67auto CT
67auto CT
67auto CT
Distributed intelligence –
Local control power Program overview
The control technology from Phoenix Controllers as per IEC 61131 19
Contact offers a wide range of networking
options with INTERBUS and PROFINET. All
controllers are suitable for centralized and Software 35
distributed use. Modular compact
controllers ensure that computing capacity Flow chart programming 59
is provided directly where it is needed.
This means that even fast control processes
using many local controllers on site can High-level language control 69
be implemented cost-effectively. With
INTERBUS and PROFINET as connections
nanoLine® controller range 79
to the I/O level and Ethernet, PROFINET or
INTERBUS for networking with higher-level
systems such as the control or operating Automation system of the 100 class 95
level, the PC WorX automation software
supports controller networking in a user-
friendly manner. Safety 101
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 17
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
18 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Controllers as per IEC 61131
Centralized or distributed
Program overview
The right controller for every
application: The product portfolio from Technical description 20
Phoenix Contact ranges from monitors
with integrated controllers, to modular Product overview 20
control solutions up to compact high-end
controllers. The devices are grouped into Embedded controllers
different performance classes.
Performance class 100 24
Within the framework of
modularization, the machine or system is Performance class 200 27
made up of tested function modules that
Performance class 300 28
are suitable for different production steps
such as filling, closing, labeling, grouping or Performance class 400 30
packing. Customer requirements can thus
be implemented quickly and cost-effectively. PC-based control systems
The control solution must now be adapted S-MAX 4xx CE PN multi-functional controller 32
to the new mechanical structure. The user
may require a different control capacity or
screen size (12" to 17") for each module.
A wide range of different controllers with
different control capacities is essential for
economic implementation of the
distributed approach.
Each of the controllers is uniformly
programmed and parameterized using the
PC Worx software. The connectivity of
controllers and the distributed approaches
in automation technology play a very
important role here. Thanks to the virtually
limitless communication options provided
by controllers, distributed automation
solutions are easy to implement.
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 19
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131 – Technical description
Inline controller – Compact and Remote Field Controller – S-MAX – combines high-performance
modular Communicative and high- PC platform, PLC, visualization, and
performance fieldbus master in the high-end class
The right controller for every
embedded application. An Inline controller Remote Field Controllers are high- S-MAX offers PC-based solutions when
transforms an Inline I/O station into a performance compact controllers. They are a controller is required to perform more
modular compact controller. A special suitable for the medium to high-end specialized high-end class functions,
feature of the Inline controller product application range in automation technology. e.g. visualization, in addition to its
range is the highly modular expandability of INTERBUS and Ethernet are used as traditional tasks.
the I/O level. With the Inline installation fieldbus interfaces. More often than not, The all-in-one S-MAX machine
system, Inline controllers can be used to Remote Field Controllers are used as controller belongs to the new controller
set up high-performance controllers. All centralized controllers because of their high generation with the highest level of
conceivable sensor and actuator interfaces, performance. As centralized controllers, performance.
from digital and analog inputs and outputs they often take care of the entire The 12", 15" and 17" devices of the
to function terminals for open and closed- communication with individual fieldbus S-MAX product range use the Pentium
loop control, are available. If you want to modules and the communication with other M-technology and can be easily integrated
integrate more distributed devices, an controllers and higher-level operating and into system concepts based on centralized
INTERBUS interface is available in addition control systems. or distributed controllers. The devices thus
to the Ethernet coupling. Inline controllers need very little configuration and also
cover the performance range from smaller provide a high level of transparency and
controllers, which are preferably used for comprehensive functionality at the same
distributed tasks, to medium-sized time.
applications as centralized control Communication with higher levels,
solutions. other distributed controllers and I/O
components is carried out using
international standards such as Ethernet
TCP/IP and PROFINET.
S-MAX 412 CE PN/M fulfills the
requirements of classification societies for
the maritime field. You can visit the Phoenix
Contact website for more information on
the latest approvals.
The S-MAX 400 CE PN series is a series
of devices without screens, but with
otherwise identical technical data.
20 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131 – Technical description
Management level
Concept I – Classical Concept II – Distributed Concept III – Full Ethernet
Ethernet
Controller level
MMS Control communication
RFC
RFC RFC
Switch
Ethernet
Ethernet
Switch
MCS
Rugged Line with fiber optics Inline Fieldline
Stand-Alone
Inline
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 21
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131 – Product overview
Description The 100 series performance class offers the best performance among The 200 series performance class rounds off the controller hardware
mini controllers at a low price. within the mini controller class with integrated special functions, tailored
to mechanical applications.
Last but not least, the seamless PC WORX programming environment
with its free assistant PC WORX EXPRESS, which has been especially These include integrated, quick counters and pulse width modulated
designed for controllers of the 100 series performance class, makes this outputs as well as a floating point unit for control applications.
class very attractive for small to medium-sized applications.
In addition to the integrated web and FTP server, controllers of the
100 series performance class provide all protocols and transmission
standards from IT technology without requiring expensive additional
modules.
Description The ILC 130 starter kit offers you a quick entry into the field of automation
and guides you when you use control technology from Phoenix for the
first time.
The ILC 130 starter kit available pre-assembled. All components
required for operation are available on a DIN rail. These components
include the smart ILC 130 ETH mini controller, an analog input module, a
power supply unit, a potentiometer and a switch panel for entering
operating states. A CD containing the demo version of the automation
software suite also contains the free PC WORX EXPRESS development
environment.
22 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131 – Product overview
300 400
The 300 series performance class offers considerably more The 400 series performance class offers maximum performance and
performance due to more powerful hardware. functionality.
In addition to the Ethernet functionality, controllers of this performance These high-end controllers make use of the centralized approach in their
class also offer PROFINET as a fieldbus. These controllers can be automation network. Controllers of the 400 series performance class are
PROFINET masters as well as PROFINET devices. the right choice even when high computing capacity is required for highly
dynamic control applications or when a high data throughput is required.
Processing speed –
The small difference
The processing speed of the controllers
from Phoenix Contact is specified in 10%
computing time per 1024 commands. This is
determined using a test program, which
comprises commands and data types similar
30%
to typical applications. The processing time
value is used for the relative classification of 20%
controllers into the various performance
classes.
20% 20%
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 23
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Performance class 100
uFxvl
Applied for: UL-EX LIS / CUL-EX LIS / NV
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Inline controllers, complete with accessories (connector and
labeling field)
ILC 130 ETH 2988803 1 ILC 150 ETH 2985330 1
User manual, for project planning and installation of INTERBUS,
with collection of data sheets
- German IBS SYS PRO INST UM 2743792 1 IBS SYS PRO INST UM 2743792 1
- English IBS SYS PRO INST UM E 2743802 1 IBS SYS PRO INST UM E 2743802 1
User manual, for configuring and installing the INTERBUS Inline
product range
- German IB IL SYS PRO UM 2745554 1 IB IL SYS PRO UM 2745554 1
- English IB IL SYS PRO UM E 2743048 1 IB IL SYS PRO UM E 2743048 1
Programming cable
PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1
Parameterization memory
- 256 MB
AX-OPC-SERVER, communication interface for OPC-capable
visualization with PC WORX-based controls
Automation software PC WORX ... (see software) PC WORX ... (see software)
Technical data
Interfaces
INTERBUS local bus (master) Inline data jumper Inline data jumper
Ethernet RJ45 female connector RJ45 female connector
Parameterization/operation/diagnostics RS-232-C, 6-pos. MINI-DIN female connector (PS/2), RS-232-C, 6-pos. MINI-DIN female connector (PS/2),
Ethernet 10/100 (RJ45) Ethernet 10/100 (RJ45)
INTERBUS master
Number of possible parameter channels Max. 8 Max. 16
Number of I/O nodes Max. 4096 Max. 4096
Number of supported devices Max. 63 Max. 128
Direct inputs/outputs
Number of inputs 8 8
Number of outputs 4 4
IEC-61131 runtime system
Programmable under PC WorX in IEC 61131 PC WorX in IEC 61131
Processing speed 1.7 ms (1 K instructions in mix, 90 µs for 1 K bit instructions) 1.5 ms (1 K instructions in mix, 90 µs for 1 K bit instructions)
Program memory 192 kByte (16 K instructions (IL)) 256 kByte (21 K instructions (IL))
Data memory 192 kByte 256 kByte
Retentive data memory 8 kByte (NVRAM) 8 kByte (NVRAM)
Number of data blocks (depending on data memory) (depending on data memory)
Number of timers, counters (depending on data memory) (depending on data memory)
Number of control tasks 8 8
Realtime clock Yes Yes
Power supply
Supply voltage 24 V DC 24 V DC
Range of supply voltages 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC
Typical current consumption 210 mA (no local bus device connected during idling, bus inactive) 210 mA (no local bus device connected during idling, bus inactive)
General data
Width 80 mm 80 mm
Height 119.8 mm 119.8 mm
Depth 71.5 mm 71.5 mm
Degree of protection IP20 IP20
Ambient temperature (operation) -25°C ... 60°C -25°C ... 60°C
24 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
ILC 155 ETH ILC 150 GSM/GPRS ILC 170 ETH 2TX
Inline controller with integrated Ethernet interface and Inline controller with integrated Ethernet interface, Inline connection Inline controller with two integrated Ethernet interfaces and one
Inline connection and GSM modem Inline connection
ILC 155 ETH 2988188 1 ILC 150 GSM/GPRS 2916545 1 ILC 170 ETH 2TX 2916532 1
IBS SYS PRO INST UM 2743792 1 IBS SYS PRO INST UM 2743792 1 IBS SYS PRO INST UM 2743792 1
IBS SYS PRO INST UM E 2743802 1 IBS SYS PRO INST UM E 2743802 1 IBS SYS PRO INST UM E 2743802 1
PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1
PC WORX ... (see software) PC WORX ... (see software) PC WORX ... (see software)
8 16 8
4 4 4
512 kByte (43 K instructions (IL)) 512 kByte (43 K instructions (IL)) 512 kByte (43 K instructions (IL))
512 kByte 512 kByte 512 kByte
48 kByte (NVRAM) 48 kByte (NVRAM) 48 kByte (NVRAM)
(depending on data memory) (depending on data memory) (depending on data memory)
(depending on data memory) (depending on data memory) (depending on data memory)
8 8 8
Yes Yes Yes
24 V DC 24 V DC 24 V DC
19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC
210 mA (no local bus device connected during idling, bus inactive) 210 mA (no local bus device connected during idling, bus inactive) 210 mA (no local bus device connected during idling, bus inactive)
80 mm 85 mm 80 mm
119.8 mm 119.8 mm 119.8 mm
71.5 mm 71.5 mm 71.5 mm
IP20 IP20 IP20
-25°C ... 60°C -25°C ... 60°C -25°C ... 60°C
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 25
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
ILC 130 starter kit – Your entry into
Phoenix Contact control technology
90 µs (bit data types), 1.7 ms (mixed data AX-OPC-SERVER, communication interface for OPC-capable
visualization with PC WORX-based controls
types)
AX OPC SERVER 2985945 1
– Program / data memory: 192 kB / 192 kB WebVisit, development software for web-based visualization WEBVISIT... (see software)
– Remanent data memory: 8 kB
Automation software PC WORX ... (see software)
Technical data
See ILC 130 ETH on page 24
26 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Performance class 200
uP
Applied for: UL-EX / CUL-EX
Pcs. /
Description Type Order No.
Pkt.
Inline controllers, complete with accessories (connector and
labeling field)
ILC 200 UNI-PAC 2862291 1
ILC 200 IB-PAC 2862288 1
User manual
- German ILC 200 UNI UM 2698630 1
ILC 200 IB UM 2729716 1
ILC 200 UNI UM E 2698643 1
- English ILC 200 IB UM E 2729729 1
User manual, for project planning and installation of INTERBUS,
with collection of data sheets
- German IBS SYS PRO INST UM 2743792 1
- English IBS SYS PRO INST UM E 2743802 1
User manual, for configuring and installing the INTERBUS Inline
product range
- German IB IL SYS PRO UM 2745554 1
- English IB IL SYS PRO UM E 2743048 1
Programming cable
PRG CAB MINI DIN 2730611 1
Connector set
ILC UNI-PLSET 2737083 1
ILC IB-PLSET 2729622 1
INTERBUS OPC server, data interface between distributed
INTERBUS and Ethernet networks and visualization systems
Direct inputs/outputs
Number of inputs 4
Description of the input Interrupt input, fast counter, Interrupt input, event counting,
pulse generator pulse generation
Number of outputs 2
IEC-61131 runtime system
Programmable under PC WorX in IEC 61131
Processing speed 1.3 ms (1 K bit instruction)
Program memory Typ. 380 kByte (32 K instructions (IL))
Data memory 330 kByte
Retentive data memory 8 kByte (NVRAM)
Number of data blocks (depending on data memory)
Number of timers, counters (depending on data memory)
Number of control tasks 8
Realtime clock Yes -
General data
Width 73 mm 109.8 mm
Height 140.5 mm
Depth 71.5 mm
Degree of protection IP20
Ambient temperature (operation) -25°C ... 55°C
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 27
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Performance class 300
U
Pcs. /
Description Type Order No.
Pkt.
Inline controllers, complete with accessories (connector and
labeling field) and PROFINET IO controllers
Power supply
Supply voltage 24 V DC ±5%
Range of supply voltages 20.4 V DC ... 30 V DC
Typical current consumption 250 mA (no local bus device connected during idling, bus inactive)
General data
Width 182 mm
Height 140.5 mm
Depth 71.5 mm
Degree of protection IP20
Ambient temperature (operation) -25°C ... 55°C
28 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
ILC 350 ... ILC 370 ... 2TX-IB... ILC 390 PN 2TX-IB
Inline controller with integrated Ethernet interface and Inline controller with integrated Ethernet interfaces, Inline controller with integrated Ethernet interfaces,
Inline connection INTERBUS slave interface and Inline connection INTERBUS slave interface, Inline connection and
PROFINET IO controller
u
Ex: N u u
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
ILC 350 PN 2876928 1 ILC 370 PN 2TX-IB 2876915 1 ILC 390 PN 2TX-IB 2985314 1
ILC 370 PN 2TX-IB/M 2985576 1
ILC 350 ETH 2737203 1 ILC 370 ETH 2TX-IB 2876999 1
ILC 350 ETH/M 2985819 1 ILC 370 ETH 2TX-IB/M 2985327 1
PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1
PC WORX ... (see software) PC WORX ... (see software) PC WORX ... (see software)
12 12 12
Eight fast inputs, interrupt input Eight fast inputs, interrupt input Eight fast inputs, interrupt input
4 4 4
16 16 16
Integrated (battery-backed) Integrated (battery-backed) Integrated (battery-backed)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 29
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Performance class 400
u
Pcs. /
Description Type Order No.
Pkt.
Remote field controller for Ethernet, with electrical isolation, IP20
degree of protection
- 1x10/100 Ethernet RFC 430 ETH-IB 2730190 1
- 1x10/100 Ethernet
- 3 x 10/100 Ethernet, PROFINET IO controller
INTERBUS master
Number of possible parameter channels Max. 126
Number of I/O nodes Max. 8192
Number of supported devices 512 (of which 254 are remote bus devices/bus segments)
Direct inputs/outputs
Number of inputs 5
Number of outputs 3
IEC-61131 runtime system
Processing speed 0.1 ms
Program memory Typ. 2 Mbyte (170 K instructions (IL))
Data memory 4 Mbyte
Retentive data memory 96 kByte (NVRAM)
Number of data blocks (depending on data memory)
Number of timers, counters (depending on data memory)
Number of control tasks 16
Realtime clock Integrated (battery-backed)
Power supply
Supply voltage 24 V DC
Range of supply voltages 20 V DC ... 30 V DC (including ripple)
30 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Applied for:
uP UL Listed / CUL Listed
Pcs. / Pcs. /
Type Order No. Type Order No.
Pkt. Pkt.
PSM-AD-D9-NULLMODEM 2708753 1
5 5
3 3
0.05 ms 0.005 ms
Typ. 8 Mbyte (680 K instructions (IL)) Typ. 8 Mbyte (680 K instructions (IL))
16 Mbyte 16 Mbyte
96 kByte (NVRAM) 240 kByte (NVRAM)
(depending on data memory) (depending on data memory)
(depending on data memory) (depending on data memory)
16 16
Integrated (battery-backed) Integrated (battery-backed)
24 V DC 24 V DC
20 V DC ... 30 V DC (including ripple) 19.2 V DC ... 30 V DC (including ripple)
1.5 A 1A
122 mm 122 mm
181 mm 181 mm
182 mm 182 mm
IP20 IP20
0°C ... 55°C (from 45°C only with fan module) 0°C ... 55°C (from 45°C only with fan module)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 31
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Multifunctional controller
S-MAX 4xx CE PN
Status display LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics)
32 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Controllers as per IEC 61131
Fx
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
VISU+ 2 ... (see software) VISU+ 2 ... (see software) VISU+ 2 ... (see software)
PC WORX ... (see software) PC WORX ... (see software) PC WORX ... (see software)
S-MAX 415 CE PN S-MAX 417 CE PN
12.1" TFT active 12.1" TFT active 15" TFT active 17" TFT active
800 x 600 800 x 600 1024 x 768 1280 x 1024
250 cd/m² typ., (adjustable) 250 cd/m² typ., (adjustable) 250 cd/m² typ., (adjustable)
Resistive industrial touch screen Resistive industrial touch screen Resistive industrial touch screen
On-board graphics chip (AGP) On-board graphics chip (AGP) On-board graphics chip (AGP)
DVI DVI DVI
3x Ethernet (10/100 Mbit), RJ45 3x Ethernet (10/100 Mbit), RJ45 3x Ethernet (10/100 Mbit), RJ45
LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics) LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics) LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics)
Typ. 0.05 ms (1 K bit instruction) Typ. 0.05 ms (1 K bit instruction) Typ. 0.05 ms (1 K bit instruction)
8 Mbyte (680 K instructions (IL)) 8 Mbyte (680 K instructions (IL)) 8 Mbyte (680 K instructions (IL))
16 Mbyte 16 Mbyte 16 Mbyte
120 kByte (NVRAM) 120 kByte (NVRAM) 120 kByte (NVRAM)
(depending on data memory) (depending on data memory) (depending on data memory)
(depending on data memory) (depending on data memory) (depending on data memory)
16 16 16
12 12 12
4 4 4
24 V DC 24 V DC 24 V DC
19 V DC ... 29 V DC (including ripple) 19 V DC ... 29 V DC (including ripple) 19 V DC ... 29 V DC (including ripple)
2A 2A 2A
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 33
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
34 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Software
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 35
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software – Technical description
36 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software – Technical description
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 37
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software – Product overview
Config
Type PROJECT+ FL WST BASIC CONFIG+ AX+ BASIC IBS CMD SWT G4 ...
Order No. 2988667 2692254 2868059 2985068 27214..
Description Software for planning the I/O Simulation software to support the Software for configuration and FDT container for integration of Software for configuration of the
configuration planning of wireless systems in diagnostics of networks DTM devices fieldbus
industrial environments
Page 40 41 47 44 45
Programming
Page 43 43 65 92 111
Programming
Type RESY-DATA-A LIC SAFETYPROG 2.x ... PC WORX 3.0X CONTROL ... UM DE BACL APPLICATION SOFTWARE LICENCE
Order No. 2876847 ... 2739405 2910686 2988625
Description Remote control technology license Function block library for INTERBUS License for control function blocks Function block library for building License for SQL/MySQL
Safety systems automation communication with databases
Page 49 111 49 49 49
38 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software – Product overview
Visualization
Page 51 51 53 53
Page 53 53
Page 55 55 57 57
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 39
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Project+ –
I/O configurator
PROJECT+
Software for planning Inline and Fieldline I/O stations
knowledge of the specific configuration Software for planning the I/O configuration PROJECT+ 2988667 1
rules which must be learned and then
Technical data
applied to every individual application. Hardware requirements
Project+ is a configuration tool that CPU Pentium 4/Celeron, 1 GHz
supports you in building your Inline and Main memory 512 Mbyte (1 GB for Windows Vista)
Hard disk memory Min. 200 Mbyte
Fieldline stations. Optical drive CD-ROM
Thanks to automatic product selection Operating equipment Keyboard, mouse
Software requirements
and product composition mechanisms as Operating systems MS Windows 2000 SP4, MS Windows XP SP2 (recommended),
well as the intuitive user interface, Project+ MS Windows Vista Business
reduces the configuration effort for I/O Software requirements MS WORD 2003 or a higher version
Basic functionality
stations significantly. Automatic selection and composition of Inline and Fieldline modules
In order to build an I/O station, only the
Automatic selection of the required accessories
desired input and output functions must be Graphical presentation of Inline and Fieldline stations
entered. Project+ automatically generates
Manual product selection with program support
an economical and technically optimum
solution on the basis of this data. All Manual selection of accessories
programming guidelines are taken into Automatic creation of parts lists
Automatic calculation of currents and consideration of system
account, currents are calculated and the guidelines
necessary infrastructure elements such as Consideration of release lists
Languages supported
power terminals and system cables are German, English, Spanish, French, Italian, Dutch, Russian
automatically added to the system
structure. The stations can also be manually
processed. Inline controllers are also
included in Project+. You can thus plan
entire control systems along with their I/Os
in Project+.
The stations created in Project+ are
technically correct and can therefore be
used directly in the further engineering
process. The results can be copied to the E-
CAD tools parts lists. Data export into the
Clip Project software enables completion
and labeling of complete DIN rails.
The graphics created in Project+ can be
added to the project documentation and
used a structuring help for the real station.
40 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
FL WST Basic –
Wireless simulation software
FL WST BASIC
Simulation software
optimal wireless coverage. Even a layman in Demo version of simulation software to support the planning of FL WST BASIC DEMO CD 2692377 1
wireless systems in industrial environments (limited memory
the field of wireless transmission can do the options, no print function)
wireless planning in just a few steps.
Simulation software to support the planning of wireless systems FL WST BASIC 2692254 1
A typical WLAN installation in a factory in industrial environments
hall often requires less than 30 minutes. As
compared to the usual trial and error Technical data
Hardware requirements
methods, you save considerable time and CPU Min. Pentium 4 / Celeron 1 GHz
nerves. Just one access Point less and the Main memory 512 MB (RAM)
purchase costs for the software are Hard disk memory 500 MB
Optical drive CD-ROM
amortized. Operating equipment Mouse recommended
Software requirements
Integrated library and various views of Operating systems MS Windows XP (SP2), MS Windows Vista
the result Browser Internet Explorer starting from 5.5
Software driver DirectX 9.0c
In the library, the user can find the Basic functionality
elements required to quickly create the Wireless system planning for WLAN and Bluetooth
environment: Various graphical formats as background image for building plans
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 41
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
PC Worx & PC Worx Express –
IEC 61131 programming
IEC 61131 programming with Connection errors are displayed in the Programming environment for 100
PC Worx message window in plain text. The control class PC Worx Express
PC Worx is the uniform automation addressing of variables in the control With PC Worx Express, Phoenix Contact
software as per IEC 61131 for all Phoenix memory is automatic. offers an engineering tool which makes it
Contact controllers. The interface can be selected in any of the easy to program the new compact controllers
This engineering tool that been installed languages. Program comments can up to the performance class 200.
continuously developed further with be exported for translation and reimported This is achieved by a clearly arranged user
numerous users and different partners for as required. This means that projects, interface as well as the reduction of expert
over ten years and is now used in all including the programmer and user functions, among other things. PC Worx
industrial fields. From the very beginning, comments, can be viewed in various Express still offers many of the proven
Phoenix Contact has focused on a uniform languages. PC Worx functions such as project
engineering environment for all control The integrated password handling creation, quick application development as
classes. User friendliness in regard to supports different protection types, such as well as easy downloading, monitoring and
reusable programs and functions is also saving the entire project, read/write startup of the PLC program. Intelligent
taken into account in PC Worx. protection for a single POU (expertise automated processes like automatic
The interface provides a quick and simple protection) or disabling actions such as PLC insertion of program instances into the task
project overview. Windows, which are start/stop. or simplified variable handling accelerate the
designed as folders, simplify operation. A simulation that can be used for advance programming process.
Dock-on and dock-off work spaces and testing of the programs on the PC is PC Worx Express can be downloaded
configurable tool bars that can be adapted available for all INTEL®-compatible free of charge at www.phoenixcontact.com.
easily to the user's requirements increase controllers, in order to make it possible to If the application requires the extended
programming efficiency. test the program code as early as possible. functions of PC Worx, the project created
The software contains the following This shortens the startup times for the real with PC Worx Express can be opened with
programming languages defined in the IEC system. the standard programming environment in
1131-3 standard: The logic analyzer offers realtime data order to transfer the created data into
– Instruction list (IL) acquisition for all variables, including PC Worx. Your know-how is retained.
– Function block diagram structural and array elements, that are
– Ladder diagram (LD) added directly from the worksheet. A long-
– Fixed format ladder editor term recording on a hard disk is also
– Sequential function chart possible.
– Structured text All data planned in PC Worx can be
reused for visualization purposes in an easy
The basic IEC 61131 languages (LD, FBD manner. The INTERBUS OPC server and a
and IL) can be compiled directly or cross- web server can be used to connect to the
compiled as required. The program code, visualization and control level. The OPC
which is written in structured text, can be and WebServer variables are selected with
translated into any of the three basic a mouse click.
languages as prescribed by IEC conventions. The diagnosis of all system components in
To increase the speed and convenience of the INTERBUS and PROFINET network is
editing, all editors feature selection tools handled through the integrated diagnosis
that support and monitor the insertion of tool Diag+. Diag+ enables precise error
data types, function blocks, operators and localization in the system. The diagnostics
variable declarations. The text editors have can be stored in the parameterization
an additional assistant for key words and memory of the controllers as an option and
their command structures. read out as required.
PC Worx has an integrated bus
configurator for project planning of
network structures. It supports INTERBUS
and PROFINET IO networks. Other
fieldbus systems can be configured via
proxies in connection with a device
description file. The configurator device
catalog lists all the necessary components in
easy-to-understand groupings. The
components can be selected for the
hardware configuration using drag & drop
operations.
The program variables are also connected
with the inputs and outputs of the
components by means of drag & drop
operations in the Connection view.
42 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Free programming version without a license mechanism for the PC WORX EXPRESS 2988670 1
100 control class, 64 kByte input data and 64 kByte output data
Demo software with quick start guide, 16 byte input/output PC WORX DEMO 2985725 1
data, Diag+ limited to 5 devices
Basic license with 256 byte input/output data, without MSFC PC WORX BASIC LIC 2985275 1
compiler
Full license with 128 KByte input/output data, with MSFC PC WORX PRO LIC 2985385 1
compiler included
Low-cost upgrade of existing basic license to a full license PC WORX BASIC-PRO LIC 2985259 1
Technical data
Hardware requirements
CPU Min. Pentium 4 / Celeron 1 GHz Min. Pentium 4 / Celeron 1 GHz
Main memory Min. 512 Mbyte (1 GB for Windows Vista) Min. 512 Mbyte (1 GB for Windows Vista)
Hard disk memory Min. 2048 Mbyte Min. 2048 Mbyte
Optical drive DVD-ROM DVD-ROM
Operating equipment Keyboard, mouse Keyboard, mouse
Monitor resolution XGA (1024 x 768) XGA (1024 x 768)
Software requirements
Operating systems MS Windows 2000 SP4, MS Windows XP SP2 (recommended), MS Windows 2000 SP4, MS Windows XP SP2 (recommended),
MS Windows Vista Business MS Windows Vista Business
Supported browsers Internet Explorer 5.5 or higher Internet Explorer 5.5 or higher
Basic functionality
Planning an automation system, parameterizing INTERBUS and Planning an automation system, parameterizing the INTERBUS and
PROFINET devices, operating INTERBUS and PROFINET, PROFINET devices, operating INTERBUS and PROFINET,
programming an automation system with a contact plan (KOP/LD) programming an automation system in acc. with IEC 61131-3,
and structured text (ST), communication as per IEC 61131-5 communication in acc. with IEC 61131-5
Network configuration (functionality of Config+) IEC 61131 includes the following programming languages:
-Instruction list (IL), -Function block diagram (FBD), -Ladder
diagram (LD), -Structured text (ST), -Symbolic flowchart (SFC)
Network diagnostics (functionality of Diag+) Add-on to IEC 61131: Fixed Format Ladder Editor (FFLD) and
Machine Sequential Function Chart language MSFC (from the
license PC WORX PRO LIC onwards)
- Network configuration (functionality of Config+)
128 kbyte input and output data 128 kbyte input and output data (full license)
Languages supported
German, English, French, Italian, Spanish, Chinese German, English, French, Italian, Spanish, Chinese
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 43
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
AutomationXplorer+ –
Device configurator
Languages supported
German, English, French, Spanish, Italian
44 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
IBS CMD SWT G4 –
Fieldbus configurator
Technical data
Hardware requirements
CPU Min. 80486/ 33 MHz
Main memory > 10 Mbyte
Hard disk memory 62 Mbyte
Optical drive CD-ROM
Interfaces Free serial interface for online connection
Basic functionality
Planning of the INTERBUS structure
Planning of the address assignment
Writing the parameterization memory
Parameterizing the INTERBUS devices
Operation and display of current status
Mouse or keyboard operation
Languages supported
German, English, French, Spanish
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 45
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Config+ –
Fieldbus / network configurator
Config+ is a software tool for simple Multiple devices, e. g. network Factory Line products that are supported
project planning, startup and maintenance components such as managed switches or by the MDC wizard:
of INTERBUS and Ethernet networks. various IO link sensors/actuators, can be – FL SWITCH MM HS
The INTERBUS configuration can be parameterized together with a single (Order No. 2832328)
done manually or read in from the system. command using the Multiple Device – FL SWITCH MM HS/M
Configuration wizard (MDC wizard). (Order No. 2832522)
Config+ allows the connection of Redundancy mechanisms such as Rapid- – FL SWITCH MCS 16TX
external software via FDT interface. Spanning Tree (RSTP as per IEEE 802.1w), (Order No. 2832700)
This means that special device user MRP (as per IEC 62439) can thus be – FL SWITCH MCS 14TX/2FX
interfaces for internal or external devices switched on simultaneously and (Order No. 2832713)
(DTM) can be directly integrated in Config+ parameterized for several selectable – FL SWITCH SMCS 8GT
and the relevant devices can be devices. Functions such as Trap-Receiver, (Order No. 2891123)
parameterized. LLDP, VLANs, etc. can also be – FL SWITCH SMCS 6GT/2SFP
parameterized in this manner using the (Order No. 2891479)
When the INTERBUS Safety system is MDC wizard. Device functions do not have – FL SWITCH SMCS 6TX/2SFP
used, the network topology created in to be changed via the WEB management. (Order No. 2989323)
Config+ can be directly transferred to the – FL SWITCH SMCS 8TX PN
safe SafetyProg programming tool (called up (Order No. 2989103)
from Config+). – FL SWITCH SMCS 4TX PN
(Order No. 2989093)
In the event of an error, the integrated – FL SWITCH LM 5TX
Diag+ diagnostic functions ensure fast and (Order No. 2989527)
clear error localization through graphical – FL SWITCH LM 8TX
displays and plain text messages. (Order No. 2832632)
– FL SWITCH LM 4TX/2FX
(Order No. 2832658)
– FL SWITCH LM 4TX/2FX ST
(Order No. 2989132)
– FL SWITCH LM 4TX/2FX SM
(Order No. 2891916)
46 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Config
Function overview for network
configuration
– Configuring INTERBUS and Ethernet
networks
– Reading and comparing real and planned
topology
– Automatic address allocation or via "drag
& drop"
– Parameterization of the master boards or
controller boards, even several boards in CONFIG+
one project Fieldbus / network configurator
– IP address allocation via BootP server
– Device parameterization through FDT via
DTM that can be integrated
– Parameterization of several devices with
assistant support (MDC wizard) Description Type Order No.
Pcs. /
Pkt.
– Monitor function to check the wiring
Config+ demo version with restricted range of function (it is not CONFIG+ DEMO 2868046 1
possible to save projects)
INTERBUS diagnostics (Diag+) Config+ full version for configuration and diagnosis of networks CONFIG+ 2868059 1
– Graphical display of error location in
Config+ copy license makes it possible to install the Config+ CONFIG+ CPY 2868062 1
network topology software several times. A Config+ full version is necessary as well.
– Clear text messages with suggested When ordering, please state the number of licenses you need.
remedies
– Online display of device statuses Technical data
– Statistics functions for transmission Hardware requirements
CPU Pentium 4/Celeron, 1 GHz
qualities Main memory Min. 512 Mbyte (1 GB for Windows Vista)
– Saving comments about error messages Hard disk memory Min. 2048 Mbyte
on the PC or master Optical drive
Interfaces
DVD-ROM
COM port, Ethernet, (ISA or PCI with INTERBUS master card in the
PC)
Operating equipment Keyboard, mouse
Ethernet diagnostics Monitor resolution XGA (1024 x 768)
– Trap receiver functionality in integrated Software requirements
Operating systems MS Windows 2000 SP4, MS Windows XP SP2 (recommended),
diagnostics view (Diag+) MS Windows Vista Business
– Graphical Ethernet topology (2D view) Supported browsers Internet Explorer 5.5 or higher
Termination boards supported
with display of the accessibility of devices IBS S7 400 ETH SDSC/I-T 2819558
– Display of redundancy paths, port IBS S7 400 ETH DSC/I-T 2731102
IBS S7 400 DSC/I-T 2719962
statistics, virtual LANs as well as other IBS S7 300 DSC-T 2719975
properties that can be read out via SNMP IBS PCI SC/RI/I-T 2730637
IBS PCI SC/RI/I-T 2730080
– Calling up device websites (if available) IBS PCI SC/RI-LK 2730640
IBS PCI SC/RI-LK 2730187
IBS PCI SC/I-T 2725260
FL IL 24 BK-B-PAC 2862327
FL IL 24 BK-PAC 2862314
FL NP PND-4TX IB 2985974
FL NP PND-4TX IB-LK 2985929
FLM BK ETH M12 DI 8 M12-2TX 2736916
IL ETH BK DI8 DO4 2TX-PAC 2703981
Basic functionality
Project transfer to SafetyProg (software tool for programming
INTERBUS Safety)
Project planning of Ethernet configurations
Planning of the address assignment
Transfer of the address settings (address ranges, assignment list)
from Step 7®
Project planning of multimaster projects (several bus configurations
in one project)
Comparison between real and planned bus configuration
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 47
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Functional and branch-specific
software and driver
Driver functional blocks In addition, all function blocks of the Economical data acquisition with SQL
A variety of specialized peripheral BACL offer a communication interface as The volume of data involved in industrial
modules and modules with directly well as visualization software. processes is increasing continuously and can
integrated functionalities are offered along Software for PC Worx for building only be managed by using databases. While
with easy-to-use I/O modules especially for automation is available as freeware on CD- cyclical protocols such as OPC or BACnet
automation of production machines for PC ROM: are normally used to save data within
Worx controllers. Free and easy-to-use German manual incl. CD-ROM: UM DE machines and systems, the IT world uses
driver function blocks are also available to BACL (Order No. 2910686). Further SQL for databases.
integrate these complex modules language variants on request. The function block library from Phoenix
conveniently into the PLC programs. Contact carries out this SQL
communication, thus facilitating direct data
ReSy+ – Software for remote control
For the operation of specialized technology transfer between the controller and the
peripheral modules: modules for database for the first time. Other server-
Measurement, control and regulation are
temperature recording, analog input/output side software or additional drivers are no
the basic functions in the supply and
modules, motor starters, position recording discharge fields. Phoenix Contact offers you longer required for data traffic.
terminals for incremental encoders, Thanks to the option of sending SQL
suitable software for smooth system
absolute encoders or magnetostrictive commands to a database directly from the
operation: ReSy+.
encoders, power and weighing sensors, Thanks to the ReSy+ function block controller, all the properties of the Data
modules with counter functions, modules Manipulation Language (DML) are directly
library, remote system parts can be linked
for pulse width generation, modules for available to PLC programmers for the first
comfortably and integrated into your
controlling servo valves, modules with I/O control system. ReSy+ allows uniform time ever.
Link connections, modules for serial The system allows you to read and write
control of all processes and also gives an
communication (RS-232 / RS-485) or for any tables of your database directly from
overview of the entire system. Linking
Modbus communication (client and server). existing systems is also an easy task for the the PLC program, thus in an event-
controlled manner. The network load can
open ReSy+. Our ReSy+ software
For the operation of distributed thus be drastically reduced by eliminating
communicates on the basis of international
functional modules: low-power servo remote control standards (IEC 60870-5- cyclical protocols.
amplifiers, F/Us and servo amplifiers, APPLICATION SOFTWARE LICENCE
101/104) using our proven control and I/O
distributed positioning terminals, (order no. 2988625)
components.
distributed temperature controllers, and RESY+-DATA-A LIC (order no. 2876847)
step motor control.
Software for machine automation
You can get the driver function blocks
PID controller for general process The performance of machines is
free of cost on the product page of the determined by control functions that are
relevant module at control applications
nowadays created using IEC 611313-
http://www.phoenixcontact.net under the This function block library offers basic
control functions that can implement a compatible application software. These are
Download item. based on specifically developed software
variety of control tasks in industrial and
algorithms for high-performance platforms.
process automation.
Software for building automation In all applications in which compact Phoenix Contact offers the Plast-Max
With PC Worx, the project engineers software library for a special application
controllers have been used so far, control
have an easy-to-use automation software at area; it provides regulation know-how for
tasks can now be carried out economically
their disposal for all Phoenix Contact by PC Worx controllers with the help of plastic machines. It represents a flexible
controllers that are used in building automation solution for plastic machines,
these function blocks.
automation as DDC controllers. together with the distributed I/O systems
The blocks contain a full-fledged PIDTz
Your building software can be optimally controller (PID controller with delay time Inline and Fieldline.
adapted to your requirements on the basis Plast-Max is an extensive application
constant in the D part). Two-position,
of the worldwide standard IEC 611313 with software comprising a status machine with
three-position or motor step closed-loop
the help of pre-assembled, tested and controls can also be implemented. integrated diagnostics and regulation
documented function blocks. The functions for hydraulic and electrical axes
PC WORX 3.0X CONTROL
programming effort is thereby reduced to a adapted to the respectively required
TECHNOLOGY (order no. 2739405)
minimum, and a high level of standardization performance of the controller.
is achieved. Plast-Max function block library and the
The "Building Automation Control relevant user interface based on Visu+
Library" (BACL) function block library also
supports you in the programming of
heating, ventilation and climate control as
well as in single room control or lighting
control.
48 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 49
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Visu+ and WebVisit for SCADA or
web-based visualization
50 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
MS Windows 2000 SP4, MS Windows XP SP2 (recommended), MS Windows 2000 SP4, MS Windows XP SP2 (recommended), MS Windows 2000 SP4, MS Windows XP SP2 (recommended),
MS Windows Vista Business, MS Windows CE MS Windows Vista Business, MS Windows CE MS Windows Vista Business
Internet Explorer 5.5 or higher Internet Explorer 5.5 or higher Internet Explorer 5.5 or higher
Full SCADA (Supervisory Control And Data Acquisition) Full SCADA (Supervisory Control And Data Acquisition) Visualization system of control variables
functionality with visualization, trending and alarm management functionality with visualization, trending and alarm management
Multilingualism of software and projects (incl. Unicode support and Multilingualism of software and projects (incl. Unicode support and Visualization system with web technologies
online toggling) online toggling)
Know-how protection and safety through encoding of projects Know-how protection and safety through encoding of projects Java-Applet-based user interface
Control coupling with OPC Control coupling with OPC and 2 direct drivers Visualization system can be viewed using a web browser
Access protection with user management Access protection with user management -
Fully scalable process diagrams for using one design on different Fully scalable process diagrams for using one design on different -
devices and monitor sizes devices and monitor sizes
Realtime database coupling with ODBC to MS ACCESS, MS Realtime database coupling with ODBC to MS ACCESS, MS -
EXCEL and SQL server EXCEL and SQL server
Automatic data recording and recipe management Automatic data recording and recipe management -
Scripts can be created in VBA and IL Scripts can be created in VBA and IL -
FDA CRF 22 Part 11 compatible FDA CRF 22 Part 11 compatible -
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 51
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Software for OPC servers
52 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Pentium 4/Celeron, 1 GHz PC Pentium > 266 MHz PC Pentium > 266 MHz
512 Mbyte (1 GB for Windows Vista) Min. 32 Mbyte Min. 32 Mbyte
2048 Mbyte (1 GByte recommended) Min. 20 Mbyte Min. 20 Mbyte
DVD-ROM CD-ROM CD-ROM
Keyboard, mouse Keyboard, mouse recommended Keyboard, mouse recommended
Embedded controller (INTERBUS controller boards are supported - -
only by the IBS OPC SERVER.)
MS Windows XP, MS Windows 2000 Windows 2000, Windows NT, Windows XP, TCP/IP stack, Windows 2000, Windows NT, Windows XP, TCP/IP stack,
(MS Windows Vista Business only for AX OPC SERVER, SNMP agent SNMP agent
MS Windows NT 4.0 SP6 only for IBS OPC SERVER)
- Monitoring and configuration of SNMP-capable devices in HMI and Monitoring of OPC server, access to OPC server, SNMP proxy
SCADA systems, support of SNMP version v1 and v2c; support of agent, support of SNMP version v1 and v2c
the OPC Client OPC Data Access 1.0A/2.0 or OPC Alarm and
Events, integrated MIB browser, support of device profiles,
(import/export and creation of device profiles), online and remote
configuration possible via remote PCs
German, English (French, Spanish only IBS OPC SERVER) German, English German, English
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 53
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
WinMOD –
Software for virtual system operation
WinMOD enables software startup and A network configuration created in Examples of the areas of application:
software testing without the real machine PC WORX or Config+ including the agreed – Validation of control programs and
or system. variables/symbols can be directly function blocks
For this, the real controller is connected transferred to the WinMOD simulation – Safe simulation of extreme operating
with the WinMOD simulation PC via the software via a data interface. conditions (crash tests without the risk of
configured fieldbus system or an equivalent. WinMOD already has various simulation personal injury, loss of time and material
The control behavior of the real system is blocks for frequently used process blocks, costs)
simulated in realtime by a WinMOD e. g. drives. These are supplemented with – Illustration of motion sequences in 3D
project. The network configuration the user's own blocks and are connected to visualization with a link to the controller
behavior can also be simulated and can be create a complete system simulation. Here, (add-on is required)
exposed to error states for testing the variables/operands from PC WORX are – Allows training courses on virtual systems
purposes. linked with the inputs/outputs of the incl. simulation of malfunction scenarios
simulation blocks. – Virtual commissioning
The advance startup that is possible using – Factory acceptance test (FAT)
WinMOD saves a considerable amount of – Realtime-compatible simulation of any
time during the actual startup, since the processes/applications
application programs can be created parallel
to the system configuration and can be
tested thoroughly in advance.
54 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Simulation software
WINMOD AX ...
Pcs. /
Description Type Order No.
Pkt.
WinMOD system software incl. INTERBUS configuration software1) WINMOD AX IB 2988418 1
Software requirements
Operating systems Windows 2000, Windows XP (recommended)
Languages supported
German, English
IB EMULATOR
Pcs. /
Description Type Order No.
Pkt.
INTERBUS simulation hardware
IB EMULATOR 2988638 1
Technical data
Interface
Fieldbus system INTERBUS
Name INTERBUS remote bus
General data
Weight 820 g
Width 75 mm
Height 185 mm
Depth 190 mm
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 55
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Diag+ and Diag+ Netscan –
Network diagnostics
Diag+ diagnostics tool for INTERBUS, The network configuration data created Ordering example 1:
PROFINET and Ethernet networks with CMD, Config+ or PC WorX during the Diag+ software is to be installed on 10
Diag+ is a special diagnostics tool adapted configuration, e.g. your own comments, different PCs in a system for INTERBUS
to PROFINET IO and INTERBUS that equipment identification codes or station network diagnostics and linked from each
signals both network errors and the current names, are read and displayed with Diag+ one to the existing visualization system as
states of controllers and devices. Preventive from the parameterization memory of the an ActiveX control. The diagnostic data
diagnostic functions such as the monitoring controller board. This greatly simplifies delivered by Diag+ will be processed further
of transmission quality of FO paths orientation within the plant. in the visualization system itself.
(INTERBUS) increase the plant availability. – 1x DIAG+
Fast startup
The tool can be operated independently or – 9x DIAG+ CPY
During startup, installed buses can be
integrated as an ActiveX control directly in Ordering example 2:
other Windows applications (e.g. tested very easily: Commands are available
to start the bus, to acknowledge error From a control room, INTERBUS
visualization systems). Via a programming
messages, to switch INTERBUS devices on controller boards (x 60) with lower level
interface, the diagnostics data can be subnetworks connected via INTERBUS
further processed in the visualization. and off, to bridge the devices and to stop
the bus using an alarm stop. The bus cabling system couplers (only possible with PCP ID
Familiar functionalities for INTERBUS
can therefore be checked very quickly. code) are to be monitored via Ethernet.
systems, such as the display of status When a fault occurs, the detailed diagnostic
information, operating functions, plain Access to lower-level subordinate bus
systems, using system couplers for example, data will be read out and displayed manually.
language error messages with debugging
is also possible using Diag+. – 1 x DIAG+ NETSCAN
tips or detailed information about device
types and states have been added with Diag+ Netscan Software for cyclical
PROFINET I/O-specific diagnostic diagnostics of INTERBUS networks
functions. The PROFINET topology is Diag+ NetScan enables simultaneous
represented analogous to the INTERBUS monitoring of INTERBUS networks with
structure. Color symbols on the devices, several controller boards/controllers. The
modules and submodules indicate the transmission quality of all FO paths in an
current status or certain errors of the entire system is thus monitored
devices/modules. All state and error permanently. Even lower-level buses
messages are read out from the retentive connected using system couplers can be
diagnostic messages archive of the included in monitoring.
controller. With the help of filter functions,
certain message types can be simply
determined in the archive view of the
software. In a graphical view of the Ethernet
device topology, the differences between
the set and actual configuration are also
displayed.
56 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Software
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Diag+ demo, limited scope of functions (only valid for the first five DIAG+ DEMO 2730734 1
stations)
Diag+ full version, for INTERBUS diagnostics (ActiveX control IBS DIAG+ SWT 2730307 1
with programming interface)
Diag+ copy license, allows you to install Diag+ software more DIAG+ CPY 2730404 1
than once. A Diag+ full version is necessary as well. When
ordering, please state the number of licenses you need.
Diag+ NetScan-Demo, limited scope of functions (cannot open or DIAG+ NETSCAN DEMO 2868091 1
save projects)
Diag+ NetScan full version, for cyclic and simultaneous network DIAG+ NETSCAN 2868075 1
diagnostics (ActiveX control)
Diag+ NetScan copy license, allows you to install Diag+ NetScan DIAG+ NETSCAN CPY 2868088 1
software more than once. A Diag+ NetScan full version is
necessary as well. When ordering, please state the number of
licenses you need.
Technical data
Hardware requirements
CPU Pentium 4/Celeron, 1 GHz Pentium 4/Celeron, 1 GHz
Main memory Min. 512 Mbyte (1 GB for Windows Vista) Min. 512 Mbyte (1 GB for Windows Vista)
Hard disk memory Min. 2048 Mbyte Min. 2048 Mbyte
Optical drive DVD-ROM DVD-ROM
Interfaces Serial interface, Ethernet, ISA bus, PCI Serial interface, Ethernet connection or ISA bus, parallel interface
(LPT1...LPT2)
Supported interface connections INTERBUS controller board of the 4th generation, PROFINET I/O INTERBUS Generation 4 controller board
Controller (Phoenix Contact only)
Software requirements
Operating systems MS Windows 2000 SP4, MS Windows XP SP2 (recommended), MS Windows 2000 SP4, MS Windows XP SP2 (recommended),
MS Windows Vista Business MS Windows Vista Business
Basic functionality
Executing important commands (start/stop/...) Executing important commands (start/stop/...)
Reading in the installed bus structure Reading in the installed bus structure
Detecting/representing error states (plain text from knowledge Detecting/representing error states (plain text from knowledge
database) database)
Saving diagnostics data in flash memory or parameterization Saving diagnostics data in flash memory or parameterization
memory of the controller board memory of the controller board
Diagnostics of INTERBUS FO paths (transmission quality) Diagnostics of FO paths (transmission quality)
Can be integrated into other 32-bit applications as ActiveX control Can be integrated into other 32-bit applications as ActiveX control
including programming interface for further processing of all
diagnostic data
Languages supported
German, English, French, Spanish, Portuguese (Brazilian), Italian, German, English, French, Spanish
Chinese
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 57
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
58 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Flow chart programming
Steeplechase VLC –
The leading PC-based control Program overview
software with flow chart
programming Technical description 60
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 59
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
Flow chart programming – Technical description
60 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
Flow chart programming – Technical description
HMI options Flow chart and RLL editors Boolean and bit operators
Steeplechase VLC offers two HMI – Direct tag names editor +, ++, <, >, <<, >>, <=, >=, NOT, AND,
software choices — Citect HMI or Iconics – 63 character tag names, OR, XOR, MOD, ON, OFF, TRUE, FALSE,
MachineWorX. Both offer the ability to 1024 character descriptions COMMENT, <>, +, –, /, bit, set, bit pick, bit
create sophisticated animations and screens – Drag-and-drop support rotate
that display control system operating status – Cut-copy-paste support
as well as trending and alarming data. – Library and template support Mathematical functions:
Steeplechase VLC also has an integrated through subprograms
A total of 38 functions, including
OPC server to provide runtime information – Grid, snap-to, and auto-alignment
trigonometric, hyperbolic, exponentiation,
to any HMI or OPC client application. of logic blocks array processing and conversion functions.
– User-defined preferences
– Floating, dockable toolbars
String functions
Total enterprise connectivity – Built-in version control for projects
– Autolaunch of VLC, HMI, and Windows® Compare, left, right, mid, set, case,
In addition to OPC, Steeplechase
programs no case.
Transaction Express provides HMI-
independent access to Steeplechase VLC
runtime data. You can use Transaction Berkley sockets
Flow chart programming
Express to move data to and from an Over TCP/IP in real-time Berkley
enterprise SQL database for error proofing, – Action block
– Decision block sockets send and receive TCP/IP packets
recipe management, fault logging, birth using the socket interface directly from
– Branch/merge block
history, build instructions and asset flow chart or RLL programs.
utilization. The integration of Microsoft – Exception blocks (begin and end)
– Start and stop blocks
Message Queuing (MSMQ) guarantees data
– Subroutine/subprogram call, including Integrated motion
delivery.
parameters passed by reference, value
and as read-only VLC supports MEI and Galil motion
– Diagnostic decision wizard cards to provide integrated motion system
Runtime support up to 64 axes. Motion, logic, and
– Scan-based architecture; – Special I/O function block, diagnostics,
motion control, PID, etc. HMI are combined into one PC platform.
repeatable performance The motion system includes the following:
– Comment blocks
– User-selectable scan rate – Absolute moves
– Fast execution with scan rates – Incremental moves
as low as 200 µs – Homing functions
Ladder diagram programming
– Automatic watchdog timer – Blended moves
– Watch window and instant watch – Flow chart enhanced
– Contacts – NO, NC, rising edge, – Master/slave moves
– Data tips – Position-triggered moves
falling edge
– Execution tails – current and historical – Stop, e-stop
– Remote and RAS programming – Coils – output, inverted, latch, unlatch
– Branch capability – Up to four--axes coordinated moves
– Online cross-referencing – Two-axes arc coordinated moves
– Counter block
– Online programming – Velocity change on the fly
– Timer on delay, timer off delay and
retentive timers – Simultaneous multi-axis coordinate
– Action blocks – Camming
– Decision blocks – SERCOS
– Special I/O function, diagnostics,
motion control and PID Communications
OPC server, DDE server, DDL
interface, Ethernet, peer-to-peer.
Drivers
Steeplechase VLC supports all popular
fieldbus networks.
For more detailed information, visit
www.phoenixcontact.net/software.
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 61
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
Flow chart programming – Product overview
Type VLC-...-P VLC-...-USB Type ILC 150 VLC ILC 350 VLC
Order No. 560... 560... Order No. 2985783 2985013
Description Development environment with Development environment with Description Inline controllers Inline controllers
flow chart programming and flow chart programming
hardware key for and hardware key for USB
parallel interface
Page 65 65 Page 66 66
62 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
Flow chart programming – Product overview
S-MAX with VLC Runtime and S-MAX with VLC Runtime and
Iconics MachineWorX Runtime Citect HMI Runtime
Type S-MAX 5012 VLC MWX ETH S-MAX 5015 VLC MWX ETH S-MAX 5012 VLC CIT ETH S-MAX 5015 VLC CIT ETH
Order No. 2895653 2895802 2895695 2895844
Type S-MAX 5012 VLC MWX IB S-MAX 5015 VLC MWX IB S-MAX 5012 VLC CIT IB S-MAX 5015 VLC CIT IB
Order No. 2895682 2895831 2895792 2895873
Type S-MAX 5012 VLC MWX PB S-MAX 5015 VLC MWX PB S-MAX 5012 VLC CIT PB S-MAX 5015 VLC CIT PB
Order No. 2895679 2895828 2895763 2895860
Type S-MAX 5012 VLC MWX DN S-MAX 5015 VLC MWX DN S-MAX 5012 VLC CIT DN S-MAX 5015 VLC CIT DN
Order No. 2895666 2895815 2895750 2895857
Description Combination of PLC, PC platform, Combination of PLC, PC platform, Combination of PLC, PC platform, Combination of PLC, PC platform,
visualization and fieldbus master, visualization and fieldbus master, visualization and fieldbus master, visualization and fieldbus master,
12.1" display 15" display 12.1" display 15" display
Page 67 67 67 67
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 63
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Flow chart programming
Flow chart programming with
Steeplechase VLC
Steeplechase VLCTM: powerful and Fast, deterministic, reliable Scalable control platform
intuitive PC-based control software Steeplechase VLC offers one of the Steeplechase VLC was developed
Steeplechase VLC is the leading control fastest and most deterministic PC-based together with the ILC 150 VLC, the ILC 350
software in the field of the flowchart control solutions. Cycle times of up to 200 VLC and the S-MAX VLC product range.
programming language. The new Version 7 µs allow you to process of sophisticated The new Embedded Controllers from
speeds up and simplifies the development of applications. The Steeplechase VLC runtime Phoenix Contact offer users a complete and
control programs. The efficient runtime system is based on a realtime operating scalable control family with a seamless
system from Steeplechase VLC enables scan system that is immune to Windows crashes. programming software solution – from the
times of less than 1 ms on suitable PCs. The Other functions include: compact ILC 150 VLC to the S-MAX VLC
intuitive programming tools speed up the – Monitoring of current and historic steps family right up to high-end control solutions
design cycle and reduce the installation and – Display of forced variables and I/O nodes with industrial PCs.
start up duration. To simplify the switch to – Instant Tag Watch Window Visualization options
conventional PLCs, Steeplechase VLC also – Online cross-referencing
With the Steeplechase VLC, you can
supports the ladder diagram programming – Online programming of flow chart
choose from two optional visualization
language. diagram and ladder diagram programs packages – Citect HMI or the new Iconics
Versatile program options Extended development environment MachineWorX. Both packages offer the
In addition to the programming The new Connection Tree and user sophisticated possibilities for graphical
environment for normal control tasks, Connection Editor simplify the definition of presentation of machine information as well
Steeplechase VLC also supports more I/O modules. The new tree structure offers as trend and alarm messages. Moreover,
complex devices such as Servo-drives or up an improved overview of the layout of the Steeplechase VLC offers an integrated OPC
to 128 PID controllers. The VLC connected I/O system. Projects that were server for each data exchange with all OPC
programming tools are the most created with older versions of Steeplechase client-capable software packages.
progressive in the market and include a VLC, can easily be converted for you to Company-wide networking
variety of mathematical, string and enjoy the new benefits.
In addition to supporting OPC data, the
trigonometric functions as well as The new Target Manager makes it
Steeplechase Transaction Express gives you
instructions from the world of high-level possible to upload and download VLC easy HMI-independent access to runtime
languages, such as While-Do and If-Then- projects of the new embedded control
data. Transaction Express makes loading and
Else. systems, such as ILC 150 VLC, ILC 350 VLC
saving in an SQL database possible for error
Unparalleled I/O support and S-MAX VLC The remote function detection, recipe management etc. Secure
enables easy remote programming. Another
Steeplechase VLC supports over 25 data exchange is guaranteed through the
advantage of Steeplechase VLC is the
drivers for all common fieldbus systems. integration of Microsoft Message Queuing
automatic download of new drivers from (MSMQ).
the development environment to the
runtime system. This ensures that the latest
drivers are available on the runtime system.
64 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Flow chart programming
VLC-...-P VLC-...-USB
Development environment with flowchart programming and Development environment with flowchart programming and
hardware key for parallel interface hardware key for USB
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Professional developers kit: VLC control development VLC-PDK-CIT-P 5603718 1
environment and Citect HMI with one runtime and one hardware
key each for parallel interface
VLC runtime with hardware key for parallel interface VLC-RTM-P 5603720 1
VLC and Iconics MachineWorX HMI Runtime with hardware key VLC-RTM-MWR-P 5606004 1
for parallel interface
VLC and Iconics MachineWorX HMI Runtime with hardware key VLC-RTM-MWR-USB 5606005 1
for USB
VLC Maintainer with hardware key for parallel interface VLC-MNT-P 5606006 1
Relay Ladder Logic Programming, IEC-61131-3-based, flow chart Relay Ladder Logic Programming, IEC-61131-3-based, flow chart
enhanced enhanced
Boolean and bit operations Boolean and bit operations
Mathematical functions Mathematical functions
String functions String functions
Berkeley sockets via TCP/IP in realtime. Berkeley sockets via TCP/IP in realtime.
Integrated motion Integrated motion
Communication via OPC server, DDE server and Ethernet peer-to- Communication via OPC server, DDE server and Ethernet peer-to-
peer peer
Broad I/O driver support Broad I/O driver support
HMI features and options HMI features and options
Languages supported
English English
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 65
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Flow chart programming
Steeplechase VLC and Inline
controller
u u
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Inline controllers, complete with accessories (connector and
labeling field)
- Steeplechase VLC Runtime ILC 150 VLC 2985783 1
Inline controller, complete with accessories (connector and
labeling field) and 64 MB Compact Flash card
Program memory 256 kB (Including the data memory) 1 Mbyte (Including the data memory)
Retentive data memory 8 kByte (NVRAM) 64 kByte (NVRAM)
Number of data blocks (depending on data memory) (depending on data memory)
Number of timers, counters (depending on data memory) (depending on data memory)
Number of control tasks 1 1
Realtime clock Integrated (battery-backed) Integrated (battery-backed)
Power supply
Supply voltage 24 V DC 24 V DC
Range of supply voltages 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC
Residual ripple ± 5% ± 5%
Typical current consumption 200 A (no local bus device connected during idling, bus inactive) 250 mA (no local bus device connected during idling, bus inactive)
General data
Weight 285 g 440 g
Width 80 mm 182 mm
Height 119.8 mm 140.5 mm
Depth 71.5 mm 71.5 mm
Degree of protection IP20 IP20
Ambient temperature (operation) -25°C ... 55°C -25°C ... 55°C
Permissible humidity (operation) 5% ... 90% (no condensation) 5% ... 90% (no condensation)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Vibration resistance in acc. with IEC 60068-2-6 5g DIN EN 60068-2-6
Shock in acc. with IEC 60068-2-27:1997 - DIN EN 60068-2-29
66 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Flow chart programming
S-MAX 50xx VLC ...
The all-in-one control system
U U
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
S-MAX, with Steeplechase VLC and Iconics MachineWorX
Runtime
- MODBUS/TCP-, EtherNet/IP master S-MAX 5012 VLC MWX ETH 2895653 1 S-MAX 5015 VLC MWX ETH 2895802 1
- INTERBUS master S-MAX 5012 VLC MWX IB 2895682 1 S-MAX 5015 VLC MWX IB 2895831 1
- PROFIBUS master S-MAX 5012 VLC MWX PB 2895679 1 S-MAX 5015 VLC MWX PB 2895828 1
- DeviceNetTM master S-MAX 5012 VLC MWX DN 2895666 1 S-MAX 5015 VLC MWX DN 2895815 1
S-MAX, with Steeplechase VLC and Citect HMI Runtime
- MODBUS/TCP-, EtherNet/IP master S-MAX 5012 VLC CIT ETH 2895695 1 S-MAX 5015 VLC CIT ETH 2895844 1
- INTERBUS master S-MAX 5012 VLC CIT IB 2895792 1 S-MAX 5015 VLC CIT IB 2895873 1
- PROFIBUS master S-MAX 5012 VLC CIT PB 2895763 1 S-MAX 5015 VLC CIT PB 2895860 1
- DeviceNetTM master S-MAX 5012 VLC CIT DN 2895750 1 S-MAX 5015 VLC CIT DN 2895857 1
Technical data
Display data
Display 12.1" TFT active 15" TFT active
Monitor resolution 800 x 600 1024 x 768
Display lighting Max. 250 cd/m² typical (adjustable) Max. 250 cd/m² typical (adjustable)
Touch screen Resistive industrial touch screen Resistive industrial touch screen
PLC Data
Main memory 256 MB DDR SODIMM 256 MB DDR SODIMM
Compact flash 512 MB 512 MB
Interfaces COM 1 (RS232), 1xDVI (VGA), 1x PS/2 mouse, 1x PS/2 keyboard, COM 1 (RS232), 1xDVI (VGA), 1x PS/2 mouse, 1x PS/2 keyboard,
2x USB 2x USB
Graphics card On-board graphics chip (AGP) On-board graphics chip (AGP)
Monitor output PnD PnD
Network 3x Ethernet (10/100 Mbps), RJ45, X11: programming and 3x Ethernet (10/100 Mbps), RJ45, X11: programming and
maintenance, X10.1 and X10.2: industrial Ethernet control maintenance, X10.1 and X10.2: industrial Ethernet control
Status display LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics) LEDs (PLC status: PLC, PC status: SYS, fieldbus diagnostics)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 67
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
68 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | High-level language control
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 69
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – Technical description
Controlling with the Windows Solutions under Windows CE and HFI on a PC with Windows XP
technology Windows XP are compatible. A higher- Should the performance of a PC and its
performance device can be selected or an
Today, controlling and visualizing with scalability be used, the High-level Language
XP platform can be used if the performance
the Windows and PC technologies has Fieldbus Interface (HFI) comes into use first.
already become standard in many varied of a CE platform is not adequate. This .NET-compatible class library enables
The Windows platform provides an
applications. At present, the field of easy access to I/O signals. These signals can
ideal basis for the integration of one´s own
programming is undergoing a change; the be connected using Ethernet-compatible
old interface-based programming is remote maintenance concept. Standardized I/O modules or INTERBUS PCI controller
and customer-specific protocols can be
changing into service-oriented .NET boards. I/O signals are accessed through
independently expanded.
programming. This change is also affecting registered variables, the diagnostics is
the world of automation. Windows XP and In addition to control function uniformly displayed and the configuration of
programming, it is also possible to integrate
Windows CE are two compatible operating the network is imported from a
an operating function economically.
systems that support this .NET-technology. configurator.
Due to the .NET technology and the The PC platform provides almost
underlying event-oriented programming,
unlimited performance. Such a solution can
Advantages of high-level language the application can use the CPU power
programming be flexibly expanded with other plug-in
economically. boards, for example for image processing.
The Microsoft .NET development The object-oriented view offers a
Thus, an I/O connection from any .NET-
environment has been tried and tested a number of implementation advantages even
compatible development environment is
million times over and many programmers when there are many recurring elements only a triviality, since it does not require any
are well-versed with it. The programmer and their reusability is given.
special knowledge about networks.
enjoys complete control and almost
unlimited flexibility in his solution.
The development environment can Two compatible solutions
be applied to realistic conditions and is Two different solutions are available for
supported worldwide. No other licensing high-level language applications:
costs apart from those for the operating – Open PC platform with Windows XP
system have to be paid.
Wide propagation of this programming or
automatically ensures future production – Embedded Controller (CP ... HLC ...)
security. This makes the approach useful for with Windows CE
almost all markets and applications.
Functions such as database connection
and web server as well as a TCP/IP stack are
available by default. Sample source codes for
many other functions and protocols are
available for free on the Internet.
70 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – Technical description
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 71
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – Product overview
Type IBS PCI SC/I-T IBS PCI 104 SC-T FL NP PND-4TX IB FL NP PND-4TX IB-LK
Order No. 2725260 2737494 2985974 2985929
Description INTERBUS master INTERBUS master PROFINET proxy and PROFINET proxy and
for PCI interface for PCI/104 Ethernet gateway Ethernet gateway
for INTERBUS for INTERBUS
Type FL IL 24 BK-PAC IL ETH BK DI8 DO4 2TX-PAC ILB ETH 24 DI16 DIO16-2TX FLM BK ETH M12 DI 8 M12-2TX
Order No. 2862314 2703981 2832962 2736916
Type FL IL 24 BK-B-PAC
Order No. 2862327
Description Inline Modular bus coupler Inline Modular bus coupler Inline Block IO station Fieldline Modular bus coupler
72 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – Product overview
Type CP 204M HLC ETH CP 206M HLC ETH CP 206S HLC ETH CP 310T HLC ETH CP 310T HLC ETH IB
Order No. 2916150 2916260 2988340 2916480 2916370
Description High-level language control panel High-level language control panel High-level language control panel High-level language control panel High-level language control panel
with 4" gray scale display with 6" gray scale display with 6" color display with 10" color display with 10" color display
and INTERBUS master
Page 76 77 77 77 77
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 73
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – High-Level language for Fieldbus interface for industrial PCs
74 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control – High-Level language for Fieldbus interface for industrial PCs
The prerequisites:
– PC with the Windows XP (SP2) /
Windows Vista operating system
– .NET Framework 1.1 / 2.0 / 3.0 / 3.5
– I/O devices with direct Ethernet
connection from the Inline Modular,
Inline Block IO or Fieldline Modular
product range (see product overview)
All export information can be converted
The automatic addressing comfort is or
also unparalleled. A simple station into C# or VB using one more automated
step, which is the HFI code generator in – I/O devices for INTERBUS that can be
configurator is called up in bus terminal
source code, for object instances. On addressed using PCI cards or gateways
modules. This configurator can read out the
station and it displays and exports address request, this HFI code generator can also – HFI setup (free download on the Internet
generate a complete application project for devices)
information.
with all class instances, which can be – hardware drivers for PCI cards, if
The popular CMD tool is used in plug-in
boards and gateways. directly compiled. required (free download on the Internet
for controller boards)
– Quick Start with basic information with
the help of examples (free download on
the Internet)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 75
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control
Control panels – Freely
programmable
Ambient temperature (storage/transport) -25°C ... 70°C (Relative humidity 10% to 95%, non-condensing)
76 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
High-level language control
l l
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
1 1 1
RJ45 female connector RJ45 female connector RJ45 female connector
10/100 Mbps 10/100 Mbps 10/100 Mbps
2 2 2
USB type A, female connector USB type A, female connector USB type A, female connector
- - 1
- - 9-pos. D-SUB female
- - 8192 (max.)
Windows CE 5.0 (including web server, Compact Framework 2.0,…) Windows CE 5.0 (including web server, Compact Framework 2.0,…) Windows CE 5.0 (including web server, Compact Framework 2.0,…)
24 V DC ±5% (SELV as per DIN EN 61131) 24 V DC ±5% (SELV as per DIN EN 61131) 24 V DC ±5% (SELV as per DIN EN 61131)
147 mm 340 mm 340 mm
203 mm 270 mm 270 mm
60 mm 60 mm 60 mm
0°C ... 50°C (Relative humidity 10% to 95%, non-condensing) 0°C ... 50°C (Relative humidity 10% to 95%, non-condensing) 0°C ... 50°C (Relative humidity 10% to 95%, non-condensing)
-25°C ... 70°C (Relative humidity 10% to 95%, non-condensing) -25°C ... 70°C (Relative humidity 10% to 95%, non-condensing) -25°C ... 70°C (Relative humidity 10% to 95%, non-condensing)
IP65 (front), IP20 (back) IP65 (front), IP20 (back) IP65 (front), IP20 (back)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 77
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
78 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology | nanoLine® family of controllers
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 79
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers – Technical description
Smart, simple, connected and flexible
Base unit
Serial connectivity module
Real-time clock
Communication expansion
module
Operator panel
80 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers – Technical description
nanoNavigator - Programming made
fast and easy
Compare Move
Compare inputs, outputs, Move values between registers,
program flags and system flags timers, counters and analog
inputs
Decide Message
Decide based on values in Send a message to the Operator
registers, timer, counters or Panel
analog inputs
Control Wait
Control outputs, flags, timers, Wait for a time between
and counters milliseconds to hours
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 81
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
nanoLine® family of controllers – Product overview
Base units
Page 84 84 85 85 85
Page 86 86 86 87
Communication
Serial connection
expansion module
Ethernet USB RS-232 RS-485
Page 88 89 89 89
82 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control Technology
nanoLine® family of controllers – Product overview
Page 90 90 91 91
Page 92 93 93 93 93
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 83
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Base unit
103,5
unit provides connections for a wide variety
of options, including additional I/O,
communications, operator panel and a real
time clock.
The face of the base unit connects to the NLC-050-024D-06I-04QT...
operator panel and has two option slots. Base unit, 24 V DC with 6 digital inputs and 4 NPN outputs
These option slots have connections for a
real-time clock and a serial port module.
The operator panel can be placed directly
into the base, or connected via a remote
mounting kit. The left side of the base Description Type Order No.
Pcs. /
Pkt.
connects to the Ethernet communications
nanoLine controllers, base unit
module, while the right side of the base 6 digital inputs, 4 NPN outputs NLC-050-024D-06I-04QTN-00A 2701030 1
accommodates three expansion I/O 6 digital inputs, 4 PNP outputs NLC-050-024D-06I-04QTP-00A 2701027 1
modules. 6 digital inputs, 4 DC relay outputs
8 digital inputs, 4 AC/DC relay outputs
The nanoLine controllers are configured
and programmed entirely with Cover, replacement
Operator panel NLC-OP1-COVER 2701276 1
nanoNavigator, a free, integrated Cap, replacement
development environment. The Slot 1 NLC-MOD-CAP 2701289 1
configuration and control flow charts Cap, replacement
Slot 2 NLC-MOD-CAP-PXC 2701292 1
download to the base unit via one of the
Technical data NLC-050-024D-06I-04QTN-00A NLC-050-024D-06I-04QTP-00A
serial port options. nanoNavigator can Interfaces
monitor real-time execution, as well as RS-232 Slot 1
simulate the application before USB
Real-Time Clock
Slot 1
Slot 2
downloading. Power supply
Connection supply Screw connection
Supply voltage 24 V DC (Power available to the I/O and Communications modules)
84 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
NLC-050-024D-06I-04QRD-05A 2701043 1
NLC-050-024X-08I-04QRX-05A 2701056 1 NLC-050-100A-08I-04QRA-05A 2701069 1
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 85
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Digital I/O expansion units
103,5
combination, can be added to the right side
of the base unit. Once I/O modules are
connected, they are automatically available
to monitor on the operator panel, via
Modbus TCP/RTU, and for inclusion in flow NLC-IO-06(3)I-04Q...
charts. I/O expansion module, 3 or 6 digital inputs, 4 PNP digital outputs
nanoLine digital I/O modules have
galvanic isolation. They can be powered
from a secondary power supply, enabling
power to be removed from the sensor and
actuators while it is maintained on the Description Type Order No.
Pcs. /
Pkt.
controller.
nanoLine controllers, I/O expansion module
Supported digital options:
– 6 input, 4 PNP transistor output 6 digital inputs, 4 PNP outputs NLC-IO-06I-04QTP-01A 2701072 1
(24 V DC) 6 digital inputs, 4 NPN outputs
3 digital inputs, 4 DC relay outputs
NLC-IO-06I-04QTN-01A
NLC-IO-03I-04QRD-5A
2701085
2701328
1
1
– 6 input, 4 NPN transistor output Technical data NLC-IO-06I-04QTP-01A NLC-IO-03I-04QRD-5A
(24 V DC) Power supply for module electronics
– 3 input, 4 relay outputs (5 A) Supply voltage 24 V DC
Type of connection Screw connection
Supply current Typ. 50 mA Typ. 300 mA
Max. 90 mA Max. 500 mA
Digital inputs
Type of connection Screw connection
Number of inputs 6 3
Description of the inputs PNP/NPN
Typical response time 60 µs (on)
Digital outputs
Type of connection Screw connection
Number of outputs 4
Description of the outputs PNP outputs Relay output
Maximum output current per channel 500 mA 5A
Maximum output current per module / terminal block 2A 20 A
Protective circuitry Short circuit and overload -
protection
General data
Width 40 mm
Height 103.5 mm
Depth 43 mm
Degree of protection IP20
Ambient temperature (operation) -25°C ... 60°C
Ambient temperature (storage/transport) -25°C ... 85°C
86 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Analog I/O expansion module
103,5
combination, can be added to the right side
of the base unit. Once I/O modules are
connected, they are automatically available
to monitor on the operator panel, via
Modbus TCP/RTU, and for inclusion in flow NLC-IO-4AI
charts. I/O expansion module, 4 analog inputs
nanoLine digital I/O modules have
galvanic isolation. They can be powered
from a secondary power supply, enabling
power to be removed from the sensor and
actuators while it is maintained on the Description Type Order No.
Pcs. /
Pkt.
controller.
nanoLine controllers, I/O expansion module
Supported analog options:
– 4 independently configurable analog 4 analog inputs NLC-IO-4AI 2701098 1
inputs Technical data
Power supply for module electronics
Supply voltage 24 V
Supply current 50 mA
Analog inputs
Type of connection 2-wire
Connection method Screw connection
Number of inputs 4
Description of the inputs single ended
Voltage input signal 0 V ... 10 V
Current input signal 4 mA ... 20 mA
Basic error limit 1%
Measured value resolution 12 bits
General data
Width 40 mm
Height 103.5 mm
Depth 43 mm
Degree of protection IP20
Ambient temperature (operation) -25°C ... 60°C
Ambient temperature (storage/transport) -25°C ... 85°C
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 87
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Communication expansion module
Ethernet connectivity
The nanoLine family supports a new level
of connectivity in its product class. This
connectivity enables customers to embed
the nanoLine into systems, monitor these
systems at a distance, or remotely control
the nanoLine system.
With the installation of the Ethernet
expansion module, the nanoLine control
can function as a Modbus TCP Server. This NLC-COM-ENET-MB1
enables all I/O points, registers, timers, Ethernet Communication Expansion Module, 10/100 Mbps,
counters, program flags and system flags to Autonegotiation, Modbus TCP Server
88 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Serial connection modules
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 89
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Flexible operator panel
Keys 11
Height 31.5 mm
Width 76 mm
Depth 46 mm
Degree of protection IP67/IP20
Ambient temperature (operation) 0°C ... 50°C
Ambient temperature (storage/transport) 0°C ... 60°C
OK
15
14
13
12
11
M 10
CO
Line
no
na
90 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
Real-time clock
Memory module
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 91
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
nanoNavigator
developed, simulated, and perfected Move - Move values between registers, timers, counters and analog
without any hardware. inputs
Message - Send a message to the operator panel
Languages supported
German, English
92 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
nanoLine® family of controllers
nanoLine starter kits
NLC-START-01 2701399 1
Starter kit, consisting of:
- Base unit with 6 digital inputs and 4 PNP digital outputs
- Operator panel
- USB serial module and USB cable
- nanoNavigator software
- Input and output simulators
NLC-START-02 2701425 1
Starter kit, consisting of:
- Base unit with 6 digital inputs and 4 relay outputs
- Operator panel
- USB serial module and USB cable
- nanoNavigator software
- Input and output simulators
NLC-START-03 2701467 1
Deluxe starter kit, consisting of:
- Base unit with 6 digital inputs and 4 PNP digital outputs
- Operator panel
- USB serial module and USB cable
- nanoNavigator software
- Input and output simulators
- PNP digital expansion I/O module
- Ethernet module
- Step Power Supply
NLC-START-04 2701483 1
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 93
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
94 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Automation system of the 100 series performance class
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 95
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Automation system of the 100 series performance class – Technical description
Smart automation with the Cost-effective controllers for smart Operation and monitoring for your
automation system of the automation automation solution
100 series class
Our cost-effective compact controllers The graphical interface forms the
are the key elements of the system. All business card of an automated application
controllers of the 100 series class of and gives you an overview of all processes.
Phoenix Contact come with eight digital Our wide range of devices for operation
inputs and four digital outputs. By simply and monitoring facilitates the cost-effective
mounting Inline I/O modules, more digital integration of an attractive yet affordable
and analog input and output modules can be user interface in your solution.
added as usual to compact controllers as Each controller is equipped with an
well. integrated web server. Using WebVisit, you
Thanks to an extensive range of can add your visualization application to the
I/O functions, all industry-relevant sensors pages of this web server and implement
and actuators can be integrated in the your visualization in a cost-effective way.
system. You can also reduce the The visualization pages required for
configuration and startup times with our operating your machine or system are
ILC 130 STARTER KIT. simply stored in the file system of the
controller.
With a standard browser, every PC can
Free software for smart automation be used for machine and system monitoring
With our automation system built or for remote control. And our cost-
PC Worx Express is a user-friendly
around the compact control systems of the software that facilitates your entry into effective graphic panels with touch-control
100 series class, we enable an economical and an integrated browser (WebPanel)
IEC 61131 programming – even without
and easy entry into automation. directly operate the machine with their
in-depth programming knowledge.
This enables automatic control of simple The programs can be drawn up as ladder detailed and brilliant display.
processes in a cost-effective manner and
diagrams using easy-to-understand symbols
economical automation of small systems as
within no time. Should you require a special
well. Naturally, devices of the 100 series input function, for example position
performance class also support all
detection by an encoder for your
communication paths possible via Ethernet
application, a function block provided
in addition to the control function. with the software immediately gives you
Web-based visualizations, which can be
the position value.
easily and cost-effectively presented on a
PC or a small web panel, are thus available
for price-sensitive applications.
Since the controller can be expanded
with a multitude of Inline I/O modules and
connected to devices for operation and
monitoring as well as infrastructure
components, the 100 series performance
class offers a flexible solution for your
application. WP 04T HMI
Switch PLC IO
Programming
96 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Automation system of the 100 series performance class – Technical description
cl
em
undertake all communication tasks for page gives you an overview of all products
which Ethernet is now widely used and that can be perfectly integrated in the
preferred in industrial applications. 100% in automation system of the 100 series
An FTP server thus enables exchange of te g r a ted control class. Our comprehensive
inte
files with any data and the open TCP/IP or interoperability tests guarantee smooth
UDP/IP blocks further round off the functioning.
Ethernet and IT compatibility. Regardless of
ed
ro
pe
whether the controller sends e-mails, loads
rab st
a new application program from a central ility te
server, logs data in realtime, or reads and
writes databases – all functions can be
performed quickly and easily.
Our solutions make use of technologies from the IT field in order to avoid technology barriers and to ensure sustainability of the
automation solution. In addition to the Windows operating system, standard Ethernet protocols have also been used successfully.
As a manufacturer, we ensure that your investments are safeguarded and that it is possible to adapt your system to new
developments even in the future.
Compact controllers from Phoenix Contact offer various IT-powered features via the Ethernet interface:
OPC: The OPC server provides data from the PLC program for visualization programs such as VISU+, or transports
the data in the opposite direction. The OPC server runs in the control panel or on a PC.
Web server: Provides a homepage on controllers. Its pages can be designed using the WEBVISIT software and linked to the
PLC program via data. Browsers can display these pages via HTTP access.
TCP/IP: Makes it possible to establish connections between the PLC program and programs on other Ethernet devices.
Function blocks such as IP-Connect, IP-send, etc., are available to the PLC programmer for this.
UDP: Wireless messages can be received/sent from/to other Ethernet devices in the PLC program with UDP. This is
done with the same function blocks as in case of TCP/IP.
FTP: Controllers are equipped with an FTP server. Hence, any file can be stored in or uploaded to the Flash file
system of the controller, for example for exchanging parameterization and log files or for storing the current
source code of the PLC program for servicing.
SNTP: To synchronize the realtime clock of the controller with a time server.
SQL: For data exchange between the PLC program and an MS-SQL-/mySQL database
(special PC WORX block library).
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 97
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Automation system of the 100 series performance class – Product overview
Type ILC 130 ETH ILC 150 ETH ILC 155 ETH ILC 150 GSM/GPRS ILC 170 ETH 2TX
Order No. 2988803 2985330 2988188 2916545 2916532
Description Entry level model, Standard controller Controller with Controller with Controller with 2x Ethernet and
without the remote bus option of the 100 series class integrated block license GSM/GPRS modem pluggable memory
Page 24 24 25 25 25
Type PC WORX EXPRESS PROJECT+ RESY-DATA-A LIC AX OPC-SERVER ILC 130 STARTER KIT
Order No. 2988670 2988667 2876847 2985945 2988515
Type PC WORX PRO LIC WEBVISIT BASIC
Order No. 2985385 2985990
Type VISU+
Order No. 2985770
Description Programming as per IEC 61131 Configuring I/Os Remote control Visualization Pre-assembled test structure
Page 43 40 49 53 26
Type WP 04T TP 10T TP 12T/M 201 FL COM Server RS232 PSI modem/ETH
Order No. 2913632 2985181 2913250 2744490 2313300
Type WP 06T TP 15T PSI-GPRS/GSM modem/RS232-QB
Order No. 2913645 2985204 2313106
Description Web panel Touch panel Touch panel, 12" display Connection via mobile phone Connection via telephone line
4"/6" display 10"/15" display Maritime approval network
Type FL SWITCH SFN 5TX FL SWITCH LM 8TX FL SWITCH SMCS 8GT FL SWITCH MCS 16TX ...-CABLE-...
Order No. 2891152 2832632 2891123 2832700 ...
Type FL SWITCH SFN 8TX FL SWITCH SMCS 6GT/2SFP FL SWITCH MM HS ...
Order No. 2891929 2891479 2832328
Description Standard switches Lean managed switch Gigabit switches Managed switches You will find suitable cables and
connectors in our online catalog
98 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Automation system of the 100 series performance class – Product overview
Digital input
1 channel 2 channels 4 channels 8 channels 16 channels 32 channels
IB IL 120 DI 1-PAC IB IL 24 DI 2-PAC * IB IL 24 DI 4-PAC IB IL 24 DI 8-PAC * IB IL 24 DI 16-PAC * IB IL 24 DI 32/HD-PAC
2861917 2861221 2861234 2861247 2861250 2862835
IB IL 230 DI 1-PAC IB IL 24 DI 2-NPN-PAC IB IL 24 DI 4-ME IB IL 24 DI 8/T2-PAC IB IL 24 DI 16-NPN-PAC IB IL 24 DI 32/HD-NPN-PAC
2861548 2861483 2863928 2862204 2863520 2878243
IB IL 24 EDI 2-PAC IB IL 24 DI 16-ME
2861629 2897156
Digital output
1 channel 2 channels 4 channels 84 channels 16 channels 32 channels
IB IL DO 1 AC-PAC IB IL 24 DO 2-PAC * IB IL 24 DO 4-PAC * IB IL 24 DO 8-PAC * IB IL 24 DO 16-PAC * IB IL 24 DO 32/HD-PAC
2861920 2861276 2861276 2861289 2861292 2862822
IB IL 24/230 DOR1/W-PAC * IB IL 24 DO 2-2A-PAC IB IL 24 DO 4-ME IB IL 24 DO 8-2A-PAC IB IL 24 DO 16-ME IB IL 24 DO 32/HD-NPN-PAC
2861881 2861263 2863931 2861603 2897253 2878340
IB IL 24/230 DOR1/W-PC-PAC IB IL 24 DO 2-NPN-PAC IB IL DO 4-AC-1A-PAC IB IL 24 DO 8-NPN-PAC
2862178 2861496 2861658 2863546
IB IL 24 EDO 2-PAC IB IL 24/230 DOR4/W-PAC *
2861616 2861878
IB IL 24/48 DOR 2/W-PAC IB IL 24/230 DOR4/W-PC-PAC
2863119 2862181
IB IL 24/230 DOR4/HC-PAC
2897716
Temperature recording
1 channel 2 channels 4/8 channels 4 channels 6 channels 8 channels
IB IL 24 TC-PAC * IB IL TEMP 2 RTD-PAC IB IL TEMP 4/8 RTD/EF-PAC *
2861360 2861328 2897402 IB IL TEMP 4 UTH HEI 1 IB IL TEMP 6 RTD HEI 1 IB IL TEMP 8 UTH HEI 1
DO4-PAC * DO 6-PAC * DO8-PAC *
IB IL TEMP 4/8 RTDPAC * 2819707 2819684 2819697
2863915
IB IL SGI 2/F-PAC IB IL RS 232-PAC IB IL INC-IN-PAC IB IL PWM/2-PAC IB IL 400 ELR 1-3A * IB IL 24 SAFE 1-PAC
2878638 2861357 2861755 2861632 2727352 2861564
IB IL SGI 2/P-PAC IB IL RS 232-PRO-PAC IB IL SSI-IN-PAC IB IL CNT-PAC IB IL 400 MLR 1-8A *
2884907 2878722 2819574 2861852 2727365
IB IL 400 ELR R-3A *
2727378
8 channels 16 channels 4(8)/4 channels 8/8 channels 16/16 channels 4 channels 8 channels
* These terminals/modules are also available for the fast INTERBUS variant with a transmission speed of 2 MBd.
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 99
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
100 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Safety
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 101
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety – Technical description
Safe system solutions with Open safety system for all INTERBUS Safety – High-
INTERBUS Safety and PROFIsafe applications performance control technology
The demand for cost-cutting As machine and system engineers, you Integration of the INTERBUS Safety
applications and increased flexibility is require in-depth knowledge about the system into the PC Worx automation
growing fast and that includes safety components and systems used in order to software simplifies the project-related
applications. With INTERBUS Safety and be able to fulfill the requirements put forth programming of the relevant PROFINET
PROFIsafe, machine and system engineers by the current changes in the standards and controller.
have two systems dedicated to these and regulations as well as the requirements of
The PROFINET Proxy and INTERBUS
other requirements. The main feature of the new machine directive.
Master with an integrated safe controller,
the system is its simplicity: In order to be The PROFIsafe application I/O for instance, act as a link between the safe
able to transmit safe and standard data via a
components (PSDI 8-PAC, PSDO 8-PAC, and the non-safe applications. The safe and
bus cable, the safety protocol is exchanged
PSDOR 4-PAC, PSDO 4/4-PAC) in standard components are uniformly
between the safe controller and the safe I/O INTERBUS Safety as well as PROFIsafe integrated into the turn-key solution by
components. Here, the safety information
systems (PROFINET and PROFIBUS) are universal engineering.
along with its independent safety
only one point that supports you during the Easy project planning of the system,
mechanisms is embedded in the standard implementation of the new requirements of
data transmission of the relevant bus uniform diagnostics and intuitive
your safety applications.
system and unpacked only in the safe I/O programming using PC Worx and
module. A well-developed control system and SafetyProg simplify the handling and
software range, as well as a comprehensive minimize the creation period.
Short startup times, high availability and
training and qualification offer support you
maximum safety complete the scope of during the implementation of current
service.
projects as well as in the training of your
personnel involved in safety projects.
Simple integration
IPC PROFIsafe Control system Inline
controller bus couplers
INTERBUS Safety
or IB IL 24 PS...
Safe
I/O component IP20
I/O component
IP67
Electrosensitive Enable switch
protective equipment
The safe PROFIsafe modules can be The safe controller in the PROFINET or Sensors and actuators are conveniently
integrated anywhere on the Inline station, PROFIBUS network is connected with an integrated in the respective safe bus system
whereby mixed operation of standard and appropriate bus coupler. In addition to the via the inputs and outputs of the PROFIsafe
safety terminals is possible. INTERBUS-Safety functions, the modules modules. The settings can be parameterized
can also be used in the PROFIsafe systems flexibly for single or two-channel I/O wiring
via the address switches. as well as for diagnostics.
102 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety – Technical description
Communication between the safe In order to be able to transmit safe and If the emergency stop button is
controller and the safe devices takes place standard data via a bus line, the PROFIsafe actuated, the safety controller switches off
via the INTERBUS Safety protocol. protocol is exchanged between the safe the output via the safe output module. Only
The safe protocol data is integrated into controller and the safe I/O components via when all input conditions have been met
the data flow of the standard INTERBUS a "black channel". Here, the safety telegrams again does the safe controller allow the
system just like normal device data. The with their independent safety mechanisms output to be switched on via the standard
integrated safety protocol can only be are embedded in a standard telegram of the controller.
evaluated by the safe components. PROFINET system and are only extracted in
the respective safety terminal.
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 103
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety – Product overview
Type SAFETY SLC 400 PND-4TX-IB ILC 350 PN IB-SAFETY KIT ILC 370 PN IB-SAFETY KIT ILC 390 PN IB-SAFETY KIT
Order No. 2985563 2916451 2916561 2916671
Description PROFINET proxy and INTERBUS System package, System package, System package,
master with integrated safe contains the following orders: contains the following orders: contains the following orders:
controller ILC 350 PN (Order No. 2876928) ILC 370 PN (Order No. 2876915) ILC 390 PN (Order No. 2985314)
SAFETY SLC 400 PND-4TX-IB SAFETY SLC 400 PND-4TX-IB SAFETY SLC 400 PND-4TX-IB
(Order No.2985563) (Order No. 2985563) (Order No. 2985563)
Safety digital
Safety digital input terminals
input/output modules
Type IB IL 24 SDI 8-PAC IB IL 24 PSDI 8-PAC IBS RL 24 SDIO 4/4/8-LK IB IL 24 SDIO 4/4/1
Order No. 2985657 2985688 2737520 2863740
Description 8 safety 8 safety 8 safety 8 safety
digital inputs for the digital inputs for the digital inputs, 6 safety digital outputs digital inputs, 6 safety digital outputs,
INTERBUS Safety system INTERBUS Safety and PROFIsafe for the 1 safety relay output for the
system INTERBUS Safety system INTERBUS Safety system
Type IB IL 24 SDO 8-PAC IB IL 24 PSDO 8-PAC IB IL 24 SDOR 4-PAC IB IL 24 PSDOR 4-PAC IB IL 24 PSDO 4/4-PAC
Order No. 2985754 2985631 2985851 2985864 2916493
Description 8 safety 8 safety 4 safety 4 safety 4 safety
digital outputs for the INTERBUS digital outputs for the INTERBUS relay outputs for the relay outputs for the digital +/- switching outputs
Safety system Safety and PROFIsafe system INTERBUS Safety system INTERBUS Safety and PROFIsafe for the INTERBUS Safety and
system PROFIsafe system
104 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety – Product overview
Bus coupler
INTERBUS Safety –
Safety programming
Page 111
Type SAFETYPROG2.X PLCOPEN SAFETYPROG2.X PLCOPEN SAFETYPROG2.X PLCOPEN SAFETYPROG2.X PLCOPEN SAFETYPROG2.X PLCOPEN
BASIC OSSD TWOHAND MUTING SAFEMODE
Order No. 2876067 2916859 2916846 2916862 2916875
Description BASIC_SF OSSD TwoHand Muting SafeMode
– SF_EmergencyStop – SF_Espe – SF_TwoHandControl TypII – SF_MutingPar_2Sensor – SF_ModeSelector
– SF_GuardMonitoring – SF_TestableSafetySensor – SF_TwoHandControl TypIII – SF_MutingSeq – SF-SafetyRequest
– SF_GuardLocking – SF_MutingPar – SF_EnableSwitch
– SF_EDM
– SF_OutControl
– SF_Equivalent
– SF_Antivalent
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 105
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
Fail-safe digital input/output
terminals
outputs.
- for INTERBUS Safety
- for INTERBUS Safety and PROFIsafe
Fail-safe relay output module
Technical data
Local bus interface
Fieldbus system INTERBUS
Type of connection Inline data jumper
Transmission rate 500 kBaud/ 2 MBaud, switchable
Power supply for module electronics
Supply voltage 24 V DC (via voltage jumper)
Range of supply voltages 19.2 V DC ... 30 V DC
Digital inputs
Connection method 2, 3, 4-wire
Number of inputs 8
Digital outputs
Connection method -
Number of outputs -
Description of the outputs -
Maximum output current per channel -
Protective circuitry -
General data
Weight 200 g
Width 48.8 mm
Ambient temperature (operation) -25°C ... 55°C
106 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
T
Applied for: UL / CUL T T
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
- - -
- - -
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 107
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
Fail-safe digital input/output modules
uT uT
Pcs. / Pcs. /
Description Type Order No. Type Order No.
Pkt. Pkt.
Digital input/output module, IP67 degree of protection
4 fail-safe digital inputs, 4 fail-safe digital outputs IBS RL 24 SDIO 4/4/8-LK 2737520 1
4 fail-safe digital inputs, 4 fail-safe digital outputs, 1 fail-safe relay IB IL 24 SDIO 4/4/1 2863740 1
output or 1 fail-safe output for the segment circuit
Technical data
Interface
Fieldbus system INTERBUS -
Name Remote bus -
Type of connection Optic fiber (polymer fiber 980/1000 µm) -
Local bus interface
Fieldbus system - INTERBUS
Type of connection - Inline data jumper
Power supply for module electronics
Supply voltage 24 V 24 V DC (via voltage jumper)
Range of supply voltages 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC
Digital inputs
Connection method M12 connector 2, 3, 4-wire
Number of inputs 8 8
Name of protection Short circuit and overload protection -
Digital outputs
Connection method M12 connector 2, 3, 4-wire
Number of outputs 6 8
Maximum output current per channel 1A 1A
Protective circuitry Overload protection, short circuit protection of outputs Overload protection, short circuit protection of outputs
General data
Weight 1600 g 1380 g
Width - 183.5 mm
Height - 120 mm
Depth - 72 mm
Ambient temperature (operation) 0°C ... 55°C -25°C ... 55°C
108 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
Safety controller
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 109
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
System packages
110 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Safety
SafetyProg – Programming tool for
safety components
INTERBUS Safety
Easy programming of safety-oriented
networks
The faster the project planning,
programming and startup and the more
detailed the display of the diagnostics
information, the higher the machine or
system availability. For this reason, we have
developed a software solution with
SafetyProg that will support you with a large SAFETYPROG 2...
number of user-friendly functions, easy Programming software for INTERBUS Safety systems
handling and clear structuring when
installing your safe application.
The safe interface is supplemented with
the software tools of the T
AUTOMATIONWORX software suite. Description Type Order No.
Pcs. /
Pkt.
Programming software for INTERBUS safety systems, with SAFETYPROG 2 PRO 2985835 1
INTERBUS Safety graphical interface in acc. with IEC 61131-3 in the languages
- Function block diagram (FBD)
Safe PLCopen function blocks for - Ladder diagram (LD)
SafetyProg Software library system, function blocks for diagnostics and SAFETYPROG 2.X SYSTEM 2985741 1
Use of the PLCopen function block handling of the INTERBUS Safety system
library considerably simplifies the Basic software library, function blocks for basic functions of the SAFETYPROG 2.X BASIC 2876038 1
implementation of your safety functions in INTERBUS Safety system
the INTERBUS Safety system. Safety PLCopen Basic software library, PLCopen-compliant function SAFETYPROG2.X PLCOPEN BASIC 2876067 1
functions can be planned and programmed block library to support the basic functionalities of the safety
quickly and safely with the help of the technology
standardized and certified blocks. The PLCopen TwoHand software library, PLCopen-compliant SAFETYPROG2.X PLCOPEN 2916846 1
validation of your application becomes function block library that supports two-hand application in the
safety technology
TWOHAND
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 111
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
112 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology | Network interfaces
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 113
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces – Technical description
XXX xx xx xx xx
xx xx xx xx
XXX xxx
xxx xxx xxx
XX xx xx xx
XXX
xx xxx xxx xxx
xx xx xx
114 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces – Technical description
PC driver
In a PC environment, the driver is the OPC client HFI application
interface that the programmer sees.
Integration in its control system solution
must be very easily possible. All important HFI
drivers are compatible with the Windows
environment. The input and output signals INTERBUS OPC server
are presented via linear address areas.
Mailboxes are available for communication
with the modules.
If the operating system is not supported,
the driver can be moved to a separate Drivers for I/O access via PC interfaces
platform with the help of a device driver
development kit (DDK).
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 115
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces – Product overview
Type IBS S5 DSC/I-T IBS S7 300 BC-T IBS S7 300 DSC-T IBS S7 400 DSC/I-T IBS S7 400 ETH DSC/I-T
Order No. 2752000 2721947 2719975 2719962 2731102
Interface type SIMATIC® S5 master SIMATIC® S7-300 master SIMATIC® S7-300 master SIMATIC® S7-400 master SIMATIC® S7-400 master
PC controller boards
PCI
Type IBS PCI SC/I-T IBS PCI RI/I-T IBS PCI RI-LK IBS PCI SC/RI/I-T IBS PCI SC/RI-LK
Order No. 2725260 2730129 2704045 2730080 2730187
Interface type PCI master PCI slave PCI slave PCI system coupler PCI system coupler
Type IBS PCI 104 SC-T IBS PC 104 SC-T IBS PC ISA SC/I-T
Order No. 2737494 2721701 2719234
Interface type PCI/104 master PC/104 master ISA master
116 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces – Product overview
Ethernet
Type FL IBS SC/I-T FL NP PND-4TX IB FL NP PND-4TX IB-LK FLM BK ETH M12 DI 8 M12-2TX
Order No. 2831060 2985974 2985929 2736916
Interface type Ethernet gateway PROFINET proxy and PROFINET proxy and Fieldline Modular bus coupler
Ethernet gateway Ethernet gateway
Ethernet
Type FL IL 24 BK-B FL IL 24 BK-B-PAC IL ETH BK DI8 DO4 2TX-PAC ILB ETH 24 DI16 DIO16-2TX
Order No. 2862314 2862327 2703981 2832962
Interface type Ethernet bus terminal Ethernet bus terminal Ethernet bus terminal Ethernet IO
Software Accessories
Type IBS CMD SWT G4 CONFIG+ IBS DIAG+ SWT DIAG+ NETSCAN ...-CABLE-...
Order No. 2721439 2868059 2730307 2868075 ...
Type IBS CMD SWT G4 E ...
Order No. 2721442
Interface type Configuration and diagnostics Network configuration software Diagnostic software Diagnostic software You can find the suitable cables and
software connectors in our online catalog
Page 45 47 57 57 www.phoenixcontact.net/catalog
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 117
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
Master controller boards for
SIMATIC® S7-300/400-based control
solutions
You do your programming in the Step7®
environment. Well-developed blocks enable
easy data exchange and the integration of
excellent diagnostic features in the
application program. The addressing and
configuration of the controller board is
performed via CMD/Config+.
With up to 8192 I/O points per bus
system, the system can be extended almost
infinitely. IBS S7 300 BC-T
In the case of S7 400, one version with a Controller board for Siemens SIMATIC® S7-300 controllers,
built-in Ethernet interface allows direct Without diagnostics display
tasks, a Step 7® module library is available - German IBS S7 300 B SYSKIT 2721921 1
on the software library CD "CD AX - English IBS S7 300 B SYSKIT E 2721934 1
Controller board for Siemens SIMATIC® controllers
SOFTWARE LIB". More information is
provided in the e-shop under - S7-300 IBS S7 300 BC-T 2721947 1
www.phoenixcontact.net/eshop. - S7-400
Driver and documentation CD
CD IBS S7 300 400 2704032 1
IBS-CMD software, for configuration, diagnostics, German
CONFIG+ 2868059 1
Diag+ full version, for INTERBUS diagnostics (ActiveX Control
with programming interface)
IBS DIAG+ SWT 2730307 1
Programming cable, to connect the controller boards to the PC
(RS-232-C), length 3 m
IBS PRG CAB 2806862 1
Program and configuration memory
- 2 MB
Technical data
Interfaces
Control system SIMATIC® S7-300 I/O bus
INTERBUS remote bus 9-pos. D-SUB female connector
Ethernet -
Parameterization/operation/diagnostics RS-232-C, D-SUB male connector
INTERBUS master
Number of possible parameter channels -
Number of I/O nodes 1920
Number of supported devices 128
118 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
IBS S7 300 DSC-T IBS S7 400 DSC/I-T IBS S7 400 ETH DSC/I-T
Controller board for Siemens SIMATIC® S7-300 controllers Controller board for Siemens SIMATIC® S7-400 controllers Controller board for Siemens SIMATIC® S7-400 controllers,
with Ethernet port
uP uP uP
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
IBS S7 300 SYSKIT 2721303 1 IBS S7 400 SYSKIT 2721374 1 IBS S7 400 ETH SYSKIT 2740067 1
IBS S7 300 SYSKIT E 2721316 1 IBS S7 400 SYSKIT E 2721361 1 IBS S7 400 ETH SYSKIT E 2740070 1
CD IBS S7 300 400 2704032 1 CD IBS S7 300 400 2704032 1 CD IBS S7 300 400 2704032 1
IBS CMD SWT G4 2721439 1 IBS CMD SWT G4 2721439 1 IBS CMD SWT G4 2721439 1
IBS CMD SWT G4 E 2721442 1 IBS CMD SWT G4 E 2721442 1 IBS CMD SWT G4 E 2721442 1
IBS DIAG+ SWT 2730307 1 IBS DIAG+ SWT 2730307 1 IBS DIAG+ SWT 2730307 1
IBS PRG CAB 2806862 1 IBS PRG CAB 2806862 1 IBS PRG CAB 2806862 1
IBS MC FLASH 2MB 2729389 1 IBS MC FLASH 2MB 2729389 1 IBS MC FLASH 2MB 2729389 1
SIMATIC® S7-300 I/O bus SIMATIC® S7-400 P bus SIMATIC® S7-400 P bus
9-pos. D-SUB female connector 9-pos. D-SUB female connector 9-pos. D-SUB female connector
- - 10/100Base-T via RJ45
RS-232-C, D-SUB male connector RS-232-C, D-SUB male connector RS-232-C, D-SUB male connector
External power supply Via SIMATIC I/O bus Via SIMATIC I/O bus
24 V DC 5 V DC 5 V DC
- 0.9 A 2.5 A
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 119
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
Factory Line I/O server
INTERBUS connection
gateway supports the full duplex mode with Description Type Order No.
Pcs. /
Pkt.
100 Mbps. The INTERBUS system opens up
INTERBUS Ethernet gateway
advantages for installation, startup and FL IBS SC/I-T 2831060 1
maintenance, since INTERBUS devices do CD-ROM, with user documentation in PDF format, driver software
not require any time-consuming address and sample programs
CD FL IBS SC 2832056 1
settings. Only the gateway requires a Factory Manager, multilingual configuration and diagnostics
network-specific IP address. Using Web software for ETHERNET networks in automation
find technical data, connection diagrams and IBS-CMD software, for configuration, diagnostics, English IBS CMD SWT G4 E 2721442 1
further information on our web site. You Programming cable PRG CAB MINI DIN 2730611 1
can also make configuration settings or Technical data
changes conveniently and easily. Password Ethernet interface
protection is of course provided. Interface Ethernet
Type of connection 1 port 10/100Base-T(X), autonegotiation
The universally applicable Device Driver INTERBUS interface
Interface (DDI) is available as a software INTERBUS master interface 9-pos. D-SUB female connector
interface for access via TCP/IP. Other connections
Diagnostics INTERBUS 6-pos. MINI-DIN female connector
Furthermore, data can be exchanged with Power supply
the INTERBUS-OPC server using the OPC Supply voltage 24 V DC (via COMBICON; max. conductor cross section 2.5 mm2)
standard. As OPC clients, the visualization Residual ripple 3.6 VPP (within the permitted voltage range)
and SCADA tools can use the flexible
access to I/O data via the network. Range of supply voltages
Typical current consumption
18.5 V DC ... 30.2 V DC
200 mA (to US)
Weight 240 g
Width 45 mm
Height 99 mm
Depth 117 mm
Ambient temperature (operation) 0°C ... 55°C
Ambient temperature (storage/transport) -20°C ... 70°C
120 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
Slave controller board for the PCI bus
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 121
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
Master controller boards for PCI and
ISA bus
Direct inputs/outputs
Number of inputs 6
Number of outputs 2
Software interfaces
Software driver Windows NT / Windows 2000 / Windows XP / Venturcom RTX 5.x /
Further types on request
Application interface HFI
OPC
DDI
Power supply
Connection supply Via PCI bus
Supply voltage 5 V DC
Range of supply voltages ± 5% (including ripple)
Typical current consumption 0.7 A
General data
Weight 150 g
Format Short plug-in card, 1-slot
Ambient temperature (operation) 0°C ... 55°C (in acc. with EN 60204-1)
Ambient temperature (storage/transport) -25°C ... 75°C (in acc. with EN 60204-1)
122 PHOENIX CONTACT Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108.
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com
Control technology
Network interfaces
IBS PC ISA SC/I-T IBS PCI 104 SC-T IBS PC 104 SC-T
PC controller board in ISA format Termination board in PCI-104 format Controller board in PC/104 format
uP u uP
Pcs. / Pcs. / Pcs. /
Type Order No. Type Order No. Type Order No.
Pkt. Pkt. Pkt.
IBS PC ISA SC/I-T 2719234 1 IBS PCI 104 SC-T 2737494 1 IBS PC 104 SC-T 2721701 1
IBS CMD SWT G4 2721439 1 IBS CMD SWT G4 2721439 1 IBS CMD SWT G4 2721439 1
IBS CMD SWT G4 E 2721442 1 IBS CMD SWT G4 E 2721442 1 IBS CMD SWT G4 E 2721442 1
IBS DIAG+ SWT 2730307 1 IBS DIAG+ SWT 2730307 1 IBS DIAG+ SWT 2730307 1
IBS OPC SERVER 2729127 1 IBS OPC SERVER 2729127 1 IBS OPC SERVER 2729127 1
IBS PRG CAB 2806862 1 IBS PRG CAB 2806862 1 IBS PRG CAB 2806862 1
IBS PC 104 SC CAB 2724436 1 IBS PC 104 SC CAB 2724436 1
RS-232-C, D-SUB 9-pos. male connector RS-232-C, 10-pos. DIL male connector RS-232-C, 10-pos. DIL male connector
- - -
- - -
- - -
Windows NT / Windows 2000 / Windows 95/98 / DOS / Windows NT / Windows 2000 / Windows XP / Venturcom RTX 5.x / Windows NT / Windows 2000 / Windows 95/98 / DOS /
Further types on request Further types on request Further types on request
OPC HFI OPC
DDI OPC DDI
DDI
140 g 80 g 80 g
Short plug-in card, 1-slot PCI-104 PC/104
-25°C ... 75°C (in acc. with EN 60204-1) 0°C ... 55°C (in acc. with EN 60204-1) 0°C ... 55°C (in acc. with EN 60204-1)
0°C ... 75°C (in acc. with EN 60204-1) -25°C ... 75°C (in acc. with EN 60204-1) -25°C ... 75°C (in acc. with EN 60204-1)
Coutesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. PHOENIX CONTACT 123
Main Office: (800) 843-9859 - www.powermation.com - info@powermation.com