Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Presentación DL8000 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

DL8000 Preset

Remote Automation Solutions


New Preset Platform
• What is a preset?
– A flow computer with additional layers of control
– Packaged for hazardous areas
– Rugged interface according with load rack conditions
– Controller, Keyboard, Display for batching activity

+ +
Sequentia l
Managem ent
System

=
GALLONS
Volume
Corrected to 60F

Remote Automation Solutions


Remote Automation Solutions
Preset Market
Refining
and Electronic Preset
Chemical Blending Oxygenates

Processing

STRAINER
OVAL Security Access
CHECK SOLENOID

TEST

Additive Injection Panel

Additive Injection Flow Control Valve


Air Elimination & Flow Conditioning Flowmeter

Remote Automation Solutions


Current Preset Philosophy
• Single arm, dedicated presets, add sequential or ratio
blending with additives.
• Lowest risk with residual effect of equipment failure
minimized
INPUTS OUTPUTS
Permissives Pulse Per Unit Volume
Additive Selection Trip
Recipe Selection Recipe Selections
TAS Auto/Manual Component Combination
Alarm Reset Alarms
Terminal Automation Valve Control
Temperature Probe Ticket Printing
Pressure Sensor Meter Proving
Densitometer Terminal Automation

A
A Additives D P T

D Densitometer From
Product M
P Pressure Sensor Pump
Strainer Block Valve Meter: Control Valve
PD
T Temperature probe
Coriolis
Turbine

Remote Automation Solutions


Key Design Considerations
• Customer up-time is critical. Peace of mind is vital.
High reliability is important.
• Flexibility of design
– Single arm (Multiple Arm in Future)
– Up to 4 products, Up to 6 Additives
– Ability to handle up to 30 recipes
– Expand to different communications (Ethernet, Wireless,
Serial)
– Standard programming language architecture (IEC)

• Same platform used for pipeline metering station

Remote Automation Solutions


Single Arm, Single Product
Single Product Top Load -
Arm Position
or
Single Product Stre am I/O Count
Single Product Bottom Load - 1- APM
One additive 2-PI (Turbine Dual Pulse)
Additive Pumps 1-PI (Additives Injector)
(ACO) 1- Densitometer Input
1- AC-IO
1- AC Permissive Power
P-1 1 - Product Pump
1 - Product Select Valve
1 - Injector Pump ,1 - Injector Valve
or 2- Arm Position
Flowmeter
2- Control Valve
(1-PI)
1 - RTD
1 - RS485 Modbus

Additive Select
Valves V-1
(ACO)

Single Product Stre am Arm


Position
(2-ACI

T T

Temperature Density
Product Select Valve Strainer Flowmeter Valve
(1-RTD) (or Pressure)
Pump (1ACO) (2-PI) (2-ACO)
(1-ACO)

Remote Automation Solutions


Single Arm, Two products,
Two Additives, Sequential Blending
Two Products Top Load -
Arm Position E-13 E-14
Additives
or V-13 V-11

Three Product Streams Total Configuration


Two Products Bottom Load - AC_IO - 12 (2 Modules)
2 - Additive Control
One additive 4 - Product Control
2 - Main Valve Control
2 Arm Position or Second Additive
APM - 4 (1 Modules)
1 - Dual Pulses Main Meter
1 - Injector Pulse
1 - Desitomiter
RTD (1 Modules)
I - Main,
RS485 Modbus (2 Modules)
1 - Remote Monitoring(Modbus)
Display connected to CPU

Product Streams
Arm Position Indication
2 AC-IO

Valve (1-AC_IO)
T T

Pump
(1-AC_IO) Temperature Densitometer
Strainer Flowmeter Valve
(1-RTD) (or pressure)
(2-PI) (2-AC_IO)
(2-RS 485 Modbus)
Valve (1AC_IO)
Pump
(1-AC_IO)

Remote Automation Solutions


Single Arm, Three products,
Three additives, Sequential Blending
Three Stream Sequential Blend
E-12 E-13 E-14 with 3 Additives
V-15 V-13 V-11
Three Product Streams Total Configuration
AC_IO - 18 (3 Modules)
Additives
6 - Additive Control
6 - Product Control
2 - Main Valve Control
2 Arm Position
2 - Permissives monitors
APM - 6 (2 Modules)
2 - Dual Pulses Main Meter
3 - Injector Pulses
1 - Desitomiter
4 - RTD (1 Modules)
Product Streams
I - Main,
RS485 Modbus (2 Modules)
1 - Printer
1 - Remote Monitoring(Modbus)
Valve (1-AC_IO)
Display connected to CPU
Pump
(1-AC_IO)

Valve (1-AC_IO)
T T

Pump
(1-AC_IO) Temperature Densitometer
Strainer Flowmeter Valve
(1-RTD) (or pressure)
(2-PI) (2-AC_IO)
(2-RS 485 Modbus)
Valve (1AC_IO)
Pump
(1-AC_IO)

Remote Automation Solutions


Single Arm, Three Products
Three additives, Ratio Blending
Three Stream Ratio Blending
E-12 E-13 E-14 with 3 Additives
V-15 V-13 V-11
Three Product Streams Total Configuration
AC_IO - 18 (3 Modules)
Additives
6 - Additive Control
6 - Product Control
2 - Main Valve Control
2 - Permissives
2 - Arm Position
APM - 8 (3 Modules)
6 - Dual Pulses Main Meter
3 - Injector Pulses
3 - Desitomiter
RTD - 4 (2 Modules)
Product Streams
I - Main,
3 - Product
T
RS485 Modbus (1Modules)
1 - Remote Monitoring(Modbus)
Valve (1-AC_IO) Flowmeter Temperature Display connected to CPU
(2-PI) (1-RTD)
Pump
(1-AC_IO)

Valve (1-AC_IO) Flowmeter Temperature


(2-PI) (1-RTD) T

Pump
(1-AC_IO) Temperature
Strainer Valve
(1-RTD)
(2-AC_IO)
T

Valve (1AC_IO) Flowmeter Temperature


(2-PI) (1-RTD)
Pump
(1-AC_IO)

Remote Automation Solutions


Emerson Adopts a New Platform
• The 800 platform is proven in many duties:
– Liquid flow computer; upstream, production and downstream
– Gas flow computer; natural and pure gases
– PLC; process, pipeline, utilities, etc.
– RTU
– The Preset is an application extension of the flow computer
• The 800 platform is a low risk option
– Is field proven
– Thousands of units sold

Remote Automation Solutions


The 800 Platform
• Platform and hardware common with existing technology
• The 800 platform may be used plant-wide for many
applications
• Network capability (Ethernet) makes plant-wide LAN
based systems a possibility
• Upgrading without EPROM changes
• Expand the applications with standard Development Suite
software

Remote Automation Solutions


Outstanding Functionality
High performance CPU IEC61131-3
and real-time operating compliant
system programming

Sophisticated
Distributed
valve control
architecture

Flexible logic and


Fast, accurate API sequencing
flow calculations control

Broad
communications
Fill-in-the-blanks capability
configuration

Remote Automation Solutions


DL8000 Capabilities
• Configuration is Variable, full configuration is:
– Meters – Up to 4
– Pulse Inputs – Up to 12 single, 6 dual, 2 Density
– AC Input/Output up to 18 points
– Up to 6 Additives
– RTD Up to 4 inputs
– Com Ports (RS232, RS485, Ethernet) up to 2 (plus 3
of CPU card)
– By reducing one capacity we can increase or add
others – I/O is flexible

Remote Automation Solutions


Features
• Reliable and robust design
– Extensive opto-isolation
• Packaging options
– Explosion Proof DL6000 Enclosure
• Communications flexibility
– RS232, RS-485 & Ethernet
• Flexible, user friendly configuration
– Intuitive Windows based configuration software
• Extensive calculation library
• Scalable
Remote Automation Solutions
Flexible Installation Options

Class 1 Division 1 Class 1 Division 2


Explosion Proof Future NEMA 4X

Remote Automation Solutions


Standard Offering – Slot Allocations

CPU PSU
3 2 1
RTD RS-232 RS-485
6 5 4
RTD APM APM
9 8 7
AC I/O AC I/O AC I/O

Hot swappable modules


Modules self identifying

Remote Automation Solutions


Standard Modules Available
• Pulse input (Two channel - Single Pulses or Advanced
Pulse Module) or Pulse Output
• Analog input and output
• RTD input
• Discrete input and output (AC & DC)
• Communications (RS-232, RS-485, Modem, Ethernet)
• Relay output
• AC-I/O
• HART
• PSU (12 VDC, 24VDC, 120/240 VAC)
Remote Automation Solutions
Highly Configurable
• ROCLINK Software
– Fill in the Blank
Configuration
– Simple, easy to use
– Windows based
– Printing of Calibration
Reports

Remote Automation Solutions


Highly Configurable
• DS 800 Development Suite
– Functional Block Diagram Programming
– Ladder Diagram Programming
– Structured Text Programming

• Function Sequence Tables (FST)


• ROConnect for OPC driver and Delta-V Integration

Remote Automation Solutions


Delta V Terminal System

Remote Automation Solutions


Secure Communications
• With the Ethernet capability
of the 800 platform, it is
possible to effectively extend
the company’s local area
network (LAN) to the field.
• Ethernet is faster and less
expensive than conventional
communications methods.
• RS-485 & RS-232 options
are included to meet varying
requirements

Remote Automation Solutions


DL8000 Highlights
• Modular Construction
– Low Density IO
– Failed modules have less impact, easier to replace
– Hot swappable
• Isolated IO, Rugged environmental design
• Latest API standards
– Latest Tables
– Double Precision Floating Point Math
• Expandable
– Expanded IO can reduce total cost per measurement

Remote Automation Solutions


Future Considerations
• Multiple arm control
• Class 1 Division II packaging to permit
expansion using ROC827 Platform, Safe Area
installation
• PetroCount protocol (Brooks)

Remote Automation Solutions


Emerson Process Management
• Terminal Management Solutions – PlantWeb, AMS
• Daniel – Liquid Turbine meters, Liquid Ultrasonic Meters,
Valves, Compact Prover
• Emerson Tank Gauging Solutions – Saab-Rosemount
tank level measuring systems
• Micro Motion – Coriolis meter, Solartron Densitometers
• Rosemount - Pressure transmitters, Temperature
transmitters
• Remote Automation Solutions – Presets, Flow
computers, RTU’s

Remote Automation Solutions


SupportNet

Remote Automation Solutions


Summary
• Supports global standards – ISO, API etc.
• Network capability with Ethernet and standard
Modbus
• The Next Generation Preset utilizes the 827 platform
– Flexible packaging for hazardous and safe area
options
– Future Scalable using the ROC827 Concept
– Reliable design and hardware configuration
– Configurable using ROCLINK and DS800
Development Suite

Remote Automation Solutions

You might also like