DDR 30 Spec PDF
DDR 30 Spec PDF
DDR 30 Spec PDF
■ Feature ■ Applications
Width only 35mm (2SU) Industrial control system
4:1 ultra wide input range Semi-conductor fabrication equipment
-40~+85℃ wide working temperature Factory automation
No minimum load required Electro-mechanical
DC output adjustable (±10%) Wireless network
Cooling by free air convection Telecom or datacom system
Can be installed on DIN rail TS-35/7.5 or 15
Protections: Short circuit / Overload / Over voltage /
Input reverse polarity /
Input under voltage protection
4KVdc I/O isolation(Reinforced isolation)
3 years warranty
■ Description
DDR-30 series is a 30W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation,
ultra slim width (35mm), 4:1 ultra wide input voltage, -40~+85℃ wide operating temperature, 4KVdc I/O isolation,
adjustable output voltage (± 10%) and full protective functions...etc.
This series has two input options: 9~36V /18~75V and various output options: 5V / 12V / 15V / 24V and can
be used for industrial control, security control, communication system and other fields. Suitable applications
are DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.
■ Model Encoding
DDR - 30 G - 24
Output voltage(5/12/15/24Vdc)
Input voltage (G: 9~36Vdc, L:18~75Vdc)
Rated wattage
Series name
File Name:DDR-30-SPEC 2018-02-02
30W DIN Rail Type DC-DC Converter DDR-30 series
SPECIFICATION
MODEL DDR-30G-5 DDR-30G-12 DDR-30G-15 DDR-30G-24 DDR-30L-5 DDR-30L-12 DDR-30L-15 DDR-30L-24
DC VOLTAGE 5V 12V 15V 24V 5V 12V 15V 24V
RATED CURRENT 6A 2.5A 2A 1.25A 6A 2.5A 2A 1.25A
CURRENT RANGE 0 ~ 6A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.25A 0 ~ 6A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.25A
RATED POWER 30W 30W 30W 30W 30W 30W 30W 30W
OUTPUT RIPPLE & NOISE (max.) Note.2 60mVp-p 75mVp-p 75mVp-p 100mVp-p 60mVp-p 75mVp-p 75mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 9 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 28V 4.5 ~ 5.5V 9 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 28V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.5% ±0.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 120ms, 85ms at full load
HOLD UP TIME (Typ.) G-type: 7ms@24Vdc input L-type: 18ms@48Vdc input
EXTERNAL CAPACITANCE
LOAD (Max.) 3300μF 2200μF 1500μF 1000μF 3300μF 2200μF 1500μF 1000μF
VOLTAGE RANGE Note.4 9 ~ 36Vdc 18 ~ 75Vdc
EFFICIENCY (Typ.) 85% 86% 87% 89% 86% 89% 90% 91%
INPUT
DC CURRENT (Typ.) 1.5A /24Vdc 0.8A /48Vdc
INRUSH CURRENT (Typ.) 15A /24Vdc 15A /48Vdc
110 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION 5.75 ~ 7V 13.8 ~ 16.2V 17.25 ~ 20.25V 28.8 ~ 34V 5.75 ~ 7V 13.8 ~ 16.2V 17.25 ~ 20.25V 28.8 ~ 34V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
REVERSE POLARITY By internal MOSFET, no damage, recovers automatically after fault condition removed
24Vin (G-type):Power ON≥9V , OFF≤8.5V
UNDER VOLTAGE LOCKOUT
48Vin (L-type):Power ON≥18V , OFF≤17V
WORKING TEMP. -40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY 5 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE 2000 meters
SAFETY STANDARDS IEC 62368-1 (LVD) approved, Design refer to UL508
WITHSTAND VOLTAGE I/P-O/P:4KVdc
ISOLATION RESISTANCE I/P-O/P>100M Ohms / 500Vdc / 25℃/ 70% RH
Parameter Standard Test Level / Note
Conducted EN55032 Class B
EMC EMISSION Radiated EN55032 Class B
Voltage Flicker EN61000-3-3 -----
SAFETY &
EMC EN55024 , EN61000-6-2(EN50082-2)
(Note 5) Parameter Standard Test Level / Note
ESD EN61000-4-2 Level 3, 8KV air ; Level 3, 6KV contact; criteria A
Radiated EN61000-4-3 Level 3, 10V/m ; criteria A
EFT / Burst EN61000-4-4 Level 3, 2KV ; criteria A
EMC IMMUNITY
Surge EN61000-4-5 Level 3, 1KV/Line-Line ; criteria A
Conducted EN61000-4-6 Level 3, 10V ; criteria A
Magnetic Field EN61000-4-8 Level 4, 30A/m ; criteria A
MTBF 483.3K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 35*90*54.5mm (W*H*D)
PACKING 0.12Kg;96pcs/12.5Kg/1.04CUFT
1. All parameters NOT specially mentioned are measured at normal input (G:24Vdc, L:48Vdc), rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
NOTE 5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with
the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than
2000m(6500ft).
Block Diagram
fosc : 100KHz
DETECTION
PWM CIRCUIT
O.L.P. CONTROL
O.V.P.
Derating Curve
100
LOAD (%)
50
40
100
90
85
80 DDR-30L-5/12/15/24
DDR-30G-5/12/15/24
LOAD (%)
70
60
50
40
9 12 18 24 30 36
18 24 36 48 60 75
INPUT VOLTAGE
Mechanical Specification
( Unit: mm , tolerance ± 0.5mm)
58.4
35 54.5
2 1
Power LED
63.65
45.15
90
4 3
35
Installation Manual
Please refer to : http://www.meanwell.com/manual.html