General EML500 series

Specification EML500
GS 80B80M01E 7th Electromagnetic Log

General
The EML500 series electromagnetic log confirms to the
technical requirements for the performance standard
determined by IMO Resolution A824(19) and MSC.96(72) also
meet type approval issued by the Transport Ministry of JG

Certificate number of type approval


- JG : No. 3795
- MED

Features Notified Body No.:


1) Small size and light weight compared ordinary models. 0434
2) The length of cable between the sensor and the master unit
can be extended maximum 300m by adoption of the - Single-axis sensor (right)
preamplifier built . - Dual-axis sensor (right)
3) Full provision of various external interfaces - LR524 Speed indicator : single axis (middle)
- Pulse output (Photo coupler / contact) - LR523 Master indicator (left)
- Digital signal (NMEA0183) - LT501 Master unit (left)
- Analog signal (0V to 5V DC / 0A to 20mA) Dictation of ship movement : 0 to 359 deg., clockwise from the
- Alarm contact output and Digital I/F form GPS bow-to-stern line (fixed to 0 deg. if the resultant
4) Reduction in the number of parts by employment of highly speed is 0.5kt or less)
integrated circuits including microprocessor, and has no - Measuring accuracy
moving parts, thereby achieving high reliability. Speed : - Measurement accuracy
5) Provision of small size and light weight master indicator for 1% of the speed of the ship, or 0.2 knots,
indication of speed and distance, and can be operated by the whichever is greater.
master indicator. Milepost calibration etc., thereby, - Indicate accuracy
installation place of master indicator is not limited. ±0.15kt with respect to standard signal input
6) Variety of sensors available to meet various instillation (±0.25kt or less if the measuring range is
requirements. A dual-axis sensor can measure not only the above 50kt)
longitudinal, speed but also the transverse speed. Distance : ±0.05nm/h or ±1.0% max., whichever is larger
7) Built-in self-diagnostic function. Direction of ship direction : ±2.5 deg. max.
8) All indicators can be driven by input signal (NMEA0183) from
- Response speed
GPS.
Variable up to 2min for a 0 to FS-step input (0% to 90%
General specification response)
- Measurement subject : Ship’s water speed and distance
- Measurement principle : Faraday’s law of - Restriction of the cables between each equipments
electromagnetic induction

Performance specification
- Measurement range
Speed : -4kt to +20kt (Note 1
-5kt to +25kt (Note 1
-7kt to +35kt
-8kt to +40kt
-10kt to +50kt (Note 2
-13kt to +65kt (Note 2
(Note 1 MED is attended in case of Single-axis system (range
of “-4kn to 20kn” or “-5kn to 25kn”).
(Note 2 Additional engineering is required concerning the
installation of the sensor.
Trance verse speed : 0kt to ±6.5kt (for Dual-axis)
Distance : 0nm to 9999.99nm

GS 80B80M01E
1998.03 6th (YDK)
2002.12 7th (YDK)
2
Environmental conditions
- Ambient temperature : operating -15℃ to +55℃ - Noise of power source line :
not operating -20℃ to +60℃ Not failure in the state put on the pulse 100/400nsec, 1500V
- Humidity : 95% RH (no dew condensation around) during three minutes.
- Vibration : 5 to 12.5Hz ±1.6mm - Insulation resistance :
12.5 to 25Hz ±0.38mm At last 10Ω using a 500V megger (Excluding electronic circuit)
25 to 50Hz ±0.1mm - Withstanding voltage
1500V AC for 1min. (Excluding electronic circuit)

System configuration diagram

Analog speed indicator Digital display Universal data display


(LR221) (MHR110)
Master indicator (LR524) Single-axis (LR525) Dual-axis (Option) (Option)
(LR523)

or

Dimmer box
(LD001A)
Ship’s power supply
100V to 230V AC
Case of Outside dimmer Dimmer box
(MKD002)
Master unit
(LT501)
Serial signal (YDK format)

Ship’s Speed
(NMEA0183) Serial signal (NMEA0183 format)
GPS VDR
Speed indicator
Analog signal (Voltage signal) : 4 circuit (LR523)
(0V to 5V DC or 1V to 5V DC)
ECDIS
(Option)
Ship’s power supply
100V to 115V AC Analog signal (Current signal) : 2 circuit
or (0A to 20mA or 4 to 20mA)
200V to 230V AC

Pulse signal (contact signal) (200p/nm)


Junction box
(LN052)
Pulse signal (Photo coupler ) (200p/nm)
ARPA

GYRO COMPASS

AUTO PILOT

INS

RADAR

EML500-HD1 (Single-axis) EML500-HS1 (Sigle-axis) EML500-HV1/HV2 EML500-FA1/FA2


Φ35F Double-bottom type Φ35F Single-bottom type (Single / Dual axis) (Single / dual axis)
Φ70F Single-bottom type Φ48F Single-bottom type

Sea water valve Sea water valve Sea water valve Sea water valve
(LV033) (LV033) (LV071A) (LV052)
Φ35 sensor Φ35 sensor Φ70 sensor Φ48 sensor
(LS501) (LS531) (LS571 : Single axis) (LS541 : Single sxis)
Protective pipe Rodmeter (LS572 : Dual axis) (LS542 : Dual axis)
(LV905) (LS591)
Lower flange
(LV904)

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


3
Component models of EML500
EML500 is composed of Master unit, Master indicator and Sea-bottom (with sensor).
And if it is necessary, combined with speed indicator and environ equipments.

Basic system models


According to type of Sensor unit, basic system model is set.

Component Models : EML500−☐☐☐

Sensor unit code

System Type EML500−☐☐☐


備 考
Product Name and Model HS1 HD1 HV1 RD1 FA1 HV2 FA2
Master unit LT501 ○ ○ ○ ○ ○ ○ ○
Master indicator LR523 ○ ○ ○ ○ ○ ○ ○
Speed indicator (Single-axis) LR524 ○ ○ ○ ○ ○
Speed indicator (Dual-axis) LR525 ○ ○
Dimmer box LD001A ○ ○ ○ ○ ○ ○ ○
Junction box LN052 ○ ○ ○ ○ ○ ○ ○
LS531 ○ Φ35sensor with cable
LS501 ○ ○ Only sensor element Φ35
LS571 ○ Φ70 sensor (Single-axis)
Sensor
LS541 ○ Φ48 sensor (Single-axis)
LS542 ○ Φ48 sensor (Dual-axis)
LS572 ○ Φ70 sensor (Dual-axis)
LS592 ○ Not including the sensor
Rodmeter
LS591 ○ Not including the sensor
Sensor cable LS503 ○ ○ ○ ○ ○ ○
LV033 ○ ○ For sensors Φ35
LV071A ○ ○ For sensors Φ70
Seawater valve
LV052 ○ ○ For sensors Φ48
LV031 ○ For sensors Φ35
Sensor unit

Seawater valve flange LV904 ○ ○


LV905 ○
Protection tube
LV903 ○
LV902 △
LV902A−1☐ △
Mounting
LV902A−2☐ △
plate for
LV902A−3☐ △
seawater
LV902A−4☐ △ △
valve
LV902A−5☐ △ △
LV910 △
LV901−1☐ △ △
LV901−2☐ △
Zinc plate Note: For Flash-mounted
△ △
LV901−3☐ unit (Unnecessary for a
(Note) (Note)
protruding unit)
Installation Single- Double- Single- Double- Single- Single- Single-
type bottom bottom bottom bottom bottom bottom bottom
Sensor
7mm 13mm 7mm 13mm
installation Standard length
50mm 50mm or 50mm or or or Length from bottom plate
of protrusion
57mm 73mm 57mm 73mm
Note : Items marked with a “ △ ” are ordered from the shipbuilder as standard.

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


4
Engineering specification
- Power - Analog speed signal : Current output (4 circuit)
100V to 115V AC or Output level : select able from 0mA to 20mA or 4mA to 20mA
200V to 230V AC ±10% 50/60Hz ±6%
(Selectable by the jumper setting in the power supply unit)
- Power consumption
80VA
- Input signal
- Input the detected voltage at sensor
0.242mA/knot (from sensor)
- Input from GPS (for back-up by GPS)
Data format of GPS input can be set by Master indicator.
Connection units : GPS, Other speed sensor
Transmission format: Asynchronous serial data signal
Transmission rate : 4800bps - Distance pulse output : Photo coupler type (8 circuit)
Data character : Start bit 1 bit Capacity : Voltage between terminals 24V max
Data bit 8 bit Shink current 5mA max.
Stop bit 1 bit Dark current 50µA max.
Parity None (at 24V between terminals)
Data format Pulse weight 200P/nm
Recommend format : based on IEC61162-1, VTG, - Distance pulse output : Relay contact type (2 circuit)
VBW, VHW and etc... Capacity : Rate loads 30V DC, 1A
Header character : 6 ASCII letter (resistance load) 30V AC, 0.5A
(Example : $GPVTG and etc...) Minimum appliciate load 10mV DC, 10µA
Chattering 1msec max.
Position of speed data:
Pulse weight 200P/nm
Set data based on the location of commas.
Check sum : Select Use or Unused
- Serial signal output
Input circuit : Photo coupler
Serial signal : based on NMEA0183 (Ver.2.0)
Transmission format : Asynchronous serial data signal
Transmission rate : 4800bps
Transmission period : 1sec
Transmission length : 1.2km
Data character : Start bit 1 bit
- Output signal Data bit 8 bit
- Analog speed signal : Voltage output (2 circuit) Stop bit 1 bit
Output level : Select able from 0V to 5V or 1V to 5V Parity None
Connected Device : RADAR, ECDIS and etc..
Output circuit : EIA RS-422-A

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


5
- Data format (based on NMEA0183 Ver.2.0) - Checksum
VBW sentence Checksum is the 8-bit exclusive-OR (no start or stop bits) of
all characters in the sentence, including “,” delimiters, but
not including the “$” and the “*” delimiters.
- Speed limit output (2 circuits)
Contact : At state of speed limit “Close” (standard)
At state of speed limit “Open”
(Selectable by Dip.SW 9-2(off: close, on: open))
Capacity : Rate loads 30V DC, 1A
Data block format (resistance load) 30V AC, 0.5A
1) for single-axis Minimum appliciate load 10mV DC, 10µA
Chattering 1msec max.
Setting : The higher or lower speed limit can be set by
Master indicator.
2) for dual-axis - Alarm contact output (2 circuits)
Contact : At abnormal “Close” (standard)
At abnormal “Open”
(Selectable by Dip.SW 9-3(off: close, on: open))
Capacity : Rate loads 30V DC, 1A
3) When the GPS speed is selected
(resistance load) 30V AC, 0.5A
Minimum appliciate load 10mV DC, 10µA
Chattering 1msec max.
Failure alarm - ROM/RAM error
4) When the system error is detected - Low battery (less than 2.1V)
- A/D converter error
- GPS input error
VHW sentence - Communication error between Master unit
and Master indicator.
Comportment equipment specification
- Master unit LT501
Receives and converters speed data signals from the
sensor. Then transmits the speed and distance to external
devices in various signal forms.
- Wiring position : Coaming of under or back
Data block format
- Installation : Wall or flush mounted type
1) at normal operation

- Master indicator LR523


Receives digital signals from the master unit, and displays
2) When the system error is detected the speed and distance. Both the display and operation
panel are on the front of the master indicator. Set data are
sent to the master unit in the form of digital signals, and
VLW sentence placed in the memory.
- Display function
The speed and distance are displayed with digital by LED
indicator.
1) Indicate of the Speed and Distance
Speed : (-) . kt
Distance : . nm
2) Indicate of the trip distance
Data block format Trip distance : . nm
1) at normal operation 3) Indication of the longitudinal transverse speed
(for dual-axis)
longitudinal speed : (-) . kt
2) When the system error is detected Transverse speed : S/P . kt

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


6
4) Indicating of the resultant speed and detection - Digital display LR221
(for dual-axis) Selected and displayed the speed and distance by pressing
Resultant speed : (-) . kt “Select” button.
Direction : deg (relative direction) - Power : 100V to 230V AC
5) Indication of GPS speed data - Input signal : RS422
It is indicated ship’s speed, total distance traveled and - Display form
trip distance by speed data from GPS. Speed : (-) . kt
6) Indication of alarm Distance : . nm
- Display : Liquid crystal (LCD) 7 segment
The error messages detected by self diagnostic
- Illumination : Facet illumination LED
function are indicated.
- Dimmer : Push button (Not install external)
- In the first stage adjustment, manual key-in and
- Installation : Flash mount or Desk top type
maintenance
- Wiring position : Grand with water resist (bracket type) or
Possible to set manual speed, zero adjustment, milepost terminal (flush mount type)
measurement, and also to confirm of various data.
- Dimmer LED : LED lamps are added and subtracted Sea-bottom (Sensor)
by buttons. - HS1 type : Using the Φ35 sensor, and installed at
- Input signal : Digital signal(NMEA0183) single or double bottom of ship. Standard
Input voltage 24V DC length of protraction is 50mm.
- Wiring position : Coaming of under or back - Sensor : Outside diameter : Φ35, length : 400mm
- Installation : Desk-top, Wall mount or Flash mount with cable (7m/15m)
- Construction : Water resist type - Seawater valve : 40A JIS5K Gate valve

- HD1 type : Using theΦ35 sensor, and installed with


- Junction box LN052 penetration double bottom. Seawater
The junction box is used for connection between sensor and valve is installed on inner sea-bottom.
master unit. And it is connected by maker supply cable and Standard length of protraction is 50mm.
ship-builder supply cable. - Sensor : Outside diameter : Φ35 with rodmeter
- Installation : Wall mount (connected by connecter)
- Seawater valve : 40A JIS5K Gate valve
- Wiring position : Ground with water resist
- Protection tube/seawater valve :
Water resist that the sensor and rodmeter go through
- Speed indicator LR524(Single-axis) / LR525 (Dual-axis)
double bottom.
This is a large analog indicator with an outside diameter of
180mm. - FA1/FA2 type : Using theΦ48 sensor, and installed at
The indicative variation are speed, longitudinal / transverse single bottom of ship. Standard length of
speed (for dual-axis) and resultant speed /direction. And the protraction 1s 13mm or 73mm. FA2 is for
scale boards are prepared 18 kinds include each dual-axis.
measurement range. - Sensor : Outside diameter : Φ48, length 345mm
- Power supply : 24V DC 0.3A (7.5W) - Seawater valve : 50A JIS5K ball valve
- Capacity : 4 circuits max. - HV1/HV2 type : Using theΦ70 sensor, and installed at
However, the forth is necessary to have single bottom of ship. Standard length of
the power supply of 24V DC from protraction is 7mm or 50mm. HV2 is for
external. dual-axis.
- Input signal : Digital signal - Sensor : Outside diameter : Φ70, length 510mm
- Illumination : EL board or LED illumination - Seawater valve : 75A JIS5K ball valve
- Dimmer : Built-in or external
- Wiring position : Back part - RD1 type : With air cylinder unit for remote operation
- Instauration : Flash mount or Wall mount protraction length of the sensor.
- Construction : Type of water resist Using theΦ35 sensor, and installed with
penetration double bottom. Seawater
valve is installed on inner sea-bottom.
- Dimmer box LD001A
- Sensor : Outside diameter : Φ35 with rodmeter
For LR524 / LR525
(connected by connecter)
- Power supply : 100V to 115V or 200V to 230V AC
- Seawater valve : 40A JIS5K Gate valve
- Wiring position : Corming
- Protection tube/seawater valve :
- Instauration : Flash mount or Wall mount
Water resist that the sensor and rodmeter go through double
bottom.

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


7
Type No. and Suffix code
Master unit LT501-X1 ・・・ X7/Option Master indicator LR523-X1 ・・・ X5/Option
Type No. Suffix code Note Type No. Suffix code Note
LT501 ・・・・・・・・・・・・・・・・・・・・ For EML500 LR523 ・・・・・・・・・・・・・・・・・・・・ For EML500
Style −F Flush mount Style −D Flush mount
−W Wall mount −F Flush mount (with bezel)
X1 −Y Wall mount (with coaming plate) X1 −W Desk top type or Wall mount
System 1 Single-axis System 1 Single-axis
X2 2 Dual-axis (Note 1) X2 2 Dual-axis
Ship’s power 1 100V AC 50/60Hz 1Φ Rule / Name plate 1 None / Japanese & English
2 110V AC 50/60Hz 1Φ 2 JG / Japanese & English
3 115V AC 50/60Hz 1Φ 3 JG / Japanese
4 200V AC 50/60Hz 1Φ 4 None / English
X3 5 220V AC 50/60Hz 1Φ 5 MED / Japanese & English (Note 1)
Measurement range 1 − 4kn to 20kn X3 6 MED / English (Note 1)
2 − 5kn to 25kn Color X4 −1 YDK Standard (CC24 brown)
3 − 7kn to 35kn Name plate −1 HS1
4 − 8kn to 40kn −2 HD1
5 −10kn to 50kn (Note 2) −3 HV1
X4 6 −13kn to 65kn (Note 2) −4 HV2
Rule / Name plate 1 None / Japanese & English −5 FA1
2 JG / Japanese & English −6 FA2
3 JG / Japanese X5 −7 RD1
4 None / English Option /CHS Name plate in Chinese
5 MED / Japanese & English (Note 3) (Note 1) MED is attended in case of System X2 = 1 (Single-axis).
X5 6 MED / English (Note 3)
Color 1 YDK Standard (CC24 brown) Speed indicator (Dual axis) LR525-X1 ・・・ X9/Option
Type No. Suffix code Note
2 Munsell 2.5G7/2
LR525 ・・・・・・・・・・・・・・・・・・・・ For EML500 (Dual-axis)
X6 3 Munsell 7.5BG7/2
Name plate −1 HS1 Style −F Flush mount

−2 HD1 X1 −W Desk top type or Wall mount

−3 HV1 Measurement range 1 − 4kn to 20kn (Note 1)

−4 HV2 2 − 5kn to 25kn

−5 FA1 3 − 7kn to 35kn

−6 FA2 4 − 8kn to 40kn

X7 −7 RD1 5 −10kn to 50kn

Option /AN1 Alarog output (Connect LR522) X2 6 −13kn to 65kn

/AN5 Analog output Scale plate 1 Longitudinal / Transverse speed

/ANF1 Analog output X3 2 Resultant speed /Direction

/ANF5 Anarog output (0V to 5V DC output) Illumination −A LED Orange color


/CHS Name plate in Chinese −B LED Green color
/GPS External speed signal input (Note 4) −G EL board Green color

(Note 1) In case of dual-axis, transverse speed may not be able to the mounting −N Illumination not use
position of sensor. X4 −R EL board Orange color
(Note 2) About 50/60kt correspondence, additional engineering is required concerning Dimmer / Power supply 1 External/100V to 115V AC 50/60Hz 1Φ
the installation of the sensor.
(Note 3) MED is attended in case of System X2 = 1 (Single-axis) and X4 = 1 2 (Note 2) Built-in /100V to 115V AC 50/60Hz 1Φ
(-4kn to 20kn) or X4 = 2 (-5kn to 25kn) 3 External/200V to 230V AC 50/60Hz 1Φ
(Note 4) Please append external speed signal (NMEA0183) format with order sheet. 4 (Note 2) Built-in /200V to 230V AC 50/60Hz 1Φ
5 External/LED illumination
6 Built-in /LED illumination
X5 N Illumination not use
Wiring position 1 Cormingφ25
X6 2 Grand (Note 3)
Rule / Name plate 1 None / Japanese & English
2 JG / Japanese & English
3 JG / Japanese
X7 4 None / English
Color 1 YDK Standard (CC24 brown)
2 Munsell 2.5G7/2
X8 3 Munsell 7.5BG7/2
Name plate −1 HV2
X9 −2 FA2
Option /CHS Name plate in Chinese
(Note 1) Case of Resultant speed /Direction are not indicate (-) data. Indicate
0 to XX kt.
(Note 2) X5 = 2 and X5 = 4 are use for LR525 built-in dimmer unit only.
(Note 3) X6 = 2 Grand is use for Wall mount only. (15b, 20c each 1 use)

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


8

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


9
LR523-W Master indicator (Wall mount)

LR523-D Master indicator (Flash mount)

Outline
LN052 Junction box

24V 1
GND 2
FG 3
RDA 4
RDB 5
SDA 6
SDB 7
N.C 8

YSPD A LR523-F Master indicator (Flash mount)


XSPD B
GND-S E
G
+15V C
-15V D
24V-S F

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


10
LT501-W Master unit (Wall mount) LT501-Y Master unit
(Wall mount : with corming plate)

LT501-F Master unit (Flash mount) Terminal drawing

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


11
LR524-W Analog indicator (Wall mount) LR525-W Analog indicator (Wall mount)
(Power supply 100V to 115VAC) (Power supply 200V to 230VAC)
Single-axis Dual-axis

LR524-F Analog indicator (Flash mount) LR525-F Analog indicator (Flash mount)
(Power supply 100V to 115VAC) (Power supply 200V to 230VAC)
Single-axis Dual-axis

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


12
Scale plate list LD001A-F Dimmer box (Flash mount type)
- Single : -4kt to 20kt - Single : -5kt to 25kt (Connection diagram is for EL board)

- Single : -7kt to 35kt -Single : -8kt to 40kt

- Single : -10kt to 50kt -Single : -13kt to 65kt

- Dual : - Dual :
resultant speed /direction longitudinal / transverse speed

LD002 Dimmer switch


(Connection diagram is for LED illumination)
LD001A-W Dimmer box (Wall mount type)
(Connection diagram is for EL board)

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12


13
LR221-D Digital display (Desk-top type) LR221-D Digital display (Flash-mount type)

Yokogawa Denshikiki Co.,Ltd. GS80B80M01E 7th 2002-12