Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Handbook PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 78

Smorgon ARC-Reinforcement Handbook

Your guide
to steel
reinforcement
Smorgon ARC is a Division of The Australian Steel Company (Operations) Pty
Ltd ABN 89 069 426 955
Smorgon ARC National Office
528 Ballarat Road
Sunshine 3020 Australia

Copyright© Smorgon ARC 2001

First published 1991


Second Edition 2001

All rights reserved. No part of this publication may be reproduced, stored


in a retrieval system or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise, without the
prior written permission of Smorgon ARC. Every attempt has been made
to trace and acknowledge copyright but in some cases this has not been
possible. The publishers apologise for any accidental infringements and
would welcome any information to redress the situation.

The information and illustrations in this publication are provided as a


general guide only. The publication is not intended as a substitute for
professional advice which should be sought before applying any of the
information to particular projects or circumstances. In the event of
purchase of goods to which this publication relates, the publication does
not form part of the contractual arrangements with Smorgon ARC. The
purchase of any goods is subject to the Smorgon ARC terms and
conditions of sale.

Smorgon ARC reserves the right to alter the design or discontinue any of
its goods or services without notice. Whilst every effort has been made to
ensure the accuracy of the information and illustrations in this publication,
a policy of continual research and development necessitates changes and
refinements which may not be reflected in this publication. If in doubt
please contact the nearest Smorgon ARC sales office.

The Smorgon ARC Reinforcement Handbook


Preamble
This handbook is the latest of many publications, since the 1920s, from
ARC Engineering Company Pty Ltd and its successor, Smorgon ARC, a
member of the Smorgon Steel Group.

It has the continuing objective of providing engineering details and


properties of reinforcement available throughout Australia, together with an
interpretation of the requirements of Australian Standards within the
context of practical solutions.

The information is considered to be of value to all who work in the


structural design and construction industry – in a design office, on a
construction site or a student preparing to enter the industry.

There is considerable emphasis on the requirements of many Australian


Standards. Standards are changing continuously to ensure that the latest
practices are included. It is hoped that this publication will retain its
relevance for several years, given that the major standards for reinforcing
steel and reinforced concrete design have been recently released.

James O’Grady
Chief Engineer
Smorgon ARC

November 2001

The Smorgon ARC Reinforcement Handbook


Contents

1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2.0 Australian Codes, Standards and References . . . . . . . . . . . . . . .2
3.0 Smorgon Steel Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4.0 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.1 General Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.2 Reinforcement Production Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.3 Reinforcement Material Property Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5.0 Smorgon ARC Reinforcement Product Range . . . . . . . . . . . . . . .12
6.0 Reinforcing Bar Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
6.1 Cutting Bars to Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
6.2 Bending Reinforcement to Shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
6.3 Welding Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
6.4 Mechanical Splices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
7.0 Rust and Protective Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . .22
8.0 Quality Assurance and Quality Control . . . . . . . . . . . . . . . . . . . .25
9.0 Tolerance on Bar Manufacture . . . . . . . . . . . . . . . . . . . . . . . . . .27
10.0 Information from AS3600-2001 . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.1 Clause 1.1.2 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.2 Clause 1.4 Information on Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.3 Cover to Reinforcing Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
10.4 Section 4 Cover for Durability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
10.5 Section 5 Cover for Fire Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
10.6 Clause 6.2 Properties of Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
10.7 Clause 7.6.8.3 Class L Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
10.8 Clause 19.2 Material and Construction Requirements for Reinforcing Steel . . . . .33
10.9 Clause 19.5.3 Tolerance on Position of Reinforcement . . . . . . . . . . . . . . . . . . . .35
11.0 Reinforcing Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
11.1 Bar General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
11.2 Bar Tension Lap Length and Anchorage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
11.3 Bar Compression Lap Length and Anchorage . . . . . . . . . . . . . . . . . . . . . . . . . .48
11.4 Additional Information On Lap Splices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
11.5 Bar Hooks and Cogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
12.0 Reinforcing Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
12.1 Mesh General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
12.2 Cross-Sectional Area of Smorgon ARC Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . .55
12.3 Physical Dimensions of Smorgon ARC Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . .56
12.4 Wire and Fabric Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
12.5 Mesh Detailing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
12.6 Special Fabric Design Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Appendix A Area Comparison Table Grade D500L Mesh and D500N Bar . . . . . . . . . . . . . . .60
Appendix B Smorgon ARC Bar Bending Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Appendix C Refurbishment of Buildings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Appendix D Metric and Imperial Bars and Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Appendix E Reinforcement Bar Chairs and Spacers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70

The Smorgon ARC Reinforcement Handbook


The Smorgon ARC Reinforcement Handbook
1.0 Introduction

The Reinforcement Handbook provides information about the use of steel


reinforcement when embedded in ‘plain’ concrete, in normal reinforced
concrete or in prestressed concrete.

Other information includes guidance on some applicable Australian


Standards, design and construction tolerances, fabrication of
reinforcement and tabulated data on fabric and bars.

The major source of information is AS3600-2001, the Concrete Structures


Standard.

To design and detail concrete structures correctly, the reader will need
access to several other books and reference manuals. Some suggestions
are given in the following pages.

Recycling and restoration of older buildings is becoming more and more


economical so that modern design techniques, combined with knowledge
of the condition of the building, enable the existing reinforced concrete to
be used with only minor modifications. For this reason, historical data is
given in Appendix C, Refurbishment of Buildings.

Figure 1: Reinforcement cut, bent and bundled for


delivery to site

Figure 2: Reinforcement being tied on site

The Smorgon ARC Reinforcement Handbook Page 1


2.0 Australian Codes, Standards and References

Standards Australia is responsible for preparing and publishing those


standards that relate to building materials and design. In the preparation
of this handbook, it has been assumed that the user will have access to
a copy of the relevant standards.

All building construction within each state and territory is controlled by


its relevant building regulations. Cross-references to other Australian
Standards incorporates them into the regulations.

The Building Code of Australia, first published in 1988, was originally


intended to provide uniformity of design and construction throughout
Australia. Because each state and territory can incorporate its own special
rules, designs prepared outside your state may require checking because
of differing interpretations.

Other national bodies such as the Steel Reinforcement Institute of Australia


(SRIA), the Cement and Concrete Association (C&CA) and Austroads prepare
information helpful to the design of reinforced and prestressed concrete.

Further information may be obtained from the appropriate organisation in


each state.

Table 1: Australian Standards relevant to steel reinforcement (as at November 2001)

1. “Reinforcement Detailing Handbook”, Concrete Institute of Australia, Sydney, 1988


2. “Concrete Design Handbook”, Cement and Concrete Association of Australia, Sydney, 1989
3. “Design and Analysis of Concrete Structures”, Fairhurst and Attard, McGraw-Hill, 1990
4. “Concrete Structures”, Warner, Rangan, Hall and Faulkes, Longman, 1998
5. “After-Fabrication Hot Dip Galvanizing”, Galavanizers Association of Australia, Melbourne, Australia, 1999
6. “Two Hundred Years of Concrete in Australia”, Concrete Institute of Australia, Sydney, 1988
7. “Guidelines for Economical Assembly of Reinforcement”, SRIA, Sydney, 1988 (TPN2)
8. “Effect of Rust and Scale on the Bond Characteristics of Deformed Reinforcing Bars”, Kemp, Brenzy and
Unterspan, ACI Jrnl Proc. Vol 65, No 9, Sept 1968, pp 743-756
9. “Effect of Rust on Bond of Welded Wire Fabric”, Rejab and Kesler, Technical Bulletin No 265, American
Road Builders Association, Washington DC, 1968
10. “The Effect of Initial Rusting on Bond Performance of Reinforcement”, CIRIA report No 71, 1977

Table 2: Technical references

Page 2 The Smorgon ARC Reinforcement Handbook


3.0 Smorgon Steel Group

Smorgon Steel Group is an Australian company. Smorgon Steel is made


from 100% recycled steel at our Melbourne and Newcastle mills.

Smorgon Steel Group consists of:

• Metal recycling companies for the collection, sorting and shredding of


scrap steel.

• The Smorgon Steel mills turn the scrap steel into steel product. The
scrap is melted in a furnace. The molten steel is tested to determine the
properties of the steel. Additional trace elements are added to the
molten steel if required to meet the desired properties. The steel is then
cast into billets. The billets are rolled into straight and coiled reinforcing
bar as well as rod, merchant bar and structural sections.
Figure 3: Scrap being loaded into the charge bucket • Smorgon ARC processes the reinforcement to customer requirements.
The reinforcement is scheduled from engineers’ drawings, cut and bent
to suit, then delivered to the job site.

Scrap reinforcement, from Smorgon ARC and from the job site, is
collected by metal recycling companies and the cycle continues.

Figure 4: Steel scrap

Figure 5: Ladel of molten steel

Figure 6: Stream sample to determine the chemistry of


the steel

The Smorgon ARC Reinforcement Handbook Page 3


4.0 Glossary of Terms
4.1 General Reinforcement

Reinforcement
Reinforcement is a general term used in AS3600-2001 (Concrete
Structures Standard) and by designers, reinforcement processors and
building contractors.

Reinforcement includes deformed bars, plain bars, wire, fabric and steel
products, all of which increase the tensile and compressive stress carrying
properties of concrete.

Steel reinforcement is also the essential contributor towards crack control


of concrete structures.

Reinforcement Bar
Figure 7: Coiled bar
A bar is a finished product rolled to close tolerances. Generally regarded
as being supplied in straight lengths, it is also manufactured in coiled form.

Australian Standard AS4671 is a performance standard for reinforcing


bars. There is no distinction between:

• methods of manufacture such as coiled-bar or straight-rolled bar.

• methods of production such as quench and self temper steels and


micro-alloy steels.

• hot rolled and cold worked reinforcement.

Mill-produced lengths of straight bars range from 6 to 18 metres.


Availability of lengths varies across Australia. For local availability contact
Smorgon ARC.

Reinforcing Mesh
Figure 8: Straight rolled bar
Mesh is manufactured in flat sheets with wires up to 12 mm diameter, or
rolls for fabric with wires up to 5 mm diameter. The sheets are typically 6
metres by 2.4 metres. The fabric consists of reinforcing bar welded in
either a square or rectangular grid.

Automatic welding machines ensure that the grid of wires has consistent
spacing to provide a defined cross-sectional area for designers. The wires
are welded electronically using fusion combined with pressure. This fuses
the intersecting wires into a homogeneous section without loss of strength
or cross sectional area.

Most reinforcing fabrics available in Australia are produced from deformed


cold rolled bar of grade D500L reinforcement. One of the advantages of
cold rolling is that the applied force required to drag the wire through the
Figure 9: Mesh sheets rolling cassettes provides an automatic check of the bar’s tensile strength
in addition to the quality testing required by AS4671.

Figure 10: Mesh production

Page 4 The Smorgon ARC Reinforcement Handbook


Glossary of Terms
4.2 Reinforcement Production Terms

Hot Rolled Steel


A product rolled to final shape and tolerances at a temperature of about
1150ºC. The strength properties at room temperatures are obtained by
chemistry or by rolling techniques. The finished surface may be plain or
deformed.

Micro-Alloyed Deformed Bar and Coil


This is a low carbon, micro–alloyed high strength hot rolled reinforcing bar.
Its strength comes from a small controlled addition of Vanadium, or similar
alloying element, to the steel composition during smelting. Smorgon ARC
processes N12 and N16 coils and N40 and D450N50 mill bars as micro-
alloyed bars. Micro-alloyed bars have constant metallurgical properties
across their section which gives superior welding characteristics to quench
and self tempered bars.
The N12 and N16 coils are a continuous length of finished low carbon
steel, coiled hot as the final part of the rolling process from a billet. The
current maximum size of deformed bar available in Australia in coil form is
16 mm, although 20 mm is available overseas. Coiled bar may be
Figure 11: Hot rolled bar
straightened and then cut to length, or straightened and bent to shape in
one operation.
The surface finish and physical properties allow it to be used in its
‘as rolled’ condition. The coil mass is typically two tonnes. Coils of up to
five tonnes are produced.

Quench and Self Tempered Deformed Bar (QST)


This is a low carbon, hot rolled steel which obtains its high strength from a
mill heat treatment and tempering process. After the bar is rolled to size
and shape, it passes through a water cooling line where the surface layers
are quenched to form martensite while the core remains austenitic. The
bar leaves the cooling line with a temperature gradient through its cross-
section. The natural heat within the core flows from the centre to the
surface resulting in self tempering of the martensite. The core is still
austenitic. Finally, the austenitic core transforms to ferrite and pearlite
during the slow cooling of the bar on the cooling bed. The product
therefore exhibits a variation in mircostructure in its cross-section with a
tough tempered martensite as the surface layer, and a ductile
ferrite-pearlite core.

Hard Drawn and Cold Rolled Bar


Figure 12: Hot rolled coil A continuous length of finished material produced from coiled rod having a
very low carbon content and a yield stress of approximately 300MPa.
The hot rolled rod is subjected to two or more cold rolling operations
which produces a circular or triangular cross-section. An additional pass
through a set of deforming rollers produces the required surface pattern.
Bar, whether hard drawn or cold rolled, is covered by AS4671. Previous
codes referred to hard drawn and cold rolled products as wire.
Production can be by rolling under intense pressure, or by drawing the rod
through a ‘die’ having a diameter smaller than the rod, or both. Rolling
followed by drawing provides a smooth surface.
During rolling or drawing, the diameter of the rod is reduced to
approximately 88% of its original value. This gives a reduction in area of
approximately 20-25% with a consequent increase in length. The mass of
the original rod and the final wire coil is not changed.
The cold work process raises the yield stress of the finished bar to above
500MPa. Australian metric sizes for cold rolled bars are given in Table 28
in section 12.3.

Figure 13: Cold rolled bar

The Smorgon ARC Reinforcement Handbook Page 5


Glossary of Terms
As a generalisation, cold working rod by drawing or rolling has the following
effects on steel:
• The yield stress is increased: eg, from 300 MPa to 500 MPa
• The tensile strength is increased above the original hot rolled value: eg,
from 500 MPa to 600 MPa
• The Agt is reduced: eg, from 20% to 1.5%
• The strain ageing properties become worse
• The effect of rebending may be severe
• Galvanising bent material can increase brittleness.
Figure 14: Cold rolled bar Bar produced by cold rolling has the following characteristics:
• Close control of quality since the operation is largely automatic
• Deformations can be added during the rolling process
• The cross-section is almost circular allowing good control and thus
improved bending accuracy
• The surface appearance is rougher than hard drawn material, but this is of
little consequence for reinforcement after it is encased in concrete.
Surface roughness improves anchorage in the concrete.
• Alternately rolling followed by drawing can provide a smooth
surface finish.
• Cold rolled wire does not require a lubricant during manufacture, as does
drawn wire. Although this lubricant may postpone for a few days the
advent of rusting, the fine film of rust which appears on rolled wire soon
after exposure to weather is more likely to improve the bond than to
reduce it. See technical references 8, 9 and 10 in Table 2.

Indented Wire

Here the outer shape is formed firstly by drawing hot rolled rod through a die
of circular cross-section, and then a pattern is indented into the surface. This
term is common in Europe, but not in Australia or USA.

Cold Worked Bars (1957-1983)

Cold working is a process by which the final properties of a steel are provided
by rolling, twisting, drawing or tensioning a hot rolled steel, or by a
combination of two or more of these processes.
Between 1957 and 1983, the only high strength steels in common use were
cold worked.
Before twisting, the Grade 230 bars were either of square section (1957 to
1963) or deformed (1963 to 1983). After twisting, the yield stress (at 0.2%
proof stress) was 410MPa for design calculations and they were designated
as Grade 410C bars.
Cold worked bars are no longer produced by Smorgon ARC and are not
included in AS4671-2001.

4.3 Reinforcement Material Property Terms

Deformations
Deformations appear as a raised pattern on the surface of the bar. The overall
cross-section should be as circular as possible to facilitate uniform
straightening and bending. Deforming the surface is the final rolling operation.
The surface pattern consists of transverse deformations and longitudinal ribs.
Only the deformation contributes to the anchorage of a bar. The deformation
pattern allows considerable scope for steel makers to use additional ribs for
product and mill identification.
When considering the cross-sectional area or the mass per metre of a bar or
wire, the deformation is regarded as a redistribution of the material and not
Figure 15: The Smorgon mill mark is a vertical rib as an appendage.

Page 6 The Smorgon ARC Reinforcement Handbook


Glossary of Terms
Modulus of Elasticity
This is often called ‘Young’s Modulus’ and is denoted by the notation Es.
It is a measure of the constant relationship between stress and strain up to
the elastic limit. For all reinforcement steels Es has a value of 200,000 MPa.

The Modulus of Elasticity is the slope of the stress-strain graph prior to


yielding of the steel.

Stress and Strain in reinforcing steel


Stress is a term that allows comparison between the strength of different
sizes of the same material. Stress measures the force applied to a unit of
area and is stated in megapascals (MPa).

Example 1
• If a force of 60 kilonewtons (kN) is applied to an N16 bar of
area 200 mm2, the stress in that bar is:
= 60,000/200
= 300 newtons per mm2, 300 megapascals or 300 MPa

• If the same force is applied to an N32 bar of area 800


mm2, the stress is
= 60,000/800
= 75 MPa, a lower value because of the larger area

• Conversely, for the same stress of 300 MPa, the N32 bar
would be carrying a load
= 300 x 800 newtons
= 240 kN

Figure 16: Stress-strain curve Strain is a measure of the amount by which a tensile force will stretch the
bar. Strain is expressed in the units of ‘mm/mm’, or ‘percentage strain’
based on the original gauge length.

Example 2
Using our N16 example from above, the relationship between stress and
strain is:

• Strain
= the stress divided by Young’s Modulus
= 300/200,000
= 0.0015 mm/mm
= 0.15% of the gauge length

Using the N16 example again with a gauge length of 5 bar diameters, we have:

• Extension under load


= 0.0015 x 5 x16 mm
= 0.12 mm at a stress of 300 MPa

Example 3
For the same N32 bar at a stress of 75 MPa:

• Strain
= 75/200,000
= 0.0004 mm/mm

Obviously, a lower stress in the bar means smaller strain and thus
narrower crack widths, if they occur.

The Smorgon ARC Reinforcement Handbook Page 7


Glossary of Terms
Yield Stress of Steel

This is the property which determines the maximum usable strength of a


reinforced concrete member.

The yield stress of steel is determined by stretching a sample


(approximately 600 mm long) in a tensile-testing machine.

When a steel is tensioned, the amount by which the length


increases (called ‘strain’) is directly proportional to the load (or
‘stress’) applied to the bar in the elastic range. The ‘yield point’ of
the steel is reached when strain is no longer directly proportional to
the stress applied to the bar. Beyond the yield point the bar
behaves plastically and is permanently deformed.

With hot rolled bars, the ‘yield point’ is quite visible on the
stress–strain curve. Once the yield point is reached, the strain
increases rapidly for a minor increase in the applied load. The
stress level at yield is called the yield stress and the steel is said to
have ‘yielded’. After yield, the strength of the bar increases due to
strain hardening until the tensile strength is reached. After
maximum tensile strength has been reached, the capacity of the
bar reduces and necking is visible. Eventually the bar breaks.
Figure 17: Yield stress
In fact, if the bar is unloaded part way through the test, below the yield
point, the bar will return to its original length. This is why it is called elastic
behaviour. The yield stress measured with a second test will be at least as
high as it was during the first test.

The characteristic yield stress specified in Australian Standards determines


the Grade of the steel. Grade D500N bars must have a characteristic yield
stress not less than 500 MPa; Grade D250N and R250N bars must have a
characteristic yield stress not less than 250 MPa.

To illustrate the connection between stress, strain and yield stress, there is
also a ‘yield strain’ calculated as follows:

Yield Strain of Bars


= yield stress/modulus of elasticity
= 500/200,000
= 0.0025 mm/mm
= 0.250% of the gauge length

There are three properties that relate to each other in the elastic range:

Stress = Strain x Young’s Modulus

1. Young’s Modulus
= 200,000 MPa for all steels

2. Yield stress for Grade D500N


= 500 MPa, and
the calculated yield strain is
= 0.0025 mm/mm
= 0.250% of the gauge length

3. Yield stress for Grade R250N and D250N


= 250 MPa, and
the calculated yield strain is
= 0.00125 mm/mm
= 0.125% of the gauge length

Page 8 The Smorgon ARC Reinforcement Handbook


Glossary of Terms
Yield Stress of Cold Rolled Bar
Cold rolled bar does not exhibit a true yield point; there is no point during
a stress-strain test where true yielding is visible.

AS4671-2000 allows the 0.2% proof stress to be used as the yield stress
when there is no observable yield point.

Tensile Strength of Steel


This is the maximum stress which the steel can carry. In the
past, this strength was called the ‘ultimate tensile strength’.
It is not used directly in reinforced concrete design, however
the ratio of tensile strength to yield stress is important to
ensure a ductile failure mechanism.

Stress and Strain in Reinforced Concrete


Up to the point where the concrete starts to crack, the strains
in the steel and concrete are equal but the stresses are not.
The steel carries a much higher proportion of the applied load
at a much higher stress – because it has a higher modulus of
elasticity.

AS3600 is based on steel strengths of up to 500 MPa.


This determines all the ‘deemed to comply’ rules such as cog
lengths, transverse-wire overlaps for fabric, and the requirements
Figure 18: Cold rolled bar stress-strain curve for minimum areas of reinforcement.

Plastic and drying shrinkage are two other causes of stress in concrete.

For Australian concretes, the shrinkage strain ranges from 0.0005 mm/mm
to 0.0012 mm/mm. This range is close to the yield strain of Grade 250
bars (0.00125 mm/mm). AS3600-2001 contains rules for control of cracks
caused by shrinkage and flexure for bars and fabric up to Grade 500 (yield
strain 0.0025 mm/mm).

Ductility
Ductility is the ability of a structure to undergo large deformations and
deflections when overloaded. If a structure cannot withstand large
deformations and deflections when overloaded, then it is subject to brittle
failure.

AS4671 has introduced three ductility grades for reinforcing steel and two
ductility measures. AS3600-2001 has also retained the ductility control of
a reduced strength reduction factor for bending members with a ku > 0.4,
that is for bending members with excessive tensile steel.

The three ductility grades are Low (L), Normal (N) and Earthquake/Seismic
(E). The measures for ductility are Uniform Elongation and the Tensile
Strength / Yield Stress Ratio.

The Uniform Elongation provides a measure of the ability of the


reinforcement to deform, both elastically and plastically, before reaching its
maximum strength.

The Tensile Strength / Yield Stress Ratio is a measure of the


reinforcement’s ability to work harden when undergoing plastic
deformation. This means the strength of the steel increases when it is
loaded beyond its yield strength.

The Smorgon ARC Reinforcement Handbook Page 9


Glossary of Terms
Uniform Elongation (Agt)

Uniform elongation is a strain measure. It is a measure of the


maximum amount by which a steel sample will stretch before it
reaches maximum stress. For strains up to 1% elongation, an
extensometer is used. Elongations greater than 1% are measured
from the crossheads of the tension testing machine. Uniform
elongation can be measured manually by marking a bar at 1 mm
intervals prior to tensioning. The bar is then loaded in tension until
failure. An elongation measurement (L) is obtained by measuring
the length of the bar at a distance of 50 mm from the break for a
length between 100 marks (that is, 100 mm length prior to
tensioning). The uniform elongation for manual testing is obtained
from the formula:

L-100
Agt = ( + Tensile Strength ) x 100%
L 200,000
Figure 19: Uniform elongation

The first part of the equation measures the plastic deformation of


the bar away from the zone affected by necking. The second term
measures the elastic deformation. At failure the bar shortens as
elastic strain is relaxed, hence the elastic deformation must be
added back onto the permanent plastic deformation to obtain the
total elongation at maximum stress.

Uniform elongation is a measure of the ductility of the steel.

A steel with high uniform elongation (greater than 5%) is considered


ductile; low ductility (under 5%) is considered to be a sign of
brittleness.

Uniform elongation is not required directly for design purposes,


however, its value is important when specifying and checking the
Figure 20: Reserve strength of steel
properties of a steel. Design methods requiring high rotation, such
as moment redistribution and plastic hinge design, should not use low
ductility steels.

AS4671-2001 gives minimum values for the Uniform Elongation (Agt) for
the different reinforcing steels.

250N 500L 500N


Agt ≥5% ≥1.5% ≥5%

Page 10 The Smorgon ARC Reinforcement Handbook


Glossary of Terms
Strain Ageing

When normal mill steels such as plate, wire, and plain or deformed bars
are bent or otherwise reshaped, the steel becomes less ductile with time.
There are many reasons, but the main cause seems to be change in
crystal structure and the effects of the chemical composition.

Strain ageing causes problems when:

• the steel is bent around a small pin


• bent material is galvanised
• a weld is located close to (within 3 db) or at the bend.

Chemical Composition
The selection of the correct chemistry for any steel product is extremely
important because it can have a marked effect on the use of the final
product.

The most important elements in the composition of reinforcing steel are


Iron (Fe) Carbon (C) and Manganese (Mn). AS4671 allows both a cast
analysis and a product analysis.

Carbon
Carbon turns iron into steel. The Carbon content of steel is limited
because as the carbon content increases, the ductility of the steel
decreases.

Other Elements
• Manganese increases the strength of steel up to a certain point
• Nitrogen, Phosphorous, Silicon and Sulphur can be deleterious
• Micro-alloying and grain-refining elements, such as
Aluminium, Niobium, Titanium and Vanadium, can be used
to increase the strength but they can affect other
properties, sometimes not to the best advantage of the
steel.
• Residual elements such as Copper, Nickel, Chromium and
Molybdenum can occur in steel if they are present in any
scrap used in steel making. Up to a certain limit they may
be considered as incidental and not detrimental to the
product.

Figure 21: Carbon equivalence versus yield strength

Carbon Equivalence (CE)


This term is regarded as a measure of the weldability of a steel. It is
derived from a formula that allows for the influence of Carbon, Manganese,
Chromium, Molybdenum, Vanadium, Nickel and Copper. The Australian
formula for CE is:

C+Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu) / 15

When the CE exceeds 0.45, the steel cannot be welded (see Figure 21).

The Smorgon ARC Reinforcement Handbook Page 11


5.0 Smorgon ARC Reinforcement Product Range

Material Grade Size Range Yield stress Usage Rolling Mill Type
Plain rod R250N 6.5, 10, 12.5 mm coil 250 MPa Fitments As- rolled, rod mill
Plain rod R250N 5.5 to 14 mm coil 250 MPa Feed for wire As- rolled, rod mill
Deformed bar D500L 4 to 11.9 mm coil 500 MPa Fabric, fitments Drawn or rolled from rod
Deformed mesh D500L RF43 to RF1218 fabric 500 MPa General use Drawn or rolled from rod
Round mesh R500N 6 to 12 mm fabric 500 MPa Suspended slabs Produced under patent

Plain bar R250N R10 to R36 straight 250 MPa Dowel bars Merchant mill
Deformed bar D250N S12 straight 250 MPa Swimming pools Merchant mill
Deformed bar D500N N12 & N16 coil 500 MPa General use Rod mill
Deformed bar D500N N12 to N36 straight 500 MPa General use Merchant mill
Deformed bar D500N N40 straight 500 MPa Special order Merchant mill
Deformed bar D450N D450N50 straight 450 MPa Special order Merchant mill
Table 3: Reinforcing steel product range
The Concrete Structures Standard, AS3600, and the Reinforcing Steel
Standard, AS4671, must be regarded as interrelated performance
standards. However, although a particular reinforcing steel may comply
with, or even exceed, some of the minimum requirements of its Standard,
that steel must not be used above the maximum stress limits set down in

AS3600.

Figure 22: D500N straight stress-strain curve Figure 23: D500N coil stress-strain curve

Figure 24: D500L stress-strain curve Figure 25: D250N stress-strain curve

Page 12 The Smorgon ARC Reinforcement Handbook


Smorgon ARC Reinforcement Product Range

Grade R250N Plain Rod in Coils

This is a continuous length of semi-finished, low carbon steel, coiled hot


as the final part of the rolling process. Rod provides feed for material with
finer tolerances (eg, mesh bars), or is manufactured directly into fitments.

Rod diameters are not the same as bar sizes: rod is available in 0.5 mm
increments in the range 4 mm to 14 mm. Only selected sizes are used for
reinforcement as fitments.

Grade D500L Deformed Bar and Coil

Figure 26: D500L deformations This is a low carbon, deformed 500 MPa steel. The steel is produced in
coils by cold rolling, which is straightened to produce bars. D500L bar
and coil are available in sizes from 4 mm to 11.9 mm.

Grade D500L Mesh


Most automatically welded reinforcing fabrics in Australia are made of
deformed grade D500L bars. The bar diameters for the fabrics typically
range from 4 mm to 11.9 mm. D500L fabric is produced in standard 2.4
by 6.0 metre sheets, however purpose built sheets are available.

Grade R500N Mesh


Figure 27: D250N deformations This is a low carbon, round 500 MPa steel of Ductility Class N. The bar
diameters for the fabrics typically range from 6 mm to 12 mm. R500N
mesh is produced as purpose built sheets to suit project requirements.

Grade R250N Plain and D250N Deformed Bars


Plain round bars and deformed bars, both of Grade 250, are also
manufactured as low carbon, hot rolled steels in straight lengths.
D250N bar is available ex-stock in 12 mm only, being primarily supplied for
construction of swimming pools. The D250N12 bar is designated as
S12 reinforcement.

Figure 28: D500N coil bar deformations Grade D500N Deformed Bar
Grade D500N bar is produced as low carbon, hot rolled deformed bar in
straight lengths and in coils. Straight lengths are available from 12 mm to
40 mm diameter. 12 mm and 16 mm diameter D500N bar typically are
supplied from coils.

Grade D450N Deformed Bar


50 mm straight bar is manufactured as low carbon, hot rolled micro-
alloyed steel with a 450 MPa characteristic yield stress.

OBVERSE

REVERSE
Figure 29: D500N straight bar deformations

The Smorgon ARC Reinforcement Handbook Page 13


6.0 Reinforcing Bar Processing

Introduction
The Australian reinforcement industry involves a very short supply chain
from steel maker to consumer.

There are two steel producers, Smorgon Steel, based in Victoria and
Onesteel, based in New South Wales. Both companies roll bar and rod.

Next in the chain are the reinforcement processors/suppliers, the largest of


which is Smorgon ARC, part of Smorgon Reinforcing.

There are 47 Smorgon ARC branches in all states and territories ranging
from large plants, which manufacture mesh and process steel bar for
major projects, down to small centres situated in metropolitan and country
areas to service local needs quickly. These Smorgon ARC outlets sell to
the public as well as to building contractors. There is also a well
established reseller network which maintain stocks of fabric and other
materials.

Reinforcement Processing
The term “processing”, as used in the reinforcement industry, includes the
complete range of operations that translate information on an engineering
drawing into usable pieces of steel delivered to the building site. The
summary that follows applies to the processing of reinforcing bar:

• The bar and mesh schedule


A document giving details for manufacture, delivery and fixing prepared by
a “Scheduler”. The Scheduler reads the engineering and architectural
drawings to determine the number, size, length and shape of
reinforcement required. The schedule contains most of the instructions
that enable the following processes to be carried out.

Figure 30: Reinforcement cut, bent, bundled and


• Cutting to length
tagged
Bar reinforcement is manufactured in stock lengths as straight bars, or in
coils for sizes 16 mm and below. One or two stock lengths are held for
each bar size. As the dimensions of concrete members rarely match these
lengths, the bars must be cut to the required length.

• Bending to shape
After cutting, reinforcement may need to be bent to shape. The required
shape is determined by the shape of the concrete outline. The shape is
defined by a dimensioned sketch on the schedule and tag.

• Bundling and tagging


Following bending and/or cutting, bars of similar size and
shape are grouped and tied together. A tag identifying the
location of the steel in the structure is tied to each bundle.
This location, or label, corresponds with the member-
numbering system shown on the structural drawings. If the
structural drawings show insufficient detail to identify the
reinforcement location, a marking drawing may be required.

Figure 31: Trailer loaded with reinforcement ready to be • Delivery instructions


delivered to site
Transport from the Smorgon ARC factory to the job may be by truck or
rail, and in each case requires an identifying tag and associated delivery
instructions such as address and customer.

Page 14 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar Processing

• Invoicing

After delivery, the normal commercial procedures of invoicing for each


delivery take place. Depending on the contractual arrangements before the
commencement of the job, supply may be on the basis of a schedule of
rates per tonne, or as a lump sum cost for the total project. It is normal
practice for an agreed rise-and-fall clause to be included.

6.1 Cutting Bars to Length


For bars, the following cutting methods are available:

• Guillotine shear
This is a large machine suitable only for factory cutting. Up to 20 smaller
diameter bars can be cut at once. Although rough, the ends are suitable
for welding, where specified, but not for end-bearing splices.

• Diamond-tipped or similar saw


Factory mounted, this can produce an accurate neat end for an end-
bearing splice.

• Friction saw
A portable saw of this type can be used on site.

• Oxy-acetylene torch
For trimming or removing steel. The heat generated during cutting extends
only a short way along the bar and, as such, does not affect either the
strength or anchorage of a bar end. Take care to avoid spatter on to
adjacent steel during cutting. Bars cut using heat are not suitable for end-
butt welding.

Manufacturing Tolerances
To enable building materials to fit together, an allowance is required to
permit minor variations from the exact value specified. This allowance is
called a tolerance. Tolerances on reinforcement are given in AS4671,
Section 7, and AS3600, Section 19.

Figure 32: Guillotine shear cutting reinforcement

The Smorgon ARC Reinforcement Handbook Page 15


Reinforcing Bar Processing

Economics of Cutting Steel to Length


The need to cut scheduled lengths of steel from stock lengths has already
been mentioned in this handbook. Where possible, an order for one
scheduled length will be cut from one particular stock length. However,
the economics of steel cutting require that minimum scrap is generated.
For maximum steel utilisation then, different scheduled lengths are
grouped together to be cut from the most economic stock length.

Example A
Required Cut from stock Scrap
i. 20 x 6000 20 x 6000 0m
ii. 20 x 6000 10 x 12000 0m
iii. 20 x 6100 20 x 7000 20 x 900 mm
iv. 20 x 6100 +
20 x 3800 20 x 10000 20 x 100 mm
• In cases (i) and (ii), different stock lengths allow alternative solutions.

• In case (iii), a slight change in length causes an unacceptable scrap


length.

• Intercutting between two orders, in case (iv), reduces scrap and utilises
one stock length for two scheduled lengths.

Example B
Required Cut from stock Job

i. 20 x 6100 20 x 7000 Slab S1

ii. 20 x 6100 + Slab S1


20 x 3800 20 x 10 000 Wall W3
iii. 20 x 6100 + to job #23
20 x 3800 20 x 10 000 to job #41
• In case (i), all bars from one bundle go to the same site for one particular
slab marked S1.

• In case (ii), the two bundles go to the same site, but one bundle is used
for slab and the remainder for wall which may not be poured for another
week.

• In case (iii), because of the advantages of inter-cutting between different


orders, totally different sites would be using steel from the one heat.

These examples illustrate how widely the material from one heat can be
spread and why traceability after processing has been replaced by a
quality assurance programme, with better results at a realistic cost.

Page 16 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar Processing

6.2 Bending Reinforcement to Shape

Bar Shapes
There are several reasons for bending bars:

• Where anchorage cannot be provided to a straight length within the


available concrete shape or size, it may be necessary to bend a 180O
hook or 90O cog on the end. Hooks and cogs are never scheduled
unless they are shown on the engineer’s drawings.

• Where continuity of strength is required between two intersecting


concrete members, the bar will be bent to allow this stress transfer.
Such bends are never scheduled unless they are shown on the
engineer’s drawings.

• Where ties, stirrups, ligatures or spirals (called ‘fitments’ by the industry)


enclose longitudinal bars in a beam or a column, the fitment will be
scheduled to match the shape of the surrounding concrete. Mostly the
shape is defined by the concrete surface and the specified cover. The
actual shape is defined by the scheduler provided the designer’s
intentions are given in the drawings. The designer must indicate if
cogged or hooked ends are required.

• Where intersecting reinforcement is likely to clash, or where parallel


bars require lapping, the scheduler will decide whether or not to
provide small offsets.

Standardised Bar-Bending Shapes


The standard shapes used by Smorgon ARC are based on a combination
of Australian and American standards to utilise the best features of each
system. Smorgon ARC’s shapes are not subject to copyright. Appendix B
contains Smorgon ARC’s standard shape library.

AS3600-2001 Addresses Bending of Reinforcement


The pin diameters given in Clause 19.2.3 of AS3600-2001 have been
selected for very good reasons.

Steel is an elastic material, which means that when it is stretched it will


return to its original length after the load is released. This is true up to the
‘yield point’. When stretched in tension beyond the yield point, the
increase in length of the bar becomes permanent. The bar’s tensile
strength has not been reduced however. If this ‘stretched’ bar is stretched
again it may, under some circumstances, recover its elastic properties and
possibly also have a new yield point.

When straight steel is bent a very limited amount, it will spring back to
straight. This is because it is still in the elastic range.

When a bar is bent to shape during processing, the steel again has been
strained beyond its yield point; if it had not, it would have straightened out!
Thus all steel bending changes the material from its original state and any
investigation of its properties must allow for this.

The Smorgon ARC Reinforcement Handbook Page 17


Reinforcing Bar Processing
A similar situation exists with bars straightened from a coil. In this case the
final properties may differ from those it would have had if it had been
supplied straight, but they are the properties of the steel when used in
concrete and they must comply with the relevant standards.

Excessive bending can be classified as having a pin diameter at or below


the bend-test diameter. This can change the metallurgical structure of the
steel and can also crush the deformations thus initiating a zone of
weakness.

The diameter of a bend should not be so large that the hook cannot fit
inside the concrete or that it will pull out rather than act as a hook. Nor
should it be so small that the pressure between the bend and the concrete
will crush the concrete. A compromise value of 5db for general bending
has worldwide acceptance. One of the quality control requirements for a
Figure 33: Automatic bending machine for coil reinforcing steel is that it will pass a bend test. For bars, this test is
reinforcement described in AS4671. Despite claims made about the degree of bending
which can be sustained by some steels in a laboratory, treatment on a
building site can be much more severe. For this reason AS3600 prohibits
the use of small diameter pins at or below the bend test sizes. Cold
weather bending and the occasional on-site ‘adjustment’ also require
larger pin sizes.

Coated bars are bent about larger pins than uncoated bars. The minimum
pin diameters specified for galvanised or epoxy-coated bars are based on
three requirements:

(i) Firstly, particularly with epoxy-coated bars, damage to the coating is


more likely with small pins because of the greater pressure between
bar and pin.

(ii) Secondly, with galvanised bars, a small bending diameter is more likely
Figure 34: Manual bending machine for straight
reinforcement to break the zinc surface coating.

(iii) Thirdly, the pickling process during hot dip galvanising can lead to
hydrogen embrittlement of the reinforcement. The greater the cold
working of the steel, the more susceptible it is to hydrogen
embrittlement. The larger pin diameter for galvanised bars and for bars
to be galvanised reduces the cold working of the reinforcement.

Where there is a problem of fitting a hooked bar into a thin concrete


section, it must not be solved by using a smaller pin diameter. Instead, the
bar must be rotated, possibly up to 90º, to ensure adequate cover.

Cutting and Bending Bars from a Coil


Bar 16 mm and smaller is available in coil form, each coil being about 2
tonnes (approximately 2200 metres of N12 bar). Bars are cut from a coil,
either singly or in pairs, after passing through a straightener. Handling is
the main limit on available length.

The straightener often leaves a series of marks on the bar surface, but this
does not affect the anchorage properties.

An alternative machine permits a coiled steel to be straightened and then


bent in a continuous operation, after which the bent piece is cut from the
coil. The shape and dimensions can be programmed.

Bending Bars Cut from Stock Lengths


After cutting, a separate operation is used to produce the required shape.
Again, depending on bar diameter, one to six bars can be bent at once.

Page 18 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar Processing

Cutting and Bending Mesh


Reinforcement mesh can be cut to size in the factory using a guillotine or
cut on-site using bolt cutters. Site cutting is slow and very labour intensive.

The reinforcing fabric can be bent to suit


the concrete profile. The mesh is bent to
the required shape using equipment
specifically designed to ensure that the
bends on each wire are accurate and
within construction tolerances.

Heating and Bending


Hot bending is not a normal factory
operation. It is more likely to be done
on-site, generally with poor supervision
and inadequate quality control. Since
the strength of the steel will be reduced,
uncontrolled hot bending is a dangerous
practice.

As a general rule, heating Grade D500N


bars of any type must be avoided at all
times. AS3600-2001 Clause 19.2.3.1 (b)
gives a maximum temperature for
Figure 35: Reinforcing bar being bent about a reinforcement as 600O C. At 600O C the bar is only just starting to change
forming pin colour. If any colour change is observed whilst heating, the reinforcement
should be discarded. If the bar is heated over 450º C, the steel is softened
due to changes in the crystalline structure of the metal. Once heated over
450º C the yield strength of the bar is reduced to 250 MPa. The only
practical method of monitoring heat in the bar is the use of heat crayons.

Galvanised bars should not be hot bent.

Using Bars after Heating


Overheating beyond 600OC will alter the structure of the steel. 450OC has
been found to be a realistic limit because above this temperature the yield
stress, while under load, reduces to 250 MPa. See Clause 5.9 of AS3600
for material strengths during a fire.

On-Site Rebending
Rebending or straightening bars is a common practice on-site.
Instructions on a suitable procedure should be given in the structural
drawings, even if it is known that such bending will not be needed. A
tolerance on straightness should also be provided; an axial deviation of
the centre line of one bar diameter along with a directional change of 5O
is considered acceptable.

Any on-site cold bending should only be done with a proper bar bending
tool. Pulling the bar against the edge of the concrete, hitting the bar with a
sledge hammer or using a length of pipe damages the surface of the
reinforcement, reduces its ductility, can cause breakage of the steel and
may cause premature failure of the concrete element.

When reinforcement is bent about a curve smaller than the recommended


minimum pin diameter, or bent against an edge, the steel is excessively
strained on the compression and tension faces. An attempt to straighten a
bar bent too tightly may lead to bar failure.

The Smorgon ARC Reinforcement Handbook Page 19


Reinforcing Bar Processing

On-Site Bending of Reinforcing Mesh


Site bending of mesh is usually done by poking a bar through the opening
in the mesh, then rolling the bar over to bend the mesh about a cross
wire. This is then repeated every two or three openings for the width of the
mesh. This practice is not recommended as it bends the reinforcement
about an effective pin size of one bar diameter, with the cross wire acting
as the bending pin. This is well below the three diameter pin size required
for Ductility Class L bars or the four diameter pin size required for Ductility
Class N bars in AS3600-2001, Clause 19.2.3.2. On-site bending of
reinforcement also tends to be very variable and inaccurate, usually
outside construction tolerances.

Final Advice on Mistreatment of Steel


It cannot be stated enough that steel cannot be expected to perform its
proper function if it has been mistreated by excessive tight bending or by
overheating. Site bending, welding or heating of bars should only be
permitted under very strict and competent supervision. A detailed job
procedure and quality control system should be employed for site
bending, welding or heating of bars.

6.3 Welding Reinforcement


Welding of reinforcement must comply with AS1554.3, Structural Steel
Welding, Part 3: Welding of Reinforcing Steel.

In general, preheat is not required for welding reinforcing steel. The heat
input should be controlled to avoid changing the metallurgical properties of
the steel and hydrogen controlled electrodes should be used.

Tack welds require a minimum 4 mm throat and a minimum length equal


to the diameter of the smaller bar being welded. AS3600-2001 Clause
13.2.1 (f) prohibits welds within 3 db from any part of the reinforcement
that has been bent and re-straightened. AS1554.3 Clause 1.7.3 (b)
restricts straightening or bending of a bar within 75 mm of a weld location.

Special care is required when welding galvanised reinforcement. Welding


Figure 36: Bars spliced with a mechanical coupler galvanised reinforcement should be avoided.

6.4 Mechanical Splices


There is a wide range of mechanical splices available for reinforcing bar in
Australia. The most common types of splices are the Ancon CCL Bartec
coupler and the Erico Lenton coupler.

AS3600-2001 does not have any rules governing the adequacy of


mechanical splices. Factors that should be considered when selecting a
coupler are:

• Slip – Most international codes limit the slip in the coupler to 0.1 mm at
70% of the yield load. This is to restrict the width of cracking at the
coupler location. Typically cracks in concrete are limited to 0.3 mm
width. If the coupler slips 0.1 mm under load, then the crack at the
surface of the concrete will be greater than 0.1 mm. Shrinkage, creep
Figure 37: Bartec thread and flexural cracking will add to the crack width that has resulted from
slip within the coupler.

• Uniform Elongation – To maintain the ductility of the structure, the


coupling system must also be ductile. Although a uniform elongation
greater than 5% would be desirable very few coupling systems can
achieve this. The ISO standard is a minimum uniform elongation of 3.5%

Page 20 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar Processing

Figure 38: Lenton thread

for mechanical splices. Care should be taken when locating couplers


to ensure the ductility of the structure is not reduced below the design
requirements.

• Minimum Yield Stress – The coupler system should be strong enough


to develop the characteristic yield stress of the reinforcement, typically
500 MPa. Be aware that actual yield stresses for D500N reinforcement
can range from 500 MPa to 650 MPa.

• Tensile Strength / Yield Stress Ratio – To maintain the ductility of the


structure, the Tensile Strength / Yield Stress Ratio of the coupler
system should not be less than 1.08, measured for actual stresses
across the full range of yield stresses (500 MPa to 650 MPa for a
D500N bar).

• Dynamic Capacity – In areas subjected to dynamic loads, a coupler


system that has been tested for cyclic loading and fatigue should be
used. The ISO and ICBO codes have good cyclic and fatigue testing
programs.

When selecting the grade of reinforcement, whether it is L or N,


assumptions are made about the design method and the structure’s
performance. It is important that the designer ensures the coupler system
selected is able to perform in a manner that is consistent with the
reinforcement design.

The Smorgon ARC Reinforcement Handbook Page 21


7.0 Rust and Protective Coatings

Rust and Reinforcement


Accepting or rejecting a bar or fabric with visible rust is a decision often
facing site engineers and superintendents. The criteria for acceptance or
rejection is usually not known by the decision maker. When does the
reinforcement have excessive rust that is detrimental to its performance?

A moderate coating of rust is not detrimental to the reinforcement and can


actually improve its bond strength. The improved bond due to moderate
rusting is well documented and is included in the commentary to AS3600.
Rust usually appears first at the bends of reinforcement, where the steel
has undergone some cold working.

Rust is only excessive if the cross-sectional area of the steel is reduced


below the minimum tolerance permitted for a bar or wire. To check the
area, take a rusty piece of steel, wire brush it to remove the rust, measure
its length and then weigh it. The area is calculated taking the density of
steel as 7850 kg/m3.

Rust due to exposure to salt water can be detrimental to the


reinforcement. The chloride ions in the salt water cause pitting of the steel,
and this reinforcement should not be used without rigorous testing of yield
stress, uniform elongation, tensile strength and cross-sectional properties.
Even reinforcement that has only had mild exposure to salt water should
be washed prior to use to remove any salt from the steel surface.

Reinforcement that has been fixed for some time before concrete
placement may, after rain, show lines of iron oxide (rust) on the forms. If
the forms are not cleaned and the staining removed prior to pouring the
concrete a rusty looking line will be visible on the concrete soffit. This is an
aesthetic problem, not a structural or durability problem.

Mill Scale
Mill scale on hot rolled products, in the levels found on Australian
produced reinforcement, is not detrimental to the reinforcement. Wire and
fabric are free of mill scale.

Types of Coating
The two principal protective coatings are hot dipped galvanising and
fusion-bonded epoxy coating. The former is generally available in most
major centres, although there may be a physical limit to the size of the zinc
bath in some localities. Fusion bonded epoxy coating in Australia is not
easily obtainable.

The note to AS3600 Clause 4.3.1 General, says, “a protective surface


coating (to the concrete) may be taken into account in the assessment of
the exposure classification”. AS3600 does not allow any reduction on
cover when a protective coating is added to the reinforcement.

Hot Dip Galvanising of Reinforcement


Galvanising of reinforcement is to AS4680 and AS4534. AS3600-2001
requires galvanised bars to be bent about a 5 db pin if 16 mm diameter or
less and an 8 db pin for larger bars. This is regardless of whether the bar is
to be galvanised before or after bending.

Page 22 The Smorgon ARC Reinforcement Handbook


Rust and Protective Coatings
The Galvanising Process
1. Preparation – Mill scale, rust, oil and dirt are removed from the
reinforcement. It is then placed in a pickling bath of hydrochloric
acid. After pickling the reinforcement is rinsed.

2. Fluxing – The pickled reinforcement is immersed in a solution


of zinc ammonia chloride at about 65O C.

3. Galvanising – The reinforcement is immersed into a molten zinc


bath at 445O C to 465O C. The molten zinc reacts with the steel
to form layers of zinc – iron alloys.

The galvanised coating of zinc improves the reinforcement’s corrosion


resistance. The zinc forms a sacrificial coating about the reinforcement.
Minor breaks in the coating, such as may be caused by bending of the
reinforcement, are not detrimental to the corrosion protection offered by
the galvanising.

Embrittlement of reinforcement is rare in steels below 1000 MPa, however


it must be considered when galvanising reinforcement. The major factors
affecting embrittlement of reinforcement are the length of time the steel is
in the pickling bath, the heat of the galvanising process and the presence
of cold working, particularly at bend locations. A detailed explanation of
this is given in the May 1994 edition of Corrosion Management, “Designing
for Galvanizing – Avoiding Embrittlement”.

Galvanised reinforcement should not be in contact with stainless steel,


aluminium or copper and their alloys as the zinc corrodes preferentially
to these metals.

More detailed information regarding hot dip galvanising can be obtained


from the Galvanizers Association of Australia. Their publication, “After-
Fabrication Hot Dip Galvanizing”, provides an excellent overview of this
subject.

Galvanising of Reinforcement – AS/NZS4680:1999


AS/NZS4680, Hot-Dipped Galvanised Coatings on Fabricated Ferrous
Articles, includes provisions for galvanising wire, bar and fabric in Section
5 General Articles. As a general requirement for reinforcement, the minimum
average coating is 600 grams per square metre, or approximately 0.085 mm
thick.

Limits for the molten metal and finished appearance are given, together
with test requirements for coating mass and adherence.

It should be noted that a smooth finish on reinforcing products cannot be


expected. The deformation on the surface of bars does not allow a
particularly pleasing appearance but this does not detract from the overall
performance. The steel should be reasonably free of dags of surplus zinc.

Appendix D of AS/NZS4680, Properties of the Steel to be Coated, which


can affect or be affected by hot-dip galvanising, gives an excellent
overview of steel embrittlement. Reinforcement that has been galvanised
should not be bent on pin diameters smaller than those given in
AS3600:2001, should not be heated or bent on site and should not be
welded.

Appendix E of AS/NZS4680, Renovation of Damaged or Uncoated Areas,


states that exposed steel situated within 1 mm of a substantial zinc layer,
should receive sacrificial protection. This implies that cut ends of pre-
galvanised bar or fabric should be repaired.

The Smorgon ARC Reinforcement Handbook Page 23


Rust and Protective Coatings

Galvanising of Welded Wire Fabric - AS/NZS4534:1998


AS/NZS4534, Zinc and Zinc/Aluminium-Alloy Coatings on Steel Wire
addresses galvanising of welded wire fabric. As a general requirement for
reinforcement fabric, the minimum average coating is 610 grams per
square metre, or approximately 0.085 mm thick.

Appendix C of AS/NZS4534 gives an overview of hydrogen embrittlement.


Appendix F is a comprehensive guide to coating thickness selection for
corrosion protection.

Epoxy Coating
An excellent reference is ‘The Epoxy Coated Rebar CD-Rom’, produced
by the Concrete Reinforcing Steel Institute, 9333 North Plum Tree Grove,
Schaumber, IL, 60173, USA.

Figure 39: Galvanised reinforcement

Page 24 The Smorgon ARC Reinforcement Handbook


8.0 Quality Assurance and Quality Control

Applicable Standards
AS/NZS ISO9001:2000 Quality Management Systems provides the basis
for steel industry QA systems. Explanations of the application of these
standards is beyond the scope of this handbook.

Quality Assurance for Steel and Wire


In supplying reinforcement, there are two separate levels of quality
assurance.

Firstly, the quality of the raw material (steel bar and wire) is controlled
during steel making and wire drawing. These materials are covered by test
certificates or certificates of compliance with the appropriate standards.
Each bundle or coil is tagged and identified by a serial number, from which
the heat number, date of production and other details can be obtained.
Delivery dockets show that the material is ‘deemed to comply’ with the
relevant standard, indicating that the steel maker has a certified Quality
Assurance programme in place.

On arrival at the reinforcing steel supplier’s works the material is placed in


racks from which it is withdrawn as needed.

Quench and self tempered bars and micro alloy bars are not segregated
because they are both Grade D500N to AS4671.

Secondly, accuracy of fabrication must be assured by the reinforcement


supplier to comply with AS3600 as well as any relevant parts of AS4671.

Methods of Demonstrating Compliance

Figure 40: Testing the chemical and physical AS4671 has an Appendix A which sets out the various methods by which
properties of the steel in the molten state a manufacturer can show compliance with the Standard.

These methods are described in the Standard as:

(a) Assessment by means of statistical sampling.

(b) The use of a product certification scheme.

(c) Assurance using the acceptability of the supplier’s quality system.

(d) Other such means proposed by the manufacturer or supplier and


acceptable to the customer.

Traceability of Heat Numbers for Bars


Quality assurance procedures have removed the need for traceability to
heat numbers.

Whilst large structural steel sections and plate can be readily identified
back to their heat, bar and wire cannot. The latter have one big advantage
- if there is any doubt about quality, a sample length can be taken and
tested very easily.

Each heat of steel produces about 80 to 100 tonnes of steel, which is cast
into billets of approximately 1.5 tonnes. The chemical composition of the
heat is obtained by spectroscopic methods and is documented as a
whole.

Each billet is rolled to one size producing 1.5 tonnes so that if 4 tonne
bundles are ordered, more than one billet is required. More than one heat
may be involved, but this is unusual. After rolling, the finished bar is tensile
and bend tested, and the results documented.

The Smorgon ARC Reinforcement Handbook Page 25


Quality Assurance and Quality Control
Certificates of compliance with AS4671 are
received from the steel maker close to the time
when each bundle of steel is delivered. These are
cross-checked with the tag on the bundle which
remains there until the bundle is opened and steel
removed to the cutting bench.

After cutting, an individual bar is no longer


traceable back to its originating heat or bundle.
Nevertheless, a bar on site can be related back to
a group of bundles of stock material released to
production on a specified date, but a direct link to
a specific bundle is not available.

Traceability of Wire and Mesh


In each step of the manufacturing process there
are several test procedures which must be
followed and each one applies to the product
manufactured by that operation.

Wire is drawn from coiled rod which in turn has


been rolled from the original billet.
Figure 41: Testing reinforcing steel in
Rather than attempt full traceability for wire production, the wire making
Smorgon ARC’S NATA registered laboratory
process is covered by a certificate stating that the converted material
complies with AS4671. This certificate is issued by the wire maker.

After welding the wire to make fabric, an additional assurance is given by


the fabric manufacturer that the fabric complies with AS4671.

It can be seen that traceability of wires in a sheet of fabric is not practical.


A standard 2.4 metre wide sheet contains up to 25 individual longitudinal
wires and 30 transverse wires, each coming from a separate coil weighing
a tonne or more.

Traceability of Material
On-site traceability is the responsibility of the contractor. When
performance assurance is given for the material, on-site traceability should
not be required.

Page 26 The Smorgon ARC Reinforcement Handbook


9.0 Tolerance on Bar Manufacture

Tolerances on Bar Manufacture (AS4671)

(a) Chemical composition


A cast analysis and a product analysis is required. See AS4671 Table 1.

Table 4: Carbon content of reinforcing steel


An upper limit is given for the cast analysis. This is made while the steel
is in a liquid form and therefore while the composition of the steel can
be adjusted.
Due to changes during casting of billets and subsequent rolling into the
finished product, slightly higher limits are allowed for the product analysis.

(b) Drawing/Rolling tolerances


Mass/unit length ± 4.5%

(c) On bar length (bars AS4671)


L≤7m + 0, - 40 mm
L > 7 but < 12 m + 40, - 40 mm
L ≥ 12 m + 60, - 40 mm

(d) Straightness on length L, in units of L


Bar sizes ≤16 mm L/50
Bar sizes ≥ 20 mm L/100

(e) Deformations
There are no tolerances given for deformations. Values are maximum or
minimum. See Clause 7.4 and Appendix C3 of AS4671.

(f) Manufacturer and mill identification


The distance between the identifying marks (deformed bars), equals the
circumference of the rolls which have the deformations cut into them. Identifiers
are usually on one side only. They identify the steel maker and the rolling mill.

(g) Mesh tolerance between adjacent wires


Distance ±0.075 x pitch

(h) Mesh sheet size


Dimension ≤ 6000 mm ±40 mm
Dimension L > 6000 mm ±0.007 L

The Smorgon ARC Reinforcement Handbook Page 27


10.0 Information from AS3600-2001

Extracts from AS3600-2001 must be read in conjunction with the latest


approved edition of the complete Standard. They are reproduced here, in
boxes, for the reader’s guidance purposes only.

Although there are many clauses which refer to reinforcing steel, the
following references are those most applicable to its supply and fabrication.

1.1.2 Application. Lists applicable reinforcing steels.

1.4 Information on Drawings. Lists the information expected to be


given.

4.10 Requirements for cover to reinforcing steel and tendons.


These values are for durability.

Section 5 Design for fire resistance. Additional cover may be required


for this purpose.

6.2 Properties of reinforcement.

7.6.8.3 Approval for Class L reinforcement.

Section 13 Stress development and splicing of reinforcement and tendons.


See sections 11 and 12.

19.2 Material and construction requirements for reinforcing steel.

19.5 Tolerances for structures and members.

10.1 Clause 1.1.2 Application

The Standard also applies to reinforcing steels complying with-


(a) AS1302, or having a yield strength (fsy) of 500 MPa and Ductility Class N in accordance with AS/NZS4671.
These reinforcing materials may be used, without restriction, in all applications referred to in this Standard; and
(b) AS1303 or AS1304, or having a yield strength (fsy) of 500 MPa and Ductility Class L in accordance with
AS/NZS 4671. These reinforcing materials shall not be used in any situation where the reinforcement, or
member, is expected to undergo large deformation under strength limit state conditions.

NOTE: The use of Ductility Class L reinforcement is further limited by other clauses within this Standard.

AS1302, AS1303 and AS1304 will be withdrawn on 1 April 2002.

Design methods such as Moment Redistribution and Plastic Hinge Design


assume large deformations and as such should not be used with Ductility
Class L reinforcement.

10.2 Clause 1.4 Information on Drawings


The information listed in these extracts is required by all sections of the
construction chain from the designing and checking engineers, draftsmen,
quantity surveyors and reinforcement schedulers, through to steel fixers
and site supervisors. Without these details quality assurance will break
down. Poorly detailed drawings result in increased construction costs and
site delays as time is lost determining the requirements for the structure.

Page 28 The Smorgon ARC Reinforcement Handbook


Information from AS3600-2001

1.4.1 Design Data


The following design data shall be shown in the drawings:
(a) Reference number and date of issue of applicable design Standards
(b) Live loads used in design
(c) Exposure classification for durability
(d) Fire-resistance rating, if applicable
(e) Class and where appropriate, grade designation of concrete
(f) Grade, ductility class and type of reinforcement and grade and type tendons
(g) The appropriate earthquake design category, acceleration coefficient and site factor determined from AS1170.4
1.4.2 Design Details
The drawings or specification for concrete members and structures should include, as appropriate, the following:
(a) The shape and size of each member
(b) The finish and method of control for unformed surfaces
(c) Class of formwork in accordance with AS 3610 for the surface finish specified
(d) The size, quantity and location of all reinforcement, tendons and structural fixings, and the cover to each
(e) Any required properties of the concrete
(f) The curing procedure
(g) The force required in each tendon, the maximum jacking force to be applied and the order in which tendons are to be stressed
(h) The location and details of planned construction or movement joints, connections and splices, and the method to be used
for their protection
(i) The minimum period of time before stripping of forms and removal of shores
(j) Any constraint on construction assumed in the design
(k) Any other requirements

Examples of preferred specifications in a drawing:


RF92 The style of standard D500L fabric covering the whole
area of a slab. There is no need to specify either the
number of sheets required to provide full coverage or the
lap dimension.

8-N28 The number (8) of 28 mm deformed bars of Grade


D500N in a layer or cross-section.

20-N16-200 The number (20) of 16 mm deformed bars of Grade


D500N spaced at 200 mm centres across the width
of a slab.

6-R10-150-T1 The number (6) of 10 mm plain round bars of grade


R250N used for fitments of shape T1 and spaced at
150 mm centres.

ARCN102 R500N mesh with 10 mm nominal diameter wires at 200


mm centres each way covering the whole area of a slab.
There is no need to specify either the number of sheets
required to provide full coverage or the lap dimension.

10.3 Cover to Reinforcing Steel


According to AS3600, ‘cover is the distance between the outside of the
reinforcing steel or tendons and the nearest permanent surface of the
member, excluding any surface finish. Unless otherwise noted, the
tolerances on position of reinforcement and tendons given in Clause
19.5.3 apply’.

The two primary purposes of cover are durability and fire resistance.
As a general rule, cover is selected from an appropriate table but there
are several cases where additional cross checks are required.

A secondary reason for adequate cover is to ensure that the stresses in


steel and concrete can be transferred, one to another, by bond. These
actions are called stress development and anchorage. The cover required
for these purposes is measured not to the nearest bar, but to the bar
whose stress is being developed.

The Smorgon ARC Reinforcement Handbook Page 29


Information from AS3600-2001

10.4 Section 4 Cover for Durability


In AS3600, durability of the structure is very much related to individual
surfaces of a member and to the compressive strength of the concrete.

For one member to have the same durability resistance as another


member, AS3600 requires the same cover to the nearest reinforcement or
tendon, but the method of selecting the exposure classification and the
appropriate concrete strength requires a number of factors to be
considered.

The following information must be obtained before cover for corrosion


protection is determined:

(a) the most severe Exposure Classification for durability (A1 to U);

(b) the characteristic compressive strength of the concrete ƒ’c for the most
severe situation for use in strength, serviceability and durability design,
allowing for abrasion and freeze/thaw conditions;

(c) the degree of compaction; and

(d) the type of formwork.

Cover for Concrete Placement


Clause 4.10.2 limits the minimum cover, in the absence of a detailed
analysis, to either the reinforcement bar diameter or the maximum nominal
aggregate size, whichever is the larger.

Combined Table from Clauses 4.3, 4.4, 4.5, 4.6, 4.10.3.2 and 4.10.3.3, for
the selection of minimum cover for corrosion resistance of reinforcing and
prestressing steel.

Table 5: Cover for corrosion resistance


The above table does not consider abrasion, freezing and thawing, rigid
formwork or spun or rolled members.

Page 30 The Smorgon ARC Reinforcement Handbook


Information from AS3600-2001

10.5 Section 5 Cover for Fire Resistance


During the course of a fire, temperatures in excess of about 200ºC reduce
the strength of both steel and concrete. Fortunately the insulation
properties of concrete are greater than those of steel, and the concrete
cover is the best and cheapest method of increasing the fire resistance of
structures.

The cover for fire resistance depends on:

(a) the type of member;

(b) how that member carries the loads imposed on it;

(c) whether or not it is continuous (flexurally or structurally) with other


members; and

(d) the fire resistance period it provides.

Concrete strength is not taken into account when selecting cover for fire
resistance. Similarly, the effects of fire need only be considered for
members which are required, by Building Regulations or through other
Authorities, to attain a specified fire resistance level. In certain structures
which have a high exposure classification, due to proximity with hazardous
materials for example, resistance to fire may take precedence over all
other factors.

The Smorgon ARC Reinforcement Handbook Page 31


Information from AS3600-2001

10.6 Clause 6.2 Properties of Reinforcement

6.2.1 Strength and Ductility


The yield strength of reinforcement (fsy) shall be taken as not greater than the value specified in Table 6.2.1 for
the appropriate type of reinforcement (see also Clause 19.2.1.1).
The ductility of the reinforcement shall be characterized by its uniform strain (Esu) and tensile-to-yield stress
ratio and designated as low (L) or normal (N) as given in Table 6.2.1. Values of these parameters for each
ductility class shall comply with AS/NZS 4671.
Reinforcement types complying with AS 1302 may be considered to be Class N without any additional testing
requirements. Testing is required for reinforcement types complying with AS 1303 and AS 1304 to demonstrate
that they satisfy the requirements for Class L steels specified in AS/NZS 4671.

Reinforcement Yield Stress Ductility


Type Designation Grade (fsy) Mpa Class
Bar –
Plain to AS 1302 250R (fitments only) 250 N
Deformed to AS 1302 250S 250 N
Deformed to AS 1302 400Y 400 N
Wire, plain or deformed to AS 1303 450W (fitments only) 450 L
Welded wire mesh
Plain or deformed to AS 1304 450F 450 L
Bar deformed to AS/NZS 4671 D500L (fitments only) 500 L
D500N 500 N
Welded wire mesh, plain, deformed and indented to AS/NZS D500L 500 L
4671 D500N 500 N

NOTE: Reference should be made to AS/NZS 4671 for explanation to designations applying to 500 MPa steels.

Plain round bars are manufactured in accordance with AS3679, however


they are deemed to comply with AS4671 and should be specified by this
Standard.

6.2.2 Modulus of elasticity


The modulus of elasticity of reinforcement (Es) for all stress values not greater than the yield strength (fsy) may
be either:
(a) taken as equal to 200 x 103 MPa; or
(b) determined by test.
6.2.3 Stress-strain curves
A stress-strain curve for reinforcement may be either:
(a) assumed to be of a form defined by recognized simplified equations; or
(b) determined from suitable test data.
6.2.4 Coefficient of thermal expansion
The coefficient of thermal expansion of reinforcement may be either:
(a) taken as equal to 12 x 10-6/ºC; or
(b) determined from suitable test data.

Page 32 The Smorgon ARC Reinforcement Handbook


Information from AS3600-2001

10.7 Clause 7.6.8.3 Class L Reinforcement

7.6.8.3 Approval for Class L Reinforcement


Where Ductility Class L reinforcement is used, moment redistribution shall not be permitted unless an analysis,
as specified in Clause 7.6.8.1, is undertaken.

Particular attention should be given to the final paragraph of Clause 7.6.8.1.


Special consideration shall be given to the detrimental effects that significant
relative foundation movements can have on the strength of continuous
beams and slabs incorporating Ductility Class L reinforcing steel (low
ductility) as the main reinforcement. The designer should also consider
other potentially detrimental effects such as differential shortening in
columns of high rise buildings and differential deflections of adjacent
beams.

10.8 Clause 19.2 Material and Construction Requirements for Reinforcing Steel

19.2.1 Materials
19.2.1.1 Reinforcement
Reinforcement shall be deformed bars Class N bars, or Class L or Class N welded wire mesh (plain or
deformed), with a yield stress of up to 500 MPa, except that fitments may be manufactured from Class L wire
or bar, or plain Class N bar.
All reinforcement shall comply with AS1302, AS1303, AS1304 or AS/NZS 4671 as appropriate.

Dowel bars for pavements are not specifically mentioned in AS3600-2001.


They are generally cut from Grade R250N plain round bars.

Designs using fibre reinforcement, either steel or plastic, is not covered by


AS3600-2001.

Class L reinforcement should not be used as the main reinforcement. If a


designer wishes to use L grade main reinforcement, they must ensure the
design does not require the reinforcement or the member to undergo large
deformation or large rotation, a relatively non-ductile failure can be tolerated
and there are no foreseeable causes of overload to the reinforcement or
member, then Ductility Class L reinforcement will perform satisfactorily.
Ductility of the bar is an issue after the bar has yielded and permanent
plastic deformation of the bar has occurred.

19.2.1.2 Protective Coatings


A protective coating may be applied to reinforcement provided that such coating does not reduce the
properties of the reinforcement below those assumed in the design.
19.2.2 Fabrication
(a) Reinforcement shall be fabricated to the shape and dimensions shown in the drawings and within the
following tolerances-
(i) On any overall dimension for bars and mesh except where used as a fitment.
(A) For lengths up to 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–25, +0 mm.
(B) For lengths over 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–40, +0 mm.
(ii) On any overall dimension of bars or mesh used as a fitment.
(A) For deformed bars and mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–15, +0 mm.
(B) For plain round bars and wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .– 10, +0 mm.

The Smorgon ARC Reinforcement Handbook Page 33


Information from AS3600-2001

(iii) On the overall offset dimension of a cranked column bar . . . . . . . . . . . . . . . . . . . .–0, +10 mm.
(iv) For the sawn or machined end of a straight bar intended for use as an end-bearing splice,
the angular deviation from square, measured in relation to the end 300 mm,
shall be within . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2º.
(b) Bending of reinforcement shall comply with Clause 19.2.3.
(c) Welding if required shall comply with AS 1554.3. Tack welding not complying with that Standard shall not
be used.

19.2.3 Bending
19.2.3.1 General

Reinforcement may be bent either:

(a) Cold, by the application of a force around a pin of diameter complying with Clause 19.2.3.2, so as
to avoid impact loading of the bar and mechanical damage to the surface of the bar; or

(b) Hot, provided that:

(i) The steel must be heated uniformly through and beyond the portion of be bent;

(ii) The temperature of the steel must not be allowed to exceed 600º C,

(iii) The bar must not be cooled by quenching, and

(iv) If during heating the temperature of the bar exceeds 450º C, the design yield strength of the
steel after bending shall be taken as 250 MPa.

The temperature can be controlled by thermal crayons, etc. Quenching


would totally alter the crystal structure.

Reinforcement which has been bent and subsequently straightened or bent in the reverse direction shall not
be bent again within 20 bar diameters of the previous bend.

This distance is intended to keep cold working from the original bending
zone separated from additional bending.

Reinforcement partially embedded in concrete may be field bent (ie, in situ) provided that the bending
complies with items (a) or (b) above, and the bond of the embedded portion is not impaired thereby.

The greatest need encountered with this bending is to control the bend
curvature without notching the bar, and to prevent spalling of the concrete,
particularly in thin members. It is very rare for a site bent bar to be bent
correctly, with bars often being pulled out against the edge of the concrete
or bent with a pipe. These methods of bending severely notch the bar and
can cause bar breakage.

19.2.3.2 Internal diameter of bends or hooks

The nominal internal diameter of a reinforcement bend or hook shall be taken as the external diameter of the
pin around which the reinforcement is bent. The diameter of the pin shall be not less than the value determined
from the following as appropriate:

(A) For fitments of –

(i) Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3db


(ii) Grade 250 bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3db; and
(iii) Grade 400 and 500 bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4db

Clause 8.2.12.4 requires a 4 db pin be used for all beam ligatures

Page 34 The Smorgon ARC Reinforcement Handbook


Information from AS3600-2001

(b) For reinforcement, other than specified in Items (c) and (d) below, of any grade . . . . . . . . . . . . . . . 5db

(c) For reinforcement, in which the bend is intended to be subsequently straightened or rebent, of
(i) 16 mm diameter or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4db;
(ii) 20 mm diameter or 24 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5db; and
(iii) 28 mm diameter or greater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6db.

Any such straightening or rebending shall be clearly specified or shown in the drawings.

(d) For reinforcement that is epoxy-coated or galvanized, either before or after bending, of
(i) 16 mm diameter or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5db;
(ii) 20 mm diameter or greater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8db.

19.2.4 Surface Condition


At the time concrete is placed, the surface condition of reinforcement shall be such as not to impair its bond
to the concrete or it’s performance in the member. The presence of millscale or surface rust shall not be cause
for rejection of reinforcement under this clause.

Rust and millscale, of themselves, do not adversely affect bond. Dirt and
oil are much worse.

10.9 Clause 19.5.3 Tolerance on Position of Reinforcement


AS3600 Clause 19.5.3, provides the basis for reinforcement placing
tolerances. The wording differs from AS3600.

The position of reinforcement and tendons may differ from that specified
as follows where a ‘+’ value indicates that the cover may be greater than
specified and a ‘-’ indicates the cover may be less.

(a) Where the position (mm) is controlled by the minimum design cover, eg,
all round ties and stirrups, the cover at ends and from surfaces in walls
and slabs.

(i) Beam, slab, column, wall -5, + 10 mm

(ii) Slab on ground -10, + 20 mm

(iii) Footing cast in ground -20, + 40 mm

(b) Where the position is not controlled by the minimum design cover, for
example on-

(i) The position of the ends of a main bar 50 mm

(ii) The spacing of parallel bars in a slab or wall, or spacing of fitments


10% of specified spacing or 15 mm, whichever is greater

The Smorgon ARC Reinforcement Handbook Page 35


11.0 Reinforcing Bar
11.1 Bar General Information

Hot Rolled, High Strength Deformed Bars of Grade D500N

Both quench and self tempered and micro-alloy reinforcing bars are
classified as Grade D500N and no distinction is made between them for
supply purposes. Each steel-maker identifies their rolling mill with its
individual surface mark.

Smorgon ARC’s reinforcement is Australian made from 100% recycled


steel. The Smorgon mill mark is a guarantee of quality. Engineers can rely
on the Smorgon mill mark to ensure the reinforcement on their project
Figure 42: Smorgon micro-alloy mill mark complies to Australian Standards.

Table 6: Basic information about grade D500N deformed bars - AS4671


Notes:

1. The calculated area of a deformed bar is calculated from the bar size, in
mm, as if it was a circle.

2. The nominal area of a deformed bar is the calculated area, rounded to


two significant places, and should be used in all design calculations and
for routine testing for quality control.

3. The calculated mass is the calculated area multiplied by 0.0078


kg/mm2/m (7850kg/m3) taken to four decimal places to assure
accuracy for quantities measured by length but sold by the tonne. The
actual area of a test bar (measured mass of a sample 0.00785) should
be used only for fundamental research.

Figure 43: Smorgon QST mill mark 4. The nominal mass includes the rolling margin, based on the calculated
mass plus 2.5%, and is used for calculating the mass of material sold in
all commercial transactions.

Cold Rolled, High Strength Deformed Bars of Grade D500L


Cold rolled bars are typically Ductility Class L. D500L bars are used as
fitments and in residential slabs on ground. AS2870 currently permits
D500L main bars, however, this is currently under review.

Table 7: Basic information about grade D500L


deformed bars - AS4671
Page 36 The Smorgon ARC Reinforcement Handbook
Reinforcing Bar

Bar Size Nominal Area Calculated Area Calculated Mass Nominal Mass
mm mm2 mm2 kg/m kg/m

R6.5 30 33.2 0.2605 0.2670


R10 80 78.5 0.6165 0.6320
Table 8: Basic information about plain round grade R250N bars for use as fitments only - AS4671

Notes:

1. Availability of these sizes can depend on local practice throughout


Australia. They are produced from coiled rod of grade 250 MPa, or
from coiled wire of grade 500 MPa. Specify your required strength.

2. All values given in the above table are for 6.5 mm and 10 mm coiled rods.

3. Plain round bars for dowel bars are available in larger sizes to AS3679,
Grade 250. These sizes are: R12, R16, R20, R24, R27, R33 and R36,
but the full range may not be available from stock at all times.

The Smorgon ARC Reinforcement Handbook Page 37


Reinforcing Bar

Bar Size N12 N16 N20 N24 N28 N32 N36 N40 N50
No. mm2 mm2 mm2 mm2 mm2 mm2 mm2 Mm2 mm2

1 110 200 310 450 620 800 1020 1260 1960


2 220 400 620 900 1240 1600 2040 2520 3920
3 330 600 930 1350 1860 2400 3060 3780 5880
4 440 800 1240 1800 2480 3200 4080 5040 7840

5 550 1000 1550 2250 3100 4000 5100 6300 9800


6 660 1200 1860 2700 3720 4800 6120 7560 11760
7 770 1400 2170 3150 4340 5600 7140 8820 13720
8 880 1600 2480 3600 4960 6400 8160 10080 15680
9 990 1800 2790 4050 5580 7200 9180 11340 17640

10 1100 2000 3100 4500 6200 8000 10200 12600 19600


11 1210 2200 3410 4950 6820 8800 11220 13860 21560
12 1320 2400 3720 5400 7440 9600 12240 15120 23520
13 1430 2600 4030 5850 8060 10400 13260 16380 25480
14 1540 2800 4340 6300 8680 11200 14280 17640 27440

15 1650 3000 4650 6750 9300 12000 15300 18900 29400


16 1760 3200 4960 7200 9920 12800 16320 20160 31360
17 1870 3400 5270 7650 10540 13600 17340 21420 33320
18 1980 3600 5580 8100 11160 14400 18360 22680 35280
19 2090 3800 5890 8550 11780 1520 19380 23940 37240

20 2200 4000 6200 9000 12400 16000 20400 25200 39200


21 2310 4200 6510 9450 13020 116800 21420 26460 41160
22 2420 4400 6820 9900 13640 17600 22440 27720 43120
23 2530 4600 7130 10350 14260 18400 23460 28980 45080
24 2640 4800 7440 10800 14880 19200 24480 30240 47040

25 2750 5000 7750 11250 15500 20000 25500 31500 49000


26 2860 5200 8060 11700 16120 20800 26520 32760 50960
27 2970 5400 8370 12150 16740 21600 27540 34020 52920
28 3080 5600 8680 12600 17360 22400 28560 35280 54880
29 3190 5800 8990 13050 17980 23200 29580 36540 56840

30 3300 6000 9300 13500 18600 24000 30600 37800 58800


Table 9: Design cross-sectional area of deformed bars

Notes:
1. This table would generally be used for the design of beams, columns and narrow footings, etc.

2. Before selecting the number of bars in one layer of a beam or column, check that they can fit across the member
width. The table below allows a quick assessment of spacing per bar.

3. Sizes N12 and N16 are available in as-rolled straight lengths, or as straightened lengths from coil. They may be
either quench and self tempered steel or micro alloy steel.

4. Sizes N40 and D450N50 are micro alloy bars and are available to special order only.

Bar Size N12 N16 N20 N24 N28 N32 N36 N40 N50

Space/bar 40 50 60 70 90 100 110 160 200


Table 10: Estimation of member minimum width to allow placement of concrete, mm/bar

To estimate the minimum width, allow the space for each bar.

Example: A beam with 4-N32 main bars, 30 mm cover to L10 fitments


Use a beam width of 4 x 100 = 400 mm

Page 38 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar

Table 11: Design cross-sectional area of deformed bars per metre width

Notes:
1. This table would generally be used for the design of slabs, walls and wide footings, etc.

2. Values for a centre-to-centre spacing of less than 4db is not provided because concrete is difficult to place and
splitting can occur along this plane. Note also that to apply AS3600 Clause 13.1.2.2, development lengths to
develop yield stress, the clear distance between bars must be not less than twice the cover to the bar being
designed.

3. Sizes N12 and N16 are available in as-rolled straight lengths, or as straightened lengths from coil. They may be
either quench and self tempered steel or micro alloy steel.

4. Sizes N40 and D450N50 are micro alloy bars and are available to special order only.

The Smorgon ARC Reinforcement Handbook Page 39


Reinforcing Bar

11.2 Bar Tension Lap and Anchorage


The most important factor for successful detailing of concrete structures is
ensuring that all stresses can be transferred from concrete to steel.

The information in this Smorgon ARC Handbook must be read in


conjunction with, and with a full understanding of, the principles of
reinforced concrete design and detailing given in AS3600.

In general, the parameters used to calculate the anchorage and lap


lengths are given with the tables. Where there are differences between our
Smorgon ARC Handbook and values obtained from other sources, the
user should check the parameters and recalculate as seen fit.

Lengths are based only on full yield stress of the steel. It is most unwise to
specify lap or anchorage lengths for a lower steel stress. For laps, this
practice is not permitted in AS3600-2001.

Anchorage and Development Length of Deformed Bars in Tension, L sy.t

The anchorage and lap length formula in AS3600, Clause 13.1.2, for a
straight piece of deformed bar in tension is –

Depth factor k1 x spacing factor k2 x bar yield stress fsy x bar area A b
L sy.t =
[(smaller of twice actual cover or clear spacing 2a) + bar size db] x √ (concrete strength fc)

This expression shows that:

• When the yield stress of the bar increases, the anchorage length
increases;

• When the clear spacing between adjacent parallel bars increases, the
anchorage length decreases;

• When the actual cover to the bar increases, the anchorage length
decreases;

• When a higher grade of concrete is used, the anchorage length will


decrease; and

• When the size (and therefore cross-sectional area) increases, the


anchorage length will also increase.

Calculations will show a dramatic reduction in the anchorage length when


cover or spacing is increased.

To assist with anchorage you can use a standard hook to provide end
anchorage of a bar where there is insufficient embedment for a straight
length to develop its design stress. A hook or cog reduces the
development length by 50%.

Page 40 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar

AS3600-2001 Clause 8.2.12.4 gives the requirements for fitment hooks.

Whether or not a bar should be anchored by a hook is a design matter.


It is not a scheduling decision, however the hook orientation must be such
that it will stay within the concrete with adequate cover and also satisfy
bending-pin requirements.

Figure 44: Bar embedment

Although hooked deformed bars can reduce the development length,


the hook can cause congestion of steel in critical areas and are a primary
source of rusting if they intrude into the cover concrete. Straight bars are
much easier to fix and protect. If there is so little room available for stress
development that hooks are required, it is probably a better solution to use
more bars of a smaller size with a consequential smaller development
length.

A fully stressed hook or cog will create a lateral splitting force on the
surrounding concrete, caused by the bearing stress between steel and
concrete at the bend. Hooked bars should never be used in thin sections,
say less than 12 bar diameters in the plane of the hook, or as top bars
in slabs.

A 90º bend which is longer than 10db overall, gives the same anchorage
as a 90O cog.

The Smorgon ARC Reinforcement Handbook Page 41


Tension Lap Length and Anchorage K1=1.00 5 K2=1.7
Slab and wall bars with more than 300 mm of concrete cast below the bar
Clear spacing is not less than 150 mm

Table 12: Slab and wall tension lap

Page 42 The Smorgon ARC Reinforcement Handbook


Tension Lap Length and Anchorage K1=1.25 K2=1.7
Slab and wall bars with more than 300 mm of concrete cast below the bar
Clear spacing is not less than 150 mm

Table 13: Slab and wall tension lap

The Smorgon ARC Reinforcement Handbook Page 43


Tension Lap Length and Anchorage K1=1.00 K2=2.2
Beam and column longitudinal bars with fitments
Less than 300 mm of concrete cast below the bar

Table 14: Beam and column bars with fitments

Page 44 The Smorgon ARC Reinforcement Handbook


Tension Lap Length and Anchorage K1=1.25 K2=2.2
Beam and column longitudinal bars with fitments
More than 300 mm of concrete cast below the bar.

Table 15: Beam and column bars with fitments

The Smorgon ARC Reinforcement Handbook Page 45


Tension Lap Length and Anchorage K1=1.00 K2=2.4
All other longitudinal bars
Less than 300 mm of concrete cast below the bar

Table 16: All other longitudinal bars


Page 46 The Smorgon ARC Reinforcement Handbook
Tension Lap Length and Anchorage K1=1.25 K2=2.4
All other longitudinal bars
More than 300 mm of concrete cast below the bar

Table 17: All other longitudinal bars

The Smorgon ARC Reinforcement Handbook Page 47


Reinforcing Bar

11.3 Bar Compression Lap Length and Anchorage


The lengths below rationalise the values given in AS3600. If both tension
and compression can act at different times on the same cross-section,
anchorage must be designed for the worst case situation.

If the factors given in Clause 13.1.4 for bundled bars are applied directly to
the compression development length given in Clause 13.1.3, they become
24db and 26.6db respectively. Bundled bars in compression are not
commonly used other than in the columns of very high buildings so that,
for practical use, all development lengths have been rounded up to 30 db.

For practical use also, the lap splice for a single bar in compression is
rounded up from 41 db (Clause 13.2.4) to 54 db for a bundled bar (Clause
13.2.5).

Lap splices are always based on full yield strength ƒsy. To permit other
values would create uncertainty in the mind of fixers and inspectors, and
would certainly require more work from detailers. AS3600-2001 Clause
13.2.4 does not allow reductions in compression lap lengths.

Table 18: Development and lengths for Compression Development Length for Single Bars, L sy.c
deformed bars
(Clause 13.1.3)
The formula for L sy.c given in Clause 13.1.3 is not dependent upon
concrete strengths, steel strengths, or on the width or depth of the
member. It is equal to 20 db.
Although it is not stated in Clause 13.1.3, the minimum cover and spacing
rules still apply. Compression causes splitting of the cover in a different
way to tensile forces. A realistic spacing is required to ensure concrete can
be consolidated properly. Encircling ties may also be advisable in zones of
heavy reinforcement.
Compression bars must not be hooked.
Compression Lap Splices for Single Bars (Clause 13.2.4)
For 500 MPa bars in a compression zone of the concrete, the lap length is
41 db. This is twice the compressive stress development length. This value
also applies to lap splice lengths for column bars.
Compression bars must not be hooked. This is not restricted to columns
and walls. It applies to all members.
Page 48 The Smorgon ARC Reinforcement Handbook
Reinforcing Bar

Where the concrete at the bottom of a beam over a column carries an


excessively large compression load, extra bars lapped for compressive
stress transfer will be required there.

Development Length of Bundled Bars in Compression


(Clauses 8.1.8.8, 10.7.2, 13.1.3, 13.1.4)
When two bars are tied together over their full length, to form a two-bar
bundle, an increase in development length is not required.

Three or four bars can be tied tightly together to form a bundle. Each bar
of the “unit” therefore presents a smaller surface in contact with the
surrounding concrete. This requires an increased development length for
bundled bars (Clauses 13.1.3, 13.1.4).

In beams, the bar cut-off point of each bar in a bundle must be staggered
by 40 db (Clause 8.1.8.8).

Compression Lap Splices for Bundled Bars (Clauses 13.2.1, 13.2.5)


Lap splicing of bundled bars is messy, complicated, uses excessive steel,
and causes overcrowding of the column area. These lap splices must be
avoided.

Wherever possible bundled bars should be spliced by end bearing


(no laps) or by mechanical splice because these give a simpler solution.

The values in the table also apply to an extra splice bar added to a bundle
which did not have a sawn-end preparation for an end-bearing splice. The
splice bar must be at least twice the lap length given above, and located
centrally about the section where the splice is.

The Smorgon ARC Reinforcement Handbook Page 49


Reinforcing Bar
11.4 Additional Information on Lap Splices

Deemed to Comply Values for Lap Splices of Main Bars in Tension

The table below provides tabulated values of development length and


lap splices in flexural members, provided the following rules are observed:

• The characteristic compressive strength of the concrete, f’c and the


corresponding value of the cover, c, are not less than given in the
table below.

• For slabs and walls, the clear distance between adjacent parallel bars
being designed, over the length in which they are considered to be
developing stress or over the lap length, must not be less than 150 mm.
This does not restrict the spacing to 150 mm over the remainder of
the length.

• For beams and columns, at least the minimum quantity of fitments


(stirrups, ties etc) must surround the main bars being designed, and
the clear distance between adjacent parallel bars must be at least
twice the cover given in the table.

Table 19: Minimum tensile development lengths


The minimum cover is from the surface of the concrete to the bar being
detailed.

Intermediate values of Lsy.t must not be interpolated. Alternative


combinations must be calculated from AS3600-2001.

For bars with more than 300 mm of concrete cast below them, the above
values must be increased by 25%.

Which Should be Used – A Tension Splice or a Compression Splice?


The simple answer is that if a bar can be in tension under one loading
condition, and change to compression under another (or vice versa), then
the splice must carry the “worst case” load. As examples, the above
situation can occur when the wind blows alternately from opposite
directions, or when trucks move across a bridge. It is suggested that
detailers incorporate only the values 20, 25, 30, 41 and 54 db given in
Table 18.

Page 50 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar
Lap Splices v Overlapped Bars and Cogs v 90O Bends

There are obviously many situations where there is no need to transfer


load, however bars need to be overlapped and tied together. In these
cases the overlap may only need to be 100-150 mm for a small bar and
up to 300 mm for a large bar. The overlap should be specified in the
drawings, otherwise a full splice may be provided, or even worse, a short
overlap provided where a full lap is essential. These overlaps can be
tabulated in many cases to avoid repetitive notes.

At the end of some bars, a 90º bend can be mistaken for a 90º hook.
Without knowing the purpose of the bend, a clear distinction often cannot
be made. As a general rule, most 90º bends are scheduled as cogs (90º
hooks) where the length of steel required to bend it is shown in Table 20.
These lengths are the smallest that can be bent around the stated pin size.

Where the bar dimension appears to fit into the concrete, allowing for
covers, a 90º bend would be assumed. Where it won’t fit, then the detail
should be revised to avoid the bar-end from sticking out of the concrete.
See Tables 21 and 22.

The Smorgon ARC Reinforcement Handbook Page 51


Reinforcing Bar

11.5 Bar Hooks and Cogs


Hooks are defined in AS3600 Clauses 8.2.12.4, 13.1.2.5 and 19.2.3.2.
The length of steel needed to physically make each hook is given in Tables
20, 21 and 22. The length of steel in a bar with a hook is the overall length
of the straight portion plus hook or cog length.

AS3600-2001 requires a longer hook to provide end anchorage of a beam


ligature than the standard hook defined in Clause 13.1.2.5. This is due to
the change in Clause 8.2.12.4.

AS3600-1994 Clause 8.2.12.4 End anchorage of bars

Bars used as shear reinforcement shall be anchored to develop the yield strength of the bar at mid-
depth of the member.

A fitment hook shall be deemed to develop 0.5fsy.


f in accordance with Clause 13.1.2.5.
A fitment hook which encloses a longitudinal bar shall be deemed to develop 0.67fsy.
f
Notwithstanding the above, fitment cogs shall not be used when the anchorage of the fitment is solely
in the concrete cover of the beam. Fitment hooks shall be used in this case.

AS3600-2001 Clause 8.2.12.4 End anchorage of bars

Bars used as shear reinforcement shall be anchored to develop the yield strength of the bar, at any
point in the legs, transverse to the longitudinal flexural reinforcement.

This requirement for the anchorage of stirrups and ties shall be deemed to be met provided the
following requirements are met:

a) Bends in bars used as fitments shall enclose a longitudinal bar with a diameter larger than the
diameter of the fitment bar. The enclosed bar shall be in contact with the fitment bend.

b) A fitment hook should be located preferably in the compression zone of the structural member,
where anchorage conditions are most favourable. Such an anchorage is considered satisfactory,
if the hook consists of a 135º or 180º bend with a nominal internal diameter of 4db plus a straight
extension of 10db or 100 mm, whichever is the greater.

c) Where a fitment hook is located in the tension zone, the anchorage described in Item (b) is deemed
to be satisfactory provided the stirrup spacing calculated using Clause 8.2.10 is multiplied by 0.8
and the maximum spacing specified in Clause 8.2.12.2 is also multiplied by 0.8.

d) Notwithstanding the above, fitment cogs shall not be used when the anchorage of the fitment is
solely in the cover concrete of the beam.

Alternatively, anchorage may be achieved by a suitable weld.

The straight extension of a fitment hook has been increased six bar
diameters, from 4db to 10db. Fitment hooks in AS3600-2001 are not
standard hooks, as they were for previous codes. These changes are due
to the change in the requirement for development of the yield strength in
the bar at mid height of the beam to development of yield strength in the
bar at all points along the height of the beam stirrup. This is a departure
from the traditional design theory that derived from Truss Analogy. The full
height development and extra hook length for beam fitments is a
requirement for earthquake detailing.

Page 52 The Smorgon ARC Reinforcement Handbook


Reinforcing Bar

Figure 45: Steel length to form a hook or cog

Added length for a hook or a cog


Diameter of pin R6 R10 N12 N16 N20 N24 N28 N32 N36
4db Grade 250N beam fitments 145 170 205 275 Not to be used
4db Grade D500N beam fitments - - 205 275 340 410 480 550 615
5db All main bars 120 155 170 200 245 295 340 390 440
6db 130 165 185 220 270 320 375 430 480
8db 140 185 210 260 315 380 440 505 570
Table 20: Length of steel required to bend a hook and cog
Notes:

1. See section 10.8 for background information from AS3600, including


rebent and coated bars.

2. A pin size equal to or less than the quality-control bend test must never
be used.

Figure 46: Overall dimension of a hook or cog

Overall Dimension, mm
Diameter of pin R6 R10 N12 N16 N20 N24 N28 N32 N36
4db Grade 250N beam fitments 40 60 70 100 Not to be used
4db Grade D500N fitments - 60 70 100 120 140 170 190 220
5db main bars, AS 3600 - 70 80 110 140 170 200 220 250
6db - 80 100 130 160 190 220 260 290
8db - 100 120 160 200 240 280 320 360
Table 21: Approximate overall dimension of a 180º hook

Overall Dimension, mm
Diameter of pin R6 R10 N12 N16 N20 N24 N28 N32 N36
4db Grade 250 beam fitments Not to be used
4db Grade D500N beam fitments Not to be used
5db main bars, AS 3600 - 160 180 215 260 310 365 415 470
6db - 180 200 240 290 345 400 460 515
8db - 200 230 280 340 405 470 540 605
Table 22: Approximate overall dimension of a 90º cog
In the above tables, no allowance has been made for spring-back after
bending. All dimensions are therefore nominal. The real overall diameter of a
deformed bar is approximately 112% of the nominal diameter. A 90º bend
longer than 10db overall gives the same anchorage as a 90º cog.

The Smorgon ARC Reinforcement Handbook Page 53


12.0 Reinforcing Mesh
12.1 Mesh General Information

Cold Rolled, High Strength Fabric of Grade R500N

Smorgon ARC produces a 500 MPa Ductility Grade N mesh to suit your
project requirements. The DuctileMesh 500™ fabric sheets are a welded
square or rectangular grid of R500N bars.

Contact your local Smorgon ARC branch to discuss your project


requirements for Ductility Grade N mesh.

Cold Rolled, High Strength Deformed Fabric of Grade D500L

Smorgon ARC fabric is available in 2.4 x 6.0 metre sheets and in 2.4
metre wide rolls. It is also available in purpose made sheets to suit your
project requirements. The mesh sheets are a welded square or rectangular
grid of D500L bars.

Welded fabric permits maximum construction speed and economies. The


cost and time required to lay mesh sheets is much less than that required
to place, space and tie together loose bars. Typically fabric also provides
greater crack control than loose bars as the bars that make up the sheet
are of smaller diameter and at closer spacings.

Smorgon ARC fabric is commonly available in


sheet sizes ranging from RF42 to RF1218 and in
trench mesh strips from RF8TM3 to RF12TM5.

Figure 47: Welded mesh intersection

Figure 48: Mesh production by automatic welding machines

Page 54 The Smorgon ARC Reinforcement Handbook


Reinforcing Mesh

12.2 Cross-Sectional Area of Smorgon ARC Mesh

Table 23: Design area of Smorgon ARC mesh


Notes:

1. Trench mesh is normally specified by the number of wires used in either the top and/or bottom of the footing so
that the design cross-sectional areas given above are not often referred to. Common trench mesh strip widths are
200 mm (3 wires), 300 mm (4 wires), and 400 mm (5 wires). See AS2870.1

2. The steel grade for standard fabric and trench mesh is D500L.

3. Fabric configurations are not limited to the standard fabrics shown above. Fabric main wire spacings are the most
critical factor for special meshes, and detailers should check with Smorgon ARC before finalising a design using
any fabric not included in the list of standard fabrics.

4. Fabrics RF 63 and RF 53 have an internal mesh size of 300 mm x 300 mm. The sheet size is 6 m long by
2.3 m wide. The 100 mm closer wire spacings on the side reduce the minimum side lap to 100 mm, rather
than 300 mm. They are not available in every state.

5. Although the fabrics listed above are generally available ex-stock, we recommend that designers and users check
with their local Smorgon ARC office if they have any questions about properties or availability.

6. The RF (Ribbed Fabric) prefix is used to denote a D500L mesh to AS4671-2001. The RF prefix is well established
in the engineering community and avoids the confusion of the RL and SL designations.

The Smorgon ARC Reinforcement Handbook Page 55


Reinforcing Mesh

12.3 Physical Dimensions of Smorgon ARC Mesh

Table 24: Smorgon ARC mesh details

Notes:

1. The mass of fabric per square metre is based on a piece cut from the interior of a full sheet which is one metre
square with equal overhangs on opposite sides.

2. Common trench mesh strip widths are 200 mm (3 wires), 300 mm (4 wires) and 400 mm (5 wires).
See AS2870.1, Residential Slabs and Footings Part 1- Construction, for applications.

3. Fabrics RF 63 and RF 53 have an internal mesh size of 300 mm x 300 mm. The sheet size is 6 m long by
2.3 m wide. The 100 mm closer wire spacings on the side reduce the minimum side lap to 100 mm, rather
than 300 mm. They are not available in every state.

4. Although the fabrics listed above are generally available ex-stock, we recommend that designers and users check
with their local Smorgon ARC office if they have any questions about properties or availability.

Page 56 The Smorgon ARC Reinforcement Handbook


Reinforcing Mesh

12.4 Wire and Fabric Development Length


Development Length Lsy.t For Plain Wire

AS3600 Clause 13.1.2.1 (c) allows a development length of 50 d for hard


drawn wire. The D500L grade bars are cold rolled wires.

Value of L.sy.t for wires of grade 500 MPa


Wire size 4.0 4.75 6.0 6.75 7.60 8.55 9.50 10.65 11.90
mm mm mm mm mm mm mm mm mm
50 d wire 200 240 300 340 380 430 475 535 595

Table 25: Development length and laps for deformed wire fabric (AS4671 and AS3600)

It is often not appreciated that the requirements of these Standards are


closely inter related.

AS4671, Clause 7.2.5 gives the minimum welded connection shear force
for mesh as 0.5 Rek.L As, that is, half the yield force of the largest bar at
the weld.

To develop the design stress of the wire (Rek.L As) at least two welded
intersections must be embedded (2 x 0.5 Rek.L As). To transfer this stress
from one sheet to another, a minimum overlap of two welded intersections
must be specified. These are the reasons for the requirements of Clause
13.2.3 of AS3600.

Thus embedment of two cross wires by 25 mm or more, from where full


strength is required can be assumed to develop the full design strength of
the mesh wire.

Each wire of welded wire fabric develops its stress by normal adhesive
bond with concrete together with bearing, against the concrete, of cross
wires welded transversly to it. Adhesive bond to the wire is usually
neglected for cross-wire spacings up to 200 mm. No advantage is given
to deformed wires. Most overseas Standards specify the minimum
overlaps of 200 mm or more because the weld-shear strength is limited to
0.3fsy.wire. Thus at least three, and often four, wires must be overlapped
leading to serious bunching.

Development Length for Mesh with an Overhang

In certain circumstances, such as at a support, the bond of the


overhanging wires can be utilised for stress development. Clause
13.1.2.1 ( c ) allows Lsy.t for wire to be 50 dwire. AS4671 requires a
weld strength of 0.5 Rek.L As.

The following table shows the development strength of one cross


wire plus an overhang of 25 dwire.

Figure 49: Mesh with an overhang

Wire size. 4.0 4.75 6.0 6.75 7.6 8.55 9.50 10.65 11.90
mm Mm mm mm mm mm mm mm mm
25 d wire + 25 125 145 175 195 215 240 265 295 325
Table 26: Embedment length of one weld plus an overhang of 25 dwire + one weld + 25 mm

Note: Values are provided as a basis for an engineering judgement.

The Smorgon ARC Reinforcement Handbook Page 57


Reinforcing Mesh

12.5 Mesh Detailing


Specify the Sheet Direction

The most important requirement for structural safety of a slab is that the
correct reinforcement is placed in the direction of the span which controls
the strength characteristics.

In slabs supported on beams or walls, the controlling span is the


Overlap at end of sheet with SHORTER span – this is true whether the slab is supported on three sides
overhang, all ARC fabric styles or on all four sides.

In slabs supported by columns, such as flat-slab floors and flat-plate


floors, it is the LONGER of the two spans which control the strength.
Because the reinforcement for these is complicated, well prepared detail
drawings must be provided.

However for minor structures, the reinforcement details are often not well
documented and steel fixers must be given additional instructions on the
sheet direction.

Overlap at side of sheet, rectangular All drawings should indicated the direction in which to place the
meshes, RF1218 to RF718, and longitudinal wires of fabric, and also illustrate how fabric sheets are to be
square mesh RF81 lapped.

Rectangular fabrics such a F718 and F818 require particular care when
detailing them.

Where suspended slabs have a span less than 6 metres, it is unusual that
fabric would need to be lapped at the end of a sheet.

If end laps are required, the actual length of the overhang should be
allowed for and specified, and a clear statement made on the drawings
Overlap at side of sheet, square whether or not the overhang is included in the lap unless the following
meshes edge side-lapping wires rules are observed:
RF102 to RF52, RF63 and RF53
1. Full width sheets are overlapped by the distance between the two
outermost edge wires.

2. When cut sheets are lapped, the outermost two wires are also
overlapped, and the length of the overhang is neglected.

Additional lap-splice strip. The Example of laps are given in Figure 50.
cross-wires are being spliced in this
example, so the cross-sectional area Specify the Fabric Position
(bar or wire sizes and spacing) must The next factor to be considered is to locate the fabric in the right position.
match. Fabric in the bottom of a slab must be supported on bar chairs from the
formwork.

Continuous bar chairs, such as the ARC “Goanna” chair, are the most
suitable here because they can be set out on the forms before the fabric is
placed and the weight of the fabric is evenly spread over many legs.
Thus, there is no need to place chairs under the steel that fixers are
standing on.
This example shows an Top reinforcement must be supported on high bar chairs, on high
INCORRECT method of lapping. “Goannas” or on “Deckchairs”.
Only one mesh is overlapped here
instead of two as required. Mesh Laps
The outermost wires of the lower
These laps are based on AS3600 and on AS2870.1. The wires should be
sheet are spaced at 100 mm. The
tied together to prevent slippage. For tying, the orientation of the sheets is
upper sheet has wires spaced at
not critical. That is, the lapped wires may be in the same layer or
200 mm. separated by the wires at right angles.

Additional strips or finger mesh must be used when it is critical that the
Figure 50: Mesh laps effective depth be maintained.
Page 58 The Smorgon ARC Reinforcement Handbook
Reinforcing Mesh

12.6 Special Fabric Design Information

Wire size 4.00 4.75 6.00 6.75 7.60 8.55 9.50 10.65 11.90
Spacing mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m

50 252 354 566 716 908 1148 1418


75 168 236 377 477 605 765 945 1188 1483
100 126 177 283 358 454 574 709 891 1112
125 101 142 226 286 363 459 567 713 890
150 84 118 189 239 303 383 473 594 741
175 72 101 162 205 259 328 405 509 635
200 63 89 142 179 227 287 355 446 556
250 50 71 113 143 182 230 284 356 445
300 42 59 94 119 151 191 236 297 371
350 36 51 81 102 130 164 203 255 318
400 32 44 71 90 114 144 177 223 278
450 28 39 63 80 101 128 158 198 247
500 25 35 57 72 91 115 142 178 222
1000 13 18 28 36 45 57 71 89 111
Table 27: Design cross-sectional area for reinforcing wire

Table 28: Nominal dimensions of reinforcing wire

Nominal diameter of wire mm 4.00 4.75 6.00 6.75 7.60 8.55 9.50 10.65 11.90
Nominal area of one wire mm2/m 13 18 28 36 45 57 71 89 111
Area provided by the number of wires as shown on left
Number of wires mm2 mm2 mm2 mm2 mm2 mm2 mm2 mm2 mm2
2 wires 25 35 57 72 91 115 142 178 222
3 wires 38 53 85 107 136 172 213 267 334
4 wires 50 71 113 143 182 230 284 356 445
5 wires 63 89 142 179 227 287 355 556 556
6 wires 76 106 170 215 272 344 425 535 667
7 wires 88 124 198 251 318 402 496 324 778
8 wires 101 142 226 286 363 459 567 713 890
Table 29: Cross-sectional areas of engineer designed fabric
Notes:

1. The longitudinal wire spacing should be restricted to between 100 mm and 200 mm, although a 300 mm spacing
is acceptable provided the quantity of fabric can be manufactured economically for the project.

2. The longitudinal wire spacings given in Table 27 should be regarded as a practical manufacturing limitation to
conserve costs. The size of the cross wire should be not less than approximately one-half the diameter of the
longitudinal wire, and spaced at 200 mm or 300 mm centres. Cross wire size and spacing is determined by the
design requirements.

3. Strip fabrics resemble trench mesh in that the sheets


are narrow (usual restricted to eight wires as a maximum)
but of a length calculated to fit the job dimensions. The
controlling factor of the size of the sheet is its mass. Where
possible each sheet should be capable of being carried and
placed by one or two men.

4. In all cases, please consult with your local Smorgon ARC


engineer before commencing a project using these fabrics.
A simple variation of a standard fabric may prove the most
economical.
Figure 51: Project mesh simplifies mesh laps

The Smorgon ARC Reinforcement Handbook Page 59


Appendix A-Area Comparison Table Grade D500L Mesh and D500N Bar

Area Comparison Table


D500L Mesh and D500N Bar

D500L Mesh D500N 12 D500N 16

RF 1218 (1112) N12-100 (1100) N16-200 (1000)

RF 1118 (891) N12-125 (880) N16-225 (889)

N12-150 (733) N16-250 (800)


RF 1018 (709)

N12-175 (629) N16-300 (667)


RF 918 (574)
N12-200 (550) N16-350 (571)
N12-225 (489) N16-400 (500)
RF 818 / RF82 (454)
N12-250 (440)
N16-500 (400)
RF 718 (358) N12-300 (367)
RF 102 (354)
RF 92 (287) N12-400 (275)
RF 82 (227)
N12-500 (220)
N16-1000 (200)
RF 72 (179)

RF 62 (141)

RF 41 (126)
N12-1000 (110)
RF 63 (94)

AS3600-2001 has restrictions on the use of D500L Reinforcing

Page 60 The Smorgon ARC Reinforcement Handbook


Appendix B-Smorgon ARC Bar Bending Shapes-Main Bars

The Smorgon ARC Reinforcement Handbook Page 61


Appendix B-Smorgon ARC Bar Bending Shapes-Fitments

Page 62 The Smorgon ARC Reinforcement Handbook


Appendix B-Smorgon ARC Bar Bending Shapes-General Shapes

The Smorgon ARC Reinforcement Handbook Page 63


Appendix B-Smorgon ARC Bar Bending Shapes-General Shapes

Page 64 The Smorgon ARC Reinforcement Handbook


Appendix C-Refurbishment of Buildings
The following tables summarise the design cross-sectional areas of fabric in imperial sizes manufactured by, or
available from, the company since the early 1920s up to the introduction of metric measurement in 1973.

The sources of the information are books published by the British Reinforced Engineering CO. Limited of Stafford,
England (BRC) up to 1950, and ARC Engineering CO. Pty. Ltd. (ARC) thereafter to 1973. Fabrics manufactured by
other Australian companies cannot be identified with certainty and are therefore not included.

Whilst the information given here is believed to be accurate, it is one thing to identify the notation given on a drawing
but it is an entirely different matter to be sure that the specified material was actually used.

The design drawings are the only guide to the quality of steel and concrete intended to be used. It is always possible
to test steel for yield stress, tensile strength, elongation, cross-sectional area (allowing for corrosion), etc. by removing
a sample from the structure. If the original diameter is difficult to determine because of corrosion, it may be better not
to proceed further.

Table 30 summarises the design yield stress of reinforcing steels. This should be adequate for most purposes using
present day analyses by limit state methods. Any attempt to compare the original working stress designs with AS3600
would require more information, probably not available, for little benefit in accuracy. In any case, to determine the
current structural adequacy requires application of current loading conditions.

The effective strength of steel does not decrease with time, however the contribution of the surrounding concrete can
be quite different from the original design specifications.

Table 30: Design yield stress of reinforcing steel

Notes:
1. Prior to 1960, the specified minimum yield stress of fabric was given as 70 000 pounds per square inch.
For refurbishment purposes, the tabulated value of 450 MPa is recommended.
2. Twisted bars can be identified by surface appearance. Remove untwisted ends (about 150 – 200 mm) before
splicing by end-butt welding or mechanical methods.
3. Intermediate Grade was rare and probably used only for projects designed in USA or designed to ASTM
standards for construction in Australia. Weldability is very doubtful and should not be considered.
4. Hard Grade was common in NSW, but unusual elsewhere. It is not weldable.
5. From 1988, AS3600 specified only a design yield stress of 400 MPa for deformed bars. This strength was not
manufactured until 1991 when AS1302 was amended.

The Smorgon ARC Reinforcement Handbook Page 65


Appendix C
As can be seen from Table 31, the cross wires for early rectangular mesh fabrics were very thin and the spacing was
much greater than AS4671 types. Their purpose was simply to hold the sheets together. Unless transverse cracking
is excessive, this will probably be of little consequence, but the fact should be noted.

Of greater concern may be the quality of the concrete. Again, if there is little evidence of excessive deflection, spalling
or rust, then the integrity of the structure is probably not in doubt for the loads it has carried in the past.

It is not well known that, until publication of AS3600, the fire resistance requirements of prior Standards was
determined from information available before 1949. This was before the introduction of cold worked bars in Australia
yet the rules were assumed to be satisfactory without amendment. It is suggested that the provisions of AS3600-
2001 be considered rather than using standards in vogue at the time of construction.
Wire spacing inches 2 in. 3 in. 4 in. 6 in. 8 in. 12 in.
Wire spacing, millimetres 50.8 76.2 101.6 152.4 203.2 304.8
Size Wire diameter Cross sectional area Steel crossing areas for wire spacing:-
ISWG (inches) (mm) Sq in. Sq mm mm2/m mm2/m mm2/m Mm2/m mm2/m mm2/m
7/0 0.500 12.70 0.1963 126.7 2494 1662 1247 831 623 416
6/0 0.464 11.79 0.1691 109.1 2147 1432 1074 716 537 358
5/0 0.432 10.97 0.1466 94.6 1861 1241 931 620 465 310
4/0 0.400 10.16 0.1257 81.1 1596 1064 798 532 399 266
3/0 0.372 9.45 0.1087 70.1 1380 920 690 460 345 230
2/0 0.348 8.84 0.0951 61.4 1208 805 604 403 302 201
1/0 0.324 8.23 0.0824 53.2 1047 698 524 349 262 175
1 0.300 7.62 0.0707 45.6 898 598 449 299 224 150
2 0.276 7.01 0.0598 38.6 760 507 380 253 190 127
3 0.252 6.40 0.0499 32.2 633 422 317 211 158 106
4 0.232 5.89 0.0423 27.3 537 358 268 179 134 89
5 0.212 5.38 0.0353 22.8 448 299 224 149 112 75
6 0.192 4.88 0.0290 18.7 368 245 184 123 92 61
7 0.176 4.47 0.0243 15.7 309 206 154 103 77 51
8 0.160 4.06 0.0201 13.0 255 170 128 85 64 43
9 0.144 3.66 0.0163 10.5 207 138 103 69 52 34
10 0.128 3.25 0.0129 8.3 163 109 82 54 41 27
12 0.104 2.64 0.0085 5.5 108 72 54 36 27 18
14 0.080 2.03 0.0050 32. 64 43 32 21 16 11
Table 31: Imperial standard wire gauges expressed as metric cross-sectional areas

Identification of 400Y and D500N Bar


410 MPa and 400 MPa deformed bar from 1983 to 2000 was identified by two longitudinal ribs and transverse
deformations. For D500N Bar, two longitudinal half ribs were added to one side and one half rib to the other to
provide a visual identification of the steel grade.

Figure 52: 400Y bar obverse and reverse Figure 53: D500N bar reverse Figure 54: D500N bar obverse

Page 66 The Smorgon ARC Reinforcement Handbook


Appendix C

Table 32: Rectangular – Mesh Fabrics. Only main wire details can be identified with any degree of certainty

Table 33: Square – Mesh Fabrics. Main wire and cross wire sizes, spacing and areas are the same

Table 34: Cross wire size and spacings only

The Smorgon ARC Reinforcement Handbook Page 67


Appendix D – Metric and Imperial Bars and Fabric

Deformed bar size and (area)


Area in sq mm

From 2001 1973 to 2000 Pre-1973

This area applies to a The area applies to a The area applies to a


hot rolled deformed bar of hot rolled deformed bar of pre-metric bar with a yield
grade D500N Grade 400Y, to a plain bar of strength of 60ksi (ARC CW.60
Grade 250R, and to a cold and cold twisted deformed
worked Grade 410C bar) or 33.6ksi (structural
bar, from 1973 to 1983 grade plain and deformed bar)
but not to Square Twist.
Sizes are
in 1/8" :- e.g. #11 = 1-3/8" Ø
D450N50 (1960) Y50 (1960)
N40 (1260) Y40 (1260)

N36 (1020) Y36 (1020)


#11 (961)

N32 (800) Y32 (800)


#10 (794)

#9 (639)
N28 (620) Y28 (620)

#8 (510)
N24 (450) Y24 (450)
#7 (387)

N20 (310) Y20 (310)


#6 (284)

N16 (200) Y16 (200) #5 (200)

#4 (129)
N12 (110) Y12 (110)

R10 (80)
#3 (71)
#2 (32)
R6 (30)

Wire Size and (area)


Area in sq mm

From 2001 1995 to 2001 1973 to 1995


AS4671 AS1303 AS1303

These bars are These bars are These bars are


cold rolled cold rolled cold rolled
deformed bars of deformed 500MPa bars round 450 MPa bars
Ductility
Grade D500L

12.5 (122.7)

11.90 (111.2) 11.90 (111.2)


11.2 (98.5)

10.65 (89.1) 10.65 (89.1)

10.0 (78.5)
9.50 (70.9) 9.50 (70.9)

9.0 (63.6)
8.55 (57.4) 8.55 (57.4)

8.0 (50.3)
7.60 (45.4) 7.60 (45.4)

7.1 (39.6)
6.75 (35.8) 6.75 (35.8)

6.3 (31.2)
6.0 (28.3) 6.0 (28.3)
5.0 (19.6)

4.75 (17.7) 4.75 (17.7)

4.0 (12.6) 4.0 (12.6) 4.0 (12.6)

3.15 (7.8)

Cross reference table for metric and imperial reinforcing bars

Page 68 The Smorgon ARC Reinforcement Handbook


Appendix D

Square meshes
Area in sq mm

From 2001 1995 to 2000 1973 to 1995 pre - 1973

AS4671 AS1304 AS1304


200x200 200X200 200X200 150X150

Deformed 500 MPa Deformed 500 MPa mesh Round 450 MPa mesh Round 450 MPa mesh
Ductility Grade
D500L mesh

F640 (532)
F81 (503)
RF81 (454) RF81 (454) F630 (460)

F102 (393) F620 (403)


RF102 (354) RF102 (354)
F600 (349)
F92 (318)

RF92 (287) RF92 (287) F601 (299)

F82 (251) F602 (253)


RF82 (227) RF82 (227)
F603 (211)
F72 (198)
RF72 (179) RF72 (179) F604 (179)
F62 (156)
RF62 (141) RF62 (141) F605 (149)

RF41 (126) RF41 (126) F606 (123)


ARC63 (104)
RF63 (94) RF63 (94)
F608 (85)
RF52 (89) RF52 (89)

RF42 (63) RF42 (63) ARC53 (63)


F610 (54)
RF53 (59) RF53 (59)

Rectangular meshes
Main wire area in sq mm

From 2001 1995 to 2000 1973 to 1995 pre - 1973

AS4671 AS1304 AS1304


100x200 100X200 100X200 150X300
Deformed 500 MPa Deformed Round 450 MPa Round 450 MPa
Ductility Grade D500L 500 MPa mesh 251 sq mm mesh Cross wire area is
mesh 227 sq mm mesh 227 sq mm cross wire area variable. Generally cross
cross wire area cross wire area wire area is below
227 sq mm area
F300 (1241)
F1218 (1227)
RF1218 (1112) RF1218 (1112)
F301 (1064)
F1118 (985)

RF1118 (891) RF1118 (891)


F302 (920)

F303 (805)
F1018 (785)
RF1018 (709) RF1018 (709)
F304 (698)
F918 (636)
RF918 (574) RF918 (574) F305 (599)

F818 (503) F306 (507)

RF818 (454) RF818 (454)

F307 (422)
F718 (396)
RF718 (358) RF718 (358)
F308 (349)

F309 (299)

F310 (253)

Cross reference table for metric and imperial reinforcing fabric

The Smorgon ARC Reinforcement Handbook Page 69


Appendix E-Reinforcement Bar Chairs and Spacers
Chairs and spacers are used to position steel reinforcement so that the durability, strength
and serviceability of the structure is in accordance with the design specification.

AS3600-2001 considers bar chairs and spacers as embedded items. They are covered
by Clause 14.2. AS3600-2001 does not give any design guidelines for the type, spacing
or arrangement of reinforcement supports.

1. Durability is the most common form of failure for bar chairs. This is particularly prevalent
on the exposed underside of balconies. Wire bar chairs can cause rust spotting of the
concrete surface if care is not taken during construction. The choice of bar chair also
impacts on the durability of the concrete structure as it affects the cover to the
reinforcement.

For strength requirements, the bar chairs and spacers must hold the reinforcement in
position until the concrete has achieved initial set. The loads that the chairs can incur
include people walking over the reinforcement, stacked materials, mounded wet concrete
2. and vibration during the concrete placement. The bar chairs must also hold these loads
when subjected to heat. The forms can get as hot as 80ºC in northern Australia.

As bar chairs and spacers are placed against the form, they are usually visible upon close
inspection of the concrete surface. Some bar chairs are more visible than others as they
have a larger base area. Plastic bar chairs come in several colours, depending on the
manufacturer and the available plastic. Typical colours are black or grey, however white,
purple, green and many other colours are made.

3. Types of Bar Chairs


1. Slab on Ground Plastic Bar Chairs - Dual size plastic reinforcing spacers with a flat base
to minimise penetration through the moisture barrier. These bar chairs are purpose built
for supporting reinforcement in slabs that are cast against the ground or for slabs cast on
plastic sheeting. They are available for 25, 40, 50, 65, 75, 85, 90 and 100 mm. 105, 110,
125, 130, 140 and 150 mm cover chairs are available on special order.

2.Trench Mesh Supports - Plastic bar chairs for supporting trench mesh in strip footings.
4.
These chairs provide 50 mm of cover. The trench mesh supports clip onto
the trench mesh before lowering into the trench.

3. Fast Wheels - Plastic spacers for precast concrete and column applications.
These spacers are ideal for column cages where the cage is assembled then lowered
into position. Fastwheels are available in 15, 20, 25, 30, 40, 50 and 75 mm covers.

4. Clipfast Plastic Bar Chairs - Plastic bar chairs that clip onto the reinforcement.
They are available for bar and mesh reinforcement. Plastic bases are available for slab
5. on ground applications. As these chairs clip onto the reinforcement, they can be used in
vertical and top cover applications. They suit 15, 20, 25, 30, 35, 40, 45, 50, 60, 65 and
75 mm covers.

5. Plastic Tipped Wire Bar Chairs - These bar chairs are for suspended slab and
beam reinforcement being cast on timber or metal forms. The chair is made of wire and
each leg is plastic tipped. These are the most common bar chair used for suspended
slabs. They suit a large range of covers and slab thicknesses. Plastic tipped wire bar
chairs are available in 20, 25, 30, 35, 40, 45, 50, 60, 65, 70, 75, 80, 85, 90, 100, 110,
6. 120, 125, 130, 140, 150, 160, 170, 180, 190, 200, 210, 220, 230, 240, 250, 260, 280,
300, 320, 340 and 360 mm covers from the underside of the bar to the bottom form.
Metal bases are available for the plastic tipped wire bar chairs when used for slab on
ground applications.

7.

Page 70 The Smorgon ARC Reinforcement Handbook


Appendix E-Reinforcement Bar Chairs and Spacers
6. Goanna Continuous Wire Bar Chairs - A continuous, 2 m long wire bar chair for use in
suspended slabs. Each leg has a plastic tip for corrosion protection. They are available for
20, 25, 30, 40, 50, 65 and 75 mm covers.

7. Plastic Continuous Bar Chairs - A continuous, 2 m long plastic bar chair for use in
suspended slabs. They are available in 20, 30, 40 and 50 mm covers.

8. Plastic Deck Spacers - Plastic deck spacers are for suspended slabs and beams cast
8a. on timber or metal forms. They are available for 20, 25, 30, 35, 40, 45, 50, 65, 75, 90,
100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 mm covers from the
underside of the bar to the bottom form. Spacers 50 mm and less are as shown in 8a.
Spacers 65 mm and taller are as shown in 8b.

9. Plastic Deck Chairs - Plastic deck chairs are ideal for suspended slabs. The design of
the chair accommodates both the bottom reinforcement and the top reinforcement from
the one chair. The base provides covers of 25, 30 and 40 mm cover to the bottom
reinforcement. The top clip is available to suit covers from 90 to 220 mm in 10 mm
8b.
increments from the underside of the bar to the bottom form.

10. Concrete Spacers - Concrete spacers are available for 25, 30, 35, 40, 45, 50, 55, 60,
65, 75 and 100 mm cover.

11. Heavy Duty Clip-On Chairs - These chairs are made of plastic and are suitable for most
formed applications. The chair can clip to N12 and N16 reinforcement. They are available
for 30, 35, 40, 45 and 50 mm cover when clipped to a N16 bar. The covers when clipped
to N12 bars are 34, 39, 44, 49 and 54 mm.

9. 12. Folded Mesh Spacers - Folded mesh in 2.4 metre lengths provides a fast and accurate
method for spacing layers of reinforcement. Folded mesh spacers are suitable for
separations between layers from 70 mm to 400 mm. Mesh is folded to order, hence the
height is made to suit the project.

13. Truss Spacers - Truss spacers are used in suspended slabs and are made in lengths
from 3 to 6 m. They are available in 80, 110, 150 and 190 mm heights.

10.

11.

12.

13.

The Smorgon ARC Reinforcement Handbook Page 71


Contact our team of professionals and give them the opportunity to show you how.

Qld: Geebung 131 557 SA: Dry Creek 131 557


NSW: St Marys 131 557 WA: Welshpool 131 557
Vic: Sunshine 131 557 NT: Darwin 131 557
Tas: Launceston 131 557 Website: www.smorgonarc.com.au

WAW SMG 332

You might also like