Driver Datasheet Ir2112, Inverter Application
Driver Datasheet Ir2112, Inverter Application
Driver Datasheet Ir2112, Inverter Application
026C
IR2112
HIGH AND LOW SIDE DRIVER
Features Product Summary
n Floating channel designed for bootstrap operation
Fully operational to +600V VOFFSET 600V max.
Tolerant to negative transient voltage
dV/dt immune
IO+/- 200 mA / 420 mA
n Gate drive supply range from 10 to 20V
VOUT 10 - 20V
n Undervoltage lockout for both channels
n Separate logic supply range from 5 to 20V ton/off (typ.) 125 & 105 ns
Logic and power ground ±5V offset
n CMOS Schmitt-triggered inputs with pull-down Delay Matching 30 ns
n Cycle by cycle edge-triggered shutdown logic
n Matched propagation delay for both channels Packages
n Outputs in phase with inputs
Description
The IR2112 is a high voltage, high speed power
MOSFET and IGBT driver with independent high and
low side referenced output channels. Proprietary
HVIC and latch immune CMOS technologies enable
ruggedized monolithic construction. Logic inputs are
compatible with standard CMOS or LSTTL outputs.
The output drivers feature a high pulse current buffer
stage designed for minimum driver cross-conduc-
tion. Propagation delays are matched to simplify
use in high frequency applications. The floating
channel can be used to drive an N-channel power
MOSFET or IGBT in the high side configuration
which operates up to 600 volts.
Typical Connection
up to 600V
HO
VDD V DD VB
HIN HIN VS
TO
SD SD LOAD
Parameter Value
Symbol Definition Figure Min. Typ. Max. Units Test Conditions
t on Turn-On Propagation Delay 7 — 125 180 VS = 0V
toff Turn-Off Propagation Delay 8 — 105 160 VS = 600V
t sd Shutdown Propagation Delay 9 — 105 160 V S = 600V
ns
tr Turn-On RiseTime 10 — 80 130
tf Turn-Off Fall Time 11 — 40 65
MT Delay Matching, HS & LS Turn-On/Off — — — 30 Figure 5
Parameter Value
Symbol Definition Figure Min. Typ. Max. Units Test Conditions
VIH Logic “1” Input Voltage 12 9.5 — —
V
VIL Logic “0” Input Voltage 13 — — 6.0
VOH High Level Output Voltage, VBIAS - VO 14 — — 100 IO = 0A
mV
VOL Low Level Output Voltage, VO 15 — — 100 IO = 0A
I LK Offset Supply Leakage Current 16 — — 50 VB = VS = 600V
I QBS Quiescent VBS Supply Current 17 — 25 60 VIN = 0V or VDD
I QCC Quiescent VCC Supply Current 18 — 80 180 VIN = 0V or VDD
µA
I QDD Quiescent VDD Supply Current 19 — 2.0 5.0 VIN = 0V or VDD
I IN+ Logic “1” Input Bias Current 20 — 20 40 VIN = VDD
I IN- Logic “0” Input Bias Current 21 — — 1.0 VIN = 0V
VBSUV+ VBS Supply Undervoltage Positive Going 22 7.4 8.5 9.6
Threshold
VBSUV- VBS Supply Undervoltage Negative Going 23 7.0 8.1 9.2
Threshold
V
VCCUV+ VCC Supply Undervoltage Positive Going 24 7.6 8.6 9.6
Threshold
VCCUV- VCC Supply Undervoltage Negative Going 25 7.2 8.2 9.2
Threshold
I O+ Output High Short Circuit Pulsed Current 26 200 250 — VO = 0V, VIN = VDD
PW ≤ 10 µs
A
I O- Output Low Short Circuit Pulsed Current 27 420 500 — VO = 15V, VIN = 0V
PW ≤ 10 µs
SD
VCC
UV
VDD /VCC DETECT
LIN LEVEL LO
S SHIFT
R Q DELAY
VSS COM
Lead Definitions
Lead
Symbol Description
VDD Logic supply
HIN Logic input for high side gate driver output (HO), in phase
SD Logic input for shutdown
LIN Logic input for low side gate driver output (LO), in phase
V SS Logic ground
VB High side floating supply
HO High side gate drive output
VS High side floating supply return
VCC Low side supply
LO Low side gate drive output
COM Low side return
Lead Assignments
14 Lead DIP 14 Lead DIP w/o Lead 4 16 Lead DIP w/o Leads 4 & 5 16 Lead SOIC (Wide Body)
IR2112 IR2112-1 IR2112-2 IR2112S
Part Number
B-50 CONTROL INTEGRATED C IRCUIT DESIGNERS MANUAL
IR2112
Device Information
Process & Design Rule HVDCMOS 4.0 µm
Transistor Count 220
Die Size 100 X 117 X 26 (mil)
Die Outline
HV = 10 to 600V
IR2112
Figure 1. Input/Output Timing Diagram Figure 2. Floating Supply Voltage Transient Test Circuit
(0 to 600V)
LIN
IR2112 ton tr t off tf
90% 90%
HO
LO 10% 10%
Figure 3. Switching Time Test Circuit Figure 4. Switching Time Waveform Definition
SD
LO HO
50%
10%
t sd
MT MT
HO 90%
90%
LO
LO HO
200 200
Turn-On Delay Time (ns)
50 50
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 7A. Turn-On Time vs. Temperature Figure 7B. Turn-On Time vs. Voltage
250 250
200 200
Turn-Off Delay Time (ns)
150 150
Typ.
100 100
Typ.
50 50
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 8A. Turn-Off Time vs. Temperature Figure 8B. Turn-Off Time vs. Voltage
250 250
200 200
Shutdown Delay Time (ns)
150 150
Typ.
100 100
Typ.
50 50
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 9A. Shutdown Time vs. Temperature Figure 9B. Shutdown Time vs. Voltage
200 200
Turn-On Rise Time (ns)
Typ.
100 100
Typ.
50 50
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 10A. Turn-On Rise Time vs. Temperature Figure 10B. Turn-On Rise Time vs. Voltage
125 125
100 100
Turn-Off Fall Time (ns)
75 75
50 50 Typ.
Typ.
25 25
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 11A. Turn-Off Fall Time vs. Temperature Figure 11B. Turn-Off Fall Time vs. Voltage
15.0 15.0
12.0 12.0
Logic "1" Input Threshold (V)
Min.
9.0 9.0
6.0 6.0
Min.
3.0 3.0
0.0 0.0
-50 -25 0 25 50 75 100 125 5 7.5 10 12.5 15 17.5 20
Temperature (°C) V DD Logic Supply Voltage (V)
Figure 12A. Logic “1” Input Threshold vs. Temperature Figure 12B. Logic “1” Input Threshold vs. Voltage
12.0 12.0
Logic "0" Input Threshold (V)
Max.
6.0 6.0
3.0 3.0
Max.
0.0 0.0
-50 -25 0 25 50 75 100 125 5 7.5 10 12.5 15 17.5 20
Temperature (°C) V DD Logic Supply Voltage (V)
Figure 13A. Logic “0” Input Threshold vs. Temperature Figure 13B. Logic “0” Input Threshold vs. Voltage
1.00 1.00
0.80 0.80
High Level Output Voltage (V)
0.60 0.60
0.40 0.40
0.20 0.20
Max. Max.
0.00 0.00
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 14A. High Level Output vs. Temperature Figure 14B. High Level Output vs. Voltage
1.00 1.00
0.80 0.80
Low Level Output Voltage (V)
0.60 0.60
0.40 0.40
0.20 0.20
Max. Max.
0.00 0.00
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 15A. Low Level Output vs. Temperature Figure 15B. Low Level Output vs. Voltage
400
Offset Supply Leakage Current (µA)
400
200 200
100 100
Max.
Max.
0 0
-50 -25 0 25 50 75 100 125 0 100 200 300 400 500 600
Temperature (°C) V B Boost Voltage (V)
Figure 16A. Offset Supply Current vs. Temperature Figure 16B. Offset Supply Current vs. Voltage
100 100
80 80
V BS Supply Current (µA)
60 60
40 40
20 Typ. 20 Typ.
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) V BS Floating Supply Voltage (V)
Figure 17A. VBS Supply Current vs. Temperature Figure 17B. VBS Supply Current vs. Voltage
250 250
200 200
VCC Supply Current (µA)
150 150
100 100
Typ. Typ.
50 50
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) V CC Fixed Supply Voltage (V)
Figure 18A. VCC Supply Current vs. Temperature Figure 18B. V CC Supply Current vs. Voltage
8.0 8.0
VDD Supply Current (µA)
4.0 4.0
2.0 2.0
Typ. Typ.
0.0 0.0
-50 -25 0 25 50 75 100 125 5 7.5 10 12.5 15 17.5 20
Temperature (°C) VDD Logic Supply Voltage (V)
Figure 19A. VDD Supply Current vs. Temperature Figure 19B. VDD Supply Current vs. Voltage
100 100
80 80
Logic "1" Input Bias Current (µA)
60 60
40 40
20 20
Typ.
T yp.
0 0
-50 -25 0 25 50 75 100 125 5 7.5 10 12.5 15 17.5 20
Temperature (°C) VDD Logic Supply Voltage (V)
Figure 20A. Logic “1” Input Current vs. Temperature Figure 20B. Logic “1” Input Current vs. Voltage
5.00 5.00
4.00 4.00
Logic "0" Input Bias Current (µA)
3.00 3.00
2.00 2.00
Max. Max.
1.00 1.00
0.00 0.00
-50 -25 0 25 50 75 100 125 5 7.5 10 12.5 15 17.5 20
Temperature (°C) VDD Logic Supply Voltage (V)
Figure 21A. Logic “0” Input Current vs. Temperature Figure 21B. Logic “0” Input Current vs. Voltage
10.0 10.0
VBS Undervoltage Lockout + (V)
Typ.
7.0 7.0
6.0 6.0
-50 -25 0 25 50 75 100 125 -50 -25 0 25 50 75 100 125
Temperature (°C) Temperature (°C)
Figure 22. VBS Undervoltage (+) vs. Temperature Figure 23. VBS Undervoltage (-) vs. Temperature
11.0 11.0
10.0 10.0
VCC Undervoltage Lockout + (V)
9.0 9.0
Typ.
Typ.
8.0 8.0
7.0 7.0
6.0 6.0
-50 -25 0 25 50 75 100 125 -50 -25 0 25 50 75 100 125
Temperature (°C) Temperature (°C)
Figure 24. VCC Undervoltage (+) vs. Temperature Figure 25. VCC Undervoltage (-) vs. Temperature
500 500
400 400
Output Source Current (mA)
200 200
Typ.
100 100
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 26A. Output Source Current vs. Temperature Figure 26B. Output Source Current vs. Voltage
Typ.
300 300
150 150
0 0
-50 -25 0 25 50 75 100 125 10 12 14 16 18 20
Temperature (°C) VBIAS Supply Voltage (V)
Figure 27A. Output Sink Current vs. Temperature Figure 27B. Output Sink Current vs. Voltage
150 150
320V
75 75
140V
10V 10V
50 50
25 25
0 0
1E+2 1E+3 1E+4 1E+5 1E+6 1E+2 1E+3 1E+4 1E+5 1E+6
Frequency (Hz) Frequency (Hz)
Figure 28. IR2112 TJ vs. Frequency (IRFBC20) Figure 29. IR2112 TJ vs. Frequency (IRFBC30)
Ω, VCC = 15V
RGATE = 33Ω Ω , VCC = 15V
RGATE = 22Ω
125 125
140V
Junction Temperature (°C)
100 100
10V
75 75
50 50
25 25
0 0
1E+2 1E+3 1E+4 1E+5 1E+6 1E+2 1E+3 1E+4 1E+5 1E+6
Frequency (Hz) Frequency (Hz)
Figure 30. IR2112 TJ vs. Frequency (IRFBC40) Figure 31. IR2112 TJ vs. Frequency (IRFPE50)
Ω, VCC = 15V
RGATE = 15Ω Ω , VCC = 15V
RGATE = 10Ω
CONTROL I NTEGRATED CIRCUIT DESIGNERS MANUAL B-59
IR2112
320V 140V
150 320V 150
125 125
Junction Temperature (°C)
75 10V 75
10V
50 50
25 25
0 0
1E+2 1E+3 1E+4 1E+5 1E+6 1E+2 1E+3 1E+4 1E+5 1E+6
Frequency (Hz) Frequency (Hz)
Figure 32. IR2112S TJ vs. Frequency (IRFBC20) Figure 33. IR2112S TJ vs. Frequency (IRFBC30)
Ω, VCC = 15V
RGATE = 33Ω Ω, VCC = 15V
RGATE = 22Ω
100 100
75 75
50 50
25 25
0 0
1E+2 1E+3 1E+4 1E+5 1E+6 1E+2 1E+3 1E+4 1E+5 1E+6
Frequency (Hz) Frequency (Hz)
Figure 34. IR2112S TJ vs. Frequency (IRFBC40) Figure 35. IR2112S TJ vs. Frequency (IRFPE50)
Ω, VCC = 15V
RGATE = 15Ω Ω, VCC = 15V
RGATE = 10Ω
0.0 20.0
-3.0 16.0
VSS Logic Supply Offset Voltage (V)
VS Offset Supply Voltage (V)
Typ.
-6.0 12.0
-12.0 4.0
-15.0 0.0
10 12 14 16 18 20 10 12 14 16 18 20
V BS Floating Supply Voltage (V) V CC Fixed Supply Voltage (V)
Figure 36. Maximum VS Negative Offset vs. Figure 37. Maximum VSS Positive Offset vs.
VBS Supply Voltage VCC Supply Voltage
B-60 CONTROL INTEGRATED C IRCUIT DESIGNERS MANUAL