OrificeMaster Single Chamber Orifice Fitting
OrificeMaster Single Chamber Orifice Fitting
OrificeMaster Single Chamber Orifice Fitting
OrificeMaster ®
Specifications
Issue/Rev. 0.2 (10/06) Bulletin SSOR005
Features
Safety
All OrificeMaster fittings are engineered and manufac-
tured to ensure complete safety to the operator. Before
delivery, each fitting is inspected and pressure tested un-
der strict guidelines to meet all pressure requirements.
Designed to provide maximum safety to the operator
during operation, service and inspection.
The slip-lock design prevents cover plate blow-off in
the event the line has not been depressurized.
Body Styles
R R
O
H
G
Q
S
1/2" NPT Drain D B
A - Bore size to be specified M - Length of studs S - Dowel pin holes not provided on the
by customer N - Diameter of bolt circle 6" fitting and for the 2" through 4"
K - Number of studs O - Clearance to remove ANSI 600 fittings
L - Diameter of studs carrier
Note: Dimensions — inches to the nearest tenth and independently dimensioned from respective engineering drawings.
I I
SA216 WCC
1/2" NPT Tap Holes
(Both Sides)
E
Note: Dimensions — inches to the nearest tenth and independently dimensioned from respective engineering drawings.
Note: Dimensions — inches to the nearest tenth and independent- A - Bore size to be specified by customer
ly dimensioned from respective engineering drawings. J - Number of bolts or studs
K - Size of bolts or studs
L - Length of bolts
Notes:
1 Flow indicated is recommended, although direction of flow is optional.
2 Plate thickness: 1/8" for line sizes 6 ", 1/4" for line sizes 8" through 14", 3/8" for line sizes 16" through 20 ", 1/2" for 24" line size.
3 Pressure taps 1/2" standard pipe threads.
4 Consult factory for weld neck fittings larger than 24".
5 Maximum Allowable Working Pressure.
Note: Dimensions — inches to the nearest tenth and independent- A - Bore size to be specified by purchaser
ly dimensioned from respective engineering drawings. J - Number of bolts or studs
K - Size of bolts or studs
L - Length of bolts
CF - Consult Factory
Notes:
1 Flow indicated is recommended, although direction of flow is optional.
2 Plate thickness: 1/8" for line sizes 6 ", 1/4" for line sizes 8" through 14", 3/8" for line sizes 16" through 20 ", 1/2" for 24" line size.
3 Pressure taps 1/2 inch standard pipe threads.
4 Consult factory for weld neck fittings larger than 24".
5 Maximum Allowable Working Pressure.
6 Consult factory for orifice fittings higher than 1500 ANSI Class.
The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently
in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.
Headquarters:
500 North Sam Houston Parkway West, Suite 100 Houston, TX 77067 USA, Phone: +1 (281) 260-2190, Fax: +1 (281) 260-2191
Gas Measurement Products: Liquid Measurement Products:
Houston, TX USA +1 (281) 260-2190 Erie, PA USA +1 (814) 898-5000 Beijing, China +86 (10) 6500-2251
Thetford, England +44 (1842) 82-2900 Los Angeles, CA USA +1 (310) 328-1236 Singapore +65 6861-3011
Kongsberg, Norway +47 (32) 286-700 Slough, England +44 (1753) 57-1515 Chennai, India +91 (44) 450-4400
Buenos Aires, Argentina +54 (11) 4312-4736 Ellerbek, Germany +49 (4101) 304-0
Integrated Measurement Systems: Barcelona, Spain +34 (93) 201-0989
Corpus Christi, TX USA +1 (361) 289-3400 Moscow, Russia +7 (495) 564-8705
Kongsberg, Norway +47 (32) 286-700 Melbourne, Australia +61(3) 9807-2818
San Juan, Puerto Rico +1809 (787) 274-3760
United Arab Emirates, Dubai +971 (4) 331-3646
Visit our website at www.fmctechnologies.com/measurementsolutions
Printed in U.S.A. © 4/02 FMC Technologies Measurement Solutions, Inc. All rights reserved. SSOR005 Issue/Rev. 0.2 (10/06)