DC SERVOAMPLIFIERS
RTS
SERVOAMPLIFiER
The compact RTS is a PWM servo-amplifier for four-quadrants DC brush type servomotor operation.
The power range of the RTS is up 6500 W.
This user friendly servo-amplifier integrates the power supply, the resistive braking circuit and low
voltage DC supply into one small package.
FUNCTIONS
RTS SPECIFICATIONS 3/10-40M 10/20-60 12/24-..B 12/24-130T 20/40-130T 16/32-190T 40/80-190T 40/80-..B
(Based on 40°C ambient)
Single-phase 1 or 3 phases Battery three-phase three-phase three-phase three-phase three-phase
Input voltage range Vac 20 - 35 30 - 53 24 – 48Vcc 60 - 110 60 - 110 80 - 148 85 - 162 36 - 72
Nominal input voltage Vac 32 ± 10% 48 ± 10% - 100 ± 10% 100 ± 10% 135 ± 10% 150 -
Nominal DC output voltage V= 40 60 U Battery 130 130 190 200 U Battery
–2V –2V
Nominal output current A 3 10 12 12 20 16 40 40
Peak current limit (2 sec clamp) A 10 20 24 24 40 32 80 80
Minimum inductance required mH 1 0.4 0.4 0.8 0.4 0.8 0.4 0.2
TECHNICAL SPECIFICATIONS
Power reduction with altitude Above 1000 m, 10% fall in useful power per 1000 m up to maximum
4000 m
Operating temperature Normal use: 0 to + 40°C
Above 40°C, 35% fall in useful power per 10°C up to maximum 60°C
Storage temperature -30°C to +85°C
Chopping frequency 17 kHz current
Technology Photocoupler controlled MOS transistors.
Bandwidth in current Up to 1500 Hz
Bandwidth in speed Up to 150 Hz at 90° phase shift
Tachogenerator maximum voltage 100 V at input
Speed range 1:10 000 with tachogenerator
1:10 with armature reaction (U - RI)
Static precision of speed for load From Nmax to Nmax/100 +/- 0.5%
variation of 0 at In and for servo amplifier
From Nmax/100 to Nmax/1000 +/-1.5%
rated voltage
From Nmax/1000 to Nmax/10 000 +/-10%
U-RI control, from Nmax to Nmax/10 +/-20%
Current control – Precision - Linearity +/-2% of rated current at 25°C
+/-1% of rated current at 25°C
Electrical protection - Galvanic insulation of power bridge
- Magnetic current sensor
- Power outputs protected against phase-to-phase and phase to-
ground short-circuits
Connections Plug-in terminal blocks on front panel
Protection IP00, IP20 for shrouded versions
TYPICAL EXAMPLES
Combination Thermally permanent operation Pulse Motor
Slow rotation Maximum limits limits inertia
-5 2
Servomotor Servoamplifier Crl (N.m) Cmp (N.m) Nmp (rpm) Pmp (W) Ci (N.m) Nr (rpm) 10 kg.m
RX 120 L RTS 3/10-40M 0.28 0.28 2600 77 0.63 1450 5
RX 120 L RTS 10/20-60 (x) 0.28 0.275 4360 126 0.63 3200 5
RX 130 H RTS 10/20-60 (x) 0.4 0.39 4185 169 0.90 3200 6.8
RX 320 E RTS 10/20-60 (x) 1 1 3420 358 2.43 2300 50
RX 330 C RTS 10/20-60 (x) 1.54 1.4 2900 425 3.2 2000 72
RX 520 K RTS 12/24-130 T 2.7 2.60 3030 825 5.8 2200 128
RX 530 F RTS 12/24-130 T 3.7 2.975 3050 950 7.8 2100 174
RX 620 J RTS 12/24-130 T 5 4.5 2330 1086 11 1900 350
RX 630 E RTS 20/40-130 T 7.6 7 2915 2070 16.8 1700 500
Pmp : Maximum useful thermally permanent power corresponding to Tmp and Nmp.
Speed of rotation and torque may be restricted to lower values on request by RTS settings.
Nr Nmp Ns
O
Speed
PARVEX SAS
8 avenue du Lac - B.P. 249
F-21007 Dijon Cedex
Telephone + 33 (0)3 80 42 41 40 - Fax + 33 (0)3 80 42 41 23