INSTALLATION
SECTION Q
PLUMBING AND MECHANICAL
ENGINEERING INSTALLATIONS
Measurement Rules
Section Q
4. Brasswork
Air release valve, Gate valve, Check valve, Strainer valve, Flexible
joint
5. Portable Fire Extinguisher
6. Equipment and Ancillaries
Concrete plinth
7. Pipe Support
Pipe hanger
8. Sundries
Testing
Fire Fighting Installation
MEASUREMENT RULES
Generally
Q.1. Information
1 Particulars of the following shall be given :
a) Regulation, etc.
b) Kind and quality of material.
c) Gauge, thickness or substance of material.
d) Any tests, etc.
THE FIRE PROTECTION SYSTEM INSTALLED ARE IN
FULL COMPLIANCE AND REGULATIONS
GENERALLY
PIPE WORKS
Q.7 GENERALLY
1. Purpose-made pipes and purpose-made pipe
fittings shall be described.
2. Pipes and pipe fittings which are wrapped, coated
or lined by the manufacturer shall be so described
stating the type of treatment.
3. Pipework required to be temporarily fixed in
position, dismantled for chromium-plating or other
special finishing and subsequently refixed shall be
so described.
MEASUREMENT RULES
Q.8 PIPE AND FITTING
1. Pipes (measured over all pipe fittings, short
running lengths and branches) shall be given in
metres stating the type and the normal size.
Portable FE
Hose Reel
MEASUREMENT RULES
Q.8 PIPE AND FITTING
3. Flexible pipes and extensible pipes (measured as
fully extended) shall each be so described.
Conduit
Heat detector
Q.13 CONNECTIONS
Connections to public mains, making good public
highway and any other work which may only be
carried out by a Public Undertaking or Local
Authority shall be given as a provisional sum.
MEASUREMENT RULES
EQUIPMENT AND ANCILLARIES
Q.19 Generally
1. Unless otherwise stated, equipment such as boilers,
generators, heaters, water treatment plant, tanks
cylinders, calorifiers, pumps, coolers, air-handling
unit, fans, refrigerator equipment, meters, sanitary
fittings, etc. and ancillaries such as soot doors to
boilers, valves and cocks, gauges, automatic
controls etc. shall be enumerated and related to the
specification referred to in clause Q.1.1.
MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES
Q.19 Generally
Fire Hose
Reel
Pressure
Hose Guides
Reducing Valve
TYPICAL HOSE REEL
WET RISER
Is constantly filled with water and the
supply should be capable of
maintaining a running pressure of
410kPa at the highest landing valve
and give a flow rate of 23litres per
second. The maximum running
pressure permitted with one outlet
open should be 510kPa.
COMPONENTS
Pump:
•Duty pump
•Standby pump
WATER STORAGE TANK
BIB Horizontal
HOSE
inlet breechings
inlet and outlet
cabinets
outlet valves
standpipes, bars and
keys.
DRY RISER COMPONENT
DRY RISER
Type of Fire
Extinguisher
Gas
Foam
Carbon
dioxide
(CO2)
Portable Fire Extinguisher
1. Dry powder-No
2. Testing-item.
1. CO2 cylinder-No
2. Testing-item.
POWDER EXTINGUISHERS
WATER EXTINGUISHERS
Foam extinguishers
Portable Fire Extinguisher.
Alat pemadam
mudahalih (Portable Fire
Extinguisher) digunakan
melindungi bangunan
dari bahaya kebakaran
kecil.
Carbon Portable Dry
Dioxide fire Chemical Powder
extinguisher Fire Extinguisher
COMPONENTS
Fire alarm panel
Manual break glass
Alarm bell
MANUAL BREAK GLASS
SMOKE DETECTOR
SMOKE DETECTOR
SMOKE DETECTOR
Fire alarm system is
functioning as a
components which give
warning sign to occupants in
a building if it is burning.
It normally, installed with
detector.
There is 2 type of detector,
passive (Manual break
glass) and active (Smoke
detector, heat detector, light
detector).
LIGHT
LIGHT FITINGS
FITTINGS
Emergency light
‘Keluar’ Sign
Flashing lights
SPRINKLER SYSTEM
PORTABLE FIRE
EXTINGUISHER
(DRY POWDER)
MEASUREMENT RULES
SUNDRIES
Q.30 Generally
1. Draining and refilling existing system shall be given
as a provisional or prime cost sum.
1.Heat Detector
2.Smoke Detector 6. Alarm Bell
3.Extinguishing Nozzles 7. Key Switch
4.Fire Curtain (for Louver Door / 8. Double Inter-lock Control
Opening) Panel c/w Back
5. CO2 Cylinder c/w Accessories 9. Normal / Discharge Light
MEASUREMENT RULES
BUILDER’S WORK
Q.31 GENERALLY
Q.12.4 Clips, saddles, pipe- Enumerated separately stating the type and size Nos.
hooks, holderbats,
brackets, rollers,
chairs, hangers/black
plates,
Gender-laps
Q.12.5 Pipe anchor Enumerated separately stating nominal size of Nos.
pipe, type and size of components, method of
fixing of the pipe and nature of work.
Q.13 Connection Work which may only carried out by Public P.S
Undertaking or Local Authority.
SUMMARY OF MEASUREMENT RULES
Q.15.1 Special connections, Enumerated separately stating the size, kind Nos.
special joints of ducting and also method of jointing ,
classify ;
a) Connections between ducting of differing
materials.
b) Connections between ducting and
equipment stating the nature of the
equipment.
c) Isolated joints which differ from those
given in the description of the ducting.
d) Flexible connections between ducting and
plant.
Q.15.2 Ducting turn and Enumerated separately stating type and Nos.
splitters material size of ducting
Q.15.3 Nozzle outlets, test Shall described stating size, method of jointing Nos.
holes and cores and material and thickness or gauge
access doors
Q.15.4 Cowls, terminals, Stating size and type, size of ducting and Nos.
intake louvers method of jointing.
Taking off list
_______________________________________________________________________________________________________________________
6. Testing Q.30.4
Item
TAKING OFF
LIST
1. Hose reel. -No
2. Water storage tank. -No
3. Electrical duty pump. -No
4. Diesel standby pump -No
5. Incoming pipe. -M
6. Main distribution pipe .-M
7. Rising main pipe. -M
8. Distribution pipe. -M
9. Suction pipe. -M
10. Drain pipe.- M
11. Ball float valve. -No
12. Strainer valve. -No
13. Stop valve. -No
14. Flexible connection. -No
15. Check valve. -No
16. Pressure gauge. -No
17. Pressure switch. -No
18. Automatic air release valve. -No
19. Cables. -M
20. Testing -item
1. Main fire alarm console panel. -No
2. Manual break glass. -No
3. Fire Alarm Bell. -No
4. Heat detector. -No
5. Smoke detector. -No
6. Cables. -No
7. Testing -item.
TAKING-OFF LIST
1. Preambles
2. Builder’s work
i.Exc.trench to receive hydrant pipe M
ii.Exc.trench to receive incoming pipe M
3. Pipework
i.For pillar hydrant
- 150mm dia. MSCL pipe laid in trench M
ii.For incoming pipe
- 150mm dia. MSCL pipe laid in trench M
- 150mm dia. MSCL pipe laid on slab M
- 150mm dia. MSCL pipe fixed to wall M
iii.For pump house
- 200mm dia. MSCL pipe laid on slab M
- 50mm dia. MSCL pipe laid on slab M
- 200mm dia. MSCL pipe fixed to wall M
- 50mm dia. MSCL pipe fixed to wall M
- 150mm dia. MSCL pipe fixed to wall M
TAKING-OFF LIST (Cont’d)
3. Pipework (cont’d)
iv.For hosereel
- 50mm dia. G.I pipe fixed to wall M
- 25mm dia. G.I pipe fixed to wall M
v.For sprinkler
- 150mm dia. G.I pipe fixed to ceiling M
- 100mm dia. G.I pipe fixed to ceiling M
- 80mm dia. G.I pipe fixed to ceiling M
- 65mm dia. G.I pipe fixed to ceiling M
- 50mm dia. G.I pipe fixed to ceiling M
- 45mm dia. G.I pipe fixed to ceiling M
- 32mm dia. G.I pipe fixed to ceiling M
- 25mm dia. G.I pipe fixed to ceiling M
- 150mm dia. G.I pipe fixed to wall M
- 25mm dia G.I drain pipe fixed to wall M
vi.Brasswork
- Gate valve NO
- Alarm valve NO
TAKING-OFF LIST (Cont’d)
Pipework (cont’d)
vii.Breeching inlet NO
4. Pillar Hydrant NO
5. Hose Reel System
i.Swing hose reel NO
ii.Electrical duty pump NO
iii.Diesel standby pump NO
6. Sprinkler System
i.Sprinkler head NO
ii.Sprinkler tank NO
iii.Electrical duty pump NO
iv.Electrical jockey pump NO
v.Diesel standby pump NO
7. Conduits
i. 2 x 2.5mm2 PVC cable in metal conduit M
ii. 2 x 1.5mm2 PVC cable in metal conduit M
8. Cable
i. 2 x 2.5mm2 PVC cable in metal conduit M
ii. 2 x 1.5mm2 PVC cable in metal conduit M
TAKING-OFF LIST (Cont’d)
1. Builder’s Work
a) Excavation M
2. Hose Reel System
a) Swing hose- reel No
b) Water storage tank No
c) Electrical duty pump No
d) Diesel duty pump No
e) Piping: incoming pipe M
rising pipe M
distribution pipe M
3. Fire Alarm Panel
Manual Break Glass NO
Fire Alarm Bell NO
Batteries NO
Batery Charger NO
FIRE FIGHTING SYSTEM
TAKING OFF LIST UNTUK HOSE REEL SYSTEM.
4. Brasswork
Air release valve No
Gate valve No
Check valve No
Strainer valve No
Flexible joint No
5. Equipment and Ancillaries
Concrete plinth M2
6. Pipe Support
Pipe hanger NO
7. Sundries
Testing Item
Fire fighting
Installation system
Bill of Quantities
ITEM DESCRIPTION UNIT QTY RATE RM CENT
BUILDER'S WORK
Testing
HOSE-REEL SYSTEM
D Diesel standby pump with 130 IGPM at 135 feet head. (Q.19) No 1
TO COLLECTION
FF / 01
PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. (CONT'D)
Sundries
Sundries
BUILDER'S WORK
TO SUMMARY
FF / 03
Taking Off list
Builder’s Work
– Excavate trench to receive pipe - M
Hose Reel System
– Swing hose reel - NO
– Water storage tank - NO
– Electrical duty pump - NO
– Diesel standby pump - NO
– Piping
50 mm Diameter incoming pipe - M
– Brasswork
50 mm Diameter air release valve – NO
1. Pumps. - No
2. Pipeworks. -M
3. Tee - No
4. Bend. - No
5. Valves and ancillaries. - No
6. Hydrant box. - No
7. Pillar. - No
8. Fire Extinguisher. - No
9. Electrical Works. - No
10. Testing. - Item
1. Pumps - No
Equipment - Pumps
108.7 Bhp. No 1
1 (PU 202)
2. Pipeworks
Tees
5 L.Basement
Bend
1 L.Basement
4.Hydrant
Hydrant
3 L.Basement
3
3 L. Dasar
3
3 L. 1
3
3 L. 2
3
12
5. Fire Extinguisher
4 13 L.B - L.2
52
6. Testing
7. Maintenance
Builder's Work
A
Excavate trench to receive 150mm diameter
m 17
incoming pipe, maximum depth not
exceeding 1.0m including filling in,
compaction and disposal of surplus soil as
required.
B m 7
Excavate trench to receive 50mm diameter
Galvanised Iron class 'B' incoming pipe,
maximum depth not exceeding 1.0m
including filling in, compaction and disposal
of surplus soil as described.
A no 1
Swing type hose reel drum with corrugated
hose 30.5x25mm diameter complete with
valve, bracket, 12.5mm diameter nozzle and
other accessories as described.
B no 1
Hose reel cabinet type SRI model HRS 045
or equivalent for all hose reel drum
C no 1
Electrical duty pump with the capacity of 30
igm againts 170 ft static head complete with
wiring, pump plinth and other accessories
D no 1
Diesel standy pump with the capacity of 30
igm againts 170 ft static head complete with
wiring, pump plinth and other accessories.
To collection
Item Description Unit Rate Qtty Rm
To collection
Item Description Unit Rate Qtty Rm
Fire Alarm System Installation
D no 1
150mm Diameter fire alarm bell with 24v
(d.c) suplly mounted at wall as described
Testing
To collection