We power the world

with innovative gas turbines


Siemens gas turbine portfolio

siemens.com/gasturbines

II
III
Gas turbines from
4 to 567 MW
The Siemens gas turbine range has been designed and
tailored to help meet our ­customers‘ ­challenges in a
dynamic market environment.
Our models range from 4 to 567 MW, fulfilling the
requirements of a wide spectrum of applications in terms
of efficiency, ­reliability, flexi­bility, and environmental
compa­­ti­bility. The products offer low lifecycle costs and
an excellent return on investment.

SGT5-9000HL 567 MW
SGT5-8000HL 481 MW

gas turbines
50 Hz SGT5-8000H 450 MW

Heavy-duty
SGT5-4000F 329 MW
SGT5-2000E 187 MW
SGT6-9000HL 388 MW
SGT6-8000H 310 MW
60 Hz
SGT6-5000F 250 MW
SGT6-2000E 117 MW
SGT-A651) 60 to 71 / 58 to 62 MW
SGT-800 48 to 57 MW

derivative gas turbines


SGT-A45 41 to 44 MW

Industrial and aero-


SGT-750 40 / 34 to 41 MW
SGT-700 33 / 34 MW
SGT-A352) 27 to 37 / 28 to 38 MW
50 Hz SGT-600 24 / 25 MW
or SGT-400 13 to 14 / 13 to 15 MW
60 Hz SGT-300 8 / 8 to 9 MW
SGT-100 5 / 6 MW
SGT-A053) 4 to 6 MW

Power generation / Mechanical drive, performance at ISO conditions


1) Industrial Trent 60 2) Industrial RB211 3) Industrial 501-K

The Dresser-Rand business, part of Siemens Power and Gas,


is committed to serving the oil and gas industry:
http://www.dresser-rand.com/products-solutions/gas-turbines/
Siemens gas turbines overview

SGT-A35 (Industrial RB211)


Heavy-duty
gas turbines SGT-A05 (Industrial 501-K) [4 to 6 MW] SGT-700
SGT-100 [5 / 6 MW] SGT-750

Industrial
SGT-300 [8 / 8 to 9 MW] SGT-A45
gas turbines
SGT-400 [13 to 15 MW] SGT-800
SGT-600 [24 / 25 MW] SGT-A65 (Industrial Trent 60)
Aeroderivative
gas turbines
50 Hz and 60 Hz
Gas turbines in the range of Gas turbines in the range of

0–25 MW 25–100 MW
SGT6-2000E [117 MW]

SGT6-5000F [250 MW]

SGT6-8000H [310 MW] 60 Hz


[27 to 37 / 28 to 38 MW] SGT6-9000HL [388 MW]

[33 / 34 MW]

[40 / 34 to 41 MW] SGT5-2000E [187 MW]

[41 to 44 MW] SGT5-4000F [329 MW]


50 Hz
[48 to 57 MW] SGT5-8000H [450 MW]

[60 to 71 / 58 to 62 MW] SGT5-8000HL [481 MW]

SGT5-9000HL [567 MW]

Gas turbines in the range of Power generation / Mechanical drive,


performance at ISO conditions

100–570 MW
All simple cycle and mechanical drive performance data in
this document are gross values at ISO ambient conditions.
All combined cycle performance data in this ­document are
net values at ISO ambient ­conditions
Table of
contents
Siemens gas turbines are suitable for a wide range
of applications:
Power generation application for utilities, independent
power producers, oil and gas, and industrial users,
such as chemicals, pulp and paper, food and beverage,
sugar, automotive, metalworking, mining, cement,
wood processing, and textiles.
Mechanical drive applications for oil and gas, and
chemical industry.

Heavy-duty gas turbines.................................................................6

Industrial gas turbines..................................................................32

Aeroderivative gas turbines...........................................................48

References...................................................................................58

Performance data overview..........................................................60


Heavy-duty
gas turbines
Siemens heavy-duty gas turbines are robust and
flexible engines, designed for large ­simple or
combined cycle power plants. They are suitable
for peak, ­inter­mediate, or base load duty, as well
as for cogeneration applications.
Customers benefit from our extensive ­vali­dation
and testing capabilites.
Our engines are proven in ­commercial ­operation
and provide outstanding efficiency.

SGT5-8000HL, SGT5-9000HL, SGT6-9000HL.....................................8

SGT5-8000H.................................................................................12

SGT6-8000H.................................................................................14

SGT5-4000F..................................................................................18

SGT6-5000F.................................................................................22

SGT5-2000E.................................................................................26

SGT6-2000E.................................................................................28
SGT5-8000HL, SGT5-9000HL,
SGT6-9000HL
Heavy-duty gas turbines
Siemens HL-class gas turbines are paving the way to the The result: A technology carrier to the next level with a
next level of efficiency and performance. combined cycle efficiency beyond 63% and a clear midterm
goal of 65%.
The evolutionary development step, derived from proven
Siemens H-class technology, combines a series of new but New Siemens HL-class consists of three engines:
already tested technologies like super-efficient internal SGT5-8000HL, SGT5-9000HL and SGT6-9000HL.
cooling features for blades and vanes and an advanced
combustion system to increase firing temperature.

References

Lincoln County CT Addition,


North Carolina, USA
Groundbreaking 2018
Turnkey plant, subject to innovative
agreement between Siemens and
Duke Energy to test and validate
advanced gas turbine technologies
over several years
Start of testing SGT6-9000HL: 2020
Tested technologies will lead to
combined cycle efficiency >63% and
a combined cycle power output of
577 MW

8
Power output: 388 – 567 MW

„„ Derived from proven Siemens H-class technology


„„ Pushing efficiency and performance to the
next level
„„ Competitive service model with
33,000 Equivalent Base Hours (EBH) / 1,250
Equivalent Starts (ES)

Today, the HL-class engines reach combined cycle efficiency of >63% with a clear Best operational flexibility due to GT ramp-up rates of
roadmap to 65% 85 MW/min and GT turn-down rates to 30%

Simple cycle power generation Physical dimensions

SGT5-8000HL SGT5-9000HL SGT6-9000HL SGT5-8000HL and SGT5-9000HL

Power output 481 MW 567 MW 388 MW Approx. weight 497,000 kg (1,095,700 lb)

Fuel Natural gas, LNG, distillate oil, other fuels on request Length 13.0 m (42.6 ft)

Frequency 50 Hz 50 Hz 60 Hz Width 5.3 m (17.4 ft)

GT ramp-up 85 MW/min 85 MW/min 85 MW/min Height 5.5 m (18.1 ft)

Gross efficiency 42.6% 42.6% 42.3%

Heat rate 8,447 kJ/kWh (8,006 Btu/kWh) 8,461 kJ/kWh (8,019 Btu/kWh) 8,519 kJ/kWh (8,074 Btu/kWh) SGT6-9000HL

Turbine speed 3,000 rpm 3,000 rpm 3,600 rpm Approx. weight 305,000 kg (672,400 lb)

Pressure ratio 24 : 1 24 : 1 24 : 1 Length 10.8 m (35.4 ft)

Exhaust mass flow 850 kg/s (1,874 lb/s) 1,000 kg/s (2,205 lb/s) 700 kg/s (1,543 lb/s) Width 5.0 m (16.4 ft)

Exhaust temperature 680 °C (1,256 °F) 680 °C (1,256 °F) 680 °C (1,256 °F) Height 4.3 m (14.1 ft)

Emissions NOX emissions: down to 2ppmvd with SCR; CO emissions: 10 ppm

Combined cycle power generation

SCC5-8000HL SCC5-8000HL SCC5-9000HL SCC5-9000HL SCC6-9000HL SCC6-9000HL


CC 1x1/1S CC 2x1 CC 1x1/1S CC 2x1 CC 1x1/1S CC 2x1

Net plant output 708 MW 1,416 MW 841 MW 1,682 MW 577 MW 1,154 MW

Net plant efficiency >63% >63% >63% >63% >63% >63%

Plant turn down 40% 40% 40% 40% 40% 40%

Net heat rate <5,714 kJ/kWh (<5,416 Btu/kWh) <5,714 kJ/kWh (<5,416 Btu/kWh)

No. of gas turbines 1 2 1 2 1 2

Pressure/reheat Triple/yes Triple/yes Triple/yes Triple/yes Triple/yes Triple/yes

Steam temperature >600 °C (>1,112 °F) >600 °C (>1,112 °F) 9


4-stage turbine
SGT5-8000HL, SGT5-9000HL, SGT6-9000HL: High cycling capability due to
fully internal air-cooled turbine
Key features section
Super-efficient internal cooling
features for blades and vanes

Single tie bolt rotor 3D four-stage turbine with


advanced materials and thermal
Proven rotor design with internal barrier coating
cooling air passages for fast (cold) All turbine vanes and blades
start and hot restart capability replace­able ­without rotor lift;
Rotor air cooler allows use of vane 1, blades 1 & 4 replaceable
proven steel disc design without cover lift

Easy rotor de-stacking on site due


to disc assembly with Hirth serration
and central tie rod

12-stage compressor

Variable inlet guide vanes and two


stages of fast-acting variable-pitch
guide vanes (VGV) for improved
part load efficiency and high load
transients
Third generation harmonized
compressor
High efficiency due to evolutionary
3D blading
All rotating compressor blades Combustion
replaceable without rotor lift or
rotor de-stacking
Advanced can annular combustion
system with dual-fuel capabilities
(12/16 combustors)

Bearings
>63% efficiency in combined cycle
Hydraulic Clearance Optimization
(HCO) for reduced degradation
and clearance losses

Flexibility Performance Serviceability


SGT5-8000H
Heavy-duty gas turbine

The SGT5-8000H offers outstanding performance and With more than 650,000 fired hours, the SGT-8000H series
high flexibility. With a gross power output of 450 MW, provides mature technology with verified reliability and
and a quick ramp-up from start to full load, the turbine availability.
offers low lifecycle costs and helps to meet fluctuating
power demands.
The turbine is the core component of highly efficient
­gas-fired power plants, designed for 665 MW at 61%
efficiency in combined cycle operation.

References

Lausward Fortuna,
Düsseldorf, Germany
Turnkey combined cycle power plant
Power output: 603.8 MW(e) and up
to 300 MW(th)
Efficiency: ~61.5%
Customer: Stadtwerke Düsseldorf AG
Scope: SCC5-8000H 1S with
1 × SGT5-8000H gas turbine

Cengiz Enerji Samsun, Turkey


Combined cycle power plant
Power output: 583 MW
Customer: Cengiz Enerji
Scope: SCC5-8000H 1S power
island with 1 x SGT5-8000H gas
turbine

Lausward Fortuna, Düsseldorf, Germany

12
Power output: 450 MW

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

The SGT5-8000H achieves an ­efficiency of 61% in combined cycle operations High operational flexibility due to world-class fast cold start
and hot restart capability

Simple cycle power generation Combined cycle power generation

Power output 450 MW Siemens combined SCC5-8000H SCC5-8000H


cycle power plant 1S / 1 × 1 2 × 1
Fuel (examples) Natural gas, LNG, sour gases, distillate oil, bio-
diesel, Arabian Super Light crude oil (ASL), ker- Net plant power output 665 MW 1,335 MW
osene, jet fuel, condensate; other fuels on re-
Net plant efficiency 61% 61%
quest
Net heat rate 5,890 kJ/kWh 5,880 kJ/kWh
Frequency 50 Hz
(5,583 Btu/kWh) (5,573 Btu/kWh)
Gross efficiency >41%
Number of gas turbines 1 2
Heat rate <8,780 kJ/kWh (<8,322 Btu/kWh)
Pressure/reheat Triple/Yes Triple/Yes
Turbine speed 3,000 rpm

Pressure ratio 21.0 : 1 Physical dimensions


Exhaust mass flow 935 kg/s (2,061 lb/s)
Approx. weight 445,000 kg (981,000 lb)
Exhaust temperature 630 °C (1,166 °F)
Length 12.6 m (41 ft)
NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas
Width 5.5 m (18 ft)
(without water injection for NOX control),
≤ 42 ppmvd at 15% O2 on fuel oil Height 5.5 m (18 ft)
(with water injection for NOX control)

13
SGT6-8000H
Heavy-duty gas turbine

The SGT6-8000H offers outstanding performance and high The turbine is the core component of highly efficient
flexibility. The air-cooled turbine with a gross power output ­ as-fired power plants, designed for 460 MW at 61% effi-
g
of 310 MW is designed for simple and fast combined cycle ciency in combined cycle operation.
integration and short start-up times.
With more than 650,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
availability.

References

Riviera Beach, Florida, USA


Supply of gas turbine packages
Power output: 3 × 274 MW
Customer: Florida Power & Light
Scope: 3 × SGT6-8000H gas
turbine packages

Andong, South Korea


Power block for combined cycle
power plant
Power output: 416 MW
Customer: Korea Southern
Power Co. Ltd.
Scope: SCC6-8000H 1S with
1 × SGT6-8000H gas turbine

Dangjin 3, South Korea

14
Power output: 310 MW

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

The blade design provides high efficiency and Valves allow for controlled cooling air supply, The SGT6-8000H can be easily integrated in
is ­designed to ensure high reliability with low to cover the needs of different o
­ perating single-shaft or multi-shaft combined cycle
outage risk conditions plants

Simple cycle power generation Combined cycle power generation

Power output 310 MW Siemens SCC6-8000H SCC6-8000H SCC6-8000H


combined 1S / 1 × 1 2 × 1 3 × 1
Fuel (examples) Natural gas, LNG, sour gases, distillate oil, bio- cycle power
diesel, Arabian Super Light crude oil (ASL), ker- plant
osene, jet fuel, condensate; other fuels on re-
quest Net plant 460 MW 930 MW 1,390 MW
power output
Frequency 60 Hz
Net plant 61% 61% 61%
Gross efficiency >40% efficiency
Heat rate <9,000 kJ/kWh (<8,530 Btu/kWh) Net heat rate 5,920 kJ/kWh 5,910 kJ/kWh 5,910 kJ/kWh
Turbine speed 3,600 rpm (5,611 Btu/kWh) (5,602 Btu/kWh) (5,602 Btu/kWh)

Pressure ratio 21.0 : 1 Number of 1 2 3


gas turbines
Exhaust mass flow 650 kg/s (1,433 lb/s)
Pressure/ Triple/Yes Triple/Yes Triple/Yes
Exhaust temperature 645 °C (1,193 °F) reheat
NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas
(without water injection for NOX control),
≤ 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control)

Physical dimensions

Approx. weight 289,000 kg (637,000 lb)

Length 10.5 m (34 ft)

Width 4.3 m (14 ft)

Height 4.3 m (14 ft)

15
Turbine

High cycling capability due to


fully internally air-cooled
SGT-8000H series: Key features turbine section
3D four-stage turbine with
advanced materials and thermal
barrier coating

Rotor Shorter outages:


All turbine vanes and blades
Proven rotor design with internal replace­able ­without rotor lift;
cooling air passages for world-class vane 1, blade 1 & 4 replaceable
fast (cold) start and hot restart without cover lift
capability
Easy rotor de-stacking on site
due to disc assembly with Hirth
serration and central tie rod

Compressor

Variable inlet guide vanes and


three stages of fast acting variable-
pitch guide vanes (VGV) for
improved part load efficiency and
high load transients
High efficiency due to evolutionary
3D blading
All rotating compressor blades
replaceable without rotor lift or
rotor de-stacking Combustion

Advanced can annular combustion


system

Bearings

Active clearance control with


Hydraulic Clearance Optimization
61% efficiency in combined cycle
(HCO) for reduced degradation
and clearance losses

Flexibility Performance Serviceability


SGT5-4000F
Heavy-duty gas turbine

The proven SGT5-4000F gas turbine has a robust design Today, around 350 turbines have been sold. The installed
with internal cooling air passages for trusted long-term fleet has accumulated an impressive fleet experience of
operation and fast start-up capability. The advanced annular over 15 million equivalent operating hours, and a fleet
combustion chamber with individually replaceable heat ­reliability of more than 99%.
shields allows for easy and fast walk-in maintenance.
Hydraulic Clearance Optimization (HCO) reduces clearance
losses to increase the gas turbine efficiency and minimize
degradation at start-up and shut down.

References

Kirishi, Russia
Supply of gas turbine packages
Power output: 800 MW
Customer: OGK-2 JSC, a subsidiary of
Gazprom Energo Holding OOO/LLC
Scope: Repowering project with
2 × SGT5-4000F gas turbine packages

Shuweihat S2, Abu Dhabi


Turnkey combined cycle power plant
Power output: 1,500 MW
Customer: Suez Energy Middle East
Scope: 2 × SCC5-4000F 2 × 1 with
4 × SGT5-4000F gas turbine packages

Al Taweelah, United Arab Emirates

18
Power output: 329 MW

„„ Proven design, large fleet


experience
„„ Easy maintenance, high availability
„„ High operational flexibility

The SGT5-4000F is a well-proven 50 Hz gas turbine Easy plant integration: Proven package For combined cycle applications, the
with an outstanding reliability and availability concepts for early power generation in simple SGT5-4000F is offered in single-shaft or
cycle operation; fast project execution multi-shaft (2 ×1) arrangements

Simple cycle power generation Combined cycle power generation

Power output 329 MW Siemens combined SCC5-4000F SCC5-4000F


cycle power plant 1S 2 × 1
Fuel (examples) Natural gas, LNG, sour gases, distillate oil, bio-
diesel, kerosene, jet fuel, condensate, naphta. Net plant power output 475 MW 950 MW
Other fuels on request
Net plant efficiency 59.7% 59.7%
Frequency 50 Hz
Net heat rate 6,030 kJ/kWh 6,030 kJ/kWh
Gross efficiency 41.0% (5,716 Btu/kWh) (5,716 Btu/kWh)

Heat rate 8,780 kJ/kWh (8,322 Btu/kWh) Number of gas 1 2


turbines
Turbine speed 3,000 rpm
Pressure/reheat Triple/Yes Triple/Yes
Pressure ratio 20.1 : 1

Exhaust mass flow 724 kg/s (1,596 lb/s)

Exhaust temperature 599 °C (1,110 °F) Physical dimensions

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas Approx. weight 318,000 kg (701,000 lb)
(without water injection for NOX control),
Length 10.8 m (35 ft)
≤ 25 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control), Width 5.2 m (17 ft)
≤ 58 ppmvd at 15% O2 on fuel oil
Height 4.8 m (16 ft)
(without water injection for NOX control)

19
Combustion

Dry-Low-NOX hybrid burners, for


low emission operation with gas-
SGT5-4000F: Key features eous and liquid fuels

Homogeneous combustor outlet


profile for minimized mechanical
Rotor and thermal turbine stress
Annular walk-in combustion
Robust design with internal
chamber with individually
cooling air passages for trusted
replaceable heat shields for easy
long term operation and fast
maintenance and short outages,
start-up capability
resulting in highest availability
Easy rotor de-stacking on site
due to disc assembly with Hirth
serration and central tie rod

Bearings

Hydraulic Clearance Optimization


(HCO) improves performance and
minimizes degradation by active
control of clearances at start-up
and shut down

Compressor
Turbine
Proven 15-stage compressor: Fast
cycling capability through fast
acting inlet guide vane High cycling capability due to
fully air-cooled hot gas path
Two additional stages of fast-act- without cooling air coolers
ing variable-pitch guide vanes
(VGV) for improved part load effi- 4 stages with film cooling and
ciency and high load transients thermal barrier coatings: Well-
balanced turbine load
All rotating compressor blades optimizes life-cycle costs
replaceable without rotor lift or
rotor de-stacking

Flexibility Performance Serviceability


SGT6-5000F
Heavy-duty gas turbine

The SGT6-5000F gas turbine offers economical power Today, more than 380 turbines have been sold.
generation with fast start-up for peak, intermediate, or The installed fleet has accumulated more than 14 million
base l­oad duty. It achieves peak values for reliability and equivalent operating hours, with a fleet reliability of over
continuous operation with highest performance values 99%.
in its class.

References

Ras Al-Khair, Saudi Arabia


Supply of gas turbine packages
Power output: 2,400 MW
Customer: Consortium comprising
Al Arrab Contracting Company,
Saudi Arabia and the Chinese
SepcoII Electric Power Construction
Corporation
Scope: 12 × SGT6-5000F gas turbine
packages

Marsh Landing, USA


Power block for open cycle power
plant
Power output: 720 MW
Customer: NRG Energy
Scope: 4 × SGT6-5000F gas turbine
packages, SPPA-T3000 control
system

La Caridad, Sonora, Mexico

22
Power output: 250 MW

„„ Highest power output for 60 Hz


F-class
„„ Fast start-up and load changing
capabilities
„„ Low emissions with NOX emissions of
≤ 9 ppmvd on gas and ≤ 25 ppmvd on oil

The SGT6-5000F offers world-class reliability and best-in-class ­emission values The SGT6-5000F is the first choice for reliable simple
or combined cycle operation in the 60 Hz market

Simple cycle power generation Combined cycle power generation

Power output 250 MW Siemens combined SCC6-5000F SCC6-5000F


cycle power plant 1 × 1 2 × 1
Fuel (examples) Natural gas, LNG, sour gases, LPG, distillate oil,
biodiesel, Arabian Super Light crude oil (ASL), Net plant power output 375 MW 750 MW
Arabian Extra Light crude oil (AXL), kerosene, jet
Net plant efficiency 59.3% 59.3%
fuel, condensate; other fuels on request
Net heat rate 6,071 kJ/kWh 6,071 kJ/kWh
Frequency 60 Hz
(5,754 Btu/kWh) (5,754 Btu/kWh)
Gross efficiency 39.3%
Number of gas turbines 1 2
Heat rate 9,160 kJ/kWh (8,682 Btu/kWh)
Pressure/reheat Triple/Yes Triple/Yes
Turbine speed 3,600 rpm

Pressure ratio 18.9 : 1


Physical dimensions
Exhaust mass flow 588 kg/s (1,296 lb/s)
Approx. weight 219,000 kg (483,000 lb)
Exhaust temperature 598°C (1,108°F)
Length 10.1 m (33 ft)
NOX emissions ≤ 9 ppmvd at 15% O2 on fuel gas
Width 4.0 m (13 ft)
(without water injection for NOX control),
≤ 25 ppmvd at 15% O2 on fuel oil Height 4.6 m (15 ft)
(with water injection for NOX control)
Combined cycle plant turn down in emissions compliance to 20% load.
Gas turbine turn down in emissions compliance
to 30% load. Fast start-up capable of generating
200 MW in 10 minutes from turning gear speed.
Gas turbine ramp rate up to 40 MW/min.

23
Turbine

4-stage turbine with proven


conventionally cast turbine
SGT6-5000F: Key features alloys

Low firing temperature for


long service intervals

Combustion

Fuel flexible and proven Ultra


Low NOX combustion system

Single digit emissions down to


30% load

Rotor

Disc assembly with Hirth serration


Compressor and central tie rod for reliable
torque transmission
Variable guide vanes for part External rotor air cooler for
load efficiency and transient constant cooling air temperature
operation across the ambient range
Blades and vanes replaceable
without rotor lift or rotor
de-stacking

Flexibility Performance Serviceability


SGT5-2000E
Heavy-duty gas turbine

The SGT5-2000E gas turbine is a proven, robust engine for high viscosity. It provides low NOX emissions, even in the
the 50 Hz market which is used in simple cycle or combined part load range.
cycle processes with or without combined heat and power.
It is suitable for all load ranges, including peak load. Today, around 300 turbines have been sold, and additionally
more than 270 turbines under license. Our installed fleet
The SGT5-2000E offers outstanding fuel flexibility. It can be has accumulated over 21 million equivalent operating
fired with low calorific gases or gases containing CO2, H2S hours. The SGT-2000E series fleet´s overall best-in-class
and N2, as well as with crude oil and other liquid fuels with ­reliability exceeds 99.5%.

References

Braemar 2, Australia
Power block for open cycle power
plant
Power output: 450 MW
Customer: ERM Power
Scope: 3 × SGT5-2000E gas turbine
packages

Geregu 2, Nigeria
Turnkey open cycle power plant
Power output: 434 MW
Customer: Niger Delta Power
Holding Company
Scope: 3 × SGT5-2000E gas turbine
packages

Az-Zour, Kuwait

26
Power output: 187 MW

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Best-in-class reliable technology; robust and flexible performance Service-friendly design and customer-focused maintenance intervals
help to keep life-cycle costs down

Simple cycle power generation Combined cycle power generation

Power output 187 MW Siemens combined SCC5-2000E SCC5-2000E


cycle power plant 1 × 1 2 × 1
Fuel (examples) Natural gas, LNG, sour gases, distillate oil,
biodiesel, crude oil, heavy fuel oil (HFO), Net plant power output 275 MW 551 MW
kerosene, jet fuel, condensate; other fuels on
Net plant efficiency 53.3% 53.3%
request
Net heat rate 6,755 kJ/kWh 6,755 kJ/kWh
Frequency 50 Hz
(6,403 Btu/kWh) (6,403 Btu/kWh)
Gross efficiency 36.5%
Number of gas turbines 1 2
Heat rate 9,863 kJ/kWh (9,349 Btu/kWh)
Pressure/reheat Dual/No Dual/No
Turbine speed 3,000 rpm

Pressure ratio 12.8 : 1

Exhaust mass flow 558 kg/s (1,230 lb/s) Physical dimensions

Exhaust temperature 536 °C (997 °F) Approx. weight 189,000 kg (417,000 lb)

NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas Length 10.3 m (34 ft)
(without water injection for NOX control),
Width 4.0 m (13 ft)
≤ 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control) Height 4.0 m (13 ft)

Note: Dimensions exclude combustion chambers.

27
SGT6-2000E
Heavy-duty gas turbine

The SGT6-2000E gas turbine is a proven, robust engine for fuels with high viscosity. It provides low NOX emissions,
the 60 Hz market which is used in simple cycle or combined even in the part load range.
cycle processes with or without combined heat and power
supply. It is suitable for all load ranges, including peak load. Today, more than 100 turbines have been sold, resulting in
The SGT6-2000E offers outstanding fuel flexibility. a fleet experience of over 8.8 million equivalent operating
hours. The SGT-2000E series fleet´s overall best-in-class
It can be fired with low calorific gases or gases containing reliability constantly exceeds 99.5%.
CO2, H2S and N2, as well as with crude oil and other liquid

References

Hsinta, Taiwan
Combined cycle power plant
Power output: 2,200 MW
Customer: Taiwan Power Company
Scope: 5 × SCC6-2000E 3 × 1 with
15 × SGT6-2000E gas turbine
packages

Shoaiba, Saudi Arabia


Most powerful and efficient crude
oil plant in the world
Power output: 1,200 MW
Customer: Saudi Electricity Company
Scope: 2 × SCC6-2000E 5 × 1 with
10 × SGT6-2000E gas turbine
packages

Charles D. Lamb Energy Center, Oklahoma, USA

28
Power output: 117 MW

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Two accessible silo combustion chambers for easy Variable inlet guide vanes (IGV); all Excellent start-up and part load behavior,
maintenance; ceramic tiles can be replaced individually compressor blades and vanes replaceable at up to 27 MW/ min ramp rate
without rotor de-stack or lift

Simple cycle power generation Combined cycle power generation

Power output 117 MW Siemens combined SCC6-2000E SCC6-2000E


cycle power plant 1 × 1 2 × 1
Fuel (examples) Natural gas, LNG, sour gases, distillate oil,
biodiesel, crude oil, heavy fuel oil (HFO), Net plant power output 174 MW 347 MW
kerosene, jet fuel, condensate; other fuels on
Net plant efficiency 52.2% 52.2%
request
Net heat rate 6,893 kJ/kWh 6,901 kJ/kWh
Frequency 60 Hz
(6,533 Btu/kWh) (6,541 Btu/kWh)
Gross efficiency 35.4%
Number of gas turbines 1 2
Heat rate 10,169 kJ/kWh (9,639 Btu/kWh)
Pressure/reheat Dual/No Dual/No
Turbine speed 3,600 rpm

Pressure ratio 12.0 : 1

Exhaust mass flow 368 kg/s (811 lb/s) Physical dimensions

Exhaust temperature 532 °C (990 °F) Approx. weight 108,000 kg (238,000 lb)

NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas Length 9.1 m (30 ft)
(without water injection for NOX control),
Width 3.3 m (11 ft)
≤ 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control) Height 3.3 m (11 ft )

Note: Dimensions exclude combustion chambers.

29
Compressor
SGT-2000E series: Key features Emission-compliant operation down to 45%
at constant exhaust temperature

Fast-acting variable inlet guide vanes for


grid frequency stabilization
All compressor blades and vanes replace-
able without rotor lift or rotor de-stacking
Combustion

Outstanding fuel flexibility, ranging


from heavy fuel oil to low calorific
Axial exhaust
gases
Two easily accessible silo combustion Cold end generator drive for
chambers for fast maintenance optimal flow pattern
Lined with ceramic tiles which can be
replaced individually

Rotor and bearings

Hydraulic Clearance Optimiza-


tion (HCO): Transient protection
of clearances for fast starts with
reduced degradation and clear-
ance losses (only available for
50 Hz version) Turbine
Built disc-type rotor with radial
4-stage turbine, blades and vanes with
Hirth serrations and central tie
Si3DTM design for enhanced
rod: Light-weight, highly rigid
performance
design with excellent start-up
performance and high cycling
capability

Rotor de-stacking capability on


site for easy maintenance
Flexibility Performance Serviceability
31
Industrial
gas turbines
The industrial gas turbine models with their compact
and rugged design make them an ideal choice for
both ­industrial power generation and mechanical
drive applications.
Their high steam-raising capabilities help achieve
overall plant efficiency of 80 percent or higher.
They are proven with more than 2,360 units sold at
small utilities, independent power producers, and in
the oil and gas industry.

SGT-800...........................................................................................34

SGT-750...........................................................................................36

SGT-700...........................................................................................38

SGT-600...........................................................................................40

SGT-400...........................................................................................42

SGT-300...........................................................................................44

SGT-100...........................................................................................46
SGT-800
Industrial gas turbine

The SGT-800 industrial gas turbine offers broad flexibility The SGT-800 combines a simple, robust design, for high
in fuels, operating conditions, maintenance concepts, reliability and easy maintenance, with high efficiency
package solutions, and ratings. and low emissions. With a proven, long-term record of
The excellent efficiency and steam-raising capability successful installations around the world, the SGT-800 is
make it outstanding in cogeneration and combined cycle an ­excellent choice for industrial or oil and gas applications.
installa­tions. The SGT-800-based power plant, designed More than 340 units have been sold with over 6 million
for flexible operation, is perfectly suited as grid support. equivalent operating hours.

References

Amata, Thailand
Combined cycle cogeneration
power plants
Customer: Amata B.Grimm
Power Limited (ABP)
Scope: 18 × SGT-800 gas turbines
and 9 × SST-400 steam turbines

Hassi R‘Mel, Algeria


Combined cycle power plant
Customer: Abengoa
Scope: 2 × SGT-800 gas turbines
and 1 × SST-900 steam turbine

SGT-800 packages at the Amata B.Grimm Power Plant, Amata Nakorn, Chonburi, Thailand

34
Power generation:
47.5 – 57.0 MW(e)
„„ Proven reliability
„„ Flexible solutions
„„ Excellent performance

SGT-800 core engine is available with different ratings Classic package – easily transported and Single lift package – short installation and com-
and standard options for hot and cold climates i­nstalled at site, easy on-site maintenance missioning time; U.S. adapted option available

Simple cycle power generation Physical dimensions

47.5 MW version 50.5 MW version 54.0 MW version 57.0 MW version Classic package Single lift package

Power output 47.5 MW(e) 50.5 MW(e) 54.0 MW(e) 57.0 MW(e) Approx. 285,000 kg 305,000 kg
weight (628,300 lb) (672,400 lb)
Fuel Natural gas, other gases within specification, liquid fuel (Diesel No.2) and dual fuel (gas and liquid).
Length 20.8 m (68 ft) 22.0 m (72 ft)
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Width 7.3 m (24 ft) 4.7 m (16 ft)
Gross efficiency 37.7% 38.3% 39.1% 40.1%
Height 6.6 m (22 ft) 5.3 m (17 ft)
Heat rate 9,547 kJ/kWh 9,389 kJ/kWh 9,206 kJ/kWh 8,970 kJ/kWh

Turbine speed 6,608 rpm 6,608 rpm 6,608 rpm 6,608 rpm

Pressure ratio 20.1 : 1 21.0 : 1 21.4 : 1 21.8 : 1

Exhaust mass flow 132.8 kg/s 134.2 kg/s 135.5 kg/s 136.6 kg/s

Exhaust temperature 541 °C (1,007 °F) 553 °C (1,027 °F) 563 °C (1,045 °F) 565 °C (1,049 °F)

NOX emissions* ≤ 15 ppmvd ≤ 15 ppmvd ≤ 15 – 17 ppmvd ≤ 20 ppmvd

SCC-800 1 × 1 combined cycle power plant

Net plant output 66.6 MW(e) 71.4 MW(e) 75.9 MW(e) 80.7 MW(e)

Net plant efficiency 53.8% 55.1% 56.0% 58.0%

Net plant heat rate 6,693 kJ/kWh 6,530 kJ/kWh 6,427 kJ/kWh 6,207 kJ/kWh

Bottoming cycle type 2PNRH 2PNRH 2PNRH 3PNRH

SCC-800 2 × 1 combined cycle power plant


The combined cycle plant SCC-800 is available based on one or multiple
Net plant output 135.4 MW(e) 143.6 MW(e) 153.7 MW(e) 163.1 MW(e) SGT-800 gas turbines. Combined cycle performance is based on two
pressure, non-reheat (2PNRH) or three pressure, non-reheat (3PNRH)
Net plant efficiency 54.7% 55.4% 56.7% 58.6% bottoming cycle.

Net plant heat rate 6,583 kJ/kWh 6,494 kJ/kWh 6,349 kJ/kWh 6,143 kJ/kWh Dimensions depending on configuration. Dimensions exclude inlet filter
housing and exhaust stack. For power generation, AC generator is included.
Bottoming cycle type 2PNRH 2PNRH 2PNRH 3PNRH
*NOX emissions at 15% O2 on fuel gas (with DLE)

35
SGT-750
Industrial gas turbine

With maximized uptime, top-class performance, and a low with different rating options due to excellent part load
environmental footprint offering the customer high lifetime capability. When running on lower load the maintenance
profitability, the SGT-750 industrial gas turbine is a perfect intervals will be extended, low emissions can be guaran-
choice for the oil and gas industry as well as industrial teed while the efficiency still is kept over 40%.
power generation.
The SGT-750 has a track record of successful performance
The modular and flexible engine enables onshore or o ­ ffshore after years in operation and verified results in various appli-
applications, mechanical drive or heat and power. cations. Units are sold for use in both power generation
It combines a robust, reliable design with high efficiency and compressor applications such as pipelines and liquefied
and low emissions. The SGT-750 offers broad flexibility natural gas (LNG).

References

Kaltex Altamira, Mexico


Combined heat and power plant
Customer: Energia MK KF, S.A. de C.V.
Scope: 1 × SGT-750 gas turbine

Greifswald Wingas, Germany


Combined heat and power plant
Customer: Industriekraftwerk
Greifs­wald GmbH, Lubmin
Scope: 1 × SGT-750 gas turbine,
auto­mation & control for landfall
station

SGT-750 combined heat and power plant in Altamira, Mexico

36
Power generation: 39.8 MW(e)
Mechanical drive: 34.0 / 41.0 MW(e)
„„ Maximized uptime
„„ High efficiency
„„ Low emissions

SGT-750 core engine with a free high-speed power Power generation package – O&G mechanical drive package for on- or
turbine also available as single lift offshore applications – also as single lift

Simple cycle power generation Mechanical drive applications

41 MW version 34 MW version

Power output 39.8 MW(e) 41.0 MW 34.0 MW

Fuel Natural gas, dual fuel, liquid fuel; options available for other gases within specification

Frequency 50/60 Hz

Gross efficiency 40.3% 41.6% 40.4%

Heat rate 8,922 kJ/kWh 8,661 kJ/kWh 8,912 kJ/kWh


1)
Turbine speed 6,100 rpm 3,050 – 6,100 – 6,405 rpm

Pressure ratio 24.3 : 1 24.3 : 1 21.9 : 1

Exhaust mass flow 115.4 kg/s 115.4 kg/s 107.5 kg/s

Exhaust temperature 468 °C (875 °F) 452 °C (845°F) 439 °C (821°F)


2)
NOX emissions <9 ppmvd <15 ppmvd <9 ppmvd

Maintenance interval (TBO) 34 kOH / 68 kOH 45 kOH / 90 kOH

Combined cycle power generation Physical dimensions

Siemens combined SCC-750 1 × 1 SCC-750 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx. 175,000 kg (385,809 lb) 76,000 kg (167,551 lb)
Net power output 51.55 MW(e) 103.74 MW(e) weight Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Net plant efficiency 53.25% 53.58% Length 20.3 m (66.6 ft) 12.8 m (40.4 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
Net heat rate 6,760 kJ/kWh 6,718 kJ/kWh Width 4.8 m (15.8 ft) 4.3 m (14.1 ft)
1) Value shown indicates 100%-design speed of drive shaft
Number of gas turbines 1 2 Height 4.1 m (13.5 ft) 4.1 m (13.5 ft)
2) NOX emissions at 15% O2 on fuel gas (with DLE)

37
SGT-700
Industrial gas turbine

Thanks to its wide fuel range capability and design features, operates with a wide range of gaseous and liquid fuels
the SGT-700 is a perfect choice for several onshore applications: on Dry Low Emission (DLE).
Industrial power generation, oil and gas power ­generation,
and mechanical drive applications. It performs well in More than 85 units have been sold with over 2 million
combined cycle plants and combined heat and power plants. operating hours. The fleet-leading gas turbine has 100,000
operating hours.
The SGT-700 gas turbine is an evolution of the proven
­SGT-600 and is specifically designed for higher power
­output. It offers easy on-site or off-site maintenance and

References

Tianjin Bohai, China


Onshore simple cycle propane
­dehydrogenation (PDH) plant
Customer: Tianjin Bohai Chemical
Industry Group
Scope: 2 × SGT-700 gas turbines and
2 × axial flow compressors

Pinghu/Satellite Energy
450 KTA, China
Onshore simple cycle propane
­dehydrogenation (PDH) plant
Customer: Zhejiang Satellite Energy
Co., Ltd
Scope: 1 × SGT-700 gas turbine coupled
with 1 × 25 MW compressor

Three SGT-700 packages for mechanical drive

38
Power generation: 32.8 MW(e)
Mechanical drive: 33.7 MW
„„ Robust, reliable design
„„ High fuel flexibility
„„ Low emissions

Maintainable, reliable, and robust twin-shaft design for mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same

Simple cycle power generation Mechanical drive applications

Power output 32.8 MW(e) 33.7 MW

Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel

Frequency 50/60 Hz

Gross efficiency 37.2% 38.2%

Heat rate 9,675 kJ/kWh 9,424 kJ/kWh

Turbine speed 6,500 rpm 3,250 – 6,500 – 6,825 rpm*

Pressure ratio 18.7 : 1 18.7 : 1

Exhaust mass flow 95.0 kg/s 95.0 kg/s

Exhaust temperature 533 °C (991 °F) 533 °C (991 °F )

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation Physical dimensions

Siemens combined SCC-700 1 × 1 SCC-700 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 45.2 MW 91.6 MW weight 169,193 kg (373,000 lb) 63,050 kg (139,000 lb)

Net plant efficiency 52.3% 53.1% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Net heat rate 6,876 kJ/kWh 6,778 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
Number of gas turbines 1 2 Height 4.0 m (13.12 ft) 4.0 m (13.12 ft)
* Value shown indicates 100%-design speed of drive shaft

39
SGT-600
Industrial gas turbine

High reliability and availability in combination with good The industrial gas turbine combines a robust, reliable
fuel flexibility and third-generation DLE makes the SGT-600 design with high fuel flexibility and low emissions.
a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation, More than 340 units have been sold with over 10 million
and mechanical drive applications. Within the IPG applications, operating hours. The fleet-leading gas turbine has 190,000
the turbine performs well in combined heat and power operating hours.
plants and combined cycle plants.

References

Bahia Blanca, Argentina


Combined heat and power
Customer: Profertil S.A.
Scope: 1 × SGT-600 gas turbine,
STC-GV (80-6) compressor, generator,
NEM heat recovery steam generator

Tiszaújváros, Hungary
Combined cycle power plant
Customer: TVK Ltd
Scope: 1 × SGT-600 gas turbine and
1 × SST-700 steam turbine

SGT-600 installation for both ­mechanical drive and power generation

40
Power generation: 24.5 MW(e)
Mechanical drive: 25.2 MW
„„ Robust, reliable design
„„ High fuel flexibility
„„ Low emissions

Maintainable, reliable, and robust twin-shaft design for ­mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same

Simple cycle power generation Mechanical drive applications

Power output 24.5 MW(e) 25.2 MW

Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel

Frequency 50/60 Hz

Gross efficiency 33.6% 34.6%

Heat rate 10,720 kJ/kWh 10,390 kJ/kWh

Turbine speed 7,700 rpm 3,850 – 7,700 – 8,085 rpm*

Pressure ratio 14.0 : 1 14.0 : 1

Exhaust mass flow 81.3 kg/s 81.3 kg/s

Exhaust temperature 543 °C (1,009 °F) 543 °C (1,009 °F)

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation Physical dimensions

Siemens combined SCC-600 1 × 1 SCC-600 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 35.9 MW(e) 73.3 MW(e) weight 149,688 kg (330,000 lb) 58,968 kg (130,000 lb)

Net plant efficiency 49.9% 50.9% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Net heat rate 7,220 kJ/kWh 7,071 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
Number of gas turbines 1 2 Height 4.0 m (13.12 ft) 4.0 m (13.12 ft)
* Value shown indicates 100%-design speed of drive shaft

41
SGT-400
Industrial gas turbine

The SGT-400 is a twin-shaft gas turbine available in With about 20 years of operating experience, the SGT-400
different configurations and power ratings to support is proven in both offshore and onshore applications.
power generation and mechanical drive applications from Over 380 units have been sold with more than 4 million
10 – 15 MW. The twin-shaft arrangement allows for com- hours operating experience. The fleet leader has accumulated
monality of parts in mixed-duty installations. about 120,000 operating hours.
The gas turbine offers the highest efficiency in its power
class, incorporating the latest aerodynamic and combustion
technologies.

References

Municipal utilities, Erlangen,


Germany
Combined cycle cogeneration
Customer: Erlanger Stadtwerke
Scope: 1 × SGT-400 gas turbine and
1 × SST-300 steam turbine

Fenice Scarlino, Italy (2013)


Combined heat and power plant
Customer: EDF Fenice/ Huntsman
Tioxide Plant
Scope: 1 × SGT-400 gas turbine

The SGT-400 is available as a factory-assembled package

42
Power generation: 12.9 / 14.3 MW(e)
Mechanical drive: 13.4 / 14.9 MW
„„ Latest aerodynamic and combustion
technology
„„ Suitable for all climates, onshore
and offshore
„„ High power-to-weight ratio

Twin-shaft design for both power generation and mechanical drive applications Compact power generation package design

Simple cycle power generation Mechanical drive applications

13 MW version 15 MW version 13 MW version 15 MW version

Power output 12.9 MW(e) 14.3 MW(e) 13.4 MW 14.9 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50/60 Hz

Gross efficiency 34.8% 35.4% 36.2% 36.8%

Heat rate 10,355 kJ/kWh 10,178 kJ/kWh 9,943 kJ/kWh 9,774 kJ/kWh

Turbine speed 9,500 rpm 9,500 rpm 4,750 – 9,500 – 9,975 rpm* 4,750 – 9,500 – 9,975 rpm*

Pressure ratio 16.8 : 1 18.9 : 1 16.8 : 1 18.9 : 1

Exhaust mass flow 39.4 kg/s 44.0 kg/s 39.4 kg/s 44.0 kg/s

Exhaust temperature 555 °C (1,031 °F) 540 °C (1,004 °F) 555 °C (1,031 °F) 540 °C (1,004 °F)

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 83,824 kg (184,800 lb) 40,142 kg (88,500 lb)

Length 14.0 m (46 ft) 7.3 m (24 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Width 3.1 m (10 ft) 3.1 m (10 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.
Height 4.3 m (14 ft) 4.3 m (14 ft)
*Value shown indicates 100%-design speed of drive shaft

43
SGT-300
Industrial gas turbine

The SGT-300 industrial gas turbine has a rugged industrial It operates on a wide range of gaseous and liquid fuels.
design that enables high efficiency, reliability, and The compact arrangement, on-site or off-site maintainability,
excellent emissions performance in a broad spectrum of and inherent reliability of the SGT-300 make it an ideal gas
applications for both power generation and mechanical turbine for the demanding oil and gas industry.
drive.
The gas turbine is a proven unit for all electrical power
­generation and cogeneration applications.

References

Over 150 units have been sold,


with more than 5.6 million equivalent
operating hours.

The SGT-300 twin-shaft version is used for mechanical drive

44
Power generation: 7.9 MW(e)
Mechanical drive: 8.4 / 9.2 MW
„„ Low maintenance requirements
„„ Low emissions
„„ Single-shaft version for power
generation, twin-shaft version for
mechancial drive applications

Twin-shaft design – evolutionary d


­ esign focused on reliability SGT-300 gas turbine package design

Simple cycle power generation Mechanical drive applications

8 MW version 9 MW version

Power output 7.9 MW(e) 8.4 MW 9.2 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz

Gross efficiency 30.6% 35.1% 35.6%

Heat rate 11,773 kJ/kWh 10,265 kJ/kWh 10,104 kJ/kWh

Turbine speed 14,010 rpm 5,750 – 11,500 – 12,075 rpm* 5,750 – 11,500 – 12,075 rpm*

Pressure ratio 13.7 : 1 13.8 : 1 14.5 : 1

Exhaust mass flow 30.2 kg/s 29.7 kg/s 30.5 kg/s

Exhaust temperature 542 °C (1,008 °F) 491 °C (916 °F) 512 °C (954 °F)

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 58,349 kg (130,844 lb) 30,409 kg (67,042 lb)

Length 11.7 m (38.5 ft) 6.9 m (22.6 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Width 2.9 m (9.4 ft) 2.9 m (9.4 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.
Height 3.5 m (11.5 ft) 3.5 m (11.5 ft)
*Value shown indicates 100%-design speed of drive shaft

45
SGT-100
Industrial gas turbine

The SGT-100 industrial gas turbine is a proven unit for The gas turbine has a rugged industrial design that enables
all electrical power generation and mechanical drive high efficiency and excellent emissions performance on a
applications. The compact arrangement, on-site or off-site wide range of gaseous and liquid fuels.
maintainability, and inherent reliability make it an ideal
gas turbine for the demanding oil and gas industry. More than 420 units have been sold with over ­25 million
operating hours. The lead package has more than 180,000
equivalent hours of operation.

References

Girvan, Scotland, UK
Combined heat and power
Customer: William Grant & Sons
distillery
Scope: 1 × SGT-100 gas turbine
­cogeneration package
Able to provide its production process
with steam and electricity, and also to
supply electricity for the region

The SGT-100 combines advanced technology with robust construction

46
Power generation: 5.05 / 5.4 MW(e)
Mechanical drive: 5.7 MW

„„ Robust and reliable product


„„ Wide range of gaseous and liquid fuels
„„ Single-shaft version for power
generation or twin-shaft version for
mechanical drive applications

Robust, reliable, maintainable single-shaft version for Common modular package design for Common modular package design for
power generation applications power generation ­mechanical drive applications

Simple cycle power generation Mechanical drive applications

5.1 MW version 5.4 MW version

Power output 5.05 MW(e) 5.4 MW(e) 5.7 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50/60 Hz

Gross efficiency 30.2% 31.0% 32.9%

Heat rate 11,914 kJ/kWh 11,613 kJ/kWh 10,948 kJ/kWh

Turbine speed 17,384 rpm 17,384 rpm 6,500 –13,000 – 13,650 rpm*

Pressure ratio 14.0 : 1 15.6 : 1 14.9 : 1

Exhaust mass flow 19.5 kg/s 20.6 kg/s 19.7 kg/s

Exhaust temperature 545 °C (1,013 °F) 531 °C (988 °F) 543 °C (1,009 °F)

NOX emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 34,927 kg (77,000 lb) 26,944 kg (59,400 lb)

Length 11.0 m (36.0 ft) 6.1 m (20.0 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Width 2.9 m (9.4 ft) 2.7 m (9.0 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.
Height 4.0 m (13.0 ft) 4.9 m (16.0 ft)
*Value shown indicates 100%-design speed of drive shaft

47
Aeroderivative
gas turbines
Originally developed for use in aviation, aeroderivative
gas turbines are flexible, ­compact, and lightweight
designs that are ideally suited for power generation
and mechanical drives in the oil and gas industry.
Their high efficiency and fast start capabilities mean
that aeroderivative gas turbines also ­perform well in
decentralized power generation applications.
With a fleet of 2,860 installed units, ­millions of
operation hours in different environments have been
generated in ­numerous reference projects.

SGT-A65 (Industrial Trent 60).................................................................50

SGT-A45................................................................................................52

SGT-A35 (Industrial RB211)....................................................................54

SGT-A05 (Industrial 501-K).....................................................................56


SGT-A65
(Industrial Trent 60)

Aeroderivative gas turbine


Designed for industrial use in power generation and The SGT-A65 is proven in many different environments
mechanical drive applications, the SGT-A65 has established including arctic, desert, tropical, and coastal in different
a new benchmark for power output, fuel eco­nomy, and applications ranging from peaking to base load, simple
cost savings. cycle, combined cycle, and mechanical drive.
The gas turbine is highly flexible, offering high power and Over 115 units have been sold with more than 1.8 million
efficiency with minimal drop-off at part-load and reduced fleet hours experience. The fleet leader has accumulated more
speed conditions. It is available with Wet Low Emission than 110,000 operating hours.
(WLE) and DLE combustion systems.

References

Bayonne, New Jersey, USA


Gas-fired power plant
Customer: Macquarie Infrastructure
Corporation
Scope: 8 × SGT-A65 (Industrial Trent
60) WLE ISI units

Dolphin Gas Project, Qatar


Integrated gas process plant
Customer: Dolphin Energy Limited
Scope: 9 × SGT-A65 (Industrial
Trent 60) gas t­ urbines and 9 × Dresser-
Rand DATUM centrifugal compressors

Three SGT-A65 units for power generation

50
Power generation: 59.6 – 70.8 MW(e)
Mechanical drive: 57.9 – 62.3 MW
„„ Most powerful, proven gas turbine in its class
„„ Flexible with high cyclic life, fast starts
„„ Modular package design for quick
in­stallation and maintenance
„„ Only 3 shaft intergrated machine on market

The SGT-A65 can cold-start to full power in less than 7 minutes and SGT-A65 package for power generation
additionally has high cyclic life

Simple cycle power generation Mechanical drive

50 Hz DLE 50 Hz DLE 60 Hz DLE 60 Hz DLE 50 Hz WLE 60 Hz WLE DLE DLE with ISI
with ISI with ISI with ISI with ISI

Power output 61.9 MW(e) 65.9 MW(e) 59.6 MW(e) 64.9 MW(e) 67.4 MW(e) 70.8 MW(e) 57.9 MW(e) 62.3 MW(e)

Fuel Natural gas only; other fuels on request Natural gas, liquid fuel, dual fuel; Natural gas Natural gas
other fuels on request

Frequency 50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz – –

Gross efficiency 43.34% 43.8% 43.2% 43.3% 41.3% 41.4% 43.6% 43.4%

Heat rate 8,307 kJ/kWh 8,228 kJ/kWh 8,330 kJ/kWh 8,311 kJ/kWh 8,724 kJ/kWh 8,696 kJ/kWh 8,250 kJ/kWh 8,290 kJ/kWh

Turbine speed 3,000 rpm 3,000 rpm 3,600 rpm 3,600 rpm 3,000 rpm 3,600 rpm 3,400 rpm 3,400 rpm

Pressure ratio 38.1 : 1 39.6 : 1 36.6 : 1 38.0 : 1 39.9 : 1 39.3 : 1 34.3 : 1 34.3 : 1

Exhaust mass flow 171 kg/s 178 kg/s 165 kg/s 171 kg/s 178 kg/s 176 kg/s 157.7 kg/s 162.8 kg/s

Exhaust temperature 441 °C (826 °F) 431°C (808 °F) 443 °C (829 °F) 437 °C (819 °F) 431 °C (808 °F) 447 °C (837 °F) 447°C (837 °F) 441 °C (826 °F)

NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with WLE and DLE) ≤ 25 ppmvd at 15% O2 on fuel gas

Combined cycle power generation Physical dimensions

DLE 1x1 DLE 2x1 DLE with ISI 1x1 DLE with ISI 2x1 Power generation Mechanical drive
package package
Note: SGT-A65 WLE – water injected. ISI – Inlet Spray
Net power output 73.0 MW(e) 147.0 MW(e) 83.0 MW(e) 166.8 MW(e) Approx. 190,512 kg 106,000 kg Intercooling (wet compression water to the compressor).
weight (420,007 lb) (233,690 lb) WLE also available without ISI
Net plant efficiency 54.6% 55.0% 54.2% 54.4%
WLE (with and without ISI) performance for Mechanical Drive and Com-
Length 26.6 m (97.1 ft) 12.4 m (40.7 ft) bined Cycle available upon request
Net heat rate 6,593 kJ/kWh 6,546 kJ/kWh 6,648 kJ/kWh 6,617 kJ/kWh
Width 4.6 m (15.1 ft) 4.7 m (15.4 ft) For power generation, AC generator is included, dimensions include inlet
Pressure/reheat Dual/No Dual/No Dual/No Dual/No filter housing, exclude exhaust stack. For mechanical drive, driven equip-
Height 5.2 m (17.1 ft) 6.4 m (21.0 ft) ment is excluded, dimensions exclude inlet filter housing and exhaust
stack.

51
SGT-A45
Aeroderivative gas turbine
A dependable supply of electricity is at the very base of Based on proven aeroderivative gas turbine technology, the
good living standards and economic growth. Several areas SGT-A45 achieves the highest power density and fuel effi-
of the world continue to require the fast deployment of ciency of all mobile power plants on the market. It can
power solutions to quickly restore and upgrade a damaged operate at either 50 Hz or 60 Hz and offers a highly flexible
or inadequate infrastructure, supporting developing econo- solution for a wide range of applications.
mies or emergency relief.
The SGT-A45 mobile unit is offered with complete fast-
With site installation in less than 2 weeks and an outstanding track power plant solutions.
output of up to 44 MW(e), the SGT-A45 mobile gas turbine unit
offers a cost-effective, dependable solution to these needs.

References

On-site installation of 4 SGT-A45 mobile units

52
Power generation: up to 44.0 MW(e)

„„ The world's most powerful and fuel-


efficient mobile gas turbine
„„ Great flexibility in operation
„„ Highly mobile on land, air, sea
„„ Performance optimized for hot climates

The SGT-A45 core engine is derived directly from the SGT-A65 (Industrial The SGT-A45 mobile unit consists of 3 trailer-mounted, self-contained
Trent 60) by removing the low-pressure compressor module modules to reduce installation time to under 2 weeks

Simple cycle power generation / 50 Hz Simple cycle power generation / 60 Hz

ISO conditions Hot climate ISO conditions Hot climate


(15°C ambient) (30°C ambient) (15°C ambient) (30°C ambient)

Power output 41.0 MW(e) 39.3 MW(e) 44.0 MW 39.6 MW

Fuel Dual fuel (gas and liquid)

Frequency 50 Hz 50 Hz 60 Hz 60 Hz

Electrical efficiency 39.0% 38.4% 40.4% 39.5%

Low emissions option Water injection Water injection Water injection Water injection

Turbine speed 3,000 rpm 3,000 rpm 3,600 rpm 3,600 rpm

Pressure ratio 27.7 : 1 26.7 : 1 27.9 : 1 25.8 : 1

Exhaust mass flow 127 kg/s 120 kg/s 126 kg/s 116 kg/s

Exhaust temperature 477 °C (891°F) 501 °C (934 °F) 483 °C (901 °F) 498 °C (928 °F)

NOX emissions ≤ 15 ppmvd (gas fuel) / 42 ppvm (liquid fuel) with optional water injection

Physical dimensions and weight

Mobile unit as installed

Approx. weight 95,000 kg (210,000 lb)

Length 37.1 m (121.7 ft)

Width 7.7 m (25 ft)


Note: Nominal performance shown.
Height 8.4 m (27.6 ft) Performance guarantees are only provided in individual project proposals
based on specifications given.

53
SGT-A35
(Industrial RB211)

Aeroderivative gas turbine


With class-leading reliability and availability, the SGT-A35 industrial, marine and aerospace service, it offers class-leading
(Industrial RB211) is your proven, dependable choice in power density for power generation and mechanical drive
power generation and mechanical drive applications. It is applications with two variants rated at 34 MW and 38 MW.
qualified to meet the stringent standards of the oil and gas
The efficient SGT-A35 gas turbine, with Rolls-Royce aero
industry and has earned a solid reputation in both onshore
engine technology, is integrated in a compact, lightweight
and offshore service.
and highly maintainable package designed for oil and gas
The GT30 variant is the latest evolution in a portfolio applications by Dresser-Rand, now a Siemens business.
continuously improved over 40 years of technology
The SGT-A35 has accumulated over 38 million equivalent
development. Utilizing components already proven in
operating hours, with over 800 units sold.

References

Lula (Tupi) and Guará


­oilfields, offshore Brazil
Power generation in eight offshore
oil and gas FPSO vessels
Customer: Petrobras
Scope: 32 × SGT-A35 (Industrial RB211
GT62) generating sets

West-East Gas Pipeline,


China
Gas pipeline compression station
Customer: PetroChina
Scope: Four phases for total of over
30 x SGT-A35 (Industrial RB211 G62)
gas turbine packages driving centrifu-
gal pipeline compressors

Two SGT-A35 (Industrial RB211-GT30) packages on an FPSO vessel

54
Power generation: 27.2 – 37.4 MW(e)
Mechanical drive: 27.9 – 38.1 MW

„„ Proven track record in the O&G market


„„ Several variants to meet different
power needs
„„ Lightweight, compact, modular package
design to maximize power density

The SGT-A35 is a two-spool gas generator aerodynamically coupled to Modular package design to meet specifications of a wide range of
a free power turbine applications

Simple cycle power generation Physical dimensions3)

SGT-A35 (G62) SGT-A35 (GT62) SGT-A35 (GT61) SGT-A35 (GT30 SGT-A35 (GT30 SGT-A35 (GT30 Power generation Mechanical drive
DLE DLE DLE 34 MW) DLE 60 Hz 1) 34 MW) 60 Hz1) 38 MW) 60 Hz1) package package
Power output 27.2 MW(e) 29.9 MW(e) 32.1 MW(e) 32.5 MW(e) 33.2 MW(e) 37.4 MW(e) Approx. 150,000 kg 99,000 kg
2)
weight (330,693 lb) (218,257 lb)
Fuel Natural gas, liquid fuel, dual fuel
Length 16.0 m (52.49 ft) 9.2 m (30.2 ft)
Gross efficiency 50/60 Hz 50/60 Hz 50/60 Hz 60 Hz 60 Hz 60 Hz
Width 3.3 m (10.83 ft) 4 m (13.1 ft)
Frequency 36.4% 37.5% 39.3% 38.3% 38.5% 39.7%
Height 5.4 m (17.72 ft) 5 m (16.4 ft)
Heat rate 9,904 kJ/kWh 9,589 kJ/kWh 9,159 kJ/kWh 9,397 kJ/kWh 9,362 kJ/kWh 9,074 kJ/kWh

Turbine speed 4,800 rpm 4,800 rpm 4,850 rpm 3,600 rpm 3,600 rpm 3,600 rpm 1) Data for 50 Hz not shown, available at www.siemens.com/gasturbines

Pressure ratio 20.6 : 1 21.7 : 1 21.6 : 1 22.3 : 1 22.7 : 1 25.0 : 1 2) Other fuels on request; automatic changeover from primary to sec-
ondary fuel at any load
Exhaust mass flow 91.0 kg/s 95.0 kg/s 94.0 kg/s 97.9 kg/s 98.9 kg/s 109.1 kg/s 3) For power generation, AC generator is included. Weight is for the
installed unit, dry. Dimensions are for the main package enclosure.
Exhaust temperature 501 °C (934 °F) 503 °C (937 °F) 509 °C (948 °F) 500° C (932 °F) 501 °C (933 °F) 487 °C (909 °F) For mechanical drive, driven equipment is excluded.

DLE NOx emissions <25 ppmvd at 15% O2 on fuel gas

Mechanical drive applications


SGT-A35 SGT-A35 SGT-A35 SGT-A35 SGT-A35 SGT-A35 SGT-A35 SGT-A35 SGT-A35
(GT30 34 MW) (GT30 34 MW) DLE (GT30 38 MW) (G62) DLE (G62) (GT62) DLE (GT62) (GT61) DLE (GT61)
Power output 33.7 MW 33.1 MW 38.1 MW 27.9 MW 29.1 MW 30.6 MW 30.9 MW 33.0 MW 33.8 MW

Fuel Natural gas, liquid fuel, dual fuel2) Natural gas, liquid fuel, dual fuel1)

Efficiency 39.1% 38.9% 40.3% 37.3% 37.7% 38.5% 38.6% 40.3% 40.4%

Heat rate 9,219 kJ/kWh 9,255 kJ/kWh 8,938 kJ/kWh 9,648 kJ/kWh 9,540 kJ/kWh 9,336kJ/kWh 9,338 kJ/kWh 8,922 kJ/kWh 8,912 kJ/kWh

Drive shaft speed 3,429 rpm 3,429 rpm 3,429 rpm 4,800 rpm 4,800 rpm 4,800 rpm 4,800 rpm 4,850 rpm 4,850 rpm

Pressure ratio 22.8 : 1 22.3 : 1 25.2 : 1 20.6 : 1 21.3 : 1 21.7 : 1 22.0 : 1 21.6 : 1 22.1 : 1

Exhaust mass flow 99.3 kg/s 98.2 kg/s 109.5 kg/s 91.0 kg/s 93.0 kg/s 95.0 kg/s 96.0 kg/s 94.0 kg/s 95.0 kg/s

Exhaust temperature 501° C (934° F) 500° C (932° F) 488° C (910° F) 501 °C (934 °F) 501 °C (934 °F) 503 °C (937 °F) 503 °C (937 °F) 510° C (950° F) 509° C (948° F)

55
SGT-A05
(Industrial 501-K)

Aeroderivative gas turbine


Based on proven aeroderivative design, the SGT-A05 deliv- fuel, steam, and water injection. DLE technology is also
ers high efficiency and outstanding reliability for power available.
generation applications like cogeneration and emergency
power. The gas turbine offers rugged, easy-to-maintain More than 2,100 SGT-A05 gas turbines have been sold for
performance due to features such as co-engine mounted industrial use to more than 500 customers in 53 countries,
auxiliary equipment. accumulating an impressive 120 million operating hours
since its introduction in 1963.
The gas turbine engine is designed to operate on a wide
variety of fuels. The fuel system operations include dual

References

Grampian, Scotland
Combined heat and power plant
Customer: National Health Service,
Foresterhill Health Campus
Scope: 1 × SGT-A05 (Industrial 501-K)
gas turbine

Power station at Mitchelstown, Ireland

56
Power generation: 4.0 – 5.8 MW(e)

„„ More than 1,675 gas turbines supplied


„„ Full power available within 60 seconds
„„ High electrical and cycle efficiency

The SGT-A05 has black start and hot start capability. Full power is available SGT-A05 on a test stand at Siemens facility in Mount
within 60 seconds ­ ernon, Ohio, USA
V

Simple cycle power generation

SGT-A05 (KB5S) SGT-A05 (KB7S) SGT-A05 (KB7HE)

Power output 4.0 MW(e) 5.4 MW(e) 5.8 MW(e)

Fuel Natural gas, liquid fuel, duel fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50/60 Hz 50/60 Hz

Gross efficiency 29.7% 32.3% 33.2%

Heat rate 12,137 kJ/kWh 11,152 kJ/kWh 10,848 kJ/kWh

Turbine speed 14,200 rpm 14,600 rpm 14,600 rpm

Pressure ratio 10.3 : 1 13.9 : 1 14.0 : 1

Exhaust mass flow 15.4 kg/s 21.3 kg/s 21.4 kg/s

Exhaust temperature 560 °C (1,040 °F) 494 °C (921 °F) 522 °C (972 °F)

NOX emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package

Approx. weight 35,000 kg (77,000 lb)

Length 9 m (29.5 ft)

Width 2.7 m (8.9 ft)


Note:
Height 3.1 m (10.2 ft) Dimensions exclude inlet filter housing and exhaust stack.
For power generation, AC generator is included.

57
Heavy-duty
gas turbines

Industrial
gas turbines

Aeroderivative
gas turbines
References

Siemens gas turbines are operating in more


than 60 countries.
We provide proven technology with more
than 7,000 installed heavy-duty, industrial,
and aeroderivative gas turbines.
Performance data overview
Mechanical drive applications (metric units)

Power output Gross efficiency Heat rate Drive shaft speed* Pressure ratio Exhaust mass flow Exhaust temperature

SGT-750 (41 MW) 41.0 MW 41.6% 8,661 kJ/kWh 3,050 – 6,100 – 6,405 rpm 24.3 : 1 115.4 kg/s 468° C
SGT-750 (34 MW) 34.0 MW 40.4% 8,912 kJ/kWh 3,050 – 6,100 – 6,405 rpm 21.9 : 1 107.5 kg/s 439° C

SGT-700 33.7 MW 38.2% 9,424 kJ/kWh 3,250 – 6,500 – 6,825 rpm 18.7 : 1 95.0 kg/s 533° C

SGT-600 25.2 MW 34.6% 10,390 kJ/kWh 3,850 – 7,700 – 8,085 rpm 14.0 : 1 81.3 kg/s 543° C

SGT-400 (15 MW) 14.9 MW 36.8% 9,774 kJ/kWh 4,750 – 9,500 – 9,975 rpm 18.9 : 1 44.0 kg/s 540° C

SGT-400 (13 MW) 13.4 MW 36.2% 9,943 kJ/kWh 4,750 – 9,500 – 9,975 rpm 16.8 : 1 39.4 kg/s 555° C

SGT-300 (9 MW) 9.2 MW 35.6% 10,104 kJ/kWh 5,750 – 11,500 – 12,075 rpm 14.5 : 1 30.5 kg/s 512° C

SGT-300 (8 MW) 8.4 MW 35.1% 10,265 kJ/kWh 5,750 – 11,500 – 12,075 rpm 13.8 : 1 29.7 kg/s 491° C

SGT-100 5.7 MW 32.9% 10,948 kJ/kWh 6,500 – 13,000 – 13,650 rpm 14.9 : 1 19.7 kg/s 543° C

SGT-A65 DLE 57.9 MW 43.6% 8,250 kJ/kWh 3,400 rpm 34.3 : 1 157.7 kg/s 447° C

SGT-A65 DLE with ISI 62.3 MW 43.4% 8,290 kJ/kWh 3,400 rpm 34.3 : 1 162.8 kg/s 441° C

SGT-A35 (GT30 38 MW) 38.1 MW 40.3% 8,938 kJ/kWh 2,400 – 3,429 – 3,600 rpm 25.2 : 1 109.5 kg/s 488° C

SGT-A35 (GT30 34 MW) 33.7 MW 39.1% 9,219 kJ/kWh 2,400 – 3,429 – 3,600 rpm 22.8 : 1 99.3 kg/s 501° C

SGT-A35 (GT30 34 MW) DLE 33.1 MW 38.9% 9,255 kJ/kWh 2,400 – 3,429 – 3,600 rpm 22.3 : 1 98.2 kg/s 500° C

SGT-A35 (GT61) 33.8 MW 40.4% 8,912 kJ/kWh 3,153 – 4,850 – 5,093 rpm 22.1 : 1 95.0 kg/s 510° C

SGT-A35 (GT61) DLE 33.0 MW 40.3% 8,922 kJ/kWh 3,153 – 4,850 – 5,093 rpm 21.6 : 1 94.0 kg/s 510° C

SGT-A35 (GT62) 30.9 MW 38.6% 9,336 kJ/kWh 3,120 – 4,800 – 5,040 rpm 22.0 : 1 96.0 kg/s 503° C

SGT-A35 (GT62) DLE 30.6 MW 38.5% 9,341 kJ/kWh 3,120 – 4,800 – 5,040 rpm 21.7 : 1 96.0 kg/s 503° C

SGT-A35 (G62) 29.1 MW 37.7% 9,540 kJ/kWh 3,120 – 4,800 – 5,040 rpm 21.3 : 1 93.0 kg/s 501° C

SGT-A35 (G62) DLE 27.9 MW 37.3% 9,648 kJ/kWh 3,120 – 4,800 – 5,040 rpm 20.6 : 1 91.0 kg/s 501° C

60 * Values shown indicate 100%-design speed of drive shaft


Mechanical drive applications (imperial units)

Power output Gross efficiency Heat rate Drive shaft speed* Pressure ratio Exhaust mass Exhaust temperature
SGT-750 (41 MW) 54,994 hp 41.6% 6,121 Btu/hph 8,209 Btu/kWh 3,050 - 6,100 - 6,405 rpm 24.3 : 1 253.5 lb/s 875° F
SGT-750 (34 MW) 45,595 hp 40.4% 6,299 Btu/hph 8,447 Btu/kWh 3,050 – 6,100 – 6,405 rpm 21.9 : 1 236.9 lb/s 822° F

SGT-700 45,151 hp 38.2% 6,661 Btu/hph 8,932 Btu/kWh 3,250 - 6,500 - 6,825 rpm 18.7 : 1 209.0 lb/s 991° F

SGT-600 33,847 hp 34.6% 7,344 Btu/hph 9,848 Btu/kWh 3,850 - 7,700 - 8,085 rpm 14.0 : 1 179.2 lb/s 1,009° F

SGT-400 (15 MW) 20,006 hp 36.8% 6,908 Btu/hph 9,264 Btu/kWh 4,750 - 9,500 - 9,975 rpm 18.9 : 1 97.0 lb/s 1,004° F

SGT-400 (13 MW) 18,000 hp 36.2% 7,028 Btu/hph 9,424 Btu/kWh 4,750 - 9,500 - 9,975 rpm 16.8 : 1 86.8 lb/s 1,031° F

SGT-300 (9 MW) 12,388 hp 35.6% 7,141 Btu/hph 9,577 Btu/kWh 5,750 - 11,500 - 12,075 rpm 14.5 : 1 67.2 lb/s 954° F

SGT-300 (8 MW) 11,216 hp 35.1% 7,255 Btu/hph 9,729 Btu/kWh 5,750 - 11,500 - 12,075 rpm 13.8 : 1 65.5 lb/s 916° F

SGT-100 7,640 hp 32.9% 7,738 Btu/hph 10,377 Btu/kWh 6,500 - 13,000 - 13,650 rpm 14.9 : 1 43.4 lb/s 1,009° F

SGT-A65 DLE 77,645 hp 43.6% 5,831 Btu/hph 7,819 Btu/kWh 3,400 rpm 34.3 : 1 347.7 lb/s 837° F

SGT-A65 DLE with ISI 83,545 hp 43.4% 5,859 Btu/hph 7,857 Btu/kWh 3,400 rpm 34.3 : 1 358.9 lb/s 825° F

SGT-A35 (GT30 38 MW) 51,092 hp 40.3% 6,317 Btu/hph 8,471 Btu/kWh 2,400 – 3,429 – 3,600 rpm 25.2 : 1 241.4 lb/s 910° F

SGT-A35 (GT30 34 MW) 45,195 hp 39.1% 6,516 Btu/hph 8,737 Btu/kWh 2,400 – 3,429 – 3,600 rpm 22.8 : 1 218.9 lb/s 934° F

SGT-A35 (GT30 34 MW) DLE 44,387 hp 38.9% 6,541 Btu/hph 8,772 Btu/kWh 2,400 – 3,429 – 3,600 rpm 22.3 : 1 216.5 lb/s 932° F

SGT-A35 (GT61) 45,316 hp 40.4% 6,299 Btu/hph 8,447 Btu/kWh 3,153 – 4,850 – 5,093 rpm 22.1 : 1 209.0 lb/s 950° F

SGT-A35 (GT61) DLE 44,230 hp 40.3% 6,307 Btu/hph 8,456 Btu/kWh 3,153 – 4,850 – 5,093 rpm 21.6 : 1 207.0 lb/s 950° F

SGT-A35 (GT62) 41,495 hp 38.6% 6,599 Btu/hph 8,849 Btu/kWh 3,120 – 4,800 – 5,040 rpm 22.0 : 1 211.9 lb/s 937° F

SGT-A35 (GT62) DLE 41,084 hp 38.5% 6,602 Btu/hph 8,854 Btu/kWh 3,120 – 4,800 – 5,040 rpm 21.7 : 1 209.0 lb/s 937° F

SGT-A35 (G62) 39,075 hp 37.7% 6,743 Btu/hph 9,042 Btu/kWh 3,120 – 4,800 – 5,040 rpm 21.3 : 1 205.9 lb/s 934° F

SGT-A35 (G62) DLE 37,465 hp 37.3% 6,819 Btu/hph 9,145 Btu/kWh 3,120 – 4,800 – 5,040 rpm 20.6 : 1 201.0 lb/s 934° F

* Values shown indicate 100%-design speed of drive shaft 61


Simple cycle power generation (metric units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT5-9000HL 567 MW 50 Hz 42.6% 8,461 kJ/kWh 3,000 rpm 24.0 : 1 1,000 kg/s 680° C
SGT6-9000HL 388 MW 60 Hz 42.3% 8,519 kJ/kWh 3,600 rpm 24.0 : 1 700 kg/s 680° C
SGT5-8000HL 481 MW 50 Hz 42.6% 8,447 kJ/kWh 3,000 rpm 24.0 : 1 850 kg/s 680° C
SGT5-8000H 450 MW 50 Hz > 41% < 8,780 kJ/kWh 3,000 rpm 20.0 : 1 935.0 kg/s 630° C
SGT6-8000H 310 MW 60 Hz > 40% < 9,000 kJ/kWh 3,600 rpm 20.0 : 1 650.0 kg/s 645° C
SGT5-4000F 329 MW 50 Hz 41.0% 8,780 kJ/kWh 3,000 rpm 20.1 : 1 724.0 kg/s 599° C
SGT6-5000F 250 MW 60 Hz 39.3% 9,160 kJ/kWh 3,600 rpm 18.9 : 1 588.0 kg/s 598° C
SGT5-2000E 187 MW 50 Hz 36.5% 9,863 kJ/kWh 3,000 rpm 12.8 : 1 558.0 kg/s 536° C
SGT6-2000E 117 MW 60 Hz 35.4% 10,169 kJ/kWh 3,600 rpm 12.0 : 1 368.0 kg/s 532° C
SGT-800 (57.0 MW) 57.0 MW(e) 50/60 Hz 40.1% 8,970 kJ/kWh 6,608 rpm 21.8 : 1 136.6 kg/s 565° C
SGT-800 (54.0 MW) 54.0 MW(e) 50/60 Hz 39.1% 9,206 kJ/kWh 6,608 rpm 21.4 : 1 135.5 kg/s 563° C
SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 9,389 kJ/kWh 6,608 rpm 21.0 : 1 134.2 kg/s 553° C
SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,547 kJ/kWh 6,608 rpm 20.1 : 1 132.8 kg/s 541° C
SGT-750 39.8 MW(e) 50/60 Hz 40.3% 8,922 kJ/kWh 6,100 rpm 24.3 : 1 115.4 kg/s 468° C
SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,675 kJ/kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C
SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,720 kJ/kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C
SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 10,178 kJ/kWh 9,500 rpm 18.9 : 1 44.0 kg/s 540° C
SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 10,355 kJ/kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C
SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,773 kJ/kWh 14,010 rpm 13.7 : 1 30.2 kg/s 542° C
SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,612 kJ/kWh 17,384 rpm 15.6 : 1 20.6 kg/s 531° C
SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,913 kJ/kWh 17,384 rpm 14.0 : 1 19.5 kg/s 545° C

62
Simple cycle power generation (imperial units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT5-9000HL 567 MW 50 Hz 42.6% 8,019 Btu/kWh 3,000 rpm 24.0 : 1 2,204 lb/s 1256° F
SGT6-9000HL 388 MW 60 Hz 42.3% 8,074 Btu/kWh 3,600 rpm 24.0 : 1 1,543 lb/s 1256° F
SGT5-8000HL 481 MW 50 Hz 42.6% 8,222 Btu/kWh 3,000 rpm 24.0 : 1 1,873 lb/s 1256° F
SGT5-8000H 450 MW 50 Hz > 41% < 8,322 Btu/kWh 3,000 rpm 20.0 : 1 2,061.0 lb/s 1,166° F
SGT6-8000H 310 MW 60 Hz > 40% < 8,530 Btu/kWh 3,600 rpm 20.0 : 1 1,433.0 lb/s 1,193° F
SGT5-4000F 329 MW 50 Hz 41.0% 8,322 Btu/kWh 3,000 rpm 20.1 : 1 1,596.0 lb/s 1,110° F
SGT6-5000F 250 MW 60 Hz 39.3% 8,682 Btu/kWh 3,600 rpm 18.9 : 1 1,296.0 lb/s 1,108° F
SGT5-2000E 187 MW 50 Hz 36.5% 9,349 Btu/kWh 3,000 rpm 12.8 : 1 1,230.0 lb/s 997° F
SGT6-2000E 117 MW 60 Hz 35.4% 9,639 Btu/kWh 3,600 rpm 12.0 : 1 811.0 lb/s 990° F
SGT-800 (57.0 MW) 57.0 MW(e) 50/60 Hz 40.1% 8,502 Btu/kWh 6,608 rpm 21.8 : 1 301.2 lb/s 1,049° F
SGT-800 (54.0 MW) 54.0 MW(e) 50/60 Hz 39.1% 8,725 Btu/kWh 6,608 rpm 21.4 : 1 298.7 lb/s 1,045° F
SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 8,899 Btu/kWh 6,608 rpm 21.0 : 1 295.8 lb/s 1,027° F
SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,048 Btu/kWh 6,608 rpm 20.1 : 1 292.8 lb/s 1,007° F
SGT-750 39.8 MW(e) 50/60 Hz 40.3% 8,456 Btu/kWh 6,100 rpm 24.3 : 1 253.5 lb/s 875° F
SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,170 Btu/kWh 6,500 rpm 18.7 : 1 209.0 lb/s 991° F
SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,161 Btu/kWh 7,700 rpm 14.0 : 1 179.2 lb/s 1,009° F
SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 9,647 Btu/kWh 9,500 rpm 18.9 : 1 97.7 lb/s 1,004° F
SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 9,815 Btu/kWh 9,500 rpm 16.8 : 1 86.8 lb/s 1,031° F
SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,158 Btu/kWh 14,010 rpm 13.7 : 1 66.6 lb/s 1,008° F
SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,007 Btu/kWh 17,384 rpm 15.6 : 1 45.4 lb/s 988° F
SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,292 Btu/kWh 17,384 rpm 14.0 : 1 43.1 lb/s 1,013° F

63
Simple cycle power generation (metric units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT-A65 50 Hz DLE 61.9 MW(e) 50 Hz 43.34% 8,307 kJ/kWh 3,000 rpm 38.1 : 1 171.0 kg/s 441° C
SGT-A65 50 Hz DLE with ISI 65.9 MW(e) 50 Hz 43.8% 8,228 kJ/kWh 3,000 rpm 39.6 : 1 178.0 kg/s 431° C
SGT-A65 60 Hz DLE 59.6 MW(e) 60 Hz 43.2% 8,330 kJ/kWh 3,600 rpm 36.6 : 1 165.0 kg/s 443° C
SGT-A65 60 Hz DLE with ISI 64.9 MW(e) 60 Hz 43.3% 8,311 kJ/kWh 3,600 rpm 38.0 : 1 171.0 kg/s 437° C
SGT-A65 50 Hz WLE with ISI 67.4 MW(e) 50 Hz 41.3% 8,724 kJ/kWh 3,000 rpm 39.9 : 1 178.0 kg/s 431° C
SGT-A65 60 Hz WLE with ISI 70.8 MW(e) 60 Hz 41.4% 8,696 kJ/kWh 3,600 rpm 39.3 : 1 176.0 kg/s 447° C
SGT-A45 50 Hz (at 15 °C ambient) 41.0 MW(e) 50/60 Hz 39.0% 27.7 : 1 127.0 kg/s 477° C
SGT-A45 50 Hz (at 30 °C ambient) 39.3 MW(e) 50/60 Hz 38.4% 26.7 : 1 120.0 kg/s 501° C
SGT-A45 60 Hz (at 15 °C ambient) 44.0 MW(e) 50/60 Hz 40.4% 27.9 : 1 126.0 kg/s 483° C
SGT-A45 60 Hz (at 30 °C ambient) 39.6 MW(e) 50/60 Hz 39.5% 25.8 : 1 116.0 kg/s 498° C
SGT-A35 (GT30 38 MW) 50 Hz 36.6 MW(e) 50 Hz 38.7% 9,298 kJ/kWh 3,000 rpm 25.4 : 1 111.0 kg/s 489 °C
SGT-A35 (GT30 34 MW) 50 Hz 32.2 MW(e) 50 Hz 37.5% 9,611 kJ/kWh 3,000 rpm 22.9 : 1 99.8 kg/s 503 °C
SGT-A35 (GT30 34 MW) DLE 50 Hz 31.9 MW(e) 50 Hz 37.3% 9,644 kJ/kWh 3,000 rpm 22.6 : 1 99.2 kg/s 504° C
SGT-A35 (GT30 38 MW) 60 Hz 37.4 MW(e) 60 Hz 39.7% 9,074 kJ/kWh 3,600 rpm 25.0 : 1 109.1 kg/s 487 °C
SGT-A35 (GT30 34 MW) 60 Hz 33.2 MW(e) 60 Hz 38.5% 9,362 kJ/kWh 3,600 rpm 22.7 : 1 98.9 kg/s 501 °C
SGT-A35 (GT30 34 MW) DLE 60 Hz 32.5 MW(e) 60 Hz 38.3% 9,397 kJ/kWh 3,600 rpm 22.3 : 1 97.9 kg/s 500° C
SGT-A35 (GT61) DLE 32.1 MW(e) 50/60 Hz 39.3% 9,159 kJ/kWh 4,850 rpm 21.6 : 1 94.0 kg/s 509° C
SGT-A35 (GT62) DLE 29.9 MW(e) 50/60 Hz 37.5% 9,589 kJ/kWh 4,800 rpm 21.7 : 1 95.0 kg/s 503° C
SGT-A35 (G62) DLE 27.2 MW(e) 50/60 Hz 36.4% 9,904 kJ/kWh 4,800 rpm 20.6 : 1 91.0 kg/s 501° C
SGT-A05 (KB7HE) 5.8 MW(e) 50/60 Hz 33.2% 10,848 kJ/kWh 14,600 rpm 14.0 : 1 21.4 kg/s 522° C
SGT-A05 (KB7S) 5.4 MW(e) 50/60 Hz 32.3% 11,152 kJ/kWh 14,600 rpm 13.9 : 1 21.3 kg/s 494° C
SGT-A05 (KB5S) 4.0 MW(e) 50/60 Hz 29.7% 12,137 kJ/kWh 14,200 rpm 10.3 : 1 15.4 kg/s 560° C

64
Simple cycle power generation (imperial units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT-A65 DLE 61.9 MW(e) 50 Hz 43.34% 7,874 Btu/kWh 3,000 rpm 38.1 : 1 377.0 lb/s 826° F
SGT-A65 DLE with ISI 65.9 MW(e) 50 Hz 43.8% 7,799 Btu/kWh 3,000 rpm 39.6 : 1 392.4 lb/s 808° F
SGT-A65 DLE 59.6 MW(e) 60 Hz 43.2% 7,895 Btu/kWh 3,600 rpm 36.6 : 1 363.8 lb/s 829° F
SGT-A65 DLE with ISI 64.9 MW(e) 60 Hz 43.3% 7,877 Btu/kWh 3,600 rpm 38.0 : 1 377.0 lb/s 819° F
SGT-A65 WLE with ISI 67.4 MW(e) 50 Hz 41.3% 8,269 Btu/kWh 3,000 rpm 39.9 : 1 392.4 lb/s 808° F
SGT-A65 WLE with ISI 70.8 MW(e) 60 Hz 41.4% 8,242 Btu/kWh 3,600 rpm 39.3 : 1 388.0 lb/s 837° F
SGT-A45 50 Hz (at 15 °C ambient) 41.0 MW(e) 50/60 Hz 39.0% 3,000/3,600 rpm 27.7 : 1 279.9 lb/s 891° F
SGT-A45 50 Hz (at 30 °C ambient) 39.3 MW(e) 50/60 Hz 38.4% 3,000/3,600 rpm 26.7 : 1 264.5 lb/s 934° F
SGT-A45 60 Hz (at 15 °C ambient) 44.0 MW(e) 50/60 Hz 40.4% 3,000/3,600 rpm 27.9 : 1 277.7 lb/s 901° F
SGT-A45 60 Hz (at 30 °C ambient) 39.6 MW(e) 50/60 Hz 39.5% 3,000/3,600 rpm 25.8 : 1 255.7 lb/s 928° F
SGT-A35 (GT30 38 MW) 50 Hz 36.6 MW(e) 50 Hz 38.7% 8,912 Btu/kWh 3,000 rpm 25.4 : 1 244.7 lb/s 912 °F
SGT-A35 (GT30 34 MW) 50 Hz 32.2 MW(e) 50 Hz 37.5% 9,109 Btu/kWh 3,000 rpm 22.9 : 1 220.0 lb/s 937 °F
SGT-A35 (GT30 34 MW) DLE 50 Hz 31.9 MW(e) 50 Hz 37.3% 9,140 Btu/kWh 3,000 rpm 22.6 : 1 218.6 lb/s 939° F
SGT-A35 (GT30 38 MW) 60 Hz 37.4 MW(e) 60 Hz 39.7% 8,600 Btu/kWh 3,600 rpm 25.0 : 1 240.5 lb/s 909 °F
SGT-A35 (GT30 34 MW) 60 Hz 33.2 MW(e) 60 Hz 38.5% 8,873 Btu/kWh 3,600 rpm 22.7 : 1 218.0 lb/s 934° F
SGT-A35 (GT30 34 MW) DLE 60 Hz 32.5 MW(e) 60 Hz 38.3% 8,906 Btu/kWh 3,600 rpm 22.3 : 1 215.8 lb/s 932° F
SGT-A35 (GT61) DLE 32.1 MW(e) 50/60 Hz 39.3% 8,681 Btu/kWh 4,850 rpm 21.6 : 1 207.0 lb/s 950° F
SGT-A35 (GT62) DLE 29.9 MW(e) 50/60 Hz 37.5% 9,387 Btu/kWh 4,800 rpm 20.6 : 1 201.0 lb/s 934° F
SGT-A35 (G62) DLE 27.2 MW(e) 50/60 Hz 36.4% 9,089 Btu/kWh 4,800 rpm 21.7 : 1 209.0 lb/s 933° F
SGT-A05 (KB7HE) 5.8 MW(e) 50/60 Hz 33.2% 10,281 Btu/kWh 14,600 rpm 14.0 : 1 47.1 lb/s 972° F
SGT-A05 (KB7S) 5.4 MW(e) 50/60 Hz 32.3% 10,570 Btu/kWh 14,600 rpm 13.9 : 1 47.0 lb/s 921° F
SGT-A05 (KB5S) 4.0 MW(e) 50/60 Hz 29.7% 11,504 Btu/kWh 14,200 rpm 10.3 : 1 34.0 lb/s 1,040° F

65
For more information, please contact
our Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E–mail: support.energy@siemens.com

Article No. PGDG-B10006-05-4A00


Dispo 05400 BR 04182.0

Subject to changes and errors. The information given in this


document only contains general descriptions and/or performance
features which may not always specifically reflect those
described, or which may undergo modification in the course of
further development of the products. The requested performance
features are binding only when they are expressly agreed upon in
the concluded contract.

TRENT and RB211 are registered trademarks of and used under


license from Rolls-Royce plc. 501, Avon, Trent and RB211 are
trademarks of and used under license of Rolls-Royce plc.
I