N070icg LD1
N070icg LD1
N070icg LD1
com
S P E C I F I C AT I O N
Customer:
Model Name: N070ICG-LD1
Date: 2012/04/09
Version: 01
Preliminary Specification
Final Specification
Approved by Comment
2 / 25
www.revo-sys.com
CHIMEI INNOLUX
REVISION HISTORY
3 / 25
www.revo-sys.com
CHIMEI INNOLUX
1. GENERAL DESCRIPTION
1.1 OVERVIEW
N070ICG-LD1 is a 7” (6.95” diagonal) TFT Liquid Crystal Display module with LED Backlight unit
and 39 pins LVDS interface. This module supports 1280 x 800 WXGA mode.
2. MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal (H) 160.8 161 161.2 mm
Vertical (V) 106.8 107 107.2 mm (1)
Module Size Thickness_ Top (T) - 2.5 2.7 mm
Thickness_ Bottom (T) - 4.26 4.46 mm
Thickness_ Bottom w/
4.39 4.59
Label(T)
Horizontal 151.46 151.76 152.06 mm
Bezel Area
Vertical 95.3 95.6 95.9 mm
Horizontal 149.46 149.76 150.06 mm
Active Area
Vertical 93.3 93.6 93.9 mm
Weight - 85 95 g
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
4 / 25
www.revo-sys.com
CHIMEI INNOLUX
3. ABSOLUTE MAXIMUM RATINGS (Note1)
Value
Item Symbol Unit Note
Min. Max.
Power voltage VCCS -0.3 5 V
Storage Temperature TST -20 +70 ºC (2)
Operating Ambient Temperature TOP -10 +60 ºC (2), (3)
Note (1): The absolute maximum rating values of this product are not allowed to be exceeded at any times.
A module should be used with any of the absolute maximum ratings exceeded, the characteristics
of the module may not be recovered, or in an extreme condition, the module may be permanently
destroyed.
Note (2) (a) 90 %RH Max. (Ta <= 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (3) The temperature of panel surface should be -10 ºC min. and 70 ºC max.
Relative Humidity
(% RH)
100
90
80
70
60
50
40
30
20
10
0
-50 -30 -10 10 30 50 70 90
Temperature (ºC)
5 / 25
www.revo-sys.com
CHIMEI INNOLUX
4. ELECTRICAL SPECIFICATIONS
4.1 FUNCTION BLOCK DIAGRAM
SCAN DRIVER IC
LVDS Display TIMING
Data & Clock CONTROLLER TFT LCD
H_Rev & V_Rev PANEL
INPUT
CE_EN
DC/DC CONVERTER &
CABC_EN
REFERENCE VOLTAGE
VCCS GENERATOR
CONNECTOR
GND
DATA DRIVER IC
DataEDID EDID
EEPROM
CLKEDID
VEDID
6 / 25
www.revo-sys.com
CHIMEI INNOLUX
28 H_Rev Reverse Scanning Display in Horizontal (2)
29 V_Rev Reverse Scanning Display in Vertical (2)
30 LED_GND LED Ground
31 LED_GND LED Ground
32 LED_GND LED Ground
33 NC No Connection (Reserve)
34 LED_PWM PWM Control Signal of LED Converter
35 LED_EN Enable Control Signal of LED Converter (3)
36 CABC_EN CABC Enable Input (3)
37 LED_VCCS LED Power Supply
38 LED_VCCS LED Power Supply
39 LED_VCCS LED Power Supply
Note (1) The first pixel is odd as shown in the following figure.
2,1 2,2
3,1
Pitch
Pitch
Ymax,
Ymax,1
Xmax
Note (2) The scanning display setting of H_Rev and V_Rev function are as follows.
Pin Hi Lo or Open
H_Rev From Right to Left in Horizontal From Left to Right in Horizontal
V_Rev From Bottom to Top in Vertical From Top to Bottom in Vertical
Hi = High level, Lo = Low level.
Note (3) The setting of CE/CABC function are as follows.
Pin Enable Disable
CE_EN Hi Lo or Open
LED_EN Hi Lo or Open
CABC_EN Hi Lo or Open
Hi = High level, Lo = Low level.
7 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.3 ELECTRICAL CHARACTERISTICS
4.3.1 LCD ELETRONICS SPECIFICATION
Value
Parameter Symbol Unit Note
Min. Typ. Max.
Power Supply Voltage VCCS 3.0 3.3 3.6 V (1)-
Ripple Voltage VRP - 50 - mV (1)-
CABC_EN, CE_EN High Level VIH (2.3) - (3.6) V
H_Rev, V_Rev
Input Voltage Low Level VIL (0) - (0.5) V
Inrush Current IRUSH - - 1.5 A (1),(2)
Mosaic - (249) (272) mA
Power Supply Current lcc
White - (273) (300) mA
Note (1) The ambient temperature is Ta = 25 ± 2 ºC.
Note (2) IRUSH: the maximum current when VCCS is rising
IIS: the maximum current of the first 100ms after power-on
Measurement Conditions: Shown as the following figure. Test pattern: black.
+3.3V
Q1 2SK1475
VCCS
C3
FUSE (LCD Module Input)
R1 1uF
47K
(High to Low)
(Control Signal)
Q2
R2
SW 2SK1470
1K
+12V
47K C2
VR1
C1
0.01uF
1uF
8 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.3.2 LED CONVERTER SPECIFICATION
Value
Parameter Symbol Unit Note
Min. Typ. Max.
LED Power Current LED_VCCS =Typ. ILED (83) (104) (125) mA (3)
LED_VCCS(Typ)
Q1 IRL3303
C3
FUSE (LED Converter Input)
R1 1uF
47K
(High to Low)
(Control Signal)
Q2
R2
SW=24V IRL3303
1K
LED_VCCS(Typ)
VR1 47K C2
C1
0.01uF
1uF
9 / 25
www.revo-sys.com
CHIMEI INNOLUX
VLED rising time is 0.5ms
0.5ms
90%
LED_VCC 0V 10%
LED_PWM 0V
100ms
LED_EN 0V
ILEDIS
ILEDRush
ILED
Note (2) If PWM control frequency is applied in the range less than 1KHz, the “waterfall” phenomenon on
the screen may be found. To avoid the issue, it’s a suggestion that PWM control frequency should
follow the criterion as below.
Note (3) The specified LED power supply current is under the conditions at “LED_VCCS = Typ.”, Ta = 25
± 2 ºC, fPWM = 200 Hz, Duty=100%.
10 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.3.3 BACKLIGHT UNIT
Ta = 25 ± 2 ºC
Value
Parameter Symbol Unit Note
Min. Typ. Max.
LED Light Bar Power
VL 22.5 26.1 27 V
Supply Voltage
(1)(2)(Duty100%)
LED Light Bar Power
IL 40 42 44 mA
Supply Current
Power Consumption PL 0.9456 1.096 1.21 W (3)
LED Life Time LBL 12000 - - Hrs (4)
Note (1) LED current is measured by utilizing a high frequency current meter as shown below :
VL ,IL
LED
Light Bar
Light Bar Feedback
Channels
Note (2) For better LED light bar driving quality, it is recommended to utilize the adaptive boost converter
with current balancing function to drive LED light-bar.
Note (3) PL = IL ×VL (Without LED converter transfer efficiency)
Note (4) The lifetime of LED is defined as the time when it continues to operate under the conditions at Ta =
o
25 ±2 C and IL = 20 mA(Per EA) until the brightness becomes 50% of its original value.
11 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.4 LVDS INPUT SIGNAL TIMING SPECIFICATIONS
4.4.1 LVDS DC SPECIFICATIONS
Value
Parameter Symbol Unit Note
Min. Typ. Max.
(1),
LVDS Differential Input High Threshold VTH(LVDS) - - +100 mV
VCM=1.2V
(1)
LVDS Differential Input Low Threshold VTL(LVDS) -100 - - mV
VCM=1.2V
LVDS Common Mode Voltage VCM 1.125 - 1.375 V (1)
Note (1) The parameters of LVDS signals are defined as the following figures.
VCM |VID|
Single Ended
0V
VTH(LVDS)
|VID|
Differential 0V
VTL(LVDS)
12 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.4.2 LVDS DATA FORMAT
CLK+
T/7
--- B7 B6 G7 G6 R7 R6
Rxin2 IN20 IN19 IN18 IN17 IN16 IN15 IN14
DE Vsync Hsync B5 B4 B3 B2
Rxin1 IN13 IN12 IN11 IN10 IN9 IN8 IN7
B1 B0 G5 G4 G3 G2 G1
Rxin0
IN6 IN5 IN4 IN3 IN2 IN1 IN0
G0 R5 R4 R3 R2 R1 R0
13 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.4.3 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input
for the color. The higher the binary input the brighter the color. The table below provides the assignment
of color versus data input.
Data Signal
Color Red Green Blue
R7 R6 … R2 R1 R0 G7 G6 … G2 G1 G0 B7 B6 … B2 B1 B0
Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Red 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
Green 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
Basic Blue 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Colors Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1
Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0
White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Red(0)/Dark 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Red(1) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0
Gray Red(2) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0
Scale : : : : : : : : : : : : : : : : : : :
Of : : : : : : : : : : : : : : : : : : :
Red Red(253) 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
Red(254) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0
Red(255) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
Green(0)/Dark 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Green(1) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0
Gray Green(2) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0
Scale : : : : : : : : : : : : : : : : : : :
Of : : : : : : : : : : : : : : : : : : :
Green Green(253) 0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0
Green(254) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0
Green(255) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
Blue(0)/Dark 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Blue(1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
Gray Blue(2) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
Scale : : : : : : : : : : : : : : : : : : :
Of : : : : : : : : : : : : : : : : : : :
Blue Blue(253) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1
Blue(254) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0
Blue(255) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Note (1) 0: Low Level Voltage, 1: High Level Voltage
14 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.5 DISPLAY TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram.
Signal Item Symbol Min. Typ. Max. Unit Note
DCLK Frequency 1/Tc (67.55) (71.11) (78.22) MHz -
Vertical Total Time TV (813) (823) (833) TH -
Vertical Active Display Period TVD 800 800 800 TH -
Vertical Active Blanking Period TVB TV-TVD (23) TV-TVD TH -
DE
Horizontal Total Time TH (1410) (1440) (1470) Tc -
Horizontal Active Display Period THD 1280 1280 1280 Tc -
Horizontal Active Blanking Period THB TH-THD (160) TH-THD Tc -
Note (1) Because this module is operated by DE only mode, Hsync and Vsync are ignored.
Tv
TVD
DE
TH
DCLK
TC
THD
DE
DATA
15 / 25
www.revo-sys.com
CHIMEI INNOLUX
4.6 POWER ON/OFF SEQUENCE
The power sequence specifications are shown as the following table and diagram.
Value
Symbol Unit Note
Min. Typ. Max.
t1 0.5 - 10 ms
t2 0 - 50 ms
t3 0 - 50 ms
t4 500 - - ms
t5 200 - - ms
t6 200 - - ms
t7 0.5 - 10 ms
tA 0.5 - 10 ms
tB 0 10 ms
tC 10 - - ms
tD 10 - - ms
tE 10 - - ms
tF 10 - - ms
- LED Converter
Enable Signal, 0V
LED_EN
Note (1) Please don’t plug or unplug the interface cable when system is turned on.
Note (2) Please avoid floating state of the interface signal during signal invalid period.
Note (3) It is recommended that the backlight power must be turned on after the power supply for LCD and the
interface signal is valid.
16 / 25
www.revo-sys.com
CHIMEI INNOLUX
5. OPTICAL CHARACTERISTICS
5.1 TEST CONDITIONS
Item Symbol Value Unit
o
Ambient Temperature Ta 25±2 C
Ambient Humidity Ha 50±10 %RH
Supply Voltage VCC 3.3 V
Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS"
LED Light Bar Input Current IL 40 mA
The measurement methods of optical characteristics are shown in Section 5.2. The following items
should be measured under the test conditions described in Section 5.1 and stable environment shown in
Note (5).
θx+ 80 89 -
Horizontal
θx- 80 89 - (1),(5),
Viewing Angle CR≥10 Deg.
θY+ 80 89 - (7)
Vertical
θY- 80 89 -
White Variation of 9 Points (5),(6),
δW 9p θx=0°, θY =0° 70 80 - %
(7)
17 / 25
www.revo-sys.com
CHIMEI INNOLUX
Note (1) Definition of Viewing Angle (θx, θy)
Normal
θx = θy = 0º
θy- θy+
6 o’clock
y- x+ θX+ = 90º
θy- = 90º
90%
Optical
Response
Gray Level 0
10%
0%
Time
TF TR
66.67 ms 66.67 ms
18 / 25
www.revo-sys.com
CHIMEI INNOLUX
Note (4) Definition of Average Luminance of White (LAVE):
Measure the luminance of gray level 63 at 5 points
LAVE = [L (1)+ L (2)+ L (3)+ L (4)+ L (5)] / 5
L (x) is corresponding to the luminance of the point X at Figure in Note (6)
LCD Module
LCD Panel
USB2000 CS-2000T
or equivalent or equivalent
19 / 25
www.revo-sys.com
CHIMEI INNOLUX
Note (6) Definition of White Variation (δW):
Active area is divided into 9 measuring areas (Refer to Fig. 4-4 ).Every measuring point is
placed at the center of each measuring area.
B min
Luminance Uniformity (Yu) =
B max
L-------Active area length W----- Active area width
L
W/6
W/3
Note (7) The listed optical specifications refer to the initial value of manufacture, but the condition of the
specifications after long-term operation will not be warranted.
20 / 25
www.revo-sys.com
CHIMEI INNOLUX
6. RABILITY TEST ITEM
Note (1) Criteria: Normal display image with no obvious non-uniformity and no line defect.
Note (2) Evaluation should be tested after storage at room temperature for more than two hour
Note (3) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
21 / 25
www.revo-sys.com
CHIMEI INNOLUX
7. PACKING
22 / 25
www.revo-sys.com
CHIMEI INNOLUX
8. PRECAUTIONS
8.1 HANDLING PRECAUTIONS
(1) The module should be assembled into the system firmly by using every mounting hole. Be careful
not to twist or bend the module.
(2) While assembling or installing modules, it can only be in the clean area. The dust and oil may cause
electrical short or damage the polarizer.
(3) Use fingerstalls or soft gloves in order to keep display clean during the incoming inspection and
assembly process.
(4) Do not press or scratch the surface harder than a HB pencil lead on the panel because the polarizer
is very soft and easily scratched.
(5) If the surface of the polarizer is dirty, please clean it by some absorbent cotton or soft cloth. Do not
use Ketone type materials (ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid or Methyl chloride. It
might permanently damage the polarizer due to chemical reaction.
(6) Wipe off water droplets or oil immediately. Staining and discoloration may occur if they left on panel
for a long time.
(7) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contacting with hands, legs or clothes, it must be washed away thoroughly with soap.
(8) Protect the module from static electricity, it may cause damage to the C-MOS Gate Array IC.
(9) Do not disassemble the module.
(10) Do not pull or fold the LED wire.
(11) Pins of I/F connector should not be touched directly with bare hands.
23 / 25
www.revo-sys.com
CHIMEI INNOLUX
Appendix. OUTLINE DRAWING
24 / 25
www.revo-sys.com
CHIMEI INNOLUX
N070ICG−LD1 Rev. XX
10
25 / 25