2 INTRODUCTION
The advancement in design and compactness of electronics
generates enormous heat during its operation.
Exp. study on closed loop two kyun • Appropriate size of condenser and adequate amount of
phase thermosyphon devices et al charging liquid – crucial factors – performance of
for cooling MCMs 2010 thermosyphon
Heat Transfer Engg (T&F) • Selection of component sizes – important constraints – for
natural convective heat transfer
Two phase closed loop Chang • Condenser and evaporator thermal resistance decreases with
thermosyphon for electronic et al increasing of heat input
cooling 2010 • Thermal resistance decreases and heat transfer co-efficient
Exp. Heat Transfer (T&F) increases with increasing of heat power input
Exp. Investigation of PCM as Mahdieh • Liquid cooling by pump is efficient - chance of leakage -
coolant of electronic chipsets et al unstable operation of electronic devices
Applied Thermal Engg 2016 • Closed loop thermosyphon is best way – without use of
(Elsevier) electrical power
5 LITERATURE REVIEW
TITLE OF THE PAPER AUTHOR OBSERVATIONS MADE
NAME
Exp. Investigation & Naik • The exp. results indicates acetone - better working fluid - lower
performance evaluation of a et al thermal resistance and higher heat transfer coefficient
closed loop pulsating heat 2012 • At high heat input, superheat will be more which leads to nucleate
pipe. Journal of Applied boiling consequently thermal resistance is low
Fluid Mechanics
A comparative study of the Han • The increase in heat input reduces the viscosity of working fluid.
behavior of working fluids and et al • The specific heat and latent heat of evaporation increases with heat
their properties on the 2014 input which caused for the reduction in thermal resistance.
performance of pulsating heat
pipes IJTS (Elsevier)
Application of TCE-PCM Sahoo • The TCE filled metallic PCM is desirable for various thermal
based heat sinks for cooling of et al performance parameters. Nevertheless, the high density of metallic
electronic components: A 2016 PCM is unsuited for less weight design of heat sink.
review • Organic PCM is desirable for medium temperature application such as
Renewable and Sustainable electronic cooling
Energy Reviews (Elsevier)
6 OBJECTIVES
Development of a passive hybrid test facility to extract the heat from electronic gadgets.
To find the suitable PCM to cool the circulating fluid during solidify and supplies the heat
to cold water during resoldify.
To analysis the thermal performance of electronic component in both steady and unsteady
conditions.
To Measure the outlet water temperature and storing heat capacity of PCM for various
coolants using the experimental facility.
7 RESEARCH GAP
Many of the recent papers are encountered with PCM based fin pin and its performance
stability towards the electronic cooling. Moreover, the heat pipe based PCM cooling also
very widely used method in electronic system to extract the heat.
Among this plenty of literature survey, the circulation of liquid coolant by evaporative
closed thermosyphon method is entirely different in electronic cooling.
A very limited research work is reported in the literature with liquid coolant and PCM
based heat sink together. Hence, this work will be a disparate hybrid electronic cooling for
smart industries.
METHODOLOGY
8
9 IMPORTANCE OF THIS WORK
In this work, the widely used method called evaporative cooling is employed for
dissipating the heat from electronic gadgets.
The thermosyphon mechanism is employed for circulating the coolants throughout the test
facility. Hence, there is no need of electric power for operating the system.
Instead of fins, the PCM cooling removes the large amount of heat from vaporized coolants
and to get condensate by virtue of its high storing heat capacity.
It is a kind of passive cooling techniques. Also, there is no chance for leakage owing to
absence of prime mover which leads to stable operation to electronic devices.
10 CRITERIA FOR SELECTION OF WORKING COOLANT
LESS EFFECT ON SUB COOLING
RATE OF HEAT
REMOVAL
(Parameter 1) LOW BOILING POINT
COOLING CAPACITY
THERMAL
RESISTANCE
(Parameter 3)
HIGH SUPER HEAT NUCLEATE
BOILING
PCM CLASSIFICATION
11
ORGANIC INORGANIC
PCM PCM PCM
(Phase
Change
Material)
ORGANIC- INORGANIC
ORGANIC
EUTECTIC
-ORGANIC
INORGANIC-
INORGANIC
12
PCM SELECTION
REASON BEHIND
At high flow rate due to increase of heat
input, the vapour is compressed, thus the
pressure and velocity of working fluid in the
copper tube increases, which further causes
decrease in thermal resistance.
At high heat input, superheat will be more
which leads to nucleate boiling consequently
thermal resistance is low
22 PLAN OF ACTIVITIES THROUGH BAR DIAGRAM
JAN 2017 JULY JAN 2018 JULY JAN 2019 JULY
DURATION / – JUN 2017 – – JUN 2018 – – JUN 2019 –
ACTIVITY 2017 DEC 2017 2018 DEC 2018 2019 DEC 2019
Literature review
Course work
Defining the research problem
Defining the objectives
Material purchasing and installation
Experimentation
Validation of results
Optimization of the parameters
Research paper publication
Thesis writing
THANK YOU