Nokia RNC Parameter Configuration
Nokia RNC Parameter Configuration
Nokia RNC Parameter Configuration
Parameter Configuration:
Module Objectives
FMCS ADJD
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
RNC object structure with IUx, RNx, features objects
WSG WANE WLCSE
CMOB WSMLC
CBCI PFL
RNC
RNAC
RNPS RNFC
RNRLC RNHSPA
RNTRM RNMOBI
IUCSIP IUPSIP
New Objects / Managed Object types
• CBCI – cell broadcast center information
• PFL – preferred frequency layer for different UE capability
• WAC – UL load control AC and several state transition control parameters
• VBTS – Virtual BTS
• VCEL – Virtual cell
• COSITE/COSRNC – co-siting objects
RNx (Radio Network) objects are just created once per RNC object with no identifiers
•RNAC – for Admission Control
•RNFC – for Feature Control (Enabling parameters for all features)
•RNHSPA – for High Speed Packet Access
•RNMOBI – for Mobility
•RNPS – for Packet Scheduler (DCH Packet Scheduler)
•RNRLC – for Radio Link Control (Mainly AM RLC parameters)
•RNTRM – for Transmission (Transport Bearer Tuning and Streaming QoS for HSPA)
WSG WANE WLCSE
CMOB WSMLC
CBCI PFL
RNC
RNAC
RNPS RNFC
RNRLC RNHSPA
RNTRM RNMOBI
IUCSIP IUPSIP
RNC Object
• COSITE/COSRNC
• COSITE object contains parameters which are of common significance to all co-site pairs within the RNC.
• COSRNC object contains parameters which need to be individually configured for each RNC in co-site pair.
• Co-siting objects can be created only after RNC along with all its sub-objects are created. [cRNC]
• VCEL
• Common configuration (virtual cell) COSITE
VCEL VBTS
for all WCDMA and I-HSPA cells RNC
controlled by neighboring network Various feature objects COSRNC
elements IUx RNx
IPQM
WRAB
• VCEL object has also a relation to
IUCS, IUPS, WRAB, FMCS/I/G and
COCO HOPG
HOPS/I/G objects.
• The maximum number of VCEL IPNB WBTS HOPI
objects in the RNW database is one.
• VCEL is an optional object. TQM HOPS
• VBTS FMCS ADJD
• Common configuration (virtual base
station) for all WCDMA and I-HSPA FMCI ADJS
base stations controlled by WCEL
neighboring network elements. FMCG ADJI
• VBTS is an optional object.
ADJG/L
• The maximum number of VBTS
WAC
WBTS Object
• The logical object of the WCDMA Base Station (Node B). A WBTS can have up to 24
WCDMA cells, and either 1 COCO (ATM transport) or 1 IPNB object (IP transport).
• If Iub transport QoS is used, WBTS connects to 1 TQM object
COSITE
VCEL VBTS
RNC
Various feature objects COSRNC
IUx RNx
IPQM
WRAB
COCO HOPG
FMCS ADJD
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
WCEL object
• The logical object of the WCDMA Cell is created to define the configuration of the
WCDMA Node B site. In 1 RNC database there can be 2800 WCELs (or 4800 due to
RAN1795: RNC 2600 coverage optimization solution).
COSITE
VCEL VBTS
RNC
Various feature objects COSRNC
IUx RNx
IPQM
WRAB
COCO HOPG
FMCS ADJD
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
Handover Path
HOPx
• The Handover Path object stores mainly Cell Reselection & Intra-Frequency HHO
parameters. One HOPx can be related to several Adjacency objects.
• The maximum number of HOPx objects within 1 category is 100.
• E.g. for different type of cells (urban, rural, macro/micro/pico)
• HOP Types: VCEL VBTS
COSITE
RNC
• HOPS — object for intra-frequency Various feature objects COSRNC
IUx RN
Handover Path IPQM
x WRAB
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
HOPx Level Parameters
Intra Frequency Inter Frequency Inter System
IntraFreqNcellHCSpriority InterFreqNcellHCSpriority GSMncellHCSpriority
IntraFreqNcellHCSthreshold InterFreqNcellHCSthreshold GSMncellHCSthreshold
IntraFreqNcellQqualMin InterFreqNcellQqualMin GSMncellQrxlevMin
IntraFreqNcellQrxlevMin InterFreqNcellQrxlevMin GSMncellPenaltyTime
IntraFreqNcellPenaltyTime InterFreqNcellPenaltyTime GSMncellQoffset1
IntraFreqNcellQoffset1 InterFreqNcellQoffset1 GSMncellTempOffset1
IntraFreqNcellQoffset2 InterFreqNcellQoffset2 HOPGId
IntraFreqNcellTempOffset1 InterFreqNcellTempOffset1
IntraFreqNcellTempOffset2 InterFreqNcellTempOffset2
EcNoAveragingWindow HOPIId
EnableInterRNCsho
EnableRRCRelease
HHOMarginAverageEcNo
HHOMarginPeakEcNo
ReleaseMarginAverageEcNo
ReleaseMarginPeakEcNo
HOPSId
Idle Mode Parameters
Not a complete list
Adjacencies
ADJx
• Adjacencies for WCDMA cell refers to a Handover relationship between two cells.
They are defined for neighbouring cells.
• ADJS — object for intra-frequency Adjacency
• ADJI — object for inter-frequency Adjacency
• ADJG/L — object for inter-system Adjacency (GSM/LTE)
• ADJD — object for detected intra-frequency Adjacency
COSITE
VCEL VBTS
RNC
COSRN
Various feature objects
C
IPQM IUx RN
x WRAB
COCO HOPG
There can be:
31 intra frequency adjacencies ( ADJS), IPNB WBTS HOPI
48 inter-frequency adjacencies ( ADJI), TQM HOPS
32 inter-system adjacencies ( ADJG),
8 inter-system adjacencies ( ADJL) & FMCS ADJD
32 detected intra-frequency adjacencies ( ADJD) FMCI ADJS
WCEL
FMCG ADJI
Handover Path objects must be created before
ADJx can be used ADJG/L
WAC
Adjacencies (ADJx)
TQM
• FMCG — object for inter-system HOPS
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
FMCX Level Parameters Threshold & Trigger Handover Cause
COSITE
VCEL VBTS
RNC
Various feature objects COSRNC
• 20 WAC objects can be configured IUx RN
IPQM WRAB
which include different sets of x
FMCI ADJS
WCEL
FMCG ADJI
ADJG/L
WAC
WAC related parameters
Parameters moved from RNC (RNC, RNAC, RNPS, RNHSPA) to WAC:
• DCHUtilRelAveWin • InactNonCPCNoBatOptT
• DCHUtilRelThrDL • InactivityTimerDownlinkDCH (structure of 8 parameters)
• DCHUtilRelThrUL • InactivityTimerUplinkDCH (structure of 8 parameters)
• DCHUtilRelTimeToTrigger • MACdflowthroughputAveWin
• EDCHMACdFlowThroughputAveWin • MACdflowutilRelThr
• EDCHMACdFlowThroughputRelThr • MACdflowutilTimetoTrigger
• EDCHMACdFlowThroughputTimetoTrigger • MSActivitySupervision
• HSDPAInitialBRULStrNRT • PrxNoiseMaxTuneAbsolute
• HSDPAMinBRULStrNRT • TrafVolPendingTimeDL
• HSDPAinitialBitrateUL • TrafVolPendingTimeUL
• HSDPAminAllowedBitrateUL • TrafVolThresholdULLow
• InactCPCBatOptT • UL_DL_activation_timer
• InactCPCNoBatOptT • WaitTimeRRC (structure of 12 parameters)
• InactNonCPCBatOptT
ADJG/L
WAC
TQM / WRAB
IUx RN
• A WRAB object contains the connection- IPQM
x WRAB
based quality control parameters.
COCO HOPG
Parameters define the service bearer and
signaling bearer specific quality targets and IPNB WBTS HOPI
related power control thresholds for each TQM HOPS
transport channel configuration
FMCS ADJD
• WCEL refers to WRAB via EbNoSetIdentifier
parameter FMCI ADJS
WCEL
• there can be 5 WRAB per RNC FMCG ADJI
ADJG/L
WAC
WANE & WSG / WSMLC & WLCSE Objects
IMSI BASED HO / LOCATION BASED SERVICE
• WANE & WSG MO groups are for the IMSI Based HO, which is optional feature
• WANE set contain PLMN id where UE is allowed to make handover.
• WSG object should be created to every subscriber (PLMN id) visiting in network and it maps subscriber
(PLMN id) to certain WANE sets
AuthorisedNetworkId GSMRoaming
AuthorisedNetworkList HomePLMN WSG-
WANE- AuthorizedNetwork PLMN HomePLMNMCC WCDMA
WCDMA AuthorizedNetworkMCC HomePLMNMNC subscriber
Authorised AuthorizedNetworkMNC HomePLMNMNCLength group
Networks AuthorizedNetworkMNCLength OperatorName Parameters
Parameters Technology SubscriberGroupid
WANEChangeOriging WSGAuthorisedNetworkId
WANEName WSGChangeOriging
- WSMLC & WLCSE object groups are for Location based service. LCS is RAN04 feature
- WSMLC: WCDMA Serving Mobile Location Center, represents a logical object with RNC specific
mobile location center parameters
- WLCSE: WCDMA Location service entity, represent a logical object with WCEL specific location
parameters
ConfAreaLevel AntennaBearing; AntHPBW
WSMLC-WCDMA AntennaCoord; CovType; WLCSE-WCDMA
RNCDelayTolRespTime Location Service Entity
Serving RNCLowDelayResponseTime EnvCharact; MaxCellBackRad
Mobile Location Center WSMLCChangeOrigin MaxCellRad; RepeaterExist
WSMLCid WLCSEChangeOrigin
WLCSEUtranCellId; WLCSEid
CBCI / PREBTS/ PFL
CBCI: Cell Broadcast Centre
• CBCI object maintains the data to the cell broadcast centre used in the service area broadcast
features.
• The maximum number of CBCI objects is 4.
• CBCI parameters can be configured only if Service Area Broadcast Protocol (SABP) is in use.
HSDPAHopsIdentifier = 6
ADJS HOPS
= 2
HOPSid
(RT)
WBTS WCEL
= 1
ADJSid HOPS
= 6
HOPSid
(HSDPA)
N r t F m c s I d e n t i f i e r = 3
Each ADJS has associated 1 HOPS for NRT, 1 for RT
R t F m c s I d e n t i f i e r = 40 WCEL
& 2 for HSDPA, sets can be reused for other cells.)
H S D P A F m c s I d e n t i f i e r =
50
= 1
FMCSid FMCS HOPS = 1
HOPSid
Each WCEL has (NRT) (NRT)
associated 1 FMCS
for NRT & 1 for RT & = 1
FMCSid FMCS HOPS
ADJD = 5
HOPSid
2 for HS(D)PA, all (RT) (RT)
can be reused for
other cells. = 2
FMCSid FMCS HOPS
(HS(D)PA) = 1
ADJDid = 7
HOPSid
(HSDPA)
FMCS parameters could be
defined on a Serving cell type
= 2
FMCSid FMCS HOPS = 3
HOPSid
basis (e.g. urban, rural,
macro/micro/pico) (RT&HS(D)PA) (RTwHSDPA)
Parameter count
Group
MO Class
HC SI PS AC PC LC Ident Other Grand Total
ADJD 16 0 0 0 0 0 1 1 18 • Ref: RNC Common
ADJG 15 0 0 0 0 0 1 1 17
ADJI 21 0 0 0 0 0 1 1 23 Production 2.0
ADJL 1 2 0 0 0 0 1 1 5
ADJS
CBCI
19
0
0
0
0
0
0
0
0
0
0
0
1
1
1
6
21
7
parameter dictionary
CMOB 0 2 0 0 0 0 1 4 7
COCO 0 0 0 0 0 0 2 119 121
COSITE
COSRNC
0
0
0
0
0
0
0
0
0
0
0
0
1
3
2
7
3
10
• 2654 visible
FMCG
FMCI
30
25
0
0
0
0
0
0
0
0
0
0
1
1
1
1
32
27 parameters for cRNC
FMCS 25 0 0 0 0 0 1 1 27
HOPG 11 0 0 0 0 0 1 1 13 product (RN7.0)
HOPI 14 9 0 0 0 0 1 1 25
HOPL 4 0 0 0 0 0 1 1 6
HOPS 7 9 2 0 0 0 1 1 20
IPNB
IPQM
0
0
0
0
0
0
0
0
0
0
0
0
0
1
16
7
16
8
• 470 hidden
IUCS
IUCSIP
0
0
0
0
0
0
0
0
0
0
0
0
6
1
15
5
21
6
parameters for cRNC
IUO
IUPS
0
0
2
0
0
0
2
0
0
0
0
0
16
7
9
13
29
20 product (RN7.0)
IUPSIP 0 0 0 0 0 0 0 6 6
IUR 2 0 2 2 0 0 4 29 39
PFL 92 0 0 0 0 0 1 1 94
RNAC 0 0 0 54 26 9 1 3 93
RNC 2 24 0 5 0 0 7 51 89
RNFC 13 1 15 9 2 1 1 15 57
RNHSPA 11 0 184 27 0 0 1 8 231
RNMOBI 61 0 11 8 2 0 1 11 94
RNPS 0 0 100 0 0 0 1 1 102
RNRLC 0 0 2 196 0 0 1 1 200
RNTRM 0 0 0 0 0 0 1 103 104
TQM 0 0 0 0 0 0 0 139 139
VBTS 7 0 1 1 0 0 1 1 11
VCEL 31 0 8 8 1 0 3 2 53
WAC 0 0 38 16 0 1 1 3 59
WANE 7 0 0 0 0 0 0 1 8
WBTS 6 0 11 33 0 6 9 67 132
WCEL 97 73 97 101 28 26 14 57 493
WLCSE 0 0 0 0 0 0 5 23 28
WRAB 0 0 0 96 0 0 1 1 98
WSG 8 0 0 0 0 0 0 1 9
WSMLC 0 0 0 0 0 0 1 32 33
Grand Total 525 122 471 558 59 43 105 771 2654
Parameter Dictionary
RAS06 Example:
PtxPrimaryCPICH
-10..50; 0.1; 33 dBm
(Range; Step; Default)
Parameter management - Overview
• Radio network parameters are managed via Netact OSS or directly via Element
Manager functionality
• Usage of Netact plan Netact CM tools
edit, analysis and OMS Element Manager
new in RU30
activation tools
recommended Netact
Database
R
e
c
o
m
m
e
n
d
e
d
RNW
Database
OMS Element Manager GUI - General