization over LAN
CPU bundle, consisting of 10/100 Mbit/s;
CPU 410-5H Process Automation with electronic manual on DVD
and system expansion card for
500 PO SIMATIC NET CP 443-5 Extended 6GK7443-5DX05-0XE1
(conformal coating)
CPU 410-5H Process Automation 6ES7654-5CN00-0XF0 Communication module for
1 000 PO Bundle connection of SIMATIC S7-400 to
CPU bundle, consisting of PROFIBUS as DP master or for
CPU 410-5H Process Automation S7 communication, for increasing
and system expansion card for the number of DP lines, for data set
1 000 PO routing with SIMATIC PDM and for
10-ms time stamp,
CPU 410-5H Process Automation 6ES7654-5CP00-0XF0
electronic manual on CD;
1 600 PO Bundle
module occupies 1 slot
CPU bundle, consisting of
CPU 410-5H Process Automation PS 407 power supply module
and system expansion card for with battery compartment for
1 600 PO 2 backup batteries,
module occupies 2 slots
CPU 410-5H Process Automation 6ES7654-5CQ00-0XF0
PO 2k+ Bundle • 10 A 6ES7407-0KA02-0AA0
CPU bundle, consisting of 120/230 V AC/DC; 5 V DC/10 A,
CPU 410-5H Process Automation 24 V DC/1 A
and system expansion card for • 10 A, redundant 6ES7407-0KR02-0AA0
PO 2k+ ( 2 000) 120/230 V AC/DC; 5 V DC/10 A,
24 V DC/1 A
Sync set
For coupling two redundant CPUs; • 20 A 6ES7407-0RA02-0AA0
for distances up to 120/230 V AC/DC; 5 V DC/20 A,
24 V DC/1 A
• 10 m, consisting of 4 sync 6ES7656-7XX30-0XE0
modules for up to 10 m and PS 405 power supply module
2 fiber-optic sync cables, with battery compartment for
1 m each 2 backup batteries,
• 10 km, consisting of 4 sync 6ES7656-7XX40-0XE0 module occupies 2 slots
modules for up to 10 km • 10 A 6ES7405-0KA02-0AA0
Note: 24 V DC; 5 V DC/10 A,
please order fiber-optic sync 24 V DC/1 A
cables (2 units) in the required • 10 A, redundant 6ES7405-0KR02-0AA0
length separately. 24 V DC; 5 V DC/10 A,
Sync module 24 V DC/1 A
For coupling two redundant CPUs; • 20 A 6ES7405-0RA02-0AA0
2 modules required for each CPU; 24 V DC; 5 V DC/20 A,
for distances up to 24 V DC/1 A;
• 10 m 6ES7960-1AA06-0XA0 with battery compartment for
2 backup batteries,
• 10 km 6ES7960-1AB06-0XA0 module occupies 2 slots
Sync cable (fiber-optic cable) Backup battery 6ES7971-0BA00
For connecting two redundant Type AA, 2.3 Ah
CPUs, 2 cables required for each
redundant automation system Aluminum rack
•1m 6ES7960-1AA04-5AA0 • UR1, 18 slots 6ES7400-1TA11-0AA0
•2m 6ES7960-1AA04-5BA0 • UR2, 9 slots 6ES7400-1JA11-0AA0
• 10 m 6ES7960-1AA04-5KA0 • UR2-H, 6ES7400-2JA10-0AA0
for divided central controllers;
Other lengths On request 2 x 9 slots
Steel rack
• UR1, 18 slots 6ES7400-1TA01-0AA0
• UR2, 9 slots 6ES7400-1JA01-0AA0
• UR2-H, 6ES7400-2JA00-0AA0
for divided central controllers;
2 x 9 slots
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Fault-tolerant automation systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Safety-related automation systems
■ Overview ■ Design
The PROFIsafe profile allows safety-related communication
between the automation system (controller) and the process I/O
via both PROFIBUS and PROFINET. The decision for choosing
either PROFINET IO or the PROFIBUS DP/PA fieldbuses has a
2 significant influence on the architecture of the safety-related
system.
For information on the safety-related design versions with
PROFIBUS DP/PA and PROFINET IO, refer to the section
"Introduction" in the "Safety Integrated for Process Automation"
chapter.
The safety-related SIMATIC PCS 7 automation systems are
based either on the hardware of the AS 410S standard auto-
mation system (F systems) or the hardware of the AS 410H high
availability automation system (FH systems), which have been
supplemented with safety functions using S7 F systems.
In accordance with the design variant, they are categorized as:
• AS Single Station AS 410F
AS Single Station AS 410F with only one CPU (safety-related)
• AS Redundancy Station AS 410FH
Safety-related automation systems are used for critical applica- with two redundant CPUs (safety-related and high availability)
tions where a fault could endanger life or result in damage to the The availability can be flexibly increased with a redundant
plant or the environment. These F/FH systems also referred to as design for the power supply or the Industrial Ethernet communi-
"fail-safe automation systems" detect both faults in the process cations module (for details, see the section "Modular S7-400
and their own internal faults in association with the safety-related systems" under "Flexible and scalable availability").
F modules of the ET 200 distributed I/O systems or fail-safe
transmitters connected directly via the fieldbus. They automati- All AS 410F/FH systems are TÜV-certified and comply with the
cally transfer the plant to a safe state in the event of a fault. safety requirements up to SIL 3 according to IEC 61508.
In these systems with multitasking capability, several programs
can be executed simultaneously in one CPU – basic process
control (BPCS) applications or also safety-related applications.
The programs are reaction-free, i.e. faults in BPCS applications
have no effect on safety-related applications, and vice versa.
Special tasks with very short response times can also be imple-
mented.
The redundant FH systems operating according to the 1-out-of-
2 principle consist of two subsystems of identical design. These
are electrically isolated from each other to achieve optimum
EMC, and are synchronized with each other via fiber-optic ca-
bles. A bumpless switchover is made from the active subsystem
to the standby subsystem in the event of a fault. The two sub-
systems can be present in the same rack or separated by up to
10 km. The spatial separation provides additional security in the
case of extreme influences in the environment of the active
subsystem, e.g. resulting from a fire.
The redundancy of the FH systems is only used to increase the
availability. It is not relevant to processing of the safety functions
and the associated fault detection.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Safety-related automation systems
■ Design (continued)
Individual configuration of AS bundles I/O connection via PROFINET IO
The configuration of the safety-related automation systems and Safety-related AS 410F/FH automation systems can be con-
their article numbers can be defined by selecting pre-configured nected via PROFINET IO with remote I/O stations, for example,
2
ordering units. ET 200M remote I/O stations. Only the PROFINET interface
(2-port switch) integrated in the CPU can be used for this on the
Typical combinations for the respective system can be selected automation system. For additional information, refer to section
using tables in the section "Ordering data". These are divided "Introduction" in the "Safety Integrated for Process Automation"
into: chapter.
• AS Single Station AS 410F with one CPU
Communication over the plant bus
• AS Redundancy Station AS 410FH with two redundant CPUs,
mounted on one common rack (UR2-H) or two separate racks If the PROFINET interface integrated in the CPU of the safety-
(UR2) related automation systems is not used for PROFINET IO, it is
available for connection to the Industrial Ethernet plant bus.
The complete range for selection is available using two corre- Otherwise, the AS 410F and the two subsystems of the
spondingly structured online configurators in the Industry Mall AS 410FH can be connected to the plant bus via one CP 443-1
(www.siemens.com/industrymall): (conformal coating) communication module each.
• SIMATIC PCS 7 AS 410 Single Station configurator
The plant bus can be implemented in the form of a ring structure,
• SIMATIC PCS 7 AS 410 Redundancy Station configurator which can also be configured with redundant architecture if the
System expansion cards including an S7 F systems Runtime availability requirements are high. When there are two redundant
license should be selected here for safety-related AS 410 F/FH rings, it makes sense to use two communication modules per AS
automation systems. (AS 410F) or AS subsystem (AS 410FH) and to distribute their
connections over the two rings (4-way connection).
FO sync cables longer than 1 m must always be ordered Double faults such as failure of the switch on ring 1 with
separately (2 cables required in each case). simultaneous interruption of the bus cable on ring 2 can thus
The components suitable for engineering the safety-related be tolerated.
applications can be ordered in the section "Safety Integrated for Runtime licenses
Process Automation":
• S7 F Systems In the factory state, safety-related automation systems come
F programming tool with F block library for programming with a SIMATIC PCS 7 AS Runtime license for 100 process
safety-related user programs on the engineering system objects (PO), SIMATIC PCS 7 Industry Library Runtime and the
S7 F systems RT license. The 100 POs of the SIMATIC PCS 7
• SIMATIC Safety Matrix AS Runtime license can be expanded by additional Runtime
Convenient safety lifecycle tool for configuration, operation licenses for 100, 1 000 or 10 000 POs. The process objects of
and servicing additional Runtime licenses can be added to process objects
I/O connection via PROFIBUS DP which already exist. The number and type (e.g. 100 or 1 000) of
additional Runtime licenses are irrelevant.
The distributed process I/O can be integrated into a
PROFIBUS DP segment either directly or via a lower-level
PROFIBUS PA fieldbus. Several PROFIBUS DP segments with
distributed process I/Os can be operated on an AS 410F/FH
automation system.
A PROFIBUS DP interface is already integrated in each
CPU 410-5H Process Automation. Using the online configurator
in the Industry Mall or in the selection and ordering data, up to
four additional PROFIBUS DP interfaces can be configured with
additive CP 443-5 PROFIBUS DP interfaces (conformal coating)
for each AS 410F as well as for each subsystem of the
AS 410FH.
Connection of the process I/Os to two redundant PROFIBUS DP
lines of an FH system (AS Redundancy Station) is carried out as
described in the section "High availability automation systems".
The FOUNDATION Fieldbus (FF) H1 and the FF devices are not
supported by Safety Integrated for Process Automation.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Safety-related automation systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Safety-related automation systems
2
Communication module for
S7 F Systems RT License 6ES7833-1CC00-6YX0 connecting SIMATIC S7-400 to
For processing safety-related Industrial Ethernet through TCP/IP,
application programs, for one ISO and UDP;
AS 410F/FH system each PROFINET IO controller, MRP;
CPU 410-5H Process Automation 6ES7410-5HX08-0AB0 integrated real-time switch ERTEC
(conformal coating) with 2 ports;
32 MB RAM integrated 2 x RJ45 interface;
(16 MB each for program and data); S7 communication, open communi-
module occupies 2 slots cation (SEND/RECEIVE) with
FETCH/WRITE, with or without
CPU 410-5H Process Automation 6ES7654-5CJ00-0XF0 RFC 1006, DHCP, SNMP V2,
100 PO Bundle diagnostics, multicast, access
CPU bundle, consisting of protection over IP access list,
CPU 410-5H Process Automation initialization over LAN
and system expansion card for 10/100 Mbit/s;
100 PO with electronic manual on DVD
CPU 410-5H Process Automation 6ES7654-5CL00-0XF0 SIMATIC NET CP 443-5 Extended 6GK7443-5DX05-0XE1
500 PO Bundle (conformal coating)
CPU bundle, consisting of Communication module for
CPU 410-5H Process Automation connection of SIMATIC S7-400 to
and system expansion card for PROFIBUS as DP master or for S7
500 PO communication, for increasing the
number of DP lines, for data set
CPU 410-5H Process Automation 6ES7654-5CN00-0XF0
routing with SIMATIC PDM and for
1 000 PO Bundle
10-ms time stamp,
CPU bundle, consisting of
electronic manual on CD;
CPU 410-5H Process Automation
module occupies 1 slot
and system expansion card for
1 000 PO PS 407 power supply module
with battery compartment for
CPU 410-5H Process Automation 6ES7654-5CP00-0XF0
2 backup batteries,
1 600 PO Bundle
module occupies 2 slots
CPU bundle, consisting of
CPU 410-5H Process Automation • 10 A 6ES7407-0KA02-0AA0
and system expansion card for 120/230 V AC/DC; 5 V DC/10 A,
1 600 PO 24 V DC/1 A
• 10 A, redundant 6ES7407-0KR02-0AA0
CPU 410-5H Process Automation 6ES7654-5CQ00-0XF0 120/230 V AC/DC; 5 V DC/10 A,
PO 2k+ Bundle 24 V DC/1 A
CPU bundle, consisting of
CPU 410-5H Process Automation • 20 A 6ES7407-0RA02-0AA0
and system expansion card for 120/230 V AC/DC; 5 V DC/20 A,
PO 2k+ ( 2 000) 24 V DC/1 A
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Safety-related automation systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
■ Overview ■ Design
With the S7-400 automation systems, which are scalable via Racks
different types of CPU, you have an alternative to AS 410 auto-
mation systems. The systems that can be used in plants with Automation systems based on only one CPU (AS Single Station)
SIMATIC PCS 7 V8.0, V7.1 or V7.0 can be classified as follows: can be mounted on a UR1 rack (18 slots) or UR2 rack (9 slots).
• Standard automation systems The automation systems (AS Redundancy Station) consisting of
two electrically isolated redundant subsystems can be mounted
2
• High availability automation systems on a UR2-H compact rack with divided backplane bus or on two
• Safety-related automation systems separate racks (UR1 or UR2). The design with two racks allows
physical separation of the redundant subsystems, e.g. by a
Standard automation systems fireproof partition and over a distance of up to 10 km. As a result
The AS 414-3, AS 414-3IE, AS 416-2, AS 416-3, AS 416-3IE and of the galvanic isolation, the system is insensitive to electro-
AS 417-4 standard automation systems are extremely robust magnetic interferences.
and feature high processing and communication performance. Redundant power supply
The AS 414-3 and AS 414-3IE are tailored for smaller-scale If you have two separate power supplies for supplying your
applications with smaller quantity structures, which allows for a system, you can increase the availability of the automation
low-cost starter solution with a modular and scalable system systems with redundant power supplies (2 power supplies for
based on the S7-400 controller range. Larger quantity structures one AS Single Station or 1 or 2 power supplies for each sub-
can be implemented using the AS 416-2, AS 416-3/416-3IE and system of an AS Redundancy Station).
AS 417-4 automation systems. These systems are preferred for
medium and large-sized plants. Communication via the Industrial Ethernet (IE) plant bus
High availability automation systems Each standard automation system is connected to the Industrial
Ethernet plant bus by means of a CP 443-1 communication
The aim in using high availability automation systems is to module.
minimize the risk of a production outage. In accordance with
their basic design, these systems are categorized as: If the PN/IE interface integrated in the CPUs of the high avail-
ability and safety-related automation systems is not used for
• AS Single Stations: AS 412-5-1H, AS 414-5-1H, AS 416-5-1H, PROFINET IO, it is available for the connection to the Industrial
and AS 417-5-1H with only one CPU, e.g. for the following Ethernet plant bus. Otherwise, the 1H/F systems (AS Single
applications: Station) and the two subsystems of the 2H/FH systems
- Subsequent expansion to a redundant system (AS Redundancy Station) can be connected to the plant bus via
- Redundant configuration on UR1 racks, comprising 2 Single one CP 443-1 communication module each.
Stations, 4 sync modules, and 2 sync fiber-optic cables
• AS Redundancy Stations: AS 412-5-2H, AS 414-5-2H, I/O connection via PROFIBUS DP
AS 416-5-2H and AS 417-5-2H with two redundant CPUs, The distributed process I/O can be integrated into a
mounted on one common rack (UR2-H) or two separate racks PROFIBUS DP segment either directly or via a lower-level field-
(UR2) bus (PROFIBUS PA or FOUNDATION Fieldbus H1).
Safety-related automation systems Several PROFIBUS DP segments with distributed process I/Os
can be operated on a standard automation system, an 1H/F
Safety-related automation systems (F/FH systems) are available system (AS Single Station), or a 2H/FH system (AS Redundancy
for safety-relevant applications in which an incident can result in Station). The following table provides an overview of the number
danger to persons, plant damage or environmental pollution. and type of configurable PROFIBUS DP interfaces.
These are based on the hardware of the high availability automa-
tion systems, which is expanded by safety functions with I/O connection via PROFINET (PN)
S7 F systems.
Standard automation systems, high availability and safety-
In accordance with the design variant, they are categorized as: oriented automation systems (AS Single Stations and
• AS Single Stations AS Redundancy Stations) can be networked simply and effec-
AS 412F, AS 414F, AS 416F, and AS 417F with only one CPU tively with ET 200M remote I/O stations over PROFINET IO.
(safety-related) If a PN/IE interface is integrated in the CPU of the automation
system (AS 414-3IE, AS 416-3IE, and all H/F/FH systems), then
• AS Redundancy Stations it is to be used for connecting ET 200M remote I/O stations via
AS 412FH, AS 414FH, AS 416FH, and AS 417FH with two PROFINET IO. In standard automation systems, the PN/IE
redundant CPUs (safety-related and high availability) interfaces of type CP 443-1 communication modules can also
The safety-related F/FH systems collaborate with safety-related be used for PROFINET IO.
F modules of the ET 200 distributed I/O systems or fail-safe The maximum availability with minimum error handling times is
transmitters connected directly via the fieldbus to detect not only achieved by the AS Redundancy Station (2 H/FH systems) in
faults in the process, but also their own, internal faults. They conjunction with the system redundancy of the I/O devices.
automatically transfer the plant to a safe state in the event of a System redundancy refers to a type of PROFINET IO communi-
fault. The redundancy of the FH systems is only used to increase cation where each I/O device establishes a communication
the availability. It is not relevant to processing of the safety func- connection to each of the two CPUs of an AS Redundancy
tions and the associated fault detection. Station over the topological network.
All F/FH systems are TÜV-certified and comply with the safety
requirements up to SIL 3 according to IEC 61508.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
2
with SIMATIC PCS 7 AS with SIMATIC PCS 7 AS
Runtime license for 100 POs Runtime license for 100 POs
CPU with 2 DP interfaces CPU with 2 PROFIBUS interfaces
(MPI/DP and slot for IF module) (MPI/DP master and DP master) and
16 MByte main memory 1 PN/IE interface (2 port switch)
(8 MByte each for program and data) 1 MB RAM
(512 KB each for program and data)
Type of delivery
• Individual components, 7 Type of delivery
not pre-assembled • Individual components, 7
• Pre-assembled and tested 8 not pre-assembled
• Pre-assembled and tested 8
Memory card
• Memory card 4 MB RAM C Memory card
(up to approx. 210 POs) • Memory card 1 MB RAM A
• Memory card 8 MB RAM D (up to approx. 30 POs)
(up to approx. 800 POs) • Memory card 2 MB RAM B
• Memory card 16 MB RAM E (up to approx. 100 POs)
(up to approx. 2 100 POs) CPU type
CPU type • CPU 412-5H (up to approx. 30 POs) A
• CPU 416-3 PN/DP J Additive IF 964-DP interface module
(up to approx. 1 200 POs)
• Without additive IF 964-DP 0
Additive IF 964-DP interface module
Interface to Industrial Ethernet
• Without additive IF 964-DP 0 plant bus
• 1 × IF 964-DP 1 • Without interface module 0
Interface to Industrial Ethernet/ • 1 x CP 443-1EX301) 3
PROFINET plant bus • 2 x CP 443-1EX30 for redundant 4
• integrated, without CP 443-1 0 connection1)
• 1 × CP 443-1EX30 3 Racks
• 2 × CP 443-1EX30 4 • UR2 (9 slots), aluminum 3
Racks • UR2 (9 slots), steel 4
• UR2 (9 slots), aluminum 3 • UR1 (18 slots), aluminum 5
• UR2 (9 slots), steel 4 • UR1 (18 slots), steel 6
• UR1 (18 slots), aluminum 5 Power supply
• UR1 (18 slots), steel 6 (without backup batteries)
Power supply • 1 x PS 407, B
(without backup batteries) 10 A for 120/230 V AC/DC
• 1 x PS 407, B • 1 x PS 407, C
10 A for 120/230 V AC/DC 10 A for 120/230 V AC/DC,
optional redundancy
• 1 x PS 407, C
10 A for 120/230 V AC/DC, • 1 x PS 407, D
optional redundancy 20 A for 120/230 V AC/DC
• 1 x PS 407, D • 2 x PS 407, E
20 A for 120/230 V AC/DC 10 A for 120/230 V AC/DC
(redundant)
• 2 x PS 407, E
10 A for 120/230 V AC/DC, • 1 x PS 405, 10 A for 24 V DC G
optional redundancy • 1 x PS 405, 10 A for 24 V DC, H
• 1 x PS 405, 10 A for 24 V DC G optional redundancy
• 1 x PS 405, 10 A for 24 V DC, H • 1 x PS 405, 20 A for 24 V DC J
optional redundancy • 2 x PS 405, 10 A for 24 V DC K
• 1 x PS 405, 20 A for 24 V DC J (redundant)
• 2 x PS 405, 10 A for 24 V DC, K Additive PROFIBUS DP interfaces
optional redundancy • Without CP 443-5 Extended 0
Additive PROFIBUS DP interfaces • 1 x CP 443-5 Extended 1
• Without CP 443-5 Extended 0 • 2 x CP 443-5 Extended1) 2
• 1 x CP 443-5 Extended 1 • 3 x CP 443-5 Extended1) 3
• 2 x CP 443-5 Extended 2 • 4 x CP 443-5 Extended1) 4
• 3 x CP 443-5 Extended 3
• 4 x CP 443-5 Extended1) 4
1) 1)
With the UR2 rack in combination with a redundant power supply, Up to 5 CPs can be plugged into the UR2 rack with a single power supply
the number of additive CP 443-5 Extended is limited to 3. or up to 3 with a redundant power supply.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply 1)
Up to 5 CPs can be plugged into the UR2 rack with a single power supply
or up to 3 with a redundant power supply. or up to 3 with a redundant power supply.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
2
with SIMATIC PCS 7 AS with SIMATIC PCS 7 AS
Runtime license for 100 POs Runtime license for 100 POs
CPU with 2 PROFIBUS interfaces 2 x CPU with 2 PROFIBUS interfaces
(MPI/DP master and DP master) and each (MPI/DP master and DP master)
1 PN/IE interface (2 port switch) and 1 PN/IE interface each
32 MB RAM (2 port switch)
(16 MB each for program and data) 2 x 1 MB RAM
(512 KB each for program and data)
Type of delivery Type of delivery
• Individual components, 7 • Individual components, 7
not pre-assembled not pre-assembled
• Pre-assembled and tested 8 • Pre-assembled and tested 8
Memory card Memory card
• Memory card 4 MB RAM C • 2 x memory card 1 MB RAM A
(up to approx. 210 POs) (up to approx. 30 POs)
• Memory card 8 MB RAM D • 2 x memory card 2 MB RAM B
(up to approx. 800 POs) (up to approx. 100 POs)
• Memory card 16 MB RAM E CPU type
(up to approx. 2 100 POs)
• 2 x CPU 412-5H A
CPU type (up to approx. 30 POs)
• CPU 417-5H M Sync modules and cables
(up to approx. 2 000 POs)
• 2 x 2 sync modules for distances 3
Additive IF 964-DP interface module up to 10 m and 2 x FO sync cable,
• Without additive IF 964-DP 0 1m
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
2
with SIMATIC PCS 7 AS Runtime with SIMATIC PCS 7 AS Runtime
license for 100 POs license for 100 POs
2 x CPU with 2 PROFIBUS interfaces CPU with 2 PROFIBUS interfaces
each (MPI/DP master and DP master) (MPI/DP master and DP master) and
and 1 PN/IE interface each 1 PN/IE interface (2 port switch)
(2 port switch) 1 MB RAM
2 x 32 MB RAM (512 KB each for program and data)
(16 MB each for program and data)
Type of delivery Type of delivery
• Individual components, 7 • Individual components, 7
not pre-assembled not pre-assembled
• Pre-assembled and tested 8 • Pre-assembled and tested 8
Memory card Memory card
• 2 x memory card 4 MB RAM C • Memory card 1 MB RAM A
(up to approx. 210 POs) (up to approx. 30 POs)
• 2 x memory card 8 MB RAM D • Memory card 2 MB RAM B
(up to approx. 800 POs) (up to approx. 100 POs)
• 2 x memory card 16 MB RAM E CPU type
(up to approx. 2 100 POs)
• CPU 412-5H with S7 F Systems B
CPU type RT license (up to approx. 30 POs)
• 2 x CPU 417-5H M Additive interface modules
(up to approx. 2 000 POs)
• Without additive interface module 0
Sync modules and cables
Interface to Industrial Ethernet
• 2 x 2 sync modules for distances 3 plant bus
up to 10 m and 2 x FO sync cable,
1m • Without interface module 0
• 2 x 2 sync modules for 4 • 1 x CP 443-1EX301) 3
up to 10 km and 2 x FO sync cable, • 2 x CP 443-1EX30 4
1 m, for testing for redundant connection1)
Interface to Industrial Ethernet Racks
plant bus • UR2 (9 slots), aluminum 3
• Without interface module 0 • UR2 (9 slots), steel 4
• 2 x CP 443-1EX30 3 • UR1 (18 slots), aluminum 5
for redundant connection1)
• UR1 (18 slots), steel 6
• 2 x 2 CP 443-1EX30 4
for 4-way connection1) Power supply
(without backup batteries)
Racks
• 1 x PS 407, B
• 1 x UR2-H (2 x 9 slots), aluminum 1 10 A for 120/230 V AC/DC
• 1 x UR2-H (2 x 9 slots), steel 2 • 1 x PS 407, C
• 2 x UR2 (9 slots), aluminum 3 10 A for 120/230 V AC/DC,
• 2 x UR2 (9 slots), steel 4 optional redundancy
• 1 x PS 407, D
Power supply 20 A for 120/230 V AC/DC
(without backup batteries)
• 2 x PS 407, E
• 2 x PS 407, B 10 A for 120/230 V AC/DC
10 A for 120/230 V AC/DC (redundant)
• 2 x PS 407, C • 1 x PS 405, 10 A for 24 V DC G
• 10 A for 120/230 V AC/DC,
optional redundancy • 1 x PS 405, 10 A for 24 V DC, H
optional redundancy
• 2 x PS 407, D
20 A for 120/230 V AC/DC • 1 x PS 405, 20 A for 24 V DC J
• 2 x 2 PS 407, E • 2 x PS 405, 10 A for 24 V DC K
10 A for 120/230 V AC/DC (redundant)
(redundant) Additive PROFIBUS DP interfaces
• 2 x PS 405, 10 A for 24 V DC G • Without CP 443-5 Extended 0
• 2 x PS 405, 10 A for 24 V DC, H • 1 x CP 443-5 Extended 1
optional redundancy
• 2 x CP 443-5 Extended1) 2
• 2 x PS 405, 20 A for 24 V DC J
• 3 x CP 443-5 Extended1) 3
• 2 x 2 PS 405, 10 A for 24 V DC K
(redundant) • 4 x CP 443-5 Extended1) 4
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
1) 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply
Up to 5 CPs can be plugged into the UR2 rack with a single power supply
or up to 3 with a redundant power supply. or up to 3 with a redundant power supply.
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
2
mit SIMATIC PCS 7 AS with SIMATIC PCS 7 AS
Runtime License für 100 PO Runtime license for 100 POs
CPU with 2 PROFIBUS interfaces 2 x CPU with 2 PROFIBUS interfaces
(MPI/DP master and DP master) and each (MPI/DP master and DP master)
1 PN/IE interface (2 port switch) and 1 PN/IE interface each
32 MB RAM (2 port switch)
(16 MB each for program and data) 2 x 1 MB RAM
(512 KB each for program and data)
Type of delivery Type of delivery
• Individual components, 7 • Individual components, 7
not pre-assembled not pre-assembled
• Pre-assembled and tested 8 • Pre-assembled and tested 8
Memory card Memory card
• Memory card 4 MB RAM C • 2 x memory card 1 MB RAM A
(up to approx. 210 POs) (up to approx. 30 POs)
• Memory card 8 MB RAM D • 2 x memory card 2 MB RAM B
(up to approx. 800 POs) (up to approx. 100 POs)
• Memory card 16 MB RAM E CPU type
(up to approx. 2 100 POs)
• 2 x CPU 412-5H with S7 F Systems B
CPU type RT license (up to approx. 30 POs)
• CPU 417-5H with S7 F Systems N Sync modules and cables
RT license (up to approx. 2 000 POs)
• 2 x 2 sync modules for distances 3
Additive interface modules • up to 10 m and 2 x FO sync cable,
• Without additive interface module 0 1m
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Complementary S7-400 systems
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
Process I/O
SIMATIC ET 200M for SIMATIC PCS 7
In addition to the standard SIMATIC S7 I/O modules, special I/O
■ Overview modules with diagnostics capability offer the following functions,
among others:
• Channel-based diagnostics, e.g. open-circuit, short-circuit,
limit violations
PROFINET/Industrial Ethernet
SIMATIC PCS 7 process control systems
ET 200M for SIMATIC PCS 7
Interface Modules
■ Overview ■ Function
IM 153-2 High Feature
The IM 153-2 High Feature supports the following functions:
• HART configuring of intelligent field devices
• Configuration of ET 200M I/Os in RUN mode of the automation
system
2
• Connection to redundant automation systems
• Use of ET 200M function modules (controller and counter
modules)
• Operation of up to 12 I/O modules per remote I/O station
• Time stamping (SOE) with the safety-related SM 326F digital
input module (F-DI24)
• Transmission of additional values with HART secondary
variables of the HART SM 331 and SM 332 analog modules
(up to 4 per channel or up to 8 per module)
IM 153-4 PN High Feature
IM 153-2 High Feature interface module for PROFIBUS connection • Integrated 2-port switch
• Baud rate 10 Mbps / 100 Mbps (Autonegotiation/Full Duplex)
Interface module for the PROFIBUS connection
• Operation of up to 12 I/O modules per remote I/O station
The IM 153-2 High Feature interface module (electrical • I&M functions in accordance with PROFIBUS International
PROFIBUS DP transmission mode) is available for connecting Guidelines, order no. 3.502, version V1.1
the ET 200M remote I/O station to the PROFIBUS DP fieldbus.
Depending on the fieldbus configuration (single/redundant), Note:
the ET 200M remote I/O station can be connected via one single
or two redundant interface modules. In order to be able to use the hot swapping function, use of
the active bus module and the mounting rail for hot swapping is
necessary (see under the following section "Accessories").
PROFINET/Industrial Ethernet
SIMATIC ET 200SP
Interface modules without CPU
IM 155-6
■ Overview
• Interface module for linking the ET 200SP to PROFINET or
PROFIBUS
• Handles all data exchange with the controller
■ Technical specifications
6ES7155-6AA00-0BN0 6ES7155-6AU00-0BN0 6ES7155-6AU00-0CN0
IM 155-6 PN ST with BA 2xRJ45 and IM 155-6 PN ST with server module IM 155-6 PN HF with server module
server module
General information
Firmware version V2.2.0
Vendor identification (VendorID) 002AH
Device identifier (DeviceID) 0313H
Product function
• I&M data Yes Yes Yes; I&M0 to I&M4
Engineering with
• STEP 7 TIA Portal can be V11 SP2 with HSP0024 / - V12 / V12 V12 SP1 / V13
configured/integrated as of version
• STEP 7 can be configured/ V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -
integrated as of version
• PROFIBUS as of GSD version/
GSD revision
• PROFINET as of GSD version/ V2.3 / - V1.0 / V2.23 V2.3 / -
GSD revision
Supply voltage
Type of supply voltage 24 V DC DC
Rated value (DC) 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes
Mains buffering
• Mains/voltage failure stored 5 ms 5 ms 5 ms
energy time
Input current
Current consumption, max. 450 mA 450 mA
Inrush current, max. 4.5 A
I²t 0.09 A²·s
Power losses
Power loss, typ. 1.9 W 1.9 W 2.4 W
Address area
Address space per module
• Address space per module, max. 32 byte
Address space per station
• Address space per station, max. 256 byte 256 byte 1 440 byte
Hardware configuration
Rack
• Modules per rack, max. 32 32 64
PROFINET/Industrial Ethernet
SIMATIC ET 200SP
Interface modules without CPU
IM 155-6
2
Interfaces
Number of PROFINET interfaces 1 1 1
Number of PROFIBUS interfaces
1st interface
• Interface types
- Number of ports 2 2 2
- Integrated switch Yes Yes Yes
- RJ 45 (Ethernet) Yes; Pre-assembled bus adapter BA
2x RJ45
- RS 485
- Bus adapter (PROFINET) Yes; Applicable bus adapters: Yes; pplicable bus adapters: Yes; Applicable bus adapters:
BA 2x RJ45, BA 2x FC BA 2x RJ45, BA 2x FC BA 2xRJ45, BA 2xFC, BA 2xSCRJ
(as from FS03)
• Protocols
- PROFINET IO Device Yes Yes Yes
- Open IE communication Yes Yes Yes
- Media redundancy Yes Yes Yes; As MRP or MRPD client; max. 50
or 30 devices in the ring
Interface types
RJ 45 (Ethernet)
• 10 Mbps Yes; for Ethernet services Yes; for Ethernet services Yes; for Ethernet services
• 100 Mbps Yes; PROFINET with 100 Mbit/s full Yes; PROFINET with 100 Mbit/s full Yes; PROFINET with 100 Mbit/s full
duplex (100BASE-TX) duplex (100BASE-TX) duplex (100BASE-TX)
• Transmission procedure PROFINET with 100 Mbit/s full duplex PROFINET with 100 Mbit/s full duplex PROFINET with 100 Mbit/s full duplex
(100BASE-TX) (100BASE-TX) (100BASE-TX)
• Autonegotiation Yes Yes Yes
• Autocrossing Yes Yes Yes
Protocols
PROFINET IO
• Supports protocol for PROFINET IO Yes Yes Yes
PROFINET IO Device
• Services
- Isochronous mode Yes; Bus cycle time: min. 250 µs
- Open IE communication Yes Yes Yes
- IRT, supported Yes; with send cycles of between Yes; with send cycles of between Yes; 250 s, 500 s, 1 ms, 2 ms, 4 ms
250 µs and 4 ms in increments 250 µs and 4 ms in increments additionally with IRT with high perfor-
of 125 µs of 125 µs mance: 250 µs to 4 ms in 125 µs frame
- MRP, supported Yes
- MRPD, supported Yes
- PROFIenergy Yes Yes
- Prioritized startup Yes Yes Yes
- Shared device Yes Yes Yes
- Number of IO controllers with 2 4
shared device, max.
Open IE communication
• TCP/IP Yes Yes Yes
• SNMP Yes Yes Yes
• LLDP Yes Yes Yes
Isochronous mode
Isochronous operation (application Yes
synchronized up to terminal)
equidistance Yes
shortest clock pulse 250 µs
max. cycle 4 ms
Jitter, max. 1 µs
Interrupts/diagnostics/
status information
Status indicator Yes Yes Yes
Alarms
• Alarms Yes Yes Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200SP
Interface modules without CPU
IM 155-6
2
Diagnostic messages
• Diagnostic functions Yes Yes Yes
Diagnostics indication LED
• RUN LED Yes; Green LED Yes; Green LED Yes; Green LED
• ERROR LED Yes; Red LED Yes; Red LED Yes; Red LED
• MAINT LED Yes; yellow LED Yes; yellow LED Yes; yellow LED
• Monitoring the supply voltage Yes; Green LED Yes; Green LED Yes; Green LED
(PWR-LED)
• Connection display LINK TX/RX Yes Yes; 2x green LED Yes; 2x green LED
• Connection display DP
Galvanic isolation
between backplane bus No
and electronics
between PROFINET Yes Yes Yes
and all other circuits
between supply and all other circuits Yes Yes Yes
Permissible potential difference
between different circuits 75 V DC / 60 V AC 75 V DC/60 V AC (base isolation) 75 V DC/60 V AC (base isolation)
Isolation
Isolation checked with 707 V DC between supply voltage and 707 V DC between supply voltage and 707 V DC between supply voltage and
electronics; electronics (type test); electronics (type test);
1 500 V AC between Ethernet and 1 500 V AC between Ethernet and 1 500 V AC between Ethernet and
electronics electronics (type test) electronics (type test)
Standards, approvals, certificates
Network loading class 3 3 3
Security level According to Security Level 1 Test According to Security Level 1 Test According to Security Level 1 Test
Cases V1.1.1 Cases V1.1.1 Cases V1.1.1
Dimensions
Width 50 mm 50 mm 50 mm
Height 117 mm 117 mm 117 mm
Depth 74 mm 74 mm 74 mm
Weights
Weight, approx. 191 g; IM155PN ST with BA 2x RJ45 147 g; without bus adapter 147 g; without bus adapter
(mounted)
PROFINET/Industrial Ethernet
SIMATIC ET 200SP
Interface modules without CPU
IM 155-6
Digital output module DQ 8x24 V DC/ 6ES7132-6BF00-0BA0 Communication module CM 1xPtP 6ES7137-6AA00-0BA0
0.5 A Standard, BU type A0, color Standard, for serial communication
code CC02 connections with RS232 and RS422
interfaces. RS485, BU type A0, color
Digital output module DQ 8x24 V DC/ 6ES7132-6BF00-0CA0 code CC00
0.5 A High Feature, BU type A0, color
code CC02 CM 4xIO-Link Master V1.1 Standard 6ES7137-6BD00-0BA0
communication module, for connect-
Digital output module DQ 8x24 V DC/ 6ES7132-6BF60-0AA0 ing up to 4 IO-Link devices, time-
0.5 A Sink output, Basic, BU type A0, based IO, BU type A0, color code
color code CC01 CC04
Digital output module DQ 16x24 V DC/ 6ES7132-6BH00-0BA0 CM AS-i Master ST communication 3RK7137-6SA00-0BC1
0.5 A Standard, BU type A0, color module, BU type C0 or C1,
code CC00 color code CC00
Relay module RQ NO 4x120 V DC - 6ES7132-6HD00-0BB0 Special modules
230 V AC/5 A Standard, normally-
open, BU type B0, color code CC00 Fail-safe power module F-PM-E 24 V 6ES7136-6PA00-0BC0
DC/8 A PPM Standard, BU type C0,
Signal relay module RQ CO 6ES7132-6GD50-0BA0 color code CC52. 2 inputs, 1 output,
4x24 V UC/2 A Standard, SIL3/Cat.4/PLe
changeover contact, BU type A0,
color code CC00 BusAdapter BA 2xRJ45 6ES7193-6AR00-0AA0
PROFINET/Industrial Ethernet
SIMATIC ET 200SP
Interface modules without CPU
IM 155-6
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with CPU
IM 151-8 PN/DP CPU
■ Overview
• Interface module for SIMATIC ET 200S with integrated
CPU S7-314
• For high-performance control solutions in ET 200S
• Increase of the availability of systems and machines
• PROFINET IO Controller for up to 128 IO Devices
2
• PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
PROFINET IO controller
• PROFINET interface with integrated 3-port switch
• Isochronous mode on PROFINET
• With many communication options: PG/OP communication,
PROFINET IO, PROFINET CBA, open IE communication (TCP,
ISO-on-TCP and UDP), web server and S7-communication
(with loadable FBs)
• Fast, simple and end-to-end programming of a system with
modular programs via STEP 7
• Compact SIMATIC Micro Memory Card (MMC)
• Optional PROFIBUS master for 32 PROFIBUS DP slaves
(with master interface 6ES7138-4HA00-0AB0)
• Fail-safe IM 151-8F PN/DP CPU PROFIsafe available
Note:
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
6ES7151-8AB01-0AB0 6ES7151-8AB01-0AB0
IM 151-8 PN/DP CPU IM 151-8 PN/DP CPU
General information Address area
Engineering with I/O address area
• Programming package STEP7 V 5.5 or higher • Inputs 2 048 byte
Supply voltage • Outputs 2 048 byte
24 V DC Yes Process image
Power losses • Inputs, adjustable 2 048 byte
Power loss, typ. 5.5 W • Outputs, adjustable 2 048 byte
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with CPU
IM 151-8 PN/DP CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with CPU
Master interface module for IM 151 CPU interface modules
■ More information
Brochures
Information material for downloading can be found
in the Internet:
http://www.siemens.com/simatic/printmaterial
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with fail-safe CPU
IM 151-8 F PN/DP CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with fail-safe CPU
IM 151-8 F PN/DP CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules with fail-safe CPU
IM 151-8 F PN/DP CPU
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
2)
An MMC is essential for operating the CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules without CPU
IM 151-3 PN
2
PROFINET
High Feature
General information
Vendor identification (VendorID) 002AH 002AH
Device identifier (DeviceID) 0301H 0301H
Supply voltage
Mains buffering
• Mains buffering, min. 20 ms 20 ms
Address area
Addressing volume
• Inputs 256 byte 256 byte
• Outputs 256 byte 256 byte
Interfaces
Supports protocol for PROFINET IO
• RJ45 Yes Yes
• Interface module for linking the ET 200S to PROFINET Protocols
• Handles all data exchange with the PROFINET I/O Controller Supports protocol for PROFINET IO Yes Yes
• 3 versions: Isochronous mode
- IM151-3 PN STANDARD Isochronous operation (application No No
- IM151-3 PN HIGH FEATURE and IM 151-3 PN FO: synchronized up to terminal)
supports, in contrast to the STANDARD version, Interrupts/diagnostics/
the operation of PROFIsafe F modules status information
Alarms
• with integrated 2-port switch for line topology
• Alarms Yes Yes
• Delivery including connecting module
Diagnostic messages
Note: • Diagnostic functions Yes Yes
Micro Memory Card required for operation depending on the Diagnostics indication LED
configuration. • Bus fault BF (red) Yes Yes
• Group error SF (red) Yes Yes
• Monitoring 24 V voltage supply ON Yes Yes
(green)
• Connection to network LINK (green) Yes Yes
• Transmit/receive RX/TX (yellow) Yes Yes
Galvanic isolation
between backplane bus No No
and electronics
between supply voltage No No
and electronics
between Ethernet and electronics Yes Yes
Dimensions
Width 60 mm 60 mm
Height 119.5 mm 119.5 mm
Depth 75 mm 75 mm
Weights
Weight, approx. 120 g 135 g
PROFINET/Industrial Ethernet
SIMATIC ET 200S
Interface modules without CPU
IM 151-3 PN
IM 151-3 PN interface module 6ES7151-3AA23-0AB0 MMCs for storing the device name
For ET 200S; MMC 64 kByte 1) 6ES7953-8LF30-0AA0
transfer rates up to 100 Mbit/s;
MMC 128 kByte 1) 6ES7953-8LG30-0AA0
2
data volume depends on the
number of modules inserted, MMC 512 kByte 1) 6ES7953-8LJ30-0AA0
up to 63 modules can be connected,
bus connection through RJ45 MMCs for storing the device name and/or firmware update
IM 151-3 PN PROFINET 6ES7151-3BA23-0AB0 MMC 2 MByte 1) 6ES7953-8LL31-0AA0
High Feature interface module MMC 4 MByte 1) 6ES7953-8LM31-0AA0
for ET 200S; MMC 8 MByte 1) 6ES7953-8LP31-0AA0
transfer rate up to 100 Mbit/s;
max. 63 modules up to 2 m wide ET 200S distributed I/O
can be connected; bus connection system manuals
via RJ45, incl. termination module are available on the Internet http://www.siemens.com/simatic-
IM 151-3 FO interface module 6ES7151-3BB23-0AB0 as PDF files: doku
for ET 200S; SIMATIC Manual Collection 6ES7998-8XC01-8YE0
with 2 PROFINET FO-interfaces and Electronic manuals on DVD,
integrated 2-port switch, multi-language:
max. 63 modules up to 2 m wide S7-200, TD 200, S7-300, M7-300,
can be connected, C7, S7-400, M7-400, STEP 7, Engi-
incl. termination module neering Tools, Runtime Software,
Accessories SIMATIC DP (Distributed I/O),
SIMATIC HMI (Human Machine
Industrial Ethernet FC RJ45 Interface), SIMATIC NET (Industrial
Plug 90 Communication)
RJ45 plug connector SIMATIC Manual Collection – 6ES7998-8XC01-8YE2
for Industrial Ethernet with a rugged Update service for 1 year
metal enclosure and integrated
insulation displacement contacts Scope of delivery: Current DVD
for connecting Industrial Ethernet "S7 Manual Collection" and the
FC installation cables; three subsequent updates
with 90° cable outlet Label sheets DIN A4 (10 pieces)
1 unit 6GK1901-1BB20-2AA0 Each sheet contains 60 labeling strips
10 units 6GK1901-1BB20-2AB0 for peripheral modules and 20 label-
ing strips for interface modules
50 units 6GK1901-1BB20-2AE0 • petrol 6ES7193-4BH00-0AA0
Industrial Ethernet FastConnect • red 6ES7193-4BD00-0AA0
installation cables • yellow 6ES7193-4BB00-0AA0
Fast Connect standard cable 6XV1840-2AH10 • light beige 6ES7193-4BA00-0AA0
Fast Connect trailing cable 6XV1840-3AH10 Termination module 6ES7193-4JA00-0AA0
Fast Connect marine cable 6XV1840-4AH10 as spare part for ET 200S
Termination Kits Power supply connector
SC RJ POF Plug 6GK1900-0ML00-0AA0 Spare part; for connecting the
Assembly case for on-site assembly 24 V DC supply voltage
of SC RJ plugs consisting of strip- • with push-in terminals 6ES7193-4JB00-0AA0
ping tool, kevlar cutter, microscope, • with screw-type terminals 6ES7193-4JB50-0AA0
abrasive paper, grinding support
DIN rail 35 mm
IE SC RJ POF Plug 6GK1900-0MB00-0AC0
• Length: 483 mm for 19" cabinets 6ES5710-8MA11
Screw-in plug for on-site assembly
to POF fiber optic cable • Length: 530 mm 6ES5710-8MA21
(1 pack = 20 units) for 600 mm cabinets
• Length: 830 mm 6ES5710-8MA31
IE SC RJ Refill Set POF 6GK1900-0MN00-0AA0 for 900 mm cabinets
Refill set for Termination Kit SC RJ • Length: 2 m 6ES5710-8MA41
POF Plug, consisting of abrasive
paper and grinding plate (set of 5) Industrial Ethernet Switches
SC RJ POF Plug 6GK1900-0NL00-0AA0 Managed Industrial Ethernet
Assembly case for on-site assembly Switches; Isochronous real time,
of SC RJ plugs consisting of strip- LED diagnostics, fault signaling
ping tool, buffer stripping tool, kev- contact with SET button,
lar cutter, fiber breaking tool, redundant power supply
microscope • SCALANCE X202-2P IRT; 6GK5202-2BH00-2BA3
2 x 10/100 Mbit/s RJ45 ports,
Industrial Ethernet SC RJ PCF Plug 6GK1900-0NB00-0AC0 2 x 100 Mbit/s POF/PCF SC RJ
Screw-in plug for on-site assembly
to PCF fiber optic cable • SCALANCE X201-3P IRT; 6GK5201-3BH00-2BA3
(1 pack = 10 units) 1 x 10/100 Mbit/s RJ45 ports,
3 x 100 Mbit/s POF/PCF SC RJ
Industrial Ethernet Fast Connect 6GK1901-1GA00 • SCALANCE X200-4P IRT; 6GK5200-4AH00-2BA3
stripping tool 4 x 100 Mbit/s POF/PCF SC RJ
1)
For operating the IM 151-3, an MMC is essential
■ More information
Brochures
Information material for downloading can be found
in the Internet:
http://www.siemens.com/simatic/printmateria
PROFINET/Industrial Ethernet
SIMATIC ET 200MP
Interface modules
IM 155-5 PN
■ Overview
• Prioritized fast startup (FSU) with 500 ms
(max. 12 I/O modules)
• Media Redundancy Protocol (MRP)
• Shared device on up to two I/O controllers (when configuring
using GSD file; depends on the respective configuration tool) 2
• Omission of SIMATIC memory card (SMC); IM replacement
without PG using LLDP
Starting from FW version V2.0.0, the IM155-5 PN ST interface
module supports the following new functions:
• Submodule-granular shared device with up to two I/O
controllers
• Configuration control (option handling)
• Module-internal shared input and output (MSI/MSO), i.e. the
inputs or outputs of a module can be made available simulta-
neously to up to two I/O controllers
The IM155-5 PN HF interface module has the following
additional functions:
• Interface modules for linking the ET 200MP to PROFINET • Shared device on up to 4 IO controllers
• These handle data exchange with the PROFINET I/O controller • Module-internal shared input and output (MSI/MSO) on up to
in the PLC four IO controllers
• Integrated 2-port switch for line topology • Operation on a highly available SIMATIC S7-400H
• Max. 30 I/O modules • Support for the MRPD function (media redundancy with
• Shortest bus cycle 250 µs planned duplication)
• Linking to the isochronous task of the CPU
■ Technical specifications
6ES7155-5AA00-0AB0 6ES7155-5AA00-0AC0
IM 155-5 PN ST IM 155-5 PN HF
General information
Product function
• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
Engineering with
• STEP 7 TIA Portal can be V13 / V13 V13 / V13
configured/integrated as of version
• STEP 7 can be V5.5 SP3 / - V5.5 SP3 / -
configured/integrated as of version
• PROFINET V2.3 / - V2.3 / -
as of GSD version/GSD revision
Supply voltage
Type of supply voltage DC DC
Rated value (DC) 24 V 24 V
Reverse polarity protection Yes Yes
Short-circuit protection Yes Yes
Mains buffering
• Mains/voltage failure stored energy 5 ms 5 ms
time
Hardware configuration
Integrated power supply Yes
Rack
• Modules per rack, max. 30; I/O modules 30; I/O modules
Interfaces
Number of PROFINET interfaces 1 1
1st interface
• Interface types
- Number of ports 2 2
- Integrated switch Yes Yes
- RJ 45 (Ethernet) Yes Yes
• Protocols
- PROFINET IO Device Yes Yes
- Media redundancy Yes Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200MP
Interface modules
IM 155-5 PN
2 RJ 45 (Ethernet)
• 10 Mbps No
• 100 Mbps Yes Yes
• Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX)
• Autonegotiation Yes Yes
• Autocrossing Yes Yes
Protocols
PROFINET IO Yes Yes
PROFINET IO Device
• Services
- Isochronous mode Yes Yes
- IRT, supported Yes Yes
- MRP, supported Yes Yes
- MRPD, supported Yes
- PROFINET system redundancy Yes
- Prioritized startup Yes Yes
- Shared device Yes Yes
- Number of IO controllers with 2 4
shared device, max.
Open IE communication
• TCP/IP Yes Yes
• SNMP Yes Yes
• LLDP Yes Yes
Isochronous mode
Isochronous operation (application Yes Yes
synchronized up to terminal)
equidistance Yes Yes
shortest clock pulse 250 µs 250 µs
max. cycle 4 ms 4 ms
Interrupts/diagnostics/
status information
Status indicator Yes Yes
Alarms
• Alarms Yes Yes
Diagnostic messages
• Diagnostic functions Yes Yes
Diagnostics indication LED
• RUN LED Yes; Green LED Yes; Green LED
• ERROR LED Yes; Red LED Yes; Red LED
• MAINT LED Yes; yellow LED Yes; yellow LED
• Connection display LINK TX/RX Yes; yellow LED Yes; yellow LED
Isolation
Isolation checked with 707 V DC (type test) 707 V DC (type test)
Dimensions
Width 35 mm 35 mm
Height 147 mm 155 mm
Depth 129 mm 120 mm
Weights
Weight, approx. 310 g 350 g
PROFINET/Industrial Ethernet
SIMATIC ET 200MP
Interface modules
IM 155-5 PN
2
installation on S7-1500 mounting rail IE FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible;
IM 155-5 PN ST, standard version 6ES7155-5AA00-0AB0 with UL approval;
IM 155-5 PN HF, High Feature 6ES7155-5AA00-0AC0 Sold by the meter,
version with additional functions max. length 1000 m;
Accessories minimum order 20 m
PROFINET/Industrial Ethernet
SIMATIC ET 200M
Interface modules
IM 153-4 PN
■ Overview
• To connect ET 200M to PROFINET IO (via copper line, RJ45)
as an IO device
• 2 versions:
2
- IM 153-4 PN STANDARD
- IM 153-4 PN HIGH FEATURE:
supports, in contrast to the STANDARD version, the
operation of PROFIsafe F and HART modules. The operation
of an S7-400H (system redundancy) is likewise possible.
• Integrated 2-port switch
• 12 modules per station
• Usable I/O capacity: 192 bytes each
• Active bus backplane to hot-swap modules available as an
option
• Baud rate 10 Mbit/s / 100 Mbit/s (autonegotiation / full duplex)
• I&M functions according to PNO-Guideline Order-No. 3.502,
Version V1.1
Note:
Micro Memory Card with at least 64 KB required if not all the
stations in the network support LLDP (Link Layer Discovery
Protocol; proximity detection).
■ Technical specifications
6ES7153-4AA01-0XB0 6ES7153-4BA00-0XB0
IM 153-4 PN STANDARD IM 153-4 PN HIGH FEATURE
General information
Vendor identification (VendorID) 002AH 002AH
Device identifier (DeviceID) 0302H 0302H
Supply voltage
24 V DC Yes Yes
permissible range, lower limit (DC) 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V
permissible range (ripple included), 20.4 V 18.5 V
lower limit (DC)
permissible range (ripple included), 28.8 V 30.2 V
upper limit (DC)
External protection for supply cables In a construction with grounded reference potential, In a construction with grounded reference potential,
(recommendation) a fuse is necessary for redundant interface modules a fuse is necessary for redundant interface modules
(Recommendation: 2.5 A) (Recommendation: 2.5 A)
Mains buffering
• Mains/voltage failure stored energy 5 ms 5 ms
time
Input current
Current consumption, max. 600 mA 600 mA
Inrush current, typ. 4A 4A
I²t 0.09 A²·s 0.09 A²·s
PROFINET/Industrial Ethernet
SIMATIC ET 200M
Interface modules
IM 153-4 PN
2
Rated value (DC) 5V 5V
Rated value, 5 V DC Yes Yes
Output current
for backplane bus (5 V DC), max. 1.5 A 1.5 A
Power losses
Power loss, typ. 6W 6W
Address area
Addressing volume
• Inputs 192 byte 672 byte; Extended HART user data
• Outputs 192 byte 192 byte
Hardware configuration
Number of modules per DP slave 12 12
interface, max.
1st interface
PROFINET IO Controller
• Services
- PROFINET system redundancy Yes
Communication functions
Bus protocol/transmission protocol PN IO PN IO
Interrupts/diagnostics/status infor-
mation
Diagnostics indication LED
• Connection to network LINK (green) Yes Yes
• Transmit/receive RX/TX (yellow) Yes Yes
Isolation
Isolation checked with 500 V DC Between PROFINET and 24 V supply: 1 500 V AC,
between functional grounding and 24 V supply: 500 V DC
Degree and class of protection
IP20 Yes Yes
Ambient conditions
Operating temperature
• Min. 0 °C 0 °C
• max. 60 °C 60 °C
Air pressure
• Operating altitude above sea level, 2 000 m 2 000 m
max.
Dimensions
Width 40 mm 40 mm
Height 125 mm 125 mm
Depth 118 mm 118 mm
Weights
Weight, approx. 215 g 215 g
PROFINET/Industrial Ethernet
SIMATIC ET 200M
Interface modules
IM 153-4 PN
2
S7-200, TD 200, S7-300, M7-300,
Standard 6ES7153-4AA01-0XB0 C7, S7-400, M7-400, STEP 7,
High Feature 6ES7153-4BA00-0XB0 Engineering Tools, Runtime Soft-
ware, SIMATIC DP (Distributed I/O),
Accessories SIMATIC HMI (Human Machine
Interface), SIMATIC NET (Industrial
Bus modules for ET 200M
Communication)
• To accommodate a power supply 6ES7195-7HA00-0XA0
and an IM 153 module for the S7 Manual Collection 6ES7998-8XC01-8YE2
hot-swapping function during update service for 1 year
RUN, incl. bus module cover
Scope of delivery:
• To accommodate two 40-mm wide 6ES7195-7HB00-0XA0 Current DVD "S7 Manual Collection"
I/O modules for the hot-swapping and the three subsequent updates
function
• To accommodate one 80-mm wide 6ES7195-7HC00-0XA0 Industrial Ethernet FC RJ45
I/O module for the hot-swapping Plug 180
function RJ45 plug connector for
SIMATIC Micro Memory Card Industrial Ethernet with a rugged
metal housing and integrated
64 KB1) 6ES7953-8LF30-0AA0 insulation displacement contacts
for connecting Industrial Ethernet
SIMATIC DP DIN rail for ET 200M
FC installation cables;
Accommodates with 180° cable outlet
up to 5 bus modules;
1 unit 6GK1901-1BB10-2AA0
for hot-swapping function
• Length: 483 mm (19“) 6ES7195-1GA00-0XA0 10 units 6GK1901-1BB10-2AB0
• Length: 530 mm 6ES7195-1GF30-0XA0 50 units 6GK1901-1BB10-2AE0
• Length: 620 mm 6ES7195-1GG30-0XA0
Industrial Ethernet FastConnect
• Length: 2 000 mm 6ES7195-1GC00-0XA0
installation cables
SIMATIC S7-300 mounting rail • Fast Connect standard cable 6XV1840-2AH10
Length: 160 mm 6ES7390-1AB60-0AA0 • Fast Connect trailing cable 6XV1840-3AH10
• Fast Connect marine cable 6XV1840-4AH10
Length: 480 mm (19“) 6ES7390-1AE80-0AA0
Industrial Ethernet FastConnect
Length: 530 mm 6ES7390-1AF30-0AA0
Stripping Tool 6GK1901-1GA00
Length: 830 mm 6ES7390-1AJ30-0AA0
Length: 2000 mm 6ES7390-1BC00-0AA0
Power supply connector
For connection of the 24 V DC
power supply;
spare part,
1 pack containing 10 units
Spring-loaded connection 6ES7193-4JB00-0AA0
Screw terminal connections 6ES7193-4JB50-0AA0
1) To operate the IM153-4, an MMC is required with at least 64 KB memory.
Cards with higher memory capacity may also be used.
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-4 PN
■ Overview
Interface module for processing the communication between
ET 200pro and a higher-level controller over PROFINET IO.
■ Technical specifications
6ES7154-4AB10-0AB0 6ES7154-4AB10-0AB0
IM 154-4 PN High Feature IM 154-4 PN High Feature
General information Interrupts/diagnostics/
Vendor identification (VendorID) 0x002A status information
Diagnostics indication LED
Device identifier (DeviceID) 0x0305
• Bus fault BF (red) Yes; Additional LEDs (MAINT, P1/2
Supply voltage LINK, P1/2 RX/TX) available
24 V DC Yes • Group error SF (red) Yes
permissible range, lower limit (DC) 20.4 V • Monitoring 24 V voltage supply ON Yes
(green)
permissible range, upper limit (DC) 28.8 V • Load voltage monitoring DC 24 V Yes
Load voltage 1L+ (green)
• Rated value (DC) 24 V Parameter
• Short-circuit protection Yes; Diagnostic alarm 1
Fuse in lower part is exchangeable,
the fuse on the IM-LP is not Hardware interrupt 1
• Reverse polarity protection Yes; Swapping interrupt 1
against destruction
identifier-related diagnostic data 1
Input current
Module status 1
from supply voltage 1L+, max. 400 mA;
Dependent on terminal module, typ. Channel-related diagnostics 1
maximum value for FO connection
method, full load on RWB and Startup if setpoint not equal to actual 1
20.4 V input voltage configuration
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-4 PN
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-4 PN
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 PN/DP CPU
2 Engineering with
• Programming package STEP7 V 5.5 or higher
Supply voltage
24 V DC Yes
Power losses
Power loss, typ. 8.5 W
Memory
Work memory
• integrated 384 kbyte
Load memory
• pluggable (MMC), max. 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs
for word operations, typ. 0.09 µs
• CPU with PLC functionality equivalent to S7-315-2 PN/DP for fixed point arithmetic, typ. 0.12 µs
provides distributed intelligence for preprocessing
for floating point arithmetic, typ. 0.45 µs
• Interface module for exchanging pre-processed I/O data
Counters, timers and their retentiv-
between the ET 200pro and a higher-level master/IO ity
Controller via PROFIBUS DP/PROFINET IO S7 counter
• PROFINET IO Controller to operate distributed I/Os on • Number 256
PROFINET IEC counter
• Component based Automation (CBA) on PROFINET • present Yes
• PROFINET proxy for intelligent devices on PROFIBUS DP in S7 times
Component Based Automation (CBA) • Number 256
• PROFINET interface with 3-port switch IEC timer
• Isochronous mode on PROFIBUS or PROFINET • present Yes
• Integrated web server with the option of creating user-defined Data areas and their retentivity
web pages Flag
• Number, max. 2 048 byte
• CPU with PLC functionality equivalent to S7-315-2 PN/DP
provides distributed intelligence for preprocessing Address area
I/O address area
• Interface module to exchange preprocessed I/O data from
• Inputs 2 048 byte
ET 200pro with a higher-level master through PROFIBUS DP
• Outputs 2 048 byte
• Fast, simple and end-to-end programming of a system with
modular programs via STEP 7 Process image
• Inputs, adjustable 2 048 byte
• Fail-safe IM 154-8F PN/DP CPU PROFIsafe available • Outputs, adjustable 2 048 byte
Note: Time of day
Clock
Micro Memory Card required for operation of CPU.
• Hardware clock (real-time clock) Yes
Operating hours counter
• Number 1
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 PN/DP CPU
2
Interface type Integrated RS 485 interface PG/OP communication Yes
Physics RS 485/connection: Global data communication
2 x M12 b-coded • supported Yes
Functionality S7 basic communication
• MPI Yes • supported Yes
• DP master Yes
S7 communication
• DP slave Yes
• supported Yes
• Point-to-point connection No
Open IE communication
DP master
• TCP/IP Yes;
• Number of DP slaves, max. 124 via integrated PROFINET interface
2nd interface and loadable FBs
Interface type PROFINET - Number of connections, max. 8
Physics Ethernet • ISO-on-TCP (RFC1006) Yes
(2 x M12 d-coded; 1 x RJ45) - Number of connections, max. 8
Number of ports 3 • UDP Yes
Functionality - Number of connections, max. 8
• MPI No Web server
• DP master No • supported Yes
• DP slave No Configuration
• PROFINET IO Controller Yes; Also simultaneously programming
with IO-Device functionality
• Programming language
• PROFINET IO Device Yes; Also simultaneously
with IO Controller functionality - LAD Yes
• PROFINET CBA Yes - FBD Yes
- STL Yes
PROFINET IO Controller - SCL Yes
• Max. number of connectable IO 128 - CFC Yes
devices for RT
- GRAPH Yes
• Number of IO devices with IRT 128
and the option "high flexibility" - HiGraph® Yes
• Number of IO Devices with IRT 64 Know-how protection
and the option "high performance", • User program protection/password Yes
max. protection
Isochronous mode • Block encryption Yes; With S7 block Privacy
Isochronous operation Yes; Dimensions
(application synchronized Via PROFIBUS DP or
Width 135 mm
up to terminal) PROFINET interface
Height 130 mm
Depth 65 mm;
60 mm without cover for RJ45 socket;
65 mm with cover for RJ45 socket
Weights
Weight, approx. 720 g
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 PN/DP CPU
2
for operating distributed I/Os on • Preassembled IE FC TP
PROFINET, with integrated PLC Trailing Cable GP 2 x 2
functionality. (PROFINET Type C) with two
Accessories 4-pin M12 plugs (4-pin, D-coded),
degree of protection IP65/IP67,
MMC for program backup in various lengths:
MMC 64 Kbyte 1) 6ES7953-8LF30-0AA0 - 0.3 m 6XV1870-8AE30
- 0.5 m 6XV1870-8AE50
MMC 128 Kbyte 1) 6ES7953-8LG30-0AA0 - 1.0 m 6XV1870-8AH10
MMC 512 Kbyte 1) 6ES7953-8LJ30-0AA0 - 1.5 m 6XV1870-8AH15
MMC 4 Mbyte 1) 6ES7953-8LM31-0AA0 - 2.0 m 6XV1870-8AH20
- 3.0 m 6XV1870-8AH30
MMC 8 Mbyte 1) 6ES7953-8LP31-0AA0 - 5.0 m 6XV1870-8AH50
MMC for program backup and/or firmware updates - 10 m 6XV1870-8AN10
MMC 2 Mbyte 1) 6ES7953-8LL31-0AA0 - 15 m 6XV1870-8AN15
• PROFINET M12 connecting cable,
Connection module 6ES7194-4AN00-0AA0 trailing cable preassembled at
For CPU IM154-8 PN/DP, both ends with angled
with 4 x M12 and 2 x 7/8", M12 connectors (male insert),
for connecting PROFINET and in various lengths:
PROFIBUS DP. - 3.0 m 3RK1902-2NB30
- 5.0 m 3RK1902-2NB50
SCALANCE X-200
Industrial Ethernet Switches - 10 m 3RK1902-2NC10
• PROFINET M12 connecting cable,
With integral SNMP access, 6GK5208-0HA00-2AA6 trailing cable preassembled
Web diagnostics, copper cable at one end with angled
diagnostics and PROFINET M12 connector (male insert at one
diagnostics, for setting up linear, end, other end open),
star and ring structures in various lengths:
SCALANCE X208PRO, - 3.0 m 3RK1902-2HB30
in degree of protection IP65,
with eight 10/100 Mbit/s M12 ports, - 5.0 m 3RK1902-2HB50
incl. eleven M12 dust caps. - 10 m 3RK1902-2HC10
Industrial Ethernet FC RJ45 IE FC M12 Plug PRO
Plug 180
PROFINET M12 plug connector,
RJ45 plug connector for Industrial D-coded with fast connection
Ethernet with a rugged metal system, axial cable outlet.
enclosure and integrated insulation • 1 unit 6GK1901-0DB20-6AA0
displacement contacts for • 8 units 6GK1901-0DB20-6AA8
connecting Industrial Ethernet FC
installation cables; • PROFINET M12 plug connector, 3RK1902-2DA00
with 180° cable outlet D-coded, angled.
• 1 unit 6GK1901-1BB10-2AA0 IE panel feedthrough
• 10 units 6GK1901-1BB10-2AB0 Cabinet feedthrough for converting 6GK1901-0DM20-2AA5
• 50 units 6GK1901-1BB10-2AE0 from the M12 connection system
(D-coded, IP65/IP67) to the RJ45
Industrial Ethernet Fast Connect
connection system (IP20),
installation cables
1 pack = 5 units.
• FastConnect Standard Cable 6XV1840-2AH10
• FastConnect Trailing Cable 6XV1840-3AH10
• FastConnect Marine Cable 6XV1840-4AH10
Industrial Ethernet
FastConnect installation cables
• IE FC TP Trailing Cable GP 2 x 2; 6XV1870-2D
sold by the meter,
max. delivery unit 1 000 m;
minimum order quantity 20 m.
• IE TP Torsion Cable GP 2 x 2; 6XV1870-2F
sold by the meter,
max. delivery unit 1 000 m;
minimum order quantity 20 m.
Industrial Ethernet Fast Connect
Stripping Tool 6GK1901-1GA00
1)
An MMC is essential for operating the CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 PN/DP CPU
1)
An MMC is essential for operating the CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 F PN/DP CPU
■ Overview
• Interface module for SIMATIC ET 200pro with integrated
fail-safe CPU
• CPU with PLC functionality equivalent to CPU S7-315F PN/DP;
2
with distributed intelligence for preprocessing
• For constructing a fail-safe automation system for plants with
increased safety requirements
• Complies with safety requirements up to SIL 3 according to
IEC 61508, IEC 62061 and PLe according to
ISO 13849.1:2006
• For high-performance control solutions in ET 200pro
• Increase of the availability of systems and machines
• Integral Web server with the option of creating user-defined
Web sites
• Isochronous mode on PROFIBUS or PROFINET
• PROFINET IO Controller for up to 128 IO Devices
• PROFINET interface with integrated 3-port switch
• With many communication options:
PG/OP communication, PROFINET IO, PROFINET CBA,
open IE communication (TCP, ISO-on-TCP and UDP),
web server and S7-communication (with loadable FBs)
• Fast, simple and end-to-end programming of a system with
modular programs via STEP 7
• Compact SIMATIC Micro Memory Card (MMC)
Note:
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
6ES7154-8FB01-0AB0 6ES7154-8FX00-0AB0
IM 154-8 F PN/DP CPU IM 154-8 F PN/DP CPU
Work memory 512 Kbyte Work memory 1.5 MByte
General information
Engineering with
• Programming package STEP 7 V 5.5 or higher, As of STEP7 V5.5 with HSP 222 +
Distributed Safety V 5.4 SP4 Distributed Safety V5.4 SP4
Supply voltage
24 V DC Yes Yes
Power losses
Power loss, typ. 8.5 W 8.5 W
Memory
Work memory
• integrated 512 kbyte 1 536 kbyte
Load memory
• pluggable (MMC), max. 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs
for word operations, typ. 0.09 µs 0.03 µs
for fixed point arithmetic, typ. 0.12 µs 0.04 µs
for floating point arithmetic, typ. 0.45 µs 0.16 µs
Counters, timers
and their retentivity
S7 counter
• Number 256 256
IEC counter
• present Yes Yes
S7 times
• Number 256 256
IEC timer
• present Yes Yes
Data areas and their retentivity
Flag
• Number, max. 2 048 byte 2 048 byte
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 F PN/DP CPU
2
Address area
I/O address area
• Inputs 2 048 byte 2 048 byte
• Outputs 2 048 byte 2 048 byte
Process image
• Inputs, adjustable 2 048 byte 2 048 byte
• Outputs, adjustable 2 048 byte 2 048 byte
Time of day
Clock
• Hardware clock (real-time clock) Yes Yes
Operating hours counter
• Number 1 1
1st interface
Interface type Integrated RS 485 interface Integrated RS 485 interface
Physics RS 485/connection: 2 x M12 b-coded RS 485/connection: 2 x M12 b-coded
Functionality
• MPI Yes Yes
• DP master Yes Yes
• DP slave Yes Yes
• Point-to-point connection No No
DP master
• Number of DP slaves, max. 124 124
2nd interface
Interface type PROFINET PROFINET
Physics Ethernet (2 x M12 d-coded; 1 x RJ45) Ethernet (2 x M12 d-coded; 1 x RJ45)
Number of ports 3 3
Functionality
• MPI No No
• DP master No No
• DP slave No No
• PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality Yes; Also simultaneously with IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously with IO Controller functionality Yes; Also simultaneously with IO Controller functionality
• PROFINET CBA Yes Yes
PROFINET IO Controller
• Max. number 128 128
of connectable IO devices for RT
• Number of IO devices with IRT 128 128
and the option "high flexibility"
• Number of IO Devices with IRT 64 64
and the option "high performance",
max.
Isochronous mode
Isochronous operation (application Yes; Yes;
synchronized up to terminal) Via PROFIBUS DP or PROFINET interface Via PROFIBUS DP or PROFINET interface
Communication functions
PG/OP communication Yes Yes
Global data communication
• supported Yes Yes
S7 basic communication
• supported Yes Yes
S7 communication
• supported Yes Yes
Open IE communication
• TCP/IP Yes; Yes;
via integrated PROFINET interface and loadable FBs via integrated PROFINET interface and loadable FBs
- Number of connections, max. 8 8
• ISO-on-TCP (RFC1006) Yes Yes
- Number of connections, max. 8 8
• UDP Yes Yes
- Number of connections, max. 8 8
Web server
• supported Yes Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 F PN/DP CPU
2
Configuration
programming
• Programming language
- LAD Yes Yes
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- CFC Yes Yes
- GRAPH Yes Yes
- HiGraph® Yes Yes
Know-how protection
• User program protection/password Yes Yes
protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 135 mm 135 mm
Height 130 mm 130 mm
Depth 65 mm; 65 mm;
60 mm without cover for RJ45 socket; 60 mm without cover for RJ45 socket;
65 mm with cover for RJ45 socket 65 mm with cover for RJ45 socket
Weights
Weight, approx. 720 g 720 g
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 F PN/DP CPU
2
• Preassembled IE FC TP
MMC 128 Kbyte 1) 6ES7953-8LG30-0AA0 Trailing Cable GP 2 x 2
(PROFINET Type C) with two
MMC 512 Kbyte 1) 6ES7953-8LJ30-0AA0 4-pin M12 plugs (4-pin, D-coded),
MMC 4 Mbyte 1) 6ES7953-8LM31-0AA0 degree of protection IP65/IP67,
in various lengths:
MMC 8 Mbyte 1) 6ES7953-8LP31-0AA0 • 0.3 m 6XV1870-8AE30
MMC for program backup and/or firmware updates • 0.5 m 6XV1870-8AE50
• 1.0 m 6XV1870-8AH10
MMC 2 Mbyte 1) 6ES7953-8LL31-0AA0
• 1.5 m 6XV1870-8AH15
Connection module 6ES7194-4AN00-0AA0 • 2.0 m 6XV1870-8AH20
for CPU IM154-8 PN/DP, • 3.0 m 6XV1870-8AH30
with 4 x M12 and 2 x 7/8", • 5.0 m 6XV1870-8AH50
for connecting PROFINET and • 10 m 6XV1870-8AN10
PROFIBUS DP.
• 15 m 6XV1870-8AN15
SCALANCE X-200 • PROFINET M12 connecting cable,
Industrial Ethernet Switches trailing cable preassembled at
with integral SNMP access, 6GK5208-0HA00-2AA6 both ends with angled M12 con-
Web diagnostics, copper cable nectors (male contact insert),
diagnostics and PROFINET in various lengths:
diagnostics, for setting up linear, • 3.0 m 3RK1902-2NB30
star and ring structures • 5.0 m 3RK1902-2NB50
SCALANCE X208PRO, • 10 m 3RK1902-2NC10
in degree of protection IP65,
• PROFINET M12 connecting cable,
with eight 10/100 Mbit/s M12 ports,
trailing cable preassembled at
incl. eleven M12 dust caps.
one end with angled M12 connec-
Industrial Ethernet FC RJ45 tor (male contact insert at one
Plug 90 end, other end open),
in various lengths:
RJ45 plug-in connector for • 3.0 m 3RK1902-2HB30
Industrial Ethernet with a rugged
metal housing and integrated • 5.0 m 3RK1902-2HB50
insulation displacement contacts • 10 m 3RK1902-2HC10
for connecting Industrial Ethernet
IE FC M12 Plug PRO
FC installation cables;
with 90° cable outlet. PROFINET M12 plug connector,
• 1 unit 6GK1901-1BB20-2AA0 D-coded with fast connection
• 10 units 6GK1901-1BB20-2AB0 system, axial cable outlet
• 1 unit 6GK1901-0DB20-6AA0
Industrial Ethernet FC RJ45
• 8 units 6GK1901-0DB20-6AA8
Plug 180
• PROFINET M12 plug connector, 3RK1902-2DA00
RJ45 plug connector for D-coded, angled
Industrial Ethernet with a rugged
metal enclosure and integrated IE panel feedthrough
insulation displacement contacts Cabinet feedthrough for converting 6GK1901-0DM20-2AA5
for connecting Industrial Ethernet from the M12 connection system
FC installation cables; (D-coded, IP65/IP67) to the RJ45
with 180° cable outlet connection system (IP20),
• 1 unit 6GK1901-1BB10-2AA0 1 pack = 5 units
• 10 units 6GK1901-1BB10-2AB0
• 50 units 6GK1901-1BB10-2AE0
Industrial Ethernet FastConnect
installation cables
• FastConnect Standard Cable 6XV1840-2AH10
• FastConnect Trailing Cable 6XV1840-3AH10
• FastConnect Marine Cable 6XV1840-4AH10
Industrial Ethernet
FastConnect installation cables
• IE FC TP Trailing Cable GP 2 x 2 6XV1870-2D
Sold by the meter,
max. delivery unit 1 000 m
Minimum order quantity 20 m.
• IE TP Torsion Cable GP 2 x 2 6XV1870-2F
Sold by the meter,
max. delivery unit 1 000 m
Minimum order quantity 20 m.
Industrial Ethernet FastConnect
Stripping Tool 6GK1901-1GA00
PROFINET/Industrial Ethernet
SIMATIC ET 200pro
Interface modules
IM 154-8 F PN/DP CPU
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
■ Overview
• Compact block I/O for processing digital, analog and IO-Link
signals for connecting to the PROFINET bus system
• Cabinet-free design with degree of protection IP65/66/67 with
2
M12 connections
• Very rugged and resistant metal enclosure and encapsulated
• Compact module in two types of enclosures:
- 30 mm x 200 mm x 37 mm (W x H x D, long and narrow
enclosure), with 4 x M12 for digital signals
- 60 mm x 175 mm x 37 mm (W x H x D, short and wide
enclosure), with 8 x M12 for digital signals and IO-Link
- 60 mm x 175 mm x 37 mm (W x H x D, short and wide
enclosure) with 4 x M12 or 8 x M12 for analog signals
• PROFINET connection: 2 x M12 and automatic PROFINET
address assignment
• Data transmission rate 100 Mbit/s
• LLDP proximity detection without PG and Fast Startup
(boot up within approx 0.5 seconds)
• Supply and load voltage connection: 2 x M12
• Module variance:
- 8 DI
- 16 DI
- 8 DO (2 A)
- 8 DO (1.3 A)
- 8 DO (0.5 A)
- 16 DO (1.3 A)
- 8 DI/DO (1.3 A),
- 8 AI (U, I, TC, RTD)
- 8 AI (TC, RTD)
- 4 AO (U, I)
- 4 IO-Link + 8 DI + 4 DO (1.3 A)
• Channel-specific diagnostics
• Ambient temperature range -40 °C to 60 °C
■ Technical specifications
6ES7141-6BF00-0AB0 6ES7141-6BG00-0AB0 6ES7141-6BH00-0AB0
Digital input modules 8 DE 24 V DC; 4 x M12 8 DE 24 V DC; 8 x M12 8 DE DC 24 V DC; 8 x M12
General information
Vendor identification (VendorID) 002AH 002AH 002AH
Device identifier (DeviceID) 0306H 0306H 0306H
Supply voltage
24 V DC Yes Yes Yes
permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes
Input current
Current consumption, typ. 100 mA 100 mA 100 mA
Encoder supply
Number of outputs 4 8 8
Output current
• Output current, rated value 100 mA; per output 100 mA; per output 100 mA; per output
24 V encoder supply
• short-circuit protection Yes Yes Yes
Power losses
Power loss, typ. 5.5 W 4.5 W 6.5 W
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Number of digital inputs 8 8 16
• In groups of 2 1 2
Input characteristic curve Yes Yes Yes
in accordance with IEC 61131, type 3
Number of simultaneously
controllable inputs
• all mounting positions
- up to 60 °C, max. 8 8 16
Input voltage
• Type of input voltage DC DC DC
• Rated value, DC 24 V 24 V 24 V
• for signal "0" -3 to +5 V -3 to +5 V -3 to +5 V
• for signal "1" 11 to 30 V 11 to 30 V 11 to 30 V
Input current
• for signal "0", max. 1.5 mA 1.5 mA 1.5 mA
(permissible quiescent current)
• for signal "1", typ. 7 mA 7 mA 7 mA
Input delay
(for rated value of input voltage)
• for standard inputs
- at "0" to "1", max. typically 3 ms typically 3 ms typically 3 ms
- at "1" to "0", max. typically 3 ms typically 3 ms typically 3 ms
Cable length
• Cable length unshielded, max. 30 m 30 m 30 m
Interfaces
Transmission procedure 100BASE-TX 100BASE-TX 100BASE-TX
Transmission rate, max. 100 Mbit/s 100 Mbit/s 100 Mbit/s
Supports protocol for PROFINET IO
• Number of PROFINET interfaces 1 1 1
• Autocrossing Yes Yes Yes
• Automatic detection Yes Yes Yes
of transmission speed
• Integrated switch Yes Yes Yes
• PROFINET IO Device
- IRT with the option "high flexibility" Yes Yes Yes
supported
- Prioritized startup Yes Yes Yes
Protocols
Supports protocol for PROFINET IO Yes Yes Yes
PROFINET CBA No No No
Supports protocol for PROFIsafe No No No
Protocols (Ethernet)
• SNMP Yes Yes Yes
• DCP Yes Yes Yes
• LLDP Yes Yes Yes
• ping Yes Yes Yes
• ARP Yes Yes Yes
Interrupts/diagnostics/
status information
Status indicator Yes; Green LED Yes; Green LED Yes; Green LED
Alarms
• Diagnostic alarm Yes Yes Yes
Diagnostic messages
• Diagnostic functions Yes Yes Yes
• Diagnostic information readable Yes Yes Yes
• Monitoring the supply voltage Yes; Green "ON" LED Yes; Green "ON" LED Yes; Green "ON" LED
• Wire break in signal transmitter Yes Yes Yes
cable
• Short circuit encoder supply Yes; Per channel group Yes; Per channel group Yes; Per channel group
• Group error Yes; Red/yellow "SF/MT" LED Yes; Red/yellow "SF/MT" LED Yes; Red/yellow "SF/MT" LED
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
between the load voltages Yes Yes Yes
between load voltage and all other No No No
switching components
between Ethernet and electronics Yes Yes Yes
Galvanic isolation digital inputs
• between the channels No No No
Permissible potential difference
between different circuits 75 V DC / 60 VAC 75 V DC / 60 VAC 75 V DC / 60 VAC
Isolation
tested with
• 24 V DC circuits 500 V 500 V 500 V
• Interface 1 500 V; 1 500 V; 1 500 V;
According to IEEE 802.3 According to IEEE 802.3 According to IEEE 802.3
Degree and class of protection
IP65 Yes Yes Yes
IP66 Yes Yes Yes
IP67 Yes Yes Yes
Connection method
M12 Yes Yes Yes
Dimensions
Width 30 mm 60 mm 60 mm
Height 200 mm 175 mm 175 mm
Depth 49 mm 49 mm 49 mm
Weights
Weight (without packaging) 550 g 910 g 910 g
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Digital outputs
Number of digital outputs 8 8 8 8 16
• In groups of 8 4 4 4 8
Short-circuit protection Yes Yes Yes Yes Yes
• Response threshold, typ. 0,7 A 1,8 A 1,8 A 2,8 A 1,8 A
Limitation of inductive shutdown Typ. (L1+, L2+) -47 V Typ. (L1+, L2+) -47 V Typ. (L1+, L2+) -47 V Typ. (L1+, L2+) -47 V Typ. (L1+, L2+) -47 V
voltage to
Controlling a digital input Yes Yes Yes Yes Yes
Switching capacity of the outputs
• on lamp load, max. 5W 5W 5W 10 W 5W
Output current
• for signal "1" rated value 0.5 A 1.3 A; Maximum 1.3 A; Maximum 2A 1.3 A; Maximum
• for signal "0" residual current, max. 1.5 mA 1.5 mA 1.5 mA 1.5 mA 1.5 mA
Parallel switching of 2 outputs
• for increased power No No No No No
• for redundant control of a load Yes Yes Yes Yes Yes
Switching frequency
• with resistive load, max. 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz
• on lamp load, max. 1 Hz 1 Hz 1 Hz 1 Hz 1 Hz
Aggregate current of outputs (per
group)
• all mounting positions
- up to 55 °C, max. 3.9 A
- up to 60 °C, max. 4A 2.6 A 3.9 A 3.9 A 3.9 A
Cable length
• Cable length unshielded, max. 30 m 30 m 30 m 30 m 30 m
Interfaces
Transmission procedure 100BASE-TX 100BASE-TX 100BASE-TX 100BASE-TX 100BASE-TX
Transmission rate, max. 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
Supports protocol for PROFINET IO
• Number of PROFINET interfaces 1 1 1 1 1
• Autocrossing Yes Yes Yes Yes Yes
• Automatic detection Yes Yes Yes Yes Yes
of transmission speed
• Integrated switch Yes Yes Yes Yes Yes
• PROFINET IO Device
- IRT with the option "high flexibility" Yes Yes Yes Yes Yes
supported
- Prioritized startup Yes Yes Yes Yes Yes
Protocols
Supports protocol for PROFINET IO Yes Yes Yes Yes Yes
PROFINET CBA No No No No No
Supports protocol for PROFIsafe No No No No No
Protocols (Ethernet)
• SNMP Yes Yes Yes Yes Yes
• DCP Yes Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes Yes
• ping Yes Yes Yes Yes Yes
• ARP Yes Yes Yes Yes Yes
Interrupts/diagnostics/
status information
Status indicator Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED
Alarms
• Diagnostic alarm Yes Yes Yes Yes Yes
Diagnostic messages
• Diagnostic functions Yes Yes Yes Yes Yes
• Diagnostic information readable Yes Yes Yes Yes Yes
• Monitoring the supply voltage Yes; Green "ON" LED Yes; Green "ON" LED Yes; Green "ON" LED Yes; Green "ON" LED Yes; Green "ON" LED
• Wire break in actuator cable Yes Yes Yes Yes Yes
• Short circuit Yes Yes Yes Yes Yes
• Group error Yes; Red/yellow "SF/ Yes; Red/yellow "SF/ Yes; Red/yellow "SF/ Yes; Red/yellow "SF/ Yes; Red/yellow "SF/
MT" LED MT" LED MT" LED MT" LED MT" LED
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Galvanic isolation
between the load voltages Yes Yes Yes Yes Yes
between load voltage and all other No No No No No
switching components
between Ethernet and electronics Yes Yes Yes Yes Yes
Galvanic isolation digital outputs
• between the channels No No No No No
Permissible potential difference
between different circuits 75 V DC / 60 V AC 75 V DC / 60 V AC 75 V DC / 60 V AC 75 V DC / 60 V AC 75 V DC / 60 V AC
Isolation
tested with
• 24 V DC circuits 500 V 500 V 500 V 500 V 500 V
• Interface 1 500 V; 1 500 V; 1 500 V; 1 500 V; 1 500 V;
According to According to According to According to According to
IEEE 802.3 IEEE 802.3 IEEE 802.3 IEEE 802.3 IEEE 802.3
Degree and class of protection
IP65 Yes Yes Yes Yes Yes
IP66 Yes Yes Yes Yes Yes
IP67 Yes Yes Yes Yes Yes
Connection method
M12 Yes Yes Yes Yes Yes
Dimensions
Width 30 mm 30 mm 60 mm 60 mm 60 mm
Height 200 mm 200 mm 175 mm 175 mm 175 mm
Depth 49 mm 49 mm 49 mm 49 mm 49 mm
Weights
Weight (without packaging) 550 g 550 g 910 g 910 g 910 g
6ES7147-6BG00-0AB0 6ES7147-6BG00-0AB0
Digital input/output modules 8 DE/DA 24 V DC/1.3 A; Digital input/output modules 8 DE/DA 24 V DC/1.3 A;
8 x M12 8 x M12
General information Digital inputs
Vendor identification (VendorID) 002AH Number of digital inputs 8
Device identifier (DeviceID) 0306H • In groups of 4
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Digital outputs Interrupts/diagnostics/
Number of digital outputs 8 status information
• In groups of 4 Status indicator Yes; Green LED
Short-circuit protection Yes; Electronic Alarms
• Response threshold, typ. 1.8 A • Diagnostic alarm Yes
Limitation of inductive shutdown Typ. (L1+, L2+) -47 V Diagnostic messages
voltage to • Diagnostic functions Yes
Controlling a digital input Yes • Diagnostic information readable Yes
• Monitoring the supply voltage Yes; Green "ON" LED
Switching capacity of the outputs • Wire break in actuator cable Yes
• on lamp load, max. 5W • Wire break in signal transmitter Yes
Output current cable
• for signal "1" rated value 1.3 A; Maximum • Short circuit Yes
• for signal "0" residual current, max. 1.5 mA • Short circuit encoder supply Yes
• Group error Yes;
Parallel switching of 2 outputs Red/yellow "SF/MT" LED
• for increased power No
• for redundant control of a load Yes Galvanic isolation
between the load voltages Yes
Switching frequency
• with resistive load, max. 100 Hz between load voltage and all other No
switching components
• with inductive load, max. 0.5 Hz
• on lamp load, max. 1 Hz between Ethernet and electronics Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Vendor identification (VendorID) 002AH 002AH
Device identifier (DeviceID) 0306H 0306H
Supply voltage
24 V DC Yes Yes
permissible range, lower limit (DC) 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V
Reverse polarity protection Yes Yes; against destruction
Input current
Current consumption, typ. 110 mA 110 mA
Encoder supply
Number of outputs 4
24 V encoder supply
• short-circuit protection Yes; Electronic at 1.4 A
• Output current, max. 1A
Power losses
Power loss, typ. 2.8 W 2.8 W
Analog inputs
Number of analog inputs 8 8
Number of analog inputs for 4
voltage/current measurement
Number of analog inputs for 4 8
resistance/resistance thermometer
measurement
permissible input voltage for 28.8 V permanent,
voltage input (destruction limit), max. 35 V for max. 500 ms
Input ranges (rated values),
voltages
• 0 to +10 V Yes
• 1 to 5 V Yes
• -10 V to +10 V Yes
• -80 mV to +80 mV Yes Yes
Input ranges (rated values),
currents
• 0 to 20 mA Yes
• -20 to +20 mA Yes
• 4 to 20 mA Yes
Input ranges (rated values),
thermoelements
• Type E Yes Yes
• Type J Yes Yes
• Type K Yes Yes
• Type N Yes Yes
Input ranges (rated values),
resistance thermometers
• Ni 100 Yes Yes
• Ni 1000 Yes Yes
• Ni 120 Yes Yes
• Ni 200 Yes Yes
• Ni 500 Yes Yes
• Pt 100 Yes Yes
• Pt 1000 Yes Yes
• Pt 200 Yes Yes
• Pt 500 Yes Yes
Input ranges (rated values),
resistors
• 0 to 150 ohms Yes Yes
• 0 to 300 ohms Yes Yes
• 0 to 600 ohms Yes Yes
• 0 to 3000 ohms Yes Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
• Temperature compensation
- Parameterizable Yes Yes
- internal temperature Yes Yes
compensation
- external temperature Yes Yes
compensation with
compensations socket
- external temperature Yes
compensation with Pt100
- dynamic reference Yes
temperature value
- for definable comparison point Yes
temperature
Cable length
• Cable length, shielded, max. 30 m 30 m
Analog value creation
Analog value display SIMATIC S7 format SIMATIC S7 format
Measurement principle integrating integrating
Integrations and conversion
time/resolution per channel
• Resolution (incl. overrange) 15 bits + sign 15 bits + sign
• Integration time, parameterizable Yes Yes
• Integration time, ms 2/16.67/20/100 ms 2/16.67/20/100 ms
• Interference voltage suppression 500 / 60 / 50 / 10 Hz 500 / 60 / 50 / 10 Hz
for interference frequency f1 in Hz
• Conversion time (per channel) 4 / 19 / 22 / 102 ms 4 / 19 / 22 / 102 ms
Smoothing of measured values
• Parameterizable Yes Yes
• Step: None Yes; 1 x cycle time Yes; 1 x cycle time
• Step: low Yes; 4 x cycle time Yes; 4 x cycle time
• Step: Medium Yes; 16 x cycle time Yes; 16 x cycle time
• Step: High Yes; 64 x cycle time Yes; 64 x cycle time
Encoder
Number of connectable encoders, 8 8
max.
Connection of signal encoders
• for voltage measurement Yes
• for current measurement Yes
as 2-wire transducer
• for current measurement Yes
as 4-wire transducer
• for resistance measurement Yes Yes
with two-wire connection
• for resistance measurement Yes Yes
with three-wire connection
• for resistance measurement Yes Yes
with four-wire connection
Errors/accuracies
Linearity error 0.01 % 0.01 %
(relative to input range), (+/-)
Temperature error U: 0.0035%/°C; I: 0.006%/°C; RTD: 0.0005%/°C; RTD: 0.0005%/°C; TC: 0.0035%/°C
(relative to input range), (+/-) TC: 0.0035%/°C
Crosstalk between the inputs, min. 85 dB -85 dB
Repeat accuracy in steady state at 0.008 % 0.008 %
25 °C (relative to input area), (+/-)
Interference voltage suppression
for f = n x (f1 +/- 1 %),
f1 = interference frequency
• Series mode interference 46 dB 46 dB
(peak value of interference < rated
value of input range), min.
• Common mode interference, min. 70 dB 70 dB
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Transmission procedure 100BASE-TX 100BASE-TX
Transmission rate, max. 100 Mbit/s 100 Mbit/s
Supports protocol for PROFINET IO
• Number of PROFINET interfaces 1 1
• Autocrossing Yes Yes
• Automatic detection Yes Yes
of transmission speed
• Integrated switch Yes Yes
• PROFINET IO Device
- IRT with the option "high flexibility" Yes
supported
- Prioritized startup Yes Yes
Protocols
Supports protocol for PROFINET IO Yes Yes
PROFINET CBA No No
Supports protocol for PROFIsafe No No
Protocols (Ethernet)
• SNMP Yes Yes
• DCP Yes Yes
• LLDP Yes Yes
• ping Yes Yes
• ARP Yes Yes
Interrupts/diagnostics/
status information
Status indicator Yes
Alarms
• Diagnostic alarm Yes Yes
Diagnostic messages
• Diagnostic functions Yes Yes
• Diagnostic information readable Yes Yes
• Monitoring the supply voltage Yes; Green "ON" LED Yes; Green "ON" LED
• Short circuit encoder supply Yes; per module
• Group error Yes; Red/yellow "SF/MT" LED Yes; Red/yellow "SF/MT" LED
• Overflow/underflow Yes Yes
Galvanic isolation
between the load voltages Yes Yes
between load voltage and all other No No
switching components
between Ethernet and electronics Yes Yes
Galvanic isolation analog inputs
• between the channels No No
Permissible potential difference
between inputs and MANA (UCM) 10 Vpp AC 10 Vpp AC
Isolation
tested with
• 24 V DC circuits 500 V 500 V
• Interface 1 500 V; According to IEEE 802.3 1 500 V; According to IEEE 802.3
Degree and class of protection
IP65 Yes Yes
IP66 Yes Yes
IP67 Yes Yes
Connection method
M12 Yes Yes
Dimensions
Width 60 mm 60 mm
Height 175 mm 175 mm
Depth 49 mm 49 mm
Weights
Weight (without packaging) 930 g 930 g
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
General information Analog value creation
Vendor identification (VendorID) 002AH Analog value display SIMATIC S7 format
Device identifier (DeviceID) 0306H Measurement principle Resistor network
Supply voltage Integrations and conversion time/res-
24 V DC Yes olution per channel
• Resolution (incl. overrange) 15 bits + sign
permissible range, lower limit (DC) 20.4 V
• Conversion time (per channel) 1 ms
permissible range, upper limit (DC) 28.8 V
Settling time
Reverse polarity protection Yes • for resistive load 2 ms
Input current • for capacitive load 1.8 ms
Current consumption, typ. 280 mA • for inductive load 2 ms
Encoder supply Errors/accuracies
Number of outputs 4 Output ripple U: ±0.6 mVrms;
(based on output area, I: ±0.4 nArms
24 V encoder supply bandwidth 0 to 50 kHz), (+/-)
• short-circuit protection Yes; Electronic at 1.4 A
Linearity error 0.02 %
• Output current, max. 1A (relative to output range), (+/-)
Power losses Temperature error U: 0.001%/°C;
Power loss, typ. 5.5 W (relative to output range), (+/-) I: 0.0025%/°C
Analog outputs Crosstalk between the outputs, min. 70 dB
Number of analog outputs 4
Repeat accuracy in steady state at 0.008 %
Voltage output, Yes 25 °C (relative to output area), (+/-)
short-circuit protection
Interfaces
Voltage output, short-circuit current, 30 mA Transmission procedure 100BASE-TX
max.
Transmission rate, max. 100 Mbit/s
Current output, no-load voltage, 20 V
max. Supports protocol for PROFINET IO
• Number of PROFINET interfaces 1
Output ranges, voltage
• Autocrossing Yes
• 0 to 10 V Yes
• Automatic detection Yes
• 1 to 5 V Yes of transmission speed
• -10 to +10 V Yes • Integrated switch Yes
Output ranges, current • PROFINET IO Device
• 0 to 20 mA Yes - IRT with the option "high flexibility" Yes
• -20 to +20 mA Yes supported
• 4 to 20 mA Yes - Prioritized startup Yes
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Interrupts/diagnostics/ Input current
status information from load voltage 1L+ 4A
Status indicator Yes (unswitched voltage)
Substitute values connectable Yes from load voltage 2L+, max. 4A
Alarms Encoder supply
• Diagnostic alarm Yes Number of outputs 6
Diagnostic messages Output current
• Diagnostic functions Yes • Output current, rated value 200 mA;
• Diagnostic information readable Yes 100 mA per output to X5-X6
• Monitoring the supply voltage Yes; Green "ON" LED 24 V encoder supply
• Wire break Yes; Channel-by-channel • short-circuit protection Yes
with current output
• Short circuit Yes; Channel-by-channel Power losses
with voltage output Power loss, typ. 8W
• Group error Yes; Red/yellow "SF/MT" LED Digital inputs
Galvanic isolation Number of digital inputs 8
between the load voltages Yes Input characteristic curve in Yes
between load voltage and all other No accordance with IEC 61131, type 3
switching components Number of simultaneously
between Ethernet and electronics Yes controllable inputs
• all mounting positions
Galvanic isolation analog outputs - up to 60 °C, max. 8
• between the channels No
Input voltage
Permissible potential difference • Rated value, DC 24 V
between M internally and the outputs 10 Vpp AC • for signal "0" -3 to +5 V
Degree and class of protection • for signal "1" 11 to 30 V
IP65 Yes Input current
IP66 Yes • for signal "0", max. 1.5 mA
(permissible quiescent current)
IP67 Yes
• for signal "1", typ. 7 mA
Connection method
Input delay
M12 Yes (for rated value of input voltage)
Dimensions • for standard inputs
Width 60 mm - at "0" to "1", max. typically 3 ms
Height 175 mm - at "1" to "0", max. typically 3 ms
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
2
Interfaces Galvanic isolation
Transmission procedure 100BASE-TX between the load voltages Yes
Transmission rate, max. 100 Mbit/s between load voltage and all other No
switching components
Supports protocol for PROFINET IO
• Number of PROFINET interfaces 1 between Ethernet and electronics Yes
• Autocrossing Yes Galvanic isolation digital inputs
• Automatic detection Yes • between the channels No
of transmission speed
• Integrated switch Yes Galvanic isolation digital outputs
• PROFINET IO Device • between the channels No
- IRT with the option "high flexibility" Yes Permissible potential difference
supported between different circuits 75 V DC / 60 V AC
- Prioritized startup Yes
Isolation
Protocols tested with
Supports protocol for PROFINET IO Yes • 24 V DC circuits 500 V
PROFINET CBA No • Interface 1 500 V; According to IEEE 802.3
Supports protocol for PROFIsafe No Degree and class of protection
IP65 Yes
Protocols (Ethernet)
• SNMP Yes IP66 Yes
• DCP Yes IP67 Yes
• LLDP Yes
Connection method
• ping Yes
M12 Yes
• ARP Yes
Dimensions
IO-Link
Width 60 mm
Number of ports 4
• of which simultaneously 4 Height 175 mm
controllable Depth 49 mm
Transmission rate 4.8 kBd (COM1); Weights
38.4 kBd (COM2)
Weight (without packaging) 910 g
Cable length unshielded, max. 20 m
Operating modes
• IO-Link Yes
• DI Yes
• DQ Yes
Connection of IO-Link devices
• via three-wire connection Yes
Interrupts/diagnostics/
status information
Status indicator Yes; Green LED
Alarms
• Diagnostic alarm Yes
Diagnostic messages
• Diagnostic functions Yes
• Diagnostic information readable Yes
• Monitoring the supply voltage Yes; Green "ON" LED
• Wire break in actuator cable Yes
• Wire break in signal transmitter ca- Yes
ble
• Short circuit Yes
• Short circuit encoder supply Yes
• Group error Yes; Red/yellow "SF/MT" LED
PROFINET/Industrial Ethernet
SIMATIC ET 200eco
ET 200eco PN
ET 200eco PN Accessories
digital input module
• PD voltage distributor, 24 V DC; 6ES7148-6CB00-0AA0
• 8 DI 24 V DC; 6ES7141-6BF00-0AB0 1 X 7/8“, 4 X M12
4 x M12, dual assignment,
degree of protection IP67
• 8 DI 24 V DC; 6ES7141-6BG00-0AB0
• Terminal block for ET 200eco PN,
10 A insulation-piercing terminals
• Spare fuses for terminal block,
6ES7194-6CA00-0AA0
6ES7194-6HB00-0AA0
2
8 x M12,
degree of protection IP67 10 units
• 16 DI 24 V DC; 6ES7141-6BH00-0AB0 • Mounting rail 0.5 m 6ES7194-6GA00-0AA0
8 x M12, dual assignment, • Profile screw for mounting rail, 6ES7194-6MA00-0AA0
degree of protection IP67 50 units
• Sealing cap M12 for IP67 modules, 3RX9802-0AA00
ET 200eco PN 10 units
digital output module
• Labels 10 × 7 mm, 3RT1900-1SB10
• 8 DO 24 V DC/0.5 A; 6ES7142-6BF50-0AB0 pastel turquoise,
4 x M12, dual assignment, 816 units
1 load voltage supply DO;
degree of protection IP67 PROFINET M12 connector,
• 8 DO 24 V DC/1.3 A; 6ES7142-6BF00-0AB0 for user assembly
4 x M12, dual assignment,
IE FC M12 connector PRO,
degree of protection IP67
for user assembly
• 8 DO 24 V DC/1.3 A; 6ES7142-6BG00-0AB0 • 1 unit 6GK1901-0DB20-6AA0
8 x M12,
degree of protection IP67 • 8 units 6GK1901-0DB20-6AA8
• 8 DO 24 V DC/2 A; 6ES7142-6BR00-0AB0 PROFINET M12
8 x M12, connecting cables
degree of protection IP67
Preassembled connecting cables
• 16 DO 24 V DC/1.3 A; 6ES7142-6BH00-0AB0
with 2 M12 connectors (D-coded)
8 x M12, dual assignment,
in various lengths:
degree of protection IP67
• 0.3 m 6XV1870-8AE30
ET 200eco PN • 0.5 m 6XV1870-8AE50
digital input/output modules
• 1.0 m 6XV1870-8AH10
• 8 DI/DO 24 V DC/1.3 A; 6ES7147-6BG00-0AB0
• 1.5 m 6XV1870-8AH15
8 x M12,
degree of protection IP67 • 2.0 m 6XV1870-8AH20
• 3.0 m 6XV1870-8AH30
ET 200eco PN
analog input modules • 5.0 m 6XV1870-8AH50
• 8 AI 4 U/I + 4 RTD/TC; 6ES7144-6KD00-0AB0 • 10.0 m 6XV1870-8AN10
8 x M12, • 15.0 m 6XV1870-8AN15
degree of protection IP67 M12 connector for 24 V DC
• 8 AI RTD/TC; 8 x M12, 6ES7144-6KD50-0AB0 load power supply
degree of protection IP67
Connection socket for 24 V DC 6GK1907-0DC10-6AA3
ET 200eco PN incoming supply;
analog output modules 4-pin, A-coded, 3 units
• 4 AO U/I; 6ES7145-6HD00-0AB0
4 x M12, Connector for loop-through 6GK1907-0DB10-6AA3
degree of protection IP67 of 24 V DC;
4-pin, A-coded, 3 units
ET 200eco PN IO-Link
master module M12 plug-in power cables
• 4 IO-L + 8 DI + 6ES7148-6JA00-0AB0 Preassembled plug-in power
4 DO 24 V DC/1.3 A; cables, fitted at each end with
8 x M12, M12 socket and plug 4 x 0.75 mm2,
degree of protection IP67 in various lengths:
• 0.3 m 6XV1801-5DE30
• 0.5 m 6XV1801-5DE50
• 1.0 m 6XV1801-5DH10
• 1.5 m 6XV1801-5DH15
• 2.0 m 6XV1801-5DH20
• 3.0 m 6XV1801-5DH30
• 5.0 m 6XV1801-5DH50
• 10.0 m 6XV1801-5DN10
• 15.0 m 6XV1801-5DN15
M12 coupler plug
Can be assembled, for connecting 3RK1902-4BA00-5AA0
actuators or sensors,
5-pin
Y cable M12
For double connection of I/O 6ES7194-6KA00-0XA0
by means of single cable to ET 200,
5-pin
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
The SIMOTION system
■ Overview
The SIMOTION system is made up of three components:
Engineering system
2
SCOUT enables Motion Control, PLC and technology functions
to be incorporated in one comprehensive, integrated system
and provides all the necessary tools: From programming and
parameterization through testing and commissioning, to diag-
nostics.
Runtime software
The runtime software offers a high-performance execution
system for cyclic and sequential tasks. The runtime software
modules make the different PLC, Motion Control and technology
functions available. By selecting the appropriate modules, the
overall functionality of the system can be flexibly adapted to the
machine.
Hardware platforms
The hardware platforms are the basis of the SIMOTION Motion
Control System. The application created with the engineering
system and the associated runtime software modules can be
implemented on different hardware platforms.
PLC functionality
(IEC 61131-3)
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
SIMOTION Hardware platforms
■ Overview
One concept – 3 platforms SIMOTION C – Modularity and flexibility
Automation systems are primarily identified by the following
characteristics:
• System-specific characteristics, e.g. functionality and
engineering
2
• Hardware-dependent characteristics, e.g. performance,
design and expandability
However, mechanical engineering demands vary greatly, de-
pending on the version of the machine in question.
Every hardware platform has its benefits when used in certain
applications.
The various platforms can also be combined very easily, which
is a particular advantage in modular machines and plants. This
is because the individual hardware platforms always have the
same system characteristics, i.e. functionality and engineering
are always identical, irrespective of the platform used.
PROFIBUS or PROFINET can be used to create the link to the
drives and the I/Os remotely.
PROFINET/PROFIBUS can also be used for communication with SIMOTION C is a Motion Controller based on the
HMI devices such as SIMATIC HMI or higher-level controllers SIMATIC S7-300 design.
such as SIMATIC S7. This means that SIMATIC HMI panels It is available in two variants which differ in terms of their
as well as PCs with WinCC flexible can be used as operator interfaces, but not with respect to Motion Control functionality or
systems. Even 3rd party applications communicate with performance. In addition to the already integrated interfaces,
SIMOTION by means of the OPC interface. both controllers can be expanded using I/O modules from the
SIMATIC S7-300 range.
SIMOTION D – Compact and integrated in the drive
Variant C240 with its four drive and encoder interfaces is ideal
for machine automation applications and the operation of drives
with analog setpoint interface or stepper drives. As a result, this
variant is particularly suitable for machine retrofits.
Variant C240 PN with its three PROFINET ports, which support
PROFINET with IRT as well as TCP/IP and RT communication,
is used to automate machines on the basis of PROFINET. It is
capable of operating PROFINET drives with PROFIdrive, as well
as PROFINET I/Os, such as SIMATIC ET 200S High Speed.
Both variants are equipped additionally with two PROFIBUS
interfaces via which drives with PROFIdrive profile as well as
standard I/Os can be connected. In addition, both controllers
feature an Industrial Ethernet interface, thus offering further
communication options.
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
SIMOTION Hardware platforms
■ Overview (continued)
SIMOTION P – Open for multiple tasks
SIMOTION P320-3 has been created for Embedded PC Motion
Control applications. Thanks to the Embedded Windows
2
operating system and elimination of rotating parts in the PC, the
SIMOTION P320-3 is particularly compact and ideal for applica-
tions in harsh environments. Both PCs are equipped with the
usual real-time expansion for SIMOTION. This means that in
addition to SIMOTION machine applications, it is possible to run
other PC applications at any time including, for example, the
SIMOTION engineering system, an operator application, a
process data evaluation routine or standard PC applications.
With its excellent processor performance, SIMOTION P350-3
is predestined for applications with exacting performance re-
quirements (such as hydraulic applications with highly dynamic
position and pressure control loops). SIMOTION P320-3 is
particularly suitable for harsh operating environments. Its small
footprint makes it the preferred choice for many applications in
which available space and rugged design play a key role.
The SIMOTION P350-3 can be operated by a variety of different
SIMOTION panel fronts. These are available in various screen
SIMOTION P is a PC-based Motion Control System. sizes and can either be operated using a keyboard and mouse,
The capabilities of the portfolio of PC-based controllers with or a touch screen. The SIMOTION P320-3 can be linked to the
SIMOTION P320-3, the embedded PC for Motion Control, and SIMOTION fronts by means of the Remote Panel PC Kit. For both
SIMOTION P350-3 with the operating system Windows XP PC variants, the SIMATIC flat panel series offers further scope for
Professional are well-demonstrated in practice – and not just for solutions in which the PC is not directly connected to the front
high-end tasks. panel.
SIMOTION P350-3 is available in either a PROFINET or
PROFIBUS variant for the connection of I/Os, while
SIMOTION P320-3 is available only as a PROFINET variant.
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
Motion Control architectures with SIMOTION
■ Overview
Motion Control architectures with SIMOTION and SINAMICS
Switch/Firewall
With SIMOTION and SINAMICS, a range of different automation
PROFINET
structures can be implemented over PROFINET. In this case,
central architectures comprising a controller (e.g. SIMOTION P)
are supported as well as decentralized, distributed architectures SINAMICS S120 SINAMICS S120
SINAMICS
CU310-2 PN 2
with several distributed controllers (e.g. SIMOTION D with with Power Module
SINAMICS S120).
When SIMOTION is integrated in a complete automation system,
hierarchic automation structures often result.
Thanks to the ability to configure SIMOTION as controller and SIMOTION P
device concurrently on the same PROFINET interface (I-Device),
both hierarchic automation structures and modular machine
G_PM10_EN_00136c
concepts can be implemented easily and without additional
components:
• On the one hand, SIMOTION as a device can communicate
with a higher-level controller, e.g. a SIMATIC S7 PLC or a
non-Siemens PLC.
• On the other hand, SIMOTION can also communicate with
local IO devices, such as drives and I/O modules, in the role
of IO Controller.
Via controller-to-controller and controller-to-device relationships
based on PROFINET IO with IRT, it is also possible to synchro-
nize large axis quantity structures via several SIMOTION IO Central Motion Control architecture
Controllers. This functionality is known as distributed synchro-
nous operation.
Switch/Firewall
PROFINET
HMI
G_PM10_EN_00137b
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
PROFINET for SIMOTION
■ Overview
PROFINET – Functions of SIMOTION motion controllers
SIMOTION device C240 PN D410-2 D425-2 D435-2 D445-2 D455-2 P350-3 P320-3
DP/PN DP/PN DP/PN DP/PN DP/PN
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
PROFIdrive for SIMOTION
■ Overview
PROFIdrive – The standardized drive interface Is PROFIdrive future-proof?
for PROFINET and PROFIBUS
PROFIdrive has been specified by PROFIBUS and PROFINET
PROFIdrive defines the device behavior and the access proce- International (PI) and has been laid down in IEC 61800-7 as a
dure to internal drive data for electrical drives on PROFINET and
PROFIBUS, from simple frequency converters up to high-
future-proof standard.
The basic philosophy: Keep it simple
2
performance servo controllers.
It contains a detailed description of how the communication The PROFIdrive profile tries to keep the drive interface as simple
functions "slave-to-slave communication", "constant bus cycle as possible and free from technology functions. This philosophy
time" and "isochronous operation" are used for drive applica- ensures that reference models as well as the functionality and
tions. In addition, it clearly specifies all device characteristics performance of the PROFINET/PROFIBUS master have no or
which influence interfaces connected to a controller over very little influence on the drive interface.
PROFINET or PROFIBUS. This includes the sequence control, One drive profile – Different application categories
encoder interface, standardization of values, definition of
standard messages, and access to drive parameters, etc. The integration of drives into automation solutions depends
strongly upon the drive task. To cover the extensive range of
The PROFIdrive profile supports both central as well as drive applications from the simple frequency converter up to
distributed motion control concepts. highly dynamic, synchronized multi-axis systems with a single
What are profiles? profile, PROFIdrive defines six application categories which
define most drive applications:
Profiles specify specific properties and responses for devices • Category 1 – Standard drives (such as pumps, fans, stirring
and systems in automation. In this manner, manufacturers and units, etc.)
users pursue the goal of defining common standards. Devices
and systems that comply with a multi-vendor profile can inter- • Category 2 – Standard drives with technology functions
operate on a fieldbus and can be operated interchangeably to a • Category 3 – Positioning drives
certain extent. • Category 4 – Motion control drives with central, higher-level
Do different profile types exist? motion control intelligence and the patented "Dynamic Servo
Control" position control concept
A distinction is made between application profiles (general or
specific) and system profiles: • Category 5 – Motion control drives with central, higher-level
motion control intelligence and position setpoint interface
• Application profiles (also known as device profiles) mainly
refer to devices (e.g. drives) and contain an agreed selection • Category 6 – Motion control drives with distributed motion
of bus communication modes, as well as specific device control intelligence integrated in the drives
applications.
• System profiles describe system classes and include the
master functionality, program interfaces and integration
methods.
PROFINET/Industrial Ethernet
Motion Control System SIMOTION
PROFIdrive for SIMOTION
Application Class 4
Automation
Technology
Interpolation
Pos. Control
Clock G_PM10_EN_00133
Control Word + Speed Setpoint + ... Status Word + Actual Position ...
Clock synchronism
M Encoder
M Encoder
M Encoder
PROFINET/Industrial Ethernet
SINUMERIK CNC automation systems
SINUMERIK 828D BASIC T/BASIC M with SINAMICS S120 Combi
PROFINET/Industrial Ethernet
SINUMERIK CNC automation systems
SINUMERIK 840D sl
■ Overview ■ Benefits
• Maximum performance and flexibility for medium to complex
multi-axis systems, thanks to scalable hardware and software
• Consistent openness in the area of the user interface, the PLC,
and the NC core for the integration of your specific know-how
2 • Integrated safety functions for man and machine:
SINUMERIK Safety Integrated
• Comprehensive range of functions for the integration of
machine tools into communication, engineering and
production processes:
SINUMERIK Integrate
■ Application
The SINUMERIK 840D sl can be used globally in the following
technologies:
• Turning
• Drilling
• Milling
SINUMERIK 840D sl offers modularity, openness, flexibility and • Grinding
uniform structures for operation, programming, and visual-
• Laser cutting
ization. It provides a system platform with trend-setting functions
for almost all technologies. • Nibbling
Integrated into the SINAMICS S120 drive system and comple- • Punching
mented by the SIMATIC S7-300 automation system, the • Toolmaking and moldmaking
SINUMERIK 840D sl forms a complete digital system that is • High-speed cutting applications
optimally suited to the mid and upper performance range.
• Woodworking and glass processing
SINUMERIK 840D sl is characterized by: • Handling
• A high level of flexibility • Transfer lines
• Maximum dynamics and precision • Rotary indexing machines
• Optimum integration into networks • Mass series production
• JobShop production
For use in countries requiring approval, there is the export
version SINUMERIK 840DE sl.
■ More information
• Catalog NC 62
• Interactive Catalog CA 01
• Internet:
www.siemens.com/sinumerik
www.siemens.com/industrymall
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Key Panels
SIMATIC HMI KP8/KP8F/KP32F
• More than 30% savings in material costs compared to conven- Empty front design 6AV3688-3XY38-3AX0
tional keypad operator panels for standard 22.5 mm
operator controls, same mounting
• 2 PROFINET ports (incl. switch) already integrated for setting dimensions as KP8
up line and ring topologies
Demo case A5E314777880
• Freely configurable digital I/Os on the rear for connecting
(Only by fax to
key-operated switches, indicator lamps, etc. +49 911 750 2411)
• Connection of fail-safe emergency stop buttons or other includes:
fail-safe signals with KP8F and KP32F (in SIL2 or SIL3) 1 x case
1 x KP8 PN1 x CPU 1211C
• Functionally compatible with all standard PROFINET master 1 x stand, permanently wired,
CPUs, also non-Siemens including program;
KP8 and empty front design, also optimized for installation in Power supply possible with a
standard laptop mains adapter
IPC Extension Units in IP65 (not included in scope of supply)
• Maximum flexibility due to parameterization 12-pole connector set for 6AV6671-3XY38-4AX0
• Empty front design for standardized assembly of flexible KP8 PN
operator panels 10 items per packaging unit
SIMATIC HMI Key Panel – Blank front design 16-pole connector set for 6AV6671-3XY48-4AX0
KP8F PN
• Simple seamless installation with mounting clips
10 items per packaging unit
• Rugged design, suitable for harsh industrial environments
16-pole connector set for 6AV6671-3XY58-4AX0
• Prepared for installation of 22.5 mm standard components KP8F PN
Easy installation, or retrofitting during operation, of standard
22.5 mm operator controls 4 items per packaging unit
Documentation
You can find the manual for the http://support.automation.sie-
Key Panels on the Internet at: mens.com/WW/view/en/56652789
Note:
For further information see Catalog ST 80 / ST PC and
Industry Mall at www.siemens.com/industrymall
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Basic Panels
Standard
■ Overview
With their fully developed HMI basic functions, 2nd generation
SIMATIC HMI Basic Panels are the ideal entry level series for
simple HMI applications.
2 The device family offers panels with 4", 7", and 9" displays, as
well as combined key and touch operation.
The innovative high-resolution widescreen displays with
64 000 colors are also suitable for upright installation, and they
can be dimmed down to 100 %.
The innovative operator interface with improved usability
opens up a diverse range of options thanks to new controls and
graphics.
The new USB interface enables the connection of keyboard,
mouse or barcode scanner, and supports the simple archiving of
data on a USB stick.
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Comfort Panels
Standard
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Mobile Panels
■ Overview
SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277
• Two three-stage acknowledgement buttons;
Optional versions include:
2
- STOP button
- STOP button, handwheel, key-operated switch and
illuminated pushbutton (not for Mobile Panel 277 10")
• Communication is supported via a serial link, MPI/PROFIBUS
or PROFINET
• Connection point recognition for local identification of the
device based on the connection point ID
• Fast system availability after plugging into the connection
boxes
• Connection to the controller and power supply is made via the
connection box and the connecting cable
SIMATIC Mobile Panel 277(F) IWLAN
• Wireless, mobile operator panel for flexible and location-
independent system and machine operation
SIMATIC Mobile Panel • WLAN communication in accordance with IEEE 802.11
• Mobile operator panel for direct operator control of the plant (a/b/g/h) and PROFINET support
and machine from any point • Powerful batteries and flexible concept for changing permit
• Supports an optimum view of the workpiece or process and, battery replacement "on the fly" without interrupting operation
at the same time, direct access and visual contact with the • Effective range limitation and the local identification of the
operator panel device by using transponder technology
• Versatile use thanks to easy unplugging and replugging • Low-cost, safety-related mobile operator control and
during normal operation (Mobile Panel 177 and monitoring via RFID technology (MOBY D) for plants with
Mobile Panel 277) or pre-installed safety resources (e.g. robot cells)
• Wireless freedom (Mobile Panel 277(F) IWLAN) • Optional variants with: Handwheel, key switch and illuminated
• Pixel-graphics, high-luminance color display with touch pushbutton
screen (analog/resistive) • Fail-safe operator controls of the SIMATIC Mobile Panel 277F
• PROFIBUS or PROFINET communication, PROFINET over IWLAN using PROFIsafe:
WLAN for Mobile Panel 277(F) IWLAN - Two three-stage acknowledgment buttons
- Emergency stop button
• Freely-configurable function keys with customized labels
(with LED) (not for Mobile Panel 277 10")
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Mobile Panels
PROFINET/Industrial Ethernet
Operating and Monitoring Devices
Mobile Panels
• French 6AV6691-1CA01-3AC0
• Italian 6AV6691-1CA01-3AD0
• Spanish 6AV6691-1CA01-3AE0
Note:
For further information see Catalog ST 80 / ST PC and
Industry Mall at www.siemens.com/industrymall
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
General data
■ Overview
SIMATIC IPC547E –
maximum performance at an attractive price
• Intel Core i processors 4th generation
• Maximum processor performance in maximum configuration
without loss of power (throttling) at ambient temperatures of up 2
to 40 °C
• Optional RAID5 configuration (striping with parity) in hot swap
drive bays
• RAID1 and RAID5 configurations with additional hot spare
hard disk, optional
• Low noise output thanks to controlled fans
• Status and alarm LEDs at the front for signaling critical system
states
• Availability for at least 1.5 years
• Guaranteed spare parts availability for at least 3 years
SIMATIC IPC647D – maximum compactness combined with
IPC rack family maximum industrial functionality
• Maximum compactness due to 4 free PCI/PCI Express slots
Rack PCs are flexible, high-availability industrial PC systems for for installing long expansion cards and integrated interfaces
powerful yet compact applications using 19" technology. for communication, e.g. integrated PROFIBUS/MPI or
Three device classes are available for various requirements: PROFINET interface
• High thermal stability up to 50 °C ambient temperature, even
SIMATIC IPC547 – at maximum processor performance
maximum performance at an attractive price
• High vibration/shock resistance thanks to special hard disk
SIMATIC IPC647 – holders
maximum compactness combined with maximum industrial
functionality • Intel Core i processors 4th generation
• ECC memory, optional
SIMATIC IPC847 –
maximum expandability and industrial functionality • Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
Shared industrial functionality of the IPC series 547, 647 and 847 tools, or opening of the enclosure with just one screw.
• Maximum system performance for complex automation tasks • Front LED concept for efficient self-diagnostics, e.g.
and computationally intensive PC tasks in the industrial monitoring of hard disks in RAID1 configurations, fans or the
environment through use of Intel Core processors status display for Ethernet, PROFINET and PROFIBUS.
• Designed for 24-hour continuous operation • Integrated PROFIBUS DP/MPI or PROFINET interface
• Monitoring and diagnostics functions (e.g. temperature, fan, (optional)
watchdog) • High component/design continuity
• RAID1 configuration (mirrored drives), optionally in hot swap • Motherboard developed and manufactured by Siemens
drive bays • Availability for up to 6 years
• Hard disks with capacities up to 1 TB for large volumes of data • Guaranteed spare parts availability for at least 5 years
• Solid-state drive (SSD) with MLC technology, optional
• Redundant AC power supply, optional
• Compact dimensions for installation in control cabinets only
500 mm deep
• Dust protection thanks to overpressure ventilation concept
with fan on the front and dust filter
• Lockable front panel or front door
• Service-friendly equipment design due to prepared telescopic
rail mounting
• Universal implementation as an industrial workstation or
server
• Operating system preinstalled and activated for fast startup
• Fast restoration of the delivery status of the HDD thanks to
restore DVD
• High flexibility and expandability of components
• PCI and PCI Express expansion slots
• Independent industrial product design
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
General data
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
General data
■ Technical specifications
Rack PC SIMATIC IPC347D SIMATIC IPC547E SIMATIC IPC547E SIMATIC IPC647D SIMATIC IPC847D
Enclosure depth Enclosure depth
356 mm 446 mm
Design
19" rack 4 HU 4U 4U 2 HU 4 HU
2
Prepared for telescopic rails • • • • •
Horizontal/vertical installation •/- •/• •/• •/- •/•
19" mounting bracket can be • • • • •
removed from outside
Tower Kit (optional) - • • - •
General features
Processor • Intel Core i5-3340S • Intel Pentium Dual • Intel Core i7-4770S • Intel Xeon E3-1268L • Intel Xeon E3-1268L
(4C/4T, 2.8 (3.3) GHz) Core G3420 (2C/2T, (4C/8T, 3.1 (3.9) GHz) v3 v3
• Intel Pentium G2010 3.2 GHz, 3 MB cache) • Intel Core i5-4570S (4C/8T, 2.3 (3.3) GHz) (4C/8T, 2.3 (3.3) GHz)
(2C/2T, 2.8 GHz) • Intel Celeron G1820 (4C/4T, 2.9 (3.6) GHz • Intel Core i5-4570TE • Intel Core i5-4570TE
(2C/2T, 2.7 GHz, 2 MB • Intel Pentium G3420 (2C/4T, 2.7 (3.3) GHz) (2C/4T, 2.7 (3.3) GHz)
cache) (2C/2T, 3.2 GHz) • Intel Core i3-4330TE • Intel Core i3-4330TE
(2C/4T, 2.4 GHz) (2C/4T, 2.4 GHz)
Main memory • 2 GB or 4 GB, • 2 GB, • 2 GB, • 2 GB, expandable • 2 GB, expandable
expandable up to expandable up to expandable up to up to 32 GB up to 32 GB
16 GB 16 GB 32 GB • ECC optional • ECC optional
Slots for expansions • 4 x PCI • 4 x PCI • 4 x PCI • 2 x PCI • 7 x PCI
(all long, up to 312 mm) • 1 x PCI Express x16 • 1 x PCI-Express x16 • 1 x PCI-Express x16 • 2 x PCI-Express x16 • 1 x PCI-Express x16
• 1 x PCI-Express x8 • 1 x PCI-Express x16 Gen 3 (8 lanes) • 3 x PCI-Express x4
(1 lane) (2 lanes) • 1 x PCI Express x16 or (1 lane)
• 1 x PCI-Express x1 • 1 x PCI-Express x8 (4 lanes) • 3 x PCI-Express x16 or
(1 lane) • 1 x PCI-Express x8 (4 lanes) • 3 x PCI
(1 lane) • 1 x PCI-Express x16 • 1 x PCI-Express x16
(8 lanes) (8 lanes)
or • 4 x PCI-Express x16
• 2 x PCI-Express x16 (4 lanes)
(4 lanes) • 3 x PCI Express x4
• Available
- Not available
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
General data
2 Drives
SATA hard disks
• Internal installation • • • - •
• Installation at the front - - • • •
in the removable drive bay
• Internal installation - - - • •
in drive holder (shock and
vibration-damped)
RAID1/5 configuration with - - •/• •/- • /•
onboard RAID
RAID configuration with - - • • •
additional hot spare hard disk
Solid-state drive (SSD), MLC - • • • •
Optical drives
DVD-ROM • - • - -
DVD±R/RW • • (Slim) • (Slim) • (Slim) • (Slim)
AC power supply • • • • •
Redundant (optional) - - • • •
Ambient conditions 2)
Vibration/shock load - 0.2 g / 1 g 0.2 g / 1 g 0.5 g / 5 g 0.5 g / 5 g
during operation
Ambient temperature during 5 ... 40 °C With maximum With maximum With maximum With maximum
operation configuration: configuration: configuration: configuration:
5 ... 40 °C 5 ... 40 °C 5 ... 50 °C 5 ... 50 °C
Note: Limitations for
operation of DVD±R/RW
• Available
- Not available
1)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvalds)
2)
Restrictions when using DVD±R/RW and hard disks in removable
drive bay.
■ More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded
from the Internet:
http://www.siemens.com/simatic/printmaterial
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
High flexibility and user friendliness during commissioning,
■ Overview operation and service
• Preinstalled and activated operating system
• IAMT (Intel Active Management Technology) functionality for
remote access to the IPC (remote maintenance)
• Fast restoration of the delivery status of the hard disk(s) thanks
to restore DVD 2
• Low noise output thanks to controlled fans
• Universal implementation as an industrial workstation or
server
• RAID1/RAID5 onboard (a PCI slot is not occupied by the RAID
Controller)
• Flexible applications in many different positions with
telescopic rails or as tower industrial PC
• High degree of flexibility and expandability thanks to
integrated interfaces and 7 slots (PCI and PCI-Express)
High industrial compatibility and compactness for 24-hour
use in an industrial environment
IPC547E long and short enclosure design • Maximum processor performance (in maximum configuration)
without loss of power (throttling) at ambient temperatures of
The SIMATIC IPC547E is a rugged industrial PC in 19" rack up to 40 °C
design (4 U). • Distinct product design with dirt-resistant surfaces
It offers: • Metal enclosure with a high degree of electromagnetic
• Maximum performance compatibility for use in industrial areas and in domestic,
business and commercial environments
• Attractive price
• Suitable for installing in space-saving control cabinets only
• Intel Core i technology 400 mm deep
• Dust protection thanks to overpressure ventilation concept
■ Benefits with fan on the front and dust filter
Maximum system performance for complex automation • Special hard disk holders and card retainers for protection
and visualization tasks against vibration and shock
• State-of-the-art PC technology (e.g. Intel Core i processors Cost reductions through high investment security
4th generation with Turbo Boost 2.0, hyper-threading and
• Availability of at least 1.5 years, guaranteed availability of
virtualization technology)
spare parts for 3 years
• Memory and graphics controller integrated into processor for
• System-tested with SIMATIC components
extraordinary memory and graphics performance
• Certification for worldwide marketing (cULus)
• Maximum performance (e.g. Intel Q87 chipset, DDR3 1600
memory with support of dual channel technology) • Support for legacy interfaces (PS/2, COM, LPT)
• High data transfer rates (e.g. with serial ATA solid-state drives • Installation compatible for many device generations
up to 240 GB, serial ATA hard disks up to 1 TB, dual Gigabit • Worldwide service and support
Ethernet, PCI Express 3.0 technology)
Reduction in downtimes through high system availability
• Secure 24-hour operation (high MTBF, variable-speed fan)
• Efficient self-diagnostics (front status LEDs for fan and
temperature, SIMATIC IPC DiagMonitor)
• High degree of data security due to RAID1 (mirror disk
system) or RAID5 (striping with parity), also with additional hot
spare hard disk
• "Hot swap" removable drive bay in RAID configuration
(replacement of hard disk during operation)
• Fast identification and replacement of the hard disk in the
event of a fault by means of HDD alarm LEDs for RAID config-
urations
• Solid-state drive option in conjunction with RAID1 (data in the
RAID1 network on hard disks, preinstalled and activated
operating system on solid-state drive)
• Redundant power supply with "hot swap" functionality
(replacement of power supply module during operation)
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
■ Technical specifications
IPC547E IPC547E
(enclosure depth 356 mm) (enclosure depth 446 mm)
General features
2 Design
Processors
19" rack PC, 4 U
• Intel Pentium Dual Core G3420 • Intel Core i7-4770S
(2C/2T, 3.2 GHz, 3 MB cache) (4C/8T, 3.1 (3.9) GHz, 8 MB cache, iAMT)
• Intel Celeron G1820 • Intel Core i5-4570S
(2C/2T, 2.7 GHz, 2 MB cache) (4C/4T, 2.9 (3.6) GHz, 6 MB cache, iAMT)
• Intel Pentium Dual Core G3420
(2C/2T, 3.2 GHz, 3 MB cache)
Chipset • Intel H81 • Intel Q87
Main memory • From 2 GB DDR3-1600 SDRAM • From 2 GB DDR3-1600 SDRAM
• Dual channel support • Dual channel support
• 2 DIMM base • 4 DIMM base
• Expandable up to 16 GB 1) • Expandable up to 32 GB 1)
Spare slots for expansions (all long) • 1 x PCI-Express x16 • 1 x PCI-Express x16
• 1 x PCI-Express x16 (2 lanes) • 1 x PCI-Express x16 (4 lanes)
• 1 x PCI-Express x8 (1 lane) • 1 x PCI-Express x8 (1 lane)
• 4 x PCI • 4 x PCI
Graphics • Onboard Intel HD / Intel HD graphics 4600 graphics controller integrated into the processor
Dynamic video memory up to 1.7 GB; up to 3840 x 2160 pixels at 60 Hz image refresh rate and 32-bit colors
• PCI Express graphics card (Dual Head: 2 x VGA or 2 x DVI-D) in the PCIe x16 slot (optional), 512 MB;
up to 2048 x 1536 pixels at 60 Hz image refresh rate and 32-bit colors
Operating Systems • Without • Without
Preinstalled and activated (supplied on restore DVD): Preinstalled and activated (supplied on restore DVD):
• Windows 7 Ultimate MUI (32/64-bit) • Windows 7 Ultimate MUI (32/64-bit)
MUI (Multilanguage User Interface, 5 languages): • Windows Server 2008 R2 incl. 5 Client MUI (64 bit)
English, German, French, Italian, Spanish MUI (Multilanguage User Interface, 5 languages):
Project-specific on request: English, German, French, Italian, Spanish
• Linux 2) Project-specific on request:
• Other • Linux 2)
• Other
Power supplies • 100 ... 240 V AC, 50 ... 60 Hz, • 100 ... 240 V AC, 50 ... 60 Hz,
with bridging of short-term power failures: with bridging of short-term power failures:
max. 20 ms at 0.85 % rated voltage max. 20 ms at 0.85 % rated voltage
• Redundant 2 x 100 ... 240 V AC, 50 ... 60 Hz
Drives
Hard disks, SATA 3.5" Internal installation Internal installation
with NCQ technology • 1 x 500 GB HDD • 1 x 500 GB HDD
Solid-state drives, SATA 2.5" • 1 x 1 TB HDD • 1 x 1 TB HDD
with MLC technology • 2 x 1 TB HDD • 2 x 1 TB HDD
• 1 x 240 GB SSD
• RAID1, 1 TB (2 x 1 TB HDD, mirror disks) 3)
Installation at the front in swap frame (low-profile)
• 1 x 500 GB HDD
• 1 x 1 TB HDD
• 2 x 1 TB HDD
• 1 x 240 GB SSD
• RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
• RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
+ 1 x 1 TB HDD as hot spare
• RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
+ 1 x 240 GB SSD (operating system installed on SSD if
configured)
• RAID5, 2 TB (3 x 1 TB HDD, striping with parity),
"hot swap" 3)
• RAID5, 2 TB (3 x 1 TB HDD, striping with parity),
"hot swap" 3)
+ 1 x 1 TB HDD as hot spare
DVD±R/RW, 5.25" (slim), SATA - • 8 x 8 x 6 x (DVD media)
• 24 x 10 x 16 x (CD media)
Slots for drives Internal: Front:
• 2 x 3.5" • 3 x 5.25" / 4 x low-profile swap frame
• 1 x 5.25" (slimline)
Internal:
• 2 x 3.5"
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
2
1 x DVI-I, 6 x USB 2.0 at the rear, single channel;
2 x PS/2, audio; • 4 GB DDR3 SDRAM (2 x 2 GB), 2
7 slots: 2 x PCIe x16, dual channel;
1 x PCIe x8, 4 x PCI;
temperature and fan monitoring; • 8 GB DDR3 SDRAM 2) (2 x 4 GB), 3
watchdog; card retainers; dual channel;
• 16 GB DDR3 SDRAM 2) 4
Processors and mainboards (2 x 8 GB), dual channel;
• Celeron G1820 A • 32 GB DDR3 SDRAM 2) 5
(2C/2T, 2.7 GHz, 2 MB cache); (4 x 8 GB), dual channel;
1 x Gigabit Ethernet (IE/PN),
1 x DisplayPort V1.2 (only in Type of enclosure and swap media
combination with short enclosure) • Enclosure (short), painted on the 0
• Pentium Dual Core G3420 C front, no removable media;
(2C/2T, 3.2 GHz, 3 MB cache); • Enclosure, painted on the front, no 1
1 x Gigabit Ethernet (IE/PN), removable media;
1 x DisplayPort V1.2 (only in • Enclosure, painted on the front, 2
combination with short enclosure) + DVD±RW (slimline);
• Pentium Dual Core G3420 D • Unpainted enclosure, no remov- 3
(2C/2T, 3.2 GHz, 3 MB cache); able media;
2 x Gigabit Ethernet (IE/PN),
2 x DisplayPort V1.2, 2 x USB 3.0 • Painted enclosure, + DVD±RW 4
at rear, (slimline);
1 x USB 2.0 internal, 1 x COM1; Expansions (hardware)
• Core i5-4570S H • Without expansions (hardware), 0
(4C/4T, 2.9 (3.6) GHz, 6 MB onboard graphics;
cache, iAMT);
• Without expansions (hardware), 1
2 x Gigabit Ethernet (IE/PN),
onboard graphics; DVI-I adapter
2 x DisplayPort V1.2, 2 x USB 3.0
cable, VGA-compliant for onboard
at rear,
graphics;
1 x USB 2.0 internal, 1 x COM1;
• Serial (COM2) & parallel (LPT), 2
• Core i7-4770S K
onboard graphics;
(4C/8T, 3.1 (3.9) GHz, 8 MB
cache, iAMT); • Serial (COM2) and parallel (LPT), 3
2 x Gigabit Ethernet (IE/PN), onboard graphics; DVI-I adapter
2 x DisplayPort V1.2. 2 x USB 3.0 cable, VGA-compliant for onboard
at rear, graphics;
1 x USB 2.0 internal, 1 x COM1; • Serial (COM2) & parallel (LPT) + 4
PCIe x16 graphics card
Drives (SATA) (Dual Head: 2 x VGA or 2 x DVI-D),
• 1 x 500 GB HDD, internal; A 512 MB;
• 1 x 1 TB HDD, internal; B Operating systems
• 2 x 1 TB HDD, internal; D (preinstalled and activated)
• 1 x 240 GB SSD, internal; E • Windows 7 Ultimate, MUI A
• RAID1, 1 TB (2 x 1 TB HDD, mirror G (Eng, Ger, Fr, It, Sp), 32-bit, SP1;
disks), internal; • Windows 7 Ultimate, MUI B
(Eng, Ger, Fr, It, Sp), 64-bit, SP1;
• 1 x 500 GB HDD in removable H
drive bay, at the front; • Windows Server 2008 R2 Stan- F
• 1 x 1 TB HDD in removable drive K dard Edition incl. 5 clients, MUI
bay, at the front; (Eng, Ger, Fr, It, Sp), 64-bit, SP1;
• Without operating system; X
• 2 x 1 TB HDD in removable drive M
bay, at the front;
Expansions (software)
• 1 x 240 GB SSD in removable N
drive bay, at the front; • SIMATIC IPC DiagMonitor V4.4 A
software included;
• RAID1, 1 TB (2 x 1 TB HDD, mirror P
disks) in removable drive bay, • SIMATIC IPC Image & Partition B
hot swap, at the front; Creator V3.3 software included;
• RAID1, 1 TB (2 x 1 TB HDD, mirror Q • SIMATIC IPC DiagMonitor V4.4 + C
disks) in removable drive bay; Image & Partition Creator V3.3
hot swap + 1 x 1 TB HDD as hot software included;
spare in removable drive bay, • Without expansions (software); X
at the front; • Without expansions (software) / Y
• RAID1, 1 TB (2 x 1 TB HDD, mirror R TPM (not for China and Russia);
disks) in removable drive bay, hot
swap + 240 GB SSD in removable Country-specific versions/
drive bay, at the front (operating power supplies:
system installed on SSD if config- • 100/240 V AC industrial power 0
ured); supply, Europe power cable;
• RAID5, 2 TB (3 x 1 TB HDD, S • 100/240 V AC industrial power 4
striping with parity) in removable supply, USA power cable;
drive bay, hot swap, at the front; • 100/240 V AC industrial power 5
• RAID5, 2 TB (3 x 1 TB HDD, T supply, China power cable;
striping with parity) in removable • 2 x 100/240 V AC redundant 6
drive bay, hot swap + 1 x 1 TB industrial power supply, without
HDD as hot spare in removable power cable;
drive bay, at the front;
1) For an up-to-date overview, see the SIMATIC PC Online Configurator at:
https://www.siemens.com/ipc-configurator
2)
Can only be used with 64-bit operating systems
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547E
2
(2C/2T, 3.2 GHz, 3 MB cache); • 4 GB DDR3 SDRAM (1 x 4 GB) 6ES7648-2AJ60-0MA0
2x USB 3.0 on front, 6x USB 2.0 at • 8 GB DDR3 SDRAM (1 x 8 GB) 6ES7648-2AJ70-0MA0
the rear, 1x Gbit Ethernet,
1x DisplayPort V1.2, 1x DVI-I, Tower Kit 6ES7648-1AA00-0XC0
2x PS/2, audio; painted enclosure For converting the computer into an
(short) no removable media; industrial tower PC
1x 1 TB HDD, internal (0.2 g vibra-
tion, 1 g shock); Retainer 6ES7648-1AA00-0XK0
2 GB DDR3 SDRAM (1x 2 GB), for interlocking the internal
single-channel; serial (COM2) + USB port
parallel (LPT), onboard graphics,
DVI-I adapter cable VGA-compli- Adapter cable
ant for onboard graphics; • DisplayPort to DVI-D for onboard 6ES7648-3AF00-0XA0
without operating system; graphics
without expansions (software); • DisplayPort to VGA for onboard 6ES7648-3AG00-0XA0
100/240 V AC industrial power graphics
supply, Europe power cable;
Power cable, straight, 3 m long
• Pentium Dual Core G3420 6AG4104-3DB24-3XX0
• Austria, Belgium, Finland, France, 6ES7900-0AA00-0XA0
(2C/2T, 3.2 GHz, 3 MB cache);
Germany, Netherlands, Spain,
2x USB 3.0 on front, 2x USB 3.0
Sweden
and 6x USB 2.0 at the rear,
1 x USB 2.0 internal, • United Kingdom 6ES7900-0BA00-0XA0
2x Gbit Ethernet, • Switzerland 6ES7900-0CA00-0XA0
2x DisplayPort V1.2, • USA 6ES7900-0DA00-0XA0
1x DVI-I, 1x COM1, 2x PS/2, • Italy 6ES7900-0EA00-0XA0
Audio; painted enclosure +
DVD±RW (slimline); • China 6ES7900-0FA00-0XA0
1x 1 TB HDD, internal; Rack unit for low-profile 6ES7648-0EG01-1BA0
4 GB DDR3 SDRAM (2x 2 GB), removable drive bay
dual channel; serial (COM2) +
parallel (LPT), onboard graphics, for 3.5" hard drive (SATA/SAS) and See catalog ST 80/ST PC
DVI-I adapter cable VGA-compli- 2.5" SSD (SATA), without drive
ant for onboard graphics;
Expansion components See Expansion components
without operating system;
without expansions (software);
100/240 V AC industrial power
supply, Europe power cable;
Note:
• Core i5-4570S (4C/4T, 2.9 (3.6) 6AG4104-3HP24-3AX0 Software Packages with SIMATIC WinCC flexible,
GHz, 6 MB cache, iAMT); SIMATIC WinCC RT Advanced, SIMATIC WinCC,
2x USB 3.0 on front, 2x USB 3.0 and SIMATIC WinAC RTX (F) can be ordered together with the
and 6x USB 2.0 at the rear, 1x USB
2.0 internal, 2x Gbit Ethernet, SIMATIC IPC at favorable prices.
2x DisplayPort V1.2, 1x DVI-I,
1x COM1, 2x PS/2, Audio; painted
More information under "Embedded Bundles / Packages
enclosure + DVD±RW (slimline); for industrial PCs".
RAID1, 1 TB (2x 1 TB HDD, mirror
disks) in the removable drive bay,
hot-swap, on front; ■ More information
4 GB DDR3 SDRAM (2x 2 GB),
dual channel; serial (COM2) + Further information can be found in the Internet at:
parallel (LPT), onboard graphics, http://www.siemens.com/simatic-pc
DVI-I adapter cable VGA-compli-
ant for onboard graphics;
Windows 7 Ultimate,
Multi Language (Eng, Ger, Fr, It,
Sp), 32-bit, SP1;
without expansions (software);
100/240 V AC industrial power
supply, Europe power cable;
• Core i7-4770S (4C/8T, 3.1 (3.9) 6AG4104-3KP34-4BX6
GHz, 8 MB cache, iAMT);
2x USB 3.0 on front, 2x USB 3.0
and 6x USB 2.0 on rear, 1x USB
2.0 internal, 2x Gbit Ethernet, 2x
DisplayPort V1.2, 1x DVI-I, 1x
COM1, 2x PS/2, audio; painted
enclosure + DVD±RW (slimline);
RAID1, 1 TB (2x 1 TB HDD, mirror
disks) in removable drive bay,
hot-swap, on front;
8 GB DDR3 SDRAM (2x 4 GB),
dual channel; serial (COM2) +
parallel (LPT) + PCIe x16 graphics
card (dual-head:
2x VGA or 2x DVI-D), 512 MB;
Windows 7 Ultimate, multi-
language (En, Ger, Fr, It, Sp),
64-bit, SP1;
without expansions (software);
2x 100/240 V AC redundant
industrial power supply, without
power cable;
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
High flexibility and user friendliness during commissioning,
■ Overview operation and service
• Preinstalled and activated operating system
• IAMT (Intel Active Management Technology) functionality for
remote access to the IPC (remote maintenance)
• Fast restoration of the delivery status of the hard disk(s) thanks
to restore DVD 2
• Low noise output thanks to controlled fans
• Universal implementation as an industrial workstation or
server
• RAID1/RAID5 onboard (a PCI slot is not occupied by the RAID
Controller)
• Flexible applications in many different positions with
telescopic rails or as tower industrial PC.
• High degree of flexibility and expandability thanks to
integrated interfaces and 7 slots (PCI and PCI-Express)
High industrial compatibility and compactness for 24-hour
use in an industrial environment
• Maximum processor performance (in maximum configuration)
The SIMATIC IPC547D is a rugged industrial PC in 19" rack without loss of power (throttling) at ambient temperatures of
design (4 U). up to 40 °C
It offers: • Distinct product design with fully-coated, dirt-resistant
• Maximum performance surfaces
• Attractive price • Metal enclosure with a high degree of electromagnetic
compatibility for use in industrial areas and in domestic,
• Intel Core i technology
business and commercial environments
• Suitable for installing in space-saving control cabinets only
■ Benefits 500 mm deep
Maximum system performance for complex automation • Dust protection thanks to overpressure ventilation concept
and visualization tasks with fan on the front and dust filter
• State-of-the-art PC technology (e.g. Intel Core i processors • Special hard disk holders and card retainers for protection
2nd generation with Turbo Boost 2.0, hyper-threading and against vibration and shock
virtualization technology)
Cost reductions through high investment security
• Memory and graphics controller integrated into processor for
extraordinary memory and graphics performance • Availability of at least 1.5 years, guaranteed availability of
spare parts for 3 years
• Maximum performance (e.g. Intel Q67 chipset, DDR3 1333
memory with support of dual channel technology) • System-tested with SIMATIC components
• High data transfer rates (e.g. with serial ATA Solid-State Drive • Certification for worldwide marketing (cULus)
(SLC) with 50 GB, serial ATA hard disks up to 1 TB, • Support for legacy interfaces (PS/2, COM, LPT)
Dual Gigabit Ethernet, PCI-Express 2.0 technology) • Installation compatible for many device generations
Reduction in downtimes through high system availability • Worldwide service and support
• Secure 24-hour operation (high MTBF, variable-speed fan)
• Efficient self-diagnostics (front status LEDs for fan and
temperature, SIMATIC IPC DiagMonitor)
• High degree of data security due to RAID1 (mirror disks
system) or RAID5 (striping with parity)
• "Hot swap" removable drive bay in RAID configuration
(replacement of hard disk during operation)
• Fast identification and replacement of the hard disk in the
event of a fault by means of HDD alarm LEDs for RAID
configurations
• Solid-State Drive (SSD) in single level cell (SLC) architecture
• Redundant power supply with "hot swap" functionality
(replacement of power supply module during operation)
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
■ Technical specifications
SIMATIC IPC547D SIMATIC IPC547D
General features Drives
Design 19" rack, 4 U, externally painted Hard disk, SATA 3.5" Installation in internal drive support
2 Processor • Intel Core i7-2600
(4C/8T, 3.40 GHz, 8 MB Last Level
with NCQ technology
Solid State Drive, SATA 2.5"
• 500 GB
• 1 TB
with SLC technology • RAID1 2)
Cache, Turbo Boost 2.0, EM64T, 1 TB (2 x 1 TB, mirror disks)
VT-x/-d, iAMT) • 50 GB solid-state drive
• Intel Core i5-2400
(4C/4T, 3.10 GHz, 6 MB Last Level Installation at the front in removable
Cache, Turbo Boost 2.0, EM64T, drive bay (low profile)
VT-x/-d, iAMT) • 500 GB
• Intel Pentium Dual Core G850 • 2 x 500 GB
(2C/2T, 2.90 GHz, 3 MB Last Level • RAID1 2) 1 TB
Cache, EM64T, VT) (2 x 1 TB, mirror disks), "hot swap"
• RAID5 2) 2 TB
Chipset • Intel Q67 (3 x 1 TB, striping with parity),
Main memory • From 1 GB DDR3 1333 SDRAM "hot swap"
• Dual channel support • 50 GB solid-state drive
• 4 DIMM base • RAID1 2)
1 TB (2 x 1 TB, mirror disks),
• Expandable up to 32 GB 1)
"hot swap" + 50 GB solid-state drive
Spare slots for expansions (all long) • 4 x PCI (operating system installed on SSD
• 1 x PCI Express x16 if configured)
• 1 x PCI-Express x16 (4 lanes)
• 1 x PCI-Express x8 (1 lane) DVD-ROM, 5.25", SATA • 16 x (DVD media)
• 32 x (CD media)
Graphic • Onboard Intel HD 2000 graphics
controller integrated into the DVD±R/RW, 5.25", SATA • 16 x 24 x 8 x (DVD media)
• 48 x 48 x 32 x (CD media)
processor; Shared Video Memory
up to 1.7 GB; Slots for drives Front:
up to 2560 x 1600 pixels at 60 Hz • 3 x 5.25"
image refresh rate and 32-bit colors • 1 x 3.5"
• PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D) Internal:
in the PCIe x16 slot; 512 MB; • 2 x 3.5"
up to 2048 x 1536 pixels at 85 Hz Ports
image refresh rate and 32 bit colors
(optional) Ethernet 2 x Intel Gbit Ethernet
(RJ45, teaming-capable)
Operating system • Without
USB 2.0 • 2 x front (high current)
Preinstalled and activated (supplied • 8 x rear (high current)
on restore DVD): • 1 x internal (high current), e.g.
• Windows XP Professional MUI for USB dongle with optional
(32-bit) interlocking
• Windows 7 Ultimate MUI (32/64-bit)
• Windows Server 2008 Serial 9-pole COM1 (V.24); COM2 (V.24)
• incl. 5 Client MUI (32 bit) (optional)
• Windows Server 2008 R2
• incl. 5 Client MUI (64 bit) Parallel LPT (optional)
MUI (Multilanguage User Interface, VGA Optionally via adapter cable
5 languages): English, German,
DVI-I 1x
French, Italian, Spanish
Project-specific on request: DisplayPort 1x
• Linux 3) Keyboard PS/2
• Other
Mouse PS/2
Power supply • 100 ... 240 V AC, 50 ... 60 Hz,
with bridging of short-term power Audio 1 x Line In;
failures: max. 20 ms at 0.85% rated 1 x Line Out;
voltage 1 x Mic.
• Redundant 100 ... 240 V AC,
50 ... 60 Hz
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
Temperature
software
When permitted operating tempera-
Emitted interference EN 61000-6-3; EN 61000-6-4;
CISPR 22 / EN 55022 Class B;
FCC Class A; EN 61000-3-2 Class D;
2
ture range is exceeded EN 61000-3-3
Fan Speed monitoring Immunity to conducted interference • ± 2 kV (IEC 61000-4-4, burst)
• 1 x front fan on the supply lines • ± 1 kV
• 1 x CPU fan (IEC 61000-4-5, symm. surge)
• 1 x power supply fan • ±2 kV
Watchdog • Monitoring of program execution (IEC 61000-4-5, asymm. surge)
• Monitoring time can be parameter- Noise immunity on signal lines • ±2 kV (IEC 61000-4-4, burst,
ized in software length > 30 m)
Monitoring functions via the network SIMATIC IPC DiagMonitor Version • ± 1 kV (IEC 61000-4-4, Burst,
V4.3.x.x or higher (optional) Length < 30 m),
• ± 2 kV (IEC 61000-4-5, Surge,
Remote monitoring capability for: Length > 30 m)
• Watchdog
• Temperature Immunity to static discharge • ±4 kV, contact discharge
• Fan speed (IEC 61000-4-2)
• Battery • ±8 kV, air discharge
• Hard disks (SMART) (IEC 61000-4-2)
• System/Ethernet
Immunity to high radio frequency • 1 V/m 80% AM; 2 ... 2.7 GHz
Communication: interference (IEC 61000-4-3)
• Ethernet interface (SNMP protocol) • 10 V/m 80% AM;
• OPC for integration in SIMATIC 80 MHz ... 1 GHz and
software 1.4 GHz … 2 GHz (IEC 61000-4-3);
• Client server architecture • 10 V, 10 kHz ... 80 MHz
• Structure of log files (IEC 61000-4-6)
Front LEDs • POWER (PC switched on) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
• HDD (access to hard disk)
• TEMP (temperature monitoring) Ambient temperature during 5 ... 40 °C
• FAN (fan monitoring) operation Note:
Additional HDD alarm LEDs for RAID Limitations for operation of
configurations behind the front flap DVD±R/RW
Environmental conditions Humidity during operation 5 ... 80 % at 25 °C (no condensation)
Degree of protection IP30 front, IP20 rear Approvals and safety regulations
according to EN 60529 Safety regulations IEC 60950-1; UL60950; CSA
Dust protection With the front door closed Approvals cULus 60950
according to IEC 60529 filter class
G2 EN 779, 99% of particles > CE mark For use in industrial areas
0.5 mm are filtered as well as domestic, business and
commercial environments:
Protection class Protection class I • Emitted interference:
according to IEC 61140 EN 61000-6-3:2007
Vibration load during operation 4) IEC 60068-2-6, 10 cycles • Noise immunity:
• 20 ... 58 Hz: 0.015 mm EN 61000-6-2:2005
• 58 ... 200 Hz: 2 m/s2 (approx. 0.2 g) Dimensions and weights
Shock load in operation 4) IEC 60068-2-27 Installation dimensions 434 x 177 x 446
• Half-sine: 9.8 m/s2, 20 ms (W x H x D) in mm
(approx. 1 g), 100 shocks per axis
Weight, approx. 19 kg
1) Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system
is required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
2) SATA RAID controller onboard in Intel Q67 chipset
3) Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvalds).
4) Restrictions in use of optical drives and HDD in removable drive bays.
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
2
1 x DisplayPort,
1 x DVI-I, 8 x USB on the rear, • DVD±RW 2
2 x USB on the front, Expansions (hardware)
1 x USB internal, 1 x serial (COM1),
2 x PS/2, audio; • Without expansions (HW); 0
7 slots (all long): onboard graphics
4 x PCI, 1 x PCIe x16, • No expansions (HW); 1
1 x PCIe x16 (4 lanes), • onboard graphics;
1 x PCIe x8 (1 lane); DVI-I VGA-compliant adapter
mounting locations: 6 (3 x 5.25", • cable for onboard graphics
1 x 3.5" externally accessible; • Serial (COM2) & parallel (LPT); 2
2 x 3.5" internal); onboard graphics
temperature and fan monitoring; • Serial (COM2) and parallel (LPT); 3
watchdog; card retainer onboard graphics;
Processors DVI-I VGA-compliant adapter
• cable for onboard graphics
• Pentium Dual Core G850 A
(2C/2T, 2.90 GHz, 3 MB Last Level • Serial (COM2) & parallel (LPT) + 4
Cache, EM64T, VT) PCIe x16 graphics card (Dual
Head: 2 x VGA or 2 x DVI-D),
• Core i5-2400 (4C/4T, 3.10 GHz, C
512 MB
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT) Operating systems
• Core i7-2600 (4C/8T, 3.40 GHz, D (preinstalled and activated)
8 MB Last Level Cache, Turbo • Windows XP Professional, MUI B
Boost 2.0, EM64T, VT-x/-d, iAMT) (Eng, Ger, Fr, It, Sp), 32-bit, SP3
Drives • Windows 7 Ultimate, MUI (Eng, E
Ger, Fr, It, Sp), 32-bit, SP1
• 500 GB HDD SATA; internal A
• Windows 7 Ultimate, MUI F
• 1 TB HDD SATA; internal B (Eng, Ger, Fr, It, Sp), 64-bit, SP1
• RAID1, 1 TB (2 x 1 TB HDD SATA, D • Windows Server 2008 Standard P
mirror disks); internal 1) Edition incl. 5 Client, MUI
• 50 GB solid-state drive (SLC) E (Eng, Ger, Fr, It, Sp), 32 bit, SP2
SATA; internal • Windows Server 2008 R2 Stan- Q
• 500 GB HDD SATA G dard Edition including 5 clients,
in removable drive bay; front MUI (Eng, Ger, Fr, It, Sp), 64-bit,
• 2 x 500 GB HDD SATA H SP1
in removable drive bay; front • Without operating system X
• RAID1, 1 TB (2 x 1 TB HDD SATA, P
mirror disks) in removable drive Expansions (software)
bay; for hot swapping; • SIMATIC IPC DiagMonitor V4.3 A
at the front software included
• RAID5, 2 TB (3 x 1 TB HDD SATA, R • SIMATIC IPC Image & Partition B
striping with parity) in removable Creator V3.2 software included
drive bay; for hot swapping;
• SIMATIC IPC DiagMonitor V4.3 + C
at the front
Image & Partition Creator V3.2
• 50 GB solid-state drive (SLC) S software included
SATA in removable drive bay;
• Without expansions (software) X
at the front
• RAID1, 1 TB (2 x 1 TB HDD SATA, T Power supply,
mirror disks) in removable drive with country-specific cable:
bay; hot swapping; at the front +
50 GB solid-state drive (SLC) • 100/240 V AC 0
SATA in removable drive bay; industrial power supply;
at the front (operating system power cable for Europe
installed on SSD, if configured) • 100/240 V AC 4
industrial power supply;
Memory configuration USA power cable
• 1 GB DDR3 SDRAM 0 • 100/240 V AC 5
(1 x 1 GB), single channel industrial power supply;
• 2 GB DDR3 SDRAM 1 power cable for China
(2 x 1 GB), dual channel • 2 x 100/240 V AC 6
• 4 GB DDR3 SDRAM 2 redundant industrial power
(2 x 2 GB), dual channel supply;
• 8 GB DDR3 SDRAM 2) 3 without power cable
(2 x 4 GB), dual channel
1)
• 16 GB DDR3 SDRAM 2) 4 Not in combination with redundant power supply
(4 x 4 GB), dual channel 2)
Can only be used on 64-bit operating systems
• 32 GB DDR3 SDRAM 2) 5 3)
For an up-to-date overview, see the SIMATIC PC online configurator at:
(4 x 8 GB), dual channel www.siemens.com/ipc-configurator
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
2
(2C/2T, 2.90 GHz, 3 MB Last Level (1 x 1 GB)
Cache, EM64T, VT); • 2 GB DDR3 1333 SDRAM, DIMM, 6ES7648-2AJ50-0LB0
500 GB HDD SATA internal; kit for dual-channel technology
1 GB DDR3 SDRAM (1 x 1 GB), (2 x 1 GB)
single channel; • 4 GB DDR3 1333 SDRAM, DIMM, 6ES7648-2AJ60-0LB0
DVD-ROM; interfaces: kit for dual-channel technology
2 x Gbit Ethernet (RJ45), (2 x 2 GB)
1 x serial, 8 x USB rear, • 8 GB DDR3 1333 SDRAM, DIMM, 6ES7648-2AJ70-0LB0
2 x USB front, 1 x USB internal, kit for dual-channel technology
2 x PS/2, audio; (2 x 4 GB)
100/240 V industrial power supply,
power cable for Europe; Tower Kit 6ES7648-1AA00-0XC0
without operating system For converting the computer
into an industrial tower PC
• Core i5-2400 (4C/4T, 3.10 GHz, 6AG4104-2CP22-2XX0
6 MB Last Level Cache, Turbo Retainer 6ES7648-1AA00-0XK0
Boost 2.0, EM64T, VT-x/-d, iAMT); for pin assignment of the internal
RAID1, 1 TB (2 x 1 TB HDD SATA, USB port
mirror disks) in removable drive
bay, for hot swapping, at the front; Power cable, straight, 3 m long
4 GB DDR3 SDRAM (2 x 2 GB) • Austria, Belgium, Finland, France, 6ES7900-0AA00-0XA0
dual channel; DVD±RW; Germany, Netherlands, Spain,
interfaces: Sweden
2 x Gbit Ethernet (RJ45), • United Kingdom 6ES7900-0BA00-0XA0
2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front, • Switzerland 6ES7900-0CA00-0XA0
1 x USB internal, 2 x PS/2, Audio; • USA 6ES7900-0DA00-0XA0
100/240 V industrial power supply, • Italy 6ES7900-0EA00-0XA0
power cable for Europe; • China 6ES7900-0FA00-0XA0
without operating system
Rack unit for low-profile HDD 6ES7648-0EG00-1BA0
• Core i7-2600 (4C/8T, 3.40 GHz, 6AG4104-2DP32-2FX0 removable drive bay
8 MB Last Level Cache, Turbo
for 3.5" hard disk, SATA
Boost 2.0, EM64T, VT-x/-d, iAMT);
(without hard disk)
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in removable drive Expansion components See catalog ST 80 / ST PC
bay, for hot swapping, at the front;
8 GB DDR3 SDRAM (2 x 4 GB)
dual channel; DVD±RW;
interfaces:
2 x Gbit Ethernet (RJ45), Note:
2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front, Software Packages with SIMATIC WinCC flexible,
1 x USB internal, 2 x PS/2, audio; SIMATIC WinCC RT Advanced, SIMATIC WinCC,
100/240 V industrial power supply, and SIMATIC WinAC RTX (F) can be ordered together with the
power cable for Europe,
Windows 7 Ultimate MUI SIMATIC IPC at favorable prices.
(Eng, Ger, Fr, It, Sp), More information under "Embedded Bundles / Packages
64-bit, SP1 supplied
for industrial PCs".
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
Reduction in downtimes through high system availability
■ Overview • Secure 24-hour operation (high MTBF, variable-speed fan) at
ambient temperature up to 50 °C
• High degree of data security thanks to RAID configurations
(RAID controllers onboard)
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
■ Technical specifications
SIMATIC IPC647D SIMATIC IPC647D
General features Drives
Design 19" rack, 2 U, external coating Serial ATA 3.5" hard disks (HDD) Mounted internally on the permanent
Processor • Intel® Xeon™ E3-1268L v3
4C/8T, 2.3 (3.3) GHz, 8 MB cache,
with NCQ technology and hard disk support:
serial ATA 2.5" solid-state drive (SSD) • 1x 240 GB SSD
2
turbo-boost 2.0, Extended Memory with MLC technology Mounted internally in vibration/shock-
64 (EM64) and virtualization absorbing hard disk support
technology (VT-x/-d), iAMT 9.0 • 1 x 500 GB HDD
• Intel® Core™ i5-4570TE • 1 x 1 TB HDD
2C/4T, 2.7 (3.3) GHz, 4 MB cache, • 2 x 1 TB HDD
turbo-boost 2.0, Extended Memory • RAID13), 1 TB
64 (EM64) and virtualization (2 x 1 TB HDD, mirror disks)
technology (VT-x/-d), iAMT 9.0 Installed on the front in the low-profile
• Intel® Core™ i3-4330TE removable drive bay (hot swapping
2C/4T, 2.4 GHz, 4 MB cache, in RAID configurations):
Extended Memory 64 (EM64) and • 1 x 500 GB HDD
virtualization technology (VT-x) • 1 x 1 TB HDD
Chipset Intel C226 • 2 x 1 TB HDD
• 1 x 240 GB SSD
Main memory • From 2 GB DDR3 1600 SDRAM • RAID13), 1 TB
• Dual channel support (2 x 1 TB HDD, mirror disks)
• 4 DIMM bases expandable
up to 32 GB 1) DVD±R/RW, 5.25", SATA • 8 x 8 x 6 x (DVD media)
• ECC memory (optional) • 24 x 10 x 16 x (CD media)
Spare slots for expansions (all long) PCI slots (2 PCI, 2 PCI-Express): Slots for drives Front:
• 2 x PCI • 2 x low profile removable drive bays
• 2 x PCI-Express x16 (8 lanes) Gen 3 (for 3.5" HDD)
• 1 x 12.7 mm slimline
or PCI-Express slots (for ODD or SSD)
(4 PCI-Express):
• 1 x PCI-Express x16 (4 lanes) Gen 3 Internal:
• 1 x PCI-Express x16 (4 lanes) Gen 2 • 2 x 3.5" as an alternative to remov-
• 1 x PCI-Express x16 (4 lanes) Gen 3 able drive bays
• 1 x PCI-Express x16 (8 lanes) Gen 3 (in the optional, shock and
vibration-damped drive cage)
Graphics • Onboard Intel HD 4600 graphics
controller integrated into the Interfaces
processor PROFINET 3 x RJ45 (CP 1616-compatible),
Dynamic video memory up to optional
1.7 GB, up to 3840 x 2160 pixels
at 60 Hz image refresh rate and PROFIBUS/MPI 12 Mbit/s
32-bit colors (isolated, compatible with CP 5622),
• PCI Express graphics card optional
(Dual Head: 2 x VGA or 2 x DVI-D) Ethernet 2 x 10/100/1000 Mbit/s
in the PCIe x16 slot (optional) (RJ45, teaming-capable)
512 MB, up to 2048 x 1536 pixels at
60 Hz image refresh rate and USB 3.0 • 1 x front (high current)
32-bit colors • 2 x rear (high current)
• 1 x internal (high current), e.g. for
Operating system • without USB dongle
• Preinstalled, activated, and
supplied on restore DVD USB 2.0 • 1 x front (high current),
• Windows 7 Ultimate MUI, 32/64-bit can be used with door closed
• Windows Server 2008 R2 • 2 x rear (high current)
incl. 5 Client MUI, 64-bit
(MUI: Multi-Language User Serial • 9-pin COM1 (V.24)
Interface; • 9-pin COM2 (V.24) optional
5 languages (English, French, Parallel LPT1 (optional)
German, Italian, Spanish)
• Project-specific on request Linux 2) VGA Optionally via adapter cable
• Other
DVI-I 1x
Power supply • 100 ... 240 V AC, 50 ... 60 Hz;
DisplayPort V1.2 2x
with bridging of temporary power
failures in accordance with NAMUR: Keyboard PS/2
max. 20 ms at 0.85 % rated voltage
• Redundant 100 ... 240 V AC, Mouse PS/2
50 ... 60 Hz Audio 1 x Line Out;
1 x Micro
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
2 Temperature
software
• Overshoot/undershoot of permissi-
Emitted interference (AC) • EN 61000-6-3, FCC Class A
• EN 61000-6-4; CISPR 22, EN 55022
Class B
ble operating temperature range • EN 61000-3-2 Class D,
• Messages can be evaluated by the EN 61000-3-3
application program
Immunity to conducted interference • ± 2 kV (IEC 61000-4-4, burst)
Fan • Speed monitoring on the supply lines • ± 1 kV
• 2 x enclosure fans (IEC 61000-4-5, symm. surge)
• 1 x fan power supply • ± 2 kV
Watchdog • Monitoring of program execution (IEC 61000-4-5, asymm. surge)
• Monitoring time can be parameter- Noise immunity on signal lines • ± 1 kV (IEC 61000-4-4, burst,
ized in software length < 30 m)
• Restart can be parameterized in the • ± 2 kV (IEC 61000-4-4, symm.
event of a fault surge, length > 30 m)
• Messages can be evaluated by the • ± 2 kV (IEC 61000-4-5, asymm.
application program surge, length > 30 m)
Monitoring functions via the network SIMATIC PC DiagMonitor (optional) Immunity to static discharge • ± 6 kV, contact discharge
Remote monitoring capability for: (IEC 61000-4-2)
• Watchdog • ± 8 kV, air discharge
• Temperature (IEC 61000-4-2)
• Fan speed
• Hard disk monitoring (SMART) Immunity to high radio frequency • 10 V/m, 80 to 1000 MHz and
• System/Ethernet monitoring interference 1.4 to 2 GHz, 80% AM
(heartbeat) (according to IEC 61000-4-3)
• 3 V/m, 2 to 2.7 GHz, 80% AM
Communication: (according to IEC 61000-4-3)
• Ethernet interface (SNMP protocol) • 10 V, 10 kHz to 80 MHz, 80% AM
• OPC for integration in SIMATIC (according to IEC 61000-4-6)
software
• Configuration of client/server Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
architectures, configuration of log Ambient temperature during 5 … 50 °C
files operation Note:
Front LEDs • POWER (internal power supply unit, Limitations for operation of
PC switched on) DVD+/-RW
• HDD (access to hard disk)
• ETHERNET1 Humidity during operation 5 ... 85 % at 30 °C (no condensation)
(Ethernet status, "heartbeat") Approvals and safety regulations
• ETHERNET2
(Ethernet status, "heartbeat") Safety regulations • IEC 60950-1
• PROFIBUS/MPI (PROFIBUS status) • EN 60950-1
• SF PROFINET (PROFINET status) • UL 60950-1
• WATCHDOG (ready/fault indication) • CSA C22.2 No 60950-1-07
• TEMP (temperature status)
• FAN (fan speed monitoring) Approvals cULus 60950, KCC
• HDD0 ALARM 4) CE mark For use in industrial areas as well as
• HDD1 ALARM 4) domestic, business and commercial
Ambient conditions environments:
• Emitted interference:
Degree of protection IP41 at the front, EN 61000-6-3: 2007 +A1:2011
IP20 at the rear acc. to EN 60529 • Noise immunity:
EN 61000-6-2:2005
Dust protection with front door closed: G2 EN 779,
99 % of particles > 0.5 mm are held Dimensions and weights
back
Installation dimensions 430 x 88 x 445
Protection class Protection class I (W x H x D) in mm
according to IEC 61140
1) Memory information: In order to use a memory with more than 4 GB,
Vibration load during operation DIN EN 60068-2-6, 10 cycles a 64-bit operating system is required. In the case of configurations with at
Internal mounting of the hard disk least 4 GB, the visible memory can be reduced to about 3.5 GB or less
drives in optional, internal drive cage: (with 32-bit operating systems)
• 10 ... 58 Hz: 0.0375 mm; 2) Suitable for specific LINUX versions in accordance with the specifications
• 58 ... 500 Hz: 5 m/s2 (approx. 0.5 g) of the Siemens manufacturer's declaration "Suitable for LINUX"
Note: (LINUX is a trademark of Linus Torvalds).
There are limitations when DVD+/-RW 3) SATA RAID controller on board in Intel chipset
and HDD are operated in a remov- 4)
able drive bay Hard disk alarm in conjunction with RAID and monitoring software
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
2
Interfaces: 2 x GBIT LAN (RJ45); single channel
1 x DVI-I; 2 x DisplayPort; • 4 GB DDR3 SDRAM (2 x 2 GB), 2
1 x COM; 2 x PS/2; Audio; dual channel
2 x USB 3.0, 2 x USB 2.0 at rear;
1 x USB 3.0, 1 x USB 2.0 at front, • 8 GB DDR3 SDRAM (2 x 4 GB), 3
1 x USB 3.0 internal; dual channel
Temperature and fan monitoring, • 16 GB DDR3 SDRAM (2 x 8 GB), 4
watchdog, card retainer; dual channel
• 32 GB DDR3 SDRAM (4 x 8 GB), 5
Processor/motherboard
dual channel
• Core i3-4330TE D • 8 GB DDR3 SDRAM, (2 x 4 GB), 6
(2C/4T, 2.4 GHz, 4 MB cache); ECC, dual channel
mainboard without fieldbus
• 16 GB DDR3 SDRAM, (2 x 8 GB), 7
• Core i3-4330TE E ECC, dual channel
(2C/4T, 2.4 GHz, 4 MB, VT-x); • 32 GB DDR3 SDRAM, (4 x 8 GB), 8
mainboard with PROFIBUS/MPI ECC, dual channel
(CP 5622-compatible)
• Core i3-4330TE F Bus module / swap media / SSD:
(2C/4T, 2.4 GHz, 4 MB cache); • Bus module 2-slot: 0
mainboard with PROFINET 2 x PCIe x16; without drives
(3 x RJ45, CP 1616-compatible) • Bus module 4-slot: 2 x PCI, 1
• Core i5-4570TE G 2 x PCIe x16; without drives
(2C/4T, 2.7 (3.3) GHz, • Bus module 4-slot: 2
4 MB Cache, TB, VT-d, AMT); 4 x PCIe x16; without drives
mainboard without fieldbus • Bus module 2-slot: 3
• Core i5-4570TE H 2 x PCIe x16; DVD±RW (slim)
(2C/4T, 2.7 (3.3) GHz, • Bus module 4-slot: 2 x PCI, 4
4 MB cache, TB, VT-x, VT-d, AMT); 2x PCIe x16; DVD±RW (slim)
mainboard with PROFIBUS/MPI • Bus module 4-slot: 4 x PCIe x16; 5
(CP 5622-compatible) DVD±RW (slim)
• Core i5-4570TE J 6
(2C/4T, 2.7 (3.3) GHz, • Bus module 2-slot:
4 MB cache, TB, VT-d, AMT); 2 x PCIe x16 / 1 x 240 GB SSD
mainboard with PROFINET (for operating system), internal
(3 x RJ45, CP 1616-compatible) • Bus module 4-slot: 2 x PCI, 7
• Xeon E3-1268L v3 K 2 x PCIe x16 / 1 x 240 GB SSD
(4C/8T, 2.3 (3.3) GHz, (for operating system), internal
8 MB cache, TB, VT-d, AMT); • Bus module 4-slot: 8
mainboard without fieldbus 4 x PCIe x16 / 1 x 240 GB SSD
• Xeon E3-1268L v3 L (for operating system), internal
(4C/8T, 2.3 (3.3) GHz,
8 MB cache, TB, VT-x, VT-d, AMT); Expansion hardware
mainboard with PROFIBUS/MPI • Without expansions (hardware), 0
(CP 5622-compatible) onboard graphics;
• Xeon E3-1268L v3 M • Without expansions (hardware), 1
(4C/8T, 2.3 (3.3) GHz, onboard graphics, DVI-I adapter
8 MB cache, TB, VT-d, AMT); cable, VGA-compliant for onboard
mainboard with PROFINET graphics;
(3 x RJ45, CP 1616-compatible) • Serial (COM2) + parallel 2
(LPT, 1 slot reserved),
Hard drives / SSD onboard graphics;
• 500 GB HDD SATA, internal A • Serial (COM2) + parallel 3
(0.5 g vibration, 5 g shock) (LPT, 1 slot reserved),
• 1 TB HDD SATA, internal B onboard graphics; DVI-I adapter
(0.5 g vibration, 5 g shock) cable, VGA-compliant for onboard
• 2 x 1 TB HDD SATA, internal C graphics;
(0.5 g vibration, 5 g shock) • Serial (COM2) + Parallel 4
(LPT, 1 slot reserved) + PCIe x16
• RAID1, 1 TB D Graphics Card (Dual-Head:
(2 x 1 TB HDD SATA, mirror disks), 2 x VGA or 2 x DVI-D), 512 MB,
internal (0.5 g vibration, 5 g shock) (1 slot reserved);
• 500 GB HDD SATA H
in removable drive bay; front
• 1 TB HDD SATA K
in removable drive bay; front
• 2 x 1 TB HDD SAT M
in removable drive bay; front
• RAID1, 1 TB P
(2 x 1 TB HDD SATA, mirror disks)
in removable drive bay,
hot-swappable, front
• 240 GB SSD SATA, internal S
• 240 GB SSD SATA in removable T
drive bay; front
1)
For an up-to-date overview, see the SIMATIC IPC online configurator at:
http://www.siemens.com/ipc-configurator
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
2
• Windows 7 Ultimate, 32-bit MUI A • 4 GB DDR3 1600 DIMM 6ES7648-2AJ60-0MA0
(Eng, Ger, Fr, It, Sp), SP1 • 8 GB DDR3 1600 DIMM 6ES7648-2AJ70-0MA0
• Windows 7 Ultimate, 64-bit MUI B • 8 GB DDR3 1600 DIMM, ECC 6ES7648-2AJ70-1MA0
(Eng, Ger, Fr, It, Sp), SP1
• Windows Server 2008 R2 F Hardware accessories
Standard Edition incl. 5 Clients, Rack unit for low-profile 6ES7648-0EG01-1BA0
64-bit, MUI (Eng, Ger, Fr, It, Sp), removable drive bay
SP1
For 3.5" hard drive (SATA/SAS) and
• Without operating system X 2.5" SSD (SATA), without drive
Expansions (software) / Security Filter mats A5E02396171
• SIMATIC IPC DiagMonitor A for SIMATIC IPC647D (packing unit:
software V4.4 included 10 units)
• SIMATIC IPC Image Creator B Adapter cable
software V3.3 included
• Adapter cable DisplayPort to 6ES7648-3AF00-0XA0
• SIMATIC IPC DiagMonitor 4.4 and C DVI-D for onboard graphics
Image Creator Software 3.3
included • Adapter cable DisplayPort to 6ES7648-3AG00-0XA0
VGA for onboard graphics
• Without software X
Power cable, straight, 3 m long
• Without expansions (software) / Y
TPM (not for China and Russia) • Austria, Belgium, Finland, France, 6ES7900-0AA00-0XA0
Germany, Netherlands, Spain,
Power supply, Sweden
country-specific cable • United Kingdom 6ES7900-0BA00-0XA0
• 110 / 240 V industrial 0 • Switzerland 6ES7900-0CA00-0XA0
power supply unit with NAMUR; • USA 6ES7900-0DA00-0XA0
power cable for Europe
• Italy 6ES7900-0EA00-0XA0
• 110 / 240 V industrial 1
power supply unit with NAMUR; • China 6ES7900-0FA00-0XA0
power cable for United Kingdom USB retainer 6ES7648-1AA00-0XK0
• 110 / 240 V industrial 2 for interlocking the internal USB
power supply unit with NAMUR; port
power cable for Switzerland
• 110 / 240 V industrial 3 Expansion components See catalog ST 80 / ST PC
power supply unit with NAMUR;
power cable for USA
• 110 / 240 V industrial 4
power supply unit with NAMUR;
power cable for Italy
• 110 / 240 V industrial 5
power supply unit with NAMUR;
power cable for China
• 2 x 110 / 240 V redundant 6
power supply;
without power cable
1) For an up-to-date overview, see the SIMATIC IPC online configurator at: Note:
http://www.siemens.com/ipc-configurator
Software Packages with SIMATIC WinCC flexible,
WinCC RT Advanced, SIMATIC WinCC,
and SIMATIC WinAC RTX (F) can be ordered together
with the SIMATIC IPC at a price advantage. More information
under "Embedded Bundles / Packages for industrial PCs".
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC847D
• RAID5 configuration: Striping with parity on three SATA hard
■ Overview disks for increased memory capacity in hot-removable drive
bays, with additional hot spare hard disk option
• "Hot swap" HDD in removable drive bay in RAID configura-
tions (replacement of hard disk during operation)
• "Hot spare" HDD in removable drive bay in RAID configura-
tions (the rebuild process on the "hot spare" hard disk starts up 2
automatically)
• Fast identification and replacement of the hard disk in the
event of a fault by means of HDD alarm LEDs for RAID config-
urations and unambiguous numbering
• Status display (front LEDs) for Ethernet and PROFIBUS or
PROFINET; alarm indication for fan, temperature, watchdog
and hard disks in RAID1/5 configurations
• Efficient self-diagnostics per SIMATIC PC DiagBased or
DiagMonitor software (optional)
• Remote control and maintenance with iAMT 9.0 (Intel® Active
Management Technology)
• Solid-state drive (SSD) in multi-level cell (MLC) architecture
IPC 847D front view and ECC memory (optional)
• Redundant power supply with "hot swap" functionality
The SIMATIC IPC847D is an extremely robust, high-performance (replacement of power supply module during operation)
industrial PC in 19" rack design (4 U) with excellent industrial • Redundant Gbit LAN connections (teaming capability)
functionality.
• Securing of the replaceable components at the front
It offers: (e.g. USB software dongle) against unauthorized access by
• Maximum expandability means of a lockable door
• Extreme ruggedness • Locked fan cover: Filter mat and front fan can only be
• 4th generation Intel® Core™ i technology replaced when front door is open
• The enclosure cover can only be opened if the front door
■ Benefits is open
• Secure internal USB slot in device for software dongle,
Maximum industrial compatibility and compactness for example
for 24-hour use in an industrial environment • Service-friendly device design (modifications, service)
• Maximum processor performance (in maximum configuration) e.g. filter replacement or front fan replacement without tools
without loss of power (throttling) at ambient temperatures of
up to 50 °C Cost reductions through high investment security
• Distinct product design with new front design and fully- • Platform with long-term stability and embedded Intel compo-
coated, dirt-resistant surfaces nents
• All-metal housing with high EMC for use in industrial • Availability of 3 to 6 years, guaranteed availability of spare
environment parts for 5 years
• Suitable for installing in space-saving control cabinets only • System-tested with SIMATIC components
500 mm deep • Certification for worldwide marketing (cULus)
• Dust protection thanks to overpressure ventilation concept • Support for legacy interfaces (PS/2, COM, LPT)
with fan on the front and dust filter • Installation compatible for many device generations
• Special hard disk holders and card retainers for protection • Worldwide service and support
against vibration and shock
Reduced costs due to time savings for commissioning,
High productivity thanks to faster data processing operation and servicing
• 4th generation Intel® processors: Xeon, Core i5 or Core i3 with • High degree of flexibility and expandability thanks to
turbo-boost, hyper-threading and virtualization technology integrated interfaces and up to 11 slots (PCI and PCI-Express)
• Graphics controller (HD graphics 4600) integrated in the • Preinstalled and activated operating system
processor for exceptionally high graphics performance
• Fast restoration of the delivery status of the HDD thanks to
• Maximum performance (e.g. Intel C226 Express chipset, restore DVD
DDR3 memory with the support of dual-channel technology)
• Low noise output thanks to controlled fan
• High data transfer rates (e.g. PCI-Express technology:
Gen 2 and Gen 3, USB 3.0 SuperSpeed (500 Mbit/s), • Universal implementation as an industrial workstation or
SATA III/6 Gbit/s) server
• PROFIBUS or PROFINET interface and RAID1/5 controller
Reduction in downtimes through high system availability onboard (optional)
• Secure 24-hour operation (high MTBF, variable-speed fan) • 2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with
at ambient temperature up to 50° C teaming capability)
• High data security thanks to RAID configurations • Flexible applications in many different positions with
(RAID controller onboard) telescopic rails or as tower industrial PC
• RAID1 configuration: Redundant data storage on two SATA • Remote maintenance with iAMT technology and SIMATIC IPC
hard disks, also in hot-removable drive bays and with Remote Manager software
additional SSD (for operating system) or hot spare hard disk
option
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC847D
■ Technical specifications
SIMATIC IPC847D SIMATIC IPC847D
General features Drives
Design 19" rack, 4 U, externally painted Serial ATA 3.5" hard disks (HDD) Mounted internally on the permanent
2 Processor • Intel® Xeon™ E3-1268L v3
4C/8T, 2.3 (3.3) GHz, 8 MB cache,
with NCQ technology and hard disk support:
serial ATA 2.5" solid-state drive (SSD) • 1 x 500 GB HDD
with MLC technology • 1 x 240 GB SSD
turbo-boost 2.0, Extended Memory
64 (EM64) and virtualization Can be installed in internal shock and
technology (VT-x/-d), iAMT 9.0 vibration-damped drive cage
• Intel® Core™ i5-4570TE (optional)
2C/4T, 2.7 (3.3) GHz, 4 MB cache, • 1 x 500 GB HDD
turbo-boost 2.0, Extended Memory • 1 x 1 TB HDD
64 (EM64) and virtualization • 2 x 1 TB HDD
technology (VT-x/-d), iAMT 9.0 • RAID13), 1 TB
• Intel® Core™ i3-4330TE (2 x 1 TB HDD, mirror disks)
2C/4T, 2.4 GHz, 4 MB cache, • RAID13), 1 TB
Extended Memory 64 (EM64) and (2 x 1 TB HDD, mirror disks) +
virtualization technology (VT-x) 1 x 240 GB SSD (for operating
system) in removable drive bay
Chipset Intel C226
Installed on the front in the low-profile
Main memory • From 2 GB DDR3 1600 SDRAM removable drive bay
• Dual channel support (hot swapping in RAID configura-
• 4 DIMM base tions):
• Expandable up to 32 GB 1) • 1 x 500 GB HDD
• ECC memory (optional) • 1 x 1 TB HDD
• 2 x 1 TB HDD
Spare slots for expansions More PCI slots • 1 x 240 GB SSD
(all 312 mm long) (7 PCI, 4 PCI-Express): • RAID13), 1 TB
• 7 x PCI (2 x 1 TB HDD, mirror disks)
• 1 x PCI-Express x16 (16 lanes) • RAID13), 1 TB
Gen 3 (2 x 1 TB HDD, mirror disks) +
• 3 x PCI-Express x4 (1 lane) • 1 x 1 TB HDD as hot spare
Gen 2 • RAID13), 1 TB
or (2 x 1 TB HDD, mirror disks) +
1 x 240 GB SSD
More PCI-Express slots
(for operating system)
(8 PCI-Express, 3 PCI):
• RAID53), 2 TB
• 3 x PCI
(3 x 1 TB HDD, striping with parity)
• 1 x PCI-Express x16 (8 lanes) Gen 3
• RAID53), 2 TB
• 2 x PCI-Express x16 (4 lanes) Gen 3
(3 x 1 TB HDD, striping with parity) +
• 2 x PCI-Express x16 (4 lanes) Gen 2
1 x 1 TB HDD as hot spare
• 3 x PCI-Express x4 (4 lane) Gen 2
DVD+/-R/RW, slim, SATA • 8 x 8 x 6 x (DVD media)
Graphics Onboard Intel HD 4600 graphics con-
• 24 x 10 x 16 x (CD media)
troller integrated into the processor
Dynamic Video Memory up to 1.7 GB Slots for drives Front:
Up to 3840 x 2160 pixels at 60 Hz • 3 x 5.25" / 4 x low-profile removable
image refresh rate and 32-bit colors drive bay
PCI Express graphics card (Dual • 1 x slim (ODD)
Head: 2 x VGA or 2 x DVI-D) in the Internal:
PCIe x16 slot (optional) • 2 x 3.5"
512 MB, up to 2048 x 1536 pixels at or
60 Hz image refresh rate and 32- • 2 x 3.5" (in the optional, vibration-
bit colors damping drive cage)
Operating system • without Interfaces
• Preinstalled and activated / sup-
plied on restore DVD PROFINET 3x RJ45 (CP 1616-compatible),
• Windows 7 Ultimate MUI, 32/64-bit optional
• Windows Server 2008 R2 incl.
PROFIBUS/MPI 12 Mbit/s (isolated, compatible
5 client MUI, 64-bit
with CP 5622), optional
MUI: Multi-language User Interface;
5 languages (English, French, Ethernet 2 x 10/100/1000 Mbit/s
German, Italian, Spanish) (RJ45, teaming-capable)
• Project-specific on request USB 3.0 • 1 x front (high current)
• Linux 2) • 2 x rear (high current)
• Other • 1 x internal (high current), e.g. for
Power supply • 100 ... 240 V AC, 50 ... 60 Hz USB dongle
with bridging of temporary power USB 2.0 • 1 x front (high current),
failures in accordance with NAMUR: can be used with door closed
max. 20 ms at 0.85 % rated voltage • 2 x rear; (high current)
• Redundant 100 ... 240 V AC,
50 ... 60 Hz Serial • 9-pin COM1 (V.24)
• 9-pin COM2 (V.24) (optional)
Parallel • LPT1 (optional)
VGA Optionally via adapter cable
DVI-I •1x
DisplayPort V1.2 •2x
Keyboard PS/2
Mouse PS/2
Audio 1 x Line Out; 1 x Micro
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC847D
2
software drives in optional, internal drive cage:
• Half-sine: 50 m/s2, 30 ms (approx.
Temperature • Overshoot/undershoot of permissi- 5 g), 100 shocks per axis
ble operating temperature range • Permanently installed internal hard
• Messages can be evaluated by the disk drives: 30 m/s2, 30 ms
application program (approx. 3 g)
Fan • Speed monitoring Note: There are limitations when
• 2 x enclosure fans DVD+/-RW and HDD are operated in
• 1 x fan power supply a removable drive bay
Watchdog • Monitoring of program execution Electromagnetic compatibility
• Monitoring time can be parameter- (EMC)
ized in software
• Restart can be parameterized in the Emitted interference (AC) • EN 61000-6-3, FCC Class A
event of a fault • EN 61000-6-4;
• Messages can be evaluated by the • CISPR 22, EN 55022 Class B
application program • EN 61000-3-2 Class D,
EN 61000-3-3
Monitoring functions via the network SIMATIC PC DiagMonitor (optional)
Immunity to conducted interference • ± 2 kV (IEC 61000-4-4, burst)
Remote monitoring capability for: on the supply lines • ± 1 kV
• Watchdog (IEC 61000-4-5, symm. surge)
• Temperature • ± 2 kV
• Fan speed (IEC 61000-4-5, asymm. surge)
• Hard disk monitoring (SMART)
• System/Ethernet monitoring Noise immunity on signal lines • ± 1 kV (IEC 61000-4-4, burst,
(Heartbeat) length < 30 m)
• ± 2 kV (IEC 61000-4-4, symm.
Communication: surge, length > 30 m)
• Ethernet interface (SNMP protocol) • ± 2 kV (IEC 61000-4-5, asymm.
• OPC for integration in SIMATIC surge, length > 30 m)
software
• Configuration of client/server Immunity to static discharge • ± 6 kV, contact discharge
architectures (IEC 61000-4-2)
• Structure of log files • ± 8 kV, air discharge
(IEC 61000-4-2)
Front LEDs • POWER (internal power supply unit,
PC switched on) Immunity to high radio frequency • 10 V/m, 80 to 1000 MHz and
• ETHERNET1 (Ethernet status, interference 1.4 to 2 GHz, 80% AM
"Heartbeat") (according to IEC 61000-4-3)
• ETHERNET2 (Ethernet status, • 3 V/m, 2 to 2.7 GHz, 80% AM
"Heartbeat") (to IEC 61000-4-3)
• PN / MPI/DP (PROFINET/PROFIBUS • 10 V, 10 kHz to 80 MHz, 80% AM
status) (according to IEC 61000-4-6)
• WATCHDOG (ready/fault indication)
• TEMP (temperature status) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
• FAN (fan speed monitoring) Ambient temperature during 5 ... 50 °C
• HDD0 ALARM 4) operation
• HDD1 ALARM 4) Note: Limitations for operation of
• HDD2 ALARM 4) DVD+/-RW
• HDD (access to hard disk) / HDD3 Relative humidity during operation 5 ... 80 % at 25 °C (no condensation)
ALARM 4)
Approvals and safety regulations
Ambient conditions
Safety regulations • IEC 60950-1
Degree of protection IP41 at the front, IP20 at the rear • EN 60950-1
acc. to EN 60529 • UL 60950-1
Dust protection With front door closed: G2 EN 779, • CSA C22.2 No 60950-1-07
99 % of particles > 0.5 mm are held Approvals cULus 60950-1 Second Edition, KCC
back
CE mark • Emitted interference: EN 61000-6-3:
Protection class Protection class I 2007 +A1:2011
according to IEC 61140 • Noise immunity: EN 61000-6-2:2005
Vibration load during operation DIN EN 60068-2-6, 10 cycles Dimensions and weights
Internal mounting of the hard disk
Installation dimensions 430 x 177 x 448
drives in optional, internal drive cage:
(W x H x D) in mm
• 10 ... 58 Hz: 0.0375 mm;
• 58 ... 500 Hz: 5 m/s2 (approx. 0.5 g) 1)
Memory information: in order to use a memory with more than 4 GB,
Permanently installed internal hard a 64-bit operating system is required. In the case of configurations with at
disk drives: least 4 GB, the visible memory can be reduced to about 3.5 GB or less
• 10 ... 58 Hz: 0.019 mm; (with 32-bit operating systems).
• 58 ... 500 Hz: 3 m/s2 (approx. 0.3 g) 2)
Suitable for specific LINUX versions in accordance with the specifications
Note: of the Siemens manufacturer's declaration "Suitable for LINUX"
There are limitations when DVD+/-RW (LINUX is a trademark of Linus Torvalds).
and HDD are operated in a remov- 3)
SATA RAID controller on board in Intel chipset
able drive bay 4)
Hard disk alarm in conjunction with RAID and monitoring software
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC.
Installation can only be performed on these SIMATIC systems
in accordance with Microsoft OEM licensing regulations.
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC847D
2
Interfaces: 2 x GBIT LAN (RJ45); striping with parity) in removable
1 x DVI-I; 2 x DisplayPort; drive bay, hot swap + 1 TB SATA
1 x COM; 2 x PS/2; Audio; HDD as hot spare in removable
2 x USB 3.0, 2 x USB 2.0 at rear; drive bay, front;
1 x USB 3.0, 1 x USB 2.0 at front, • 240 GB SSD SATA, internal M
1 x USB 3.0 internal;
Temperature and fan monitoring, • 240 GB SSD SATA in removable N
watchdog, card retainer; drive bay; front
Processor/motherboard • RAID1, 1 TB (2 x 1 TB HDD SATA, P
mirror disks), internal
• Core i3-4330TE D (0.5 g vibration, 5 g shock) +
(2C/4T, 2.4 GHz, 4 MB cache); 240 GByte SSD SATA
mainboard without fieldbus (for operating system)
• Core i3-4330TE (2C/4T, 2.4 GHz, E in removable drive bay
4 MB cache, VT-x); • RAID1, 1 TB (2 x 1 TB HDD, SATA, Q
mainboard with PROFIBUS/MPI mirror disks) in removable drive
(CP 5622-compatible) bay, hot swap + 1 TB HDD SATA
• Core i3-4330TE F as hot spare in removable drive
(2C/4T, 2.4 GHz, 4 MB cache); bay, front;
mainboard with PROFINET • RAID1, 1 TB (2 x 1 TB HDD SATA, R
(3 x RJ45, CP 1616-compatible) mirror disks) i+ 240 GByte SSD
• Core i5-4570TE G SATA (for operating system)
(2C/4T, 2.7 (3.3) GHz, in removable drive bay, hot-swap;
4 MB Cache, TB, VT-d, AMT); front
mainboard without fieldbus Memory configuration
• Core i5-4570TE H • 2 GB DDR3 SDRAM (1 x 2 GB), 1
(2C/4T, 2.7 (3.3) GHz, 4 MB single channel
cache, TB, VT-x, VT-d, AMT); • 4 GB DDR3 SDRAM (2 x 2 GB), 2
mainboard with PROFIBUS/MPI dual channel
(CP 5622-compatible)
• 8 GB DDR3 SDRAM (2 x 4 GB), 3
• Core i5-4570TE J dual channel
(2C/4T, 2.7 (3.3) GHz,
• 16 GB DDR3 SDRAM (2 x 8 GB), 4
4 MB cache, TB, VT-d, AMT);
dual channel
mainboard with PROFINET
(3 x RJ45, CP 161-compatible) • 32 GB DDR3 SDRAM (4 x 8 GB), 5
dual channel
• Xeon E3-1268L v3 K
(4C/8T, 2.3 (3.3) GHz, • 8 GB DDR3 SDRAM, (2 x 4 GB), 6
8 MB cache, TB, VT-d, AMT); ECC, dual channel
mainboard without fieldbus • 16 GB DDR3 SDRAM, (2 x 8 GB), 7
L ECC, dual channel
• Xeon E3-1268L v3
• 32 GB DDR3 SDRAM, (4 x 8 GB), 8
(4C/8T, 2.3 (3.3) GHz,
ECC, dual channel
8 MB cache, TB, VT-x, VT-d, AMT);
mainboard with PROFIBUS/MPI Bus module / swap media
(CP 5622-compatible) • Bus module 11-slot: 0
• Xeon E3-1268L v3 M 7 x PCI, 3 x PCIe x4, 1 x PCIe x16;
(4C/8T, 2.3 (3.3) GHz, 8 MB without swap media
cache, TB, VT-d, AMT); • Bus module 11-slot: 1
mainboard with PROFINET 3 x PCI, 3 x PCIe x4, 5 x PCIe x16;
(3 x RJ45, CP 1616-compatible) without swap media
Drives • Bus module 11-slot: 2
• 500 GB HDD SATA, internal A 7 x PCI, 3 x PCIe x4, 1 x PCIe x16;
(0.3 g vibration, 3 g shock) DVD±RW (slim)
• 500 GB HDD SATA, internal B • Bus module 11-slot: 3
(0.5 g vibration, 5 g shock) 3 x PCI, 3 x PCIe x4, 5 x PCIe x16;
DVD±RW (slim)
• 1 TB HDD SATA, internal C
(0.5 g vibration, 5 g shock) Expansion hardware
• 2 x 1 TB HDD SATA, internal D • Without expansions (hardware), 0
(0.5 g vibration, 5 g shock) onboard graphics;
• RAID1, 1 TB (2 x 1 TB HDD SATA, E • Without expansions (hardware), 1
mirror disks), internal onboard graphics, DVI-I adapter
(0.5 g vibration, 5 g shock) cable, VGA-compliant for onboard
• 500 GB HDD SATA in removable F graphics;
drive bay; front • Serial (COM2) + parallel 2
• 1 TB HDD SATA in removable G (LPT, 1 slot reserved), onboard
drive bay; front graphics;
• 2 x 1 TB HDD SAT in removable H • Serial (COM2) + parallel 3
drive bay; front (LPT, 1 slot reserved), onboard
• RAID1, 1 TB (2 x 1 TB HDD SATA, J graphics; DVI-I adapter cable,
mirror disks) in removable drive VGA-compliant for onboard
bay, hot-swappable, front; graphics;
• RAID5, 2 TB (3 x 1 TB HDD, SATA, K • Serial (COM2) + Parallel 4
striping with parity) in removable (LPT, 1 slot reserved) +
drive bay, hot-swappable, front PCIe x16 Graphics Card (Dual-
Head: 2 x VGA or 2 x DVI-D),
512 MB, (1 slot reserved);
1) For an up-to-date overview, see the SIMATIC IPC online configurator at:
http://www.siemens.com/ipc-configurator
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC847D
2
• Windows 7 Ultimate, 32-bit MUI A • 4 GB DDR3 1600 DIMM 6ES7648-2AJ60-0MA0
(Eng, Ger, Fr, It, Sp), SP1 • 8 GB DDR3 1600 DIMM 6ES7648-2AJ70-0MA0
• Windows 7 Ultimate, 64-bit MUI B • 8 GB DDR3 1600 DIMM, ECC 6ES7648-2AJ70-1MA0
(Eng, Ger, Fr, It, Sp), SP1
• Windows Server 2008 R2 Stan- Hardware accessories
F
dard Edition incl. 5 Clients, 64-bit, Rack unit for low-profile remov- 6ES7648-0EG01-1BA0
MUI (Eng, Ger, Fr, It, Sp), SP1 able drive bay
• Without operating system X For 3.5" hard drive (SATA/SAS) and
2.5" SSD (SATA), without drive
Expansions (software) / Security
• SIMATIC IPC DiagMonitor A Filter mats A5E01064980
software V4.4 included for SIMATIC IPC847D
• SIMATIC IPC Image Creator B (packing unit: 10 units)
software V3.3 included Adapter cable
• SIMATIC IPC DiagMonitor 4.4 and C • DisplayPort to DVI-D 6ES7648-3AF00-0XA0
Image Creator Software 3.3 for onboard graphics
included
• DisplayPort to VGA 6ES7648-3AG00-0XA0
• Without software (software) X for onboard graphics
• Without expansions (software) / Y
TPM (not for China and Russia) Power cable, straight, 3 m long
• Austria, Belgium, Finland, France, 6ES7900-0AA00-0XA0
Power supply, Germany, Netherlands, Spain,
country-specific cable Sweden
• 110 / 240 V industrial 0 • United Kingdom 6ES7900-0BA00-0XA0
power supply unit with NAMUR; • Switzerland 6ES7900-0CA00-0XA0
power cable for Europe
• USA 6ES7900-0DA00-0XA0
• 110 / 240 V industrial 1
power supply unit with NAMUR; • Italy 6ES7900-0EA00-0XA0
power cable for United Kingdom • China 6ES7900-0FA00-0XA0
• 110 / 240 V industrial 2 Tower Kit 6ES7648-1AA00-0XD0
power supply unit with NAMUR; for converting the computer
power cable for Switzerland into an industrial tower PC
• 110 / 240 V industrial 3
power supply unit with NAMUR; USB retainer 6ES7648-1AA00-0XK0
power cable for USA for interlocking the internal USB
• 110 / 240 V industrial 4 port
power supply unit with NAMUR; Expansion components See catalog ST 80 / ST PC
power cable for Italy
• 110 / 240 V industrial 5
power supply unit with NAMUR;
power cable for China
• 2 x 110 / 240 V redundant 6
power supply;
without power cable
1)
For an up-to-date overview, see the SIMATIC IPC online configurator at: Note:
http://www.siemens.com/ipc-configurator
Software Packages with SIMATIC WinCC flexible,
WinCC RT Advanced, SIMATIC WinCC,
and SIMATIC WinAC RTX (F) can be ordered together
with the SIMATIC IPC at a price advantage. More information
under "Embedded Bundles / Packages for industrial PCs".
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
Box PC
General data
■ Overview
SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
2
• Maximum compactness with approx. 1 liter enclosure volume
with integrated industrial power supply for minimum space
requirements in the control cabinet
• Maximum flexibility thanks four mounting options and inter-
faces on one side suitable for every installation situation
• Optimum variety of interfaces due to a large number of
integrated interfaces such as selectable serial ports (RS 232/
RS 485/CAN) and 2 x teaming-capable Gigabit Ethernet
• Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
• Further device options for optimum adaptation to the
application with additional PCIe slot or RS 232 interfaces
or digital I/O
SIMATIC IPC427 (Microbox PC):
SIMATIC Box PC family The powerful embedded IPC – maintenance-free with
versatile configuration
SIMATIC Box PCs provide mechanical engineers, plant • Fan-free operation
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applica- • High performance with maximum compactness and
tions. ruggedness for direct installation in the machine
• Optimized for embedded applications
The following device classes are available for various
requirements: • Flexibility expandable using one or two PCIe I/O cards
(optional)
• SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and dust- • Flexible installation options due to DIN rail/wall/front upright
proof with versatile mounting mounting, even outside a control cabinet
• SIMATIC IPC427 (Microbox PC): • NVRAM for retentive data storage (optional)
The powerful embedded IPC – maintenance-free with SIMATIC IPC627/IPC827 (Box PC):
versatile configuration The high-end IPC – with maximum performance, functional
• SIMATIC IPC627/IPC827 (Box PC): scope, and expansion capability
The high-end IPC – with maximum performance, functional • Maximum system performance for complex measuring,
scope, and expansion capability control and visualization tasks
Shared industrial functionality: • High flexibility with expansion slots and integral interfaces
• Extreme compactness • Flexible, space-saving installation with mounting brackets or
• Certification for global marketing portrait assembly kits
• System-tested with SIMATIC components • Rugged design for direct installation in the machine
• High vibration/shock load during operation • RAID1 controller onboard
• Wide operational temperature range • Maximum processor performance up to ambient temperature
of 55 °C
• Robust data storage with CompactFlash/CFast or Solid-State
Drive (SSD) • High system availability
• Integrated PROFIBUS or PROFIBUS/MPI interface (optional) • Battery-backed SRAM as memory for WinAC data
• Varied mounting possibilities for flexibility with installation • 4 signaling LEDs
• Designed for 24-hour continuous operation
• Integrated parameterizable monitoring functions
(temperature, fan, watchdog)
• High service friendliness
• Operating system preinstalled and activated for fast startup
• Motherboard developed and manufactured by Siemens
• Availability for 3 to 6 years
• Repairs and spare parts service for 5 years
• High component/design continuity
• Installation and software compatible with predecessor model
• Long-term availability of PC components from the Intel
embedded line
PROFINET/Industrial Ethernet
Industrial PC
Box PC
General data
■ Benefits
Compact dimensions Integrated interfaces
The SIMATIC IPC227D is a particularly compact and energy- On Box PCs, all interfaces are located on one side. Box PCs
efficient PC in the Nano format. The heart of the Nanobox PC can be interfaced with the control/cell level via onboard Ethernet
with particularly many mounting options are high-performance
Intel Atom processors of the latest generation.
interfaces and communicate in the field via an integrated
PROFIBUS interface, which is available as an option. External 2
monitors or displays can be connected via a VGA or DVI-I
The SIMATIC IPC427 (Microbox PC) is an ultra-compact and interface.
rugged device for DIN rail mounting, portrait or wall mounting,
and for use in the machine: mounting depth from 47 mm. Flexibility
With a maximum mounting depth of 100 mm (80 mm without Especially the SIMATIC IPC827 with its 5 free PC slots offers
DVD drive), the SIMATIC IPC627 (Box PC) can be used even in many expansion options. All Box PCs have CE certification for
the smallest of spaces. In addition, space-saving portrait mount- use in industrial applications and domestic/commercial applica-
ing is possible with the SIMATIC Box IPC627/IPC827. tions and can therefore be used in building automation or public
installations in addition to industrial applications.
Rugged design
All designs aim to achieve maximum safety in the case of vibra- Continuity
tion and shock loads. For example, a special vibration-absorb- Thanks to motherboards developed and manufactured in-
ing suspension of the hard disk ensures operational reliability, house, the SIMATIC Box PCs offer very high continuity and
even at very high mechanical loads. A flash drive slot, which is security of investment. The SIMATIC Box PC models can
easily accessible from outside, or the solid-state drive (SSD) in normally be ordered for a period of three years and spare parts
the single level cell (SLC) architecture, which is particularly are obtainable for at least 5 years after active marketing is
suitable for industrial applications, is available for setting up low- concluded.
maintenance, fault-tolerant, diskless systems. Thanks to its fan-
free design and use of CompactFlash cards, the Microbox PC System availability
and the new Nanobox PC are especially suitable for mainte- SIMATIC Box PCs can be ordered in custom configurations and
nance-free 24-hour continuous operation. are supplied ready for use. The high system availability by
Service-friendly device design design can be further extended by means of additional data
backup options (e.g. RAID system, SIMATIC IPC Image &
The Box PC can simply be folded out for speedy component Partition Creator) and efficient software for self-diagnostics
replacement. The inside of the device is easily accessible for (SIMATIC IPC DiagMonitor).
future expansions.
■ Technical specifications
SIMATIC IPC227D SIMATIC IPC427D SIMATIC IPC627D SIMATIC IPC827D
(Nanobox PC) (Microbox PC) (Box PC) (Box PC)
Design
Rail or wall mounting • • - -
Wall or portrait mounting • Also: Side mounting • • •
General features
Processor • Intel Atom E620 600 MHz • Intel Core i7-3517UE, • Intel Xeon processor • Intel Xeon processor
• Intel Atom E640 1.0 GHz 1.7 GHz, 4 MB SLC E3-1268L v3 (4 cores, E3-1268L v3 (4 cores,
• Intel Atom E660 1.3 GHz • Intel Core i3-3217UE, 8 threads, 2.3 (3.3) GHz, 8 threads, 2.3 (3.3) GHz,
1.6 GHz, 3 MB SLC 8 MB cache, VT-d, AMT) 8 MB cache, VT-d, AMT)
• Intel Celeron 827E • Intel Core i3-4330TE pro- • Intel Core i3-4330TE
1.4 GHz, 1.5 MB SLC cessor (2 cores, 4 threads, (2 cores, 4 threads,
2.4 GHz, 4 MB cache, VT-x) 2.4 GHz, 4 MB cache, VT-x)
• Intel Celeron G1820TE • Intel Celeron G1820TE
(2C/2T, 2.2 GHz, (2C/2T, 2.2 GHz,
2 MB cache) 2 MB cache)
Main memory 512 MB, 1 GB, 2 GB 1 GB, 2 GB, 4 GB, 8 GB 2 GB, expandable 2 GB, expandable
up to 16 GB, optional ECC up to 16 GB, optional ECC
Static RAM 512 KB 512 KB 2 MB 2 MB
Free slots for expansions 1 x PCIe Up to 2 x PCIe 2 x PCI or 2 x PCI (240 mm)
with PCIe enclosure option (enclosure option) 1 x PCIe x16 / 1 x PCI 1 x PCI (185 mm)
2 x PCIe (x16/x4) 2 x PCI-Express x16 / x4
(185 mm)
Graphics Onboard Onboard Onboard Onboard
PROFINET/Industrial Ethernet
Industrial PC
Box PC
General data
2 without
Preinstalled and activated / supplied
•
• Windows Embedded
• • •
• Windows 7 Ultimate 32-bit • Windows 7 Ultimate 32-bit • Windows 7 Ultimate 32-bit
on restore CD Standard 2009 MUI MUI MUI
(CF card 2 GB, SSD, • Windows 7 Ultimate 64-bit • Windows 7 Ultimate 64-bit • Windows 7 Ultimate 64-bit
hard disk) MUI MUI MUI
• Windows XP Professional • Windows Embedded
MUI (SSD, hard disk) Standard 7, 32-bit
• Windows Embedded (CFast >= 4 GB, SSD,
Standard 7, 32-bit hard disk)
(CF card 4 GB, SSD, • Windows Embedded
hard disk) Standard 7 Professional,
• Windows 7 Ultimate MUI, 32-bit, MUI (CFast >=
32-bit (SSD, hard disk) 8 GB, SSD, hard disk)
Order separately RMOS3 V3.50 RMOS3 V3.50 - -
Project-specific on request • Linux 1) • Linux 1) • Linux 1) • Linux 1)
• Other • Other • Other • Other
Interfaces
PROFINET onboard - 3 x RJ45 3 x RJ45 3 x RJ45
(CP 1616 compatible) (CP 1616 compatible) (CP 1616 compatible)
onboard, optional onboard, optional onboard, optional
PROFIBUS/MPI - 12 Mbps 12 Mbps 12 Mbps
(CP 5622-compatible), (CP 5622-compatible) (CP 5622-compatible)
optional onboard, optional onboard, optional
Ethernet 2 x 10/100/1000 Mbps 2 x 10/100/1000 Mbps 2 x 10/100/1000 Mbps 2 x 10/100/1000 Mbps
USB 4 x USB 2.0 - 4 x USB 3.0 4 x USB 3.0
Graphics 1 x DVI-D • 1 x DVI-I (DVI and VGA) • 1 x DVI-I (DVI or VGA) • 1 x DVI-I (DVI and VGA)
• 1 x DisplayPort • 1 x DisplayPort • 1 x DisplayPort
Drives
Hard disks 1 x 2.5" (optional) 1 x 2.5" (optional) • 1 x 3.5" • 1 x 3.5"
• 2 x 2.5" • 2 x 2.5"
• RAID1/2 x 2.5" • RAID1/2 x 2.5"
Solid-state drive 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional)
FlashDrive 1 x CF externally accessible • 1 x CFast externally - -
accessible
• 1 x CFast internal,
in place of HDD, SSD
(optional)
Optical drives - - DVD R/W DVD R/W
Ambient conditions
Vibration/shock load 1 g / 15 g (with FlashDrive) 1 g / 15 g (with FlashDrive) 1g/5g 1g/5g
during operation
Ambient temperature 0 °C … 50 °C With maximum configuration: With maximum configuration: With maximum configuration:
during operation (with FlashDrive) 0 ... 50/55 ºC 5 ... 45 °C 5 ... 45 °C
0 °C … 40 °C (with FlashDrive) 5 ... 50/55 °C (with 20/10 W 5 ... 50/55 °C (with 20/10 W
(with hard disk) 5 ... 40 ºC (with hard disk) load on USB, PCI(e) bus) load on USB, PCI(e) bus)
• Available
- Not available
1)
Suitable for specific Linux versions in accordance with the specifications of
the Siemens manufacturer's declaration "Suitable for Linux", see
www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvalds).
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded
from the Internet:
http://www.siemens.com/simatic/printmaterial
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC227D
■ Overview ■ Benefits
• Flexible installation (rail, wall, portrait, side mounting);
all mounting positions are allowed
• Minimum space requirements (installation space of approx.
1 liter or more; all interfaces on one side, integrated industrial
power supply) 2
• Up to 50 °C ambient temperature; dust protection due to
closed enclosure
• LED for efficient self-diagnostics (e.g. using WinAC:
Run/Stop, Error, Maintenance); optimized for headless
operation
• Device options for optimum adaptation to the application
(optional)
- Simple expansion by means of a PCIe slot or
- three additional RS232 interfaces or
- four additional digital inputs and outputs each, 24 V DC
High-performance data processing at low power consumption
• Intel Atom technology of the Power-Optimized family E6xx
• Power consumption from 8 W (low waste heat in protective
SIMATIC IPC227D (Nanobox PC): enclosure/control cabinet)
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting • Wake-on-LAN for remote-controlled switching between
standby and active state
• Maximum compactness with approx. 1 liter enclosure volume
or more with integrated industrial power supply for minimum • Support of Sleep States/SpeedStep (dynamic power
space requirements in the control cabinet adaptation depending on the required computing perfor-
mance)
• Maximum flexibility thanks four mounting options and inter-
faces on one side suitable for every installation situation • Intel VT-x technology for virtualization
• Optimum variety of interfaces due to a large number of High degree of industrial functionality and flexibility
integrated interfaces such as a selectable serial port for implementing the embedded solution
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN • Flexible memory concepts: CompactFlash or more,
• Maximum industrial functionality due to closed enclosure for Solid-State Drive, or hard drive
optimum dust protection and non-volatile retentive memory • 2 Gbit Ethernet (teaming-capable); PROFINET with
• Further device options for optimum adaptation to the RT functionality (via Standard Ethernet)
application with additional PCIe slot or RS 232 interfaces or • 4 high-speed USB 2.0 ports
digital I/O
• 1 RS232; alternatively as: RS485 or CAN (optional)
• Ready-to-run embedded bundles with WinAC RTX2010 (F)
and/or WinCC RT Advanced (optional)
• 512 KB retentive memory (MRAM), of which 128 KB can be
written to within the buffer time (optional)
• Embedded and standard operating systems for selection:
Windows Embedded Standard 2009 and Windows XP Prof.
MUI; Windows Embedded Standard 7 32 bit and Windows 7
MUI 32 bit
• Suited for Linux certificate for simple, secure implementation
of proprietary Linux-based solutions
High system availability in order to reduce the risk
of potential failures and maintenance costs
• Maintenance-free since there are no rotating parts (fans, HDD)
• Battery-free operation even if retentive memory option is
selected (with time-of-day synchronization over network)
• Comprehensive self-diagnostics thanks to pre-installed local
diagnostics software SIMATIC IPC DiagBase
High investment security in order to reduce engineering costs
• Long-term availability: Service & Support period of 8 – 10
years after market launch
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC227D
■ Technical specifications
6ES7647-8A...-.... 6ES7647-8A...-....
Processor Degree and class of protection
Processor Intel Atom E6x0 IP (at the front) 20
2 Drives
Hard disk CF or SSD or HD
Standards, approvals, certificates
Approval CE (industry), UL, cULus
Memory CE mark Yes
Main memory 512 MB to 2 GB KC approval Yes
Data areas and their retentivity Marine approval
retentive data area in total 512 kbyte • Germanischer Lloyd (GL) Yes
(incl. times, counters, flags), max.
• American Bureau of Shipping Yes
Interfaces (ABS)
USB port 4x USB 2.0 high speed/high current • Bureau Veritas (BV) Yes
free slots 1x PCIe x1 (optional) • Det Norske Veritas (DNV) Yes
• Lloyds Register of Shipping (LRS) Yes
Connection for keyboard/mouse USB / USB
Ambient conditions
serial interface COM1: 1 x RS232 or RS485 or CAN Operating temperature
Video interfaces • Ambient temperature during opera-
• Graphics interface DVI-D tion
- during operating phase, min. 0 °C
Industrial Ethernet
- during operating phase, max. 50 °C
• Industrial Ethernet interface 2 x Fast Ethernet
- 100 Mbps Yes Operating systems
- 1000 Mbps Yes Pre-installed operating system Yes
Monitoring functions Windows XP Prof. Yes
Temperature Yes without operating system Yes
Watchdog Yes
Status LEDs Yes
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC227D
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC427D
■ Overview ■ Benefits
High data processing speed for high productivity
• Up to Core I 7, fan-free
• DDR3 memory technology up to 8 GB
2 Maximum compactness and ruggedness
for use directly on the machine
• Low mounting depth, ambient temperature up to 55 °C
• Upright mounting as second standard mounting position
(ambient temperature 50 °C)
• Solid State Drive (SSD) (50 GB high endurance or 80 GB
standard, optional), SATA hard disk, or up to 2 CFast cards
with 16 GB
High degree of industrial functionality and flexibility
for implementing embedded solutions
• Flexible memory concepts (e.g. 2 mass storage units
possible)
• 2 x LAN 10/100/1 000 Mbit/s connections; teaming-capable
SIMATIC IPC427D (Microbox PC): • Onboard PROFIBUS or PROFINET interface (optional)
The powerful embedded IPC – maintenance-free • 4 x high-speed USB 3.0 ports; 2 serial interfaces
with versatile configuration (2nd interface is optional)
Ready-to-run, complete solutions (software is already installed • Flexible installation with mounting options
and preconfigured) for visualization and automation in (rail, wall, front upright mounting)
connection with WinCC RT Advanced and/or WinAC RTX:
• Simple expansion capability (up to 2 PCIe slots)
• Ultra-compact
• On/off switch
• Maintenance-free
• Third generation Intel Core i technology High system availability in order to reduce the risk of
potential failures and maintenance costs
• Maintenance-free since no rotating parts (fans, hard disks)
and operation without battery possible
• 512 KB NVRAM can be written by WinAC RTX
• Front LED for efficient self-diagnostics; optimized for headless
operation through special BIOS properties
• SIMATIC software system-tested
High investment security
in order to reduce engineering costs
• Long-term availability: Service and support period of 8 to 10
years after market launch
• Installation and interface compatibility with predecessor
versions as of 2004
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC427D
■ Technical specifications
6AG4 140-.....-...0 6AG4 140-.....-...0
Supply voltage Standards, approvals, certificates
Type of supply voltage 24 V DC Approval CE, cULus (508), C-Tick
Supply voltage
Processor
24 V CE mark
KC approval
Yes
Yes
2
Processor Intel® Celeron® Processor 827E cULus Yes
(1.5MB Cache, 1.40 GHz);
Intel® Core™ i3-3217UE Processor EMC CE, EN 55022A,
(3MB Cache, 1.60 GHz); EN 61000-6-4, EN 61000-6-2
Intel® Core™ i7-3517UE Processor
(4MB Cache, up to 2.80 GHz) EN 61000-6-2 Yes
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC427D
2
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN) • CFast 2 GB 1
Without operating system
• Celeron U827E (1C/1T, 1.4 GHz, 1
1.5 MB cache); 2 x Gigabit Ether- • CFast 4 GB 2
net (IE/PN); PROFIBUS DP12 (only optionally with operating
system if no internal mass storage)
• Celeron U827E (1C/1T, 1.4 GHz, 2
1.5 MB cache); 2 x Gigabit Ether- • CFast 8 GB 3
net (IE/PN); CAN interface (only optionally with operating
system if no internal mass storage)
• Core i3-3217UE (2C/4T, 1.6 GHz, 3
3 MB cache); 2 x Gigabit Ethernet • CFast 16 GB 4
(IE/PN) (only optionally with operating
system if no internal mass storage)
• Core i3-3217UE (2C/4T, 1.6 GHz, 4
3 MB cache); 2 x Gigabit Ethernet Internal mass storage:
(IE/PN); PROFIBUS DP12 • Without internal mass storage A
• Core i3-3217UE 5 • CFast 2 GB, without software B
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN); • CFast 4 GB, without software C
1 x PROFINET (IRT, 3 ports) • CFast 8 GB, without software D
• Core i7-3517UE 6 • CFast 16 GB, without software E
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 2 x Gigabit Ethernet • SSD 50 GB High Endurance (SLC) G
(IE/PN) (optional ECC only here) • SSD 80 GB Standard H
• Core i7-3517UE (2C/4T, 1.7 (2.8) 7 • HDD 250 GB K
GHz, 3 MB cache); 2 x Gigabit
Ethernet (IE/PN); PROFIBUS DP12 • SSD 160 GB Standard P
• Core i7-3517UE (2C/4T, 8 SIMATIC software preinstalled
1.7 (2.8) GHz, 3 MB cache); (bundles, only with Windows
1 x Gigabit Ethernet (IE/PN); Embedded Standard 7):
1 x PROFINET (IRT, 3 ports)
• Without SIMATIC software A
Mounting accessories: • WinAC RTX 2010 3) B
• without mounting accessories A • WinCC RT Advanced, 128 PT C
• DIN rail mounting B • WinCC RT Advanced, 512 PT D
• Wall mounting D • WinCC RT Advanced, 2 048 PT E
• Portrait mounting E • WinCC RT Advanced, 4 096 PT F
Work memory/NVRAM/ECC: • WinCC RT Advanced 128 PT, J
• 1 GB A WinAC RTX 2010 3)
• 2 GB B • WinCC RT Advanced 512 PT, K
WinAC RTX 2010 3)
• 4 GB C
• WinCC RT Advanced 2 048 PT, L
• 8 GB D WinAC RTX 2010 3)
• 4 GB with ECC (only with Core i7, G • WinCC RT Advanced 4 096 PT, M
2 x Gigabit Ethernet (IE/PN))
WinAC RTX 2010 3)
• 8 GB with ECC (only with Core i7, H
2 x Gigabit Ethernet (IE/PN)) • WinAC RTX F 2010 3) N
• 1 GB and NVRAM J • WinCC RT Advanced 128 PT, P
WinAC RTX F 2010 3)
• 2 GB and NVRAM K
• WinCC RT Advanced 512 PT, Q
• 4 GB and NVRAM L WinAC RTX F 2010 3)
• 8 GB and NVRAM M • WinCC RT Advanced 2 048 PT, R
• 4 GB with ECC and NVRAM (only N WinAC RTX F 2010 3)
with Core i7, 2 x Gigabit Ethernet
• WinCC RT Advanced 4 096 PT, S
(IE/PN))
WinAC RTX F 2010 3)
• 8 GB with ECC and NVRAM (only P
with Core i7, 2 x Gigabit Ethernet • WinCC RT Professional Client/ Y
(IE/PN)) single-user station 128 PT
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC627D
Rugged design for direct installation in the machine
■ Overview • Maximum processor performance up to ambient temperature
of 55 °C
• High shock/vibration resistance in all possible mounting
positions
• High EMC for safe operation
• SATA Solid-State Drive (SSD) with 240 GB for high reliability
2
and speed
• Strain relief for all cables/connectors
High system availability, fast startup,
maintenance and servicing
• High degree of data security thanks to mirror disk system
(RAID1, optional) or Solid State Drive (SSD, optional)
• ECC memory (optional, for 1-bit error correction)
• 2 MB battery-buffered SRAM, 128 KB of which can be used as
memory for retentive WinAC RTX data
• Active Management Technology (Intel AMT) for Xeon versions
(remote access to the device, also in shut-down state)
IPC627D with DVD drive • CMOS buffer battery accessible from outside, replaceable
during operation. Status can be scanned by software.
SIMATIC IPC627D (Box PC):
The high-end IPC – with maximum performance, • 4 LEDs – 1 x power and 3 x applications (WinAC)
functional scope and expansion capability • Operating system preinstalled, ready to run, and already
activated (eliminates need for usual product activation via the
It offers: Internet or by telephone)
• Maximum performance in the smallest space • Following system failure, fast restoration of hard disk contents
• Intel Xeon technology to as-delivered status using supplied recovery and restore CD
• Worldwide service and support
■ Benefits Cost reductions through high investment security
Maximum system performance for complex measuring, • Platform with long-term stability and embedded Intel
control and visualization tasks components
• Intel processors: Xeon, Core i3 or Celeron; • Availability of 3 to 6 years, then guaranteed availability of
in each case with 4 or 2 cores, with turbo-boost technology spare parts for further 5 years
and AMT (Xeon) and hyper-threading (Xeon, i3)
• Part of the scalable Box PC range with identical performance
• Intel DH82C226 PCH Platform Controller Hub (PCH) features and footprint
• DDR3 1600 memory technology up to 16 GB RAM • System-tested with SIMATIC components
• Intel HD 4600 (Xeon, i3) graphics for high graphics • Certification for worldwide marketing (e.g.: cULus)
performance
• Installation compatible for all device generations, software
• PCI Express x16 slot for x16 graphics card support compatible with predecessor model
• SATA hard disks with up to 500 GB capacity and NCQ
technology (Native Command Queuing) for larger data
volumes
Highly compact design for space-saving and
flexible installation
• Compact housing design (volume 6 liters)
• Flexible installation in many different positions with mounting
brackets or portrait installation kits
• Free expansion slots: 2 x PCI or 2 x PCIe or
1 x PCIe and 1 x PCI
• 3 X PROFINET interfaces onboard (optional, IRT-capable,
3-port, switching-enabled, CP 1616-compatible)
• 1 x PROFIBUS interface onboard (optional,
CP 5622-compatible)
• 2 x LAN 10/100/1000 Mbit/s connections (Gigabit Ethernet
with teaming capability), PROFINET RT-compatible
• 4 x USB 3.0 (SuperSpeed)
• DisplayPort and DVI-I interface (for VGA or DVI-D monitors)
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC627D
■ Technical specifications
SIMATIC IPC627D SIMATIC IPC627D
General features Monitoring functions
Processor • Intel Xeon Processor E3-1268L v3 Temperature and Watchdog Onboard
2 (4C, 2.3 (3.3) GHz, HT, 8 MB cache,
HT, VT-d, AMT) Status LEDs 4 LEDs
• Intel Core i3-4330TE Ambient conditions
(2C, 2.4 GHz, 4 MB cache, HT, VT-x)
• Intel Celeron G1820TE Degree of protection IP20 according to EN 60529
(2C, 2.2 GHz, 2 MB cache) (front/rear)
Main memory 2 GB; DDR3 1600, DIMM; Vibration load during operation 2) • 10 ... 58 Hz: 0.75 mm,
expandable up to 16 GB 58 ... 500 Hz: 9.8 m/s2 (approx. 1 g)
(2 memory receptacles); • with DVD operation:
ECC memory 8/16 GB optional 10 ... 58 Hz: 0.018 mm,
58 ... 500 Hz: 2.5 m/s2
Free slots for expansions • 1 x PCI (185 mm) and (approx. 0.25 g)
1 x PCI (185 mm) or
• 1 x PCI (185 mm) and Shock load during operation 3) • Tested according to
1 x PCIe x16 (185 mm) DIN IEC 68-2-29: 50 m/s2 (5 g),
• 2 x PCI-Express • with DVD operation:
(x16/x4, 185/185 mm) 50 ms2, 11 ms (5 g)
Operating system Relative humidity during operation 5 % to 80 % at 25°C
(no condensation);
Operating system • Without
• Windows 7 Ultimate Multi-Language Relative humidity during transport / 5% to 95% at 25 °C
– 32-bit or 64-bit variant, SP1 storage (no condensation)
Supply voltage 100 V /230 V / 240 V AC (widerange) Electromagnetic compatibility
50/60 Hz; optional 24 V DC (EMC)
Drives Emitted interference EN 61000-6-3,
EN 61000-3-2 Class D,
Optical drives SATA DVD±RW/DL Drive, optional EN 61000-3-3; FCC Class A
(Depth increases from 80 mm
to 100 mm) Immunity to interference
• to conducted interference ± 2 kV (IEC 61000-4-4, burst),
SATA hard disks None;
on the supply cables
250 GB, 500 GB, RAID1 (2 x 250 GB) ± 1 kV (IEC 61000-4-5, surge symm.),
±2 kV (IEC 61000-4-5, surge asymm.)
Solid state drive 240 GB SATA 2.5"
• on signal cables ± 1 kV
Approvals cULus508, cULus1950, (IEC 61000-4-4, burst, length < 3 m),
FCC Class A ± 2 kV
Ports (IEC 61000-4-4, burst, length > 3 m),
± 2 kV
DisplayPort 1 x DisplayPort (IEC 61000-4-5, surge,
length > 30 m)
DVI-I 1 x (analog OR digital)
• to discharge of static electricity ± 6 kV contact discharge
VGA Via adapter cable, DVI-I to VGA
(IEC 61000-4-2),
adapter (available as accessory)
± 8 kV air discharge
Dual Monitor Via DisplayPort and DVI-I (IEC 61000-4-2)
Parallel interface PC slot cover • to high-frequency radiation 10 V/m 80% AM, 80-1000 MHz and
(available as accessory) 1.4 - 2 GHz (IEC 61000-4-3);
1 V/m 80% AM, 2.0-2.7 GHz
Serial interface 1 x COM1
(IEC 61000-4-3),
PROFIBUS/MPI 12 Mbit/s 10 V, 10 kHz to 80 MHz
(isolated, CP 5622-compatible, (IEC 61000-4-6)
optional)
• to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
PROFINET 3 x RJ45
(CP 1616-compatible, optional) 1) • Ambient temperature during 5 to 45 °C
operation (maximum configuration);
USB 4 x USB 3.0, SuperSpeed; 5 to 50 °C
2 x USB 2.0 (optional) (up to 20 W load on PCI bus),
5 to 55 °C
Ethernet 2 x Gigabit Ethernet (up to 10 W load on PCI bus)
(IE, PN, RJ45, teaming-capable)
Dimensions
Device dimensions 312 x 301 (incl. mounting rail) x 105
(W x H x D) in mm without DVD drive:
312 x 301 (incl. mounting rail) x 80
Weight approx. 7 kg
2) No vibration permitted when burning DVDs;
1)
Note:
3) No shock permitted when burning DVDs
The PROFINET and PROFIBUS options are supplied with 2 MB battery-
backed SRAM
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC627D
2
2 x Gigabit Ethernet (IE/PN) RJ45; MUI (Eng, Ger, Fr, It, Sp);
4 x USB V3.0; 1x serial (COM1);
RAID controller onboard; • Windows 7 Ultimate, 64-bit SP1, B
watchdog, temp./fan monitoring; MUI (Eng, Ger, Fr, It, Sp);
• Without X
Processor:
• Core i3-4330TE (2C/4T, 2.4 GHz, expansions (SW)
D
4 MB cache, VT-x); • SIMATIC IPC DiagMonitor V4.x A
• Core i3-4330TE (2C/4T, 2.4 GHz, E enclosed;
4 MB cache, VT-x); • SIMATIC IPC Image & Partition B
PROFIBUS/MPI Creator V3.x enclosed;
(CP 5622-compatible);
2 MB battery-backed SRAM; • SIMATIC IPC DiagMonitor V4.x, C
Image & Partition Creator V3.x
• Core i3-4330TE (2C/4T, 2.4 GHz, F enclosed;
4 MB cache, VT-x);
PROFINET (IRT, 3 ports, • Without X
CP 1616-compatible); • TPM module Y
2 MB battery-backed SRAM; (not for China and Russia);
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) G
GHz, 8 MB cache, VT-d, AMT); Country-specific version/
power supply
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) H
GHz, 8 MB cache, VT-d, AMT); • 110/230 V AC industrial 0
PROFIBUS/MPI power supply with NAMUR;
(CP 5622-compatible); European power cable;
2 MB battery-backed SRAM; • 110/230 V AC industrial power 1
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) J supply with NAMUR;
GHz, 8 MB cache, VT-d, AMT); UK power cable;
PROFINET (IRT, 3 ports, • 110/230 V AC industrial power 2
CP 1616-compatible); supply with NAMUR;
2 MB battery-backed SRAM; power cable for Switzerland;
Drives • 110/230 V AC industrial power 3
supply NAMUR; US power cable;
• 250 GB HDD SATA; A
• 110/230 V AC industrial power 4
• 250 GB HDD SATA; DVD+/-RW; B supply NAMUR;
• 500 GB HDD SATA; D power cable for Italy;
• 500 GB HDD SATA; DVD+/-RW; E • 110/230 V AC industrial power 5
supply with NAMUR;
• RAID1 2 x 250 GB SATA (2.5"); G power cable for China
• RAID1 2 x 250 GB SATA (2.5"); H • 24 V DC industrial power supply; 6
DVD+/-RW; 1) For an up-to-date overview, see the SIMATIC PC online configurator at:
• Solid-state drive 240 GB; M www.siemens.com/ipc-configurator
• Solid-state drive 240 GB; 250 GB N
HDD SATA (2.5"); Accessories
• Solid-state drive 240 GB; 250 GB P Memory expansion
HDD SATA (2.5"); DVD+/-RW; • 2 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ50-0MA0
Memory configuration • 4 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ60-0MA0
• 8 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ70-0MA0
• 2 GB DDR3 1600 DIMM; 1
• 8 GB DDR3 1600 SDRAM, DIMM, 6ES7648-2AJ70-1MA0
• 4 GB DDR3 1600 DIMM; 2 ECC
• 8 GB DDR3 1600 DIMM; 3 Assembly kit for portrait mounting
• 16 GB DDR3 1600 DIMM; 4 • Upward or downward interface 6ES7648-1AA10-1YA0
• 8 GB DDR3 1600 DIMM; ECC; 5 outlet
• Interface outlet to the front 6ES7648-1AA10-1YB0
• 16 GB DDR3 1600 DIMM; ECC; 6
SIMATIC PC graphics 6ES7648-3AB00-0XA0
Expansion 1 (HW) adapter cable
• 2 x PCI; 0 DVI-I acc. to VGA, 250 mm long
• 1 x PCIe (x16); 1 x PCI; 1 SIMATIC PC power cable
• 1 x PCIe (x16); 1 x PCIe (x4); 2 for Box PC and Panel PC,
230 V AC, angled, 3 m
Expansion 2 (HW) • for Germany, France, Spain, 6ES7900-1AA00-0XA0
• Without expansions (HW); 0 the Netherlands, Belgium,
Sweden, Austria, Finland
• 2 x USB in addition 1 • for United Kingdom 6ES7900-1BA00-0XA0
(1 slot occupied); • For Switzerland 6ES7900-1CA00-0XA0
• COM2; LPT (1 slot occupied); 2 • For the USA 6ES7900-1DA00-0XA0
• 2 x USB in addition; COM2; LPT 3 • For Italy 6ES7900-1EA00-0XA0
(2 slots occupied); • For China 6ES7900-1FA00-0XA0
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC827D
Rugged design for direct installation in the machine
■ Overview • Maximum processor performance up to an ambient temper-
ature of 55 °C
• High shock/vibration resistance in all possible mounting
positions
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC827D
■ Technical specifications
SIMATIC IPC827D SIMATIC IPC827D
General features Ambient conditions
Processor • Intel Xeon Processor E3-1268L v3 Degree of protection IP20 according to EN 60529
(4C, 2.3 (3.3) GHz, HT, 8 MB cache,
HT, VT-d, AMT)
Vibration load in operation 2)
(front/rear)
• 10 ... 58 Hz: 0.75 mm,
2
• Intel Core i3-4330TE (2C, 2.4 GHz,
4 MB cache, HT, VT-x) 58 ... 500 Hz: 9.8 m/s2 (approx. 1 g)
• Intel Celeron G1820TE • with DVD operation:
(2C, 2.2 GHz, 2 MB cache) 10 ... 58 Hz: 0.018 mm,
58 ... 500 Hz: 2.5 m/s2
Main memory 2 GB; DDR3 1600, DIMM; (approx. 0.25 g)
expandable up to 16 GB
(2 memory receptacles); Shock load during operation 3) • Tested according to
ECC memory 8/16 GB optional DIN IEC 68-2-29: 50 m/s2 (5 g),
• with DVD operation: 50 ms2,
Free slots for expansions 2 x PCI (240 mm) 11 ms (5 g)
1 x PCI (185 mm) Relative humidity during operation 5 % to 80 % at 25°C
2 x PCI-Express (no condensation);
(x16/x4, 185/185 mm) Relative humidity during 5% to 95% at 25°C
Operating system transport / storage (no condensation)
Operating system • Without Electromagnetic compatibility
• Windows 7 Ultimate Multi-Language (EMC)
– 32-bit or 64-bit variant, SP1 Emitted interference EN 61000-6-3,
Supply voltage 100 V /230 V / 240 V AC (widerange) EN 61000-3-2 Class D,
50/60 Hz; EN 61000-3-3;
optional 24 V DC FCC Class A
Drives Immunity to interference
• to conducted interference on the ± 2 kV
Optical drives DVD±RW/DL SATA, optional (depth supply cables (IEC 61000-4-4, burst),
increases from 155 mm to 179 mm)
± 1 kV
SATA hard disks None; 250 GB, 500 GB, RAID1 (IEC 61000-4-5, surge symm.),
(2 x 250 GB) ±2 kV
(IEC 61000-4-5, surge asymm.)
Solid state drive 240 GB SATA 2.5"
• on signal cables ± 1 kV
Approvals cULus508, cULus1950, (IEC 61000-4-4, burst, length < 3 m),
FCC Class A ± 2 kV
Ports (IEC 61000-4-4, burst, length > 3 m),
± 2 kV
DisplayPort 1 x DisplayPort (IEC 61000-4-5, surge, length > 30 m)
DVI-I 1 x (analog OR digital) • to discharge of static electricity ± 6 kV contact discharge
(IEC 61000-4-2),
VGA Via adapter cable, DVI-I to VGA ± 8 kV air discharge
adapter (available as accessory) (IEC 61000-4-2)
Dual Monitor Via DisplayPort and DVI-I • to high-frequency radiation 10 V/m 80% AM, 80-1000 MHz and
1.4 - 2 GHz (IEC 61000-4-3);
Parallel interface PC slot cover 1 V/m 80% AM, 2.0-2.7 GHz
(available as accessory) (IEC 61000-4-3),
Serial interface 1 x COM1 10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)
PROFIBUS/MPI 12 Mbit/s • to magnetic fields 100 A/m,
(isolated, CP 5622-compatible, 50/60 Hz (IEC 61000-4-8)
optional)
• Ambient temperature during opera- 5 to 45 °C
PROFINET 3 x RJ45 tion maximum configuration);
(CP 1616-compatible, optional) 1) 5 to 50 °C
(up to 20 W load on PCI bus),
USB 4 x USB 3.0, SuperSpeed; 5 to 55 °C
2 x USB 2.0 (optional) (up to 10 W load on PCI bus)
Ethernet 2 x Gigabit Ethernet Dimensions
(IE, PN, RJ45, teaming-capable)
Device dimensions (W x H x D) in mm 312 x 301 (incl. mounting rail) x 179
Monitoring functions without DVD drive: 312 x 301
Temperature and Watchdog Onboard (incl. mounting rail) x 155
Status LEDs 4 LEDs Weight approx. 8 kg
1)
Note: The PROFINET and PROFIBUS options are supplied with 2 MB
battery-backed SRAM
2)
No vibration permitted when burning DVDs;
3)
No shock permitted when burning DVDs
PROFINET/Industrial Ethernet
Industrial PC
Box PC
SIMATIC IPC827D
2
2 x Gigabit Ethernet (IE/PN) RJ45; MUI (Eng, Ger, Fr, It, Sp);
4 x USB V3.0;
1x serial (COM1); • Windows 7 Ultimate 64-bit SP1, B
RAID controller onboard; MUI (Eng, Ger, Fr, It, Sp);
watchdog, temp./fan monitoring; • Without X
Processor: expansions (SW)
• Celeron G1820TE A • SIMATIC IPC DiagMonitor V4.x A
(2C/2T, 2.2 GHz, 2 MB cache) enclosed;
• Celeron G1820TE B • SIMATIC IPC Image & Partition B
(2C/2T, 2.2 GHz, 2 MB cache); Creator V3.x enclosed;
PROFIBUS/MPI • SIMATIC IPC DiagMonitor V4.x, C
(CP 5622-compatible); Image & Partition Creator V3.x
2 MB battery-backed SRAM 2) enclosed;
• Celeron G1820TE C • Without X
(2C/2T, 2.2 GHz, 2 MB cache);
PROFINET (IRT, 3 ports, • TPM module Y
CP 1616-compatible); (not for China and Russia);
2 MB battery-backed SRAM Country-specific version/
• Core i3-4330TE (2C/4T, 2.4 GHz, D power supply
4 MB cache, VT-x)
• 110/230 V AC industrial power 0
• Core i3-4330TE (2C/4T, 2.4 GHz, E supply with NAMUR; European
4 MB cache, VT-x); power cable;
PROFIBUS/MPI
(CP 5622-compatible); • 110/230 V AC industrial power 1
2 MB battery-backed SRAM 2) supply with NAMUR; UK power
cable;
• Core i3-4330TE (2C/4T, 2.4 GHz, F
4 MB cache, VT-x); • 110/230 V AC industrial power 2
PROFINET (IRT, 3 ports, supply with NAMUR; power cable
CP 1616-compatible); for Switzerland;
2 MB battery-backed SRAM • 110/230 V AC industrial power 3
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) G supply NAMUR; US power cable;
GHz, 8 MB cache, VT-d, AMT) • 110/230 V AC industrial power 4
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) H supply NAMUR; power cable for
GHz, 8 MB cache, VT-d, AMT); Italy;
PROFIBUS/MPI • 110/230 V AC industrial power 5
(CP 5622-compatible); supply with NAMUR; power cable
2 MB battery-backed SRAM 2) for China
• Xeon E3-1268Lv3 (4C/8T, 2.3 (3.3) J • 24 V DC industrial power supply; 6
GHz, 8 MB cache, VT-d, AMT);
PROFINET (IRT, 3 ports, 1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
CP 1616-compatible); www.siemens.com/ipc-configurator
2 MB battery-backed SRAM 2)
Expected start of delivery: 2nd quarter 2014
Drives
• 250 GB HDD SATA; A Accessories
• 250 GB HDD SATA; DVD+/-RW; B Memory expansion
• 500 GB HDD SATA; D • 2 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ50-0MA0
• 500 GB HDD SATA; DVD+/-RW; E • 4 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ60-0MA0
• RAID1 2 x 250 GB SATA (2.5"); G • 8 GB DDR3 1600 SDRAM, DIMM 6ES7648-2AJ70-0MA0
• RAID1 2 x 250 GB SATA (2.5"); H • 8 GB DDR3 1600 SDRAM, DIMM, 6ES7648-2AJ70-1MA0
DVD+/-RW ECC
• Solid-state drive 240 GB; M
Assembly kit for portrait mounting
• Solid-state drive 240 GB; 250 GB N
HDD SATA (2.5"); • Upward or downward interface 6ES7648-1AA30-1YA0
outlet
• Solid-state drive 240 GB; 250 GB P
HDD SATA (2.5"); DVD+/-RW; • Interface outlet to the front 6ES7648-1AA30-1YB0
Memory configuration SIMATIC PC graphics adapter cable 6ES7648-3AB00-0XA0
• 2 GB DDR3 1600 DIMM; 1 DVI-I acc. to VGA, 250 mm long
• 4 GB DDR3 1600 DIMM; 2 SIMATIC PC power cable
• 8 GB DDR3 1600 DIMM; 3 for Box PC and Panel PC, 230 V AC,
• 16 GB DDR3 1600 DIMM; 4 angled, 3 m
• 8 GB DDR3 1600 DIMM; ECC; 5 • for Germany, France, Spain, the 6ES7900-1AA00-0XA0
Netherlands, Belgium, Sweden,
• 16 GB DDR3 1600 DIMM; ECC; 6 Austria, Finland
Expansions (HW) • for the United Kingdom 6ES7900-1BA00-0XA0
• 1 x PCIe (x16); 1 x PCIe (x4); 0 • For Switzerland 6ES7900-1CA00-0XA0
3 x PCI • For the USA 6ES7900-1DA00-0XA0
Expansion 2 (HW) • For Italy 6ES7900-1EA00-0XA0
• Without expansions (HW); 0 • For China 6ES7900-1FA00-0XA0
• 2 x USB in addition 1
(1 slot occupied);
• COM2; LPT (1 slot occupied); 2 ■ More information
• 2 x USB in addition; COM2; LPT 3 Additional information is available on the Internet at:
(2 slots occupied);
http://www.siemens.com/simatic-pc
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
General data
■ Overview
SIMATIC IPC477D:
The powerful embedded Panel PC – maintenance-free
with versatile configuration
2
• Compact design
• High performance with highly compact design and
ruggedness
• Flexible expansion using a PCIe I/O card (optional)
• No rotating parts (without fan and hard disk)
• High security due to use of the operating system
• Windows Embedded Standard 7
• Ready-to-use devices with optionally preinstalled software
• HMI: Innovative HMI software WinCC RT Advanced
• (including logging and recipes)
• RTX: with real-time capable software PLC WinAC RTX
• Retentive memory on-board
• (NV-RAM, usable with WinAC RTX)
SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control SIMATIC HMI IPC477C: The powerful embedded Panel PC –
panels, as well as directly on the machine. Typical areas of appli- maintenance-free with versatile configuration
cation can be found in both factory and process automation. • Compact design
There is a broad range of robust, high-performance • High performance with highly compact design and
SIMATIC Panel PCs available for different requirements. ruggedness
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
General data
■ Benefits
High degree of industrial capability Expandability
The entire construction is designed for purely industrial use. Depending on the model, ISA, PCI, PCI Express, PC/104 Plus
Thus, for example, a special vibration-absorbing suspension and PC/104 slots are available for individual expandability.
2 of the hard disk ensures operational reliability, even at high
mechanical loads. This makes that the SIMATIC Panel PCs are
This enables the further use of existing and new expansion
cards.
designed for a vibration load of 1 g and a shock load of 5 g.
Compact dimensions
Performance
Considering the desired expandability, SIMATIC Panel PCs have
Thanks to the use of the latest Intel processors from ULV an extremely low mounting depth and can thus be used in very
(Ultra Low Voltage) to Intel Core technology, SIMATIC Panel PCs narrow installation locations.
are flexibly scalable for your application.
Options
• Scalable computing power
• Highest computing power Various options enable an individual solution for your industrial
• Latest Intel processor technology application. Thus, the operator control unit can be operated
separately from the computer unit by up to 30 m. The direct con-
• Core i, Dual Core, ULV, Atom trol key module increases the operating safety in that it can be
Investment security used to run the process independently of the operating system
and without delay directly on PROFIBUS DP/MPI.
High component continuity and guaranteed availability of spare
parts for up to 5 years after product phase-out are ensured Individually expandable system availability
e.g. through the development and production of our own • RAID1 configuration - high system stability through redundant
motherboards. This enables long-lasting machine concepts data management
without renewed engineering effort. • SIMATIC IPC DiagMonitor – Monitoring of the operating states
Service-friendly device design and early detection of problems locally and in the network
Upgrades and exchange of components are easy thanks to the • SIMATIC IPC Image & Partition Creator – downtime minimi-
device design. zation through preventive data backup
• SITOP and Masterguard power supply (UPS) – Bridging of
Integrated interfaces voltage dips
The different already-integrated interfaces allow for various
communication and expansion options. Many models are
already equipped with Gigabit Ethernet and PROFIBUS DP/MPI
interface.
■ Technical specifications
SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI SIMATIC HMI SIMATIC HMI
IPC477C IPC577C IPC677D 7)
Design
Centralized configuration • • • • •
Display
Size 7"/9"/12"/15"/19“ 12"/15"/19"/22" 12"/15"/19" TFT 12"/15"/19" TFT 22" Widescreen TFT
Widescreen TFT Widescreen TFT
Resolution 800 x 480 / 1280 x 800 / 800 x 600 / 800 x 600 / 1 920 x 1 080
800 x 480 / 1280 x 800 / 1024 x 768 / 1 024 x 768 /
1280 x 800 / 1366 x 768/ 1280 x 1024 1 280 x 1 024
1280 x 800 / 1920 x 1080
1366 x 768
Operator controls
Membrane keyboard - • 8) • 1) • 1) -
Touch screen • • • • •
General features
Power supply •/- •/- •/- •/• •/•
24 V DC / 110/240 V AC
Processor • Intel Atom E640, • Intel Core i7-3517UE, • Intel Celeron M • Intel Celeron M • Intel Xeon E3-1268L
1.0 GHz; 1.7 GHz, 1.2 GHz 1.2 GHz v3 (4C, 2.3 (3.3) GHz,
• Intel Atom E660, 4 MB SLC • Intel Core2 Solo • Intel Core2 Solo HT, 8 MB cache,
1.3 GHz • Intel Core i3-3217UE, 1.2 GHz 1.2 GHz VT-d, AMT)
1.6 GHz, • Intel Core2 Duo • Intel Core2 Duo • Intel Core i3-4330TE,
3 MB SLC 1.2 GHz 1.86 GHz (2C, 2.4 GHz,
• Intel Celeron 827E 4 MB cache,
1.4 GHz, HT, VT-x)
1.5 MB SLC • Intel Celeron
G1820TE
(2C, 2.2 GHz,
2 MB cache)
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
General data
• Available
- Not available
1) 6)
12"/15" displays +0 °C to +50 °C; max. +50 °C in installation space;
2)
All slots with card retainer max. 40 °C if at the front
7)
3)
Valid with CF or SSD; with HDD: 5 g / 0.5 g; +0 °C to +45 °C for 19"
8)
4)
3 W taken into account for each PCI/PCIe slot 15" display optionally as Touch/Key version
9)
5)
15 W taken into account for each PCI/PCIe slot With 12" and 15", vertical installation and use of CFast or SSD
■ More information
Additional information is available on the Internet at: Examples are:
http://www.siemens.com/simatic-panel-pc • Specific front panels for SIMATIC Panel PC, e.g. honing oil-
resistant or with lateral function/movement keys
Note:
• SIMATIC HMI Net Panel with 46" large-scale display
Do you need a specific modification or extension to the products
described here? Then refer to "Customized Automation".
There you will find information about additional and generally
available sector-specific products as well as options for
customer-specific modification and adaptation.
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
SIMATIC IPC277D
■ Overview ■ Benefits
SIMATIC IPC277D Nanopanel PC
• Rugged, industry-standard widescreen displays (Touch)
with 7" / 9" / 12" / 15"/ 19"
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
SIMATIC IPC277D
■ Technical specifications
SIMATIC IPC277D SIMATIC IPC277D
General features Monitoring functions
Processors • Intel Atom E660 1.3 GHz, 2 GB RAM Temperature • Processor temperature
Chipset
• Intel Atom E640 1.0 GHz, 1 GB RAM
Intel Controller Hub EG20T
• Motherboard
Messages can be evaluated by the
2
application program
NVRAM optional 512 KB, of which 128 KB
can be written within the buffer time Watchdog • Monitoring of program execution
• Monitoring time can be
Operating system • Windows Embedded Standard parameterized in software
2009 preinstalled, • Can be parameterized for a fault
in combination with CF card of 2 GB or restart
or more,
or solid-state drive, or hard drive Messages can be evaluated
(optional) by the application program
• Windows XP Professional MUI Monitoring functions via the network • DiagBase
(in connection with solid-state drive • SIMATIC IPC DiagMonitor
or hard drive;
MUI: Multi Language User Interface Remote monitoring capability for:
(optional) • Watchdog
• Windows Embedded Standard 7 • Temperature
32-bit, preinstalled, • Mass memory monitoring (SMART)
in combination with CF card or • System/Ethernet monitoring
solid-state drive (optional) (Heart Beat)
• Windows 7 Ultimate MUI 32-bit • Runtime meter
(in combination with Communication:
solid-state drive; • Ethernet interface (SNMP protocol)
MUI: Multi Language User Interface • OPC for integration in SIMATIC
(optional) software
• Linux 1) • Configuration of client/server
(project-specific, on request) architectures
Others on request project-specifically • Structure of log files
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
SIMATIC IPC277D
2 Display
Resolution (W x H in pixels) 800 x 480 800 x 480 1 280 x 800 1 280 x 800 1 366 x 768
General features
Accessories Touch pen, Touch pen, Touch pen, Touch pen, Touch pen,
touch protective films touch protective films touch protective films touch protective films touch protective films
Type of operation
Function keys No No No No No
Alphanumeric keyboard No No No No No
Touch screen (analog/resistive) Yes Yes Yes Yes Yes
USB port on the front No No No Yes Yes
Design
Centralized configuration Yes Yes Yes Yes Yes
Distributed configuration No No No No No
Dimensions
Mounting dimensions 197 x 141 x 71 251 x 166 x 71 310 x 221 x 66 396 x 291 x 73 465 x 319 x 73
in centralized configuration
(W x H x D) in mm
Operator control unit (W x H) in mm 214 x 158 274 x 190 330 x 241 415 x 310 483 x 337
Weight 1500 g 1950 g 2750 g 4000 g 5700 g
Max. power loss 27 W 29 W 37 W 42 W 45 W
in maximum configuration
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
SIMATIC IPC277D
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-panel-pc
PROFINET/Industrial Ethernet
Industrial PC
SIMATIC Panel PC
SIMATIC IPC477D
■ Overview ■ Benefits
• Excellent industrial compatibility due to rugged construction,
even when subjected to extreme vibration and shock
• High degree of investment protection thanks to assured
availability of spare parts for a period of 5 years following the
2 end of active marketing
• Excellent continuity of components for machine concepts with
a long service life without any new engineering costs
• Cost and time savings due to service-friendly device design:
- Front and rear USB 2.0 ports for quick and easy connection
of additional hardware components
• High degree of industrial functionality thanks to integral
PROFIBUS DP/MPI and PROFINET interfaces
• Maintenance-free due to lack of rotating components
(fan and hard disk)
• High flexibility thanks to expansions (optional) such as PCIe,
second RS 232, DVD (not with 12" TFT Touch)
• Minimization of downtimes thanks to high system availability
- Efficient self-diagnostics (DiagBase and SIMATIC IPC
SIMATIC IPC477D: DiagMonitor)
The powerful embedded Panel PC – maintenance-free - High reliability and security of an embedded platform
with versatile configuration • An integral component of Totally Integrated Automation (TIA):
• Embedded PC platform with extremely high industrial compat- - Enhanced productivity, minimization of