Sigma Dur 188 Technical Data Sheet
Sigma Dur 188 Technical Data Sheet
Sigma Dur 188 Technical Data Sheet
SIGMADUR 188
4 pages November 2005
Revision of September 2003
COLOURS AND GLOSS white and black, colors available on request - gloss
BASIC DATA AT 20℃ (1 g/cm³ = 8.25 lb/US gal; 1 m²/l = 40.7 ft²/US gal)
(data for mixed product)
Mass density approx.1.2 g/cm³
Solids content 56 ±2%
VOC 3.3 lb/us gal – 398 g/L
Recommended dry film 50-60 µm depending on system
Thickness
2
Theoretical spreading rate 11.2 m /l for 50µm*
Touch dry after 1 hours
Overcoating interval min. 6 hours*
max. unlimited
Full cure after 4 days*
RECOMMENDED - previous coat; (epoxy or polyurethane) dry and free from any contamination and
SUBSTRATE CONDITIONS sufficiently roughened if necessary
o
AND TEMPERATURES - during application and curing, a substrate temperature down to -5 C is acceptable
provided the substrate is free from water or ice
o
- substrate temperature should be at least 3 C above dew point
- maximum relative humidity during application and curing is 85%
- premature exposure to early condensation and rain may cause color and gloss
change
Page 1 / 4
DATA
SIGMADUR 188
November 2005
INSTRUCTION FOR USE mixing ratio 88:12 by volume
– the temperature of the mixed base & hardener should be above 10°C, otherwise
extra solvent may be required to obtain application viscosity
– too much solvent will result in lower sag resistance and slower cure
– Sigma thinner should be added after mixing of the components
APPLICATION METHODS High gloss thin film polyurethane finishes tend to atomise less easy. The widely used
airless spray application method is for those kinds of finishes possible but not be the
best option as small nozzles and high pressures can easily result in overspray.
Better suitable methods are pressure pot and air assisted airless (e.g. airmix)
application which result in better dry film thickness control, better appearance and
much less overspray.
AIRLESS SPRAY
Recommended thinner Sigma thinner 21-06
Volume of thinner 8-15%,depending on required film thickness and application conditions
Nozzle orifice 0.28-0.33mm(0.011-0.013inch)
Nozzle pressure 20MPa(approx. 200bar or 2800psi)
AIR SPRAY
Recommended thinner Sigma thinner 21-06
Volume of thinner 5-10%, depending on required film thickness and application conditions
Nozzle orifice 1-1.5 mm
Nozzle pressure 0.3-0.4 Mpa (approx.3-4bar or 40-60psi)
ROLLER/BRUSH
Recommended thinner Sigma thinner 21-06
Volume of thinner 5-10%
SAFETY PRECAUTION for paint and recommended thinners see satety sheets 1430,1431 and relevant
material safety data sheets
this is a solvent based paint and care should be taken to avoid inhalation of spray
and mist or vapour as well as contact between the wet paint and exposed skin or
eyes
Page 2 / 4
DATA
SIGMADUR 188
November 2005
– contains a toxic polyisocyanate curing agent
– avoid at all times, inhalation of aerosol spraymist
Curing table
o
substrate temp C dry to handle full cure
o
-5 C 24 hours 15 days
o
0C 16 hours 11 days
o
10 C 8 hours 6 days
o
20 C 6 hours 4 days
o
30 C 5 hours 3 days
o
40 C 3 hours 2 days
– adequate ventilation must be maintained during application and curing
(please refer to sheet 1433 and 1434)
- premature exposure to early condensation and rain may cause color and gloss
change
Worldwide availability Whist it is always the aim of Sigma Coatings to supply the same product on a
worldwide basis, slight modification of the product is sometimes necessary to
comply with local or national rules/circumstances.
Under these circumstance an alternative product data sheet is used.
Page 3 / 4
DATA
SIGMADUR 188
November 2005
Limitation of Liability
The information in this data sheet is based upon laboratory tests we believe to be accurate and is intended for
guidance only. All recommendations or suggestions relating to the use of the products made by Sigma
Coatings, whether in technical documentation, or in response to a specific enquiry, or otherwise, are based on
data which to the best of our knowledge are reliable. The products and information are designed for users
having the requisite knowledge and industrial skills and it is the end-user’s responsibility to determine the
suitability of the product for its intended use.
Sigma Coatings has no control over either the quality or condition of the substrate, or the many factors
affecting the use and application of the product. Sigma Coatings does therefore not accept any liability arising
from loss, injury or damage resulting from such use or the contents of this data sheet (unless there are written
agreements stating otherwise).
The data contained herein are liable to modification as a result of practical experience and continuous product
development. This data sheet replaces and annuls all previous issues and it is therefore the user’s
responsibility to ensure that this sheet is current prior to using the product.
The English text of this document shall prevail over any translation thereof.
DS 6824