UTC LM8560 Mos Ic: Digital Alarm Clock
UTC LM8560 Mos Ic: Digital Alarm Clock
UTC LM8560 Mos Ic: Digital Alarm Clock
DESCRIPTION
The LM8560 is alarm equipped digital clock IC with built-in
driver capable of directly driving LED display equipment. As IC
himself the VDD pin for the LM8560 is graded to withstand a
voltage of 15V.
FEATURES
*Single chip P-channel ED MOS LSI
*LED direct drive using time division (duplex configuration)
*Wide operating power supply voltage range
SDIP-28
*Built-in alarm function with 24-hour control
*Supports changeover between 12-hour AM/PM and 24-hour
displays
*Built-in battery backup CR oscillator
*Users 50Hz or 60Hz as standard frequency
*Built-in automatic fast forward function for hour and minute
settings
*Built-in sleep timer function (maximum intervals of 59 minutes
or 1 hours and 59 minutes)
*Built-in snooze function supporting repeat use
*Equipped with power failure display function
*900Hz output for alarm tone
FUNCTIONS
*Current time display
*Snooze alarm function
*Sleep timer function (maximum intervals of 59 minutes or 1
hours and 59 minutes)
APPLICATIONS
*Alarm clocks
*Clock radios
DESCRIPTION OF OPERATIONS
*50/60Hz Input:
Built-in Shumidt circuit enables noise eliminations at 50/60Hz commercial frequencies with use of a
simple CR filter. Built-in pull-up resistor.
*CR Input:
When the AC power supply is interrupted, the time counter switches to a holding state and a built-in
oscillator promptly begins operation. If 50/60Hz input continues for 3 clocks without arriving, this
oscillator’s output is activated and functions as the time counter clock in place of 50/60Hz input. The
frequency level of this clock oscillator is determined according to the CR value. While the above
mentioned oscillator is operating using backup mode, all segment output is switched to OFF.
(Note) When the backup oscillator is in use due to an AC power supply interruption, the 50/60Hz input
pin must be maintained open or at a VSS level.
*50/60 Selective Input:
When 50/60 selective input is connected to VSS, 50Hz use is enabled. When 50/60 selective input is
left open, VDD is activated using an internal pull-down resistor and the setting is switched to enable use
at 60Hz.
*Display Mode Selective Input (Alarm Select/Sleep Select):
Since the pull-down resistor is built-in , selection from four display modes is possible using two SPST
switches (single-pole and single-throw switches). Table 1 shows these display mode selections.
2Hz
UTC LM8560
PWR UP
7 10'S MIN a&f
PWR UP
AlarmDisplay 19 SEC
T Disp Alarm MIN
Display Alarm HR CTR 8 10'S MIN b&g
CTR Alarm
Control Disp
AL Disp
Sleep Display 23 SL Disp Time&F.Sample
Output Decoder/Driver
Display
Second
UP
Control 11 MIN b&g
Output
Snooze Input 24 12 MIN c&d
Control
13 MIN a&f
20 15 14 18 16 17
VDD VSS Colon Alarm Alarm Sleep
Output OFF Output Output
6
QW-R502-005,D
C1
27k
0.015μ
UTC
f=900Hz
4.7k
R1
27k
110k
2.2k
UTC LM8560
12 HR 60 HZ 2.2k
0.47μ 4.7k
+
0.001μ NC NC
28 27 26 25 24 23 22 21 20 19 18 17 16 15
12/24 CR 50/60 50/60 Snooze Sleep Hour Minute VDD Alarm Alarm Sleep Alarm VSS
Backup HR Input Hz Hz Input Display Set Set Display OFF Output Output
Battery Select Select Input
100k
LM8560
AM&
10'S PM& 10'S 10'S 10'S 10'S 10'S
HR 10'S HR c& HR HR HR MIN MIN MIN MIN e MIN MIN MIN Colon
ag&de HR b HR e b&g c&d a&f a&f b&g c&d &Min e b&g c&d a&f Output
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Duplex
LED
AC a
+ Note: 1 f b
e g c
cycle 1 d
Cathode
2
CLOCK-RADIO APPLICATION CIRCUIT (Positive Power Supply)
Common
cycle 2 This circuit is used as noise interference stripper for
the LW band.(Backup control is enalbled except for
battery backup mode
Unit(resistor:Ω , capacitor : F)
7
QW-R502-005,D
Piezo
Buzzer
UTC
C1 R1 330μ
0.015μ +
UTC LM8560
110k
f=900Hz
0.001μ 12 HR 60 HZ
NC NC
28 27 26 25 24 23 22 21 20 19 18 17 16 15
12/24 CR 50/60 50/60 Snooze Sleep Hour Minute VDD Alarm Alarm Sleep Alarm VSS
HR Input Hz Hz Input Display Set Set Display OFF Output Output
Select Select Input
100k
LM8560
AM& PM& 10'S 10'S 10'S 10'S 10'S
10'S 10'S HR c& HR HR HR MIN MIN MIN MIN e MIN MIN MIN Colon
HR HR b HR e b&g c&d a&f a&f b&g c&d &Min e b&g c&d a&f Output
1 2 3 4 5 6 7 8 9 10 11 12 13 14
CLOCK APPLICATION CIRCUIT (Negative Power Supply)
Duplex
LED
a
AC Note: 1. f b
e g c
cycle 1 d
Cathode
Common
2. When Battery backup or tone output is not
cycle 2
used,CR input is conneced to Vss
8
12 Hour Display and 60Hz Circuit Diagram
QW-R502-005,D
UTC LM8560 MOS IC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.