As Shown: Connect To 230
As Shown: Connect To 230
As Shown: Connect To 230
3900 2100
PBE
CIRCUIT NO.OF NO.OF OVER CURRENT SIZE OF WIRE CONDUIT
DESCRIPTION V/A VOLT AMP
NO. L.O C.O PROTECTIVE DEV. THHN/THWN SIZE
3400
S1 EXISTING WINDOW
1 LIGHTING OUTLETS 8 800 230 3.47 2P, 15AT, 240V CB NO. 2.0 mm² 20 mmØ
S2
5100
2 LIGHTING OUTLETS 8 800 230 3.47 2P, 15AT, 240V CB NO. 2.0 mm² 20 mmØ
H A L L W A Y 3 CONVENIENCE OUTLET 5 900 230 3.91 2P, 20AT, 240V CB NO. 3.5 mm² 20 mmØ
S2 S1
6850
D1 4 AIR CONDITION UNIT 1500 230 6.52 2P, 20AT, 240V CB NO. 3.5 mm² 20 mmØ
1700
D2
CKT
2
CKT TOTAL 4000 17.39
1
EXISTING BALCONY
1750
T
COMPUTATIONS:
I T = 17.39AMPSX85%DF=14.78 AMPS
USED: 30 AMPS
5700 1800 1000 7000 FOR MAIN FEEDER CONDUCTOR
7500 2 - 8 mm² THHN/THWN CU.WIRE IN
25mm dia PVC/25mm dia IMC
2 - 14 mm² THHN/THWN CU.WIRE IN
FOR SUB MAIN BREAKER USE:
2P, 30AT, BOLT-ON TYPE, 10 KAIC, 240V C.B.
32mm dia PVC/32mm dia IMC CONNECT TO 230
6000
3900 2100
30AMP
CKT
4
15A 15A
3400
EXISTING WINDOW
1 2
3 20A 30A 4
5100
H A L L W A Y
6850
D1
CKT
3
1700
D2
EXISTING BALCONY
1750
PROPOSED
1 (ONE) BEDROOM EXTENSION
W/ ROOFDECK
MR. ALBERT BARIUAN