02 - O&M CCTV Manual PDF
02 - O&M CCTV Manual PDF
02 - O&M CCTV Manual PDF
Installation At:
Prepared For:
Prime Contractors
17355 Village Green Drive
Houston, Texas 77040
This Return & Warranty Policy for Dealers (“Policy”) applies to heading “Warranty repair/replacements” above.
products and services purchased directly from the following UTC For items that do not appear in Table 1, contact Customer Service or
Fire & Security Americas Corporation, Inc. business: Interlogix or your sales representative for the applicable policy.
its successors or assigns (“Interlogix”) by an independent dealer
approved by Interlogix for resale to homeowners or independent TABLE 1: Product Warranty Periods
business integrators (“Dealers,” “you,” or “your”).
Warranty
The terms and conditions of this Policy are subject to change. The Product
Period
most recent version of the Policy controls, and will generally be
Proximity readers Lifetime
available at the Interlogix website at www.interlogix.com. If you
Cards (minimum 10 cards for return) 5 years
have questions about this Policy, contact the appropriate customer
Manufactured hardware 2 years
Access
service center or your sales representative.
Magstripe cards 1 year
All periods of days set forth herein are calendar days unless
Facility Commander Wnx, Picture Perfect,
otherwise stated.
Secure Perfect, Topaz, Diamond, Sapphire, 1 year
Alliance, Director, other software products
Warranty Repair/Replacements Fire alarm control panels 3 years
Subject to the terms and conditions of the limited warranty in Air duct detectors 3 years
effect at the time of purchase, which is set forth in the UTC Fire & Heat detectors 3 years
Fire
Security Terms and Conditions of Sale for Interlogix available at Notification appliances 3 years
our website, www.interlogix.com, and the terms and conditions of Pull stations, fire stations 3 years
this Policy, Interlogix will repair or replace defective or non- Smoke detectors 3 years
working product within the product’s warranty period set forth in
Computers, computer option cards, file
this Policy. Interlogix reserves the right to replace any product 1 year
servers, monitors, touchscreens
under warranty with new, refurbished or remanufactured product or
to refund the purchase price. For product purchased by a Dealer Hardwired contacts, hardwired sensors,
5 years
from a distributor approved by Interlogix (“Distributor”), the Intrusion passive modules and components
Dealer should check with its Distributor for the terms of the return, Wireless sensors 2 years
which will be governed by the Return & Warranty Policy for Security controls, panels, powered modules
Distributors rather than this policy. and components (e.g., Simon XT,
AdvisorOne, ZeroWire, NetworX IP 2 years
Product warranty repair/replacements of Interlogix product Communications Module, touchscreens,
purchases are only permitted for defective or non-working cellular modules, etc.)
product, which may be established via product IFS fiber transmission and UTP products Lifetime
troubleshooting with the Interlogix Tech Support department. IFS network products and media converters 3 years
Video and Transmission
In cases of established product failure for products Dealer IFS power supplies for transmission products 2 years
purchased directly from Interlogix, the Interlogix Tech Fiber Options fiber optic products 5 years
Support department will provide a case number to provide TruVision and UltraView fixed cameras 3 years
Customer Service or to submit in an RMA form. If a Dealer
TruVision analog and IP PTZ cameras 3 years
returns product to Interlogix, and Interlogix determines the
product is in working condition or NTF (No Trouble Found) then UltraView analog PTZ cameras 3 years
no compensation for the cost of the unit will be provided by UltraView IP PTZ cameras 2 years
Interlogix to the Dealer under the product warranty, even if the TruVision and UltraView LCD monitors 3 years
Dealer has conducted an exchange of the product for a customer. TruVision DVRs and NVRs 3 years
TruVision encoders and decoders 3 years
If the Dealer seeks product warranty repair/replacements of
Other
Warranty & Return Policy © 2016 United Technologies Corporation. All rights reserved.
Interlogix is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 1
Interlogix Return & Warranty Policy for Dealers
April 13, 2016
Warranty & Return Policy © 2016 United Technologies Corporation. All rights reserved.
Interlogix is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 2
Interlogix Return & Warranty Policy for Dealers
April 13, 2016
Table 2: Advanced Replacement Eligibility (in addition to All electronic components must be taped and/or contained in their
Standard Warranty) original electrostatic protective packaging or an equivalent
Product Advanced Participating Remark substitute.
Category Replacement SKU’s/Product
Eligible? Family All parts must be packed securely inside the external shipping
Access YES Pls see Table 4 carton to prevent mechanical or other damage.
Control
Fire NO Not Applicable Use External packaging must be sufficient to protect the contents from
Standard the usual hazards of shipping.
Warranty
Video and YES Pls see Table 3 Returned products should be addressed to the correct legal entity
Transmission name set forth in the RMA.
Intrusion YES Pls see Table 4 If products are being returned to Interlogix from outside of the
United States, the stated value of the returned products for customs
Voice NO Not Applicable Use
should be greater than zero, and typically should be equivalent to
Standard
the purchase price of the returned products. Further, the return of
Warranty
such products to Interlogix shall comply fully with the export
Other NO Not Applicable Use administration and control laws and regulations of the United States
Standard government and other applicable jurisdictions, and any amendments
Warranty of such laws and regulations.
The list of SKU’s eligible for Advanced Replacement in the
video & transmission and intrusion profiles are listed in Tables
3 and 4, respectively, at the end of this policy.
Credit Returns
No returns for credit or refund will be accepted unless you have
obtained a return material authorization as described in the section
entitled “Returning Interlogix products”. Interlogix will refund
or credit new, standard production items that are unused and in the
original unopened shipping cartons for a period of 120 days from
the original date of shipment; however any returned product is
subject to a 25% restocking fee if your request comes more than 60
days after the original ship date. Returns for refund or credit
beyond 120 days from original shipment date will be denied.
Products purchased as part of a kit must be returned in their
entirety (i.e., the entire kit must be returned, not separate parts) to
receive refund or credit. Refund or credit is not available for
custom, special or nonstandard products.
You must use credit within one year of the date of issue. All
returns are subject to Interlogix inspection and approval.
Warranty & Return Policy © 2016 United Technologies Corporation. All rights reserved.
Interlogix is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 3
Interlogix Return & Warranty Policy for Dealers
April 13, 2016
Warranty & Return Policy © 2016 United Technologies Corporation. All rights reserved.
Interlogix is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 4
Interlogix Return & Warranty Policy for Dealers
April 13, 2016
Table 4: INTRUSION 120-3620E 430084502-CR
Products Eligible for 120-3625E 430085001
Advanced Replacement (in
120-3652F 430085501
addition to Standard
Warranty) 120-3654F 430085502
4GFXS 120-4081 430088001
4GFXSG 120-5005 430088002
4GFXSP 120-5007 430088501
4GFXU1 120-5016 430088502
4GSTS 120-5020 430177001
4GSTSG 120-5022 430210001
4GSTSP 120-6301D 430210002
4GSTU1H 120-6301E 430210003
16-3260 120-6301S 430210004
100-5420B 120-6302C 430210005
100-5420G 120-6302E 430210006
100-5420W 120-6302F 430211001
100-5421B 120-6303C 430211002
100-5421G 120-6303D 430211003
100-5423G 120-6303E 430211004
100-5424B 120-6306E 430211005
100-5424G 120-6320 430211006
100-5424W 120-6325 430212006
120-0850 120-8150 430220001
120-0851 120-8152 430221001
120-0860 120-8206 430228001
120-0861 120-8209 430228501
120-2720E 120-8216 430237001
120-2720F 120-8217 430241006
120-3400 120-8218 430242006
120-3401 120-8220B 430242501
120-3402 120-8220G 430267001
120-3403 120-8220W 520836001-CR
120-3404 120-8221G 520845001
120-3405 120-8224B 520847001
120-3406 120-8224G 520848001
120-3407 120-8224W 520849001
120-3600-CP01 120-8226 520850001
120-3601D 120-8953 520851001
120-3601 E 120-9261 520852001
120-3601F 120-9265 521209001
120-3601S 120-9410 521209002
120-3602C 120-9412 521209003
120-3602E 120-9415 521210001
120-3602S 120-9429 521210002
120-3603D 120-9882N 521210003
120-3603E 2707AD-L5 521211001
120-3603F 2757D-L 521211002
120-3603S 420613001 521211003
120-3605-CP01 420214006
120-3605E 430062001
120-3606-CP01 430084001-CR
120-3606E 430084002-CR
120-3606S 430084501-CR
Warranty & Return Policy © 2016 United Technologies Corporation. All rights reserved.
Interlogix is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Page 5
2
EQUIPMENT DATA
SHEETS
HD-TVI Analog
Dome Cameras
720p and 1080p
Resolution Cameras
IP66
IK10
Warranty
• 3-year warranty
interlogix.com/truvision
Specifications
720p HD-TVI 1080p HD-TVI
TVD-4401 TVD-4402 TVD-4403 TVD-4404 TVD-4405
TVD-2401 TVD-2402 TVD-2403 TVD-2404 TVD-2405
Minimum Illumination Color: 0.01 lux @ f1.2 (AGC On); B/W: 0.001 lux @ f1.2 (AGC On); 0 lux with IR On
Digital S/N Ratio 52 dB (AGC Off)
Lens 2.8mm @ f2.2 2.8~12mm @ f1.4 2.8mm @ f2.2 2.8~12mm @ f1.4 2.8-12mm @ f1.4 motorized
IR Range 66 ft. (20m) 132 ft. (40m) 66 ft. (20m) 132 ft. (40m)
OSD button; TruVision Coax TruVision Coax OSD control
OSD button; TruVision Coax OSD control on TVI; TruVision Coax
On Screen Display (OSD) N/A OSD control on TVI; TruVision on TVI; TruVision Coax OSD
OSD control on 960H
Coax OSD control on 960H control on 960H
English, Japanese, Chinese, Korean, German, French, Italian, Spanish, Polish, Russian,
OSD Languages N/A English and Chinese
Portuguese, Dutch, Turkish, Hebrew and Arabic
Video Output HD-TVI Dual output: TVI and 960H Composite (when WDR is enabled, 960H output will be disabled)
Video Connector 1 - 75Ω / BNC @ TVI 1 - 75Ω / BNC @ HD-TVI; 1 - 75Ω / BNC @ 960H
Voltage Input 12VDC 12VDC/24VAC 12VDC 12VDC/24VAC
12VDC: 300 mA (Max.) 12VDC: 375 mA (Max.) 12VDC: 1 A (Max.)
Current 300 mA 300 mA
24VAC: 210 mA (Max.) 24VAC: 270 mA (Max.) 24VAC: 500 mA (Max.)
Electrical/Mechanical
Ø111
Ø100.4
(82.4 mm)
3.24 in.
3.11 in.
(79.1 mm)
1.8 in.
Ø1 (46 mm)
00
.4
(124.1 mm)
4.9 in.
3.3 in.
(83.5 mm)
HD-TVI Analog Dome Cameras
720p and 1080p Resolution Cameras
interlogix.com
Specifications subject to change without notice.
© 2016 United Technologies Corporation.
All rights reserved.
All trademarks are the property of their respective owners.
Interlogix is part of UTC Climate, Controls & Security,
a unit of United Technologies Corporation.
2016/06 (LI-1673)
TruVision Dome Brackets
Installation Manual
Interlogix is part of UTC Climate Controls & Security, a unit of United Technologies Corporation. All rights
reserved.
Trademarks and patents The TruVision name and logo are trademarks of United Technologies.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or
vendors of the respective products.
Certification
N4131
2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal
waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase
of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
Introduction 2
Specifications 14
Models
For a list of the brackets and cup bases with their corresponding cameras, see “Overview: Fixed
dome cameras by bracket” on page on page 16.
Packet contents
The package contains the following items:
• Bracket or cup base
• Accessories for installation
• Screws
Unpacking
Please check the package contents to ensure that all parts are present and in good condition.
Note: For safety purposes, the mounting surface must be able to support three times the combined
weight of the bracket, cup base, and camera.
Mounting plate
Tube
Note: The rubber ring for TVD-CB5 is pre-installed in the cup base.
• TVD-CB5A:
Note: The rubber ring for TVD-CB5A is pre-installed in the cup base.
• TVD-CB2:
Converter pan
(TVD-M2 WEBM)
Accessories
Std. 2
Gang
Back Elec. Flush
Box Box Mount Wall Mount OUTDOOR INDOOR Pendant Mount
TVW- TVW- TVD- TVD- TVD- TVF- TVW- TVW- TVD- TVD- TVD- TVF-
AWB-1 DVM CB2 CB3 CB5A CBM AWB-1 DVM CB2 CB3 CB5A CBM
Threaded Pipe
Mounts
Cat. SKU
TVD-
M5225E- Incl.
3M-N
TVD-3101 2 7 7
TVD-3102 2 7 7
TVD-3103 3, 4
TVD-3104 3, 4
TVD-3105 2 7 7
TVD-3106 2 7 7
TVD-3201 3, 4
TVD-3202 3, 4
TVD-3203 Incl.
TVD-3204 Incl.
TVD-3205 Incl.
TVF-3101 5, 6
TVF-3102 5, 6
IP
TVF-3103 5, 6
TVF-3104 5, 6
TVW-3101 3+7 8 7 7
TVW-3102 3+7 8 7 7
TVW-3103 3+7 8 7 7
TVW-3104 3+7 8 7 7
TVW-3105 3+7 8 7 7
TVW-3106 3+7 8 7 7
TVW-3107 3+7 8 7 7
TVW-3108 3+7 8 7 7
TVW-3109 3+7 8 7 7
TVW-3116 3+7 8 7 7
TVW-3117 3+7 8 7 7
TVW-3118 3+7 8 7 7
TVW-3119
TVW-3130 3+7 8 7 7
TVD-4202 Incl.
TVD-4401 2 7 7
Analog
TVD-4402 Incl.
TVD-4403 2 7 7
TVD-4404 Incl.
TVW-4101 3+7 8 7 7
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
TVD-SNB-BB TVD-BB1 TVD-BB3 TVD-BB3A TVF-BBM TVF-WBM DR-RWM-AD TVW-2G-AD TVD-M-CMA TVD-M-PMA
Wall Mount Dome Back Box Dome Back Box Dome Angled 360 Back Box 360 Angled Back Dome/Wedge 2 Gang Electrical Corner Mount Pole Mount
Back Box Back Box Box Adapter Plate Box Adapter 7.63 in.
(194mm)
ALTV2416300UL, ALTV2416300ULCB
UL Listed AC CCTV Power Supply
Rev. DSALTV2416300UL - E26I
Overview
These Altronix AC Wall Mount CCTV Power Supplies provide 24VAC or 28VAC
distributed via sixteen (16) fuse or Class 2 Rated PTC protected power limited
outputs for powering CCTV Cameras, heaters and other video accessories.
Specifications
• Input 115VAC, 50/60Hz, 2.7 amp. • AC power LED.
• 24VAC @ 12.5 amp (300VA) or • Spare fuse(s) provided
28VAC @ 10 amp (280VA) supply current. (all models w/primary and/or secondary fuses).
• Main fuse rated @ 10 amp/250V. • Unit maintains camera synchronization.
• Illuminated power disconnect circuit breaker • Ease of installation saves time and
with manual reset. eliminates costly labor.
• Surge suppression.
Models
ALTV2416300UL ALTV2416300ULCB
• Sixteen (16) fuse protected outputs. • Sixteen (16) Class 2 Rated PTC protected
• Outputs are rated @ 3.5 amp. power limited outputs.
ALTV2416300UL3 • Outputs are rated @ 2.5 amp.
ALTV2416300UL w/3-wire Line Cord. ALTV2416300ULCB3
ALTV2416300ULCB w/3-wire Line Cord.
Agency Approvals
UL Listed for Commercial CCTV Equipment
European Conformity
(UL 2044).
1.20"
3.25"
Top
12.50"
1.20" 1.20"
0.75" 11.00" 0.75"
0.9375"
1.40" 1.40"
5.10" 5.10"
Left Right
5.10"
6.5625"
0.9375"
3.25" 3.25"
Bottom
3.25"
1.00" 1.00"
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
Premise Connectivity Systems
SPECIFICATIONS
Signamax BNC-style feed-thru connector patch panels may be used with a number of telecommunications applications –
networking, video and audio distribution, VHF equipment, test and measurement, etc. Based on 50- or 75-Ohm BNC
feed-thru keystone-type modules, these panels provide high-quality standard-compliant connections to active equip-
ment or cross-connections between cabling segments. Two panel density designs, “standard-density” and “high-density”
provide flexibility in managing access and cable entry space. Easy field-configuration of Signamax multimedia panels al-
lows quick replacement of individual modules during reconfigurations and upgrades. Available in 12-, 16-, 24-, 32-, and
48-port sized in standard-density design and in 24- and 48-port sizes in high-density design.
KEY FEATURES
• 50- and 75-Ohm feed-thru versions • Field configurable
• Standard-density – 12-, 16-, 24-, 32-, and 48-port sizes • Maximum strength and durability construction
• High-density – 24- and 48-port sizes • Snap-in rear cable management bar (high-density de-
sign only)
ORDERING INFORMATION
Standard-Density BNC Feed-Thru Patch Panels
www.signamax.com
16295 N.W. 13th Avenue, Suite A Miami, FL 33169 800.446.2377 305.944.7710 Fax: 305.949.4483
Copyright 2007 Signamax/AESP, Inc. All rights reserved Signamax Connectivity Systems is a trademark of AESP, Inc. Specifications subject to change PSS.BNC-FT-PP A-APR-11
Premise Connectivity Systems
SPECIFICATIONS
SPECIFICATIONS
• TRANSMISSION PERFORMANCE
Bandwidth: 50-Ohm: 0-4 GHz
75-Ohm: 0-2 GHz
• TRANSMISSION MEDIA
Coaxial cable
• ELECTRICAL
Characteristic impedance: 50 Ohm
75 Ohm
Operating voltage: < 500 V
• MECHANICAL
Diameter: 11.1 mm (0.436 in), outer, typical
• CONSTRUCTION
Panel: standard-density: body: steel
high-density: body: steel/Ni plated steel
cable management bar: steel/plastic
• DIMENSIONS
19-in rack mountable:
standard-density:
12-port: W 482.60 mm (19.000 in) H 44.45 mm (1.75 in) 1 RMS
16-port: W 482.60 mm (19.000 in) H 44.45 mm (1.75 in) 1 RMS
24-port W 482.60 mm (19.000 in) H 88.90 mm (3.50 in) 2 RMS
32-port W 482.60 mm (19.000 in) H 88.90 mm (3.50 in) 2 RMS
48-port W 482.60 mm (19.000 in) H 133.35 mm (5.25 in) 3 RMS
high-density:
24-port: W 482.60 mm (19.000 in) H 44.45 mm (1.75 in) 1 RMS
48-port: W 482.60 mm (19.000 in) H 88.90 mm (3.50 in) 2 RMS
• ENVIRONMENTAL CONDITIONS
Storage temperature: -40 °C – +68 °C (-40 °F – 154 °F)
Operating temperature: -10 °C – +60 °C (-14 °F – 140 °F)
Humidity: 10 %–90 % RH
• COMPLIANCE
UL 94V-0
• WARRANTY
5-year limited component warranty
RELATED PRODUCTS
www.signamax.com
16295 N.W. 13th Avenue, Suite A Miami, FL 33169 800.446.2377 305.944.7710 Fax: 305.949.4483
Copyright 2007 Signamax/AESP, Inc. All rights reserved Signamax Connectivity Systems is a trademark of AESP, Inc. Specifications subject to change PSS.BNC-FT-PP A-APR-11
611/2015 Hinged Wall Mount Brackets 1 Signamax Connectivity Systems
!~~~~YSTE~
Hinged Wall Mount Brackets
Overview
OVERVIEW
Hinged Wall Mount Brackets are designed for mounting one or more 19-inch panels and have a 6-inc h standoff depth. Brackets are constr ucted
from 16-gauge steel with a black polyurethane finish. Brackets have cable access holes on both the rear and sides of the brackets to allow a
variety of cable access configurations. Brackets can be mounted for either right or left hand swing.
Key Features
KEY FEATURES
• 19-inch rack mount standard
• EIA standard-spaced 10-32 holes
• 1-2-3-4-5 RMS
• 6-inch standoff depth
• Cable access holes on both the rear and sides
• Right or left hand swing
• 16-gauge steel with a black polyurethane finish
Specifications
SPECIFICATIONS
Downloads
DOWNLOADS
Ordering Information
ORDERING INFORMATION
I Where to Buy I
Part Number Description
CN-7B825**-25 25 Foot
800-245-4964 • www.westpenn-wpw.com
CN-7B25825**-25 25 Foot
Security Accessories
75 Ohm BNC Compression Style 75 Ohm BNC Compression Style
Catalog No. Description
CN-CSBNC-25 Multi-Piece Miniature 25Awg. 825
CN-CSBNC-59 1 Pc. RG59/U PVC
CN-FS59BNCPL4 1 Pc. RG59/U Plenum
CN-CSBNC-6 1 Pc. RG6/U PVC
CN-CSBNC-25 CN-CSBNC-59 CN-FS6BNCPL2 1 Pc. RG6/U Plenum
CN-CSBNC-11 RG11/U - Use TL-CSBNC-11 Tool
CN-BNCP-RGB
75 Ohm BNC Compression Style- Window
Smaller CN-BNCP-RGB 1 Pc. Miniature 25Awg. RGB- Window
Profile CN-BNCP-825 1 Pc. MiniMax 25Awg. 825 -Window
Compression CN-BNCP-59 1 Pc. RG59/U Window
Design CN-BNCP-6 1 Pc. RG6/U Window
Security Accessories
75 Ohm BNC Crimp Style Colored Rings are available- See page 110
DTK-PVP27BTPV
DTK-PVP27B
DTK-PVP27B DTK-PVP27BTPV
Product Features
One DITEK Center 1-800-753-2345 Direct: 1-727-812-5000 Document: SPS-100062-001 Rev 8 09/14
1720 Starkey Road Technical Support: 1-888-472-6100 ©2014 DITEK Corp.
Largo, FL 33771 www.ditekcorp.com Specification Subject to Change
DTK-PVP Series
Fixed Cam era Surge P rotector
General P roduct Specifications
Specifications:
DTK-PVP27B DTK-PVP27BTPV
Impedance: 75 Ω n/a
2.8VDC (C–S)
Clamping (Video): 6.8VDC
30V (C–G)
Housing: ABS
One DITEK Center 1-800-753-2345 Direct: 1-727-812-5000 Document: SPS-100062-001 Rev 8 09/14
1720 Starkey Road Technical Support: 1-888-472-6100 ©2014 DITEK Corp.
Largo, FL 33771 www.ditekcorp.com Specification Subject to Change
VIDEOBALUNS
UNLIMITED BL3265
Model BL3265
Features
• No Tools Required • Installs in Less Than 1 Minute
• Transmits Video 2000 Feet or More* • No Wire Stripping Required
• No Need to Hassle with Screw Terminals • UL Listed for the U.S. and Canada
• Cabling Cost Savings up to 50%
Press/Click down IDC connectors The EZ-VU BL3265 allows the replacement of coaxial cable with ordinary unshielded
twisted pair (UTP) cable. This allows CCTV equipment to be installed using easy to use
and less expensive UTP cable.
The EZ-VU BL3265 incorporates a unique UTP connector which allows a rapid installation
with no tools required, not even wire strippers. The latest technology has been incorporated
in order to make installations as simple as possible.
The EZ-VU BL3265 is suitable for any application in which baseband video is transmitted in NTSC,
PAL or Secam formats such as CCTV cameras, monitors, multiplexers, switchers and DVR’s.
Monitor
Video 2000ft (610m) or more
Camera
Video Video
Balun Balun
Balun Balun
Balun Balun
Balun
Balun
Balun
Balun
15.8 mm 58.0 mm
0.625" 2.282"
21.0 mm
0.8125"
Specifications
All information provided in this document is the exclusive property of Videobaluns Unlimited and
any reproduction of this document or unauthorized use is strictly prohibited without the expressed
permission of Videobaluns Unlimited, LLC.
Description:
4 pair Category 5e shielded twisted pair (F/UTP) cable, plenum communication (CMP) FT6 rated UL (or ETL)
Listed with 24 AWG solid bare copper conductors, FEP insulation, PVC jacket and a ripcord, 1000 - 0
(descending) footage marking. UL (or ETL) Verified to TIA/EIA-568 (Latest Revision) Category 5e and sweep
tested to 350 MHz
Physical Information:
UL Listing: CMP Conductor Color Code Pair
Insulation Type FEP Blue & White/Blue 1
Jacket Type PVC Orange & White/Orange 2
Jacket Diameter: 0.230” Green & White/Green 3
Voltage Rating: 300 V Brown & White/Brown 4
Temperature Rating: -20°C to 75°C
Print Legend*: HONEYWELL P/N 5388 SHIELDED 4PR24 CAT 5E EEEEEE (AAA) CL2P OR CMP
C(AAA)US FT6 75C (RoHS) BBB VERIFIED TO TIA-568-(NNN) CAT 5E XXXXXXXX
YYYY FT RM# A B C D E F 1 2 3 4 5 6 7 8 9
EEEEEE – UL or ETL listing #
AAA – UL or ETL
BBB – Verification UL or ETL
NNN – Most Recent Revision of TIA/EIA – 568 Standard (I.e. 568-C.2)
XXXXXXX – Tracking #
YYYY – Countdown Footage Marking Number
Electrical Characteristics:
5388
09/26/14 - JM Page 1 of 1
GENESIS SERIES
Coaxial Cable
Part No. 5351
Description: 20 AWG RG59/U PLENUM COAX CABLE. (ETL) CL2 OR CM
C(ETL)US FT6 listed.
Compliance: UL13 & 444, NEC 725 & 800, CSA 22.2 No. 214
Construction:
Conductor 20 AWG Solid Bare Copper (0.032" Dia.)
Insulation
Type Foam FEP
Color White
Thickness 0.052" nom.
Diameter 0.135" nom"
Braid
Strands 0.0063" nom. Bare Copper
% Coverage 95 nom.
Jacket
Type PVC Plenum
Color Natural
Thickness 0.020" nom.
Diameter 0.200" nom.
Legend (Ink Print) HONEYWELL P/N 5351 CCTV PREMIUM RG 59/U 20 AWG 3038058 (ET) CL2P OR
CMP C(ETL)US FT6 W/O# XXXXXX-XXXXXX C(ETL) CMP FT6 XXXXFT (RoHS)
CAMERA/ZONE A B C D E F 1 2 3 4 5 6 7 8 9
Properties
Temperature Rating 0 to 60 oC
Capacitance 16 pf/ft nom.
Impedance 75 Ohms nom.
Velocity of Propagation 82%
Resistance 10.1 Ohms/M' at 20oC
Resistance (Shield) 2.6 Ohms/M' at 20oC
Attenuation (db/100') 0.24 at 1 MHz, 6.2 at 400 MHz, 11.4 at 1000 MHz
Flame Rating NFPA 262, CSA FT6
REV A 09/01/10 OA
GENESIS SERIES
Coaxial Cable
Part No. 5104
Description: 20 AWG RG59/U COAX + 18 AWG 2/C FOR WET LOCATION
Construction:
Conductors 20 AWG Solid Bare Copper Center Conductor
2 - 18 AWG 16/30 Stranded Bare Copper
Braid
Strands 0.005" nom. Bare Copper
% Coverage 95 nom.
Water Blocking Water Swellable Material
Applied Under Jacket
REV A 09/01/10 OA
GENESIS SERIES
Low Voltage Cable
Part No. 3114
Construction:
Conductor 18 AWG 19/0.0092” Stranded Bare Copper
Insulation Plenum PVC
Color Blk, Red
Thickness 0.007" nom.
Diameter 0.060" nom.
Lay Length 3.25" nom.
Jacket
Type Plenum PVC
Color Natural
Thickness 0.015" nom.
Diameter 0.146" nom.
HONEYWELL P/N 3114 2C18 3038058 (ETL) CL2P OR CMP C(ETL)US FT6 (RoHS)
Legend (Ink Print) W/O# XXXXXX-XXXXXX XXXXX FT DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9
Properties
Temperature Rating -20 to 60 oC
Operating Voltage 300 Volts max.
Capacitance 28 pf/ft nom.
Impedance 72 Ohms nom.
DC Resistance 6.5 Ohms/M' at 20oC
Flame Rating NFPA 262, CSA C22.2 No. 2556 (FT6)
REV A 09/01/10 OA
3
SYSTEM OPERATION
MANUAL
TVD-2402/TVD-4402
TVD-2404/TVD-4404
2 Installation Guide
Product overview
This is the Pocket Guide for TruVision High
Definition TVI dome TVD-2402/TVD-4402 and TVD-
2404/TVD-4404. This guide describes a standard
installation.
Package contents:
Camera with power 4 screws and 4
and video output anchors for wall or
cables ceiling installation
Installation Guide 3
Hex wrench Monitor output
cable
4 Installation Guide
Camera description
3 4
5
6
9
8
Installation Guide 5
Note:
Please check the camera output settings
before setting up a system. The TVI video
output can be only connected to DVR with
TVI signal input. The CVBS output supports
the standard monitor, test monitor, encoder
and DVR.
For TVD-2402/TVD-4202, the CVBS and TVI
output can not be performed at the same time,
you can use the built-in DIP switch to select
the camera video output.
For TVD-2404/TVD-4404, the built-in DIP
switch is used to enable/disable WDR feature,
when WDR feature is enabled, the CVBS
output will be blocked out.
6 Installation Guide
DIP switch
Installation
To install the camera on a ceiling:
1. Using the template, place it level against the
mounting surface and mark the position of the
mounting holes.
Installation Guide 7
2. Following all local codes, drill and prepare the
mounting holes.
3. Remove the camera from its back box.
4. Loosen the three set of screws on the edge of
the bubble with the supplied hex wrench.
5. Remove the bubble and the dome liner.
8 Installation Guide
Note: Please remove the rubber knockout for
cable routing outside of the camera, when
required.
7. Using a 75-ohm coaxial video cable, connect
the camera TVI video output and a TVI DVR,
and connect a 12 VDC or 24 VAC power
supply to the power cable.
8. Align the camera with the back box and tighten
the set screws to secure the camera to the
back box.
Installation Guide 9
7. Adjust the surveillance angle:
1) View the camera image on a monitor.
2) Rotate the panning table to adjust the pan
direction [0 to 355°].
3) Loosen the tilting lock screw.
4) Rotate the tilting table to adjust the tilt
direction [0 to 90°].
5) Tighten the tilting lock screw.
6) Rotate the camera lens holder [0 to 355°]
to adjust the lens to the surveillance angle.
10 Installation Guide
~
~
8. Zoom and focus adjustment.
1) View the camera image using the monitor.
2) Loosen the zoom lever and move the
screw between T (Tele) and W (Wide) to
obtain the appropriate angle of view.
3) Tighten the zoom lock screw.
4) Loosen the focus lever and move the
screw between F (Far) and N (Near) to
obtain the optimum focus.
5) Tighten the focus lock screw.
Installation Guide 11
Zoom Focus
Programming
Programming on TVI output:
Once the camera hardware has been installed, you
can configure the camera settings on the TVI DVR.
TVI
12 Installation Guide
Please select PTZ protocol as TruVision Coax and
click menu button to call up the camera menu.
TVI
CVBS
TVD-2402/TVD-4402
Installation Guide 13
The camera has CVBS and TVI selectable video
output. Please set the built-in DIP switch to CVBS
for viewing the program on a standard monitor.
TVD-2404/TVD-4404
14 Installation Guide
Menu
TVD-2402/TVD-4402:
Installation Guide 15
TVD-2404/TVD-4404:
16 Installation Guide
Specifications
Power supply 24 VAC/12 VDC
Current TVD-2402/ TVD-4402:
12 VDC: Max. 300 mA
24 VAC: Max. 210 mA
TVD-2404/TVD-4404:
12 VDC: Max. 375 mA
24 VAC: Max. 270 mA
Power TVD-2402/ TVD-4402:
consumption 12 VDC: Max. 3.5W
24 VAC: Max. 5W
TVD-2404/TVD-4404:
12V DC: Max. 4.5W
24V AC: Max. 6.5W
Weight (net) 641 g / 1.41 lb. (without back box)
932 g / 205 lb. (with back box)
Dimensions Ø145.3 x 124.2 mm
(Ø 5.72 x 4.89 in. )
Installation Guide 17
Legal and Regulatory
information
Copyright:
© 2015 United Technologies Corporation,
Interlogix is part of UTC Building & Industrial Systems, a unit of
United Technologies Corporation. All rights reserved.
Manufacturer:
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification:
N4131
18 Installation Guide
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may
be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-0330 du Canada.
Contact information:
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu
Installation Guide 19
ALTV2416UL Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV2416ULX • ALTV2416ULCBX
- 24VAC @ 7 amp (170VA) - 24VAC @ 7 amp (170VA)
or 28VAC @ 6 amp (170VA). or 28VAC @ 6 amp (170VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416300UL • ALTV2416300ULCB
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416300ULM • ALTV2416300ULCBM
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416600UL • ALTV2416600ULCB
- 24VAC @ 25 amp (600VA) - 24VAC @ 25 amp (600VA)
or 28VAC @ 20 amp (560VA). or 28VAC @ 20 amp (560VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Rev. 040506
Overview:
These Altronix CCTV Power Supplies provide 24VAC/28VAC distributed via sixteen (16) fuse or PTC protected
outputs for powering CCTV Cameras, heaters and other video accessories.
Agency Listings
Current (Power)
Outputs (Class 2
Output Voltage
Primary In-line
115VAC 60Hz
PTC Protected
Main Fuse
Input Current
Fuse Ratings
Fuse Ratings
Total Output
power limited
Ratings
1 Outputs
Altronix
tions).
Model Number
ALTV2416ULX 24VAC 7 amp 16 ------ Yes 3.5 amp 3.5 5A/ 3.5A/ 1.8
28VAC 6 amp amp 250V 250V amp
ALTV2416ULCBX 24VAC 7 amp 16 Yes ------ 2.5 amp ------ 5A/ 3.5A/ 1.8
28VAC 6 amp 250V 250V amp
ALTV2416300UL 24VAC 12.5 amp 16 ------ Yes 3.5 amp 3.5 15A/ ------ 2.7
28VAC 10 amp amp 32V amp
ALTV2416300ULCB 24VAC 12.5 amp 16 Yes ------ 2.5 amp ------ 15A/ ------ 2.7
28VAC 10 amp 32V amp
ALTV2416300ULM 24VAC 12.5 amp 16 ------ Yes 3.5 amp 3.5 ------ 2.7
28VAC 10 amp amp amp
ALTV2416300ULCBM 24VAC 12.5 amp 16 Yes ------ 2.5 amp ------ ------ ------ 2.7
28VAC 10 amp amp
ALTV2416600UL 24VAC 25 amp 16 ------ Yes 3.5 amp 3.5 15A/ ------ 5.4
28VAC 20 amp amp 32V amp
ALTV2416600ULCB 24VAC 25 amp 16 Yes ------ 2.5 amp ------ 15A/ ------ 5.4
28VAC 20 amp 32V amp
Specifications:
• UL Listed for Commercial CCTV Equipment (UL 2044). • Ease of installation saves time & eliminates costly labor.
CUL Listed - CSA Standard C22.2 No.1-98, Audio, • Spare fuses included (on fuse protected models).
Video and Similar Equipment. Enclosure Dimensions:
• Surge suppression. ALTV2416300ULM and ALTV2416300ULCBM:
• AC power LED indicator. 8.5”H x 7.5”W x 3.75”D
• Power ON/OFF switch ALTV2416ULX, ALTV2416ULCBX, ALTV2416300UL,
(ALTV2416ULX, ALTV2416ULCBX). ALTV2416300ULCB, ALTV2416600UL and
• Illuminated power disconnect circuit breaker ALTV2416600ULCB:
with manual reset (all other models). 13.5”H x 13”W x 3.25”D
• Unit maintains camera synchronization.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pgs. 11-12).
Secure enclosure to earth ground.
- 2 - ALTV2416UL Series
2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV2416ULX or
ALTV2416ULCBX (Figs. 1, 2, pgs. 4, 5). Set power disconnect circuit breaker to OFF position for all
other models (Figs. 3a-8a, pgs. 6-10).
3. All units are factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and
the wire marked [24V] is connected to the terminal marked [S].
Note: ALTV2416ULCBX set for 28VAC operation is not Class 2 Rated, not power limited.
4. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 1-8, pgs. 4-10).
Use 18 AWG or larger for all power connections.
Keep power limited (PTC protected outputs only) wiring separate from non-power limited wiring.
Minimum .25” spacing must be provided. Use separate knockouts.
5. Set power switch on power distribution board marked [PD] to ON position for models ALTV2416ULX or
ALTV2416ULCBX (Figs. 1, 2, pgs. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for
all other models (Figs. 3a-8a, pgs. 6-10).
6. Measure output voltage before connecting devices. This helps avoid potential damage.
Terminals marked [1P - 16P] are of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output voltage.
7. Set power switch on power distribution board marked [PD] to OFF position for models ALTV2416ULX or
ALTV2416ULCBX (Figs. 1, 2, pgs. 4, 5). Set power disconnect circuit breaker to OFF position for all
other models (Figs. 3a-8a, pgs. 6-10).
8. Connect devices to terminals marked [1P - 1N through 8P - 8N] on PD8 board (Figs. 1-4, pgs. 4-7,
Figs. 7-8, pgs. 9-10), or terminals marked [1P - 1N through 16P - 16N] on PD16W/PD16WCB board
(Figs. 5-6, pg. 8), carefully observing polarity.
9. Set power switch on power distribution board marked [PD] to ON position for models ALTV2416ULX or
ALTV2416ULCBX (Figs. 1, 2, pgs. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for
all other models (Figs. 3a-8a, pgs. 6-10).
10. Green LED will illuminate when power is present.
11. Upon completion of wiring, secure enclosure door with screws (supplied). Installation of cam lock is optional.
Caution: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes and in
accordance with the National Electrical Code. Use 75º C or higher rated UL insulated wiring for connecting the
unit to the mains. Replace fuses only with the same type and rating (refer to Sixteen (16) Output ALTV2416UL
Reference Chart, pg. 2).
Terminal Identification:
PD8 - Power Distribution Module
Terminal Legend Function/Description
1P - 8P AC output.
1N - 8N AC output.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
Fig. 1
ALTV2416ULX
MAIN FUSE
N
INPUT
Connected
to Door
1
COMMON
LED
FUSED
ON OFF
S
2
P
3
POWER
D1
R1
POWER
N
4
Class 1 Outputs
OUTPUTS
OUTPUTS
8
6
7
7
OUTPUTS
OUTPUTS
6
8
Class 1
Outputs
POWER
POWER
4
N
R1
D1
3
P
COMMON
FUSED
2
S
LED
1
INPUT
ON OFF
MAIN FUSE
N
P
Primary
In-line
Fuse 24VAC or 28VAC output 1
(Follow same procedure using
terminals 2P & N through 8P & N
outputs 2 through 8)
non-power limited
Ground
non-power limited
Black
XFMR XFMR
Lead
Black
Lead
- 4 - ALTV2416UL Series
Fig. 2
ALTV2416ULCBX
24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
P
OFF ON
N
INPUT
MAIN FUSE
Connected
SW1
to Door
F1
COMMON
LED
S
F8
F2
P
D1
R1
POWER
F7
F3
N
24VAC configuration
Class 2 Not Wet/
Class 3 Wet
OUTPUTS
F6
F4
28VAC configuration
Class 1 F5
F5
OUTPUTS
24VAC
F4
F6
configuration
Class 2 Not Wet/
Class 3 Wet
POWER
28VAC
F3
F7
configuration
N
Class 1
R1
D1
P
F2
COMMON
F8
S
LED
F1
SW1
INPUT
MAIN FUSE
N
ON OFF
P
Primary
In-line
Fuse 24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
non-power limited
Ground
non-power limited
115VAC input, White
60 Hz. Lead
Black
XFMR XFMR
Lead
Black
Lead
P
N
MAIN FUSE
INPUT
Connected
LED
COMMON
FUSED
to Door
S
2
P
3
D1
POWER
R1
POWER
N
4
Class 1 Outputs
OUTPUTS
OUTPUTS
8
5
7
6
OUTPUTS
OUTPUTS
7
5
8
Class 1
Outputs
POWER
POWER
4
N
R1
D1
3
P
COMMON
FUSED
2
S
LED
1
INPUT
MAIN FUSE
N
P
24VAC or 28VAC output 1
(Follow same procedure using
terminals 2P & N through 8P & N
outputs 2 through 8)
Fig. 3a
Ground
non-power limited
non-power limited
Black Lead
White Lead
XFMR*
- 6 - ALTV2416UL Series
Fig. 4
ALTV2416300ULCB
24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
P
N
OFF ON
INPUT
MAIN FUSE
Connected
SW1
F1
COMMON
LED
to Door
S
F2
F8
P
D1
POWER
R1
F3
F7
N
24VAC configuration
Class 2 Not Wet/
Class 3 Wet
OUTPUTS
F4
F6
F5
F5
OUTPUTS
F6
F4
24VAC
configuration
Class 2 Not Wet/
POWER
Class 3 Wet
F7
F3
N
R1
D1
P
F8
F2
COMMON
S
LED
F1
SW1
INPUT
MAIN FUSE
ON OFF
N
P
24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
Fig. 4a
Ground
non-power limited
non-power limited
Black Lead
White Lead
XFMR*
1 2 3 4 5 6 7 8 common 9 10 11 12 13 14 15 16
outputs N
protected P
outputs
N
N
P
P
Transformer
S
underneath XFMR*
power supply
XFMR Input
board
Fig. 6
ALTV2416300ULCBM Fig. 6a
1 2 3 4 5 6 7 8 common 9 10 11 12 13 14 15 16
outputs N
protected P
outputs
N
N
P
P
Transformer
S
underneath
power supply
XFMR Input
board
- 8 - ALTV2416UL Series
Fig. 7
ALTV2416600UL
P
N MAIN FUSE
INPUT
Connected
1
COMMON
to Door
LED
FUSED
S
2
P
3
POWER
D1
R1
POWER
N
4
Class 1 Outputs
OUTPUTS
OUTPUTS
8
6
7
7
OUTPUTS
OUTPUTS
6
8
5
Class 1
Outputs
POWER
POWER
4
N
R1
D1
3
P
COMMON
FUSED
2
S
LED
1
INPUT
MAIN FUSE
N
P
24VAC or 28VAC output 1
(Follow same procedure using
terminals 2P & N through 8P & N
outputs 2 through 8)
non-power limited
Ground
Fig. 7a
non-power limited
Black
Lead
White non-power limited
Lead
24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
P
N
INPUT
MAIN FUSE
Connected
F1
COMMON
to Door
LED
S
F2
F8
P
D1
POWER
R1
F3
F7
N
24VAC configuration
Class 2 Not Wet/
OUTPUTS
Class 3 Wet
F4
F6
F5
F5
OUTPUTS
F6
24VAC
F4
configuration
Class 2 Not Wet/
Class 3 Wet
POWER
F7
F3
N
R1
D1
P
F8
F2
COMMON
S
LED
F1
INPUT
MAIN FUSE
N
P
24VAC or 28VAC
output 1 (Follow same
procedure using terminals 2P & N
through 8P & N outputs 2 through 8)
non-power limited
Ground
Fig. 8a
non-power limited
Black
Lead
White non-power limited
Lead
- 10 - ALTV2416UL Series
Enclosure Dimensions for:
• ALTV2416300ULM
• ALTV2416300ULCBM 3.63"
8.5”H x 7.5”W x 3.75”D
1.25"
3.85"
7.25"
1.75"
1.00" 1.00"
3.85" 7.25"
3.85"
1.00"
1.00" 1.00"
7.25"
ALTV2416UL Series - 11 -
Enclosure Dimensions for:
• ALTV2416ULX
• ALTV2416ULCBX
• ALTV2416300UL
• ALTV2416300ULCB
• ALTV2416600UL
• ALTV2416600ULCB
13.5”H x 13”W x 3.5”D
Altronix Corp.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. MEMBER
II1ALTV2416ULSeries G16L
- 12 - ALTV2416UL Series
RECORD DRAWINGS
4
EQUIPMENT PLUMBING
LAUNDRY
N151 S166
N151A
MS SHOWERS ELEC
CORRIDOR MS LOCKER RM N156B S170
N155 N156
STOR
S168
MS COACH STAGE STORAGE
N153 S152A
MS RR
N156C
VEST.
N164
HS RR
HS LOCKER RM STORAGE
CORRIDOR N154 S137
N152 HS SHOWERS
N154B KITCHEN MNGR
DRY STORAGE RR LCKR RM
CM
LEARNING CENTER
S132
CUSTODIAL MENS RR WOMENS RR
CONC./TICKETS
CM
U N161 N160
N162
ASSI. RR
PLANT ENG. MP STORAGE
W STORAGE CUSTODIAL SUPPLY STORAGE
S158 S154C
S150B S164 S162
CM
CM
HOME RUNS TO BCR N105
CM
CM
HOME RUNS TO BCR N105
CM
CM
N149 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
HOME RUNS TO BCR N105
HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
HOME RUNS TO BCR N105
CM
HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
MULTI-PAIR HOME RUN TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
CM
CM
HOME RUNS TO BCR N105 LEARNING CENTER
CORR
S130
N146
FCR ELEC
N148 N147 ELEVATOR SCIENCE SCIENCE
S150A S155 S151
PREP ROOM
S153
CLOSED CIRCUIT T.V. SYSTEM
SYMBOL LEGEND
CM
CORRIDOR
CM
S110
CCTV SYSTEM HEAD END EQUIPMENT RACK PROVIDED BY
CCHE OWNER, FIELD COORDINATE FINAL LOCATION WITH OWNER
CORRIDOR
PWR
CM
N140
EACH ONE REQUIRES 115 VAC BY E.C. IN ALL LOCATIONS VEST.
CM
N151I
FACULTY
CT-2M-D21 INDOOR DOME CCTV CAMERA WITH WALL MOUNT S126
CUST.
REFERENCE MOUNTING STANDARDS FOR CLARIFICATION S124
CORRIDOR
MS COMMONS
LEARNING CENTER N101
N139
N143
EXT.
STOR.
S101C
WIRE LEGEND
HOME RUNS TO BCR N105
HOME RUNS TO BCR N105
LEARNING CENTER
18 AWG, 1 PAIR CL3 NON SHIELDED, FOR CCTV CAMERA POWER
S116
SCIENCE LEARNING
CENTER
STOR.
RG-59 COAXIAL CABLE, FOR CCTV CAMERA TERMINATIONS N141
S101C
CAT-6 PLENUM RATED CABLE, PROVIDED WITH A VIOLET JACKET VISUAL ARTS
CM
S101
CM
PWR PWR
PWRPWR
LECTURE HALL
S105
CM
CM
CM
CM
CM
HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
CM
CM
STAIR C HOME RUNS TO BCR N105
HOME RUNS TO BCR N105 HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
N128 HOME RUNS TO BCR N105
HOME RUNS TO BCR N105 CORRIDOR HOME RUNS TO BCR N105 HOME RUNS TO BCR N105
CM
CM
CM
CORR
N135 CORR
N109
KITCHEN
and is provided upon the express conditions that the same
S108D COPIER ROOM be returned to CLS Technology Inc. upon request. All
S108A
PRINCIPAL OFFICE information herein contained shall be treated as secret and
N138
CONF. RM
RR
N116A OFF A OFF B OFF A OFF B (ITIN) OFF B (ITIN) OFF A OFF A SMALL CONF
confidential. No reproduction or re-transmission of this
N136 N137 N116 N115 N114 N113 N112 N111 N110 drawing or any part thereof shall be made without the
express written consent of CLS Technology Inc.
CCTV SYSTEM
FLOOR PLAN
OCCUPANCY ADDRESS:
1701 BRINGHURST STREET
HOUSTON, TEXAS 77020
DRAWN BY: DRAWING SCALE: DATE DRAWN:
MICKEY LELAND COLLEGE PREP CCTV SYSTEM LAYOUT FLOOR 1 DLP 1/16" = 1'-0" 05/09/16
PROJECT NO.:
SCALE: 1/16" = 1' - 0"
WP C1552
DRAWING NO.
CC-01
ISSUES AND REVISIONS
DATE: ISSUED FOR:
COMPUTER REPAIR
N230
INSTRUMENTAL
MUSIC
N225
VEST.
N164
UPPER
MULTI-PURPOSE
GYM S254
N150
WEIGHT
UNIFORM/MUSIC FCR
N223 S236
LIBRARY/STOR
STAIR
N228
S234
INSTRUMENT
STORAGE
PWR PBK
N225C
LOWER
KITCHEN
STORAGE
PRACTICE ROOM S237
#1
N232
COLLABORATIVE
SPACE MOTHER
N227 S238
LEARNING CENTER
S232
CM
HOME RUNS TO FCR N220 S250
CM
CM
CM
CM
CM
CM
HOME RUNS TO FCR S236
HOME RUNS TO FCR N220
CM
CM
CM
HOME RUNS TO FCR S236 HOME RUNS TO FCR S236
CM
CM
CORRIDOR LEARNING CENTER
N222 S230
CM
FCR ELEC
N220 N221 SCIENCE
S255 SCIENCE
S251
PWR PBK
PREP ROOM
CCTV SYSTEM HEAD END EQUIPMENT RACK PROVIDED BY S253
LEARNING CENTER
LEARNING CENTER
S220
ALTV2416300ULCB ALTRONIX CAMERA POWER SUPPLIES
PWR
N218
LOWER CANOPY
CORRIDOR
N205A
FACULTY
CM
CM
CM
SCIENCE
CM
CM
N217
CT-2M-OV21 VANDAL RESISTANT DOME CAMERA WALL MOUNT
REFERENCE MOUNTING STANDARDS FOR CLARIFICATION RR
S222
CORRIDOR
S200
REFERENCE MOUNTING STANDARDS FOR CLARIFICATION
LEARNING CENTER
S218
WIRE LEGEND
LAB PREP
CORRIDOR
N217A
N215
18 AWG, 1 PAIR CL3 NON SHIELDED, FOR CCTV CAMERA POWER
SCIENCE
CUST LEARNING CENTER
N216
N202 S214
CM
STAIR C
CM
N211
CM
TEACHER WORK
ROOM
CM
N201
LOWER
HOME RUNS TO FCR N220
HOME RUNS TO FCR N220
HOME RUNS TO FCR N220
HOME RUNS TO FCR N220
RR
N203 ROBOTICS AP REC AP OFFICE
S204
STOR. AP WAITING S202
N212
AP
N213
ROOF
N214
CM
FCR ELEC
COPY ROOM S200A STORAGE
S200B
CM
CM
CM
N201C
CORRIDOR S204A
N200
VEST.
N100
LIB OFFICE
S208A
MEDIA CENTER
S208
LEARNING CENTER
LEARNING CENTER
N209
LEARNING CENTER
N208
LEARNING CENTER LEARNING CENTER This drawing and the information and design Application
N210 N207 N206
SML GRP
herein contained is the property of CLS Technology Inc.
S208B and is provided upon the express conditions that the same
be returned to CLS Technology Inc. upon request. All
information herein contained shall be treated as secret and
confidential. No reproduction or re-transmission of this
drawing or any part thereof shall be made without the
express written consent of CLS Technology Inc.
CCTV SYSTEM
FLOOR PLAN
OCCUPANCY ADDRESS:
1701 BRINGHURST STREET
HOUSTON, TEXAS 77020
DRAWN BY: DRAWING SCALE: DATE DRAWN:
MICKEY LELAND COLLEGE PREP CCTV SYSTEM LAYOUT FLOOR 2 DLP 1/16" = 1'-0" 05/09/16
PROJECT NO.:
SCALE: 1/16" = 1' - 0"
WP C1552
DRAWING NO.
CC-02