Handbook PDF
Handbook PDF
Handbook PDF
Your guide
to steel
reinforcement
Smorgon ARC is a Division of The Australian Steel Company (Operations) Pty
Ltd ABN 89 069 426 955
Smorgon ARC National Office
528 Ballarat Road
Sunshine 3020 Australia
Smorgon ARC reserves the right to alter the design or discontinue any of
its goods or services without notice. Whilst every effort has been made to
ensure the accuracy of the information and illustrations in this publication,
a policy of continual research and development necessitates changes and
refinements which may not be reflected in this publication. If in doubt
please contact the nearest Smorgon ARC sales office.
James O’Grady
Chief Engineer
Smorgon ARC
November 2001
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2.0 Australian Codes, Standards and References . . . . . . . . . . . . . . .2
3.0 Smorgon Steel Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4.0 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.1 General Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.2 Reinforcement Production Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.3 Reinforcement Material Property Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5.0 Smorgon ARC Reinforcement Product Range . . . . . . . . . . . . . . .12
6.0 Reinforcing Bar Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
6.1 Cutting Bars to Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
6.2 Bending Reinforcement to Shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
6.3 Welding Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
6.4 Mechanical Splices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
7.0 Rust and Protective Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . .22
8.0 Quality Assurance and Quality Control . . . . . . . . . . . . . . . . . . . .25
9.0 Tolerance on Bar Manufacture . . . . . . . . . . . . . . . . . . . . . . . . . .27
10.0 Information from AS3600-2001 . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.1 Clause 1.1.2 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.2 Clause 1.4 Information on Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.3 Cover to Reinforcing Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
10.4 Section 4 Cover for Durability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
10.5 Section 5 Cover for Fire Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
10.6 Clause 6.2 Properties of Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
10.7 Clause 7.6.8.3 Class L Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
10.8 Clause 19.2 Material and Construction Requirements for Reinforcing Steel . . . . .33
10.9 Clause 19.5.3 Tolerance on Position of Reinforcement . . . . . . . . . . . . . . . . . . . .35
11.0 Reinforcing Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
11.1 Bar General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
11.2 Bar Tension Lap Length and Anchorage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
11.3 Bar Compression Lap Length and Anchorage . . . . . . . . . . . . . . . . . . . . . . . . . .48
11.4 Additional Information On Lap Splices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
11.5 Bar Hooks and Cogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
12.0 Reinforcing Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
12.1 Mesh General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
12.2 Cross-Sectional Area of Smorgon ARC Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . .55
12.3 Physical Dimensions of Smorgon ARC Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . .56
12.4 Wire and Fabric Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
12.5 Mesh Detailing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
12.6 Special Fabric Design Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Appendix A Area Comparison Table Grade D500L Mesh and D500N Bar . . . . . . . . . . . . . . .60
Appendix B Smorgon ARC Bar Bending Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Appendix C Refurbishment of Buildings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Appendix D Metric and Imperial Bars and Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Appendix E Reinforcement Bar Chairs and Spacers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
To design and detail concrete structures correctly, the reader will need
access to several other books and reference manuals. Some suggestions
are given in the following pages.
• The Smorgon Steel mills turn the scrap steel into steel product. The
scrap is melted in a furnace. The molten steel is tested to determine the
properties of the steel. Additional trace elements are added to the
molten steel if required to meet the desired properties. The steel is then
cast into billets. The billets are rolled into straight and coiled reinforcing
bar as well as rod, merchant bar and structural sections.
Figure 3: Scrap being loaded into the charge bucket • Smorgon ARC processes the reinforcement to customer requirements.
The reinforcement is scheduled from engineers’ drawings, cut and bent
to suit, then delivered to the job site.
Scrap reinforcement, from Smorgon ARC and from the job site, is
collected by metal recycling companies and the cycle continues.
Reinforcement
Reinforcement is a general term used in AS3600-2001 (Concrete
Structures Standard) and by designers, reinforcement processors and
building contractors.
Reinforcement includes deformed bars, plain bars, wire, fabric and steel
products, all of which increase the tensile and compressive stress carrying
properties of concrete.
Reinforcement Bar
Figure 7: Coiled bar
A bar is a finished product rolled to close tolerances. Generally regarded
as being supplied in straight lengths, it is also manufactured in coiled form.
Reinforcing Mesh
Figure 8: Straight rolled bar
Mesh is manufactured in flat sheets with wires up to 12 mm diameter, or
rolls for fabric with wires up to 5 mm diameter. The sheets are typically 6
metres by 2.4 metres. The fabric consists of reinforcing bar welded in
either a square or rectangular grid.
Automatic welding machines ensure that the grid of wires has consistent
spacing to provide a defined cross-sectional area for designers. The wires
are welded electronically using fusion combined with pressure. This fuses
the intersecting wires into a homogeneous section without loss of strength
or cross sectional area.
Indented Wire
Here the outer shape is formed firstly by drawing hot rolled rod through a die
of circular cross-section, and then a pattern is indented into the surface. This
term is common in Europe, but not in Australia or USA.
Cold working is a process by which the final properties of a steel are provided
by rolling, twisting, drawing or tensioning a hot rolled steel, or by a
combination of two or more of these processes.
Between 1957 and 1983, the only high strength steels in common use were
cold worked.
Before twisting, the Grade 230 bars were either of square section (1957 to
1963) or deformed (1963 to 1983). After twisting, the yield stress (at 0.2%
proof stress) was 410MPa for design calculations and they were designated
as Grade 410C bars.
Cold worked bars are no longer produced by Smorgon ARC and are not
included in AS4671-2001.
Deformations
Deformations appear as a raised pattern on the surface of the bar. The overall
cross-section should be as circular as possible to facilitate uniform
straightening and bending. Deforming the surface is the final rolling operation.
The surface pattern consists of transverse deformations and longitudinal ribs.
Only the deformation contributes to the anchorage of a bar. The deformation
pattern allows considerable scope for steel makers to use additional ribs for
product and mill identification.
When considering the cross-sectional area or the mass per metre of a bar or
wire, the deformation is regarded as a redistribution of the material and not
Figure 15: The Smorgon mill mark is a vertical rib as an appendage.
Example 1
• If a force of 60 kilonewtons (kN) is applied to an N16 bar of
area 200 mm2, the stress in that bar is:
= 60,000/200
= 300 newtons per mm2, 300 megapascals or 300 MPa
• Conversely, for the same stress of 300 MPa, the N32 bar
would be carrying a load
= 300 x 800 newtons
= 240 kN
Figure 16: Stress-strain curve Strain is a measure of the amount by which a tensile force will stretch the
bar. Strain is expressed in the units of ‘mm/mm’, or ‘percentage strain’
based on the original gauge length.
Example 2
Using our N16 example from above, the relationship between stress and
strain is:
• Strain
= the stress divided by Young’s Modulus
= 300/200,000
= 0.0015 mm/mm
= 0.15% of the gauge length
Using the N16 example again with a gauge length of 5 bar diameters, we have:
Example 3
For the same N32 bar at a stress of 75 MPa:
• Strain
= 75/200,000
= 0.0004 mm/mm
Obviously, a lower stress in the bar means smaller strain and thus
narrower crack widths, if they occur.
With hot rolled bars, the ‘yield point’ is quite visible on the
stress–strain curve. Once the yield point is reached, the strain
increases rapidly for a minor increase in the applied load. The
stress level at yield is called the yield stress and the steel is said to
have ‘yielded’. After yield, the strength of the bar increases due to
strain hardening until the tensile strength is reached. After
maximum tensile strength has been reached, the capacity of the
bar reduces and necking is visible. Eventually the bar breaks.
Figure 17: Yield stress
In fact, if the bar is unloaded part way through the test, below the yield
point, the bar will return to its original length. This is why it is called elastic
behaviour. The yield stress measured with a second test will be at least as
high as it was during the first test.
To illustrate the connection between stress, strain and yield stress, there is
also a ‘yield strain’ calculated as follows:
There are three properties that relate to each other in the elastic range:
1. Young’s Modulus
= 200,000 MPa for all steels
AS4671-2000 allows the 0.2% proof stress to be used as the yield stress
when there is no observable yield point.
Plastic and drying shrinkage are two other causes of stress in concrete.
For Australian concretes, the shrinkage strain ranges from 0.0005 mm/mm
to 0.0012 mm/mm. This range is close to the yield strain of Grade 250
bars (0.00125 mm/mm). AS3600-2001 contains rules for control of cracks
caused by shrinkage and flexure for bars and fabric up to Grade 500 (yield
strain 0.0025 mm/mm).
Ductility
Ductility is the ability of a structure to undergo large deformations and
deflections when overloaded. If a structure cannot withstand large
deformations and deflections when overloaded, then it is subject to brittle
failure.
AS4671 has introduced three ductility grades for reinforcing steel and two
ductility measures. AS3600-2001 has also retained the ductility control of
a reduced strength reduction factor for bending members with a ku > 0.4,
that is for bending members with excessive tensile steel.
The three ductility grades are Low (L), Normal (N) and Earthquake/Seismic
(E). The measures for ductility are Uniform Elongation and the Tensile
Strength / Yield Stress Ratio.
L-100
Agt = ( + Tensile Strength ) x 100%
L 200,000
Figure 19: Uniform elongation
AS4671-2001 gives minimum values for the Uniform Elongation (Agt) for
the different reinforcing steels.
When normal mill steels such as plate, wire, and plain or deformed bars
are bent or otherwise reshaped, the steel becomes less ductile with time.
There are many reasons, but the main cause seems to be change in
crystal structure and the effects of the chemical composition.
Chemical Composition
The selection of the correct chemistry for any steel product is extremely
important because it can have a marked effect on the use of the final
product.
Carbon
Carbon turns iron into steel. The Carbon content of steel is limited
because as the carbon content increases, the ductility of the steel
decreases.
Other Elements
• Manganese increases the strength of steel up to a certain point
• Nitrogen, Phosphorous, Silicon and Sulphur can be deleterious
• Micro-alloying and grain-refining elements, such as
Aluminium, Niobium, Titanium and Vanadium, can be used
to increase the strength but they can affect other
properties, sometimes not to the best advantage of the
steel.
• Residual elements such as Copper, Nickel, Chromium and
Molybdenum can occur in steel if they are present in any
scrap used in steel making. Up to a certain limit they may
be considered as incidental and not detrimental to the
product.
When the CE exceeds 0.45, the steel cannot be welded (see Figure 21).
Material Grade Size Range Yield stress Usage Rolling Mill Type
Plain rod R250N 6.5, 10, 12.5 mm coil 250 MPa Fitments As- rolled, rod mill
Plain rod R250N 5.5 to 14 mm coil 250 MPa Feed for wire As- rolled, rod mill
Deformed bar D500L 4 to 11.9 mm coil 500 MPa Fabric, fitments Drawn or rolled from rod
Deformed mesh D500L RF43 to RF1218 fabric 500 MPa General use Drawn or rolled from rod
Round mesh R500N 6 to 12 mm fabric 500 MPa Suspended slabs Produced under patent
Plain bar R250N R10 to R36 straight 250 MPa Dowel bars Merchant mill
Deformed bar D250N S12 straight 250 MPa Swimming pools Merchant mill
Deformed bar D500N N12 & N16 coil 500 MPa General use Rod mill
Deformed bar D500N N12 to N36 straight 500 MPa General use Merchant mill
Deformed bar D500N N40 straight 500 MPa Special order Merchant mill
Deformed bar D450N D450N50 straight 450 MPa Special order Merchant mill
Table 3: Reinforcing steel product range
The Concrete Structures Standard, AS3600, and the Reinforcing Steel
Standard, AS4671, must be regarded as interrelated performance
standards. However, although a particular reinforcing steel may comply
with, or even exceed, some of the minimum requirements of its Standard,
that steel must not be used above the maximum stress limits set down in
AS3600.
Figure 22: D500N straight stress-strain curve Figure 23: D500N coil stress-strain curve
Figure 24: D500L stress-strain curve Figure 25: D250N stress-strain curve
Rod diameters are not the same as bar sizes: rod is available in 0.5 mm
increments in the range 4 mm to 14 mm. Only selected sizes are used for
reinforcement as fitments.
Figure 26: D500L deformations This is a low carbon, deformed 500 MPa steel. The steel is produced in
coils by cold rolling, which is straightened to produce bars. D500L bar
and coil are available in sizes from 4 mm to 11.9 mm.
Figure 28: D500N coil bar deformations Grade D500N Deformed Bar
Grade D500N bar is produced as low carbon, hot rolled deformed bar in
straight lengths and in coils. Straight lengths are available from 12 mm to
40 mm diameter. 12 mm and 16 mm diameter D500N bar typically are
supplied from coils.
OBVERSE
REVERSE
Figure 29: D500N straight bar deformations
Introduction
The Australian reinforcement industry involves a very short supply chain
from steel maker to consumer.
There are two steel producers, Smorgon Steel, based in Victoria and
Onesteel, based in New South Wales. Both companies roll bar and rod.
There are 47 Smorgon ARC branches in all states and territories ranging
from large plants, which manufacture mesh and process steel bar for
major projects, down to small centres situated in metropolitan and country
areas to service local needs quickly. These Smorgon ARC outlets sell to
the public as well as to building contractors. There is also a well
established reseller network which maintain stocks of fabric and other
materials.
Reinforcement Processing
The term “processing”, as used in the reinforcement industry, includes the
complete range of operations that translate information on an engineering
drawing into usable pieces of steel delivered to the building site. The
summary that follows applies to the processing of reinforcing bar:
• Bending to shape
After cutting, reinforcement may need to be bent to shape. The required
shape is determined by the shape of the concrete outline. The shape is
defined by a dimensioned sketch on the schedule and tag.
• Invoicing
• Guillotine shear
This is a large machine suitable only for factory cutting. Up to 20 smaller
diameter bars can be cut at once. Although rough, the ends are suitable
for welding, where specified, but not for end-bearing splices.
• Friction saw
A portable saw of this type can be used on site.
• Oxy-acetylene torch
For trimming or removing steel. The heat generated during cutting extends
only a short way along the bar and, as such, does not affect either the
strength or anchorage of a bar end. Take care to avoid spatter on to
adjacent steel during cutting. Bars cut using heat are not suitable for end-
butt welding.
Manufacturing Tolerances
To enable building materials to fit together, an allowance is required to
permit minor variations from the exact value specified. This allowance is
called a tolerance. Tolerances on reinforcement are given in AS4671,
Section 7, and AS3600, Section 19.
Example A
Required Cut from stock Scrap
i. 20 x 6000 20 x 6000 0m
ii. 20 x 6000 10 x 12000 0m
iii. 20 x 6100 20 x 7000 20 x 900 mm
iv. 20 x 6100 +
20 x 3800 20 x 10000 20 x 100 mm
• In cases (i) and (ii), different stock lengths allow alternative solutions.
• Intercutting between two orders, in case (iv), reduces scrap and utilises
one stock length for two scheduled lengths.
Example B
Required Cut from stock Job
• In case (ii), the two bundles go to the same site, but one bundle is used
for slab and the remainder for wall which may not be poured for another
week.
These examples illustrate how widely the material from one heat can be
spread and why traceability after processing has been replaced by a
quality assurance programme, with better results at a realistic cost.
Bar Shapes
There are several reasons for bending bars:
When straight steel is bent a very limited amount, it will spring back to
straight. This is because it is still in the elastic range.
When a bar is bent to shape during processing, the steel again has been
strained beyond its yield point; if it had not, it would have straightened out!
Thus all steel bending changes the material from its original state and any
investigation of its properties must allow for this.
The diameter of a bend should not be so large that the hook cannot fit
inside the concrete or that it will pull out rather than act as a hook. Nor
should it be so small that the pressure between the bend and the concrete
will crush the concrete. A compromise value of 5db for general bending
has worldwide acceptance. One of the quality control requirements for a
Figure 33: Automatic bending machine for coil reinforcing steel is that it will pass a bend test. For bars, this test is
reinforcement described in AS4671. Despite claims made about the degree of bending
which can be sustained by some steels in a laboratory, treatment on a
building site can be much more severe. For this reason AS3600 prohibits
the use of small diameter pins at or below the bend test sizes. Cold
weather bending and the occasional on-site ‘adjustment’ also require
larger pin sizes.
Coated bars are bent about larger pins than uncoated bars. The minimum
pin diameters specified for galvanised or epoxy-coated bars are based on
three requirements:
(ii) Secondly, with galvanised bars, a small bending diameter is more likely
Figure 34: Manual bending machine for straight
reinforcement to break the zinc surface coating.
(iii) Thirdly, the pickling process during hot dip galvanising can lead to
hydrogen embrittlement of the reinforcement. The greater the cold
working of the steel, the more susceptible it is to hydrogen
embrittlement. The larger pin diameter for galvanised bars and for bars
to be galvanised reduces the cold working of the reinforcement.
The straightener often leaves a series of marks on the bar surface, but this
does not affect the anchorage properties.
On-Site Rebending
Rebending or straightening bars is a common practice on-site.
Instructions on a suitable procedure should be given in the structural
drawings, even if it is known that such bending will not be needed. A
tolerance on straightness should also be provided; an axial deviation of
the centre line of one bar diameter along with a directional change of 5O
is considered acceptable.
Any on-site cold bending should only be done with a proper bar bending
tool. Pulling the bar against the edge of the concrete, hitting the bar with a
sledge hammer or using a length of pipe damages the surface of the
reinforcement, reduces its ductility, can cause breakage of the steel and
may cause premature failure of the concrete element.
In general, preheat is not required for welding reinforcing steel. The heat
input should be controlled to avoid changing the metallurgical properties of
the steel and hydrogen controlled electrodes should be used.
• Slip – Most international codes limit the slip in the coupler to 0.1 mm at
70% of the yield load. This is to restrict the width of cracking at the
coupler location. Typically cracks in concrete are limited to 0.3 mm
width. If the coupler slips 0.1 mm under load, then the crack at the
surface of the concrete will be greater than 0.1 mm. Shrinkage, creep
Figure 37: Bartec thread and flexural cracking will add to the crack width that has resulted from
slip within the coupler.
Reinforcement that has been fixed for some time before concrete
placement may, after rain, show lines of iron oxide (rust) on the forms. If
the forms are not cleaned and the staining removed prior to pouring the
concrete a rusty looking line will be visible on the concrete soffit. This is an
aesthetic problem, not a structural or durability problem.
Mill Scale
Mill scale on hot rolled products, in the levels found on Australian
produced reinforcement, is not detrimental to the reinforcement. Wire and
fabric are free of mill scale.
Types of Coating
The two principal protective coatings are hot dipped galvanising and
fusion-bonded epoxy coating. The former is generally available in most
major centres, although there may be a physical limit to the size of the zinc
bath in some localities. Fusion bonded epoxy coating in Australia is not
easily obtainable.
Limits for the molten metal and finished appearance are given, together
with test requirements for coating mass and adherence.
Epoxy Coating
An excellent reference is ‘The Epoxy Coated Rebar CD-Rom’, produced
by the Concrete Reinforcing Steel Institute, 9333 North Plum Tree Grove,
Schaumber, IL, 60173, USA.
Applicable Standards
AS/NZS ISO9001:2000 Quality Management Systems provides the basis
for steel industry QA systems. Explanations of the application of these
standards is beyond the scope of this handbook.
Firstly, the quality of the raw material (steel bar and wire) is controlled
during steel making and wire drawing. These materials are covered by test
certificates or certificates of compliance with the appropriate standards.
Each bundle or coil is tagged and identified by a serial number, from which
the heat number, date of production and other details can be obtained.
Delivery dockets show that the material is ‘deemed to comply’ with the
relevant standard, indicating that the steel maker has a certified Quality
Assurance programme in place.
Quench and self tempered bars and micro alloy bars are not segregated
because they are both Grade D500N to AS4671.
Figure 40: Testing the chemical and physical AS4671 has an Appendix A which sets out the various methods by which
properties of the steel in the molten state a manufacturer can show compliance with the Standard.
Whilst large structural steel sections and plate can be readily identified
back to their heat, bar and wire cannot. The latter have one big advantage
- if there is any doubt about quality, a sample length can be taken and
tested very easily.
Each heat of steel produces about 80 to 100 tonnes of steel, which is cast
into billets of approximately 1.5 tonnes. The chemical composition of the
heat is obtained by spectroscopic methods and is documented as a
whole.
Each billet is rolled to one size producing 1.5 tonnes so that if 4 tonne
bundles are ordered, more than one billet is required. More than one heat
may be involved, but this is unusual. After rolling, the finished bar is tensile
and bend tested, and the results documented.
Traceability of Material
On-site traceability is the responsibility of the contractor. When
performance assurance is given for the material, on-site traceability should
not be required.
(e) Deformations
There are no tolerances given for deformations. Values are maximum or
minimum. See Clause 7.4 and Appendix C3 of AS4671.
Although there are many clauses which refer to reinforcing steel, the
following references are those most applicable to its supply and fabrication.
NOTE: The use of Ductility Class L reinforcement is further limited by other clauses within this Standard.
The two primary purposes of cover are durability and fire resistance.
As a general rule, cover is selected from an appropriate table but there
are several cases where additional cross checks are required.
(a) the most severe Exposure Classification for durability (A1 to U);
(b) the characteristic compressive strength of the concrete ƒ’c for the most
severe situation for use in strength, serviceability and durability design,
allowing for abrasion and freeze/thaw conditions;
Combined Table from Clauses 4.3, 4.4, 4.5, 4.6, 4.10.3.2 and 4.10.3.3, for
the selection of minimum cover for corrosion resistance of reinforcing and
prestressing steel.
Concrete strength is not taken into account when selecting cover for fire
resistance. Similarly, the effects of fire need only be considered for
members which are required, by Building Regulations or through other
Authorities, to attain a specified fire resistance level. In certain structures
which have a high exposure classification, due to proximity with hazardous
materials for example, resistance to fire may take precedence over all
other factors.
NOTE: Reference should be made to AS/NZS 4671 for explanation to designations applying to 500 MPa steels.
10.8 Clause 19.2 Material and Construction Requirements for Reinforcing Steel
19.2.1 Materials
19.2.1.1 Reinforcement
Reinforcement shall be deformed bars Class N bars, or Class L or Class N welded wire mesh (plain or
deformed), with a yield stress of up to 500 MPa, except that fitments may be manufactured from Class L wire
or bar, or plain Class N bar.
All reinforcement shall comply with AS1302, AS1303, AS1304 or AS/NZS 4671 as appropriate.
(iii) On the overall offset dimension of a cranked column bar . . . . . . . . . . . . . . . . . . . .–0, +10 mm.
(iv) For the sawn or machined end of a straight bar intended for use as an end-bearing splice,
the angular deviation from square, measured in relation to the end 300 mm,
shall be within . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2º.
(b) Bending of reinforcement shall comply with Clause 19.2.3.
(c) Welding if required shall comply with AS 1554.3. Tack welding not complying with that Standard shall not
be used.
19.2.3 Bending
19.2.3.1 General
(a) Cold, by the application of a force around a pin of diameter complying with Clause 19.2.3.2, so as
to avoid impact loading of the bar and mechanical damage to the surface of the bar; or
(i) The steel must be heated uniformly through and beyond the portion of be bent;
(ii) The temperature of the steel must not be allowed to exceed 600º C,
(iv) If during heating the temperature of the bar exceeds 450º C, the design yield strength of the
steel after bending shall be taken as 250 MPa.
Reinforcement which has been bent and subsequently straightened or bent in the reverse direction shall not
be bent again within 20 bar diameters of the previous bend.
This distance is intended to keep cold working from the original bending
zone separated from additional bending.
Reinforcement partially embedded in concrete may be field bent (ie, in situ) provided that the bending
complies with items (a) or (b) above, and the bond of the embedded portion is not impaired thereby.
The greatest need encountered with this bending is to control the bend
curvature without notching the bar, and to prevent spalling of the concrete,
particularly in thin members. It is very rare for a site bent bar to be bent
correctly, with bars often being pulled out against the edge of the concrete
or bent with a pipe. These methods of bending severely notch the bar and
can cause bar breakage.
The nominal internal diameter of a reinforcement bend or hook shall be taken as the external diameter of the
pin around which the reinforcement is bent. The diameter of the pin shall be not less than the value determined
from the following as appropriate:
(b) For reinforcement, other than specified in Items (c) and (d) below, of any grade . . . . . . . . . . . . . . . 5db
(c) For reinforcement, in which the bend is intended to be subsequently straightened or rebent, of
(i) 16 mm diameter or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4db;
(ii) 20 mm diameter or 24 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5db; and
(iii) 28 mm diameter or greater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6db.
Any such straightening or rebending shall be clearly specified or shown in the drawings.
(d) For reinforcement that is epoxy-coated or galvanized, either before or after bending, of
(i) 16 mm diameter or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5db;
(ii) 20 mm diameter or greater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8db.
Rust and millscale, of themselves, do not adversely affect bond. Dirt and
oil are much worse.
The position of reinforcement and tendons may differ from that specified
as follows where a ‘+’ value indicates that the cover may be greater than
specified and a ‘-’ indicates the cover may be less.
(a) Where the position (mm) is controlled by the minimum design cover, eg,
all round ties and stirrups, the cover at ends and from surfaces in walls
and slabs.
(b) Where the position is not controlled by the minimum design cover, for
example on-
Both quench and self tempered and micro-alloy reinforcing bars are
classified as Grade D500N and no distinction is made between them for
supply purposes. Each steel-maker identifies their rolling mill with its
individual surface mark.
1. The calculated area of a deformed bar is calculated from the bar size, in
mm, as if it was a circle.
Figure 43: Smorgon QST mill mark 4. The nominal mass includes the rolling margin, based on the calculated
mass plus 2.5%, and is used for calculating the mass of material sold in
all commercial transactions.
Bar Size Nominal Area Calculated Area Calculated Mass Nominal Mass
mm mm2 mm2 kg/m kg/m
Notes:
2. All values given in the above table are for 6.5 mm and 10 mm coiled rods.
3. Plain round bars for dowel bars are available in larger sizes to AS3679,
Grade 250. These sizes are: R12, R16, R20, R24, R27, R33 and R36,
but the full range may not be available from stock at all times.
Bar Size N12 N16 N20 N24 N28 N32 N36 N40 N50
No. mm2 mm2 mm2 mm2 mm2 mm2 mm2 Mm2 mm2
Notes:
1. This table would generally be used for the design of beams, columns and narrow footings, etc.
2. Before selecting the number of bars in one layer of a beam or column, check that they can fit across the member
width. The table below allows a quick assessment of spacing per bar.
3. Sizes N12 and N16 are available in as-rolled straight lengths, or as straightened lengths from coil. They may be
either quench and self tempered steel or micro alloy steel.
4. Sizes N40 and D450N50 are micro alloy bars and are available to special order only.
Bar Size N12 N16 N20 N24 N28 N32 N36 N40 N50
To estimate the minimum width, allow the space for each bar.
Table 11: Design cross-sectional area of deformed bars per metre width
Notes:
1. This table would generally be used for the design of slabs, walls and wide footings, etc.
2. Values for a centre-to-centre spacing of less than 4db is not provided because concrete is difficult to place and
splitting can occur along this plane. Note also that to apply AS3600 Clause 13.1.2.2, development lengths to
develop yield stress, the clear distance between bars must be not less than twice the cover to the bar being
designed.
3. Sizes N12 and N16 are available in as-rolled straight lengths, or as straightened lengths from coil. They may be
either quench and self tempered steel or micro alloy steel.
4. Sizes N40 and D450N50 are micro alloy bars and are available to special order only.
Lengths are based only on full yield stress of the steel. It is most unwise to
specify lap or anchorage lengths for a lower steel stress. For laps, this
practice is not permitted in AS3600-2001.
The anchorage and lap length formula in AS3600, Clause 13.1.2, for a
straight piece of deformed bar in tension is –
Depth factor k1 x spacing factor k2 x bar yield stress fsy x bar area A b
L sy.t =
[(smaller of twice actual cover or clear spacing 2a) + bar size db] x √ (concrete strength fc)
• When the yield stress of the bar increases, the anchorage length
increases;
• When the clear spacing between adjacent parallel bars increases, the
anchorage length decreases;
• When the actual cover to the bar increases, the anchorage length
decreases;
To assist with anchorage you can use a standard hook to provide end
anchorage of a bar where there is insufficient embedment for a straight
length to develop its design stress. A hook or cog reduces the
development length by 50%.
A fully stressed hook or cog will create a lateral splitting force on the
surrounding concrete, caused by the bearing stress between steel and
concrete at the bend. Hooked bars should never be used in thin sections,
say less than 12 bar diameters in the plane of the hook, or as top bars
in slabs.
A 90º bend which is longer than 10db overall, gives the same anchorage
as a 90O cog.
If the factors given in Clause 13.1.4 for bundled bars are applied directly to
the compression development length given in Clause 13.1.3, they become
24db and 26.6db respectively. Bundled bars in compression are not
commonly used other than in the columns of very high buildings so that,
for practical use, all development lengths have been rounded up to 30 db.
For practical use also, the lap splice for a single bar in compression is
rounded up from 41 db (Clause 13.2.4) to 54 db for a bundled bar (Clause
13.2.5).
Lap splices are always based on full yield strength ƒsy. To permit other
values would create uncertainty in the mind of fixers and inspectors, and
would certainly require more work from detailers. AS3600-2001 Clause
13.2.4 does not allow reductions in compression lap lengths.
Table 18: Development and lengths for Compression Development Length for Single Bars, L sy.c
deformed bars
(Clause 13.1.3)
The formula for L sy.c given in Clause 13.1.3 is not dependent upon
concrete strengths, steel strengths, or on the width or depth of the
member. It is equal to 20 db.
Although it is not stated in Clause 13.1.3, the minimum cover and spacing
rules still apply. Compression causes splitting of the cover in a different
way to tensile forces. A realistic spacing is required to ensure concrete can
be consolidated properly. Encircling ties may also be advisable in zones of
heavy reinforcement.
Compression bars must not be hooked.
Compression Lap Splices for Single Bars (Clause 13.2.4)
For 500 MPa bars in a compression zone of the concrete, the lap length is
41 db. This is twice the compressive stress development length. This value
also applies to lap splice lengths for column bars.
Compression bars must not be hooked. This is not restricted to columns
and walls. It applies to all members.
Page 48 The Smorgon ARC Reinforcement Handbook
Reinforcing Bar
Three or four bars can be tied tightly together to form a bundle. Each bar
of the “unit” therefore presents a smaller surface in contact with the
surrounding concrete. This requires an increased development length for
bundled bars (Clauses 13.1.3, 13.1.4).
In beams, the bar cut-off point of each bar in a bundle must be staggered
by 40 db (Clause 8.1.8.8).
The values in the table also apply to an extra splice bar added to a bundle
which did not have a sawn-end preparation for an end-bearing splice. The
splice bar must be at least twice the lap length given above, and located
centrally about the section where the splice is.
• For slabs and walls, the clear distance between adjacent parallel bars
being designed, over the length in which they are considered to be
developing stress or over the lap length, must not be less than 150 mm.
This does not restrict the spacing to 150 mm over the remainder of
the length.
For bars with more than 300 mm of concrete cast below them, the above
values must be increased by 25%.
At the end of some bars, a 90º bend can be mistaken for a 90º hook.
Without knowing the purpose of the bend, a clear distinction often cannot
be made. As a general rule, most 90º bends are scheduled as cogs (90º
hooks) where the length of steel required to bend it is shown in Table 20.
These lengths are the smallest that can be bent around the stated pin size.
Where the bar dimension appears to fit into the concrete, allowing for
covers, a 90º bend would be assumed. Where it won’t fit, then the detail
should be revised to avoid the bar-end from sticking out of the concrete.
See Tables 21 and 22.
Bars used as shear reinforcement shall be anchored to develop the yield strength of the bar at mid-
depth of the member.
Bars used as shear reinforcement shall be anchored to develop the yield strength of the bar, at any
point in the legs, transverse to the longitudinal flexural reinforcement.
This requirement for the anchorage of stirrups and ties shall be deemed to be met provided the
following requirements are met:
a) Bends in bars used as fitments shall enclose a longitudinal bar with a diameter larger than the
diameter of the fitment bar. The enclosed bar shall be in contact with the fitment bend.
b) A fitment hook should be located preferably in the compression zone of the structural member,
where anchorage conditions are most favourable. Such an anchorage is considered satisfactory,
if the hook consists of a 135º or 180º bend with a nominal internal diameter of 4db plus a straight
extension of 10db or 100 mm, whichever is the greater.
c) Where a fitment hook is located in the tension zone, the anchorage described in Item (b) is deemed
to be satisfactory provided the stirrup spacing calculated using Clause 8.2.10 is multiplied by 0.8
and the maximum spacing specified in Clause 8.2.12.2 is also multiplied by 0.8.
d) Notwithstanding the above, fitment cogs shall not be used when the anchorage of the fitment is
solely in the cover concrete of the beam.
The straight extension of a fitment hook has been increased six bar
diameters, from 4db to 10db. Fitment hooks in AS3600-2001 are not
standard hooks, as they were for previous codes. These changes are due
to the change in the requirement for development of the yield strength in
the bar at mid height of the beam to development of yield strength in the
bar at all points along the height of the beam stirrup. This is a departure
from the traditional design theory that derived from Truss Analogy. The full
height development and extra hook length for beam fitments is a
requirement for earthquake detailing.
2. A pin size equal to or less than the quality-control bend test must never
be used.
Overall Dimension, mm
Diameter of pin R6 R10 N12 N16 N20 N24 N28 N32 N36
4db Grade 250N beam fitments 40 60 70 100 Not to be used
4db Grade D500N fitments - 60 70 100 120 140 170 190 220
5db main bars, AS 3600 - 70 80 110 140 170 200 220 250
6db - 80 100 130 160 190 220 260 290
8db - 100 120 160 200 240 280 320 360
Table 21: Approximate overall dimension of a 180º hook
Overall Dimension, mm
Diameter of pin R6 R10 N12 N16 N20 N24 N28 N32 N36
4db Grade 250 beam fitments Not to be used
4db Grade D500N beam fitments Not to be used
5db main bars, AS 3600 - 160 180 215 260 310 365 415 470
6db - 180 200 240 290 345 400 460 515
8db - 200 230 280 340 405 470 540 605
Table 22: Approximate overall dimension of a 90º cog
In the above tables, no allowance has been made for spring-back after
bending. All dimensions are therefore nominal. The real overall diameter of a
deformed bar is approximately 112% of the nominal diameter. A 90º bend
longer than 10db overall gives the same anchorage as a 90º cog.
Smorgon ARC produces a 500 MPa Ductility Grade N mesh to suit your
project requirements. The DuctileMesh 500™ fabric sheets are a welded
square or rectangular grid of R500N bars.
Smorgon ARC fabric is available in 2.4 x 6.0 metre sheets and in 2.4
metre wide rolls. It is also available in purpose made sheets to suit your
project requirements. The mesh sheets are a welded square or rectangular
grid of D500L bars.
1. Trench mesh is normally specified by the number of wires used in either the top and/or bottom of the footing so
that the design cross-sectional areas given above are not often referred to. Common trench mesh strip widths are
200 mm (3 wires), 300 mm (4 wires), and 400 mm (5 wires). See AS2870.1
2. The steel grade for standard fabric and trench mesh is D500L.
3. Fabric configurations are not limited to the standard fabrics shown above. Fabric main wire spacings are the most
critical factor for special meshes, and detailers should check with Smorgon ARC before finalising a design using
any fabric not included in the list of standard fabrics.
4. Fabrics RF 63 and RF 53 have an internal mesh size of 300 mm x 300 mm. The sheet size is 6 m long by
2.3 m wide. The 100 mm closer wire spacings on the side reduce the minimum side lap to 100 mm, rather
than 300 mm. They are not available in every state.
5. Although the fabrics listed above are generally available ex-stock, we recommend that designers and users check
with their local Smorgon ARC office if they have any questions about properties or availability.
6. The RF (Ribbed Fabric) prefix is used to denote a D500L mesh to AS4671-2001. The RF prefix is well established
in the engineering community and avoids the confusion of the RL and SL designations.
Notes:
1. The mass of fabric per square metre is based on a piece cut from the interior of a full sheet which is one metre
square with equal overhangs on opposite sides.
2. Common trench mesh strip widths are 200 mm (3 wires), 300 mm (4 wires) and 400 mm (5 wires).
See AS2870.1, Residential Slabs and Footings Part 1- Construction, for applications.
3. Fabrics RF 63 and RF 53 have an internal mesh size of 300 mm x 300 mm. The sheet size is 6 m long by
2.3 m wide. The 100 mm closer wire spacings on the side reduce the minimum side lap to 100 mm, rather
than 300 mm. They are not available in every state.
4. Although the fabrics listed above are generally available ex-stock, we recommend that designers and users check
with their local Smorgon ARC office if they have any questions about properties or availability.
Table 25: Development length and laps for deformed wire fabric (AS4671 and AS3600)
AS4671, Clause 7.2.5 gives the minimum welded connection shear force
for mesh as 0.5 Rek.L As, that is, half the yield force of the largest bar at
the weld.
To develop the design stress of the wire (Rek.L As) at least two welded
intersections must be embedded (2 x 0.5 Rek.L As). To transfer this stress
from one sheet to another, a minimum overlap of two welded intersections
must be specified. These are the reasons for the requirements of Clause
13.2.3 of AS3600.
Each wire of welded wire fabric develops its stress by normal adhesive
bond with concrete together with bearing, against the concrete, of cross
wires welded transversly to it. Adhesive bond to the wire is usually
neglected for cross-wire spacings up to 200 mm. No advantage is given
to deformed wires. Most overseas Standards specify the minimum
overlaps of 200 mm or more because the weld-shear strength is limited to
0.3fsy.wire. Thus at least three, and often four, wires must be overlapped
leading to serious bunching.
Wire size. 4.0 4.75 6.0 6.75 7.6 8.55 9.50 10.65 11.90
mm Mm mm mm mm mm mm mm mm
25 d wire + 25 125 145 175 195 215 240 265 295 325
Table 26: Embedment length of one weld plus an overhang of 25 dwire + one weld + 25 mm
The most important requirement for structural safety of a slab is that the
correct reinforcement is placed in the direction of the span which controls
the strength characteristics.
However for minor structures, the reinforcement details are often not well
documented and steel fixers must be given additional instructions on the
sheet direction.
Overlap at side of sheet, rectangular All drawings should indicated the direction in which to place the
meshes, RF1218 to RF718, and longitudinal wires of fabric, and also illustrate how fabric sheets are to be
square mesh RF81 lapped.
Rectangular fabrics such a F718 and F818 require particular care when
detailing them.
Where suspended slabs have a span less than 6 metres, it is unusual that
fabric would need to be lapped at the end of a sheet.
If end laps are required, the actual length of the overhang should be
allowed for and specified, and a clear statement made on the drawings
Overlap at side of sheet, square whether or not the overhang is included in the lap unless the following
meshes edge side-lapping wires rules are observed:
RF102 to RF52, RF63 and RF53
1. Full width sheets are overlapped by the distance between the two
outermost edge wires.
2. When cut sheets are lapped, the outermost two wires are also
overlapped, and the length of the overhang is neglected.
Additional lap-splice strip. The Example of laps are given in Figure 50.
cross-wires are being spliced in this
example, so the cross-sectional area Specify the Fabric Position
(bar or wire sizes and spacing) must The next factor to be considered is to locate the fabric in the right position.
match. Fabric in the bottom of a slab must be supported on bar chairs from the
formwork.
Continuous bar chairs, such as the ARC “Goanna” chair, are the most
suitable here because they can be set out on the forms before the fabric is
placed and the weight of the fabric is evenly spread over many legs.
Thus, there is no need to place chairs under the steel that fixers are
standing on.
This example shows an Top reinforcement must be supported on high bar chairs, on high
INCORRECT method of lapping. “Goannas” or on “Deckchairs”.
Only one mesh is overlapped here
instead of two as required. Mesh Laps
The outermost wires of the lower
These laps are based on AS3600 and on AS2870.1. The wires should be
sheet are spaced at 100 mm. The
tied together to prevent slippage. For tying, the orientation of the sheets is
upper sheet has wires spaced at
not critical. That is, the lapped wires may be in the same layer or
200 mm. separated by the wires at right angles.
Additional strips or finger mesh must be used when it is critical that the
Figure 50: Mesh laps effective depth be maintained.
Page 58 The Smorgon ARC Reinforcement Handbook
Reinforcing Mesh
Wire size 4.00 4.75 6.00 6.75 7.60 8.55 9.50 10.65 11.90
Spacing mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m mm2/m
Nominal diameter of wire mm 4.00 4.75 6.00 6.75 7.60 8.55 9.50 10.65 11.90
Nominal area of one wire mm2/m 13 18 28 36 45 57 71 89 111
Area provided by the number of wires as shown on left
Number of wires mm2 mm2 mm2 mm2 mm2 mm2 mm2 mm2 mm2
2 wires 25 35 57 72 91 115 142 178 222
3 wires 38 53 85 107 136 172 213 267 334
4 wires 50 71 113 143 182 230 284 356 445
5 wires 63 89 142 179 227 287 355 556 556
6 wires 76 106 170 215 272 344 425 535 667
7 wires 88 124 198 251 318 402 496 324 778
8 wires 101 142 226 286 363 459 567 713 890
Table 29: Cross-sectional areas of engineer designed fabric
Notes:
1. The longitudinal wire spacing should be restricted to between 100 mm and 200 mm, although a 300 mm spacing
is acceptable provided the quantity of fabric can be manufactured economically for the project.
2. The longitudinal wire spacings given in Table 27 should be regarded as a practical manufacturing limitation to
conserve costs. The size of the cross wire should be not less than approximately one-half the diameter of the
longitudinal wire, and spaced at 200 mm or 300 mm centres. Cross wire size and spacing is determined by the
design requirements.
RF 62 (141)
RF 41 (126)
N12-1000 (110)
RF 63 (94)
The sources of the information are books published by the British Reinforced Engineering CO. Limited of Stafford,
England (BRC) up to 1950, and ARC Engineering CO. Pty. Ltd. (ARC) thereafter to 1973. Fabrics manufactured by
other Australian companies cannot be identified with certainty and are therefore not included.
Whilst the information given here is believed to be accurate, it is one thing to identify the notation given on a drawing
but it is an entirely different matter to be sure that the specified material was actually used.
The design drawings are the only guide to the quality of steel and concrete intended to be used. It is always possible
to test steel for yield stress, tensile strength, elongation, cross-sectional area (allowing for corrosion), etc. by removing
a sample from the structure. If the original diameter is difficult to determine because of corrosion, it may be better not
to proceed further.
Table 30 summarises the design yield stress of reinforcing steels. This should be adequate for most purposes using
present day analyses by limit state methods. Any attempt to compare the original working stress designs with AS3600
would require more information, probably not available, for little benefit in accuracy. In any case, to determine the
current structural adequacy requires application of current loading conditions.
The effective strength of steel does not decrease with time, however the contribution of the surrounding concrete can
be quite different from the original design specifications.
Notes:
1. Prior to 1960, the specified minimum yield stress of fabric was given as 70 000 pounds per square inch.
For refurbishment purposes, the tabulated value of 450 MPa is recommended.
2. Twisted bars can be identified by surface appearance. Remove untwisted ends (about 150 – 200 mm) before
splicing by end-butt welding or mechanical methods.
3. Intermediate Grade was rare and probably used only for projects designed in USA or designed to ASTM
standards for construction in Australia. Weldability is very doubtful and should not be considered.
4. Hard Grade was common in NSW, but unusual elsewhere. It is not weldable.
5. From 1988, AS3600 specified only a design yield stress of 400 MPa for deformed bars. This strength was not
manufactured until 1991 when AS1302 was amended.
Of greater concern may be the quality of the concrete. Again, if there is little evidence of excessive deflection, spalling
or rust, then the integrity of the structure is probably not in doubt for the loads it has carried in the past.
It is not well known that, until publication of AS3600, the fire resistance requirements of prior Standards was
determined from information available before 1949. This was before the introduction of cold worked bars in Australia
yet the rules were assumed to be satisfactory without amendment. It is suggested that the provisions of AS3600-
2001 be considered rather than using standards in vogue at the time of construction.
Wire spacing inches 2 in. 3 in. 4 in. 6 in. 8 in. 12 in.
Wire spacing, millimetres 50.8 76.2 101.6 152.4 203.2 304.8
Size Wire diameter Cross sectional area Steel crossing areas for wire spacing:-
ISWG (inches) (mm) Sq in. Sq mm mm2/m mm2/m mm2/m Mm2/m mm2/m mm2/m
7/0 0.500 12.70 0.1963 126.7 2494 1662 1247 831 623 416
6/0 0.464 11.79 0.1691 109.1 2147 1432 1074 716 537 358
5/0 0.432 10.97 0.1466 94.6 1861 1241 931 620 465 310
4/0 0.400 10.16 0.1257 81.1 1596 1064 798 532 399 266
3/0 0.372 9.45 0.1087 70.1 1380 920 690 460 345 230
2/0 0.348 8.84 0.0951 61.4 1208 805 604 403 302 201
1/0 0.324 8.23 0.0824 53.2 1047 698 524 349 262 175
1 0.300 7.62 0.0707 45.6 898 598 449 299 224 150
2 0.276 7.01 0.0598 38.6 760 507 380 253 190 127
3 0.252 6.40 0.0499 32.2 633 422 317 211 158 106
4 0.232 5.89 0.0423 27.3 537 358 268 179 134 89
5 0.212 5.38 0.0353 22.8 448 299 224 149 112 75
6 0.192 4.88 0.0290 18.7 368 245 184 123 92 61
7 0.176 4.47 0.0243 15.7 309 206 154 103 77 51
8 0.160 4.06 0.0201 13.0 255 170 128 85 64 43
9 0.144 3.66 0.0163 10.5 207 138 103 69 52 34
10 0.128 3.25 0.0129 8.3 163 109 82 54 41 27
12 0.104 2.64 0.0085 5.5 108 72 54 36 27 18
14 0.080 2.03 0.0050 32. 64 43 32 21 16 11
Table 31: Imperial standard wire gauges expressed as metric cross-sectional areas
Figure 52: 400Y bar obverse and reverse Figure 53: D500N bar reverse Figure 54: D500N bar obverse
Table 32: Rectangular – Mesh Fabrics. Only main wire details can be identified with any degree of certainty
Table 33: Square – Mesh Fabrics. Main wire and cross wire sizes, spacing and areas are the same
#9 (639)
N28 (620) Y28 (620)
#8 (510)
N24 (450) Y24 (450)
#7 (387)
#4 (129)
N12 (110) Y12 (110)
R10 (80)
#3 (71)
#2 (32)
R6 (30)
12.5 (122.7)
10.0 (78.5)
9.50 (70.9) 9.50 (70.9)
9.0 (63.6)
8.55 (57.4) 8.55 (57.4)
8.0 (50.3)
7.60 (45.4) 7.60 (45.4)
7.1 (39.6)
6.75 (35.8) 6.75 (35.8)
6.3 (31.2)
6.0 (28.3) 6.0 (28.3)
5.0 (19.6)
3.15 (7.8)
Square meshes
Area in sq mm
Deformed 500 MPa Deformed 500 MPa mesh Round 450 MPa mesh Round 450 MPa mesh
Ductility Grade
D500L mesh
F640 (532)
F81 (503)
RF81 (454) RF81 (454) F630 (460)
Rectangular meshes
Main wire area in sq mm
F303 (805)
F1018 (785)
RF1018 (709) RF1018 (709)
F304 (698)
F918 (636)
RF918 (574) RF918 (574) F305 (599)
F307 (422)
F718 (396)
RF718 (358) RF718 (358)
F308 (349)
F309 (299)
F310 (253)
AS3600-2001 considers bar chairs and spacers as embedded items. They are covered
by Clause 14.2. AS3600-2001 does not give any design guidelines for the type, spacing
or arrangement of reinforcement supports.
1. Durability is the most common form of failure for bar chairs. This is particularly prevalent
on the exposed underside of balconies. Wire bar chairs can cause rust spotting of the
concrete surface if care is not taken during construction. The choice of bar chair also
impacts on the durability of the concrete structure as it affects the cover to the
reinforcement.
For strength requirements, the bar chairs and spacers must hold the reinforcement in
position until the concrete has achieved initial set. The loads that the chairs can incur
include people walking over the reinforcement, stacked materials, mounded wet concrete
2. and vibration during the concrete placement. The bar chairs must also hold these loads
when subjected to heat. The forms can get as hot as 80ºC in northern Australia.
As bar chairs and spacers are placed against the form, they are usually visible upon close
inspection of the concrete surface. Some bar chairs are more visible than others as they
have a larger base area. Plastic bar chairs come in several colours, depending on the
manufacturer and the available plastic. Typical colours are black or grey, however white,
purple, green and many other colours are made.
2.Trench Mesh Supports - Plastic bar chairs for supporting trench mesh in strip footings.
4.
These chairs provide 50 mm of cover. The trench mesh supports clip onto
the trench mesh before lowering into the trench.
3. Fast Wheels - Plastic spacers for precast concrete and column applications.
These spacers are ideal for column cages where the cage is assembled then lowered
into position. Fastwheels are available in 15, 20, 25, 30, 40, 50 and 75 mm covers.
4. Clipfast Plastic Bar Chairs - Plastic bar chairs that clip onto the reinforcement.
They are available for bar and mesh reinforcement. Plastic bases are available for slab
5. on ground applications. As these chairs clip onto the reinforcement, they can be used in
vertical and top cover applications. They suit 15, 20, 25, 30, 35, 40, 45, 50, 60, 65 and
75 mm covers.
5. Plastic Tipped Wire Bar Chairs - These bar chairs are for suspended slab and
beam reinforcement being cast on timber or metal forms. The chair is made of wire and
each leg is plastic tipped. These are the most common bar chair used for suspended
slabs. They suit a large range of covers and slab thicknesses. Plastic tipped wire bar
chairs are available in 20, 25, 30, 35, 40, 45, 50, 60, 65, 70, 75, 80, 85, 90, 100, 110,
6. 120, 125, 130, 140, 150, 160, 170, 180, 190, 200, 210, 220, 230, 240, 250, 260, 280,
300, 320, 340 and 360 mm covers from the underside of the bar to the bottom form.
Metal bases are available for the plastic tipped wire bar chairs when used for slab on
ground applications.
7.
7. Plastic Continuous Bar Chairs - A continuous, 2 m long plastic bar chair for use in
suspended slabs. They are available in 20, 30, 40 and 50 mm covers.
8. Plastic Deck Spacers - Plastic deck spacers are for suspended slabs and beams cast
8a. on timber or metal forms. They are available for 20, 25, 30, 35, 40, 45, 50, 65, 75, 90,
100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 mm covers from the
underside of the bar to the bottom form. Spacers 50 mm and less are as shown in 8a.
Spacers 65 mm and taller are as shown in 8b.
9. Plastic Deck Chairs - Plastic deck chairs are ideal for suspended slabs. The design of
the chair accommodates both the bottom reinforcement and the top reinforcement from
the one chair. The base provides covers of 25, 30 and 40 mm cover to the bottom
reinforcement. The top clip is available to suit covers from 90 to 220 mm in 10 mm
8b.
increments from the underside of the bar to the bottom form.
10. Concrete Spacers - Concrete spacers are available for 25, 30, 35, 40, 45, 50, 55, 60,
65, 75 and 100 mm cover.
11. Heavy Duty Clip-On Chairs - These chairs are made of plastic and are suitable for most
formed applications. The chair can clip to N12 and N16 reinforcement. They are available
for 30, 35, 40, 45 and 50 mm cover when clipped to a N16 bar. The covers when clipped
to N12 bars are 34, 39, 44, 49 and 54 mm.
9. 12. Folded Mesh Spacers - Folded mesh in 2.4 metre lengths provides a fast and accurate
method for spacing layers of reinforcement. Folded mesh spacers are suitable for
separations between layers from 70 mm to 400 mm. Mesh is folded to order, hence the
height is made to suit the project.
13. Truss Spacers - Truss spacers are used in suspended slabs and are made in lengths
from 3 to 6 m. They are available in 80, 110, 150 and 190 mm heights.
10.
11.
12.
13.