Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

DBETX THM Make

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

DBETX.....

1XT
Proportional pressure relief valve
NG6
Max. Pressure 315 bar
Nominal flow 1 lpm

Features Contents Page No.

Direct operated valves for the limiting system pressure. Features 1

Adjustable by means of the solenoid current, see Symbol 1


performance curve, Technical data and selected valves
electronics. Function and configuration 2

Pressure limitation to a safe level even with electric Ordering details 2


failure (solenoid current l > lmax.)
Technical data 3
For subplate attachment, mounting hole configuration to
ISO4401 Performance curves 4

External trigger electronics with ramps and value Unit dimensions 4


calibration (order separately).

Symbol

For external trigger electronics

P
T

1/5
Function and configuration
Type DBETX proportional pressure relief valve are remote controlled (pilot) valves in conical seat design. They are used to
limit system pressure. The valves are actuated by means of a proportional solenoid. The interior of the solenoid is
connected to port T and is filled with pressure fluid. With these valves, the system pressure that needs to be limited can be
infinitely by the valve amplifier electronics in relation to the solenoid current, at an oil flow < 1L that is as close as possible
to constant.

Basic Principle
To adjust the system pressure, a set point is set in the trigger electronics. Based on this set point, the electronics control
the solenoid coil(1) with regulated PWM (pulse-width-modulated) current. The proportional solenoid converts the current to
a mechanical force, which acts on a main spring(2) by means of the armature plunger. An “additional” spring(5) between
the cone(3) and the seat(4) contributes to stability and a minimal residual pressure. The spring force acting on the same
cone and the pressure in the valve seat balance one another at a constant oil flow (0.7.....1L/min). The “pmax.” pressure
stage is determined by the cone and seating bore configuration.

Pressure limitation for maximum safety


If a fault occurs in the electronics, so that the solenoid current (lmax.) would exceed its specified level in an uncontrolled
manner, the pressure cannot rise above the level determined by the maximum spring force.

Type DBETX.....-1XT/...

5 1

4 3 2

Ordering details

DBETX - 1XT / G24- 8 N Z4 V


*
Further details in
Proportional pressure relief valve the plain text

Series T10~T19 = 1XT V = FKM


No code = NBR
Max. pressure stage
Up to 50bar = 50 Electrical connection
Up to 80bar = 80 K4 = With plug-in connector
Up to 180bar = 180 Z4 = Without plug-in connector
Up to 250bar = 250
Up to 315bar = 315
N = manual auxiliary override

Voltage supply of trigger electronics Solenoid type (current)


24VDC = G24 8 = Solenoid current 0.8 Amax.
25 = Solenoid current 2.5 Amax.

2/5
Technical Data

General
Construction Spool valve
Proportional solenoid without position control,
Actuation
external amplifier
Subplate, mounting hole configuration
Connection type
NG6 (ISO4401-03-02-0-94)
Mounting position Optional
Ambient temperature range ℃ -20...+50
Weight Kg about 2.1
Vibration resistance, test condition Max. 25g, shaken in 3 dimensions(24h)

Hydraulic (measured with HLP 46, νoil = 40 ±5 )


Hydraulic oil to DIN 51524...535,
Pressure fluid
other fluids after prior consultation
recommended mm²/s 20...100
Viscosity range
max. permitted mm²/s 10...800
Pressure fluid temperature range ℃ -20 to +80
Maximum permitted degree of contamination of
pressure fluid purity class to ISO 4406 (c) Class18/16/13

Direction of flow See symbol


Max. set pressure (at Q =1 l/min) bar 50 80 180 250 315
Minimum pressure (at Q = 1 l/min) bar 2 3 4 5 8
Maximum working pressure (at Q = 1l/min) bar Port P:315
Max. Pressure bar Port T:250
Max. Mechanical pressure limitation
bar < 55 < 85 < 186 < 258 < 325
level, e.g. when solenoid current I > Imax.

Static/Dynamic
Hysteresis % ≤4
Response time 100% signal change ms On < 60 / Off < 70
Range of Inversion % ≤3
Electrical
Cyclic duration factor % 100 ED
Degree of protection IP65 to DIN 40050 and IEC 14434/5
Unit plug DIN 43650 / ISO 4400,
Solenoid connection
M16×1.5(2P+PE)
Power 24VDCnom.

3/5
Performance curves (measured with HLP46, t = 40°C ± 5°C)

Pressure in port P as a function of the set point Pmax 100


Nominal flow Qnom = 1L/min
90

P(%)
1). Zero adjustment
2). Sensitivity adjustment 80
(2)
3). Version : UE = 0...10V 70
4). Version : IE = 4...20mA
60
Hysteresis ≤4%
50
40
30
20
10
Pmin→ UE (3)
≈3%P
max 0←(1)→ 2 4 6 8 10 (V)
4 IE (4)

4.4 7.5 10.6 13.8 16.9 20 (mA)

Unit dimensions (Dimensions in mm)

T
32.5
46

31

1). Valve housing


2). Plug-in connector P
3). Identical seal rings for port P
and T(O-ring 9.25×1.78) 13.5 40.5
4). Spacer required to remove the plug-in connector 1 5
3 2 4
5). Proportional solenoid

12

Valve fixing screws


The following valve fixing screws
are recommended:
85

-4GB/T70.1-M5×30-10.9
-Tightening torque MA = 6Nm
46

65
136

40.5
27.8
4×Φ8max 19
10.3 4×M5;10

0.01/100mm T
32.5
26.55

A B
31
0.75

0.8
16.25

P
Required surface finish of the
5.95

valve mounting surface


Installation Dimensions
Mounting surface

4/5
The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.

THM