Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Elcometer 130: Soluble Salt Profiler

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

NEW

Key Features
Elcometer 130
Soluble Salt Profiler

Fast & accurate measurement of


soluble salts on surfaces - over 4 times
faster than other Bresle equivalent test
methods.

Complete a Bresle equivalent test in


just over two minutes, over 4 times
faster than the Bresle method

Multi-point conductivity
sensors for accurate display
of salt concentration

Fully portable, rugged


hand-held design ideal
for use in the field

• Store 3,500 readings in 1,000 batches

• Displays average & peak salt concentration

• 2D & 3D maps display salt profile & pass/fail graphs

• 1 Elcometer 130 SSP test is equivalent to 4 Bresle tests

• Bluetooth® to PC, iOS & Android™ devices ™

available with
compatible with

wireless technology ElcoMaster ®

sales@elcometer.com elcometer.com 1
www.elcometer.com
Elcometer 130 SSP Soluble Salt Profiler

The Elcometer 130 soluble salt profiler provides fast


and accurate measurement of the level and density
of soluble salts - over 4 times faster than other Bresle
equivalent methods.

BRESLE EQUIVALENT Stores up to 3,500 sets


of readings in 1,000
ISO 8502-9 TEST METHOD
new

alpha numeric batches

Automatic temperature
compensation ensures
accurate results

Multi-point conductivity
sensor allows the trend in
conductivity to be displayed
as a density map

Large colour LCD


screen displays
readings in µg/cm²,
ppm, µS/cm, mS/cm,
% salinity or mg/m² Non-oxidising gold
plated contacts
ensure lifetime
performance

USB

PDF

Range of measurement modes:


- Cleanliness
Email
- Bresle Method Equivalency
- Elcometer 130 Equivalency
- Conductivity
Cloud

STANDARDS:
SSPC Guide 15, NSI 009-32

available with
Suitable for use in
Cloud Computing
2 YEAR*
WARRANTY

® compatible with

wireless technology ElcoMaster ®

Elcometer 130 SSP: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and
iPod touch (5th generation). “Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively,
and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note
that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.

2
Key Features
Soluble Salt Profiler Elcometer 130 SSP

“Four Bresle equivalent readings in 2½ minutes”


Each filter paper is the size of four Bresle patches - the Elcometer 130 Soluble
Salt Profiler not only displays the individual reading, but also provides four Bresle
equivalent readings in just over two minutes.

“The new Elcometer 130 SSP doesn’t just


measure the level of soluble salts”
In addition to soluble salt levels (cleanliness) or conductivity, Large Single Reading
the Elcometer 130 SSP carries out a detailed analysis of the test area - providing
an accurate salt density profile map, pinpointing areas of high contamination
outside user defined limits.

“Accurate in all environments”


This new, easy to use, Elcometer 130 SSP has automatic temperature
compensation ensuring accuracy in all climatic conditions. Impure water can be
offset for accurate and repeatable readings.

“Each gauge is designed to last” Four Bresle Patch


Robust, durable & water resistant, the new Elcometer 130 SSP is available with a Equivalent Readings
2 year manufacturer’s warranty; giving you peace of mind.

“Generate instant reports on your PC, Android™ or


iOS mobile device”
The Elcometer 130 SSP wirelessly transmits readings, statistics and batches via
Bluetooth® or via USB straight into an inspection application or into ElcoMaster ® ,
Elcometer ’s Mobile App, for instant report generation at your desk or, using your
mobile, in the field.
Pass/Fail to User Defined Limits
“Calibration verification - peace of mind”
A Calibration Verification Tile is available for verifying the accuracy of the gauge
whilst out in the field and the verification date is recorded for use in reports.

2D Salt Density Map with


High/Low Readings
Calibration Verification Tile available
for verifying the accuracy of the gauge

3D Salt Density Profile &


Peak Salt Concentration (Hi)

elcometer.com 3
Elcometer 130 SSP Soluble Salt Profiler

How to use the Elcometer 130 Soluble Salt Profiler

1. Wearing clean disposable gloves 2. Using tweezers, remove a filter 3. Disperse the water from the
(supplied), fill a syringe with precisely paper from the pack and place it on syringe, evenly across the whole
1.6ml of deionised water. the cleaned, non-labelled side of the of the filter paper and remove any
magnetic disc supplied. bubbles from under the paper.

4. Place the magnetic disc, with wetted 5. After two minutes, carefully remove 6. As each filter paper remains on the
paper face down on to the area under the filter paper and magnetic disc from surface for two minutes, multiple tests
test, pressing firmly into any contours the test surface and place on to the can be undertaken at the same time,
or irregularities and start the 2 minute measurement electrodes. reducing inspection times further.
timer on the gauge.

7. Close the lid, ensuring that the 8. The reading will be displayed on 9. Place the filter paper in a resealable
magnetic catch is fully engaged, the screen in the chosen display mode. bag (supplied), if required for further
gauge will begin measuring. analysis.

4
Key Features
Soluble Salt Profiler Elcometer 130 SSP

Bresle Patch Equivalence


Tested under laboratory conditions in accordance with ISO 8502-9,
the Elcometer 130 SSP provides equivalent measurements to the Bresle
Patch Method.

To show equivalency of measurement


between the Bresle Method and the
Elcometer 130 SSP it is essential that Comparison between Elcometer 130 SSP & Bresle Patch
200
all parameters are identical except the
gauges under test. 180

160
For equivalency to be established,
both gauges should read a similar 140

value, taking into account the


Elcometer 130 SSP

120
accuracy and resolution of each test.
100

TEST METHOD 80

Working with the School of Materials


60
at the University of Manchester (UK)
an automated, repeatable and 40

reproducible doping method was 20

developed to apply a known salt


0
concentration uniformally over a large 0 20 40 60 80 100 120 140 160 180 200

panel. Bresle Patch

Over 200 individual tests were


undertaken across a range of
concentrations and blast profiles. RESULTS Background (inherent) contamination
within the Bresle Test Patch
“The Elcometer 130 SSP has shown that the Bresle
Nominal steel grit blast profiles measurement equivalency Test Patch has a background
• Smooth <25µm (1.0mils) contamination range of 0.88µg/cm²
is less than 0.46µg/cm²
• 25 to 50µm (1.0 to 2.0mils) (8.8mg/m2).
• 50 to 75µm (2.0 to 3.0mils) across all concentrations
• 75 to 150µm (3.0 to 6.0mils) on smooth and blasted The variation in readings between
Surface salt concentration levels substrates, almost half the the Elcometer 130 SSP and the
• 15mg/m2 to 25mg/m2 Bresle Test method are significantly
background contamination
• 25mg/m2 to 35mg/m2 within the background contamination
• 35mg/m2 to 45mg/m2 of a Bresle Patch.” range of the Bresle Patches
• 45mg/m2 to 55mg/m2 (0.88μg/cm²); being less than
• >55 mg/m2 0.41μg/cm² for concentrations below
The Elcometer 130 SSP has
undergone extensive side by side 8.0μg/cm², and less than 0.46μg/cm²
Testing was undertaken under strict comparison testing against the Bresle across concentrations below
laboratory conditions, with each Test Patch Method. 16.5μg/cm².
method tested in accordance with the
manufacturer’s instructions. For a copy of the full report and
analysis visit www.elcometer.com

elcometer.com 5
Elcometer 130 SSP Soluble Salt Profiler

Create instant reports with ElcoMaster®


What you do with the collected data is
just as important as taking the readings
themselves.
Connect
Connect gauge via
Bluetooth® to see live
readings directly on the
phone and save them
into batches.

Review
Review average,
maximum and
minimum readings
instantly.

Manage & Print


Store all data; surface
cleanliness, surface
profile, climate and
manual reports in easy
to manage folders.

Photos & Notes


USB Add photos, notes and
comments.

Image Collection
PDF Use measurement
location points on
images to indicate the
position for the next
Email reading.

Cloud Combine
Combine different
inspection parameters
ElcoMaster® is a fast, easy to use Whether you are in the field or on the (such as salt
software solution for all your data factory floor, using the ElcoMaster® contamination, surface
management and quality assurance Mobile App users can; profile, climate, dry film
needs, preparing professional inspection • Store live readings directly on to a thickness) together
reports at the click of a button. mobile device and save them into with images, notes and
other project specific
batches information into reports.
Data transferred to ElcoMaster® includes: • View graphs in real-time whilst
• Date and time stamped readings carrying out the inspection Collaborate
• Statistical values • Add notes to individual batch reading Share inspection
• Limit values • Add photographs of the test surface data securely via the
• Readings above high limit Cloud and collaborate
to each individual batch reading at
• Run charts & histograms on projects using the
the click of a button instant messaging
• Salt profile maps • Plot individual readings on to a feature in ElcoMaster®.
• Batch and gauge information location map, photograph or diagram
• Calibration information via the mobile device’s internal GPS Send
Email inspection data
• Inspection data can be transferred
from a mobile device
from mobile to PC for further analysis to a PC for further
and reporting analysis and reporting
• Generate instant .pdf1 report for or transfer data via the
submission Cloud.
1
Available on iOS devices

6
Key Features
Soluble Salt Profiler Elcometer 130 SSP

Technical Specification

Model SSP
Repeatable & reproducible measurements ■
Easy to use menu structure; in 30+ languages ■
Tough, impact, waterproof & dust resistant; equivalent to IP64 ■
Bright colour screen; with permanent back light ■
Scratch & solvent resistant display; 2.4” (6cm) TFT ■
2 year gauge warranty* ■
USB power supply; via PC ■
Calibration certificate ■
Calibration verification mode (with optional certified calibration tile) ■
Ambient light sensor; with adjustable auto brightness ■
Emergency light mode ■
Magnetic & tripod mounting points ■
Data output, USB to PC & Bluetooth to PC, Android™ & iOSǂ devices ■
On screen statistics
Number of readings (n); Mean/Average, (x); - Standard deviation (σ);
Highest reading/Peak salt concentration (Hi;) Lowest reading (Lo); ■
Coefficient of variation (CV%); Number of readings above high limit ( n )
Gauge memory
Number of individual reading sets; including salt density, pass/fail map & distribution graph 3,500
Number of batches 1,000
Measurement units & range
Surface Cleanliness - Elcometer 130 Mode 0-50µg/cm² 0-500mg/m²
Surface Cleanliness - Bresle Equivalent Method Mode 0-15µg/cm² 0-150mg/m²
Conductivity 0-6000µS/cm 0-6mS/cm
0-3000ppm 0-0.3% Salinity
Resolution
Surface Cleanliness 0.1μg/cm² 1mg/m²
Conductivity 1µS/cm 0.001mS/cm
1ppm 0.0001% Salinity
Gauge Accuracy ±1% of reading
Measurement mode
Surface Cleanliness ■
Conductivity ■
Calibration offset mode ■
Automatic temperature compensation ■
ElcoMaster® software & USB cable ■
Individual reading and profile map stored with time and date ■
Plastic transit case ■
Alpha-numeric batch names; user definable on the gauge ■
Fixed batch size mode; with batch linking ■
Delete last reading ■
Limits; (gauge & batch specific) ■
Review, copy, clear & delete batches & calibration settings ■
Trend graph; last 20 readings ■
Batch review graph ■
Analogue bar graph ■
* The Elcometer 130 SSP is supplied with a one year warranty against manufacturing defects. Gauge warranty can be extended to two years via www.elcometer.com.
ǂ
Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.

elcometer.com 7
Technical Specification C ENGLAND
Elcometer Limited
Model Description Certificate Manchester M43 6BU
Tel: +44 (0)161 371 6000
E130-SP Elcometer 130 Soluble Salt Profiler Fax: +44 (0)161 371 6010
E130-SPC Elcometer 130 Certified Soluble Salt Profiler ● sales@elcometer.com
www.elcometer.com
Operating Range 5°C - 40°C (41°F - 104°F)
4 x AA batteries or via USB BELGIUM
Power Supply Elcometer SA
(rechargeable batteries can also be used)
Tel: +32 (0)4 379 96 10
Alkaline: Approximately 30 hours Fax: +32 (0)4 374 06 03
Battery Life
Lithium: Approximately 45 hours be_info@elcometer.com
Sample Time 2 minutes www.elcometer.be

Sampling Size 110mm (4.3”) circle FRANCE


Elcometer Sarl
Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9") Tel: +33 (0)2 38 86 33 44
Weight 780g (1.72lb) Fax: +33 (0)2 38 91 37 66
Standards SSPC Guide 15 (Bresle Equivalent ISO 8502-9 Test Method) fr_info@elcometer.com
www.elcometer.fr
Packing List Elcometer 130 Soluble Salt Profiler, 3 x magnetic discs,
GERMANY
100 x high purity test papers, 250ml (8.5fl oz) pure water,
Elcometer Instruments GmbH
20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3.0ml Tel: +49(0)7361 52806 0
(0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder Fax: +49(0)7361 52806 77
strap, plastic transit case, test certificate and operating instructions, de_info@elcometer.com
USB cable, ElcoMaster® software www.elcometer.de
THE NETHERLANDS
Accessories Elcometer B.V.
Tel: +31 (0)30 259 1818
Certificate Fax: +31 (0)30 210 6666
T13027115 Calibration Verification Tile ● nl_info@elcometer.com
T13025964 Magnetic Discs (x3) www.elcometer.nl
T13024091 3.0ml / 0.1fl oz Syringe (x3) JAPAN
T13024093 Self Seal Polythene Bags (x20) Elcometer KK
T99911344 Pure Distilled Water - 250ml (8.5fl oz) Bottle with 3ml syringe Tel: +81-(0)3-6869-0770
Fax: +81-(0)3-6433-1220
T13027596 Pure Distilled Water - 1000ml (33.8fl oz) Bottle with 3ml syringe jp_info@elcometer.com
T13024094 High Purity Test Papers (x100) www.elcometer.jp
T13024092 Disposable Vinyl Gloves (x20)
REPUBLIC OF SINGAPORE
T13024098 Plastic Tweezers (x2) Elcometer (Asia) Pte Ltd
T13024087 Box of 72 Sensor Wipes Tel: +65 6462 2822
T99920130 USB Bluetooth® Adaptor V2.1+ Fax: +65 6462 2860
asia@elcometer.com
● Calibration certificate supplied as standard www.elcometer.com.sg
UNITED ARAB EMIRATES
EL Inspection & Blasting
Equipment LLC
Tel: +971 4 295 0191
Fax: +971 4 295 0192
uae_sales@elcometer.com
www.elcometer.ae
USA
MICHIGAN
Elcometer Inc
Tel: +1 248 650 0500
Toll Free: 800 521 0635
Fax: +1 248 650 0501
inc@elcometer.com
www.elcometer.com
TEXAS
Elcometer of Houston
Tel: +1 713 450 0631
Toll Free: 800 521 0635
Elcometer 130 SSP: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPhone 4, iPad Air
Fax: +1 713 450 0632
2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation). inc@elcometer.com
“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has
been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.
www.elcometer.com
Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries.
Suitable for mobile devices running Android software version 2.1 and upwards. AndroidTM and Google Play are trademarks of Google Inc. Elcometer and ElcoMaster® are registered
trademark of Elcometer Limited. All other trademarks acknowledged.
Due to our policy of continuous improvement, Elcometer Limited reserves the right to change specifications without notice.

8
© Elcometer Limited, 2017. All rights reserved. No part of this document may be reproduced, transmitted, stored (in a retrieval system or otherwise), or translated into any language, in
any form, or by any means, without the prior written permission of Elcometer Limited.
V2: 30.01.2017

You might also like