Description
The SIPROTEC 7UT85 transformer differential protection
device has been designed specifically for the protection of
two-winding transformers (2 sides). It is the main protec-
tion for the transformer and contains many other protec-
tion and monitoring functions. The additional protection
functions can also be used as backup protection for pro-
tected downstream objects (such as cables or lines). In this
regard you are also supported by the modular expandabil-
ity of the hardware. With its modular structure, flexibility
and the powerful DIGSI 5 engineering tool, SIPROTEC
7UT85 offers future-oriented system solutions with high
investment security and low operating costs.
SIPROTEC 7UT85
Main function 1 differential protection function (standard or
auto transformer) with additional stabiliza-
tion; up to 2 restricted ground-fault protection • Transformer differential protection for phase-angle
functions regulating transformers of the single core type and
Usable measur- 5 x 3-phase current measuring points, special transformers
ing 3 x 1-phase current measuring points,
• Applicable from average up to extra-high voltage
points 3 x 3-phase voltage measuring points;
expandable to 3 sides • Protection of standard power transformers, auto
Inputs and 2 predefined standard variants with transformers and motors
outputs 8 current transformers, 7 to 19 binary • Typical properties of a transformer differential protec-
inputs, 7 to 23 binary outputs tion such as flexible adaptation to the transformer
Hardware Flexibly adjustable and expandable vector group, control of inrush and overexcitation
flexibility I/O quantity structure within the scope processes, safe behavior in the case of current-
of the SIPROTEC 5 modular system transformer saturation with different degrees of
Housing width 1/3 × 19 inch to 2/1 × 19 inch saturation
• Adaptive adaptation of the operate curve to the
Functions transformer tap position
DIGSI 5 permits all functions to be configured and com-
bined as required. • Increased sensitivity with near-neutral-point ground
faults through a separate restricted ground-fault
• Transformer differential protection for two-winding protection
transformers with versatile, additional protection
functions; expandable to 3 windings • Additional current and voltage inputs can be supple-
ments for standard protection functions, such as
overcurrent, voltage frequency and others
Modular and flexible