Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

OM ARxK-B OMT0015EN PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Doc. No.

AR∗-OMT0015

PRODUCT NAME

REGULATOR

MODEL/ Series

AR20K-(F,N)01~
~(F,N)02(B,E,G,H,M)(-1,N,R,Y,Z)-B
AR25K-(F,N)02~
~(F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B
AR30K-(F,N)02~
~(F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B
AR40K-(F,N)02~
~(F,N)04(B,E,G,H,M)(-1,N,R,Y,Z)-B
AR40K-(F,N)06(B,E,G,H,M)(-1,N,R,Y,Z)-B
AR50K-(F,N)06~
~(F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B
AR60K-(F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B
Contents
PAGE
1. SAFETY INSTRUCTIONS 1~4

2. APPLICATION 5

3. SPECIFICATIONS 5

4. HOW TO ORDER 6

5. TROUBLESHOOTING 7

6. CONSTRUCTION / PARTS LIST 8~9

7. REPLACEMENT PROCEDURE 10~12

8. DISASSEMBLY DRAWING 13~14

9. DIMENSIONS 15
REGULATOR
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC),
Japan Industrial Standards (JIS)*1) and other safety regulations*2).
*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems
ISO 4413: Hydraulic fluid power -- General rules relating to systems
IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots -- Safety
JIS B 8370: General rules for pneumatic equipment.
JIS B 8361: General rules for hydraulic equipment.
JIS B 9960-1: Safety of machinery – Electrical equipment for machines. (Part 1: General requirements)
JIS B 8433-1993: Manipulating industrial robots - Safety. etc.
*2) Labor Safety and Sanitation Law, etc.

Caution Operator error could result in injury or equipment damage.

Warning Operator error could result in serious injury or loss of life.

Danger In extreme conditions, there is a possibility of serious injury or loss of life.

Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or
decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific
equipment must be decided by the person who designs the equipment or decides its specifications based on
necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who
has determined its compatibility with the product.
This person should also continuously review all specifications of the product referring to its latest catalog
information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
The inspection and maintenance of machinery/equipment should only be performed after measures to prevent
falling or runaway of the driven objects have been confirmed.
When the product is to be removed, confirm that the safety measures as mentioned above are implemented
and the power from any appropriate source is cut, and read and understand the specific product precautions
of all relevant products carefully.
Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1) Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
2) Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,
vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other
applications unsuitable for the standard specifications described in the product catalog.
3) An application which could have negative effects on people, property, or animals requiring special safety
analysis.
4) Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a
mechanical protective function, and periodical checks to confirm proper operation.

1
REGULATOR
Safety Instructions
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications
or a contract if necessary.
If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements


The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance
Requirements”.
Read and accept them before using the product.

Limited warranty and Disclaimer


The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Also, the product may have specified durability, running distance or replacement parts. Please
consult your nearest sales branch.

For any failure or damage reported within the warranty period which is clearly our responsibility, a
replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.

Prior to using SMC products, please read and understand the warranty terms and disclaimers noted
in the specified catalog for the particular products.

Compliance Requirements
When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and
Industry (Foreign Exchange and Foreign Trade Control Law).

Caution
SMC products are not intended for use as instruments for legal metrology.
Products that SMC manufactures or sells are not measurement instruments that are qualified by pattern
approval tests relating to the measurement laws of each country.
Therefore, SMC products cannot be used for business or certification ordained by the measurement laws of
each country.

2
Precautions for design
! WARNING
① External parts including the bonnet, handle, cover (Material: polyacetal) are made of resin.
Organic solvents including synthetic fluid, chemicals including acetone, alcohol, ethylene
chloride, sulphuric acid, nitrate, hydrochrolic acid, cutting oil, kerosene, gasoline, lock
material of screw are harmful. Do not use the regulator where containing those.
② Consult SMC if no leakage is allowed due to the environment, or operating fluid is not air.
③ Protect from ultra violet ray and radiation heat by shield.
④ A safety device needs to be installed if output pressure is exceeding the set pressure,
otherwise this can cause the breakage of outlet device and equipment or malfunction.

! CAUTION
① The use outside specifications is prohibited.
② Air consumption from release port is 0.1L/min(ANR) or less.
Selection
! WARNING
① Mineral grease used on internal surfaces and packing may leak to the outlet. Please
contact SMC if this is a problem.
② Long absence of operation or operation with outlet circuit sealed or balance circuit may
cause pressure fluctuation in outlet set pressure. Please consult SMC if this is a problem.
③ Set pressure of outlet pressure shall be 85% or less of inlet pressure. Pressure over 85%
makes operation susceptible to flow and inlet pressure which lead to cause unstable
operation.
④ Maximum set pressure range in the spec. has margin. Pressure set may be higher than
the maximum value.
⑤ If regulator is used with circuit which requires high exhaust sensitivity or set precision,
please consult SMC.

Installation
! WARNING
① Connect the regulator ensuring the direction of "1" (IN) and "2" (OUT) for air direction or an
arrow. Wrong connection may cause malfunction.
② Install with enough space around regulator to perform regular maintenance and operation.
The required space is shown on 「11. Dimensions」 (P15).
③ Do not drop nor apply impact during transportation or installation. These lead to cause
precision failure of pressure.
④ Do not install in areas of high humid or high temperature. Or pressure gauge may
malfunction.

Adjustment
! WARNING
① Adjust the pressure adjusting handle ensuring correct inlet pressure and outlet pressure.
Excessive rotation may cause damage to internal parts.
② Operate the pressure adjusting handle manually. Tools may break the handle.
! CAUTION
① Check inlet pressure before setting up.
② Be sure to unlock the handle before adjusting the pressure and lock it after setting the
pressure. Failure to follow this procedure can damage the handle and the outlet pressure
may fluctuate.
・Pull the pressure regulator handle to unlock. (You can visually verity this with the "orange
mark" that appears in the gap.)

3
・Push the pressure regulator handle to lock. When the handle is not easily locked, turn it left
and right a little and then push it. (When the handle is locked, the "orange mark", i.e., the
will disappear.)
③ For the regulator with the pressure gauge, do not apply pressure exceeding the maximum
scale of the pressure gauge in order to protect the gauge.
④ Adjust pressure incrementally. Pressure may become lower than set pressure if adjusted by
decreasing the value. Rotate the handle clockwise to raise the set pressure.
Counterclockwise to reduce the pressure. Moreover, please lock the handle after setting
pressure.
⑤ Outlet pressure may rise if eliminate the inlet pressure after pressure setting and supply
pressure again. The pressure becomes close to the set pressure after air is consumed in
outlet.
⑥ Outlet pressure may change if regulator is used for long periods. Please confirm set pressure
regularly.
Piping
! WARNING
① Blow out or clean piping before piping to eliminate swarf, cutting oil, solid foreign material.
Contamination of piping may cause damage or malfunction.
② When installing piping, avoid chips and sealing materials from piping screws entering the
inside of equipment. Or malfunction may occur. When use sealing tapes, leave 1.5~2
threads of the end of thread exposed.
③ Hold the female screw side and screw in piping with recommended tightening torque.
Insufficient tightening torque lead to cause loose piping or sealing failure. Excessive torque
may lead to cause screw breakage. Tightening without holding female screw side applies
excessive force to the piping bracket which lead to cause breakage.
   : ・
Recommended torque unit N m
Screw 1/8 1/4 3/8 1/2 3/4 1
Torque ~
3 5 ~
8 12 ~ 15 20 ~
20 25 28 30~ ~
36 38
④ Do not apply any torsional moment, or bending moment except the weight of the regulator
itself. External piping needs to be supported separately. Hard piping like steel tube is
susceptible to excessive moment load or vibration. Insert the flexible tube to cancel the
influence.

Air Source
! WARNING
① Use clean air. Compressed air containing chemicals, organic solvent, synthetic oil or corrosive
gas may lead to cause breakage of parts or malfunction.
② Air containing too much moisture may cause malfunction. Install the air drier or the aftercooler
before the regulator.

Maintenance
! WARNING
① Maintenance and checks should be done by following the procedure in the operation manual.
Incorrect handling of the product may cause breakage or malfunction of the equipment or
device.

! CAUTION
① If the first operation is performed and defective setting and the exhaust leakage is found, it is
likely there is foreign object in an internal valve sliding surface or an internal valve seat part.
Failure to remove these parts may cause damage to internal parts.

4
2. APPLICATION
This product aims at controlling the pressure of air lines.
Built in counterflow function allows outlet pressure to be released to inlet side when inlet pressure becomes
lower than outlet pressure to specified extent.

3. SPECIFICATIONS
Model AR20K-B AR25K-B AR30K-B AR40K-B AR40K-06-B AR50K-B AR60K-B
Port size 1/8,1/4 1/4,3/8 1/4,3/8 1/4,3/8,1/2 3/4 3/4,1 1
Gauge port size Note1) 1/8
Fluid Air
Ambient and fluid
-5 ~ 60℃ (Should be no freezing)
temperature
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Note2)
Set pressure range 0.05 ~ 0.85 MPa
Construction Relieving type
Mass (kg) 0.16 0.21 0.29 0.44 0.47 1.17 1.22
Note 1) Square embedding type pressure gauge, without pressure gauge mounting threads.
Note 2) Set the inlet pressure 0.05MPa or higher than the set pressure.

5
4. HOW TO ORDER

AR 30 K - 03 BG - -B
1 2 3 4 5 6

1
Symbol Description Body size
20 25 30 40 50 60

2 Reverse flow function K With reverse flow function ● ● ● ● ● ●


● ● ● ● ● ●
● ● ● ● ● ●
Nil Rc
3
● ● ● ● ● ●
Thread type N NPT


F G

● - - - - -
● ● ● ● - -
01 1/8

- ● ● ● - -
02 1/4

- - - ● - -
03 3/8
4 Port size
- - - ● ● -
04 1/2

- - - - ● ●
06 3/4


10 1

● ● ● ● ● ●
● ● ● ● ● ●
Nil Without mounting option

● ● ● ● - -
a Mounting B With bracket


H With set nut (for panel mounting)
Option

5
● ● ● ● ● ●
● ● ● ● ● ●
Nil Without pressure gauge

● ● ● ● ● ●
Pressure E Square embedding type pressure gauge (with limit indicator)
b
● ● ● ● ● ●
gauge G Round type pressure gauge (with limit indicator)


M Round type pressure gauge (with colour zone)

● ● ● ● ● ●
● ● ● ● ● ●
Nil 0.05 to 0.85 MPa setting
c Set pressure

1 0.02 to 0.2 MPa setting

● ● ● ● ● ●
● ● ● ● ● ●
Exhaust Nil Relieving type
d


mechanism N Non-relieving type
Semi-standard

Flow direction: Left to right ● ● ● ● ● ●


● ● ● ● ● ●
Nil
6 e Flow direction


R Flow direction: Right to left

● ● ● ● ● ●
● ● ● ● ● ●
Nil Downward
f Handle


Y Upward

Name plate, pressure gauge: MPa ● ● ● ● ● ●


● ● ● ● ● ●
Nil
g Pressure unit
Z Name plate: psi, Pressure gauge: MPa / psi
※ Please refer to the catalog when you select the model.

6
5. TROUBLESHOOTING
Refer to 「6. CONSTRUCTION / PARTS LIST」 (P8 to P9), 「8. DISASSEMBLY DRAWING」 (P13 to P14).
TROUBLE
POSSIBLE CAUSE REMEDY
DEMARCATION PHENOMENON
Pressure is not 1. Opposite flow direction or opposite 1. Check flow diretion and install the
regulated. installation of regulator. regulator correctly if wrong.
2. Adjust spring is damaged. 2. Replace the adjust spring.
3. Valve spring is damaged. 3. Replace the valve spring.
4. Foreign materials caugth in valve seat 4. Remove the valve guide and clean valve
or valve "O" ring. seat or valve "O" ring. Grease up after
washing the sliding surface of valve "O"
ring.
5. Valve rubber seat is damaged. 5. Replace the valve.
6. Foreign materials caugth in the check 6. Replace the check valve assembly.
Pressure valve seat.
Set pressure does 1. Foreign materials caugth in valve seat 1. Remove the valve guide and clean valve
not return to zero or valve "O" ring. seat or valve "O" ring. Grease up after
when pressure washing the sliding surface of valve "O"
handle is ring.
loosened. 2. Valve rubber seat is damaged. 2. Replace the valve.
3. Foreign materials caugth in the check 3. Replace the check valve assembly.
valve seat.
4. Valve spring is damaged. 4. Replace the valve spring.
5. Valve adheres to the valve guide. 5. Wash the sliding surface of valve "O" ring
and grease up.
Air leaks from the 1. Diaphragm is damaged. 1. Replace the diaphragm assembly.
bonnet exhaust 2. Foreign material is caught in the 2. Clean the relieving valve seat, or replace
port. relieving valve seat. the diaphragm assembly.
3. Foreign materials caugth in valve seat 3. Remove the valve guide and clean valve
or valve "O" ring. seat or valve "O" ring. Grease up after
washing the sliding surface of valve "O"
ring.
4. Valve rubber seat is damaged. 4. Replace the valve.
Air leaks
5. Foreign materials caugth in the check 5. Replace the check valve assembly.
valve seat.
6. Back pressure exceeding the set 6. Revise the air circuit so that back
pressure is applied to the outlet. pressure does not exceed the set
pressure.
Air leaks between 1. Loosened bonnet. 1. Fasten the bonnet.
the bonnet and 2. Diaphragm is damaged. 2. Replace the diaphragm assembly.
the body.
The back flow 1. Foreign materials caught in check 1. Replace the check valve assembly.
Back flow mechanism does valve seat.
mecha-nism not operate. 2. Check valve adheres to the check 2. Replace the check valve assembly.
valve assembly.
Note) The grease used recommends JX Nippon oil & Energy corporation diamond multipurpose No.2.

7
6. CONSTRUCTION / PARTS LIST
AR20K-B /AR25K-B/AR30K-B

Component Parts
No. Description Model No. Material Note
① Body AR20K-B / AR25K-B / AR30K-B Aluminium die cast Urban white 1
② Bonnet AR20K-B / AR25K-B / AR30K-B Polyacetal Urban white 1

Option / Replacement Parts
Thread Option Part No.
No. Description Material
Type Symbol Specification AR20K-B AR25K-B AR30K-B
③ Valve - - HNBR AR20P-410S AR25P-410S AR30P-410S
④ Diaphragm assembly - - Weatherproof NBR AR20P-150AS AR25P-150AS AR30P-150AS
- N Non-relieving type Weatherproof NBR AR20P-150AS-N AR25P-150AS-N AR30P-150AS-N
⑤ Valve guide assembly - - Polyacetal / NBR AR20P-050AS AR25P-050AS AR30P-050AS
⑥ Note1)
Bracket assembly - - Steel plate / Polyacetal AR23P-270AS AR28P-270AS AR33P-270AS
⑦ Set nut - - Polyacetal AR23P-260S AR28P-260S AR33P-260S
⑧ Note2)
Square embedding type - - GC3-10AS
pressure gauge
Rc
1 0.2MPa setting - GC3-4AS
- - GC3-10AS
1 0.2MPa setting - GC3-4AS


Imperial unit
Z Name plate: psi GC3-P10AS-X30
NPT Pressure gauge: MPa / psi
Imperial unit
1Z
Name plate: psi
Pressure gauge: MPa / psi
- GC3-P4AS-X30
0.2MPa setting
- - GC3-10AS
G
1 0.2MPa setting - GC3-4AS
⑨ Pressure gauge cover - - - GC3P-010AS
⑩ Round type pressure gauge - - G36-10-01
Rc
1 0.2MPa setting - G36-4-01
- - G36-10-N01
1 0.2MPa setting - G36-4-N01


Imperial unit
Z Name plate: psi G36-P10-N01-X30
NPT Pressure gauge: MPa / psi
Imperial unit
1Z
Name plate: psi
Pressure gauge: MPa / psi
- G36-P4-N01-X30
0.2MPa setting
- - G36-10-01
G
1 0.2MPa setting - G36-4-01
Round type pressure gauge - - G36-10-01-L
(with colour zone)
Rc
1 0.2MPa setting - G36-4-01-L
- - G36-10-N01-L
NPT
1 0.2MPa setting - G36-4-N01-L
- - G36-10-01-L
G
1 0.2MPa setting - G36-4-01-L
⑪ Pressure gauge adaptor Rc - ARP20P-310AS-01
assembly NPT - Aluminium die cast ARP20P-310AS-N01
G - ARP20P-310AS-F01
⑫ Plug assembly Rc - - ARP20P-320AS-01
NPT - - ARP20P-320AS-N01
G - - ARP20P-320AS-F01
⑬ Plug Rc - AR20P-370AS-01
NPT - PBT RESIN AR20P-370AS-N01
G - AR20P-370AS-01
⑭ Check valve assembly - - - AR23KP-020AS
⑮ Check valve plug assembly - - - AR20KP-090AS

Note 1 Bracket and Set nut assembly.
) ( )
Note 2 With O ring 1 piece and Mounting screws 2 pcs . ( )
) 「
Note 3 The number in the table is corresponding to the number in structural drawing (avobe-mentioned figure) and 8.Disassembly drawing (P13 to P14).」
8
AR40K-B /AR50K-B/AR60K-B

Component Parts
No. Description Model No. Material Note
① Body AR40K-B / AR40K-06-B / AR50K-B / AR60K-B Aluminium die cast Urban white 1

② Bonnet
AR40K-B / AR40K-06-B
AR50K-B / AR60K-B
Polyacetal
Aluminium die cast
Urban white 1

Option / Replacement Parts
Thread Option Part No.
No. Description Material
Type Symbol Specification AR40K-B AR40K-06-B AR50K-B AR60K-B
③ Valve - - HNBR AR40P-410S AR50P-410S AR60P-410S
④ Diaphragm assembly - - Weatherproof NBR AR40P-150AS AR50P-150AS
- N Non-relieving type Weatherproof NBR AR40P-150AS-N AR50P-150AS-N
⑤ Valve guide assembly - - Polyacetal / NBR AR40P-050AS AR50P-050AS AR60P-050AS
⑥ Note1)
Bracket assembly - - Steel plate / Polyacetal AR43P-270AS Note2)
AR52P-270AS
⑦ Set nut - - Polyacetal AR43P-260S -
⑧ Note3)
Square embedding type - - GC3-10AS
pressure gauge
Rc
1 0.2MPa setting - GC3-4AS
- - GC3-10AS
1 0.2MPa setting - GC3-4AS


Imperial unit
Z Name plate: psi GC3-P10AS-X30
NPT Pressure gauge: MPa / psi
Imperial unit
1Z
Name plate: psi
Pressure gauge: MPa / psi
- GC3-P4AS-X30
0.2MPa setting
- - GC3-10AS
G
1 0.2MPa setting - GC3-4AS
⑨ Pressure gauge cover - - - GC3P-010AS
⑩ Round type pressure gauge
Rc
- - G46-10-01
1 0.2MPa setting G46-4-01
- - G46-10-N01
1 0.2MPa setting - G46-4-N01


Imperial unit
Z Name plate: psi G46-P10-N01-X30
NPT Pressure gauge: MPa / psi
Imperial unit
1Z
Name plate: psi
Pressure gauge: MPa / psi
- G46-P4-N01-X30
0.2MPa setting
- - G46-10-01
G
1 0.2MPa setting - G46-4-01
Round type pressure gauge - - G46-10-01-L
(with colour zone)
Rc
1 0.2MPa setting - G46-4-01-L
- - G46-10-N01-L
NPT
1 0.2MPa setting - G46-4-N01-L
- - G46-10-01-L
G
1 0.2MPa setting - G46-4-01-L
⑪ Pressure gauge adaptor Rc - ARP20P-310AS-01
assembly NPT - Aluminium die cast ARP20P-310AS-N01
G - ARP20P-310AS-F01
⑫ Plug assembly Rc - - ARP20P-320AS-01
NPT - - ARP20P-320AS-N01
G - - ARP20P-320AS-F01
⑬ Plug Rc - AR20P-370AS-01
NPT - PBT RESIN AR20P-370AS-N01
G - AR20P-370AS-01
⑭ Check valve assembly - - - AR23KP-020AS
⑮ Check valve plug assembly - - - AR20KP-090AS
Note 1 ) Bracket and Set nut assembly.
Note 2 ) Bracket and Mounting screws(2 pcs) assembly.
Note 3 ) With O ring (1 piece) and Mounting screws(2 pcs).
Note 4 ) The number in the table is corresponding to the number in structural drawing (avobe-mentioned figure) and 「8.Disassembly drawing」 (P13 to P14).
9
7. REPLACEMENT PROCEDURE
! WARNING
 Before replacement, ensure that the regulator is not pressurized.
 Rotate the pressure adjusting handle to zero.
Replace refering to “8.DISASSEMBLY DRAWING” (P13 to P14).
 After replacement, ensure that specified function is satisfied and external leakage is not found before starting operation.
1) Diaphragm assembly
Applicable model Process Procedure Tools Check item
1) Remove the bonnet.
Disassembly
Rotate the set screw counterclockwise with cross Cross pointed
pointed driver to remove the bonnet from the driver

body.
2) Remove parts in order of the pressure adjusting
screw assembly, pressure adjusting spring, and
the diaphragm assembly.
Please be noted that the diaphragm assembly
- -
adheres to the bonnet if disassemble parts with
the handle facing downwards.
AR20K-B
Assembly 3) Mount parts to the body in order of the diaphragm
AR25K-B
assembly, pressure adjusting spring, and pressure
AR30K-B Direction of diaphragm
AR40K-B
adjusting screw.
Mind the direction of the diaphragm assembly and
- assembly and pressure
AR50K-B adjusting screw assembly.
pressure adjusting screw assembly. See attached
AR60K-B
disassembly drawing.
4) Mount the bonnet to the body.
Mount the bonnet to the body, and settle it roughly Tightening torque
with four(4) set screws with a cross pointed driver. AR20K-B 2.35±0.3 N・m
Then, Tighten screws diagonally with the AR25K-B 2.35±0.3 N・m
Cross pointed
tightening torque in the check item to settle. AR30K-B 2.35±0.3 N・m
driver
AR40K-B 3.5±0.3 N・m
AR50K-B 3.5±0.3 N・m
AR60K-B 3.5±0.3 N・m

2) Valve guide assembly, valve


Applicable model Process Procedure Tools Check item
1) Remove the cap.
Disassembly
Insert the small screw driver in the gap between Small driver -
the body and the cap and dig up the cap.
2) Remove the cover.
Circular pliers
Insert the circular pliers to two holes of the cover
Nominal:125

and rotate 45 degree, and lift it.
3) Remove the valve guide assembly.
Hold the valve guide with a small pliers, and lift.
Small pliers -
4) Remove the valve spring. - -
5) Remove the valve. - -
AR20K-B
Assembly 6) Mount the valve. Positioning the stem
AR25K-B
Mate the stem convex and the valve center hole.
- and the valve (centering).
AR30K-B
7) Mount the valve spring.
AR40K-B
Insert the valve spring to the valve hole.
- -
AR50K-B
8) Mount the assembly of the valve guide and the
AR60K-B
cover.
Mate the notch of the body cover hole and the Circular pliers
detent of the cover. Then push the assembly of Nominal:125

them. Insert the circular plier to two holes of the
cover to rotate 45 degree to settle.
9) Mount the cap. Orientation of the body
Mate the convex of the body cover and the and
concave of the cap, and push them in to settle. - the cap.
Ensure the end of the body and the cap are Body end and the cap are
almost flat. almost flat.

10
3) Bracket assembly, panel mount
Applicable model Process Procedure Tools Check item
Assembly 1) Mount the parts to the bracket (panel).
Mate the bracket (panel) concave and the bonnet - -
convex to mount the bracket.
2) Settle the bracket (panel) with set nut.
AR20K-B
Rotate the set nut clockwise with a hook spanner Hook spanner
AR25K-B
to settle the parts to the bracket (panel). Nominal Tightening torque
AR30K-B
See check item for tightening torque. AR20K-B 34/38 AR20K-B 2.0±0.2 N・m
AR40K-B
Set nut knurling surface shall face the bracket. AR25K-B 40/42 AR25K-B 2.5±0.2 N・m
When mounting with bracket, set nut tightened AR30K-B 52/55 AR30K-B 3.5±0.3 N・m
manually is adequate fir general used. AR40K-B 52/55 AR40K-B 4.0±0.4 N・m

Assembly 1) Mount the product to the bracket.


AR50K-B Hexagon spanner Reference tightening torque:
(Bracket Two mounting screws are tightened by hexagon
AR60K-B assembly) Nominal:5 2.6 N・m
spanner for holding.

4) Square embedding type pressure gauge


Applicable model Process Procedure Tools Check item
1) Remove the pressure gauge cover.
Disassembly
Rotate the pressure gauge cover 15 degree
- -
counterclockwise to pull out the pressure gauge
cover.
2) Remove the pressure gauge.
Rotate two set screws counterclockwise with cross Cross pointed

pointed driver to remove the pressure gauge and driver
two set screws.
AR20K-B Assembly 3) Ensure "O" ring is mounted to the pressure gauge.
AR25K-B Mount "O" ring to the pressure gauge if the ring fall - Presence of "O" ring
AR30K-B off.
AR40K-B 4) Mount the pressure gauge.
AR50K-B Rotate two set screws clockwise with cross Cross pointed Tightening torque:
AR60K-B pointed driver to set screws temporary. Then settle driver 0.6±0.05 N・m
them with tightening torque in check item.
5) Mount the pressure gauge cover.
Insert the pressure gauge mating two detent of the
pressure gauge and holes for them so that the
arrow of the pressure gauge cover comes upper - -
right. Rotate the pressure gauge cover 15 degree
opposite to the arrow to mount the pressure
gauge.

5) Round type pressure gauge


Applicable model Process Procedure Tools Check item
Disassembly 1) Remove the pressure gauge. Spanner
Hold the pressure gauge with a spanner on the Nominal:
spanner flat. Then, rotate the gauge AR20K-B
counterclockwise to remove the gauge. AR25K-B
AR30K-B -
12
AR40K-B
  AR50K-B
AR60K-B
AR20K-B
AR25K-B
Assembly 2) Rap the pressure gauge thread with the seal tape
AR30K-B Wrap seal tape leaving 1.5
leaving 1.5 to 2 threads from the end. -
AR40K-B to 2 threads.
AR50K-B
3) Mount the pressure gauge. Spanner
AR60K-B
Hold the pressure gauge on the spanner flat with a Nominal: Tightening torque:
spanner, and rotate it clockwise to mount the AR20K-B AR20K-B
circular pressure gauge. AR25K-B AR25K-B
See Check item for tightening torque of pressure AR30K-B AR30K-B
12 3~ 5 N ・ m
gauge. AR40K-B AR40K-B
AR50K-B AR50K-B
AR60K-B AR60K-B

11
6) Pressure gauge adaptor assembly, Plug assembly
Applicable model Process Procedure Tools Check item
Disassembly 1) Remove the plug. Spanner
Insert the hexagon spanner to hexagon hole of Nominal:
hexagon plug. Rotate the plug counterclockwise to AR20K-B
remove the plug. AR25K-B
AR30K-B -
4
AR40K-B
AR50K-B
AR60K-B

2) Remove the pressure gauge adaptor.


Rotate two set screws counterclockwise with cross Cross pointed

pointed driver to remove the pressure gauge and driver
AR20K-B
two set screws.
AR25K-B
Assembly 3) Confirm pressure gauge adaptor has "O" ring. If
AR30K-B - -
not, mount "O" ring.
AR40K-B
4) Mount pressure gauge adaptor.
AR50K-B
Rotate two screws clockwise by Phillips driver to Cross pointed
AR60K-B Tightening torque:
fix pressure gauge adaptor. driver
0.6±0.05 N・m
See Check item for tightening torque of two (Torque driver)
screws.
5) Mount plug assembly. Spanner
Insert hexagon spanner into hexagon hole on the Nominal: Tightening torque:
plug and rotate clockwise to fix the plug. AR20K-B AR20K-B
See Check item for tightening torque of two AR25K-B AR25K-B
screws. AR30K-B AR30K-B
4 0.6±0.05 N・m
AR40K-B AR40K-B
AR50K-B AR50K-B
AR60K-B AR60K-B

7) Check valve assembly


Applicable model Process Procedure Tools Check item
1) Remove the check valve cover.
Disassembly
Rotate two set screws counterclockwise with cross Cross pointed

pointed driver to remove the check valve cover driver
and two set screws.
2) Remove check vavle body assembly from main
body.
- -
AR20K-B At this time, confirm two "O" rings are mounted in
AR25K-B place on the main body.
AR30K-B Assembly 3) Confirm body has ゛O" ring (2pcs). If not, mount
- -
AR40K-B "O" ring.
AR50K-B 4) Insert convex of the check body assembly into two
Orientation of check valve
AR60K-B "O" ring mounting holes on the main body -
body assembly
respectively.
5) Mount the check valve cover.
Rotate two screws clockwise by cross pointed Cross pointed
Tightening torque:
driver to fix check valve cover. driver
0.6±0.05 N・m
See Check item for tightening torque of two (Torque driver)
screws.

12
8. DISASSEMBLY DRAWING
1) AR20K-B/25K-B/30K-B/40K-B/50K-B/60K-B Disassembly drawing
Stem assembly

(Convex)
Mounting screws
③Valve
(4 pcs)
Valve spring

⑤Valve guide assembly


Packing holder
②Bonnet
"O"ring
Adjust screw "O"ring
assembly
Valve guide

Adjust spring

⑭Check valve Cover


(Concave)
assembly ④Diaphragm AR30K-B
Mounting screws (2 pcs) assembly AR40K-B (Detent:4 places)
チェック弁カバー
Check valve cover
AR50K-B
AR60K-B

①Body (Small hole) (Concave)


Cap

Mounting screws (2 pcs)


"O" ring
"O"ring Pressure gauge adaptor
チェック弁本体アセンブリ
Check valve body
assembly ⑪Pressure gauge
adaptor assembly

⑬Plug
⑫Plug assembly

⑮Check valve plug assembly Square embedding type


角形圧力計本体
"O"ring pressure gauge
Mounting screws (2 pcs)
⑪Pressure gauge
adaptor assembly (Screw) (Arrow)
"O" ring ⑨Pressure gauge cover
Pressure gauge adaptor ⑧Square embedding
Mounting screws (2 pcs) type pressure gauge
(Width across flats) ⑩Pressure gauge (Detant insert hole
:2 places) (Detent:2 places)


Note) It is possible to mount Square embedding type pressure gauge or Pressure gauge ⑪
⑫ ⑭
adaptor assembly or Plug assembly instead of Check valve assembly.

13
AR50K-BB / 60K
60K-B Mounting screws
AR20K-B / 25K-B / 30K-B / 40K-B (2 pcs)
Bracket assembly Bracket assembly

Bracket

Bracket assembly


Set nut


Bracket assembly

(Roulette faces)

Bracket
(Concave)
(Roulette faces)
2) AR20K-B/25K-B/30K-B/40K-B/50K-B/60K-B

14
Bracket assembly ・Panel mounting disassembly drawing

(Convex)

Products

Products
9. DIMENSIONS
AR20K-B/25K-B/30K-B/40K-B
Port size
Gauge port size Panel fitting

Note 2
Thickness of plate

AR20K-B 30K-B : MAX.3.5
Bracket
(Option) AR40K-B : MAX.5
Pressure gauge
(Option)

Square embedding
type pressure gauge
(Option)

AR50K-B/60K-B
Port size

Gauge port size

Bracket
(Option)

Pressure gauge
(Option)

Square embedding
type pressure gauge
(Option)

Dimensions
Optional specifications

Model
Round type
Standard specifications Square embedding Round type
pressure gauge
type pressure gauge pressure gauge
(with colour zone)
P1 P2 A B Note1 C D F J K H J H J H J
AR20K-B ・
1/8 1/4 1/8 40 67.4 26.5 28.5 M28X1 28.5 2 Note2 □28 29.5 φ37.5 65 φ37.5 66
AR25K-B ・
1/4 3/8 1/8 53 71.9 28 27.5 M32X1.5 27.5 0 □28 28.5 φ37.5 64 φ37.5 65
AR30K-B ・
1/4 3/8 1/8 53 85.6 30.7 29.4 M38X1.5 29.4 3.5 □28 30.4 φ37.5 65.9 φ37.5 66.9
AR40K-B ・ ・
1/4 3/8 1/2 1/8 70 91.7 35.8 33.8 M42X1.5 33.8 3.5 □28 34.8 φ42.5 71.3 φ42.5 71.3
AR40K-06-B 3/4 1/8 75 93.2 35.8 33.8 M42X1.5 33.8 3 □28 34.8 φ42.5 71.3 φ42.5 71.3
AR50K-B 3/4・1 1/8 90 125 43 43.3 M62X1.5 43.3 3.2 □28 44.3 φ42.5 80.8 φ42.5 80.8
AR60K-B 1 1/8 95 130 46 43.3 M62X1.5 43.3 3.2 □28 44.3 φ42.5 80.8 φ42.5 80.8

Optional specifications
Model Bracket mount dimensions Panel mount dimensions
M N Q R S T U V W Y Z
AR20K-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6
AR25K-B 30 34 43.9 5.4 15.4 55 2.3 25.7 32.5 16 6
AR30K-B 41 40 45.8 6.5 8 53 2.3 31.1 38.5 19 7
AR40K-B 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7
AR40K-06-B 50 54 55.5 8.5 10.5 70 2.3 37 42.5 21 7
AR50K-B 70 66 65.8 11 13 90 3.2 - - - -
AR60K-B 70 66 65.8 11 13 90 3.2 - - - -
Note 1) B dimension is a size in the state to unlock the handle.
Note 2) Pressure gauge mounting position is above piping center for AR20K-B only.

15
S

Revision history

4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN


Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362
URL http://www.smcworld.com

Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2008 SMC Corporation All Rights Reserved

You might also like