Iso 105 B06
Iso 105 B06
Iso 105 B06
INTERNATIONAL ISO
STANDARD 105-B06
Second edition
1998-11-01
A Reference number
ISO 105-B06:1998(E)
Provläsningsexemplar / Preview
ISO 105-B06:1998(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national standards bodies (ISO member bodies). The work of
preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which
a technical committee has been established has the right to be represented
on that committee. International organizations, governmental and non-
governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
This second edition cancels and replaces the first edition (ISO 105-
B06:1992), which has been technically revised.
© ISO 1998
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet iso@iso.ch
Printed in Switzerland
ii
Provläsningsexemplar / Preview
1 Scope
This part of ISO 105 specifies a method for determining the colour fastness and ageing properties of all kinds and
forms of dyed and printed textiles and/or other organic substrates under the action of an artificial light source
representative of natural daylight (D65), and under the simultaneous action of heat. Of the four different sets of
exposure conditions specified (see 6.1), three use D65, and the fourth a somewhat lower cut-off wavelength. The
test method gives special consideration to the light and heat conditions that occur in the interior of a motor vehicle.
The four different sets of conditions specified are known to give similar but not necessarily identical results.
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of
this part of ISO 105. For dated references, subsequent amendments to, or revisions of, any of these publications do
not apply. However, parties to agreements based on this part of ISO 105 are encouraged to investigate the
possibility of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain
registers of currently valid International Standards.
ISO 105-A01:1994, Textiles — Tests for colour fastness — Part A01: General principles of testing.
ISO 105-A02:1993, Textiles — Tests for colour fastness — Part A02: Grey scale for assessing change in colour.
ISO 105-A05:1996, Textiles — Tests for colour fastness — Part A05: Instrumental assessment of change in colour
for determination of grey scale rating.
ISO 105-B02:1994, Textiles — Tests for colour fastness — Part B02: Colour fastness to artificial light: Xenon arc
fading lamp test.
ISO 105-B05:1993, Textiles — Tests for colour fastness — Part B05: Detection and assessment of photochromism.
3 Principle
A specimen to be tested is exposed to artificial light under prescribed conditions, along with a set of blue wool
references. The colour fastness is assessed by comparing the change in colour of the test specimen with that of the
references used, or with the grey scale in accordance with ISO 105-A02, or by means of a colour measuring
instrument in accordance with ISO 105-A05 after the specimen has been exposed to a specified amount of radiant
energy.
1
Provläsningsexemplar / Preview
A specimen to be tested, together with reference 6 (see ISO 105-B02), is exposed to artificial light under prescribed
conditions. The change in colour of the specimen is evaluated on the grey scale in accordance with ISO 105-A02, or
by means of a colour-measuring instrument in accordance with ISO 105-A05. Additional ageing criteria, such as
mechanical properties, may also be evaluated.
NOTE Attention should be paid to the principles for specifying and carrying out the tests, and for evaluating the test results
according to ISO 105-A01.
Two different sets of blue wool references may be used. The two sets of references are not interchangeable.
4.1.1 References 1 to 8
Blue wool references developed and produced in Europe are identified by the numerical designations 1 to 8. These
references are blue wool cloths dyed with the dyes listed in Table 1. They range from 1 (very low colour fastness) to
8 (very high colour fastness) so that each higher-numbered reference is approximately twice as fast as the
preceding one (see Table 1).
Two blue wool references developed and produced in the United States are part of a series of eight references
identified by the letter L followed by the numerical designation. These references are for the purpose of determining
whether the xenon arc apparatus is operating within the desired range concerning set of conditions No. 5 (see D.4).
4.2 Apparatus
The exposure apparatus consists essentially of a climatic test chamber made of a corrosion-resistant material and
containing the optical light source, a filter system and holders for the test specimens.
One or more xenon arc lamps serve as the optical light source. The light for determining the hot light fastness shall
be filtered. Optical light filter systems are used for this purpose. Both absorption filters and combinations of
absorption and reflection filters are used (see annexes B and C). Irrespective of the type of filtration, the conditions
listed in Table 2 on the spectral energy distribution at the surface of the specimen shall be met.
2
Provläsningsexemplar / Preview
The radiant power shall be chosen to ensure that the conditions given in 6.1 are fulfilled.
The irradiance shall not deviate by more than 10 % from the average over the entire area occupied by the
specimens and references.
NOTE Ageing causes the spectral energy distribution and irradiance to change during the service life of the xenon arc lamps
and optical filters. Replacement of the lamps and filters in accordance with the manufacturers' instructions, allows the energy
distribution and irradiance to be maintained. The irradiance can also be adjusted to keep it constant. Manufacturers who supply
an exposure apparatus for use with this part of ISO 105 should ensure that the conditions specified in 4.2 and 6.1 are met.
Since the irradiance at the surface of the specimen is affected by lamp intensity, lamp geometry and the specimen
rack (lamp to specimen distance), repeatability and reproducibility of exposure shall be ensured by a monitoring
radiometer which permits exposure to specified levels of irradiance (incident energy per unit area) at a point in the
plane of the specimen rack (see B.3 and C.3).
The black-standard thermometer shall consist of a plain stainless steel plate, measuring about 70 mm 3 40 mm and
with a thickness of about 0,5 mm, whose temperature is measured by a thermal resistor, with good heat-conducting
properties, fitted to the reverse side. The metal plate is fixed to a plastic plate so that it is thermally insulated. It is
coated with a black layer which has an absorption of at least 95 %, even in the infrared region.
The black-panel thermometer shall consist of a metal plate at least 70 mm 3 150 mm 3 1 mm to which is fastened
a thermal resistor whose sensitive portion is centred both horizontally and vertically on the panel, the entire system
3
Provläsningsexemplar / Preview
being covered with a non-selective, infrared-absorbing black finish. The black finish shall have at least 95 %
absorbance. The side of the panel not facing the light source shall not be thermally insulated.
This shall be of low sulfur content and free from fluorescent brightening agents, or other thin opaque material,
partially covering the specimens and references.
This shall be at least 5 mm thick, with a mass per unit area of 100 g/m2 ± 5 g/m2, for placing under the specimens.
5.1 Test the specimens either with their own backing material or on a layer of polyester nonwoven fabric (see
4.2.8). Unless agreed otherwise, the thickness of the underlying material shall be at least 5 mm. The limit specified
in 5.4 shall be observed. The blue wool references shall be placed on white card that does not contain fluorescent
brightening agents.
5.2 Cut sections of at least 40 mm 3 20 mm from flat materials and if necessary attach them by their narrow edges
to white card that does not contain fluorescent brightening agents. For pile goods, carpets and prints, cut the
sections somewhat larger.
Form loose fibres into a nonwoven fabric or a fibrous web, of uniform thickness and surface and then mount on the
white card.
To facilitate handling, the specimens to be tested and the references may be mounted on one or more cards as
indicated in Figure 1.
5.3 The specimens and references shall be of equal size and shape in order to avoid errors in assessment due to
overrating the visual contrast between exposed and unexposed parts on the larger pattern as against the narrower
references (see 7.1).
5.4 For thick specimens or those with an underlay, the distances from the light source to the surface of the
specimens, the references and the black-standard thermometer or black-panel thermometer shall not differ by more
than about 5 mm.
4
Provläsningsexemplar / Preview
6 Procedure
Four different sets of exposure conditions are permitted in terms of irradiance, black-standard temperature and test-
chamber temperature. The specimens and references are exposed under one of the sets of temperature and
humidity conditions given in Tables 3 and 4.
Set of conditions
Condition
3 1 2
Test chamber 65 ± 3 48 ± 3 45 + 0
25
temperature in °C
a If agreed between the interested parties the test may be run without using humidification unit.
b Broad-band measurement at 300 nm to 400 nm.
c Narrow-band measurement at 420 nm.
5
Provläsningsexemplar / Preview
NOTE The test method set of conditions No. 1 may occasionally give rise to temperatures at the surface of the specimen that
are considerably higher than those encountered in practice. In such cases the method is unsuitable.
Test-chamber temperature, °C 63 ± 2 38 ± 2
Black-panel temperature, °C 89 ± 2 38 ± 2
a Exposure begins at the start of a 3,8 h “light on” period (see annex D).
6.1.1 Fit the exposure cards or specimens into specimen holders and then into the testing apparatus, with all other
specimen holders containing either white cards that are half-covered by an opaque cover with cutout, or exposure
cards.
6.1.2 Carry out exposure under sets of conditions 1, 3 and 5 in the non-turning mode, and that under set no. 2 in
the turning mode. Interrupt exposure only for inspection purposes, in which case remove the specimen holder
concerned from the apparatus.
Fit the testing apparatus with clean xenon arc lamps and clean filters. The light-measuring system shall be
calibrated according to the manufacturer's instructions.
Mount the exposure card with reference 6 (see 4.1.1) in a specimen holder and then in the apparatus, with all other
specimen holders containing white cards that are half-covered by an opaque cover with cutout. Interrupt exposure
only to inspect the exposure card. Continue exposure until a contrast corresponding to rating 3 on the grey scale
(see 4.2.6) is reached on reference 6 (see 4.1.1). By experience radiant exposure of (250 to 300) kJ/m2 at 420 nm
corresponding to (11 to 13,2) MJ/m2 between 300 nm and 400 nm is necessary.
The contrast on reference 6 is best measured colorimetrically with a spectrophotometer. If faded to rating 3 of the
grey scale, it corresponds to a value of 3,4 ± 0,4 DE* (CIELAB) for D65/10°. Before measuring, place the reference
on unexposed card. When performing multiple exposures by method 3, inspect the specimens during the individual
exposure periods, making sure that any deviations from the rated value are compensated during subsequent
exposures, so that the sum of the deviations at the end of the series of exposures does not exceed
± 0,4 DE* (CIELAB). Compensation is achieved by adjusting the exposure time or dose. If agreed between the
interested parties, the exposure may be continued until a contrast corresponding to rating 2 on the gray scale is
reached on reference 6. This means twice the necessary radiant exposure.
Expose the specimen (or group of specimens) and the required references simultaneously under the desired
conditions, in such a manner and for such a time as is necessary to fully evaluate the colour fastness of each
specimen relative to that of the references by progressively covering both the specimens and exposed references
during the test.