•PRODUCT CATALOGUE• SECTION 3 – METHOD STATEMENT – SMART WALL PANEL
METHOD STATEMENT
Smart Wall Panel Insulation System
1. Pre - installation survey 2. SUBSTRATE PREPARATION
and preliminary work Before the start of thermal insulation work, it is
Application should be performed in the ambient and recommended to check the quality of the existing
substrate temperature ranging from +5°C to 55°C with substrate to assure perfect bonding performance
humidity below 80%. and system integrity. The substrate must be load-
bearing, dry and free from any substances that may
Provide external access scaffolding to the entire area weaken adhesion such as grease, shuttering oil,
which is to be done. A minimum gap of 400mm gap curing compounds, bitumen or dust.
should be maintained between the scaffolding and
the concrete wall. Supports such as bracing, props 02
P 01
•PRODUCT CATALOGUE• SECTION 3 – METHOD STATEMENT – SMART WALL PANEL
03
04
4. Installation of SW Panels
SW Panels are fixed by CT 85 adhesive and mechanical
fasteners. Approximately 5.00 litres of clean potable
water in a suitable container is to be arranged. To this
container, CT 85 adhesive needs to be added in small
increments, and a low speed drill with a mixing paddle
is used until the mixture is thoroughly blended.
P 02
•PRODUCT CATALOGUE• SECTION 3 – METHOD STATEMENT – SMART WALL PANEL
06
P 03
•PRODUCT CATALOGUE• SECTION 3 – METHOD STATEMENT – SMART WALL PANEL
P 04
QUALITY CONTROL
Quality Control Smart Wall Panel System (SIFS)
1. Material storage:
Verify adequacy of material storage areas and that materials are properly stored.
Insulation should be protected from moisture and direct sunlight during job and whilst site storage.
Pallets of Smart Wall panels are double packaged in a UV resistant polyethylene bag. This moisture
resistant package is designed for protection from the elements during flat-bed shipment from
factories to the site, and for storage on-site during construction phase. Outdoor storage for extended
periods of time requires additional breathable water proof tarpaulins and elevated storage above
ground level by a minimum of 4”.
2. Substrate conditions:
Verify that the substrate is correct, substrate condition is clean, dry, free from defects, in plane, and
verify substrate installation and attachment in conformance with manufacturer’s recommendations
(detailed in method statement)
3. Flashing:
Flashing is a vital component of wall construction that is intended to divert and direct water to the
exterior of the wall.
3.1. Note critical flashing locations on the structure and verify that flashing is present. Flashing must
be installed in compliance with the applicable building code, and at a minimum at the following
locations:
3.2. Verify that flashing end dams are incorporated into the flashing material beneath windows and
doors.
4.1.Backwrapping: Verify the presence and attachment of back wrap reinforcing mesh at system
terminations prior to the application of SW panels.
4.2. Adhesive application: Verify application of adhesive in the proper direction with the proper size
notched trowel.
• Verify full embedment of back wrap reinforcing mesh along edges—no voids or mesh color
visible.
• Verify installation of diagonal mesh strips at corners of all openings.
• Verify installation of High impact mesh with butt joints at areas indicated on drawings.
• Verify reveals reinforced with mesh and no excess base coat.
• Verify mesh overlaps of minimum 2-1/2”.
• Verify double mesh or Corner Mesh reinforcement at corners.
• Verify no mesh color visible in the completed base coat application.
• Verify finish application in advance of direct sunlight exposure and away from a wet edge.
• Verify consistency of texture and color with sample or mock-up.
• Verify finish not installed into or over construction joints.
4.7. Sealants
5. Final inspection
Subject to the terms outlined in this guarantee, GPI hereby guarantees the performance of Smart Wall Panel
system for a period of 10 (ten) years from the date of installation. The product(s) however must be properly
applied, using approved materials and applicators as per the manufacturer’s recommendations and applicable
building code regulations or applicable industry standards. Product(s) should be used within their shelf life and
be installed in accordance with written guidelines and specifications provided at the time of installation. For
valid claims presented under this warranty, GPI shall replace and/or repair over the life of this Guarantee up
to an aggregate amount equal to the amount paid for the supply.
EXCLUSIONS GPI is not responsible for the following acts, conditions or circumstances or any damage, which
may arise from there:
1. For structural failure or workmanship not in accordance with manufacturer’s instructions and the applicable
industry standards.
2. Normal wear and tear resulting from usage.
3. Loss due to delays or any other consequential damages.
4. Any new installation, repairs or other maintenance or construction on or through the Smart Wall Panel
system.
5. Damage caused due to falling objects.
6. Any adjacent or abutting buildings structure, improved or unimproved property or any component thereof
including but not limited to structural failure or damage, leakage or drainage.
7. Damage due to Vandalism.
8. Any deliberate or negligent acts omissions by the owner or any third party, either before, during or after
installation of the Smart Wall Panel system.
9. Exposure to any chemical or solution, fire, radiation.
10. Settlements, distortion, failure or cracking of the building deck, walls or foundations of the building.
11. Improper installation or failure of any material used over which the Smart Wall Panel system is installed.
12. Infiltration or condensation of moisture in, through or around the walls, copings, buildings structure, or
underlying or surrounding materials.
OTHER MATERIALS
DATA SHEETS
•PRODUCT CATALOGUE• SECTION4–DATASHEET–SMARTWALLPANEL(SMARTWALLADHESIVE85)
Data Sheet
Smart Wall Adhesive / Base coat – CT 85
Features:
> High adhesion to mineral substrates.
> Vapor permeable
> Resistant to weather conditions
> Flexible Manufactured for GPI by Henkel Polybit Industries Ltd.
P O Box 293, Umm Al Quwain, United Arab Emirates
> Reinforced with fibres www.henkelpolybit.com
P 05
•PRODUCT CATALOGUE• SECTION4–DATASHEET–SMARTWALLPANEL(SMARTWALLADHESIVE85)
Data Sheet
Smart Wall Corner Beads – SWCB 50
Description
It eliminates the need for the time consuming task of
rasping and double wrapping of corners to achieve a
smooth, plumb, and level corners. The nose allows
for straight corners, depth of finish and high impact
resistant. The absence of a rounded nose allows
the EIFS corner bead to lie perfectly flat on the two
adjoining walls that form the corner.
Technical Data
Colour White
P 13
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – SMART WALL CORNER BEADS – SWCB 50
Data Sheet
Acrylic Primer – CT 16
Application
Suitable for indoor and outdoor substrates use.
Before applying SW plaster, acrylic primer is also Application method
recommended for all type of concrete, fibrous Apply CT 16 directly with airless spray or paint brush.
cement, plasters, gypsum plasterboards, fibrous Depending on the site-specific drying conditions,
plasterboards, aerated and lightweight concrete. work can be continued after only 3 hours. After
Also, used for wood chipboards, gypsum plasters hardening, the surface must be scratchproof.
and firmly adhering paint coats.
After use, wash the tools out with water. Hardened
Substrate Preparation material can be removed with a solvent or paint
CT 16 primer can be used in general after thorough remover.
cleaning. Before application, any continuous rear Note: Use primer only in dry conditions at a
surface moisture must be eliminated. Fungi and temperature of +5 °C to +45 °C and below 80 %
moss must be removed before priming with primer. relative air humidity.
Technical Data
P 15
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – ACRYLIC PRIMER
Manufactured for GPI by Henkel Polybit Industries Ltd. P O Box 293, Umm Al Quwain, United Arab Emirates | www.henkelpolybit.com
Data Sheet
Smart Wall Finish Coat – SW FC
Description
Different finishes can be created by using different
tools such as trowels, sponges, or brushes. The art
in traditional rendering is the appearance of the top
coat. Different tradesmen have different finishing
styles producing different textures and decorative
effects. SW Finish coat is used for making thin-layer
plasters on concrete substrates, traditional plasters,
gypsum substrates and chipboards, gypsum
cardboards, etc. We recommend the application of
the SW Finish coat as facade plaster on the Smart
Wall panels.
Technical Data
Thickness 1.5 - 2 mm
VOC nil
P 19
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – SMART WALL FINISH COAT – SW FC
Data Sheet
Mechanical Anchors - SWP 100
Description
EIFS insulation wall fixing plate/fastener, also called EIFS
wall fastenering washer or anchor is made of high-impact
Polypropylene, assembled with different sizes of screws.
Plastic expansion dowel provide excellent mechanical
strength for the SW panels to substrate. Available in
various lengths as per insulation thickness. Minimum five
dowels are recommended with the standard size of Smart
Wall panel. Fastening application should be performed
once the CT 85 adhesive is fully cured. Fastener heads
should be flush with the insulation board surface and
patched with base coat.
Technical data
Length 100 mm
Units required 5 per board
Nail diameter 4.5 mm
Nail Material Steel
Head Material Polypropylene
Installation temperature 0 - 40O C
P 09
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – MECHANICAL ANCHORS – SWP 100
Characteristic loads
A Normal weight concrete C 12/15 acc. to EN 206-1 8 mm
A Normal weight concrete C 16/20 - C 50/60acc. to EN 206-1 60 mm
B Clay bricks (Mz) acc. to DIN 105 35 mm
B Solid lime sandstone (KS) acc. to DIN EN 106 25 mm
C Vertically perforated clay brick (Hlz) acc. to DIN 105bulk density 0.001 W/K
≥1.2 kg/dm3
C Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density A,B,C
≥0.9 kg/dm3
C Sand-lime perforated (KSL) acc. to DIN EN 106 ETA -11/0192
Application matrix
Insulation To allow for differences in thicknesses of build up
thickness (adhesive and existing render), (mm) Embedment depth = 25 mm (A, B, C)
(mm)
10 30 50 70 90 110
40 095 095
60 095 115 135
80 115 135 155 175 195
100 135 155 175 195 215 235
120 155 175 195 215 235 255
140 175 195 215 235 255 275
Data Sheet
Smart Wall Reinforcing Mesh – SWM 16O
Description
Fiber glass mesh reinforcement is a coated alkaline
resistant fiber glass fabric used for Smart Wall
rendering system that meets ASTM E2098. Fiber
glass mesh has several advantages – high tensile
strength, water-proof,and low elongation. Strength
and durability are a direct result of the weight
of the mesh. It is an ideal material for concrete
reinforcing in building Smart Wall system. It is used
in conjunction with CT 85 adhesive mortar and work
as a reinforcement for both vertical and horizontal
joints of Smart Wall panels.
P 11
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – SMART WALL REINFORCING MESH – SWM 160
Data Sheet
Starter Trac – SWT 50
Description
Can be used as a starter trac at the base of a wall.
Face return flange is 1” (25 mm) with striations
which provide a strong physical bond for the base
coat and perforations for bonding the base to the
substrate. Available with weep holes. Ideal for use
where a finished edge is exposed. 3”(76 mm) wide
nailing flange also has striations for extra bonding.
STWP-1 1” (25mm) 25
STWP-2 2” (51mm) 15
P 07
•PRODUCT CATALOGUE• SECTION 4 – DATA SHEET – STARTER TRAC - SWT 50
Drawings
CT85 BASECOAT
ACRYLIC PRIMER
MECHANICAL FASTENERS
EXTERIOR GRADE FINISH COAT
ACRYLIC PRIMER
MECHANICAL FASTENERS
EXTERIOR GRADE FINISH COAT
P 01
2. TERMINATION OF SMARTWALL PANEL WITH DISSIMILAR MATERIALS -
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
ACRYLIC PRIMER
STARTER TRAC
SKIRTING ( BY OTHERS )
P 02
4. TERMINATION OF SMARTWALL PANEL AT FLOOR LEVEL
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
MECHANICAL FASTENERS
ACRYLIC PRIMER
FOUNDATION LEVEL
CT85 BASECOAT
ACRYLIC PRIMER
P 03
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
CT85 BASECOAT
PIPE PENETRATIONS
ON SMARTWALL
MECHANICAL FASTENERS
CT85 BASECOAT
MECHANICAL FASTENERS
P 04
8. LIGHT FXTURES ON SMARTWALL
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
CT85 BASECOAT
MECHANICAL FASTENERS
ACRYLIC PRIMER
WINDOW
CT85 BASECOAT
MECHANICAL FASTENERS ACRYLIC PRIMER
WINDOW
Drawings
CT85 BASECOAT
CLOSED CELL BACKER ROD &
ELASTOMERIC SEALANT (PU)
ACRYLIC PRIMER
WINDOW
CT85 BASECOAT
ACRYLIC PRIMER
CLOSED CELL BACKER ROD &
ELASTOMERIC SEALANT (PU) EXTERIOR GRADE FINISH COAT
WINDOW
P 06
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
METAL FLASHING
WINDOW
HOLLOW CONCRETE BLOCK
ACRYLIC PRIMER
MECHANICAL FASTENERS
CT85 BASECOAT
WINDOW
HOLLOW CONCRETE BLOCK
MECHANICAL FASTENERS
CT85 BASECOAT
CT85 MORTAR
P 07
14. WINDOW SILL FLUSHED (TYPICAL)
•PRODUCT CATALOGUE• SECTION 5 – DRAWINGS
Drawings
CT85 BASECOAT
INSULATION FILLER
MECHANICAL FASTENERS
CT85 MORTAR
DETAIL - 'A'
SMARTWALL PANELS LAYOUT - TYPICAL
DETAIL - 'A'
MECHANICAL FASTENERS
STAGGERED JOINTS
P 08