Specification EML500
GS 80B80M01E 7th Electromagnetic Log
General
The EML500 series electromagnetic log confirms to the
technical requirements for the performance standard
determined by IMO Resolution A824(19) and MSC.96(72) also
meet type approval issued by the Transport Ministry of JG
Performance specification
- Measurement range
Speed : -4kt to +20kt (Note 1
-5kt to +25kt (Note 1
-7kt to +35kt
-8kt to +40kt
-10kt to +50kt (Note 2
-13kt to +65kt (Note 2
(Note 1 MED is attended in case of Single-axis system (range
of “-4kn to 20kn” or “-5kn to 25kn”).
(Note 2 Additional engineering is required concerning the
installation of the sensor.
Trance verse speed : 0kt to ±6.5kt (for Dual-axis)
Distance : 0nm to 9999.99nm
GS 80B80M01E
1998.03 6th (YDK)
2002.12 7th (YDK)
2
Environmental conditions
- Ambient temperature : operating -15℃ to +55℃ - Noise of power source line :
not operating -20℃ to +60℃ Not failure in the state put on the pulse 100/400nsec, 1500V
- Humidity : 95% RH (no dew condensation around) during three minutes.
- Vibration : 5 to 12.5Hz ±1.6mm - Insulation resistance :
12.5 to 25Hz ±0.38mm At last 10Ω using a 500V megger (Excluding electronic circuit)
25 to 50Hz ±0.1mm - Withstanding voltage
1500V AC for 1min. (Excluding electronic circuit)
or
Dimmer box
(LD001A)
Ship’s power supply
100V to 230V AC
Case of Outside dimmer Dimmer box
(MKD002)
Master unit
(LT501)
Serial signal (YDK format)
Ship’s Speed
(NMEA0183) Serial signal (NMEA0183 format)
GPS VDR
Speed indicator
Analog signal (Voltage signal) : 4 circuit (LR523)
(0V to 5V DC or 1V to 5V DC)
ECDIS
(Option)
Ship’s power supply
100V to 115V AC Analog signal (Current signal) : 2 circuit
or (0A to 20mA or 4 to 20mA)
200V to 230V AC
GYRO COMPASS
AUTO PILOT
INS
RADAR
Sea water valve Sea water valve Sea water valve Sea water valve
(LV033) (LV033) (LV071A) (LV052)
Φ35 sensor Φ35 sensor Φ70 sensor Φ48 sensor
(LS501) (LS531) (LS571 : Single axis) (LS541 : Single sxis)
Protective pipe Rodmeter (LS572 : Dual axis) (LS542 : Dual axis)
(LV905) (LS591)
Lower flange
(LV904)
(Note 1) In case of dual-axis, transverse speed may not be able to the mounting −N Illumination not use
position of sensor. X4 −R EL board Orange color
(Note 2) About 50/60kt correspondence, additional engineering is required concerning Dimmer / Power supply 1 External/100V to 115V AC 50/60Hz 1Φ
the installation of the sensor.
(Note 3) MED is attended in case of System X2 = 1 (Single-axis) and X4 = 1 2 (Note 2) Built-in /100V to 115V AC 50/60Hz 1Φ
(-4kn to 20kn) or X4 = 2 (-5kn to 25kn) 3 External/200V to 230V AC 50/60Hz 1Φ
(Note 4) Please append external speed signal (NMEA0183) format with order sheet. 4 (Note 2) Built-in /200V to 230V AC 50/60Hz 1Φ
5 External/LED illumination
6 Built-in /LED illumination
X5 N Illumination not use
Wiring position 1 Cormingφ25
X6 2 Grand (Note 3)
Rule / Name plate 1 None / Japanese & English
2 JG / Japanese & English
3 JG / Japanese
X7 4 None / English
Color 1 YDK Standard (CC24 brown)
2 Munsell 2.5G7/2
X8 3 Munsell 7.5BG7/2
Name plate −1 HV2
X9 −2 FA2
Option /CHS Name plate in Chinese
(Note 1) Case of Resultant speed /Direction are not indicate (-) data. Indicate
0 to XX kt.
(Note 2) X5 = 2 and X5 = 4 are use for LR525 built-in dimmer unit only.
(Note 3) X6 = 2 Grand is use for Wall mount only. (15b, 20c each 1 use)
Outline
LN052 Junction box
24V 1
GND 2
FG 3
RDA 4
RDB 5
SDA 6
SDB 7
N.C 8
LR524-F Analog indicator (Flash mount) LR525-F Analog indicator (Flash mount)
(Power supply 100V to 115VAC) (Power supply 200V to 230VAC)
Single-axis Dual-axis
- Dual : - Dual :
resultant speed /direction longitudinal / transverse speed