Automatic Circuit Reclosers/
Sectionalisers
1 2
4
3
Current and voltage transformers molded into the I-side terminal allow
easy monitoring for your overhead voltage network, and with optional
voltage measurement on the X-side terminal, you have automation
capabilities for your electricity distribution network or substation.
Reduced purchasing, installation and operating costs, with intelligent solid-dielectric switchgear.
Offering solid-dielectric insulation in a cost effective solution, E-Series Automatic Circuit Reclosers provides the updated
technology in vacuum interrupters, encased in an hydrophobic epoxy resin moulding.
The switching mechanism and switchgear microelectronics are enclosed in a stainless steel tank.
Current transformers molded into the I-side terminal allow easy monitoring for your overhead voltage network, and voltage
transformers molded into the I-side terminal and X-side terminal for voltage measurement. You have automation capabilities
for your electricity distribution network or substation.
A mechanical lockout and visible On/Off indicator provides instant visual indication of the switchgear state.
This solution offers protection technology and low maintenance Automatic Circuit Recloser.
Available in 15kV, 27kv and 38kV models, the E-series has a rated continuous current of 630A/800A* for 15/27kV and 800A/1250A*
for 38kV with 150kv BIL for 15/27kV and 170kV BIL for 38kV.
4 schneider-electric.com
3 Single Phase Solutions with W-Series reclosers upto 24 kV
Automated protection for single phase or SWER (Single Wire Earth Return) applications.
Using the updated technology in solid-dielectric insulation and vacuum arc interruption, the W-Series Single Phase ACR
provides automation and remote control on one phase.
Housed in a 316 stainless steel tank, and including features such as manual trip, visible external On/Off indicators, the
W-Series is suitable for any single phase requirement.
RL-Series Load Break Switches/Sectionalisers provide a simple low cost solution for your electricity distribution network.
Contained in a hard wearing, SF6 gas-filled, 316 stainless steel enclosure is the updated arc quenching technology, short
arcing times (within half a cycle), plus tulip-type contacts with arc-resistant (Cu-W) material providing a long switching life and
extended short circuit making capability.
This innovative design provides a quick manual tripping using the hookstick and the closed switch arm, irrespective of fast or
slow movement of the switch arm.
The RL-Series LBS is available in bare terminal or fully insulated bushing arrangement, and 15 kV,
27 kV or 38 kV models (rated continuous current - 630 A).
Features
Increased revenue with lower operating costs makes this intelligent switchgear the appropriate
choice.
From manual sectionalising and single phase protection, up to large scale DSA/SCADA controlled electricity distribution
networks and substations, you have the solution for your every overhead medium-voltage need.
6 schneider-electric.com
Switchgear Comparison Table
U-SERIES E-SERIES RL-SERIES W-SERIES
15 kV 27 kV 15 kV/27 kV 38 kV 15 kV 27 kV 38 kV 24 kV
12.5 kA 12.5 kA 12.5 kA 16 kA 12.5/16 kA 12.5/16 kA 12.5/16 kA 6 kA
RATINGS
Rated Maximum Voltage 15.5 kV 27 kV 15/27 kV 38 kV 15.5 kV 27 kV 38 kV 24 kV
Rated Nominal Voltage 21 kV
(phase to ground)
Rated Continuous 630 A 630 A 630 A 800 A 630 A 630 A 630 A 400 A
Current
Fault Make Capacity 12.5 kA 12.5 kA 12.5 kA 16 kA 12.5/16 kA 12.5/16 kA 12.5/16 kA 6 kA
(RMS)
Fault Make Capacity 31.5 kA 31.5 kA 32.5 kA 41.6 kA 31.5/40 kA 31.5/40 kA 31.5/40 kA 15 kA
(Peak)
Power Operating Time
(Close/Open) 0.1/0.05 s 0.1/0.05 s 0.1/0.05 s 0.1/0.05 s <2s <2s <2s 0.1/0.05 s
Mechanical Operations 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000
Rated full load 10,000 10,000 10,000 10,000 600 600 400 10,000
operations
Short time current 12.5 kA 12.5 kA 12.5 kA 16 kA 12.5/16 kA 12.5/16 kA 12.5/16 kA 6 kA
BREAKING CAPACITY
Mainly Active (0.7pf) 630 A 630 A 630 A 800 A 630 A 630 A 630 A 400 A
Fault break capacity 12.5 kA 12.5 kA 12.5 kA 16 kA 6 kA
Cable charging 25 A 25 A 25 A 40 A 25 A 25 A 25 A 25 A
Line charging 5A 5A 5A 5A 10 A 10 A 10 A 5A
Capacitor bank
LIGHTNING IMPULSE WITHSTAND LEVEL
Phase to Phase 125 kV 150 kV 170 kV
Phase to Earth 110 kV 125 kV 150 kV 170 kV 125 kV 150 kV 170 kV 125 kV
Across Interrupter 110 kV 125 kV 150 kV 170 kV 145 kV 170 kV 200 kV 125 kV
POWER FREQUENCY WITHSTAND VOLTAGE
Phase to Earth 50 kV 60 kV 60 kV 70 kV 40 kV 60 kV 70 kV 60 kV
Across Interrupter 50 kV 60 kV 60 kV 70 kV 50 kV 60 kV 80 kV 60 kV
SERVICE CONDITIONS
Ambient Temperaturea -40 to 50 -40 to 50 -40 to 50 -40 to 50 -30 to 50 -30 to 50 -30 to 50 -30 to 50
(ºC)
Ambient Temperature a
-40 to 122 -40 to 122 -40 to 122 -40 to 122 -22 to 122 -22 to 122 -22 to 122 -22 to 122
(ºF)
Radiation (Max) 1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m 2
1.1 kW/m2
Humidity 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100%
Altitude meters (Max)b 3000 3000 3000 3000 3000 3000 3000 3000
Altitude feet (Max)b 9840 9840 9840 9840 9840 9840 9840 9840
NET WEIGHTS
Circuit breaker with pole 146/322 146/322 170/375 205/452 128/282 128/282 128/282 75/165
mount bracket (kg/lbs)
Control cubicle with 41/90 41/90 41/90 41/90 41/90 41/90 41/90 41/90
control cable (kg/lbs)
Gross weight of crate 263/580 263/580 275/606 350/771 285/628 285/628 285/628 196/432
(kg/lbs)
External VT (kg/lbs) (N 60/132 60/132 60/132 60/132 60/132 60/132 60/132 60/132
series Only)
CRATE DIMENSIONS
Width (mm/in) 960/37.8 960/37.8 1140/44.8 1140/44.8 1200/47.2 1200/47.2 1200/47.2 1150/45.3
Depth (mm/in) 1020/40.2 1020/40.2 1080/42.5 1080/42.5 1150/45.3 1150/45.3 1150/45.3 1150/45.3
Height (mm/in) 1160/45.7 1160/45.7 1140/44.8 1220/48 755/29.7 755/29.7 755/29.7 570/22.4
IEC and IEEE STANDARDS
IEC62271-
Applicable Standards IEC62271-111 and IEEE C37.60 IEC62271-103 111 and IEEE
C37.60
a. Option when cubicle battery heater is fitted (-10ºC to 50ºC {-14ºF to 122ºF} without heater)
b. For altitudes above 1000 m (3280 feet), derate in accordance with IEEE C37.60 for reclosers (IEEE C37.63 for LBS)