Quick Installation Guide: ECW5211-L Enterprise Access Point
Quick Installation Guide: ECW5211-L Enterprise Access Point
ECW5211-L
Copyright Notice
This document is protected by USA copyright laws and other laws and is the property of
Edgecore Networks Corporation. You may not copy, reproduce, distribute, publish,
display, perform, or modify any part of this publication in any form or by any means
without prior written permission from Edgecore Networks Corporation. You may not alter
or remove any copyright or other notice from copies of the content. All other brand and
product names are claimed or registered marks of their respective companies or
organizations.
FCC CAUTION
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or
transmitter.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other
channels is not possible.
This device is restricted to indoor use when operated in the 5.15 to 5.25 GHz frequency range.
※ FCC requires this product to be used indoors for the frequency range 5.15 to 5.25 GHz to reduce the
potential for harmful interference to co-channel Mobile Satellite systems.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 28cm between the radiator & your body.
Quick Installation Guide
ECW5211-L ENGLISH
CE CAUTION
Hereby, Edgecore Networks Corporation declares that the radio equipment type ECW5211-L is in
compliance with Directive 2014/53/EU.
AT BE BG HR CY CZ DK
EE FI FR DE EL HU IE
IT LV LT LU MT NL PL
PT RO SK SI ES SE UK
This device is restricted to indoor use.
Model - ECW5211-L
The device has been tested and passed the requirements of the following standards, and hence fulfills the
EMC and safety requirements of RED within the CE marking requirement.
Radio: EN 300 328 V2.1.1, EN 301 893 V2.1.1
EMC: EN 301 489-1 V2.1.1, EN 301 489-17 V3.1.1
EMC: EN 55032:2015 + AC:2016 Class B, EN 55024:2010 + A1:2015 including the followings:
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Safety: EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
Caution
This declaration is only valid for configurations (combinations of software, firmware, and hardware)
provided and supported by 4ipnet Inc. The use of software or firmware not provided and supported by
4ipnet Inc. may result in the equipment no longer being compliant with the regulatory requirements.
Requirements in
AT/BE/BG/CZ/DK/EE/FR/DE/IS/IE/IT/EL/ES/CY/LV/LI/LT/LU/HU/MT/NL/NO/PL/PT/RO/SI/SK/TR/FI/SE
/CH/UK/HR. 5150MHz ~ 5350MHz is for indoor use only.
In order to ensure compliance with the exposure recommendations to electromagnetic fields, the device
should be used at a minimum distance of 28cm from the body.
Quick Installation Guide
ECW5211-L ENGLISH
第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、
加大功率或變更原設計之特性及功能。
第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即
停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通
信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
[警語內容]
使用此產品時應避免影響附近雷達系統之操作。
MPE [警語]
「電磁波曝露量 MPE 標準值 1mW/cm2,本產品使用時建議應距離人體 28cm」
減少電磁波影響,請妥適使用
Quick Installation Guide
ECW5211-L ENGLISH
①
Quick Installation Guide
ECW5211-L ENGLISH
Hardware Overview
②
Quick Installation Guide
ECW5211-L ENGLISH
③
Quick Installation Guide
ECW5211-L ENGLISH
Hardware Installation
1. Mount ECW5211-L.
(a) Mounting on a Wall
1. Use the included screws to attach two ceiling-mount T-bar clips to the back of ECW5211-L.
2. Push ECW5211-L onto the ceiling T-bar until it clicks securely in place.
④
Quick Installation Guide
ECW5211-L ENGLISH
3. Power on ECW5211-L.
There are two ways to supply power over to ECW5211-L.
a) Connect an IEEE 802.3af-compliant PSE device (e.g. a PoE switch) to the Eth1/PoE port of the AP with an
Ethernet cable.
b) Connect the 12V/1A power adapter to the DC power jack.
⑤
Quick Installation Guide
ECW5211-L ENGLISH
Initial Configuration
To set up the ECW5211-L for the first time, administrators need to perform initial configuration to assign an IP
address and other information necessary for the AP to communicate with the local gateways.
2. Launch a web browser and enter the default IP Address of the AP (192.168.1.10) in the address field.
Log in using default Username (admin) and Password (admin) on the Administrator Login Page:
⑥
Quick Installation Guide
ECW5211-L ENGLISH
3. System Overview page of the WMI will appear after login.
⑦
Quick Installation Guide
ECW5211-L ENGLISH
⑧
Quick Installation Guide
ECW5211-L ENGLISH
The following instructions are the basic steps to establish the wireless coverage of your network. The AP will
connect to the wired network through its Eth2 port and enable wireless access to your network.
Mode:
Static: Manually fill in appropriate values for the network interface (IP Address, Netmask, Default
Gateway, and Primary DNS Server) – in the example above, the AP is still using the default IP
address 192.168.1.10.
DHCP: If the deployment requires that the AP get a dynamic IP Address from the LAN, set Mode to
DHCP; Click SAVE to submit the changes.
⑨
Quick Installation Guide
ECW5211-L ENGLISH
Step 2. Activate the first SSID for Wi-Fi access
2.1) By default, one Service Set Identifier (SSID) is enabled with the Radio A (RF Card A) and one SSID is
enabled with the Radio B (RF Card B). As shown on the VAP Overview page (Home > Wireless > VAP
Overview), Virtual Access Point No.1 (VAP-1) profile represents the first SSID available.
Note:
⑩
Quick Installation Guide
ECW5211-L ENGLISH
2.2) Click on the State (Enabled) of VAP-1 to configure the profile. This will bring up the following VAP
Configuration page.
2.3) Select the specific VAP profile (in this case, “RF Card A : VAP-1”). The basic settings of the VAP are
collected in the profile as follows:
VAP: Disable or Enable this VAP.
Profile Name: Name of the VAP profile for identity / management purposes.
ESSID: Extended Service Set Identifier (ESSID) serves as an identifier for clients to associate with the
specific VAP.
⑪
Quick Installation Guide
ECW5211-L ENGLISH
Network Mode:
Bridge mode – the VAP operates transparently (i.e. no NAT, no DHCP) such that client
devices will be assigned a dynamic IP address from a DHCP server on the LAN side. The
source IP address of client traffic seen by the uplink gateway/switch will remain the original IP
address of the client (in this case, 192.168.1.31, as shown in the diagram below).
NAT mode – the VAP operates like a Network Address Translation (NAT) device with a
built-in DHCP server on this SSID such that client devices will be assigned a dynamic IP
address from the configured DHCP pool on this SSID. After NAT conversion, the source IP
address of client traffic seen by the uplink gateway/switch will be the IP address of the AP (in
this case, 192.168.1.10, as shown in the diagram below).
VLAN ID: Per-SSID VLAN tagging function – when enabled, clients’ traffic which enters the AP through
this SSID will be tagged with the configured VLAN ID.
DHCP Profile: Built-in DHCP Server profile; IP settings of DHCP Server are under Home > System >
DHCP Server.
CAPWAP Tunnel Interface: Three states indicating the connectivity between AP and Controller, when
AP is managed by Controller –
Disable (No Tunnel): the AP is operating with no CAPWAP Tunnel connection to the
Controller
Split Tunnel: the AP passes only "control" traffic to the Controller via the CAPWAP Tunnel;
i.e. "data" traffic will go out locally without passing through the Tunnel
Complete Tunnel: the AP passes both "control" and "data" traffic to the Controller via the
CAPWAP Tunnel
⑫
Quick Installation Guide
ECW5211-L ENGLISH
For initial configuration, you might want to change the default basic settings shown below:
RF Card A – 2.4 GHZ, 802.11g+802.11n, Antenna Mode 2T2R, Channel Width 40 MHz, Channel 6
RF Card B – 5 GHz, 802.11ac, Antenna Mode 2T2R, Channel Width 80 MHz, Channel 36
You can make changes to other settings at a later time.
Well done! After a system restart, the AP should be able to operate with these settings.
⑬
Quick Installation Guide
ECW5211-L ENGLISH
After ECW5211-L's network configuration is completed, please remember to change the IP Address of
your PC Connection Properties back to its original settings in order to ensure that your PC functions
properly in its real network environments.
P/N: V34320180420