The Nordex Group has seen explosive growth of orders for its AW3000 platform.
AW3000
This success is due to a track record of reliability and product innovation coming
from one of the most experienced wind energy companies in the world. The latest
evolutions are the AW140 for light-wind locations in addition to uprating options
to 3300 kW for certain configurations. Partner with the Nordex Group to make your
projects rise above the competition.
• Steel and concrete tower options with hub heights • Two-person lift; hub access from inside the nacelle;
from 80 to 137.5 meters and spacious, ergonomic nacelle design allow for
operational efficiency
• Proven and bankable designs including
double-bearing support on main shaft, glass fiber
12 KV VERSUS 690 V
and epoxy blades and DFIG electrical generation
• This configuration, proven in our wind turbines, can
remove the step-up transformer from the equation
BUILT BY OPERATORS FOR OPERATORS and is ideal for projects that are in close proximity
• Based on a scaled design of our successful to the substation
AW1500, the AW3000 provides more energy
capture per wind turbine location • The result is significant savings over the life of
the project
• Our track record of fleet wind turbine performance
includes global average availability over 98% and • Up to 50% savings in collection system costs
extremely low failure rates of major components
• Average of 1% greater energy productions due to
the avoidance of transformer electrical losses
COMPATIBILITY & CONTROL
• Zero voltage ride-through beyond current • Avoidance of maintenance and potential failures
regulatory requirements, in addition to grid of transformers
integration and reactive power solutions to allow
for maximum control for stringent grid codes
OPERATING DATA
Cut-in wind speed 4 m/s 3.5 m/s 3.5 m/s 3 m/s 3 m/s
Cut-out wind speed 25 m/s 25 m/s 25 m/s 25 m/s 20 m/s
Cold Weather Operational -30ºC to +40ºC
Temperature range (Optional)
Power factor range +/- 0.93 (1,200 kVA) dynamic between +/- 5% p.u. voltage
Zero voltage ride through Meets or exceeds global requirements
ROTOR
Swept area 7,854 m² 10,568 m² 12,305 m² 13,720 m² 15,431 m²
Power regulation Independent pitch regulated with variable speed
DRIVE TRAIN
Gearbox 3 stages: 2 planetary, 1 parallel (helical)
Bearings Double spherical roller bearings
Lubrication Pressure and splash with oil cooler/oil filter
PITCH SYSTEM
Actuation Hydraulic cylinders
Failsafes Blade-independent piston accumulators on hub
YAW SYSTEM
Type Four-point ball bearing, external gear
Slewing ring External
Braking system Disk+callipers, plus electro-mechanical brake per motor drive
GENERATOR
Type 6 poles, double feeding
Frequency 50/60 Hz
Nominal voltage 12,000 V (able to eliminate step-up transformers depending on wind farm layout)
TOWER
Steel hub height - 92 87.5 84, 112.5 82
options (m) and custom
Steel tower number - 4 3, 4 4, 5 4
of sections
Concrete hub height 100 100, 120 80, 100, 120, 137.5 120, 137.5 120
options (m)
Concrete tower number 5 5, 6 4, 5, 6, 7 6, 7 6
of sections
NACELLE
Weight (tons) 108 t (without hub)
Dimensions 10.9 m (length) 4.09 m (width) 4.15 m (height)
Transportability Four options (split nacelle), and rail capable
The technical data included in this brochure may be subject to revision without prior notice. The technical data included in this brochure is not contractually binding.