We power the world with

innovative gas turbines


Siemens gas turbine portfolio

This PDF offers an advanced interactive experience. For best view, please
use Acrobat Reader X or higher to explore the interactive elements.

siemens.com/gasturbines
Gas turbines
from 4 to 425 MW

The Siemens gas turbine range has


been designed and tailored to help
meet our ­customers‘ c­ hallenges in a
dynamic market environment.
Our models range from 4 to 425 MW,
fulfilling the requirements of a wide
spectrum of applications in terms of
efficiency, ­reliability, flexi­bility, and
environmental compa­­ti­bility.
The products offer low lifecycle costs
and an excellent return on investment.

Click for overview

Introduction
Heavy-duty gas turbines
Industrial gas turbines
Aeroderivative gas turbines
Applications SGT-100 packages for power generation

Gas turbine overview References


Siemens gas turbines overview
For more information, please click on a product name [Power generation in MW(e) / mechanical drive in MW]

SGT6-2000E [117 MW]


SGT-A30 RB and
Heavy-duty
gas turbines SGT-A35 RB SGT6-5000F [250 MW] 60 Hz
(Industrial RB211) [27 to 33 / 28 to 34 MW] SGT6-8000H [310 MW]

Industrial SGT-A05 AE [4 to 7 MW] SGT-700 [33 / 34 MW] SGT5-2000E [187 MW]


gas turbines (Industrial 501-K)
SGT-750 [40 / 41 MW] SGT5-4000F [329 MW] 50 Hz
SGT-100 [5 / 6 MW] SGT-800 [48 to 54 MW] SGT5-8000H [425 MW]

SGT-300 [8 / 8 to 9 MW]
SGT-A65 TR [53 to 66 / 54 to 62 MW]
Aeroderivative
gas turbines
SGT-400 [13 to 14 / 13 to 15 MW] (Industrial Trent 60)
SGT-600 [24 / 25 MW]

50 Hz or 60 Hz

Gas turbines in the range of

Gas turbines in the range of 100 – 425 MW


Gas turbines in the range of
15 – 100 MW
0 – 15 MW
Introduction General note:
References
All simple cycle and mechanical drive performance data in this document are gross values at ISO ambient conditions.
All combined cycle performance data in this document are net values at ISO ambient conditions, assuming 50 mbar condenser pressure.
The SGT5-8000H offers outstanding performance
and high flexibility. With a gross power output of
425 MW, it is one of the most powerful gas turbines
worldwide.
The turbine is the core component of highly efficient
­gas-fired power plants, designed for 630 MW at
61% efficiency in combined cycle operation.
With more than 350,000 fired hours, the
SGT-8000H series provides mature technology
with verified reliability and availability.

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

Technical Key
data sheet features Düsseldorf Lausward, Germany

SGT5-8000H Power output: 425 MW


Heavy-duty gas turbine

Power generation
The SGT5-8000H achieves a world-class efficiency of Frequency 50 Hz
61% in combined cycle operations Gross efficiency >40%
Exhaust temperature 640° C (1,184° F)

Introduction Gas turbine overview References


The SGT6-8000H offers outstanding performance
and high flexibility. The air-cooled turbine with a
gross power output of 310 MW is designed for
simple combined cycle integration and short start-
up times.
The turbine is the core component of highly efficient
gas-fired power plants, designed for 460 MW at
61% efficiency in combined cycle operation.
With more than 350,000 fired hours, the
SGT-8000H series provides mature technology
with verified reliability and availability.

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

Technical Key
data sheet features Dangjin 3, South Korea

SGT6-8000H Power output: 310 MW


Heavy-duty gas turbine

Power generation
The SGT6-8000H achieves a world-class efficiency of Frequency 60 Hz
61% in combined cycle operations Gross efficiency >40%
Exhaust temperature 645° C (1,193° F)

Introduction Gas turbine overview References


The proven SGT5-4000F gas turbine has a robust
design with internal cooling air passages for
trusted long-term operation and fast start-up
capability. The advanced annular combustion
chamber with individually replaceable heat shields
allows for easy and fast walk-in maintenance.
Hydraulic Clearance Optimization (HCO) reduces
clearance losses to increase the gas turbine effi-
ciency and minimize degradation at start-up and
shut down.
Today, around 350 turbines have been sold. The
installed fleet has accumulated an impressive fleet
experience of over 13 million equivalent operating
hours, and a fleet reliability of more than 99%.

„„ Proven design, large fleet experience


„„ Easy maintenance, high availability
„„ High operational flexibility

Technical Key
data sheet features Al Taweelah, United Arab Emirates

SGT5-4000F Power output: 329 MW


Heavy-duty gas turbine

Power generation
The SGT5-4000F is a well-proven 50 Hz gas turbine Frequency 50 Hz
with an outstanding reliability and availability Gross efficiency 40.7%
Exhaust temperature 600° C (1,112° F)

Introduction Gas turbine overview References


The SGT6-5000F gas turbine offers economical
power generation with fast start-up for peak,
intermediate, or base load duty. It achieves peak
values for reliability and continuous operation
with highest performance values in its class.
Today, more than 380 turbines have been sold.
The installed fleet has accumulated more than 13
million equivalent operating hours, with a fleet
reliability of over 99%.

„„ Highest power output for 60 Hz F-class


„„ Fast start-up and load changing capabilities
„„ Low emissions with an NOX emission of
≤9 ppmvd on gas and ≤25 ppmvd on oil

Technical Key
data sheet features La Caridad, Sonora, Mexico

SGT6-5000F Power output: 250 MW


Heavy-duty gas turbine

Power generation
The SGT6-5000F offers world-class reliability and best- Frequency 60 Hz
in-class emission values Gross efficiency 39.3%
Exhaust temperature 598° C (1,108° F)

Introduction Gas turbine overview References


The SGT5-2000E gas turbine is a proven, robust
engine for the 50 Hz market which is used in simple
cycle or combined cycle processes with or without
combined heat and power. It is suitable for all load
ranges, including peak load.
The SGT5-2000E offers outstanding fuel flexibility.
It can be fired with low calorific gases or gases contain-
ing CO2, H2S and N2, as well as with crude oil and other
liquid fuels with high viscosity. It provides low NOX
emissions, even in the part-load range.
Today, around 300 turbines have been sold, and
additionally, more than 200 units under license. Our
installed fleet has accumulated over 17 million
equivalent operating hours. The SGT-2000E series
fleet´s overall best-in-class r­ eliability exceeds 99.5%.

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Technical Key
data sheet features Az-Zour, Kuwait

SGT5-2000E Power output: 187 MW


Heavy-duty gas turbine

Power generation
Best-in-class reliable technology; robust and Frequency 50 Hz
flexible performance Gross efficiency 36.2%
Exhaust temperature 536° C (997° F)

Introduction Gas turbine overview References


The SGT6-2000E gas turbine is a proven, robust
engine for the 60 Hz market which is used in simple
cycle or combined cycle processes with or without
combined heat and power supply. It is suitable for all
load ranges, including peak load.
The SGT6-2000E offers outstanding fuel flexibility.
It can be fired with low calorific gases or gases contain-
ing CO2, H2S and N2, as well as with crude oil and other
liquid fuels with high viscosity. It provides low NOX
emissions, even in the part-load range.
Today, more than 100 turbines have been sold, result-
ing in a fleet experience of nearly 7 million equivalent
operating hours. The SGT-2000E series fleet´s over-
all best-in-class ­reliability constantly exceeds 99.5%.

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Technical Key Charles D. Lamb Energy Center,


data sheet features Oklahoma, USA

SGT6-2000E Power output: 117 MW


Heavy-duty gas turbine

Power generation
Best-in-class reliable technology; robust and Frequency 60 Hz
flexible performance Gross efficiency 35.2%
Exhaust temperature 532° C (990° F)

Introduction Gas turbine overview References


The SGT-800 industrial gas turbine offers broad
flexibility in fuels, operating conditions, maintenance
concepts, package solutions, and ratings.
The excellent efficiency and steam-raising capability
make it outstanding in cogeneration and combined
cycle installations. The SGT-800-based power plant,
designed for flexible operation, is perfectly suited as
grid support.
The SGT-800 combines a simple, robust design, for
high reliability and easy maintenance, with high
efficiency and low emissions.
With more than 300 units sold and over 4 million
equivalent operating hours, the SGT-800 is an excellent
choice for for industrial or oil and gas applications.

„„ Proven reliability
„„ Flexible solutions
„„ Excellent performance

Technical
data sheet
SGT-800 packages at the Amata B.Grimm Power Plant, Amata

SGT-800 Power generation: 47.5 – 54.0 MW(e)


Industrial gas turbine

Power generation SCC-800 2x1 combined cycle power plant


SGT-800 core engine is available in three ratings Frequency 50/60 Hz Net plant output 135.4 – 153.7 MW(e)
with standard options for hot and cold climates Gross efficiency 37.7 – 39.1% Net plant efficiency 54.7 – 56.7%
Exhaust temperature 541 – 563° C (1,007 – 1,045° F)
Exhaust mass flow 132.8 – 135.5 kg/s

Introduction Gas turbine overview References


With maximized uptime, top-class performance,
and a low environmental footprint offering the
customer high lifetime profitability, the SGT-750
industrial gas turbine is a perfect choice for the oil
and gas industry as well as industrial power
generation.
The modular and flexible engine enables onshore or
offshore applications, mechanical drive or heat and
power. It combines a robust, reliable design with
high efficiency and low emissions.
The SGT-750 has a track record of successful per-
formance after years in operation and verified results
in various applications. Units are sold for use in both
power generation and compressor applications such
as pipelines and liquefied natural gas (LNG).

„„ Maximized uptime
„„ High efficiency
„„ Low emissions

Technical
data sheet SGT-750 combined heat and power plant in Altamira, Mexico

SGT-750 Power generation: 39.8 MW(e)


Industrial gas turbine Mechanical drive: 41.0 MW

Power generation Mechanical drive applications


SGT-750 core engine with a free high-speed Frequency 50/60 Hz Efficiency 41.6%
power turbine Gross efficiency 40.3% Exhaust temperature 468° C (875° F)
Exhaust temperature 468° C (875° F) Exhaust mass flow 115.4 kg/s
Exhaust mass flow 115.4 kg/s

Introduction Gas turbine overview References


Thanks to its wide fuel range capability and design
features, the SGT-700 is a perfect choice for several
onshore applications: Industrial power generation,
oil and gas power generation, and mechanical drive
applications.
It performs well in combined cycle plants, and com-
bined heat and power plants.
The SGT-700 gas turbine is an evolution of the proven
SGT-600 and is specifically designed for higher power
output. It offers easy on-site or off-site maintenance,
and operates with a wide range of gaseous and liquid
fuels on Dry Low Emission (DLE).
About 80 units have been sold with 1.7 million
equivalent operating hours and more than 90,000
EOHs for the fleet-leading gas turbine.

„„ Robust, reliable design


„„ High fuel flexibility
„„ Low emissions

Technical
data sheet Three SGT-700 packages for mechanical drive

SGT-700 Power generation: 32.8 MW(e)


Industrial gas turbine Mechanical drive: 33.7 MW

Power generation Mechanical drive applications


Maintainable, reliable, and robust twin-shaft Frequency 50/60 Hz Efficiency 38.2%
design for mechanical drive and power generation Gross efficiency 37.2% Exhaust temperature 533° C (991° F)
Exhaust temperature 533° C (991° F) Exhaust mass flow 95.0 kg/s
Exhaust mass flow 95.0 kg/s

Introduction Gas turbine overview References


High reliability and availability in combination with
good fuel flexibility and third-generation DLE makes
the SGT-600 a perfect choice for several onshore
applications: Industrial power generation, oil and gas
power generation, and mechanical drive applications.
Within the IPG applications, the turbine performs well
in combined heat and power plants, and
combined cycle plants.
The industrial gas turbine combines a robust, reliable
design with high fuel flexibility, and low emissions.
More than 330 units have been sold with over 9 million
equivalent operating hours, and 185,000 equivalent
operating hours for the fleet-leading gas turbine.

„„ Robust, reliable design


„„ High fuel flexibility
„„ Low emissions

Technical
data sheet SGT-600 installation for both mechanical drive and power generation

SGT-600 Power generation: 24.5 MW(e)


Industrial gas turbine Mechanical drive: 25.2 MW

Power generation Mechanical drive applications


Maintainable, reliable, and robust twin-shaft Frequency 50/60 Hz Efficiency 34.6%
design for mechanical drive and power generation Gross efficiency 33.6% Exhaust temperature 543° C (1,009° F)
Exhaust temperature 543° C (1,009° F) Exhaust mass flow 81.3 kg/s
Exhaust mass flow 81.3 kg/s

Introduction Gas turbine overview References


The SGT-400 is a twin-shaft gas turbine available in
two d
­ ifferent power ratings for both power generation
and mechanical drive applications.
The twin-shaft arrangement allows for commonality
of parts in mixed-duty installations.
The gas turbine offers the highest efficiency in its
power class, incorporating the latest aerodynamic
and combustion technologies.
With over 15 years of operating experience, the
SGT-400 is proven in both offshore and onshore
applications. Over 350 units have been sold with more
than 3.2 million hours operating experience. The
fleet leader has accumulated more than 200,000
equivalent operating hours.

„„ Latest aerodynamic and combustion technology


„„ Suitable for all climates, onshore and offshore
„„ High power-to-weight ratio

Technical
data sheet The SGT-400 is available as a factory-assembled package

SGT-400 Power generation: 12.9 / 14.3 MW(e)


Industrial gas turbine Mechanical drive: 13.4 / 14.9 MW

Power generation Mechanical drive applications


Twin-shaft design for both power generation and Frequency 50/60 Hz Efficiency 36.2 – 36.8%
mechanical drive applications Gross efficiency 34.8 – 35.4% Exhaust temperature 540 – 555° C (1,004 – 1,031° F)
Exhaust temperature 540 – 555° C (1,004 – 1,031° F) Exhaust mass flow 39.4 kg/s – 44.0 kg/s
Exhaust mass flow 39.4 – 44.0 kg/s

Introduction Gas turbine overview References


The SGT-300 industrial gas turbine has a rugged
industrial design that enables high efficiency,
reliability, and excellent emissions performance
in a broad spectrum of applications for both power
generation and mechanical drive.
The gas turbine is a proven unit for all electrical
power generation and cogeneration applications.
It operates on a wide range of gaseous and liquid
fuels. The compact arrangement, on-site or off-site
maintainability, and inherent reliability of the SGT-300
make it an ideal gas turbine for the demanding oil and
gas industry.
Over 150 units have been sold, with more than
5.6 million equivalent operating hours.

„„ Low maintenance requirements


„„ Low emissions
„„ Single-shaft version for power generation,
twin-shaft version for mechancial drive applications

Technical
data sheet The SGT-300 twin-shaft version is used for mechanical drive

SGT-300 Power generation: 7.9 MW(e)


Industrial gas turbine Mechanical drive: 8.4 / 9.2 MW

Power generation Mechanical drive applications


Robust, reliable, maintainable single-shaft version Frequency 50/60 Hz Efficiency 35.1 – 35.6%
for power generation applications Gross efficiency 30.6% Exhaust temperature 491 – 512° C (916 – 954° F)
Exhaust temperature 542° C (1,008° F) Exhaust mass flow 29.7 – 30.5 kg/s
Exhaust mass flow 30.2 kg/s

Introduction Gas turbine overview References


The SGT-100 industrial gas turbine is a proven unit for
all electrical power generation and mechanical drive
applications. The compact arrangement, on-site or
off-site maintainability, and inherent reliability makes
it an ideal gas turbine for the demanding oil and gas
industry.
The gas turbine has a rugged industrial design that
enables high efficiency and excellent emissions
performance on a wide range of gaseous and liquid
fuels.
More than 410 units have been sold with more than
25 million operating hours. The lead package has
over 180,000 equivalent hours of operation.

„„ Robust and reliable product


„„ Wide range of gaseous and liquid fuels
„„ Single-shaft version for power generation or
twin-shaft version for mechanical drive applications

Technical
data sheet The SGT-100 combines advanced technology with robust construction

SGT-100 Power generation: 5.05 / 5.4 MW(e)


Industrial gas turbine Mechanical drive: 5.7 MW

Power generation Mechanical drive applications


Robust, reliable, maintainable single-shaft design Frequency 50/60 Hz Efficiency 32.9%
for power generation applications Gross efficiency 30.2 – 31.0% Exhaust temperature 543° C (1,009° F)
Exhaust temperature 531 – 545° C (988 –1,013° F) Exhaust mass flow 19.7 kg/s
Exhaust mass flow 19.5 – 20.6 kg/s

Introduction Gas turbine overview References


Designed for industrial use in power generation and
mechanical drive applications, the SGT-A65 TR has
established a new benchmark for power output, fuel
economy, and cost savings.
The gas turbine is highly flexible, offering high power
and efficiency with minimal drop-off at part-load and
reduced speed conditions. It is available with Wet Low
Emission (WLE) and DLE combustion systems.
The SGT-A65 TR is proven in many different envi-
ronments and applications.
More than 100 units have been sold with more than
1.1 million equivalent operating hours. The fleet
leader has accumulated more than 110,000 EOHs.

„„ Most powerful, pure aeroderivative gas turbine


in its class
„„ Flexible with high cyclic life and fast starts
„„ Modular package design to allow for quick
installation and maintenance in the field

Technical
data sheet
SGT-A65 TR units for power generation

SGT-A65 TR Power generation: 53.1 – 66.0 MW(e)


Mechanical drive: 54.2 – 61.8 MW
(Industrial Trent 60)
Aeroderivative gas turbine

Power generation Mechanical drive applications


The SGT-A65 TR can cold-start to full power in Frequency 50/60 Hz Efficiency 41.9 – 43.6%
under 10 minutes and additionally has high cyclic Gross efficiency 41.1 – 43.4% Exhaust temperature 428 – 431 °C (802 – 807 °F)
life Exhaust temperature 416 – 433 °C (781 – 811 °F) Exhaust mass flow 154.4 – 164.2 kg/s
Exhaust mass flow 155 – 180 kg/s

Introduction Gas turbine overview References


With class-leading reliability and availability, the
SGT-A30 RB and SGT-A35 RB are proven, dependable
choices in power generation and mechanical drive
applications. They are qualified to meet the stringent
standards of the oil and gas industry in both onshore
and offshore service.
The aeroderivative gas generator is highly tolerant
of transient excursions and challenging mission
cycles, and can be easily exchanged at site, reducing
maintenance downtime and cost. Both conventional
and DLE combustion systems are available, including
dual fuel capability.
In a 40-year evolution, the SGT-A30 RB and SGT-A35 RB
have accumulated over 36 million equivalent oper-
ating hours, with over 750 units sold.

„„ Proven track record in the oil and gas industry


„„ Several variants to meet different power needs
„„ Lightweight, compact, modular package design
to maximize power density

Technical
data sheet
Two SGT-A35 RB (Industrial RB211-GT30) packages on an FPSO vessel

SGT-A30 RB / SGT-A35 RB Power generation: 27.2 – 33.2 MW(e)


Mechanical drive: 27.9 – 33.8 MW
(Industrial RB211)
Aeroderivative gas turbine

Power generation Mechanical drive applications


The SGT-A35 RB is a two-spool gas generator aerody- Frequency 50/60 Hz Efficiency 37.3 – 40.4%
namically coupled to a free power turbine Gross efficiency 36.4 – 39.3% Exhaust temperature 500 – 509° C (932 – 949° F)
Exhaust temperature 501 – 509° C (934 – 949° F) Exhaust mass flow 91.0 – 99.3 kg/s
Exhaust mass flow 91.0 – 99.8 kg/s

Introduction Gas turbine overview References


Based on proven aeroderivative design, the SGT-A05 AE
delivers high efficiency and outstanding reliability for
power generation applications like cogeneration and
emergency power. The gas turbine offers rugged,
easy-to-maintain performance due to features such
as on-engine mounted auxiliary equipment.
The gas turbine engine is designed to operate on a
wide variety of fuels. The fuel system operations
include dual fuel, steam, and water injection. DLE
technology is also available.
The SGT-A05 AE has accumulated over 110 million
hours of operation with more than 500 customers
in 53 countries.

„„ More than 1,600 gas turbines supplied


„„ Full power available within 60 seconds
„„ High electrical and cycle efficiency

Technical
data sheet Power station at Mitchelstown, Ireland

SGT-A05 AE Power generation: 4.0 – 6.6 MW(e)


(Industrial 501-K)
Aeroderivative gas turbine

Power generation
The SGT-A05 AE has black start and hot start capa- Frequency 50/60 Hz
bility. Full power is available within 60 seconds Gross efficiency 29.7 – 41.2%
Exhaust temperature 494 – 560° C (921 – 1,040° F)
Exhaust mass flow 15.4 – 21.3 kg/s

Introduction Gas turbine overview References


References

Siemens gas turbines are operating in


more than 60 countries.

We provide proven technology with


over 6,750 installed heavy-duty, industrial
and aeroderivative gas turbines.

Move your mouse over one of the


reference
Siemens gashighlights
turbinestoare
seeoperating
details, and
in
use
morethe buttons
than below to show references
60 countries.
for each gas turbine.
We provide proven technology with
Reference highlight over 6,900 installed heavy-duty,
for power generation industrial and aeroderivative gas
turbines.
Reference highlight
for mechanical drive

More installations

SGT5-8000H SGT6-5000F SGT-800 SGT-600 SGT-100 SGT-A65 TR (Industrial Trent 60)


Show all or choose SGT6-8000H SGT5-2000E SGT-750 SGT-400 SGT-A30 RB / SGT-A35 RB (Industrial RB211)
highlights your turbine:
SGT5-4000F SGT6-2000E SGT-700 SGT-300 SGT-A05 AE (Industrial 501-K)

Introduction Gas turbine overview References


Performance data overview: Power generation
Power generation (metric units) Power generation (imperial units) Mechanical drive (metric units) Mechanical drive (imperial units)

Power output Frequency Gross Heat rate Turbine speed Pressure Exhaust Exhaust
efficiency ratio mass flow temperature
SGT5-8000H 425 MW 50 Hz > 40% < 9,000 kJ/kWh 3,000 rpm 20.0 : 1 880.0 kg/s 640° C
SGT6-8000H 310 MW 60 Hz > 40% < 9,000 kJ/kWh 3,600 rpm 20.0 : 1 650.0 kg/s 645° C
SGT5-4000F 329 MW 50 Hz 40.7% 8,846 kJ/kWh 3,000 rpm 20.0 : 1 725.0 kg/s 600° C
SGT6-5000F 250 MW 60 Hz 39.3% 9,160 kJ/kWh 3,600 rpm 18.9 : 1 588.0 kg/s 598° C
SGT5-2000E 187 MW 50 Hz 36.2% 9,945 kJ/kWh 3,000 rpm 12.8 : 1 558.0 kg/s 536° C
SGT6-2000E 117 MW 60 Hz 35.2% 10,239 kJ/kWh 3,600 rpm 12.0 : 1 368.0 kg/s 532° C
SGT-800 (54.0 MW) 54.0 MW(e) 50/60 Hz 39.1% 9,206 kJ/kWh 6,608 rpm 21.4 : 1 135.5 kg/s 563° C
SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 9,389 kJ/kWh 6,608 rpm 21.0 : 1 134.2 kg/s 553° C
SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,547 kJ/kWh 6,608 rpm 20.1 : 1 132.8 kg/s 541° C
SGT-750 39.8 MW(e) 50/60 Hz 40.3% 8,922 kJ/kWh 6,100 rpm 24.3 : 1 115.4 kg/s 468° C
SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,675 kJ/kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C
SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,720 kJ/kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C
SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 10,178 kJ/kWh 9,500 rpm 18.9 : 1 44.0 kg/s 540° C
SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 10,355 kJ/kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C
SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,773 kJ/kWh 14,010 rpm 13.7 : 1 30.2 kg/s 542° C
SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,612 kJ/kWh 17,384 rpm 15.6 : 1 20.6 kg/s 531° C
SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,913 kJ/kWh 17,384 rpm 14.0 : 1 19.5 kg/s 545° C
SGT-A65 TR DLE 53.1 MW(e) 50 Hz 42.0% 8,488 kJ/kWh 3,000 rpm 34.5 : 1 155.0 kg/s 433° C
SGT-A65 TR DLE with ISI 63.5 MW(e) 50 Hz 43.2% 8,322 kJ/kWh 3,000 rpm 37.9 : 1 177.0 kg/s 417° C
SGT-A65 TR DLE 54.0 MW(e) 60 Hz 42.5% 8,465 kJ/kWh 3,600 rpm 33.6 : 1 158.0 kg/s 431° C
SGT-A65 TR DLE with ISI 61.8 MW(e) 60 Hz 43.4% 8,300 kJ/kWh 3,600 rpm 36.2 : 1 168.0 kg/s 421° C
SGT-A65 TR WLE with ISI 66.0 MW(e) 50 Hz 41.5% 8,669 kJ/kWh 3,000 rpm 39.0 : 1 180.0 kg/s 416° C
SGT-A65 TR WLE with ISI 65.7 MW(e) 60 Hz 41.1% 8,760 kJ/kWh 3,600 rpm 38.0 : 1 172.0 kg/s 426° C
SGT-A35 RB 60 Hz 33.2 MW(e) 60 Hz 38.5% 9,362 kJ/kWh 3,600 rpm 22.7 : 1 98.9 kg/s 501° C
SGT-A35 RB 50 Hz 32.2 MW(e) 50 Hz 37.5% 9,611 kJ/kWh 3,000 rpm 22.9 : 1 99.8 kg/s 503° C
SGT-A30 RB (30 MW) DLE 29.9 MW(e) 50/60 Hz 37.5% 9,589 kJ/kWh 4,800 rpm 21.7 : 1 95.0 kg/s 503° C
SGT-A30 RB (27 MW) DLE 27.2 MW(e) 50/60 Hz 36.4% 9,904 kJ/kWh 4,800 rpm 20.6 : 1 91.0 kg/s 501° C
SGT-A30 RB (32 MW) DLE 32.1 MW(e) 50/60 Hz 39.3% 9,159 kJ/kWh 4,850 rpm 21.6 : 1 94.0 kg/s 510° C
SGT-A05 AE (6.6 MW) w/ case steam 6.6 MW(e) 50/60 Hz 41.2% 8,741 kJ/kWh 14,600 rpm 10.3 : 1 18.4 kg/s 530° C
SGT-A05 AE (5.4 MW) 5.4 MW(e) 50/60 Hz 32.3% 11,152 kJ/kWh 14,600 rpm 13.9 : 1 21.3 kg/s 494° C
SGT-A05 AE (4.0 MW) 4.0 MW(e) 50/60 Hz 29.7% 12,137 kJ/kWh 14,200 rpm 10.3 : 1 15.4 kg/s 560° C

Introduction Gas turbine overview References


For more information, please contact
our Siemens Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E–mail: support.energy@siemens.com
www.siemens.com/gasturbines
Article-No. PGDG-B10006-04-4A00
Dispo 34806 BR 01172.4

Subject to changes and errors. The information given in this document only contains general
descriptions and/or performance features which may not always specifically reflect those
described, or which may undergo modification in the course of further development of the
products. The requested performance features are binding only when they are expressly
agreed upon in the concluded contract.
TRENT and RB211 are registered trademarks of and used under license from Rolls-Royce plc.
501, Avon, Trent and RB211 are trademarks of and used under license of Rolls-Royce plc.