Piping Details: Norsok Standard
Piping Details: Norsok Standard
Piping Details: Norsok Standard
COMMON REQUIREMENTS
PIPING DETAILS
L-CR-003
Rev. 1, January 1996
Please note that whilst every effort has been made to ensure the accuracy of the NORSOK standards
neither OLF nor TBL or any of their members will assume liability for any use thereof.
Piping details L-CR-003
Rev. 1, January 1996
CONTENTS
1 FOREWORD 2
2 SCOPE 2
3 NORMATIVE REFERENCES 2
4 DEFINITIONS AND ABBREVIATIONS 2
4.1 Definitions 2
4.2 Abbreviations 2
5 TECHNICAL REQUIREMENTS 2
5.1 General 2
5.2 Options 3
5.3 Double block 3
5.4 Modular compact valves 3
5.5 Valve legend 3
5.6 Drilling details 4
5.7 Hydraulic 4
5.8 Birdscreen 4
ANNEX A TYPICAL DRAWINGS (NORMATIVE) 5
1 FOREWORD
NORSOK (The competitive standing of the Norwegian offshore sector) is the industry initiative to
add value, reduce cost and lead time and remove unnecessary activities in offshore field
developments and operations.
The NORSOK standards are developed by the Norwegian petroleum industry as a part of the
NORSOK initiative and are jointly issued by OLF (The Norwegian Oil Industry Association) and
TBL (The Federation of Norwegian Engineering Industries). NORSOK standards are administered
by NTS (Norwegian Technology Standards Institution).
The purpose of this industry standard is to replace the individual oil company specifications for use
in existing and future petroleum industry developments, subject to the individual company's review
and application.
The NORSOK standards make extensive references to international standards. Where relevant, the
contents of this standard will be used to provide input to the international standardization process.
Subject to implementation into international standards, this NORSOK standard will be withdrawn.
2 SCOPE
The standard defines the installation requirements for piping details.
3 NORMATIVE REFERENCES
NORSOK L-CR-001 Piping and valves
4.1 Definitions
Normative references Shall mean normative in the application of NORSOK standards.
Informative references Shall mean informative in the application of NORSOK standards.
Shall Shall is an absolute requirement which shall be followed strictly in order
to conform with the standard.
Should Should is a recommendation. Alternative solutions having the same
functionality and quality are acceptable.
May May indicates a course of action that is permissible within the limits of
the standard (a permission).
Can Can-requirements are conditional and indicates a possibility open to the
user of the standard.
4.2 Abbreviations
ASME American National Standards Institute
5 TECHNICAL REQUIREMENTS
5.1 General
This document is based upon using components from L-CR-001. However, components not covered
in L-CR-001 may be handled as special items.
5.2 Options
This standard contains individual piping details. It is the intention that each project shall compile a
set of standard sheets from this document applicable for the particular project.
Undesired sheets and options (E.g. 10A or 10B) should be subtracted by the project.
Check valve
5.7 Hydraulic
Hydraulic related piping is not included in this revision.
5.8 Birdscreen
Use standard flanges for optional closure solutions during construction.
For larger sizes, if no pressure testing is required, consider use of other closure solutions for weight
reduction.
VESSEL TRIM LEVEL TRANSMITTER (D.P. INTRUSIVE TYPE) 024 150 TO 2500
STILLING TUBE FOR ATM. TANK LEVEL TRANSM. (TOP ACCESS) 030 150
ORIFICE FLANGE WITH FLAT AND RAISED FACE 040 150 TO 300
SAMPLE CONNECTION FOR PROCESS GAS/LIQUID SERV. (HAZ. FLUID) 070 150 TO 2500
SAMPLE CONNECTION FOR UTILITY SERVICES (NON-HAZ. FLUID) 071 150 TO 2500
INLINE CONDENSATE DRAIN POINTS FOR STEAM MAINS 093 150 TO 2500
END OF MAIN CONDENSATE DRAIN POINTS FOR STEAM MAINS 094 150 TO 2500
min
min
LINE SIZE 1.5" TO 3"
WITHDRAWAL SPACE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. For installation in vertical lines use concentric buttweld reducers and 45° latroflange if required.
3. The Thermowell must be purchased to fit the inside diameter of the reinforced nipoflange which shall be machined
according to the nominal inside diameter of the corresponding piping class.
4. Weldolet, nipple and flange to piping class may be used as an alternative to reinforced nipoflange where this can be
documented to be more cost effective.
THERMOWELL CONNECTIONS PD-001 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
MINIMUM 250 MM FREE SPACE TEMPORARY PLUG
1/2" NPT
100 NOTE 2
Ø 35
Ø 6.5 5 MM CONTINUOUS
FILLET WELD TO
INSTRUMENT BE WITHIN PIPING
SCOPE OF WORK
PIPING
NOTES:
1. Material grade to be compatible with pipe & fittings.
2. Insulation thickness must be considered.
EXTERNAL THERMOWELL CONNECTION PD-004 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
TEMPORARY PLUG
INSTRUMENT 3/4" GATE VALVE BW ONE END
PIPING THREADED OTHER END
HORIZONTAL LINES
NOTE 4
45°
MAXIMUM
45°
MAXIMUM
GAS LIQUID
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. -
3. For bracing details, see PD-059.
4. For vertical lines add elbow to achieve correct vertical orientation of instrument.
INSTRUMENT PRESSURE CONNECTION (WELDED) PD-010A Sht 1 of 1 Rev. 02
CL 150 TO CL 300
TEMPORARY PLUG
INSTRUMENT THR. RED. FLG 0.75” X 0.5” NPT (F)
PIPING
3/4" GATE VALVE FLANGED BOTH ENDS
3/4" FLANGE
HORIZONTAL LINES
NOTE 4
45°
MAXIMUM
45°
MAXIMUM
GAS LIQUID
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. -
3. For bracing details, see PD-059.
4. For vertical lines add elbow to achieve correct vertical orientation of instrument.
INSTRUMENT PRESSURE CONNECTION (FLANGED) PD-010B Sht 1 of 1 Rev. 02
CL 150 TO CL 300
TEMPORARY PLUG
INSTRUMENT
3/4" GLOBE VALVE BW ONE END
PIPING
THREADED OTHER END
HORIZONTAL LINES
NOTE 4
45°
MAXIMUM
45°
MAXIMUM
GAS LIQUID
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. -
3. For bracing details, see PD-059.
4. For vertical lines add elbow to achieve correct vertical orientation of instrument.
INSTRUMENT PRESSURE CONNECTION (WELDED) PD-011A Sht 1 of 1 Rev. 02
CL 600 TO CL 2500
INSTRUMENT
PIPING 3/4" GLOBE VALVE FLANGED
3/4" FLANGE
HORIZONTAL LINES
NOTE 4
45°
MAXIMUM
45°
MAXIMUM
GAS LIQUID
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. -
3. For bracing details, see PD-059.
4. For vertical lines add elbow to achieve correct vertical orientation of instrument.
INSTRUMENT PRESSURE CONNECTION (FLANGED) PD-011B Sht 1 of 1 Rev. 02
CL 600 TO CL 2500
TEMPORARY PLUG
INSTRUMENT
3/4" GATE VALVE BW ONE EN
THREADED OTHER END
2" FLANGE WN
VESSEL
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
INSTRUMENT PRESSURE CONNECTION TO VESSEL PD-014 Sht 1 of 1 Rev. 02
(WELDED), CL 150 TO CL 300
TEMPORARY PLUG
INSTRUMENT
3/4" GLOBE VALVE BW ONE END
THREADED OTHER END
2" FLANGE WN
VESSEL
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
INSTRUMENT PRESSURE CONNECTION TO VESSEL PD-015 Sht 1 of 1 Rev. 02
(WELDED), CL 600 TO CL 2500
VESSEL/ NOTE 6
BRIDLE PIPING
NOTE 5
1/2" NPT HEX HEAD PLUG
0.75" x 1/2" NPT RED. FLANGE
3/4" NIPPLE BOE/TOE &
0.75" GATE VALVE
0.75" WN FLANGE (TYP.)
NOTE 3
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Use ecc. reducers field welded to allow for alignment.
3. Nipples to be seal welded by level gauge vendor for HC services only.
4. Provide break flanges down stream first isolation valve when piped to drain/flare.
5. Use double block for ANSI class 600 and above.
6. Split between piping and instrument to be decided by project.
VESSEL TRIM LEVEL GAUGE PD-020 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
1/2" NPT HEX HEAD PLUG
0.75" x 1/2" NPT RED. FLANGE
PIPING 0.75" GATE VALVE
INST. 0.75"
VESSEL PIPING
NOTE 3
2" GATE VALVE (TYP.)
NOTE 3
0.75"
INST.
PIPING
0.75"
0.75" GATE VALVE
0.75" x 1/2" NPT RED. FLANGE NOTE 4
1/2" NPT HEX HEAD PLUG
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Introduce 2" flanges, elbow and pipe to reduce overall standout and provide for adjustment if necessary.
3. Use double block for ANSI class 600 and above.
4. Provide break flanges down stream first isolation valve when piped to drain/flare.
VESSEL TRIM LEVEL TRANSMITTER PD-022 Sht 1 of 1 Rev. 02
(FLOAT TYPE), CL 150 TO CL 2500
Flanged pressure sensing
INSTRUMENT Drip
PIPING
2" Double block
NOTE 5
bleed valve
PIPING
VESSEL
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Introduce 2" flanges, elbow and pipe to reduce overall standout and provide for adjustment if necessary.
3. Check P&ID for any hard pipe requirements to closed drain/flare.
4. Provide break flanges downstream first isolation valve when piped to drain.
5. Location on vessel to be advices by instrument.
6. Support (if required) to be designed by support group.
VESSEL TRIM LEVEL TRANSMITTER (D.P.), PD-023 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
F la n g e d p re s s u r e s e n s in g
IN S T R U M E N T
D rip r in g
P IP IN G
2 " D o u b le b lo c k
& b le e d v a lv e a s s e m b ly
P IP IN G V E S S E L
NO TE 5
2 " D o u b le b lo c k &
b le e d v a lv e
D rip r in g
D P c e ll
L in e s lo p e d 1 0 °
to w a r d s v e s s e l
N o te 5
VESSEL P IP IN G IN S T R U M E N T
NO TE 3 & 4
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Introduce 2" flanges, elbow and pipe to reduce overall standout and provide for adjustment if necessary.
3. Check P&ID for any hard pipe requirements to closed drain/flare.
4. Provide break flanges downstream first isolation valve when piped to drain.
5. Location on vessel to be advices by instrument.
6. Support (if required) to be designed by support group.
VESSEL TRIM LEVEL TRANSMITTER PD-024 Sht 1 of 1 Rev. 02
(D.P. INTRUSIVE TYPE), CL 150 TO CL 2500
INSTRUMENT
3"or 4” WN FLANGE
6"OR 4” PIPE
150
WELD TO TANK BOTTOM
TANK BOTTOM
OPEN PIPE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Hole in blind flange for sensing unit to be drilled and tapped by instrument.
STILLING TUBE FOR ATMOSPHERIC TANK PD-030 Sht 1 of 1 Rev. 02
LEVEL TRANSMITTER (TOP ACCESS), CL150
SPECIAL FULL BORE BALL VALVE
INSTRUMENT
PIPING
500
2" NOZZLE
NOTE 2 & 3
STILLING WELLTO
BE SUPPORTED IF
APPROX. NECESSARY
100
NOTE 4
APPROX. 100 x 10 MM
SLOTS IN 2” PIPE
50
OPEN PIPE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Nozzle to be provided with a stilling well of equal I.D. over the full height of tank.
3. Bolts, nuts & gaskets by piping.
4. Slot to be located as close to tank top as possible.
ATMOSPHERIC TANK MANUAL LEVEL LOGGING PD-031 Sht 1 of 1 Rev. 02
CONNECTING POINT, CL 150
45° MAX
(TYP)
45° MAX
(TYP)
INSTRUMENT
PIPING PIPING
1/2" RF
1/2" NIPPLE BOE/TOE 100 MM LONG NOTE 4.
FLOW
NOTES:
1. Rating and material grade of nipples and valves to be the same as for the flow elements and relevant piping class.
2. If double tapping is required, taps must be offset or extended to avoid clash of tap flanges and valves.
3. For vertical lines add 45° elbow and additional nipple between orifice flange and valve to achieve vertical
orientation.
4. Alternatively use nipoflange if feasable.
ORIFICE FLANGE WITH FLAT AND RAISED FACE PD-040 Sht 1 of 1 Rev. 02
CL 150 TO CL 300
45° MAX
(TYP)
45° MAX
(TYP)
FLOW
NOTES:
1. Rating and material grade of nipples and valves to be the same as for the flow elements and relevant piping class.
2. If double tapping is required, taps must be offset or extended to avoid clash of tap flanges and valves.
3. For vertical lines add 45° elbow and additional nipple between orifice flange and valve to achieve vertical
orientation.
ORIFICE FLANGE WITH RTJ FLANGES PD-041 Sht 1 of 1 Rev. 02
CL 600 TO CL 2500
B L IN D F L A N G E
B L IN D F L A N G E
G A T E V A LV E FLG D
G A T E V A LV E FLG D
W N FLA N G E
R E IN F O R C E D NOTE 4
N IP O F L A N G E
P IP E (B B E ) 1 0 0 M M L O N G
NOTE 3 NOTE 4
E Q /R E D . T E E A S P E R
B R A N C H S P E C IF IC A T IO N
B L IN D F L A N G E B L IN D F L A N G E
G LO BE V A LV E FLG D G LO BE V A LV E FLG D
G A T E V A LV E FLG D G A T E V A LV E FLG D
W N FLA N G E
R E IN F O R C E D NOTE 4
P IP E (B B E ) 1 0 0 M M L O N G N IP O F L A N G E
NOTE 4
NOTE 3
E Q /R E D . T E E A S P E R
B R A N C H S P E C IF IC A T IO N
H E A D E R S IZ E S 0 .5 " - 1 " H E A D E R S IZ E S 1 .5 " A N D A B O V E
VENTS & DRAINS FOR LINE SIZE 3/4" TO 12" TO BE 3/4" SIZE
VENTS & DRAINS FOR LINE SIZE ABOVE 12" TO BE 1" SIZE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. -
3. Cut to suit.
4. For bracing see PD-059.
5. When clearance between face of valve/top of deck or ceiling is less than 200mm, use PD-050B.
LOCAL VENT & DRAIN (ALTERNATIVE 1) PD-050A Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
BLIND FLANGE
WN FLANGE
WN FLANGE
90° ELBOW
REINFORCED NOTE 4
NIPOFLANGE
PIPE (BBE) 100 MM LONG
NOTE 3 NOTE 4
BLIND FLANGE
90° ELBOW
WN FLANGE
NOTE 4
GLOBE VALVE FLGD REINFORCED
NOTE 4
PIPE (BBE) 100 MM LONG NIPOFLANGE
NOTE 3
VENTS & DRAINS FOR LINE SIZE 3/4" TO 12" TO BE 3/4" SIZE
VENTS & DRAINS FOR LINE SIZE ABOVE 12" TO BE 1" SIZE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. -
3. Cut to suit.
4. For bracing see PD-059.
LOCAL VENT & DRAIN (ALTERNATIVE 2) PD-050B Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
BLIND FLANGE
WN FLANGE
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. For bracing details, see PD-059.
HYDROSTATIC PRESSURE TESTING PD-055 Sht 1 of 1 Rev. 02
VENT & DRAIN, CL 150 TO CL 2500
MIN MAX MIN
50 100 50 MIN
50
A
PAD
A NOTE 2&4
MIN 50
PAD
NOTE 2&4 25x25x4 MM
ANGLE IRON
25x25x4 MM NOTE 3
ANGLE IRON
HEADER SIZE 2" AND ABOVE
MIN MAX MIN
100
Pipe or pad
PAD
NOTE 2&4 ANGLE IRON TO BE
25x25x4 MM CUT IN BOTH ENDS
ANGLE IRON
DRILLED AND CUT
TO SUIT FIXING AT FLANGE PAIR
BACK OF FLANGE
NOTES:
FE
INSTRUMENT
PIPING
150
165 FOR CL 2500 2" REINFORCED NIPOFLANGE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Annubar supporting is only applicable where specified on instr. data sheet.
3. The probe must be purchased to fit the inside diameter of reinforced nipoflange which shall be machined according
to the nominal inside diameter of the corresponding piping class.
4. Mounting position to be verified by process.
5. Space requirement to be specified/verified by instrument department for individual case.
ANNUBAR CONNECTIONS PD-060 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
1000
CHOKE
CHOKE
FLOW 1820
FLOW
INSTRUMENT NOTE 5
PIPING
150
165 FOR CL 2500 2" REINFORCED NIPOFLANGE
5 x ID MIN. 5 x ID MIN.
10 x ID OPTIM. 10 x ID OPTIM.
MAX. 15°
NOTE 2.
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Mounting position: Top mounting prefered.
3. The probe must be purchased to fit the inside diameter of reinforced nipoflange which shall be machined according
to the nominal inside diameter of the corresponding piping class.
4. Space requirement, straight pipe requirement and distance from choke valves to be specified/verified by instrument
department for individual case.
5. Reinforced nipoflange as an integral part of a complex instrument assembly is acceptable.
ACCESS FITTING FOR SAND PROBE PD-061 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
1000
1500
NOTE 4
INSTRUMENT NOTE 6
PIPING
150
165 FOR CL 2500
2" REINFORCED NIPOFLANGE
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. The probe must be purchased to fit the inside diameter of reinforced nipoflange which shall be machined according
to the nominal inside diameter of the corresponding piping class.
3. Mounting position: Any position, piping to decide.
4. Space requirement and straight pipe requirements to be specified/verified by instrument department for individual
case.
5. Transverse space requirements: 500mm each side.
6. Reinforced nipoflange as an integral part of a complex instrument assembly is acceptable.
ACCESS FITTING FOR CORROSION MONITORING PD-062 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
USE STD SPADE WITH HOLE 2" WELDOLET
TO CARRY SAMPLE QUILL
2" WN
2" x 0.75" RED.
SAMPLING P = 1/3 x D
STATION
MARK ON
FOR FLOW DIRECTION
INSTR. PIPING Q
u
i
l
l 1/2" PIPE END CUT
Spade 45° FACING UPSTREAM
FULL PENETRATION
WELD AS SHOWN
SUPPORT
AS ABOVE GRIND TO
3 OFF AT
2" CONNECTION TO HEADER
AS PER BRANCH TABLES OR
TO CLOSED DRAIN/FLARE
SYSTEM AS PER P&ID
For header sizes 4" and below use 2" connection as per branch table and without quill.
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. Preferred location in vertical lines.
3. Instrument and process departments to specify/verify sample probe details, nozzle orientation, special materials, 45°
end etc.
4. Support, if needed, by site.
5. Insulation and heat tracing to be introduced upstream sampling station if required.
SAMPLE CONNECTION FOR PROCESS GAS/LIQUID PD-070 Sht 1 of 1 Rev. 02
SERVICES (HAZARDOUS FLUID), CL 150 TO CL 2500
2" WELDOLET
USE STD SPADE WITH
TO CARRY SAMPLE QUILL
2" FLANGE
2" x 0.75" RED.
P = 1/3 x D
NOTE 5
MARK ON HANDLE
FOR FLOW DIRECTION
INSTR. PIPING
45°
MAXIMUM
For header sizes 4" and below use 2" connection as per branch table and without quill.
NOTES:
1. Rating and material of all items to be according to the relevant piping class.
2. Preferred location in vertical lines.
3. Instrument and process departments to specify/verify sample probe details, nozzle orientation, special materials, 45°
end etc.
4. Support, if needed, by site.
5. Extra gate valve required at low point if no access to header.
6. Sampling line to be heat traced and insulated if required.
SAMPLE CONNECTION FOR UTILITY SERVICES PD-071 Sht 1 of 1 Rev. 02
(NON-HAZARDOUS FLUID), CL 150 TO CL 2500
G
STRUCTURAL CONICAL BODY:
PERFORATED PLATE (THICKNESS "T") 10 RAD.
HOLES 5MM DIA ON TRIANGULAR PITCH OF 8MM
GIVING 35.4% OPEN AREA
4"
EXTERNAL FILTER SCREEN: NOTE 8 300 LB
F
FLOW
C
A B
E D E NOTE 7
FLOW
Min. D + 100 MM
Nom A B C D F G L T
Size Class Class
(in) 150 300
2 102 108 35 20 125 70 25
3 132 146 68 30 180
4 170 178 92 40 220 30 2
6 218 248 140 60 320 80
8 276 304 186 80 400 35
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. Dimensions in millimetres.
3. Pipe size and flange class to be clearly die stamped on handle e.g. 6" - class 150.
4. Only the side wall of the cone is perforated.
5. Filter screen to be located on upstream side of cone and shall be securely welded or braced to cone. Filter may be
subject to pulsating flow and flow reversal.
6. Surface finish of gasket contact areas to be according to ANSI B16.5.
7. Thickness E according to element data sheet NLB1 of the NORSOK standard Piping and valves (L-CR-001).
8. Filter screen mesh to be based on requirements from relevant connected equipment. (i.e compressor)
TEMPORARY "CONICAL" STRAINER PD-080 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
STANDARD TEE TO PIPING CLASS (1)
STIFFENERS: 20mm x 5mm (2) SEAL PLATE: 5mm (2) GUIDE ROD (2)
15
FLOW
L
MAX GAP 0.5mm
A A
L (ACTUAL) + 1mm
ROD 10 mm
NOTES:
1. Rating and material grade of pipe, fittings and parts shall be in accordance with the relevant piping class.
2. All materials of bathtub to be stainless steel, type 316.
3. Filter screen mesh to be based on requirements from relevant connected equipment (i.e compressor).
4. Dimension L and radius R to be determined by vendor from dims. of BW tee and flanges stated by purchaser.
5. Bolt lengths to account for bolt tensioning.
6. Strainer will be subject to pulsating flow, and must be capable of withstanding reversed flow.
7. Details shown are for piping layout and manufacturers guidance only. Fabricator to supply full dimensional and
fabrication detail drawings.
8. Drain/inspection nozzle according to the relevant piping class. Drain to be located at low point if side mounted.
9. Differential pressure measurement to be installed as required by P&ID.
TEMPORARY "BATH TUB" STRAINERS 10"-24" NPS PD-081 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
22 DIA. GREASE NIPPLE
20 DIA.
150 R =230
90
D
50
10
C 60
150
10 35 B
35
175
130
NOTE 4 20 115
A E F 215
SOLID BAR
10 406 300 573 42 85.0 2" SCH 160 444 322 593 44 76.4 2½" SCH 80
12 483 340 613 42 81.0 2" SCH 160 521 360 630 44 73.7 2½" SCH 80
14 533 365 638 42 79.6 2" SCH 160 584 392 663 44 71.9 2½" SCH 80
16 597 397 670 42 77.9 2" SCH 160 648 425 695 44 70.5 2½" SCH 80
18 635 415 688 42 77.1 2" SCH 160 711 457 728 44 6.4 2½" SCH 80
20 698 447 720 44 69.6 2½ SCH XXS 775 487 758 44 68.5 2½" SCH 80
24 813 505 778 44 68.0 2½ SCH XXS 915 557 828 48 73.3 2" SCH 80
30 984 592 862 48 74.6 2" SCH 80 1092 648 916 72 57.6 3" SCH 80
36 1168 685 954 58 57.2 3" SCH XXS
SIZE CLASS 600 LB CLASS 900 LB
(in)
A B C D E F A B C D E F
10 508 360 624 48 80.3 2" SCH 80 546 378 643 58 65.0 3" SCH XXS
12 559 385 650 48 78.9 2" SCH 80 610 412 675 58 63.4 3" SCH XXS
14 603 408 673 48 77.8 2" SCH 80 641 430 690 58 62.7 3" SCH XXS
16 686 448 713 48 76.2 2" SCH 80 705 462 723 58 61.6 3" SCH XXS
18 743 479 743 48 75.3 2" SCH 80 787 505 763 58 60.4 3" SCH XXS
20 813 515 778 48 74.4 2" SCH 80 857 540 798 58 59.6 3" SCH XXS
24 940 580 840 58 58.8 3" SCH XXS 1041 640 890 72 58.0 3" SCH 80
SIZE CLASS 1500 LB CLASS 2500 LB
(in)
A B C D E F A B C D E F
10 584 410 663 72 63.9 3" SCH 80
12 673 460 708 72 62.1 3" SCH 80
14 749 500 745 72 60.9 3" SCH 80
16 825 542 783 72 59.9 3" SCH 80
18 914 590 828 72 59.0 3" SCH 80
20 984 628 863 85 52.0 3½" SCH 80
24 1168 726 955 90 50.8 3½" SCH 80
NOTES:
1. Flange material grade as per the relevant piping class. Rods and plates welded to flanges shall be of identical
material grade as the flanges.
2. All other parts shall be carbon with min. yield strength 220 MPa.
3. Eyebolt and nuts to be hot dip galvanised.
4. Drain/inspection nozzle according to the relevant piping class.
5. Details shown are for fabricators guidance. Other solutions with similar or higher strength and functional properties
are acceptable.
DAVIT FOR BLIND FLANGE PD-085 Sht 1 of 1 Rev. 02
CL 150 TO CL 2500
O ROD F
1 x 45°
GASKET CONTACT
FACE
SEE NOTE 4 50
C E
50
20.7 15.6
1 45°
NOTE 6 NOTE 5
G
1
2
1" 3/4"
B DIA 1 WELDING NIPPLE
41 DIA 33.4 DIA
SEE DETAIL
BELOW NOTE 6 NOTE 5
A DIA
45°
40
FLANGE WN 60°
SCH. 160
90 ROUNDED
33.4 26.7
NOTE 6 NOTE 5
35°
20.7 15.6
NOTE 6 NOTE 5
Nominal A B C E F G O
pipe size Class Class
150 300
2" 102 108 60 40 180 38 4 6
3" 133 146 89 40 185 38 4 10
4" 171 178 114 40 190 38 4 10
6" 219 247 168 40 200 38 4 10
8" 276 305 219 40 210 38 4 10
10" 337 359 273 40 235 38 4 10
12" 406 419 324 60 248 58 5 16
14" 448 483 356 60 260 58 5 16
16" 511 536 406 60 267 58 5 16
18" 546 594 457 60 279 58 5 16
20" 603 651 508 70 286 68 5 16
24" 714 772 610 70 317 68 5 16
NOTES:
1 x 45°
G A SK E T C O N T A C T
FA C E
SE E N O T E 4 50
E
C
50
20 .7 15 .6
1 45 °
NOTE 6 NOTE 5
G
1
2
B D IA 1 W E L D IN G N IPP L E
41 D IA 33 .4 D IA
SE E D E T A IL
BE LOW NOTE 6 NOTE 5
A D IA
45 °
40
FL A N G E W N 60 °
SC H . 1 60
90
RO UN D E D
33 .4 26 .7
NOTE 6 NOTE 5
35 °
20 .7 15 .6
NOTE 6 NOTE 5
Nominal A B C E F G O
pipe size Class Class Class
600 900 1500
2" 108 141 141 60 60 180 58 4 10
3" 146 166 173 89 60 185 58 4 10
4" 192 205 208 114 60 190 58 4 10
6" 265 287 281 168 75 200 72 7 16
8" 319 357 351 219 75 210 72 7 16
10" 399 434 434 273 75 235 72 7 16
12" 456 457 519 324 75 248 72 7 16
14" 491 520 579 356 75 260 72 7 16
16" 564 574 641 406 80 267 78 7 16
18" 612 638 702 457 80 279 78 7 16
20" 682 697 756 508 80 286 78 7 16
24" 790 837 900 610 90 317 88 7 16
NOTES:
FLOW
EQUAL TEE
1 x LINESIZE OR
MIN 100 MM FOR 1/2" THERMODYN.
STEAM TRAP, FLOW
3" AND SMALLER
FLANGED, WITH
BUILT IN STRAINER
1" WELDOLET
1" WN
REST OF DETAILS
1" GATE VALVE AS TO THE LEFT
WITH BLIND 1" x 1/2" SWAGE (TYP)
VISIBLE DISCHARGE TO
OR OPEN DRAIN BOX
Nominal L
pipe size (meters)
2" 70 DISTANCE BETWEEN DRAIN POINTS ON HEADERS
3" 60 L (MAXIMUM SPACING)
4" 50
6" 50
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. The above arrangement to be used in steam mains at intervals as in table and/or at the bottom of vertical up legs of
5 metres or more.
INLINE CONDENSATE DRAIN POINTS FOR PD-093 Sht 1 of 1 Rev. 02
STEAM MAINS, CL 150 TO CL 2500
1/2" AUTOMATIC
AIR RELEASE
VALVE
1" WN
1" WELDOLET
EQUAL
FLOW
1 x LINESIZE OR
MIN 100 MM FOR 1/2" THERMODYN.
STEAM TRAP,
3" AND SMALLER
FLANGED, WITH
BUILT IN STRAINER
VISIBLE DISCHARGE TO
OR OPEN DRAIN BOX
NOTES:
1. Rating and material grade of pipe and fittings shall be in accordance with the relevant piping class.
2. The above arrangement to be used at the end of steam mains for 6", 4" and 3" sizes only.
3. For use of automatic release valve, see P&ID.
END OF MAIN - CONDESATE DRAIN POINT FOR PD-094 Sht 1 of 1 Rev. 02
STEAM MAINS, CL 150 TO CL 2500
Inert Gas
100
1"
NOT SCALED
200
Plant Air
1"
200
Sea Water
Capped Ends 1"
Typ. 500
200 ½"
HP Cleaning
200
100
Scd NPT
Note 1.
350
Min.
Air Hose Reel
Note 3.
700
Flg'd
Sea Water
Hose Reel
Note 2.
700
Flg'd
HP Cleaning
Hose Reel
350
700
NOTES: