Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (1 vote)
356 views

Nozzle Interference Error Solving

This document summarizes nozzle calculations for a vessel. It lists 6 nozzles with their MAWP, material thickness, weld size, and whether the area/stress calculations passed. It then checks for any interference between nozzles based on their location and diameter. Multiple nozzle checks are performed on a blind flange and no violations are found for spacing, areas, diameters, or distance to edge. The minimum vessel MAWP is 613.118 psig based on the nozzle calculations.

Uploaded by

Sakthi Vel
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
356 views

Nozzle Interference Error Solving

This document summarizes nozzle calculations for a vessel. It lists 6 nozzles with their MAWP, material thickness, weld size, and whether the area/stress calculations passed. It then checks for any interference between nozzles based on their location and diameter. Multiple nozzle checks are performed on a blind flange and no violations are found for spacing, areas, diameters, or distance to edge. The minimum vessel MAWP is 613.118 psig based on the nozzle calculations.

Uploaded by

Sakthi Vel
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PV Elite 2019 Licensee: VENVEL THERMAL & MECH.

DESIGNERS 1
FileName : ASME-DCN-2018
Nozzle Summary: Step: 74 1:56pm Apr 1,2019

Nozzle Calculation Summary:

Description | MAWP | Ext | MAPNC | UG-45 [tr] | Weld | Areas or |


| psig | | psig | | mm | Path | Stresses |
----------------------------------------------------------------------------------------------
D-CONDEN IN/OUT | 955.43 | ... | ... | OK | 7.80 | OK | Passed |
E1-LEVEL GAUGE1 | 828.79 | ... | ... | OK | 6.42 | OK | No Calc[*] |
E2-LEVEL GAUGE | 828.79 | ... | ... | OK | 6.42 | OK | No Calc[*] |
F-LEVEL RADAR | 613.12 | ... | ... | OK | 8.73 | OK | Passed |
B-COND. IN CFID | 861.44 | ... | ... | OK | 6.42 | OK | No Calc[*] |
C-RELIEF VALVE | 861.44 | ... | ... | OK | 6.42 | OK | No Calc[*] |
----------------------------------------------------------------------------------------------

MAWP Summary:
Minimum MAWP Nozzles : 613.118 Nozzle : F-LEVEL RADAR
Minimum MAWP Shells/Flanges : 828.792 Element : Shell- B36.10
Minimum MAPnc Shells/Flanges : 1190.049 Element : Blind flange App2
--------------------------------------------------------------------------
Computed Vessel M.A.W.P. : 613.118 psig

[*] - This was a small opening and the areas were not computed or
the MAWP of this connection could not be computed because
the longitudinal bending stress was greater than the hoop stress.

Note: MAWPs (Internal Case) shown above are at the High Point.

Warning: A Nozzle Reinforcement is governing the MAWP of this Vessel.

Check the Spatial Relationship between the Nozzles

From Node | Nozzle Description | Y Coordinate | Layout Angle | Dia. Limit |


| | mm | deg | mm |
------------------------------------------------------------------------------
10 | D-CONDEN IN/OUT | 0.000 | 0.000 | 150.000 |
20 | E1-LEVEL GAUGE1 | 616.000 | 180.000 | 98.325 |
20 | E2-LEVEL GAUGE | 260.000 | 180.000 | 98.325 |
40 | F-LEVEL RADAR | 0.000 | 0.000 | 230.000 |
40 | B-COND. IN CFID | 0.000 | 225.000 | 80.000 |
40 | C-RELIEF VALVE | 0.000 | 315.000 | 80.000 |

The nozzle spacing is computed by the following:


= Sqrt( ll² + lc² ) where
ll - Arc length along the inside vessel surface in the long. direction.
lc - Arc length along the inside vessel surface in the circ. direction

If any interferences/violations are found, they will be noted below.


No interference violations have been detected !

Checking Multiple Nozzles on Flat Head per ASME Sec. VIII Div. 1 UG-39

Comparing Nozzles on Element: Blind flange App2

UG-39 Average Nozzle Diameter and Ligament Checks:

Nozzle | Avg. | Head Dia.| Ligament | Min. dn |


Pair Description | dia. | /4 | Width | /4 |
| mm | mm | mm | mm |
-----------------------------------------------------------------
F-LEVEL RADAR & B-CON| 65.525 | 166.69 | 141.16 | 12.212 |
F-LEVEL RADAR & C-REL| 65.525 | 166.69 | 141.16 | 12.212 |
B-COND. IN CFID & C-R| 48.85 | 166.69 | 264.94 | 12.212 |
-----------------------------------------------------------------
PV Elite 2019 Licensee: VENVEL THERMAL & MECH. DESIGNERS 2
FileName : ASME-DCN-2018
Nozzle Summary: Step: 74 1:56pm Apr 1,2019

UG-39 Nozzle Spacing and Average Area Checks:

Nozzle | Center | Avg. dia.| Avg. Area | Avg. Area |


Pair Description | Spacing | * 1.25 | Available | Reqd. |
| mm | mm | mm² | mm² |
-------------------------------------------------------------------
F-LEVEL RADAR & B-CON| 230 | 81.906 | No Calc | No Calc |
F-LEVEL RADAR & C-REL| 230 | 81.906 | No Calc | No Calc |
B-COND. IN CFID & C-R| 325.27 | 61.062 | No Calc | No Calc |
-------------------------------------------------------------------

UG-39 Nozzle Diameter and Distance to Edge Checks:

Nozzle | Nozzle | Head Dia. | Distance | Nozzle |


Description | dia. | /2 | from Edge | dia./4 |
| mm | mm | mm | mm |
-------------------------------------------------------------------
F-LEVEL RADAR | 82.2 | 333.38 | 411.23 | 20.55 |
B-COND. IN CFID | 48.85 | 333.38 | 209.74 | 12.212 |
C-RELIEF VALVE | 48.85 | 333.38 | 209.74 | 12.212 |
-------------------------------------------------------------------

No Multiple Nozzle spacing violations have been detected !