Parker Rotary Knife
Parker Rotary Knife
Parker Rotary Knife
Overview
The custom machine (Figure 1) consists of a web feed rotary knife
controlled by an MTS Automation control system. The web is transported
by pull rollers driven by a variable speed motor. The pull rollers act as the
reference axis for the control system. The rotary knife accelerates and
decelerates as the reference accelerates and decelerates.
The control system consists of a VRP 500 digital servo controller with
custom firmware to provide for the control of a single axis.
The servo axis operates the rotary knife in ratio mode to the web. The
knife makes a cut at relative speed (overspeed) to the web. After the knife
has cleared the web it rotates around in time for the next cut. After an
operator-selected number of cuts (COUNT) have been made Output 1 will
come on and stay on for 250 ms. During operation the operator can make
incremental changes to the part length (trim) and COUNT.
1
Hardware Description
The control unit consists of a VRP 500 with custom firmware for
calculation of profiles and a COUNT output. Programmable limit switch 1
is designated as the COUNT output.
Command
Reference
Enable
E
M
Master
Encoder Rotary
Knife
E
Web
Pull
Rollers
Elevator
Figure 1
2
Description of Operation
Profile Calculation
The machine designer enters the following machine parameters into the
VRP 500, while the RUN line is off, through the custom SETUP
[MACHINE] screen:
The operator enters the following product parameters into the VRP 500,
while the RUN line is off, through the custom PRODUCT mode:
After all the parameters (product and machine) have been entered, the
operator presses the CALC function key; profile 0 is calculated, the home
position is calculated, and the COUNT register is reset to zero. The CALC
function is active from both the PRODUCT screen and the SETUP
[MACHINE] screen. If there is no solution for the parameters that have
been entered, an error message is displayed; DATA ERROR n. Appendix
A describes the error messages.
3
Motion Profiles
The motion profile has the following profile segments: a cutting segment,
a non-cutting constant velocity (relative to the reference) segment, and
the transitional segments between the cutting and non-cutting segments.
The knife always travels one cycle per part. (This means that the number
of knives per revolution is identical to the number of cycles per revolution.)
The reference travels the part length ± trim units per part. The cutting
segment is defined by the product parameter, overspeed (cutting speed),
machine parameter, and percent of knife cycle at overspeed. The non-
cutting constant velocity portion is the segment that is altered by the trim
adjustment. The transitional segments are constant acceleration
segments (relative to the reference). The acceleration used to make these
transitions is the maximum acceleration of the machine when the web is
running at maximum web speed. See Figure 2 below.
Cutting Period
Time
1 Rev
Reference Position
Figure 2
4
Home Position
The home position of the follower is automatically calculated and
displayed in the SETUP [FOLLOWER] menu. This position is defined as
the point in the follower cycle where the knife is in the cut position. Once
calculated, this parameter should not be changed (if it is changed, the cut
will not be positioned correctly in the cycle).
The knife offset position must be entered to compensate for the distance
between the knife cut position and the follower home sensor position. If
the home sensor is before the cut, this offset should be a negative value.
If the home sensor is after the cut, this offset should be a positive value.
Once set correctly, any changes in product or profile will automatically be
calculated to ensure that the knife cuts at the correct point in the profile.
On Power-Up
The accumulated COUNT register is set to zero. The new custom mode
PRODUCT will be the first screen visible on power-up. All other operations
of the VRP 500 at power-up are the same as the standard VRP 100.
If the knife axis is moving, it decelerates to a stop using the rate defined
by ALIGN ACC. The accumulated COUNT register is not reset. All other
operations of the VRP 500 at power-up are the same as the standard
VRP 100.
The accumulated COUNT register is reset to zero. All other actions are
the same as the standard VRP 100.
Select Profile 1 to 3
5
Operator Interface
Parameter Entry
Machine and product parameters are entered into the VRP 500 via the
numeric keypad. For example, to enter machine setup parameters, press
the mode key until the SETUP mode is on the screen. Then press the
arrow keys until the SETUP [MACHINE] screen is present and press the
EDIT key. Press the function keys NEXT and PREV until the desired
machine parameter is displayed. Key in a new value and press ENTER.
This saves the new value.
After these values are entered, they are saved in non-volatile-memory and
remain even if power is removed. If there is a version or parameter
checksum fault, the custom parameters will be reset to zero, except for:
6
Machine Parameters
MACHINE
REF ACEL INCR
(xxx)msec
CALC PREV NEXT
7
Product Parameters
PRODUCT PRODUCT
PART LENGTH CYCLE RATE
(xxxx.xx)in (xxx.xxx)prt/min
SAVE CALC NEXT SAVE CALC NEXT
PRODUCT PRODUCT
OVERSPEED COUNT
(xxx.xxx)% [xxxxx]
SAVE CALC NEXT SAVE CALC NEXT
The product parameters are entered into the custom mode called
PRODUCT. These parameters are overspeed, part length, cycle rate, and
COUNT. During operation, the part length can be incrementally adjusted
using the arrow keys on the controller keypad. The size of the increment
is defined in the SETUP [MACHINE] screen. If the length is incremented
to the maximum trim limit, further attempts to increment the trim will be
ignored.
Changes in length beyond the trim limit must be made by stopping the
machine and entering a new product length through the PRODUCT
screen. The profile must then be calculated using the CALC function
before the change has an effect on the product length. This is the same
procedure that must be followed to make changes to the overspeed and
cycle rate limit.
If the operator runs the machine at a cycle rate higher than the value that
was entered into the PRODUCT mode CYCLE RATE, the controller will
attempt to accelerate the knife motor at rate higher than the maximum
knife acceleration that was entered as a machine parameter. The
maximum velocity of the knife may also be exceeded in this case. MTS
Automation cannot guarantee what will result in this case. The effect will
depend on what happens to the specific machine and motor when the
motor is commanded to accelerate faster than the machine/motor
specification. Possible results include: the parts will not be of the proper
length, the knife motor will overheat, or the knife motor will shut down. If
the knife is actually capable of the resulting acceleration and velocity,
there will be no effect.
The COUNT can be changed while running. The new value will take effect
before 2 complete cycles. A cycle is defined as making COUNT cuts. The
maximum count is 32,767.
8
Documentation
The following sources are available:
Miscellaneous
Unless otherwise specified, the operation/performance of the custom VRP
500 controller is limited to the performance of the standard VRP 100.
How to Order
Part Number 462576-05
Includes VRP Controller, custom firmware, VRP 500 label, and User’s
Manual.
9
APPENDIX A. DATA ERROR
MESSAGES
DATA ERROR 1
1. Maximum trim size is larger than the minimum part length. Increase
the minimum part length or decrease the maximum trim adjustment.
2. Maximum trim size is less than the trim step size. Either increase the
maximum trim size or decrease the trim step size.
DATA ERROR 2
10
DATA ERROR 3
DATA ERROR 4
The requested setup would require the velocity during the cut portion of
the cycle to exceed the maximum velocity of the knife.
DATA ERROR 5
1. Decrease the speed of the web. The speed of the web is limited to; the
maximum speed of the web, or the product of the cycle rate and
product length, whichever is lower.*
2. Increase the percent overspeed.*
3. Increase the length of the part.*
4. Decrease the maximum trim length.
5. Decrease the percent of cycle at matched speed.
11
DATA ERROR 6
1. Decrease the speed of the web. The speed of the web is limited to; the
maximum speed of the web, or the product of the cycle rate and
product length, whichever is lower.*
2. Decrease the percent overspeed.*
3. Increase the length of the part.*
4. Decrease the maximum trim length.
5. Decrease the percent of cycle at matched speed.
DATA ERROR 7
Velocity of knife during the non-cutting portion of the cycle is greater than
the maximum knife velocity.
DATA ERROR 8
12