South
South
South
5. Press F4 (NEZ) / input coordinate VD:____ it will change 19. E:20000.000 Press (ENT)on the keypad Data Bit set to “8”
Input coordinates of the occupied station (STN) Press F2 (Vang) to returned 20. Z:20.000 Press (ENT)on the keypad Stop bit by default “1”
6. N:20000.000 Press (ENT)on the keypad Press F3 (HD) to set another point to 21. R.HT: if needed Press (ENT) on the keypad Parity set to “NONE”
7. E:20000.000 Press (ENT)on the keypad measure 22. FOCUS THE TARGET PRISM 13. Click OK to Set
8. Z:20.000 Press (ENT)on the keypad 23. Press F1(MEAS) 14. Click Comm
MLM–
MLM–Missing Line Measurement
9. I.HT: if needed Press (ENT)on the keypad Press F1 (NEXT) Measure another point
1. Press M
10. Press F2: INPUT BACKSIGHT Press F4 (CAL) to calculate coordinate of the
2. Press F2:MEAS PROGRAM
Input point number stored on the keypad 3. Press F2:MLM occupied point.
Press ENT on the keypad to confirm 4. Create Any Filename/Press F4 (JUMP) 24. Press F4 (CAL)
F2 (LIST) searching Data in the mem 5. Press ENT on the keypad 25. Press F4 (YES)
F1 Continuous reading from 1st point 26. FINISH…
Press on the keypad (scroll up) 15. Click Download 600 Data
Press on the keypad (scroll down) F2 Point to point measurement Confirmation……..
Press ENT on the keypad to confirm 6. Press F1:MLM1(A-B A-C) DOWNLOAD DATA…
11. Press F4 (NEZ) 7. FOCUS THE TARGET PRISM TOTAL STATION SETTINGS
Input coordinates of the backsight point <STEP-1> 1. Press M on the keypad
Press F4 (ANG) use angle to set backsight 8. Press F1 (MEAS) 2. Press F3: MEMORY MGR.
9. Press F4 (SET) 3. Press so Down arrow 2X 16. Click ENTER on computer then press F4(YES)
12. N:20001.000 Press ENT on the keypad
10. Focus next target/next point 4. Press F1: DATA TRANSFER on Total Station in a second
13. E:20002.000 Press ENT on the keypad
<STEP-2> a) Press F3:COMM. PARAMETERS Ex. Data download output
Calculated Angle will display
14. Focus the target PRISM 11. Press F1 (MEAS) b) Press F1:BAUD RATE = 9600b/s
15. Press F4 [YES] Set reference angle 12. Press F4 (SET) Press F3 (-)
16. Press F3: LAYOUT 13. Display (HR,dHD,dVD,dSD) Press F4 (+) add
Input point number stored in the memory 14. Press F4 (NEXT)/measure next point c) Press ENT on the keypad to confirm
Press ENT on the keypad to confirm d) Press F2:CHAR CHECKOUT
AREA–
AREA–Calculate the Area Press F3: 8 BIT NONE
F2 (LIST) searching Data in the memory SAVE Data in any extension file like CSV,TXT,DXT
Press on the keypad (scroll up) 1. Press M on the keypad Press ENT on the keypad to confirm 17. CLICK FILE SELECT SAVE AS
2. Press F2: MEAS PROGRAM e) Press F3:PROTOCOL 18. FILENAME.csv then click SAVE
Press on the keypad (scroll down)
3. Press F3:AREA Press F2: NO ACK
Press ENT on the keypad to confirm 5 6
Press F4 (YES) F1:FILE DATA /Calculate the Area using File in the Press ENT on the keypad to confirm
17. Press F4 (NEZ) internal memory F) Press ESC on the keypad to exit Parameters
Input coordinates of the point to Layout F2:MEASURE/ Calculate the Area using direct settings
18. N :20005.000 Press ENT on the keypad
measuring 4 5. Press F1: SEND DATA
4. Press F2:MEASURE 6. Press F2: COORDINATE DATA
19. E :20004.000 Press ENT on the keypad 5. FOCUS THE TARGET PRISM 7. Press F2 (LIST)
20. Z :19.000 Press ENT on the keypad 6. Press F1 (MEAS)
3Press ENT on the keypad 8. Use on the keypad to select file.
21. R.HT:1.3____ 7. Press F4 (YES)
22. Display Calculated Angle and Distance Ex.SURVEYTECH
8. Focus the prism… Do the same (5 and 6)
23. Press F4 (NEXT) 9. Press ENT on the keypad to confirm selected file.
9. Calculated Area displayed as follows…
24. Rotate the instrument to get dHR
dHR=0°00'00" (location point)
Ex. S = 203.222 m²
RESECTION
STANDBY……OPEN SOUTH SOFTWARE
25. Press F2 (DIST) 10. Double Click the South Downloadingsoftware
1. Press M on the keypad
dHD: must set to zero”0” 11. Click Comm
2. Press F2:MEAS PROGRAM
Ex. dHD: 80.123 m 3. Press so down arrow on the keypad
dHD: 0.000 m (location point) 4. Press F4:RESECTION
26. F1 (MEAS) change the instrument reading 5. Create Any filename
27. F2 (ANG) to checked the angle 6. Press ENT on the keypad